Sample records for present sensitive high

  1. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

    PubMed Central

    Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.

    2014-01-01

    Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240

  2. Sensitivity Enhancement of FBG-Based Strain Sensor.

    PubMed

    Li, Ruiya; Chen, Yiyang; Tan, Yuegang; Zhou, Zude; Li, Tianliang; Mao, Jian

    2018-05-17

    A novel fiber Bragg grating (FBG)-based strain sensor with a high-sensitivity is presented in this paper. The proposed FBG-based strain sensor enhances sensitivity by pasting the FBG on a substrate with a lever structure. This typical mechanical configuration mechanically amplifies the strain of the FBG to enhance overall sensitivity. As this mechanical configuration has a high stiffness, the proposed sensor can achieve a high resonant frequency and a wide dynamic working range. The sensing principle is presented, and the corresponding theoretical model is derived and validated. Experimental results demonstrate that the developed FBG-based strain sensor achieves an enhanced strain sensitivity of 6.2 pm/με, which is consistent with the theoretical analysis result. The strain sensitivity of the developed sensor is 5.2 times of the strain sensitivity of a bare fiber Bragg grating strain sensor. The dynamic characteristics of this sensor are investigated through the finite element method (FEM) and experimental tests. The developed sensor exhibits an excellent strain-sensitivity-enhancing property in a wide frequency range. The proposed high-sensitivity FBG-based strain sensor can be used for small-amplitude micro-strain measurement in harsh industrial environments.

  3. Sensitivity Enhancement of FBG-Based Strain Sensor

    PubMed Central

    Chen, Yiyang; Tan, Yuegang; Zhou, Zude; Mao, Jian

    2018-01-01

    A novel fiber Bragg grating (FBG)-based strain sensor with a high-sensitivity is presented in this paper. The proposed FBG-based strain sensor enhances sensitivity by pasting the FBG on a substrate with a lever structure. This typical mechanical configuration mechanically amplifies the strain of the FBG to enhance overall sensitivity. As this mechanical configuration has a high stiffness, the proposed sensor can achieve a high resonant frequency and a wide dynamic working range. The sensing principle is presented, and the corresponding theoretical model is derived and validated. Experimental results demonstrate that the developed FBG-based strain sensor achieves an enhanced strain sensitivity of 6.2 pm/με, which is consistent with the theoretical analysis result. The strain sensitivity of the developed sensor is 5.2 times of the strain sensitivity of a bare fiber Bragg grating strain sensor. The dynamic characteristics of this sensor are investigated through the finite element method (FEM) and experimental tests. The developed sensor exhibits an excellent strain-sensitivity-enhancing property in a wide frequency range. The proposed high-sensitivity FBG-based strain sensor can be used for small-amplitude micro-strain measurement in harsh industrial environments. PMID:29772826

  4. A High-Sensitivity Current Sensor Utilizing CrNi Wire and Microfiber Coils

    PubMed Central

    Xie, Xiaodong; Li, Jie; Sun, Li-Peng; Shen, Xiang; Jin, Long; Guan, Bai-ou

    2014-01-01

    We obtain an extremely high current sensitivity by wrapping a section of microfiber on a thin-diameter chromium-nickel wire. Our detected current sensitivity is as high as 220.65 nm/A2 for a structure length of only 35 μm. Such sensitivity is two orders of magnitude higher than the counterparts reported in the literature. Analysis shows that a higher resistivity or/and a thinner diameter of the metal wire may produce higher sensitivity. The effects of varying the structure parameters on sensitivity are discussed. The presented structure has potential for low-current sensing or highly electrically-tunable filtering applications. PMID:24824372

  5. A high-sensitivity current sensor utilizing CrNi wire and microfiber coils.

    PubMed

    Xie, Xiaodong; Li, Jie; Sun, Li-Peng; Shen, Xiang; Jin, Long; Guan, Bai-ou

    2014-05-12

    We obtain an extremely high current sensitivity by wrapping a section of microfiber on a thin-diameter chromium-nickel wire. Our detected current sensitivity is as high as 220.65 nm/A2 for a structure length of only 35 μm. Such sensitivity is two orders of magnitude higher than the counterparts reported in the literature. Analysis shows that a higher resistivity or/and a thinner diameter of the metal wire may produce higher sensitivity. The effects of varying the structure parameters on sensitivity are discussed. The presented structure has potential for low-current sensing or highly electrically-tunable filtering applications.

  6. Development of a highly sensitive immunochromatographic detection kit for H5 influenza virus hemagglutinin using silver amplification.

    PubMed

    Wada, Atsuhiko; Sakoda, Yoshihiro; Oyamada, Takayoshi; Kida, Hiroshi

    2011-12-01

    H5N1, a highly pathogenic avian influenza virus (HPAIV), has become a serious epizootic threat to the poultry population in Asia. In addition, significant numbers of human cases of HPAIV infection have been reported to date. To prevent the spread of HPAIV among humans and to allow for timely medical intervention, a rapid and high sensitive method is needed to detect and subtype the causative HPAIVs. In the present study, a silver amplification technique used in photographic development was combined with immunochromatography technologies and a highly sensitive and rapid diagnostic test to detect the hemagglutinin of H5 influenza viruses was developed. The sensitivity of the test kit was increased 500 times by silver amplification. The sensitivity of the method was more than 10 times higher than those of conventional rapid influenza diagnostic tests, which detect viral nucleoproteins. The diagnostic system developed in the present study can therefore provide rapid and highly sensitive results and will be useful for diagnosis of H5 HPAIV infection in humans and animals. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Combining presentation high-sensitivity cardiac troponin I and glucose measurements to rule-out an acute myocardial infarction in patients presenting to emergency department with chest pain.

    PubMed

    Greenslade, J H; Kavsak, P; Parsonage, W; Shortt, C; Than, M; Pickering, J W; Aldous, S; Cullen, L

    2015-03-01

    The use of high sensitivity troponin (hs-Tn) may enable early rule out of acute myocardial infarction (AMI) for patients presenting to the emergency department (ED) with chest pain. This study evaluated two approaches to the early rule out of AMI; a combination of a presentation hs-Tn <4ng/L and normal glucose at presentation (dual testing) and a presentation hs-Tn troponin below the limit of detection (LoD). We utilised prospectively collected data on adult patients presenting with suspected ACS in two EDs in Australia and New Zealand. Blood samples were taken on presentation and tested for glucose and high sensitivity troponin I. The primary endpoint was index AMI and the secondary endpoint was 30-day acute coronary syndrome (ACS). Sensitivity, specificity, positive and negative predictive values were used to assess the diagnostic accuracy of the dual testing and LoD approaches. Of the 1412 participants, 182 (12.9%) had index AMI. The LoD and the dual testing approach were 100% sensitive for index AMI. The specificity of the dual testing approach (25.2%) was slightly higher than that of the LoD (20.4%). Sensitivity for ACS was similar for the two approaches (96.5% for dual testing and 98.1% for the LoD). The dual testing and LoD approach identified all patients with index AMI and could be used to reduce the proportion of patients requiring lengthy assessment and inpatient admission. Further investigation is still required to rule out unstable angina pectoris in patients identified as low risk. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Punishment Sensitivity Predicts the Impact of Punishment on Cognitive Control

    PubMed Central

    Braem, Senne; Duthoo, Wout; Notebaert, Wim

    2013-01-01

    Cognitive control theories predict enhanced conflict adaptation after punishment. However, no such effect was found in previous work. In the present study, we demonstrate in a flanker task how behavioural adjustments following punishment signals are highly dependent on punishment sensitivity (as measured by the Behavioural Inhibition System (BIS) scale): Whereas low punishment-sensitive participants do show increased conflict adaptation after punishment, high punishment-sensitive participants show no such modulation. Interestingly, participants with a high punishment-sensitivity showed an overall reaction time increase after punishments. Our results stress the role of individual differences in explaining motivational modulations of cognitive control. PMID:24058520

  9. Ultra-long high-sensitivity Φ-OTDR for high spatial resolution intrusion detection of pipelines.

    PubMed

    Peng, Fei; Wu, Han; Jia, Xin-Hong; Rao, Yun-Jiang; Wang, Zi-Nan; Peng, Zheng-Pu

    2014-06-02

    An ultra-long phase-sensitive optical time domain reflectometry (Φ-OTDR) that can achieve high-sensitivity intrusion detection over 131.5km fiber with high spatial resolution of 8m is presented, which is the longest Φ-OTDR reported to date, to the best of our knowledge. It is found that the combination of distributed Raman amplification with heterodyne detection can extend the sensing distance and enhances the sensitivity substantially, leading to the realization of ultra-long Φ-OTDR with high sensitivity and spatial resolution. Furthermore, the feasibility of applying such an ultra-long Φ-OTDR to pipeline security monitoring is demonstrated and the features of intrusion signal can be extracted with improved SNR by using the wavelet detrending/denoising method proposed.

  10. Temperature sensitivity of silicon nitride nanocoated long-period gratings working in various surrounding media

    NASA Astrophysics Data System (ADS)

    Smietana, M.; Bock, W. J.; Mikulic, P.

    2011-11-01

    This paper presents the temperature sensing properties of a silicon nitride (SiNx) nanocoated long-period grating (LPG). A high-temperature, radio-frequency plasma-enhanced chemical-vapor-deposited SiNx nanocoating was applied to tune the external refractive index (RI) sensitivity of LPGs written with UV and electric arc techniques in boron co-doped and standard germanium doped fibers, respectively. The technique allows for deposition of good quality, hard and wear-resistant nanofilms as are required for optical sensors. Thanks to the high-RI SiNx nanocoating, which is less than 90 nm thick, it is possible to reduce RI sensitivity over a wide range (from nD = 1.333 to 1.479), simultaneously decreasing its cross-sensitivity to temperature. For the presented nanocoated LPGs, the temperature effect on resonance wavelength is linear and slightly dependent on the thermo-optic coefficient of the surrounding liquid. The other advantage of the nanocoating is that it makes the resonance clearly visible in the whole investigated external RI range. To the best of our knowledge, this work presents for the first time a nanocoating able to simultaneously tune the RI sensitivity and enable temperature measurements in high-RI liquids applied to LPGs.

  11. Visual sensitivity for luminance and chromatic stimuli during the execution of smooth pursuit and saccadic eye movements.

    PubMed

    Braun, Doris I; Schütz, Alexander C; Gegenfurtner, Karl R

    2017-07-01

    Visual sensitivity is dynamically modulated by eye movements. During saccadic eye movements, sensitivity is reduced selectively for low-spatial frequency luminance stimuli and largely unaffected for high-spatial frequency luminance and chromatic stimuli (Nature 371 (1994), 511-513). During smooth pursuit eye movements, sensitivity for low-spatial frequency luminance stimuli is moderately reduced while sensitivity for chromatic and high-spatial frequency luminance stimuli is even increased (Nature Neuroscience, 11 (2008), 1211-1216). Since these effects are at least partly of different polarity, we investigated the combined effects of saccades and smooth pursuit on visual sensitivity. For the time course of chromatic sensitivity, we found that detection rates increased slightly around pursuit onset. During saccades to static and moving targets, detection rates dropped briefly before the saccade and reached a minimum at saccade onset. This reduction of chromatic sensitivity was present whenever a saccade was executed and it was not modified by subsequent pursuit. We also measured contrast sensitivity for flashed high- and low-spatial frequency luminance and chromatic stimuli during saccades and pursuit. During saccades, the reduction of contrast sensitivity was strongest for low-spatial frequency luminance stimuli (about 90%). However, a significant reduction was also present for chromatic stimuli (about 58%). Chromatic sensitivity was increased during smooth pursuit (about 12%). These results suggest that the modulation of visual sensitivity during saccades and smooth pursuit is more complex than previously assumed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Development of an amorphous selenium based photoconductor and its application in a high-sensitivity photodetector (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Masuzawa, Tomoaki; Ebisudani, Taishi; Ochiai, Jun; Saito, Ichitaro; Yamada, Takatoshi; Chua, Daniel H. C.; Mimura, Hidenori; Okano, Ken

    2016-09-01

    Although present imaging devices are mostly silicon-based devices such as CMOS and CCD, these devices are reaching their sensitivity limit due to the band gap of silicon. Amorphous selenium (a-Se) is a promising candidate for high- sensitivity photo imaging devices, because of its low thermal noise, high spatial resolution, as well as adaptability to wide-area deposition. In addition, internal signal amplification is reported on a-Se based photodetectors, which enables a photodetector having effective quantum efficiency over 100 % against visible light. Since a-Se has sensitivity to UV and soft X-rays, the reported internal signal amplification should be applicable to UV and X-ray detection. However, application of the internal signal amplification required high voltage, which caused unexpected breakdown at the contact or thin-film transistor-based signal read-out. For this reason, vacuum devices having electron-beam read-out is proposed. The advantages of vacuum-type devices are vacuum insulation and its extremely low dark current. In this study, we present recent progresses in developing a-Se based photoconductive films and photodetector using nitrogen-doped diamond electron beam source as signal read-out. A novel electrochemical method is used to dope impurities into a-Se, turning the material from weak p-type to n-type. A p-n junction is formed within a-Se photoconductive film, which has increased the sensitivity of a-Se based photodetector. Our result suggests a possibility of high sensitivity photodetector that can potentially break the limit of silicon-based devices.

  13. Anxiety sensitivity class membership moderates the effects of pre-quit reduction in anxiety sensitivity on quit-day tobacco craving.

    PubMed

    Bakhshaie, Jafar; Zvolensky, Michael J; Langdon, Kirsten J; Leventhal, Adam M; Smits, Jasper A J; Allan, Nicholas; Schmidt, Norman B

    2016-04-01

    Although anxiety sensitivity has been primarily conceptualized as a dimensional latent construct, empirical evidence suggests that it also maintains a latent class structure, reflecting low-, moderate-, and high-risk underlying classes. The present study sought to explore whether these anxiety sensitivity classes moderated the relations between the degree of pre-quit reductions in anxiety sensitivity and the severity of nicotine withdrawal symptoms and craving experienced on quit-day. Participants included 195 adult smokers (47% female; Mage=39.4) participating in a larger "anxiety sensitivity reduction-smoking cessation" intervention trial. Anxiety sensitivity class significantly moderated relations between pre-quit reduction in anxiety sensitivity and quit-day craving. Specifically, smokers within the anxiety sensitivity high-risk class, who also demonstrated lesser pre-quit reductions in anxiety sensitivity, experienced the highest levels of craving on quit-day. These findings highlight the importance of 'high-risk' classes of anxiety sensitivity to better understand the experience of craving on quit day. Copyright © 2016. Published by Elsevier Ltd.

  14. Fabrications and Performance of Wireless LC Pressure Sensors through LTCC Technology.

    PubMed

    Lin, Lin; Ma, Mingsheng; Zhang, Faqiang; Liu, Feng; Liu, Zhifu; Li, Yongxiang

    2018-01-25

    This paper presents a kind of passive wireless pressure sensor comprised of a planar spiral inductor and a cavity parallel plate capacitor fabricated through low-temperature co-fired ceramic (LTCC) technology. The LTCC material with a low Young's modulus of ~65 GPa prepared by our laboratory was used to obtain high sensitivity. A three-step lamination process was applied to construct a high quality cavity structure without using any sacrificial materials. The effects of the thickness of the sensing membranes on the sensitivity and detection range of the pressure sensors were investigated. The sensor with a 148 μm sensing membrane showed the highest sensitivity of 3.76 kHz/kPa, and the sensor with a 432 μm sensing membrane presented a high detection limit of 2660 kPa. The tunable sensitivity and detection limit of the wireless pressure sensors can meet the requirements of different scenes.

  15. A New Kind of Laser Microphone Using High Sensitivity Pulsed Laser Vibrometer

    NASA Technical Reports Server (NTRS)

    Wang, Chen-Chia; Trivedi, Sudhir; Jin, Feng; Swaminathan, V.; Prasad, Narasimha S.

    2008-01-01

    We demonstrate experimentally a new kind of laser microphone using a highly sensitive pulsed laser vibrometer. By using the photo-electromotive-force (photo-EMF) sensors, we present data indicating the real-time detection of surface displacements as small as 4 pm.

  16. Molecular oxygen detection using frequency modulation diode laser spectroscopy

    NASA Technical Reports Server (NTRS)

    Wang, Liang-Guo; Sachse, Glen

    1990-01-01

    A high-sensitivity spectroscopic measurement of O2 using two-tone frequency modulation spectroscopy with a GaAlAs diode laser is presented. An oxygen sensor based on this technique would be non-intrusive, compact and possess high sensitivity and fast time response.

  17. Development of a 300,000-pixel ultrahigh-speed high-sensitivity CCD

    NASA Astrophysics Data System (ADS)

    Ohtake, H.; Hayashida, T.; Kitamura, K.; Arai, T.; Yonai, J.; Tanioka, K.; Maruyama, H.; Etoh, T. Goji; Poggemann, D.; Ruckelshausen, A.; van Kuijk, H.; Bosiers, Jan T.

    2006-02-01

    We are developing an ultrahigh-speed, high-sensitivity broadcast camera that is capable of capturing clear, smooth slow-motion videos even where lighting is limited, such as at professional baseball games played at night. In earlier work, we developed an ultrahigh-speed broadcast color camera1) using three 80,000-pixel ultrahigh-speed, highsensitivity CCDs2). This camera had about ten times the sensitivity of standard high-speed cameras, and enabled an entirely new style of presentation for sports broadcasts and science programs. Most notably, increasing the pixel count is crucially important for applying ultrahigh-speed, high-sensitivity CCDs to HDTV broadcasting. This paper provides a summary of our experimental development aimed at improving the resolution of CCD even further: a new ultrahigh-speed high-sensitivity CCD that increases the pixel count four-fold to 300,000 pixels.

  18. Assessment of Forecast Sensitivity to Observation and Its Application to Satellite Radiances

    NASA Astrophysics Data System (ADS)

    Ide, K.

    2017-12-01

    The Forecast sensitivity to observation provides practical and useful metric for the assessment of observation impact without conducting computationally intensive data denial experiments. Quite often complex data assimilation systems use a simplified version of the forecast sensitivity formulation based on ensembles. In this talk, we first present the comparison of forecast sensitivity for 4DVar, Hybrid-4DEnVar, and 4DEnKF with or without such simplifications using a highly nonlinear model. We then present the results of ensemble forecast sensitivity to satellite radiance observations for Hybrid-4DEnVart using NOAA's Global Forecast System.

  19. Combined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: first experience in an emergency department of a general hospital.

    PubMed

    Lotze, Ulrich; Lemm, Holger; Heyer, Anke; Müller, Karin

    2011-01-01

    The purpose of this observational study was to test the diagnostic performance of the Elecsys® troponin T high-sensitive system combined with copeptin measurement for early exclusion of acute myocardial infarction (MI) in clinical practice. Troponin T high-sensitive (diagnostic cutoff: <14 pg/mL) and copeptin (diagnostic cutoff: <14 pmol/L) levels were determined at admission in addition to other routine laboratory parameters in patients with suspected acute MI presenting to the emergency department of a general hospital over a period of five months. Data from 142 consecutive patients (mean age 71.2 ± 13.5 years, 76 men) were analyzed. Final diagnoses were acute MI in 13 patients (nine ST elevation MI, four non-ST elevation MI, 9.2%) unstable angina pectoris in three (2.1%), cardiac symptoms not primarily associated with myocardial ischemia in 79 (55.6%), and noncardiac disease in 47 patients (33.1%). The patients with acute MI were younger and had higher troponin T high-sensitive and copeptin values than patients without acute MI. Seventeen patients had very high copeptin values (>150 pmol/L), one of whom had a level of >700 pmol/L and died of pulmonary embolism. A troponin T high-sensitive level of <14 pg/mL in combination with copeptin <14 pmol/L at initial presentation ruled out acute MI in 45 of the 142 patients (31.7%), each with a sensitivity and negative predictive value of 100%. According to this early experience, a single determination of troponin T high-sensitive and copeptin may enable early and accurate exclusion of acute MI in one third of patients, even in an emergency department of a general hospital.

  20. A high sensitivity of children to swimming associated gastrointestinal illness (response to letter by Linn)

    EPA Science Inventory

    We disagree with Mr. Linn’s interpretation of our paper, “High Sensitivity of Children to Swimming-Associated Gastrointestinal Illness”.1 His comments are focused on hypothetical interpretation of our results as related to criteria development rather than the science presented. ...

  1. Fluorescence-guided tumor visualization using a custom designed NIR attachment to a surgical microscope for high sensitivity imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kittle, David S.; Patil, Chirag G.; Mamelak, Adam; Hansen, Stacey; Perry, Jeff; Ishak, Laura; Black, Keith L.; Butte, Pramod V.

    2016-03-01

    Current surgical microscopes are limited in sensitivity for NIR fluorescence. Recent developments in tumor markers attached with NIR dyes require newer, more sensitive imaging systems with high resolution to guide surgical resection. We report on a small, single camera solution enabling advanced image processing opportunities previously unavailable for ultra-high sensitivity imaging of these agents. The system captures both visible reflectance and NIR fluorescence at 300 fps while displaying full HD resolution video at 60 fps. The camera head has been designed to easily mount onto the Zeiss Pentero microscope head for seamless integration into surgical procedures.

  2. Genotype-based dosage of acenocoumarol in highly-sensitive geriatric patients.

    PubMed

    Lozano, Roberto; Franco, María-Esther; López, Luis; Moneva, Juan-José; Carrasco, Vicente; Pérez-Layo, Maria-Angeles

    2015-03-01

    Our aim was to determinate the acenocoumarol dose requirement in highly sensitive geriatric patients, based on a minimum of genotype (VKORC1 and CYP2C9) data. We used a Gaussian kernel density estimation test to identify patients highly sensitive to the drug and PHARMACHIP®-Cuma test (Progenika Biopharma, SA, Grifols, Spain) to determine the CYP2C9 and VKORC1 genotype. All highly sensitive geriatric patients were taking ≤5.6 mg/week of acenocoumarol (AC), and 86% of these patients presented the following genotypes: CYP2C9*1/*3 or CYP2C9*1/*2 plus VKORC1 A/G, CYP2C9*3/*3, or VKORC1 A/A. VKORC1 A and CYP2C9*2 and/or *3 allelic variants extremely influence on AC dose requirement of highly sensitive geriatric patients. These patients display acenocoumarol dose requirement of ≤5.6 mg/week.

  3. Highly Sensitive and Reusable Membraneless Field-Effect Transistor (FET)-Type Tungsten Diselenide (WSe2) Biosensors.

    PubMed

    Lee, Hae Won; Kang, Dong-Ho; Cho, Jeong Ho; Lee, Sungjoo; Jun, Dong-Hwan; Park, Jin-Hong

    2018-05-30

    In recent years when the demand for high-performance biosensors has been aroused, a field-effect transistor (FET)-type biosensor (BioFET) has attracted great interest because of its high sensitivity, label-free detection, fast detection speed, and miniaturization. However, the insulating membrane in the conventional BioFET, which is essential in preventing the surface dangling bonds of typical semiconductors from nonspecific bindings, has limited the sensitivity of biosensors. Here, we present a highly sensitive and reusable membraneless BioFET based on a defect-free van der Waals material, tungsten diselenide (WSe 2 ). We intentionally generated a few surface defects that serve as extra binding sites for the bioreceptor immobilization through weak oxygen plasma treatment, consequently magnifying the sensitivity values to 2.87 × 10 5 A/A for 10 mM glucose. The WSe 2 BioFET also maintained its high sensitivity even after several cycles of rinsing and glucose application were repeated.

  4. Nano-textured high sensitivity ion sensitive field effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hajmirzaheydarali, M.; Sadeghipari, M.; Akbari, M.

    2016-02-07

    Nano-textured gate engineered ion sensitive field effect transistors (ISFETs), suitable for high sensitivity pH sensors, have been realized. Utilizing a mask-less deep reactive ion etching results in ultra-fine poly-Si features on the gate of ISFET devices where spacing of the order of 10 nm and less is achieved. Incorporation of these nano-sized features on the gate is responsible for high sensitivities up to 400 mV/pH in contrast to conventional planar structures. The fabrication process for this transistor is inexpensive, and it is fully compatible with standard complementary metal oxide semiconductor fabrication procedure. A theoretical modeling has also been presented to predict themore » extension of the diffuse layer into the electrolyte solution for highly featured structures and to correlate this extension with the high sensitivity of the device. The observed ultra-fine features by means of scanning electron microscopy and transmission electron microscopy tools corroborate the theoretical prediction.« less

  5. Evaluation of a brief aerobic exercise intervention for high anxiety sensitivity.

    PubMed

    Broman-Fulks, Joshua J; Storey, Katelyn M

    2008-04-01

    Anxiety sensitivity, or the belief that anxiety-related sensations can have negative consequences, has been shown to play an important role in the etiology and maintenance of panic disorder and other anxiety-related pathology. Aerobic exercise involves exposure to physiological cues similar to those experienced during anxiety reactions. The present study sought to investigate the efficacy of a brief aerobic exercise intervention for high anxiety sensitivity. Accordingly, 24 participants with high anxiety sensitivity scores (Anxiety Sensitivity Index-Revised scores >28) were randomly assigned to complete either six 20-minute sessions of aerobic exercise or a no-exercise control condition. The results indicated that individuals assigned to the aerobic exercise condition reported significantly less anxiety sensitivity subsequent to exercise, whereas anxiety sensitivity scores among non-exercisers did not significantly change. The clinical research and public health implications of these findings are discussed, and several potential directions for additional research are recommended.

  6. Incorporation of beams into bossed diaphragm for a high sensitivity and overload micro pressure sensor

    NASA Astrophysics Data System (ADS)

    Yu, Zhongliang; Zhao, Yulong; Sun, Lu; Tian, Bian; Jiang, Zhuangde

    2013-01-01

    The paper presents a piezoresistive absolute micro pressure sensor, which is of great benefits for altitude location. In this investigation, the design, fabrication, and test of the sensor are involved. By analyzing the stress distribution of sensitive elements using finite element method, a novel structure through the introduction of sensitive beams into traditional bossed diaphragm is built up. The proposed configuration presents its advantages in terms of high sensitivity and high overload resistance compared with the conventional bossed diaphragm and flat diaphragm structures. Curve fittings of surface stress and deflection based on ANSYS simulation results are performed to establish the equations about the sensor. Nonlinear optimization by MATLAB is carried out to determine the structure dimensions. The output signals in both static and dynamic environments are evaluated. Silicon bulk micromachining technology is utilized to fabricate the sensor prototype, and the fabrication process is discussed. Experimental results demonstrate the sensor features a high sensitivity of 11.098 μV/V/Pa in the operating range of 500 Pa at room temperature, and a high overload resistance of 200 times overpressure to promise its survival under atmosphere. Due to the excellent performance above, the sensor can be applied in measuring the absolute micro pressure lower than 500 Pa.

  7. Give a person power and he or she will show interpersonal sensitivity: the phenomenon and its why and when.

    PubMed

    Schmid Mast, Marianne; Jonas, Klaus; Hall, Judith A

    2009-11-01

    The goal of the present research was to investigate whether high or low power leads to more interpersonal sensitivity and what potentially mediates and moderates this effect. In Study 1, 76 participants in either a high- or low-power position interacted; in Study 2, 134 participants were implicitly primed with either high- or low-power or neutral words; and in Study 3, 96 participants were asked to remember a situation in which they felt high or low power (plus a control condition). In Study 4, 157 participants were told to identify with either an egoistic, empathic, or neutral leadership style. In all studies, interpersonal sensitivity, defined as correctly assessing other people, was then measured using different instruments in each study. Consistently, high power resulted in more interpersonal sensitivity than low power. Feeling respected and proud was partially responsible for this effect. Empathic power as a personality trait was related to more interpersonal sensitivity, and high-power individuals who adopted an empathic instead of an egoistic leadership style were more interpersonally sensitive.

  8. High sensitivity pressure transducer based on the phase characteristics of GMI magnetic sensors

    NASA Astrophysics Data System (ADS)

    Benavides, L. S.; Costa Silva, E.; Costa Monteiro, E.; Hall Barbosa, C. R.

    2018-03-01

    This paper presents a new configuration for a GMI pressure transducer based on the reading of the phase characteristics of GMI sensor, intended for biomedical applications. The development process of this new class of magnetic field transducers is discussed, beginning with the definition of the ideal conditioning of the GMI sensor elements (dc level and frequency of the excitation current and sample length) and continuing with computational simulations of the full electronic circuit performed using the experimental data obtained from measured GMI curves, and have shown that the improvement in the sensitivity of GMI magnetometers is larger when phase-based transducers are used instead of magnitude-based transducers. Parameters of interest of the developed prototype are thoroughly analyzed, such as: sensitivity, linearity and frequency response. Also, the spectral noise density of the developed pressure transducer is evaluated and its resolution in the passband is estimated. A low-cost GMI pressure transducer was developed, presenting high resolution, high sensitivity and a frequency bandwidth compatible to the desired biomedical applications.

  9. Performance Sensitivity Studies on the PIAA Implementation of the High-Contrast Imaging Testbed

    NASA Technical Reports Server (NTRS)

    Sidick, Erkin; Lou, John; Shaklan, Stuart; Levine, Marie

    2010-01-01

    This slide presentation reviews the sensitivity studies on the Phase-Induced Amplitude Apodization (PIAA), or pupil mapping using the High-Contrast Imaging Testbed (HCIT). PIAA is a promising technique in high-dynamic range stellar coronagraph. This presentation reports on the investigation of the effects of the phase and rigid-body errors of various optics on the narrowband contrast performance of the PIAA/HCIT hybrid system. The results have shown that the 2-step wavefront control method utilizing 2-DMs is quite effective in compensating the effects of realistic phase and rigid-body errors of various optics

  10. A wide range and highly sensitive optical fiber pH sensor using polyacrylamide hydrogel

    NASA Astrophysics Data System (ADS)

    Pathak, Akhilesh Kumar; Singh, Vinod Kumar

    2017-12-01

    In the present study we report the fabrication and characterization of no-core fiber sensor (NCFS) using smart hydrogel coating for pH measurement. The no-core fiber (NCF) is stubbed between two single-mode fibers with SMA connector before immobilizing of smart hydrogel. The wavelength interrogation technique is used to calculate the sensitivity of the proposed sensor. The result shows a high sensitivity of 1.94 nm/pH for a wide range of pH values varied from 3 to 10 with a good linear response. In addition to high sensitivity, the fabricated sensor provides a fast response time with a good stability, repeatability and reproducibility.

  11. Atomic magnetometer-based ultra-sensitive magnetic microscopy

    NASA Astrophysics Data System (ADS)

    Kim, Young Jin; Savukov, Igor

    2016-03-01

    An atomic magnetometer (AM) based on lasers and alkali-metal vapor cells is currently the most sensitive non-cryogenic magnetic-field sensor. Many applications in neuroscience and other fields require high resolution, high sensitivity magnetic microscopic measurements. In order to meet this need we combined a cm-size spin-exchange relaxation-free AM with a flux guide (FG) to produce an ultra-sensitive FG-AM magnetic microscope. The FG serves to transmit the target magnetic flux to the AM thus enhancing both the sensitivity and resolution for tiny magnetic objects. In this talk, we will describe a prototype FG-AM device and present experimental and numerical tests of its sensitivity and resolution. We also demonstrate that an optimized FG-AM achieves high resolution and high sensitivity sufficient to detect a magnetic field of a single neuron in a few seconds, which would be an important milestone in neuroscience. We anticipate that this unique device can be applied to the detection of a single neuron, the detection of magnetic nano-particles, which in turn are very important for detection of target molecules in national security and medical diagnostics, and non-destructive testing.

  12. Tailoring force sensitivity and selectivity by microstructure engineering of multidirectional electronic skins

    NASA Astrophysics Data System (ADS)

    Park, Jonghwa; Kim, Jinyoung; Hong, Jaehyung; Lee, Hochan; Lee, Youngoh; Cho, Seungse; Kim, Sung-Woo; Kim, Jae Joon; Kim, Sung Youb; Ko, Hyunhyub

    2018-04-01

    Electronic skins (e-skins) with high sensitivity to multidirectional mechanical stimuli are crucial for healthcare monitoring devices, robotics, and wearable sensors. In this study, we present piezoresistive e-skins with tunable force sensitivity and selectivity to multidirectional forces through the engineered microstructure geometries (i.e., dome, pyramid, and pillar). Depending on the microstructure geometry, distinct variations in contact area and localized stress distribution are observed under different mechanical forces (i.e., normal, shear, stretching, and bending), which critically affect the force sensitivity, selectivity, response/relaxation time, and mechanical stability of e-skins. Microdome structures present the best force sensitivities for normal, tensile, and bending stresses. In particular, microdome structures exhibit extremely high pressure sensitivities over broad pressure ranges (47,062 kPa-1 in the range of <1 kPa, 90,657 kPa-1 in the range of 1-10 kPa, and 30,214 kPa-1 in the range of 10-26 kPa). On the other hand, for shear stress, micropillar structures exhibit the highest sensitivity. As proof-of-concept applications in healthcare monitoring devices, we show that our e-skins can precisely monitor acoustic waves, breathing, and human artery/carotid pulse pressures. Unveiling the relationship between the microstructure geometry of e-skins and their sensing capability would provide a platform for future development of high-performance microstructured e-skins.

  13. Novel fluorescent probe for highly sensitive bioassay using sequential enzyme-linked immunosorbent assay-capillary isoelectric focusing (ELISA-cIEF).

    PubMed

    Henares, Terence G; Uenoyama, Yuta; Nogawa, Yuto; Ikegami, Ken; Citterio, Daniel; Suzuki, Koji; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-06-07

    This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-based signal amplification of ELISA and the concentration of enzyme reaction products by cIEF.

  14. Parental overprotection increases interpersonal sensitivity in healthy subjects.

    PubMed

    Otani, Koichi; Suzuki, Akihito; Matsumoto, Yoshihiko; Kamata, Mitsuhiro

    2009-01-01

    The effect of parental rearing on interpersonal sensitivity was studied in 469 Japanese volunteers. Perceived parental rearing was assessed by the Parental Bonding Instrument, which consists of the factors of care and protection, and interpersonal sensitivity was measured by the Interpersonal Sensitivity Measure (IPSM). In male subjects, higher IPSM scores were related to higher scores of paternal protection (P < .01) and maternal protection (P < .05). In female subjects, higher IPSM scores were related to higher scores of maternal protection (P < .001). The present study suggests that in both males and females, interpersonal sensitivity is increased by high protection of the same-sex parents and that in males there is an additional effect of high maternal protection.

  15. Landscape sensitivity in a dynamic environment

    NASA Astrophysics Data System (ADS)

    Lin, Jiun-Chuan; Jen, Chia-Horn

    2010-05-01

    Landscape sensitivity at different scales and topics is presented in this study. Methodological approach composed most of this paper. According to the environmental records in the south eastern Asia, the environment change is highly related with five factors, such as scale of influence area, background of environment characters, magnitude and frequency of events, thresholds of occurring hazards and influence by time factor. This paper tries to demonstrate above five points from historical and present data. It is found that landscape sensitivity is highly related to the degree of vulnerability of the land and the processes which put on the ground including human activities. The scale of sensitivity and evaluation of sensitivities is demonstrated in this paper by the data around east Asia. The methods of classification are mainly from the analysis of environmental data and the records of hazards. From the trend of rainfall records, rainfall intensity and change of temperature, the magnitude and frequency of earthquake, dust storm, days of draught, number of hazards, there are many coincidence on these factors with landscape sensitivities. In conclusion, the landscape sensitivities could be classified as four groups: physical stable, physical unstable, unstable, extremely unstable. This paper explain the difference.

  16. Epi-Fluorescence Microscopy

    PubMed Central

    Webb, Donna J.; Brown, Claire M.

    2012-01-01

    Epi-fluorescence microscopy is available in most life sciences research laboratories, and when optimized can be a central laboratory tool. In this chapter, the epi-fluorescence light path is introduced and the various components are discussed in detail. Recommendations are made for incident lamp light sources, excitation and emission filters, dichroic mirrors, objective lenses, and charge-coupled device (CCD) cameras in order to obtain the most sensitive epi-fluorescence microscope. The even illumination of metal-halide lamps combined with new “hard” coated filters and mirrors, a high resolution monochrome CCD camera, and a high NA objective lens are all recommended for high resolution and high sensitivity fluorescence imaging. Recommendations are also made for multicolor imaging with the use of monochrome cameras, motorized filter turrets, individual filter cubes, and corresponding dyes that are the best choice for sensitive, high resolution multicolor imaging. Images should be collected using Nyquist sampling and should be corrected for background intensity contributions and nonuniform illumination across the field of view. Photostable fluorescent probes and proteins that absorb a lot of light (i.e., high extinction co-efficients) and generate a lot of fluorescence signal (i.e., high quantum yields) are optimal. A neuronal immune-fluorescence labeling protocol is also presented. Finally, in order to maximize the utility of sensitive wide-field microscopes and generate the highest resolution images with high signal-to-noise, advice for combining wide-field epi-fluorescence imaging with restorative image deconvolution is presented. PMID:23026996

  17. Changes in CR-39 proton sensitivity due to prolonged exposure to high vacuums relevant to the National Ignition Facility and OMEGA.

    PubMed

    Manuel, M J-E; Rosenberg, M J; Sinenian, N; Rinderknecht, H; Zylstra, A B; Séguin, F H; Frenje, J; Li, C K; Petrasso, R D

    2011-09-01

    When used at facilities like OMEGA and the NIF, CR-39 is exposed to high vacuum environments before and after irradiation by charged particles and neutrons. Using an electrostatic linear accelerator at MIT, studies have been conducted to investigate the effects of high vacuum exposure on the sensitivity of CR-39 to fusion protons in the ~1-9 MeV energy range. High vacuum conditions, of order 10(-5) Torr, experienced by CR-39 samples at these facilities were emulated. It is shown that vacuum exposure times longer than ~16 h before proton irradiation result in a decrease in proton sensitivity, whereas no effect was observed for up to 67 h of vacuum exposure after proton irradiation. CR-39 sensitivity curves are presented for samples with prolonged exposure to high vacuum before and after proton irradiation. © 2011 American Institute of Physics

  18. Dimension scaling effects on the yield sensitivity of HEMT digital circuits

    NASA Technical Reports Server (NTRS)

    Sarker, Jogendra C.; Purviance, John E.

    1992-01-01

    In our previous works, using a graphical tool, yield factor histograms, we studied the yield sensitivity of High Electron Mobility Transistors (HEMT) and HEMT circuit performance with the variation of process parameters. This work studies the scaling effects of process parameters on yield sensitivity of HEMT digital circuits. The results from two HEMT circuits are presented.

  19. The application of sensitivity analysis to models of large scale physiological systems

    NASA Technical Reports Server (NTRS)

    Leonard, J. I.

    1974-01-01

    A survey of the literature of sensitivity analysis as it applies to biological systems is reported as well as a brief development of sensitivity theory. A simple population model and a more complex thermoregulatory model illustrate the investigatory techniques and interpretation of parameter sensitivity analysis. The role of sensitivity analysis in validating and verifying models, and in identifying relative parameter influence in estimating errors in model behavior due to uncertainty in input data is presented. This analysis is valuable to the simulationist and the experimentalist in allocating resources for data collection. A method for reducing highly complex, nonlinear models to simple linear algebraic models that could be useful for making rapid, first order calculations of system behavior is presented.

  20. High Electrochemical Sensitivity of TiO2- x Nanosheets and an Electron-Induced Mutual Interference Effect toward Heavy Metal Ions Demonstrated Using X-ray Absorption Fine Structure Spectra.

    PubMed

    Zhou, Wen-Yi; Li, Shan-Shan; Song, Jie-Yao; Jiang, Min; Jiang, Tian-Jia; Liu, Jin-Yun; Liu, Jin-Huai; Huang, Xing-Jiu

    2018-04-03

    Mutual interference is a severe issue that occurs during the electrochemical detection of heavy metal ions. This limitation presents a notable drawback for its high sensitivity to specific targets. Here, we present a high electrochemical sensitivity of ∼237.1 μA cm -2 μM -1 toward copper(II) [Cu(II)] based on oxygen-deficient titanium dioxide (TiO 2- x ) nanosheets. We fully demonstrated an atomic-level relationship between electrochemical behaviors and the key factors, including the high-energy (001) facet percentage, oxygen vacancy concentration, surface -OH content, and charge carrier density, is fully demonstrated. These four factors were quantified using Raman, electron spin resonance, X-ray photoelectron spectroscopy spectra, and Mott-Schottky plots. In the mutual interference investigation, we selected cadmium(II) [Cd(II)] as the target ion because of the significant difference in its stripping potential (∼700 mV). The results show that the Cd(II) can enhance the sensitivity of TiO 2- x nanosheets toward Cu(II), exhibiting an electron-induced mutual interference effect, as demonstrated by X-ray absorption fine structure spectra.

  1. Intersatellite communications optoelectronics research at the Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Krainak, Michael A.

    1992-01-01

    A review is presented of current optoelectronics research and development at the NASA Goddard Space Flight Center for high-power, high-bandwidth laser transmitters; high-bandwidth, high-sensitivity optical receivers; pointing, acquisition, and tracking components; and experimental and theoretical system modeling at the NASA Goddard Space Flight Center. Program hardware and space flight opportunities are presented.

  2. Comb-referenced ultra-high sensitivity spectroscopic molecular detection by compact non-linear sources

    NASA Astrophysics Data System (ADS)

    Cancio, P.; Gagliardi, G.; Galli, I.; Giusfredi, G.; Maddaloni, P.; Malara, P.; Mazzotti, D.; De Natale, P.

    2017-11-01

    We present a new generation of compact and rugged mid-infrared (MIR) difference-frequency coherent radiation sources referenced to fiber-based optical frequency comb synthesizers (OFCSs). By coupling the MIR radiation to high-finesse optical cavities, high-resolution and high-sensitivity spectroscopy is demonstrated for CH4 and CO2 around 3.3 and 4.5 μm respectively. Finally, the most effective detection schemes for space-craft trace-gas monitoring applications are singled out.

  3. Glycan-functionalized graphene-FETs toward selective detection of human-infectious avian influenza virus

    NASA Astrophysics Data System (ADS)

    Ono, Takao; Oe, Takeshi; Kanai, Yasushi; Ikuta, Takashi; Ohno, Yasuhide; Maehashi, Kenzo; Inoue, Koichi; Watanabe, Yohei; Nakakita, Shin-ichi; Suzuki, Yasuo; Kawahara, Toshio; Matsumoto, Kazuhiko

    2017-03-01

    There are global concerns about threat of pandemic caused by the human-infectious avian influenza virus. To prevent the oncoming pandemic, it is crucial to analyze the viral affinity to human-type or avian-type sialoglycans with high sensitivity at high speed. Graphene-FET (G-FET) realizes such high-sensitive electrical detection of the targets, owing to graphene’s high carrier mobility. In the present study, G-FET was functionalized using sialoglycans and employed for the selective detection of lectins from Sambucus sieboldiana and Maackia amurensis as alternatives of the human and avian influenza viruses. Glycan-functionalized G-FET selectively monitored the sialoglycan-specific binding reactions at subnanomolar sensitivity.

  4. Reflective type objective based spectral-domain phase-sensitive optical coherence tomography for high-sensitive structural and functional imaging of cochlear microstructures through intact bone of an excised guinea pig cochlea

    NASA Astrophysics Data System (ADS)

    Subhash, Hrebesh M.; Wang, Ruikang K.; Chen, Fangyi; Nuttall, Alfred L.

    2013-03-01

    Most of the optical coherence tomographic (OCT) systems for high resolution imaging of biological specimens are based on refractive type microscope objectives, which are optimized for specific wave length of the optical source. In this study, we present the feasibility of using commercially available reflective type objective for high sensitive and high resolution structural and functional imaging of cochlear microstructures of an excised guinea pig through intact temporal bone. Unlike conventional refractive type microscopic objective, reflective objective are free from chromatic aberrations due to their all-reflecting nature and can support a broadband of spectrum with very high light collection efficiency.

  5. Assessing sensitivity and specificity of the Manchester Triage System in the evaluation of acute coronary syndrome in adult patients in emergency care: a systematic review.

    PubMed

    Nishi, Fernanda Ayache; de Oliveira Motta Maia, Flávia; de Souza Santos, Itamar; de Almeida Lopes Monteiro da Cruz, Dina

    2017-06-01

    Triage is the first assessment and sorting process used to prioritize patients arriving in the emergency department (ED). As a triage tool, the Manchester Triage System (MTS) must have a high sensitivity to minimize the occurrence of under-triage, but must not compromise specificity to avoid the occurrence of overtriage. Sensitivity and specificity of the MTS can be calculated using the frequency of appropriately assigned clinical priority levels for patients presenting to the ED. However, although there are well established criteria for the prioritization of patients with suspected acute coronary syndrome (ACS), several studies have reported difficulties when evaluating patients with this condition. The objective of this review was to synthesize the best available evidence on assessing the sensitivity and specificity of the MTS for screening high-level priority adult patients presenting to the ED with ACS. The current review considered studies that evaluated the use of the MTS in the risk classification of adult patients in the ED. In this review, studies that investigated the priority level, as established by the MTS to screen patients under suspicion of ACS or the sensitivity and specificity of the MTS, for screening patients before the medical diagnosis of ACS were included. This review included both experimental and epidemiological study designs. The results were presented in a narrative synthesis. Six studies were appraised by the independent reviewers. All appraised studies enrolled a consecutive or random sample of patients and presented an overall moderate methodological quality, and all of them were included in this review. A total of 54,176 participants were included in the six studies. All studies were retrospective. Studies included in this review varied in content and data reporting. Only two studies reported sensitivity and specificity values or all the necessary data to calculate sensitivity and specificity. The remaining four studies presented either a sensitivity analysis or the number of true positives and false negatives. However, these four studies were conducted considering only data from patients diagnosed with ACS. Sensitivity values were relatively uniform among the studies: 0.70-0.80. A specificity of 0.59 was reported in the study including only patients with non-traumatic chest pain. On the other hand, in the study that included patients with any complaint, the specificity of MTS to screen patients with ACS was 0.97. The current review demonstrates that the MTS has a moderate sensitivity to evaluate patients with ACS. This may compromise time to treatment in the ED, an important variable in the prognosis of ACS. Atypical presentation of ACS, or high specificity, may also explain the moderate sensitivity demonstrated in this review. However, because of minimal data, it is not possible to confirm this hypothesis. It is difficult to determine the acceptable level of sensitivity or specificity to ensure that a certain triage system is safe.

  6. Effects of periodontal therapy on C-reactive protein and HDL in serum of subjects with periodontitis.

    PubMed

    Leite, Anne Carolina Eleutério; Carneiro, Valéria Martins de Araújo; Guimarães, Maria do Carmo Machado

    2014-01-01

    To investigate the effects of nonsurgical periodontal therapy on levels of high-sensitivity C-reactive protein in the sera and its association with body mass index and high density lipoprotein in subjects with severe periodontitis. Sera from 28 subjects (mean age: 34.36±6.24; 32% men) with severe periodontitis and 27 healthy controls (mean age: 33.18±6.42; 33% men) were collected prior to periodontal therapy. Blood samples were obtained from 23 subjects who completed therapy (9-12 months). Oral and systemic parameters such as the number of blood cells, glucose examination, lipid profile, and high-sensitivity C-reactive protein levels accessed by high-sensitivity immunonephelometry assay, were included. Before therapy, in the periodontitis group, the ratio of subjects with high-sensitivity C-reactive protein <0.3 mg/dL was statistically lower than in the control group (P<0.0216). After therapy, the ratio of subjects with high-sensitivity C-reactive protein <0.3 mg/dL was significantly higher (65.22%) (P<0.0339). The mean value for body mass index was statistically lower in subjects with high-sensitivity C-reactive protein <0.3 mg/dL (24.63±4.19), compared with those with high-sensitivity C-reactive protein >0.3 mg/dL (28.91±6.03) (P<0.0411). High density lipoprotein presented a mean value statistically higher after therapy (P<0.0027). In systemically healthy subjects with periodontitis, periodontal therapy was associated with decreased levels of circulating high-sensitivity C-reactive protein and increase of high density lipoprotein in serum. The clinical trial was registered at http://www.clinicaltrials.gov.br/, No. RBR-24T799.

  7. The effects of physiological arousal on cognitive and psychomotor performance among individuals with high and low anxiety sensitivity.

    PubMed

    Barnard, Kirsten E; Broman-Fulks, Joshua J; Michael, Kurt D; Webb, Rosemary M; Zawilinski, Laci L

    2011-03-01

    Information-processing models of anxiety posit that anxiety pathology is associated with processing biases that consume cognitive resources and may detract from one's ability to process environmental stimuli. Previous research has consistently indicated that high anxiety has a negative impact on cognitive and psychomotor performance. Anxiety sensitivity, or the fear of anxiety and anxiety-related arousal sensations, is an anxiety vulnerability factor that has been shown to play a role in the development and maintenance of panic attacks and panic disorder. However, relatively little is known regarding the potential impact of anxiety sensitivity on performance. In the present study, 105 college students who scored either high (≥ 24) or low (≤ 14) on the Anxiety Sensitivity Index were randomly assigned to complete a series of arousal-induction tasks or no activity, followed immediately by three cognitive and psychomotor performance tasks: digit span - backward, math fluency, and grooved pegboard. Results indicated that participants with high anxiety sensitivity performed comparably to individuals with low anxiety sensitivity on each task, regardless of arousal level.

  8. Probing the SEB Sensitive Depth of a Power MOSFET Using a Two-Photon Absorption Laser Method

    NASA Technical Reports Server (NTRS)

    Lauenstein, Jean-Marie; Liu, Sandra; Titus, Jeffrey L.; McMorrow, Dale; Casey, Megan C.; Buchner, Stephen P.; Warner, Jeffrey; Phan, Anthony M.; Topper, Alyson D.; Kim, Hak S.; hide

    2011-01-01

    This paper presents two-photon absorption test results on an engineering single-event burnout- (SEB-) sensitive power MOSFET to verify that the energy deposition/charge ionization in the highly-doped substrate does not contribute to SEB. It is shown that for a vertical power MOSFET, the SEB sensitive volume is the lightly doped epitaxial layer; the most sensitive region is under the polysllicon gate.

  9. Identification of mission sensitivities for high-power electric propulsion systems

    NASA Technical Reports Server (NTRS)

    Frisbee, Robert H.; Moeller, Robert C.

    2005-01-01

    This paper presents the results of mission analyses that expose various mission performance sensitivities and system advantages of the ALFA technology for a small but representative subset of nuclear electric propulsion (NEP) missions considered under NASA's Project Prometheus.

  10. Finding the bottom and using it

    PubMed Central

    Sandoval, Ruben M.; Wang, Exing; Molitoris, Bruce A.

    2014-01-01

    Maximizing 2-photon parameters used in acquiring images for quantitative intravital microscopy, especially when high sensitivity is required, remains an open area of investigation. Here we present data on correctly setting the black level of the photomultiplier tube amplifier by adjusting the offset to allow for accurate quantitation of low intensity processes. When the black level is set too high some low intensity pixel values become zero and a nonlinear degradation in sensitivity occurs rendering otherwise quantifiable low intensity values virtually undetectable. Initial studies using a series of increasing offsets for a sequence of concentrations of fluorescent albumin in vitro revealed a loss of sensitivity for higher offsets at lower albumin concentrations. A similar decrease in sensitivity, and therefore the ability to correctly determine the glomerular permeability coefficient of albumin, occurred in vivo at higher offset. Finding the offset that yields accurate and linear data are essential for quantitative analysis when high sensitivity is required. PMID:25313346

  11. Highly sensitive detection of dipicolinic acid with a water-dispersible terbium-metal organic framework.

    PubMed

    Bhardwaj, Neha; Bhardwaj, Sanjeev; Mehta, Jyotsana; Kim, Ki-Hyun; Deep, Akash

    2016-12-15

    The sensitive detection of dipicolinic acid (DPA) is strongly associated with the sensing of bacterial organisms in food and many types of environmental samples. To date, the demand for a sensitive detection method for bacterial toxicity has increased remarkably. Herein, we investigated the DPA detection potential of a water-dispersible terbium-metal organic framework (Tb-MOF) based on the fluorescence quenching mechanism. The Tb-MOF showed a highly sensitive ability to detect DPA at a limit of detection of 0.04nM (linear range of detection: 1nM to 5µM) and also offered enhanced selectivity from other commonly associated organic molecules. The present study provides a basis for the application of Tb-MOF for direct, convenient, highly sensitive, and specific detection of DPA in the actual samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Sensitivity analysis of Jacobian determinant used in treatment planning for lung cancer

    NASA Astrophysics Data System (ADS)

    Shao, Wei; Gerard, Sarah E.; Pan, Yue; Patton, Taylor J.; Reinhardt, Joseph M.; Durumeric, Oguz C.; Bayouth, John E.; Christensen, Gary E.

    2018-03-01

    Four-dimensional computed tomography (4DCT) is regularly used to visualize tumor motion in radiation therapy for lung cancer. These 4DCT images can be analyzed to estimate local ventilation by finding a dense correspondence map between the end inhalation and the end exhalation CT image volumes using deformable image registration. Lung regions with ventilation values above a threshold are labeled as regions of high pulmonary function and are avoided when possible in the radiation plan. This paper investigates a sensitivity analysis of the relative Jacobian error to small registration errors. We present a linear approximation of the relative Jacobian error. Next, we give a formula for the sensitivity of the relative Jacobian error with respect to the Jacobian of perturbation displacement field. Preliminary sensitivity analysis results are presented using 4DCT scans from 10 individuals. For each subject, we generated 6400 random smooth biologically plausible perturbation vector fields using a cubic B-spline model. We showed that the correlation between the Jacobian determinant and the Frobenius norm of the sensitivity matrix is close to -1, which implies that the relative Jacobian error in high-functional regions is less sensitive to noise. We also showed that small displacement errors on the average of 0.53 mm may lead to a 10% relative change in Jacobian determinant. We finally showed that the average relative Jacobian error and the sensitivity of the system for all subjects are positively correlated (close to +1), i.e. regions with high sensitivity has more error in Jacobian determinant on average.

  13. High fat diet and food restriction differentially modify the behavioral effects of quinpirole and raclopride in rats.

    PubMed

    Baladi, Michelle G; France, Charles P

    2009-05-21

    Nutritional status can impact dopamine systems in a manner that might be important to understanding possible common neurobiological mechanisms that mediate abnormal compulsive food (e.g., obesity) and drug taking. Limiting food intake, for example, can increase sensitivity to the behavioral effects of indirect-acting dopamine receptor agonists. Much less is known regarding possible diet-induced changes in sensitivity to direct-acting dopamine receptor drugs. The present study investigated the effects of a high fat diet and of food restriction on sensitivity of rats to the behavioral effects of a direct-acting dopamine receptor agonist and a dopamine receptor antagonist. Free access to high fat chow increased sensitivity to quinpirole-induced yawning without changing sensitivity to raclopride-induced catalepsy or quinpirole-induced hypothermia. Food restriction (10 g/day) decreased sensitivity to quinpirole-induced yawning and raclopride-induced catalepsy without affecting sensitivity to quinpirole-induced hypothermia. Free access to a standard chow restored sensitivity to the behavioral effects of both drugs in rats that were previously food-restricted but not in rats that previously ate a high fat diet. These data confirm that food restriction can decrease sensitivity to behavioral effects of direct-acting dopamine receptor drugs, they provide evidence (i.e., no change in hypothermic effects) indicating that these changes are not due to pharmacokinetic mechanisms, and they provide initial evidence showing enhanced sensitivity to behavioral effects of dopamine receptor drugs in rats eating a high fat diet. These changes in sensitivity of dopamine systems could be relevant to understanding the impact of nutrition on therapeutic and recreational drug use.

  14. High fat diet and food restriction differentially modify the behavioral effects of quinpirole and raclopride in rats

    PubMed Central

    Baladi, Michelle G; France, Charles P

    2009-01-01

    Nutritional status can impact dopamine systems in a manner that might be important to understanding possible common neurobiological mechanisms that mediate abnormal compulsive food (e.g., obesity) and drug taking. Limiting food intake, for example, can increase sensitivity to the behavioral effects of indirect-acting dopamine receptor agonists. Much less is known regarding possible diet-induced changes in sensitivity to direct-acting dopamine receptor drugs. The present study investigated the effects of a high fat diet and of food restriction on sensitivity of rats to the behavioral effects of a direct-acting dopamine receptor agonist and a dopamine receptor antagonist. Free access to high fat chow increased sensitivity to quinpirole-induced yawning without changing sensitivity to raclopride-induced catalepsy or quinpirole-induced hypothermia. Food restriction (10 g/day) decreased sensitivity to quinpirole-induced yawning and raclopride-induced catalepsy without affecting sensitivity to quinpirole-induced hypothermia. Free access to a standard chow restored sensitivity to the behavioral effects of both drugs in rats that were previously food-restricted but not in rats that previously ate a high fat diet. These data confirm that food restriction can decrease sensitivity to behavioral effects of direct-acting dopamine receptor drugs, they provide evidence (i.e., no change in hypothermic effects) indicating that these changes are not due to pharmacokinetic mechanisms, and they provide initial evidence showing enhanced sensitivity to behavioral effects of dopamine receptor drugs in rats eating a high fat diet. These changes in sensitivity of dopamine systems could be relevant to understanding the impact of nutrition on therapeutic and recreational drug use. PMID:19327348

  15. Ultra-sensitive magnetic microscopy with an atomic magnetometer and flux guides

    NASA Astrophysics Data System (ADS)

    Kim, Young Jin; Savukov, Igor

    Many applications in neuroscience, biomedical research, and material science require high-sensitivity, high-resolution magnetometry. In order to meet this need we recently combined a cm-size spin-exchange relaxation-free Atomic Magnetometer (AM) with a flux guide (FG) to produce ultra-sensitive FG-AM magnetic microscopy. The FG serves to transmit the target magnetic flux to the AM thus enhancing both the sensitivity and resolution to tiny magnetic objects. In this talk, we will describe existing and next generation FG-AM devices and present experimental and numerical tests of its sensitivity and resolution. We demonstrate that an optimized FG-AM has sufficient resolution and sensitivity for the detection of a small number of neurons, which would be an important milestone in neuroscience. In addition, as a demonstration of one possible application of the FG-AM device, we conducted high-resolution magnetic imaging of micron-size magnetic particles. We will show that the device can produce clear microscopic magnetic image of 10 μm-size magnetic particles.

  16. Novel designs for application specific MEMS pressure sensors.

    PubMed

    Fragiacomo, Giulio; Reck, Kasper; Lorenzen, Lasse; Thomsen, Erik V

    2010-01-01

    In the framework of developing innovative microfabricated pressure sensors, we present here three designs based on different readout principles, each one tailored for a specific application. A touch mode capacitive pressure sensor with high sensitivity (14 pF/bar), low temperature dependence and high capacitive output signal (more than 100 pF) is depicted. An optical pressure sensor intrinsically immune to electromagnetic interference, with large pressure range (0-350 bar) and a sensitivity of 1 pm/bar is presented. Finally, a resonating wireless pressure sensor power source free with a sensitivity of 650 KHz/mmHg is described. These sensors will be related with their applications in harsh environment, distributed systems and medical environment, respectively. For many aspects, commercially available sensors, which in vast majority are piezoresistive, are not suited for the applications proposed.

  17. Etched Polymer Fibre Bragg Gratings and Their Biomedical Sensing Applications

    PubMed Central

    Rajan, Ginu; Bhowmik, Kishore; Xi, Jiangtao; Peng, Gang-Ding

    2017-01-01

    Bragg gratings in etched polymer fibres and their unique properties and characteristics are discussed in this paper. Due to the change in material and mechanical properties of the polymer fibre through etching, Bragg gratings inscribed in such fibres show high reflectivity and enhanced intrinsic sensitivity towards strain, temperature, and pressure. The short-term and long-term stability of the gratings and the effect of hysteresis on the dynamic characteristics are also discussed. The unique properties and enhanced intrinsic sensitivity of etched polymer fibre Bragg grating are ideal for the development of high-sensitivity sensors for biomedical applications. To demonstrate their biomedical sensing capabilities, a high-sensitivity pressure transducer that operates in the blood pressure range, and a breathing rate monitoring device are developed and presented. PMID:29027945

  18. Deep-UV-sensitive high-frame-rate backside-illuminated CCD camera developments

    NASA Astrophysics Data System (ADS)

    Dawson, Robin M.; Andreas, Robert; Andrews, James T.; Bhaskaran, Mahalingham; Farkas, Robert; Furst, David; Gershstein, Sergey; Grygon, Mark S.; Levine, Peter A.; Meray, Grazyna M.; O'Neal, Michael; Perna, Steve N.; Proefrock, Donald; Reale, Michael; Soydan, Ramazan; Sudol, Thomas M.; Swain, Pradyumna K.; Tower, John R.; Zanzucchi, Pete

    2002-04-01

    New applications for ultra-violet imaging are emerging in the fields of drug discovery and industrial inspection. High throughput is critical for these applications where millions of drug combinations are analyzed in secondary screenings or high rate inspection of small feature sizes over large areas is required. Sarnoff demonstrated in1990 a back illuminated, 1024 X 1024, 18 um pixel, split-frame-transfer device running at > 150 frames per second with high sensitivity in the visible spectrum. Sarnoff designed, fabricated and delivered cameras based on these CCDs and is now extending this technology to devices with higher pixel counts and higher frame rates through CCD architectural enhancements. The high sensitivities obtained in the visible spectrum are being pushed into the deep UV to support these new medical and industrial inspection applications. Sarnoff has achieved measured quantum efficiencies > 55% at 193 nm, rising to 65% at 300 nm, and remaining almost constant out to 750 nm. Optimization of the sensitivity is being pursued to tailor the quantum efficiency for particular wavelengths. Characteristics of these high frame rate CCDs and cameras will be described and results will be presented demonstrating high UV sensitivity down to 150 nm.

  19. Sensory Processing Sensitivity: Factors of the Highly Sensitive Person Scale and Their relationships to Personality and Subjective Health Complaints.

    PubMed

    Listou Grimen, Hanne; Diseth, Åge

    2016-12-01

    The aim of the present study was to examine the factor structure of a Norwegian version of the Highly Sensitive Person Scale (HSPS) and to investigate how sensory processing sensitivity (SPS) is related to personality traits of neuroticism, extraversion, and openness and to subjective health complaints (SHC) in a sample of 167 undergraduate psychology students. The results showed that the variance in a shortened version of the HSPS was best described by three separate factors: ease of excitation (EOE), aesthetic sensitivity (AES), and low sensory threshold (LST). Furthermore, the result showed than an overall SPS factor (EOE, LST, and AES combined) was predicted positively by neuroticism and openness and negatively by extraversion. With respect to SHC, the results showed that EOE and LST were positively associated with psychological health complaints. However, the personality trait of neuroticism contributed more than the SPS factors as predictor of SHC. In conclusion, the present study supported a shortened version of the HSPS and its relation to personality factors and SHC. © The Author(s) 2016.

  20. A low-cost photonic biosensor built on a polymer platform

    NASA Astrophysics Data System (ADS)

    Wang, Linghua; Kodeck, Valérie; Van Vlierberghe, Sandra; Ren, Jun; Teng, Jie; Han, Xiuyou; Jian, Xigao; Baets, Roel; Morthier, Geert; Zhao, Mingshan

    2011-12-01

    Planar integrated optical biosensors are becoming more and more important as they facilitate label-free and real time monitoring biosensing with high sensitivity. In this paper, the systematic research on one kind of optical biosensor, based on a resonant principle in a polymer ring resonator, will be presented. Reduced footprint and high sensitivity are advantages of this kind of biosensor. Rather than expensive CMOS fabrication, the device with high performance is fabricated through a simple UV based soft imprint technique utilizing self-developed low loss polymer material. The measurement results for the bulk sensing of a NaCl solution and the surface sensing of a minimal amount of avidin molecules in a buffered solution will be presented.

  1. High-sensitivity ESCA instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davies, R.D.; Herglotz, H.K.; Lee, J.D.

    1973-01-01

    A new electron spectroscopy for chemical analysis (ESCA) instrument has been developed to provide high sensitivity and efficient operation for laboratory analysis of composition and chemical bonding in very thin surface layers of solid samples. High sensitivity is achieved by means of the high-intensity, efficient x-ray source described by Davies and Herglotz at the 1968 Denver X-Ray Conference, in combination with the new electron energy analyzer described by Lee at the 1972 Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy. A sample chamber designed to provide for rapid introduction and replacement of samples has adequate facilities for various sample treatmentsmore » and conditiouing followed immediately by ESCA analysis of the sample. Examples of application are presented, demonstrating the sensitivity and resolution achievable with this instrument. Its usefulness in trace surface analysis is shown and some chemical shifts'' measured by the instrument are compared with those obtained by x-ray spectroscopy. (auth)« less

  2. Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation Using Superconducting Tunnel Junctions with Integrated Radio Frequency Single-Electron Transistors

    NASA Technical Reports Server (NTRS)

    Stevenson, T. R.; Hsieh, W.-T.; Li, M. J.; Prober, D. E.; Rhee, K. W.; Schoelkopf, R. J.; Stahle, C. M.; Teufel, J.; Wollack, E. J.

    2004-01-01

    For high resolution imaging and spectroscopy in the FIR and submillimeter, space observatories will demand sensitive, fast, compact, low-power detector arrays with 104 pixels and sensitivity less than 10(exp -20) W/Hz(sup 0.5). Antenna-coupled superconducting tunnel junctions with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique. The device consists of an antenna to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure current through junctions contacting the absorber. We describe optimization of device parameters, and results on fabrication techniques for producing devices with high yield for detector arrays. We also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

  3. Miniature Cavity-Enhanced Diamond Magnetometer

    NASA Astrophysics Data System (ADS)

    Chatzidrosos, Georgios; Wickenbrock, Arne; Bougas, Lykourgos; Leefer, Nathan; Wu, Teng; Jensen, Kasper; Dumeige, Yannick; Budker, Dmitry

    2017-10-01

    We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042-nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT /√{Hz } , a projected photon shot-noise-limited sensitivity of 22 pT /√{Hz } , and an estimated quantum projection-noise-limited sensitivity of 0.43 pT /√{Hz } with the sensing volume of ˜390 μ m ×4500 μ m2 . The presented miniaturized device is the basis for an endoscopic magnetic-field sensor for biomedical applications.

  4. Sensitive Multi-Species Emissions Monitoring: Infrared Laser-Based Detection of Trace-Level Contaminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steill, Jeffrey D.; Huang, Haifeng; Hoops, Alexandra A.

    This report summarizes our development of spectroscopic chemical analysis techniques and spectral modeling for trace-gas measurements of highly-regulated low-concentration species present in flue gas emissions from utility coal boilers such as HCl under conditions of high humidity. Detailed spectral modeling of the spectroscopy of HCl and other important combustion and atmospheric species such as H 2 O, CO 2 , N 2 O, NO 2 , SO 2 , and CH 4 demonstrates that IR-laser spectroscopy is a sensitive multi-component analysis strategy. Experimental measurements from techniques based on IR laser spectroscopy are presented that demonstrate sub-ppm sensitivity levels to thesemore » species. Photoacoustic infrared spectroscopy is used to detect and quantify HCl at ppm levels with extremely high signal-to-noise even under conditions of high relative humidity. Additionally, cavity ring-down IR spectroscopy is used to achieve an extremely high sensitivity to combustion trace gases in this spectral region; ppm level CH 4 is one demonstrated example. The importance of spectral resolution in the sensitivity of a trace-gas measurement is examined by spectral modeling in the mid- and near-IR, and efforts to improve measurement resolution through novel instrument development are described. While previous project reports focused on benefits and complexities of the dual-etalon cavity ring-down infrared spectrometer, here details on steps taken to implement this unique and potentially revolutionary instrument are described. This report also illustrates and critiques the general strategy of IR- laser photodetection of trace gases leading to the conclusion that mid-IR laser spectroscopy techniques provide a promising basis for further instrument development and implementation that will enable cost-effective sensitive detection of multiple key contaminant species simultaneously.« less

  5. Normal range of serum highly-sensitive troponin-T in patients with chronic kidney disease stage 3-5.

    PubMed

    Chotivanawan, Thunnop; Krittayaphong, Rungroj

    2012-02-01

    Serum troponin-T concentrations are commonly increased in chronic kidney disease (CKD) without acute coronary syndrome. Highly-sensitive troponin-T the new tool that helpful for diagnosis of acute coronary syndrome, provides few data about normal value in patients with chronic kidney disease. The authors studied 89 patients with CKD stage 3-5: 40 had CKD stage 3, 26 had CKD stage 4 and 23 had CKD stage 5. Serum samples were collected for the analysis of highly-sensitive troponin-T levels. The values of highly-sensitive troponin-T of the total group and each CKD stage were presented. The level of highly-sensitive troponin-T in patients with CKD stage 3-5 was 0.044 +/- 0.076 ng/ml. For CKD stages 3, 4 and 5 levels were 0.015 +/- 0.016, 0.043 +/- 0.056, 0.098 +/- 0.121 ng/ml, respectively. 95th percentile of the total group was 0.139 ng/ml. 95th percentile for stage 3, 4 and 5 were 0.052, 0.136, 0.297 ng/ml, respectively. 95th percentile for highly-sensitive troponin-T of patients with CKD stage 3-5 was 0.139 ng/ml. This number may be considered as the cut-off value for diagnosis of acute myocardial infarction.

  6. Nanocrystalline SiC film thermistors for cryogenic applications

    NASA Astrophysics Data System (ADS)

    Mitin, V. F.; Kholevchuk, V. V.; Semenov, A. V.; Kozlovskii, A. A.; Boltovets, N. S.; Krivutsa, V. A.; Slepova, A. S.; Novitskii, S. V.

    2018-02-01

    We developed a heat-sensitive material based on nanocrystalline SiC films obtained by direct deposition of carbon and silicon ions onto sapphire substrates. These SiC films can be used for resistance thermometers operating in the 2 K-300 K temperature range. Having high heat sensitivity, they are relatively low sensitive to the magnetic field. The designs of the sensors are presented together with a discussion of their thermometric characteristics and sensitivity to magnetic fields.

  7. Novel experimental design for high pressure-high temperature electrical resistance measurements in a "Paris-Edinburgh" large volume press.

    PubMed

    Matityahu, Shlomi; Emuna, Moran; Yahel, Eyal; Makov, Guy; Greenberg, Yaron

    2015-04-01

    We present a novel experimental design for high sensitivity measurements of the electrical resistance of samples at high pressures (0-6 GPa) and high temperatures (300-1000 K) in a "Paris-Edinburgh" type large volume press. Uniquely, the electrical measurements are carried out directly on a small sample, thus greatly increasing the sensitivity of the measurement. The sensitivity to even minor changes in electrical resistance can be used to clearly identify phase transitions in material samples. Electrical resistance measurements are relatively simple and rapid to execute and the efficacy of the present experimental design is demonstrated by measuring the electrical resistance of Pb, Sn, and Bi across a wide domain of temperature-pressure phase space and employing it to identify the loci of phase transitions. Based on these results, the phase diagrams of these elements are reconstructed to high accuracy and found to be in excellent agreement with previous studies. In particular, by mapping the locations of several well-studied reference points in the phase diagram of Sn and Bi, it is demonstrated that a standard calibration exists for the temperature and pressure, thus eliminating the need for direct or indirect temperature and pressure measurements. The present technique will allow simple and accurate mapping of phase diagrams under extreme conditions and may be of particular importance in advancing studies of liquid state anomalies.

  8. Novel EUV photoresist for sub-7nm node (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Furukawa, Tsuyoshi; Naruoka, Takehiko; Nakagawa, Hisashi; Miyata, Hiromu; Shiratani, Motohiro; Hori, Masafumi; Dei, Satoshi; Ayothi, Ramakrishnan; Hishiro, Yoshi; Nagai, Tomoki

    2017-04-01

    Extreme ultraviolet (EUV) lithography has been recognized as a promising candidate for the manufacturing of semiconductor devices as LS and CH pattern for 7nm node and beyond. EUV lithography is ready for high volume manufacturing stage. For the high volume manufacturing of semiconductor devices, significant improvement of sensitivity and line edge roughness (LWR) and Local CD Uniformity (LCDU) is required for EUV resist. It is well-known that the key challenge for EUV resist is the simultaneous requirement of ultrahigh resolution (R), low line edge roughness (L) and high sensitivity (S). Especially high sensitivity and good roughness is important for EUV lithography high volume manufacturing. We are trying to improve sensitivity and LWR/LCDU from many directions. From material side, we found that both sensitivity and LWR/LCDU are simultaneously improved by controlling acid diffusion length and efficiency of acid generation using novel resin and PAG. And optimizing EUV integration is one of the good solution to improve sensitivity and LWR/LCDU. We are challenging to develop new multi-layer materials to improve sensitivity and LWR/LCDU. Our new multi-layer materials are designed for best performance in EUV lithography system. From process side, we found that sensitivity was substantially improved maintaining LWR applying novel type of chemical amplified resist (CAR) and process. EUV lithography evaluation results obtained for new CAR EUV interference lithography. And also metal containing resist is one possibility to break through sensitivity and LWR trade off. In this paper, we will report the recent progress of sensitivity and LWR/LCDU improvement of JSR novel EUV resist and process.

  9. Highly sensitive biochemical sensor utilizing Bragg grating in submicron Si/SiO2 waveguides

    NASA Astrophysics Data System (ADS)

    Tripathi, Saurabh Mani; Kumar, Arun; Meunier, Jean-Pierre; Marin, Emmanuel

    2009-05-01

    We present a novel highly sensitive biochemical sensor based on a Bragg grating written in the cladding region of a submicron planar Si/SiO2 waveguide. Owing to the high refractive index contrast at the Si/SiO2 boundary the TM modal power is relatively high in low refractive index sensing region, leading to higher sensitivity in this configuration [1]. Waveguide parameters have been optimized to obtain maximum modal power in the sensing region (PSe) and an optimum core width corresponding to maximum sensitivity is found to exist while operating in TM mode configuration, as has been shown in Fig. 1. It has been found that operating in TM mode configuration at optimum core width the structure exhibits extremely high sensitivity, ~ 5×10-6 RIU - 1.35×10-6 RIU for the ambient refractive indices between 1.33 - 1.63. Such high sensitivities are typically attainable for Surface Plasmon Polariton (SPP) based biosensors and is much higher than any non SPP based sensors. Being free from any metallic layer or bulky prism the structure is easy to realize. Owing to its simple structure and small dimensions the proposed sensor can be integrated with planar lightwave circuits and could be used in handy lab-on-a-chip devices. The device may find application in highly sensitive biological/chemical sensing areas in civil and defense sectors where analyzing the samples at the point of need is required rather than sending it to some centralized laboratory.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogura, Toshihiko, E-mail: t-ogura@aist.go.jp

    Highlights: • We developed a high-sensitive frequency transmission electric-field (FTE) system. • The output signal was highly enhanced by applying voltage to a metal layer on SiN. • The spatial resolution of new FTE method is 41 nm. • New FTE system enables observation of the intact bacteria and virus in water. - Abstract: The high-resolution structural analysis of biological specimens by scanning electron microscopy (SEM) presents several advantages. Until now, wet bacterial specimens have been examined using atmospheric sample holders. However, images of unstained specimens in water using these holders exhibit very poor contrast and heavy radiation damage. Recently,more » we developed the frequency transmission electric-field (FTE) method, which facilitates the SEM observation of biological specimens in water without radiation damage. However, the signal detection system presents low sensitivity. Therefore, a high EB current is required to generate clear images, and thus reducing spatial resolution and inducing thermal damage to the samples. Here a high-sensitivity detection system is developed for the FTE method, which enhances the output signal amplitude by hundredfold. The detection signal was highly enhanced when voltage was applied to the metal layer on silicon nitride thin film. This enhancement reduced the EB current and improved the spatial resolution as well as the signal-to-noise ratio. The spatial resolution of a high-sensitive FTE system is 41 nm, which is considerably higher than previous FTE system. New FTE system can easily be utilised to examine various unstained biological specimens in water, such as living bacteria and viruses.« less

  11. New silver-halide-sensitized gelatin material: the influence of bleaches on holograms

    NASA Astrophysics Data System (ADS)

    Zhang, Weiping; Pang, Lin; Guo, Lurong

    1996-12-01

    A new high-resolution-silver-halide (HRSH-II) material was produced, which has proper initial hardness for fabricating silver halide sensitized gelatin (SHSG) holograms. That would avoid high noise by seeking the gelatin in hot water. With different alkali halide component in B solution and its concentration (the ratio B/A), experiments were presented about bleaching effect with R-10 on processing for SHSG derived from this new material. High diffraction efficiency, as high as 81%, was achieved. Some of the observations are discussed.

  12. Broadband External-Cavity Diode Laser

    NASA Technical Reports Server (NTRS)

    Pilgrim, Jeffrey S.

    2005-01-01

    A broadband external-cavity diode laser (ECDL) has been invented for use in spectroscopic surveys preparatory to optical detection of gases. Heretofore, commercially available ECDLs have been designed, in conjunction with sophisticated tuning assemblies, for narrow- band (and, typically, single-frequency) operation, as needed for high sensitivity and high spectral resolution in some gas-detection applications. However, for preparatory spectroscopic surveys, high sensitivity and narrow-band operation are not needed; in such cases, the present broadband ECDL offers a simpler, less-expensive, more-compact alternative to a commercial narrowband ECDL.

  13. High-affinity K+ uptake in pepper plants.

    PubMed

    Martínez-Cordero, M Angeles; Martínez, Vicente; Rubio, Francisco

    2005-06-01

    High-affinity K+ uptake is an essential process for plant nutrition under K+-limiting conditions. The results presented here demonstrate that pepper (Capsicum annuum) plants grown in the absence of NH4+ and starved of K+ show an NH4+-sensitive high-affinity K+ uptake that allows plant roots to deplete external K+ to values below 1 microM. When plants are grown in the presence of NH4+, high-affinity K+ uptake is not inhibited by NH4+. Although NH4+-grown plants deplete external K+ below 1 microM in the absence of NH4+, when 1 mM NH4+ is present they do not deplete external K+ below 10 microM. A K+ transporter of the HAK family, CaHAK1, is very likely mediating the NH4+-sensitive component of the high-affinity K+ uptake in pepper roots. CaHAK1 is strongly induced in the roots that show the NH4+-sensitive high-affinity K+ uptake and its induction is reduced in K+-starved plants grown in the presence of NH4+. The NH4+-insensitive K+ uptake may be mediated by an AKT1-like K+ channel.

  14. Fear improves mental rotation of low-spatial-frequency visual representation.

    PubMed

    Borst, Grégoire

    2013-10-01

    Previous studies have demonstrated that the brief presentation of a fearful face improves not only low-level visual processing such as contrast and orientation sensitivity but also improves visuospatial processing. In the present study, we investigated whether fear improves mental rotation efficiency (i.e., the mental rotation rate) because of the effect of fear on the sensitivity of magnocellular neurons. We asked 2 groups of participants to perform a mental rotation task with either low-pass or high-pass filtered 3-dimensional objects. Following the presentation of a fearful face, participants mentally rotated objects faster compared with when a neutral face was presented but only for low-pass filtered objects. The results suggest that fear improves mental rotation efficiency by increasing sensitivity to motion-related visual information within the magnocellular pathway.

  15. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, T.; Jensen, R.; Christensen, M. K.

    2012-07-15

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/{Delta}m > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detectionmore » by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH{sub 3}.« less

  16. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

    NASA Astrophysics Data System (ADS)

    Andersen, T.; Jensen, R.; Christensen, M. K.; Pedersen, T.; Hansen, O.; Chorkendorff, I.

    2012-07-01

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/Δm > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH3.

  17. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors.

    PubMed

    Andersen, T; Jensen, R; Christensen, M K; Pedersen, T; Hansen, O; Chorkendorff, I

    2012-07-01

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/Δm > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH(3).

  18. Optical fiber strain sensor for application in intelligent intruder detection systems

    NASA Astrophysics Data System (ADS)

    Stańczyk, Tomasz; Tenderenda, Tadeusz; Szostkiewicz, Lukasz; Bienkowska, Beata; Kunicki, Daniel; Murawski, Michal; Mergo, Pawel; Nasilowski, Tomasz

    2017-10-01

    Nowadays technology allows to create highly effective Intruder Detection Systems (IDS), that are able to detect the presence of an intruder within a defined area. In such systems the best performance can be achieved by combining different detection techniques in one system. One group of devices that can be applied in an IDS, are devices based on Fiber Optic Sensors (FOS). The FOS benefits from numerous advantages of optical fibers like: small size, light weight or high sensitivity. In this work we present a novel Microstructured Optical Fiber (MOF) characterized by increased strain sensitivity dedicated to distributed acoustic sensing for intelligent intruder detection systems. By designing the MOF with large air holes in close proximity to a fiber core, we increased the effective refractive index sensitivity to longitudinal strain. The presented fiber can be easily integrated in a floor system in order to detect any movement in the investigated area. We believe that sensors, based on the presented MOF, due to its numerous advantages, can find application in intelligent IDS.

  19. Nanozyme-based bio-barcode assay for high sensitive and logic-controlled specific detection of multiple DNAs.

    PubMed

    Lin, Xiaodong; Liu, Yaqing; Tao, Zhanhui; Gao, Jinting; Deng, Jiankang; Yin, Jinjin; Wang, Shuo

    2017-08-15

    Since HCV and HIV share a common transmission path, high sensitive detection of HIV and HCV gene is of significant importance to improve diagnosis accuracy and cure rate at early stage for HIV virus-infected patients. In our investigation, a novel nanozyme-based bio-barcode fluorescence amplified assay is successfully developed for simultaneous detection of HIV and HCV DNAs with excellent sensitivity in an enzyme-free and label-free condition. Here, bimetallic nanoparticles, PtAu NPs , present outstanding peroxidase-like activity and act as barcode to catalyze oxidation of nonfluorescent substrate of amplex red (AR) into fluorescent resorufin generating stable and sensitive "Turn On" fluorescent output signal, which is for the first time to be integrated with bio-barcode strategy for fluorescence detection DNA. Furthermore, the provided strategy presents excellent specificity and can distinguish single-base mismatched mutant from target DNA. What interesting is that cascaded INHIBIT-OR logic gate is integrated with biosensors for the first time to distinguish individual target DNA from each other under logic function control, which presents great application in development of rapid and intelligent detection. Copyright © 2017. Published by Elsevier B.V.

  20. Novel Designs for Application Specific MEMS Pressure Sensors

    PubMed Central

    Fragiacomo, Giulio; Reck, Kasper; Lorenzen, Lasse; Thomsen, Erik V.

    2010-01-01

    In the framework of developing innovative microfabricated pressure sensors, we present here three designs based on different readout principles, each one tailored for a specific application. A touch mode capacitive pressure sensor with high sensitivity (14 pF/bar), low temperature dependence and high capacitive output signal (more than 100 pF) is depicted. An optical pressure sensor intrinsically immune to electromagnetic interference, with large pressure range (0–350 bar) and a sensitivity of 1 pm/bar is presented. Finally, a resonating wireless pressure sensor power source free with a sensitivity of 650 KHz/mmHg is described. These sensors will be related with their applications in harsh environment, distributed systems and medical environment, respectively. For many aspects, commercially available sensors, which in vast majority are piezoresistive, are not suited for the applications proposed. PMID:22163425

  1. Polystyrene Oxygen Optodes Doped with Ir(III) and Pd(II) meso-Tetrakis(pentafluorophenyl)porphyrin Using an LED-Based High-Sensitivity Phosphorimeter.

    PubMed

    Filho, Alexandre F De Moraes; Gewehr, Pedro M; Maia, Joaquim M; Jakubiak, Douglas R

    2018-06-15

    This paper presents a gaseous oxygen detection system based on time-resolved phosphorimetry (time-domain), which is used to investigate O2 optical transducers. The primary sensing elements were formed by incorporating iridium(III) and palladium(II) meso -tetrakis(pentafluorophenyl)porphyrin complexes (IrTFPP-CO-Cl and PdTFPP) in polystyrene (PS) solid matrices. Probe excitation was obtained using a violet light-emitting diode (LED) (low power), and the resulting phosphorescence was detected by a high-sensitivity compact photomultiplier tube. The detection system performance and the preparation of the transducers are presented along with their optical properties, phosphorescence lifetimes, calibration curves and photostability. The developed lifetime measuring system showed a good signal-to-noise ratio, and reliable results were obtained from the optodes, even when exposed to moderate levels of O2. The new IrTFPP-CO-Cl membranes exhibited room temperature phosphorescence and moderate sensitivity: <τ0>/<τ21%> ratio of ≈6. A typically high degree of dynamic phosphorescence quenching was observed for the traditional indicator PdTFPP: <τ0>/<τ21%> ratio of ≈36. Pulsed-source time-resolved phosphorimetry combined with a high-sensitivity photodetector can offer potential advantages such as: (i) major dynamic range, (ii) extended temporal resolution (Δτ/Δ[O2]) and (iii) high operational stability. IrTFPP-CO-Cl immobilized in polystyrene is a promising alternative for O2 detection, offering adequate photostability and potentially mid-range sensitivity over Pt(II) and Pd(II) metalloporphyrins.

  2. Rapid Rule-Out of Acute Myocardial Injury Using a Single High-Sensitivity Cardiac Troponin I Measurement.

    PubMed

    Sandoval, Yader; Smith, Stephen W; Shah, Anoop S V; Anand, Atul; Chapman, Andrew R; Love, Sara A; Schulz, Karen; Cao, Jing; Mills, Nicholas L; Apple, Fred S

    2017-01-01

    Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration

  3. External validation of heart-type fatty acid binding protein, high-sensitivity cardiac troponin, and electrocardiography as rule-out for acute myocardial infarction.

    PubMed

    Van Hise, Christopher B; Greenslade, Jaimi H; Parsonage, William; Than, Martin; Young, Joanna; Cullen, Louise

    2018-02-01

    To externally validate a clinical decision rule incorporating heart fatty acid binding protein (h-FABP), high-sensitivity troponin (hs-cTn) and electrocardiogram (ECG) for the detection of acute myocardial infarction (AMI) on presentation to the Emergency Department. We also investigated whether this clinical decision rule improved identification of AMI over algorithms incorporating hs-cTn and ECG only. This study included data from 789 patients from the Brisbane ADAPT cohort and 441 patients from the Christchurch TIMI RCT cohort. The primary outcome was index AMI. Sensitivity, specificity, positive predictive value and negative predictive value were used to assess the diagnostic accuracy of the algorithms. 1230 patients were recruited, including 112 (9.1%) with AMI. The algorithm including h-FABP and hs-cTnT had 100% sensitivity and 32.4% specificity. The algorithm utilising h-FABP and hs-cTnI had similar sensitivity (99.1%) and higher specificity (43.4%). The hs-cTnI and hs-cTnT algorithms without h-FABP both had a sensitivity of 98.2%; a result that was not significantly different from either algorithm incorporating h-FABP. Specificity was higher for the hs-cTnI algorithm (68.1%) compared to the hs-cTnT algorithm (33.0%). The specificity of the algorithm incorporating hs-cTnI alone was also significantly higher than both of the algorithms incorporating h-FABP (p<0.01). For patients presenting to the Emergency Department with chest pain, an algorithm incorporating h-FABP, hs-cTn and ECG has high accuracy and can rule out up to 40% of patients. An algorithm incorporating only hs-cTn and ECG has similar sensitivity and may rule out a higher proportion of patients. Each of the algorithms can be used to safely identify patients as low risk for AMI on presentation to the Emergency Department. Copyright © 2017 The Canadian Society of Clinical Chemists. All rights reserved.

  4. Sensitivity and specificity of radiographic methods for predicting insertion torque of dental implants.

    PubMed

    Cortes, Arthur Rodriguez Gonzalez; Eimar, Hazem; Barbosa, Jorge de Sá; Costa, Claudio; Arita, Emiko Saito; Tamimi, Faleh

    2015-05-01

    Subjective radiographic classifications of alveolar bone have been proposed and correlated with implant insertion torque (IT). The present diagnostic study aims to identify quantitative bone features influencing IT and to use these findings to develop an objective radiographic classification for predicting IT. Demographics, panoramic radiographs (taken at the beginning of dental treatment), and cone-beam computed tomographic scans (taken for implant surgical planning) of 25 patients receiving 31 implants were analyzed. Bone samples retrieved from implant sites were assessed with dual x-ray absorptiometry, microcomputed tomography, and histology. Odds ratio, sensitivity, and specificity of all variables to predict high peak IT were assessed. A ridge cortical thickness >0.75 mm and a normal appearance of the inferior mandibular cortex were the most sensitive variables for predicting high peak IT (87.5% and 75%, respectively). A classification based on the combination of both variables presented high sensitivity (90.9%) and specificity (100%) for predicting IT. Within the limitations of this study, the results suggest that it is possible to predict IT accurately based on radiographic findings of the patient. This could be useful in the treatment plan of immediate loading cases.

  5. Design of nanostructured-based glucose biosensors

    NASA Astrophysics Data System (ADS)

    Komirisetty, Archana; Williams, Frances; Pradhan, Aswini; Konda, Rajini B.; Dondapati, Hareesh; Samantaray, Diptirani

    2012-04-01

    This paper presents the design of glucose sensors that will be integrated with advanced nano-materials, bio-coatings and electronics to create novel devices that are highly sensitive, inexpensive, accurate, and reliable. In the work presented, a glucose biosensor and its fabrication process flow have been designed. The device is based on electrochemical sensing using a working electrode with bio-functionalized zinc oxide (ZnO) nano-rods. Among all metal oxide nanostructures, ZnO nano-materials play a significant role as a sensing element in biosensors due to their properties such as high isoelectric point (IEP), fast electron transfer, non-toxicity, biocompatibility, and chemical stability which are very crucial parameters to achieve high sensitivity. Amperometric enzyme electrodes based on glucose oxidase (GOx) are used due to their stability and high selectivity to glucose. The device also consists of silicon dioxide and titanium layers as well as platinum working and counter electrodes and a silver/silver chloride reference electrode. Currently, the biosensors are being fabricated using the process flow developed. Once completed, the sensors will be bio-functionalized and tested to characterize their performance, including their sensitivity and stability.

  6. Inhomogeneous Forcing and Transient Climate Sensitivity

    NASA Technical Reports Server (NTRS)

    Shindell, Drew T.

    2014-01-01

    Understanding climate sensitivity is critical to projecting climate change in response to a given forcing scenario. Recent analyses have suggested that transient climate sensitivity is at the low end of the present model range taking into account the reduced warming rates during the past 10-15 years during which forcing has increased markedly. In contrast, comparisons of modelled feedback processes with observations indicate that the most realistic models have higher sensitivities. Here I analyse results from recent climate modelling intercomparison projects to demonstrate that transient climate sensitivity to historical aerosols and ozone is substantially greater than the transient climate sensitivity to CO2. This enhanced sensitivity is primarily caused by more of the forcing being located at Northern Hemisphere middle to high latitudes where it triggers more rapid land responses and stronger feedbacks. I find that accounting for this enhancement largely reconciles the two sets of results, and I conclude that the lowest end of the range of transient climate response to CO2 in present models and assessments (less than 1.3 C) is very unlikely.

  7. The Design and Optimization of a Highly Sensitive and Overload-Resistant Piezoresistive Pressure Sensor

    PubMed Central

    Meng, Xiawei; Zhao, Yulong

    2016-01-01

    A piezoresistive pressure sensor with a beam-membrane-dual-island structure is developed for micro-pressure monitoring in the field of aviation, which requires great sensitivity and overload resistance capacity. The design, fabrication, and test of the sensor are presented in this paper. By analyzing the stress distribution of sensitive elements using the finite element method, a novel structure incorporating sensitive beams with a traditional bossed diaphragm is built up. The proposed structure proved to be advantageous in terms of high sensitivity and high overload resistance compared with the conventional bossed diaphragm and flat diaphragm structures. Curve fittings of surface stress and deflection based on ANSYS simulation results are performed to establish the sensor equations. Fabricated on an n-type single crystal silicon wafer, the sensor chips are wire-bonded to a printed circuit board (PCB) and packaged for experiments. The static and dynamic characteristics are tested and discussed. Experimental results show that the sensor has a sensitivity as high as 17.339 μV/V/Pa in the range of 500 Pa at room temperature, and a high overload resistance of 200 times overpressure. Due to the excellent performance, the sensor can be applied in measuring micro-pressure lower than 500 Pa. PMID:27005627

  8. Temperature sensitive surfaces and methods of making same

    DOEpatents

    Liang, Liang [Richland, WA; Rieke, Peter C [Pasco, WA; Alford, Kentin L [Pasco, WA

    2002-09-10

    Poly-n-isopropylacrylamide surface coatings demonstrate the useful property of being able to switch charateristics depending upon temperature. More specifically, these coatings switch from being hydrophilic at low temperature to hydrophobic at high temperature. Research has been conducted for many years to better characterize and control the properties of temperature sensitive coatings. The present invention provides novel temperature sensitive coatings on articles and novel methods of making temperature sensitive coatings that are disposed on the surfaces of various articles. These novel coatings contain the reaction products of n-isopropylacrylamide and are characterized by their properties such as advancing contact angles. Numerous other characteristics such as coating thickness, surface roughness, and hydrophilic-to-hydrophobic transition temperatures are also described. The present invention includes articles having temperature-sensitve coatings with improved properties as well as improved methods for forming temperature sensitive coatings.

  9. Automatic high-sensitivity control of suspended pollutants in drinking and natural water

    NASA Astrophysics Data System (ADS)

    Akopov, Edmund I.; Karabegov, M.; Ovanesyan, A.

    1993-11-01

    This article presents a description of the new instrumental method and device for automatic measurement of water turbidity (WT) by means of photoelectron flow ultramicroscope (PFU). The method presents the WT determination by measuring the number concentration (number of particles suspended in 1 cm3 of water under study) using the PFU and demonstrates much higher sensitivity and accuracy in comparison with the usual methods--turbidimetry and nephelometry.

  10. Strain Sensors with Adjustable Sensitivity by Tailoring the Microstructure of Graphene Aerogel/PDMS Nanocomposites.

    PubMed

    Wu, Shuying; Ladani, Raj B; Zhang, Jin; Ghorbani, Kamran; Zhang, Xuehua; Mouritz, Adrian P; Kinloch, Anthony J; Wang, Chun H

    2016-09-21

    Strain sensors with high elastic limit and high sensitivity are required to meet the rising demand for wearable electronics. Here, we present the fabrication of highly sensitive strain sensors based on nanocomposites consisting of graphene aerogel (GA) and polydimethylsiloxane (PDMS), with the primary focus being to tune the sensitivity of the sensors by tailoring the cellular microstructure through controlling the manufacturing processes. The resultant nanocomposite sensors exhibit a high sensitivity with a gauge factor of up to approximately 61.3. Of significant importance is that the sensitivity of the strain sensors can be readily altered by changing the concentration of the precursor (i.e., an aqueous dispersion of graphene oxide) and the freezing temperature used to process the GA. The results reveal that these two parameters control the cell size and cell-wall thickness of the resultant GA, which may be correlated to the observed variations in the sensitivities of the strain sensors. The higher is the concentration of graphene oxide, then the lower is the sensitivity of the resultant nanocomposite strain sensor. Upon increasing the freezing temperature from -196 to -20 °C, the sensitivity increases and reaches a maximum value of 61.3 at -50 °C and then decreases with a further increase in freezing temperature to -20 °C. Furthermore, the strain sensors offer excellent durability and stability, with their piezoresistivities remaining virtually unchanged even after 10 000 cycles of high-strain loading-unloading. These novel findings pave the way to custom design strain sensors with a desirable piezoresistive behavior.

  11. The Efficacy of Vigorous-Intensity Exercise as an Aid to Smoking Cessation in Adults With High Anxiety Sensitivity: A Randomized Controlled Trial.

    PubMed

    Smits, Jasper A J; Zvolensky, Michael J; Davis, Michelle L; Rosenfield, David; Marcus, Bess H; Church, Timothy S; Powers, Mark B; Frierson, Georita M; Otto, Michael W; Hopkins, Lindsey B; Brown, Richard A; Baird, Scarlett O

    2016-04-01

    High anxiety sensitivity predicts poor smoking cessation outcomes. Aerobic exercise reduces anxiety sensitivity and aspects of the risk conferred by anxiety sensitivity. In the current study, we examined whether exercise can aid smoking cessation in adults with high anxiety sensitivity. Participants were sedentary and low-activity adult daily smokers (n = 136) with elevated prescreen anxiety sensitivity. Participants received 15 weeks of standard smoking cessation treatment (ST; cognitive behavioral therapy plus nicotine replacement therapy). In addition, participants were simultaneously randomized to 15 weeks of either an exercise intervention (ST + EX; n = 72) or a wellness education control condition (ST + CTRL; n = 64). Self-reported smoking abstinence was assessed weekly during the intervention, at the end of treatment (10 weeks after the target quit date), and at 4 and 6 months after the target quit date. Abstinence was verified by expired carbon monoxide readings and saliva cotinine. Results indicated that point prevalence abstinence (PPA) and prolonged abstinence (PA) rates were significantly higher for ST + EX than for ST + CTRL at each of the major end points among persons with high anxiety sensitivity (PPA: b = -0.91, standard error [SE] = 0.393, t(1171) = -2.33, p = .020; PA: b = -0.98, SE = 0.346, t(132) = -2.84, p = .005), but not among those with low anxiety sensitivity (PPA: b = -0.23, SE = 0.218, t(1171) = -1.06, p = .29; PA: b = -0.31, SE = 0.306, t(132) = -1.01, p = .32). The present results suggest that exercise facilitates the odds of quit success for smokers with high levels of anxiety sensitivity and therefore may be a useful therapeutic tactic for this high-risk segment of the smoking population. ClinicalTrials.gov, NCT01065506.

  12. The Efficacy of Vigorous-Intensity Exercise as an Aid to Smoking Cessation in Adults with High Anxiety Sensitivity: A Randomized Controlled Trial

    PubMed Central

    Smits, Jasper A. J.; Zvolensky, Michael J.; Davis, Michelle L.; Rosenfield, David; Marcus, Bess H.; Church, Timothy S.; Powers, Mark B.; Frierson, Georita M.; Otto, Michael W.; Hopkins, Lindsey B.; Brown, Richard A.; Baird, Scarlett O.

    2015-01-01

    Objective High anxiety sensitivity predicts poor smoking cessation outcomes. Aerobic exercise reduces anxiety sensitivity and aspects of the risk conferred by anxiety sensitivity. In the current study, we examined whether exercise can aid smoking cessation in adults with high anxiety sensitivity. Method Participants were sedentary and low activity adult daily smokers (N = 136) with elevated prescreen anxiety sensitivity. Participants received 15 weeks of standard smoking cessation treatment (ST: cognitive behavioral therapy plus nicotine replacement therapy). Additionally, participants were simultaneously randomized to 15 weeks of either an exercise intervention (ST+EX; n = 72) or a wellness education control condition (ST+CTRL; n = 64). Self-reported smoking abstinence was assessed weekly during the intervention, at the end of treatment (10 weeks following the target quit date), and at 4 and 6 months following the target quit date. Abstinence was verified by expired carbon monoxide readings and saliva cotinine. Results Results indicated that point prevalence abstinence (PPA) and prolonged abstinence (PA) rates were significantly higher for ST+EX than for ST+CTRL at each of the major end points among persons with high anxiety sensitivity (PPA: b=−.91, SE=.393, t(1171)=−2.33, p=.020; PA: b=−.98, SE=.346, t(132)=−2.84, p=.005), but not among those with low anxiety sensitivity (PPA: b=−.23, SE=.218, t(1171)=−1.06, p=..29; PA: b=−.31, SE=.306, t(132)=−1.01, p=.32) Conclusions The present results suggest that exercise faciliates the odds of quit success for smokers with high levels of anxiety sensitivity, and therefore, may be a useful therapeutic tactic for this high-risk segment of the smoking population. PMID:26513517

  13. Chromatic spatial contrast sensitivity estimated by visual evoked cortical potential and psychophysics

    PubMed Central

    Barboni, M.T.S.; Gomes, B.D.; Souza, G.S.; Rodrigues, A.R.; Ventura, D.F.; Silveira, L.C.L.

    2013-01-01

    The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus. PMID:23369980

  14. Highly sensitive protein detection using a plasmonic field effect transistor (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Shokri-Kojori, Hossein; Ji, Yiwen; Han, Xu; Paik, Younghun; Braunschweig, Adam; Kim, Sung Jin

    2016-03-01

    Localized surface Plasmon Resonance (LSPR) is a nanoscale phenomenon which presents strong resonance associated with noble metal nanostructures. This plasmon resonance based technology enables highly sensitive detection for chemical and biological applications. Recently, we have developed a plasmon field effect transistor (FET) that enables direct plasmonic-to-electric signal conversion with signal amplification. The plasmon FET consists of back-gated field effect transistor incorporated with gold nanoparticles on top of the FET channel. The gold nanostructures are physically separated from transistor electrodes and can be functionalized for a specific biological application. In this presentation, we report a successful demonstration of a model system to detect Con A proteins using Carbohydrate linkers as a capture molecule. The plasmon FET detected a very low concentration of Con A (0.006 mg/L) while it offers a wide dynamic range of 0.006-50 mg/L. In this demonstration, we used two-color light sources instead of a bulky spectrometer to achieve high sensitivity and wide dynamic range. The details of two-color based differential measurement method will be discussed. This novel protein-based sensor has several advantages such as extremely small size for point-of-care system, multiplexing capability, no need of complex optical geometry.

  15. Least Squares Shadowing Sensitivity Analysis of Chaotic Flow Around a Two-Dimensional Airfoil

    NASA Technical Reports Server (NTRS)

    Blonigan, Patrick J.; Wang, Qiqi; Nielsen, Eric J.; Diskin, Boris

    2016-01-01

    Gradient-based sensitivity analysis has proven to be an enabling technology for many applications, including design of aerospace vehicles. However, conventional sensitivity analysis methods break down when applied to long-time averages of chaotic systems. This breakdown is a serious limitation because many aerospace applications involve physical phenomena that exhibit chaotic dynamics, most notably high-resolution large-eddy and direct numerical simulations of turbulent aerodynamic flows. A recently proposed methodology, Least Squares Shadowing (LSS), avoids this breakdown and advances the state of the art in sensitivity analysis for chaotic flows. The first application of LSS to a chaotic flow simulated with a large-scale computational fluid dynamics solver is presented. The LSS sensitivity computed for this chaotic flow is verified and shown to be accurate, but the computational cost of the current LSS implementation is high.

  16. Re-scan confocal microscopy: scanning twice for better resolution.

    PubMed

    De Luca, Giulia M R; Breedijk, Ronald M P; Brandt, Rick A J; Zeelenberg, Christiaan H C; de Jong, Babette E; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A; Stallinga, Sjoerd; Manders, Erik M M

    2013-01-01

    We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required.

  17. High Sensitivity Combined with Extended Structural Coverage of Labile Compounds via Nanoelectrospray Ionization at Subambient Pressures

    DOE PAGES

    Cox, Jonathan T.; Kronewitter, Scott R.; Shukla, Anil K.; ...

    2014-09-15

    Subambient pressure ionization with nanoelectrospray (SPIN) has proven to be effective in producing ions with high efficiency and transmitting them to low pressures for high sensitivity mass spectrometry (MS) analysis. Here we present evidence that not only does the SPIN source improve MS sensitivity but also allows for gentler ionization conditions. The gentleness of a conventional heated capillary electrospray ionization (ESI) source and the SPIN source was compared by the liquid chromatography mass spectrometry (LC-MS) analysis of colominic acid. Colominic acid is a mixture of sialic acid polymers of different lengths containing labile glycosidic linkages between monomer units necessitating amore » gentle ion source. By coupling the SPIN source with high resolution mass spectrometry and using advanced data processing tools, we demonstrate much extended coverage of sialic acid polymer chains as compared to using the conventional ESI source. Additionally we show that SPIN-LC-MS is effective in elucidating polymer features with high efficiency and high sensitivity previously unattainable by the conventional ESI-LC-MS methods.« less

  18. Enhanced sensitivity for optical loss measurement in planar thin-films (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Yuan, Hua-Kang

    2016-09-01

    An organic-inorganic hybrid material benefits from processing advantages of organics and high refractive indices of inorganics. We focus on a titanium oxide hydrate system combined with common bulk polymers. In particular, we target thin-film structures of a few microns in thickness. Traditional Beer-Lambert approaches for measuring optical losses can only provide an upper limit estimate. This sensitivity is highly limited when considering the low-losses required for mid-range optical applications, on the order of 0.1 cm-1. For intensity based measurements, improving the sensitivity requires an increase in the optical path length. Instead, a new sensitive technique suitable for simple planar thin films is required. A number of systems were modelled to measure optical losses in films of 1 micron thick. The presented techniques utilise evanescent waves and total internal reflection to increase optical path length through the material. It was found that a new way of using prism coupling provides the greatest improvement in sensitivity. In keeping the requirements on the material simple, this method for measuring loss is well suited to any future developments of new materials in thin-film structures.

  19. New sensitive high-performance liquid chromatography-tandem mass spectrometry method for the detection of horse and pork in halal beef.

    PubMed

    von Bargen, Christoph; Dojahn, Jörg; Waidelich, Dietmar; Humpf, Hans-Ulrich; Brockmeyer, Jens

    2013-12-11

    The accidental or fraudulent blending of meat from different species is a highly relevant aspect for food product quality control, especially for consumers with ethical concerns against species, such as horse or pork. In this study, we present a sensitive mass spectrometrical approach for the detection of trace contaminations of horse meat and pork and demonstrate the specificity of the identified biomarker peptides against chicken, lamb, and beef. Biomarker peptides were identified by a shotgun proteomic approach using tryptic digests of protein extracts and were verified by the analysis of 21 different meat samples from the 5 species included in this study. For the most sensitive peptides, a multiple reaction monitoring (MRM) method was developed that allows for the detection of 0.55% horse or pork in a beef matrix. To enhance sensitivity, we applied MRM(3) experiments and were able to detect down to 0.13% pork contamination in beef. To the best of our knowledge, we present here the first rapid and sensitive mass spectrometrical method for the detection of horse and pork by use of MRM and MRM(3).

  20. Real-Time and In-Flow Sensing Using a High Sensitivity Porous Silicon Microcavity-Based Sensor.

    PubMed

    Caroselli, Raffaele; Martín Sánchez, David; Ponce Alcántara, Salvador; Prats Quilez, Francisco; Torrijos Morán, Luis; García-Rupérez, Jaime

    2017-12-05

    Porous silicon seems to be an appropriate material platform for the development of high-sensitivity and low-cost optical sensors, as their porous nature increases the interaction with the target substances, and their fabrication process is very simple and inexpensive. In this paper, we present the experimental development of a porous silicon microcavity sensor and its use for real-time in-flow sensing application. A high-sensitivity configuration was designed and then fabricated, by electrochemically etching a silicon wafer. Refractive index sensing experiments were realized by flowing several dilutions with decreasing refractive indices, and measuring the spectral shift in real-time. The porous silicon microcavity sensor showed a very linear response over a wide refractive index range, with a sensitivity around 1000 nm/refractive index unit (RIU), which allowed us to directly detect refractive index variations in the 10 -7 RIU range.

  1. Analyses of a heterogeneous lattice hydrodynamic model with low and high-sensitivity vehicles

    NASA Astrophysics Data System (ADS)

    Kaur, Ramanpreet; Sharma, Sapna

    2018-06-01

    Basic lattice model is extended to study the heterogeneous traffic by considering the optimal current difference effect on a unidirectional single lane highway. Heterogeneous traffic consisting of low- and high-sensitivity vehicles is modeled and their impact on stability of mixed traffic flow has been examined through linear stability analysis. The stability of flow is investigated in five distinct regions of the neutral stability diagram corresponding to the amount of higher sensitivity vehicles present on road. In order to investigate the propagating behavior of density waves non linear analysis is performed and near the critical point, the kink antikink soliton is obtained by driving mKdV equation. The effect of fraction parameter corresponding to high sensitivity vehicles is investigated and the results indicates that the stability rise up due to the fraction parameter. The theoretical findings are verified via direct numerical simulation.

  2. An integrated molecular docking and rescoring method for predicting the sensitivity spectrum of various serine hydrolases to organophosphorus pesticides.

    PubMed

    Yang, Ling-Ling; Yang, Xiao; Li, Guo-Bo; Fan, Kai-Ge; Yin, Peng-Fei; Chen, Xiang-Gui

    2016-04-01

    The enzymatic chemistry method is currently the most widely used method for the rapid detection of organophosphorus (OP) pesticides, but the enzymes used, such as cholinesterases, lack sufficient sensitivity to detect low concentrations of OP pesticides present in given samples. Serine hydrolase is considered an ideal enzyme source in seeking high-sensitivity enzymes used for OP pesticide detection. However, it is difficult to systematically evaluate sensitivities of various serine hydrolases to OP pesticides by in vitro experiments. This study aimed to establish an in silico method to predict the sensitivity spectrum of various serine hydrolases to OP pesticides. A serine hydrolase database containing 219 representative serine hydrolases was constructed. Based on this database, an integrated molecular docking and rescoring method was established, in which the AutoDock Vina program was used to produce the binding poses of OP pesticides to various serine hydrolases and the ID-Score method developed recently by us was adopted as a rescoring method to predict their binding affinities. In retrospective case studies, this method showed good performance in predicting the sensitivities of known serine hydrolases to two OP pesticides: paraoxon and diisopropyl fluorophosphate. The sensitivity spectrum of the 219 collected serine hydrolases to 37 commonly used OP pesticides was finally obtained using this method. Overall, this study presented a promising in silico tool to predict the sensitivity spectrum of various serine hydrolases to OP pesticides, which will help in finding high-sensitivity serine hydrolases for OP pesticide detection. © 2015 Society of Chemical Industry.

  3. Non-destructive Testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    NASA Technical Reports Server (NTRS)

    Lu, D. F.; Fan, Chang-Xin; Ruan, J. Z.; Han, S. G.; Wong, K. W.; Sun, G. F.

    1995-01-01

    A SQUID is the most sensitive device to detect change in magnetic field. A nondestructive testing (NDT) device using high temperature SQUID's and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUID's. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology.

  4. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    NASA Astrophysics Data System (ADS)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-08-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R&D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion.

  5. CMOS Amperometric ADC With High Sensitivity, Dynamic Range and Power Efficiency for Air Quality Monitoring.

    PubMed

    Li, Haitao; Boling, C Sam; Mason, Andrew J

    2016-08-01

    Airborne pollutants are a leading cause of illness and mortality globally. Electrochemical gas sensors show great promise for personal air quality monitoring to address this worldwide health crisis. However, implementing miniaturized arrays of such sensors demands high performance instrumentation circuits that simultaneously meet challenging power, area, sensitivity, noise and dynamic range goals. This paper presents a new multi-channel CMOS amperometric ADC featuring pixel-level architecture for gas sensor arrays. The circuit combines digital modulation of input currents and an incremental Σ∆ ADC to achieve wide dynamic range and high sensitivity with very high power efficiency and compact size. Fabricated in 0.5 [Formula: see text] CMOS, the circuit was measured to have 164 dB cross-scale dynamic range, 100 fA sensitivity while consuming only 241 [Formula: see text] and 0.157 [Formula: see text] active area per channel. Electrochemical experiments with liquid and gas targets demonstrate the circuit's real-time response to a wide range of analyte concentrations.

  6. Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation using Superconducting Tunnel Junctions with Radio-Frequency Single-Electron Transistors

    NASA Technical Reports Server (NTRS)

    Stevenson, T. R.; Hsieh, W.-T.; Li, M. J.; Stahle, C. M.; Wollack, E. J.; Schoelkopf, R. J.; Krebs, Carolyn (Technical Monitor)

    2002-01-01

    The science drivers for the SPIRIT/SPECS missions demand sensitive, fast, compact, low-power, large-format detector arrays for high resolution imaging and spectroscopy in the far infrared and submillimeter. Detector arrays with 10,000 pixels and sensitivity less than 10(exp 20)-20 W/Hz(exp 20)0.5 are needed. Antenna-coupled superconducting tunnel junction detectors with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique when forming arrays. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

  7. Incremental value of copeptin to highly sensitive cardiac Troponin I for rapid rule-out of myocardial infarction.

    PubMed

    Wildi, Karin; Zellweger, Christa; Twerenbold, Raphael; Jaeger, Cedric; Reichlin, Tobias; Haaf, Philip; Faoro, Jonathan; Giménez, Maria Rubini; Fischer, Andreas; Nelles, Berit; Druey, Sophie; Krivoshei, Lian; Hillinger, Petra; Puelacher, Christian; Herrmann, Thomas; Campodarve, Isabel; Rentsch, Katharina; Steuer, Stephan; Osswald, Stefan; Mueller, Christian

    2015-01-01

    The incremental value of copeptin, a novel marker of endogenous stress, for rapid rule-out of non-ST-elevation myocardial infarction (NSTEMI) is unclear when sensitive or even high-sensitivity cardiac troponin cTn (hs-cTn) assays are used. In an international multicenter study we evaluated 1929 consecutive patients with symptoms suggestive of acute myocardial infarction (AMI). Measurements of copeptin, three sensitive and three hs-cTn assays were performed at presentation in a blinded fashion. The final diagnosis was adjudicated by two independent cardiologists using all clinical information including coronary angiography and levels of hs-cTnT. The incremental value in the diagnosis of NSTEMI was quantified using four outcome measures: area under the receiver-operating characteristic curve (AUC), integrated discrimination improvement (IDI), sensitivity and negative predictive value (NPV). Early presenters (< 4h since chest pain onset) were a pre-defined subgroup. NSTEMI was the adjudicated final diagnosis in 358 (18.6%) patients. As compared to the use of cTn alone, copeptin significantly increased AUC for two (33%) and IDI (between 0.010 and 0.041 (all p < 0.01)), sensitivity and NPV for all six cTn assays (100%); NPV to 96-99% when the 99 th percentile of the respective cTnI assay was combined with a copeptin level of 9 pmol/l (all p < 0.01). The incremental value in early presenters was similar to that of the overall cohort. When used for rapid rule-out of NSTEM in combination with sensitive or hs-cTnI assays, copeptin provides a numerically small, but statistically and likely also clinically significant incremental value. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Analysis and amelioration about the cross-sensitivity of a high resolution MOEMS accelerometer based on diffraction grating

    NASA Astrophysics Data System (ADS)

    Lu, Qianbo; Bai, Jian; Wang, Kaiwei; Lou, Shuqi; Jiao, Xufen; Han, Dandan

    2016-10-01

    Cross-sensitivity is a crucial parameter since it detrimentally affect the performance of an accelerometer, especially for a high resolution accelerometer. In this paper, a suite of analytical and finite-elements-method (FEM) models for characterizing the mechanism and features of the cross-sensitivity of a single-axis MOEMS accelerometer composed of a diffraction grating and a micromachined mechanical sensing chip are presented, which have not been systematically investigated yet. The mechanism and phenomena of the cross-sensitivity of this type MOEMS accelerometer based on diffraction grating differ quite a lot from the traditional ones owing to the identical sensing principle. By analyzing the models, some ameliorations and the modified design are put forward to suppress the cross-sensitivity. The modified design, achieved by double sides etching on a specific double-substrate-layer silicon-on-insulator (SOI) wafer, is validated to have a far smaller cross-sensitivity compared with the design previously reported in the literature. Moreover, this design can suppress the cross-sensitivity dramatically without compromising the acceleration sensitivity and resolution.

  9. Contrast-enhanced swallow study sensitivity for anastomotic leak detection in post-esophagectomy patients.

    PubMed

    Mejía-Rivera, S; Pérez-Marroquín, S A; Cortés-González, R; Medina-Franco, H

    2018-03-07

    Esophagectomy is a highly invasive surgery and one of its postoperative complications is anastomotic leakage, occurring in 53% of cases. The aim of the present study was to determine the sensitivity of the contrast-enhanced swallow study as a method for diagnosing anastomotic leak in patients that underwent esophagectomy. The present retrospective study included the case records of patients that underwent esophagectomy with reconstruction and cervical anastomosis at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán within the time frame of January 1, 2000 and May 31, 2006. Demographic, clinical, and laboratory data emphasizing clinical and radiographic anastomotic leak detection were identified. Descriptive statistics were carried out and contrast-enhanced swallow study sensitivity for diagnosing leakage was calculated. Seventy patients were included in the analysis. The mean age of the patients was 50.6 years, 51 of the patients were men (72.86%), and 19 were women (27.14%). Indications for surgery were benign lesion in 29 patients (41.4%) and malignant lesion in 41 (58.6%). A total of 44.3% of the patients presented with a comorbidity, with diabetes mellitus and high blood pressure standing out. Thirty patients (42.85%) presented with anastomotic leak. Contrast-enhanced swallow study sensitivity for leak detection was 43.33%. The diagnostic sensitivity of the contrast-enhanced swallow study was very low. Therefore, we recommend the discontinuation of its routine use as a method for diagnosing anastomotic leaks. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  10. New On-Orbit Sensitivity Calibrationfor All STIS Echelle Modes

    NASA Astrophysics Data System (ADS)

    Aloisi, Alessandra; Bohlin, Ralph; Quijano, Jessica Kim

    2007-01-01

    On-orbit sensitivities for the 32 medium- and high-resolution STIS echelle secondarymodes were determined for the rst time using observations of the fundamental DAwhite dwarf standard star G191-B2B. Revised on-orbit sensitivities for the 12 mediumandhigh-resolution echelle prime modes based on observations of the same standardstar are also presented. We review the procedures and assumptions used to derive theadopted throughputs and implement them into the pipeline.

  11. Protein detection system

    DOEpatents

    Fruetel, Julie A [Livermore, CA; Fiechtner, Gregory J [Bethesda, MD; Kliner, Dahv A. V. [San Ramon, CA; McIlroy, Andrew [Livermore, CA

    2009-05-05

    The present embodiment describes a miniature, microfluidic, absorption-based sensor to detect proteins at sensitivities comparable to LIF but without the need for tagging. This instrument utilizes fiber-based evanescent-field cavity-ringdown spectroscopy, in combination with faceted prism microchannels. The combination of these techniques will increase the effective absorption path length by a factor of 10.sup.3 to 10.sup.4 (to .about.1-m), thereby providing unprecedented sensitivity using direct absorption. The coupling of high-sensitivity absorption with high-performance microfluidic separation will enable real-time sensing of biological agents in aqueous samples (including aerosol collector fluids) and will provide a general method with spectral fingerprint capability for detecting specific bio-agents.

  12. Utility of screening ultrasound after first febrile UTI among patients with clinically significant vesicoureteral reflux.

    PubMed

    Massanyi, Eric Z; Preece, Janae; Gupta, Angela; Lin, Susan M; Wang, Ming-Hsien

    2013-10-01

    To assess the sensitivity and negative predictive value (NPV) of screening renal and bladder ultrasound (RBUS) after initial febrile urinary tract infection (UTI) among patients with clinically significant vesicoureteral reflux (VUR). A retrospective review was performed of all children <2 years of age who presented with a febrile UTI between 2004 and 2011. The sensitivity and NPV of initial RBUS was calculated among patients who were found to have high-grade (IV-V) VUR. Additionally, initial RBUS among patients with evidence of photopenia on dimercaptosuccinic acid (DMSA) scan or who underwent surgical intervention were reviewed. One hundred forty-four patients with febrile UTI were identified; available RBUS, voiding cystourethrogram (VCUG), and DMSA results for each kidney were reviewed. One hundred fifty-eight kidneys had evidence of VUR on VCUG, and initial RBUS demonstrated abnormality in 25 (sensitivity 0.17). Forty-five kidneys had high-grade VUR and RBUS revealed abnormality in 16 (sensitivity 0.36). One hundred seventy-eight kidneys had no evidence of abnormality on initial RBUS, and 136 (76%) were found to have VUR (NPV 0.24), of which 31 had high-grade VUR (NPV 0.83). Seven kidneys had scarring on DMSA and initial RBUS was normal in 4 (57%). Twelve of 19 patients (63%) who eventually underwent surgical intervention had a normal initial RBUS. RBUS has poor sensitivity and NPV for detecting high-grade VUR in patients <2 years who present with a febrile UTI. A significant number of patients who were diagnosed with high-grade VUR, renal scarring, or underwent surgical correction of VUR had a negative screening RBUS. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. LASER BIOLOGY AND MEDICINE: Application of tunable diode lasers for a highly sensitive analysis of gaseous biomarkers in exhaled air

    NASA Astrophysics Data System (ADS)

    Stepanov, E. V.; Milyaev, Varerii A.

    2002-11-01

    The application of tunable diode lasers for a highly sensitive analysis of gaseous biomarkers in exhaled air in biomedical diagnostics is discussed. The principle of operation and the design of a laser analyser for studying the composition of exhaled air are described. The results of detection of gaseous biomarkers in exhaled air, including clinical studies, which demonstrate the diagnostic possibilities of the method, are presented.

  14. Re-scan confocal microscopy: scanning twice for better resolution

    PubMed Central

    De Luca, Giulia M.R.; Breedijk, Ronald M.P.; Brandt, Rick A.J.; Zeelenberg, Christiaan H.C.; de Jong, Babette E.; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A.; Stallinga, Sjoerd; Manders, Erik M.M.

    2013-01-01

    We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required. PMID:24298422

  15. Method and apparatus for detection of charge on ions and particles

    DOEpatents

    Fuerstenau, Stephen Douglas; Soli, George Arthur

    2002-01-01

    The present invention provides a tessellated array detector with charge collecting plate (or cup) electrode pixels and amplifying circuitry integrated into each pixel making it sensitive to external electrostatic charge; a micro collector/amplifier pixel design possessing a small capacitance to ensure a high charge to voltage signal conversion for low noise/high sensitivity operation; a micro-fabricated array of such pixels to create a useful macroscopic target area for ion and charged particle collection.

  16. Fundamentals of nuclear medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alazraki, N.P.; Mishkin, F.S.

    1988-01-01

    The book begins with basic science and statistics relevant to nuclear medicine, and specific organ systems are addressed in separate chapters. A section of the text also covers imaging of groups of disease processes (eg, trauma, cancer). The authors present a comparison between nuclear medicine techniques and other diagnostic imaging studies. A table is given which comments on sensitivities and specificities of common nuclear medicine studies. The sensitivities and specificities are categorized as very high, high, moderate, and so forth.

  17. Highly sensitive and quantitative evaluation of the EGFR T790M mutation by nanofluidic digital PCR.

    PubMed

    Iwama, Eiji; Takayama, Koichi; Harada, Taishi; Okamoto, Isamu; Ookubo, Fumihiko; Kishimoto, Junji; Baba, Eishi; Oda, Yoshinao; Nakanishi, Yoichi

    2015-08-21

    The mutation of T790M in EGFR is a major mechanism of resistance to treatment with EGFR-TKIs. Only qualitative detection (presence or absence) of T790M has been described to date, however. Digital PCR (dPCR) analysis has recently been applied to the quantitative detection of target molecules in cancer with high sensitivity. In the present study, 25 tumor samples (13 obtained before and 12 after EGFR-TKI treatment) from 18 NSCLC patients with activating EGFR mutations were evaluated for T790M with dPCR. The ratio of the number of T790M alleles to that of activating mutation alleles (T/A) was determined. dPCR detected T790M in all 25 samples. Although T790M was present in all pre-TKI samples from 13 patients, 10 of these patients had a low T/A ratio and manifested substantial tumor shrinkage during treatment with EGFR-TKIs. In six of seven patients for whom both pre- and post-TKI samples were available, the T/A ratio increased markedly during EGFR-TKI treatment. Highly sensitive dPCR thus detected T790M in all NSCLC patients harboring activating EGFR mutations whether or not they had received EGFR-TKI treatment. Not only highly sensitive but also quantitative detection of T790M is important for evaluation of the contribution of T790M to EGFR-TKI resistance.

  18. Development and characterization of high-resolution neutron pixel detectors based on Timepix read-out chips

    NASA Astrophysics Data System (ADS)

    Krejci, F.; Zemlicka, J.; Jakubek, J.; Dudak, J.; Vavrik, D.; Köster, U.; Atkins, D.; Kaestner, A.; Soltes, J.; Viererbl, L.; Vacik, J.; Tomandl, I.

    2016-12-01

    Using a suitable isotope such as 6Li and 10B semiconductor hybrid pixel detectors can be successfully adapted for position sensitive detection of thermal and cold neutrons via conversion into energetic light ions. The adapted devices then typically provides spatial resolution at the level comparable to the pixel pitch (55 μm) and sensitive area of about few cm2. In this contribution, we describe further progress in neutron imaging performance based on the development of a large-area hybrid pixel detector providing practically continuous neutron sensitive area of 71 × 57 mm2. The measurements characterising the detector performance at the cold neutron imaging instrument ICON at PSI and high-flux imaging beam-line Neutrograph at ILL are presented. At both facilities, high-resolution high-contrast neutron radiography with the newly developed detector has been successfully applied for objects which imaging were previously difficult with hybrid pixel technology (such as various composite materials, objects of cultural heritage etc.). Further, a significant improvement in the spatial resolution of neutron radiography with hybrid semiconductor pixel detector based on the fast read-out Timepix-based detector is presented. The system is equipped with a thin planar 6LiF convertor operated effectively in the event-by-event mode enabling position sensitive detection with spatial resolution better than 10 μm.

  19. High-sensitivity refractive index sensor based on large-angle tilted fiber grating with carbon nanotube deposition

    NASA Astrophysics Data System (ADS)

    Badmos, Abdulyezir A.; Sun, Qizhen; Yan, Zhijun; Arif, Raz N.; Zhang, Junxi; Rozhin, Alex; Zhang, Lin

    2016-04-01

    This paper presents a highly sensitive ambient refractive index (RI) sensor based on 81° tilted fiber grating (81°-TFG) structure UV-inscribed in standard telecom fiber (62.5μm cladding radius) with carbon nanotube (CNT) overlay deposition. The sensing mechanism is based on the ability of CNT to induce change in transmitted optical power and the high sensitivity of 81°-TFG to ambient refractive index. The thin CNT film with high refractive index enhances the cladding modes of the TFG, resulting in the significant interaction between the propagating light and the surrounding medium. Consequently, the surrounding RI change will induce not only the resonant wavelength shift but also the power intensity change of the attenuation band in the transmission spectrum. Result shows that the change in transmitted optical power produces a corresponding linear reduction in intensity with increment in RI values. The sample shows high sensitivities of 207.38nm/RIU, 241.79nm/RIU at RI range 1.344-1.374 and 113.09nm/RIU, 144.40nm/RIU at RI range 1.374-1.392 (for X-pol and Y-pol respectively). It also shows power intensity sensitivity of 65.728dBm/RIU and 45.898 (for X-pol and Y-pol respectively). The low thermal sensitivity property of the 81°-TFG offers reduction in thermal cross-sensitivity and enhances specificity of the sensor.

  20. Sunflower seeds as eliciting agents of Compositae dermatitis.

    PubMed

    Paulsen, Evy; El-Houri, Rime B; Andersen, Klaus E; Christensen, Lars P

    2015-03-01

    Sunflowers may cause dermatitis because of allergenic sesquiterpene lactones (SLs). Contact sensitization to sunflower seeds has also been reported, but the allergens are unknown. To analyse sunflower seeds for the presence of SLs and to assess the prevalence of sunflower sensitization in Compositae-allergic individuals. Sunflower-sensitive patients were identified by aimed patch testing. A dichloromethane extract of whole sunflower seeds was analysed by liquid chromatography-mass spectrometry and high-performance liquid chromatography. The prevalence of sensitivity to sunflower in Compositae-allergic individuals was 56%. A solvent wash of whole sunflower seeds yielded an extract containing SLs, the principal component tentatively being identified as argophyllin A or B, other SLs being present in minute amounts. The concentration of SLs on the sunflower seeds is considered high enough to elicit dermatitis in sensitive persons, and it seems appropriate to warn Compositae-allergic subjects against handling sunflower seeds. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Sensitivity-Enhanced Wearable Active Voiceprint Sensor Based on Cellular Polypropylene Piezoelectret.

    PubMed

    Li, Wenbo; Zhao, Sheng; Wu, Nan; Zhong, Junwen; Wang, Bo; Lin, Shizhe; Chen, Shuwen; Yuan, Fang; Jiang, Hulin; Xiao, Yongjun; Hu, Bin; Zhou, Jun

    2017-07-19

    Wearable active sensors have extensive applications in mobile biosensing and human-machine interaction but require good flexibility, high sensitivity, excellent stability, and self-powered feature. In this work, cellular polypropylene (PP) piezoelectret was chosen as the core material of a sensitivity-enhanced wearable active voiceprint sensor (SWAVS) to realize voiceprint recognition. By virtue of the dipole orientation control method, the air layers in the piezoelectret were efficiently utilized, and the current sensitivity was enhanced (from 1.98 pA/Hz to 5.81 pA/Hz at 115 dB). The SWAVS exhibited the superiorities of high sensitivity, accurate frequency response, and excellent stability. The voiceprint recognition system could make correct reactions to human voices by judging both the password and speaker. This study presented a voiceprint sensor with potential applications in noncontact biometric recognition and safety guarantee systems, promoting the progress of wearable sensor networks.

  2. Gene expression analysis using a highly sensitive DNA microarray for colorectal cancer screening.

    PubMed

    Koga, Yoshikatsu; Yamazaki, Nobuyoshi; Takizawa, Satoko; Kawauchi, Junpei; Nomura, Osamu; Yamamoto, Seiichiro; Saito, Norio; Kakugawa, Yasuo; Otake, Yosuke; Matsumoto, Minori; Matsumura, Yasuhiro

    2014-01-01

    Half of all patients with small, right-sided, non-metastatic colorectal cancer (CRC) have negative results for the fecal occult blood test (FOBT). In the present study, the usefulness of CRC screening with a highly sensitive DNA microarray was evaluated in comparison with that by FOBT using fecal samples. A total of 53 patients with CRC and 61 healthy controls were divided into "training" and "validation sets". For the gene profiling, total RNA extracted from 0.5 g of feces was hybridized to a highly sensitive DNA chip. The expressions of 43 genes were significantly higher in the patients with CRC than in healthy controls (p<0.05). In the training set, the sensitivity and specificity of the DNA chip assay using six genes were 85.4% and 85.2%, respectively. On the other hand, in the validation set, the sensitivity and specificity of the DNA chip assay were 85.2% and 85.7%, respectively. The sensitivities of the DNA chip assay were higher than those of FOBT in cases of the small, right-sided, early-CRC, tumor invading up to the muscularis propria (i.e. surface tumor) subgroups. In particular, the sensitivities of the DNA chip assay in the surface tumor and early-CRC subgroups were significantly higher than those of FOBT (p=0.023 and 0.019, respectively.). Gene profiling assay using a highly sensitive DNA chip was more effective than FOBT at detecting patients with small, right-sided, surface tumor, and early-stage CRC.

  3. Interpersonal sensitivity and functioning impairment in youth at ultra-high risk for psychosis.

    PubMed

    Masillo, A; Valmaggia, L R; Saba, R; Brandizzi, M; Lindau, J F; Solfanelli, A; Curto, M; Narilli, F; Telesforo, L; Kotzalidis, G D; Di Pietro, D; D'Alema, M; Girardi, P; Fiori Nastro, P

    2016-01-01

    A personality trait that often elicits poor and uneasy interpersonal relationships is interpersonal sensitivity. The aim of the present study was to explore the relationship between interpersonal sensitivity and psychosocial functioning in individuals at ultra-high risk for psychosis as compared to help-seeking individuals who screened negative for an ultra-high risk of psychosis. A total sample of 147 adolescents and young adult who were help seeking for emerging mental health problems participated in the study. The sample was divided into two groups: 39 individuals who met criteria for an ultra-high-risk mental state (UHR), and 108 (NS). The whole sample completed the Interpersonal Sensitivity Measure (IPSM) and the Global Functioning: Social and Role Scale (GF:SS; GF:RS). Mediation analysis was used to explore whether attenuated negative symptoms mediated the relationship between interpersonal sensitivity and social functioning. Individuals with UHR state showed higher IPSM scores and lower GF:SS and GF:RS scores than NS participants. A statistically negative significant correlation between two IPSM subscales (Interpersonal Awareness and Timidity) and GF:SS was found in both groups. Our results also suggest that the relationship between the aforementioned aspects of interpersonal sensitivity and social functioning was not mediated by negative prodromal symptoms. This study suggests that some aspects of interpersonal sensitivity were associated with low level of social functioning. Assessing and treating interpersonal sensitivity may be a promising therapeutic target to improve social functioning in young help-seeking individuals.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Liang; Dong, Dongdong; Qiao, Keke

    Wearable and sensitive photodetectors (PDs) have been demonstrated based on a blend film of PbS quantum dots (QDs) and QDs modified multiwalled carbon nanotubes (MWCNTs). Owing to the synergetic effect from high light sensitivity of PbS QDs and excellent conductive and mechanical properties of MWCNTs, the blend PDs show high sensitivity and flexibility performance: device responsivity and detectivity reach 583 mA/W and 3.25 × 10{sup 12 }Jones, respectively, and could stand large number (at least 10 000 cycles) and wide angle (up to 80°) bending. Furthermore, the wearable and sensitive PDs have been applied to measure the heart rate in both red and near infraredmore » (NIR) ranges. The presented PDs are expected to work as sensor candidates in integrated electronic skin.« less

  5. High sensitivity rotation sensing based on tunable asymmetrical double-ring structure

    NASA Astrophysics Data System (ADS)

    Gu, Hong; Liu, Xiaoqing

    2017-05-01

    A very high sensitivity rotation sensor comprising a tunable asymmetrical double-ring structure (TADRS) coupled by a 3 × 3 coupler is presented. The phase difference caused by the TADRS between the counter-propagating waves is derived and discussed. At the resonant frequency, the phase shift difference has the maximum value when the light power in one cavity is amplified about 1.85 times while attenuated 79% in another. The maximum sensitivity of the TADRS sensor is two times larger than that of a single-ring structure. An experimental system is designed to verify the theoretical results and introduce the method of demodulation. The rotation sensor based on TADRS can enhance the sensitivity of the detection of the angular velocity by more than three orders of magnitude.

  6. Anxiety sensitivity: the role of conscious awareness and selective attentional bias to physical threat.

    PubMed

    Hunt, Caroline; Keogh, Edmund; French, Christopher C

    2006-08-01

    Selective attentional biases were examined amongst individuals varying in levels of physical anxiety sensitivity. The dot-probe paradigm was used to examine attention towards anxiety symptomatology, social threat and positive words. Stimuli were presented above (unmasked) and below (masked) the level of conscious awareness. High physical anxiety sensitivity was associated with attentional vigilance for anxiety symptomatology words in both unmasked and masked conditions. For positive words, however, those high in anxiety sensitivity were found to avoid such stimuli when they were masked, whereas they exhibited a relative vigilance when unmasked. If the differences between awareness conditions are reliable, then the impact of the automatic vigilance for threat might be modified by conscious attempts to direct attention towards other types of stimuli. (c) 2006 APA, all rights reserved

  7. Analysis of different anthropometric indicators in the detection of high blood pressure in school adolescents: a cross-sectional study with 8295 adolescents.

    PubMed

    Christofaro, Diego G D; Farah, Breno Q; Vanderlei, Luiz Carlos M; Delfino, Leandro D; Tebar, William R; Barros, Mauro Virgílio G de; Ritti-Dias, Raphael M

    High blood pressure is strongly associated with obesity in different populations. However, it is unclear whether different anthropometric indicators of obesity can satisfactorily predict high blood pressure in the school setting. This study evaluated the sensitivity and specificity of body mass index, waist circumference, and waist to height ratio in the detection of high blood pressure in adolescents. The sample consisted of 8295 adolescents aged 10-17 years. Weight was measured using a digital scale, height with a stadiometer, and waist circumference using a tape measure. Blood pressure was measured by an automatic blood pressure measuring device. ROC curves were used for the analysis of sensitivity and specificity of the three anthropometric indices in identifying high blood pressure. Binary Logistic Regression was used to assess the association of body mass index, waist circumference, and waist to height ratio with high blood pressure. Low values of sensitivity were observed for body mass index (0.35), waist circumference (0.37), and waist to height ratio (0.31) and high values of specificity for body mass index (0.86), waist circumference (0.82), and waist to height ratio (0.83) in the detection of high blood pressure. An association was observed between adolescents classified with high body mass index (OR=3.57 [95% CI=3.10-4.10]), waist cirumference (OR=3.24 [95% CI=2.83-3.72]), and waist to height ratio (OR=2.94 [95% CI=2.54-3.40]) with high blood pressure. Body mass index, waist circumference, and waist to height ratio presented low sensitivity to identify adolescents with high blood pressure. However, adolescents classified with high body mass index, waist circumference, and waist to height ratio demonstrated a high association of presenting high blood pressure. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  8. Dietary supplementation with fish oil prevents high fat diet-induced enhancement of sensitivity to the locomotor stimulating effects of cocaine in adolescent female rats.

    PubMed

    Serafine, Katherine M; Labay, Caitlin; France, Charles P

    2016-08-01

    Eating a diet high in fat can lead to obesity, chronic metabolic disease, and increased inflammation in both the central and peripheral nervous systems. Dietary supplements that are high in omega-3 polyunsaturated fatty acids can reduce or prevent these negative health consequences in rats. Eating high fat chow also increases the sensitivity of rats to behavioral effects of drugs acting on dopamine systems (e.g., cocaine), and this effect is greatest in adolescent females. The present experiment tested the hypothesis that dietary supplementation with fish oil prevents high fat chow induced increases in sensitivity to cocaine in adolescent female rats. Female Sprague-Dawley rats (post-natal day 25-27) ate standard laboratory chow (5.7% fat), high fat chow (34.4% fat), or high fat chow supplemented with fish oil (20% w/w). Cocaine dose dependently (1-17.8mg/kg) increased locomotion and induced sensitization across 6 weeks of once-weekly testing in all rats; however, these effects were greatest in rats eating high fat chow. Dietary supplementation with fish oil prevented enhanced locomotion and sensitization in rats eating high fat chow. There were no differences in inflammatory markers in plasma or the hypothalamus among dietary conditions. These results demonstrate that dietary supplementation with fish oil can prevent high fat diet-induced sensitization to cocaine, but they fail to support the view that these effects are due to changes in proinflammatory cytokines. These data add to a growing literature on the relationship between diet and drug abuse and extend the potential health benefits of fish oil to stimulant drug abuse prevention. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Dietary supplementation with fish oil prevents high fat diet-induced enhancement of sensitivity to the locomotor stimulating effects of cocaine in adolescent female rats

    PubMed Central

    Serafine, Katherine M.; Labay, Caitlin; France, Charles P.

    2016-01-01

    BACKGROUND Eating a diet high in fat can lead to obesity, chronic metabolic disease, and increased inflammation in both the central and peripheral nervous systems. Dietary supplements that are high in omega-3 polyunsaturated fatty acids can reduce or prevent these negative health consequences in rats. Eating high fat chow also increases the sensitivity of rats to behavioral effects of drugs acting on dopamine systems (e.g., cocaine), and this effect is greatest in adolescent females. METHODS The present experiment tested the hypothesis that dietary supplementation with fish oil prevents high fat chow induced increases in sensitivity to cocaine in adolescent female rats. Female Sprague-Dawley rats (post-natal day 25–27) ate standard laboratory chow (5.7% fat), high fat chow (34.4% fat), or high fat chow supplemented with fish oil (20% w/w). Cocaine dose dependently (1–17.8 mg/kg) increased locomotion and induced sensitization across 6 weeks of once-weekly testing in all rats; however, these effects were greatest in rats eating high fat chow. RESULTS Dietary supplementation with fish oil prevented enhanced locomotion and sensitization in rats eating high fat chow. There were no differences in inflammatory markers in plasma or the hypothalamus among dietary conditions. CONCLUSIONS These results demonstrate that dietary supplementation with fish oil can prevent high fat diet-induced sensitization to cocaine, but they fail to support the view that these effects are due to changes in proinflammatory cytokines. These data add to a growing literature on the relationship between diet and drug abuse and extend the potential health benefits of fish oil to stimulant drug abuse prevention. PMID:27242289

  10. Design and analysis of a silicon-based antiresonant reflecting optical waveguide chemical sensor

    NASA Astrophysics Data System (ADS)

    Remley, Kate A.; Weisshaar, Andreas

    1996-08-01

    The design of a silicon-based antiresonant reflecting optical waveguide (ARROW) chemical sensor is presented, and its theoretical performance is compared with that of a conventional structure. The use of an ARROW structure permits incorporation of a thick guiding region for efficient coupling to a single-mode fiber. A high-index overlay is added to fine tune the sensitivity of the ARROW chemical sensor. The sensitivity of the sensor is presented, and design trade-offs are discussed.

  11. Sensory-processing sensitivity in social anxiety disorder: Relationship to harm avoidance and diagnostic subtypes

    PubMed Central

    Hofmann, Stefan G.; Bitran, Stella

    2007-01-01

    Sensory-processing sensitivity is assumed to be a heritable vulnerability factor for shyness. The present study is the first to examine sensory-processing sensitivity among individuals with social anxiety disorder. The results showed that the construct is separate from social anxiety, but it is highly correlated with harm avoidance and agoraphobic avoidance. Individuals with a generalized subtype of social anxiety disorder reported higher levels of sensory-processing sensitivity than individuals with a non-generalized subtype. These preliminary findings suggest that sensory-processing sensitivity is uniquely associated with the generalized subtype of social anxiety disorder. Recommendations for future research are discussed. PMID:17241764

  12. Can Anxiety Tested in the Elevated Plus-maze Be Related to Nociception Sensitivity in Adult Male Rats?

    PubMed

    Pometlová, Marie; Yamamotová, Anna; Nohejlová, Kateryna; Šlamberová, Romana

    Methamphetamine (MA) is one of the most addictive psychostimulant drugs with a high potential for abuse. Our previous studies demonstrated that MA administered to pregnant rats increases pain sensitivity and anxiety in their adult offspring and makes them more sensitive to acute administration of the same drug in adulthood. Because individuals can differ considerably in terms of behaviour and physiology, such as rats that do not belong in some characteristics (e.g. anxiety) to average, can be described as low-responders or high-responders, are then more or less sensitive to pain. Therefore, prenatally MA-exposed adult male rats treated in adulthood with a single dose of MA (1 mg/ml/kg) or saline (1 ml/kg) were tested in the present study. We examined the effect of acute MA treatment on: (1) the anxiety in the Elevated plus-maze (EPM) test and memory in EPM re-test; (2) nociception sensitivity in the Plantar test; (3) the correlation between the anxiety, memory and the nociception. Our results demonstrate that: (1) MA has an anxiogenic effect on animals prenatally exposed to the same drug in the EPM; (2) all the differences induced by acute MA treatment disappeared within the time of 48 hours; (3) there was no effect of MA on nociception per se, but MA induced higher anxiety in individuals less sensitive to pain than in animals more sensitive to pain. In conclusion, the present study demonstrates unique data showing association between anxiety and nociceptive sensitivity of prenatally MA-exposed rats that is induced by acute drug administration.

  13. Non-destructive testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, D.F.; Fan, C.; Ruan, J.Z.

    1994-12-31

    A SQUID is the most sensitive device to detect change in magnetic field. A non-destructive testing (NDT) device using high temperature SQUIDs and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUIDs. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDTmore » device will have a significant impact on metal corrosion or crack detection technology.« less

  14. L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array

    NASA Astrophysics Data System (ADS)

    Titus, Charles J.; Baker, Michael L.; Lee, Sang Jun; Cho, Hsiao-Mei; Doriese, William B.; Fowler, Joseph W.; Gaffney, Kelly; Gard, Johnathon D.; Hilton, Gene C.; Kenney, Chris; Knight, Jason; Li, Dale; Marks, Ronald; Minitti, Michael P.; Morgan, Kelsey M.; O'Neil, Galen C.; Reintsema, Carl D.; Schmidt, Daniel R.; Sokaras, Dimosthenis; Swetz, Daniel S.; Ullom, Joel N.; Weng, Tsu-Chien; Williams, Christopher; Young, Betty A.; Irwin, Kent D.; Solomon, Edward I.; Nordlund, Dennis

    2017-12-01

    We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.

  15. High sensitivity gas sensor based on high-Q suspended polymer photonic crystal nanocavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clevenson, Hannah, E-mail: hannahac@mit.edu; Desjardins, Pierre; Gan, Xuetao

    2014-06-16

    We present high-sensitivity, multi-use optical gas sensors based on a one-dimensional photonic crystal cavity. These devices are implemented in versatile, flexible polymer materials which swell when in contact with a target gas, causing a measurable cavity length change. This change causes a shift in the cavity resonance, allowing precision measurements of gas concentration. We demonstrate suspended polymer nanocavity sensors and the recovery of sensors after the removal of stimulant gas from the system. With a measured quality factor exceeding 10{sup 4}, we show measurements of gas concentration as low as 600 parts per million (ppm) and an experimental sensitivity ofmore » 10 ppm; furthermore, we predict detection levels in the parts-per-billion range for a variety of gases.« less

  16. Imaging in the evaluation of renovascular disease

    PubMed Central

    Roebuck, Derek J.; McLaren, Clare A.; Marks, Stephen D.

    2009-01-01

    Renovascular disease (RVD) is an important cause of hypertension in children, as it often is amenable to potentially curative treatment. Imaging aimed at finding RVD therefore needs to have high sensitivity so as not to miss important findings. Digital subtraction angiography is the gold standard investigation. Doppler ultrasonography, computed tomography (CT) angiography and magnetic resonance (MR) angiography can all be helpful, but none has, at present, high enough sensitivity to rule out RVD in a child with a suggestion of that diagnosis. PMID:19856000

  17. The Georgia Tech High Sensitivity Microwave Measurement System

    NASA Technical Reports Server (NTRS)

    Deboer, David R.; Steffes, Paul G.

    1996-01-01

    As observations and models of the planets become increasingly more accurate and sophisticated, the need for highly accurate laboratory measurements of the microwave properties of the component gases present in their atmospheres become ever more critical. This paper describes the system that has been developed at Georgia Tech to make these measurements at wavelengths ranging from 13.3 cm to 1.38 cm with a sensitivity of 0.05 dB/km at the longest wavelength and 0.6 db/km at the shortest wavelength.

  18. Screening for cognitive dysfunction in ALS: validation of the Edinburgh Cognitive and Behavioural ALS Screen (ECAS) using age and education adjusted normative data.

    PubMed

    Pinto-Grau, Marta; Burke, Tom; Lonergan, Katie; McHugh, Caroline; Mays, Iain; Madden, Caoifa; Vajda, Alice; Heverin, Mark; Elamin, Marwa; Hardiman, Orla; Pender, Niall

    2017-02-01

    Cognitive and behavioural changes are an important aspect in Amyotrophic Lateral Sclerosis (ALS). The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) briefly assesses these changes in ALS. To validate the ECAS against a standardised neuropsychological battery and assess its sensitivity and specificity using age and education adjusted cut-off scores. 30 incident ALS cases were assessed on both, ECAS and neuropsychological battery. Age and education adjusted cut-off scores were created from a sample of 82 healthy controls. ECAS composite scores (Total, ALS Specific and Non-Specific) were highly correlated with battery composite scores. High correlations were also observed between ECAS and full battery cognitive domains and subtests. The ECAS Total, ALS Specific and Non-Specific scores were highly sensitive to cognitive impairment. ECAS ALS-Specific cognitive domains also evidenced high sensitivity. Individual subtest sensitivity was medium to low, suggesting that caution should be used when interpreting these scores. Low positive predictive values indicated the presence of false positives. Psychometric properties of the ECAS using age and education adjusted norms indicate that the ECAS, when used as an overall measure of cognitive decline, is highly sensitive. Further comprehensive assessment is required for patients that present as impaired on the ECAS.

  19. Automatic detection of DNA double strand breaks after irradiation using an γH2AX assay.

    PubMed

    Hohmann, Tim; Kessler, Jacqueline; Grabiec, Urszula; Bache, Matthias; Vordermark, Dyrk; Dehghani, Faramarz

    2018-05-01

    Radiation therapy belongs to the most common approaches for cancer therapy leading amongst others to DNA damage like double strand breaks (DSB). DSB can be used as a marker for the effect of radiation on cells. For visualization and assessing the extent of DNA damage the γH2AX foci assay is frequently used. The analysis of the γH2AX foci assay remains complicated as the number of γH2AX foci has to be counted. The quantification is mostly done manually, being time consuming and leading to person-dependent variations. Therefore, we present a method to automatically analyze the number of foci inside nuclei, facilitating and quickening the analysis of DSBs with high reliability in fluorescent images. First nuclei were detected in fluorescent images. Afterwards, the nuclei were analyzed independently from each other with a local thresholding algorithm. This approach allowed accounting for different levels of noise and detection of the foci inside the respective nucleus, using Hough transformation searching for circles. The presented algorithm was able to correctly classify most foci in cases of "high" and "average" image quality (sensitivity>0.8) with a low rate of false positive detections (positive predictive value (PPV)>0.98). In cases of "low" image quality the approach had a decreased sensitivity (0.7-0.9), depending on the manual control counter. The PPV remained high (PPV>0.91). Compared to other automatic approaches the presented algorithm had a higher sensitivity and PPV. The used automatic foci detection algorithm was capable of detecting foci with high sensitivity and PPV. Thus it can be used for automatic analysis of images of varying quality.

  20. Integrated multi-ISE arrays with improved sensitivity, accuracy and precision

    NASA Astrophysics Data System (ADS)

    Wang, Chunling; Yuan, Hongyan; Duan, Zhijuan; Xiao, Dan

    2017-03-01

    Increasing use of ion-selective electrodes (ISEs) in the biological and environmental fields has generated demand for high-sensitivity ISEs. However, improving the sensitivities of ISEs remains a challenge because of the limit of the Nernstian slope (59.2/n mV). Here, we present a universal ion detection method using an electronic integrated multi-electrode system (EIMES) that bypasses the Nernstian slope limit of 59.2/n mV, thereby enabling substantial enhancement of the sensitivity of ISEs. The results reveal that the response slope is greatly increased from 57.2 to 1711.3 mV, 57.3 to 564.7 mV and 57.7 to 576.2 mV by electronic integrated 30 Cl- electrodes, 10 F- electrodes and 10 glass pH electrodes, respectively. Thus, a tiny change in the ion concentration can be monitored, and correspondingly, the accuracy and precision are substantially improved. The EIMES is suited for all types of potentiometric sensors and may pave the way for monitoring of various ions with high accuracy and precision because of its high sensitivity.

  1. Sensitive high frequency hearing in earless and partially eared harlequin frogs (Atelopus).

    PubMed

    Womack, Molly C; Christensen-Dalsgaard, Jakob; Coloma, Luis A; Hoke, Kim L

    2018-04-19

    Harlequin frogs, genus Atelopus , communicate at high frequencies despite most species lacking a complete tympanic middle ear that facilitates high frequency hearing in most anurans and other tetrapods. Here we test whether Atelopus are better at sensing high frequency acoustic sound compared to other eared and earless species in the Bufonidae family, determine whether middle ear variation within Atelopus affects hearing sensitivity, and test potential hearing mechanisms in Atelopus We determine that at high frequencies (2000-4000 Hz) Atelopus are 10-34 dB more sensitive than other earless bufonids but are relatively insensitive to mid-range frequencies (900-1500 Hz) compared to eared bufonids. Hearing among Atelopus species is fairly consistent, evidence that the partial middle ears present in a subset of Atelopus species do not convey a substantial hearing advantage. We further demonstrate that Atelopus hearing is not likely facilitated by vibration of the skin overlying the normal tympanic membrane region or the body lung wall, leaving the extratympanic hearing pathways in Atelopus enigmatic. Together these results show Atelopus have sensitive high frequency hearing without the aid of a tympanic middle ear and prompt further study of extratympanic hearing mechanisms in anurans. © 2018. Published by The Company of Biologists Ltd.

  2. Higher sensory processing sensitivity, introversion and ectomorphism: New biomarkers for human creativity in developing rural areas

    PubMed Central

    Rizzo-Sierra, Carlos V; Leon-S, Martha E; Leon-Sarmiento, Fidias E

    2012-01-01

    The highly sensitive trait present in animals, has also been proposed as a human neurobiological trait. People having such trait can process larger amounts of sensory information than usual, making it an excellent attribute that allows to pick up subtle environmental details and cues. Furthermore, this trait correlates to some sort of giftedness such as higher perception, inventiveness, imagination and creativity. We present evidences that support the existance of key neural connectivity between the mentioned trait, higher sensory processing sensitivity, introversion, ectomorphism and creativity. The neurobiological and behavioral implications that these biomarkers have in people living in developing rural areas are discussed as well. PMID:22865969

  3. Organic solvent and temperature-enhanced ion chromatography-high resolution mass spectrometry for the determination of low molecular weight organic and inorganic anions.

    PubMed

    Gilchrist, Elizabeth S; Nesterenko, Pavel N; Smith, Norman W; Barron, Leon P

    2015-03-20

    There has recently been increased interest in coupling ion chromatography (IC) to high resolution mass spectrometry (HRMS) to enable highly sensitive and selective analysis. Herein, the first comprehensive study focusing on the direct coupling of suppressed IC to HRMS without the need for post-suppressor organic solvent modification is presented. Chromatographic selectivity and added HRMS sensitivity offered by organic solvent-modified IC eluents on a modern hyper-crosslinked polymeric anion-exchange resin (IonPac AS18) are shown using isocratic eluents containing 5-50 mM hydroxide with 0-80% methanol or acetonitrile for a range of low molecular weight anions (<165 Da). Comprehensive experiments on IC thermodynamics over a temperature range between 20-45 °C with the eluent containing up to 60% of acetonitrile or methanol revealed markedly different retention behaviour and selectivity for the selected analytes on the same polymer based ion-exchange resin. Optimised sensitivity with HRMS was achieved with as low as 30-40% organic eluent content. Analytical performance characteristics are presented and compared with other IC-MS based works. This study also presents the first application of IC-HRMS to forensic detection of trace low-order anionic explosive residues in latent human fingermarks. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Demographic features and antibiotic resistance among children hospitalized for urinary tract infection in northwest Iran.

    PubMed

    Ghorashi, Ziaaedin; Ghorashi, Sona; Soltani-Ahari, Hassan; Nezami, Nariman

    2011-01-01

    Urinary tract infection (UTI) is the most common serious bacterial infection during infancy. The aim of the present study was to evaluate demographic characteristics, clinical presentations and findings, and antimicrobial resistance among infants and children hospitalized in Tabriz Children's Hospital, Tabriz, Iran. In this descriptive observational study, 100 children who had been admitted with UTI diagnosis to Tabriz Children's Hospital from March 2003 to March 2008 were studied. Demographic characteristics, chief complaints, clinical presentations and findings, urine analysis and cultures, antimicrobial resistance, and sonographic and voiding cystourethrographic reports were evaluated. The mean age of patients was 35.77 ± 39.86 months. The male to female ratio was 0.26. The mean white blood cell count was 12,900 ± 5226/mm(3). Sixty-two percent of patients had leukocytosis. The most common isolated pathogen was Escherichia coli spp (77%) followed by Klebsiella spp (10%), Enterobacter spp (9%), and Enterococcus spp (4%). Isolated pathogens were highly resistant to ampicillin, cotrimoxazole, and cephalexin (71%-96%), intermediate sensitivity to third-generation cephalosporins, and highly sensitive to ciprofloxacin (84.4%), amikacin (83.8%), and nitrofurantoin (82.8%). The most common pathogen of UTI in the hospitalized children was E. coli spp. The isolated pathogens were extremely resistant to ampicillin, and highly sensitive to ciprofloxacin and amikacin.

  5. Trans-generational desensitization and within-generational resensitization of a sucrose-best neuron in the polyphagous herbivore Helicoverpa armigera (Lepidoptera: Noctuidae)

    PubMed Central

    Ma, Ying; Li, Jingjing; Tang, Qingbo; Zhang, Xuening; Zhao, Xincheng; Yan, Fengming; van Loon, Joop J. A.

    2016-01-01

    Dietary exposure of insects to a feeding deterrent substance for hours to days can induce habituation and concomitant desensitization of the response of peripheral gustatory neurons to such a substance. In the present study, larvae of the herbivore Helicoverpa armigera were fed on diets containing either a high, medium or low concentration of sucrose, a major feeding stimulant. The responsiveness of the sucrose-best neuron in the lateral sensilla styloconica on the galea was quantified. Results showed the response of the sucrose-best neuron exposed to high-sucrose diets decreased gradually over successive generations, resulting in complete desensitization in the 5th and subsequent generations. However, the sensitivity was completely restored in the ninth generation after neonate larvae were exposed to low-sucrose diet. These findings demonstrate phenotypic plasticity and exclude inadvertent artificial selection for low sensitivity to sucrose. No significant changes were found in the sensitivity of caterpillars which experienced low- or medium-sucrose diets over the same generations. Such desensitization versus re-sensitization did not generalise to the phagosimulant myo-inositol-sensitive neuron or the feeding deterrent-sensitive neuron. Our results demonstrate that under conditions of high sucrose availability trans-generational desensitization of a neuron sensitive to this feeding stimulant becomes more pronounced whereas re-sensitization occurs within one generation. PMID:27966640

  6. Predicting the potential sensitivity of high elevation wilderness vegetation to changes in atmospheric chemistry - a strategy

    Treesearch

    Anna W. Schoettle

    1995-01-01

    A new strategy to estimate the sensitivity of alpine plant species to atmospheric deposition is presented. This approach utilizes plant physiological and morphological characteristics to estimate pollutant uptake. The plant characteristics can be determined quickly and easily in the field within the constraints of allowable activities in Class I wilderness areas....

  7. Sensor fusion to enable next generation low cost Night Vision systems

    NASA Astrophysics Data System (ADS)

    Schweiger, R.; Franz, S.; Löhlein, O.; Ritter, W.; Källhammer, J.-E.; Franks, J.; Krekels, T.

    2010-04-01

    The next generation of automotive Night Vision Enhancement systems offers automatic pedestrian recognition with a performance beyond current Night Vision systems at a lower cost. This will allow high market penetration, covering the luxury as well as compact car segments. Improved performance can be achieved by fusing a Far Infrared (FIR) sensor with a Near Infrared (NIR) sensor. However, fusing with today's FIR systems will be too costly to get a high market penetration. The main cost drivers of the FIR system are its resolution and its sensitivity. Sensor cost is largely determined by sensor die size. Fewer and smaller pixels will reduce die size but also resolution and sensitivity. Sensitivity limits are mainly determined by inclement weather performance. Sensitivity requirements should be matched to the possibilities of low cost FIR optics, especially implications of molding of highly complex optical surfaces. As a FIR sensor specified for fusion can have lower resolution as well as lower sensitivity, fusing FIR and NIR can solve performance and cost problems. To allow compensation of FIR-sensor degradation on the pedestrian detection capabilities, a fusion approach called MultiSensorBoosting is presented that produces a classifier holding highly discriminative sub-pixel features from both sensors at once. The algorithm is applied on data with different resolution and on data obtained from cameras with varying optics to incorporate various sensor sensitivities. As it is not feasible to record representative data with all different sensor configurations, transformation routines on existing high resolution data recorded with high sensitivity cameras are investigated in order to determine the effects of lower resolution and lower sensitivity to the overall detection performance. This paper also gives an overview of the first results showing that a reduction of FIR sensor resolution can be compensated using fusion techniques and a reduction of sensitivity can be compensated.

  8. High-Sensitivity Fiber-Optic Ultrasound Sensors for Medical Imaging Applications

    PubMed Central

    Wen, H.; Wiesler, D.G.; Tveten, A.; Danver, B.; Dandridge, A.

    2010-01-01

    This paper presents several designs of high-sensitivity, compact fiber-optic ultrasound sensors that may be used for medical imaging applications. These sensors translate ultrasonic pulses into strains in single-mode optical fibers, which are measured with fiber-based laser interferometers at high precision. The sensors are simpler and less expensive to make than piezoelectric sensors, and are not susceptible to electromagnetic interference. It is possible to make focal sensors with these designs, and several schemes are discussed. Because of the minimum bending radius of optical fibers, the designs are suitable for single element sensors rather than for arrays. PMID:9691368

  9. Influence of the composite material thermal expansion on embedded highly birefringent polymer microstructured optical fibers

    NASA Astrophysics Data System (ADS)

    SzelÄ g, M.; Lesiak, P.; Kuczkowski, M.; Domański, A. W.; Woliński, T. R.

    2013-05-01

    Results of our research on embedded highly birefringent polymer microstructured fibers are presented. A composite material sample with fibers embedded between two layers of a multi-layer composite structure is fabricated and characterized. Temperature sensitivities of the polymer fibers are measured in a free space and compared with the fibers embedded in the composite material. It appeared that highly birefringent polymer microstructured fibers exhibit a strong increase in temperature sensitivity when embedded in the composite material, which is due to the stress-induced changes in birefringence created by thermally-induced strain.

  10. Bent optical fiber tapers for refractometery and biosensing

    NASA Astrophysics Data System (ADS)

    Penchev, Emil; Eftimov, Tinko; Bock, Wojtek

    2015-01-01

    We report the results of our study of the spectral shifts caused by surrounding refractive index changes (SRI) in bent fibre tapers. Fused and etched fibre tapers were fabricated using a gas burner and HF acid. Spectral shifts as high as 200 nm have been observed for SRI variations from 1.33 to 1.44 and sensitivity as high as 830 nm/r.i.u. around water RI values. We present results for refractometric measurements of cow milk of varying fat content and compare results with those obtained with conventional Abbe refractometers and high sensitivity double resonance LPGs.

  11. Development of an enzyme free glucose sensor based on copper oxide-graphene composite by using green reducing agent ascorbic acid

    NASA Astrophysics Data System (ADS)

    Palve, Yogesh Pandit; Jha, Neetu

    2018-05-01

    In this research work we have developed high sensitive and selective glucose sensor based on copper oxide-graphene composite which is prepared by green synthesis method and used for nonenzymatic glucose sensor. In present paper we report that present method highly selective, simple, efficient, accurate, ecofriendly, less toxic. The prepared composite were characterized by material characterization like SEM, XRD and also by electrochemical characterization like CV, chronoamperometry represents that copper oxide-graphene shows excellent electrocatalytic activity towards glucose, exhibiting a good sensitivity of 103.84 µA mM-1 cm-2, a fast response time 2s, a low detection limit 0.00033µM and linear range from 10 µM-3000 µM. The present sensor can successfully apply for determination of glucose concentration in human blood sample.

  12. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics

    PubMed Central

    Huang, Haiyun; Wang, Dejun; Xu, Yue

    2015-01-01

    This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW. PMID:26516864

  13. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics.

    PubMed

    Huang, Haiyun; Wang, Dejun; Xu, Yue

    2015-10-27

    This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  14. Numerical Simulation and Mechanical Design for TPS Electron Beam Position Monitors

    NASA Astrophysics Data System (ADS)

    Hsueh, H. P.; Kuan, C. K.; Ueng, T. S.; Hsiung, G. Y.; Chen, J. R.

    2007-01-01

    Comprehensive study on the mechanical design and numerical simulation for the high resolution electron beam position monitors are key steps to build the newly proposed 3rd generation synchrotron radiation research facility, Taiwan Photon Source (TPS). With more advanced electromagnetic simulation tool like MAFIA tailored specifically for particle accelerator, the design for the high resolution electron beam position monitors can be tested in such environment before they are experimentally tested. The design goal of our high resolution electron beam position monitors is to get the best resolution through sensitivity and signal optimization. The definitions and differences between resolution and sensitivity of electron beam position monitors will be explained. The design consideration is also explained. Prototype deign has been carried out and the related simulations were also carried out with MAFIA. The results are presented here. Sensitivity as high as 200 in x direction has been achieved in x direction at 500 MHz.

  15. A viscosity sensitive fluorescent dye for real-time monitoring of mitochondria transport in neurons.

    PubMed

    Baek, Yeonju; Park, Sang Jun; Zhou, Xin; Kim, Gyungmi; Kim, Hwan Myung; Yoon, Juyoung

    2016-12-15

    We present here a viscosity sensitive fluorescent dye, namely thiophene dihemicyanine (TDHC), that enables the specific staining of mitochondria. In comparison to the common mitochondria tracker (Mitotracker Deep Red, MTDR), this dye demonstrated its unique ability for robust staining of mitochondria with high photostability and ultrahigh signal-to-noise ratio (SNR). Moreover, TDHC also showed high sensitivity towards mitochondria membrane potential (ΔΨm) and intramitochondria viscosity change. Consequently, this dye was utilized in real-time monitoring of mitochondria transport in primary cortical neurons. Finally, the Two-Photon Microscopy (TPM) imaging ability of TDHC was also demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Arrays of membrane isolated yttrium-barium-copper-oxide kinetic inductance bolometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindeman, M. A., E-mail: mark.a.lindeman@jpl.nasa.gov; Bonetti, J. A.; Bumble, B.

    We are developing of arrays of membrane isolated resonator-bolometers, each with a kinetic inductance device (KID) to measure the temperature of the membrane. The KIDs are fabricated out of the high temperature superconductor YBCO to allow operation at relatively high temperatures. The bolometers are designed to offer higher sensitivity than sensors operating at 300 K, but they require less expensive and lighter weight cooling than even more sensitive conventional superconducting detectors operating at lower temperatures. The bolometer arrays are applicable as focal planes in infrared imaging spectrometers, such as for planetary science missions or earth observing satellites. We describe the devicesmore » and present measurements of their sensitivity.« less

  17. The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy

    PubMed Central

    Devillé, Walter LJM; Yzermans, Joris C; van Duijn, Nico P; Bezemer, P Dick; van der Windt, Daniëlle AWM; Bouter, Lex M

    2004-01-01

    Background Many studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for the heterogeneity of the dipstick accuracy stimulates an ongoing debate. The objective of the present meta-analysis was to summarise the available evidence on the diagnostic accuracy of the urine dipstick test, taking into account various pre-defined potential sources of heterogeneity. Methods Literature from 1990 through 1999 was searched in Medline and Embase, and by reference tracking. Selected publications should be concerned with the diagnosis of bacteriuria or urinary tract infections, investigate the use of dipstick tests for nitrites and/or leukocyte esterase, and present empirical data. A checklist was used to assess methodological quality. Results 70 publications were included. Accuracy of nitrites was high in pregnant women (Diagnostic Odds Ratio = 165) and elderly people (DOR = 108). Positive predictive values were ≥80% in elderly and in family medicine. Accuracy of leukocyte-esterase was high in studies in urology patients (DOR = 276). Sensitivities were highest in family medicine (86%). Negative predictive values were high in both tests in all patient groups and settings, except for in family medicine. The combination of both test results showed an important increase in sensitivity. Accuracy was high in studies in urology patients (DOR = 52), in children (DOR = 46), and if clinical information was present (DOR = 28). Sensitivity was highest in studies carried out in family medicine (90%). Predictive values of combinations of positive test results were low in all other situations. Conclusions Overall, this review demonstrates that the urine dipstick test alone seems to be useful in all populations to exclude the presence of infection if the results of both nitrites and leukocyte-esterase are negative. Sensitivities of the combination of both tests vary between 68 and 88% in different patient groups, but positive test results have to be confirmed. Although the combination of positive test results is very sensitive in family practice, the usefulness of the dipstick test alone to rule in infection remains doubtful, even with high pre-test probabilities. PMID:15175113

  18. Retrospective comparison of the Low Risk Ankle Rules and the Ottawa Ankle Rules in a pediatric population.

    PubMed

    Ellenbogen, Amy L; Rice, Amy L; Vyas, Pranav

    2017-09-01

    A recent multicenter prospective Canadian study presented prospective evidence supporting the Low Risk Ankle Rules (LRAR) as a means of reducing the number of ankle radiographs ordered for children presenting with an ankle injury while maintaining nearly 100% sensitivity. This is in contrast to a previous prospective study which showed that this rule yielded only 87% sensitivity. It is important to further investigate the LRAR and compare them with the already validated Ottawa Ankle Rules (OAR) to potentially curb healthcare costs and decrease unnecessary radiation exposure without compromising diagnostic accuracy. We conducted a retrospective chart review of 980 qualifying patients ages 12months to 18years presenting with ankle injury to a commonly staffed 310 bed children's hospital and auxiliary site pediatric emergency department. There were 28 high-risk fractures identified. The Ottawa Ankle Rules had a sensitivity of 100% (95% CI 87.7-100), specificity of 33.1% (95% CI 30.1-36.2), and would have reduced the number of ankle radiographs ordered by 32.1%. The Low Risk Ankle Rules had a sensitivity of 85.7% (95% CI 85.7-96), specificity of 64.9% (95% CI 61.8-68), and would have reduced the number of ankle radiographs ordered by 63.1%. The latter rule missed 4 high-risk fractures. The Low Risk Ankle Rules may not be sensitive enough for use in Pediatric Emergency Departments, while the Ottawa Ankle Rules again demonstrated 100% sensitivity. Further research on ways to implement the Ottawa Ankle Rules and maximize its ability to decrease wait times, healthcare costs, and improve patient satisfaction are needed. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Optimizing spectral wave estimates with adjoint-based sensitivity maps

    NASA Astrophysics Data System (ADS)

    Orzech, Mark; Veeramony, Jay; Flampouris, Stylianos

    2014-04-01

    A discrete numerical adjoint has recently been developed for the stochastic wave model SWAN. In the present study, this adjoint code is used to construct spectral sensitivity maps for two nearshore domains. The maps display the correlations of spectral energy levels throughout the domain with the observed energy levels at a selected location or region of interest (LOI/ROI), providing a full spectrum of values at all locations in the domain. We investigate the effectiveness of sensitivity maps based on significant wave height ( H s ) in determining alternate offshore instrument deployment sites when a chosen nearshore location or region is inaccessible. Wave and bathymetry datasets are employed from one shallower, small-scale domain (Duck, NC) and one deeper, larger-scale domain (San Diego, CA). The effects of seasonal changes in wave climate, errors in bathymetry, and multiple assimilation points on sensitivity map shapes and model performance are investigated. Model accuracy is evaluated by comparing spectral statistics as well as with an RMS skill score, which estimates a mean model-data error across all spectral bins. Results indicate that data assimilation from identified high-sensitivity alternate locations consistently improves model performance at nearshore LOIs, while assimilation from low-sensitivity locations results in lesser or no improvement. Use of sub-sampled or alongshore-averaged bathymetry has a domain-specific effect on model performance when assimilating from a high-sensitivity alternate location. When multiple alternate assimilation locations are used from areas of lower sensitivity, model performance may be worse than with a single, high-sensitivity assimilation point.

  20. An approximately factored incremental strategy for calculating consistent discrete aerodynamic sensitivity derivatives

    NASA Technical Reports Server (NTRS)

    Korivi, V. M.; Taylor, A. C., III; Newman, P. A.; Hou, G. J.-W.; Jones, H. E.

    1992-01-01

    An incremental strategy is presented for iteratively solving very large systems of linear equations, which are associated with aerodynamic sensitivity derivatives for advanced CFD codes. It is shown that the left-hand side matrix operator and the well-known factorization algorithm used to solve the nonlinear flow equations can also be used to efficiently solve the linear sensitivity equations. Two airfoil problems are considered as an example: subsonic low Reynolds number laminar flow and transonic high Reynolds number turbulent flow.

  1. Artificial sensory hairs based on the flow sensitive receptor hairs of crickets

    NASA Astrophysics Data System (ADS)

    Dijkstra, M.; van Baar, J. J.; Wiegerink, R. J.; Lammerink, T. S. J.; de Boer, J. H.; Krijnen, G. J. M.

    2005-07-01

    This paper presents the modelling, design, fabrication and characterization of flow sensors based on the wind-receptor hairs of crickets. Cricket sensory hairs are highly sensitive to drag-forces exerted on the hair shaft. Artificial sensory hairs have been realized in SU-8 on suspended SixNy membranes. The movement of the membranes is detected capacitively. Capacitance versus voltage, frequency dependence and directional sensitivity measurements have been successfully carried out on fabricated sensor arrays, showing the viability of the concept.

  2. BEAMS Lab: Novel approaches to finding a balance between throughput and sensitivity

    NASA Astrophysics Data System (ADS)

    Liberman, Rosa G.; Skipper, Paul L.; Prakash, Chandra; Shaffer, Christopher L.; Flarakos, Jimmy; Tannenbaum, Steven R.

    2007-06-01

    Development of 14C AMS has long pursued the twin goals of maximizing both sensitivity and precision in the interest, among others, of optimizing radiocarbon dating. Application of AMS to biomedical research is less constrained with respect to sensitivity requirements, but more demanding of high throughput. This work presents some technical and conceptual developments in sample processing and analytical instrumentation designed to streamline the process of extracting quantitative data from the various types of samples encountered in analytical biochemistry.

  3. Stimulus Sensitivity of a Spiking Neural Network Model

    NASA Astrophysics Data System (ADS)

    Chevallier, Julien

    2018-02-01

    Some recent papers relate the criticality of complex systems to their maximal capacity of information processing. In the present paper, we consider high dimensional point processes, known as age-dependent Hawkes processes, which have been used to model spiking neural networks. Using mean-field approximation, the response of the network to a stimulus is computed and we provide a notion of stimulus sensitivity. It appears that the maximal sensitivity is achieved in the sub-critical regime, yet almost critical for a range of biologically relevant parameters.

  4. Graphene oxide-enhanced sol-gel transition sensitivity and drug release performance of an amphiphilic copolymer-based nanocomposite

    PubMed Central

    Hu, Huawen; Wang, Xiaowen; Lee, Ka I; Ma, Kaikai; Hu, Hong; Xin, John H.

    2016-01-01

    We report the fabrication of a highly sensitive amphiphilic copolymer-based nanocomposite incorporating with graphene oxide (GO), which exhibited a low-intensity UV light-triggered sol-gel transition. Non-cytotoxicity was observed for the composite gels after the GO incorporation. Of particular interest were the microchannels that were formed spontaneously within the GO-incorporated UV-gel, which expedited sustained drug release. Therefore, the present highly UV-sensitive, non-cytotoxic amphiphilic copolymer-based composites is expected to provide enhanced photothermal therapy and chemotherapy by means of GO’s unique photothermal properties, as well as through efficient passive targeting resulting from the sol-gel transition characteristic of the copolymer-based system with improved sensitivity, which thus promises the enhanced treatment of patients with cancer and other diseases. PMID:27539298

  5. Silver halide sensitized gelatin derived from BB-640 holographic emulsion.

    PubMed

    Neipp, C; Pascual, I; Beléndez, A

    1999-03-10

    Silver halide sensitized gelatin (SHSG) is one of the most interesting techniques for the production of holographic optical elements, achieving relatively high sensitivity of photographic material with a low scattering of dichromated gelatin. Here we present experimental results for SHSG derived from the novel BB-640, a red-sensitive ultra-fine-grain emulsion from Holographic Recording Technologies (Steinau, Germany). The material is characterized before recording and after processing, and information about the thickness, absorption, and refractive-index modulation of the final holograms is obtained. The influence of the developer is analyzed, and diffraction efficiencies as great as 96.2% (after allowing for reflections) with a transmission of 1% and absorption and scatter losses of 2.8% are obtained with AAC developer. Our investigations reveal that high-quality SHSG transmission holograms may be obtained with the new BB-640 plates.

  6. High-sensitive transmission type of gas sensor based on guided-mode resonance in coupled gratings

    NASA Astrophysics Data System (ADS)

    Wang, La; Sang, Tian; Li, Junlang; Zhou, Jianyu; Wang, Benxin; Wang, Yueke

    2018-07-01

    A new type of high-sensitive transmission gas sensor based on the coupled gratings (CGs) and the corresponding Fabry-Pérot-like (FP-like) model for evaluating the resonance peaks are presented. The estimated locations of the FP-like resonance obtained by this theoretical model are well agreed with those of the exact results. It is shown that a narrow FP-like channel with high transmissivity occurs in the opaque background of the CGs, and its location is shifted linearly with the variation of the refractive index (RI) of the gaseous analyte. The transmission peak of the sideband can be selected as a reference, and it remains nearly fixed as the RI of the analyte is varied. Good sensing properties of the CGs sensor can be maintained, regardless of whether the two grating membranes are laterally aligned or not. The sensitivity of the CGs sensor is immune to the variation of the RI of the substrate. By selecting the higher order FP-like mode (m = 4), sensitivity as high as 748 nm/RIU with the figure of merit of 374 can be achieved.

  7. The strain-rate sensitivity of high-strength high-toughness steels.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dilmore, M.F.; Crenshaw, Thomas B.; Boyce, Brad Lee

    2006-01-01

    The present study examines the strain-rate sensitivity of four high strength, high-toughness alloys at strain rates ranging from 0.0002 s-1 to 200 s-1: Aermet 100, a modified 4340, modified HP9-4-20, and a recently developed Eglin AFB steel alloy, ES-1c. A refined dynamic servohydraulic method was used to perform tensile tests over this entire range. Each of these alloys exhibit only modest strain-rate sensitivity. Specifically, the strain-rate sensitivity exponent m, is found to be in the range of 0.004-0.007 depending on the alloy. This corresponds to a {approx}10% increase in the yield strength over the 7-orders of magnitude change in strain-rate.more » Interestingly, while three of the alloys showed a concominant {approx}3-10% drop in their ductility with increasing strain-rate, the ES1-c alloy actually exhibited a 25% increase in ductility with increasing strain-rate. Fractography suggests the possibility that at higher strain-rates ES-1c evolves towards a more ductile dimple fracture mode associated with microvoid coalescence.« less

  8. Determination of Chlorinated Hydrocarbons in Water Using Highly Sensitive Mid-Infrared Sensor Technology

    NASA Astrophysics Data System (ADS)

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-08-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.

  9. Determination of Chlorinated Hydrocarbons in Water Using Highly Sensitive Mid-Infrared Sensor Technology

    PubMed Central

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-01-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring. PMID:23982222

  10. Determination of chlorinated hydrocarbons in water using highly sensitive mid-infrared sensor technology.

    PubMed

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-01-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.

  11. An optical MEMS accelerometer fabricated using double-sided deep reactive ion etching on silicon-on-insulator wafer

    NASA Astrophysics Data System (ADS)

    Teo, Adrian J. T.; Li, Holden; Tan, Say Hwa; Yoon, Yong-Jin

    2017-06-01

    Optical MEMS devices provide fast detection, electromagnetic resilience and high sensitivity. Using this technology, an optical gratings based accelerometer design concept was developed for seismic motion detection purposes that provides miniaturization, high manufacturability, low costs and high sensitivity. Detailed in-house fabrication procedures of a double-sided deep reactive ion etching (DRIE) on a silicon-on-insulator (SOI) wafer for a micro opto electro mechanical system (MOEMS) device are presented and discussed. Experimental results obtained show that the conceptual device successfully captured motion similar to a commercial accelerometer with an average sensitivity of 13.6 mV G-1, and a highest recorded sensitivity of 44.1 mV G-1. A noise level of 13.5 mV was detected due to experimental setup limitations. This is the first MOEMS accelerometer developed using double-sided DRIE on SOI wafer for the application of seismic motion detection, and is a breakthrough technology platform to open up options for lower cost MOEMS devices.

  12. High-sensitivity strain visualization using electroluminescence technologies

    NASA Astrophysics Data System (ADS)

    Xu, Jian; Jo, Hongki

    2016-04-01

    Visualizing mechanical strain/stress changes is an emerging area in structural health monitoring. Several ways are available for strain change visualization through the color/brightness change of the materials subjected to the mechanical stresses, for example, using mechanoluminescence (ML) materials and mechanoresponsive polymers (MRP). However, these approaches were not effectively applicable for civil engineering system yet, due to insufficient sensitivity to low-level strain of typical civil structures and limitation in measuring both static and dynamic strain. In this study, design and validation for high-sensitivity strain visualization using electroluminescence technologies are presented. A high-sensitivity Wheatstone bridge, of which bridge balance is precisely controllable circuits, is used with a gain-adjustable amplifier. The monochrome electroluminescence (EL) technology is employed to convert both static and dynamic strain change into brightness/color change of the EL materials, through either brightness change mode (BCM) or color alternation mode (CAM). A prototype has been made and calibrated in lab, the linearity between strain and brightness change has been investigated.

  13. Nested PCR Assay for Eight Pathogens: A Rapid Tool for Diagnosis of Bacterial Meningitis.

    PubMed

    Bhagchandani, Sharda P; Kubade, Sushant; Nikhare, Priyanka P; Manke, Sonali; Chandak, Nitin H; Kabra, Dinesh; Baheti, Neeraj N; Agrawal, Vijay S; Sarda, Pankaj; Mahajan, Parikshit; Ganjre, Ashish; Purohit, Hemant J; Singh, Lokendra; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S

    2016-02-01

    Bacterial meningitis is a dreadful infectious disease with a high mortality and morbidity if remained undiagnosed. Traditional diagnostic methods for bacterial meningitis pose a challenge in accurate identification of pathogen, making prognosis difficult. The present study is therefore aimed to design and evaluate a specific and sensitive nested 16S rDNA genus-based polymerase chain reaction (PCR) assay using clinical cerebrospinal fluid (CSF) for rapid diagnosis of eight pathogens causing the disease. The present work was dedicated to development of an in-house genus specific 16S rDNA nested PCR covering pathogens of eight genera responsible for causing bacterial meningitis using newly designed as well as literature based primers for respective genus. A total 150 suspected meningitis CSF obtained from the patients admitted to Central India Institute of Medical Sciences (CIIMS), India during the period from August 2011 to May 2014, were used to evaluate clinical sensitivity and clinical specificity of optimized PCR assays. The analytical sensitivity and specificity of our newly designed genus-specific 16S rDNA PCR were found to be ≥92%. With such a high sensitivity and specificity, our in-house nested PCR was able to give 100% sensitivity in clinically confirmed positive cases and 100% specificity in clinically confirmed negative cases indicating its applicability in clinical diagnosis. Our in-house nested PCR system therefore can diagnose the accurate pathogen causing bacterial meningitis and therefore be useful in selecting a specific treatment line to minimize morbidity. Results are obtained within 24 h and high sensitivity makes this nested PCR assay a rapid and accurate diagnostic tool compared to traditional culture-based methods.

  14. Modulation of meso-limbic reward processing by motivational tendencies in young adolescents and adults

    PubMed Central

    Joseph, Jane E.; Zhu, Xun; Lynam, Donald; Kelly, Thomas H.

    2015-01-01

    Adolescence is a particularly vulnerable period for the onset of substance use disorders and other psychopathology. Individual variability in motivational tendencies and temperament and significant changes in functional brain organization during adolescence are important factors to consider in the development of substance use and dependence. Recent conceptualizations suggest that sensitivity to reward is heightened in adolescence and that this motivation tendency may precipitate subsequent substance abuse. The present study examined the role of personality traits in mesolimbic neurobehavioral response on a monetary incentive delay (MID) task in young adolescents (11–14 years) and emerging adults (18–25 years) using functional magnetic resonance imaging. As a group, adolescents were not more sensitive to gains than losses compared to adults during either anticipatory and feedback phases; instead, compared to adults they showed less sensitivity to incentive magnitude in mesolimbic circuitry during anticipation and feedback stages. However, personality modulated this response such that adolescents high in impulsivity or low in avoidance tendencies showed greater gain sensitivity and adolescents high in avoidance showed greater loss sensitivity during cue anticipation. In adults, mesolimbic response was modulated by the impulsivity construct such that high-impulsive adults showed reduced magnitude sensitivity during both anticipation and feedback compared to low impulsive adults. The present findings suggest that impulsive personality significantly modulates mesolimbic reward response during both adolescence and adulthood but avoidance and approach tendencies also modulate this response in adolescents. Moreover, personality modulated incentive valence in adolescents but incentive magnitude in adults. Collectively, these findings suggest that mesolimbic reward circuitry function is modulated by somewhat different parameters in adolescence than in adulthood. PMID:26690806

  15. The HEART score with high-sensitive troponin T at presentation: ruling out patients with chest pain in the emergency room.

    PubMed

    Santi, Luca; Farina, Gabriele; Gramenzi, Annagiulia; Trevisani, Franco; Baccini, Margherita; Bernardi, Mauro; Cavazza, Mario

    2017-04-01

    The HEART score is a simple scoring system, ranging from 0 to 10, specifically developed for risk stratification of patients with undifferentiated chest pain. It has been validated for the conventional troponin, but not for high-sensitive troponin. We assess a modified version of the HEART score using a single high-sensitivity troponin T dosage at presentation, regardless of symptom duration, and with different ECG criteria to evaluate if the patients with a low HEART score could be safely discharged early. The secondary aim was to confirm a statistically significant difference in each HEART score group (low 0-3, intermediate 4-6, high 7-10) in the occurrence of major adverse cardiac events at 30 and 180 days. We retrospectively analyzed the HEART score of 1597 consecutive patients admitted to the Emergency Department of our Hospital for chest pain between January 1 and June 30, 2014. Of these, 190 did not meet the inclusion criteria and 29 were lost to follow-up. None of the 512 (37.2 %) patients with a low HEART score had an event within 180 days. The difference between the cumulative incidences of events in the three HEART score groups was statistically significant (P < 0.0001). We demonstrate that it might be possible to safely discharge Emergency Department chest pain patients with a low modified HEART score after an initial determination of high-sensitive troponin T, without a prolonged observation period or an additional cardiac testing.

  16. Highly sensitive and quantitative evaluation of the EGFR T790M mutation by nanofluidic digital PCR

    PubMed Central

    Iwama, Eiji; Takayama, Koichi; Harada, Taishi; Okamoto, Isamu; Ookubo, Fumihiko; Kishimoto, Junji; Baba, Eishi; Oda, Yoshinao; Nakanishi, Yoichi

    2015-01-01

    The mutation of T790M in EGFR is a major mechanism of resistance to treatment with EGFR-TKIs. Only qualitative detection (presence or absence) of T790M has been described to date, however. Digital PCR (dPCR) analysis has recently been applied to the quantitative detection of target molecules in cancer with high sensitivity. In the present study, 25 tumor samples (13 obtained before and 12 after EGFR-TKI treatment) from 18 NSCLC patients with activating EGFR mutations were evaluated for T790M with dPCR. The ratio of the number of T790M alleles to that of activating mutation alleles (T/A) was determined. dPCR detected T790M in all 25 samples. Although T790M was present in all pre-TKI samples from 13 patients, 10 of these patients had a low T/A ratio and manifested substantial tumor shrinkage during treatment with EGFR-TKIs. In six of seven patients for whom both pre- and post-TKI samples were available, the T/A ratio increased markedly during EGFR-TKI treatment. Highly sensitive dPCR thus detected T790M in all NSCLC patients harboring activating EGFR mutations whether or not they had received EGFR-TKI treatment. Not only highly sensitive but also quantitative detection of T790M is important for evaluation of the contribution of T790M to EGFR-TKI resistance. PMID:26015401

  17. Integration of Biomaterials into Sensors Based on Organic Thin-Film Transistors.

    PubMed

    Wu, Xiaohan; Zhou, Jiachen; Huang, Jia

    2018-05-22

    Sensors based on organic thin-film transistors (OTFTs) present various advantages, including high sensitivity and mechanical flexibility, thus possessing potential applications such as wearable devices and biomedical electronics for health monitoring, etc. However, such applications are partially limited by the biocompatibility, biodegradability, and sensitivity to target analytes of OTFT-based sensors, which can be improved by the incorporation of diverse biomaterials. This article presents a brief review from the viewpoint of the type of the integrated biomaterials, including naturally occurring biomacromolecules such as proteins, enzymes, and deoxyribonucleic acid, as well as biocompatible polymers such as polylactide, poly(lactide-co-glycolide), poly(ethylene glycol), cellulose, polydimethylsiloxane, parylene, etc. It is believed that future work in this field should be devoted to the selectivity, sensitivity, and stability improvement as well as the high-level integration and sophistication on the basis of the OTFT-based sensors for physical, chemical, and biological sensing applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. TL and EPR studies of Cu, Ag and P doped Li2B4O7 phosphor

    NASA Astrophysics Data System (ADS)

    Can, N.; Karali, T.; Townsend, P. D.; Yildiz, F.

    2006-05-01

    Key characteristics of a newly prepared tissue-equivalent, highly sensitive thermoluminescence dosimeter, Li2B4O7:Cu,Ag,P, are presented. The material was developed at the Institute of Nuclear Sciences, Belgrade, in the form of sintered pellets. A new preparation procedure has greatly increased the sensitivity of the basic copper activated lithium borate and the glow curve of Li2B4O7 : Cu,Ag,P consists of a well-defined main dosimetric peak situated at about 460-465 K with a sensitivity which is about four to five times higher than that of LiF : Mg,Ti (TLD-100). The exceptionally good response features of Li2B4O7 : Cu,Ag,P are attributed to the incorporation of Cu as a dopant. Both low and high temperature emission spectra are presented and the origins of the various emission bands are considered. Additional data are provided from electron paramagnetic resonance measurements.

  19. A Small Mission Featuring an Imaging X-ray Polarimeter with High Sensitivity

    NASA Technical Reports Server (NTRS)

    Weisskopf, Martin C.; Baldini, Luca; Bellazini, Ronaldo; Brez, Alessandro; Costa, Enrico; Dissley, Richard; Elsner, Ronald; Fabiani, Sergio; Matt, Giorgio; Minuti, Massimo; hide

    2013-01-01

    We present a detailed description of a small mission capable of obtaining high precision and meaningful measurement of the X-ray polarization of a variety of different classes of cosmic X-ray sources. Compared to other ideas that have been suggested this experiment has demonstrated in the laboratory a number of extremely important features relevant to the ultimate selection of such a mission by a funding agency. The most important of these questions are: 1) Have you demonstrated the sensitivity to a polarized beam at the energies of interest (i.e. the energies which represent the majority (not the minority) of detected photons from the X-ray source of interest? 2) Have you demonstrated that the device's sensitivity to an unpolarized beam is really negligible and/or quantified the impact of any systematic effects upon actual measurements? We present our answers to these questions backed up by laboratory measurements and give an overview of the mission.

  20. Detection beyond the Debye screening length in a high-frequency nanoelectronic biosensor.

    PubMed

    Kulkarni, Girish S; Zhong, Zhaohui

    2012-02-08

    Nanosensors based on the unique electronic properties of nanotubes and nanowires offer high sensitivity and have the potential to revolutionize the field of Point-of-Care (POC) medical diagnosis. The direct current (dc) detection of a wide array of organic and inorganic molecules has been demonstrated on these devices. However, sensing mechanism based on measuring changes in dc conductance fails at high background salt concentrations, where the sensitivity of the devices suffers from the ionic screening due to mobile ions present in the solution. Here, we successfully demonstrate that the fundamental ionic screening effect can be mitigated by operating single-walled carbon nanotube field effect transistor as a high-frequency biosensor. The nonlinear mixing between the alternating current excitation field and the molecular dipole field can generate mixing current sensitive to the surface-bound biomolecules. Electrical detection of monolayer streptavidin binding to biotin in 100 mM buffer solution is achieved at a frequency beyond 1 MHz. Theoretical modeling confirms improved sensitivity at high frequency through mitigation of the ionic screening effect. The results should promise a new biosensing platform for POC detection, where biosensors functioning directly in physiologically relevant condition are desired. © 2012 American Chemical Society

  1. FEAST: sensitive local alignment with multiple rates of evolution.

    PubMed

    Hudek, Alexander K; Brown, Daniel G

    2011-01-01

    We present a pairwise local aligner, FEAST, which uses two new techniques: a sensitive extension algorithm for identifying homologous subsequences, and a descriptive probabilistic alignment model. We also present a new procedure for training alignment parameters and apply it to the human and mouse genomes, producing a better parameter set for these sequences. Our extension algorithm identifies homologous subsequences by considering all evolutionary histories. It has higher maximum sensitivity than Viterbi extensions, and better balances specificity. We model alignments with several submodels, each with unique statistical properties, describing strongly similar and weakly similar regions of homologous DNA. Training parameters using two submodels produces superior alignments, even when we align with only the parameters from the weaker submodel. Our extension algorithm combined with our new parameter set achieves sensitivity 0.59 on synthetic tests. In contrast, LASTZ with default settings achieves sensitivity 0.35 with the same false positive rate. Using the weak submodel as parameters for LASTZ increases its sensitivity to 0.59 with high error. FEAST is available at http://monod.uwaterloo.ca/feast/.

  2. Novel multichannel surface plasmon resonance photonic crystal fiber biosensor

    NASA Astrophysics Data System (ADS)

    Hameed, Mohamed Farhat O.; Alrayk, Yassmin K. A.; Shaalan, A. A.; El Deeb, Walid S.; Obayya, S. S. A.

    2016-04-01

    In this paper, a novel design of highly sensitive biosensor based on photonic crystal fiber is presented and analyzed using full vectorial finite element method. The suggested design depends on using silver layer as a plasmonic active material coated by a gold layer to protect silver oxidation. The reported sensor is based on the detection using the quasi transverse electric (TE) and quasi transverse magnetic (TM) modes which offers the possibility of multi-channel/multi-analyte sensing. The sensor geometrical parameters are optimized to achieve high sensitivity for the two polarized modes. High refractive index sensitivity of about 4750 nm/RIU (refractive index unit) and 4300 nm/RIU with corresponding resolutions of 2.1×10-5 RIU, and 2.33×10-5 RIU can be obtained for the quasi TM and quasi TE modes, respectively.

  3. L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Titus, Charles J.; Baker, Michael L.; Lee, Sang Jun

    Here, we present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements then demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100–2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique abilitymore » to characterize frozen solutions of radiation- and temperature-sensitive samples.« less

  4. The Science and Design of the AGIS Observatory

    NASA Astrophysics Data System (ADS)

    Falcone, Abraham; Aliu, E.; Arlen, T.; Benbow, W.; Buckley, J.; Bugaev, S.; Byrum, K.; Ciupik, L.; Coppi, P.; Digel, S.; Drake, G.; Finley, J.; Fortson, L.; Franco, J.; Funk, S.; Guarino, V.; Gyuk, G.; Hanna, D.; Hiriart, D.; Humensky, B.; Holder, J.; Kaaret, P.; Karlsson, N.; Kieda, D.; Konopelko, A.; Krawczynski, H.; Krennrich, F.; LeBohec, S.; Maier, G.; Mukherjee, R.; Ong, R.; Otte, N.; Pareschi, G.; Pohl, M.; Quinn, J.; Ramsey, B.; Romani, R.; Rovero, A. C.; Schroedter, M.; Sinnis, C.; Slane, P.; Smith, A.; Swordy, S.; Tajima, H.; Vassiliev, V.; Wagner, R.; Wakely, S. P.; Weekes, T. C.; Weinstein, A.; Williams, D.

    2010-01-01

    The AGIS observatory is a next-generation array of imaging atmospheric Cherenkov telescopes (IACTs) for gamma-ray astronomy between 100GeV and 100 TeV. The AGIS observatory is the next logical step in high energy gamma-ray astronomy, offering improved angular resolution and sensitivity compared to FERMI, and overlapping the high energy end of FERMI's sensitivity band. The baseline AGIS observatory will employ an array of 36 Schwarzschild-Couder IACTs in combination with a highly pixelated (0.05 degree/pixel) camera. The instrument is designed to provide millicrab sensitivity over a wide (8 degree diameter) field of view, allowing both deep studies of faint point sources as well as efficient mapping of the Galactic plane and extended sources. This presentation will include a description of science drivers behind the AGIS observatory and the design and status of the project.

  5. L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array

    DOE PAGES

    Titus, Charles J.; Baker, Michael L.; Lee, Sang Jun; ...

    2017-12-07

    Here, we present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements then demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100–2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique abilitymore » to characterize frozen solutions of radiation- and temperature-sensitive samples.« less

  6. High prevalence of heartburn and low acid sensitivity in patients with idiopathic achalasia.

    PubMed

    Ponce, Julio; Ortiz, Vicente; Maroto, Nuria; Ponce, Marta; Bustamante, Marco; Garrigues, Vicente

    2011-03-01

    Heartburn is frequently reported by patients with achalasia before treatment. However, the esophageal sensitivity to acid as a possible mediator of this symptom has not been previously evaluated. To evaluate the prevalence of gastroesophageal reflux symptoms and the esophageal sensitivity to acid perfusion in patients with untreated achalasia. Forty patients with achalasia were prospectively evaluated. Forty-three patients with gastroesophageal reflux disease comprised the control group (ten of them with Barrett's esophagus). Symptoms were evaluated by a structured clinical questionnaire. Objective assessment was performed by ambulatory 24-h esophageal pH monitoring and endoscopy. Esophageal sensitivity to acid was evaluated by esophageal perfusion of ClH 0.1 N. Fifteen (37%) of the 40 patients with achalasia presented heartburn, but only four of them had esophagitis and/or abnormal esophageal pH recording. Eight patients had abnormal pH recording. Three patients had esophagitis. The esophagus was sensitive to acid in seven (17%) patients with achalasia, three of them with heartburn and one with abnormal pH recording. In the control group, 40 of 43 (93%) presented heartburn. Acid perfusion was positive in 32 (74%). Sensitivity to acid was lower in patients with achalasia than in those with gastroesophageal reflux disease with or without Barrett's esophagus. The prevalence of heartburn in patients with achalasia is high, although its association with objective indicators of gastroesophageal reflux disease is weak. Patients with achalasia have lower esophageal sensitivity to acid than patients with GERD, suggesting that heartburn is does not arise from this condition.

  7. Sensitivity to the Positional Information of Morphemes inside Chinese Compound Words and Its Relationship with Word Reading

    ERIC Educational Resources Information Center

    Liu, Duo; Chung, Kevin Kien Hoa; Zhang, Yimin; Lu, Zheng

    2014-01-01

    The purpose of the present study was to investigate developmental differences in lexical processing and sensitivity to the positional information of constituent morphemes with reference to Chinese word-reading ability. One hundred mainland Chinese children (50 second graders and 50 third graders) and 22 high school students were tested with a…

  8. The role of noise sensitivity in the noise-response relation: A comparison of three international airport studies

    NASA Astrophysics Data System (ADS)

    van Kamp, Irene; Job, R. F. Soames; Hatfield, Julie; Haines, Mary; Stellato, Rebecca K.; Stansfeld, Stephen A.

    2004-12-01

    In order to examine the role of noise sensitivity in response to environmental noise, this paper presents detailed comparisons of socio-acoustic studies conducted around international airports in Amsterdam, Sydney, and London. Earlier findings that noise sensitivity moderates the effect of noise on annoyance were examined to see if they could be replicated in each of the datasets, independent of the technique of measuring noise sensitivity. The relation between exposure to aircraft noise and noise annoyance was studied separately for groups of individuals with low, medium, and high noise sensitivity, with statistical adjustment for relevant confounders. Results support the previous findings that noise sensitivity is an independent predictor of annoyance and adds to the prediction of noise annoyance afforded by noise exposure level by up to 26% of explained variance. There is no evidence of a moderating effect, whereby the covariation between noise exposure level and annoyance is weak for people who score at the extreme high or low end of the sensitivity scale, and strong for people who score in the middle of the sensitivity scale. Generally, noise sensitivity appears to increase annoyance independently of the level of noise exposure after adjustment for relevant confounders. These findings were consistent across the three datasets. .

  9. The Design and Operation of Ultra-Sensitive and Tunable Radio-Frequency Interferometers.

    PubMed

    Cui, Yan; Wang, Pingshan

    2014-12-01

    Dielectric spectroscopy (DS) is an important technique for scientific and technological investigations in various areas. DS sensitivity and operating frequency ranges are critical for many applications, including lab-on-chip development where sample volumes are small with a wide range of dynamic processes to probe. In this work, we present the design and operation considerations of radio-frequency (RF) interferometers that are based on power-dividers (PDs) and quadrature-hybrids (QHs). Such interferometers are proposed to address the sensitivity and frequency tuning challenges of current DS techniques. Verified algorithms together with mathematical models are presented to quantify material properties from scattering parameters for three common transmission line sensing structures, i.e., coplanar waveguides (CPWs), conductor-backed CPWs, and microstrip lines. A high-sensitivity and stable QH-based interferometer is demonstrated by measuring glucose-water solution at a concentration level that is ten times lower than some recent RF sensors while our sample volume is ~1 nL. Composition analysis of ternary mixture solutions are also demonstrated with a PD-based interferometer. Further work is needed to address issues like system automation, model improvement at high frequencies, and interferometer scaling.

  10. Dual-sensitivity profilometry with defocused projection of binary fringes.

    PubMed

    Garnica, G; Padilla, M; Servin, M

    2017-10-01

    A dual-sensitivity profilometry technique based on defocused projection of binary fringes is presented. Here, two sets of fringe patterns with a sinusoidal profile are produced by applying the same analog low-pass filter (projector defocusing) to binary fringes with a high- and low-frequency spatial carrier. The high-frequency fringes have a binary square-wave profile, while the low-frequency binary fringes are produced with error-diffusion dithering. The binary nature of the binary fringes removes the need for calibration of the projector's nonlinear gamma. Working with high-frequency carrier fringes, we obtain a high-quality wrapped phase. On the other hand, working with low-frequency carrier fringes we found a lower-quality, nonwrapped phase map. The nonwrapped estimation is used as stepping stone for dual-sensitivity temporal phase unwrapping, extending the applicability of the technique to discontinuous (piecewise continuous) surfaces. We are proposing a single defocusing level for faster high- and low-frequency fringe data acquisition. The proposed technique is validated with experimental results.

  11. Fiber-optic refractometer based on an etched high-Q π-phase-shifted fiber-Bragg-grating.

    PubMed

    Zhang, Qi; Ianno, Natale J; Han, Ming

    2013-07-10

    We present a compact and highly-sensitive fiber-optic refractometer based on a high-Q π-phase-shifted fiber-Bragg-grating (πFBG) that is chemically etched to the core of the fiber. Due to the p phase-shift, a strong πFBG forms a high-Q optical resonator and the reflection spectrum features an extremely narrow notch that can be used for highly sensitivity refractive index measurement. The etched πFBG demonstrated here has a diameter of ~9.3 μm and a length of only 7 mm, leading to a refractive index responsivity of 2.9 nm/RIU (RIU: refractive index unit) at an ambient refractive index of 1.318. The reflection spectrum of the etched πFBG features an extremely narrow notch with a linewidth of only 2.1 pm in water centered at ~1,550 nm, corresponding to a Q-factor of 7.4 × 10(5), which allows for potentially significantly improved sensitivity over refractometers based on regular fiber Bragg gratings.

  12. Present-day nearshore pH differentially depresses fertilization in congeneric sea urchins.

    PubMed

    Frieder, Christina A

    2014-02-01

    Ocean acidification impacts fertilization in some species of sea urchin, but whether sensitivity is great enough to be influenced by present-day pH variability has not been documented. In this study, fertilization in two congeneric sea urchins, Strongylocentrotus purpuratus and S. franciscanus, was found to be sensitive to reduced pH, <7.50, but only within a range of sperm-egg ratios that was species-specific. By further testing fertilization across a broad range of pH, pH-fertilization curves were generated and revealed that S. purpuratus was largely robust to pH, while fertilization in S. franciscanus was sensitive to even modest reductions in pH. Combining the pH-fertilization response curves with pH data collected from these species' habitat demonstrated that relative fertilization success remained high for S. purpuratus but could be as low as 79% for S. franciscanus during periods of naturally low pH. In order for S. franciscanus to maintain high fertilization success in the present and future, adequate adult densities, and thus sufficient sperm-egg ratios, will be required to negate the effects of low pH. In contrast, fertilization of S. purpuratus was robust to a broad range of pH, encompassing both present-day and future ocean acidification scenarios, even though the two congeners have similar habitats.

  13. A Wireless Fiber Photometry System Based on a High-Precision CMOS Biosensor With Embedded Continuous-Time Modulation.

    PubMed

    Khiarak, Mehdi Noormohammadi; Martianova, Ekaterina; Bories, Cyril; Martel, Sylvain; Proulx, Christophe D; De Koninck, Yves; Gosselin, Benoit

    2018-06-01

    Fluorescence biophotometry measurements require wide dynamic range (DR) and high-sensitivity laboratory apparatus. Indeed, it is often very challenging to accurately resolve the small fluorescence variations in presence of noise and high-background tissue autofluorescence. There is a great need for smaller detectors combining high linearity, high sensitivity, and high-energy efficiency. This paper presents a new biophotometry sensor merging two individual building blocks, namely a low-noise sensing front-end and a order continuous-time modulator (CTSDM), into a single module for enabling high-sensitivity and high energy-efficiency photo-sensing. In particular, a differential CMOS photodetector associated with a differential capacitive transimpedance amplifier-based sensing front-end is merged with an incremental order 1-bit CTSDM to achieve a large DR, low hardware complexity, and high-energy efficiency. The sensor leverages a hardware sharing strategy to simplify the implementation and reduce power consumption. The proposed CMOS biosensor is integrated within a miniature wireless head mountable prototype for enabling biophotometry with a single implantable fiber in the brain of live mice. The proposed biophotometry sensor is implemented in a 0.18- CMOS technology, consuming from a 1.8- supply voltage, while achieving a peak dynamic range of over a 50- input bandwidth, a sensitivity of 24 mV/nW, and a minimum detectable current of 2.46- at a 20- sampling rate.

  14. Non-Faradaic Electrochemical Detection of Exocytosis from Mast and Chromaffin Cells Using Floating-Gate MOS Transistors.

    PubMed

    Jayant, Krishna; Singhai, Amit; Cao, Yingqiu; Phelps, Joshua B; Lindau, Manfred; Holowka, David A; Baird, Barbara A; Kan, Edwin C

    2015-12-21

    We present non-faradaic electrochemical recordings of exocytosis from populations of mast and chromaffin cells using chemoreceptive neuron MOS (CνMOS) transistors. In comparison to previous cell-FET-biosensors, the CνMOS features control (CG), sensing (SG) and floating gates (FG), allows the quiescent point to be independently controlled, is CMOS compatible and physically isolates the transistor channel from the electrolyte for stable long-term recordings. We measured exocytosis from RBL-2H3 mast cells sensitized by IgE (bound to high-affinity surface receptors FcεRI) and stimulated using the antigen DNP-BSA. Quasi-static I-V measurements reflected a slow shift in surface potential () which was dependent on extracellular calcium ([Ca]o) and buffer strength, which suggests sensitivity to protons released during exocytosis. Fluorescent imaging of dextran-labeled vesicle release showed evidence of a similar time course, while un-sensitized cells showed no response to stimulation. Transient recordings revealed fluctuations with a rapid rise and slow decay. Chromaffin cells stimulated with high KCl showed both slow shifts and extracellular action potentials exhibiting biphasic and inverted capacitive waveforms, indicative of varying ion-channel distributions across the cell-transistor junction. Our approach presents a facile method to simultaneously monitor exocytosis and ion channel activity with high temporal sensitivity without the need for redox chemistry.

  15. Non-Faradaic Electrochemical Detection of Exocytosis from Mast and Chromaffin Cells Using Floating-Gate MOS Transistors

    PubMed Central

    Jayant, Krishna; Singhai, Amit; Cao, Yingqiu; Phelps, Joshua B.; Lindau, Manfred; Holowka, David A.; Baird, Barbara A.; Kan, Edwin C.

    2015-01-01

    We present non-faradaic electrochemical recordings of exocytosis from populations of mast and chromaffin cells using chemoreceptive neuron MOS (CνMOS) transistors. In comparison to previous cell-FET-biosensors, the CνMOS features control (CG), sensing (SG) and floating gates (FG), allows the quiescent point to be independently controlled, is CMOS compatible and physically isolates the transistor channel from the electrolyte for stable long-term recordings. We measured exocytosis from RBL-2H3 mast cells sensitized by IgE (bound to high-affinity surface receptors FcεRI) and stimulated using the antigen DNP-BSA. Quasi-static I-V measurements reflected a slow shift in surface potential () which was dependent on extracellular calcium ([Ca]o) and buffer strength, which suggests sensitivity to protons released during exocytosis. Fluorescent imaging of dextran-labeled vesicle release showed evidence of a similar time course, while un-sensitized cells showed no response to stimulation. Transient recordings revealed fluctuations with a rapid rise and slow decay. Chromaffin cells stimulated with high KCl showed both slow shifts and extracellular action potentials exhibiting biphasic and inverted capacitive waveforms, indicative of varying ion-channel distributions across the cell-transistor junction. Our approach presents a facile method to simultaneously monitor exocytosis and ion channel activity with high temporal sensitivity without the need for redox chemistry. PMID:26686301

  16. Pain sensitivity and tactile spatial acuity are altered in healthy musicians as in chronic pain patients

    PubMed Central

    Zamorano, Anna M.; Riquelme, Inmaculada; Kleber, Boris; Altenmüller, Eckart; Hatem, Samar M.; Montoya, Pedro

    2015-01-01

    Extensive training of repetitive and highly skilled movements, as it occurs in professional classical musicians, may lead to changes in tactile sensitivity and corresponding cortical reorganization of somatosensory cortices. It is also known that professional musicians frequently experience musculoskeletal pain and pain-related symptoms during their careers. The present study aimed at understanding the complex interaction between chronic pain and music training with respect to somatosensory processing. For this purpose, tactile thresholds (mechanical detection, grating orientation, two-point discrimination) and subjective ratings to thermal and pressure pain stimuli were assessed in 17 professional musicians with chronic pain, 30 pain-free musicians, 20 non-musicians with chronic pain, and 18 pain-free non-musicians. We found that pain-free musicians displayed greater touch sensitivity (i.e., lower mechanical detection thresholds), lower tactile spatial acuity (i.e., higher grating orientation thresholds) and increased pain sensitivity to pressure and heat compared to pain-free non-musicians. Moreover, we also found that musicians and non-musicians with chronic pain presented lower tactile spatial acuity and increased pain sensitivity to pressure and heat compared to pain-free non-musicians. The significant increment of pain sensitivity together with decreased spatial discrimination in pain-free musicians and the similarity of results found in chronic pain patients, suggests that the extensive training of repetitive and highly skilled movements in classical musicians could be considered as a risk factor for developing chronic pain, probably due to use-dependent plastic changes elicited in somatosensory pathways. PMID:25610384

  17. High sensitive volumetric imaging of renal microcirculation in vivo using ultrahigh sensitive optical microangiography

    NASA Astrophysics Data System (ADS)

    Zhi, Zhongwei; Jung, Yeongri; Jia, Yali; An, Lin; Wang, Ruikang K.

    2011-03-01

    We present a non-invasive, label-free imaging technique called Ultrahigh Sensitive Optical Microangiography (UHSOMAG) for high sensitive volumetric imaging of renal microcirculation. The UHS-OMAG imaging system is based on spectral domain optical coherence tomography (SD-OCT), which uses a 47000 A-line scan rate CCD camera to perform an imaging speed of 150 frames per second that takes only ~7 seconds to acquire a 3D image. The technique, capable of measuring slow blood flow down to 4 um/s, is sensitive enough to image capillary networks, such as peritubular capillaries and glomerulus within renal cortex. We show superior performance of UHS-OMAG in providing depthresolved volumetric images of rich renal microcirculation. We monitored the dynamics of renal microvasculature during renal ischemia and reperfusion. Obvious reduction of renal microvascular density due to renal ischemia was visualized and quantitatively analyzed. This technique can be helpful for the assessment of chronic kidney disease (CKD) which relates to abnormal microvasculature.

  18. A simple Bird Sensitivity to Oil Index as a management tool in coastal and marine areas subject to oil spills when few biological information is available.

    PubMed

    Romero, A F; Oliveira, M; Abessa, D M S

    2018-03-01

    This study sought to develop a simple index for ranking birds' environmental sensitivity to oil in which birds are used as biological indicators. The study area consisted of both the Santos Estuarine System (SES), and the Laje de Santos Marine State Park (LSMSP), located in Southeastern Brazil. Information on the bird species and their feeding and nesting behaviors were obtained from the literature and were the basis of the sensitivity index created. The SES had a higher number of species, but only about 30% were found to be highly sensitive. The LSMSP presented a much lower number of species, but all of them were considered to be highly sensitive to oil. Due to its simplicity, this index can be employed worldwide as a decision-making tool that may be integrated into other management tools, particularly when robust information on the biology of birds is lacking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. PREVALENCE OF METABOLIC SYNDROME IN YOUNG MEXICANS: A SENSITIVITY ANALYSIS ON ITS COMPONENTS.

    PubMed

    Murguía-Romero, Miguel; Jiménez-Flores, J Rafael; Sigrist-Flores, Santiago C; Tapia-Pancardo, Diana C; Jiménez-Ramos, Arnulfo; Méndez-Cruz, A René; Villalobos-Molina, Rafael

    2015-07-28

    obesity is a worldwide epidemic, and the high prevalence of diabetes type II (DM2) and cardiovascular disease (CVD) is in great part a consequence of that epidemic. Metabolic syndrome is a useful tool to estimate the risk of a young population to evolve to DM2 and CVD. to estimate the MetS prevalence in young Mexicans, and to evaluate each parameter as an independent indicator through a sensitivity analysis. the prevalence of MetS was estimated in 6 063 young of the México City metropolitan area. A sensitivity analysis was conducted to estimate the performance of each one of the components of MetS, as an indicator of the presence of MetS itself. Five statistical of the sensitivity analysis were calculated for each MetS component and the other parameters included: sensitivity, specificity, positive predictive value or precision, negative predictive value, and accuracy. the prevalence of MetS in Mexican young population was estimated to be 13.4%. Waist circumference presented the highest sensitivity (96.8% women; 90.0% men), blood pressure presented the highest specificity for women (97.7%) and glucose for men (91.0%). When all the five statistical are considered triglycerides is the component with the highest values, showing a value of 75% or more in four of them. Differences by sex are detected for averages of all components of MetS in young without alterations. Mexican young are highly prone to acquire MetS: 71% have at least one and up to five MetS parameters altered, and 13.4% of them have MetS. From all the five components of MetS, waist circumference presented the highest sensitivity as a predictor of MetS, and triglycerides is the best parameter if a single factor is to be taken as sole predictor of MetS in Mexican young population, triglycerides is also the parameter with the highest accuracy. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  20. Molecular signatures of transgenerational response to ocean acidification in a species of reef fish

    NASA Astrophysics Data System (ADS)

    Schunter, Celia; Welch, Megan J.; Ryu, Taewoo; Zhang, Huoming; Berumen, Michael L.; Nilsson, Göran E.; Munday, Philip L.; Ravasi, Timothy

    2016-11-01

    The impact of ocean acidification on marine ecosystems will depend on species capacity to adapt. Recent studies show that the behaviour of reef fishes is impaired at projected CO 2 levels; however, individual variation exists that might promote adaptation. Here, we show a clear signature of parental sensitivity to high CO 2 in the brain molecular phenotype of juvenile spiny damselfish, Acanthochromis polyacanthus, primarily driven by circadian rhythm genes. Offspring of CO 2-tolerant and CO 2-sensitive parents were reared at near-future CO 2 (754 μatm) or present-day control levels (414 μatm). By integrating 33 brain transcriptomes and proteomes with a de novo assembled genome we investigate the molecular responses of the fish brain to increased CO 2 and the expression of parental tolerance to high CO 2 in the offspring molecular phenotype. Exposure to high CO 2 resulted in differential regulation of 173 and 62 genes and 109 and 68 proteins in the tolerant and sensitive groups, respectively. Importantly, the majority of differences between offspring of tolerant and sensitive parents occurred in high CO 2 conditions. This transgenerational molecular signature suggests that individual variation in CO 2 sensitivity could facilitate adaptation of fish populations to ocean acidification.

  1. Palladium Gate All Around - Hetero Dielectric -Tunnel FET based highly sensitive Hydrogen Gas Sensor

    NASA Astrophysics Data System (ADS)

    Madan, Jaya; Chaujar, Rishu

    2016-12-01

    The paper presents a novel highly sensitive Hetero-Dielectric-Gate All Around Tunneling FET (HD-GAA-TFET) based Hydrogen Gas Sensor, incorporating the advantages of band to band tunneling (BTBT) mechanism. Here, the Palladium supported silicon dioxide is used as a sensing media and sensing relies on the interaction of hydrogen with Palladium-SiO2-Si. The high surface to volume ratio in the case of cylindrical GAA structure enhances the fortuities for surface reactions between H2 gas and Pd, and thus improves the sensitivity and stability of the sensor. Behaviour of the sensor in presence of hydrogen and at elevated temperatures is discussed. The conduction path of the sensor which is dependent on sensors radius has also been varied for the optimized sensitivity and static performance analysis of the sensor where the proposed design exhibits a superior performance in terms of threshold voltage, subthreshold swing, and band to band tunneling rate. Stability of the sensor with respect to temperature affectability has also been studied, and it is found that the device is reasonably stable and highly sensitive over the bearable temperature range. The successful utilization of HD-GAA-TFET in gas sensors may open a new door for the development of novel nanostructure gas sensing devices.

  2. Shot-noise-limited optical Faraday polarimetry with enhanced laser noise cancelling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jiaming; Department of Physics, Indiana University Purdue University Indianapolis, Indianapolis, Indiana 46202; Luo, Le, E-mail: leluo@iupui.edu

    2014-03-14

    We present a shot-noise-limited measurement of optical Faraday rotations with sub-ten-nanoradian angular sensitivity. This extremely high sensitivity is achieved by using electronic laser noise cancelling and phase sensitive detection. Specially, an electronic laser noise canceller with a common mode rejection ratio of over 100 dB was designed and built for enhanced laser noise cancelling. By measuring the Faraday rotation of ambient air, we demonstrate an angular sensitivity of up to 9.0×10{sup −9} rad/√(Hz), which is limited only by the shot-noise of the photocurrent of the detector. To date, this is the highest angular sensitivity ever reported for Faraday polarimeters in the absencemore » of cavity enhancement. The measured Verdet constant of ambient air, 1.93(3)×10{sup −9}rad/(G cm) at 633 nm wavelength, agrees extremely well with the earlier experiments using high finesse optical cavities. Further, we demonstrate the applications of this sensitive technique in materials science by measuring the Faraday effect of an ultrathin iron film.« less

  3. Absorption of CO2 on Carbon-based Sensors: First-Principle Analysis

    NASA Astrophysics Data System (ADS)

    Tit, Nacir; Elezzi, Mohammed; Abdullah, Hasan; Bahlouli, Hocine; Yamani, Zain

    We present first-principle investigation of the adsorption properties of CO and CO2 molecules on both graphene and carbon nano-tubes (CNTs) in presence of metal catalysis, mainly iron (Fe). The relaxations were carried out using the self-consistent-charge density-functional tight-binding (SCC-DFTB) code in neglect of heat effects. The results show the following: (1) Defected graphene is found to have high sensitivity and high selectivity towards chemisorption of CO molecules and weak physisorption with CO2 molecules. (2) In case of CNTs, the iron ``Fe'' catalyst plays an essential role in capturing CO2 molecules. The Fe ad-atoms on the surface of CNT introduce huge density of states at Fermi level, but the capture of CO2 molecules would reduce that density and consequently reduce conductivity and increase sensitivity. Concerning the selectivity, we have studied the sensitivity versus various gas molecules (such as: O2, N2, H2, H2O, and CO). Furthermore, to assess the effect of catalysis on sensitivity, we have studied the sensitivity of other metal catalysts (such as: Ni, Co, Ti, and Sc). We found that CNT-Fe is highly sensitive and selective towards detection of CO and CO2 molecules. CNT being conductive or semiconducting does not matter much on the adsorption properties.

  4. Three dimensional graphene transistor for ultra-sensitive pH sensing directly in biological media.

    PubMed

    Ameri, Shideh Kabiri; Singh, Pramod K; Sonkusale, Sameer R

    2016-08-31

    In this work, pH sensing directly in biological media using three dimensional liquid gated graphene transistors is presented. The sensor is made of suspended network of graphene coated all around with thin layer of hafnium oxide (HfO2), showing high sensitivity and sensing beyond the Debye-screening limit. The performance of the pH sensor is validated by measuring the pH of isotonic buffered, Dulbecco's phosphate buffered saline (DPBS) solution, and of blood serum derived from Sprague-Dawley rat. The pH sensor shows high sensitivity of 71 ± 7 mV/pH even in high ionic strength media with molarities as high as 289 ± 1 mM. High sensitivity of this device is owing to suspension of three dimensional graphene in electrolyte which provides all around liquid gating of graphene, leading to higher electrostatic coupling efficiency of electrolyte to the channel and higher gating control of transistor channel by ions in the electrolyte. Coating graphene with hafnium oxide film (HfO2) provides binding sites for hydrogen ions, which results in higher sensitivity and sensing beyond the Debye-screening limit. The 3D graphene transistor offers the possibility of real-time pH measurement in biological media without the need for desaltation or sample preparation. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Upper limb strength estimation of physically impaired persons using a musculoskeletal model: A sensitivity analysis.

    PubMed

    Carmichael, Marc G; Liu, Dikai

    2015-01-01

    Sensitivity of upper limb strength calculated from a musculoskeletal model was analyzed, with focus on how the sensitivity is affected when the model is adapted to represent a person with physical impairment. Sensitivity was calculated with respect to four muscle-tendon parameters: muscle peak isometric force, muscle optimal length, muscle pennation, and tendon slack length. Results obtained from a musculoskeletal model of average strength showed highest sensitivity to tendon slack length, followed by muscle optimal length and peak isometric force, which is consistent with existing studies. Muscle pennation angle was relatively insensitive. The analysis was repeated after adapting the musculoskeletal model to represent persons with varying severities of physical impairment. Results showed that utilizing the weakened model significantly increased the sensitivity of the calculated strength at the hand, with parameters previously insensitive becoming highly sensitive. This increased sensitivity presents a significant challenge in applications utilizing musculoskeletal models to represent impaired individuals.

  6. Review of high-sensitivity Radon studies

    NASA Astrophysics Data System (ADS)

    Wojcik, M.; Zuzel, G.; Simgen, H.

    2017-10-01

    A challenge in many present cutting-edge particle physics experiments is the stringent requirements in terms of radioactive background. In peculiar, the prevention of Radon, a radioactive noble gas, which occurs from ambient air and it is also released by emanation from the omnipresent progenitor Radium. In this paper we review various high-sensitivity Radon detection techniques and approaches, applied in the experiments looking for rare nuclear processes happening at low energies. They allow to identify, quantitatively measure and finally suppress the numerous sources of Radon in the detectors’ components and plants.

  7. Very high energy gamma-ray astronomy with HAWC

    NASA Astrophysics Data System (ADS)

    López-Coto, R.; HAWC Collaboration

    2017-12-01

    The High Altitude Water Cherenkov (HAWC) observatory is an air-shower array located in Mexico. It is sensitive to the highest energy photons we detect at the Earth, reaching energies of several tens of TeV. The observatory was completed more than one year ago and we are presenting in this contribution the first results about its performance. We also show the results of the first-year survey, the first flaring events detected by the observatory, its sensitivity to extended sources and the plans for the upgrade that is currently taking place.

  8. Development of a highly-sensitive Penning ionization electron spectrometer using the magnetic bottle effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ota, Masahiro; Ishiguro, Yuki; Nakajima, Yutaro

    2016-02-01

    This paper reports on a highly-sensitive retarding-type electron spectrometer for a continuous source of electrons, in which the electron collection efficiency is increased by utilizing the magnetic bottle effect. This study demonstrates an application to Penning ionization electron spectroscopy using collisional ionization with metastable He*(2{sup 3}S) atoms. Technical details and performances of the instrument are presented. This spectrometer can be used for studies of functional molecules and assemblies, and exterior electron densities are expected to be selectively observed by the Penning ionization.

  9. CBT for high anxiety sensitivity: alcohol outcomes.

    PubMed

    Olthuis, Janine V; Watt, Margo C; Mackinnon, Sean P; Stewart, Sherry H

    2015-07-01

    High anxiety sensitivity (AS) has been associated with greater alcohol consumption and alcohol-related problems as well as greater sensitivity to the anxiety-reducing effects of alcohol and greater risky negative reinforcement motives for drinking. The present study reported on the alcohol-related outcomes of a telephone-delivered cognitive behavioral treatment (CBT) designed to reduce high AS. Eighty individuals with high AS (M age=36 years; 79% women; 76% Caucasian) seeking treatment for their AS-related concerns participated in the study and were randomly assigned to an eight week telephone CBT program or a waiting list control. Participants completed measures of drinking motives and problem drinking at pre- and post-treatment. Multilevel modeling showed that the treatment was successful in reducing AS. The treatment also resulted in specific reductions in drinking to cope with anxiety motives as well as physical alcohol-related problems. Mediated moderation analyses showed treatment-related changes in AS mediated changes in drinking to cope with anxiety motives. Changes in drinking to cope with anxiety motives mediated changes in physical alcohol-related problems. Results of the present study suggest that an AS-targeted intervention may have implications for reducing risky alcohol use cognitions and behaviors. Further research is needed in a sample of problem drinkers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Sensitization to caffeine and cross-sensitization to amphetamine: influence of individual response to caffeine.

    PubMed

    Simola, Nicola; Cauli, Omar; Morelli, Micaela

    2006-09-15

    The present study evaluated the ability of a subchronic intermittent administration of caffeine to induce a sensitized motor response and correlated the individual susceptibility of rats to acute caffeine to the development of sensitization. Moreover, individual susceptibility to caffeine and development of motor behaviour sensitization were correlated to the behavioural response obtained after a challenge with amphetamine. To this end, rats were subdivided in "low" and "high" responders according to their individual susceptibility to acute caffeine established on the basis of the motor activity observed after the first caffeine administration. "Low" and "high" responder rats were then repeatedly and intermittently treated with caffeine (15 mg/kg, i.p.), or vehicle, every other day for fourteen days. Three days after treatment discontinuation, behavioural activation induced by acute amphetamine (0.5 mg/kg, s.c.) was measured in vehicle- and caffeine-pretreated rats. Subchronic caffeine resulted in motor sensitization of a variable degree among rats and no difference were observed between "low" and "high" responders. Moreover, caffeine pretreatment potentiated the behavioural effects of amphetamine according to the degree of caffeine sensitization but not to individual susceptibility to acute caffeine. These results demonstrate that individual susceptibility to acute caffeine does not influence the modifications in caffeine motor effects produced by its subchronic administration and does not affect the enhancement of acute behavioural effects of amphetamine in caffeine-pretreated rats, rather sensitization to subchronic caffeine administration critically influences the behavioural effects of amphetamine.

  11. Advances in the Diagnosis and Treatment of PCOS.

    PubMed

    Carmina, Enrico; Guastella, Ettore; Longo, Rosa Alba

    2016-01-01

    While the Rotterdam criteria look simple and easy to follow, in clinical practice diagnosis of PCOS may be problematic because of the use of inaccurate commercial androgen assays. Progresses in ovarian ultrasound and in AMH measurement have modified the way to make the diagnosis of PCOS and an update of Rotterdam criteria may be necessary. In classic severe form of PCOS, ovarian follicle count is a very reliable diagnostic criterion but AMH measurement may also present high diagnostic specificity and sensitivity. This finding is particularly important when no clinical signs of androgen excess are present and only commercial assays for androgen measurement are available. At the contrary, in mild PCOS phenotypes, sensitivity of AMH measurement is too low whileFNPO count maintains a high diagnostic sensitivity. However, at least in ovulatory hyperandrogenic PCOS phenotype, increased AMH values in association with enlarged ovarian size permit the diagnosis of ovulatory PCOS in 85% of these patients. Treatment of PCOS women has to be directed to get fertility or in patients not seeking fertility to solve or attenuate the psychological implications of androgen excess and of irregular menses and the risk of endometrial hyperplasia. The therapeutic protocols that are used in our department are presented.

  12. B cell repertoires in HLA-sensitized kidney transplant candidates undergoing desensitization therapy.

    PubMed

    Beausang, John F; Fan, H Christina; Sit, Rene; Hutchins, Maria U; Jirage, Kshama; Curtis, Rachael; Hutchins, Edward; Quake, Stephen R; Yabu, Julie M

    2017-01-13

    Kidney transplantation is the most effective treatment for end-stage renal disease. Sensitization refers to pre-existing antibodies against human leukocyte antigen (HLA) protein and remains a major barrier to successful transplantation. Despite implementation of desensitization strategies, many candidates fail to respond. Our objective was to determine whether measuring B cell repertoires could differentiate candidates that respond to desensitization therapy. We developed an assay based on high-throughput DNA sequencing of the variable domain of the heavy chain of immunoglobulin genes to measure changes in B cell repertoires in 19 highly HLA-sensitized kidney transplant candidates undergoing desensitization and 7 controls with low to moderate HLA sensitization levels. Responders to desensitization had a decrease of 5% points or greater in cumulated calculated panel reactive antibody (cPRA) levels, and non-responders had no decrease in cPRA. Dominant B cell clones were not observed in highly sensitized candidates, suggesting that the B cells responsible for sensitization are either not present in peripheral blood or present at comparable levels to other circulating B cells. Candidates that responded to desensitization therapy had pre-treatment repertoires composed of a larger fraction of class-switched (IgG and IgA) isotypes compared to non-responding candidates. After B cell depleting therapy, the proportion of switched isotypes increased and the mutation frequencies of the remaining non-switched isotypes (IgM and IgD) increased in both responders and non-responders, perhaps representing a shift in the repertoire towards memory B cells or plasmablasts. Conversely, after transplantation, non-switched isotypes with fewer mutations increased, suggesting a shift in the repertoire towards naïve B cells. Relative abundance of different B cell isotypes is strongly perturbed by desensitization therapy and transplantation, potentially reflecting changes in the relative abundance of memory and naïve B cell compartments. Candidates that responded to therapy experienced similar changes to those that did not respond. Further studies are required to understand differences between these two groups of highly sensitized kidney transplant candidates.

  13. Highly Sensitive Measurements of 222Rn Diffusion and Emanation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zuzel, Grzegorz

    Highly sensitive techniques for determination of the 222Rn emanation from solids and diffusion through different membranes are presented. 222Rn and its daughters are measured via the alpha decays in special proportional counters at the absolute sensitivity of {approx}30 {mu}Bq. Radon diffusion can be measured at the level of {approx}10-13 cm2/s. Several samples were examined, e.g. stainless steel, teflon, various gaskets (emanation and diffusion measurements) and tanks. A combination of measurements of the 222Rn diffusion and emanation of thin nylon foils (used in the Borexino experiment) allowed the determination of 226Ra in the materials of interest at the level of {approx}10-12more » g/g 238U-equivalent.« less

  14. High sensitivity spectroscopic and thermal characterization of cooling efficiency for optical refrigeration materials

    NASA Astrophysics Data System (ADS)

    Melgaard, Seth D.; Seletskiy, Denis V.; Di Lieto, Alberto; Tonelli, Mauro; Sheik-Bahae, Mansoor

    2012-03-01

    Since recent demonstration of cryogenic optical refrigeration, a need for reliable characterization tools of cooling performance of different materials is in high demand. We present our experimental apparatus that allows for temperature and wavelength dependent characterization of the materials' cooling efficiency and is based on highly sensitive spectral differencing technique or two-band differential spectral metrology (2B-DSM). First characterization of a 5% w.t. ytterbium-doped YLF crystal showed quantitative agreement with the current laser cooling model, as well as measured a minimum achievable temperature (MAT) at 110 K. Other materials and ion concentrations are also investigated and reported here.

  15. High-sensitivity, high-selectivity detection of chemical warfare agents

    NASA Astrophysics Data System (ADS)

    Pushkarsky, Michael B.; Webber, Michael E.; Macdonald, Tyson; Patel, C. Kumar N.

    2006-01-01

    We report high-sensitivity detection of chemical warfare agents (nerve gases) with very low probability of false positives (PFP). We demonstrate a detection threshold of 1.2ppb (7.7μg/m3 equivalent of Sarin) with a PFP of <1:106 in the presence of many interfering gases present in an urban environment through the detection of diisopropyl methylphosphonate, an accepted relatively harmless surrogate for the nerve agents. For the current measurement time of ˜60s, a PFP of 1:106 corresponds to one false alarm approximately every 23months. The demonstrated performance satisfies most current homeland and military security requirements.

  16. GaAs-based resonant tunneling diode (RTD) epitaxy on Si for highly sensitive strain gauge applications.

    PubMed

    Li, Jie; Guo, Hao; Liu, Jun; Tang, Jun; Ni, Haiqiao; Shi, Yunbo; Xue, Chenyang; Niu, Zhichuan; Zhang, Wendong; Li, Mifeng; Yu, Ying

    2013-05-08

    As a highly sensitive strain gauge element, GaAs-based resonant tunneling diode (RTD) has already been applied in microelectromechanical system (MEMS) sensors. Due to poor mechanical properties and high cost, GaAs-based material has been limited in applications as the substrate for MEMS. In this work, we present a method to fabricate the GaAs-based RTD on Si substrate. From the experimental results, it can be concluded that the piezoresistive coefficient achieved with this method reached 3.42 × 10-9 m2/N, which is about an order of magnitude higher than the Si-based semiconductor piezoresistors.

  17. Highly sensitive nanostructure SnO2 based gas sensor for environmental pollutants

    NASA Astrophysics Data System (ADS)

    Korgaokar, Sushil; Moradiya, Meet; Prajapati, Om; Thakkar, Pranav; Pala, Jay; Savaliya, Chirag; Parikh, Sachin; Markna, J. H.

    2017-05-01

    A major quantity of pollutants are produced from industries and vehicles in the form of gas. New approaches are needed to solve well-known environmental pollutants like CO, CO2, NO2, SOx. Therefore detection with effective gas sensors is a vital part of pollution prevention efforts. There is a need to develop fast, rapid, cost-effective, highly sensitive, low power, and non-intrusive rugged sensors that can be easily installed. In the present study, nanostructured SnO2 used as a sensitive material in the devices and synthesized using hydrothermal process. The detailed development of the fabrication of SnO2 nanostructures gas sensor is described, which shows the remarkable change in the sensing properties with varying particle size. Additionally, we have used X-ray diffraction, scanning electron microscopy (SEM) for characterization and carefully examined the relative parameters like response magnitude (sensitivity) and selectivity of SnO2 nano structures with different particle size.

  18. Highly Sensitive Hot-Wire Anemometry Based on Macro-Sized Double-Walled Carbon Nanotube Strands.

    PubMed

    Wang, Dingqu; Xiong, Wei; Zhou, Zhaoying; Zhu, Rong; Yang, Xing; Li, Weihua; Jiang, Yueyuan; Zhang, Yajun

    2017-08-01

    This paper presents a highly sensitive flow-rate sensor with carbon nanotubes (CNTs) as sensing elements. The sensor uses micro-size centimeters long double-walled CNT (DWCNT) strands as hot-wires to sense fluid velocity. In the theoretical analysis, the sensitivity of the sensor is demonstrated to be positively related to the ratio of its surface. We assemble the flow sensor by suspending the DWCNT strand directly on two tungsten prongs and dripping a small amount of silver glue onto each contact between the DWCNT and the prongs. The DWCNT exhibits a positive TCR of 1980 ppm/K. The self-heating effect on the DWCNT was observed while constant current was applied between the two prongs. This sensor can evidently respond to flow rate, and requires only several milliwatts to operate. We have, thus far, demonstrated that the CNT-based flow sensor has better sensitivity than the Pt-coated DWCNT sensor.

  19. Enhancement in sensitivity of graphene-based zinc oxide assisted bimetallic surface plasmon resonance (SPR) biosensor

    NASA Astrophysics Data System (ADS)

    Kumar, Rajeev; Kushwaha, Angad S.; Srivastava, Monika; Mishra, H.; Srivastava, S. K.

    2018-03-01

    In the present communication, a highly sensitive surface plasmon resonance (SPR) biosensor with Kretschmann configuration having alternate layers, prism/zinc oxide/silver/gold/graphene/biomolecules (ss-DNA) is presented. The optimization of the proposed configuration has been accomplished by keeping the constant thickness of zinc oxide (32 nm), silver (32 nm), graphene (0.34 nm) layer and biomolecules (100 nm) for different values of gold layer thickness (1, 3 and 5 nm). The sensitivity of the proposed SPR biosensor has been demonstrated for a number of design parameters such as gold layer thickness, number of graphene layer, refractive index of biomolecules and the thickness of biomolecules layer. SPR biosensor with optimized geometry has greater sensitivity (66 deg/RIU) than the conventional (52 deg/RIU) as well as other graphene-based (53.2 deg/RIU) SPR biosensor. The effect of zinc oxide layer thickness on the sensitivity of SPR biosensor has also been analysed. From the analysis, it is found that the sensitivity increases significantly by increasing the thickness of zinc oxide layer. It means zinc oxide intermediate layer plays an important role to improve the sensitivity of the biosensor. The sensitivity of SPR biosensor also increases by increasing the number of graphene layer (upto nine layer).

  20. N-terminal pro-brain natriuretic peptide and high-sensitivity troponin in the evaluation of acute chest pain of uncertain etiology. A PITAGORAS substudy.

    PubMed

    Sanchis, Juan; Bardají, Alfredo; Bosch, Xavier; Loma-Osorio, Pablo; Marín, Francisco; Sánchez, Pedro L; Calvo, Francisco; Avanzas, Pablo; Hernández, Carolina; Serrano, Silvia; Carratalá, Arturo; Barrabés, José A

    2013-07-01

    High-sensitivity troponin assays have improved the diagnosis of acute coronary syndrome in patients presenting with chest pain and normal troponin levels as measured by conventional assays. Our aim was to investigate whether N-terminal pro-brain natriuretic peptide provides additional information to troponin determination in these patients. A total of 398 patients, included in the PITAGORAS study, presenting to the emergency department with chest pain and normal troponin levels as measured by conventional assay in 2 serial samples (on arrival and 6 h to 8h later) were studied. The samples were also analyzed in a central laboratory for high-sensitivity troponin T (both samples) and for N-terminal pro-brain natriuretic peptide (second sample). The endpoints were diagnosis of acute coronary syndrome and the composite endpoint of in-hospital revascularization or a 30-day cardiac event. Acute coronary syndrome was adjudicated to 79 patients (20%) and the composite endpoint to 59 (15%). When the N-terminal pro-brain natriuretic peptide quartile increased, the diagnosis of acute coronary syndrome also increased (12%, 16%, 23% and 29%; P=.01), as did the risk of the composite endpoint (6%, 13%, 16% and 24%; P=.004). N-terminal pro-brain natriuretic peptide elevation (>125ng/L) was associated with both endpoints (relative risk= 2.0; 95% confidence interval, 1.2-3.3; P=.02; relative risk=2.4; 95% confidence interval, 1.4-4.2; P=.004). However, in the multivariable models adjusted by clinical and electrocardiographic data, a predictive value was found for high-sensitivity T troponin but not for N-terminal pro-brain natriuretic peptide. In low-risk patients with chest pain of uncertain etiology evaluated using high-sensitivity T troponin, N-terminal pro-brain natriuretic peptide does not contribute additional predictive value to diagnosis or the prediction of short-term outcomes. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  1. A practical and highly sensitive C3N4-TYR fluorescent probe for convenient detection of dopamine

    NASA Astrophysics Data System (ADS)

    Li, Hao; Yang, Manman; Liu, Juan; Zhang, Yalin; Yang, Yanmei; Huang, Hui; Liu, Yang; Kang, Zhenhui

    2015-07-01

    The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules.The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr03316k

  2. High pressure liquid and gaseous oxygen impact sensitivity evaluation of materials for use at Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.

    1976-01-01

    The sensitivity of materials in contact with gaseous oxygen (GOX) or liquid oxygen (LOX) was examined. Specifically, the reactivity of materials when in contact with GOX or LOX if subjected to such stimuli as mechanical impact, adiabatic compression (pneumatic impact), or an electrical discharge in the form of a spark were examined. Generally, materials are more sensitive in gaseous oxygen than in liquid oxygen and impact sensitivity is known to increase with increasing pressure. Materials presently being used or considered for use in oxygen systems at KSC were evaluated. Results are given in tabular form.

  3. Facial emotion expression recognition by children at familial risk for depression: High risk boys are oversensitive to sadness

    PubMed Central

    Lopez-Duran, Nestor L.; Kuhlman, Kate R.; George, Charles; Kovacs, Maria

    2012-01-01

    In the present study we examined perceptual sensitivity to facial expressions of sadness among children at familial-risk for depression (N = 64) and low-risk peers (N = 40) between the ages 7 and 13(Mage = 9.51; SD = 2.27). Participants were presented with pictures of facial expressions that varied in emotional intensity from neutral to full-intensity sadness or anger (i.e., emotion recognition), or pictures of faces morphing from anger to sadness (emotion discrimination). After each picture was presented, children indicated whether the face showed a specific emotion (i.e., sadness, anger) or no emotion at all (neutral). In the emotion recognition task, boys (but not girls) at familial-risk for depression identified sadness at significantly lower levels of emotional intensity than did their low-risk peers. The high and low-risk groups did not differ with regard to identification of anger. In the emotion discrimination task, both groups displayed over-identification of sadness in ambiguous mixed faces but high-risk youth were less likely to show this labeling bias than their peers. Our findings are consistent with the hypothesis that enhanced perceptual sensitivity to subtle traces of sadness in facial expressions may be a potential mechanism of risk among boys at familial-risk for depression. This enhanced perceptual sensitivity does not appear to be due to biases in the labeling of ambiguous faces. PMID:23106941

  4. Post-buckling of a pressured biopolymer spherical shell with the mode interaction

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Ru, C. Q.

    2018-03-01

    Imperfection sensitivity is essential for mechanical behaviour of biopolymer shells characterized by high geometric heterogeneity. The present work studies initial post-buckling and imperfection sensitivity of a pressured biopolymer spherical shell based on non-axisymmetric buckling modes and associated mode interaction. Our results indicate that for biopolymer spherical shells with moderate radius-to-thickness ratio (say, less than 30) and smaller effective bending thickness (say, less than 0.2 times average shell thickness), the imperfection sensitivity predicted based on the axisymmetric mode without the mode interaction is close to the present results based on non-axisymmetric modes with the mode interaction with a small (typically, less than 10%) relative errors. However, for biopolymer spherical shells with larger effective bending thickness, the maximum load an imperfect shell can sustain predicted by the present non-axisymmetric analysis can be significantly (typically, around 30%) lower than those predicted based on the axisymmetric mode without the mode interaction. In such cases, a more accurate non-axisymmetric analysis with the mode interaction, as given in the present work, is required for imperfection sensitivity of pressured buckling of biopolymer spherical shells. Finally, the implications of the present study to two specific types of biopolymer spherical shells (viral capsids and ultrasound contrast agents) are discussed.

  5. Highly sensitive quantitative PCR for the detection and differentiation of Pseudogymnoascus destructans and other Pseudogymnoascus species.

    PubMed

    Shuey, Megan M; Drees, Kevin P; Lindner, Daniel L; Keim, Paul; Foster, Jeffrey T

    2014-03-01

    White-nose syndrome is a fungal disease that has decimated bat populations across eastern North America. Identification of the etiologic agent, Pseudogymnoascus destructans (formerly Geomyces destructans), in environmental samples is essential to proposed management plans. A major challenge is the presence of closely related species, which are ubiquitous in many soils and cave sediments and often present in high abundance. We present a dual-probe real-time quantitative PCR assay capable of detecting and differentiating P. destructans from closely related fungi in environmental samples from North America. The assay, based on a single nucleotide polymorphism (SNP) specific to P. destructans, is capable of rapid low-level detection from various sampling media, including sediment, fecal samples, wing biopsy specimens, and skin swabs. This method is a highly sensitive, high-throughput method for identifying P. destructans, other Pseudogymnoascus spp., and Geomyces spp. in the environment, providing a fundamental component of research and risk assessment for addressing this disease, as well as other ecological and mycological work on related fungi.

  6. Effects of anxiety sensitivity and expectations on the modulation of the startle eyeblink response during a caffeine challenge.

    PubMed

    Benke, Christoph; Blumenthal, Terry D; Modeß, Christiane; Hamm, Alfons O; Pané-Farré, Christiane A

    2015-09-01

    The way in which the tendency to fear somatic arousal sensations (anxiety sensitivity), in interaction with the created expectations regarding arousal induction, might affect defensive responding to a symptom provocation challenge is not yet understood. The present study investigated the effect of anxiety sensitivity on autonomic arousal, startle eyeblink responses, and reported arousal and alertness to expected vs. unexpected caffeine consumption. To create a match/mismatch of expected and experienced arousal, high and low anxiety sensitive participants received caffeine vs. no drug either mixed in coffee (expectation of arousal induction) or in bitter lemon soda (no expectation of arousal induction) on four separate occasions. Autonomic arousal (heart rate, skin conductance level), respiration (end-tidal CO2, minute ventilation), defensive reflex responses (startle eyeblink), and reported arousal and alertness were recorded prior to, immediately and 30 min after beverage ingestion. Caffeine increased ventilation, autonomic arousal, and startle response magnitudes. Both groups showed comparable levels of autonomic and respiratory responses. The startle eyeblink responses were decreased when caffeine-induced arousal occurred unexpectedly, e.g., after administering caffeine in bitter lemon. This effect was more accentuated in high anxiety sensitive persons. Moreover, in high anxiety sensitive persons, the expectation of arousal (coffee consumption) led to higher subjective alertness when administering caffeine and increased arousal even if no drug was consumed. Unexpected symptom provocation leads to increased attention allocation toward feared arousal sensations in high anxiety sensitive persons. This finding broadens our understanding of modulatory mechanisms in defensive responding to bodily symptoms.

  7. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Zhao; Gao, Kun; Chen, Jian

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using themore » error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.« less

  8. A simple method to measure critical angles for high-sensitivity differential refractometry.

    PubMed

    Zilio, S C

    2012-01-16

    A total internal reflection-based differencial refractometer, capable of measuring the real and imaginary parts of the complex refractive index in real time, is presented. The device takes advantage of the phase difference acquired by s- and p-polarized light to generate an easily detectable minimum at the reflected profile. The method allows to sensitively measuring transparent and turbid liquid samples.

  9. The sensitivity of gas sensor based on single ZnO nanowire modulated by helium ion radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, L.; Lu, H. B.; Li, J. C.

    2007-10-22

    In this letter, we present a gas sensor using a single ZnO nanowire as a sensing unit. This ZnO nanowire-based sensor has quick and high sensitive response to H{sub 2}S in air at room temperature. It has also been found that the gas sensitivity of the ZnO nanowires could be modulated and enhanced by He{sup +} implantation at an appropriate dose. A possible explanation is given based on the modulation model of the depletion layer.

  10. Social and attentional aspects of echolalia in highly echolalic mentally retarded persons.

    PubMed

    Campbell, B; Grieve, R

    1978-01-01

    Echolalia was examined in a sample of highly echolalic mentally retarded individuals. When presented with a standard set of questions, under conditions differing in appropriateness for exchange of discourse (e.g., questions presented with examiner and patient face-to-face vs. questions presented with the examiner's face averted vs. questions addressed towards another person sitting silently beside the patient), subjects' frequency of echolalia varied. Besides showing considerable sensitivity to aspects of discourse exchange, subjects exhibited some limited capacity for processing linguistic information.

  11. [Spectrum and drug sensitivity of pathogenic bacteria in children with nephrotic syndrome complicated by urinary tract infection: an analysis of 97 cases].

    PubMed

    Song, Shao-Na; Zhang, Bi-Li; Wang, Wen-Hong; Zhang, Xuan

    2012-09-01

    To investigate the spectrum and drug sensitivity of pathogenic bacteria in children with nephrotic syndrome (NS) complicated by urinary tract infection (UTI). A retrospective analysis was performed on the spectrum and drug sensitivity of pathogenic bacteria in 97 children with NS complicated by UTI, who hospitalized from January to December, 2011. The incidence of UTI in children with NS was 36.5%. It was significantly more common in children with recurrent NS than in those with primary NS (44.0% vs 31.9%; P<0.05). These cases mainly presented with asymptomatic bacteriuria. Enterococcus was the most common pathogenic bacteria (50.5%), including Enterococcus faecium (29.4%) and Enterococcus faecalis (21.1%), followed by Gram-negative bacteria, such as Escherichia coli (15.6%) and Klebsiella pneumoniae (14.7%). Enterococcus was highly sensitive to nitrofurantoin, vacomycin and linezolid, but was highly resistant to tetracycline and moxifloxacin. More multi-resistant strains were detected in Enterococcus faecium than in Enterococcus faecalis (72% vs 17%; P<0.05). Escherichia coli and Klebsiella pneumoniae were highly sensitive to amikacin, imipenem and piperacillin/tazobactam. Of the Gram-negative bacteria, 25% produced extended spectrum β-lactamases (ESBLs). ESBLs-producing bacteria had 100% sensitivity to imipenem, amikacin and piperacillin/tazobactam but were highly resistant to ampicillin, cefazolin and ceftriaxone. Children with recurrent NS are more susceptible to UTI than those with primary NS. Enterococcus is becoming major pathogenic bacteria for UTI in children with NS and has relatively high drug resistance, and most strains of Enterococcus faecium are multi-resistant.

  12. Eight-Channel AC Magnetosusceptometer of Magnetic Nanoparticles for High-Throughput and Ultra-High-Sensitivity Immunoassay

    PubMed Central

    Chieh, Jen-Jie; Wei, Wen-Chun; Chen, Hsin-Hsein; Lee, Yen-Fu; Lin, Feng-Chun; Chiang, Ming-Hsien; Chiu, Ming-Jang; Horng, Herng-Er; Yang, Shieh-Yueh

    2018-01-01

    An alternating-current magnetosusceptometer of antibody-functionalized magnetic nanoparticles (MNPs) was developed for immunomagnetic reduction (IMR). A high-sensitivity, high-critical-temperature superconducting quantum interference device was used in the magnetosusceptometer. Minute levels of biomarkers of early-stage neurodegeneration diseases were detectable in serum, but measuring each biomarker required approximately 4 h. Hence, an eight-channel platform was developed in this study to fit minimal screening requirements for Alzheimer’s disease. Two consistent results were measured for three biomarkers, namely Aβ40, Aβ42, and tau protein, per human specimen. This paper presents the instrument configuration as well as critical characteristics, such as the low noise level variations among channels, a high signal-to-noise ratio, and the coefficient of variation for the biomarkers’ IMR values. The instrument’s ultrahigh sensitivity levels for the three biomarkers and the substantially shorter total measurement time in comparison with the previous single- and four-channels platforms were also demonstrated in this study. Thus, the eight-channel instrument may serve as a powerful tool for clinical high-throughput screening of Alzheimer’s disease. PMID:29601532

  13. Considerations in high resolution skeletal muscle DTI using single-shot EPI with stimulated echo preparation and SENSE

    PubMed Central

    Karampinos, Dimitrios C.; Banerjee, Suchandrima; King, Kevin F.; Link, Thomas M.; Majumdar, Sharmila

    2011-01-01

    Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can non-invasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion weighted (DW)-EPI can be hindered by the inherently low SNR of muscle DW-EPI due to the short muscle T2 and the high sensitivity of single-shot EPI to off-resonance effects and T2* blurring. In the present work, eddy-current compensated diffusion-weighted stimulated echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and reduce the sensitivity to distortions and T2* blurring in high resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed for optimizing the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B0-induced distortions, T2* blurring effects and tissue incoherent motion effects. Based on the selected parameters in a high resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In vivo results show that high resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T2* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from reducing partial volume effects on resolving multi-pennate muscles and muscles with small cross sections in calf muscle DTI. PMID:22081519

  14. Microelectromechanical systems for experimental physics and optical telecommunications

    NASA Astrophysics Data System (ADS)

    Aksyuk, Vladimir Anatolyevich

    1999-12-01

    Micro-Electro-Mechanical Systems (MEMS) are an emerging technology, which, when applied to the field of physical sensors, offers not only an obvious advantage of being small and cheap, but more importantly, provides some unique experimental opportunities. These are based on the way physical properties scale with decreasing size. This thesis discusses these basic principles and corresponding advantages and limitations of MEMS technology and presents several experiments in which micromachines are used to do physical measurements that could not be done before. Three types of micromechanical magnetometers are demonstrated. When compared to the state of the art traditional techniques they show greater sensitivity, faster response and can be applied over a wider range of experimental conditions. The high-Q micromechanical torsional oscillator magnetometer is used to observe mesoscopic vortex physics, including single flux lines penetrating into a type-II superconductor just above the first critical field. The Faraday balance ``Trampoline'' magnetometer combines high sensitivity, high bandwidth and can be operated in a wide temperature range. It is used in both high pulsed magnetic fields to record deHaas-vanAlphen oscillations and in DC magnetic fields for magnetization measurements at temperatures down to 100mK. The high sensitivity DC torque magnetometer offers yet higher sensitivity and can be used for a variety of magnetization measurements. Several other MEMS devices for physics and telecommunications applications are presented, including a micromachined near field scanning optical microscope, MEMS fiberoptic switches and large-area large-angle scanners. They provide examples of complex functionality that can be achieved with micromechanics by combining sensors with inherently low-power electrostatic actuators. The optically powered optical power limiter demonstrates the possibility of operating MEMS with optical rather than electrical power.

  15. CRDS with a VECSEL for broad-band high sensitivity spectroscopy in the 2.3 μm window.

    PubMed

    Čermák, P; Chomet, B; Ferrieres, L; Vasilchenko, S; Mondelain, D; Kassi, S; Campargue, A; Denet, S; Lecocq, V; Myara, M; Cerutti, L; Garnache, A

    2016-08-01

    The integration of an industry ready packaged Sb-based Vertical-External-Cavity Surface-Emitting-Laser (VECSEL) into a Cavity Ring Down Spectrometer (CRDS) is presented. The instrument operates in the important 2.3 μm atmospheric transparency window and provides a high sensitivity (minimum detectable absorption of 9 × 10(-11) cm(-1)) over a wide spectra range. The VECSEL performances combine a large continuous tunability over 120 cm(-1) around 4300 cm(-1) together with a powerful (∼5 mW) TEM00 diffraction limited beam and linewidth at MHz level (for 1 ms of integration time). The achieved performances are illustrated by high sensitivity recordings of the very weak absorption spectrum of water vapor in the region. The developed method gives potential access to the 2-2.7 μm range for CRDS.

  16. Highly sensitive piezo-resistive graphite nanoplatelet-carbon nanotube hybrids/polydimethylsilicone composites with improved conductive network construction.

    PubMed

    Zhao, Hang; Bai, Jinbo

    2015-05-13

    The constructions of internal conductive network are dependent on microstructures of conductive fillers, determining various electrical performances of composites. Here, we present the advanced graphite nanoplatelet-carbon nanotube hybrids/polydimethylsilicone (GCHs/PDMS) composites with high piezo-resistive performance. GCH particles were synthesized by the catalyst chemical vapor deposition approach. The synthesized GCHs can be well dispersed in the matrix through the mechanical blending process. Due to the exfoliated GNP and aligned CNTs coupling structure, the flexible composite shows an ultralow percolation threshold (0.64 vol %) and high piezo-resistive sensitivity (gauge factor ∼ 10(3) and pressure sensitivity ∼ 0.6 kPa(-1)). Slight motions of finger can be detected and distinguished accurately using the composite film as a typical wearable sensor. These results indicate that designing the internal conductive network could be a reasonable strategy to improve the piezo-resistive performance of composites.

  17. Cobalt oxide nanosheets wrapped onto nickel foam for non-enzymatic detection of glucose

    NASA Astrophysics Data System (ADS)

    Meng, Shangjun; Wu, Meiyan; Wang, Qian; Dai, Ziyang; Si, Weili; Huang, Wei; Dong, Xiaochen

    2016-08-01

    Ultra-sensitive and highly selective detection of glucose is essential for the clinical diagnosis of diabetes. In this paper, an ultra-sensitive glucose sensor was successfully fabricated based on cobalt oxide (Co3O4) nanosheets directly grown on nickel foam through a simple hydrothermal method. Characterizations indicated that the Co3O4 nanosheets are completely and uniformly wrapped onto the surface of nickel foam to form a three-dimensional heterostructure. The resulting self-standing electrochemical electrode presents a high performance for the non-enzymatic detection of glucose, including short response time (<10 s), ultra-sensitivity (12.97 mA mM-1 cm-2), excellent selectivity and low detection limit (0.058 μM, S/N = 3). These results indicate that Co3O4 nanosheets wrapped onto nickel foam are a low-cost, practical, and high performance electrochemical electrode for bio sensing.

  18. CRDS with a VECSEL for broad-band high sensitivity spectroscopy in the 2.3 μm window

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Čermák, P., E-mail: cermak@fmph.uniba.sk; CNRS, LIPhy, UMR 5588, F-38000 Grenoble; Department of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská Dolina, 842 48 Bratislava

    2016-08-15

    The integration of an industry ready packaged Sb-based Vertical-External-Cavity Surface-Emitting-Laser (VECSEL) into a Cavity Ring Down Spectrometer (CRDS) is presented. The instrument operates in the important 2.3 μm atmospheric transparency window and provides a high sensitivity (minimum detectable absorption of 9 × 10{sup −11} cm{sup −1}) over a wide spectra range. The VECSEL performances combine a large continuous tunability over 120 cm{sup −1} around 4300 cm{sup −1} together with a powerful (∼5 mW) TEM{sub 00} diffraction limited beam and linewidth at MHz level (for 1 ms of integration time). The achieved performances are illustrated by high sensitivity recordings of themore » very weak absorption spectrum of water vapor in the region. The developed method gives potential access to the 2-2.7 μm range for CRDS.« less

  19. Hollow fiber surface plasmon resonance sensor for the detection of liquid with high refractive index.

    PubMed

    Liu, Bing-Hong; Jiang, Yong-Xiang; Zhu, Xiao-Song; Tang, Xiao-Li; Shi, Yi-Wei

    2013-12-30

    A new kind of surface plasmon resonance (SPR) sensor based on silver-coated hollow fiber (HF) structure for the detection of liquids with high refractive index (RI) is presented. Liquid sensed medium with high RI is filled in the hollow core of the HF and its RI can be detected by measuring the transmission spectra of the HF SPR sensor. The designed sensors with different silver thicknesses are fabricated and the transmission spectra for filled liquids with different RI are measured to investigate the performances of the sensors. Theoretical analysis is also carried out to evaluate the performance. The simulation results agree well with the experimental results. Factors that might affect sensitivity and detection accuracy of the sensor are discussed. The highest sensitivity achieved is 6,607 nm/RIU, which is comparable to the sensitivities of the other reported fiber SPR sensors.

  20. A novel approach to mask defect inspection

    NASA Astrophysics Data System (ADS)

    Sagiv, Amir; Shirman, Yuri; Mangan, Shmoolik

    2008-10-01

    Memory chips, now constituting a major part of semiconductor market, posit a special challenge for inspection, as they are generally produced with the smallest half-pitch available with today's technology. This is true, in particular, to photomasks of advanced memory devices, which are at the forefront of the "low-k1" regime. In this paper we present a novel photomask inspection approach, that is particularly suitable for low-k1 layers of advanced memory chips, owing to their typical dense and periodic structure. The method we present can produce a very strong signal for small mask defects, by suppression of the modulation of the pattern's image. Unlike dark-field detection, however, here a single diffraction order associated with the pattern generates a constant "gray" background image, that is used for signal enhancement. We define the theoretical basis for the new detection technique, and show, both analytically and numerically, that it can easily achieve a detection line past the printability spec, and that in cases it is at least as sensitive as high-resolution based detection. We also demonstrate this claim experimentally on a customer mask, using the platform of Applied Material's newly released Aera2TM mask inspection tool. The high sensitivity demonstrates the important and often overlooked concept that resolution is not synonymous with sensitivity. The novel detection method is advantageous in several other aspects, such as the very simple implementation, the high throughput, and the relatively simple pre- and post-processing algorithms required for signal extraction. These features, and in particular the very high sensitivity, make this novel detection method an attractive inspection option for advanced memory devices.

  1. Skeletal mechanism generation for surrogate fuels using directed relation graph with error propagation and sensitivity analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niemeyer, Kyle E.; Sung, Chih-Jen; Raju, Mandhapati P.

    2010-09-15

    A novel implementation for the skeletal reduction of large detailed reaction mechanisms using the directed relation graph with error propagation and sensitivity analysis (DRGEPSA) is developed and presented with examples for three hydrocarbon components, n-heptane, iso-octane, and n-decane, relevant to surrogate fuel development. DRGEPSA integrates two previously developed methods, directed relation graph-aided sensitivity analysis (DRGASA) and directed relation graph with error propagation (DRGEP), by first applying DRGEP to efficiently remove many unimportant species prior to sensitivity analysis to further remove unimportant species, producing an optimally small skeletal mechanism for a given error limit. It is illustrated that the combination ofmore » the DRGEP and DRGASA methods allows the DRGEPSA approach to overcome the weaknesses of each, specifically that DRGEP cannot identify all unimportant species and that DRGASA shields unimportant species from removal. Skeletal mechanisms for n-heptane and iso-octane generated using the DRGEP, DRGASA, and DRGEPSA methods are presented and compared to illustrate the improvement of DRGEPSA. From a detailed reaction mechanism for n-alkanes covering n-octane to n-hexadecane with 2115 species and 8157 reactions, two skeletal mechanisms for n-decane generated using DRGEPSA, one covering a comprehensive range of temperature, pressure, and equivalence ratio conditions for autoignition and the other limited to high temperatures, are presented and validated. The comprehensive skeletal mechanism consists of 202 species and 846 reactions and the high-temperature skeletal mechanism consists of 51 species and 256 reactions. Both mechanisms are further demonstrated to well reproduce the results of the detailed mechanism in perfectly-stirred reactor and laminar flame simulations over a wide range of conditions. The comprehensive and high-temperature n-decane skeletal mechanisms are included as supplementary material with this article. (author)« less

  2. High-Sensitivity Cardiac Troponin and the Risk Stratification of Patients With Renal Impairment Presenting With Suspected Acute Coronary Syndrome

    PubMed Central

    Miller-Hodges, Eve; Anand, Atul; Shah, Anoop S.V.; Chapman, Andrew R.; Gallacher, Peter; Lee, Kuan Ken; Farrah, Tariq; Halbesma, Nynke; Blackmur, James P.; Newby, David E.; Mills, Nicholas L.

    2018-01-01

    Background: High-sensitivity cardiac troponin testing may improve the risk stratification and diagnosis of myocardial infarction, but concentrations can be challenging to interpret in patients with renal impairment, and the effectiveness of testing in this group is uncertain. Methods: In a prospective multicenter study of consecutive patients with suspected acute coronary syndrome, we evaluated the performance of high-sensitivity cardiac troponin I in those with and without renal impairment (estimated glomerular filtration rate <60mL/min/1.73m2). The negative predictive value and sensitivity of troponin concentrations below the risk stratification threshold (5 ng/L) at presentation were reported for a primary outcome of index type 1 myocardial infarction, or type 1 myocardial infarction or cardiac death at 30 days. The positive predictive value and specificity at the 99th centile diagnostic threshold (16 ng/L in women, 34 ng/L in men) was determined for index type 1 myocardial infarction. Subsequent type 1 myocardial infarction and cardiac death were reported at 1 year. Results: Of 4726 patients identified, 904 (19%) had renal impairment. Troponin concentrations <5 ng/L at presentation identified 17% of patients with renal impairment as low risk for the primary outcome (negative predictive value, 98.4%; 95% confidence interval [CI], 96.0%–99.7%; sensitivity 98.9%; 95%CI, 97.5%–99.9%), in comparison with 56% without renal impairment (P<0.001) with similar performance (negative predictive value, 99.7%; 95% CI, 99.4%–99.9%; sensitivity 98.4%; 95% CI, 97.2%–99.4%). The positive predictive value and specificity at the 99th centile were lower in patients with renal impairment at 50.0% (95% CI, 45.2%–54.8%) and 70.9% (95% CI, 67.5%–74.2%), respectively, in comparison with 62.4% (95% CI, 58.8%–65.9%) and 92.1% (95% CI, 91.2%–93.0%) in those without. At 1 year, patients with troponin concentrations >99th centile and renal impairment were at greater risk of subsequent myocardial infarction or cardiac death than those with normal renal function (24% versus 10%; adjusted hazard ratio, 2.19; 95% CI, 1.54–3.11). Conclusions: In suspected acute coronary syndrome, high-sensitivity cardiac troponin identified fewer patients with renal impairment as low risk and more as high risk, but with lower specificity for type 1 myocardial infarction. Irrespective of diagnosis, patients with renal impairment and elevated cardiac troponin concentrations had a 2-fold greater risk of a major cardiac event than those with normal renal function, and should be considered for further investigation and treatment. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01852123. PMID:28978551

  3. Milagro Limits and HAWC Sensitivity for the Rate-Density of Evaporating Primordial Black Holes

    NASA Technical Reports Server (NTRS)

    Abdo, A. A.; Abeysekara, A. U.; Alfaro, R.; Allen, B.T.; Alvarez, C.; Alvarez, J. D.; Arceo, R.; Arteaga-Velazquez, J. C.; Aune, T.; Ayala Solares, H. A.; hide

    2014-01-01

    Primordial Black Holes (PBHs) are gravitationally collapsed objects that may have been created by density fluctuations in the early universe and could have arbitrarily small masses down to the Planck scale. Hawking showed that due to quantum effects, a black hole has a temperature inversely proportional to its mass and will emit all species of fundamental particles thermally. PBHs with initial masses of approximately 5.0 x 10 (sup 14) grams should be expiring in the present epoch with bursts of high-energy particles, including gamma radiation in the gigaelectronvolt - teraelectronvolt energy range. The Milagro high energy observatory, which operated from 2000 to 2008, is sensitive to the high end of the PBH evaporation gamma-ray spectrum. Due to its large field-of-view, more than 90 percent duty cycle and sensitivity up to 100 teraelectronvolt gamma rays, the Milagro observatory is well suited to perform a search for PBH bursts. Based on a search on the Milagro data, we report new PBH burst rate density upper limits over a range of PBH observation times. In addition, we report the sensitivity of the Milagro successor, the High Altitude Water Cherenkov (HAWC) observatory, to PBH evaporation events.

  4. A highly sensitive and specific capacitive aptasensor for rapid and label-free trace analysis of Bisphenol A (BPA) in canned foods.

    PubMed

    Mirzajani, Hadi; Cheng, Cheng; Wu, Jayne; Chen, Jiangang; Eda, Shigotoshi; Najafi Aghdam, Esmaeil; Badri Ghavifekr, Habib

    2017-03-15

    A rapid, highly sensitive, specific and low-cost capacitive affinity biosensor is presented here for label-free and single step detection of Bisphenol A (BPA). The sensor design allows rapid prototyping at low-cost using printed circuit board material by benchtop equipment. High sensitivity detection is achieved through the use of a BPA-specific aptamer as probe molecule and large electrodes to enhance AC-electroelectrothermal effect for long-range transport of BPA molecules toward electrode surface. Capacitive sensing technique is used to determine the bounded BPA level by measuring the sample/electrode interfacial capacitance of the sensor. The developed biosensor can detect BPA level in 20s and exhibits a large linear range from 1 fM to 10 pM, with a limit of detection (LOD) of 152.93 aM. This biosensor was applied to test BPA in canned food samples and could successfully recover the levels of spiked BPA. This sensor technology is demonstrated to be highly promising and reliable for rapid, sensitive and on-site monitoring of BPA in food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Milagro Limits and HAWC Sensitivity for the Rate-Density of Evaporating Primordial Black Holes

    NASA Technical Reports Server (NTRS)

    Abdo, A. A.; Abeysekara, A. U.; Alfaro, R.; Allen, B. T.; Alvarez, C.; Alvarez, J. D.; Arceo, R.; Arteaga-Velazquez, J. C.; Aune, T.; Ayala Solares, H. A.; hide

    2014-01-01

    Primordial Black Holes (PBHs) are gravitationally collapsed objects that may have been created by density fluctuations in the early universe and could have arbitrarily small masses down to the Planck scale. Hawking showed that due to quantum effects, a black hole has a temperature inversely proportional to its mass and will emit all species of fundamental particles thermally. PBHs with initial masses of approx.5.0 x 10(exp 14) g should be expiring in the present epoch with bursts of high-energy particles, including gamma radiation in the GeV-TeV energy range. The Milagro high energy observatory, which operated from 2000 to 2008, is sensitive to the high end of the PBH evaporation gamma-ray spectrum. Due to its large field-of-view, more than 90% duty cycle and sensitivity up to 100 TeV gamma rays, the Milagro observatory is well suited to perform a search for PBH bursts. Based on a search on the Milagro data, we report new PBH burst rate density upper limits over a range of PBH observation times. In addition, we report the sensitivity of the Milagro successor, the High Altitude Water Cherenkov (HAWC) observatory, to PBH evaporation events.

  6. Analyzing Single Giant Unilamellar Vesicles With a Slotline-Based RF Nanometer Sensor

    DOE PAGES

    Cui, Yan; Kenworthy, Anne K.; Edidin, Michael; ...

    2016-03-11

    Novel techniques that enable reagent free detection and analysis of single cells are of great interest for the development of biological and medical sciences, as well as point-of-care health service technologies. Highly sensitive and broadband RF sensors are promising candidates for such a technique. In this paper, we present a highly sensitive and tunable RF sensor, which is based on interference processes and built with a 100-nm slotline structure. The highly concentrated RF fields, up to ~ 1.76×10 7 V/m, enable strong interactions between giant unilamellar vesicles (GUVs) and fields for high-sensitivity operations. We also provide two modeling approaches tomore » extract cell dielectric properties from measured scattering parameters. GUVs of different molecular compositions are synthesized and analyzed with the RF sensor at ~ 2, ~ 2.5, and ~ 2.8 GHz with an initial |S 21| min of ~ -100 dB. Corresponding GUV dielectric properties are obtained. Finally, a one-dimensional scanning of single GUV is also demonstrated.« less

  7. Heterostructured TiO2/NiTiO3 Nanorod Arrays for Inorganic Sensitized Solar Cells with Significantly Enhanced Photovoltaic Performance and Stability.

    PubMed

    Li, Yue-Ying; Wang, Jian-Gan; Sun, Huan-Huan; Wei, Bingqing

    2018-04-11

    Organic dyes used in the conventional dye-sensitized solar cells (DSSCs) suffer from poor light stability and high cost. In this work, we demonstrate a new inorganic sensitized solar cell based on ordered one-dimensional semiconductor nanorod arrays of TiO 2 /NiTiO 3 (NTO) heterostructures prepared via a facile two-step hydrothermal approach. The semiconductor heterostructure arrays are highly desirable and promising for DSSCs because of their direct charge transport capability and slow charge recombination rate. The low-cost NTO inorganic semiconductor possesses an appropriate band gap that matches well with TiO 2 , which behaves like a "dye" to enable efficient light harvesting and fast electron-hole separation. The solar cells constructed by the ordered TiO 2 /NTO heterostructure photoanodes show a significantly improved power conversion efficiency, high fill factor, and more promising, outstanding life stability. The present work will open up an avenue to design heterostructured inorganics for high-performance solar cells.

  8. Highly Sensitive and Ultrastable Skin Sensors for Biopressure and Bioforce Measurements Based on Hierarchical Microstructures.

    PubMed

    Sun, Qi-Jun; Zhuang, Jiaqing; Venkatesh, Shishir; Zhou, Ye; Han, Su-Ting; Wu, Wei; Kong, Ka-Wai; Li, Wen-Jung; Chen, Xianfeng; Li, Robert K Y; Roy, Vellaisamy A L

    2018-01-31

    Piezoresistive microsensors are considered to be essential components of the future wearable electronic devices. However, the expensive cost, complex fabrication technology, poor stability, and low yield have limited their developments for practical applications. Here, we present a cost-effective, relatively simple, and high-yield fabrication approach to construct highly sensitive and ultrastable piezoresistive sensors using a bioinspired hierarchically structured graphite/polydimethylsiloxane composite as the active layer. In this fabrication, a commercially available sandpaper is employed as the mold to develop the hierarchical structure. Our devices exhibit fascinating performance including an ultrahigh sensitivity (64.3 kPa -1 ), fast response time (<8 ms), low limit of detection of 0.9 Pa, long-term durability (>100 000 cycles), and high ambient stability (>1 year). The applications of these devices in sensing radial artery pulses, acoustic vibrations, and human body motion are demonstrated, exhibiting their enormous potential use in real-time healthcare monitoring and robotic tactile sensing.

  9. New Uses for Sensitivity Analysis: How Different Movement Tasks Effect Limb Model Parameter Sensitivity

    NASA Technical Reports Server (NTRS)

    Winters, J. M.; Stark, L.

    1984-01-01

    Original results for a newly developed eight-order nonlinear limb antagonistic muscle model of elbow flexion and extension are presented. A wider variety of sensitivity analysis techniques are used and a systematic protocol is established that shows how the different methods can be used efficiently to complement one another for maximum insight into model sensitivity. It is explicitly shown how the sensitivity of output behaviors to model parameters is a function of the controller input sequence, i.e., of the movement task. When the task is changed (for instance, from an input sequence that results in the usual fast movement task to a slower movement that may also involve external loading, etc.) the set of parameters with high sensitivity will in general also change. Such task-specific use of sensitivity analysis techniques identifies the set of parameters most important for a given task, and even suggests task-specific model reduction possibilities.

  10. Assessing the sensitivity of bovine tuberculosis surveillance in Canada's cattle population, 2009-2013.

    PubMed

    El Allaki, Farouk; Harrington, Noel; Howden, Krista

    2016-11-01

    The objectives of this study were (1) to estimate the annual sensitivity of Canada's bTB surveillance system and its three system components (slaughter surveillance, export testing and disease investigation) using a scenario tree modelling approach, and (2) to identify key model parameters that influence the estimates of the surveillance system sensitivity (SSSe). To achieve these objectives, we designed stochastic scenario tree models for three surveillance system components included in the analysis. Demographic data, slaughter data, export testing data, and disease investigation data from 2009 to 2013 were extracted for input into the scenario trees. Sensitivity analysis was conducted to identify key influential parameters on SSSe estimates. The median annual SSSe estimates generated from the study were very high, ranging from 0.95 (95% probability interval [PI]: 0.88-0.98) to 0.97 (95% PI: 0.93-0.99). Median annual sensitivity estimates for the slaughter surveillance component ranged from 0.95 (95% PI: 0.88-0.98) to 0.97 (95% PI: 0.93-0.99). This shows that slaughter surveillance to be the major contributor to overall surveillance system sensitivity with a high probability to detect M. bovis infection if present at a prevalence of 0.00028% or greater during the study period. The export testing and disease investigation components had extremely low component sensitivity estimates-the maximum median sensitivity estimates were 0.02 (95% PI: 0.014-0.023) and 0.0061 (95% PI: 0.0056-0.0066) respectively. The three most influential input parameters on the model's output (SSSe) were the probability of a granuloma being detected at slaughter inspection, the probability of a granuloma being present in older animals (≥12 months of age), and the probability of a granuloma sample being submitted to the laboratory. Additional studies are required to reduce the levels of uncertainty and variability associated with these three parameters influencing the surveillance system sensitivity. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  11. High-field/high-pressure ESR

    NASA Astrophysics Data System (ADS)

    Sakurai, T.; Okubo, S.; Ohta, H.

    2017-07-01

    We present a historical review of high-pressure ESR systems with emphasis on our recent development of a high-pressure, high-field, multi-frequency ESR system. Until 2000, the X-band system was almost established using a resonator filled with dielectric materials or a combination of the anvil cell and dielectric resonators. Recent developments have shifted from that in the low-frequency region, such as X-band, to that in multi-frequency region. High-pressure, high-field, multi-frequency ESR systems are classified into two types. First are the systems that use a vector network analyzer or a quasi-optical bridge, which have high sensitivity but a limited frequency region; the second are like our system, which has a very broad frequency region covering the THz region, but lower sensitivity. We will demonstrate the usefulness of our high-pressure ESR system, in addition to its experimental limitations. We also discuss the recent progress of our system and future plans.

  12. Design and Characterization of a Novel Bio-inspired Hair Flow Sensor Based on Resonant Sensing

    NASA Astrophysics Data System (ADS)

    Guo, X.; Yang, B.; Wang, Q. H.; Lu, C. F.; Hu, D.

    2018-03-01

    Flow sensors inspired by the natural hair sensing mechanism have great prospect in the research of micro-autonomous system and technology (MAST) for the three-dimensional structure characteristics with high spatial and quality utilization. A novel bio-inspired hair flow sensor (BHFS) based on resonant sensing with a unique asymmetric design is presented in this paper. A hair transducer and a signal detector which is constituted of a two-stage micro-leverage mechanism and two symmetrical resonators (double ended tuning fork, DETF) are adopted to realize the high sensitivity to air flow. The sensitivity of the proposed BHFS is improved significantly than the published ones due to the high sensitivity of resonators and the higher amplification factor possessed by the two-stage micro-leverage mechanism. The standard deep dry silicon on glass (DDSOG) process is chosen to fabricate the proposed BHFS. The experiment result demonstrates that the fabricated BHFS has a mechanical sensitivity of 5.26 Hz/(m/s)2 at a resonant frequency of 22 kHz with the hair height of 6 mm.

  13. PSP Measurement of Stator Vane Surface Pressures in a High Speed Fan

    NASA Technical Reports Server (NTRS)

    Lepicovsky, Jan

    1998-01-01

    This paper presents measurements of static pressures on the stator vane suction side of a high-speed single stage fan using the technique of pressure sensitive paint (PSP). The paper illustrates development in application of the relatively new experimental technique to the complex environment of internal flows in turbomachines. First, there is a short explanation of the physics of the PSP technique and a discussion of calibration methods for pressure sensitive paint in the turbomachinery environment. A description of the image conversion process follows. The recorded image of the stator vane pressure field is skewed due to the limited optical access and must be converted to the meridional plane projection for comparison with analytical predictions. The experimental results for seven operating conditions along an off-design rotational speed line are shown in a concise form, including performance map points, mindspan static tap pressure distributions, and vane suction side pressure fields. Then, a comparison between static tap and pressure sensitive paint data is discussed. Finally, the paper lists shortcomings of the pressure sensitive paint technology and lessons learned in this high-speed fan application.

  14. Are amino groups advantageous to insensitive high explosives (IHEs)?

    PubMed

    Cao, Xia; Wen, Yushi; Xiang, Bin; Long, Xinping; Zhang, Chaoyang

    2012-10-01

    There is usually a contradiction between increasing energy densities and reducing sensitivities of explosives. The explosives with both high energy densities and low sensitivities, or the so-called insensitive high explosives (IHEs), are desirable in most cases. It seems from applied explosives that amino groups are advantageous to IHE but the amount of amino groups contained IHEs is very limited. To make this clear, we present systemic examinations of the effects on the two properties stressed in IHEs after introducing amino groups to different molecular skeletons. As a result, the amino groups on resonant sites to nitro groups in conjugated systems can improve distinctly sensitivities and change energy densities in terms of oxygen balance; while the amino groups in unconjugated systems can hardly increase energy densities and usually cause increased sensitivities. It agrees well with a fact that almost all the molecules of applied amino group contained explosives possess conjugated skeletons. We therefore confirm that if amino groups are introduced resonantly to a nitro group in a conjugated system and the introduction improves OB, they are advantageous to IHEs.

  15. Highly sensitive image-derived indices of water-stressed plants using hyperspectral imaging in SWIR and histogram analysis

    PubMed Central

    Kim, David M.; Zhang, Hairong; Zhou, Haiying; Du, Tommy; Wu, Qian; Mockler, Todd C.; Berezin, Mikhail Y.

    2015-01-01

    The optical signature of leaves is an important monitoring and predictive parameter for a variety of biotic and abiotic stresses, including drought. Such signatures derived from spectroscopic measurements provide vegetation indices – a quantitative method for assessing plant health. However, the commonly used metrics suffer from low sensitivity. Relatively small changes in water content in moderately stressed plants demand high-contrast imaging to distinguish affected plants. We present a new approach in deriving sensitive indices using hyperspectral imaging in a short-wave infrared range from 800 nm to 1600 nm. Our method, based on high spectral resolution (1.56 nm) instrumentation and image processing algorithms (quantitative histogram analysis), enables us to distinguish a moderate water stress equivalent of 20% relative water content (RWC). The identified image-derived indices 15XX nm/14XX nm (i.e. 1529 nm/1416 nm) were superior to common vegetation indices, such as WBI, MSI, and NDWI, with significantly better sensitivity, enabling early diagnostics of plant health. PMID:26531782

  16. Self-Activated Transparent All-Graphene Gas Sensor with Endurance to Humidity and Mechanical Bending.

    PubMed

    Kim, Yeon Hoo; Kim, Sang Jin; Kim, Yong-Jin; Shim, Yeong-Seok; Kim, Soo Young; Hong, Byung Hee; Jang, Ho Won

    2015-10-27

    Graphene is considered as one of leading candidates for gas sensor applications in the Internet of Things owing to its unique properties such as high sensitivity to gas adsorption, transparency, and flexibility. We present self-activated operation of all graphene gas sensors with high transparency and flexibility. The all-graphene gas sensors which consist of graphene for both sensor electrodes and active sensing area exhibit highly sensitive, selective, and reversible responses to NO2 without external heating. The sensors show reliable operation under high humidity conditions and bending strain. In addition to these remarkable device performances, the significantly facile fabrication process enlarges the potential of the all-graphene gas sensors for use in the Internet of Things and wearable electronics.

  17. Correlation of Radiological and Endoscopic Findings in Patients Presenting with Dysphagia.

    PubMed

    Sachdeva, Kavita; Kaul, Vineet

    2017-03-01

    Dysphagia is a common symptom with diverse etiology in otolaryngology. In the present study clinicopathological, radiological and endoscopic evaluation of patients was done in a tertiary care hospital in patients presenting with dysphagia. A prospective nonrandomized observational study was carried out on total of 80 cases having dysphagia during March 2015 to August 2016. In the present study, out of 80 patients, youngest case was a three years old child while oldest case was an 85 years old female. The mean age was 48.3 ± 20.3 years. The majority of cases were in age group 41-59 years (35%). Male to female ratio was 2.33:1. The mean duration of illness was 15.44 weeks. 15% of patients had absolute dysphagia. For detecting the lesion, Barium swallow study (BSS) showed a total sensitivity of 49.05% (n = 53), Computerised Tomography (CT) showed a total sensitivity of 85.70% (n = 49), plain skiagram neck & chest showed a total sensitivity of 88.88% (n = 9) and endoscopy was the most sensitive test overall as it showed a total sensitivity of 98.75% (n = 80). No complications were reported with either rigid or flexible endoscopy. Dysphagia is a common presenting complaint in otolaryngology with cases coming directly or being referred from other specialities. Males are more commonly affected than females and incidence of malignancy increases with age. Endoscopy can become the first screening test in dysphagia due to its high sensitivity and low risk of complications, with radiological tests being done in an adjunct manner.

  18. A Flexible and Highly Sensitive Pressure Sensor Based on a PDMS Foam Coated with Graphene Nanoplatelets

    PubMed Central

    Rinaldi, Andrea; Tamburrano, Alessio; Fortunato, Marco; Sarto, Maria Sabrina

    2016-01-01

    The demand for high performance multifunctional wearable devices is more and more pushing towards the development of novel low-cost, soft and flexible sensors with high sensitivity. In the present work, we describe the fabrication process and the properties of new polydimethylsiloxane (PDMS) foams loaded with multilayer graphene nanoplatelets (MLGs) for application as high sensitive piezoresistive pressure sensors. The effective DC conductivity of the produced foams is measured as a function of MLG loading. The piezoresistive response of the MLG-PDMS foam-based sensor at different strain rates is assessed through quasi-static pressure tests. The results of the experimental investigations demonstrated that sensor loaded with 0.96 wt.% of MLGs is characterized by a highly repeatable pressure-dependent conductance after a few stabilization cycles and it is suitable for detecting compressive stresses as low as 10 kPa, with a sensitivity of 0.23 kPa−1, corresponding to an applied pressure of 70 kPa. Moreover, it is estimated that the sensor is able to detect pressure variations of ~1 Pa. Therefore, the new graphene-PDMS composite foam is a lightweight cost-effective material, suitable for sensing applications in the subtle or low and medium pressure ranges. PMID:27999251

  19. An early warning system for high climate sensitivity? (Invited)

    NASA Astrophysics Data System (ADS)

    Pierrehumbert, R.

    2010-12-01

    The scientific case for the clear and present danger of global warming has been unassailable at least since the release of the Charney Report more than thirty years ago, if not longer. While prompt action to begin decarbonizing energy systems could still head off much of the potential warming, it is distinctly possible that emissions will continue unabated in the coming decades, leading to a doubling or more of pre-industrial carbon dioxide concentrations. At present, we are in the unenviable position of not even knowing how bad things will get if this scenario comes to pass, because of the uncertainty in climate sensitivity. If climate sensitivity is high, then the consequences will be dire, perhaps even catastrophic. As the world continues to warm in response to continued carbon dioxide emissions, will we at least be able to monitor the climate and provide an early warning that the planet is on a high-sensitivity track, if such turns out to be the case? At what point will we actually know the climate sensitivity? It has long been recognized that the prime contributor to uncertainty in climate sensitivity is uncertainty in cloud feedbacks. Study of paleoclimate and climate of the past century has not been able to resolve which models do cloud feedback most correctly, because of uncertainties in radiative forcing. In this talk, I will discuss monitoring requirements, and analysis techniques, that might have the potential to determine which climate models most faithfully represent climate feedbacks, and thus determine which models provide the best estimate of climate sensitivity. The endeavor is complicated by the distinction between transient climate response and equilibrium climate sensitivity. I will discuss the particular challenges posed by this issue, particularly in light of recent indications that the pattern of ocean heat storage may lead to different cloud feedbacks in the transient warming stage than apply once the system has reached equilibrium. Apart from this problem, the transient nature of climate response driven by increasing CO2 requires careful monitoring of ocean heat storage as well as top-of-atmosphere radiative budgets, if climate sensitivity is to be estimated. Water vapor feedback is not considered as uncertain as cloud feedback, but there is still a considerable potential for surprises. I will discuss microwave monitoring requirements for tracking water vapor feedback. At the other extreme, the longer term feedbacks that contribute to Earth System Sensitivity are even more uncertain than cloud feedbacks, particularly with regard to the terrestrial carbon cycle. Prospects for obtaining an early warning of a PETM-type organic carbon release seem bleak. Finally, I will discuss the particular challenge of obtaining an early warning of high climate sensitivity in the case that the climate system has a bifurcation.

  20. Mechanism behind Resistance against the Organophosphate Azamethiphos in Salmon Lice (Lepeophtheirus salmonis)

    PubMed Central

    Kaur, Kiranpreet; Helgesen, Kari Olli; Bakke, Marit Jørgensen; Horsberg, Tor Einar

    2015-01-01

    Acetylcholinesterase (AChE) is the primary target for organophosphates (OP). Several mutations have been reported in AChE to be associated with the reduced sensitivity against OP in various arthropods. However, to the best of our knowledge, no such reports are available for Lepeophtheirus salmonis. Hence, in the present study, we aimed to determine the association of AChE(s) gene(s) with resistance against OP. We screened the AChE genes (L. salmonis ace1a and ace1b) in two salmon lice populations: one sensitive (n=5) and the other resistant (n=5) for azamethiphos, a commonly used OP in salmon farming. The screening led to the identification of a missense mutation Phe362Tyr in L. salmonis ace1a, (corresponding to Phe331 in Torpedo californica AChE) in all the samples of the resistant population. We confirmed the potential role of the mutation, with reduced sensitivity against azamethiphos in L. salmonis, by screening for Phe362Tyr in 2 sensitive and 5 resistant strains. The significantly higher frequency of the mutant allele (362Tyr) in the resistant strains clearly indicated the possible association of Phe362Tyr mutation in L. salmonis ace1a with resistance towards azamethiphos. The 3D modelling, short term survival experiments and enzymatic assays further supported the imperative role of Phe362Tyr in reduced sensitivity of L. salmonis for azamethiphos. Based on all these observations, the present study, for the first time, presents the mechanism of resistance in L. salmonis against azamethiphos. In addition, we developed a rapid diagnostic tool for the high throughput screening of Phe362Tyr mutation using High Resolution Melt analysis. PMID:25893248

  1. Artificial neural networks: Predicting head CT findings in elderly patients presenting with minor head injury after a fall.

    PubMed

    Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L

    2017-02-01

    To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Aortic Baroreceptors Display Higher Mechanosensitivity than Carotid Baroreceptors.

    PubMed

    Lau, Eva On-Chai; Lo, Chun-Yin; Yao, Yifei; Mak, Arthur Fuk-Tat; Jiang, Liwen; Huang, Yu; Yao, Xiaoqiang

    2016-01-01

    Arterial baroreceptors are mechanical sensors that detect blood pressure changes. It has long been suggested that the two arterial baroreceptors, aortic and carotid baroreceptors, have different pressure sensitivities. However, there is no consensus as to which of the arterial baroreceptors are more sensitive to changes in blood pressure. In the present study, we employed independent methods to compare the pressure sensitivity of the two arterial baroreceptors. Firstly, pressure-activated action potential firing was measured by whole-cell current clamp with a high-speed pressure clamp system in primary cultured baroreceptor neurons. The results show that aortic depressor neurons possessed a higher percentage of mechano-sensitive neurons. Furthermore, aortic baroreceptor neurons show a lower pressure threshold than that of carotid baroreceptor neurons. Secondly, uniaxial stretching of baroreceptor neurons, that mimics the forces exerted on blood vessels, elicited a larger increase in intracellular Ca(2+) rise in aortic baroreceptor neurons than in carotid baroreceptor neurons. Thirdly, the pressure-induced action potential firing in the aortic depressor nerve recorded in vivo was also higher. The present study therefore provides for a basic physiological understanding on the pressure sensitivity of the two baroreceptor neurons and suggests that aortic baroreceptors have a higher pressure sensitivity than carotid baroreceptors.

  3. "Lollipop-shaped" high-sensitivity Microelectromechanical Systems vector hydrophone based on Parylene encapsulation

    NASA Astrophysics Data System (ADS)

    Liu, Yuan; Wang, Renxin; Zhang, Guojun; Du, Jin; Zhao, Long; Xue, Chenyang; Zhang, Wendong; Liu, Jun

    2015-07-01

    This paper presents methods of promoting the sensitivity of Microelectromechanical Systems (MEMS) vector hydrophone by increasing the sensing area of cilium and perfect insulative Parylene membrane. First, a low-density sphere is integrated with the cilium to compose a "lollipop shape," which can considerably increase the sensing area. A mathematic model on the sensitivity of the "lollipop-shaped" MEMS vector hydrophone is presented, and the influences of different structural parameters on the sensitivity are analyzed via simulation. Second, the MEMS vector hydrophone is encapsulated through the conformal deposition of insulative Parylene membrane, which enables underwater acoustic monitoring without any typed sound-transparent encapsulation. Finally, the characterization results demonstrate that the sensitivity reaches up to -183 dB (500 Hz 0dB at 1 V/ μPa ), which is increased by more than 10 dB, comparing with the previous cilium-shaped MEMS vector hydrophone. Besides, the frequency response takes on a sensitivity increment of 6 dB per octave. The working frequency band is 20-500 Hz and the concave point depth of 8-shaped directivity is beyond 30 dB, indicating that the hydrophone is promising in underwater acoustic application.

  4. Experiential avoidance as a moderator of the relationship between anxiety sensitivity and perceived stress.

    PubMed

    Bardeen, Joseph R; Fergus, Thomas A; Orcutt, Holly K

    2013-09-01

    Given the significant deleterious effects of stress on psychological and physical well-being, the present two-part study sought to clarify relations among putative vulnerability factors (i.e., anxiety sensitivity, experiential avoidance) for perceived stress. Relations among anxiety sensitivity, experiential avoidance, and perceived stress were examined using a large college student sample (N=400) in Study 1 and were replicated using a large community sample (N=838) in Study 2. As predicted, experiential avoidance moderated the relationship between anxiety sensitivity and perceived stress. Contrary to expectations, simple effects in both studies revealed that anxiety sensitivity shared a significant positive association with perceived stress at low, but not high, levels of experiential avoidance. The moderating role of experiential avoidance was found to be robust to the effects of general distress. Moreover, anxiety sensitivity and experiential avoidance evidenced a differential pattern of relations with perceived stress than was evidenced with related negative affective states (i.e., anxiety and depression). The present results suggest that experiential avoidance appears to be a vulnerability factor of particular importance for understanding the phenomenology of perceived stress. Conceptual and clinical implications are discussed. Copyright © 2013. Published by Elsevier Ltd.

  5. Ultrafast, sensitive and large-volume on-chip real-time PCR for the molecular diagnosis of bacterial and viral infections.

    PubMed

    Houssin, Timothée; Cramer, Jérémy; Grojsman, Rébecca; Bellahsene, Lyes; Colas, Guillaume; Moulet, Hélène; Minnella, Walter; Pannetier, Christophe; Leberre, Maël; Plecis, Adrien; Chen, Yong

    2016-04-21

    To control future infectious disease outbreaks, like the 2014 Ebola epidemic, it is necessary to develop ultrafast molecular assays enabling rapid and sensitive diagnoses. To that end, several ultrafast real-time PCR systems have been previously developed, but they present issues that hinder their wide adoption, notably regarding their sensitivity and detection volume. An ultrafast, sensitive and large-volume real-time PCR system based on microfluidic thermalization is presented herein. The method is based on the circulation of pre-heated liquids in a microfluidic chip that thermalize the PCR chamber by diffusion and ultrafast flow switches. The system can achieve up to 30 real-time PCR cycles in around 2 minutes, which makes it the fastest PCR thermalization system for regular sample volume to the best of our knowledge. After biochemical optimization, anthrax and Ebola simulating agents could be respectively detected by a real-time PCR in 7 minutes and a reverse transcription real-time PCR in 7.5 minutes. These detections are respectively 6.4 and 7.2 times faster than with an off-the-shelf apparatus, while conserving real-time PCR sample volume, efficiency, selectivity and sensitivity. The high-speed thermalization also enabled us to perform sharp melting curve analyses in only 20 s and to discriminate amplicons of different lengths by rapid real-time PCR. This real-time PCR microfluidic thermalization system is cost-effective, versatile and can be then further developed for point-of-care, multiplexed, ultrafast and highly sensitive molecular diagnoses of bacterial and viral diseases.

  6. Three Minute Method for Amino Acid Analysis by UHPLC and high resolution quadrupole orbitrap mass spectrometry

    PubMed Central

    Nemkov, Travis; D'Alessandro, Angelo; Hansen, Kirk C.

    2015-01-01

    Amino acid analysis is a powerful bioanalytical technique for many biomedical research endeavors, including cancer, emergency medicine, nutrition and neuroscience research. In the present study, we present a three minute analytical method for underivatized amino acid analysis that employs ultra-high performance liquid chromatography and high resolution quadrupole orbitrap mass spectrometry. This method has demonstrated linearity (mM to nM range), reproducibility (intra-day<5%, inter-day<20%), sensitivity (low fmol) and selectivity. Here, we illustrate the rapidity and accuracy of the method through comparison with conventional liquid chromatography-mass spectrometry methods. We further demonstrate the robustness and sensitivity of this method on a diverse range of biological matrices. Using this method we were able to selectively discriminate murine pancreatic cancer cells with and without knocked down expression of Hypoxia Inducible Factor 1α; plasma, lymph and bronchioalveolar lavage fluid samples from control versus hemorrhaged rats; and muscle tissue samples harvested from rats subjected to both low fat and high fat diets. Furthermore, we were able to exploit the sensitivity of the method to detect and quantify the release of glutamate from sparsely isolated murine taste buds. Spiked in light or heavy standards (13C6-arginine, 13C6-lysine, 13C515N2-glutamine) or xenometabolites were used to determine coefficient of variations, confirm linearity of relative quantitation in four different matrices, and overcome matrix effects for absolute quantitation. The presented method enables high-throughput analysis of low abundance samples requiring only one percent of the material extracted from 100,000 cells, 10 μl of biological fluid, or 2 mg of muscle tissue. PMID:26058356

  7. Diagnostic Accuracy of a New High-Sensitivity Troponin I Assay and Five Accelerated Diagnostic Pathways for Ruling Out Acute Myocardial Infarction and Acute Coronary Syndrome.

    PubMed

    Greenslade, Jaimi H; Carlton, Edward W; Van Hise, Christopher; Cho, Elizabeth; Hawkins, Tracey; Parsonage, William A; Tate, Jillian; Ungerer, Jacobus; Cullen, Louise

    2018-04-01

    This diagnostic accuracy study describes the performance of 5 accelerated chest pain pathways, calculated with the new Beckman's Access high-sensitivity troponin I assay. High-sensitivity troponin I was measured with presentation and 2-hour blood samples in 1,811 patients who presented to an emergency department (ED) in Australia. Patients were classified as being at low risk according to 5 rules: modified accelerated diagnostic protocol to assess patients with chest pain symptoms using troponin as the only biomarker (m-ADAPT), the Emergency Department Assessment of Chest Pain Score (EDACS) pathway, the History, ECG, Age, Risk Factors, and Troponin (HEART) pathway, the No Objective Testing Rule, and the new Vancouver Chest Pain Rule. Endpoints were 30-day acute myocardial infarction and acute coronary syndrome. Measures of diagnostic accuracy for each rule were calculated. Data included 96 patients (5.3%) with acute myocardial infarction and 139 (7.7%) with acute coronary syndrome. The new Vancouver Chest Pain Rule and No Objective Testing Rule had high sensitivity for acute myocardial infarction (100%; 95% confidence interval [CI] 96.2% to 100% for both) and acute coronary syndrome (98.6% [95% CI 94.9% to 99.8%] and 99.3% [95% CI 96.1% to 100%]). The m-ADAPT, EDACS, and HEART pathways also yielded high sensitivity for acute myocardial infarction (96.9% [95% CI 91.1% to 99.4%] for m-ADAPT and 97.9% [95% CI 92.7% to 99.7%] for EDACS and HEART), but lower sensitivity for acute coronary syndrome (≤95.0% for all). The m-ADAPT, EDACS, and HEART rules classified more patients as being at low risk (64.3%, 62.5%, and 49.8%, respectively) than the new Vancouver Chest Pain Rule and No Objective Testing Rule (28.2% and 34.5%, respectively). In this cohort with a low prevalence of acute myocardial infarction and acute coronary syndrome, using the Beckman's Access high-sensitivity troponin I assay with the new Vancouver Chest Pain Rule or No Objective Testing Rule enabled approximately one third of patients to be safely discharged after 2-hour risk stratification with no further testing. The EDACS, m-ADAPT, or HEART pathway enabled half of ED patients to be rapidly referred for objective testing. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  8. MDS1, a dosage suppressor of an mck1 mutant, encodes a putative yeast homolog of glycogen synthase kinase 3.

    PubMed Central

    Puziss, J W; Hardy, T A; Johnson, R B; Roach, P J; Hieter, P

    1994-01-01

    The yeast gene MCK1 encodes a serine/threonine protein kinase that is thought to function in regulating kinetochore activity and entry into meiosis. Disruption of MCK1 confers a cold-sensitive phenotype, a temperature-sensitive phenotype, and sensitivity to the microtubule-destabilizing drug benomyl and leads to loss of chromosomes during growth on benomyl. A dosage suppression selection was used to identify genes that, when present at high copy number, could suppress the cold-sensitive phenotype of mck1::HIS3 mutant cells. Several unique classes of clones were identified, and one of these, designated MDS1, has been characterized in some detail. Nucleotide sequence data reveal that MDS1 encodes a serine/threonine protein kinase that is highly homologous to the shaggy/zw3 kinase in Drosophila melanogaster and its functional homolog, glycogen synthase kinase 3, in rats. The presence of MDS1 in high copy number rescues both the cold-sensitive and the temperature-sensitive phenotypes, but not the benomyl-sensitive phenotype, associated with the disruption of MCK1. Analysis of strains harboring an mds1 null mutation demonstrates that MDS1 is not essential during normal vegetative growth but appears to be required for meiosis. Finally, in vitro experiments indicate that the proteins encoded by both MCK1 and MDS1 possess protein kinase activity with substrate specificity similar to that of mammalian glycogen synthase kinase 3. Images PMID:8264650

  9. Ultrasensitive Detection of Single-Walled Carbon Nanotubes Using Surface Plasmon Resonance.

    PubMed

    Jang, Daeho; Na, Wonhwi; Kang, Minwook; Kim, Namjoon; Shin, Sehyun

    2016-01-05

    Because single-walled carbon nanotubes (SWNTs) are known to be a potentially dangerous material, inducing cancers and other diseases, any possible leakage of SWNTs through an aquatic medium such as drinking water will result in a major public threat. To solve this problem, for the present study, a highly sensitive, quantitative detection method of SWNTs in an aqueous solution was developed using surface plasmon resonance (SPR) spectroscopy. For a highly sensitive and specific detection, a strong affinity conjugation with biotin-streptavidin was adopted on an SPR sensing mechanism. During the pretreatment process, the SWNT surface was functionalized and hydrophilized using a thymine-chain based biotinylated single-strand DNA linker (B-ssDNA) and bovine serum albumin (BSA). The pretreated SWNTs were captured on a sensing film, the surface of which was immobilized with streptavidin on biotinylated gold film. The captured SWNTs were measured in real-time using SPR spectroscopy. Specific binding with SWNTs was verified through several validation experiments. The present method using an SPR sensor is capable of detecting SWNTs of as low as 100 fg/mL, which is the lowest level reported thus far for carbon-nanotube detection. In addition, the SPR sensor showed a linear characteristic within the range of 100 pg/mL to 200 ng/mL. These findings imply that the present SPR sensing method can detect an extremely low level of SWNTs in an aquatic environment with high sensitivity and high specificity, and thus any potential leakage of SWNTs into an aquatic environment can be precisely monitored within a couple of hours.

  10. Search for Indirect Signals of Dark Matter with The High Altitude Water Cherenkov (HAWC) Observatory

    NASA Astrophysics Data System (ADS)

    Baughman, Brian; Harding, Patrick; HAWC Collaboration

    2015-04-01

    The High Altitude Water Cherenkov (HAWC) observatory is a wide field-of-view observatory sensitive to 100 GeV-100 TeV gamma rays and cosmic rays. Located at an elevation of 4100 m on the Sierra Negra volcano in Mexico, HAWC observes extensive air showers from gamma rays via their production of Cherenkov light within an array of water tanks. With a wide field-of-view observing 2/3 of the sky each day and a sensitivity of greater than 1 Crab per day, HAWC has the ability to probe a large fraction of the sky for the signals of TeV-mass dark matter. HAWC's sensitivity to dark matter for several astrophysical sources and some early limits from the built detector will be presented.

  11. Quantum-dot-sensitized solar cells.

    PubMed

    Rühle, Sven; Shalom, Menny; Zaban, Arie

    2010-08-02

    Quantum-dot-sensitized solar cells (QDSCs) are a promising low-cost alternative to existing photovoltaic technologies such as crystalline silicon and thin inorganic films. The absorption spectrum of quantum dots (QDs) can be tailored by controlling their size, and QDs can be produced by low-cost methods. Nanostructures such as mesoporous films, nanorods, nanowires, nanotubes and nanosheets with high microscopic surface area, redox electrolytes and solid-state hole conductors are borrowed from standard dye-sensitized solar cells (DSCs) to fabricate electron conductor/QD monolayer/hole conductor junctions with high optical absorbance. Herein we focus on recent developments in the field of mono- and polydisperse QDSCs. Stability issues are adressed, coating methods are presented, performance is reviewed and special emphasis is given to the importance of energy-level alignment to increase the light to electric power conversion efficiency.

  12. Influence of skin cold sensation threshold in the occurrence of dental sensitivity during dental bleaching: a placebo controlled clinical trial.

    PubMed

    Rahal, Vanessa; Gallinari, Marjorie de Oliveira; Barbosa, Juliana Stuginski; Martins-Junior, Reynaldo Leite; Santos, Paulo Henrique Dos; Cintra, Luciano Tavares Angelo; Briso, André Luiz Fraga

    2018-01-18

    This study verified the occurrence of dental sensitivity in patients submitted to a 35% hydrogen peroxide based product (Whiteness HP Maxx 35% - FGM), skin cold sensation threshold (SCST) and its influence on dental sensitivity. Sixty volunteers were divided into 4 groups (n = 15), according to SCST (low: GI and GIII, and high: GII and IV) and bleaching treatment (hydrogen peroxide: GI and GII, and placebo: GIII and GIV). SCST was determined in the inner forearm for 6 different times using a neurosensory analyzer, the TSA II (Medoc Advanced Medical Systems, Ramat Yishai, Northern District, Israel). Dental sensitivity measurements were performed 10 different times using a thermal stimulus and an intraoral device attached to TSA II, positioned in the buccal surface of the upper right central incisor. Spontaneous dental sensitivity was also determined using the Visual Analogue Scale (VAS). Data were submitted to Student's t-test and Pearson's Correlation Test (α=0.05). SCST remained the same during bleaching treatment. Distinct responses of dental sensitivity were found in patients with low and high SCST during the first and third bleaching session (p≤0.05). The teeth submitted to the bleaching treatment became more sensitive to cold than those treated with placebo. Moreover, data obtained with TSA and VAS presented moderate correlation. Bleaching treatment increased dental sensitivity and skin cold sensation threshold might represent a determining factor in this occurrence, since low and high SCST patients had different responses to the thermal stimulus in the teeth.

  13. Relative sensitivity of an amphipod Hyalella azteca, a midge Chironomus dilutus, and a unionid mussel Lampsilis siliquoidea to a toxic sediment

    USGS Publications Warehouse

    Ingersoll, Christopher G.; Kunz, James L.; Hughes, Jamie P.; Wang, Ning; Ireland, D. Scott; Mount, David R.; Hockett, J. Russell; Valenti, Ted W

    2015-01-01

    The objective of the present study was to evaluate the relative sensitivity of test organisms in exposures to dilutions of a highly toxic sediment contaminated with metals and organic compounds. One dilution series was prepared using control sand (low total organic carbon [TOC; <0.1%, low binding capacity for contaminants]) and a second dilution series was prepared using control sediment from West Bearskin Lake, Minnesota, USA (high TOC [∼10% TOC, higher binding capacity for contaminants]). Test organisms included an amphipod (Hyalella azteca; 10-d and 28-d exposures), a midge (Chironomus dilutus; 20-d and 48-d exposures started with <1-h-old larvae, and 13-d and 48-d exposures started with 7-d-old larvae), and a unionid mussel (Lampsilis siliquoidea; 28-d exposures). Relative species sensitivity depended on the toxicity endpoint and the diluent. All 3 species were more sensitive in sand dilutions than in West Bearskin Lake sediment dilutions. The <1-h-old C. dilutus were more sensitive than 7-d-old C. dilutus, but replicate variability was high in exposures started with the younger midge larvae. Larval biomass and adult emergence endpoints of C. dilutus exhibited a similar sensitivity. Survival, weight, and biomass of H. azteca were more sensitive endpoints in 28-d exposures than in 10-d exposures. Weight and biomass of L. siliquoidea were sensitive endpoints in both sand and West Bearskin Lake sediment dilutions. Metals, ammonia, oil, and other organic contaminants may have contributed to the observed toxicity.

  14. U-bent plastic optical fiber based plasmonic biosensor for nucleic acid detection

    NASA Astrophysics Data System (ADS)

    Gowri, A.; Sai, V. V. R.

    2017-05-01

    This study presents the development of low cost, rapid and highly sensitive plasmonic sandwich DNA biosensor using U-bent plastic optical fiber (POF) probes with high evanescent wave absorbance sensitivity and gold nanoparticles (AuNP) as labels. Plastic optical fiber (PMMA core and fluorinated polymer as cladding) offer ease in machinability and handling due to which optimum U-bent geometry (with fiber and bend diameter of 0.5 and 1.5 mm respectively) for high sensitivity could be achieved. A sensitive fiber optic DNA biosensor is realized by (i) modifying the PMMA surface using ethylenediamine (EDA) in order to maximize the immobilization of capture oligonucleotides (ONs) and (ii) conjugating probe ONs to AuNP labels of optimum size ( 35 nm) with high extinction coefficient and optimal ON surface density. The sandwich hybridization assay on U-bent POF probes results in increase in optical absorbance through the probe with increase in target ON concentration due to the presence of increased number of AuNPs. The absorbance of light passing through the U-bent probe due to the presence of AuNP labels on its surface as result of sandwich DNA hybridization is measured using a halogen lamp and a fiber optic spectrometer. A picomolar limit of detection of target ON (0.2 pM or 1 pg/ml or 5 attomol in 25 μL) is achieved with this biosensing scheme, indicating its potential for the development of a highly sensitive DNA biosensor.

  15. Combining Monte Carlo methods with coherent wave optics for the simulation of phase-sensitive X-ray imaging

    PubMed Central

    Peter, Silvia; Modregger, Peter; Fix, Michael K.; Volken, Werner; Frei, Daniel; Manser, Peter; Stampanoni, Marco

    2014-01-01

    Phase-sensitive X-ray imaging shows a high sensitivity towards electron density variations, making it well suited for imaging of soft tissue matter. However, there are still open questions about the details of the image formation process. Here, a framework for numerical simulations of phase-sensitive X-ray imaging is presented, which takes both particle- and wave-like properties of X-rays into consideration. A split approach is presented where we combine a Monte Carlo method (MC) based sample part with a wave optics simulation based propagation part, leading to a framework that takes both particle- and wave-like properties into account. The framework can be adapted to different phase-sensitive imaging methods and has been validated through comparisons with experiments for grating interferometry and propagation-based imaging. The validation of the framework shows that the combination of wave optics and MC has been successfully implemented and yields good agreement between measurements and simulations. This demonstrates that the physical processes relevant for developing a deeper understanding of scattering in the context of phase-sensitive imaging are modelled in a sufficiently accurate manner. The framework can be used for the simulation of phase-sensitive X-ray imaging, for instance for the simulation of grating interferometry or propagation-based imaging. PMID:24763652

  16. Frequency behavior of the residual current devices

    NASA Astrophysics Data System (ADS)

    Erdei, Z.; Horgos, M.; Lung, C.; Pop-Vadean, A.; Muresan, R.

    2017-01-01

    This paper presents an experimental investigation into the operating characteristic of residual current devices when in presence of a residual current at a frequency of 60Hz. In order to protect persons and equipment effectively the residual current devices are made to be very sensitive to the ground fault current or the touch current. Because of their high sensitivity the residual current circuit breakers are prone to tripping under no-fault conditions.

  17. The Advanced Gamma-ray Imaging System (AGIS): Simulation Studies

    NASA Astrophysics Data System (ADS)

    Fegan, Stephen; Buckley, J. H.; Bugaev, S.; Funk, S.; Konopelko, A.; Maier, G.; Vassiliev, V. V.; Simulation Studies Working Group; AGIS Collaboration

    2008-03-01

    The Advanced Gamma-ray Imaging System (AGIS) is a concept for the next generation instrument in ground-based very high energy gamma-ray astronomy. It has the goal of achieving significant improvement in sensitivity over current experiments. We present the results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance, collecting area, angular resolution, background rejection, and sensitivity are discussed.

  18. Meat authentication: a new HPLC-MS/MS based method for the fast and sensitive detection of horse and pork in highly processed food.

    PubMed

    von Bargen, Christoph; Brockmeyer, Jens; Humpf, Hans-Ulrich

    2014-10-01

    Fraudulent blending of food products with meat from undeclared species is a problem on a global scale, as exemplified by the European horse meat scandal in 2013. Routinely used methods such as ELISA and PCR can suffer from limited sensitivity or specificity when processed food samples are analyzed. In this study, we have developed an optimized method for the detection of horse and pork in different processed food matrices using MRM and MRM(3) detection of species-specific tryptic marker peptides. Identified marker peptides were sufficiently stable to resist thermal processing of different meat products and thus allow the sensitive and specific detection of pork or horse in processed food down to 0.24% in a beef matrix system. In addition, we were able to establish a rapid 2-min extraction protocol for the efficient protein extraction from processed food using high molar urea and thiourea buffers. Together, we present here the specific and sensitive detection of horse and pork meat in different processed food matrices using MRM-based detection of marker peptides. Notably, prefractionation of proteins using 2D-PAGE or off-gel fractionation is not necessary. The presented method is therefore easily applicable in analytical routine laboratories without dedicated proteomics background.

  19. Molecular beacon-based real-time PCR method for detection of porcine DNA in gelatin and gelatin capsules.

    PubMed

    Mohamad, Nurhidayatul Asma; Mustafa, Shuhaimi; Khairil Mokhtar, Nur Fadhilah; El Sheikha, Aly Farag

    2018-03-05

    The pharmaceutical industry has boosted gelatin consumption worldwide. This is supported by the availability of cost-effective gelatin production from porcine by-products. However, cross-contamination of gelatin materials, where porcine gelatin was unintentionally included in the other animal sources of gelatin, has caused significant concerns about halal authenticity. The real-time polymerase chain reaction (PCR) has enabled a highly specific and sensitive animal species detection method in various food products. Hence, such a technique was employed in the present study to detect and quantify porcine DNA in gelatin using a molecular beacon probe, with differences in performance between mitochondrial (cytochrome b gene) and chromosomal DNA-(MPRE42 repetitive element) based porcine-specific PCR assays being compared. A higher sensitivity was observed in chromosomal DNA (MPRE-PCR assay), where this assay allows the detection of gelatin DNA at amounts as as low as 1 pg, whereas mitochondrial DNA (CBH-PCR assay) can only detect at levels down to 10 pg of gelatin DNA. When an analysis with commercial gelatin and gelatin capsule samples was conducted, the same result was observed, with a significantly more sensitive detection being provided by the repetitive element of chromosomal DNA. The present study has established highly sensitive DNA-based porcine detection systems derived from chromosomal DNA that are feasible for highly processed products such as gelatin and gelatin capsules containing a minute amount of DNA. This sensitive detection method can also be implemented to assist the halal authentication process of various food products available on the market. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  20. Increased Sensitivity to Angiotensin II is Present Postpartum in Women with History of Hypertensive Pregnancy

    PubMed Central

    Saxena, Aditi R.; Karumanchi, S. Ananth; Brown, Nancy J.; Royle, Caroline M.; McElrath, Thomas F.; Seely, Ellen W.

    2010-01-01

    Pregnancies complicated by new onset hypertension are associated with increased sensitivity to angiotensin II, but it is unclear if this sensitivity persists postpartum. We studied pressor response to infused angiotensin II in 25 normotensive postpartum women in both high and low sodium balance. Ten women had history of hypertensive pregnancy (five with preeclampsia; five with transient hypertension of pregnancy) and 15 women had history of uncomplicated, normotensive pregnancy. Systolic and diastolic blood pressures, aldosterone and soluble fms-like tyrosine kinase 1 (sFlt-1) levels were measured before and after angiotensin II infusion in both dietary phases. In high sodium balance, women with history of hypertensive pregnancy were normotensive but had significantly higher systolic and diastolic blood pressures than controls (115 vs. 104 mmHg and 73 vs. 65 mmHg, respectively, p<0.05). Women with history of hypertensive pregnancy had pressor response to salt loading, demonstrated by increase in systolic blood pressure on high salt diet. They also had greater systolic pressor response (10 vs. 2 mmHg, p=0.03), greater increase in aldosterone (56.8 vs. 30.8 ng/dL, p=0.03) and increase in sFlt-1 levels (11.0 vs. -18.9 pg/mL, p=0.02) after infusion of angiotensin II in low sodium balance, compared with controls. Thus, women with history of hypertensive pregnancy demonstrated salt sensitivity of blood pressure and had increased pressor, adrenal and sFlt-1 responses to infused angiotensin II in low sodium balance. Increased sensitivity to angiotensin II observed during pregnancy in women with hypertensive pregnancy is present postpartum; this feature may contribute to future cardiovascular risk in these women. PMID:20308605

  1. Increased sensitivity to angiotensin II is present postpartum in women with a history of hypertensive pregnancy.

    PubMed

    Saxena, Aditi R; Karumanchi, S Ananth; Brown, Nancy J; Royle, Caroline M; McElrath, Thomas F; Seely, Ellen W

    2010-05-01

    Pregnancies complicated by new-onset hypertension are associated with increased sensitivity to angiotensin II, but it is unclear whether this sensitivity persists postpartum. We studied pressor response to infused angiotensin II in 25 normotensive postpartum women in both high- and low-sodium balance. Ten women had a history of hypertensive pregnancy (5 with preeclampsia; 5 with transient hypertension of pregnancy), and 15 women had a history of uncomplicated, normotensive pregnancy. Systolic and diastolic blood pressures, aldosterone, and soluble fms-like tyrosine kinase 1 levels were measured before and after angiotensin II infusion in both dietary phases. In high sodium balance, women with a history of hypertensive pregnancy were normotensive but had significantly higher systolic and diastolic blood pressures than controls (115 versus 104 mm Hg and 73 versus 65 mm Hg, respectively; P<0.05). Women with a history of hypertensive pregnancy had a pressor response to salt loading, demonstrated by an increase in systolic blood pressure on a high-salt diet. They also had greater systolic pressor response (10 versus 2 mm Hg; P=0.03), greater increase in aldosterone (56.8 versus 30.8 ng/dL; P=0.03), and increase in soluble fms-like tyrosine kinase 1 levels (11.0 versus -18.9 pg/mL; P=0.02) after infusion of angiotensin II in low-sodium balance compared with controls. Thus, women with a history of hypertensive pregnancy demonstrated salt sensitivity of blood pressure and had increased pressor, adrenal, and soluble fms-like tyrosine kinase 1 responses to infused angiotensin II in low-sodium balance. Increased sensitivity to angiotensin II observed during pregnancy in women with hypertensive pregnancy is present postpartum; this feature may contribute to future cardiovascular risk in these women.

  2. On the measurement of turbulent fluctuations in high-speed flows using hot wires and hot films

    NASA Technical Reports Server (NTRS)

    Acharya, M.

    1978-01-01

    A hot wire has a limited life in high speed wind-tunnel flows because it is typically subjected to large dynamic loads. As a consequence hot films and modified hot wires are frequently used for turbulence measurements in such flows. However, the fluctuation sensitivities of such probes are reduced because of various factors, leading to erroneous results. This paper describes the results of tests on some sensors in both subsonic and supersonic boundary-layer flows. A simple technique to determine dynamic calibration correction factors for the sensitivities is also presented.

  3. All-fiber, long-active-length Fabry-Perot strain sensor.

    PubMed

    Pevec, Simon; Donlagic, Denis

    2011-08-01

    This paper presents a high-sensitivity, all-silica, all-fiber Fabry-Perot strain-sensor. The proposed sensor provides a long active length, arbitrary length of Fabry-Perot cavity, and low intrinsic temperature sensitivity. The sensor was micro-machined from purposely-developed sensor-forming fiber that is etched and directly spliced to the lead-in fiber. This manufacturing process has good potential for cost-effective, high-volume production. Its measurement range of over 3000 µε, and strain-resolution better than 1 µε were demonstrated by the application of a commercial, multimode fiber-based signal processor.

  4. 3-d brownian motion simulator for high-sensitivity nanobiotechnological applications.

    PubMed

    Toth, Arpád; Banky, Dániel; Grolmusz, Vince

    2011-12-01

    A wide variety of nanobiotechnologic applications are being developed for nanoparticle based in vitro diagnostic and imaging systems. Some of these systems make possible highly sensitive detection of molecular biomarkers. Frequently, the very low concentration of the biomarkers makes impossible the classical, partial differential equation-based mathematical simulation of the motion of the nanoparticles involved. We present a three-dimensional Brownian motion simulation tool for the prediction of the movement of nanoparticles in various thermal, viscosity, and geometric settings in a rectangular cuvette. For nonprofit users the server is freely available at the site http://brownian.pitgroup.org.

  5. Developments in Scanning Hall Probe Microscopy

    NASA Astrophysics Data System (ADS)

    Chouinard, Taras; Chu, Ricky; David, Nigel; Broun, David

    2009-05-01

    Low temperature scanning Hall probe microscopy is a sensitive means of imaging magnetic structures with high spatial resolution and magnetic flux sensitivity approaching that of a Superconducting Quantum Interference Device. We have developed a scanning Hall probe microscope with novel features, including highly reliable coarse positioning, in situ optimization of sensor-sample alignment and capacitive transducers for linear, long range positioning measurement. This has been motivated by the need to reposition accurately above fabricated nanostructures such as small superconducting rings. Details of the design and performance will be presented as well as recent progress towards time-resolved measurements with sub nanosecond resolution.

  6. High-speed asynchronous optical sampling for high-sensitivity detection of coherent phonons

    NASA Astrophysics Data System (ADS)

    Dekorsy, T.; Taubert, R.; Hudert, F.; Schrenk, G.; Bartels, A.; Cerna, R.; Kotaidis, V.; Plech, A.; Köhler, K.; Schmitz, J.; Wagner, J.

    2007-12-01

    A new optical pump-probe technique is implemented for the investigation of coherent acoustic phonon dynamics in the GHz to THz frequency range which is based on two asynchronously linked femtosecond lasers. Asynchronous optical sampling (ASOPS) provides the performance of on all-optical oscilloscope and allows us to record optically induced lattice dynamics over nanosecond times with femtosecond resolution at scan rates of 10 kHz without any moving part in the set-up. Within 1 minute of data acquisition time signal-to-noise ratios better than 107 are achieved. We present examples of the high-sensitivity detection of coherent phonons in superlattices and of the coherent acoustic vibration of metallic nanoparticles.

  7. Dopamine fluorescent sensors based on polypyrrole/graphene quantum dots core/shell hybrids.

    PubMed

    Zhou, Xi; Ma, Peipei; Wang, Anqi; Yu, Chenfei; Qian, Tao; Wu, Shishan; Shen, Jian

    2015-02-15

    A facilely prepared fluorescent sensor was developed for dopamine (DA) detection with high sensitivity and selectivity based on polypyrrole/graphene quantum dots (PPy/GQDs) core/shell hybrids. The composites exhibit strong fluorescence emission, which is dramatically enhanced as high as three times than pristine GQDs. The prepared sensor allows a highly sensitive determination of DA by fluorescent intensity decreasing with the addition of DA and presents a good linearity in range of 5-8000 nM with the detection limit of 10 pM (S/N = 3). Furthermore, the application of the proposed approach have been demonstrated in real samples and showed promise in diagnostic purposes. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Multimodal instrument for high-sensitivity autofluorescence and spectral optical coherence tomography of the human eye fundus

    PubMed Central

    Komar, Katarzyna; Stremplewski, Patrycjusz; Motoczyńska, Marta; Szkulmowski, Maciej; Wojtkowski, Maciej

    2013-01-01

    In this paper we present a multimodal device for imaging fundus of human eye in vivo which combines functionality of autofluorescence by confocal SLO with Fourier domain OCT. Native fluorescence of human fundus was excited by modulated laser beam (λ = 473 nm, 20 MHz) and lock-in detection was applied resulting in improving sensitivity. The setup allows for acquisition of high resolution OCT and high contrast AF images using fluorescence excitation power of 50-65 μW without averaging consecutive images. Successful functioning of constructed device have been demonstrated for 8 healthy volunteers of different age ranging from 24 to 83 years old. PMID:24298426

  9. GaAs-based resonant tunneling diode (RTD) epitaxy on Si for highly sensitive strain gauge applications

    PubMed Central

    2013-01-01

    As a highly sensitive strain gauge element, GaAs-based resonant tunneling diode (RTD) has already been applied in microelectromechanical system (MEMS) sensors. Due to poor mechanical properties and high cost, GaAs-based material has been limited in applications as the substrate for MEMS. In this work, we present a method to fabricate the GaAs-based RTD on Si substrate. From the experimental results, it can be concluded that the piezoresistive coefficient achieved with this method reached 3.42 × 10−9 m2/N, which is about an order of magnitude higher than the Si-based semiconductor piezoresistors. PMID:23651496

  10. Visual Neuroscience: A Retinal Ganglion Cell to Report Image Focus?

    PubMed

    Baden, Tom; Schaeffel, Frank; Berens, Philipp

    2017-02-20

    A recent study describes a mouse neuron projecting from the retina to the brain that exhibits exquisitely high sensitivity to high spatial frequency patterns presented over an unusually large receptive field: could this cell be a (de)focus detector? Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Model Program: Southern Lehigh High School, Center Valley, PA

    ERIC Educational Resources Information Center

    Colelli, Richard

    2009-01-01

    In this article, the author describes the technology education program at Southern Lehigh High School, Center Valley, Pennsylvania. The school district is presently providing an educational program known for its excellence and forward-looking perspective, which is sensitive to the changing needs of its students. Within the technology education…

  12. Nosema ceranae detection by microscopy and antibody tests

    USDA-ARS?s Scientific Manuscript database

    N. ceranae is now present in a high proportion of American honey bee hives. It has been implicated in colony mortality, especially in conjunction with parasites and other pathogens. PCR is the method of choice to detect light infections and to distinguish between species. It is highly sensitive a...

  13. HIGHLY SENSITIVE DIOXIN IMMUNOASSAY AND ITS APPLICATIONS TO SOIL AND BIOTA SAMPLES. (R825433)

    EPA Science Inventory

    Tetrachlorodibenzo-p-dioxin (TCDD) is a well-known highly toxic compound that is present in nearly all components of the global ecosystem, including air, soil, sediment, fish and humans. Dioxin analysis is equipment intensive and expensive requiring low ppt or even ppq ...

  14. Nuclear-Spin Gyroscope Based on an Atomic Co-Magnetometer

    NASA Technical Reports Server (NTRS)

    Romalis, Michael; Komack, Tom; Ghost, Rajat

    2008-01-01

    An experimental nuclear-spin gyroscope is based on an alkali-metal/noblegas co-magnetometer, which automatically cancels the effects of magnetic fields. Whereas the performances of prior nuclear-spin gyroscopes are limited by sensitivity to magnetic fields, this gyroscope is insensitive to magnetic fields and to other external perturbations. In addition, relative to prior nuclear-spin gyroscopes, this one exhibits greater sensitivity to rotation. There is commercial interest in development of small, highly sensitive gyroscopes. The present experimental device could be a prototype for development of nuclear spin gyroscopes suitable for navigation. In comparison with fiber-optic gyroscopes, these gyroscopes would draw less power and would be smaller, lighter, more sensitive, and less costly.

  15. Slow light Mach-Zehnder interferometer as label-free biosensor with scalable sensitivity

    DOE PAGES

    Qin, Kun; Hu, Shuren; Retterer, Scott T.; ...

    2016-02-05

    Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.

  16. Solar atmospheric neutrinos and the sensitivity floor for solar dark matter annihilation searches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Argüelles, C.A.; De Wasseige, G.; Fedynitch, A.

    Cosmic rays interacting in the solar atmosphere produce showers that result in a flux of high-energy neutrinos from the Sun. These form an irreducible background to indirect solar WIMP self-annihilation searches, which look for heavy dark matter particles annihilating into final states containing neutrinos in the Solar core. This background will eventually create a sensitivity floor for indirect WIMP self-annihilation searches analogous to that imposed by low-energy solar neutrino interactions for direct dark matter detection experiments. We present a new calculation of the flux of solar atmospheric neutrinos with a detailed treatment of systematic uncertainties inherent in solar atmospheric showermore » evolution, and we use this to derive the sensitivity floor for indirect solar WIMP annihilation analyses. We find that the floor lies less than one order of magnitude beyond the present experimental limits on spin-dependent WIMP-proton cross sections for some mass points, and that the high-energy solar atmospheric neutrino flux may be observable with running and future neutrino telescopes.« less

  17. High order statistical signatures from source-driven measurements of subcritical fissile systems

    NASA Astrophysics Data System (ADS)

    Mattingly, John Kelly

    1998-11-01

    This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility in a variety of applications. Potential applications include enhanced radiation signature identification of weapons components for nuclear disarmament and safeguards applications and augmented nondestructive analysis of spent nuclear fuel. In general, these techniques expand present capabilities in the analysis of subcritical measurements.

  18. Functional design of electrolytic biosensor

    NASA Astrophysics Data System (ADS)

    Gamage Preethichandra, D. M.; Mala Ekanayake, E. M. I.; Onoda, M.

    2017-11-01

    A novel amperometric biosensbased on conjugated polypyrrole (PPy) deposited on a Pt modified ITO (indium tin oxide) conductive glass substrate and their performances are described. We have presented a method of developing a highly sensitive and low-cost nano-biosensor for blood glucose measurements. The fabrication method proposed decreases the cost of production significantly as the amount of noble metals used is minimized. A nano-corrugated PPy substrate was developed through pulsed electrochemical deposition. The sensitivity achieved was 325 mA/(Mcm2) and the linear range of the developed sensor was 50-60 mmol/l. Then the application of the electrophoresis helps the glucose oxidase (GOx) on the PPy substrate. The main reason behind this high enzyme loading is the high electric field applied across the sensor surface (working electrode) and the counter electrode where that pushes the nano-scale enzyme particles floating in the phosphate buffer solution towards the substrate. The novel technique used has provided an extremely high sensitivities and very high linear ranges for enzyme (GOx) and therefore can be concluded that this is a very good technique to load enzyme onto the conducting polymer substrates.

  19. NAVIGATION PERFORMANCE IN HIGH EARTH ORBITS USING NAVIGATOR GPS RECEIVER

    NASA Technical Reports Server (NTRS)

    Bamford, William; Naasz, Bo; Moreau, Michael C.

    2006-01-01

    NASA GSFC has developed a GPS receiver that can acquire and track GPS signals with sensitivity significantly lower than conventional GPS receivers. This opens up the possibility of using GPS based navigation for missions in high altitude orbit, such as Geostationary Operational Environmental Satellites (GOES) in a geostationary orbit, and the Magnetospheric MultiScale (MMS) Mission, in highly eccentric orbits extending to 12 Earth radii and higher. Indeed much research has been performed to study the feasibility of using GPS navigation in high Earth orbits and the performance achievable. Recently, GSFC has conducted a series of hardware in-the-loop tests to assess the performance of this new GPS receiver in various high Earth orbits of interest. Tracking GPS signals to down to approximately 22-25 dB-Hz, including signals from the GPS transmitter side-lobes, steady-state navigation performance in a geostationary orbit is on the order of 10 meters. This paper presents the results of these tests, as well as sensitivity analysis to such factors as ionosphere masks, use of GPS side-lobe signals, and GPS receiver sensitivity.

  20. Fiber-Optic Refractometer Based on an Etched High-Q π-Phase-Shifted Fiber-Bragg-Grating

    PubMed Central

    Zhang, Qi; Ianno, Natale J.; Han, Ming

    2013-01-01

    We present a compact and highly-sensitive fiber-optic refractometer based on a high-Q π-phase-shifted fiber-Bragg-grating (πFBG) that is chemically etched to the core of the fiber. Due to the π phase-shift, a strong πFBG forms a high-Q optical resonator and the reflection spectrum features an extremely narrow notch that can be used for highly sensitivity refractive index measurement. The etched πFBG demonstrated here has a diameter of ∼9.3 μm and a length of only 7 mm, leading to a refractive index responsivity of 2.9 nm/RIU (RIU: refractive index unit) at an ambient refractive index of 1.318. The reflection spectrum of the etched πFBG features an extremely narrow notch with a linewidth of only 2.1 pm in water centered at ∼1,550 nm, corresponding to a Q-factor of 7.4 × 105, which allows for potentially significantly improved sensitivity over refractometers based on regular fiber Bragg gratings. PMID:23845932

  1. Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection: A Collaborative Meta-analysis.

    PubMed

    Pickering, John W; Than, Martin P; Cullen, Louise; Aldous, Sally; Ter Avest, Ewoud; Body, Richard; Carlton, Edward W; Collinson, Paul; Dupuy, Anne Marie; Ekelund, Ulf; Eggers, Kai M; Florkowski, Christopher M; Freund, Yonathan; George, Peter; Goodacre, Steve; Greenslade, Jaimi H; Jaffe, Allan S; Lord, Sarah J; Mokhtari, Arash; Mueller, Christian; Munro, Andrew; Mustapha, Sebbane; Parsonage, William; Peacock, W Frank; Pemberton, Christopher; Richards, A Mark; Sanchis, Juan; Staub, Lukas P; Troughton, Richard; Twerenbold, Raphael; Wildi, Karin; Young, Joanna

    2017-05-16

    High-sensitivity assays for cardiac troponin T (hs-cTnT) are sometimes used to rapidly rule out acute myocardial infarction (AMI). To estimate the ability of a single hs-cTnT concentration below the limit of detection (<0.005 µg/L) and a nonischemic electrocardiogram (ECG) to rule out AMI in adults presenting to the emergency department (ED) with chest pain. EMBASE and MEDLINE without language restrictions (1 January 2008 to 14 December 2016). Cohort studies involving adults presenting to the ED with possible acute coronary syndrome in whom an ECG and hs-cTnT measurements were obtained and AMI outcomes adjudicated during initial hospitalization. Investigators of studies provided data on the number of low-risk patients (no new ischemia on ECG and hs-cTnT measurements <0.005 µg/L) and the number who had AMI during hospitalization (primary outcome) or a major adverse cardiac event (MACE) or death within 30 days (secondary outcomes), by risk classification (low or not low risk). Two independent epidemiologists rated risk of bias of studies. Of 9241 patients in 11 cohort studies, 2825 (30.6%) were classified as low risk. Fourteen (0.5%) low-risk patients had AMI. Sensitivity of the risk classification for AMI ranged from 87.5% to 100% in individual studies. Pooled estimated sensitivity was 98.7% (95% CI, 96.6% to 99.5%). Sensitivity for 30-day MACEs ranged from 87.9% to 100%; pooled sensitivity was 98.0% (CI, 94.7% to 99.3%). No low-risk patients died. Few studies, variation in timing and methods of reference standard troponin tests, and heterogeneity of risk and prevalence of AMI across studies. A single hs-cTnT concentration below the limit of detection in combination with a nonischemic ECG may successfully rule out AMI in patients presenting to EDs with possible emergency acute coronary syndrome. Emergency Care Foundation.

  2. High-sensitivity bend angle measurements using optical fiber gratings.

    PubMed

    Rauf, Abdul; Zhao, Jianlin; Jiang, Biqiang

    2013-07-20

    We present a high-sensitivity and more flexible bend measurement method, which is based on the coupling of core mode to the cladding modes at the bending region in concatenation with optical fiber grating serving as band reflector. The characteristics of a bend sensing arm composed of bending region and optical fiber grating is examined for different configurations including single fiber Bragg grating (FBG), chirped FBG (CFBG), and double FBGs. The bend loss curves for coated, stripped, and etched sections of fiber in the bending region with FBG, CFBG, and double FBG are obtained experimentally. The effect of separation between bending region and optical fiber grating on loss is measured. The loss responses for single FBG and CFBG configurations are compared to discover the effectiveness for practical applications. It is demonstrated that the sensitivity of the double FBG scheme is twice that of the single FBG and CFBG configurations, and hence acts as sensitivity multiplier. The bend loss response for different fiber diameters obtained through etching in 40% hydrofluoric acid, is measured in double FBG scheme that resulted in a significant increase in the sensitivity, and reduction of dead-zone.

  3. An integrated approach to panic prevention targeting the empirically supported risk factors of smoking and anxiety sensitivity: theoretical basis and evidence from a pilot project evaluating feasibility and short-term efficacy.

    PubMed

    Feldner, Matthew T; Zvolensky, Michael J; Babson, Kimberly; Leen-Feldner, Ellen W; Schmidt, Norman B

    2008-10-01

    Consistent with a risk reduction model of targeted prevention, the present investigation piloted and empirically evaluated the feasibility and short-term efficacy of a first-generation panic prevention program that targeted two malleable risk factors for panic development-anxiety sensitivity and daily cigarette smoking. Members of a high risk cohort, defined by high levels of anxiety sensitivity and current daily smoking (n=96), were randomly assigned to either (1) a one session intervention focused on proximally increasing motivation to quit smoking and reducing anxiety sensitivity to distally prevent the development of panic or (2) a health information control condition of comparable length. Participants were followed for 6 months. Consistent with hypotheses, those in the treatment condition showed reduced anxiety sensitivity and this effect was maintained across the follow-up period. Limited evidence also suggested the intervention increased motivation to quit smoking. We discuss how this prevention protocol can be modified in the future to enhance its effects as part of second-generation larger-scale outcome evaluations.

  4. Trusted Computing Technologies, Intel Trusted Execution Technology.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guise, Max Joseph; Wendt, Jeremy Daniel

    2011-01-01

    We describe the current state-of-the-art in Trusted Computing Technologies - focusing mainly on Intel's Trusted Execution Technology (TXT). This document is based on existing documentation and tests of two existing TXT-based systems: Intel's Trusted Boot and Invisible Things Lab's Qubes OS. We describe what features are lacking in current implementations, describe what a mature system could provide, and present a list of developments to watch. Critical systems perform operation-critical computations on high importance data. In such systems, the inputs, computation steps, and outputs may be highly sensitive. Sensitive components must be protected from both unauthorized release, and unauthorized alteration: Unauthorizedmore » users should not access the sensitive input and sensitive output data, nor be able to alter them; the computation contains intermediate data with the same requirements, and executes algorithms that the unauthorized should not be able to know or alter. Due to various system requirements, such critical systems are frequently built from commercial hardware, employ commercial software, and require network access. These hardware, software, and network system components increase the risk that sensitive input data, computation, and output data may be compromised.« less

  5. Symptoms and signs associated with benign and malignant proximal fibular tumors: a clinicopathological analysis of 52 cases.

    PubMed

    Sun, Tao; Wang, Lingxiang; Guo, Changzhi; Zhang, Guochuan; Hu, Wenhai

    2017-05-02

    Malignant tumors in the proximal fibula are rare but life-threatening; however, biopsy is not routine due to the high risk of peroneal nerve injury. Our aim was to determine preoperative clinical indicators of malignancy. Between 2004 and 2016, 52 consecutive patients with proximal fibular tumors were retrospectively reviewed. Details of the clinicopathological characteristics including age, gender, location of tumors, the presenting symptoms, the duration of symptoms, and pathological diagnosis were collected. Descriptive statistics were calculated, and univariate and multivariate regression were performed. Of these 52 patients, 84.6% had benign tumors and 15.4% malignant tumors. The most common benign tumors were osteochondromas (46.2%), followed by enchondromas (13.5%) and giant cell tumors (13.5%). The most common malignancy was osteosarcomas (11.5%). The most common presenting symptoms were a palpable mass (52.0%) and pain (46.2%). Pain was the most sensitive (100%) and fourth specific (64%); both high skin temperature and peroneal nerve compression had the highest specificity (98%) and third sensitivity (64%); change in symptoms had the second highest specificity (89%) while 50% sensitivity. Using multivariate regression, palpable pain, high skin temperature, and peroneal nerve compression symptoms were predictors of malignancy. Most tumors in the proximal fibula are benign, and the malignancy is rare. Palpable pain, peroneal nerve compression symptoms, and high skin temperature were specific in predicting malignancy.

  6. Maternal Dispositional Empathy and Electrodermal Reactivity: Interactive Contributions to Maternal Sensitivity with Toddler-Aged Children

    PubMed Central

    Emery, Helen T.; McElwain, Nancy L.; Groh, Ashley M.; Haydon, Katherine C.; Roisman, Glenn I.

    2015-01-01

    The present study investigated maternal dispositional empathy and skin conductance level (SCL) reactivity to infant emotional cues as joint predictors of maternal sensitivity. Sixty-four mother-toddler dyads (31 boys) were observed across a series of interaction tasks during a laboratory visit, and maternal sensitivity was coded from approximately 55 minutes of observation per family. In a second, mother-only laboratory visit, maternal SCL reactivity to infant cues was assessed using a cry-laugh audio paradigm. Mothers reported on their dispositional empathy via a questionnaire. As hypothesized, mothers with greater dispositional empathy exhibited more sensitive behavior at low, but not high, levels of SCL reactivity to infant cues. Analyses examining self-reported emotional reactivity to the cry-laugh audio paradigm yielded a similar finding: dispositional empathy was related to greater sensitivity when mothers reported low, but not high, negative emotional reactivity. Results provide support for Dix’s (1991) affective model of parenting that underscores the combined contribution of the parent’s empathic tendencies and his/her own emotional experience in response to child emotions. Specificity of the Empathy × Reactivity interaction is discussed with respect to the context in which reactivity was assessed (infant cry versus laugh) and the type of sensitivity examined (sensitivity to the child’s distress versus non-distress). PMID:24955589

  7. Maternal dispositional empathy and electrodermal reactivity: Interactive contributions to maternal sensitivity with toddler-aged children.

    PubMed

    Emery, Helen T; McElwain, Nancy L; Groh, Ashley M; Haydon, Katherine C; Roisman, Glenn I

    2014-08-01

    The present study investigated maternal dispositional empathy and skin conductance level (SCL) reactivity to infant emotional cues as joint predictors of maternal sensitivity. Sixty-four mother-toddler dyads (31 boys) were observed across a series of interaction tasks during a laboratory visit, and maternal sensitivity was coded from approximately 55 minutes of observation per family. In a second, mother-only laboratory visit, maternal SCL reactivity to infant cues was assessed using a cry-laugh audio paradigm. Mothers reported on their dispositional empathy via a questionnaire. As hypothesized, mothers with greater dispositional empathy exhibited more sensitive behavior at low, but not high, levels of SCL reactivity to infant cues. Analyses examining self-reported emotional reactivity to the cry-laugh audio paradigm yielded a similar finding: Dispositional empathy was related to greater sensitivity when mothers reported low, but not high, negative emotional reactivity. Results provide support for Dix's (1991) affective model of parenting that underscores the combined contribution of the parent's empathic tendencies and his or her own emotional experience in response to child emotions. Specificity of the Empathy × Reactivity interaction is discussed with respect to the context in which reactivity was assessed (infant cry vs. laugh) and the type of sensitivity examined (sensitivity to the child's distress vs. nondistress).

  8. High Throughput Measurement of Locomotor Sensitization to Volatilized Cocaine in Drosophila melanogaster.

    PubMed

    Filošević, Ana; Al-Samarai, Sabina; Andretić Waldowski, Rozi

    2018-01-01

    Drosophila melanogaster can be used to identify genes with novel functional roles in neuronal plasticity induced by repeated consumption of addictive drugs. Behavioral sensitization is a relatively simple behavioral output of plastic changes that occur in the brain after repeated exposures to drugs of abuse. The development of screening procedures for genes that control behavioral sensitization has stalled due to a lack of high-throughput behavioral tests that can be used in genetically tractable organism, such as Drosophila . We have developed a new behavioral test, FlyBong, which combines delivery of volatilized cocaine (vCOC) to individually housed flies with objective quantification of their locomotor activity. There are two main advantages of FlyBong: it is high-throughput and it allows for comparisons of locomotor activity of individual flies before and after single or multiple exposures. At the population level, exposure to vCOC leads to transient and concentration-dependent increase in locomotor activity, representing sensitivity to an acute dose. A second exposure leads to further increase in locomotion, representing locomotor sensitization. We validate FlyBong by showing that locomotor sensitization at either the population or individual level is absent in the mutants for circadian genes period (per) , Clock (Clk) , and cycle (cyc) . The locomotor sensitization that is present in timeless (tim) and pigment dispersing factor (pdf) mutant flies is in large part not cocaine specific, but derived from increased sensitivity to warm air. Circadian genes are not only integral part of the neural mechanism that is required for development of locomotor sensitization, but in addition, they modulate the intensity of locomotor sensitization as a function of the time of day. Motor-activating effects of cocaine are sexually dimorphic and require a functional dopaminergic transporter. FlyBong is a new and improved method for inducing and measuring locomotor sensitization to cocaine in individual Drosophila . Because of its high-throughput nature, FlyBong can be used in genetic screens or in selection experiments aimed at the unbiased identification of functional genes involved in acute or chronic effects of volatilized psychoactive substances.

  9. High Throughput Measurement of Locomotor Sensitization to Volatilized Cocaine in Drosophila melanogaster

    PubMed Central

    Filošević, Ana; Al-samarai, Sabina; Andretić Waldowski, Rozi

    2018-01-01

    Drosophila melanogaster can be used to identify genes with novel functional roles in neuronal plasticity induced by repeated consumption of addictive drugs. Behavioral sensitization is a relatively simple behavioral output of plastic changes that occur in the brain after repeated exposures to drugs of abuse. The development of screening procedures for genes that control behavioral sensitization has stalled due to a lack of high-throughput behavioral tests that can be used in genetically tractable organism, such as Drosophila. We have developed a new behavioral test, FlyBong, which combines delivery of volatilized cocaine (vCOC) to individually housed flies with objective quantification of their locomotor activity. There are two main advantages of FlyBong: it is high-throughput and it allows for comparisons of locomotor activity of individual flies before and after single or multiple exposures. At the population level, exposure to vCOC leads to transient and concentration-dependent increase in locomotor activity, representing sensitivity to an acute dose. A second exposure leads to further increase in locomotion, representing locomotor sensitization. We validate FlyBong by showing that locomotor sensitization at either the population or individual level is absent in the mutants for circadian genes period (per), Clock (Clk), and cycle (cyc). The locomotor sensitization that is present in timeless (tim) and pigment dispersing factor (pdf) mutant flies is in large part not cocaine specific, but derived from increased sensitivity to warm air. Circadian genes are not only integral part of the neural mechanism that is required for development of locomotor sensitization, but in addition, they modulate the intensity of locomotor sensitization as a function of the time of day. Motor-activating effects of cocaine are sexually dimorphic and require a functional dopaminergic transporter. FlyBong is a new and improved method for inducing and measuring locomotor sensitization to cocaine in individual Drosophila. Because of its high-throughput nature, FlyBong can be used in genetic screens or in selection experiments aimed at the unbiased identification of functional genes involved in acute or chronic effects of volatilized psychoactive substances. PMID:29459820

  10. Motor and cognitive testing of bone marrow transplant patients after chemoradiotherapy

    NASA Technical Reports Server (NTRS)

    Parth, P.; Dunlap, W. P.; Kennedy, R. S.; Ordy, J. M.; Lane, N. E.

    1989-01-01

    Assessment of cognitive and motor performance of bone marrow transplant patients prior to, during, and following intensive toxic chemoradiotherapy may provide an important adjunct to measures of physiological and medical status. The present study is an attempt to assess whether, as side-effects, these aggressive treatments result in cognitive performance deficits, and if so, whether such changes recover posttreatment. Measurement of cognitive ability in this situation presents special problems not encountered with one-time tests intended for healthy adults. Such tests must be sensitive to changes within a single individual, which emphasizes the crucial importance of high reliability, stability across repeated-measures, and resistance to confounding factors such as motivation and fatigue. The present research makes use of a microbased portable test battery developed to have reliable and sensitive tests which were adapted to study the special requirements of transplant patients who may suffer cognitive deficits as a result of treatment. The results showed slight but significant changes in neuropsychological capacity when compared to baseline levels and controls, particularly near the beginning of treatment. The sensitivity of the battery in detecting such subtle temporary changes is discussed in terms of past research showing effects of other stressors, such as stimulated high altitude and ingestion of alcohol, on these measures.

  11. Ultrasensitive, highly selective, and real-time detection of protein using functionalized CNTs as MIP platform for FOSPR-based biosensor

    NASA Astrophysics Data System (ADS)

    Pathak, Anisha; Parveen, Shama; Gupta, Banshi D.

    2017-09-01

    A facile approach is presented for the detection of bovine serum albumin (BSA), based on fiber optic surface plasmon resonance (FOSPR) combined with molecular imprinting (MI). The probe is fabricated by exploiting the plasmonic property of silver thin film and vinyl-functionalised carbon nanotube-based MIP platform. BSA template molecules are imprinted on the MIP layer coated over multi-walled carbon nanotubes to ensure high specificity of the probe in the interfering environments. In addition, FOSPR endorses the sensor capability of real-time and remote sensing along with very high sensitivity due to the use of nanostructured MI platform. The response of the probe is considered in terms of the absorbance spectrum recorded for various concentrations of BSA. The sensor shows a wide dynamic range of 0-350 ng l-1 with a considerably linear response up to 100 ng l-1 in the peak absorbance wavelength with BSA concentration. A highest sensitivity of 0.862 nm per ng l-1 is achieved for the lowest concentration of BSA and it decreases with the increase in BSA concentration. The performance of the present sensor is compared with those reported in the literature in terms of the limit of detection. It is found that the probe possesses a lowest LOD of 0.386 ng l-1 in addition to other advantages such as real-time online monitoring, high sensitivity, high specificity, and remote sensing.

  12. High-resolution spectral analysis of ammonia near 6.2 μm using a cw EC-QCL coupled with cavity ring-down spectroscopy.

    PubMed

    Maithani, Sanchi; Mandal, Santanu; Maity, Abhijit; Pal, Mithun; Pradhan, Manik

    2018-04-30

    We report on the development of a mid-infrared cavity ring-down spectrometer (CRDS) coupled with a continuous wave (cw) external cavity quantum cascade laser (EC-QCL), operating between 6.0 μm and 6.3 μm, for high-resolution spectroscopic studies of ammonia (NH3) which served as a bench-mark molecule in this spectral region. We characterized the EC-QCL based CRDS system in detail and achieved a noise-equivalent absorption (NEA) coefficient of 2.11 × 10-9 cm-1 Hz-1/2 for a 100 Hz data acquisition rate. We thereafter exploited the system for high-resolution spectroscopic analysis of interference-free 10 transition lines of the ν4 fundamental vibrational band of NH3 centred at ∼6.2 μm. We probed the strongest interference-free absorption line RQ(4,3) of ν4, centred at 1613.370 cm-1 for highly-sensitive trace detection of NH3 and subsequently achieved a minimum detection sensitivity (1σ) of 2.78 × 109 molecules per cm3 which translated into the detection limit of 740 parts-per-trillion by volume (pptv/10-12) at a pressure of 115 Torr for an integration time of ∼167 seconds. To demonstrate the efficacy of the present system in real-life applications, we finally measured the mixing ratios of NH3 present in ambient air and human exhaled breath with high sensitivity and molecular specificity.

  13. Simultaneous and sensitive detection of six serotypes of botulinum neurotoxin using enzyme-linked immunosorbent assay-based protein antibody microarrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yanfeng; Lou, Jianlong; Jenko, Kathryn L.

    2012-11-15

    Botulinum neurotoxins (BoNTs), produced by Clostridium botulinum, are a group of seven (A-G) immunologically distinct proteins and cause the paralytic disease botulism. These toxins are the most poisonous substances known to humans and are potential bioweapon agents. Therefore, it is necessary to develop highly sensitive assays for the detection of BoNTs in both clinical and environmental samples. In the present study, we have developed an ELISA-based protein antibody microarray for the sensitive and simultaneous detection of BoNT serotype A, B, C, D, E and F. With engineered high-affinity antibodies, the assays have sensitivities in buffer of 8 fM (1.2 pg/mL)more » for serotypes A and B, and 32 fM (4.9 pg/mL) for serotypes C, D, E, and F. Using clinical and environmental samples (serum and milk), the microarray is capable of detecting BoNT/A-F to the same levels as in standard buffer. Cross reactivity between assays for individual serotype was also analyzed. These simultaneous, rapid, and sensitive assays have the potential to measure botulinum toxins in a high-throughput manner in complex clinical or environmental samples.« less

  14. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  15. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    Rahman, Atiar

    2006-01-01

    Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  16. High sensitive pulse oximeter-spectrophotometer for laser-optical dosimetry in biology and medicine

    NASA Astrophysics Data System (ADS)

    Asimov, M. M.; Asimov, R. M.; Rubinov, A. N.; Mamilov, S. A.; Plaksiy, Yu. S.

    2006-03-01

    High sensitive multi channel pulse oxymeter - spectrophotometer for control of the local tissue oxygen saturation is presented. Due to an original method of data storing and processing the accuracy of measurements 3-4 times are increased in compare with similar systems. This system is used for registration of the local changes of arterial blood saturation with oxygen under effect of low intensity laser radiation. It is shown that the photodissociation of oxyhemoglobin in cutaneous blood vessels play a dominant role in the mechanism of biostimulating and therapeutic effect of low intensity laser radiation. The results of experimental investigation in vivo the dependence of arterial oxygen blood saturation on temperature and the wavelength of laser radiation are presented. It is suggested that dosimetry for laser therapy could be base on regulation of local concentration of free oxygen in tissue.

  17. Pragmatic approach to chest pain patients discharged with undetectable high-sensitivity troponin T and normal electrocardiogram: the STABS + CT protocol.

    PubMed

    Bishop, Warrick; Girao, Gary

    2017-06-01

    A strategy that discharges chest pain patients with negative high-sensitivity troponin and non-ischaemic electrocardiography changes may still result in 0.44% of patients experiencing myocardial infarction within 30 days. We observed that a pragmatic approach that systematically discharged 25 patients on cardio-protective medications of aspirin, metoprolol and atorvastatin followed with prompt (<10 days) coronary computed tomography angiography resulted in no major adverse cardiac event and adverse drug reaction 30 days post-presentation. The strategy resulted in three patients (12%) ultimately diagnosed with likely unstable angina, which required planned coronary intervention in two patients and medical management in one patient. No unplanned readmissions for chest pains were noted from initial presentation through to 6-month follow up. © 2017 Royal Australasian College of Physicians.

  18. Fluorescent Nanomaterials for the Development of Latent Fingerprints in Forensic Sciences

    PubMed Central

    Li, Ming; Yu, Aoyang; Zhu, Ye

    2018-01-01

    This review presents an overview on the application of latent fingerprint development techniques in forensic sciences. At present, traditional developing methods such as powder dusting, cyanoacrylate fuming, chemical method, and small particle reagent method, have all been gradually compromised given their emerging drawbacks such as low contrast, sensitivity, and selectivity, as well as high toxicity. Recently, much attention has been paid to the use of fluorescent nanomaterials including quantum dots (QDs) and rare earth upconversion fluorescent nanomaterials (UCNMs) due to their unique optical and chemical properties. Thus, this review lays emphasis on latent fingerprint development based on QDs and UCNMs. Compared to latent fingerprint development by traditional methods, the new methods using fluorescent nanomaterials can achieve high contrast, sensitivity, and selectivity while showing reduced toxicity. Overall, this review provides a systematic overview on such methods. PMID:29657570

  19. A novel recession rate physics methodology for space applications at CIRA by means of CIRCE radioactive beam tracers

    NASA Astrophysics Data System (ADS)

    De Cesare, M.; Di Leva, A.; Del Vecchio, A.; Gialanella, L.

    2018-03-01

    Thermal protection systems (TPSs) of spacecrafts, either for single use or reusable, experience wear by ablation and erosion, due to the high heat fluxes during a re-entry phase in the atmosphere. The determination of the wear rate is a crucial point, which is presently mainly possible in aerospace on-ground measurements by means of invasive diagnostics. The purpose of this paper is to present novel contactless, online, high-sensitivity and non-intrusive diagnostics for wear measurements based on radioactive tracers. We propose the technique for future on-ground experiments that might later be developed to perform in-flight TPSs monitoring, thus significantly increasing the safety of the aerospace vehicles. The basic ideas of the method, its sensitivity investigated by GEANT4 simulations, and the future experimental validation are outlined.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qin, Kun; Hu, Shuren; Retterer, Scott T.

    Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.

  1. Advances with holographic DESA emulsions

    NASA Astrophysics Data System (ADS)

    Dünkel, Lothar; Eichler, Jürgen; Schneeweiss, Claudia; Ackermann, Gerhard

    2006-02-01

    DESA emulsions represent layer systems based on ultra-fine grained silver halide (AgX) technology. The new layers have an excellent performance for holographic application. The technology has been presented repeatedly in recent years, including the emulsion characterization and topics of chemical and spectral sensitization. The paper gives a survey of actual results referring to panchromatic sensitization and other improvements like the application of silver halide sensitized gelatine (SHSG) procedure. These results are embedded into intensive collaborations with small and medium enterprises (SME's) to commercialize DESA layers. Predominant goals are innovative products with holographic components and layers providing as well as cost effectiveness and high quality.

  2. In vivo emergence of HIV-1 highly sensitive to neutralizing antibodies.

    PubMed

    Aasa-Chapman, Marlén M I; Cheney, Kelly M; Hué, Stéphane; Forsman, Anna; O'Farrell, Stephen; Pellegrino, Pierre; Williams, Ian; McKnight, Áine

    2011-01-01

    The rapid and continual viral escape from neutralizing antibodies is well documented in HIV-1 infection. Here we report in vivo emergence of viruses with heightened sensitivity to neutralizing antibodies, sometimes paralleling the development of neutralization escape. Sequential viral envs were amplified from seven HIV-1 infected men monitored from seroconversion up to 5 years after infection. Env-recombinant infectious molecular clones were generated and tested for coreceptor use, macrophage tropism and neutralization sensitivity to homologous and heterologous serum, soluble CD4 and monoclonal antibodies IgG1b12, 2G12 and 17b. We found that HIV-1 evolves sensitivity to contemporaneous neutralizing antibodies during infection. Neutralization sensitive viruses grow out even when potent autologous neutralizing antibodies are present in patient serum. Increased sensitivity to neutralization was associated with susceptibility of the CD4 binding site or epitopes induced after CD4 binding, and mediated by complex envelope determinants including V3 and V4 residues. The development of neutralization sensitive viruses occurred without clinical progression, coreceptor switch or change in tropism for primary macrophages. We propose that an interplay of selective forces for greater virus replication efficiency without the need to resist neutralizing antibodies in a compartment protected from immune surveillance may explain the temporal course described here for the in vivo emergence of HIV-1 isolates with high sensitivity to neutralizing antibodies.

  3. Spectral Sensitivity of the ctenid spider Cupiennius salei Keys

    PubMed Central

    Zopf, Lydia M.; Schmid, Axel; Fredman, David; Eriksson, Bo Joakim

    2014-01-01

    Summary The spectral sensitivity of adult male Cupiennius salei Keys, a nocturnal hunting spider, was studied in a behavioural test. As known from earlier behavioural tests, C. salei walks towards a black target presented in front of a white background. In this study a black target (size 42 × 70 cm) was presented in a white arena illuminated by monochromatic light in the range of 365 to 695 nm using 19 monochromatic filters (HW in the range of 6 – 10 nm). In the first trial, the transmission of the optical filters was between 40 % and 80%. In a second trial the transmission was reduced to 5%, using a neutral density filter. At the high intensity the spiders showed a spectral sensivity in the range from 380 to 670 nm. In the second trial the animals only showed directed walks if the illumination was in the range of 449 to 599 nm, indicating a lower sensitivity at the margins of the spectral sensitivity. In previous intracellular recordings, the measured spectral sensitivity was between 320 and 620 nm. Interestingly, these results do not completely match the behaviourally tested spectral sensitivity of the photoreceptors, where the sensitivity range is shifted to longer wavelengths. In order to investigate the molecular background of spectral sensitivity, we searched for opsin genes in C. salei. We found three visual opsins that correspond to UV and middle to long wavelength sensitive opsins as described for jumping spiders. PMID:23948480

  4. A new signal amplification strategy of photoelectrochemical immunoassay for highly sensitive interleukin-6 detection based on TiO2/CdS/CdSe dual co-sensitized structure.

    PubMed

    Fan, Gao-Chao; Ren, Xiao-Lin; Zhu, Cheng; Zhang, Jian-Rong; Zhu, Jun-Jie

    2014-09-15

    Dual co-sensitized structure of TiO2/CdS/CdSe was designed to develop a novel photoelectrochemical immunoassay for highly sensitive detection of human interleukin-6 (IL-6). To construct a sensing electrode, TiO2/CdS hybrid was prepared by successive adsorption and reaction of Cd(2+) and S(2-) ions on the surface of TiO2 and then was employed as matrix for immobilization of anti-IL-6 antibody, whereas CdSe QDs linked to IL-6 were used for signal amplification via the specific antibody-antigen immunoreaction between anti-IL-6 and IL-6-CdSe bioconjugate. Greatly enhanced sensitivity for IL-6 detection was derived from the new co-sensitization signal amplification strategy. First, the TiO2/CdS/CdSe co-sensitized structure extended the absorption range to long wavelength of white light, which adequately utilized the light energy. Second, the TiO2/CdS/CdSe co-sensitized structure possessed stepwise band-edge levels favoring ultrafast transfer of photogenerated electrons and significantly prompted the photoelectrochemical performance. Besides, the introduction of CdSe effectively prevented the recombination of photogenerated electrons in the conduction band of CdS, further causing an enhanced photocurrent. Accordingly, upon the co-sensitization strategy, a novel immunoassay based on the competitive binding of anti-IL-6 antibody with IL-6 antigen and IL-6-CdSe bioconjugate was developed, and it exhibited a wide linear range from 1.0 pg/mL to 100 ng/mL with a low detection limit of 0.38 pg/mL for IL-6 detection. The proposed co-sensitization strategy presented high sensitivity, reproducibility, specificity and stability, and also opened up a new promising platform for detection of other biomarkers. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor.

    PubMed

    Dong, Yan; Son, Dong-Hyeok; Dai, Quan; Lee, Jun-Hyeok; Won, Chul-Ho; Kim, Jeong-Gil; Chen, Dunjun; Lee, Jung-Hee; Lu, Hai; Zhang, Rong; Zheng, Youdou

    2018-04-24

    The AlInN/GaN high-electron-mobility-transistor (HEMT) indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al 0.83 In 0.17 N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN) and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG) density and a thinner barrier layer in Al 0.83 In 0.17 N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  6. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avonto, Cristina; Chittiboyina, Amar G.; Rua, Diego

    2015-12-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles aftermore » incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow and critical parameters is presented. • The method could provide a useful tool to complement existing chemical assays.« less

  7. Upcoming planetary missions and the applicability of high temperature superconductor bolometers

    NASA Technical Reports Server (NTRS)

    Brasunas, J.; Kunde, V.; Moseley, H.; Lakew, B.

    1990-01-01

    Past and present planetary exploration is briefly reviewed, and the planned 1996 Cassini mission to Saturn and Titan is examined. The CIRS experiment aboard Cassini, which will retrieve information on the atmospheres of Titan and Saturn, is discussed. Ongoing efforts to build a high-sensitivity, high-Tc bolometer that would greatly improve detection in Titan's atmosphere are addressed.

  8. High-performance SERS substrate based on hybrid structure of graphene oxide/AgNPs/Cu film@pyramid Si

    NASA Astrophysics Data System (ADS)

    Li, Zhe; Xu, Shi Cai; Zhang, Chao; Liu, Xiao Yun; Gao, Sai Sai; Hu, Li Tao; Guo, Jia; Ma, Yong; Jiang, Shou Zhen; Si, Hai Peng

    2016-12-01

    We present a novel surface-enhanced Raman scattering (SERS) substrate based on graphene oxide/silver nanoparticles/copper film covered silicon pyramid arrays (GO/AgNPs/PCu@Si) by a low-cost and simple method. The GO/AgNPs/PCu@Si substrate presents high sensitivity, good homogeneity and well stability with R6G molecules as a probe. The detected concentration of Rhodamine 6 G (R6G) is as low as 10-15 M. These sensitive SERS behaviors are also confirmed in theory via a commercial COMSOL software, the electric field enhancement is not only formed between the AgNPs, but also formed between the AgNPs and Cu film. And the GO/AgNPs/PCu@Si substrates also present good property on practical application for the detection of methylene blue (MB) and crystal violet (CV). This work may offer a novel and practical method to facilitate the SERS applications in areas of medicine, food safety and biotechnology.

  9. High-performance SERS substrate based on hybrid structure of graphene oxide/AgNPs/Cu film@pyramid Si.

    PubMed

    Li, Zhe; Xu, Shi Cai; Zhang, Chao; Liu, Xiao Yun; Gao, Sai Sai; Hu, Li Tao; Guo, Jia; Ma, Yong; Jiang, Shou Zhen; Si, Hai Peng

    2016-12-07

    We present a novel surface-enhanced Raman scattering (SERS) substrate based on graphene oxide/silver nanoparticles/copper film covered silicon pyramid arrays (GO/AgNPs/PCu@Si) by a low-cost and simple method. The GO/AgNPs/PCu@Si substrate presents high sensitivity, good homogeneity and well stability with R6G molecules as a probe. The detected concentration of Rhodamine 6 G (R6G) is as low as 10 -15 M. These sensitive SERS behaviors are also confirmed in theory via a commercial COMSOL software, the electric field enhancement is not only formed between the AgNPs, but also formed between the AgNPs and Cu film. And the GO/AgNPs/PCu@Si substrates also present good property on practical application for the detection of methylene blue (MB) and crystal violet (CV). This work may offer a novel and practical method to facilitate the SERS applications in areas of medicine, food safety and biotechnology.

  10. High-performance SERS substrate based on hybrid structure of graphene oxide/AgNPs/Cu film@pyramid Si

    PubMed Central

    Li, Zhe; Xu, Shi Cai; Zhang, Chao; Liu, Xiao Yun; Gao, Sai Sai; Hu, Li Tao; Guo, Jia; Ma, Yong; Jiang, Shou Zhen; Si, Hai Peng

    2016-01-01

    We present a novel surface-enhanced Raman scattering (SERS) substrate based on graphene oxide/silver nanoparticles/copper film covered silicon pyramid arrays (GO/AgNPs/PCu@Si) by a low-cost and simple method. The GO/AgNPs/PCu@Si substrate presents high sensitivity, good homogeneity and well stability with R6G molecules as a probe. The detected concentration of Rhodamine 6 G (R6G) is as low as 10−15 M. These sensitive SERS behaviors are also confirmed in theory via a commercial COMSOL software, the electric field enhancement is not only formed between the AgNPs, but also formed between the AgNPs and Cu film. And the GO/AgNPs/PCu@Si substrates also present good property on practical application for the detection of methylene blue (MB) and crystal violet (CV). This work may offer a novel and practical method to facilitate the SERS applications in areas of medicine, food safety and biotechnology. PMID:27924863

  11. Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression

    NASA Astrophysics Data System (ADS)

    Wong, Chak P.; Gump, Jared C.

    2006-07-01

    Explosive formulations with reduced-sensitivity RDX showed reduced shock sensitivity using Naval Ordnance Laboratory (NOL) Large Scale Gap Test, compared with similar formulations using standard RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light on the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. I-RDX®, a form of reduced- sensitivity RDX was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transform IR (FTIR). The pressure dependence of the Raman mode frequencies of I-RDX® was determined and compared with that of standard RDX. The behavior of I-RDX® near the pressure at which standard RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph is presented.

  12. The severity of nocturnal hypoxia but not abdominal adiposity is associated with insulin resistance in non-obese men with sleep apnea.

    PubMed

    Borel, Anne-Laure; Monneret, Denis; Tamisier, Renaud; Baguet, Jean-Philippe; Faure, Patrice; Levy, Patrick; Halimi, Serge; Pépin, Jean-Louis

    2013-01-01

    Beyond obesity, sleep apnea syndrome is frequently associated with excess abdominal adiposity that could contribute to the deteriorated cardiometabolic risk profile of apneic patients. The present study addressed the respective contribution of the severity of sleep apnea syndrome and excess abdominal adiposity to the cardiometabolic risk profile of 38 non obese men with polysomnography-diagnosed sleep apnea syndrome (apnea-hypopnea index >15 events/hour). These otherwise healthy men performed a 75g-oral glucose tolerance test (OGTT) with plasma lipid/inflammatory and redox profiles. Twenty-one apneic men with high-waist circumference (>94 cm) were compared to 17 apneic men with low-waist circumference. Apneic men with high-waist circumference had higher AUC glucose and AUC insulin than apneic men with low-waist circumference. Accordingly, apneic men with high-waist circumference had higher hepatic insulin resistance as reflected by higher HOMA-resistance index, and lower global insulin sensitivity as reflected by lower insulin sensitivity index of Matsuda (derived from OGTT). The sleep structure and the apnea-hypopnea index were not different between the two groups. However, apneic men with high-waist circumference presented with lower mean nocturnal oxyhemoglobin (SpO2). In the 38 men, waist circumference and mean nocturnal SpO2 were inversely correlated (r = -0.43, p = 0.011) and were both associated with plasma glucose/insulin homeostasis indices: the higher the waist circumference, the lower the mean nocturnal SpO2, the lower the insulin-sensitivity. Finally, in multivariable regression model, mean nocturnal SpO2 and not waist circumference was associated with insulin-resistance. Thus, excess abdominal adiposity in non obese apneic men was associated with a deteriorated insulin-sensitivity that could be driven by a more severe nocturnal hypoxemia.

  13. Limited copy number - high resolution melting (LCN-HRM) enables the detection and identification by sequencing of low level mutations in cancer biopsies

    PubMed Central

    Do, Hongdo; Dobrovic, Alexander

    2009-01-01

    Background Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations. We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Results Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions. LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. Conclusion LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations. PMID:19811662

  14. Limited copy number-high resolution melting (LCN-HRM) enables the detection and identification by sequencing of low level mutations in cancer biopsies.

    PubMed

    Do, Hongdo; Dobrovic, Alexander

    2009-10-08

    Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations.We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions.LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations.

  15. Analytical validation of a next generation sequencing liquid biopsy assay for high sensitivity broad molecular profiling.

    PubMed

    Plagnol, Vincent; Woodhouse, Samuel; Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg; Forshew, Tim

    2018-01-01

    Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications.

  16. Analytical validation of a next generation sequencing liquid biopsy assay for high sensitivity broad molecular profiling

    PubMed Central

    Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg

    2018-01-01

    Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications. PMID:29543828

  17. A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring.

    PubMed

    Yang, Tingting; Jiang, Xin; Zhong, Yujia; Zhao, Xuanliang; Lin, Shuyuan; Li, Jing; Li, Xinming; Xu, Jianlong; Li, Zhihong; Zhu, Hongwei

    2017-07-28

    Profuse medical information about cardiovascular properties can be gathered from pulse waveforms. Therefore, it is desirable to design a smart pulse monitoring device to achieve noninvasive and real-time acquisition of cardiovascular parameters. The majority of current pulse sensors are usually bulky or insufficient in sensitivity. In this work, a graphene-based skin-like sensor is explored for pulse wave sensing with features of easy use and wearing comfort. Moreover, the adjustment of the substrate stiffness and interfacial bonding accomplish the optimal balance between sensor linearity and signal sensitivity, as well as measurement of the beat-to-beat radial arterial pulse. Compared with the existing bulky and nonportable clinical instruments, this highly sensitive and soft sensing patch not only provides primary sensor interface to human skin, but also can objectively and accurately detect the subtle pulse signal variations in a real-time fashion, such as pulse waveforms with different ages, pre- and post-exercise, thus presenting a promising solution to home-based pulse monitoring.

  18. Preparation of pH-sensitive anionic liposomes designed for drug delivery system (DDS) application.

    PubMed

    Aoki, Asami; Akaboshi, Hikaru; Ogura, Taku; Aikawa, Tatsuo; Kondo, Takeshi; Tobori, Norio; Yuasa, Makoto

    2015-01-01

    We prepared pH-sensitive anionic liposomes composed solely of anionic bilayer membrane components that were designed to promote efficient release of entrapped agents in response to acidic pH. The pH-sensitive anionic liposomes showed high dispersion stability at neutral pH, but the fluidity of the bilayer membrane was enhanced in an acidic environment. These liposomes were rather simple and were composed of dimyristoylphosphatidylcholine (DMPC), an anionic bilayer membrane component, and polyoxyethylene sorbitan monostearate (Tween 80). In particular, the present pH-sensitive anionic liposomes showed higher temporal stability than those of conventional DMPC/DPPC liposomes. We found that pHsensitive properties strongly depended on the molecular structure, pKa value, and amount of an incorporated anionic bilayer membrane component, such as sodium oleate (SO), dimyristoylphosphatidylserine (DMPS), or sodium β-sitosterol sulfate (SS). These results provide an opportunity to manipulate liposomal stability in a pH-dependent manner, which could lead to the formulation of a high performance drug delivery system (DDS).

  19. Sigh rate during emotional transitions: More evidence for a sigh of relief.

    PubMed

    Vlemincx, Elke; Meulders, Michel; Abelson, James L

    2017-04-01

    Evidence suggests that sighs regulate stress and emotions, e.g. by facilitating relief. This study aimed to investigate sigh rates during relief. In addition, links between sighs, anxiety sensitivity and HPA-axis activity were explored. Healthy volunteers (N=29) were presented cues predicting the valence of subsequent stimuli. By sequencing cues that predicted pleasant or unpleasant stimuli with or without certainty, transitions to certain pleasantness (relief) or to certain unpleasantness (control) were created and compared to no transitions. Salivary cortisol, anxiety sensitivity and respiration were measured. Sigh frequency was significantly higher during relief than during control transitions and no transition states, and higher during control transitions than during no transition states. Sigh frequency increased with steeper cortisol declines for high anxiety sensitive persons. Results confirm a relationship between sighs and relief. In addition, results suggest that sigh frequency is importantly related to HPA-axis activity, particularly in high anxiety sensitive persons. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A Monte Carlo study of different detector geometries for HAWC

    NASA Astrophysics Data System (ADS)

    Gebauer, Iris

    Compared to other parts of astronomy the study of the universe at energies above 100GeV is a relatively new field. Pointed instruments presently achieve the highest sensitivities. They have detected gamma-rays from at least 10 sources, but they are only able to monitor a relatively small fraction of the sky. The detection of exciting phenomena such as Gamma-ray Bursts (GRBs) requires a highly sensitive detector capable of continuously monitoring the entire overhead sky. Such an instrument could make an unbiased study of the entire field of view. With sufficient sensitivity it could detect short transients (~ 15 minutes) and study the time structure of Active galactic nuclei (AGN) flares at energies unattainable to space-based instruments. This thesis describes the design and performance of the next generation water Cherenkov detector HAWC (High Altitude Water Cherenkov). Focussing on the performance in background-rejection and sensitivity to point sources, two possible detector geometries, different in the way the photomultipliers (PMTs) are separated from each other, are compared.

  1. An ultra-sensitive wearable accelerometer for continuous heart and lung sound monitoring.

    PubMed

    Hu, Yating; Xu, Yong

    2012-01-01

    This paper presents a chest-worn accelerometer with high sensitivity for continuous cardio-respiratory sound monitoring. The accelerometer is based on an asymmetrical gapped cantilever which is composed of a bottom mechanical layer and a top piezoelectric layer separated by a gap. This novel structure helps to increase the sensitivity by orders of magnitude compared with conventional cantilever based accelerometers. The prototype with a resonant frequency of 1100Hz and a total weight of 5 gram is designed, constructed and characterized. The size of the prototype sensor is 35mm×18mm×7.8mm (l×w×t). A built-in charge amplifier is used to amplify the output voltage of the sensor. A sensitivity of 86V/g and a noise floor of 40ng/√Hz are obtained. Preliminary tests for recording both cardiac and respiratory signals are carried out on human body and the new sensor exhibits better performance compared with a high-end electronic stethoscope.

  2. Application research on the sensitivity of porous silicon

    NASA Astrophysics Data System (ADS)

    Xu, Gaobin; Xi, Ye; Chen, Xing; Ma, Yuanming

    2017-09-01

    Applications based on sensitive property of porous silicon (PSi) were researched. As a kind of porous material, the feasibility of PSi as a getter material was studied. Five groups of samples with different parameters were prepared. The gas-sensing property of PSi was studied by the test system and suitable parameters of PSi were also discussed. Meanwhile a novel structure of humidity sensor, using porous silicon as humidity-sensitive material, based on MEMS process has been successfully designed. The humidity-sensing properties were studied by a test system. Because of the polysilicon layer deposited upon the PSi layer, the humidity sensor can realize a quick dehumidification by itself. To extend service life and reduce the effect of the environment, a passivation layer (Si3N4) was also deposited on the surface of electrodes. The result indicated the novel humidity sensor presented high sensitivity (1.1 pF/RH%), low hysteresis, low temperature coefficient (0.5%RH/°C) and high stability.

  3. Piezoresistive method for a laser induced shock wave detection on solids

    NASA Astrophysics Data System (ADS)

    Gonzalez-Romero, R.; Garcia-Torales, G.; Gomez Rosas, G.; Strojnik, M.

    2017-08-01

    A laser shock wave is a mechanical high-pressure impulse with a duration of a few nanoseconds induced by a high power laser pulse. We performed wave pressure measurements in order to build and check mathematical models. They are used for wave applications in material science, health, and defense, to list a few. Piezoresistive methods have been shown to be highly sensitive, linear, and highly appropriate for practical implementation, compared with piezoelectric methods employed in shock wave pressure measurements. In this work, we develop a novel method to obtain the sensitivity of a piezoresistive measurement system. The results shows that it is possible to use a mechanical method to measure pressure of a laser induced shock wave in nanosecond range. Experimental pressure measurements are presented.

  4. Stretchable Platinum Network-Based Transparent Electrodes for Highly Sensitive Wearable Electronics.

    PubMed

    Wang, Yuting; Cheng, Jing; Xing, Yan; Shahid, Muhammad; Nishijima, Hiroki; Pan, Wei

    2017-07-01

    A platinum network-based transparent electrode has been fabricated by electrospinning. The unique nanobelt structured electrode demonstrates low sheet resistance (about 16 Ω sq -1 ) and high transparency of 80% and excellent flexibility. One of the most interesting demonstrations of this Pt nanobelt electrode is its excellent reversibly resilient characteristic. The electric conductivity of the flexible Pt electrode can recover to its initial value after 160% extending and this performance is repeatable and stable. The good linear relationship between the resistance and strain of the unique structured Pt electrode makes it possible to assemble a wearable high sensitive strain sensor. Present reported Pt nanobelt electrode also reveals potential applications in electrode for flexible fuel cells and highly transparent ultraviolet (UV) sensors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. High-sensitivity explosives detection using dual-excitation-wavelength resonance-Raman detector

    NASA Astrophysics Data System (ADS)

    Yellampalle, Balakishore; McCormick, William B.; Wu, Hai-Shan; Sluch, Mikhail; Martin, Robert; Ice, Robert V.; Lemoff, Brian

    2014-05-01

    A key challenge for standoff explosive sensors is to distinguish explosives, with high confidence, from a myriad of unknown background materials that may have interfering spectral peaks. To meet this challenge a sensor needs to exhibit high specificity and high sensitivity in detection at low signal-to-noise ratio levels. We had proposed a Dual-Excitation- Wavelength Resonance-Raman Detector (DEWRRED) to address this need. In our previous work, we discussed various components designed at WVHTCF for a DEWRRED sensor. In this work, we show a completely assembled laboratory prototype of a DEWRRED sensor and utilize it to detect explosives from two standoff distances. The sensor system includes two novel, compact CW deep-Ultraviolet (DUV) lasers, a compact dual-band high throughput DUV spectrometer, and a highly-sensitive detection algorithm. We choose DUV excitation because Raman intensities from explosive traces are enhanced and fluorescence and solar background are not present. The DEWRRED technique exploits the excitation wavelength dependence of Raman signal strength, arising from complex interplay of resonant enhancement, self-absorption and laser penetration depth. We show measurements from >10 explosives/pre-cursor materials at different standoff distances. The sensor showed high sensitivity in explosive detection even when the signalto- noise ratio was close to one (~1.6). We measured receiver-operating-characteristics, which show a clear benefit in using the dual-excitation-wavelength technique as compared to a single-excitation-wavelength technique. Our measurements also show improved specificity using the amplitude variation information in the dual-excitation spectra.

  6. Biomimetic micromechanical adaptive flow-sensor arrays

    NASA Astrophysics Data System (ADS)

    Krijnen, Gijs; Floris, Arjan; Dijkstra, Marcel; Lammerink, Theo; Wiegerink, Remco

    2007-05-01

    We report current developments in biomimetic flow-sensors based on flow sensitive mechano-sensors of crickets. Crickets have one form of acoustic sensing evolved in the form of mechanoreceptive sensory hairs. These filiform hairs are highly perceptive to low-frequency sound with energy sensitivities close to thermal threshold. In this work we describe hair-sensors fabricated by a combination of sacrificial poly-silicon technology, to form silicon-nitride suspended membranes, and SU8 polymer processing for fabrication of hairs with diameters of about 50 μm and up to 1 mm length. The membranes have thin chromium electrodes on top forming variable capacitors with the substrate that allow for capacitive read-out. Previously these sensors have been shown to exhibit acoustic sensitivity. Like for the crickets, the MEMS hair-sensors are positioned on elongated structures, resembling the cercus of crickets. In this work we present optical measurements on acoustically and electrostatically excited hair-sensors. We present adaptive control of flow-sensitivity and resonance frequency by electrostatic spring stiffness softening. Experimental data and simple analytical models derived from transduction theory are shown to exhibit good correspondence, both confirming theory and the applicability of the presented approach towards adaptation.

  7. Optimization of Passive Low Power Wireless Electromagnetic Energy Harvesters

    PubMed Central

    Nimo, Antwi; Grgić, Dario; Reindl, Leonhard M.

    2012-01-01

    This work presents the optimization of antenna captured low power radio frequency (RF) to direct current (DC) power converters using Schottky diodes for powering remote wireless sensors. Linearized models using scattering parameters show that an antenna and a matched diode rectifier can be described as a form of coupled resonator with different individual resonator properties. The analytical models show that the maximum voltage gain of the coupled resonators is mainly related to the antenna, diode and load (remote sensor) resistances at matched conditions or resonance. The analytical models were verified with experimental results. Different passive wireless RF power harvesters offering high selectivity, broadband response and high voltage sensitivity are presented. Measured results show that with an optimal resistance of antenna and diode, it is possible to achieve high RF to DC voltage sensitivity of 0.5 V and efficiency of 20% at −30 dBm antenna input power. Additionally, a wireless harvester (rectenna) is built and tested for receiving range performance. PMID:23202014

  8. Optimization of passive low power wireless electromagnetic energy harvesters.

    PubMed

    Nimo, Antwi; Grgić, Dario; Reindl, Leonhard M

    2012-10-11

    This work presents the optimization of antenna captured low power radio frequency (RF) to direct current (DC) power converters using Schottky diodes for powering remote wireless sensors. Linearized models using scattering parameters show that an antenna and a matched diode rectifier can be described as a form of coupled resonator with different individual resonator properties. The analytical models show that the maximum voltage gain of the coupled resonators is mainly related to the antenna, diode and load (remote sensor) resistances at matched conditions or resonance. The analytical models were verified with experimental results. Different passive wireless RF power harvesters offering high selectivity, broadband response and high voltage sensitivity are presented. Measured results show that with an optimal resistance of antenna and diode, it is possible to achieve high RF to DC voltage sensitivity of 0.5 V and efficiency of 20% at -30 dBm antenna input power. Additionally, a wireless harvester (rectenna) is built and tested for receiving range performance.

  9. Multimodal imaging system for dental caries detection

    NASA Astrophysics Data System (ADS)

    Liang, Rongguang; Wong, Victor; Marcus, Michael; Burns, Peter; McLaughlin, Paul

    2007-02-01

    Dental caries is a disease in which minerals of the tooth are dissolved by surrounding bacterial plaques. A caries process present for some time may result in a caries lesion. However, if it is detected early enough, the dentist and dental professionals can implement measures to reverse and control caries. Several optical, nonionized methods have been investigated and used to detect dental caries in early stages. However, there is not a method that can singly detect the caries process with both high sensitivity and high specificity. In this paper, we present a multimodal imaging system that combines visible reflectance, fluorescence, and Optical Coherence Tomography (OCT) imaging. This imaging system is designed to obtain one or more two-dimensional images of the tooth (reflectance and fluorescence images) and a three-dimensional OCT image providing depth and size information of the caries. The combination of two- and three-dimensional images of the tooth has the potential for highly sensitive and specific detection of dental caries.

  10. High-speed high-sensitivity infrared spectroscopy using mid-infrared swept lasers (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Childs, David T. D.; Groom, Kristian M.; Hogg, Richard A.; Revin, Dmitry G.; Cockburn, John W.; Rehman, Ihtesham U.; Matcher, Stephen J.

    2016-03-01

    Infrared spectroscopy is a highly attractive read-out technology for compositional analysis of biomedical specimens because of its unique combination of high molecular sensitivity without the need for exogenous labels. Traditional techniques such as FTIR and Raman have suffered from comparatively low speed and sensitivity however recent innovations are challenging this situation. Direct mid-IR spectroscopy is being speeded up by innovations such as MEMS-based FTIR instruments with very high mirror speeds and supercontinuum sources producing very high sample irradiation levels. Here we explore another possible method - external cavity quantum cascade lasers (EC-QCL's) with high cavity tuning speeds (mid-IR swept lasers). Swept lasers have been heavily developed in the near-infrared where they are used for non-destructive low-coherence imaging (OCT). We adapt these concepts in two ways. Firstly by combining mid-IR quantum cascade gain chips with external cavity designs adapted from OCT we achieve spectral acquisition rates approaching 1 kHz and demonstrate potential to reach 100 kHz. Secondly we show that mid-IR swept lasers share a fundamental sensitivity advantage with near-IR OCT swept lasers. This makes them potentially able to achieve the same spectral SNR as an FTIR instrument in a time x N shorter (N being the number of spectral points) under otherwise matched conditions. This effect is demonstrated using measurements of a PDMS sample. The combination of potentially very high spectral acquisition rates, fundamental SNR advantage and the use of low-cost detector systems could make mid-IR swept lasers a powerful technology for high-throughput biomedical spectroscopy.

  11. Face Configuration Accuracy and Processing Speed among Adults with High-Functioning Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Faja, Susan; Webb, Sara Jane; Merkle, Kristen; Aylward, Elizabeth; Dawson, Geraldine

    2009-01-01

    The present study investigates the accuracy and speed of face processing employed by high-functioning adults with autism spectrum disorders (ASDs). Two behavioral experiments measured sensitivity to distances between features and face recognition when performance depended on holistic versus featural information. Results suggest adults with ASD…

  12. Simultaneous multi-headed imager geometry calibration method

    DOEpatents

    Tran, Vi-Hoa [Newport News, VA; Meikle, Steven Richard [Penshurst, AU; Smith, Mark Frederick [Yorktown, VA

    2008-02-19

    A method for calibrating multi-headed high sensitivity and high spatial resolution dynamic imaging systems, especially those useful in the acquisition of tomographic images of small animals. The method of the present invention comprises: simultaneously calibrating two or more detectors to the same coordinate system; and functionally correcting for unwanted detector movement due to gantry flexing.

  13. Aptamer-mediated 'turn-off/turn-on' nanozyme activity of gold nanoparticles for kanamycin detection.

    PubMed

    Sharma, Tarun Kumar; Ramanathan, Rajesh; Weerathunge, Pabudi; Mohammadtaheri, Mahsa; Daima, Hemant Kumar; Shukla, Ravi; Bansal, Vipul

    2014-12-28

    A new ultrafast and highly sensitive 'turn-off/turn-on' biosensing approach that combines the intrinsic peroxidase-like activity of gold nanoparticles (GNPs) with the high affinity and specificity of a ssDNA aptamer is presented for the efficient detection of a model small molecule kanamycin.

  14. Development of a highly sensitive chemiluminescence enzyme immunoassay using enhanced luminol as substrate.

    PubMed

    Tao, Xiaoqi; Wang, Wenjun; Wang, Zhanhui; Cao, Xingyuan; Zhu, Jinghui; Niu, Lanlan; Wu, Xiaoping; Jiang, Haiyang; Shen, Jianzhong

    2014-06-01

    In this study, a high sensitivity chemiluminescence enzyme immunoassay (CLEIA) based on novel enhancers was developed. Under optimal conditions, we developed an enhanced chemiluminescence reaction (ECR) catalyzed by horseradish peroxidase (HRP-C) in the presence of 3-(10'-phenothiazinyl) propane-1-sulfonate (SPTZ) and 4-morpholinopyridine (MORP) as enhancers. The limit of detection of the newly prepared chemiluminescent cocktail for HRP was 0.33 pg/well, which is lower than that of commercial Super Signal substrate. The results showed that this novel chemiluminescent cocktail can significantly increase the light output of HRP-catalyzed ECR, which can be translated into a corresponding improvement in sensitivity. Similar improvements were observed in CLEIA for the determination of chloramphenicol in milk. In addition, the ECR of N-azoles as secondary enhancer was also presented. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Highly Sensitive Quantitative PCR for the Detection and Differentiation of Pseudogymnoascus destructans and Other Pseudogymnoascus Species

    PubMed Central

    Shuey, Megan M.; Drees, Kevin P.; Lindner, Daniel L.; Keim, Paul

    2014-01-01

    White-nose syndrome is a fungal disease that has decimated bat populations across eastern North America. Identification of the etiologic agent, Pseudogymnoascus destructans (formerly Geomyces destructans), in environmental samples is essential to proposed management plans. A major challenge is the presence of closely related species, which are ubiquitous in many soils and cave sediments and often present in high abundance. We present a dual-probe real-time quantitative PCR assay capable of detecting and differentiating P. destructans from closely related fungi in environmental samples from North America. The assay, based on a single nucleotide polymorphism (SNP) specific to P. destructans, is capable of rapid low-level detection from various sampling media, including sediment, fecal samples, wing biopsy specimens, and skin swabs. This method is a highly sensitive, high-throughput method for identifying P. destructans, other Pseudogymnoascus spp., and Geomyces spp. in the environment, providing a fundamental component of research and risk assessment for addressing this disease, as well as other ecological and mycological work on related fungi. PMID:24375140

  16. Stimulated Raman scattering (SRS) spectroscopic OCT (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Robles, Francisco E.; Zhou, Kevin C.; Fischer, Martin C.; Warren, Warren S.

    2017-02-01

    Optical coherence tomography (OCT) enables non-invasive, high-resolution, tomographic imaging of biological tissues by leveraging principles of low coherence interferometry; however, OCT lacks molecular specificity. Spectroscopic OCT (SOCT) overcomes this limitation by providing depth-resolved spectroscopic signatures of chromophores, but SOCT has been limited to a couple of endogenous molecules, namely hemoglobin and melanin. Stimulated Raman scattering, on the other hand, can provide highly specific molecular information of many endogenous species, but lacks the spatial and spectral multiplexing capabilities of SOCT. In this work we integrate the two methods, SRS and SOCT, to enable simultaneously multiplexed spatial and spectral imaging with sensitivity to many endogenous biochemical species that play an important role in biology and medicine. The method, termed SRS-SOCT, has the potential to achieve fast, volumetric, and highly sensitive label-free molecular imaging, which would be valuable for many applications. We demonstrate the approach by imaging excised human adipose tissue and detecting the lipids' Raman signatures in the high-wavenumber region. Details of this method along with validations and results will be presented.

  17. Milagro limits and HAWC sensitivity for the rate-density of evaporating primordial black holes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdo, A. A.; Abeysekara, A. U.; Alfaro, R.

    Primordial Black Holes (PBHs) are gravitationally collapsed objects that may have been created by density fluctuations in the early universe and could have arbitrarily small masses down to the Planck scale. Hawking showed that due to quantum effects, a black hole has a temperature inversely proportional to its mass and will emit all species of fundamental particles thermally. PBHs with initial masses of ~ 5.0 × 10¹⁴ g should be expiring in the present epoch with bursts of high-energy particles, including gamma radiation in the GeV – TeV energy range. The Milagro high energy observatory, which operated from 2000 tomore » 2008, is sensitive to the high end of the PBH evaporation gamma-ray spectrum. Due to its large field-of-view, more than 90% duty cycle and sensitivity up to 100 TeV gamma rays, the Milagro observatory is well suited to perform a search for PBH bursts. Based on a search on the Milagro data, we report new PBH burst rate density upper limits over a range of PBH observation times. In addition, we report the sensitivity of the Milagro successor, the High Altitude Water Cherenkov (HAWC) observatory, to PBH evaporation events.« less

  18. Milagro limits and HAWC sensitivity for the rate-density of evaporating primordial black holes

    DOE PAGES

    Abdo, A. A.; Abeysekara, A. U.; Alfaro, R.; ...

    2015-04-01

    Primordial Black Holes (PBHs) are gravitationally collapsed objects that may have been created by density fluctuations in the early universe and could have arbitrarily small masses down to the Planck scale. Hawking showed that due to quantum effects, a black hole has a temperature inversely proportional to its mass and will emit all species of fundamental particles thermally. PBHs with initial masses of ~ 5.0 × 10¹⁴ g should be expiring in the present epoch with bursts of high-energy particles, including gamma radiation in the GeV – TeV energy range. The Milagro high energy observatory, which operated from 2000 tomore » 2008, is sensitive to the high end of the PBH evaporation gamma-ray spectrum. Due to its large field-of-view, more than 90% duty cycle and sensitivity up to 100 TeV gamma rays, the Milagro observatory is well suited to perform a search for PBH bursts. Based on a search on the Milagro data, we report new PBH burst rate density upper limits over a range of PBH observation times. In addition, we report the sensitivity of the Milagro successor, the High Altitude Water Cherenkov (HAWC) observatory, to PBH evaporation events.« less

  19. Pressure sensing in high-refractive-index liquids using long-period gratings nanocoated with silicon nitride.

    PubMed

    Smietana, Mateusz; Bock, Wojtek J; Mikulic, Predrag; Chen, Jiahua

    2010-01-01

    The paper presents a novel pressure sensor based on a silicon nitride (SiNx) nanocoated long-period grating (LPG). The high-temperature, radio-frequency plasma-enhanced chemical-vapor-deposited (RF PECVD) SiNx nanocoating was applied to tune the sensitivity of the LPG to the external refractive index. The technique allows for deposition of good quality, hard and wear-resistant nanofilms as required for optical sensors. Thanks to the SiNx nanocoating it is possible to overcome a limitation of working in the external-refractive-index range, which for a bare fiber cannot be close to that of the cladding. The nanocoated LPG-based sensing structure we developed is functional in high-refractive-index liquids (nD>1.46) such as oil or gasoline, with pressure sensitivity as high as when water is used as a working liquid. The nanocoating developed for this experiment not only has the highest refractive index ever achieved in LPGs (n>2.2 at λ=1,550 nm), but is also the thinnest (<100 nm) able to tune the external-refractive-index sensitivity of the gratings. To the best of our knowledge, this is the first time a nanocoating has been applied on LPGs that is able to simultaneously tune the refractive-index sensitivity and to enable measurements of other parameters.

  20. A highly sensitive magnetic biosensor for detection and quantification of anticancer drugs tagged to superparamagnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Wingo, J.; Devkota, J.; Mai, T. T. T.; Nguyen, X. P.; Mukherjee, P.; Srikanth, H.; Phan, M. H.; Vietnam Academy of Science and Technology Collaboration; University of South Florida Team

    2014-03-01

    A precise detection of low concentrations of biomolecules attached to magnetic nanoparticles in complex biological systems is a challenging task and requires biosensors with improved sensitivity. Here, we present a highly sensitive magnetic biosensor based on the magneto-reactance (MX) effect of a Co65Fe4Ni2Si15B14 amorphous ribbon with nanohole-patterned surface for detection and quantification of anticancer drugs (Curcumin) tagged to Fe3O4 nanoparticles. The detection and quantification of Curcumin were assessed by the change in MX of the ribbon subject to varying concentrations of the functionalized Fe3O4 nanoparticles. A high capacity of the MX-based biosensor in quantitative analysis of the nanoparticles was achieved in the range of 0 - 50 ng/ml, beyond which the detection sensitivity (η) remained unchanged. The η of the biosensor reached an extremely high value of 30%, which is about 4-5 times higher than that of a magneto-impedance (MI) based biosensor. This biosensor is well suited for detection of low-concentration magnetic biomarkers in biological systems. This work was supported by was supported by the Florida Cluster for Advanced Smart Sensor Technologies, USAMRMC (Grant # W81XWH-07-1-0708), and the NSF-funded REU program at the USF.

  1. High-Rate Strong-Signal Quantum Cryptography

    NASA Technical Reports Server (NTRS)

    Yuen, Horace P.

    1996-01-01

    Several quantum cryptosystems utilizing different kinds of nonclassical lights, which can accommodate high intensity fields and high data rate, are described. However, they are all sensitive to loss and both the high rate and the strong-signal character rapidly disappear. A squeezed light homodyne detection scheme is proposed which, with present-day technology, leads to more than two orders of magnitude data rate improvement over other current experimental systems for moderate loss.

  2. Comparison between two methodologies for urban drainage decision aid.

    PubMed

    Moura, P M; Baptista, M B; Barraud, S

    2006-01-01

    The objective of the present work is to compare two methodologies based on multicriteria analysis for the evaluation of stormwater systems. The first methodology was developed in Brazil and is based on performance-cost analysis, the second one is ELECTRE III. Both methodologies were applied to a case study. Sensitivity and robustness analyses were then carried out. These analyses demonstrate that both methodologies have equivalent results, and present low sensitivity and high robustness. These results prove that the Brazilian methodology is consistent and can be used safely in order to select a good solution or a small set of good solutions that could be compared with more detailed methods afterwards.

  3. Factorizing the motion sensitivity function into equivalent input noise and calculation efficiency.

    PubMed

    Allard, Rémy; Arleo, Angelo

    2017-01-01

    The photopic motion sensitivity function of the energy-based motion system is band-pass peaking around 8 Hz. Using an external noise paradigm to factorize the sensitivity into equivalent input noise and calculation efficiency, the present study investigated if the variation in photopic motion sensitivity as a function of the temporal frequency is due to a variation of equivalent input noise (e.g., early temporal filtering) or calculation efficiency (ability to select and integrate motion). For various temporal frequencies, contrast thresholds for a direction discrimination task were measured in presence and absence of noise. Up to 15 Hz, the sensitivity variation was mainly due to a variation of equivalent input noise and little variation in calculation efficiency was observed. The sensitivity fall-off at very high temporal frequencies (from 15 to 30 Hz) was due to a combination of a drop of calculation efficiency and a rise of equivalent input noise. A control experiment in which an artificial temporal integration was applied to the stimulus showed that an early temporal filter (generally assumed to affect equivalent input noise, not calculation efficiency) could impair both the calculation efficiency and equivalent input noise at very high temporal frequencies. We conclude that at the photopic luminance intensity tested, the variation of motion sensitivity as a function of the temporal frequency was mainly due to early temporal filtering, not to the ability to select and integrate motion. More specifically, we conclude that photopic motion sensitivity at high temporal frequencies is limited by internal noise occurring after the transduction process (i.e., neural noise), not by quantal noise resulting from the probabilistic absorption of photons by the photoreceptors as previously suggested.

  4. Accurate Filtering of Privacy-Sensitive Information in Raw Genomic Data.

    PubMed

    Decouchant, Jérémie; Fernandes, Maria; Völp, Marcus; Couto, Francisco M; Esteves-Veríssimo, Paulo

    2018-04-13

    Sequencing thousands of human genomes has enabled breakthroughs in many areas, among them precision medicine, the study of rare diseases, and forensics. However, mass collection of such sensitive data entails enormous risks if not protected to the highest standards. In this article, we follow the position and argue that post-alignment privacy is not enough and that data should be automatically protected as early as possible in the genomics workflow, ideally immediately after the data is produced. We show that a previous approach for filtering short reads cannot extend to long reads and present a novel filtering approach that classifies raw genomic data (i.e., whose location and content is not yet determined) into privacy-sensitive (i.e., more affected by a successful privacy attack) and non-privacy-sensitive information. Such a classification allows the fine-grained and automated adjustment of protective measures to mitigate the possible consequences of exposure, in particular when relying on public clouds. We present the first filter that can be indistinctly applied to reads of any length, i.e., making it usable with any recent or future sequencing technologies. The filter is accurate, in the sense that it detects all known sensitive nucleotides except those located in highly variable regions (less than 10 nucleotides remain undetected per genome instead of 100,000 in previous works). It has far less false positives than previously known methods (10% instead of 60%) and can detect sensitive nucleotides despite sequencing errors (86% detected instead of 56% with 2% of mutations). Finally, practical experiments demonstrate high performance, both in terms of throughput and memory consumption. Copyright © 2018. Published by Elsevier Inc.

  5. Aeroallergen Sensitization in Wheezing Children From Rosario, Argentina

    PubMed Central

    Pendino, Patricia; Agüero, Claudio; Cavagnero, Paola; Lopez, Karina; Molinas, Jorge

    2011-01-01

    Background Wheezing is a highly frequent symptom in infants and children. Its major causes are respiratory infections and bronchial asthma. In this context, allergen sensitization plays an important role, and it can be detected by a skin prick test, a safe and effective technique that can be easily performed on any age-group. To assess the prevalence of aeroallergen sensitization in a pediatric population with recurrent episodes of wheezing. Materials and Methods Cross-sectional study that evaluated 100 patients, 50 (50%) girls and 50 (50%) boys, from 6 months to 10 years. These children had consulted frequently at the Allergy and Immunology Division of the Eva Perón School Hospital due to recurrent episodes of wheezing. Skin prick test were performed on all of them and also on 20 healthy children. Results Overall, 58% of the patients presented sensitization to dust mite, 13% to pollen, 9% to epithelium, 8% to fungi, 6% to cockroach, and 1% to soybean hull. Overall, 60% of the patients were positive to at least one of the extracts, and we observed a significant and gradual increase in the frequency of sensitization in older age-groups (P < 0.005). This increase persisted when analyzing separately the dust mite group and the pollen group. None of the cases presented any adverse local or systemic reaction during the procedure or the following 24 hours after the procedure. The 20 individuals in the control group turned out negative when tested. Conclusions This study found high aeroallergen sensitization prevalence in a pediatric population with recurrent episodes of wheezing examined in the Allergy and Immunology Division of the Eva Perón School Hospital, which is in the southern area of the province of Santa Fe in Argentina. PMID:23268433

  6. Predicting suicide attempts with the SAD PERSONS scale: a longitudinal analysis.

    PubMed

    Bolton, James M; Spiwak, Rae; Sareen, Jitender

    2012-06-01

    The SAD PERSONS scale is a widely used risk assessment tool for suicidal behavior despite a paucity of supporting data. The objective of this study was to examine the ability of the scale in predicting suicide attempts. Participants consisted of consecutive referrals (N=4,019) over 2 years (January 1, 2009 to December 31, 2010) to psychiatric services in the emergency departments of the 2 largest tertiary care hospitals in the province of Manitoba, Canada. SAD PERSONS and Modified SAD PERSONS (MSPS) scale scores were recorded for individuals at their index and all subsequent presentations. The 2 main outcome measures in the study included current suicide attempts (at index presentation) and future suicide attempts (within the next 6 months). The ability of the scales to predict suicide attempts was evaluated with logistic regression, sensitivity and specificity analyses, and receiver operating characteristic curves. 566 people presented with suicide attempts (14.1% of the sample). Both SAD PERSONS and MSPS showed poor predictive ability for future suicide attempts. Compared to low risk scores, high risk baseline scores had low sensitivity (19.6% and 40.0%, respectively) and low positive predictive value (5.3% and 7.4%, respectively). SAD PERSONS did not predict suicide attempts better than chance (area under the curve =0.572; 95% confidence interval [CI], 0.51-0.64; P value nonsignificant). Stepwise regression identified 5 original scale items that accounted for the greatest proportion of future suicide attempt variance. High risk scores using this model had high sensitivity (93.5%) and were associated with a 5-fold higher likelihood of future suicide attempt presentation (odds ratio =5.58; 95% CI, 2.24-13.86; P<.001). In their current form, SAD PERSONS and MSPS do not accurately predict future suicide attempts. © Copyright 2012 Physicians Postgraduate Press, Inc.

  7. A sensitivity analysis of process design parameters, commodity prices and robustness on the economics of odour abatement technologies.

    PubMed

    Estrada, José M; Kraakman, N J R Bart; Lebrero, Raquel; Muñoz, Raúl

    2012-01-01

    The sensitivity of the economics of the five most commonly applied odour abatement technologies (biofiltration, biotrickling filtration, activated carbon adsorption, chemical scrubbing and a hybrid technology consisting of a biotrickling filter coupled with carbon adsorption) towards design parameters and commodity prices was evaluated. Besides, the influence of the geographical location on the Net Present Value calculated for a 20 years lifespan (NPV20) of each technology and its robustness towards typical process fluctuations and operational upsets were also assessed. This comparative analysis showed that biological techniques present lower operating costs (up to 6 times) and lower sensitivity than their physical/chemical counterparts, with the packing material being the key parameter affecting their operating costs (40-50% of the total operating costs). The use of recycled or partially treated water (e.g. secondary effluent in wastewater treatment plants) offers an opportunity to significantly reduce costs in biological techniques. Physical/chemical technologies present a high sensitivity towards H2S concentration, which is an important drawback due to the fluctuating nature of malodorous emissions. The geographical analysis evidenced high NPV20 variations around the world for all the technologies evaluated, but despite the differences in wage and price levels, biofiltration and biotrickling filtration are always the most cost-efficient alternatives (NPV20). When, in an economical evaluation, the robustness is as relevant as the overall costs (NPV20), the hybrid technology would move up next to BTF as the most preferred technologies. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Uncooled IR imager with 5-mK NEDT

    NASA Astrophysics Data System (ADS)

    Amantea, Robert; Knoedler, C. M.; Pantuso, Francis P.; Patel, Vipulkumar; Sauer, Donald J.; Tower, John R.

    1997-08-01

    The bi-material concept for room-temperature infrared imaging has the potential of reaching an NE(Delta) T approaching the theoretical limit because of its high responsivity and low noise. The approach, which is 100% compatible with silicon IC foundry processing, utilizes a novel combination of surface micromachining and conventional integrated circuits to produce a bimaterial thermally sensitive element that controls the position of a capacitive plate coupled to the input of a low noise MOS amplifier. This approach can achieve the high sensitivity, the low weight, and the low cost necessary for equipment such as helmet mounted IR viewers and IR rifle sights. The pixel design has the following benefits: (1) an order of magnitude improvement in NE(Delta) T due to extremely high sensitivity and low noise, (2) low cost due to 100% silicon IC compatibility, (3) high image quality and increased yield due to ability to do offset and sensitivity corrections on the imager, pixel-by-pixel; (4) no cryogenic cooler and no high vacuum processing; and (5) commercial applications such as law enforcement, home security, and transportation safety. Two designs are presented. One is a 50 micrometer pixel using silicon nitride as the thermal isolation element that can achieve 5 mK NE(Delta) T; the other is a 29 micrometer pixel using silicon carbide that provides much higher thermal isolation and can achieve 10 mK NE(Delta) T.

  9. Introduction of a hydrolysis probe PCR assay for high-throughput screening of methicillin-resistant Staphylococcus aureus with the ability to include or exclude detection of Staphylococcus argenteus.

    PubMed

    Bogestam, Katja; Vondracek, Martin; Karlsson, Mattias; Fang, Hong; Giske, Christian G

    2018-01-01

    Many countries using sensitive screening methods for detection of carriage of methicillin-resistant Staphylococcus aureus (MRSA) have a sustained low incidence of MRSA infections. For diagnostic laboratories with high sample volumes, MRSA screening requires stability, low maintenance and high performance at a low cost. Herein we designed oligonucleotides for a new nuc targeted hydrolysis probe PCR to replace the standard in-house nuc SybrGreen PCR assay. This new, more time-efficient, PCR assay resulted in a 40% increase in daily sample capacity, with maintained high specificity and sensitivity. The assay was also able to detect Staphylococcus aureus clonal cluster 75 (CC75) lineage strains, recently re-classified as Staphylococcus argenteus, with a sensitivity considerably increased compared to our previous assay. While awaiting consensus if the CC75 lineage of S. aureus should be considered as S. argenteus, and whether methicillin-resistant S. argenteus should be included in the MRSA definition, many diagnostic laboratories need to update their MRSA assay sensitivity/specificity towards this lineage/species. The MRSA screening assay presented in this manuscript is comprised of nuc oligonucleotides separately targeting S. aureus and CC75 lineage strains/S. argenteus, thus providing high user flexibility for the detection of CC75 lineage strains/S. argenteus.

  10. Effect of Hydroxyl Concentration on Chemical Sensitivity of Polyvinyl Alcohol/Carbon-Black Composite Chemiresistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, Robert C.; Patel, Sanjay V.; Yelton, W. Graham

    1999-05-19

    The sensitivity and selectivity of polyvinyl alcohol (PVA) / carbon black composite films have been found to vary depending upon the hydroxylation percentage ("-OH") of the polymer. These chemiresistors made from PVA films whose polymer backbone is 88% hydroxylated (PVA88) have a high sensitivity to water, while chemiresistors made from PVA75 have a higher sensitivity to methanol. The minor differences in polymer composition result in films with different Hildebrand volubility parameters. The relative responses of several different PVA-based chemiresistors to solvents with different volubility parameters are presented. In addition, polyvinyl acetate (PVAC) films with PVA88 are used in an arraymore » to distinguish the responses to methanol-water mixtures.« less

  11. Sensitive periods in affective development: nonlinear maturation of fear learning.

    PubMed

    Hartley, Catherine A; Lee, Francis S

    2015-01-01

    At specific maturational stages, neural circuits enter sensitive periods of heightened plasticity, during which the development of both brain and behavior are highly receptive to particular experiential information. A relatively advanced understanding of the regulatory mechanisms governing the initiation, closure, and reinstatement of sensitive period plasticity has emerged from extensive research examining the development of the visual system. In this article, we discuss a large body of work characterizing the pronounced nonlinear changes in fear learning and extinction that occur from childhood through adulthood, and their underlying neural substrates. We draw upon the model of sensitive period regulation within the visual system, and present burgeoning evidence suggesting that parallel mechanisms may regulate the qualitative changes in fear learning across development.

  12. Sensitive Periods in Affective Development: Nonlinear Maturation of Fear Learning

    PubMed Central

    Hartley, Catherine A; Lee, Francis S

    2015-01-01

    At specific maturational stages, neural circuits enter sensitive periods of heightened plasticity, during which the development of both brain and behavior are highly receptive to particular experiential information. A relatively advanced understanding of the regulatory mechanisms governing the initiation, closure, and reinstatement of sensitive period plasticity has emerged from extensive research examining the development of the visual system. In this article, we discuss a large body of work characterizing the pronounced nonlinear changes in fear learning and extinction that occur from childhood through adulthood, and their underlying neural substrates. We draw upon the model of sensitive period regulation within the visual system, and present burgeoning evidence suggesting that parallel mechanisms may regulate the qualitative changes in fear learning across development. PMID:25035083

  13. Application of artificial neural network to predict clay sensitivity in a high landslide prone area using CPTu data- A case study in Southwest of Sweden

    NASA Astrophysics Data System (ADS)

    Shahri, Abbas; Mousavinaseri, Mahsasadat; Naderi, Shima; Espersson, Maria

    2015-04-01

    Application of Artificial Neural Networks (ANNs) in many areas of engineering, in particular to geotechnical engineering problems such as site characterization has demonstrated some degree of success. The present paper aims to evaluate the feasibility of several various types of ANN models to predict the clay sensitivity of soft clays form piezocone penetration test data (CPTu). To get the aim, a research database of CPTu data of 70 test points around the Göta River near the Lilli Edet in the southwest of Sweden which is a high prone land slide area were collected and considered as input for ANNs. For training algorithms the quick propagation, conjugate gradient descent, quasi-Newton, limited memory quasi-Newton and Levenberg-Marquardt were developed tested and trained using the CPTu data to provide a comparison between the results of field investigation and ANN models to estimate the clay sensitivity. The reason of using the clay sensitivity parameter in this study is due to its relation to landslides in Sweden.A special high sensitive clay namely quick clay is considered as the main responsible for experienced landslides in Sweden which has high sensitivity and prone to slide. The training and testing program was started with 3-2-1 ANN architecture structure. By testing and trying several various architecture structures and changing the hidden layer in order to have a higher output resolution the 3-4-4-3-1 architecture structure for ANN in this study was confirmed. The tested algorithm showed that increasing the hidden layers up to 4 layers in ANN can improve the results and the 3-4-4-3-1 architecture structure ANNs for prediction of clay sensitivity represent reliable and reasonable response. The obtained results showed that the conjugate gradient descent algorithm with R2=0.897 has the best performance among the tested algorithms. Keywords: clay sensitivity, landslide, Artificial Neural Network

  14. Sensitivity to Envelope Interaural Time Differences at High Modulation Rates

    PubMed Central

    Bleeck, Stefan; McAlpine, David

    2015-01-01

    Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor—to the point of discrimination thresholds being unattainable—compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners’ sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered. PMID:26721926

  15. Assessment of the Vibrations Effects Caused by Technical Seismicity Due to the Railway traffic on High-sensitivity Machinery

    NASA Astrophysics Data System (ADS)

    Papán, Daniel; Valašková, Veronika; Demeterová, Katarína

    2016-10-01

    The numerical and experimental approach in structural dynamics problems is more and more current nowadays. This approach is applied and solved in many research and developing institutions of the all the world. Vibrations effect caused by passing trains used in manufacturing facilities can affect the quality of the production activity. This effect is possible to be solved by a numerical or an experimental way. Numerical solution is not so financially and time demanding. The main aim of this article is to focus on just experimental measurement of this problem. In this paper, the case study with measurement due to cramped conditions realized in situ is presented. The case study is located close to railway. The vibration effect caused by passing trains on the high-sensitivity machinery contained in this object were observed. The structure was a high-sensitivity machine that was placed in a construction process. For the measurements, the high-sensitivity standard vibrations equipment was used. The assessments of measurements’ results were performed for the technological conditions and Slovak Standard Criteria. Both of these assessments were divided to amplitude and frequency domain. The amplitude criterion is also divided to peak particle velocity and RMS (Root Mean Square). Frequency domain assessment were realised using the frequency response curves obtained from high-sensitivity machinery manufacturer. The frequency limits are established for each axis of triaxle system. The measurement results can be predicted if the vibration have to be reduced. Measurement implemented in the production hall should obtain materials to determine the seismic loading and response of production machinery caused by technical seismicity.

  16. A Highly Sensitive Two-Dimensional Inclinometer Based on Two Etched Chirped-Fiber-Grating Arrays †

    PubMed Central

    Chang, Hung-Ying; Chang, Yu-Chung; Liu, Wen-Fung

    2017-01-01

    We present a novel two-dimensional fiber-optic inclinometer with high sensitivity by crisscrossing two etched chirped fiber Bragg gratings (CFBG) arrays. Each array is composed of two symmetrically-arranged CFBGs. By etching away most of the claddings of the CFBGs to expose the evanescent wave, the reflection spectra are highly sensitive to the surrounding index change. When we immerse only part of the CFBG in liquid, the effective index difference induces a superposition peak in the refection spectrum. By interrogating the peak wavelengths of the CFBGs, we can deduce the tilt angle and direction simultaneously. The inclinometer has a resolution of 0.003° in tilt angle measurement and 0.00187 rad in tilt direction measurement. Due to the unique sensing mechanism, the sensor is temperature insensitive. This sensor can be useful in long term continuous monitoring of inclination or in real-time feedback control of tilt angles, especially in harsh environments with violent temperature variation. PMID:29244770

  17. Automated High-Speed Video Detection of Small-Scale Explosives Testing

    NASA Astrophysics Data System (ADS)

    Ford, Robert; Guymon, Clint

    2013-06-01

    Small-scale explosives sensitivity test data is used to evaluate hazards of processing, handling, transportation, and storage of energetic materials. Accurate test data is critical to implementation of engineering and administrative controls for personnel safety and asset protection. Operator mischaracterization of reactions during testing contributes to either excessive or inadequate safety protocols. Use of equipment and associated algorithms to aid the operator in reaction determination can significantly reduce operator error. Safety Management Services, Inc. has developed an algorithm to evaluate high-speed video images of sparks from an ESD (Electrostatic Discharge) machine to automatically determine whether or not a reaction has taken place. The algorithm with the high-speed camera is termed GoDetect (patent pending). An operator assisted version for friction and impact testing has also been developed where software is used to quickly process and store video of sensitivity testing. We have used this method for sensitivity testing with multiple pieces of equipment. We present the fundamentals of GoDetect and compare it to other methods used for reaction detection.

  18. A microelectromechanical systems (MEMS) force-displacement transducer for sub-5 nm nanoindentation and adhesion measurements

    NASA Astrophysics Data System (ADS)

    Zhang, Youfeng; Oh, Yunje; Stauffer, Douglas; Polycarpou, Andreas A.

    2018-04-01

    We present a highly sensitive force-displacement transducer capable of performing ultra-shallow nanoindentation and adhesion measurements. The transducer utilizes electrostatic actuation and capacitive sensing combined with microelectromechanical fabrication technologies. Air indentation experiments report a root-mean-square (RMS) force resolution of 1.8 nN and an RMS displacement resolution of 0.019 nm. Nanoindentation experiments on a standard fused quartz sample report a practical RMS force resolution of 5 nN and an RMS displacement resolution of 0.05 nm at sub-10 nm indentation depths, indicating that the system has a very low system noise for indentation experiments. The high sensitivity and low noise enables the transducer to obtain high-resolution nanoindentation data at sub-5 nm contact depths. The sensitive force transducer is used to successfully perform nanoindentation measurements on a 14 nm thin film. Adhesion measurements were also performed, clearly capturing the pull-on and pull-off forces during approach and separation of two contacting surfaces.

  19. Stop Saying That It Is Wrong! Psychophysiological, Cognitive, and Metacognitive Markers of Children’s Sensitivity to Punishment

    PubMed Central

    Gonzalez-Gadea, Maria Luz; Scheres, Anouk; Tobon, Carlos Andres; Damm, Juliane; Baez, Sandra; Huepe, David; Marino, Julian; Marder, Sandra; Manes, Facundo; Abrevaya, Sofia; Ibanez, Agustin

    2015-01-01

    Neurodevelopmental evidence suggests that children’s main decision-making strategy is to avoid options likely to induce punishment. However, the cognitive and affective factors contributing to children’s avoidance to high punishment frequency remain unknown. The present study explored psychophysiological, cognitive, and metacognitive processes associated with sensitivity to punishment frequency. We evaluated 54 participants (between 8 and 15 years old) with a modified Iowa Gambling Task for children (IGT-C) which included options with varying long-term profit and punishment frequencies. Skin conductance responses (SCRs) were recorded during this task. Additionally, we assessed IGT-C metacognitive knowledge, fluid intelligence, and executive functions. Participants exhibited behavioral avoidance and high anticipatory SCRs to options with high frequency of punishment. Moreover, age, IGT-C metacognitive knowledge, and inhibitory control were associated with individual differences in sensitivity to punishment frequency. Our results suggest that children’s preference for infrequently punished decisions is partially explained by psychophysiological signals as well as task complexity and development of cognitive control. PMID:26218584

  20. Stop Saying That It Is Wrong! Psychophysiological, Cognitive, and Metacognitive Markers of Children's Sensitivity to Punishment.

    PubMed

    Gonzalez-Gadea, Maria Luz; Scheres, Anouk; Tobon, Carlos Andres; Damm, Juliane; Baez, Sandra; Huepe, David; Marino, Julian; Marder, Sandra; Manes, Facundo; Abrevaya, Sofia; Ibanez, Agustin

    2015-01-01

    Neurodevelopmental evidence suggests that children's main decision-making strategy is to avoid options likely to induce punishment. However, the cognitive and affective factors contributing to children's avoidance to high punishment frequency remain unknown. The present study explored psychophysiological, cognitive, and metacognitive processes associated with sensitivity to punishment frequency. We evaluated 54 participants (between 8 and 15 years old) with a modified Iowa Gambling Task for children (IGT-C) which included options with varying long-term profit and punishment frequencies. Skin conductance responses (SCRs) were recorded during this task. Additionally, we assessed IGT-C metacognitive knowledge, fluid intelligence, and executive functions. Participants exhibited behavioral avoidance and high anticipatory SCRs to options with high frequency of punishment. Moreover, age, IGT-C metacognitive knowledge, and inhibitory control were associated with individual differences in sensitivity to punishment frequency. Our results suggest that children's preference for infrequently punished decisions is partially explained by psychophysiological signals as well as task complexity and development of cognitive control.

  1. Refractometers for different refractive index range by surface plasmon resonance sensors in multimode optical fibers with different metals

    NASA Astrophysics Data System (ADS)

    Zuppella, P.; Corso, Alain J.; Pelizzo, Maria G.; Cennamo, N.; Zeni, L.

    2016-09-01

    We have realized a plasmonic sensor based on Au/Pd metal bilayer in a multimode plastic optical fiber. This metal bilayer, based on a metal with high imaginary part of the refractive index and gold, shows interesting properties in terms of sensitivity and performances, in different refractive index ranges. The development of highly sensitive platforms for high refractive index detection (higher than 1.38) is interesting for chemical applications based on molecularly imprinted polymer as receptors, while the aqueous medium is the refractive index range of biosensors based on bio-receptors. In this work we have presented an Au/Pd metal bilayer optimized for 1.38-1.42 refractive index range.

  2. Space-Based Diagnosis of Surface Ozone Sensitivity to Anthropogenic Emissions

    NASA Technical Reports Server (NTRS)

    Martin, Randall V.; Fiore, Arlene M.; VanDonkelaar, Aaron

    2004-01-01

    We present a novel capability in satellite remote sensing with implications for air pollution control strategy. We show that the ratio of formaldehyde columns to tropospheric nitrogen dioxide columns is an indicator of the relative sensitivity of surface ozone to emissions of nitrogen oxides (NO(x) = NO + NO2) and volatile organic compounds (VOCs). The diagnosis from these space-based observations is highly consistent with current understanding of surface ozone chemistry based on in situ observations. The satellite-derived ratios indicate that surface ozone is more sensitive to emissions of NO(x) than of VOCs throughout most continental regions of the Northern Hemisphere during summer. Exceptions include Los Angeles and industrial areas of Germany. A seasonal transition occurs in the fall when surface ozone becomes less sensitive to NOx and more sensitive to VOCs.

  3. Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression

    NASA Astrophysics Data System (ADS)

    Wong, Chak

    2005-07-01

    Explosives formulations with Reduced- Sensitivity RDX showed reduced shock sensitivity using NOL Large Scale Gap Test, compared with similar formulations using normal RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light to the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. SIRDX, a form of Reduced- Sensitivity RDX, was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transformed IR (FTIR). The pressure dependence of the Raman mode frequencies of SIRDX was determined and compared with that of normal RDX. The behavior of SIRDX near the pressure at which normal RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph will be presented. Implications to the reduction in sensitivity will be discussed.

  4. Triplex DNA formation-mediated strand displacement reaction for highly sensitive fluorescent detection of melamine.

    PubMed

    Liu, Xiaojuan; Xu, Ningning; Gai, Panpan; Li, Feng

    2018-08-01

    Since melamine is a strong hazard to human health, the development of new methods for highly sensitive detection of melamine is highly desirable. Herein, a novel fluorescent biosensing strategy was designed for sensitive and selective melamine assay based on the recognition ability of abasic (AP) site in triplex towards melamine and signal amplification by Mg 2+ -dependent DNAzyme. In this strategy, the melamine-induced formation of triplex DNA was employed to trigger the strand displacement reaction (SDR). The SDR process converted the specific target recognition into the release and activation of Mg 2+ -dependent DNAzyme, which could catalyze the cleavage of fluorophore/quencher labeled DNA substrate (FQ), resulting in a significantly increased fluorescent signal. Under the optimal conditions, the fluorescent signal has a linear relationship with the logarithm of the melamine concentration in a wide range of 0.005-50 μM. The detection limit was estimated to be 0.9 nM (0.1ppb), which is sufficiently sensitive for practical application. Furthermore, this strategy exhibits high selectivity against other potential interfering substances, and the practical application of this strategy for milk samples reveals that the proposed strategy works well for melamine assay in real samples. Therefore, this strategy presents a new method for the sensitive melamine assay and holds great promise for sensing applications in the environment and the food safety field. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Magnetic field response of doubly clamped magnetoelectric microelectromechanical AlN-FeCo resonators

    NASA Astrophysics Data System (ADS)

    Bennett, S. P.; Baldwin, J. W.; Staruch, M.; Matis, B. R.; LaComb, J.; van't Erve, O. M. J.; Bussmann, K.; Metzler, M.; Gottron, N.; Zappone, W.; LaComb, R.; Finkel, P.

    2017-12-01

    Magnetoelectric (ME) cantilever resonators have been successfully employed as magnetic sensors to measure low magnetic fields; however, high relative resolution enabling magnetometry in high magnetic fields is lacking. Here, we present on-chip silicon based ME microelectromechanical (MEMS) doubly clamped resonators which can be utilized as high sensitivity, low power magnetic sensors. The resonator is a fully suspended thin film ME heterostructure composed of an active magnetoelastic layer (Fe0.3Co0.7), which is strain coupled to a piezoelectric signal/excitation layer (AlN). By controlling uniaxial stress arising from the large magnetoelastic properties of magnetostrictive FeCo, a magnetically driven shift of the resonance frequency of the first fundamental flexural mode is observed. The theoretical intrinsic magnetic noise floor of such sensors reaches a minimum value of 35 p T /√{H z }. This approach shows a magnetic field sensitivity of ˜5 Hz/mT in a bias magnetic field of up to 120 mT. Such sensors have the potential in applications required for enhanced dynamic sensitivity in high-field magnetometry.

  6. Coffee and caffeine improve insulin sensitivity and glucose tolerance in C57BL/6J mice fed a high-fat diet.

    PubMed

    Matsuda, Yuji; Kobayashi, Misato; Yamauchi, Rie; Ojika, Makoto; Hiramitsu, Masanori; Inoue, Takashi; Katagiri, Takao; Murai, Atsushi; Horio, Fumihiko

    2011-01-01

    We have previously demonstrated that coffee and caffeine ameliorated hyperglycemia in spontaneously diabetic KK-A(y) mice. This present study evaluates the antidiabetic effects of coffee and caffeine on high-fat-diet-induced impaired glucose tolerance in C57BL/6J mice. C57BL/6J mice fed a high-fat diet were given regular drinking water (control group), or a 2.5-fold-diluted coffee or caffeine solution (200 mg/L) for 17 weeks. The ingestion of coffee or caffeine improved glucose tolerance, insulin sensitivity, and hyperinsulinemia when compared with mice in the control group. The adipose tissue mRNA levels of inflammatory adipocytokines (MCP-1 and IL-6) and the liver mRNA levels of genes related to fatty acid synthesis were lower in the coffee and caffeine groups than those in the control group. These results suggest that coffee and caffeine exerted an ameliorative effect on high-fat-diet-induced impaired glucose tolerance by improving insulin sensitivity. This effect might be attributable in part to the reduction of inflammatory adipocytokine expression.

  7. Pseudotargeted MS Method for the Sensitive Analysis of Protein Phosphorylation in Protein Complexes.

    PubMed

    Lyu, Jiawen; Wang, Yan; Mao, Jiawei; Yao, Yating; Wang, Shujuan; Zheng, Yong; Ye, Mingliang

    2018-05-15

    In this study, we presented an enrichment-free approach for the sensitive analysis of protein phosphorylation in minute amounts of samples, such as purified protein complexes. This method takes advantage of the high sensitivity of parallel reaction monitoring (PRM). Specifically, low confident phosphopeptides identified from the data-dependent acquisition (DDA) data set were used to build a pseudotargeted list for PRM analysis to allow the identification of additional phosphopeptides with high confidence. The development of this targeted approach is very easy as the same sample and the same LC-system were used for the discovery and the targeted analysis phases. No sample fractionation or enrichment was required for the discovery phase which allowed this method to analyze minute amount of sample. We applied this pseudotargeted MS method to quantitatively examine phosphopeptides in affinity purified endogenous Shc1 protein complexes at four temporal stages of EGF signaling and identified 82 phospho-sites. To our knowledge, this is the highest number of phospho-sites identified from the protein complexes. This pseudotargeted MS method is highly sensitive in the identification of low abundance phosphopeptides and could be a powerful tool to study phosphorylation-regulated assembly of protein complex.

  8. Vibrational Action Spectroscopy of Solids: New Surface-Sensitive Technique

    NASA Astrophysics Data System (ADS)

    Wu, Zongfang; Płucienik, Agata; Feiten, Felix E.; Naschitzki, Matthias; Wachsmann, Walter; Gewinner, Sandy; Schöllkopf, Wieland; Staemmler, Volker; Kuhlenbeck, Helmut; Freund, Hans-Joachim

    2017-09-01

    Vibrational action spectroscopy employing infrared radiation from a free-electron laser has been successfully used for many years to study the vibrational and structural properties of gas phase aggregates. Despite the high sensitivity of this method no relevant studies have yet been conducted for solid sample surfaces. We have set up an experiment for the application of this method to such targets, using infrared light from the free-electron laser of the Fritz Haber Institute. In this Letter, we present first results of this technique with adsorbed argon and neon atoms as messengers. We were able to detect surface-located vibrations of a thin V2O3(0 0 0 1 ) film on Au(111) as well as adsorbate vibrations, demonstrating that this method is highly surface sensitive. We consider that the dominant channel for desorption of the messenger atoms is direct inharmonic vibrational coupling, which is essentially insensitive to subsurface or bulk vibrations. Another channel is thermal desorption due to sample heating by absorption of infrared light. The high surface sensitivity of the nonthermal channel and its insensitivity to subsurface modes makes this technique an ideal tool for the study of surface-located vibrations.

  9. Vibrational Action Spectroscopy of Solids: New Surface-Sensitive Technique.

    PubMed

    Wu, Zongfang; Płucienik, Agata; Feiten, Felix E; Naschitzki, Matthias; Wachsmann, Walter; Gewinner, Sandy; Schöllkopf, Wieland; Staemmler, Volker; Kuhlenbeck, Helmut; Freund, Hans-Joachim

    2017-09-29

    Vibrational action spectroscopy employing infrared radiation from a free-electron laser has been successfully used for many years to study the vibrational and structural properties of gas phase aggregates. Despite the high sensitivity of this method no relevant studies have yet been conducted for solid sample surfaces. We have set up an experiment for the application of this method to such targets, using infrared light from the free-electron laser of the Fritz Haber Institute. In this Letter, we present first results of this technique with adsorbed argon and neon atoms as messengers. We were able to detect surface-located vibrations of a thin V_{2}O_{3}(0001) film on Au(111) as well as adsorbate vibrations, demonstrating that this method is highly surface sensitive. We consider that the dominant channel for desorption of the messenger atoms is direct inharmonic vibrational coupling, which is essentially insensitive to subsurface or bulk vibrations. Another channel is thermal desorption due to sample heating by absorption of infrared light. The high surface sensitivity of the nonthermal channel and its insensitivity to subsurface modes makes this technique an ideal tool for the study of surface-located vibrations.

  10. Threat engagement, disengagement, and sensitivity bias in worry-prone individuals as measured by an emotional go/no-go task.

    PubMed

    Gole, Markus; Köchel, Angelika; Schäfer, Axel; Schienle, Anne

    2012-03-01

    The goal of the present study was to investigate a threat engagement, disengagement, and sensitivity bias in individuals suffering from pathological worry. Twenty participants high in worry proneness and 16 control participants low in worry proneness completed an emotional go/no-go task with worry-related threat words and neutral words. Shorter reaction times (i.e., threat engagement bias), smaller omission error rates (i.e., threat sensitivity bias), and larger commission error rates (i.e., threat disengagement bias) emerged only in the high worry group when worry-related words constituted the go-stimuli and neutral words the no-go stimuli. Also, smaller omission error rates as well as larger commission error rates were observed in the high worry group relative to the low worry group when worry-related go stimuli and neutral no-go stimuli were used. The obtained results await further replication within a generalized anxiety disorder sample. Also, further samples should include men as well. Our data suggest that worry-prone individuals are threat-sensitive, engage more rapidly with aversion, and disengage harder. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Synthesis of molecularly imprinted dye-silica nanocomposites with high selectivity and sensitivity: Fluorescent imprinted sensor for rapid and efficient detection of τ-fluvalinate in vodka.

    PubMed

    Wang, Yunyun; Wang, Jixiang; Cheng, Rujia; Sun, Lin; Dai, Xiaohui; Yan, Yongsheng

    2018-04-01

    An imprinted fluorescent sensor was fabricated based on SiO 2 nanoparticles encapsulated with a molecularly imprinted polymer containing allyl fluorescein. High fluorine cypermethirin as template molecules, methyl methacrylate as functional monomer, and allyl fluorescein as optical materials synthesized a core-shell fluorescent molecular imprinted sensor, which showed a high and rapid sensitivity and selectivity for the detection of τ-fluvalinate. The sensor presented appreciable sensitivity with a limit of 13.251 nM, rapid detection that reached to equilibrium within 3 min, great linear relationship in the relevant concentration range from 0 to 150 nM, and excellent selectivity over structural analogues. In addition, the fluorescent sensor demonstrated desirable regeneration ability (eight cycling operations). The molecularly imprinted polymers ensured specificity, while the fluorescent dyes provided the stabile sensitivity. Finally, an effective application of the sensor was implemented by the detection of τ-fluvalinate in real samples from vodka. The molecularly imprinted fluorescent sensor showed a promising potential in environmental monitoring and food safety. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Wideband optical sensing using pulse interferometry.

    PubMed

    Rosenthal, Amir; Razansky, Daniel; Ntziachristos, Vasilis

    2012-08-13

    Advances in fabrication of high-finesse optical resonators hold promise for the development of miniaturized, ultra-sensitive, wide-band optical sensors, based on resonance-shift detection. Many potential applications are foreseen for such sensors, among them highly sensitive detection in ultrasound and optoacoustic imaging. Traditionally, sensor interrogation is performed by tuning a narrow linewidth laser to the resonance wavelength. Despite the ubiquity of this method, its use has been mostly limited to lab conditions due to its vulnerability to environmental factors and the difficulty of multiplexing - a key factor in imaging applications. In this paper, we develop a new optical-resonator interrogation scheme based on wideband pulse interferometry, potentially capable of achieving high stability against environmental conditions without compromising sensitivity. Additionally, the method can enable multiplexing several sensors. The unique properties of the pulse-interferometry interrogation approach are studied theoretically and experimentally. Methods for noise reduction in the proposed scheme are presented and experimentally demonstrated, while the overall performance is validated for broadband optical detection of ultrasonic fields. The achieved sensitivity is equivalent to the theoretical limit of a 6 MHz narrow-line width laser, which is 40 times higher than what can be usually achieved by incoherent interferometry for the same optical resonator.

  13. Application and Optimization of Stiffness Abruption Structures for Pressure Sensors with High Sensitivity and Anti-Overload Ability

    PubMed Central

    Xu, Tingzhong; Lu, Dejiang; Zhao, Libo; Jiang, Zhuangde; Wang, Hongyan; Guo, Xin; Li, Zhikang; Zhou, Xiangyang; Zhao, Yulong

    2017-01-01

    The influence of diaphragm bending stiffness distribution on the stress concentration characteristics of a pressure sensing chip had been analyzed and discussed systematically. According to the analysis, a novel peninsula-island-based diaphragm structure was presented and applied to two differenet diaphragm shapes as sensing chips for pressure sensors. By well-designed bending stiffness distribution of the diaphragm, the elastic potential energy induced by diaphragm deformation was concentrated above the gap position, which remarkably increased the sensitivity of the sensing chip. An optimization method and the distribution pattern of the peninsula-island based diaphragm structure were also discussed. Two kinds of sensing chips combined with the peninsula-island structures distributing along the side edge and diagonal directions of rectangular diaphragm were fabricated and analyzed. By bonding the sensing chips with anti-overload glass bases, these two sensing chips were demonstrated by testing to achieve not only high sensitivity, but also good anti-overload ability. The experimental results showed that the proposed structures had the potential to measure ultra-low absolute pressures with high sensitivity and good anti-overload ability in an atmospheric environment. PMID:28846599

  14. Perovskite nanoparticle-sensitized Ga 2O 3 nanorod arrays for CO detection at high temperature

    DOE PAGES

    Lin, Hui -Jan; Baltrus, John P.; Gao, Haiyong; ...

    2016-04-04

    Here, noble metal nanoparticles are extensively used for sensitizing metal oxide chemical sensors through the catalytic spillover mechanism. However, due to earth-scarcity and high cost of noble metals, finding replacements presents a great economic benefit. Besides, high temperature and harsh environment sensor applications demand material stability under conditions approaching thermal and chemical stability limits of noble metals. In this study, we employed thermally stable perovskite-type La 0.8Sr 0.2FeO 3 (LSFO) nanoparticle surface decoration on Ga 2O 3 nanorod array gas sensors and discovered an order of magnitude enhanced sensitivity to carbon monoxide at 500 °C. The LSFO nanoparticle catalysts wasmore » of comparable performance to that achieved by Pt nanoparticles, with a much lower weight loading than Pt. Detailed electron microscopy and X-ray photoelectron spectroscopy studies suggested the LSFO nanoparticle sensitization effect is attributed to a spillover-like effect associated with the gas-LSFO-Ga 2O 3 triple-interfaces that spread the negatively charged surface oxygen ions from LSFO nanoparticles surfaces over to β-Ga 2O 3 nanorod surfaces with faster surface CO oxidation reactions.« less

  15. Perovskite Nanoparticle-Sensitized Ga2O3 Nanorod Arrays for CO Detection at High Temperature.

    PubMed

    Lin, Hui-Jan; Baltrus, John P; Gao, Haiyong; Ding, Yong; Nam, Chang-Yong; Ohodnicki, Paul; Gao, Pu-Xian

    2016-04-13

    Noble metal nanoparticles are extensively used for sensitizing metal oxide chemical sensors through the catalytic spillover mechanism. However, due to earth-scarcity and high cost of noble metals, finding replacements presents a great economic benefit. Besides, high temperature and harsh environment sensor applications demand material stability under conditions approaching thermal and chemical stability limits of noble metals. In this study, we employed thermally stable perovskite-type La(0.8)Sr(0.2)FeO3 (LSFO) nanoparticle surface decoration on Ga2O3 nanorod array gas sensors and discovered an order of magnitude enhanced sensitivity to carbon monoxide at 500 °C. The LSFO nanoparticle catalysts was of comparable performance to that achieved by Pt nanoparticles, with a much lower weight loading than Pt. Detailed electron microscopy and X-ray photoelectron spectroscopy studies suggested the LSFO nanoparticle sensitization effect is attributed to a spillover-like effect associated with the gas-LSFO-Ga2O3 triple-interfaces that spread the negatively charged surface oxygen ions from LSFO nanoparticles surfaces over to β-Ga2O3 nanorod surfaces with faster surface CO oxidation reactions.

  16. Engineering the bioelectrochemical interface using functional nanomaterials and microchip technique toward sensitive and portable electrochemical biosensors.

    PubMed

    Jia, Xiaofang; Dong, Shaojun; Wang, Erkang

    2016-02-15

    Electrochemical biosensors have played active roles at the forefront of bioanalysis because they have the potential to achieve sensitive, specific and low-cost detection of biomolecules and many others. Engineering the electrochemical sensing interface with functional nanomaterials leads to novel electrochemical biosensors with improved performances in terms of sensitivity, selectivity, stability and simplicity. Functional nanomaterials possess good conductivity, catalytic activity, biocompatibility and high surface area. Coupled with bio-recognition elements, these features can amplify signal transduction and biorecognition events, resulting in highly sensitive biosensing. Additionally, microfluidic electrochemical biosensors have attracted considerable attention on account of their miniature, portable and low-cost systems as well as high fabrication throughput and ease of scaleup. For example, electrochemical enzymetic biosensors and aptamer biosensors (aptasensors) based on the integrated microchip can be used for portable point-of-care diagnostics and environmental monitoring. This review is a summary of our recent progress in the field of electrochemical biosensors, including aptasensors, cytosensors, enzymatic biosensors and self-powered biosensors based on biofuel cells. We presented the advantages that functional nanomaterials and microfluidic chip technology bring to the electrochemical biosensors, together with future prospects and possible challenges. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Semi-continuous ultrasonic sounding and changes of ultrasonic signal characteristics as a sensitive tool for the evaluation of ongoing microstructural changes of experimental mortar bars tested for their ASR potential.

    PubMed

    Lokajíček, T; Kuchařová, A; Petružálek, M; Šachlová, Š; Svitek, T; Přikryl, R

    2016-09-01

    Semi-continuous ultrasonic sounding of experimental mortar bars used in the accelerated alkali silica reactivity laboratory test (ASTM C1260) is proposed as a supplementary measurement technique providing data that are highly sensitive to minor changes in the microstructure of hardening/deteriorating concrete mixture. A newly designed, patent pending, heating chamber was constructed allowing ultrasonic sounding of mortar bars, stored in accelerating solution without necessity to remove the test specimens from the bath during the measurement. Subsequent automatic data analysis of recorded ultrasonic signals proved their high correlation to the measured length changes (expansion) and their high sensitivity to microstructural changes. The changes of P-wave velocity, and of the energy, amplitude, and frequency of ultrasonic signal, were in the range of 10-80%, compared to 0.51% change of the length. Results presented in this study thus show that ultrasonic sounding seems to be more sensitive to microstructural changes due to ongoing deterioration of concrete microstructure by alkali-silica reaction than the dimensional changes. Copyright © 2016. Published by Elsevier B.V.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Lijuan; Gonder, Jeff; Burton, Evan

    This study evaluates the costs and benefits associated with the use of a plug-in hybrid electric bus and determines the cost effectiveness relative to a conventional bus and a hybrid electric bus. A sensitivity sweep analysis was performed over a number of a different battery sizes, charging powers, and charging stations. The net present value was calculated for each vehicle design and provided the basis for the design evaluation. In all cases, given present day economic assumptions, the conventional bus achieved the lowest net present value while the optimal plug-in hybrid electric bus scenario reached lower lifetime costs than themore » hybrid electric bus. The study also performed parameter sensitivity analysis under low market potential assumptions and high market potential assumptions. The net present value of plug-in hybrid electric bus is close to that of conventional bus.« less

  19. Development and characterization of silicone embedded distributed piezoelectric sensors for contact detection

    NASA Astrophysics Data System (ADS)

    Acer, Merve; Salerno, Marco; Agbeviade, Kossi; Paik, Jamie

    2015-07-01

    Tactile sensing transfers complex interactive information in a most intuitive sense. Such a populated set of data from the environment and human interactions necessitates various degrees of information from both modular and distributed areas. A sensor design that could provide such types of feedback becomes challenging when the target component has a nonuniform, agile, high resolution, and soft surface. This paper presents an innovative methodology for the manufacture of novel soft sensors that have a high resolution sensing array due to the sensitivity of ceramic piezoelectric (PZT) elements, while uncommonly matched with the high stretchability of the soft substrate and electrode design. Further, they have a low profile and their transfer function is easy to tune by changing the material and thickness of the soft substrate in which the PZTs are embedded. In this manuscript, we present experimental results of the soft sensor prototypes: PZTs arranged in a four by two array form, measuring 1.5-2.3 mm in thickness, with the sensitivity in the range of 0.07-0.12 of the normalized signal change per unit force. We have conducted extensive tests under dynamic loading conditions that include impact, step and cyclic. The presented prototype's mechanical and functional capacities are promising for applications in biomedical systems where soft, wearable and high precision sensors are needed.

  20. Concept Study of Optical Configurations for High-Frequency Telescope for LiteBIRD

    NASA Astrophysics Data System (ADS)

    Hasebe, T.; Kashima, S.; Ade, P. A. R.; Akiba, Y.; Alonso, D.; Arnold, K.; Aumont, J.; Baccigalupi, C.; Barron, D.; Basak, S.; Beckman, S.; Borrill, J.; Boulanger, F.; Bucher, M.; Calabrese, E.; Chinone, Y.; Cho, H.-M.; Cukierman, A.; Curtis, D. W.; de Haan, T.; Dobbs, M.; Dominjon, A.; Dotani, T.; Duband, L.; Ducout, A.; Dunkley, J.; Duval, J. M.; Elleflot, T.; Eriksen, H. K.; Errard, J.; Fischer, J.; Fujino, T.; Funaki, T.; Fuskeland, U.; Ganga, K.; Goeckner-Wald, N.; Grain, J.; Halverson, N. W.; Hamada, T.; Hasegawa, M.; Hattori, K.; Hattori, M.; Hayes, L.; Hazumi, M.; Hidehira, N.; Hill, C. A.; Hilton, G.; Hubmayr, J.; Ichiki, K.; Iida, T.; Imada, H.; Inoue, M.; Inoue, Y.; Irwin, K. D.; Ishino, H.; Jeong, O.; Kanai, H.; Kaneko, D.; Katayama, N.; Kawasaki, T.; Kernasovskiy, S. A.; Keskitalo, R.; Kibayashi, A.; Kida, Y.; Kimura, K.; Kisner, T.; Kohri, K.; Komatsu, E.; Komatsu, K.; Kuo, C. L.; Kurinsky, N. A.; Kusaka, A.; Lazarian, A.; Lee, A. T.; Li, D.; Linder, E.; Maffei, B.; Mangilli, A.; Maki, M.; Matsumura, T.; Matsuura, S.; Meilhan, D.; Mima, S.; Minami, Y.; Mitsuda, K.; Montier, L.; Nagai, M.; Nagasaki, T.; Nagata, R.; Nakajima, M.; Nakamura, S.; Namikawa, T.; Naruse, M.; Nishino, H.; Nitta, T.; Noguchi, T.; Ogawa, H.; Oguri, S.; Okada, N.; Okamoto, A.; Okamura, T.; Otani, C.; Patanchon, G.; Pisano, G.; Rebeiz, G.; Remazeilles, M.; Richards, P. L.; Sakai, S.; Sakurai, Y.; Sato, Y.; Sato, N.; Sawada, M.; Segawa, Y.; Sekimoto, Y.; Seljak, U.; Sherwin, B. D.; Shimizu, T.; Shinozaki, K.; Stompor, R.; Sugai, H.; Sugita, H.; Suzuki, A.; Suzuki, J.; Tajima, O.; Takada, S.; Takaku, R.; Takakura, S.; Takatori, S.; Tanabe, D.; Taylor, E.; Thompson, K. L.; Thorne, B.; Tomaru, T.; Tomida, T.; Tomita, N.; Tristram, M.; Tucker, C.; Turin, P.; Tsujimoto, M.; Uozumi, S.; Utsunomiya, S.; Uzawa, Y.; Vansyngel, F.; Wehus, I. K.; Westbrook, B.; Willer, M.; Whitehorn, N.; Yamada, Y.; Yamamoto, R.; Yamasaki, N.; Yamashita, T.; Yoshida, M.

    2018-05-01

    The high-frequency telescope for LiteBIRD is designed with refractive and reflective optics. In order to improve sensitivity, this paper suggests the new optical configurations of the HFT which have approximately 7 times larger focal planes than that of the original design. The sensitivities of both the designs are compared, and the requirement of anti-reflection (AR) coating on the lens for the refractive option is derived. We also present the simulation result of a sub-wavelength AR structure on both surfaces of silicon, which shows a band-averaged reflection of 1.1-3.2% at 101-448 GHz.

  1. A Novel Offset Cancellation Based on Parasitic-Insensitive Switched-Capacitor Sensing Circuit for the Out-of-Plane Single-Gimbaled Decoupled CMOS-MEMS Gyroscope

    PubMed Central

    Chang, Ming-Hui; Huang, Han-Pang

    2013-01-01

    This paper presents a novel parasitic-insensitive switched-capacitor (PISC) sensing circuit design in order to obtain high sensitivity and ultra linearity and reduce the parasitic effect for the out-of-plane single-gimbaled decoupled CMOS-MEMS gyroscope (SGDG). According to the simulation results, the proposed PISC circuit has better sensitivity and high linearity in a wide dynamic range. Experimental results also show a better performance. In addition, the PISC circuit can use signal processing to cancel the offset and noise. Thus, this circuit is very suitable for gyroscope measurement. PMID:23493122

  2. Investigation of low-loss spectra and near-edge fine structure of polymers by PEELS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heckmann, W.

    Transmission electron microscopy has changed from a purely imaging method to an analytical method. This has been facilitated particularly by equipping electron microscopes with energy filters and with parallel electron energy loss spectrometers (PEELS). Because of their relatively high energy resolution (1 to 2 eV) they provide information not only on the elements present but also on the type of bonds between the molecular groups. Polymers are radiation sensitive and the molecular bonds change as the spectrum is being recorded. This can be observed with PEEL spectrometers that are able to record spectra with high sensitivity and in rapid succession.

  3. Sensing analysis based on tunable Fano resonance in terahertz graphene-layered metamaterials

    NASA Astrophysics Data System (ADS)

    Xu, Hui; Zhao, Mingzhuo; Chen, Zhiquan; Zheng, Mingfei; Xiong, Cuixiu; Zhang, Baihui; Li, Hongjian

    2018-05-01

    We theoretically investigate the sensing characteristics based on tunable Fano resonance in terahertz graphene-layered metamaterials. A Fano phenomenon comes from destructive interference in a narrow frequency range, and it can lead to a high figure of merit of ˜9786. A simple model for sensitivity is presented, and the sensitivity can reach up to 7885 nm/RIU. Besides, the Fano peak becomes more and more unobvious as symmetry breaking slowly recovers. We use an appropriate theoretical theory to explain the generation of Fano phenomena. Our proposed structure and investigation may pave the way for fundamental research of nanosensor applications and designs in highly integrated optical circuits.

  4. Graphene Field Effect Transistor for Radiation Detection

    NASA Technical Reports Server (NTRS)

    Li, Mary J. (Inventor); Chen, Zhihong (Inventor)

    2016-01-01

    The present invention relates to a graphene field effect transistor-based radiation sensor for use in a variety of radiation detection applications, including manned spaceflight missions. The sensing mechanism of the radiation sensor is based on the high sensitivity of graphene in the local change of electric field that can result from the interaction of ionizing radiation with a gated undoped silicon absorber serving as the supporting substrate in the graphene field effect transistor. The radiation sensor has low power and high sensitivity, a flexible structure, and a wide temperature range, and can be used in a variety of applications, particularly in space missions for human exploration.

  5. [COMPARATIVE SENSITIVITY OF CHOLINESTERASES IN VERTEBRATES AND INVERTEBRATES TO HIGHLY SPECIFIC ORGANOPHOSPHORUS INHIBITORS DIISOPROPYL FLUOROPHOSPHATE (DFP) AND (2-ETHOXYMETHYL PHOSPHORYL THIOETHYL) ETHYL (METHYL) SULPHONIUM SULPHOMETHYLAT (GD-42)].

    PubMed

    Basova, N E; Kormilitsyn, B N; Perchenok, A Yu; Rozengart, E V; Saakov, V S; Suvorov, A A

    2015-01-01

    The review presents data on comparative reactivity of 68 cholinesterase preparation from various organs and tissues in a number of vertebrates and invertebrates based on sensitivity to two highly specific and most studied organophosphorus inhibitors--diisopropyl fluorophosphates (DFP) and (2-ethoxymethyl phosphoryl thioethyl) ethyl (methyl) sulphonium sulphomethylat (GD-42). Analysis of these data suggests a great diversity in enzymologic characteristics of cholinesterase preparation in representatives of vertebrates and invertebrates, this variety observed even for closely related enzymes in animals of almost the same level of development.

  6. WASH and gender in health care facilities: The uncharted territory.

    PubMed

    Kohler, Petra; Renggli, Samuel; Lüthi, Christoph

    2017-11-08

    Health care facilities in low- and middle-income countries are high-risk settings, and face special challenges to achieving sustainable water, sanitation, and hygiene (WASH) services. Our applied interdisciplinary research conducted in India and Uganda analyzed six dimensions of WASH services in selected health care facilities, including menstrual hygiene management. To be effective, WASH monitoring strategies in health care facilities must include gender sensitive measures. We present a novel strategy, showing that applied gender sensitive multitool assessments are highly productive in assessments of WASH services and facilities from user and provider perspectives. We discuss its potential for applications at scale and as an area of future research.

  7. Edge effects in composites by moire interferometry

    NASA Technical Reports Server (NTRS)

    Czarnek, R.; Post, D.; Herakovich, C.

    1983-01-01

    The very high sensitivity of moire interferometry has permitted the present edge effect experiments to be conducted at a low average stress and strain level, assuring linear and elastic behavior in the composite material samples tested. Sensitivity corresponding to 2450 line/mm moire was achieved with a 0.408 micron/fringe. Simultaneous observations of the specimen face and edge displacement fields showed good fringe definition despite the 1-mm thickness of the specimens and the high gradients, and it is noted that the use of a carrier pattern and optical filtering was effective in even these conditions. Edge effects and dramatic displacement gradients were confirmed in angle-ply composite laminates.

  8. Emotional expression recognition and attribution bias among sexual and violent offenders: a signal detection analysis

    PubMed Central

    Gillespie, Steven M.; Rotshtein, Pia; Satherley, Rose-Marie; Beech, Anthony R.; Mitchell, Ian J.

    2015-01-01

    Research with violent offenders has consistently shown impaired recognition of other’s facial expressions of emotion. However, the extent to which similar problems can be observed among sexual offenders remains unknown. Using a computerized task, we presented sexual and violent offenders, and non-offenders, with male and female expressions of anger, disgust, fear, happiness, sadness, and surprise, morphed with neutral expressions at varying levels of intensity (10, 55, and 90% expressive). Based on signal detection theory, we used hit rates and false alarms to calculate the sensitivity index d-prime (d′) and criterion (c) for each emotional expression. Overall, sexual offenders showed reduced sensitivity to emotional expressions across intensity, sex, and type of expression, compared with non-offenders, while both sexual and violent offenders showed particular reduced sensitivity to fearful expressions. We also observed specific effects for high (90%) intensity female faces, with sexual offenders showing reduced sensitivity to anger compared with non-offenders and violent offenders, and reduced sensitivity to disgust compared with non-offenders. Furthermore, both sexual and violent offenders showed impaired sensitivity to high intensity female fearful expressions compared with non-offenders. Violent offenders also showed a higher criterion for classifying moderate and high intensity male expressions as fearful, indicative of a more conservative response style, compared with angry, happy, or sad. These results suggest that both types of offender show problems in emotion recognition, and may have implications for understanding the inhibition of violent and sexually violent behaviors. PMID:26029137

  9. Emotional expression recognition and attribution bias among sexual and violent offenders: a signal detection analysis.

    PubMed

    Gillespie, Steven M; Rotshtein, Pia; Satherley, Rose-Marie; Beech, Anthony R; Mitchell, Ian J

    2015-01-01

    Research with violent offenders has consistently shown impaired recognition of other's facial expressions of emotion. However, the extent to which similar problems can be observed among sexual offenders remains unknown. Using a computerized task, we presented sexual and violent offenders, and non-offenders, with male and female expressions of anger, disgust, fear, happiness, sadness, and surprise, morphed with neutral expressions at varying levels of intensity (10, 55, and 90% expressive). Based on signal detection theory, we used hit rates and false alarms to calculate the sensitivity index d-prime (d') and criterion (c) for each emotional expression. Overall, sexual offenders showed reduced sensitivity to emotional expressions across intensity, sex, and type of expression, compared with non-offenders, while both sexual and violent offenders showed particular reduced sensitivity to fearful expressions. We also observed specific effects for high (90%) intensity female faces, with sexual offenders showing reduced sensitivity to anger compared with non-offenders and violent offenders, and reduced sensitivity to disgust compared with non-offenders. Furthermore, both sexual and violent offenders showed impaired sensitivity to high intensity female fearful expressions compared with non-offenders. Violent offenders also showed a higher criterion for classifying moderate and high intensity male expressions as fearful, indicative of a more conservative response style, compared with angry, happy, or sad. These results suggest that both types of offender show problems in emotion recognition, and may have implications for understanding the inhibition of violent and sexually violent behaviors.

  10. Alterations of the Lipid Metabolome in Dairy Cows Experiencing Excessive Lipolysis Early Postpartum

    PubMed Central

    Humer, Elke; Khol-Parisini, Annabella; Metzler-Zebeli, Barbara U.; Gruber, Leonhard; Zebeli, Qendrim

    2016-01-01

    A decrease in insulin sensitivity enhances adipose tissue lipolysis helping early lactation cows counteracting their energy deficit. However, excessive lipolysis poses serious health risks for cows, and its underlying mechanisms are not clearly understood. The present study used targeted ESI-LC-MS/MS-based metabolomics and indirect insulin sensitivity measurements to evaluate metabolic alterations in the serum of dairy cows of various parities experiencing variable lipolysis early postpartum. Thirty (12 primiparous and 18 multiparous) cows of Holstein Friesian and Simmental breeds, fed the same diet and kept under the same management conditions, were sampled at d 21 postpartum and classified as low (n = 10), medium (n = 8), and high (n = 12) lipolysis groups, based on serum concentration of nonesterified fatty acids. Overall, excessive lipolysis in the high group came along with impaired estimated insulin sensitivity and characteristic shifts in acylcarnitine, sphingomyelin, phosphatidylcholine and lysophospholipid metabolome profiles compared to the low group. From the detected phosphatidylcholines mainly those with diacyl-residues showed differences among lipolysis groups. Furthermore, more than half of the detected sphingomyelins were increased in cows experiencing high lipomobilization. Additionally, strong differences in serum acylcarnitines were noticed among lipolysis groups. The study suggests an altered serum phospholipidome in dairy cows associated with an increase in certain long-chain sphingomyelins and the progression of disturbed insulin function. In conclusion, the present study revealed 37 key metabolites as part of alterations in the synthesis or breakdown of sphingolipids and phospholipids associated with lowered estimated insulin sensitivity and excessive lipolysis in early-lactating cows. PMID:27383746

  11. Alterations of the Lipid Metabolome in Dairy Cows Experiencing Excessive Lipolysis Early Postpartum.

    PubMed

    Humer, Elke; Khol-Parisini, Annabella; Metzler-Zebeli, Barbara U; Gruber, Leonhard; Zebeli, Qendrim

    2016-01-01

    A decrease in insulin sensitivity enhances adipose tissue lipolysis helping early lactation cows counteracting their energy deficit. However, excessive lipolysis poses serious health risks for cows, and its underlying mechanisms are not clearly understood. The present study used targeted ESI-LC-MS/MS-based metabolomics and indirect insulin sensitivity measurements to evaluate metabolic alterations in the serum of dairy cows of various parities experiencing variable lipolysis early postpartum. Thirty (12 primiparous and 18 multiparous) cows of Holstein Friesian and Simmental breeds, fed the same diet and kept under the same management conditions, were sampled at d 21 postpartum and classified as low (n = 10), medium (n = 8), and high (n = 12) lipolysis groups, based on serum concentration of nonesterified fatty acids. Overall, excessive lipolysis in the high group came along with impaired estimated insulin sensitivity and characteristic shifts in acylcarnitine, sphingomyelin, phosphatidylcholine and lysophospholipid metabolome profiles compared to the low group. From the detected phosphatidylcholines mainly those with diacyl-residues showed differences among lipolysis groups. Furthermore, more than half of the detected sphingomyelins were increased in cows experiencing high lipomobilization. Additionally, strong differences in serum acylcarnitines were noticed among lipolysis groups. The study suggests an altered serum phospholipidome in dairy cows associated with an increase in certain long-chain sphingomyelins and the progression of disturbed insulin function. In conclusion, the present study revealed 37 key metabolites as part of alterations in the synthesis or breakdown of sphingolipids and phospholipids associated with lowered estimated insulin sensitivity and excessive lipolysis in early-lactating cows.

  12. Photodetector having high speed and sensitivity

    DOEpatents

    Morse, Jeffrey D.; Mariella, Jr., Raymond P.

    1991-01-01

    The present invention provides a photodetector having an advantageous combination of sensitivity and speed; it has a high sensitivity while retaining high speed. In a preferred embodiment, visible light is detected, but in some embodiments, x-rays can be detected, and in other embodiments infrared can be detected. The present invention comprises a photodetector having an active layer, and a recombination layer. The active layer has a surface exposed to light to be detected, and comprises a semiconductor, having a bandgap graded so that carriers formed due to interaction of the active layer with the incident radiation tend to be swept away from the exposed surface. The graded semiconductor material in the active layer preferably comprises Al.sub.1-x Ga.sub.x As. An additional sub-layer of graded In.sub.1-y Ga.sub.y As may be included between the Al.sub.1-x Ga.sub.x As layer and the recombination layer. The recombination layer comprises a semiconductor material having a short recombination time such as a defective GaAs layer grown in a low temperature process. The recombination layer is positioned adjacent to the active layer so that carriers from the active layer tend to be swept into the recombination layer. In an embodiment, the photodetector may comprise one or more additional layers stacked below the active and recombination layers. These additional layers may include another active layer and another recombination layer to absorb radiation not absorbed while passing through the first layers. A photodetector having a stacked configuration may have enhanced sensitivity and responsiveness at selected wavelengths such as infrared.

  13. An intraoperative spectroscopic imaging system for quantification of Protoporphyrin IX during glioma surgery (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Angulo-Rodríguez, Leticia M.; Laurence, Audrey; Jermyn, Michael; Sheehy, Guillaume; Sibai, Mira; Petrecca, Kevin; Roberts, David W.; Paulsen, Keith D.; Wilson, Brian C.; Leblond, Frédéric

    2016-03-01

    Cancer tissue often remains after brain tumor resection due to the inability to detect the full extent of cancer during surgery, particularly near tumor boundaries. Commercial systems are available for intra-operative real-time aminolevulenic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence imaging. These are standard white-light neurosurgical microscopes adapted with optical components for fluorescence excitation and detection. However, these instruments lack sensitivity and specificity, which limits the ability to detect low levels of PpIX and distinguish it from tissue auto-fluorescence. Current systems also cannot provide repeatable and un-biased quantitative fluorophore concentration values because of the unknown and highly variable light attenuation by tissue. We present a highly sensitive spectroscopic fluorescence imaging system that is seamlessly integrated onto a neurosurgical microscope. Hardware and software were developed to achieve through-microscope spatially-modulated illumination for 3D profilometry and to use this information to extract tissue optical properties to correct for the effects of tissue light attenuation. This gives pixel-by-pixel quantified fluorescence values and improves detection of low PpIX concentrations. This is achieved using a high-sensitivity Electron Multiplying Charge Coupled Device (EMCCD) with a Liquid Crystal Tunable Filter (LCTF) whereby spectral bands are acquired sequentially; and a snapshot camera system with simultaneous acquisition of all bands is used for profilometry and optical property recovery. Sensitivity and specificity to PpIX is demonstrated using brain tissue phantoms and intraoperative human data acquired in an on-going clinical study using PpIX fluorescence to guide glioma resection.

  14. Pharmacological effects of ethanol on ingestive behavior of the preweanling rat

    PubMed Central

    Kozlov, Andrey P.; Nizhnikov, Michael E.; Varlinskaya, Elena I.; Spear, Norman E.

    2009-01-01

    The present study was designed to test the hypothesis that sensitivity of ingestive behavior of infant rat to the pharmacological effects of ethanol changes between postnatal (P) days 9 and 12. The intake of 0.1% saccharin and water, general motor activity, and myoclonic twitching activity were assessed following administration of three doses of ethanol (0, 0.25, 0.5g/kg) while fluids were free available to the animals. The 0.5g/kg dose of ethanol attenuated saccharin intake in P9 pups and enhanced saccharin intake in P12 rats. On P12 some sex-related differences emerged at 0.5g/kg of ethanol, with saccharin intake being higher in females than in their male counterparts. Taste reactivity probe revealed that 0.5 g/kg of ethanol increased taste responsiveness to saccharin on P12 but only to infusions presented at a high rate. The results of the present study indicate that ontogenetic changes in sensitivity to the effects of ethanol on ingestive behavior occur during the second postnatal week, with P9 animals being more sensitive to the inhibitory (sedative) effects on saccharin intake and P12 rats being more sensitive to the stimulatory effects of ethanol. We suggest that acute ethanol enhanced saccharin intake via sensitization of oral response to appetitive taste stimulation. PMID:19549546

  15. A novel diagnostic protocol to identify patients suitable for discharge after a single high-sensitivity troponin

    PubMed Central

    Carlton, Edward W; Cullen, Louise; Than, Martin; Gamble, James; Khattab, Ahmed; Greaves, Kim

    2015-01-01

    Objective To establish whether a novel accelerated diagnostic protocol (ADP) for suspected acute coronary syndrome (ACS) could successfully identify low-risk patients suitable for discharge after a single high-sensitivity troponin T (hs-cTnT) taken at presentation to the emergency department. We also compared the diagnostic accuracy of this ADP with strategies using initial undetectable hs-cTnT. Methods This prospective observational study evaluated the ability of the Triage Rule-out Using high-Sensitivity Troponin (TRUST) ADP to identify low-risk patients with suspected ACS. The ADP incorporated a single presentation hs-cTnT of <14 ng/L, a non-ischaemic ECG and a modified Goldman risk score. Diagnostic performance of the ADP was compared with the detection limit cut-offs of hs-cTnT (<5 ng/L and <3 ng/L). The primary end point was fatal/non-fatal acute myocardial infarction (AMI) within 30 days. Results 960 participants were recruited, mean age 58.0 years, 80 (8.3%) had an AMI. The TRUST ADP classified 382 (39.8%) as low-risk with a sensitivity for identifying AMI of 98.8% (95% CI 92.5% to 99.9%). hs-cTnT detection limits (<5 ng/L and <3 ng/L) had a sensitivity of 100% (94.3 to 100) and 100% (94.4 to 100), respectively. The TRUST ADP identified more patients suitable for early discharge at 39.8% vs 29.3% (<5 ng/L) and 7.9% (<3 ng/L) (p<0.001) with a lower false-positive rate for AMI detection; specificity 43.3% (95% CI 42.7% to 43.4%) vs 32.0% (95% CI 31.5% to 32.0%) and 8.6% (95% CI 8.1% to 8.6%), respectively. Conclusions The TRUST ADP, which incorporates structured risk-assessment and a single presentation hs-cTnT blood draw, has potential to allow early discharge in 40% of patients with suspected ACS and has greater clinical utility than undetectable hs-cTnT strategies. Trial registration number ISRCTN No. 21109279. PMID:25691511

  16. High-resolution high-sensitivity elemental imaging by secondary ion mass spectrometry: from traditional 2D and 3D imaging to correlative microscopy

    NASA Astrophysics Data System (ADS)

    Wirtz, T.; Philipp, P.; Audinot, J.-N.; Dowsett, D.; Eswara, S.

    2015-10-01

    Secondary ion mass spectrometry (SIMS) constitutes an extremely sensitive technique for imaging surfaces in 2D and 3D. Apart from its excellent sensitivity and high lateral resolution (50 nm on state-of-the-art SIMS instruments), advantages of SIMS include high dynamic range and the ability to differentiate between isotopes. This paper first reviews the underlying principles of SIMS as well as the performance and applications of 2D and 3D SIMS elemental imaging. The prospects for further improving the capabilities of SIMS imaging are discussed. The lateral resolution in SIMS imaging when using the microprobe mode is limited by (i) the ion probe size, which is dependent on the brightness of the primary ion source, the quality of the optics of the primary ion column and the electric fields in the near sample region used to extract secondary ions; (ii) the sensitivity of the analysis as a reasonable secondary ion signal, which must be detected from very tiny voxel sizes and thus from a very limited number of sputtered atoms; and (iii) the physical dimensions of the collision cascade determining the origin of the sputtered ions with respect to the impact site of the incident primary ion probe. One interesting prospect is the use of SIMS-based correlative microscopy. In this approach SIMS is combined with various high-resolution microscopy techniques, so that elemental/chemical information at the highest sensitivity can be obtained with SIMS, while excellent spatial resolution is provided by overlaying the SIMS images with high-resolution images obtained by these microscopy techniques. Examples of this approach are given by presenting in situ combinations of SIMS with transmission electron microscopy (TEM), helium ion microscopy (HIM) and scanning probe microscopy (SPM).

  17. Sensitivity of six subantarctic marine invertebrates to common metal contaminants.

    PubMed

    Holan, Jessica R; King, Catherine K; Davis, Andrew R

    2016-09-01

    A long history of anthropogenic activities in the relatively pristine subantarctic has resulted in areas of accumulated waste and contaminants. Sensitivities to metals of subantarctic and Antarctic species may contrast with related species from temperate and tropical areas because of the unique characteristics of polar biota. In addition, response to contaminants may be delayed, and hence longer exposure periods may be required in toxicity tests with polar species. In the present study, the sensitivity of 6 common subantarctic marine invertebrates to copper, zinc, and cadmium contaminants was determined. Large variations in sensitivities, both between species and between metals within species, were found. The bivalve Gaimardia trapesina and the copepod Harpacticus sp. were the most sensitive to copper, with 7-d median lethal concentration (LC50) values for both species ranging between 28 μg/L and 62 μg/L, whereas the copepod Tigriopus angulatus was the most tolerant of copper (7-d Cu LC50 1560 μg/L). Sensitivity to zinc varied by approximately 1 order of magnitude between species (7-d LC50: 329-3057 μg/L). Sensitivity to cadmium also varied considerably between species, with 7-d LC50 values ranging from 1612 μg/L to >4383 μg/L. The present study is the first to report the sensitivity of subantarctic marine invertebrate to metals, and contributes significantly to the understanding of latitudinal gradients in the sensitivity of biota to metals. Although sensitivity is highly variable between species, in a global comparison of copepod data, it appears that species from higher latitudes may be more sensitive to copper. Environ Toxicol Chem 2016;35:2245-2251. © 2016 SETAC. © 2016 SETAC.

  18. Prostate Cancer Information Available in Health-Care Provider Offices: An Analysis of Content, Readability, and Cultural Sensitivity.

    PubMed

    Choi, Seul Ki; Seel, Jessica S; Yelton, Brooks; Steck, Susan E; McCormick, Douglas P; Payne, Johnny; Minter, Anthony; Deutchki, Elizabeth K; Hébert, James R; Friedman, Daniela B

    2018-07-01

    Prostate cancer (PrCA) is the most common cancer affecting men in the United States, and African American men have the highest incidence among men in the United States. Little is known about the PrCA-related educational materials being provided to patients in health-care settings. Content, readability, and cultural sensitivity of materials available in providers' practices in South Carolina were examined. A total of 44 educational materials about PrCA and associated sexual dysfunction was collected from 16 general and specialty practices. The content of the materials was coded, and cultural sensitivity was assessed using the Cultural Sensitivity Assessment Tool. Flesch Reading Ease, Flesch-Kincaid Grade Level, and the Simple Measure of Gobbledygook were used to assess readability. Communication with health-care providers (52.3%), side effects of PrCA treatment (40.9%), sexual dysfunction and its treatment (38.6%), and treatment options (34.1%) were frequently presented. All materials had acceptable cultural sensitivity scores; however, 2.3% and 15.9% of materials demonstrated unacceptable cultural sensitivity regarding format and visual messages, respectively. Readability of the materials varied. More than half of the materials were written above a high-school reading level. PrCA-related materials available in health-care practices may not meet patients' needs regarding content, cultural sensitivity, and readability. A wide range of educational materials that address various aspects of PrCA, including treatment options and side effects, should be presented in plain language and be culturally sensitive.

  19. An improved Overhauser magnetometer for Earth's magnetic field observation

    NASA Astrophysics Data System (ADS)

    Fan, Shifang; Chen, Shudong; Zhang, Shuang; Guo, Xin; Cao, Qiong

    2016-09-01

    Overhauser magnetometer is a kind of high-precision devices for magnetostatic field measurement. It is widely used in geological survey, earth field variations, UXO detection etc. However, the original Overhauser magnetometer JOM-2 shows great shortcomings of low signal to noise ratio (SNR) and high power consumption, which directly affect the performance of the device. In order to increase the sensitivity and reduce power consumption, we present an improved Overhauser magnetometer. Firstly, compared with the original power board which suffers from heavy noise for improper EMC design, an improved power broad with 20mV peak to peak noise is presented in this paper. Then, the junction field effect transistor (JFET) is used as pre-amplifier in our new design, to overcome the higher current noise produced by the original instrumentation amplifier. By adjusting the parameters carefully low noise factor down to 0.5 dB can be obtained. Finally, the new architecture of ARM + CPLD is adopted to replace the original one with DSP+CPLD. So lower power consumption and greater flash memory can be realized. With these measures, an improved Overhauser magnetometer with higher sensitivity and lower power consumption is design here. The experimental results indicate that the sensitivity of the improved Overhauser magnetometer is 0.071nT, which confirms that the new magnetometer is sensitive to earth field measurement.

  20. High regional climate sensitivity over continental China constrained by glacial-recent changes in temperature and the hydrological cycle.

    PubMed

    Eagle, Robert A; Risi, Camille; Mitchell, Jonathan L; Eiler, John M; Seibt, Ulrike; Neelin, J David; Li, Gaojun; Tripati, Aradhna K

    2013-05-28

    The East Asian monsoon is one of Earth's most significant climatic phenomena, and numerous paleoclimate archives have revealed that it exhibits variations on orbital and suborbital time scales. Quantitative constraints on the climate changes associated with these past variations are limited, yet are needed to constrain sensitivity of the region to changes in greenhouse gas levels. Here, we show central China is a region that experienced a much larger temperature change since the Last Glacial Maximum than typically simulated by climate models. We applied clumped isotope thermometry to carbonates from the central Chinese Loess Plateau to reconstruct temperature and water isotope shifts from the Last Glacial Maximum to present. We find a summertime temperature change of 6-7 °C that is reproduced by climate model simulations presented here. Proxy data reveal evidence for a shift to lighter isotopic composition of meteoric waters in glacial times, which is also captured by our model. Analysis of model outputs suggests that glacial cooling over continental China is significantly amplified by the influence of stationary waves, which, in turn, are enhanced by continental ice sheets. These results not only support high regional climate sensitivity in Central China but highlight the fundamental role of planetary-scale atmospheric dynamics in the sensitivity of regional climates to continental glaciation, changing greenhouse gas levels, and insolation.

  1. Adaptive interference cancel filter for evoked potential using high-order cumulants.

    PubMed

    Lin, Bor-Shyh; Lin, Bor-Shing; Chong, Fok-Ching; Lai, Feipei

    2004-01-01

    This paper is to present evoked potential (EP) processing using adaptive interference cancel (AIC) filter with second and high order cumulants. In conventional ensemble averaging method, people have to conduct repetitively experiments to record the required data. Recently, the use of AIC structure with second statistics in processing EP has proved more efficiency than traditional averaging method, but it is sensitive to both of the reference signal statistics and the choice of step size. Thus, we proposed higher order statistics-based AIC method to improve these disadvantages. This study was experimented in somatosensory EP corrupted with EEG. Gradient type algorithm is used in AIC method. Comparisons with AIC filter on second, third, fourth order statistics are also presented in this paper. We observed that AIC filter with third order statistics has better convergent performance for EP processing and is not sensitive to the selection of step size and reference input.

  2. Emotion improves and impairs early vision.

    PubMed

    Bocanegra, Bruno R; Zeelenberg, René

    2009-06-01

    Recent studies indicate that emotion enhances early vision, but the generality of this finding remains unknown. Do the benefits of emotion extend to all basic aspects of vision, or are they limited in scope? Our results show that the brief presentation of a fearful face, compared with a neutral face, enhances sensitivity for the orientation of subsequently presented low-spatial-frequency stimuli, but diminishes orientation sensitivity for high-spatial-frequency stimuli. This is the first demonstration that emotion not only improves but also impairs low-level vision. The selective low-spatial-frequency benefits are consistent with the idea that emotion enhances magnocellular processing. Additionally, we suggest that the high-spatial-frequency deficits are due to inhibitory interactions between magnocellular and parvocellular pathways. Our results suggest an emotion-induced trade-off in visual processing, rather than a general improvement. This trade-off may benefit perceptual dimensions that are relevant for survival at the expense of those that are less relevant.

  3. High Sensitivity Terahertz Detection through Large-Area Plasmonic Nano-Antenna Arrays.

    PubMed

    Yardimci, Nezih Tolga; Jarrahi, Mona

    2017-02-16

    Plasmonic photoconductive antennas have great promise for increasing responsivity and detection sensitivity of conventional photoconductive detectors in time-domain terahertz imaging and spectroscopy systems. However, operation bandwidth of previously demonstrated plasmonic photoconductive antennas has been limited by bandwidth constraints of their antennas and photoconductor parasitics. Here, we present a powerful technique for realizing broadband terahertz detectors through large-area plasmonic photoconductive nano-antenna arrays. A key novelty that makes the presented terahertz detector superior to the state-of-the art is a specific large-area device geometry that offers a strong interaction between the incident terahertz beam and optical pump at the nanoscale, while maintaining a broad operation bandwidth. The large device active area allows robust operation against optical and terahertz beam misalignments. We demonstrate broadband terahertz detection with signal-to-noise ratio levels as high as 107 dB.

  4. High Sensitivity Terahertz Detection through Large-Area Plasmonic Nano-Antenna Arrays

    PubMed Central

    Yardimci, Nezih Tolga; Jarrahi, Mona

    2017-01-01

    Plasmonic photoconductive antennas have great promise for increasing responsivity and detection sensitivity of conventional photoconductive detectors in time-domain terahertz imaging and spectroscopy systems. However, operation bandwidth of previously demonstrated plasmonic photoconductive antennas has been limited by bandwidth constraints of their antennas and photoconductor parasitics. Here, we present a powerful technique for realizing broadband terahertz detectors through large-area plasmonic photoconductive nano-antenna arrays. A key novelty that makes the presented terahertz detector superior to the state-of-the art is a specific large-area device geometry that offers a strong interaction between the incident terahertz beam and optical pump at the nanoscale, while maintaining a broad operation bandwidth. The large device active area allows robust operation against optical and terahertz beam misalignments. We demonstrate broadband terahertz detection with signal-to-noise ratio levels as high as 107 dB. PMID:28205615

  5. Apparatus for molecular weight separation

    DOEpatents

    Smith, Richard D.; Liu, Chuanliang

    2001-01-01

    The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations (0-2.5 mM NH4OAc) of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, (4) conducting a two-stage separation or (5) any combination of (1), (2), (3) and (4).

  6. Microdialysis unit for molecular weight separation

    DOEpatents

    Smith, Richard D.; Liu, Chuanliang

    1999-01-01

    The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations (0-2.5 mM NH4OAc) of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, or (4) any combination of (1), (2), and (3).

  7. Searching for the full symphony of black hole binary mergers

    NASA Astrophysics Data System (ADS)

    Harry, Ian; Bustillo, Juan Calderón; Nitz, Alex

    2018-01-01

    Current searches for the gravitational-wave signature of compact binary mergers rely on matched-filtering data from interferometric observatories with sets of modeled gravitational waveforms. These searches currently use model waveforms that do not include the higher-order mode content of the gravitational-wave signal. Higher-order modes are important for many compact binary mergers and their omission reduces the sensitivity to such sources. In this work we explore the sensitivity loss incurred from omitting higher-order modes. We present a new method for searching for compact binary mergers using waveforms that include higher-order mode effects, and evaluate the sensitivity increase that using our new method would allow. We find that, when evaluating sensitivity at a constant rate-of-false alarm, and when including the fact that signal-consistency tests can reject some signals that include higher-order mode content, we observe a sensitivity increase of up to a factor of 2 in volume for high mass ratio, high total-mass systems. For systems with equal mass, or with total mass ˜50 M⊙, we see more modest sensitivity increases, <10 %, which indicates that the existing search is already performing well. Our new search method is also directly applicable in searches for generic compact binaries.

  8. Applications of nanopipettes in bionanotechnology.

    PubMed

    Ying, Liming

    2009-08-01

    At present, technical hurdles remain in probing biochemical processes in living cells and organisms at nanometre spatial resolution, millisecond time resolution and with high specificity and single-molecule sensitivity. Owing to its unique shape, size and electrical properties, the nanopipette has been used to obtain high-resolution topographic images of live cells under physiological conditions, and to create nanoscale features by controlled delivery of biomolecules. In the present paper, I discuss recent progress in the development of a family of new methods for nanosensing and nanomanipulation using nanopipettes.

  9. Sensitivity and specificity: twin goals of proteomics assays. Can they be combined?

    PubMed

    Wilson, Robert

    2013-04-01

    A major ambition of proteomics is the provision of assays that can diagnose disease and monitor therapies. These assays are required to be sensitive and specific for individual proteins, and in most cases to quantify more than one protein in the same sample. The two main technologies currently used for proteomics assays are based on mass spectrometry and panels of affinity molecules such as antibodies. In the first part of this review the most sensitive existing assays based on these technologies are described and compared with the gold standard of ELISA. Analytical sensitivity is defined and related to the limit of detection, and analytical specificity is defined and shown to depend on molecular proofreading steps, similar to those applied in living systems whenever there is a need for high fidelity. It is shown that at present neither mass spectrometry nor panels of affinity molecules offer the necessary combination of sensitivity and specificity required for multiplexed assays. In the second part of this review the growing numbers of assays that use additional proofreading steps to combine sensitivity with specificity are described. These include assays based on proximity ligation and slow off-rate modified aptamers. Finally the review considers what improvements might be possible in the near future, and concludes that further development of proteomics assays incorporating advanced proofreading steps are most likely to provide the necessary combination of sensitivity and specificity, without incurring high development costs.

  10. Comparison of the new high sensitive cardiac troponin T with myoglobin, h-FABP and cTnT for early identification of myocardial necrosis in the acute coronary syndrome.

    PubMed

    Kurz, Kerstin; Giannitsis, Evangelos; Becker, Maike; Hess, Georg; Zdunek, Dietmar; Katus, Hugo A

    2011-03-01

    We sought to determine the performance of the new high sensitivity cardiac troponin T assay (TnThs) for early diagnosis of myocardial infarction in patients with suspected acute coronary syndrome (ACS) and compare it with the fourth generation cTnT assay, myoglobin and heart-type fatty acid binding protein (h-FABP). Ninety-four patients with diagnosis of suspected ACS without ST-segment elevation admitted to our chest pain unit were included. Patients were divided according to time from onset of symptoms to presentation into an early presenter group (<4 h) and a late presenter group (≥4 h). A median of six samples (range 2-8) were available per patient. The diagnostic performance of TnThs was assessed using ROC analysis. Areas under the curve (AUC) of baseline and follow-up results of TnThs, cTnT, myoglobin, and h-FABP were compared using c statistics. The TnThs assay allows an excellent prediction of non-ST-segment elevation myocardial infarction (non-STEMI) at presentation, particularly among late presenters. A follow-up sample improves diagnostic performance in a time-dependent manner. The AUC of TnThs was superior to cTnT at all time points. The performance of TnThs was at least as good as myoglobin and h-FABP at presentation and during follow-up. A baseline sample of TnThs allows an earlier prediction of non-STEMI than the less sensitive and precise fourth generation cTnT assay. Probably, this excellent performance of TnThs at baseline and follow-up could obviate the need for other early markers of necrosis in future.

  11. A CMOS-based large-area high-resolution imaging system for high-energy x-ray applications

    NASA Astrophysics Data System (ADS)

    Rodricks, Brian; Fowler, Boyd; Liu, Chiao; Lowes, John; Haeffner, Dean; Lienert, Ulrich; Almer, John

    2008-08-01

    CCDs have been the primary sensor in imaging systems for x-ray diffraction and imaging applications in recent years. CCDs have met the fundamental requirements of low noise, high-sensitivity, high dynamic range and spatial resolution necessary for these scientific applications. State-of-the-art CMOS image sensor (CIS) technology has experienced dramatic improvements recently and their performance is rivaling or surpassing that of most CCDs. The advancement of CIS technology is at an ever-accelerating pace and is driven by the multi-billion dollar consumer market. There are several advantages of CIS over traditional CCDs and other solid-state imaging devices; they include low power, high-speed operation, system-on-chip integration and lower manufacturing costs. The combination of superior imaging performance and system advantages makes CIS a good candidate for high-sensitivity imaging system development. This paper will describe a 1344 x 1212 CIS imaging system with a 19.5μm pitch optimized for x-ray scattering studies at high-energies. Fundamental metrics of linearity, dynamic range, spatial resolution, conversion gain, sensitivity are estimated. The Detective Quantum Efficiency (DQE) is also estimated. Representative x-ray diffraction images are presented. Diffraction images are compared against a CCD-based imaging system.

  12. Moral sensitivity and moral distress in Iranian critical care nurses.

    PubMed

    Borhani, Fariba; Abbaszadeh, Abbas; Mohamadi, Elham; Ghasemi, Erfan; Hoseinabad-Farahani, Mohammad Javad

    2017-06-01

    Moral sensitivity is the foremost prerequisite to ethical performance; a review of literature shows that nurses are sometimes not sensitive enough for a variety of reasons. Moral distress is a frequent phenomenon in nursing, which may result in paradoxes in care, dealing with patients and rendering high-quality care. This may, in turn, hinder the meeting of care objectives, thus affecting social healthcare standards. The present research was conducted to determine the relationship between moral sensitivity and moral distress of nurses in intensive care units. This study is a descriptive-correlation research. Lutzen's moral sensitivity questionnaire and Corley Moral Distress Questionnaire were used to gather data. Participants and research context: A total of 153 qualified nurses working in the hospitals affiliated to Shahid Beheshti University of Medical Sciences were selected for this study. Subjects were selected by census method. Ethical considerations: After explaining the objectives of the study, all the participants completed and signed the written consent form. To conduct the study, permission was obtained from the selected hospitals. Nurses' average moral sensitivity grade was 68.6 ± 7.8, which shows a moderate level of moral sensitivity. On the other hand, nurses also experienced a moderate level of moral distress (44.8 ± 16.6). Moreover, there was no meaningful statistical relationship between moral sensitivity and moral distress (p = 0.26). Although the nurses' moral sensitivity and moral distress were expected to be high in the intensive care units, it was moderate. This finding is consistent with the results of some studies and contradicts with others. As moral sensitivity is a crucial factor in care, it is suggested that necessary training be provided to develop moral sensitivity in nurses in education and practical environments. Furthermore, removing factors that contribute to moral distress may help decrease it in nurses.

  13. Punishment sensitivity modulates the processing of negative feedback but not error-induced learning.

    PubMed

    Unger, Kerstin; Heintz, Sonja; Kray, Jutta

    2012-01-01

    Accumulating evidence suggests that individual differences in punishment and reward sensitivity are associated with functional alterations in neural systems underlying error and feedback processing. In particular, individuals highly sensitive to punishment have been found to be characterized by larger mediofrontal error signals as reflected in the error negativity/error-related negativity (Ne/ERN) and the feedback-related negativity (FRN). By contrast, reward sensitivity has been shown to relate to the error positivity (Pe). Given that Ne/ERN, FRN, and Pe have been functionally linked to flexible behavioral adaptation, the aim of the present research was to examine how these electrophysiological reflections of error and feedback processing vary as a function of punishment and reward sensitivity during reinforcement learning. We applied a probabilistic learning task that involved three different conditions of feedback validity (100%, 80%, and 50%). In contrast to prior studies using response competition tasks, we did not find reliable correlations between punishment sensitivity and the Ne/ERN. Instead, higher punishment sensitivity predicted larger FRN amplitudes, irrespective of feedback validity. Moreover, higher reward sensitivity was associated with a larger Pe. However, only reward sensitivity was related to better overall learning performance and higher post-error accuracy, whereas highly punishment sensitive participants showed impaired learning performance, suggesting that larger negative feedback-related error signals were not beneficial for learning or even reflected maladaptive information processing in these individuals. Thus, although our findings indicate that individual differences in reward and punishment sensitivity are related to electrophysiological correlates of error and feedback processing, we found less evidence for influences of these personality characteristics on the relation between performance monitoring and feedback-based learning.

  14. [Psychological Well-being of Highly-sensitive Persons in Transition to Parenthood - A Cross-sectional Study].

    PubMed

    Schmückle, M; Lindert, J; Schmolz, G

    2017-12-01

    Well-being of highly sensitive people in the transformation period to parenthood is of increasing concern. This study examines whether the transformation period to parenthood has a higher effect on the psychological well-being (PWB) of highly sensitive people than on not highly sensitive people. A cross-sectional study was undertaken of parents (n=614), highly sensitive (n=440) and not highly sensitive (n=174), at the transition to parenthood. Instruments were the Ryff psychological well-being scale. Independent variables and well-being were examined by descriptive and bivariate methods. Well-being of highly sensitive parents is associated with transition to parenthood (b=-10,129; p<0.05) compared to the control group (7.3% of highly sensitive <50% of PWB; 0.6% of not highly sensitive <50% of PWB). As one of the first studies, this examination looks into the data of highly sensitive parents. It can be stated that there is an urgent need for research in this area. Because with a prevalence of 10-20% highly sensitive people within the population, it can be assumed that highly sensitive mostly young parents, could be an important target group of health promotion. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Advanced technique for ultra-thin residue inspection with sub-10nm thickness using high-energy back-scattered electrons

    NASA Astrophysics Data System (ADS)

    Han, Jin-Hee

    2018-03-01

    Recently the aspect ratio of capacitor and via hole of memory semiconductor device has been dramatically increasing in order to store more information in a limited area. A small amount of remained residues after etch process on the bottom of the high aspect ratio structure can make a critical failure in device operation. Back-scattered electrons (BSE) are mainly used for inspecting the defect located at the bottom of the high aspect ratio structure or analyzing the overlay of the multi-layer structure because these electrons have a high linearity with the direction of emission and a high kinetic energy above 50eV. However, there is a limitation on that it cannot detect ultra-thin residue material having a thickness of several nanometers because the surface sensitivity is extremely low. We studied the characteristics of BSE spectra using Monte Carlo simulations for several cases which the high aspect ratio structures have extreme microscopic residues. Based on the assumption that most of the electrons emitted without energy loss are localized on the surface, we selected the detection energy window which has a range of 20eV below the maximum energy of the BSE. This window section is named as the high-energy BSE region. As a result of comparing the detection sensitivity of the conventional and the high-energy BSE detection mode, we found that the detection sensitivity for the residuals which have 2nm thickness is improved by more than 10 times in the high-energy BSE mode. This BSE technology is a new inspection method that can greatly be improved the inspection sensitivity for the ultra-thin residual material presented in the high aspect ratio structure, and its application will be expanded.

  16. Asymmetric split-ring resonator-based biosensor for detection of label-free stress biomarkers

    NASA Astrophysics Data System (ADS)

    Lee, Hee-Jo; Lee, Jung-Hyun; Choi, Suji; Jang, Ik-Soon; Choi, Jong-Soon; Jung, Hyo-Il

    2013-07-01

    In this paper, an asymmetric split-ring resonator, metamaterial element, is presented as a biosensing transducer for detection of highly sensitive and label-free stress biomarkers. In particular, the two biomarkers, cortisol and α-amylase, are used for evaluating the sensitivity of the proposed biosensor. In case of cortisol detection, the competitive reaction between cortisol-bovine serum albumin and free cortisol is employed, while alpha-amylase is directly detected by its antigen-antibody reaction. From the experimental results, we find that the limit of detection and sensitivity of the proposed sensing device are about 1 ng/ml and 1.155 MHz/ng ml-1, respectively.

  17. Improving the sensitivity and accuracy of gamma activation analysis for the rapid determination of gold in mineral ores.

    PubMed

    Tickner, James; Ganly, Brianna; Lovric, Bojan; O'Dwyer, Joel

    2017-04-01

    Mining companies rely on chemical analysis methods to determine concentrations of gold in mineral ore samples. As gold is often mined commercially at concentrations around 1 part-per-million, it is necessary for any analysis method to provide good sensitivity as well as high absolute accuracy. We describe work to improve both the sensitivity and accuracy of the gamma activation analysis (GAA) method for gold. We present analysis results for several suites of ore samples and discuss the design of a GAA facility designed to replace conventional chemical assay in industrial applications. Copyright © 2017. Published by Elsevier Ltd.

  18. Expression profiling analysis: Uncoupling protein 2 deficiency improves hepatic glucose, lipid profiles and insulin sensitivity in high-fat diet-fed mice by modulating expression of genes in peroxisome proliferator-activated receptor signaling pathway.

    PubMed

    Zhou, Mei-Cen; Yu, Ping; Sun, Qi; Li, Yu-Xiu

    2016-03-01

    Uncoupling protein 2 (UCP2), which was an important mitochondrial inner membrane protein associated with glucose and lipid metabolism, widely expresses in all kinds of tissues including hepatocytes. The present study aimed to explore the impact of UCP2 deficiency on glucose and lipid metabolism, insulin sensitivity and its effect on the liver-associated signaling pathway by expression profiling analysis. Four-week-old male UCP2-/- mice and UCP2+/+ mice were randomly assigned to four groups: UCP2-/- on a high-fat diet, UCP2-/- on a normal chow diet, UCP2+/+ on a high-fat diet and UCP2+/+ on a normal chow diet. The differentially expressed genes in the four groups on the 16th week were identified by Affymetrix gene array. The results of intraperitoneal glucose tolerance test and insulin tolerance showed that blood glucose and β-cell function were improved in the UCP2-/- group on high-fat diet. Enhanced insulin sensitivity was observed in the UCP2-/- group. The differentially expressed genes were mapped to 23 pathways (P < 0.05). We concentrated on the 'peroxisome proliferator-activated receptor (PPAR) signaling pathway' (P = 3.19 × 10(-11)), because it is closely associated with the regulation of glucose and lipid profiles. In the PPAR signaling pathway, seven genes (PPARγ, Dbi, Acsl3, Lpl, Me1, Scd1, Fads2) in the UCP2-/- mice were significantly upregulated. The present study used gene arrays to show that activity of the PPAR signaling pathway involved in the improvement of glucose and lipid metabolism in the liver of UCP2-deficient mice on a long-term high-fat diet. The upregulation of genes in the PPAR signaling pathway could explain our finding that UCP2 deficiency ameliorated insulin sensitivity. The manipulation of UCP2 protein expression could represent a new strategy for the prevention and treatment of diabetes.

  19. A high-threshold heat-activated channel in cultured rat dorsal root ganglion neurons resembles TRPV2 and is blocked by gadolinium.

    PubMed

    Leffler, Andreas; Linte, Ramona Madalina; Nau, Carla; Reeh, Peter; Babes, Alexandru

    2007-07-01

    Heat-activated ion channels from the vanilloid-type TRP group (TRPV1-4) seem to be central for heat-sensitivity of nociceptive sensory neurons. Displaying a high-threshold (> 52 degrees C) for activation, TRPV2 was proposed to act as a sensor for intense noxious heat in mammalian sensory neurons. However, although TRPV2 is expressed in a distinct population of thinly myelinated primary afferents, a widespread expression in a variety of neuronal and non-neuronal tissues suggests a more diverse physiological role of TRPV2. In its role as a heat-sensor, TRPV2 has not been thoroughly characterized in terms of biophysical and pharmacological properties. In the present study, we demonstrate that the features of heterologously expressed rat TRPV2 closely resemble those of high-threshold heat-evoked currents in medium- and large-sized capsaicin-insensitive rat dorsal root ganglion (DRG) neurons. Both in TRPV2-expressing human embryonic kidney (HEK)293t cells and in DRGs, high-threshold heat-currents were sensitized by repeated activation and by the TRPV1-3 agonist, 2-aminoethoxydiphenyl borate (2-APB). In addition to a previously described block by ruthenium red, we identified the trivalent cations, lanthanum (La(3+)) and gadolinium (Gd(3+)) as potent blockers of TRPV2. Thus, we present a new pharmacological tool to distinguish between heat responses of TRPV2 and the closely related capsaicin-receptor, TRPV1, which is strongly sensitized by trivalent cations. We demonstrate that self-sensitization of heat-evoked currents through TRPV2 does not require extracellular calcium and that TRPV2 can be activated in cell-free membrane patches in the outside-out configuration. Taken together our results provide new evidence for a role of TRPV2 in mediating high-threshold heat responses in a subpopulation of mammalian sensory neurons.

  20. Highly Sensitive Multifilament Fiber Strain Sensors with Ultrabroad Sensing Range for Textile Electronics.

    PubMed

    Lee, Jaehong; Shin, Sera; Lee, Sanggeun; Song, Jaekang; Kang, Subin; Han, Heetak; Kim, SeulGee; Kim, Seunghoe; Seo, Jungmok; Kim, DaeEun; Lee, Taeyoon

    2018-05-22

    Highly stretchable fiber strain sensors are one of the most important components for various applications in wearable electronics, electronic textiles, and biomedical electronics. Herein, we present a facile approach for fabricating highly stretchable and sensitive fiber strain sensors by embedding Ag nanoparticles into a stretchable fiber with a multifilament structure. The multifilament structure and Ag-rich shells of the fiber strain sensor enable the sensor to simultaneously achieve both a high sensitivity and largely wide sensing range despite its simple fabrication process and components. The fiber strain sensor simultaneously exhibits ultrahigh gauge factors (∼9.3 × 10 5 and ∼659 in the first stretching and subsequent stretching, respectively), a very broad strain-sensing range (450 and 200% for the first and subsequent stretching, respectively), and high durability for more than 10 000 stretching cycles. The fiber strain sensors can also be readily integrated into a glove to control a hand robot and effectively applied to monitor the large volume expansion of a balloon and a pig bladder for an artificial bladder system, thereby demonstrating the potential of the fiber strain sensors as candidates for electronic textiles, wearable electronics, and biomedical engineering.

  1. [Screening interview for early detection of high-functioning autism spectrum disorders].

    PubMed

    Hoffmann, Wiebke; Heinzel-Gutenbrunner, Monika; Becker, Katja; Kamp-Becker, Inge

    2015-05-01

    Various different questionnaires are available for the screening of autism spectrum disorders (ASD). These screening instruments show high sensitivity and are able to identify a large number of individuals with ASD, but they lack the specificity to differentiate individuals with ASD from those children and adolescents with other complex neurobehavioural disorders (such as attention-deficit/hyperactivity disorder, emotional disorders, and others), especially for those without intellectual disabilities. The present study evaluates the data of 309 individuals (153 with high-functioning ASD, 156 with other psychiatric disorders, IQ > 70) to find out whether selected items of the ADI-R can be used for an economic and sensitive screening of high-functioning ASD. The results show that 8 items of the ADI-R can be used to discriminate high-functioning ASD and other psychiatric disorders. A cutoff of 5 led to a sensitivity of 0.93 and a cutoff of 6 to a specificity of 0.74. The combination of early onset, serious abnormalities in social contact with stereotyped or compulsive-ritualized behaviour or interests can be detected with few interview questions for screening of ASD. Nevertheless, a more detailed and specific assessment in an expert setting should follow the screening process.

  2. Optical fiber evanescent absorption sensors for high-temperature gas sensing in advanced coal-fired power plants

    NASA Astrophysics Data System (ADS)

    Buric, Michael P.; Ohodnicky, Paul R.; Duy, Janice

    2012-10-01

    Modern advanced energy systems such as coal-fired power plants, gasifiers, or similar infrastructure present some of the most challenging harsh environments for sensors. The power industry would benefit from new, ultra-high temperature devices capable of surviving in hot and corrosive environments for embedded sensing at the highest value locations. For these applications, we are currently exploring optical fiber evanescent wave absorption spectroscopy (EWAS) based sensors consisting of high temperature core materials integrated with novel high temperature gas sensitive cladding materials. Mathematical simulations can be used to assist in sensor development efforts, and we describe a simulation code that assumes a single thick cladding layer with gas sensitive optical constants. Recent work has demonstrated that Au nanoparticle-incorporated metal oxides show a potentially useful response for high temperature optical gas sensing applications through the sensitivity of the localized surface plasmon resonance absorption peak to ambient atmospheric conditions. Hence, the simulation code has been applied to understand how such a response can be exploited in an optical fiber based EWAS sensor configuration. We demonstrate that interrogation can be used to optimize the sensing response in such materials.

  3. An experimental test of the effect of acute anxious arousal and anxiety sensitivity on negative reinforcement smoking.

    PubMed

    Farris, Samantha G; Zvolensky, Michael J

    2016-07-01

    Although anxiety sensitivity has been reliably associated with smoking-anxiety comorbidity, there has not been a test of whether this construct moderates the effect of acute anxious arousal on actual smoking behavior. The present study utilized an experimental design to test the moderating role of anxiety sensitivity on laboratory-induced anxious arousal in terms of smoking urges and topography (puff style). Participants were adult daily smokers (n=90; Mage=43.6 SD =9.7); average 15.8 cigarettes per day). A between-subjects design was used; participants were randomly assigned to complete a biological challenge procedure consisting of either a single vital capacity inhalation of 35% carbon dioxide (CO2)-enriched air mixture or compressed room air. Smoking urges and smoking topography (puff behavior) were assessed before and after the challenge. Results revealed a significant interaction between anxiety sensitivity and experimental condition (b=-9.96, p=0.014), such that high anxiety sensitive smokers exposed to 35% CO2-enriched air reported significantly lower levels of smoking urges, relative to low anxiety sensitive smokers; the conditional effect of anxiety sensitivity was not observed for the room air condition. There were no significant interaction effects of experimental manipulation by anxiety sensitivity for any of the smoking topography outcomes. The present results suggest for smokers with higher levels of anxiety sensitivity, the acute experience of anxious arousal is related to decreased subjective smoking urges. These data invite future research to explore the reasons for dampened smoking urges, including cardiorespiratory symptom severity. © The Author(s) 2016.

  4. Perceptual Learning Improves Contrast Sensitivity of V1 Neurons in Cats

    PubMed Central

    Hua, Tianmiao; Bao, Pinglei; Huang, Chang-Bing; Wang, Zhenhua; Xu, Jinwang

    2010-01-01

    Summary Background Perceptual learning has been documented in adult humans over a wide range of tasks. Although the often observed specificity of learning is generally interpreted as evidence for training-induced plasticity in early cortical areas, physiological evidence for training-induced changes in early visual cortical areas is modest, despite reports of learning-induced changes of cortical activities in fMRI studies. To reveal the physiological bases of perceptual learning, we combined psychophysical measurements with extracellular single-unit recording under anesthetized preparations, and examined the effects of training in grating orientation identification on both perceptual and neuronal contrast sensitivity functions of cats. Results We have found that training significantly improved perceptual contrast sensitivity of the cats to gratings with the spatial frequencies near the ‘trained’ spatial frequency, with stronger effects in the trained eye. Consistent with behavioral assessments, the mean contrast sensitivity of neurons recorded from V1 of the trained cats was significantly higher than that of neurons recorded from the untrained cats. Furthermore, in the trained cats, the contrast sensitivity of V1 neurons responding preferentially to stimuli presented via the trained eyes was significantly greater than that of neurons responding preferentially to stimuli presented via the ‘untrained’ eyes. The effect was confined to the trained spatial frequencies. In both trained and untrained cats, the neuronal contrast sensitivity functions derived from the contrast sensitivity of the individual neurons were highly correlated with behaviorally determined perceptual contrast sensitivity functions. Conclusions We suggest that training-induced neuronal contrast-gain in area V1 underlies behaviorally determined perceptual contrast sensitivity improvements. PMID:20451388

  5. Comparative theoretical studies of differently bridged nitramino-substituted ditetrazole 2-N-oxides with high detonation performance and an oxygen balance of around zero.

    PubMed

    Wu, Qiong; Kou, Bo; Hang, Zusheng; Zhu, Weihua

    2017-06-01

    In this work, six (A-F) nitramino (-NHNO 2 )-substituted ditetrazole 2-N-oxides with different bridging groups (-CH 2 -, -CH 2 -CH 2 -, -NH-, -N=N-, and -NH-NH-) were designed. The six compounds were based on the parent compound tetrazole 2-N-oxide, which possesses a high oxygen balance and high density. The structure, heat of formation, density, detonation properties (detonation velocity D and detonation pressure P), and the sensitivity of each compound was investigated systematically via density functional theory, by studying the electrostatic potential, and using molecular mechanics. The results showed that compounds A-F all have outstanding energetic properties (D: 9.1-10.0 km/s; P: 38.0-46.7 GPa) and acceptable sensitivities (h 50 : 28-37 cm). The bridging group present was found to greatly affect the detonation performance of each ditetrazole 2-N-oxide, and the compound with the -NH-NH- bridging group yielded the best results. Indeed, this compound (F) was calculated to have comparable sensitivity to the famous and widely used high explosive 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX), but with values of D and P that were about 8.7% and 19.4% higher than those for HMX, respectively. The present study shows that tetrazole 2-N-oxide is a useful parent compound which could potentially be used in the design of new and improved high-energy compounds to replace existing energetic compounds such as HMX.

  6. Cultural Sensitivity Among Clinical Nurses: A Descriptive Study.

    PubMed

    Yilmaz, Medine; Toksoy, Serap; Direk, Zübeyde Denizci; Bezirgan, Selma; Boylu, Münevver

    2017-03-01

    The purpose of this study was to investigate the cultural sensitivity of nurses working in rural and urban hospitals in Turkey. The sampling of this descriptive and correlational study was composed of only 516 clinical nurses working in inpatient clinics. The data collection tools were the Socio-Demographic Questionnaire and the Intercultural Sensitivity Scale. A majority of the participating nurses experienced culture-related problems. Intercultural Sensitivity Scale results were partially high. The nurses had more problems in areas related to language barriers, patients' education level, and health perception about disease and religious beliefs when providing health care. Participants who were female, had an undergraduate or graduate education, had received in-service education on cultural care, or had taken transcultural nursing coursework obtained higher scores on the Intercultural Sensitivity Scale and its Interaction Engagement subscale. The cultural sensitivity level was 84.01 ± 9.1 (range = 43-107). The proportion of nurses who had received no in-service education was very high. They wanted to participate in an education program to gain better understanding of the culture of the society in which they lived. The results of the present study demonstrated that nurses should be prepared in cultural sensitivity and cultural competence. Continuing education and formal courses on cultural sensitivity for nursing professionals are essential for optimal health outcomes. Thus, inequalities in health could be prevented and the quality of health care could be improved. © 2017 Sigma Theta Tau International.

  7. Energetic-Energetic Cocrystals of Diacetone Diperoxide (DADP): Dramatic and Divergent Sensitivity Modifications via Cocrystallization.

    PubMed

    Landenberger, Kira B; Bolton, Onas; Matzger, Adam J

    2015-04-22

    Here we report a series of energetic-energetic cocrystals that incorporate the primary explosive diacetone diperoxide (DADP) with a series of trihalotrinitrobenzene explosives: 1:1 DADP/1,3,5-trichloro-2,4,6-trinitrobenzene (TCTNB), 1:1 DADP/1,3,5-tribromo-2,4,6-trinitrobenzene (TBTNB), and 1:1 DADP/1,3,5-triiodo-2,4,6-trinitrobenzene (TITNB). Acetone peroxides are attractive for their inexpensive and facile synthesis, but undesirable properties such as poor stability, intractably high sensitivity and low density, an indicator for low explosive power, have limited their application. Here through cocrystallization the density, oxygen balance, and stability of DADP are dramatically improved. Regarding sensitivity, in the case of the DADP/TCTNB cocrystal, the high impact sensitivity of DADP is retained by the cocrystal, making it a denser and less volatile form of DADP that remains viable as a primary explosive. Conversely, the DADP/TITNB cocrystal features impact sensitivity that is greatly reduced relative to both pure DADP and pure TITNB, demonstrating for the first time an energetic cocrystal that is less sensitive to impact than either of its pure components. This dramatic difference in cocrystal sensitivities may stem from the significantly different halogen-peroxide interactions seen in each cocrystal structure. These results highlight how sensitivity is defined by complex relationships between inherent bond strengths and solid-state properties, and cocrystal series such as that presented here provide a powerful experimental platform to probe this relationship.

  8. Electrochemical Glucose Biosensor of Platinum Nanospheres Connected by Carbon Nanotubes

    PubMed Central

    Claussen, Jonathan C.; Kim, Sungwon S.; Haque, Aeraj ul; Artiles, Mayra S.; Porterfield, D. Marshall; Fisher, Timothy S.

    2010-01-01

    Background Glucose biosensors comprised of nanomaterials such as carbon nanotubes (CNTs) and metallic nanoparticles offer enhanced electrochemical performance that produces highly sensitive glucose sensing. This article presents a facile biosensor fabrication and biofunctionalization procedure that utilizes CNTs electrochemically decorated with platinum (Pt) nanospheres to sense glucose amperometrically with high sensitivity. Method Carbon nanotubes are grown in situ by microwave plasma chemical vapor deposition (MPCVD) and electro-chemically decorated with Pt nanospheres to form a CNT/Pt nanosphere composite biosensor. Carbon nanotube electrodes are immobilized with fluorescently labeled bovine serum albumin (BSA) and analyzed with fluorescence microscopy to demonstrate their biocompatibility. The enzyme glucose oxidase (GOX) is immobilized onto the CNT/Pt nanosphere biosensor by a simple drop-coat method for amperometric glucose sensing. Results Fluorescence microscopy demonstrates the biofunctionalization capability of the sensor by portraying adsorption of fluorescently labeled BSA unto MPCVD-grown CNT electrodes. The subsequent GOX–CNT/Pt nanosphere biosensor demonstrates a high sensitivity toward H2O2 (7.4 μA/mM/cm2) and glucose (70 μA/mM/cm2), with a glucose detection limit and response time of 380 nM (signal-to-noise ratio = 3) and 8 s (t90%), respectively. The apparent Michaelis–Menten constant (0.64 mM) of the biosensor also reflects the improved sensitivity of the immobilized GOX/nanomaterial complexes. Conclusions The GOX–CNT/Pt nanosphere biosensor outperforms similar CNT, metallic nanoparticle, and more conventional carbon-based biosensors in terms of glucose sensitivity and detection limit. The biosensor fabrication and biofunctionalization scheme can easily be scaled and adapted for microsensors for physiological research applications that require highly sensitive glucose sensing. PMID:20307391

  9. Electrochemical glucose biosensor of platinum nanospheres connected by carbon nanotubes.

    PubMed

    Claussen, Jonathan C; Kim, Sungwon S; Haque, Aeraj Ul; Artiles, Mayra S; Porterfield, D Marshall; Fisher, Timothy S

    2010-03-01

    Glucose biosensors comprised of nanomaterials such as carbon nanotubes (CNTs) and metallic nanoparticles offer enhanced electrochemical performance that produces highly sensitive glucose sensing. This article presents a facile biosensor fabrication and biofunctionalization procedure that utilizes CNTs electrochemically decorated with platinum (Pt) nanospheres to sense glucose amperometrically with high sensitivity. Carbon nanotubes are grown in situ by microwave plasma chemical vapor deposition (MPCVD) and electro-chemically decorated with Pt nanospheres to form a CNT/Pt nanosphere composite biosensor. Carbon nanotube electrodes are immobilized with fluorescently labeled bovine serum albumin (BSA) and analyzed with fluorescence microscopy to demonstrate their biocompatibility. The enzyme glucose oxidase (GO(X)) is immobilized onto the CNT/Pt nanosphere biosensor by a simple drop-coat method for amperometric glucose sensing. Fluorescence microscopy demonstrates the biofunctionalization capability of the sensor by portraying adsorption of fluorescently labeled BSA unto MPCVD-grown CNT electrodes. The subsequent GO(X)-CNT/Pt nanosphere biosensor demonstrates a high sensitivity toward H(2)O(2) (7.4 microA/mM/cm(2)) and glucose (70 microA/mM/cm(2)), with a glucose detection limit and response time of 380 nM (signal-to-noise ratio = 3) and 8 s (t(90%)), respectively. The apparent Michaelis-Menten constant (0.64 mM) of the biosensor also reflects the improved sensitivity of the immobilized GO(X)/nanomaterial complexes. The GO(X)-CNT/Pt nanosphere biosensor outperforms similar CNT, metallic nanoparticle, and more conventional carbon-based biosensors in terms of glucose sensitivity and detection limit. The biosensor fabrication and biofunctionalization scheme can easily be scaled and adapted for microsensors for physiological research applications that require highly sensitive glucose sensing. (c) 2010 Diabetes Technology Society.

  10. Flammability and sensitivity of materials in oxygen-enriched atmospheres; Proceedings of the Fourth International Symposium, Las Cruces, NM, Apr. 11-13, 1989. Volume 4

    NASA Technical Reports Server (NTRS)

    Stoltzfus, Joel M. (Editor); Benz, Frank J. (Editor); Stradling, Jack S. (Editor)

    1989-01-01

    The present volume discusses the ignition of nonmetallic materials by the impact of high-pressure oxygen, the promoted combustion of nine structural metals in high-pressure gaseous oxygen, the oxygen sensitivity/compatibility ranking of several materials by different test methods, the ignition behavior of silicon greases in oxygen atmospheres, fire spread rates along cylindrical metal rods in high-pressure oxygen, and the design of an ignition-resistant, high pressure/temperature oxygen valve. Also discussed are the promoted ignition of oxygen regulators, the ignition of PTFE-lined flexible hoses by rapid pressurization with oxygen, evolving nonswelling elastomers for high-pressure oxygen environments, the evaluation of systems for oxygen service through the use of the quantitative fault-tree analysis, and oxygen-enriched fires during surgery of the head and neck.

  11. Advances in HgCdTe APDs and LADAR Receivers

    NASA Technical Reports Server (NTRS)

    Bailey, Steven; McKeag, William; Wang, Jinxue; Jack, Michael; Amzajerdian, Farzin

    2010-01-01

    Raytheon is developing NIR sensor chip assemblies (SCAs) for scanning and staring 3D LADAR systems. High sensitivity is obtained by integrating high performance detectors with gain i.e. APDs with very low noise Readout Integrated Circuits. Unique aspects of these designs include: independent acquisition (non-gated) of pulse returns, multiple pulse returns with both time and intensity reported to enable full 3D reconstruction of the image. Recent breakthrough in device design has resulted in HgCdTe APDs operating at 300K with essentially no excess noise to gains in excess of 100, low NEP <1nW and GHz bandwidths and have demonstrated linear mode photon counting. SCAs utilizing these high performance APDs have been integrated and demonstrated excellent spatial and range resolution enabling detailed 3D imagery both at short range and long ranges. In this presentation we will review progress in high resolution scanning, staring and ultra-high sensitivity photon counting LADAR sensors.

  12. A high resolution on-chip delay sensor with low supply-voltage sensitivity for high-performance electronic systems.

    PubMed

    Sheng, Duo; Lai, Hsiu-Fan; Chan, Sheng-Min; Hong, Min-Rong

    2015-02-13

    An all-digital on-chip delay sensor (OCDS) circuit with high delay-measurement resolution and low supply-voltage sensitivity for efficient detection and diagnosis in high-performance electronic system applications is presented. Based on the proposed delay measurement scheme, the quantization resolution of the proposed OCDS can be reduced to several picoseconds. Additionally, the proposed cascade-stage delay measurement circuit can enhance immunity to supply-voltage variations of the delay measurement resolution without extra self-biasing or calibration circuits. Simulation results show that the delay measurement resolution can be improved to 1.2 ps; the average delay resolution variation is 0.55% with supply-voltage variations of ±10%. Moreover, the proposed delay sensor can be implemented in an all-digital manner, making it very suitable for high-performance electronic system applications as well as system-level integration.

  13. Label-Free Electrical Immunosensor for Highly Sensitive and Specific Detection of Microcystin-LR in Water Samples.

    PubMed

    Tan, Feng; Saucedo, Nuvia Maria; Ramnani, Pankaj; Mulchandani, Ashok

    2015-08-04

    Microcystin-LR (MCLR) is one of the most commonly detected and toxic cyclic heptapeptide cyanotoxins released by cyanobacterial blooms in surface waters, for which sensitive and specific detection methods are necessary to carry out its recognition and quantification. Here, we present a single-walled carbon nanotube (SWCNTs)-based label-free chemiresistive immunosensor for highly sensitive and specific detection of MCLR in different source waters. MCLR was initially immobilized on SWCNTs modified interdigitated electrode, followed by incubation with monoclonal anti-MCLR antibody. The competitive binding of MCLR in sample solutions induced departure of the antibody from the antibody-antigen complexes formed on SWCNTs, resulting in change in the conductivity between source and drain of the sensor. The displacement assay greatly improved the sensitivity of the sensor compared with direct immunoassay on the same device. The immunosensor exhibited a wide linear response to log value of MCLR concentration ranging from 1 to 1000 ng/L, with a detection limit of 0.6 ng/L. This method showed good reproducibility, stability and recovery. The proposed method provides a powerful tool for rapid and sensitive monitoring of MCLR in environmental samples.

  14. Higher climatological temperature sensitivity of soil carbon in cold than warm climates

    NASA Astrophysics Data System (ADS)

    Koven, Charles D.; Hugelius, Gustaf; Lawrence, David M.; Wieder, William R.

    2017-11-01

    The projected loss of soil carbon to the atmosphere resulting from climate change is a potentially large but highly uncertain feedback to warming. The magnitude of this feedback is poorly constrained by observations and theory, and is disparately represented in Earth system models (ESMs). To assess the climatological temperature sensitivity of soil carbon, we calculate apparent soil carbon turnover times that reflect long-term and broad-scale rates of decomposition. Here, we show that the climatological temperature control on carbon turnover in the top metre of global soils is more sensitive in cold climates than in warm climates and argue that it is critical to capture this emergent ecosystem property in global-scale models. We present a simplified model that explains the observed high cold-climate sensitivity using only the physical scaling of soil freeze-thaw state across climate gradients. Current ESMs fail to capture this pattern, except in an ESM that explicitly resolves vertical gradients in soil climate and carbon turnover. An observed weak tropical temperature sensitivity emerges in a different model that explicitly resolves mineralogical control on decomposition. These results support projections of strong carbon-climate feedbacks from northern soils and demonstrate a method for ESMs to capture this emergent behaviour.

  15. Behavioral profiles of feline breeds in Japan.

    PubMed

    Takeuchi, Yukari; Mori, Yuji

    2009-08-01

    To clarify the behavioral profiles of 9 feline purebreds, 2 Persian subbreeds and the Japanese domestic cat, a questionnaire survey was distributed to 67 small-animal veterinarians. We found significant differences among breeds in all behavioral traits examined except for "inappropriate elimination". In addition, sexual differences were observed in certain behaviors, including "aggression toward cats", "general activity", "novelty-seeking", and "excitability". These behaviors were more common in males than females, whereas "nervousness" and "inappropriate elimination" were rated higher in females. When all breeds were categorized into four groups on the basis of a cluster analysis using the scores of two behavioral trait factors called "aggressiveness/sensitivity" and "vivaciousness", the group including Abyssinian, Russian Blue, Somali, Siamese, and Chinchilla breeds showed high aggressiveness/sensitivity and low vivaciousness. In contrast, the group including the American Shorthair and Japanese domestic cat displayed low aggressiveness/sensitivity and high vivaciousness, and the Himalayan and Persian group showed mild aggressiveness/sensitivity and very low vivaciousness. Finally, the group containing Maine Coon, Ragdoll, and Scottish Fold breeds displayed very low aggressiveness/sensitivity and low vivaciousness. The present results demonstrate that some feline behavioral traits vary by breed and/or sex.

  16. Dramatic pressure-sensitive ion conduction in conical nanopores.

    PubMed

    Jubin, Laetitia; Poggioli, Anthony; Siria, Alessandro; Bocquet, Lydéric

    2018-04-17

    Ion transporters in Nature exhibit a wealth of complex transport properties such as voltage gating, activation, and mechanosensitive behavior. When combined, such processes result in advanced ionic machines achieving active ion transport, high selectivity, or signal processing. On the artificial side, there has been much recent progress in the design and study of transport in ionic channels, but mimicking the advanced functionalities of ion transporters remains as yet out of reach. A prerequisite is the development of ionic responses sensitive to external stimuli. In the present work, we report a counterintuitive and highly nonlinear coupling between electric and pressure-driven transport in a conical nanopore, manifesting as a strong pressure dependence of the ionic conductance. This result is at odds with standard linear response theory and is akin to a mechanical transistor functionality. We fully rationalize this behavior on the basis of the coupled electrohydrodynamics in the conical pore by extending the Poisson-Nernst-Planck-Stokes framework. The model is shown to capture the subtle mechanical balance occurring within an extended spatially charged zone in the nanopore. The pronounced sensitivity to mechanical forcing offers leads in tuning ion transport by mechanical stimuli. The results presented here provide a promising avenue for the design of tailored membrane functionalities.

  17. Concept for Mars Volcanic Emission Life Scout (3-D)

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This artist's rendition depicts a concept for a Mars orbiter that would scrutinize the martian atmosphere for chemical traces of life or environments supportive of life that might be present anywhere on the planet. The illustration is presented as a three-dimensional stereo view.

    The concept is named the Mars Volcanic Emission and Life Scout, or Marvel. It would equip a Mars orbiter with two types of instruments proven useful in studying Earth's atmosphere from Earth orbit. One, a solar occultation infrared spectrometer, would look sideways through Mars' atmosphere toward the setting or rising Sun for an extremely sensitive reading of what chemicals are in the air that sunlight passes through before hitting the instrument. The other, a submillimeter spectrometer would survey the atmosphere continuously, including during dust storms and polar night, to seek localized surface sources of the chemicals of interest. The infrared spectrometer has very high sensitivity for one chemical of great interest: methane, which is produced by many types of microbes, as well as by some volcanic sources. The submillimeter spectrometer has very high sensitivity for water vapor. Localized concentrations of water vapor in the atmosphere could identify places where subsurface water sources may be venting.

  18. Comparative study to assess whether high sensitive C-reactive protein and carotid intima media thickness improve the predictive accuracy of exercise stress testing for coronary artery disease in perimenopausal women with typical angina.

    PubMed

    Sinha, Dhurjati Prasad; Das, Munna; Banerjee, Amal Kumar; Ahmed, Shageer; Majumdar, Sonali

    2008-02-01

    Anginal symptoms are less predictive of abnormal coronary anatomy in women. The diagnostic accuracy of exercise treadmill test for obstructive coronary artery disease is less in young and middle aged women. High sensitive C-reactive protein has shown a strong and consistent relationship to the risk of incident cardiovascular events. Carotid intima media thickness is a non-invasive marker of atherosclerosis burden and also predicts prognosis in patients with coronary artery disease. We investigated whether incorporation of high sensitive C-reactive protein and carotid intima media thickness along with exercise stress results improved the predictive accuracy in perimenopausal non-diabetic women subset. Fifty perimenopausal non-diabetic patients (age 45 +/- 7 years) presenting with typical angina were subjected to treadmill test (Bruce protocol). Also carotid artery images at both sides of neck were acquired by B-mode ultrasound and carotid intima media thickness were measured. High sensitive C-reactive protein was measured. Of 50 patients, 22 had a positive exercise stress result. Coronary angiography done in all 50 patients revealed coronary artery disease in 10 patients with positive exercise stress result and in 4 patients with negative exercise stress result. Treadmill exercise stress test had a sensitivity of 71.4%, specificity of 66.7% and a negative predictive accuracy of 85.7% in this study group. High sensitive C-reactive protein in patients with documented coronary artery disease was not significantly different from those without coronary artery disease (4.8 +/- 0.9 mg/l versus 3.9 +/- 1.7 mg/l, p=NS). Also carotid intima media thickness was not significantly different between either of the groups with coronary artery disease positivity and negativity respectively (left: 1.25 +/- 0.55 versus 1.20 +/- 0.51 mm, p=NS; right:1.18 +/- 0.54 versus 1.15 +/- 0.41 mm, p=NS). High sensitive C-reactive protein and carotid intima media thickness were not helpful in further adding to the predictability of coronary artery disease in perimenopausal patients with typical angina as assessed by treadmill exercise stress test.

  19. Interaural time sensitivity of high-frequency neurons in the inferior colliculus.

    PubMed

    Yin, T C; Kuwada, S; Sujaku, Y

    1984-11-01

    Recent psychoacoustic experiments have shown that interaural time differences provide adequate cues for lateralizing high-frequency sounds, provided the stimuli are complex and not pure tones. We present here physiological evidence in support of these findings. Neurons of high best frequency in the cat inferior colliculus respond to interaural phase differences of amplitude modulated waveforms, and this response depends upon preservation of phase information of the modulating signal. Interaural phase differences were introduced in two ways: by interaural delays of the entire waveform and by binaural beats in which there was an interaural frequency difference in the modulating waveform. Results obtained with these two methods are similar. Our results show that high-frequency cells can respond to interaural time differences of amplitude modulated signals and that they do so by a sensitivity to interaural phase differences of the modulating waveform.

  20. The mode of sensitization and its influence on allograft outcomes in highly sensitized kidney transplant recipients.

    PubMed

    Redfield, Robert R; Scalea, Joseph R; Zens, Tiffany J; Mandelbrot, Didier A; Leverson, Glen; Kaufman, Dixon B; Djamali, Arjang

    2016-10-01

    We sought to determine whether the mode of sensitization in highly sensitized patients contributed to kidney allograft survival. An analysis of the United Network for Organ Sharing dataset involving all kidney transplants between 1997 and 2014 was undertaken. Highly sensitized adult kidney transplant recipients [panel reactive antibody (PRA) ≥98%] were compared with adult, primary non-sensitized and re-transplant recipients. Kaplan-Meier survival analyses were used to determine allograft survival rates. Cox proportional hazards regression analyses were conducted to determine the association of graft loss with key predictors. Fifty-three percent of highly sensitized patients transplanted were re-transplants. Pregnancy and transfusion were the only sensitizing event in 20 and 5%, respectively. The 10-year actuarial graft survival for highly sensitized recipients was 43.9% compared with 52.4% for non-sensitized patients, P < 0.001. The combination of being highly sensitized by either pregnancy or blood transfusion increased the risk of graft loss by 23% [hazard ratio (HR) 1.230, confidence interval (CI) 1.150-1.315, P < 0.001], and the combination of being highly sensitized from a prior transplant increased the risk of graft loss by 58.1% (HR 1.581, CI 1.473-1.698, P < 0.001). The mode of sensitization predicts graft survival in highly sensitized kidney transplant recipients (PRA ≥98%). Patients who are highly sensitized from re-transplants have inferior graft survival compared with patients who are highly sensitized from other modes of sensitization. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  1. Holographic Moire Contouring

    NASA Astrophysics Data System (ADS)

    Sciammarella, C. A.; Sainov, Ventseslav; Simova, Eli

    1990-04-01

    Theoretical analysis and experimental results on holographic moire contouring (HMC) of difussely reflecting objects are presented. The sensitivity and application constraints of the method are discussed. A high signal-to-noise ratio and contrast of the fringes is achieved through the use of high quality silver halide holographic plates HP-650. A good agreement between theoretical and experimental results is observed.

  2. Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis.

    PubMed

    Iannaccone, Mario; Gili, Sebastiano; De Filippo, Ovidio; D'Amico, Salvatore; Gagliardi, Marco; Bertaina, Maurizio; Mazzilli, Silvia; Rettegno, Sara; Bongiovanni, Federica; Gatti, Paolo; Ugo, Fabrizio; Boccuzzi, Giacomo G; Colangelo, Salvatore; Prato, Silvia; Moretti, Claudio; D'Amico, Maurizio; Noussan, Patrizia; Garbo, Roberto; Hildick-Smith, David; Gaita, Fiorenzo; D'Ascenzo, Fabrizio

    2018-01-01

    Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

  3. Application of upconversion luminescent-magnetic microbeads with weak background noise and facile separation in ochratoxin A detection

    NASA Astrophysics Data System (ADS)

    Liao, Zhenyu; Zhang, Ying; Su, Lin; Chang, Jin; Wang, Hanjie

    2017-02-01

    Ochratoxin A (OTA), the most harmful and abundant ochratoxin, is chemically stable and commonly existed in foodstuffs. In this work, upconversion luminescent-magnetic microbeads (UCLMMs) -based cytometric bead array for OTA detection with a less reagent consumption and high sensitivity has been established and optimized. In UCLMMs, upconversion nanocrystals (UCNs) for optical code present a weak background noise and no spectral cross talk between the encoding signals and target labels under two excitation conditions to improve detection sensitivity. While the superparamagnetic Fe3O4 nanoparticles (Fe3O4 NPs) aim for rapid analysis. The results show that the developed method has a sensitivity of 9.553 ppt below HPLC with a 50-μL sample and can be completed in <2 h with good accuracy and high reproducibility. Therefore, different colors of UCLMMs will become a promising assay platform for multiple mycotoxins after further improvement.

  4. Highly sensitive force sensor based on balloon-like interferometer

    NASA Astrophysics Data System (ADS)

    Wu, Yue; Xiao, Shiying; Xu, Yao; Shen, Ya; Jiang, Youchao; Jin, Wenxing; Yang, Yuguang; Jian, Shuisheng

    2018-07-01

    An all-fiber highly sensitive force sensor based on modal interferometer has been presented and demonstrated. The single-mode fiber (SMF) with coating stripped is designed into a balloon-like shape to form a modal interferometer. Due to the bent SMF, the interference occurs between the core mode and cladding modes. With variation of the force applied to the balloon-like interferometer, the bending diameter changes, which caused the wavelength shift of the modal interference. Thus the measurement of the force variation can be achieved by monitoring the wavelength shift. The performances of the interferometer with different bending diameter are experimentally investigated, and the maximum force sensitivity of 24.9 pm/ μ N can be achieved with the bending diameter 14 mm ranging from 0 μ N to 1464.12 μ N. Furthermore, the proposed fiber sensor exhibits the advantages of easy fabrication and low cost, making it a suitable candidate in the optical fiber sensing field.

  5. Polarization Sensitive Coherent Anti-Stokes Raman Spectroscopy of DCVJ in Doped Polymer

    NASA Astrophysics Data System (ADS)

    Ujj, Laszlo

    2014-05-01

    Coherent Raman Microscopy is an emerging technic and method to image biological samples such as living cells by recording vibrational fingerprints of molecules with high spatial resolution. The race is on to record the entire image during the shortest time possible in order to increase the time resolution of the recorded cellular events. The electronically enhanced polarization sensitive version of Coherent anti-Stokes Raman scattering is one of the method which can shorten the recording time and increase the sharpness of an image by enhancing the signal level of special molecular vibrational modes. In order to show the effectiveness of the method a model system, a highly fluorescence sample, DCVJ in a polymer matrix is investigated. Polarization sensitive resonance CARS spectra are recorded and analyzed. Vibrational signatures are extracted with model independent methods. Details of the measurements and data analysis will be presented. The author gratefully acknowledge the UWF for financial support.

  6. Electron-density-sensitive Line Ratios of Fe XIII– XVI from Laboratory Sources Compared to CHIANTI

    NASA Astrophysics Data System (ADS)

    Weller, M. E.; Beiersdorfer, P.; Soukhanovskii, V. A.; Scotti, F.; LeBlanc, B. P.

    2018-02-01

    We present electron-density-sensitive line ratios for Fe XIII– XVI measured in the spectral wavelength range of 200–440 Å and an electron density range of (1–4) × 1013 cm‑3. The results provide a test at the high-density limit of density-sensitive line ratios useful for astrophysical studies. The measurements were performed on the National Spherical Torus Experiment-Upgrade, where electron densities were measured independently by the laser Thomson scattering diagnostic. Spectra were collected with a flat-field grazing-incidence spectrometer, which provided a spectral resolution of up to 0.3 Å, i.e., high resolution across the broad wavelength range. The response of the instrument was relatively calibrated using spectroscopic techniques in order to improve accuracy. The line ratios are compared to other laboratory sources and the latest version of CHIANTI (8.0.2), and an agreement within 30% is found.

  7. Differential effects of exogenous and endogenous attention on second-order texture contrast sensitivity

    PubMed Central

    Barbot, Antoine; Landy, Michael S.; Carrasco, Marisa

    2012-01-01

    The visual system can use a rich variety of contours to segment visual scenes into distinct perceptually coherent regions. However, successfully segmenting an image is a computationally expensive process. Previously we have shown that exogenous attention—the more automatic, stimulus-driven component of spatial attention—helps extract contours by enhancing contrast sensitivity for second-order, texture-defined patterns at the attended location, while reducing sensitivity at unattended locations, relative to a neutral condition. Interestingly, the effects of exogenous attention depended on the second-order spatial frequency of the stimulus. At parafoveal locations, attention enhanced second-order contrast sensitivity to relatively high, but not to low second-order spatial frequencies. In the present study we investigated whether endogenous attention—the more voluntary, conceptually-driven component of spatial attention—affects second-order contrast sensitivity, and if so, whether its effects are similar to those of exogenous attention. To that end, we compared the effects of exogenous and endogenous attention on the sensitivity to second-order, orientation-defined, texture patterns of either high or low second-order spatial frequencies. The results show that, like exogenous attention, endogenous attention enhances second-order contrast sensitivity at the attended location and reduces it at unattended locations. However, whereas the effects of exogenous attention are a function of the second-order spatial frequency content, endogenous attention affected second-order contrast sensitivity independent of the second-order spatial frequency content. This finding supports the notion that both exogenous and endogenous attention can affect second-order contrast sensitivity, but that endogenous attention is more flexible, benefitting performance under different conditions. PMID:22895879

  8. Highly sensitive bacterial susceptibility test against penicillin using parylene-matrix chip.

    PubMed

    Park, Jong-Min; Kim, Jo-Il; Song, Hyun-Woo; Noh, Joo-Yoon; Kang, Min-Jung; Pyun, Jae-Chul

    2015-09-15

    This work presented a highly sensitive bacterial antibiotic susceptibility test through β-lactamase assay using Parylene-matrix chip. β-lactamases (EC 3.5.2.6) are an important family of enzymes that confer resistance to β-lactam antibiotics by catalyzing the hydrolysis of these antibiotics. Here we present a highly sensitive assay to quantitate β-lactamase-mediated hydrolysis of penicillin into penicilloic acid. Typically, MALDI-TOF mass spectrometry has been used to quantitate low molecular weight analytes and to discriminate them from noise peaks of matrix fragments that occur at low m/z ratios (m/z<500). The β-lactamase assay for the Escherichia coli antibiotic susceptibility test was carried out using Parylene-matrix chip and MALDI-TOF mass spectrometry. The Parylene-matrix chip was successfully used to quantitate penicillin (m/z: [PEN+H](+)=335.1 and [PEN+Na](+)=357.8) and penicilloic acid (m/z: [PA+H](+)=353.1) in a β-lactamase assay with minimal interference of low molecular weight noise peaks. The β-lactamase assay was carried out with an antibiotic-resistant E. coli strain and an antibiotic-susceptible E. coli strain, revealing that the minimum number of E. coli cells required to screen for antibiotic resistance was 1000 cells for the MALDI-TOF mass spectrometry/Parylene-matrix chip assay. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Hybrid organic/inorganic position-sensitive detectors based on PEDOT:PSS/n-Si

    NASA Astrophysics Data System (ADS)

    Javadi, Mohammad; Gholami, Mahdiyeh; Torbatiyan, Hadis; Abdi, Yaser

    2018-03-01

    Various configurations like p-n junctions, metal-semiconductor Schottky barriers, and metal-oxide-semiconductor structures have been widely used in position-sensitive detectors. In this report, we propose a PEDOT:PSS/n-Si heterojunction as a hybrid organic/inorganic configuration for position-sensitive detectors. The influence of the thickness of the PEDOT:PSS layer, the wavelength of incident light, and the intensity of illumination on the device performance are investigated. The hybrid PSD exhibits very high sensitivity (>100 mV/mm), excellent nonlinearity (<3%), and a response correlation coefficient (>0.995) with a response time of <4 ms to the inhomogeneous IR illumination. The presented hybrid configuration also benefits from a straightforward low-temperature fabrication process. These advantages of the PEDOT:PSS/n-Si heterojunction are very promising for developing a new class of position-sensitive detectors based on the hybrid organic/inorganic junctions.

  10. Influence of Functional Groups on the Viscosity of Organic Aerosol.

    PubMed

    Rothfuss, Nicholas E; Petters, Markus D

    2017-01-03

    Organic aerosols can exist in highly viscous or glassy phase states. A viscosity database for organic compounds with atmospherically relevant functional groups is compiled and analyzed to quantify the influence of number and location of functional groups on viscosity. For weakly functionalized compounds the trend in viscosity sensitivity to functional group addition is carboxylic acid (COOH) ≈ hydroxyl (OH) > nitrate (ONO 2 ) > carbonyl (CO) ≈ ester (COO) > methylene (CH 2 ). Sensitivities to group addition increase with greater levels of prior functionalization and decreasing temperature. For carboxylic acids a sharp increase in sensitivity is likely present already at the second addition at room temperature. Ring structures increase viscosity relative to linear structures. Sensitivities are correlated with analogously derived sensitivities of vapor pressure reduction. This may be exploited in the future to predict viscosity in numerical models by piggybacking on schemes that track the evolution of organic aerosol volatility with age.

  11. Recent Developments in Fiber Optics Humidity Sensors.

    PubMed

    Ascorbe, Joaquin; Corres, Jesus M; Arregui, Francisco J; Matias, Ignacio R

    2017-04-19

    A wide range of applications such as health, human comfort, agriculture, food processing and storage, and electronic manufacturing, among others, require fast and accurate measurement of humidity. Sensors based on optical fibers present several advantages over electronic sensors and great research efforts have been made in recent years in this field. The present paper reports the current trends of optical fiber humidity sensors. The evolution of optical structures developed towards humidity sensing, as well as the novel materials used for this purpose, will be analyzed. Well-known optical structures, such as long-period fiber gratings or fiber Bragg gratings, are still being studied towards an enhancement of their sensitivity. Sensors based on lossy mode resonances constitute a platform that combines high sensitivity with low complexity, both in terms of their fabrication process and the equipment required. Novel structures, such as resonators, are being studied in order to improve the resolution of humidity sensors. Moreover, recent research on polymer optical fibers suggests that the sensitivity of this kind of sensor has not yet reached its limit. Therefore, there is still room for improvement in terms of sensitivity and resolution.

  12. Recent Developments in Fiber Optics Humidity Sensors

    PubMed Central

    Ascorbe, Joaquin; Corres, Jesus M.; Arregui, Francisco J.; Matias, Ignacio R.

    2017-01-01

    A wide range of applications such as health, human comfort, agriculture, food processing and storage, and electronic manufacturing, among others, require fast and accurate measurement of humidity. Sensors based on optical fibers present several advantages over electronic sensors and great research efforts have been made in recent years in this field. The present paper reports the current trends of optical fiber humidity sensors. The evolution of optical structures developed towards humidity sensing, as well as the novel materials used for this purpose, will be analyzed. Well-known optical structures, such as long-period fiber gratings or fiber Bragg gratings, are still being studied towards an enhancement of their sensitivity. Sensors based on lossy mode resonances constitute a platform that combines high sensitivity with low complexity, both in terms of their fabrication process and the equipment required. Novel structures, such as resonators, are being studied in order to improve the resolution of humidity sensors. Moreover, recent research on polymer optical fibers suggests that the sensitivity of this kind of sensor has not yet reached its limit. Therefore, there is still room for improvement in terms of sensitivity and resolution. PMID:28422074

  13. Multi-test cervical cancer diagnosis with missing data estimation

    NASA Astrophysics Data System (ADS)

    Xu, Tao; Huang, Xiaolei; Kim, Edward; Long, L. Rodney; Antani, Sameer

    2015-03-01

    Cervical cancer is a leading most common type of cancer for women worldwide. Existing screening programs for cervical cancer suffer from low sensitivity. Using images of the cervix (cervigrams) as an aid in detecting pre-cancerous changes to the cervix has good potential to improve sensitivity and help reduce the number of cervical cancer cases. In this paper, we present a method that utilizes multi-modality information extracted from multiple tests of a patient's visit to classify the patient visit to be either low-risk or high-risk. Our algorithm integrates image features and text features to make a diagnosis. We also present two strategies to estimate the missing values in text features: Image Classifier Supervised Mean Imputation (ICSMI) and Image Classifier Supervised Linear Interpolation (ICSLI). We evaluate our method on a large medical dataset and compare it with several alternative approaches. The results show that the proposed method with ICSLI strategy achieves the best result of 83.03% specificity and 76.36% sensitivity. When higher specificity is desired, our method can achieve 90% specificity with 62.12% sensitivity.

  14. Multiple shooting shadowing for sensitivity analysis of chaotic dynamical systems

    NASA Astrophysics Data System (ADS)

    Blonigan, Patrick J.; Wang, Qiqi

    2018-02-01

    Sensitivity analysis methods are important tools for research and design with simulations. Many important simulations exhibit chaotic dynamics, including scale-resolving turbulent fluid flow simulations. Unfortunately, conventional sensitivity analysis methods are unable to compute useful gradient information for long-time-averaged quantities in chaotic dynamical systems. Sensitivity analysis with least squares shadowing (LSS) can compute useful gradient information for a number of chaotic systems, including simulations of chaotic vortex shedding and homogeneous isotropic turbulence. However, this gradient information comes at a very high computational cost. This paper presents multiple shooting shadowing (MSS), a more computationally efficient shadowing approach than the original LSS approach. Through an analysis of the convergence rate of MSS, it is shown that MSS can have lower memory usage and run time than LSS.

  15. Mimosa-inspired design of a flexible pressure sensor with touch sensitivity.

    PubMed

    Su, Bin; Gong, Shu; Ma, Zheng; Yap, Lim Wei; Cheng, Wenlong

    2015-04-24

    A bio-inspired flexible pressure sensor is generated with high sensitivity (50.17 kPa(-1)), quick responding time (<20 ms), and durable stability (negligible loading-unloading signal changes over 10 000 cycles). Notably, the key resource of surface microstructures upon sensor substrates results from the direct molding of natural mimosa leaves, presenting a simple, environment-friendly and easy scale-up fabrication process for these flexible pressure sensors. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Multidisciplinary Analysis and Optimal Design: As Easy as it Sounds?

    NASA Technical Reports Server (NTRS)

    Moore, Greg; Chainyk, Mike; Schiermeier, John

    2004-01-01

    The viewgraph presentation examines optimal design for precision, large aperture structures. Discussion focuses on aspects of design optimization, code architecture and current capabilities, and planned activities and collaborative area suggestions. The discussion of design optimization examines design sensitivity analysis; practical considerations; and new analytical environments including finite element-based capability for high-fidelity multidisciplinary analysis, design sensitivity, and optimization. The discussion of code architecture and current capabilities includes basic thermal and structural elements, nonlinear heat transfer solutions and process, and optical modes generation.

  17. Mercury Pollution Exploration in Latvia with High-Sensitivity Zeeman Atomic Absorption Spectrometry

    NASA Astrophysics Data System (ADS)

    Bogans, Egils; Gavare, Zanda; Svagere, Anda; Poikane, Rita; Skudra, Jānis

    2011-01-01

    This research presents Hg pollution measurements performed in Latvia with sensitive method using Zeeman AAS analyzer RA-915+ and necessary attachments. Air in Riga city and water samples from a number of rivers and lakes of Latvia were analyzed for presence of low-level Hg concentrations. Ombrotrophic bog peat was analyzed to get insight into long-term trends. Environment in the sites sampled is relatively clean according to the results obtained, but there are local spots of pollution.

  18. Dual channel sensitive detection of hsa-miR-21 based on rolling circle amplification and quantum dots tagging.

    PubMed

    Wangt, Dan-Chen; Hu, Li-Hui; Zhou, Yu-Hui; Huang, Yu-Ting; Li, Xinhua; Zhu, Jun-Jie

    2014-04-01

    An isothermal, highly sensitive and specific assay for the detection of hsa-miR-21 with the integration of QDs tagging and rolling circle amplification was offered. In addition, a dual channel strategy for miRNA detection was proposed: anodic stripping voltammetry (ASV) and fluorescent method were both performed for the final Cd2+ signal readout. The designed strategy exhibited good specificity to hsa-miR-21 and presented comparable detection results by detection methods.

  19. Methods of measurement for semiconductor materials, process control, and devices

    NASA Technical Reports Server (NTRS)

    Bullis, W. M. (Editor)

    1971-01-01

    The development of methods of measurement for semiconductor materials, process control, and devices is discussed. The following subjects are also presented: (1) demonstration of the high sensitivity of the infrared response technique by the identification of gold in a germanium diode, (2) verification that transient thermal response is significantly more sensitive to the presence of voids in die attachment than steady-state thermal resistance, and (3) development of equipment for determining susceptibility of transistors to hot spot formation by the current-gain technique.

  20. The Advanced Gamma-ray Imaging System (AGIS)-Simulation Studies

    NASA Astrophysics Data System (ADS)

    Maier, G.; Buckley, J.; Bugaev, V.; Fegan, S.; Funk, S.; Konopelko, A.; Vassiliev, V. V.

    2008-12-01

    The Advanced Gamma-ray Imaging System (AGIS) is a US-led concept for a next-generation instrument in ground-based very-high-energy gamma-ray astronomy. The most important design requirement for AGIS is a sensitivity of about 10 times greater than current observatories like Veritas, H.E.S.S or MAGIC. We present results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance, collecting area, angular resolution, background rejection, and sensitivity are discussed.

  1. Sensitivity Analysis of Fatigue Crack Growth Model for API Steels in Gaseous Hydrogen.

    PubMed

    Amaro, Robert L; Rustagi, Neha; Drexler, Elizabeth S; Slifka, Andrew J

    2014-01-01

    A model to predict fatigue crack growth of API pipeline steels in high pressure gaseous hydrogen has been developed and is presented elsewhere. The model currently has several parameters that must be calibrated for each pipeline steel of interest. This work provides a sensitivity analysis of the model parameters in order to provide (a) insight to the underlying mathematical and mechanistic aspects of the model, and (b) guidance for model calibration of other API steels.

  2. Diagnosis of clinical samples spotted on FTA cards using PCR-based methods.

    PubMed

    Jamjoom, Manal; Sultan, Amal H

    2009-04-01

    The broad clinical presentation of Leishmaniasis makes the diagnosis of current and past cases of this disease rather difficult. Differential diagnosis is important because diseases caused by other aetiologies and a clinical spectrum similar to that of leishmaniasis (e.g. leprosy, skin cancers and tuberculosis for CL; malaria and schistosomiasis for VL) are often present in endemic areas of endemicity. Presently, a variety of methods have been developed and tested to aid the identification and diagnosis of Leishmania. The advent of the PCR technology has opened new channels for the diagnosis of leishmaniasis in a variety of clinical materials. PCR is a simple, rapid procedure that has been adapted for diagnosis of leishmaniasis. A range of tools is currently available for the diagnosis and identification of leishmaniasis and Leishmania species, respectively. However, none of these diagnostic tools are examined and tested using samples spotted on FTA cards. Three different PCR-based approaches were examined including: kDNA minicircle, Leishmania 18S rRNA gene and PCR-RFLP of Intergenic region of ribosomal protein. PCR primers were designed that sit within the coding sequences of genes (relatively well conserved) but which amplify across the intervening intergenic sequence (relatively variable). These were used in PCR-RFLP on reference isolates of 10 of the most important Leishmania species: L. donovani, L. infantum, L. major & L. tropica. Digestion of PCR products with restriction enzymes produced species-specific restriction patterns allowed discrimination of reference isolates. The kDNA minicircle primers are highly sensitive in diagnosis of both bone marrow and skin smears from FTA cards. Leishmania 18S rRNA gene conserved region is sensitive in identification of bone marrow smear but less sensitive in diagnosing skin smears. The intergenic nested PCR-RFLP using P5 & P6 as well as P1 & P2 newly designed primers showed high level of reproducibility and sensitivity. Though, it was less sensitive than kDNA minicircle primers, but easily discriminated between Leishmania species.

  3. Fiber optic sensor based on Mach-Zehnder interferometer for securing entrance areas of buildings

    NASA Astrophysics Data System (ADS)

    Nedoma, Jan; Fajkus, Marcel; Martinek, Radek; Mec, Pavel; Novak, Martin; Bednarek, Lukas; Vasinek, Vladimir

    2017-10-01

    Authors of this article focused on the utilization of fiber optic sensors based on interferometric measurements for securing entrance areas of buildings such as windows and doors. We described the implementation of the fiber-optic interferometer (type Mach-Zehnder) into the window frame or door, sensor sensitivity, analysis of the background noise and methods of signal evaluation. The advantage of presented solution is the use of standard telecommunication fiber standard G.652.D, high sensitivity, immunity of sensor to electromagnetic interference (EMI) and passivity of the sensor regarding power supply. Authors implemented the Graphical User Interface (GUI) which offers the possibility of remote monitoring presented sensing solution.

  4. Ultra-low-noise preamplifier for condenser microphones.

    PubMed

    Starecki, Tomasz

    2010-12-01

    The paper presents the design of a low-noise preamplifier dedicated for condenser measurement microphones used in high sensitivity applications, in which amplifier noise is the main factor limiting sensitivity of the measurements. In measurement microphone preamplifiers, the dominant source of noise at lower frequencies is the bias resistance of the input stage. In the presented solution, resistors were connected to the input stage by means of switches. The switches are opened during measurements, which disconnects the resistors from the input stage and results in noise reduction. Closing the switches allows for fast charging of the microphone capacitance. At low frequencies the noise of the designed preamplifier is a few times lower in comparison to similar, commercially available instruments.

  5. DSMC Simulations of Apollo Capsule Aerodynamics for Hypersonic Rarefied Conditions

    NASA Technical Reports Server (NTRS)

    Moss, James N.; Glass, Christopher E.; Greene, Francis A.

    2006-01-01

    Direct simulation Monte Carlo DSMC simulations are performed for the Apollo capsule in the hypersonic low density transitional flow regime. The focus is on ow conditions similar to that experienced by the Apollo Command Module during the high altitude portion of its reentry Results for aerodynamic forces and moments are presented that demonstrate their sensitivity to rarefaction that is for free molecular to continuum conditions. Also aerodynamic data are presented that shows their sensitivity to a range of reentry velocity encompasing conditions that include reentry from low Earth orbit lunar return and Mars return velocities to km/s. The rarefied results are anchored in the continuum regime with data from Navier Stokes simulations

  6. Post-trial apomorphine at an autoreceptor dose level can eliminate apomorphine conditioning and sensitization: support for the critical role of dopamine in re-consolidation.

    PubMed

    Carrera, Marinete Pinheiro; Carey, Robert J; Cruz Dias, Flávia Regina; dos Santos Sampaio, Maria de Fátima; de Matos, Liana Wermelinger

    2013-01-01

    Re-exposure to conditioned drug stimuli triggers re-consolidation processes. In the present study post-trial apomorphine treatments were administered in order to interact with the re-consolidation of an apomorphine conditioned/sensitized locomotor response. A low (0.05 mg/kg) and a high (2.0mg/kg) dose were used to inhibit or to enhance dopamine activity, respectively. Initially, groups received 5 daily apomorphine (2.0mg/kg)/vehicle treatments either paired or unpaired to open-field placement. The paired treatments generated a progressive locomotor response. Subsequently, all groups received a 5 min non-drug test for conditioning and a conditioned locomotor response was observed in the paired group. The groups received another apomorphine (2.0mg/kg)/vehicle treatment as a re-induction treatment. At this stage the post-trial protocol was initiated. One set of paired, unpaired and vehicle groups were given a low dose of apomorphine (0.05 mg/kg) post-trial; another set received a high dose of apomorphine (2.0mg/kg) post-trial. The remaining group set received vehicle post-trial. The low dose post-trial treatment eliminated the conditioned and sensitized locomotor response and the high dose post-trial treatment enhanced the conditioned and sensitized locomotor response. The efficacy of the post-trial apomorphine treatments to modify the conditioned and the sensitized response after a brief non-drug exposure to test cues supports the proposition that exteroceptive cues control conditioning and sensitization and that the interoceptive drug cues make little or no associational contribution to apomorphine conditioning and sensitization. In addition, the findings point to the importance of dopamine activation in both the acquisition and re-consolidation of conditioning processes. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Sensitivity of glaciation in the arid subtropical Andes to changes in temperature, precipitation, and solar radiation

    NASA Astrophysics Data System (ADS)

    Vargo, L. J.; Galewsky, J.; Rupper, S.; Ward, D. J.

    2018-04-01

    The subtropical Andes (18.5-27 °S) have been glaciated in the past, but are presently glacier-free. We use idealized model experiments to quantify glacier sensitivity to changes in climate in order to investigate the climatic drivers of past glaciations. We quantify the equilibrium line altitude (ELA) sensitivity (the change in ELA per change in climate) to temperature, precipitation, and shortwave radiation for three distinct climatic regions in the subtropical Andes. We find that in the western cordillera, where conditions are hyper-arid with the highest solar radiation on Earth, ELA sensitivity is as high as 34 m per % increase in precipitation, and 70 m per % decrease in shortwave radiation. This is compared with the eastern cordillera, where precipitation is the highest of the three regions, and ELA sensitivity is only 10 m per % increase in precipitation, and 25 m per % decrease in shortwave radiation. The high ELA sensitivity to shortwave radiation highlights the influence of radiation on mass balance of high elevation and low-latitude glaciers. We also consider these quantified ELA sensitivities in context of previously dated glacial deposits from the regions. Our results suggest that glaciation of the humid eastern cordillera was driven primarily by lower temperatures, while glaciations of the arid Altiplano and western cordillera were also influenced by increases in precipitation and decreases in shortwave radiation. Using paleoclimate records from the timing of glaciation, we find that glaciation of the hyper-arid western cordillera can be explained by precipitation increases of 90-160% (1.9-2.6× higher than modern), in conjunction with associated decreases in shortwave radiation of 7-12% and in temperature of 3.5 °C.

  8. Examining the relationship between free recall and immediate serial recall: Similar patterns of rehearsal and similar effects of word length, presentation rate, and articulatory suppression.

    PubMed

    Bhatarah, Parveen; Ward, Geoff; Smith, Jessica; Hayes, Louise

    2009-07-01

    In five experiments, rehearsal and recall phenomena were examined using the free recall and immediate serial recall (ISR) tasks. In Experiment 1, participants were presented with lists of eight words, were precued or postcued to respond using free recall or ISR, and rehearsed out loud during presentation. The patterns of rehearsal were similar in all the conditions, and there was little difference between recall in the precued and postcued conditions. In Experiment 2, both free recall and ISR were sensitive to word length and presentation rate and showed similar patterns of rehearsal. In Experiment 3, both tasks were sensitive to word length and articulatory suppression. The word length effects generalized to 6-item (Experiment 4) and 12-item (Experiment 5) lists. These findings suggest that the two tasks are underpinned by highly similar rehearsal and recall processes.

  9. EUV lithography for 30nm half pitch and beyond: exploring resolution, sensitivity, and LWR tradeoffs

    NASA Astrophysics Data System (ADS)

    Putna, E. Steve; Younkin, Todd R.; Chandhok, Manish; Frasure, Kent

    2009-03-01

    The International Technology Roadmap for Semiconductors (ITRS) denotes Extreme Ultraviolet (EUV) lithography as a leading technology option for realizing the 32nm half-pitch node and beyond. Readiness of EUV materials is currently one high risk area according to assessments made at the 2008 EUVL Symposium. The main development issue regarding EUV resist has been how to simultaneously achieve high sensitivity, high resolution, and low line width roughness (LWR). This paper describes the strategy and current status of EUV resist development at Intel Corporation. Data is presented utilizing Intel's Micro-Exposure Tool (MET) examining the feasibility of establishing a resist process that simultaneously exhibits <=30nm half-pitch (HP) L/S resolution at <=10mJ/cm2 with <=4nm LWR.

  10. EUV lithography for 22nm half pitch and beyond: exploring resolution, LWR, and sensitivity tradeoffs

    NASA Astrophysics Data System (ADS)

    Putna, E. Steve; Younkin, Todd R.; Caudillo, Roman; Chandhok, Manish

    2010-04-01

    The International Technology Roadmap for Semiconductors (ITRS) denotes Extreme Ultraviolet (EUV) lithography as a leading technology option for realizing the 22nm half pitch node and beyond. Readiness of EUV materials is currently one high risk area according to recent assessments made at the 2009 EUVL Symposium. The main development issue regarding EUV resist has been how to simultaneously achieve high sensitivity, high resolution, and low line width roughness (LWR). This paper describes the strategy and current status of EUV resist development at Intel Corporation. Data collected utilizing Intel's Micro-Exposure Tool (MET) is presented in order to examine the feasibility of establishing a resist process that simultaneously exhibits <=22nm half-pitch (HP) L/S resolution at <= 12.5mJ/cm2 with <= 4nm LWR.

  11. Towards an integrated optofluidic system for highly sensitive detection of antibiotics in seawater incorporating bimodal waveguide photonic biosensors and complex, active microfluidics

    NASA Astrophysics Data System (ADS)

    Szydzik, C.; Gavela, A. F.; Roccisano, J.; Herranz de Andrés, S.; Mitchell, A.; Lechuga, L. M.

    2016-12-01

    We present recent results on the realisation and demonstration of an integrated optofluidic lab-on-a-chip measurement system. The system consists of an integrated on-chip automated microfluidic fluid handling subsystem, coupled with bimodal nano-interferometer waveguide technology, and is applied in the context of detection of antibiotics in seawater. The bimodal waveguide (BMWG) is a highly sensitive label-free biosensor. Integration of complex microfluidic systems with bimodal waveguide technology enables on-chip sample handling and fluid processing capabilities and allows for significant automation of experimental processes. The on-chip fluid-handling subsystem is realised through the integration of pneumatically actuated elastomer pumps and valves, enabling high temporal resolution sample and reagent delivery and facilitating multiplexed detection processes.

  12. Sugar nanowires based on cyclodextrin on quartz crystal microbalance for gas sensing with ultra-high sensitivity

    NASA Astrophysics Data System (ADS)

    Asano, Atsushi; Maeyoshi, Yuta; Watanabe, Shogo; Saeki, Akinori; Sugimoto, Masaki; Yoshikawa, Masahito; Nanto, Hidehito; Tsukuda, Satoshi; Tanaka, Shun-Ichiro; Seki, Shu

    2013-03-01

    Cyclodextrins (CDs), hosting selectively a wide range of guest molecules in their hydrophobic cavity, were directly fabricated into 1-dimensional nanostructures with extremely wide surface area by single particle nanofabrication technique in the present paper. The copolymers of acrylamide and mono(6-allyl)-β-CD were synthesized, and the crosslinking reaction of the polymer alloys with poly(4-bromostyrene) (PBrS) in SPNT gave nanowires on the quarts substrate with high number density of 5×109 cm-2. Quartz crystal microbalance (QCM) measurement suggested 320 fold high sensitivity for formic acid vapor adsorption in the nanowire fabricated surfaces compared with that in the thin solid film of PBrS, due to the incorporation of CD units and extremely wide surface area of the nanowires.

  13. Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arauzo, A.; Guerrero, E.; Urtizberea, A.

    2012-06-15

    A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed,more » and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.« less

  14. Dark-field imaging in coronary atherosclerosis.

    PubMed

    Hetterich, Holger; Webber, Nicole; Willner, Marian; Herzen, Julia; Birnbacher, Lorenz; Auweter, Sigrid; Schüller, Ulrich; Bamberg, Fabian; Notohamiprodjo, Susan; Bartsch, Harald; Wolf, Johannes; Marschner, Mathias; Pfeiffer, Franz; Reiser, Maximilian; Saam, Tobias

    2017-09-01

    Dark-field imaging based on small angle X-ray scattering has been shown to be highly sensitive for microcalcifications, e.g. in breast tissue. We hypothesized (i) that high signal areas in dark-field imaging of atherosclerotic plaque are associated with microcalcifications and (ii) that dark-field imaging is more sensitive for microcalcifications than attenuation-based imaging. Fifteen coronary artery specimens were examined at an experimental set-up consisting of X-ray tube (40kV), grating-interferometer and detector. Tomographic dark-field-, attenuation-, and phase-contrast data were simultaneously acquired. Histopathology served as standard of reference. To explore the potential of dark field imaging in a full-body CT system, simulations were carried out with spherical calcifications of different sizes to simulate small and intermediate microcalcifications. Microcalcifications were present in 10/10 (100%) cross-sections with high dark-field signal and without evidence of calcifications in attenuation- or phase contrast. In positive controls with high signal areas in all three modalities, 10/10 (100%) cross-sections showed macrocalcifications. In negative controls without high signal areas, no calcifications were detected. Simulations showed that the microcalcifications generate substantially higher dark-field than attenuation signal. Dark-field imaging is highly sensitive for microcalcifications in coronary atherosclerotic plaque and might provide complementary information in the assessment of plaque instability. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Magneto-optical detection of the relaxation dynamics of alloy nanoparticles with a high-stability magnetic circular dichroism setup

    NASA Astrophysics Data System (ADS)

    Cavigli, L.; de Julián Fernández, C.; Gatteschi, D.; Gurioli, M.; Sangregorio, C.; Mattei, G.; Mazzoldi, P.; Bogani, L.

    2007-09-01

    We present a versatile high-stability and high-sensitivity magneto-optical setup that allows transmission and reflection measurements at high fields and low temperatures. We apply the technique to measure the decay in time of the magnetization of highly monodisperse 3.3 nm Co33Ni67 alloy nanoparticles embedded in a silica host. We demonstrate the possibility of observing the dynamics of the magnetization over a macroscopic timescale in dilute samples, where other techniques are unavailable.

  16. Early diagnosis of acute coronary syndrome.

    PubMed

    Katus, Hugo; Ziegler, André; Ekinci, Okan; Giannitsis, Evangelos; Stough, Wendy Gattis; Achenbach, Stephan; Blankenberg, Stefan; Brueckmann, Martina; Collinson, Paul; Comaniciu, Dorin; Crea, Filippo; Dinh, Wilfried; Ducrocq, Grégory; Flachskampf, Frank A; Fox, Keith A A; Friedrich, Matthias G; Hebert, Kathy A; Himmelmann, Anders; Hlatky, Mark; Lautsch, Dominik; Lindahl, Bertil; Lindholm, Daniel; Mills, Nicholas L; Minotti, Giorgio; Möckel, Martin; Omland, Torbjørn; Semjonow, Véronique

    2017-11-01

    The diagnostic evaluation of acute chest pain has been augmented in recent years by advances in the sensitivity and precision of cardiac troponin assays, new biomarkers, improvements in imaging modalities, and release of new clinical decision algorithms. This progress has enabled physicians to diagnose or rule-out acute myocardial infarction earlier after the initial patient presentation, usually in emergency department settings, which may facilitate prompt initiation of evidence-based treatments, investigation of alternative diagnoses for chest pain, or discharge, and permit better utilization of healthcare resources. A non-trivial proportion of patients fall in an indeterminate category according to rule-out algorithms, and minimal evidence-based guidance exists for the optimal evaluation, monitoring, and treatment of these patients. The Cardiovascular Round Table of the ESC proposes approaches for the optimal application of early strategies in clinical practice to improve patient care following the review of recent advances in the early diagnosis of acute coronary syndrome. The following specific 'indeterminate' patient categories were considered: (i) patients with symptoms and high-sensitivity cardiac troponin <99th percentile; (ii) patients with symptoms and high-sensitivity troponin <99th percentile but above the limit of detection; (iii) patients with symptoms and high-sensitivity troponin >99th percentile but without dynamic change; and (iv) patients with symptoms and high-sensitivity troponin >99th percentile and dynamic change but without coronary plaque rupture/erosion/dissection. Definitive evidence is currently lacking to manage these patients whose early diagnosis is 'indeterminate' and these areas of uncertainty should be assigned a high priority for research. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  17. Development of Fluorescent Polymerization-based Signal Amplification for Sensitive and Non-enzymatic Biodetection in Antibody Microarrays

    PubMed Central

    Avens, Heather J.; Bowman, Christopher N.

    2009-01-01

    Antibody microarrays are a critical tool for proteomics, requiring broad, highly sensitive detection of numerous low abundance biomarkers. Fluorescent polymerization-based amplification (FPBA) is presented as a novel, non-enzymatic signal amplification method that takes advantage of the chain-reaction nature of radical polymerization to achieve a highly amplified fluorescent response. A streptavidin-eosin conjugate localizes eosin photoinitiators for polymerization on the chip where biotinylated target protein is bound. The chip is contacted with acrylamide as a monomer, N-methyldiethanolamine as a coinitiator and yellow/green fluorescent nanoparticles (NPs) which, upon initiation, combine to form a macroscopically visible and highly fluorescent film. The rapid polymerization kinetics and the presence of cross-linker favor entrapment of the fluorescent NPs in the polymer, enabling highly sensitive fluorescent biodetection. This method is demonstrated as being appropriate for antibody microarrays and is compared to detection approaches which utilize streptavidin-FITC (SA-FITC) and streptavidin-labeled yellow/green NPs (SA-NPs). It is found that FPBA is able to detect 0.16 (+/− 0.01) biotin-antibody/µm2 (or 40 zeptomole surface-bound target molecules), while SA-FITC has a limit of detection of 31 (+/− 1) biotin-antibody/µm2 and SA-NPs fail to achieve any significant signal under the conditions evaluated here. Further, FPBA in conjunction with fluorescent stereomicroscopy yields equal or better sensitivity compared to fluorescent detection of SA-eosin using a much more costly microarray scanner. By facilitating highly sensitive detection, FPBA is expected to enable detection of low abundance antigens and also make possible a transition towards less expensive fluorescence detection instrumentation. PMID:19508906

  18. High levels of wheel running protect against behavioral sensitization to cocaine.

    PubMed

    Renteria Diaz, Laura; Siontas, Dora; Mendoza, Jose; Arvanitogiannis, Andreas

    2013-01-15

    Although there is no doubt that the direct action of stimulant drugs on the brain is necessary for sensitization to their behavioral stimulating effects, several experiments indicate that drug action is often not sufficient to produce sensitization. There is considerable evidence that many individual characteristics and experiential variables can modulate the behavioral and neural changes that are seen following repeated exposure to stimulant drugs. In the work presented here, we examined whether chronic wheel running would modulate behavioral sensitization to cocaine, and whether any such influence was contingent on individual differences in wheel running. We found that a 5- or 10-week experience with wheel running protects against behavioral sensitization to cocaine but only in animals with a natural tendency to run the most. Understanding the mechanism underlying the modulating effect of wheel running on behavioral sensitization may have important implications for future studies on the link between drug-induced behavioral and neural adaptations. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Sensitivity and specificity of clinical, histologic, and immunologic features in the diagnosis of paraneoplastic pemphigus.

    PubMed

    Joly, P; Richard, C; Gilbert, D; Courville, P; Chosidow, O; Roujeau, J C; Beylot-Barry, M; D'incan, M; Martel, P; Lauret, P; Tron, F

    2000-10-01

    Paraneoplastic pemphigus (PNP) is an autoimmune blistering disease characterized by the production of autoantibodies mainly directed against proteins of the plakin family. An overlapping distribution of autoantibody specificities has been recently reported between PNP, pemphigus vulgaris (PV), and pemphigus foliaceus (PF), which suggests a relationship between the different types of pemphigus. Our purpose was to evaluate the sensitivity and the specificity of clinical, histologic, and immunologic features in the diagnosis of PNP. The clinical, histologic, and immunologic features of 22 PNP patients were retrospectively reviewed and compared with those of 81 PV and PF patients without neoplasia and of 8 PV and 4 PF patients with various neoplasms. One clinical and 2 biologic features had both high sensitivity (82%-86%) and high specificity (83%-100%) whatever the control group considered: (1) association with a lymphoproliferative disorder, (2) indirect immunofluorescence (IIF) labeling of rat bladder, and (3) recognition of the envoplakin and/or periplakin bands in immunoblotting. Two clinicopathologic and two biologic features had high specificity (87%-100%) but poor sensitivity (27%-59%): (1) clinical presentation associating erosive oral lesions with erythema multiforme-like, bullous pemphigoid-like, or lichen planus-like cutaneous lesions; (2) histologic picture of suprabasal acantholysis with keratinocyte necrosis, interface changes, or lichenoid infiltrate; (3) presence of both anti-epithelial cell surface and anti-basement membrane zone antibodies by IIF; and (4) recognition of the desmoplakin I and/or BPAG1 bands in immunoblotting. Interestingly, 45% of patients with PNP presented initially with isolated oral erosions that were undistinguishable from those seen in PV patients, and 27% had histologic findings of only suprabasal acantholysis, which was in accordance with the frequent detection of anti-desmoglein 3 antibodies in PNP sera. The association with a lymphoproliferative disorder, the IIF labeling of rat bladder, and the immunoblotting recognition of envoplakin and/or periplakin are both sensitive and specific features in the diagnosis of PNP.

  20. Proteins associated with EGFR-TKIs resistance in patients with non-small cell lung cancer revealed by mass spectrometry.

    PubMed

    Yang, Shaoyu; Chen, Xueqin; Pan, Yuelong; Yu, Jiekai; Li, Xin; Ma, Shenglin

    2016-11-01

    The present study aimed to identify potential serum biomarkers for predicting the clinical outcomes of patients with advanced non-small cell lung cancer (NSCLC) treated with epidermal growth factor receptor tyrosine kinase inhibitors (EGFR‑TKIs). A total of 61 samples were collected and analyzed using the integrated approach of magnetic bead‑based weak cation exchange chromatography and matrix‑assisted laser desorption/ionization‑time of flight‑mass spectrometry. The Zhejiang University Protein Chip Data Analysis system was used to identify the protein spectra of patients that are resistant and sensitive to EGFR‑TKIs. Furthermore, a support vector machine was used to construct a predictive model with high accuracy. The model was trained using 46 samples and tested with the remaining 15 samples. In addition, the ExPASy Bioinformatics Resource Portal was used to search potential candidate proteins for peaks in the predictive model. Seven mass/charge (m/z) peaks at 3,264, 9,156, 9,172, 3,964, 9,451, 4,295 and 3,983 Da, were identified as significantly different peaks between the EGFR‑TKIs sensitive and resistant groups. A predictive model was generated with three protein peaks at 3,264, 9,451 and 4,295 Da (m/z). This three‑peak model was capable of distinguishing EGFR‑TKIs resistant patients from sensitive patients with a specificity of 80% and a sensitivity of 80.77%. Furthermore, in a blind test, this model exhibited a high specificity (80%) and a high sensitivity (90%). Apelin, TYRO protein tyrosine kinase‑binding protein and big endothelin‑1 may be potential candidates for the proteins identified with an m/z of 3,264, 9,451 and 4,295 Da, respectively. The predictive model used in the present study may provide an improved understanding of the pathogenesis of NSCLC, and may provide insights for the development of TKI treatment plans tailored to specific patients.

Top