NASA Astrophysics Data System (ADS)
Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John
2016-09-01
DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.
Privacy Preserving Sequential Pattern Mining in Data Stream
NASA Astrophysics Data System (ADS)
Huang, Qin-Hua
The privacy preserving data mining technique researches have gained much attention in recent years. For data stream systems, wireless networks and mobile devices, the related stream data mining techniques research is still in its' early stage. In this paper, an data mining algorithm dealing with privacy preserving problem in data stream is presented.
Satínský, Dalibor; Huclová, Jitka; Ferreira, Raquel L C; Montenegro, Maria Conceição B S M; Solich, Petr
2006-02-13
The porous monolithic columns show high performance at relatively low pressure. The coupling of short monoliths with sequential injection technique (SIA) results in a new approach to implementation of separation step to non-separation low-pressure method. In this contribution, a new separation method for simultaneous determination of ambroxol, methylparaben and benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith SpeedROD RP-18e, 50-4.6 mm column with 10 mm precolumn and a FIAlab 3000 system with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-tetrahydrofuran-0.05M acetic acid (10:10:90, v/v/v), pH 3.75 adjusted with triethylamine, flow rate 0.48 mlmin(-1), UV-detection was at 245 nm. The analysis time was <11 min. A new SIC method was validated and compared with HPLC. The method was found to be useful for the routine analysis of the active compounds ambroxol and preservatives (methylparaben or benzoic acid) in various pharmaceutical syrups and drops.
Neoadjuvant therapy for organ preservation in head and neck cancer.
Urba, S G; Wolf, G T; Bradford, C R; Thornton, A F; Eisbruch, A; Terrell, J E; Carpenter, V; Miller, T; Tang, G; Strawderman, M
2000-12-01
We designed two sequential trials of induction chemotherapy followed by definitive radiation in patients with potentially resectable head and neck cancer to determine whether organ preservation is feasible without apparent compromise of survival Study Design Both trials were Phase II studies. Two clinical trials were conducted sequentially at the University of Michigan. Fifty-two patients enrolled in the first study and were treated with a planned three cycles of carboplatin and 5-fluorouracil. Patients who achieved at least 50% reduction in the size of the primary tumor received definitive radiation therapy, to a dose of 6600 to 7380 cGy. Patients with minimal response or progression had immediate salvage surgery. Thirty-seven patients enrolled in the second trial, in which the chemotherapy consisted of carboplatin, 5-fluororuracil, and leukovorin. Responders were treated with accelerated radiation therapy, to a total dose of 7120 cGy delivered in 41 fractions over 5.5 weeks. Toxicity and response were similar in both trials; therefore, the results are reported first separately and then combined for all 89 patients. Tumor sites included: oropharynx, 55 patients; hypopharynx, 34 patients. Eighty-three percent of patients tolerated all three cycles of chemotherapy and toxicity was mild. Response to chemotherapy was: 48% complete response at the primary tumor site, and 34% partial response at the primary tumor site. Initial organ preservation at individual tumor sites was: oropharynx, 58%; hypopharynx, 59%. Median survival was 28 months, and survival at 3 and 5 years was 40% and 24%, respectively. These two regimens were well tolerated, and survival did not appear to be compromised by organ preservation treatment compared with historical controls. This approach warrants further investigation, particularly in those patients for whom surgery could be functionally debilitating.
Bohn, Justin; Eddings, Wesley; Schneeweiss, Sebastian
2017-03-15
Distributed networks of health-care data sources are increasingly being utilized to conduct pharmacoepidemiologic database studies. Such networks may contain data that are not physically pooled but instead are distributed horizontally (separate patients within each data source) or vertically (separate measures within each data source) in order to preserve patient privacy. While multivariable methods for the analysis of horizontally distributed data are frequently employed, few practical approaches have been put forth to deal with vertically distributed health-care databases. In this paper, we propose 2 propensity score-based approaches to vertically distributed data analysis and test their performance using 5 example studies. We found that these approaches produced point estimates close to what could be achieved without partitioning. We further found a performance benefit (i.e., lower mean squared error) for sequentially passing a propensity score through each data domain (called the "sequential approach") as compared with fitting separate domain-specific propensity scores (called the "parallel approach"). These results were validated in a small simulation study. This proof-of-concept study suggests a new multivariable analysis approach to vertically distributed health-care databases that is practical, preserves patient privacy, and warrants further investigation for use in clinical research applications that rely on health-care databases. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Carretti, Barbara; Lanfranchi, Silvia; Mammarella, Irene C
2013-01-01
Earlier research showed that visuospatial working memory (VSWM) is better preserved in Down syndrome (DS) than verbal WM. Some differences emerged, however, when VSWM performance was broken down into its various components, and more recent studies revealed that the spatial-simultaneous component of VSWM is more impaired than the spatial-sequential one. The difficulty of managing more than one item at a time is also evident when the information to be recalled is structured. To further analyze this issue, we investigated the advantage of material being structured in spatial-simultaneous and spatial-sequential tasks by comparing the performance of a group of individuals with DS and a group of typically-developing children matched for mental age. Both groups were presented with VSWM tasks in which both the presentation format (simultaneous vs. sequential) and the type of configuration (pattern vs. random) were manipulated. Findings indicated that individuals with DS took less advantage of the pattern configuration in the spatial-simultaneous task than TD children; in contrast, the two groups' performance did not differ in the pattern configuration of the spatial-sequential task. Taken together, these results confirmed difficulties relating to the spatial-simultaneous component of VSWM in individuals with DS, supporting the importance of distinguishing between different components within this system. The findings are discussed in terms of factors influencing this specific deficit. Copyright © 2012 Elsevier Ltd. All rights reserved.
3D prostate MR-TRUS non-rigid registration using dual optimization with volume-preserving constraint
NASA Astrophysics Data System (ADS)
Qiu, Wu; Yuan, Jing; Fenster, Aaron
2016-03-01
We introduce an efficient and novel convex optimization-based approach to the challenging non-rigid registration of 3D prostate magnetic resonance (MR) and transrectal ultrasound (TRUS) images, which incorporates a new volume preserving constraint to essentially improve the accuracy of targeting suspicious regions during the 3D TRUS guided prostate biopsy. Especially, we propose a fast sequential convex optimization scheme to efficiently minimize the employed highly nonlinear image fidelity function using the robust multi-channel modality independent neighborhood descriptor (MIND) across the two modalities of MR and TRUS. The registration accuracy was evaluated using 10 patient images by calculating the target registration error (TRE) using manually identified corresponding intrinsic fiducials in the whole prostate gland. We also compared the MR and TRUS manually segmented prostate surfaces in the registered images in terms of the Dice similarity coefficient (DSC), mean absolute surface distance (MAD), and maximum absolute surface distance (MAXD). Experimental results showed that the proposed method with the introduced volume-preserving prior significantly improves the registration accuracy comparing to the method without the volume-preserving constraint, by yielding an overall mean TRE of 2:0+/-0:7 mm, and an average DSC of 86:5+/-3:5%, MAD of 1:4+/-0:6 mm and MAXD of 6:5+/-3:5 mm.
High Accuracy Human Activity Recognition Based on Sparse Locality Preserving Projections.
Zhu, Xiangbin; Qiu, Huiling
2016-01-01
Human activity recognition(HAR) from the temporal streams of sensory data has been applied to many fields, such as healthcare services, intelligent environments and cyber security. However, the classification accuracy of most existed methods is not enough in some applications, especially for healthcare services. In order to improving accuracy, it is necessary to develop a novel method which will take full account of the intrinsic sequential characteristics for time-series sensory data. Moreover, each human activity may has correlated feature relationship at different levels. Therefore, in this paper, we propose a three-stage continuous hidden Markov model (TSCHMM) approach to recognize human activities. The proposed method contains coarse, fine and accurate classification. The feature reduction is an important step in classification processing. In this paper, sparse locality preserving projections (SpLPP) is exploited to determine the optimal feature subsets for accurate classification of the stationary-activity data. It can extract more discriminative activities features from the sensor data compared with locality preserving projections. Furthermore, all of the gyro-based features are used for accurate classification of the moving data. Compared with other methods, our method uses significantly less number of features, and the over-all accuracy has been obviously improved.
High Accuracy Human Activity Recognition Based on Sparse Locality Preserving Projections
2016-01-01
Human activity recognition(HAR) from the temporal streams of sensory data has been applied to many fields, such as healthcare services, intelligent environments and cyber security. However, the classification accuracy of most existed methods is not enough in some applications, especially for healthcare services. In order to improving accuracy, it is necessary to develop a novel method which will take full account of the intrinsic sequential characteristics for time-series sensory data. Moreover, each human activity may has correlated feature relationship at different levels. Therefore, in this paper, we propose a three-stage continuous hidden Markov model (TSCHMM) approach to recognize human activities. The proposed method contains coarse, fine and accurate classification. The feature reduction is an important step in classification processing. In this paper, sparse locality preserving projections (SpLPP) is exploited to determine the optimal feature subsets for accurate classification of the stationary-activity data. It can extract more discriminative activities features from the sensor data compared with locality preserving projections. Furthermore, all of the gyro-based features are used for accurate classification of the moving data. Compared with other methods, our method uses significantly less number of features, and the over-all accuracy has been obviously improved. PMID:27893761
Perosky, Joseph E; Khoury, Basma M; Jenks, Terese N; Ward, Ferrous S; Cortright, Kai; Meyer, Bethany; Barton, David K; Sinder, Benjamin P; Marini, Joan C; Caird, Michelle S; Kozloff, Kenneth M
2016-12-01
Sclerostin antibody has demonstrated a bone-forming effect in pre-clinical models of osteogenesis imperfecta, where mutations in collagen or collagen-associated proteins often result in high bone fragility in pediatric patients. Cessation studies in osteoporotic patients have demonstrated that sclerostin antibody, like intermittent PTH treatment, requires sequential anti-resorptive therapy to preserve the anabolic effects in adult populations. However, the persistence of anabolic gains from either drug has not been explored clinically in OI, or in any animal model. To determine whether cessation of sclerostin antibody therapy in a growing OI skeleton requires sequential anti-resorptive treatment to preserve anabolic gains in bone mass, we treated 3week old Brtl/+ and wild type mice for 5weeks with SclAb, and then withdrew treatment for an additional 6weeks. Trabecular bone loss was evident following cessation, but was preserved in a dose-dependent manner with single administration of pamidronate at the time of cessation. In vivo longitudinal near-infrared optical imaging of cathepsin K activation in the proximal tibia suggests an anti-resorptive effect of both SclAb and pamidronate which is reversed after three weeks of cessation. Cortical bone was considerably less susceptible to cessation effects, and showed no structural or functional deficits in the absence of pamidronate during this cessation period. In conclusion, while SclAb induces a considerable anabolic gain in the rapidly growing Brtl/+ murine model of OI, a single sequential dose of antiresorptive drug is required to maintain bone mass at trabecular sites for 6weeks following cessation. Copyright © 2016 Elsevier Inc. All rights reserved.
Snabaitis, A K; Chambers, D
1999-11-27
Polarized arrest, induced by tetrodotoxin (TTX) at an optimal concentration of 22 micromol/L, has been shown to reduce ionic imbalance and improve myocardial preservation compared with hyperkalemic (depolarized) arrest. Additional pharmacologic manipulation of ionic changes (involving inhibition of Na+ influx by the Na+/H+ exchanger [HOE694] and Na+/K+/2Cl- cotransporter [furosemide], and calcium desensitization [BDM]) may further improve long-term preservation. In this study, we (i) established optimal concentrations of each drug, (ii) determined additive effects of optimal concentrations of each drug and (iii) compared our optimal preservation solution to an established depolarizing cardioplegia (St Thomas' Hospital solution No 2: STH2) used during long-term hypothermic storage for clinical transplantation. The isolated working rat heart, perfused with Krebs Henseleit (KH) buffer was used; cardiac function was measured after 20 min aerobic working mode perfusion. The hearts (n=6/group) were arrested with a 2 ml infusion (for 30 sec) of the polarizing (control) solution (22 micromol/L TTX in KH) or control+drug and subjected to 5 hr or 8 hr of storage at 7.5 degrees C in the arresting solution. Postischemic function during reperfusion was measured (expressed as percentage of preischemic function). Dose-response studies established optimal concentrations of HOE694 (10 micromol/L), furosemide (1.0 micromol/L) and BDM (30 mmol/L) in the polarizing (control) solution. Sequential addition to the control solution (Group I) of optimal concentrations of HOE694 (Group II), furosemide (Group III), and BDM (Group IV) were compared with STH2 (Group V); postischemic recovery of aortic flow was 29+/-7%, 49+/-6%*, 56+/-2%*, 76+/-3%*, and 25+/-6%, respectively (*P<0.05 vs. I and V). Creatine kinase leakage was lowest, and myocardial ATP content was highest in Group IV. A polarizing preservation solution (KH+TTX) containing HOE694, furosemide, and BDM significantly enhanced long-term preservation compared with an optimized depolarizing solution (STH2) used clinically for long-term donor heart preservation.
Ahmad, Jumana; Swan, Garrett; Bowman, Howard; Wyble, Brad; Nobre, Anna C; Shapiro, Kimron L; McNab, Fiona
2017-07-06
Competition between simultaneously presented visual stimuli lengthens reaction time and reduces both the BOLD response and neural firing. In contrast, conditions of sequential presentation have been assumed to be free from competition. Here we manipulated the spatial proximity of stimuli (Near versus Far conditions) to examine the effects of simultaneous and sequential competition on different measures of working memory (WM) for colour. With simultaneous presentation, the measure of WM precision was significantly lower for Near items, and participants reported the colour of the wrong item more often. These effects were preserved when the second stimulus immediately followed the first, disappeared when they were separated by 500 ms, and were partly recovered (evident for our measure of mis-binding but not WM precision) when the task was altered to encourage participants to maintain the sequentially presented items together in WM. Our results show, for the first time, that competition affects the measure of WM precision, and challenge the assumption that sequential presentation removes competition.
Placebo non-response measure in sequential parallel comparison design studies.
Rybin, Denis; Doros, Gheorghe; Pencina, Michael J; Fava, Maurizio
2015-07-10
The Sequential Parallel Comparison Design (SPCD) is one of the novel approaches addressing placebo response. The analysis of SPCD data typically classifies subjects as 'placebo responders' or 'placebo non-responders'. Most current methods employed for analysis of SPCD data utilize only a part of the data collected during the trial. A repeated measures model was proposed for analysis of continuous outcomes that permitted the inclusion of information from all subjects into the treatment effect estimation. We describe here a new approach using a weighted repeated measures model that further improves the utilization of data collected during the trial, allowing the incorporation of information that is relevant to the placebo response, and dealing with the problem of possible misclassification of subjects. Our simulations show that when compared to the unweighted repeated measures model method, our approach performs as well or, under certain conditions, better, in preserving the type I error, achieving adequate power and minimizing the mean squared error. Copyright © 2015 John Wiley & Sons, Ltd.
A New Approach for Mining Order-Preserving Submatrices Based on All Common Subsequences.
Xue, Yun; Liao, Zhengling; Li, Meihang; Luo, Jie; Kuang, Qiuhua; Hu, Xiaohui; Li, Tiechen
2015-01-01
Order-preserving submatrices (OPSMs) have been applied in many fields, such as DNA microarray data analysis, automatic recommendation systems, and target marketing systems, as an important unsupervised learning model. Unfortunately, most existing methods are heuristic algorithms which are unable to reveal OPSMs entirely in NP-complete problem. In particular, deep OPSMs, corresponding to long patterns with few supporting sequences, incur explosive computational costs and are completely pruned by most popular methods. In this paper, we propose an exact method to discover all OPSMs based on frequent sequential pattern mining. First, an existing algorithm was adjusted to disclose all common subsequence (ACS) between every two row sequences, and therefore all deep OPSMs will not be missed. Then, an improved data structure for prefix tree was used to store and traverse ACS, and Apriori principle was employed to efficiently mine the frequent sequential pattern. Finally, experiments were implemented on gene and synthetic datasets. Results demonstrated the effectiveness and efficiency of this method.
Sequential limiting in continuous and discontinuous Galerkin methods for the Euler equations
NASA Astrophysics Data System (ADS)
Dobrev, V.; Kolev, Tz.; Kuzmin, D.; Rieben, R.; Tomov, V.
2018-03-01
We present a new predictor-corrector approach to enforcing local maximum principles in piecewise-linear finite element schemes for the compressible Euler equations. The new element-based limiting strategy is suitable for continuous and discontinuous Galerkin methods alike. In contrast to synchronized limiting techniques for systems of conservation laws, we constrain the density, momentum, and total energy in a sequential manner which guarantees positivity preservation for the pressure and internal energy. After the density limiting step, the total energy and momentum gradients are adjusted to incorporate the irreversible effect of density changes. Antidiffusive corrections to bounds-compatible low-order approximations are limited to satisfy inequality constraints for the specific total and kinetic energy. An accuracy-preserving smoothness indicator is introduced to gradually adjust lower bounds for the element-based correction factors. The employed smoothness criterion is based on a Hessian determinant test for the density. A numerical study is performed for test problems with smooth and discontinuous solutions.
A Node Linkage Approach for Sequential Pattern Mining
Navarro, Osvaldo; Cumplido, René; Villaseñor-Pineda, Luis; Feregrino-Uribe, Claudia; Carrasco-Ochoa, Jesús Ariel
2014-01-01
Sequential Pattern Mining is a widely addressed problem in data mining, with applications such as analyzing Web usage, examining purchase behavior, and text mining, among others. Nevertheless, with the dramatic increase in data volume, the current approaches prove inefficient when dealing with large input datasets, a large number of different symbols and low minimum supports. In this paper, we propose a new sequential pattern mining algorithm, which follows a pattern-growth scheme to discover sequential patterns. Unlike most pattern growth algorithms, our approach does not build a data structure to represent the input dataset, but instead accesses the required sequences through pseudo-projection databases, achieving better runtime and reducing memory requirements. Our algorithm traverses the search space in a depth-first fashion and only preserves in memory a pattern node linkage and the pseudo-projections required for the branch being explored at the time. Experimental results show that our new approach, the Node Linkage Depth-First Traversal algorithm (NLDFT), has better performance and scalability in comparison with state of the art algorithms. PMID:24933123
Evaluation of concurrent priority queue algorithms. Technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Q.
1991-02-01
The priority queue is a fundamental data structure that is used in a large variety of parallel algorithms, such as multiprocessor scheduling and parallel best-first search of state-space graphs. This thesis addresses the design and experimental evaluation of two novel concurrent priority queues: a parallel Fibonacci heap and a concurrent priority pool, and compares them with the concurrent binary heap. The parallel Fibonacci heap is based on the sequential Fibonacci heap, which is theoretically the most efficient data structure for sequential priority queues. This scheme not only preserves the efficient operation time bounds of its sequential counterpart, but also hasmore » very low contention by distributing locks over the entire data structure. The experimental results show its linearly scalable throughput and speedup up to as many processors as tested (currently 18). A concurrent access scheme for a doubly linked list is described as part of the implementation of the parallel Fibonacci heap. The concurrent priority pool is based on the concurrent B-tree and the concurrent pool. The concurrent priority pool has the highest throughput among the priority queues studied. Like the parallel Fibonacci heap, the concurrent priority pool scales linearly up to as many processors as tested. The priority queues are evaluated in terms of throughput and speedup. Some applications of concurrent priority queues such as the vertex cover problem and the single source shortest path problem are tested.« less
SIMPLE: a sequential immunoperoxidase labeling and erasing method.
Glass, George; Papin, Jason A; Mandell, James W
2009-10-01
The ability to simultaneously visualize expression of multiple antigens in cells and tissues can provide powerful insights into cellular and organismal biology. However, standard methods are limited to the use of just two or three simultaneous probes and have not been widely adopted for routine use in paraffin-embedded tissue. We have developed a novel approach called sequential immunoperoxidase labeling and erasing (SIMPLE) that enables the simultaneous visualization of at least five markers within a single tissue section. Utilizing the alcohol-soluble peroxidase substrate 3-amino-9-ethylcarbazole, combined with a rapid non-destructive method for antibody-antigen dissociation, we demonstrate the ability to erase the results of a single immunohistochemical stain while preserving tissue antigenicity for repeated rounds of labeling. SIMPLE is greatly facilitated by the use of a whole-slide scanner, which can capture the results of each sequential stain without any information loss.
Narrative competence in Spanish-speaking adults with Williams syndrome.
Diez-Itza, Eliseo; Martínez, Verónica; Antón, Aránzazu
2016-08-01
Williams syndrome (WS) is a genetic disorder associated with intellectual disability and characterised by displaying an atypical neuropsychological profile, with peaks and valleys, where language skills seem better preserved than non-verbal intelligence. This study researches the narrative competence of nine Spanish-speaking adults with WS. Oral narratives were elicited from a silent film, and narrative coherence was analysed as a function of sequential order of the events narrated at three structure levels, while narrative cohesion was assessed through the frequency of use and type of discourse markers. WS subjects were able to remember a significant proportion of the events from the film, but coherence of narratives, i.e., sequential order of events, was more impaired. Consistently with their linguistic abilities, cohesion of narratives was better preserved, as they used discourse markers to introduce a high proportion of events. Construction of mental models of the narratives may be constrained in WS by non-verbal cognitive abilities, but narrative competence is also determined by textual pragmatic abilities to organize discourse, which should be addressed by specific intervention in narrative competence.
Parallel seed-based approach to multiple protein structure similarities detection
Chapuis, Guillaume; Le Boudic-Jamin, Mathilde; Andonov, Rumen; ...
2015-01-01
Finding similarities between protein structures is a crucial task in molecular biology. Most of the existing tools require proteins to be aligned in order-preserving way and only find single alignments even when multiple similar regions exist. We propose a new seed-based approach that discovers multiple pairs of similar regions. Its computational complexity is polynomial and it comes with a quality guarantee—the returned alignments have both root mean squared deviations (coordinate-based as well as internal-distances based) lower than a given threshold, if such exist. We do not require the alignments to be order preserving (i.e., we consider nonsequential alignments), which makesmore » our algorithm suitable for detecting similar domains when comparing multidomain proteins as well as to detect structural repetitions within a single protein. Because the search space for nonsequential alignments is much larger than for sequential ones, the computational burden is addressed by extensive use of parallel computing techniques: a coarse-grain level parallelism making use of available CPU cores for computation and a fine-grain level parallelism exploiting bit-level concurrency as well as vector instructions.« less
Madani-Hosseini, Mahsa; Mulligan, Catherine N; Barrington, Suzelle
2016-06-01
In-Storage-Psychrophilic-Anaerobic-Digestion (ISPAD) is an ambient temperature treatment system for wastewaters stored for over 100days under temperate climates, which produces a nitrogen rich digestate susceptible to ammonia (NH3) volatilization. Present acidification techniques reducing NH3 volatilization are not only expensive and with secondary environmental effects, but do not apply to ISPAD relying on batch-to-batch inoculation. The objectives of this study were to identify and validate sequential organic loading (OL) strategies producing imbalances in acidogen and methanogen growth, acidifying ISPAD content one week before emptying to a pH of 6, while also preserving the inoculation potential. This acidification process is challenging as wastewaters often offer a high buffering capacity and ISPAD operational practices foster low microbial populations. A model simulating the ISPAD pH regime was used to optimize 3 different sequential OLs to decrease the ISPAD pH to 6.0. All 3 strategies were compared in terms of biogas production, volatile fatty acid (VFA) concentration, microbial activity, glucose consumption, and pH decrease. Laboratory validation of the model outputs confirmed that a sequential OL of 13kg glucose/m(3) of ISPAD content over 4days could indeed reduce the pH to 6.0. Such OL competes feasibly with present acidification techniques. Nevertheless, more research is required to explain the 3-day lag between the model results and the experimental data. Copyright © 2016 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Carretti, Barbara; Lanfranchi, Silvia; Mammarella, Irene C.
2013-01-01
Earlier research showed that visuospatial working memory (VSWM) is better preserved in Down syndrome (DS) than verbal WM. Some differences emerged, however, when VSWM performance was broken down into its various components, and more recent studies revealed that the spatial-simultaneous component of VSWM is more impaired than the spatial-sequential…
Doros, Gheorghe; Pencina, Michael; Rybin, Denis; Meisner, Allison; Fava, Maurizio
2013-07-20
Previous authors have proposed the sequential parallel comparison design (SPCD) to address the issue of high placebo response rate in clinical trials. The original use of SPCD focused on binary outcomes, but recent use has since been extended to continuous outcomes that arise more naturally in many fields, including psychiatry. Analytic methods proposed to date for analysis of SPCD trial continuous data included methods based on seemingly unrelated regression and ordinary least squares. Here, we propose a repeated measures linear model that uses all outcome data collected in the trial and accounts for data that are missing at random. An appropriate contrast formulated after the model has been fit can be used to test the primary hypothesis of no difference in treatment effects between study arms. Our extensive simulations show that when compared with the other methods, our approach preserves the type I error even for small sample sizes and offers adequate power and the smallest mean squared error under a wide variety of assumptions. We recommend consideration of our approach for analysis of data coming from SPCD trials. Copyright © 2013 John Wiley & Sons, Ltd.
Gomyo, Hideyuki; Ookawa, Masaki; Oshibuchi, Kota; Sugamura, Yuriko; Hosokawa, Masahito; Shionoiri, Nozomi; Maeda, Yoshiaki; Matsunaga, Tadashi; Tanaka, Tsuyoshi
2015-01-01
For high-throughput screening of novel cosmetic preservatives, a rapid and simple assay to evaluate the antimicrobial activities should be developed because the conventional agar dilution method is time-consuming and labor-intensive. To address this issue, we evaluated a microbial sensor as a tool for rapid antimicrobial activity testing. The sensor consists of an oxygen electrode and a filter membrane that holds the test microorganisms, Staphylococcus aureus and Candida albicans. The antimicrobial activity of the tested cosmetic preservative was evaluated by measuring the current increases corresponding to the decreases in oxygen consumption in the microbial respiration. The current increases detected by the sensor showed positive correlation to the concentrations of two commercially used preservatives, chlorphenesin and 2-phenoxyethanol. The same tendency was also observed when a model cosmetic product was used as a preservative solvent, indicating the feasibility in practical use. Furthermore, the microbial sensor and microfluidic flow-cell was assembled to achieve sequential measurements. The sensor system presented in this study could be useful in large-scale screening experiments.
Liu, Xing; Yu, Fen-Fen; Zhong, Yi-Min; Guo, Xin-Xing; Mao, Zhen
2015-01-01
Background: Long-term use of benzalkonium chloride (BAC)-preserved drugs is often associated with ocular surface toxicity. Ocular surface symptoms had a substantial impact on the glaucoma patients’ quality of life and compliance. This study aimed to investigate the effects of sodium hyaluronate (SH) on ocular surface toxicity induced by BAC-preserved anti-glaucoma medications treatment. Methods: Fifty-eight patients (101 eyes), who received topical BAC-preserved anti-glaucoma medications treatment and met the severe dry eye criteria, were included in the analysis. All patients were maintained the original topical anti-glaucoma treatment. In the SH-treated group (56 eyes), unpreserved 0.3% SH eye drops were administered with 3 times daily for 90 days. In the control group (55 eyes), phosphate-buffered saline were administered with 3 times daily for 90 days. Ocular Surface Disease Index (OSDI) questionnaire, break-up time (BUT) test, corneal fluorescein staining, corneal and conjunctival rose Bengal staining, Schirmer test, and conjunctiva impression cytology were performed sequentially on days 0 and 91. Results: Compared with the control group, SH-treated group showed decrease in OSDI scores (Kruskal-Wallis test: H = 38.668, P < 0.001), fluorescein and rose Bengal scores (Wilcoxon signed-ranks test: z = −3.843, P < 0.001, and z = −3.508, P < 0.001, respectively), increase in tear film BUT (t-test: t = −10.994, P < 0.001) and aqueous tear production (t-test: t = −10.328, P < 0.001) on day 91. The goblet cell density was increased (t-test: t = −9.981, P < 0.001), and the morphology of the conjunctival epithelium were also improved after SH treatment. Conclusions: SH significantly improved both symptoms and signs of ocular surface damage in patients with BAC-preserved anti-glaucoma medications treatment. SH could be proposed as a new attempt to reduce ocular surface toxicity, and alleviate symptoms of ocular surface damage in BAC-preserved anti-glaucoma medications treatment. PMID:26365960
Bang, Jihyun; Kim, Haeyoung; Kim, Hoikyung; Beuchat, Larry R; Ryu, Jee-Hoon
2011-09-01
We developed and validated a treatment to inactivate Escherichia coli O157:H7 on radish seeds without decreasing seed viability. Treatments with aqueous ClO(2) followed by drying and dry-heat treatments were evaluated for efficacy to inactivate the pathogen. Conditions to dry radish seeds after treatment with water (control) or ClO(2) were established. When treated seeds with high water activity (a(w)) (>0.99) were stored at 45°C and 23% relative humidity (RH), the a(w) decreased to <0.30 within 24 h. Drying high-a(w) seeds before exposing them to dry-heat treatment (≥60°C) was essential to preserve seed viability. The germination rate of radish seeds which had been immersed in water for 5 min, dried at 45°C and 23% RH for 24 h, and heated at 70°C for 48 h or at 80°C for 24 h was not significantly decreased (P ≤ 0.05) compared to that of untreated radish seeds. Sequential treatments with ClO(2) (500 μg/ml, 5 min), drying (45°C, 23% RH, 24 h), and dry heating (70°C, 23% RH, 48 h) eliminated E. coli O157:H7 (5.9 log CFU/g) on radish seeds and, consequently, sprouts produced from them without decreasing the germination rate. These sequential treatments are recommended for application to radish seeds intended for sprout production.
Pressman, Alice R; Avins, Andrew L; Hubbard, Alan; Satariano, William A
2011-07-01
There is a paucity of literature comparing Bayesian analytic techniques with traditional approaches for analyzing clinical trials using real trial data. We compared Bayesian and frequentist group sequential methods using data from two published clinical trials. We chose two widely accepted frequentist rules, O'Brien-Fleming and Lan-DeMets, and conjugate Bayesian priors. Using the nonparametric bootstrap, we estimated a sampling distribution of stopping times for each method. Because current practice dictates the preservation of an experiment-wise false positive rate (Type I error), we approximated these error rates for our Bayesian and frequentist analyses with the posterior probability of detecting an effect in a simulated null sample. Thus for the data-generated distribution represented by these trials, we were able to compare the relative performance of these techniques. No final outcomes differed from those of the original trials. However, the timing of trial termination differed substantially by method and varied by trial. For one trial, group sequential designs of either type dictated early stopping of the study. In the other, stopping times were dependent upon the choice of spending function and prior distribution. Results indicate that trialists ought to consider Bayesian methods in addition to traditional approaches for analysis of clinical trials. Though findings from this small sample did not demonstrate either method to consistently outperform the other, they did suggest the need to replicate these comparisons using data from varied clinical trials in order to determine the conditions under which the different methods would be most efficient. Copyright © 2011 Elsevier Inc. All rights reserved.
Pressman, Alice R.; Avins, Andrew L.; Hubbard, Alan; Satariano, William A.
2014-01-01
Background There is a paucity of literature comparing Bayesian analytic techniques with traditional approaches for analyzing clinical trials using real trial data. Methods We compared Bayesian and frequentist group sequential methods using data from two published clinical trials. We chose two widely accepted frequentist rules, O'Brien–Fleming and Lan–DeMets, and conjugate Bayesian priors. Using the nonparametric bootstrap, we estimated a sampling distribution of stopping times for each method. Because current practice dictates the preservation of an experiment-wise false positive rate (Type I error), we approximated these error rates for our Bayesian and frequentist analyses with the posterior probability of detecting an effect in a simulated null sample. Thus for the data-generated distribution represented by these trials, we were able to compare the relative performance of these techniques. Results No final outcomes differed from those of the original trials. However, the timing of trial termination differed substantially by method and varied by trial. For one trial, group sequential designs of either type dictated early stopping of the study. In the other, stopping times were dependent upon the choice of spending function and prior distribution. Conclusions Results indicate that trialists ought to consider Bayesian methods in addition to traditional approaches for analysis of clinical trials. Though findings from this small sample did not demonstrate either method to consistently outperform the other, they did suggest the need to replicate these comparisons using data from varied clinical trials in order to determine the conditions under which the different methods would be most efficient. PMID:21453792
Lang, Brian H H; Woo, Yu-Cho; Chiu, Keith Wan-Hang
2018-03-19
Assessing the efficacy and safety of sequential high-intensity focused ultrasound (HIFU) ablation in a multinodular goitre (MNG) by comparing them with single HIFU ablation. One hundred and four (84.6%) patients underwent single ablation of a single nodule (group I), while 19 (15.4%) underwent sequential ablation of two relatively-dominant nodules in a MNG (group II). Extent of shrinkage per nodule [by volume reduction ratio (VRR)], pain scores (by 0-10 visual analogue scale) during and after ablation, and rate of vocal cord palsy (VCP), skin burn and nausea/vomiting were compared between the two groups. All 19 (100%) sequential ablations completed successfully. The 3- and 6-month VRR of each nodule were comparable between the two groups (p > 0.05) and in group II, the 3- and 6-month VRR between the first and second nodules were comparable (p = 0.710 and p = 0.548, respectively). Pain score was significantly higher in group II in the morning after ablation (2.29 vs 1.15, p = 0.047) and nausea/vomiting occurred significantly more frequently in group II (15.8% vs 0.0%, p = 0.012). However, VCP and skin burn were comparable (p > 0.05). Sequential ablation had comparable efficacy and safety as single ablation. However, patients undergoing sequential ablation are at higher likelihood of pain in the following morning and nausea/vomiting after ablation. • Sequential HIFU ablation is well-tolerated in patients with two dominant thyroid nodules • More pain is experienced in the morning following sequential HIFU ablation • More nausea/vomiting is experienced following sequential HIFU ablation.
Is refreshing in working memory impaired in older age? Evidence from the retro-cue paradigm.
Loaiza, Vanessa M; Souza, Alessandra S
2018-04-10
Impairments in refreshing have been suggested as one source of working memory (WM) deficits in older age. Retro-cues provide an important method of investigating this question: a retro-cue guides attention to one WM item, thereby arguably refreshing it and increasing its accessibility compared with a no-cue baseline. In contrast to the refreshing deficit hypothesis, intact retro-cue benefits have been found in older adults. Refreshing, however, is assumed to boost not one but several WM representations when sequentially applied to them. Hence, intact refreshing requires the flexible switching of attention among WM items. So far, it remains an open question whether older adults show this flexibility. Here, we investigated whether older adults can use multiple cues to sequentially refresh WM representations. Younger and older adults completed a continuous-color delayed-estimation task, in which the number of retro-cues (0, 1, or 2) presented during the retention interval was manipulated. The results showed a similar retro-cue benefit for younger and older adults, even in the two-cue condition in which participants had to switch attention between items to refresh representations in WM. These findings suggest that the capacity to use cues to refresh information in visual WM may be preserved with age. © 2018 New York Academy of Sciences.
Camposampiero, D; Grandesso, S; Zanetti, E; Mazzucato, S; Solinas, M; Parekh, M; Frigo, A C; Gion, M; Ponzin, D
2013-01-01
Aims. To compare HB&L and BACTEC systems for detecting the microorganisms contaminating the corneal storage liquid preserved at 31°C. Methods. Human donor corneas were stored at 4°C followed by preservation at 31°C. Samples of the storage medium were inoculated in BACTEC Peds Plus/F (aerobic microorganisms), BACTEC Plus Anaerobic/F (anaerobic microorganisms), and HB&L bottles. The tests were performed (a) after six days of storage, (b) end of storage, and (c) after 24 hours of preservation in deturgescent liquid sequentially. 10,655 storage and deturgescent media samples were subjected to microbiological control using BACTEC (6-day incubation) and HB&L (24-hour incubation) systems simultaneously. BACTEC positive/negative refers to both/either aerobic and anaerobic positives/negatives, whereas HB&L can only detect the aerobic microbes, and therefore the positives/negatives depend on the presence/absence of aerobic microorganisms. Results. 147 (1.38%) samples were identified positive with at least one of the two methods. 127 samples (134 identified microorganisms) were positive with both HB&L and BACTEC. 14 HB&L+/BACTEC- and 6 BACTEC+/HB&L- were identified. Sensitivity (95.5%), specificity (99.8%), and positive (90.1%) and negative predictive values (99.9%) were high with HB&L considering a 3.5% annual contamination rate. Conclusion. HB&L is a rapid system for detecting microorganisms in corneal storage medium in addition to the existing methods.
Ray, Sumanta; Hossain, Sk Md Mosaddek; Khatun, Lutfunnesa; Mukhopadhyay, Anirban
2017-12-20
Alzheimer's disease (AD) is a chronic neuro-degenerative disruption of the brain which involves in large scale transcriptomic variation. The disease does not impact every regions of the brain at the same time, instead it progresses slowly involving somewhat sequential interaction with different regions. Analysis of the expression patterns of the genes in different regions of the brain influenced in AD surely contribute for a enhanced comprehension of AD pathogenesis and shed light on the early characterization of the disease. Here, we have proposed a framework to identify perturbation and preservation characteristics of gene expression patterns across six distinct regions of the brain ("EC", "HIP", "PC", "MTG", "SFG", and "VCX") affected in AD. Co-expression modules were discovered considering a couple of regions at once. These are then analyzed to know the preservation and perturbation characteristics. Different module preservation statistics and a rank aggregation mechanism have been adopted to detect the changes of expression patterns across brain regions. Gene ontology (GO) and pathway based analysis were also carried out to know the biological meaning of preserved and perturbed modules. In this article, we have extensively studied the preservation patterns of co-expressed modules in six distinct brain regions affected in AD. Some modules are emerged as the most preserved while some others are detected as perturbed between a pair of brain regions. Further investigation on the topological properties of preserved and non-preserved modules reveals a substantial association amongst "betweenness centrality" and "degree" of the involved genes. Our findings may render a deeper realization of the preservation characteristics of gene expression patterns in discrete brain regions affected by AD.
Cost-effectiveness of simultaneous versus sequential surgery in head and neck reconstruction.
Wong, Kevin K; Enepekides, Danny J; Higgins, Kevin M
2011-02-01
To determine whether simultaneous (ablation and reconstruction overlaps by two teams) head and neck reconstruction is cost effective compared to sequentially (ablation followed by reconstruction) performed surgery. Case-controlled study. Tertiary care hospital. Oncology patients undergoing free flap reconstruction of the head and neck. A match paired comparison study was performed with a retrospective chart review examining the total time of surgery for sequential and simultaneous surgery. Nine patients were selected for both the sequential and simultaneous groups. Sequential head and neck reconstruction patients were pair matched with patients who had undergone similar oncologic ablative or reconstructive procedures performed in a simultaneous fashion. A detailed cost analysis using the microcosting method was then undertaken looking at the direct costs of the surgeons, anesthesiologist, operating room, and nursing. On average, simultaneous surgery required 3 hours 15 minutes less operating time, leading to a cost savings of approximately $1200/case when compared to sequential surgery. This represents approximately a 15% reduction in the cost of the entire operation. Simultaneous head and neck reconstruction is more cost effective when compared to sequential surgery.
Knaak, Jan M; Spetzler, Vinzent N; Goldaracena, Nicolas; Boehnert, Markus U; Bazerbachi, Fateh; Louis, Kristine S; Adeyi, Oyedele A; Minkovich, Leonid; Yip, Paul M; Keshavjee, Shaf; Levy, Gary A; Grant, David R; Selzner, Nazia; Selzner, Markus
2014-11-01
An ischemic-type biliary stricture (ITBS) is a common feature after liver transplantation using donation after cardiac death (DCD) grafts. We compared sequential subnormothermic ex vivo liver perfusion (SNEVLP; 33°C) with cold storage (CS) for the prevention of ITBS in DCD liver grafts in pig liver transplantation (n = 5 for each group). Liver grafts were stored for 10 hours at 4°C (CS) or preserved with combined 7-hour CS and 3-hour SNEVLP. Parameters of hepatocyte [aspartate aminotransferase (AST), international normalized ratio (INR), factor V, and caspase 3 immunohistochemistry], endothelial cell (EC; CD31 immunohistochemistry and hyaluronic acid), and biliary injury and function [alkaline phosphatase (ALP), total bilirubin, and bile lactate dehydrogenase (LDH)] were determined. Long-term survival (7 days) after transplantation was similar between the SNEVLP and CS groups (60% versus 40%, P = 0.13). No difference was observed between SNEVLP- and CS-treated animals with respect to the peak of serum INR, factor V, or AST levels within 24 hours. CD31 staining 8 hours after transplantation demonstrated intact EC lining in SNEVLP-treated livers (7.3 × 10(-4) ± 2.6 × 10(-4) cells/μm(2)) but not in CS-treated livers (3.7 × 10(-4) ± 1.3 × 10(-4) cells/μm(2) , P = 0.03). Posttransplant SNEVLP animals had decreased serum ALP and serum bilirubin levels in comparison with CS animals. In addition, LDH in bile fluid was lower in SNEVLP pigs versus CS pigs (14 ± 10 versus 60 ± 18 μmol/L, P = 0.02). Bile duct histology revealed severe bile duct necrosis in 3 of 5 animals in the CS group but none in the SNEVLP group (P = 0.03). Sequential SNEVLP preservation of DCD grafts reduces bile duct and EC injury after liver transplantation. © 2014 American Association for the Study of Liver Diseases.
MAI, HAI-XING; LIU, JUN-LE; PEI, SHU-JUN; ZHAO, LI; QU, NAN; DONG, JIN-KAI; CHEN, BIAO; WANG, YA-LIN; HUANG, CHENG; CHEN, LI-JUN
2015-01-01
This study aimed to assess the short-term efficacy of sequential therapy for T2/T3a bladder cancer with intravesical single-port laparoscopic partial cystectomy or open partial cystectomy combined with cisplatin plus gemcitabine (GC) chemotherapy in a prospective randomized controlled study. Thirty patients with bladder cancer who underwent open partial cystectomy (group A) or single-port laparoscopic partial cystectomy (group B) and received standard GC chemotherapy were analyzed. Perioperative functional indicators and tumor recurrence during a 1-year postoperative follow-up were compared between the two groups. The baseline characteristics were comparable between the two groups. The mean operative time, amount of blood loss and duration of hospital stay were 90.3 min, 182.0 ml and 7.3 days, respectively, for group A, and 105.3 min, 49.3 ml and 5.8 days, respectively, for group B. No secondary postoperative bleeding, urine leakage, wound infection or other complications were observed in the two groups. Postoperative scarring was not evident in group B. The overall incidence of surgical complications, tumor recurrence rate and complications during chemotherapy in the postoperative follow-up period of 12 months were similar between the two groups. Single-port laparoscopic partial cystectomy surgery is an idea surgical method for the treatment of invasive bladder cancer, with good surgical effect, minimal invasiveness, rapid recovery and short hospital stay. The data from 1-year postoperative follow-up showed that laparoscopic surgery was superior with regard to perioperative bleeding, postoperative recovery and duration of indwelling urinary catheter use. However, regarding the tumor recurrence rate, long-term comparative details are required to determine the effect of laparoscopic surgery. PMID:26170915
Microcomputer Software Engineering, Documentation and Evaluation
1981-03-31
local dealer or call for complete specificalons. eAUTOMATIC INC To proceed step by step, we need toUe G T A TOMA IC NC. know where we are going and a...MICROPROCESSOR normal sequence that should be DIRECT MEMORY ACCESS preserved in the documentation. For INTRODUCTION 2.2 DRIVE CONTROLS example, you...with linear, sequential logic (like a computer). It is also the verbal side and controls language. The right side specializes in images, music, pictures
van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H
2013-11-01
There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (<50 or ≥60 years) and BP (<140/90 mm Hg or ≥140/90 mm Hg). Three simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (P<.01). However, the first sequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, P<.01 for both). Within-visit reproducibility was identical (both r=0.60). Simultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.
Manheimer, Eric D.; Peters, M. Robert; Wolff, Steven D.; Qureshi, Mehreen A.; Atluri, Prashanth; Pearson, Gregory D.N.; Einstein, Andrew J.
2011-01-01
Triple-rule-out computed tomography angiography (TRO CTA), performed to evaluate the coronary arteries, pulmonary arteries, and thoracic aorta, has been associated with high radiation exposure. Utilization of sequential scanning for coronary computed tomography angiography (CCTA) reduces radiation dose. The application of sequential scanning to TRO CTA is much less well defined. We analyzed radiation dose and image quality from TRO CTA performed in a single outpatient center, comparing scans from a period during which helical scanning with electrocardiographically controlled tube current modulation was used for all patients (n=35) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n=35). Sequential scanning was able to be employed in 86% of cases. The sequential-if-appropriate strategy, compared to the helical-only strategy, was associated with a 61.6% dose decrease (mean dose-length product [DLP] of 439 mGy×cm vs 1144 mGy×cm and mean effective dose of 7.5 mSv vs 19.4 mSv, respectively, p<0.0001). Similarly, there was a 71.5% dose reduction among 30 patients scanned with the sequential protocol compared to 40 patients scanned with the helical protocol under either strategy (326 mGy×cm vs 1141 mGy×cm and 5.5 mSv vs 19.4 mSv, respectively, p<0.0001). Although image quality did not differ between strategies, there was a non-statistically significant trend towards better quality in the sequential protocol compared to the helical protocol. In conclusion, approaching TRO CTA with a diagnostic strategy of sequential scanning as appropriate offers a marked reduction in radiation dose while maintaining image quality. PMID:21306693
2017-01-01
Objective Anticipation of opponent actions, through the use of advanced (i.e., pre-event) kinematic information, can be trained using video-based temporal occlusion. Typically, this involves isolated opponent skills/shots presented as trials in a random order. However, two different areas of research concerning representative task design and contextual (non-kinematic) information, suggest this structure of practice restricts expert performance. The aim of this study was to examine the effect of a sequential structure of practice during video-based training of anticipatory behavior in tennis, as well as the transfer of these skills to the performance environment. Methods In a pre-practice-retention-transfer design, participants viewed life-sized video of tennis rallies across practice in either a sequential order (sequential group), in which participants were exposed to opponent skills/shots in the order they occur in the sport, or a non-sequential (non-sequential group) random order. Results In the video-based retention test, the sequential group was significantly more accurate in their anticipatory judgments when the retention condition replicated the sequential structure compared to the non-sequential group. In the non-sequential retention condition, the non-sequential group was more accurate than the sequential group. In the field-based transfer test, overall decision time was significantly faster in the sequential group compared to the non-sequential group. Conclusion Findings highlight the benefits of a sequential structure of practice for the transfer of anticipatory behavior in tennis. We discuss the role of contextual information, and the importance of representative task design, for the testing and training of perceptual-cognitive skills in sport. PMID:28355263
Induction of simultaneous and sequential malolactic fermentation in durian wine.
Taniasuri, Fransisca; Lee, Pin-Rou; Liu, Shao-Quan
2016-08-02
This study represented for the first time the impact of malolactic fermentation (MLF) induced by Oenococcus oeni and its inoculation strategies (simultaneous vs. sequential) on the fermentation performance as well as aroma compound profile of durian wine. There was no negative impact of simultaneous inoculation of O. oeni and Saccharomyces cerevisiae on the growth and fermentation kinetics of S. cerevisiae as compared to sequential fermentation. Simultaneous MLF did not lead to an excessive increase in volatile acidity as compared to sequential MLF. The kinetic changes of organic acids (i.e. malic, lactic, succinic, acetic and α-ketoglutaric acids) varied with simultaneous and sequential MLF relative to yeast alone. MLF, regardless of inoculation mode, resulted in higher production of fermentation-derived volatiles as compared to control (alcoholic fermentation only), including esters, volatile fatty acids, and terpenes, except for higher alcohols. Most indigenous volatile sulphur compounds in durian were decreased to trace levels with little differences among the control, simultaneous and sequential MLF. Among the different wines, the wine with simultaneous MLF had higher concentrations of terpenes and acetate esters while sequential MLF had increased concentrations of medium- and long-chain ethyl esters. Relative to alcoholic fermentation only, both simultaneous and sequential MLF reduced acetaldehyde substantially with sequential MLF being more effective. These findings illustrate that MLF is an effective and novel way of modulating the volatile and aroma compound profile of durian wine. Copyright © 2016 Elsevier B.V. All rights reserved.
Comparison of Filters Dedicated to Speckle Suppression in SAR Images
NASA Astrophysics Data System (ADS)
Kupidura, P.
2016-06-01
This paper presents the results of research on the effectiveness of different filtering methods dedicated to speckle suppression in SAR images. The tests were performed on RadarSat-2 images and on an artificial image treated with simulated speckle noise. The research analysed the performance of particular filters related to the effectiveness of speckle suppression and to the ability to preserve image details and edges. Speckle is a phenomenon inherent to radar images - a deterministic noise connected with land cover type, but also causing significant changes in digital numbers of pixels. As a result, it may affect interpretation, classification and other processes concerning radar images. Speckle, resembling "salt and pepper" noise, has the form of a set of relatively small groups of pixels of values markedly different from values of other pixels representing the same type of land cover. Suppression of this noise may also cause suppression of small image details, therefore the ability to preserve the important parts of an image, was analysed as well. In the present study, selected filters were tested, and methods dedicated particularly to speckle noise suppression: Frost, Gamma-MAP, Lee, Lee-Sigma, Local Region, general filtering methods which might be effective in this respect: Mean, Median, in addition to morphological filters (alternate sequential filters with multiple structuring element and by reconstruction). The analysis presented in this paper compared the effectiveness of different filtering methods. It proved that some of the dedicated radar filters are efficient tools for speckle suppression, but also demonstrated a significant efficiency of the morphological approach, especially its ability to preserve image details.
High-mobility capacitively-induced two-dimensional electrons in a lateral superlattice potential
Lu, Tzu -Ming; Laroche, Dominique; Huang, S. -H.; ...
2016-01-01
In the presence of a lateral periodic potential modulation, two-dimensional electrons may exhibit interesting phenomena, such as a graphene-like energy-momentum dispersion, Bloch oscillations, or the Hofstadter butterfly band structure. To create a sufficiently strong potential modulation using conventional semiconductor heterostructures, aggressive device processing is often required, unfortunately resulting in strong disorder that masks the sought-after effects. Here, we report a novel fabrication process flow for imposing a strong lateral potential modulation onto a capacitively induced two-dimensional electron system, while preserving the host material quality. Using this process flow, the electron density in a patterned Si/SiGe heterostructure can be tuned overmore » a wide range, from 4.4 × 10 10 cm –2 to 1.8 × 10 11 cm –2, with a peak mobility of 6.4 × 10 5 cm 2/V·s. The wide density tunability and high electron mobility allow us to observe sequential emergence of commensurability oscillations as the density, the mobility, and in turn the mean free path, increase. Magnetic-field-periodic quantum oscillations associated with various closed orbits also emerge sequentially with increasing density. We show that, from the density dependence of the quantum oscillations, one can directly extract the steepness of the imposed superlattice potential. Lastly, this result is then compared to a conventional lateral superlattice model potential.« less
Naik, Umesh Chandra; Das, Mihir Tanay; Sauran, Swati; Thakur, Indu Shekhar
2014-03-01
The present study compares in vitro toxicity of electroplating effluent after the batch treatment process with that obtained after the sequential treatment process. Activated charcoal prepared from sugarcane bagasse through chemical carbonization, and tolerant indigenous bacteria, Bacillus sp. strain IST105, were used individually and sequentially for the treatment of electroplating effluent. The sequential treatment involving activated charcoal followed by bacterial treatment removed 99% of Cr(VI) compared with the batch processes, which removed 40% (charcoal) and 75% (bacteria), respectively. Post-treatment in vitro cyto/genotoxicity was evaluated by the MTT test and the comet assay in human HuH-7 hepatocarcinoma cells. The sequentially treated sample showed an increase in LC50 value with a 6-fold decrease in comet-assay DNA migration compared with that of untreated samples. A significant decrease in DNA migration and an increase in LC50 value of treated effluent proved the higher effectiveness of the sequential treatment process over the individual batch processes. Copyright © 2014 Elsevier B.V. All rights reserved.
Comparison of ablation centration after bilateral sequential versus simultaneous LASIK.
Lin, Jane-Ming; Tsai, Yi-Yu
2005-01-01
To compare ablation centration after bilateral sequential and simultaneous myopic LASIK. A retrospective randomized case series was performed of 670 eyes of 335 consecutive patients who had undergone either bilateral sequential (group 1) or simultaneous (group 2) myopic LASIK between July 2000 and July 2001 at the China Medical University Hospital, Taichung, Taiwan. The ablation centrations of the first and second eyes in the two groups were compared 3 months postoperatively. Of 670 eyes, 274 eyes (137 patients) comprised the sequential group and 396 eyes (198 patients) comprised the simultaneous group. Three months post-operatively, 220 eyes of 110 patients (80%) in the sequential group and 236 eyes of 118 patients (60%) in the simultaneous group provided topographic data for centration analysis. For the first eyes, mean decentration was 0.39 +/- 0.26 mm in the sequential group and 0.41 +/- 0.19 mm in the simultaneous group (P = .30). For the second eyes, mean decentration was 0.28 +/- 0.23 mm in the sequential group and 0.30 +/- 0.21 mm in the simultaneous group (P = .36). Decentration in the second eyes significantly improved in both groups (group 1, P = .02; group 2, P < .01). The mean distance between the first and second eyes was 0.31 +/- 0.25 mm in the sequential group and 0.32 +/- 0.18 mm in the simultaneous group (P = .33). The difference of ablation center angles between the first and second eyes was 43.2 < or = 48.3 degrees in the sequential group and 45.1 +/- 50.8 degrees in the simultaneous group (P = .42). Simultaneous bilateral LASIK is comparable to sequential surgery in ablation centration.
Sequential generations of honey bee (Apis mellifera) queens produced using cryopreserved semen.
Hopkins, Brandon K; Herr, Charles; Sheppard, Walter S
2012-01-01
Much of the world's food production is dependent on honey bees for pollination, and expanding food production will further increase the demand for managed pollination services. Apiculturists outside the native range of the honey bee, in the Americas, Australia and eastern Asia, have used only a few of the 27 described subspecies of honey bees (Apis mellifera) for beekeeping purposes. Within the endemic ranges of a particular subspecies, hybridisation can threaten native subspecies when local beekeepers import and propagate non-native honey bees. For many threatened species, cryopreserved germplasm can provide a resource for the preservation of diversity and recovery of endangered populations. However, although instrumental insemination of queen honey bees is well established, the absence of an effective means to cryopreserve honey bee semen has limited the success of efforts to preserve genetic diversity within the species or to develop repositories of honey bee germplasm for breeding purposes. Herein we report that some queens inseminated with cryopreserved semen were capable of producing a substantial number of fertilised offspring. These diploid female larvae were used to produce two additional sequential generations of new queens, which were then back-crossed to the same stock of frozen semen. Our results demonstrate the ability to produce queens using cryopreserved honey bee spermatozoa and the potential for the establishment of a honey bee genetic repository.
Sukumaran, Lakshmi; McCarthy, Natalie L; Kharbanda, Elyse O; Weintraub, Eric S; Vazquez-Benitez, Gabriela; McNeil, Michael M; Li, Rongxia; Klein, Nicola P; Hambidge, Simon J; Naleway, Allison L; Lugg, Marlene M; Jackson, Michael L; King, Jennifer P; DeStefano, Frank; Omer, Saad B; Orenstein, Walter A
2015-11-01
To evaluate the safety of coadministering tetanus toxoid, reduced diphtheria toxoid, and acellular pertussis (Tdap) and influenza vaccines during pregnancy by comparing adverse events after concomitant and sequential vaccination. We conducted a retrospective cohort study of pregnant women aged 14-49 years in the Vaccine Safety Datalink from January 1, 2007, to November 15, 2013. We compared medically attended acute events (fever, any acute reaction) and adverse birth outcomes (preterm delivery, low birth weight, small for gestational age) in women receiving concomitant Tdap and influenza vaccination and women receiving sequential vaccination. Among 36,844 pregnancies in which Tdap and influenza vaccines were administered, the vaccines were administered concomitantly in 8,464 (23%) pregnancies and sequentially in 28,380 (77%) pregnancies. Acute adverse events after vaccination were rare. We found no statistically significant increased risk of fever or any medically attended acute adverse event in pregnant women vaccinated concomitantly compared with sequentially. When analyzing women at 20 weeks of gestation or greater during periods of influenza vaccine administration, there were no differences in preterm delivery, low-birth-weight, or small-for-gestational-age neonates between women vaccinated concomitantly compared with sequentially in pregnancy. Concomitant administration of Tdap and influenza vaccines during pregnancy was not associated with a higher risk of medically attended adverse acute outcomes or birth outcomes compared with sequential vaccination. II.
A Bayesian sequential design using alpha spending function to control type I error.
Zhu, Han; Yu, Qingzhao
2017-10-01
We propose in this article a Bayesian sequential design using alpha spending functions to control the overall type I error in phase III clinical trials. We provide algorithms to calculate critical values, power, and sample sizes for the proposed design. Sensitivity analysis is implemented to check the effects from different prior distributions, and conservative priors are recommended. We compare the power and actual sample sizes of the proposed Bayesian sequential design with different alpha spending functions through simulations. We also compare the power of the proposed method with frequentist sequential design using the same alpha spending function. Simulations show that, at the same sample size, the proposed method provides larger power than the corresponding frequentist sequential design. It also has larger power than traditional Bayesian sequential design which sets equal critical values for all interim analyses. When compared with other alpha spending functions, O'Brien-Fleming alpha spending function has the largest power and is the most conservative in terms that at the same sample size, the null hypothesis is the least likely to be rejected at early stage of clinical trials. And finally, we show that adding a step of stop for futility in the Bayesian sequential design can reduce the overall type I error and reduce the actual sample sizes.
Van Parijs, Hilde; Reynders, Truus; Heuninckx, Karina; Verellen, Dirk; Storme, Guy; De Ridder, Mark
2014-01-01
Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001). There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04). The dose to the organs at risk (OAR) was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine.
Reynders, Truus; Heuninckx, Karina; Verellen, Dirk; Storme, Guy; De Ridder, Mark
2014-01-01
Background. Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. Methods. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. Results. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001). There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04). The dose to the organs at risk (OAR) was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. Conclusions. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine. PMID:25162031
Scholes, D Tyler; Hawks, Steven A; Yee, Patrick Y; Wu, Hao; Lindemuth, Jeffrey R; Tolbert, Sarah H; Schwartz, Benjamin J
2015-12-03
We demonstrate that solution-sequential processing (SqP) can yield heavily doped pristine-quality films when used to infiltrate the molecular dopant 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ) into pure poly(3-hexylthiophene) (P3HT) polymer layers. Profilometry measurements show that the SqP method produces doped films with essentially the same surface roughness as pristine films, and 2-D grazing-incidence wide-angle X-ray scattering (GIWAXS) confirms that SqP preserves both the size and orientation of the pristine polymer's crystallites. Unlike traditional blend-cast F4TCNQ/P3HT doped films, our sequentially processed layers have tunable and reproducible conductivities reaching as high as 5.5 S/cm even when measured over macroscopic (>1 cm) distances. The high conductivity and superb film quality allow for meaningful Hall effect measurements, which reveal p-type conduction and carrier concentrations tunable from 10(16) to 10(20) cm(-3) and hole mobilities ranging from ∼0.003 to 0.02 cm(2) V(-1) s(-1) at room temperature over the doping levels examined.
Palmer, Matthew A; Brewer, Neil
2012-06-01
When compared with simultaneous lineup presentation, sequential presentation has been shown to reduce false identifications to a greater extent than it reduces correct identifications. However, there has been much debate about whether this difference in identification performance represents improved discriminability or more conservative responding. In this research, data from 22 experiments that compared sequential and simultaneous lineups were analyzed using a compound signal-detection model, which is specifically designed to describe decision-making performance on tasks such as eyewitness identification tests. Sequential (cf. simultaneous) presentation did not influence discriminability, but produced a conservative shift in response bias that resulted in less-biased choosing for sequential than simultaneous lineups. These results inform understanding of the effects of lineup presentation mode on eyewitness identification decisions.
Effects of neostriatal 6-OHDA lesion on performance in a rat sequential reaction time task.
Domenger, D; Schwarting, R K W
2008-10-31
Work in humans and monkeys has provided evidence that the basal ganglia, and the neurotransmitter dopamine therein, play an important role for sequential learning and performance. Compared to primates, experimental work in rodents is rather sparse, largely due to the fact that tasks comparable to the human ones, especially serial reaction time tasks (SRTT), had been lacking until recently. We have developed a rat model of the SRTT, which allows to study neural correlates of sequential performance and motor sequence execution. Here, we report the effects of dopaminergic neostriatal lesions, performed using bilateral 6-hydroxydopamine injections, on performance of well-trained rats tested in our SRTT. Sequential behavior was measured in two ways: for one, the effects of small violations of otherwise well trained sequences were examined as a measure of attention and automation. Secondly, sequential versus random performance was compared as a measure of sequential learning. Neurochemically, the lesions led to sub-total dopamine depletions in the neostriatum, which ranged around 60% in the lateral, and around 40% in the medial neostriatum. These lesions led to a general instrumental impairment in terms of reduced speed (response latencies) and response rate, and these deficits were correlated with the degree of striatal dopamine loss. Furthermore, the violation test indicated that the lesion group conducted less automated responses. The comparison of random versus sequential responding showed that the lesion group did not retain its superior sequential performance in terms of speed, whereas they did in terms of accuracy. Also, rats with lesions did not improve further in overall performance as compared to pre-lesion values, whereas controls did. These results support previous results that neostriatal dopamine is involved in instrumental behaviour in general. Also, these lesions are not sufficient to completely abolish sequential performance, at least when acquired before lesion as tested here.
Sequentially reweighted TV minimization for CT metal artifact reduction.
Zhang, Xiaomeng; Xing, Lei
2013-07-01
Metal artifact reduction has long been an important topic in x-ray CT image reconstruction. In this work, the authors propose an iterative method that sequentially minimizes a reweighted total variation (TV) of the image and produces substantially artifact-reduced reconstructions. A sequentially reweighted TV minimization algorithm is proposed to fully exploit the sparseness of image gradients (IG). The authors first formulate a constrained optimization model that minimizes a weighted TV of the image, subject to the constraint that the estimated projection data are within a specified tolerance of the available projection measurements, with image non-negativity enforced. The authors then solve a sequence of weighted TV minimization problems where weights used for the next iteration are computed from the current solution. Using the complete projection data, the algorithm first reconstructs an image from which a binary metal image can be extracted. Forward projection of the binary image identifies metal traces in the projection space. The metal-free background image is then reconstructed from the metal-trace-excluded projection data by employing a different set of weights. Each minimization problem is solved using a gradient method that alternates projection-onto-convex-sets and steepest descent. A series of simulation and experimental studies are performed to evaluate the proposed approach. Our study shows that the sequentially reweighted scheme, by altering a single parameter in the weighting function, flexibly controls the sparsity of the IG and reconstructs artifacts-free images in a two-stage process. It successfully produces images with significantly reduced streak artifacts, suppressed noise and well-preserved contrast and edge properties. The sequentially reweighed TV minimization provides a systematic approach for suppressing CT metal artifacts. The technique can also be generalized to other "missing data" problems in CT image reconstruction.
Xu, Guangyang; Zhu, Chenghao; Gu, Weijin; Li, Jian; Sun, Jiangtao
2015-01-12
An unprecedented gold-catalyzed ligand-controlled cross-coupling of diazo compounds by sequential selective denitrogenation and cyclization affords N-substituted pyrazoles in a position-switchable mode. This novel transformation features selective decomposition of one diazo moiety and simultaneous preservation of the other one from two substrates. Notably, the choice of the ancillary ligand to the gold complex plays a pivotal role on the chemo- and regioselectivity of the reactions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Einstein, Andrew J.; Wolff, Steven D.; Manheimer, Eric D.; Thompson, James; Terry, Sylvia; Uretsky, Seth; Pilip, Adalbert; Peters, M. Robert
2009-01-01
Radiation dose from coronary computed tomography angiography may be reduced using a sequential scanning protocol rather than a conventional helical scanning protocol. Here we compare radiation dose and image quality from coronary computed tomography angiography in a single center between an initial period during which helical scanning with electrocardiographically-controlled tube current modulation was used for all patients (n=138) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n=261). Using the sequential-if-appropriate strategy, sequential scanning was employed in 86.2% of patients. Compared to the helical-only strategy, this strategy was associated with a 65.1% dose reduction (mean dose-length product of 305.2 vs. 875.1 and mean effective dose of 14.9 mSv vs. 5.2 mSv, respectively), with no significant change in overall image quality, step artifacts, motion artifacts, or perceived image noise. For the 225 patients undergoing sequential scanning, the dose-length product was 201.9 ± 90.0 mGy·cm, while for patients undergoing helical scanning under either strategy, the dose-length product was 890.9 ± 293.3 mGy·cm (p<0.0001), corresponding to mean effective doses of 3.4 mSv and 15.1 mSv, respectively, a 77.5% reduction. Image quality was significantly greater for the sequential studies, reflecting the poorer image quality in patients undergoing helical scanning in the sequential-if-appropriate strategy. In conclusion, a sequential-if-appropriate diagnostic strategy reduces dose markedly compared to a helical-only strategy, with no significant difference in image quality. PMID:19892048
Sequential causal inference: Application to randomized trials of adaptive treatment strategies
Dawson, Ree; Lavori, Philip W.
2009-01-01
SUMMARY Clinical trials that randomize subjects to decision algorithms, which adapt treatments over time according to individual response, have gained considerable interest as investigators seek designs that directly inform clinical decision making. We consider designs in which subjects are randomized sequentially at decision points, among adaptive treatment options under evaluation. We present a sequential method to estimate the comparative effects of the randomized adaptive treatments, which are formalized as adaptive treatment strategies. Our causal estimators are derived using Bayesian predictive inference. We use analytical and empirical calculations to compare the predictive estimators to (i) the ‘standard’ approach that allocates the sequentially obtained data to separate strategy-specific groups as would arise from randomizing subjects at baseline; (ii) the semi-parametric approach of marginal mean models that, under appropriate experimental conditions, provides the same sequential estimator of causal differences as the proposed approach. Simulation studies demonstrate that sequential causal inference offers substantial efficiency gains over the standard approach to comparing treatments, because the predictive estimators can take advantage of the monotone structure of shared data among adaptive strategies. We further demonstrate that the semi-parametric asymptotic variances, which are marginal ‘one-step’ estimators, may exhibit significant bias, in contrast to the predictive variances. We show that the conditions under which the sequential method is attractive relative to the other two approaches are those most likely to occur in real studies. PMID:17914714
Wendt, D; Schmidt, D; Wasserfuhr, D; Osswald, B; Thielmann, M; Tossios, P; Kühl, H; Jakob, H; Massoudy, P
2010-09-01
The superiority of left internal thoracic artery (LITA) grafting to the left anterior descending artery (LAD) is well established. Patency rates of 80%-90% have been reported at 10-year follow-up. However, the superiority of sequential LITA grafting has not been proven. Our aim was to compare patency rates after sequential LITA grafting to a diagonal branch and the LAD with patency rates of LITA grafting to the LAD and separate vein grafting to a diagonal branch. A total of 58 coronary artery bypass graft (CABG) patients, operated on between 01/2000 and 12/2002, underwent multi-slice computed tomography (MSCT) between 2006 and 2008. Of these patients, 29 had undergone sequential LITA grafting to a diagonal branch and to the LAD ("Sequential" Group), while in 29 the LAD and a diagonal branch were separately grafted with LITA and vein ("Separate" Group). Patencies of all anastomoses were investigated. Mean follow-up was 1958±208 days. The patency rate of the LAD anastomosis was 100% in the Sequential Group and 93% in the Separate Group (p=0.04). The patency rate of the diagonal branch anastomosis was 100% in the Sequential Group and 89% in the Separate Group (p=0.04). Mean intraoperative flow on LITA graft was not different between groups (69±8ml/min in the Sequential Group and 68±9ml/min in the Separate Group, p=n.s.). Patency rates of both the LAD and the diagonal branch anastomoses were higher after sequential arterial grafting compared with separate arterial and venous grafting at 5-year follow-up. This indicates that, with regard to the antero-lateral wall of the left ventricle, there is an advantage to sequential arterial grafting compared with separate arterial and venous grafting.
Neel, Sean T
2014-11-01
A cost analysis was performed to evaluate the effect on physicians in the United States of a transition from delayed sequential cataract surgery to immediate sequential cataract surgery. Financial and efficiency impacts of this change were evaluated to determine whether efficiency gains could offset potential reduced revenue. A cost analysis using Medicare cataract surgery volume estimates, Medicare 2012 physician cataract surgery reimbursement schedules, and estimates of potential additional office visit revenue comparing immediate sequential cataract surgery with delayed sequential cataract surgery for a single specialty ophthalmology practice in West Tennessee. This model should give an indication of the effect on physicians on a national basis. A single specialty ophthalmology practice in West Tennessee was found to have a cataract surgery revenue loss of $126,000, increased revenue from office visits of $34,449 to $106,271 (minimum and maximum offset methods), and a net loss of $19,900 to $91,700 (base case) with the conversion to immediate sequential cataract surgery. Physicians likely stand to lose financially, and this loss cannot be offset by increased patient visits under the current reimbursement system. This may result in physician resistance to converting to immediate sequential cataract surgery, gaming, and supplier-induced demand.
James, Erica; Freund, Megan; Booth, Angela; Duncan, Mitch J; Johnson, Natalie; Short, Camille E; Wolfenden, Luke; Stacey, Fiona G; Kay-Lambkin, Frances; Vandelanotte, Corneel
2016-08-01
Growing evidence points to the benefits of addressing multiple health behaviors rather than single behaviors. This review evaluates the relative effectiveness of simultaneous and sequentially delivered multiple health behavior change (MHBC) interventions. Secondary aims were to identify: a) the most effective spacing of sequentially delivered components; b) differences in efficacy of MHBC interventions for adoption/cessation behaviors and lifestyle/addictive behaviors, and; c) differences in trial retention between simultaneously and sequentially delivered interventions. MHBC intervention trials published up to October 2015 were identified through a systematic search. Eligible trials were randomised controlled trials that directly compared simultaneous and sequential delivery of a MHBC intervention. A narrative synthesis was undertaken. Six trials met the inclusion criteria and across these trials the behaviors targeted were smoking, diet, physical activity, and alcohol consumption. Three trials reported a difference in intervention effect between a sequential and simultaneous approach in at least one behavioral outcome. Of these, two trials favoured a sequential approach on smoking. One trial favoured a simultaneous approach on fat intake. There was no difference in retention between sequential and simultaneous approaches. There is limited evidence regarding the relative effectiveness of sequential and simultaneous approaches. Given only three of the six trials observed a difference in intervention effectiveness for one health behavior outcome, and the relatively consistent finding that the sequential and simultaneous approaches were more effective than a usual/minimal care control condition, it appears that both approaches should be considered equally efficacious. PROSPERO registration number: CRD42015027876. Copyright © 2016 Elsevier Inc. All rights reserved.
Lau, Christine S M; Ward, Amanda; Chamberlain, Ronald S
2016-06-01
Helicobacter pylori is a common infection associated with many gastrointestinal diseases. Triple or quadruple therapy is the current recommendation for H pylori eradication in children but is associated with success rates as low as 50%. Recent studies have demonstrated that a 10-day sequential therapy regimen, rather than simultaneous antibiotic administration, achieved eradication rates of nearly 95%. This meta-analysis found that sequential therapy increased eradication rates by 14.2% (relative risk [RR] = 1.142; 95% confidence interval [CI] = 1.082-1.207; P < .001). Ten-day sequential therapy significantly improved H pylori eradication rates compared to the 7-day standard therapy (RR = 1.182; 95% CI = 1.102-1.269; p < .001) and 10-day standard therapy (RR = 1.179; 95% CI = 1.074-1.295; P = .001), but had lower eradication rates compared to 14-day standard therapy (RR = 0.926; 95% CI = 0.811-1.059; P = .261). The use of sequential therapy is associated with increased H pylori eradication rates in children compared to standard therapy of equal or shorter duration. © The Author(s) 2015.
Trott, C M; Ouyang, J; El Fakhri, G
2010-11-21
Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest (99m)Tc-sestamibi/(123)I-BMIPP imaging protocol in place of the commonly used sequential rest/stress (99m)Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.
Cost-Utility Analysis of Cochlear Implantation in Australian Adults.
Foteff, Chris; Kennedy, Steven; Milton, Abul Hasnat; Deger, Melike; Payk, Florian; Sanderson, Georgina
2016-06-01
Sequential and simultaneous bilateral cochlear implants are emerging as appropriate treatment options for Australian adults with sensory deficits in both cochleae. Current funding of Australian public hospitals does not provide for simultaneous bilateral cochlear implantation (CI) as a separate surgical procedure. Previous cost-effectiveness studies of sequential and simultaneous bilateral CI assumed 100% of unilaterally treated patients' transition to a sequential bilateral CI. This assumption does not place cochlear implantation in the context of the generally treated population. When mutually exclusive treatment options exist, such as unilateral CI, sequential bilateral CI, and simultaneous bilateral CI, the mean costs of the treated populations are weighted in the calculation of incremental cost-utility ratios. The objective was to evaluate the cost-utility of bilateral hearing aids (HAs) compared with unilateral, sequential, and simultaneous bilateral CI in Australian adults with bilateral severe to profound sensorineural hearing loss. Cost-utility analysis of secondary sources input to a Markov model. Australian health care perspective, lifetime horizon with costs and outcomes discounted 5% annually. Bilateral HAs as treatment for bilateral severe to profound sensorineural hearing loss compared with unilateral, sequential, and simultaneous bilateral CI. Incremental costs per quality adjusted life year (AUD/QALY). When compared with bilateral hearing aids the incremental cost-utility ratio for the CI treatment population was AUD11,160/QALY. The incremental cost-utility ratio was weighted according to the number of patients treated unilaterally, sequentially, and simultaneously, as these were mutually exclusive treatment options. No peer-reviewed articles have reported the incremental analysis of cochlear implantation in a continuum of care for surgically treated populations with bilateral severe to profound sensorineural hearing loss. Unilateral, sequential, and simultaneous bilateral CI were cost-effective when compared with bilateral hearing aids. Technologies that reduce the total number of visits for a patient could introduce additional cost efficiencies into clinical practice.
Harari, Colin M; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T; Lubner, Meghan G; Hinshaw, J Louis; Ziemlewicz, Timothy; Brace, Christopher L
2016-01-01
To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015.
Configural and component processing in simultaneous and sequential lineup procedures.
Flowe, Heather D; Smith, Harriet M J; Karoğlu, Nilda; Onwuegbusi, Tochukwu O; Rai, Lovedeep
2016-01-01
Configural processing supports accurate face recognition, yet it has never been examined within the context of criminal identification lineups. We tested, using the inversion paradigm, the role of configural processing in lineups. Recent research has found that face discrimination accuracy in lineups is better in a simultaneous compared to a sequential lineup procedure. Therefore, we compared configural processing in simultaneous and sequential lineups to examine whether there are differences. We had participants view a crime video, and then they attempted to identify the perpetrator from a simultaneous or sequential lineup. The test faces were presented either upright or inverted, as previous research has shown that inverting test faces disrupts configural processing. The size of the inversion effect for faces was the same across lineup procedures, indicating that configural processing underlies face recognition in both procedures. Discrimination accuracy was comparable across lineup procedures in both the upright and inversion condition. Theoretical implications of the results are discussed.
Orphan therapies: making best use of postmarket data.
Maro, Judith C; Brown, Jeffrey S; Dal Pan, Gerald J; Li, Lingling
2014-08-01
Postmarket surveillance of the comparative safety and efficacy of orphan therapeutics is challenging, particularly when multiple therapeutics are licensed for the same orphan indication. To make best use of product-specific registry data collected to fulfill regulatory requirements, we propose the creation of a distributed electronic health data network among registries. Such a network could support sequential statistical analyses designed to detect early warnings of excess risks. We use a simulated example to explore the circumstances under which a distributed network may prove advantageous. We perform sample size calculations for sequential and non-sequential statistical studies aimed at comparing the incidence of hepatotoxicity following initiation of two newly licensed therapies for homozygous familial hypercholesterolemia. We calculate the sample size savings ratio, or the proportion of sample size saved if one conducted a sequential study as compared to a non-sequential study. Then, using models to describe the adoption and utilization of these therapies, we simulate when these sample sizes are attainable in calendar years. We then calculate the analytic calendar time savings ratio, analogous to the sample size savings ratio. We repeat these analyses for numerous scenarios. Sequential analyses detect effect sizes earlier or at the same time as non-sequential analyses. The most substantial potential savings occur when the market share is more imbalanced (i.e., 90% for therapy A) and the effect size is closest to the null hypothesis. However, due to low exposure prevalence, these savings are difficult to realize within the 30-year time frame of this simulation for scenarios in which the outcome of interest occurs at or more frequently than one event/100 person-years. We illustrate a process to assess whether sequential statistical analyses of registry data performed via distributed networks may prove a worthwhile infrastructure investment for pharmacovigilance.
Multiuser signal detection using sequential decoding
NASA Astrophysics Data System (ADS)
Xie, Zhenhua; Rushforth, Craig K.; Short, Robert T.
1990-05-01
The application of sequential decoding to the detection of data transmitted over the additive white Gaussian noise channel by K asynchronous transmitters using direct-sequence spread-spectrum multiple access is considered. A modification of Fano's (1963) sequential-decoding metric, allowing the messages from a given user to be safely decoded if its Eb/N0 exceeds -1.6 dB, is presented. Computer simulation is used to evaluate the performance of a sequential decoder that uses this metric in conjunction with the stack algorithm. In many circumstances, the sequential decoder achieves results comparable to those obtained using the much more complicated optimal receiver.
Wenz, Holger; Maros, Máté E; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Groden, Christoph; Henzler, Thomas
2016-01-01
To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1-5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1-5) when compared to sequential cCT with a mean SNR improvement of 44.77% (p < 0.0001). Spiral cCT combined with ATCM and IR allows for significant-radiation dose reduction including a reduce eye lens organ-dose when compared to a tilted sequential cCT while improving subjective and objective image quality.
NeCamp, Timothy; Kilbourne, Amy; Almirall, Daniel
2017-08-01
Cluster-level dynamic treatment regimens can be used to guide sequential treatment decision-making at the cluster level in order to improve outcomes at the individual or patient-level. In a cluster-level dynamic treatment regimen, the treatment is potentially adapted and re-adapted over time based on changes in the cluster that could be impacted by prior intervention, including aggregate measures of the individuals or patients that compose it. Cluster-randomized sequential multiple assignment randomized trials can be used to answer multiple open questions preventing scientists from developing high-quality cluster-level dynamic treatment regimens. In a cluster-randomized sequential multiple assignment randomized trial, sequential randomizations occur at the cluster level and outcomes are observed at the individual level. This manuscript makes two contributions to the design and analysis of cluster-randomized sequential multiple assignment randomized trials. First, a weighted least squares regression approach is proposed for comparing the mean of a patient-level outcome between the cluster-level dynamic treatment regimens embedded in a sequential multiple assignment randomized trial. The regression approach facilitates the use of baseline covariates which is often critical in the analysis of cluster-level trials. Second, sample size calculators are derived for two common cluster-randomized sequential multiple assignment randomized trial designs for use when the primary aim is a between-dynamic treatment regimen comparison of the mean of a continuous patient-level outcome. The methods are motivated by the Adaptive Implementation of Effective Programs Trial which is, to our knowledge, the first-ever cluster-randomized sequential multiple assignment randomized trial in psychiatry.
Harari, Colin M.; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T.; Lubner, Meghan G.; Hinshaw, J. Louis; Ziemlewicz, Timothy
2016-01-01
Purpose To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. Materials and Methods All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. Results On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. Conclusion The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015 PMID:26133361
Dong, Angang; Ye, Xingchen; Chen, Jun; Kang, Yijin; Gordon, Thomas; Kikkawa, James M; Murray, Christopher B
2011-02-02
The ability to engineer surface properties of nanocrystals (NCs) is important for various applications, as many of the physical and chemical properties of nanoscale materials are strongly affected by the surface chemistry. Here, we report a facile ligand-exchange approach, which enables sequential surface functionalization and phase transfer of colloidal NCs while preserving the NC size and shape. Nitrosonium tetrafluoroborate (NOBF4) is used to replace the original organic ligands attached to the NC surface, stabilizing the NCs in various polar, hydrophilic media such as N,N-dimethylformamide for years, with no observed aggregation or precipitation. This approach is applicable to various NCs (metal oxides, metals, semiconductors, and dielectrics) of different sizes and shapes. The hydrophilic NCs obtained can subsequently be further functionalized using a variety of capping molecules, imparting different surface functionalization to NCs depending on the molecules employed. Our work provides a versatile ligand-exchange strategy for NC surface functionalization and represents an important step toward controllably engineering the surface properties of NCs.
Yuan, X-G; Zhang, X; Fu, Y-X; Tian, X-F; Liu, Y; Xiao, J; Li, T-W; Qiu, L
2016-05-01
To evaluate the efficacy of a "vacuum sealing drainage (VSD) - artificial dermis implantation (ADI) - thin partial thickness skin grafting (TSG)" sequential therapy for deep and infected wounds in children. Fifty-three pediatric patients with deep and infected wounds were treated with sequential VSD-ADI-TSG therapy. The efficacy of this treatment was compared with that of the surgical debridement-change dressings-thin partial thickness skin grafting previously performed on 20 patients. Survival of tissue grafts, color and flexibility, subcutaneous fullness and scar formation of the graft site were examined and compared. The sequential therapy combined the advantages of the VSD treatment, in reducing tissue necrosis and infection on the wound surfaces and promoting the growth of granulation tissue, with the enhancement of grafting by artificial dermis. Compared with the 20 controls, skin grafted on the artificial dermis was more smooth and glossy, while the textures of the region were more elastic, and the scars were significantly lighter in Vancouver scale. The sequential VSD-ADI-TSG therapy is a simple and effective treatment for children with deep and infected wounds. IV. Copyright © 2016. Published by Elsevier Masson SAS.
Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas
2015-01-01
Objectives To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. Methods 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Results Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (p<0.05). Mean SNR was significantly higher in all spiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05<0.0024). Subjective image quality improved with increasing IR levels. Conclusion Combination of 3rd-generation DSCT spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels. PMID:26288186
Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas
2015-01-01
To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (p<0.05). Mean SNR was significantly higher in all spiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05<0.0024). Subjective image quality improved with increasing IR levels. Combination of 3rd-generation DSCT spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.
A microfluidic device for dry sample preservation in remote settings.
Begolo, Stefano; Shen, Feng; Ismagilov, Rustem F
2013-11-21
This paper describes a microfluidic device for dry preservation of biological specimens at room temperature that incorporates chemical stabilization matrices. Long-term stabilization of samples is crucial for remote medical analysis, biosurveillance, and archiving, but the current paradigm for transporting remotely obtained samples relies on the costly "cold chain" to preserve analytes within biospecimens. We propose an alternative approach that involves the use of microfluidics to preserve samples in the dry state with stabilization matrices, developed by others, that are based on self-preservation chemistries found in nature. We describe a SlipChip-based device that allows minimally trained users to preserve samples with the three simple steps of placing a sample at an inlet, closing a lid, and slipping one layer of the device. The device fills automatically, and a pre-loaded desiccant dries the samples. Later, specimens can be rehydrated and recovered for analysis in a laboratory. This device is portable, compact, and self-contained, so it can be transported and operated by untrained users even in limited-resource settings. Features such as dead-end and sequential filling, combined with a "pumping lid" mechanism, enable precise quantification of the original sample's volume while avoiding overfilling. In addition, we demonstrated that the device can be integrated with a plasma filtration module, and we validated device operations and capabilities by testing the stability of purified RNA solutions. These features and the modularity of this platform (which facilitates integration and simplifies operation) would be applicable to other microfluidic devices beyond this application. We envision that as the field of stabilization matrices develops, microfluidic devices will be useful for cost-effectively facilitating remote analysis and biosurveillance while also opening new opportunities for diagnostics, drug development, and other medical fields.
Simultaneous Versus Sequential Ptosis and Strabismus Surgery in Children.
Revere, Karen E; Binenbaum, Gil; Li, Jonathan; Mills, Monte D; Katowitz, William R; Katowitz, James A
The authors sought to compare the clinical outcomes of simultaneous versus sequential ptosis and strabismus surgery in children. Retrospective, single-center cohort study of children requiring both ptosis and strabismus surgery on the same eye. Simultaneous surgeries were performed during a single anesthetic event; sequential surgeries were performed at least 7 weeks apart. Outcomes were ptosis surgery success (margin reflex distance 1 ≥ 2 mm, good eyelid contour, and good eyelid crease); strabismus surgery success (ocular alignment within 10 prism diopters of orthophoria and/or improved head position); surgical complications; and reoperations. Fifty-six children were studied, 38 had simultaneous surgery and 18 sequential. Strabismus surgery was performed first in 38/38 simultaneous and 6/18 sequential cases. Mean age at first surgery was 64 months, with mean follow up 27 months. A total of 75% of children had congenital ptosis; 64% had comitant strabismus. A majority of ptosis surgeries were frontalis sling (59%) or Fasanella-Servat (30%) procedures. There were no significant differences between simultaneous and sequential groups with regards to surgical success rates, complications, or reoperations (all p > 0.28). In the first comparative study of simultaneous versus sequential ptosis and strabismus surgery, no advantage for sequential surgery was seen. Despite a theoretical risk of postoperative eyelid malposition or complications when surgeries were performed in a combined manner, the rate of such outcomes was not increased with simultaneous surgeries. Performing ptosis and strabismus surgery together appears to be clinically effective and safe, and reduces anesthesia exposure during childhood.
Simultaneous control of microorganisms and disinfection by-products by sequential chlorination.
Chen, Chao; Zhang, Xiao-Jian; He, Wen-Jie; Han, Hong-Da
2007-04-01
To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Pilot tests of this sequential chlorination were carried out in a drinking water plant. The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the free chlorine disinfection process. There seemed to be some synergetic disinfection effect between free chlorine and monochloramine because they attacked different targets. The sequential chlorination disinfection process resulted in 35.7%-77.0% TTHM formation and 36.6%-54.8% THAA5 formation less than the free chlorination process. The poorer the water quality was, the more advantage the sequential chlorination disinfection had over the free chlorination. This process takes advantages of free chlorine's quick inactivation of microorganisms and chloramine's low disinfection by-product (DBP) yield and long-term residual effect, allowing simultaneous control of microbes and DBPs in an effective and economic way.
Kraaijenga, Véronique J C; Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Smit, Adriana L; Stokroos, Robert J; Hendrice, Nadia; Free, Rolien H; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, E A M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko
2017-09-01
To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential BiCIs. A multicenter randomized clinical trial was conducted between January 12, 2010, and September 2, 2012, at 5 tertiary referral centers among 40 participants eligible for BiCIs. Main inclusion criteria were postlingual severe to profound hearing loss, age 18 to 70 years, and a maximum duration of 10 years without hearing aid use in both ears. Data analysis was conducted from May 24 to June 12, 2016. The simultaneous BiCI group received 2 cochlear implants during 1 surgical procedure. The sequential BiCI group received 2 cochlear implants with an interval of 2 years between implants. First, the results 1 year after receiving simultaneous BiCIs were compared with the results 1 year after receiving sequential BiCIs. Second, the results of 3 years of follow-up for both groups were compared separately. The primary outcome measure was speech intelligibility in noise from straight ahead. Secondary outcome measures were speech intelligibility in noise from spatially separated sources, speech intelligibility in silence, localization capabilities, and self-reported benefits assessed with various hearing and quality of life questionnaires. Nineteen participants were randomized to receive simultaneous BiCIs (11 women and 8 men; median age, 52 years [interquartile range, 36-63 years]), and another 19 participants were randomized to undergo sequential BiCIs (8 women and 11 men; median age, 54 years [interquartile range, 43-64 years]). Three patients did not receive a second cochlear implant and were unavailable for follow-up. Comparable results were found 1 year after simultaneous or sequential BiCIs for speech intelligibility in noise from straight ahead (difference, 0.9 dB [95% CI, -3.1 to 4.4 dB]) and all secondary outcome measures except for localization with a 30° angle between loudspeakers (difference, -10% [95% CI, -20.1% to 0.0%]). In the sequential BiCI group, all participants performed significantly better after the BiCIs on speech intelligibility in noise from spatially separated sources and on all localization tests, which was consistent with most of the participants' self-reported hearing capabilities. Speech intelligibility-in-noise results improved in the simultaneous BiCI group up to 3 years following the BiCIs. This study shows comparable objective and subjective hearing results 1 year after receiving simultaneous BiCIs and sequential BiCIs with an interval of 2 years between implants. It also shows a significant benefit of sequential BiCIs over a unilateral cochlear implant. Until 3 years after receiving simultaneous BiCIs, speech intelligibility in noise significantly improved compared with previous years. trialregister.nl Identifier: NTR1722.
Lin, Lu; Wang, Yi-Ning; Kong, Ling-Yan; Jin, Zheng-Yu; Lu, Guang-Ming; Zhang, Zhao-Qi; Cao, Jian; Li, Shuo; Song, Lan; Wang, Zhi-Wei; Zhou, Kang; Wang, Ming
2013-01-01
Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequential scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrillation referred for a second-generation 128-slice DSCT coronary angiography were included in the prospective study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG-triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel-lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each patient were compared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean HR (t=1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by reader1 and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by reader1 and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27±0.19 vs. 1.25±0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively ECG-gated spiral scan, prospectively ECG-triggered sequential DSCT coronary angiography provides similarly diagnostically valuable images in patients with atrial fibrillation and significantly reduces radiation dose.
Zhang, Ying; Ji, Yajie; Li, Jianwei; Lei, Li; Wu, Siyu; Zuo, Wenjia; Jia, Xiaoqing; Wang, Yujie; Mo, Miao; Zhang, Na; Shen, Zhenzhou; Wu, Jiong; Shao, Zhimin; Liu, Guangyu
2018-04-01
To investigate ovarian function and therapeutic efficacy among estrogen receptor (ER)-positive, premenopausal breast cancer patients treated with gonadotropin-releasing hormone agonist (GnRHa) and chemotherapy simultaneously or sequentially. This study was a phase 3, open-label, parallel, randomized controlled trial (NCT01712893). Two hundred sixteen premenopausal patients (under 45 years) diagnosed with invasive ER-positive breast cancer were enrolled from July 2009 to May 2013 and randomized at a 1:1 ratio to receive (neo)adjuvant chemotherapy combined with sequential or simultaneous GnRHa treatment. All patients were advised to receive GnRHa for at least 2 years. The primary outcome was the incidence of early menopause, defined as amenorrhea lasting longer than 12 months after the last chemotherapy or GnRHa dose, with postmenopausal or unknown follicle-stimulating hormone and estradiol levels. The menstrual resumption period and survivals were the secondary endpoints. The median follow-up time was 56.9 months (IQR 49.5-72.4 months). One hundred and eight patients were enrolled in each group. Among them, 92 and 78 patients had complete primary endpoint data in the sequential and simultaneous groups, respectively. The rates of early menopause were 22.8% (21/92) in the sequential group and 23.1% (18/78) in the simultaneous group [simultaneous vs. sequential: OR 1.01 (95% CI 0.50-2.08); p = 0.969; age-adjusted OR 1.13; (95% CI 0.54-2.37); p = 0.737]. The median menstruation resumption period was 12.0 (95% CI 9.3-14.7) months and 10.3 (95% CI 8.2-12.4) months for the sequential and simultaneous groups, respectively [HR 0.83 (95% CI 0.59-1.16); p = 0.274; age-adjusted HR 0.90 (95%CI 0.64-1.27); p = 0.567]. No significant differences were evident for disease-free survival (p = 0.290) or overall survival (p = 0.514) between the two groups. For ER-positive premenopausal patients, the sequential use of GnRHa and chemotherapy showed ovarian preservation and survival outcomes that were no worse than simultaneous use. The application of GnRHa can probably be delayed until menstruation resumption after chemotherapy.
Arend, Carlos Frederico; Arend, Ana Amalia; da Silva, Tiago Rodrigues
2014-06-01
The aim of our study was to systematically compare different methodologies to establish an evidence-based approach based on tendon thickness and structure for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. US was obtained from 164 symptomatic patients with supraspinatus tendinopathy detected at MRI and 42 asymptomatic controls with normal MRI. Diagnostic yield was calculated for either maximal supraspinatus tendon thickness (MSTT) and tendon structure as isolated criteria and using different combinations of parallel and sequential testing at US. Chi-squared tests were performed to assess sensitivity, specificity, and accuracy of different diagnostic approaches. Mean MSTT was 6.68 mm in symptomatic patients and 5.61 mm in asymptomatic controls (P<.05). When used as an isolated criterion, MSTT>6.0mm provided best results for accuracy (93.7%) when compared to other measurements of tendon thickness. Also as an isolated criterion, abnormal tendon structure (ATS) yielded 93.2% accuracy for diagnosis. The best overall yield was obtained by both parallel and sequential testing using either MSTT>6.0mm or ATS as diagnostic criteria at no particular order, which provided 99.0% accuracy, 100% sensitivity, and 95.2% specificity. Among these parallel and sequential tests that provided best overall yield, additional analysis revealed that sequential testing first evaluating tendon structure required assessment of 258 criteria (vs. 261 for sequential testing first evaluating tendon thickness and 412 for parallel testing) and demanded a mean of 16.1s to assess diagnostic criteria and reach the diagnosis (vs. 43.3s for sequential testing first evaluating tendon thickness and 47.4s for parallel testing). We found that using either MSTT>6.0mm or ATS as diagnostic criteria for both parallel and sequential testing provides the best overall yield for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. Among these strategies, a two-step sequential approach first assessing tendon structure was advantageous because it required a lower number of criteria to be assessed and demanded less time to assess diagnostic criteria and reach the diagnosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Doyle, William J; Singla, Alok; Banks, Juliane; El-Wagaa, Jenna; Swarts, J Douglas
2014-07-01
Fractional gradient equilibrated (FGE) for ears with applied positive but not negative middle ear (ME)-ambient pressure gradients is highly sensitive to a cold-like illness (CLI). The sequential development of eustachian tube (ET) dysfunction, ME under-pressure, and otitis media (OM) characterizes many children during a CLI. If linked, OM burden would be lessened by interventions that promote/preserve good ET function during a CLI. Evaluating this requires a quantitative ET function test for MEs with an intact tympanic membrane responsive to a CLI. Pressure chamber testing of ET function was performed at +200 and -200 daPa in 3 groups of adults: group I, 21 subjects with an extant CLI and groups II and III, 14 and 57 adults, respectively, without a CLI. ME-chamber pressure gradient was recorded by tympanometry before and after the subject swallowed twice. ET functional efficiency was quantified as the FGE, which was then compared among groups using a Mann-Whitney U test. At chamber pressures of 200 daPa, the ME-chamber pressure gradient was negative, and FGE was low and not different among groups. At chamber pressures of -200 daPa that gradient was positive, and FGE was significantly higher in groups II and III when compared with group I.
Mohamed, Ryian; Gadhvi, Kunal; Mensah, Evelyn
2018-05-30
To compare, in a single urban population, the visual outcomes of ranibizumab monotherapy in "White" (W) and "Non-White" (NW) patients with wet age-related macular degeneration (AMD). Prospective data was collected from 434 eyes of 217 patients with wet AMD patients receiving intravitreal ranibizumab. Baseline and monthly LogMAR visual acuities were obtained. All patients received treatment under a "treat and extend policy" consisting of three monthly injections of ranibizumab, followed by individualised sequentially lengthening follow-up intervals when stable. At 24 months, the percentage of eyes that maintained or improved vision was 91% in W patients and 83% in NW patients. Correspondingly, at 24 months, the percentage of visual loss was 9% for W patients and 17% of NW patients. We found that whilst W patients required fewer overall injections (14.1) they gained an average 4 LogMAR letters of visual acuity. However, NW patients required more injections (14.6) to gain 0.5 LogMAR letters of visual acuity over the same 24 months of treatment. Individualised ranibizumab monotherapy is more effective in preserving vision for W compared to NW patients with wet AMD. © 2018 S. Karger AG, Basel.
Salter-Venzon, Dawna; Kazlova, Valentina; Izzy Ford, Samantha; Intra, Janjira; Klosner, Allison E; Gellenbeck, Kevin W
2017-05-01
Despite the notable health benefits of carotenoids for human health, the majority of human diets worldwide are repeatedly shown to be inadequate in intake of carotenoid-rich fruits and vegetables, according to current health recommendations. To address this deficit, strategies designed to increase dietary intakes and subsequent plasma levels of carotenoids are warranted. When mixed carotenoids are delivered into the intestinal tract simultaneously, competition occurs for micelle formation and absorption, affecting carotenoid bioavailability. Previously, we tested the in vitro viability of a carotenoid mix designed to deliver individual carotenoids sequentially spaced from one another over the 6 hr transit time of the human upper gastrointestinal system. We hypothesized that temporally and spatially separating the individual carotenoids would reduce competition for micelle formation, improve uptake, and maximize efficacy. Here, we test this hypothesis in a double-blind, repeated-measure, cross-over human study with 12 subjects by comparing the change of plasma carotenoid levels for 8 hr after oral doses of a sequentially spaced carotenoid mix, to a matched mix without sequential spacing. We find the carotenoid change from baseline, measured as area under the curve, is increased following consumption of the sequentially spaced mix compared to concomitant carotenoids delivery. These results demonstrate reduced interaction and regulation between the sequentially spaced carotenoids, suggesting improved bioavailability from a novel sequentially spaced carotenoid mix.
Bansal, A; Kapoor, R; Singh, S K; Kumar, N; Oinam, A S; Sharma, S C
2012-07-01
DOSIMETERIC AND RADIOBIOLOGICAL COMPARISON OF TWO RADIATION SCHEDULES IN LOCALIZED CARCINOMA PROSTATE: Standard Three-Dimensional Conformal Radiotherapy (3DCRT) followed by Intensity Modulated Radiotherapy (IMRT) boost (sequential-IMRT) with Simultaneous Integrated Boost IMRT (SIB-IMRT). Thirty patients were enrolled. In all, the target consisted of PTV P + SV (Prostate and seminal vesicles) and PTV LN (lymph nodes) where PTV refers to planning target volume and the critical structures included: bladder, rectum and small bowel. All patients were treated with sequential-IMRT plan, but for dosimetric comparison, SIB-IMRT plan was also created. The prescription dose to PTV P + SV was 74 Gy in both strategies but with different dose per fraction, however, the dose to PTV LN was 50 Gy delivered in 25 fractions over 5 weeks for sequential-IMRT and 54 Gy delivered in 27 fractions over 5.5 weeks for SIB-IMRT. The treatment plans were compared in terms of dose-volume histograms. Also, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) obtained with the two plans were compared. The volume of rectum receiving 70 Gy or more (V > 70 Gy) was reduced to 18.23% with SIB-IMRT from 22.81% with sequential-IMRT. SIB-IMRT reduced the mean doses to both bladder and rectum by 13% and 17%, respectively, as compared to sequential-IMRT. NTCP of 0.86 ± 0.75% and 0.01 ± 0.02% for the bladder, 5.87 ± 2.58% and 4.31 ± 2.61% for the rectum and 8.83 ± 7.08% and 8.25 ± 7.98% for the bowel was seen with sequential-IMRT and SIB-IMRT plans respectively. For equal PTV coverage, SIB-IMRT markedly reduced doses to critical structures, therefore should be considered as the strategy for dose escalation. SIB-IMRT achieves lesser NTCP than sequential-IMRT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merkel, K.D.; Brown, M.L.; Dewanjee, M.K.
We prospectively compared sequential technetium-gallium imaging with indium-labeled-leukocyte imaging in fifty patients with suspected low-grade musculoskeletal sepsis. Adequate images and follow-up examinations were obtained for forty-two patients. The presence or absence of low-grade sepsis was confirmed by histological and bacteriological examinations of tissue specimens taken at surgery in thirty of the forty-two patients. In these thirty patients, the sensitivity of sequential Tc-Ga imaging was 48 per cent, the specificity was 86 per cent, and the accuracy was 57 per cent, whereas the sensitivity of the indium-labeled-leukocyte technique was 83 per cent, the specificity was 86 per cent, and the accuracymore » was 83 per cent. When the additional twelve patients for whom surgery was deemed unnecessary were considered, the sensitivity of sequential Tc-Ga imaging was 50 per cent, the specificity was 78 per cent, and the accuracy was 62 per cent, as compared with a sensitivity of 83 per cent, a specificity of 94 per cent, and an accuracy of 88 per cent with the indium-labeled-leukocyte method. In patients with a prosthesis the indium-labeled-leukocyte image was 94 per cent accurate, compared with 75 per cent accuracy for sequential Tc-Ga imaging. Statistical analysis of these data demonstrated that the indium-labeled-leukocyte technique was superior to sequential Tc-Ga imaging in detecting areas of low-grade musculoskeletal sepsis.« less
Flowe, Heather D; Ebbesen, Ebbe B
2007-02-01
Two experiments investigated whether remembering is affected by the similarity of the study face relative to the alternatives in a lineup. In simultaneous and sequential lineups, choice rates and false alarms were larger in low compared to high similarity lineups, indicating criterion placement was affected by lineup similarity structure (Experiment 1). In Experiment 2, foil choices and similarity ranking data for target present lineups were compared to responses made when the target was removed from the lineup (only the 5 foils were presented). The results indicated that although foils were selected more often in target-removed lineups in the simultaneous compared to the sequential condition, responses shifted from the target to one of the foils at equal rates across lineup procedures.
Inoue, Tadahisa; Ishii, Norimitsu; Kobayashi, Yuji; Kitano, Rena; Sakamoto, Kazumasa; Ohashi, Tomohiko; Nakade, Yukiomi; Sumida, Yoshio; Ito, Kiyoaki; Nakao, Haruhisa; Yoneda, Masashi
2017-09-01
Endoscopic bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstructions (MHBOs) is technically demanding, and a second SEMS insertion is particularly challenging. A simultaneous side-by-side (SBS) placement technique using a thinner delivery system may mitigate these issues. We aimed to examine the feasibility and efficacy of simultaneous SBS SEMS placement for treating MHBOs using a novel SEMS that has a 5.7-Fr ultra-thin delivery system. Thirty-four patients with MHBOs underwent SBS SEMS placement between 2010 and 2016. We divided the patient cohort into those who underwent sequential (conventional) SBS placement between 2010 and 2014 (sequential group) and those who underwent simultaneous SBS placement between 2015 and 2016 (simultaneous group), and compared the groups with respect to the clinical outcomes. The technical success rates were 71% (12/17) and 100% (17/17) in the sequential and simultaneous groups, respectively, a difference that was significant (P = .045). The median procedure time was significantly shorter in the simultaneous group (22 min) than in the sequential group (52 min) (P = .017). There were no significant group differences in the time to recurrent biliary obstruction (sequential group: 113 days; simultaneous group: 140 days) or other adverse event rates (sequential group: 12%; simultaneous group: 12%). Simultaneous SBS placement using the novel 5.7-Fr SEMS delivery system may be more straightforward and have a higher success rate compared to that with sequential SBS placement. This new method may be useful for bilateral stenting to treat MHBOs.
Cyclosporine A or intravenous cyclophosphamide for lupus nephritis: the Cyclofa-Lune study.
Zavada, J; Pesickova, Ss; Rysava, R; Olejarova, M; Horák, P; Hrncír, Z; Rychlík, I; Havrda, M; Vítova, J; Lukác, J; Rovensky, J; Tegzova, D; Böhmova, J; Zadrazil, J; Hána, J; Dostál, C; Tesar, V
2010-10-01
Intravenous cyclophosphamide is considered to be the standard of care for the treatment of proliferative lupus nephritis. However, its use is limited by potentially severe toxic effects. Cyclosporine A has been suggested to be an efficient and safe treatment alternative to cyclophosphamide. Forty patients with clinically active proliferative lupus nephritis were randomly assigned to one of two sequential induction and maintenance treatment regimens based either on cyclophosphamide or Cyclosporine A. The primary outcomes were remission (defined as normal urinary sediment, proteinuria <0.3 g/24 h, and stable s-creatinine) and response to therapy (defined as stable s-creatinine, 50% reduction in proteinuria, and either normalization of urinary sediment or significant improvement in C3) at the end of induction and maintenance phase. Secondary outcomes were incidence of adverse events, and relapse-free survival. At the end of the induction phase, 24% of the 21 patients treated by cyclophosphamide achieved remission, and 52% achieved response, as compared with 26% and 43%, respectively of the 19 patients treated by the Cyclosporine A. At the end of the maintenance phase, 14% of patients in cyclophosphamide group, and 37% in Cyclosporine A group had remission, and 38% and 58% respectively response. Treatment with Cyclosporine A was associated with transient increase in blood pressure and reversible decrease in glomerular filtration rate. There was no significant difference in median relapse-free survival. In conclusion, Cyclosporine A was as effective as cyclophosphamide in the trial of sequential induction and maintenance treatment in patients with proliferative lupus nephritis and preserved renal function.(ClinicalTrials.gov identifier: NCT00976300)
Zhu, Jundong; Jiang, Fan; Li, Pu; Shao, Pengfei; Liang, Chao; Xu, Aiming; Miao, Chenkui; Qin, Chao; Wang, Zengjun; Yin, Changjun
2017-09-11
To explore the feasibility and safety of retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping for the patients with multiple renal tumor of who have solitary kidney or contralateral kidney insufficiency. Nine patients who have undergone retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping between October 2010 and January 2017 were retrospectively analyzed. Clinical materials and parameters during and after the operation were summarized. Nineteen tumors were resected in nine patients and the operations were all successful. The operation time ranged from 100 to 180 min (125 min); clamping time of segmental renal artery was 10 ~ 30 min (23 min); the amount of blood loss during the operation was 120 ~ 330 ml (190 ml); hospital stay after the operation is 3 ~ 6d (5d). There was no complication during the perioperative period, and the pathology diagnosis after the surgery showed that there were 13 renal clear cell carcinomas, two papillary carcinoma and four perivascular epithelioid cell tumors with negative margins from the 19 tumors. All patients were followed up for 3 ~ 60 months, and no local recurrence or metastasis was detected. At 3-month post-operation follow-up, the mean serum creatinine was 148.6 ± 28.1 μmol/L (p = 0.107), an increase of 3.0 μmol/L from preoperative baseline. For the patients with multiple renal tumors and solitary kidney or contralateral kidney insufficiency, retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping was feasible and safe, which minimized the warm ischemia injury to the kidney and preserved the renal function effectively.
Increased Automaticity and Altered Temporal Preparation Following Sleep Deprivation.
Kong, Danyang; Asplund, Christopher L; Ling, Aiqing; Chee, Michael W L
2015-08-01
Temporal expectation enables us to focus limited processing resources, thereby optimizing perceptual and motor processing for critical upcoming events. We investigated the effects of total sleep deprivation (TSD) on temporal expectation by evaluating the foreperiod and sequential effects during a psychomotor vigilance task (PVT). We also examined how these two measures were modulated by vulnerability to TSD. Three 10-min visual PVT sessions using uniformly distributed foreperiods were conducted in the wake-maintenance zone the evening before sleep deprivation (ESD) and three more in the morning following approximately 22 h of TSD. TSD vulnerable and nonvulnerable groups were determined by a tertile split of participants based on the change in the number of behavioral lapses recorded during ESD and TSD. A subset of participants performed six additional 10-min modified auditory PVTs with exponentially distributed foreperiods during rested wakefulness (RW) and TSD to test the effect of temporal distribution on foreperiod and sequential effects. Sleep laboratory. There were 172 young healthy participants (90 males) with regular sleep patterns. Nineteen of these participants performed the modified auditory PVT. Despite behavioral lapses and slower response times, sleep deprived participants could still perceive the conditional probability of temporal events and modify their level of preparation accordingly. Both foreperiod and sequential effects were magnified following sleep deprivation in vulnerable individuals. Only the foreperiod effect increased in nonvulnerable individuals. The preservation of foreperiod and sequential effects suggests that implicit time perception and temporal preparedness are intact during total sleep deprivation. Individuals appear to reallocate their depleted preparatory resources to more probable event timings in ongoing trials, whereas vulnerable participants also rely more on automatic processes. © 2015 Associated Professional Sleep Societies, LLC.
SPMBR: a scalable algorithm for mining sequential patterns based on bitmaps
NASA Astrophysics Data System (ADS)
Xu, Xiwei; Zhang, Changhai
2013-12-01
Now some sequential patterns mining algorithms generate too many candidate sequences, and increase the processing cost of support counting. Therefore, we present an effective and scalable algorithm called SPMBR (Sequential Patterns Mining based on Bitmap Representation) to solve the problem of mining the sequential patterns for large databases. Our method differs from previous related works of mining sequential patterns. The main difference is that the database of sequential patterns is represented by bitmaps, and a simplified bitmap structure is presented firstly. In this paper, First the algorithm generate candidate sequences by SE(Sequence Extension) and IE(Item Extension), and then obtain all frequent sequences by comparing the original bitmap and the extended item bitmap .This method could simplify the problem of mining the sequential patterns and avoid the high processing cost of support counting. Both theories and experiments indicate that the performance of SPMBR is predominant for large transaction databases, the required memory size for storing temporal data is much less during mining process, and all sequential patterns can be mined with feasibility.
Lee, Hyuk; Hong, Sung Noh; Min, Byung-Hoon; Lee, Jun Haeng; Rhee, Poong-Lyul; Lee, Yong Chan; Kim, Jae J
2015-02-01
Declining of eradication rates for Helicobacter pylori in Korea may be partly from the increasing prevalence of antibiotic resistance, especially clarithromycin resistance. To compare the efficacy and the safety of using 10-day standard sequential therapy and levofloxacin-containing sequential therapy as a first-line treatment for Helicobacter pylori eradication in Korea. A total of 200 patients with proven Helicobacter pylori infection randomly received 10-day standard sequential therapy (n = 100) or levofloxacin-containing sequential therapy (n = 100). The standard sequential therapy group received rabeprazole and amoxicillin for 5 days, followed by rabeprazole, clarithromycin, and metronidazole for 5 more days. The levofloxacin-containing sequential therapy group was treated with rabeprazole and amoxicillin for 5 days, followed by rabeprazole, levofloxacin, and metronidazole for 5 more days. Intention-to-treat eradication rates were 79.0% and 78.0% for groups of standard sequential and levofloxacin-containing sequential therapy, respectively (P = 0.863). Per-protocol eradication rates were 84.9% and 81.3%, respectively, for these two therapies (P = 0.498). There were no significant differences between the groups in regard to the eradication rates and adverse events. The 10-day levofloxacin-containing sequential regimen and the standard sequential regimen showed the similar eradication rates of Helicobacter pylori in Korea. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Pooler, B Dustin; Hernando, Diego; Ruby, Jeannine A; Ishii, Hiroshi; Shimakawa, Ann; Reeder, Scott B
2018-04-17
Current chemical-shift-encoded (CSE) MRI techniques for measuring hepatic proton density fat fraction (PDFF) are sensitive to motion artifacts. Initial validation of a motion-robust 2D-sequential CSE-MRI technique for quantification of hepatic PDFF. Phantom study and prospective in vivo cohort. Fifty adult patients (27 women, 23 men, mean age 57.2 years). 3D, 2D-interleaved, and 2D-sequential CSE-MRI acquisitions at 1.5T. Three CSE-MRI techniques (3D, 2D-interleaved, 2D-sequential) were performed in a PDFF phantom and in vivo. Reference standards were 3D CSE-MRI PDFF measurements for the phantom study and single-voxel MR spectroscopy hepatic PDFF measurements (MRS-PDFF) in vivo. In vivo hepatic MRI-PDFF measurements were performed during a single breath-hold (BH) and free breathing (FB), and were repeated by a second reader for the FB 2D-sequential sequence to assess interreader variability. Correlation plots to validate the 2D-sequential CSE-MRI against the phantom and in vivo reference standards. Bland-Altman analysis of FB versus BH CSE-MRI acquisitions to evaluate robustness to motion. Bland-Altman analysis to assess interreader variability. Phantom 2D-sequential CSE-MRI PDFF measurements demonstrated excellent agreement and correlation (R 2 > 0.99) with 3D CSE-MRI. In vivo, the mean (±SD) hepatic PDFF was 8.8 ± 8.7% (range 0.6-28.5%). Compared with BH acquisitions, FB hepatic PDFF measurements demonstrated bias of +0.15% for 2D-sequential compared with + 0.53% for 3D and +0.94% for 2D-interleaved. 95% limits of agreement (LOA) were narrower for 2D-sequential (±0.99%), compared with 3D (±3.72%) and 2D-interleaved (±3.10%). All CSE-MRI techniques had excellent correlation with MRS (R 2 > 0.97). The FB 2D-sequential acquisition demonstrated little interreader variability, with mean bias of +0.07% and 95% LOA of ± 1.53%. This motion-robust 2D-sequential CSE-MRI can accurately measure hepatic PDFF during free breathing in a patient population with a range of PDFF values of 0.6-28.5%, permitting accurate quantification of liver fat content without the need for suspended respiration. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
A sampling and classification item selection approach with content balancing.
Chen, Pei-Hua
2015-03-01
Existing automated test assembly methods typically employ constrained combinatorial optimization. Constructing forms sequentially based on an optimization approach usually results in unparallel forms and requires heuristic modifications. Methods based on a random search approach have the major advantage of producing parallel forms sequentially without further adjustment. This study incorporated a flexible content-balancing element into the statistical perspective item selection method of the cell-only method (Chen et al. in Educational and Psychological Measurement, 72(6), 933-953, 2012). The new method was compared with a sequential interitem distance weighted deviation model (IID WDM) (Swanson & Stocking in Applied Psychological Measurement, 17(2), 151-166, 1993), a simultaneous IID WDM, and a big-shadow-test mixed integer programming (BST MIP) method to construct multiple parallel forms based on matching a reference form item-by-item. The results showed that the cell-only method with content balancing and the sequential and simultaneous versions of IID WDM yielded results comparable to those obtained using the BST MIP method. The cell-only method with content balancing is computationally less intensive than the sequential and simultaneous versions of IID WDM.
Qin, Fangjun; Chang, Lubin; Jiang, Sai; Zha, Feng
2018-05-03
In this paper, a sequential multiplicative extended Kalman filter (SMEKF) is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms.
A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations
Qin, Fangjun; Jiang, Sai; Zha, Feng
2018-01-01
In this paper, a sequential multiplicative extended Kalman filter (SMEKF) is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms. PMID:29751538
ERIC Educational Resources Information Center
Green, Samuel B.; Thompson, Marilyn S.; Levy, Roy; Lo, Wen-Juo
2015-01-01
Traditional parallel analysis (T-PA) estimates the number of factors by sequentially comparing sample eigenvalues with eigenvalues for randomly generated data. Revised parallel analysis (R-PA) sequentially compares the "k"th eigenvalue for sample data to the "k"th eigenvalue for generated data sets, conditioned on"k"-…
Optimal sequential measurements for bipartite state discrimination
NASA Astrophysics Data System (ADS)
Croke, Sarah; Barnett, Stephen M.; Weir, Graeme
2017-05-01
State discrimination is a useful test problem with which to clarify the power and limitations of different classes of measurement. We consider the problem of discriminating between given states of a bipartite quantum system via sequential measurement of the subsystems, with classical feed-forward of measurement results. Our aim is to understand when sequential measurements, which are relatively easy to implement experimentally, perform as well, or almost as well, as optimal joint measurements, which are in general more technologically challenging. We construct conditions that the optimal sequential measurement must satisfy, analogous to the well-known Helstrom conditions for minimum error discrimination in the unrestricted case. We give several examples and compare the optimal probability of correctly identifying the state via global versus sequential measurement strategies.
Competing Classical and Quantum Effects in Shape Relaxation of a Metallic Island
NASA Technical Reports Server (NTRS)
Okamoto, Rowland H.; Chen, D.; Yamada, T.
2002-01-01
Pb islands grown on a silicon substrate transform at room temperature from the initially flattop facet geometry into an unusual ring, shape with a volume-preserving mass transport process catalysed by the tip electrical field of a scanning tunnelling microscope. The formation of such ring shape morphology results from the competing classical and quantum effects in the shape relaxation. The latter also leads to a sequential regrowth on alternating, strips of the same facet defined by the underlying substrate steps, showing for the first time the dynamical impact of the quantum size effect on the stability of a nanostructure.
Habitual control of goal selection in humans
Cushman, Fiery; Morris, Adam
2015-01-01
Humans choose actions based on both habit and planning. Habitual control is computationally frugal but adapts slowly to novel circumstances, whereas planning is computationally expensive but can adapt swiftly. Current research emphasizes the competition between habits and plans for behavioral control, yet many complex tasks instead favor their integration. We consider a hierarchical architecture that exploits the computational efficiency of habitual control to select goals while preserving the flexibility of planning to achieve those goals. We formalize this mechanism in a reinforcement learning setting, illustrate its costs and benefits, and experimentally demonstrate its spontaneous application in a sequential decision-making task. PMID:26460050
Ceschin, Ianae I; Ribas, Mariana H; Ceschin, Alvaro P; Nishikawa, Lucileine; Rocha, Claudia C; Pic-Taylor, Aline; Baroneza, José Eduardo
2016-03-01
To check the efficacy of two types of commercially available embryo culture medium: G1-PLUS™/G2-PLUS™ sequential (Vitrolife, Gothenburg, Sweden) and GV BLAST™ sole (Ingamed, Maringá, Brazil) with regards to fertilization, cleavage, blastocyst and pregnancy rates. Prospective and randomized study conducted from March to July 2015, using the medical records of 60 patients submitted to Intracytoplasmic Sperm Injection techniques (ICSI). Data regarding the age of patients, together with fertilization, cleavage, blastocyst and pregnancy rates, were collected and compared in relation to the: G1-PLUS™/G2-PLUS™ sequential and GV BLAST™ sole mediums. The data were tabulated and compared using the Pearson's Chi-Square test (95% CI). There was no significant difference when comparing patients divided into higher and lower fertility age. No significant statistical difference was noted between the fertilization rates (P=0.59), cleavage (P=0.91), evolution to blastocyst (P=0.33) and total pregnancy (P=0.83) when comparing the embryos cultured in the different media analysed. We conclude that the G1-PLUS™/G2-PLUS™ sequential and GV BLAST™ sole mediums are equally effective with regards to fertilization, cleavage, blastocyst development and total pregnancy rates.
PC_Eyewitness and the sequential superiority effect: computer-based lineup administration.
MacLin, Otto H; Zimmerman, Laura A; Malpass, Roy S
2005-06-01
Computer technology has become an increasingly important tool for conducting eyewitness identifications. In the area of lineup identifications, computerized administration offers several advantages for researchers and law enforcement. PC_Eyewitness is designed specifically to administer lineups. To assess this new lineup technology, two studies were conducted in order to replicate the results of previous studies comparing simultaneous and sequential lineups. One hundred twenty university students participated in each experiment. Experiment 1 used traditional paper-and-pencil lineup administration methods to compare simultaneous to sequential lineups. Experiment 2 used PC_Eyewitness to administer simultaneous and sequential lineups. The results of these studies were compared to the meta-analytic results reported by N. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001). No differences were found between paper-and-pencil and PC_Eyewitness lineup administration methods. The core findings of the N. Steblay et al. (2001) meta-analysis were replicated by both administration procedures. These results show that computerized lineup administration using PC_Eyewitness is an effective means for gathering eyewitness identification data.
Shteingart, Hanan; Loewenstein, Yonatan
2016-01-01
There is a long history of experiments in which participants are instructed to generate a long sequence of binary random numbers. The scope of this line of research has shifted over the years from identifying the basic psychological principles and/or the heuristics that lead to deviations from randomness, to one of predicting future choices. In this paper, we used generalized linear regression and the framework of Reinforcement Learning in order to address both points. In particular, we used logistic regression analysis in order to characterize the temporal sequence of participants' choices. Surprisingly, a population analysis indicated that the contribution of the most recent trial has only a weak effect on behavior, compared to more preceding trials, a result that seems irreconcilable with standard sequential effects that decay monotonously with the delay. However, when considering each participant separately, we found that the magnitudes of the sequential effect are a monotonous decreasing function of the delay, yet these individual sequential effects are largely averaged out in a population analysis because of heterogeneity. The substantial behavioral heterogeneity in this task is further demonstrated quantitatively by considering the predictive power of the model. We show that a heterogeneous model of sequential dependencies captures the structure available in random sequence generation. Finally, we show that the results of the logistic regression analysis can be interpreted in the framework of reinforcement learning, allowing us to compare the sequential effects in the random sequence generation task to those in an operant learning task. We show that in contrast to the random sequence generation task, sequential effects in operant learning are far more homogenous across the population. These results suggest that in the random sequence generation task, different participants adopt different cognitive strategies to suppress sequential dependencies when generating the "random" sequences.
Reducing noise component on medical images
NASA Astrophysics Data System (ADS)
Semenishchev, Evgeny; Voronin, Viacheslav; Dub, Vladimir; Balabaeva, Oksana
2018-04-01
Medical visualization and analysis of medical data is an actual direction. Medical images are used in microbiology, genetics, roentgenology, oncology, surgery, ophthalmology, etc. Initial data processing is a major step towards obtaining a good diagnostic result. The paper considers the approach allows an image filtering with preservation of objects borders. The algorithm proposed in this paper is based on sequential data processing. At the first stage, local areas are determined, for this purpose the method of threshold processing, as well as the classical ICI algorithm, is applied. The second stage uses a method based on based on two criteria, namely, L2 norm and the first order square difference. To preserve the boundaries of objects, we will process the transition boundary and local neighborhood the filtering algorithm with a fixed-coefficient. For example, reconstructed images of CT, x-ray, and microbiological studies are shown. The test images show the effectiveness of the proposed algorithm. This shows the applicability of analysis many medical imaging applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoupin, Stanislav; Antipov, Sergey; Butler, James E.
Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configurationmore » and data analysis using rocking-curve topography. In conclusion, the variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.« less
Stoupin, Stanislav; Antipov, Sergey; Butler, James E; Kolyadin, Alexander V; Katrusha, Andrey
2016-09-01
Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking-curve topography. The variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.
Characteristics of ballistic and blast injuries.
Powers, David B; Delo, Robert I
2013-03-01
Ballistic injury wounds are formed by variable interrelated factors, such as the nature of the tissue, the compositional makeup of the bullet, distance to the target, and the velocity, shape, and mass of the of the projectile. This complex arrangement, with the ultimate outcome dependent on each other, makes the prediction of wounding potential difficult to assess. As the facial features are the component of the body most involved in a patient's personality and interaction with society, preservation of form, cosmesis, and functional outcome should remain the primary goals in the management of ballistic injury. A logical, sequential analysis of the injury patterns to the facial complex is an absolutely necessary component for the treatment of craniomaxillofacial ballistic injuries. Fortunately, these skill sets should be well honed in all craniomaxillofacial surgeons through their exposure to generalized trauma, orthognathic, oncologic, and cosmetic surgery patients. Identification of injured tissues, understanding the functional limitations of these injuries, and preservation of both hard and soft tissues minimizing the need for tissue replacement are paramount.
Manucharova, N A; Trosheva, E V; Kol'tsova, E M; Demkina, E V; Karaevskaya, E V; Rivkina, E M; Mardanov, A V; El'-Registan, G I
2016-01-01
A prokaryotic mesophilic organotrophic community responsible for 10% of the total microbial number determined by epifluorescence microscopy was reactivated in the samples ofAntarctic permafrost retrieved from the environment favoring long-term preservation of microbial communities (7500 years). No culturable forms were obtained without resuscitation procedures (CFU = 0). Proteobacteria, Actinobacteria, and Firmicutes were the dominant microbial groups in the complex. Initiation of the reactivated microbial complex by addition of chitin (0.1% wt/vol) resulted in an increased share of metabolically active biomass (up to 50%) due to the functional domination of chitinolytics caused by the target resource. Thus, sequential application of resuscitation procedures and initiation of a specific physiological group (in this case, chitinolytics) to a permafrost-preserved microbial community made it possible to reveal a prokaryotic complex capable of reversion of metabolic activity (FISH data), to determine its phylogenetic structure by metagenomic anal-ysis, and to isolate a pure culture of the dominant microorganism with high chitinolytic activity.
Stoupin, Stanislav; Antipov, Sergey; Butler, James E.; ...
2016-08-10
Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configurationmore » and data analysis using rocking-curve topography. In conclusion, the variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.« less
Haptoglobin Preserves Vascular Nitric Oxide Signaling during Hemolysis.
Schaer, Christian A; Deuel, Jeremy W; Schildknecht, Daniela; Mahmoudi, Leila; Garcia-Rubio, Ines; Owczarek, Catherine; Schauer, Stefan; Kissner, Reinhard; Banerjee, Uddyalok; Palmer, Andre F; Spahn, Donat R; Irwin, David C; Vallelian, Florence; Buehler, Paul W; Schaer, Dominik J
2016-05-15
Hemolysis occurs not only in conditions such as sickle cell disease and malaria but also during transfusion of stored blood, extracorporeal circulation, and sepsis. Cell-free Hb depletes nitric oxide (NO) in the vasculature, causing vasoconstriction and eventually cardiovascular complications. We hypothesize that Hb-binding proteins may preserve vascular NO signaling during hemolysis. Characterization of an archetypical function by which Hb scavenger proteins could preserve NO signaling during hemolysis. We investigated NO reaction kinetics, effects on arterial NO signaling, and tissue distribution of cell-free Hb and its scavenger protein complexes. Extravascular translocation of cell-free Hb into interstitial spaces, including the vascular smooth muscle cell layer of rat and pig coronary arteries, promotes vascular NO resistance. This critical disease process is blocked by haptoglobin. Haptoglobin does not change NO dioxygenation rates of Hb; rather, the large size of the Hb:haptoglobin complex prevents Hb extravasation, which uncouples NO/Hb interaction and vasoconstriction. Size-selective compartmentalization of Hb functions as a substitute for red blood cells after hemolysis and preserves NO signaling in the vasculature. We found that evolutionarily and structurally unrelated Hb-binding proteins, such as PIT54 found in avian species, functionally converged with haptoglobin to protect NO signaling by sequestering cell-free Hb in large protein complexes. Sequential compartmentalization of Hb by erythrocytes and scavenger protein complexes is an archetypical mechanism, which may have supported coevolution of hemolysis and normal vascular function. Therapeutic supplementation of Hb scavengers may restore vascular NO signaling and attenuate disease complications in patients with hemolysis.
de Oliveira, Saulo H P; Law, Eleanor C; Shi, Jiye; Deane, Charlotte M
2018-04-01
Most current de novo structure prediction methods randomly sample protein conformations and thus require large amounts of computational resource. Here, we consider a sequential sampling strategy, building on ideas from recent experimental work which shows that many proteins fold cotranslationally. We have investigated whether a pseudo-greedy search approach, which begins sequentially from one of the termini, can improve the performance and accuracy of de novo protein structure prediction. We observed that our sequential approach converges when fewer than 20 000 decoys have been produced, fewer than commonly expected. Using our software, SAINT2, we also compared the run time and quality of models produced in a sequential fashion against a standard, non-sequential approach. Sequential prediction produces an individual decoy 1.5-2.5 times faster than non-sequential prediction. When considering the quality of the best model, sequential prediction led to a better model being produced for 31 out of 41 soluble protein validation cases and for 18 out of 24 transmembrane protein cases. Correct models (TM-Score > 0.5) were produced for 29 of these cases by the sequential mode and for only 22 by the non-sequential mode. Our comparison reveals that a sequential search strategy can be used to drastically reduce computational time of de novo protein structure prediction and improve accuracy. Data are available for download from: http://opig.stats.ox.ac.uk/resources. SAINT2 is available for download from: https://github.com/sauloho/SAINT2. saulo.deoliveira@dtc.ox.ac.uk. Supplementary data are available at Bioinformatics online.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shusharina, N; Khan, F; Sharp, G
Purpose: To determine the dose level and timing of the boost in locally advanced lung cancer patients with confirmed tumor recurrence by comparing different boosting strategies by an impact of dose escalation in improvement of the therapeutic ratio. Methods: We selected eighteen patients with advanced NSCLC and confirmed recurrence. For each patient, a base IMRT plan to 60 Gy prescribed to PTV was created. Then we compared three dose escalation strategies: a uniform escalation to the original PTV, an escalation to a PET-defined target planned sequentially and concurrently. The PET-defined targets were delineated by biologically-weighed regions on a pre-treatment 18F-FDGmore » PET. The maximal achievable dose, without violating the OAR constraints, was identified for each boosting method. The EUD for the target, spinal cord, combined lung, and esophagus was compared for each plan. Results: The average prescribed dose was 70.4±13.9 Gy for the uniform boost, 88.5±15.9 Gy for the sequential boost and 89.1±16.5 Gy for concurrent boost. The size of the boost planning volume was 12.8% (range: 1.4 – 27.9%) of the PTV. The most prescription-limiting dose constraints was the V70 of the esophagus. The EUD within the target increased by 10.6 Gy for the uniform boost, by 31.4 Gy for the sequential boost and by 38.2 for the concurrent boost. The EUD for OARs increased by the following amounts: spinal cord, 3.1 Gy for uniform boost, 2.8 Gy for sequential boost, 5.8 Gy for concurrent boost; combined lung, 1.6 Gy for uniform, 1.1 Gy for sequential, 2.8 Gy for concurrent; esophagus, 4.2 Gy for uniform, 1.3 Gy for sequential, 5.6 Gy for concurrent. Conclusion: Dose escalation to a biologically-weighed gross tumor volume defined on a pre-treatment 18F-FDG PET may provide improved therapeutic ratio without breaching predefined OAR constraints. Sequential boost provides better sparing of OARs as compared with concurrent boost.« less
Rossitto, Giacomo; Battistel, Michele; Barbiero, Giulio; Bisogni, Valeria; Maiolino, Giuseppe; Diego, Miotto; Seccia, Teresa M; Rossi, Gian Paolo
2018-02-01
The pulsatile secretion of adrenocortical hormones and a stress reaction occurring when starting adrenal vein sampling (AVS) can affect the selectivity and also the assessment of lateralization when sequential blood sampling is used. We therefore tested the hypothesis that a simulated sequential blood sampling could decrease the diagnostic accuracy of lateralization index for identification of aldosterone-producing adenoma (APA), as compared with bilaterally simultaneous AVS. In 138 consecutive patients who underwent subtyping of primary aldosteronism, we compared the results obtained simultaneously bilaterally when starting AVS (t-15) and 15 min after (t0), with those gained with a simulated sequential right-to-left AVS technique (R ⇒ L) created by combining hormonal values obtained at t-15 and at t0. The concordance between simultaneously obtained values at t-15 and t0, and between simultaneously obtained values and values gained with a sequential R ⇒ L technique, was also assessed. We found a marked interindividual variability of lateralization index values in the patients with bilaterally selective AVS at both time point. However, overall the lateralization index simultaneously determined at t0 provided a more accurate identification of APA than the simulated sequential lateralization indexR ⇒ L (P = 0.001). Moreover, regardless of which side was sampled first, the sequential AVS technique induced a sequence-dependent overestimation of lateralization index. While in APA patients the concordance between simultaneous AVS at t0 and t-15 and between simultaneous t0 and sequential technique was moderate-to-good (K = 0.55 and 0.66, respectively), in non-APA patients, it was poor (K = 0.12 and 0.13, respectively). Sequential AVS generates factitious between-sides gradients, which lower its diagnostic accuracy, likely because of the stress reaction arising upon starting AVS.
Privacy-Preserving Patient Similarity Learning in a Federated Environment: Development and Analysis.
Lee, Junghye; Sun, Jimeng; Wang, Fei; Wang, Shuang; Jun, Chi-Hyuck; Jiang, Xiaoqian
2018-04-13
There is an urgent need for the development of global analytic frameworks that can perform analyses in a privacy-preserving federated environment across multiple institutions without privacy leakage. A few studies on the topic of federated medical analysis have been conducted recently with the focus on several algorithms. However, none of them have solved similar patient matching, which is useful for applications such as cohort construction for cross-institution observational studies, disease surveillance, and clinical trials recruitment. The aim of this study was to present a privacy-preserving platform in a federated setting for patient similarity learning across institutions. Without sharing patient-level information, our model can find similar patients from one hospital to another. We proposed a federated patient hashing framework and developed a novel algorithm to learn context-specific hash codes to represent patients across institutions. The similarities between patients can be efficiently computed using the resulting hash codes of corresponding patients. To avoid security attack from reverse engineering on the model, we applied homomorphic encryption to patient similarity search in a federated setting. We used sequential medical events extracted from the Multiparameter Intelligent Monitoring in Intensive Care-III database to evaluate the proposed algorithm in predicting the incidence of five diseases independently. Our algorithm achieved averaged area under the curves of 0.9154 and 0.8012 with balanced and imbalanced data, respectively, in κ-nearest neighbor with κ=3. We also confirmed privacy preservation in similarity search by using homomorphic encryption. The proposed algorithm can help search similar patients across institutions effectively to support federated data analysis in a privacy-preserving manner. ©Junghye Lee, Jimeng Sun, Fei Wang, Shuang Wang, Chi-Hyuck Jun, Xiaoqian Jiang. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 13.04.2018.
Privacy-Preserving Patient Similarity Learning in a Federated Environment: Development and Analysis
Sun, Jimeng; Wang, Fei; Wang, Shuang; Jun, Chi-Hyuck; Jiang, Xiaoqian
2018-01-01
Background There is an urgent need for the development of global analytic frameworks that can perform analyses in a privacy-preserving federated environment across multiple institutions without privacy leakage. A few studies on the topic of federated medical analysis have been conducted recently with the focus on several algorithms. However, none of them have solved similar patient matching, which is useful for applications such as cohort construction for cross-institution observational studies, disease surveillance, and clinical trials recruitment. Objective The aim of this study was to present a privacy-preserving platform in a federated setting for patient similarity learning across institutions. Without sharing patient-level information, our model can find similar patients from one hospital to another. Methods We proposed a federated patient hashing framework and developed a novel algorithm to learn context-specific hash codes to represent patients across institutions. The similarities between patients can be efficiently computed using the resulting hash codes of corresponding patients. To avoid security attack from reverse engineering on the model, we applied homomorphic encryption to patient similarity search in a federated setting. Results We used sequential medical events extracted from the Multiparameter Intelligent Monitoring in Intensive Care-III database to evaluate the proposed algorithm in predicting the incidence of five diseases independently. Our algorithm achieved averaged area under the curves of 0.9154 and 0.8012 with balanced and imbalanced data, respectively, in κ-nearest neighbor with κ=3. We also confirmed privacy preservation in similarity search by using homomorphic encryption. Conclusions The proposed algorithm can help search similar patients across institutions effectively to support federated data analysis in a privacy-preserving manner. PMID:29653917
Bansal, A.; Kapoor, R.; Singh, S. K.; Kumar, N.; Oinam, A. S.; Sharma, S. C.
2012-01-01
Aims: Dosimeteric and radiobiological comparison of two radiation schedules in localized carcinoma prostate: Standard Three-Dimensional Conformal Radiotherapy (3DCRT) followed by Intensity Modulated Radiotherapy (IMRT) boost (sequential-IMRT) with Simultaneous Integrated Boost IMRT (SIB-IMRT). Material and Methods: Thirty patients were enrolled. In all, the target consisted of PTV P + SV (Prostate and seminal vesicles) and PTV LN (lymph nodes) where PTV refers to planning target volume and the critical structures included: bladder, rectum and small bowel. All patients were treated with sequential-IMRT plan, but for dosimetric comparison, SIB-IMRT plan was also created. The prescription dose to PTV P + SV was 74 Gy in both strategies but with different dose per fraction, however, the dose to PTV LN was 50 Gy delivered in 25 fractions over 5 weeks for sequential-IMRT and 54 Gy delivered in 27 fractions over 5.5 weeks for SIB-IMRT. The treatment plans were compared in terms of dose–volume histograms. Also, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) obtained with the two plans were compared. Results: The volume of rectum receiving 70 Gy or more (V > 70 Gy) was reduced to 18.23% with SIB-IMRT from 22.81% with sequential-IMRT. SIB-IMRT reduced the mean doses to both bladder and rectum by 13% and 17%, respectively, as compared to sequential-IMRT. NTCP of 0.86 ± 0.75% and 0.01 ± 0.02% for the bladder, 5.87 ± 2.58% and 4.31 ± 2.61% for the rectum and 8.83 ± 7.08% and 8.25 ± 7.98% for the bowel was seen with sequential-IMRT and SIB-IMRT plans respectively. Conclusions: For equal PTV coverage, SIB-IMRT markedly reduced doses to critical structures, therefore should be considered as the strategy for dose escalation. SIB-IMRT achieves lesser NTCP than sequential-IMRT. PMID:23204659
Yoo, Myung Hoon; Lim, Won Sub; Park, Joo Hyun; Kwon, Joong Keun; Lee, Tae-Hoon; An, Yong-Hwi; Kim, Young-Jin; Kim, Jong Yang; Lim, Hyun Woo; Park, Hong Ju
2016-01-01
Severe-to-profound sudden sensorineural hearing loss (SSNHL) has a poor prognosis. We aimed to compare the efficacy of simultaneous and sequential oral and intratympanic steroids for this condition. Fifty patients with severe-to-profound SSNHL (>70 dB HL) were included from 7 centers. The simultaneous group (27 patients) received oral and intratympanic steroid injections for 2 weeks. The sequential group (23 patients) was treated with oral steroids for 2 weeks and intratympanic steroids for the subsequent 2 weeks. Pure-tone averages (PTA) and word discrimination scores (WDS) were compared before treatment and 2 weeks and 1 and 2 months after treatment. Treatment outcomes according to the modified American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) criteria were also analyzed. The improvement in PTA and WDS at the 2-week follow-up was 23 ± 21 dB HL and 20 ± 39% in the simultaneous group and 31 ± 29 dB HL and 37 ± 42% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-week follow-up was observed in 26% of the simultaneous group and 30% of the sequential group; this was also not significant. The improvement in PTA and WDS at the 2-month follow-up was 40 ± 20 dB HL and 37 ± 35% in the simultaneous group and 41 ± 25 dB HL and 48 ± 41% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-month follow-up was observed in 33% of the simultaneous group and 35% of the sequential group; this was also not significant. Seven patients in the sequential group did not need intratympanic steroid injections for sufficient improvement after oral steroids alone. Simultaneous oral/intratympanic steroid treatment yielded a recovery similar to that produced by sequential treatment. Because the addition of intratympanic steroids can be decided upon based on the improvement after an oral steroid, the sequential regimen can be recommended to avoid unnecessary intratympanic injections. © 2017 S. Karger AG, Basel.
Ciray, Haydar Nadir; Aksoy, Turan; Goktas, Cihan; Ozturk, Bilgen; Bahceci, Mustafa
2012-09-01
To compare the dynamics of early development between embryos cultured in single and sequential media. Randomized, comparative study. Private IVF centre. A total of 446 metaphase II oocytes from 51 couples who underwent oocyte retrieval procedure for intracytoplasmic sperm injection. Forty-nine resulted in embryo transfer. Oocytes were split between single and sequential media produced by the same manufacturer and cultured in a time-lapse incubator. Morphokinetic parameters until the embryos reached the 5-cell stage (t5), utilization, clinical pregnancy and implantation rates. Embryos cultured in single media were advanced from the first mitosis cycle and reached 2- to 5-cell stages earlier. There was not any difference between the durations for cell cycle two (cc2 = t3-t2) and s2 (t4-t3). The utilization, clinical pregnancy and implantation rates did not differ between groups. The proportion of cryopreserved day 6 embryos to two pronuclei oocytes was significantly higher in sequential than in single media. Morphokinetics of embryo development vary between single and sequential culture media at least until the 5-cell stage. The overall clinical and embryological parameters remain similar regardless of the culture system.
A Bayesian sequential design with adaptive randomization for 2-sided hypothesis test.
Yu, Qingzhao; Zhu, Lin; Zhu, Han
2017-11-01
Bayesian sequential and adaptive randomization designs are gaining popularity in clinical trials thanks to their potentials to reduce the number of required participants and save resources. We propose a Bayesian sequential design with adaptive randomization rates so as to more efficiently attribute newly recruited patients to different treatment arms. In this paper, we consider 2-arm clinical trials. Patients are allocated to the 2 arms with a randomization rate to achieve minimum variance for the test statistic. Algorithms are presented to calculate the optimal randomization rate, critical values, and power for the proposed design. Sensitivity analysis is implemented to check the influence on design by changing the prior distributions. Simulation studies are applied to compare the proposed method and traditional methods in terms of power and actual sample sizes. Simulations show that, when total sample size is fixed, the proposed design can obtain greater power and/or cost smaller actual sample size than the traditional Bayesian sequential design. Finally, we apply the proposed method to a real data set and compare the results with the Bayesian sequential design without adaptive randomization in terms of sample sizes. The proposed method can further reduce required sample size. Copyright © 2017 John Wiley & Sons, Ltd.
Modifications of Saccharomyces pastorianus cell wall polysaccharides with brewing process.
Bastos, Rita; Coelho, Elisabete; Coimbra, Manuel A
2015-06-25
The cell wall polysaccharides of brewers spent yeast Saccharomyces pastorianus (BSY) and the inoculum yeast (IY) were studied in order to understand the changes induced by the brewing process. The hot water and alkali extractions performed solubilized mainly mannoproteins, more branched for BSY than those of IY. Also, (31)P solid state NMR showed that the BSY mannoproteins were 3 times more phosphorylated. By electron microscopy it was observed that the final residues of alkali sequential extraction until 4M KOH preserved the yeast three-dimensional structure. The final residues, composed mainly by glucans (92%), showed that the BSY, when compared with IY, contained higher amount of (1→4)-linked Glc (43% for BSY and 16% for IY) and lower (1→3)-linked Glc (17% for BSY and 42% for IY). The enzymatic treatment of final residue showed that both BSY and IY had (α1→4)-linked Glc and (β1→4)-linked Glc, in a 2:1 ratio, showing that S. pastorianus increases their cellulose-like linkages with the brewing process. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rareş, Andrei; Reinders, Marcel J T; Biemond, Jan
2005-10-01
In this paper, we propose a new image inpainting algorithm that relies on explicit edge information. The edge information is used both for the reconstruction of a skeleton image structure in the missing areas, as well as for guiding the interpolation that follows. The structure reconstruction part exploits different properties of the edges, such as the colors of the objects they separate, an estimate of how well one edge continues into another one, and the spatial order of the edges with respect to each other. In order to preserve both sharp and smooth edges, the areas delimited by the recovered structure are interpolated independently, and the process is guided by the direction of the nearby edges. The novelty of our approach lies primarily in exploiting explicitly the constraint enforced by the numerical interpretation of the sequential order of edges, as well as in the pixel filling method which takes into account the proximity and direction of edges. Extensive experiments are carried out in order to validate and compare the algorithm both quantitatively and qualitatively. They show the advantages of our algorithm and its readily application to real world cases.
Dobolyi, David G; Dodson, Chad S
2013-12-01
Confidence judgments for eyewitness identifications play an integral role in determining guilt during legal proceedings. Past research has shown that confidence in positive identifications is strongly associated with accuracy. Using a standard lineup recognition paradigm, we investigated accuracy using signal detection and ROC analyses, along with the tendency to choose a face with both simultaneous and sequential lineups. We replicated past findings of reduced rates of choosing with sequential as compared to simultaneous lineups, but notably found an accuracy advantage in favor of simultaneous lineups. Moreover, our analysis of the confidence-accuracy relationship revealed two key findings. First, we observed a sequential mistaken identification overconfidence effect: despite an overall reduction in false alarms, confidence for false alarms that did occur was higher with sequential lineups than with simultaneous lineups, with no differences in confidence for correct identifications. This sequential mistaken identification overconfidence effect is an expected byproduct of the use of a more conservative identification criterion with sequential than with simultaneous lineups. Second, we found a steady drop in confidence for mistaken identifications (i.e., foil identifications and false alarms) from the first to the last face in sequential lineups, whereas confidence in and accuracy of correct identifications remained relatively stable. Overall, we observed that sequential lineups are both less accurate and produce higher confidence false identifications than do simultaneous lineups. Given the increasing prominence of sequential lineups in our legal system, our data argue for increased scrutiny and possibly a wholesale reevaluation of this lineup format. PsycINFO Database Record (c) 2013 APA, all rights reserved.
von Helversen, Bettina; Mata, Rui
2012-12-01
We investigated the contribution of cognitive ability and affect to age differences in sequential decision making by asking younger and older adults to shop for items in a computerized sequential decision-making task. Older adults performed poorly compared to younger adults partly due to searching too few options. An analysis of the decision process with a formal model suggested that older adults set lower thresholds for accepting an option than younger participants. Further analyses suggested that positive affect, but not fluid abilities, was related to search in the sequential decision task. A second study that manipulated affect in younger adults supported the causal role of affect: Increased positive affect lowered the initial threshold for accepting an attractive option. In sum, our results suggest that positive affect is a key factor determining search in sequential decision making. Consequently, increased positive affect in older age may contribute to poorer sequential decisions by leading to insufficient search. 2013 APA, all rights reserved
Pihlajaniemi, Ville; Sipponen, Satu; Sipponen, Mika H; Pastinen, Ossi; Laakso, Simo
2014-02-01
In the enzymatic hydrolysis of lignocellulose materials, the recycling of the solid residue has previously been considered within the context of enzyme recycling. In this study, a steady state investigation of a solids-recycling process was made with pretreated wheat straw and compared to sequential and batch hydrolysis at constant reaction times, substrate feed and liquid and enzyme consumption. Compared to batch hydrolysis, the recycling and sequential processes showed roughly equal hydrolysis yields, while the volumetric productivity was significantly increased. In the 72h process the improvement was 90% due to an increased reaction consistency, while the solids feed was 16% of the total process constituents. The improvement resulted primarily from product removal, which was equally efficient in solids-recycling and sequential hydrolysis processes. No evidence of accumulation of enzymes beyond the accumulation of the substrate was found in recycling. A mathematical model of solids-recycling was constructed, based on a geometrical series. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Noh, S.; Tachikawa, Y.; Shiiba, M.; Kim, S.
2011-12-01
Applications of the sequential data assimilation methods have been increasing in hydrology to reduce uncertainty in the model prediction. In a distributed hydrologic model, there are many types of state variables and each variable interacts with each other based on different time scales. However, the framework to deal with the delayed response, which originates from different time scale of hydrologic processes, has not been thoroughly addressed in the hydrologic data assimilation. In this study, we propose the lagged filtering scheme to consider the lagged response of internal states in a distributed hydrologic model using two filtering schemes; particle filtering (PF) and ensemble Kalman filtering (EnKF). The EnKF is one of the widely used sub-optimal filters implementing an efficient computation with limited number of ensemble members, however, still based on Gaussian approximation. PF can be an alternative in which the propagation of all uncertainties is carried out by a suitable selection of randomly generated particles without any assumptions about the nature of the distributions involved. In case of PF, advanced particle regularization scheme is implemented together to preserve the diversity of the particle system. In case of EnKF, the ensemble square root filter (EnSRF) are implemented. Each filtering method is parallelized and implemented in the high performance computing system. A distributed hydrologic model, the water and energy transfer processes (WEP) model, is applied for the Katsura River catchment, Japan to demonstrate the applicability of proposed approaches. Forecasted results via PF and EnKF are compared and analyzed in terms of the prediction accuracy and the probabilistic adequacy. Discussions are focused on the prospects and limitations of each data assimilation method.
The composite sequential clustering technique for analysis of multispectral scanner data
NASA Technical Reports Server (NTRS)
Su, M. Y.
1972-01-01
The clustering technique consists of two parts: (1) a sequential statistical clustering which is essentially a sequential variance analysis, and (2) a generalized K-means clustering. In this composite clustering technique, the output of (1) is a set of initial clusters which are input to (2) for further improvement by an iterative scheme. This unsupervised composite technique was employed for automatic classification of two sets of remote multispectral earth resource observations. The classification accuracy by the unsupervised technique is found to be comparable to that by traditional supervised maximum likelihood classification techniques. The mathematical algorithms for the composite sequential clustering program and a detailed computer program description with job setup are given.
Specification and verification of gate-level VHDL models of synchronous and asynchronous circuits
NASA Technical Reports Server (NTRS)
Russinoff, David M.
1995-01-01
We present a mathematical definition of hardware description language (HDL) that admits a semantics-preserving translation to a subset of VHDL. Our HDL includes the basic VHDL propagation delay mechanisms and gate-level circuit descriptions. We also develop formal procedures for deriving and verifying concise behavioral specifications of combinational and sequential devices. The HDL and the specification procedures have been formally encoded in the computational logic of Boyer and Moore, which provides a LISP implementation as well as a facility for mechanical proof-checking. As an application, we design, specify, and verify a circuit that achieves asynchronous communication by means of the biphase mark protocol.
Scott, Anthony; Jeon, Sung-Hee; Joyce, Catherine M; Humphreys, John S; Kalb, Guyonne; Witt, Julia; Leahy, Anne
2011-09-05
Surveys of doctors are an important data collection method in health services research. Ways to improve response rates, minimise survey response bias and item non-response, within a given budget, have not previously been addressed in the same study. The aim of this paper is to compare the effects and costs of three different modes of survey administration in a national survey of doctors. A stratified random sample of 4.9% (2,702/54,160) of doctors undertaking clinical practice was drawn from a national directory of all doctors in Australia. Stratification was by four doctor types: general practitioners, specialists, specialists-in-training, and hospital non-specialists, and by six rural/remote categories. A three-arm parallel trial design with equal randomisation across arms was used. Doctors were randomly allocated to: online questionnaire (902); simultaneous mixed mode (a paper questionnaire and login details sent together) (900); or, sequential mixed mode (online followed by a paper questionnaire with the reminder) (900). Analysis was by intention to treat, as within each primary mode, doctors could choose either paper or online. Primary outcome measures were response rate, survey response bias, item non-response, and cost. The online mode had a response rate 12.95%, followed by the simultaneous mixed mode with 19.7%, and the sequential mixed mode with 20.7%. After adjusting for observed differences between the groups, the online mode had a 7 percentage point lower response rate compared to the simultaneous mixed mode, and a 7.7 percentage point lower response rate compared to sequential mixed mode. The difference in response rate between the sequential and simultaneous modes was not statistically significant. Both mixed modes showed evidence of response bias, whilst the characteristics of online respondents were similar to the population. However, the online mode had a higher rate of item non-response compared to both mixed modes. The total cost of the online survey was 38% lower than simultaneous mixed mode and 22% lower than sequential mixed mode. The cost of the sequential mixed mode was 14% lower than simultaneous mixed mode. Compared to the online mode, the sequential mixed mode was the most cost-effective, although exhibiting some evidence of response bias. Decisions on which survey mode to use depend on response rates, response bias, item non-response and costs. The sequential mixed mode appears to be the most cost-effective mode of survey administration for surveys of the population of doctors, if one is prepared to accept a degree of response bias. Online surveys are not yet suitable to be used exclusively for surveys of the doctor population.
2011-01-01
Background Surveys of doctors are an important data collection method in health services research. Ways to improve response rates, minimise survey response bias and item non-response, within a given budget, have not previously been addressed in the same study. The aim of this paper is to compare the effects and costs of three different modes of survey administration in a national survey of doctors. Methods A stratified random sample of 4.9% (2,702/54,160) of doctors undertaking clinical practice was drawn from a national directory of all doctors in Australia. Stratification was by four doctor types: general practitioners, specialists, specialists-in-training, and hospital non-specialists, and by six rural/remote categories. A three-arm parallel trial design with equal randomisation across arms was used. Doctors were randomly allocated to: online questionnaire (902); simultaneous mixed mode (a paper questionnaire and login details sent together) (900); or, sequential mixed mode (online followed by a paper questionnaire with the reminder) (900). Analysis was by intention to treat, as within each primary mode, doctors could choose either paper or online. Primary outcome measures were response rate, survey response bias, item non-response, and cost. Results The online mode had a response rate 12.95%, followed by the simultaneous mixed mode with 19.7%, and the sequential mixed mode with 20.7%. After adjusting for observed differences between the groups, the online mode had a 7 percentage point lower response rate compared to the simultaneous mixed mode, and a 7.7 percentage point lower response rate compared to sequential mixed mode. The difference in response rate between the sequential and simultaneous modes was not statistically significant. Both mixed modes showed evidence of response bias, whilst the characteristics of online respondents were similar to the population. However, the online mode had a higher rate of item non-response compared to both mixed modes. The total cost of the online survey was 38% lower than simultaneous mixed mode and 22% lower than sequential mixed mode. The cost of the sequential mixed mode was 14% lower than simultaneous mixed mode. Compared to the online mode, the sequential mixed mode was the most cost-effective, although exhibiting some evidence of response bias. Conclusions Decisions on which survey mode to use depend on response rates, response bias, item non-response and costs. The sequential mixed mode appears to be the most cost-effective mode of survey administration for surveys of the population of doctors, if one is prepared to accept a degree of response bias. Online surveys are not yet suitable to be used exclusively for surveys of the doctor population. PMID:21888678
Organic carbon characteristics in density fractions of soils with contrasting mineralogies
NASA Astrophysics Data System (ADS)
Yeasmin, Sabina; Singh, Balwant; Johnston, Cliff T.; Sparks, Donald L.
2017-12-01
This study was aimed to evaluate the role of minerals in the preservation of organic carbon (OC) in different soil types. Sequential density fractionation was done to isolate particulate organic matter (POM, <1.8 g cm-3) and mineral associated OM (MOM: 1.8-2.2, 2.2-2.6 and >2.6 g cm-3) from four soils, i.e., a Ferralsol, a Luvisol, a Vertisol and a Solonetz. Organic matter (OM) in the density fractions was characterised using diffuse reflectance Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and mass spectroscopy in the original states (i.e., without any chemical pre-treatment), and after 6% sodium hypochlorite (NaOCl) and 10% hydrofluoric acid (HF) treatments. The NaOCl oxidation resistant fraction was considered as a relatively stable pool of OC and the HF soluble fraction was presumed as the mineral bound OC. Phyllosilicate-dominated soils, i.e., Vertisol, Luvisol and Solonetz, contained a greater proportion of POM than Fe and Al oxide-dominated Ferralsol. Wider C:N ratio and lower δ13C and δ15N in POM suggest the dominance of labile OC in this fraction and this was also supported by a greater proportion of NaOCl oxidised OC in the same fraction that was enriched with aliphatic C. The sequential density fractionation method effectively isolated OM into three distinct groups in the soils: (i) OM associated with Fe and Al oxides (>1.8 g cm-3 in the Ferralsol); (ii) OM associated with phyllosilicates (1.8-2.6 g cm-3) and (iii) OM associated with quartz and feldspar (>2.6 g cm-3) in the other three soils. Greater oxidation resistance, and more dissolution of OC during the HF treatment in the Fe and Al oxides dominated fractions suggest a greater potential of these minerals to protect OC from oxidative degradation as compared to the phyllosilicates, and quartz and feldspar matrices. OM associated with Fe and Al oxides was predominantly aromatic and carboxylate C. Decreased C:N ratio in the NaOCl oxidation resistant OM and HF soluble OM of phyllosilicates, and quartz and feldspars dominant fractions compared to their untreated fractions indicate a preferred retention of N rich organic compounds by these minerals. OM associated with phyllosilicates was enriched with protonated amide N and aromatic C. Quartz and feldspars associated OM comprised of N containing organic compounds and polysaccharides, although we don't expect any role of these minerals in their preservation. Our results imply that the abundance and surface properties of minerals in the soil largely control the dynamics of OC and subsequently protect OC from microbial cycling.
Saadeh, Charles K; Rosero, Eric B; Joshi, Girish P; Ozayar, Esra; Mau, Ted
2017-12-01
To determine the extent to which a sequential anesthetic technique 1) shortens time under sedation for thyroplasty with arytenoid adduction (TP-AA), 2) affects the total operative time, and 3) changes the voice outcome compared to TP-AA performed entirely under sedation/analgesia. Case-control study. A new sequential anesthetic technique of performing most of the TP-AA surgery under general anesthesia (GA), followed by transition to sedation/analgesia (SA) for voice assessment, was developed to achieve smooth emergence from GA. Twenty-five TP-AA cases performed with the sequential GA-SA technique were compared with 25 TP-AA controls performed completely under sedation/analgesia. The primary outcome measure was the time under sedation. Voice improvement, as assessed by Consensus Auditory-Perceptual Evaluation of Voice, and total operative time were secondary outcome measures. With the conventional all-SA anesthetic, the duration of SA was 209 ± 26.3 minutes. With the sequential GA-SA technique, the duration of SA was 79.0 ± 18.9 minutes, a 62.3% reduction (P < 0.0001). There was no significant difference in the total operative time (209.5 vs. 200.9 minutes; P = 0.42) or in voice outcome. This sequential anesthetic technique has been easily adopted by multiple anesthesiologists and nurse anesthetists at our institution. TP-AA is effectively performed under sequential GA-SA technique with a significant reduction in the duration of time under sedation. This allows the surgeon to perform the technically more challenging part of the surgery under GA, without having to contend with variability in patient tolerance for laryngeal manipulation under sedation. 3b. Laryngoscope, 127:2813-2817, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Outcomes of simultaneous resections for patients with synchronous colorectal liver metastases.
Slesser, A A P; Chand, M; Goldin, R; Brown, G; Tekkis, P P; Mudan, S
2013-12-01
The aim of this study was to determine the outcomes associated with simultaneous resections compared to patients undergoing sequential resections for synchronous colorectal liver metastases. Consecutive patients undergoing hepatic resections between 2000 and 2012 for synchronous colorectal liver metastases were identified from a prospectively maintained database. Of the 112 hepatic resections that were performed, 36 were simultaneous resections and 76 were sequential resections. There was no difference in disease severity: number of metastases (P 0.228), metastatic size (P 0.58), the primary tumour nodal status (P 0.283), CEA (P 0.387) or the presence of extra-hepatic metastases (P 1.0). Major hepatic resections were performed in 23 (64%) and 60 (79%) of patients in the simultaneous and sequential groups respectively (P 0.089). Intra-operatively no differences were found in blood loss (P 1.0), duration of surgery (P 0.284) or number of adverse events (P 1.0). There were no differences in post-operative complications (P 0.161) or post-operative mortality (P 0.241). The length of hospital stay was 14 (95% CI 12.0-18.0) and 18.5 (95% CI 16.0-23.0) days in the simultaneous and sequential groups respectively (P 0.03). The 3-year overall survival was 75% and 64% in the simultaneous and sequential groups respectively (P 0.379). The 3-year hepatic recurrence free survival was 61% and 46% in the simultaneous and sequential groups respectively (P 0.254). Simultaneous resections result in similar short-term and long-term outcomes as patients receiving sequential resections with comparable metastatic disease and are associated with a significant reduction in the length of stay. Copyright © 2013 Elsevier Ltd. All rights reserved.
Chadha, Neil K; Papsin, Blake C; Jiwani, Salima; Gordon, Karen A
2011-09-01
To measure speech detection in noise performance for children with bilateral cochlear implants (BiCI), to compare performance in children with simultaneous implant versus those with sequential implant, and to compare performance to normal-hearing children. Prospective cohort study. Tertiary academic pediatric center. Children with early-onset bilateral deafness and 2-year BiCI experience, comprising the "sequential" group (>2 yr interimplantation delay, n = 12) and "simultaneous group" (no interimplantation delay, n = 10) and normal-hearing controls (n = 8). Thresholds to speech detection (at 0-degree azimuth) were measured with noise at 0-degree azimuth or ± 90-degree azimuth. Spatial unmasking (SU) as the noise condition changed from 0-degree azimuth to ± 90-degree azimuth and binaural summation advantage (BSA) of 2 over 1 CI. Speech detection in noise was significantly poorer than controls for both BiCI groups (p < 0.0001). However, the SU in the simultaneous group approached levels found in normal controls (7.2 ± 0.6 versus 8.6 ± 0.6 dB, p > 0.05) and was significantly better than that in the sequential group (3.9 ± 0.4 dB, p < 0.05). Spatial unmasking was unaffected by the side of noise presentation in the simultaneous group but, in the sequential group, was significantly better when noise was moved to the second rather than the first implanted ear (4.8 ± 0.5 versus 3.0 ± 0.4 dB, p < 0.05). This was consistent with a larger BSA from the sequential group's second rather than first CI. Children with simultaneously implanted BiCI demonstrated an advantage over children with sequential implant by using spatial cues to improve speech detection in noise.
Chang, Young-Soo; Hong, Sung Hwa; Kim, Eun Yeon; Choi, Ji Eun; Chung, Won-Ho; Cho, Yang-Sun; Moon, Il Joon
2018-05-18
Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1+HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1+CI2). The good Performance Group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1+CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Compared to the CI1+HA, CI1+CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio=4.38, 95% confidence interval - 95%=1.07-17.93, p=0.04). The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential cochlear implant. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Yu, Yang; Zhang, Fan; Gao, Ming-Xin; Li, Hai-Tao; Li, Jing-Xing; Song, Wei; Huang, Xin-Sheng; Gu, Cheng-Xiong
2013-01-01
OBJECTIVES Intraoperative transit time flow measurement (TTFM) is widely used to assess anastomotic quality in coronary artery bypass grafting (CABG). However, in sequential vein grafting, the flow characteristics collected by the conventional TTFM method are usually associated with total graft flow and might not accurately indicate the quality of every distal anastomosis in a sequential graft. The purpose of our study was to examine a new TTFM method that could assess the quality of each distal anastomosis in a sequential graft more reliably than the conventional TTFM approach. METHODS Two TTFM methods were tested in 84 patients who underwent sequential saphenous off-pump CABG in Beijing An Zhen Hospital between April and August 2012. In the conventional TTFM method, normal blood flow in the sequential graft was maintained during the measurement, and the flow probe was placed a few centimetres above the anastomosis to be evaluated. In the new method, blood flow in the sequential graft was temporarily reduced during the measurement by placing an atraumatic bulldog clamp at the graft a few centimetres distal to the anastomosis to be evaluated, while the position of the flow probe remained the same as in the conventional method. This new TTFM method was named the flow reduction TTFM. Graft flow parameters measured by both methods were compared. RESULTS Compared with the conventional TTFM, the flow reduction TTFM resulted in significantly lower mean graft blood flow (P < 0.05); in contrast, yielded significantly higher pulsatility index (P < 0.05). Diastolic filling was not significantly different between the two methods and was >50% in both cases. Interestingly, the flow reduction TTFM identified two defective middle distal anastomoses that the conventional TTFM failed to detect. Graft flows near the defective distal anastomoses were improved substantially after revision. CONCLUSIONS In this study, we found that temporary reduction of graft flow during TTFM seemed to enhance the sensitivity of TTFM to less-than-critical anastomotic defects in a sequential graft and to improve the overall accuracy of the intraoperative assessment of anastomotic quality in sequential vein grafting. PMID:24000314
Simultaneous versus sequential penetrating keratoplasty and cataract surgery.
Hayashi, Ken; Hayashi, Hideyuki
2006-10-01
To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.
Analyses of group sequential clinical trials.
Koepcke, W
1989-12-01
In the first part of this article the methodology of group sequential plans is reviewed. After introducing the basic definition of such plans the main properties are shown. At the end of this section three different plans (Pocock, O'Brien-Fleming, Koepcke) are compared. In the second part of the article some unresolved issues and recent developments in the application of group sequential methods to long-term controlled clinical trials are discussed. These include deviation from the assumptions, life table methods, multiple-arm clinical trials, multiple outcome measures, and confidence intervals.
Increased Automaticity and Altered Temporal Preparation Following Sleep Deprivation
Kong, Danyang; Asplund, Christopher L.; Ling, Aiqing; Chee, Michael W.L.
2015-01-01
Study Objectives: Temporal expectation enables us to focus limited processing resources, thereby optimizing perceptual and motor processing for critical upcoming events. We investigated the effects of total sleep deprivation (TSD) on temporal expectation by evaluating the foreperiod and sequential effects during a psychomotor vigilance task (PVT). We also examined how these two measures were modulated by vulnerability to TSD. Design: Three 10-min visual PVT sessions using uniformly distributed foreperiods were conducted in the wake-maintenance zone the evening before sleep deprivation (ESD) and three more in the morning following approximately 22 h of TSD. TSD vulnerable and nonvulnerable groups were determined by a tertile split of participants based on the change in the number of behavioral lapses recorded during ESD and TSD. A subset of participants performed six additional 10-min modified auditory PVTs with exponentially distributed foreperiods during rested wakefulness (RW) and TSD to test the effect of temporal distribution on foreperiod and sequential effects. Setting: Sleep laboratory. Participants: There were 172 young healthy participants (90 males) with regular sleep patterns. Nineteen of these participants performed the modified auditory PVT. Measurements and Results: Despite behavioral lapses and slower response times, sleep deprived participants could still perceive the conditional probability of temporal events and modify their level of preparation accordingly. Both foreperiod and sequential effects were magnified following sleep deprivation in vulnerable individuals. Only the foreperiod effect increased in nonvulnerable individuals. Conclusions: The preservation of foreperiod and sequential effects suggests that implicit time perception and temporal preparedness are intact during total sleep deprivation. Individuals appear to reallocate their depleted preparatory resources to more probable event timings in ongoing trials, whereas vulnerable participants also rely more on automatic processes. Citation: Kong D, Asplund CL, Ling A, Chee MWL. Increased automaticity and altered temporal preparation following sleep deprivation. SLEEP 2015;38(8):1219–1227. PMID:25845689
Spatial-Sequential and Spatial-Simultaneous Working Memory in Individuals with Williams Syndrome
ERIC Educational Resources Information Center
Lanfranchi, Silvia; De Mori, Letizia; Mammarella, Irene C.; Carretti, Barbara; Vianello, Renzo
2015-01-01
The aim of the present study was to compare visuospatial working memory performance in 18 individuals with Williams syndrome (WS) and 18 typically developing (TD) children matched for nonverbal mental age. Two aspects were considered: task presentation format (i.e., spatial-sequential or spatial-simultaneous), and level of attentional control…
The Sequential Probability Ratio Test and Binary Item Response Models
ERIC Educational Resources Information Center
Nydick, Steven W.
2014-01-01
The sequential probability ratio test (SPRT) is a common method for terminating item response theory (IRT)-based adaptive classification tests. To decide whether a classification test should stop, the SPRT compares a simple log-likelihood ratio, based on the classification bound separating two categories, to prespecified critical values. As has…
Monte Carlo Simulation of Sudden Death Bearing Testing
NASA Technical Reports Server (NTRS)
Vlcek, Brian L.; Hendricks, Robert C.; Zaretsky, Erwin V.
2003-01-01
Monte Carlo simulations combined with sudden death testing were used to compare resultant bearing lives to the calculated hearing life and the cumulative test time and calendar time relative to sequential and censored sequential testing. A total of 30 960 virtual 50-mm bore deep-groove ball bearings were evaluated in 33 different sudden death test configurations comprising 36, 72, and 144 bearings each. Variations in both life and Weibull slope were a function of the number of bearings failed independent of the test method used and not the total number of bearings tested. Variation in L10 life as a function of number of bearings failed were similar to variations in lift obtained from sequentially failed real bearings and from Monte Carlo (virtual) testing of entire populations. Reductions up to 40 percent in bearing test time and calendar time can be achieved by testing to failure or the L(sub 50) life and terminating all testing when the last of the predetermined bearing failures has occurred. Sudden death testing is not a more efficient method to reduce bearing test time or calendar time when compared to censored sequential testing.
Devaluation and sequential decisions: linking goal-directed and model-based behavior
Friedel, Eva; Koch, Stefan P.; Wendt, Jean; Heinz, Andreas; Deserno, Lorenz; Schlagenhauf, Florian
2014-01-01
In experimental psychology different experiments have been developed to assess goal–directed as compared to habitual control over instrumental decisions. Similar to animal studies selective devaluation procedures have been used. More recently sequential decision-making tasks have been designed to assess the degree of goal-directed vs. habitual choice behavior in terms of an influential computational theory of model-based compared to model-free behavioral control. As recently suggested, different measurements are thought to reflect the same construct. Yet, there has been no attempt to directly assess the construct validity of these different measurements. In the present study, we used a devaluation paradigm and a sequential decision-making task to address this question of construct validity in a sample of 18 healthy male human participants. Correlational analysis revealed a positive association between model-based choices during sequential decisions and goal-directed behavior after devaluation suggesting a single framework underlying both operationalizations and speaking in favor of construct validity of both measurement approaches. Up to now, this has been merely assumed but never been directly tested in humans. PMID:25136310
Rosenkrantz, Andrew B; Balar, Arjun V; Huang, William C; Jackson, Kimberly; Friedman, Kent P
2015-08-01
The aim of this study was to compare coregistration of the bladder wall, bladder masses, and pelvic lymph nodes between sequential and simultaneous PET and MRI acquisitions obtained during hybrid (18)F-FDG PET/MRI performed using a diuresis protocol in bladder cancer patients. Six bladder cancer patients underwent (18)F-FDG hybrid PET/MRI, including IV Lasix administration and oral hydration, before imaging to achieve bladder clearance. Axial T2-weighted imaging (T2WI) was obtained approximately 40 minutes before PET ("sequential") and concurrently with PET ("simultaneous"). Three-dimensional spatial coordinates of the bladder wall, bladder masses, and pelvic lymph nodes were recorded for PET and T2WI. Distances between these locations on PET and T2WI sequences were computed and used to compare in-plane (x-y plane) and through-plane (z-axis) misregistration relative to PET between T2WI acquisitions. The bladder increased in volume between T2WI acquisitions (sequential, 176 [139] mL; simultaneous, 255 [146] mL). Four patients exhibited a bladder mass, all with increased activity (SUV, 9.5-38.4). Seven pelvic lymph nodes in 4 patients showed increased activity (SUV, 2.2-9.9). The bladder wall exhibited substantially less misregistration relative to PET for simultaneous, compared with sequential, acquisitions in in-plane (2.8 [3.1] mm vs 7.4 [9.1] mm) and through-plane (1.7 [2.2] mm vs 5.7 [9.6] mm) dimensions. Bladder masses exhibited slightly decreased misregistration for simultaneous, compared with sequential, acquisitions in in-plane (2.2 [1.4] mm vs 2.6 [1.9] mm) and through-plane (0.0 [0.0] mm vs 0.3 [0.8] mm) dimensions. FDG-avid lymph nodes exhibited slightly decreased in-plane misregistration (1.1 [0.8] mm vs 2.5 [0.6] mm), although identical through-plane misregistration (4.0 [1.9] mm vs 4.0 [2.8] mm). Using hybrid PET/MRI, simultaneous imaging substantially improved bladder wall coregistration and slightly improved coregistration of bladder masses and pelvic lymph nodes.
Saxena, Saurabh; Stanek, Jan; Cevec, Mirko; Plavec, Janez; Koźmiński, Wiktor
2014-11-01
A through bond, C4'/H4' selective, "out and stay" type 4D HC(P)CH experiment is introduced which provides sequential connectivity via H4'(i)-C4'(i)-C4'(i-1)-H4'(i-1) correlations. The (31)P dimension (used in the conventional 3D HCP experiment) is replaced with evolution of better dispersed C4' dimension. The experiment fully utilizes (13)C-labeling of RNA by inclusion of two C4' evolution periods. An additional evolution of H4' is included to further enhance peak resolution. Band selective (13)C inversion pulses are used to achieve selectivity and prevent signal dephasing due to the of C4'-C3' and C4'-C5' homonuclear couplings. For reasonable resolution, non-uniform sampling is employed in all indirect dimensions. To reduce sensitivity losses, multiple quantum coherences are preserved during shared-time evolution and coherence transfer delays. In the experiment the intra-nucleotide peaks are suppressed whereas inter-nucleotide peaks are enhanced to reduce the ambiguities. The performance of the experiment is verified on a fully (13)C, (15)N-labeled 34-nt hairpin RNA comprising typical structure elements.
The possibility of application of spiral brain computed tomography to traumatic brain injury.
Lim, Daesung; Lee, Soo Hoon; Kim, Dong Hoon; Choi, Dae Seub; Hong, Hoon Pyo; Kang, Changwoo; Jeong, Jin Hee; Kim, Seong Chun; Kang, Tae-Sin
2014-09-01
The spiral computed tomography (CT) with the advantage of low radiation dose, shorter test time required, and its multidimensional reconstruction is accepted as an essential diagnostic method for evaluating the degree of injury in severe trauma patients and establishment of therapeutic plans. However, conventional sequential CT is preferred for the evaluation of traumatic brain injury (TBI) over spiral CT due to image noise and artifact. We aimed to compare the diagnostic power of spiral facial CT for TBI to that of conventional sequential brain CT. We evaluated retrospectively the images of 315 traumatized patients who underwent both brain CT and facial CT simultaneously. The hemorrhagic traumatic brain injuries such as epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, and contusional hemorrhage were evaluated in both images. Statistics were performed using Cohen's κ to compare the agreement between 2 imaging modalities and sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT to conventional sequential brain CT. Almost perfect agreement was noted regarding hemorrhagic traumatic brain injuries between spiral facial CT and conventional sequential brain CT (Cohen's κ coefficient, 0.912). To conventional sequential brain CT, sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT were 92.2%, 98.1%, 95.9%, and 96.3%, respectively. In TBI, the diagnostic power of spiral facial CT was equal to that of conventional sequential brain CT. Therefore, expanded spiral facial CT covering whole frontal lobe can be applied to evaluate TBI in the future. Copyright © 2014 Elsevier Inc. All rights reserved.
Hinault, Thomas; Lemaire, Patrick; Phillips, Natalie
2016-01-01
This study investigated age-related differences in electrophysiological signatures of sequential modulations of poorer strategy effects. Sequential modulations of poorer strategy effects refer to decreased poorer strategy effects (i.e., poorer performance when the cued strategy is not the best) on current problem following poorer strategy problems compared to after better strategy problems. Analyses on electrophysiological (EEG) data revealed important age-related changes in time, frequency, and coherence of brain activities underlying sequential modulations of poorer strategy effects. More specifically, sequential modulations of poorer strategy effects were associated with earlier and later time windows (i.e., between 200- and 550 ms and between 850- and 1250 ms). Event-related potentials (ERPs) also revealed an earlier onset in older adults, together with more anterior and less lateralized activations. Furthermore, sequential modulations of poorer strategy effects were associated with theta and alpha frequencies in young adults while these modulations were found in delta frequency and theta inter-hemispheric coherence in older adults, consistent with qualitatively distinct patterns of brain activity. These findings have important implications to further our understanding of age-related differences and similarities in sequential modulations of cognitive control processes during arithmetic strategy execution. Copyright © 2015 Elsevier B.V. All rights reserved.
The effects of sequential attention shifts within visual working memory.
Li, Qi; Saiki, Jun
2014-01-01
Previous studies have shown conflicting data as to whether it is possible to sequentially shift spatial attention among visual working memory (VWM) representations. The present study investigated this issue by asynchronously presenting attentional cues during the retention interval of a change detection task. In particular, we focused on two types of sequential attention shifts: (1) orienting attention to one location, and then withdrawing attention from it, and (2) switching the focus of attention from one location to another. In Experiment 1, a withdrawal cue was presented after a spatial retro-cue to measure the effect of withdrawing attention. The withdrawal cue significantly reduced the cost of invalid spatial cues, but surprisingly, did not attenuate the benefit of valid spatial cues. This indicates that the withdrawal cue only triggered the activation of facilitative components but not inhibitory components of attention. In Experiment 2, two spatial retro-cues were presented successively to examine the effect of switching the focus of attention. We observed equivalent benefits of the first and second spatial cues, suggesting that participants were able to reorient attention from one location to another within VWM, and the reallocation of attention did not attenuate memory at the first-cued location. In Experiment 3, we found that reducing the validity of the preceding spatial cue did lead to a significant reduction in its benefit. However, performance was still better at first-cued locations than at uncued and neutral locations, indicating that the first cue benefit might have been preserved both partially under automatic control and partially under voluntary control. Our findings revealed new properties of dynamic attentional control in VWM maintenance.
Corrected Mean-Field Model for Random Sequential Adsorption on Random Geometric Graphs
NASA Astrophysics Data System (ADS)
Dhara, Souvik; van Leeuwaarden, Johan S. H.; Mukherjee, Debankur
2018-03-01
A notorious problem in mathematics and physics is to create a solvable model for random sequential adsorption of non-overlapping congruent spheres in the d-dimensional Euclidean space with d≥ 2 . Spheres arrive sequentially at uniformly chosen locations in space and are accepted only when there is no overlap with previously deposited spheres. Due to spatial correlations, characterizing the fraction of accepted spheres remains largely intractable. We study this fraction by taking a novel approach that compares random sequential adsorption in Euclidean space to the nearest-neighbor blocking on a sequence of clustered random graphs. This random network model can be thought of as a corrected mean-field model for the interaction graph between the attempted spheres. Using functional limit theorems, we characterize the fraction of accepted spheres and its fluctuations.
A basal dinosaur from the dawn of the dinosaur era in southwestern Pangaea.
Martinez, Ricardo N; Sereno, Paul C; Alcober, Oscar A; Colombi, Carina E; Renne, Paul R; Montañez, Isabel P; Currie, Brian S
2011-01-14
Upper Triassic rocks in northwestern Argentina preserve the most complete record of dinosaurs before their rise to dominance in the Early Jurassic. Here, we describe a previously unidentified basal theropod, reassess its contemporary Eoraptor as a basal sauropodomorph, divide the faunal record of the Ischigualasto Formation with biozones, and bracket the formation with (40)Ar/(39)Ar ages. Some 230 million years ago in the Late Triassic (mid Carnian), the earliest dinosaurs were the dominant terrestrial carnivores and small herbivores in southwestern Pangaea. The extinction of nondinosaurian herbivores is sequential and is not linked to an increase in dinosaurian diversity, which weakens the predominant scenario for dinosaurian ascendancy as opportunistic replacement.
Directed evolution of an extremely stable fluorescent protein.
Kiss, Csaba; Temirov, Jamshid; Chasteen, Leslie; Waldo, Geoffrey S; Bradbury, Andrew R M
2009-05-01
In this paper we describe the evolution of eCGP123, an extremely stable green fluorescent protein based on a previously described fluorescent protein created by consensus engineering (CGP: consensus green protein). eCGP123 could not be denatured by a standard thermal melt, preserved almost full fluorescence after overnight incubation at 80 degrees C and possessed a free energy of denaturation of 12.4 kcal/mol. It was created from CGP by a recursive process involving the sequential introduction of three destabilizing heterologous inserts, evolution to overcome the destabilization and finally 'removal' of the destabilizing insert by gene synthesis. We believe that this approach may be generally applicable to the stabilization of other proteins.
Behavioral consequences of disasters: a five-stage model of population behavior.
Rudenstine, Sasha; Galea, Sandro
2014-12-01
We propose a model of population behavior in the aftermath of disasters. We conducted a qualitative analysis of an empirical dataset of 339 disasters throughout the world spanning from 1950 to 2005. We developed a model of population behavior that is based on 2 fundamental assumptions: (i) behavior is predictable and (ii) population behavior will progress sequentially through 5 stages from the moment the hazard begins until is complete. Understanding the progression of population behavior during a disaster can improve the efficiency and appropriateness of institutional efforts aimed at population preservation after large-scale traumatic events. Additionally, the opportunity for population-level intervention in the aftermath of such events will improve population health.
Ruggeri, Marco; Uhlhorn, Stephen R.; De Freitas, Carolina; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie
2012-01-01
Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time. PMID:22808424
Ruggeri, Marco; Uhlhorn, Stephen R; De Freitas, Carolina; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie
2012-07-01
An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time.
Comparison of Sequential Drug Release in Vitro and in Vivo
Sundararaj, Sharath C.; Al-Sabbagh, Mohanad; Rabek, Cheryl L.; Dziubla, Thomas D.; Thomas, Mark V.; Puleo, David A.
2015-01-01
Development of drug delivery devices typically involves characterizing in vitro release performance with the inherent assumption that this will closely approximate in vivo performance. Yet, as delivery devices become more complex, for instance with a sequential drug release pattern, it is important to confirm that in vivo properties correlate with the expected “programming” achieved in vitro. In this work, a systematic comparison between in vitro and in vivo biomaterial erosion and sequential release was performed for a multilayered association polymer system comprising cellulose acetate phthalate and Pluronic F-127. After assessing the materials during incubation in phosphate-buffered saline, devices were implanted supracalvarially in rats. Devices with two different doses and with different erosion rates were harvested at increasing times post-implantation, and the in vivo thickness loss, mass loss, and the drug release profiles were compared with their in vitro counterparts. The sequential release of four different drugs observed in vitro was successfully translated to in vivo conditions. Results suggest, however, that the total erosion time of the devices was longer and release rates of the four drugs were different, with drugs initially released more quickly and then more slowly in vivo. Whereas many comparative studies of in vitro and in vivo drug release from biodegradable polymers involved a single drug, the present research demonstrated that sequential release of four drugs can be maintained following implantation. PMID:26111338
Grover, Elise; Hossain, Mohammed Kamal; Uddin, Saker; Venkatesh, Mohini; Ram, Pavani K; Dreibelbis, Robert
2018-01-01
To determine the impact of environmental nudges on handwashing behaviours among primary school children as compared to a high-intensity hygiene education intervention. In a cluster-randomised trial (CRT), we compared the rates of handwashing with soap (HWWS) after a toileting event among primary school students in rural Bangladesh. Eligible schools (government run, on-site sanitation and water, no hygiene interventions in last year, fewer than 450 students) were identified, and 20 schools were randomly selected and allocated without blinding to one of four interventions, five schools per group: simultaneous handwashing infrastructure and nudge construction, sequential infrastructure then nudge construction, simultaneous infrastructure and high-intensity hygiene education (HE) and sequential handwashing infrastructure and HE. The primary outcome, incidence of HWWS after a toileting event, was compared between the intervention groups at different data collection points with robust-Poisson regression analysis with generalised estimating equations, adjusting for school-level clustering of outcomes. The nudge intervention and the HE intervention were found to be equally effective at sustained impact over 5 months post-intervention (adjusted IRR 0.81, 95% CI 0.61-1.09). When comparing intervention delivery timing, the simultaneous delivery of the HE intervention significantly outperformed the sequential HE delivery (adjusted IRR 1.58 CI 1.20-2.08), whereas no significant difference was observed between sequential and simultaneous nudge intervention delivery (adjusted IRR 0.75, 95% CI 0.48-1.17). Our trial demonstrates sustained improved handwashing behaviour 5 months after the nudge intervention. The nudge intervention's comparable performance to a high-intensity hygiene education intervention is encouraging. © 2017 John Wiley & Sons Ltd.
Classical and sequential limit analysis revisited
NASA Astrophysics Data System (ADS)
Leblond, Jean-Baptiste; Kondo, Djimédo; Morin, Léo; Remmal, Almahdi
2018-04-01
Classical limit analysis applies to ideal plastic materials, and within a linearized geometrical framework implying small displacements and strains. Sequential limit analysis was proposed as a heuristic extension to materials exhibiting strain hardening, and within a fully general geometrical framework involving large displacements and strains. The purpose of this paper is to study and clearly state the precise conditions permitting such an extension. This is done by comparing the evolution equations of the full elastic-plastic problem, the equations of classical limit analysis, and those of sequential limit analysis. The main conclusion is that, whereas classical limit analysis applies to materials exhibiting elasticity - in the absence of hardening and within a linearized geometrical framework -, sequential limit analysis, to be applicable, strictly prohibits the presence of elasticity - although it tolerates strain hardening and large displacements and strains. For a given mechanical situation, the relevance of sequential limit analysis therefore essentially depends upon the importance of the elastic-plastic coupling in the specific case considered.
ERIC Educational Resources Information Center
Marinis, Theodoros; Saddy, Douglas
2013-01-01
Twenty-five monolingual (L1) children with specific language impairment (SLI), 32 sequential bilingual (L2) children, and 29 L1 controls completed the Test of Active & Passive Sentences-Revised (van der Lely 1996) and the Self-Paced Listening Task with Picture Verification for actives and passives (Marinis 2007). These revealed important…
Examining Age-Related Movement Representations for Sequential (Fine-Motor) Finger Movements
ERIC Educational Resources Information Center
Gabbard, Carl; Cacola, Priscila; Bobbio, Tatiana
2011-01-01
Theory suggests that imagined and executed movement planning relies on internal models for action. Using a chronometry paradigm to compare the movement duration of imagined and executed movements, we tested children aged 7-11 years and adults on their ability to perform sequential finger movements. Underscoring this tactic was our desire to gain a…
ERIC Educational Resources Information Center
Spring, Bonnie; Pagoto, Sherry; Pingitore, Regina; Doran, Neal; Schneider, Kristin; Hedeker, Don
2004-01-01
The authors compared simultaneous versus sequential approaches to multiple health behavior change in diet, exercise, and cigarette smoking. Female regular smokers (N = 315) randomized to 3 conditions received 16 weeks of behavioral smoking treatment, quit smoking at Week 5, and were followed for 9 months after quit date. Weight management was…
Jacobs, Ian E.; Aasen, Erik W.; Oliveira, Julia L.; ...
2016-03-23
Doping polymeric semiconductors often drastically reduces the solubility of the polymer, leading to difficulties in processing doped films. Here, we compare optical, electrical, and morphological properties of P3HT films doped with F4TCNQ, both from mixed solutions and using sequential solution processing with orthogonal solvents. We demonstrate that sequential doping occurs rapidly (<1 s), and that the film doping level can be precisely controlled by varying the concentration of the doping solution. Furthermore, the choice of sequential doping solvent controls whether dopant anions are included or excluded from polymer crystallites. Atomic force microscopy (AFM) reveals that sequential doping produces significantly moremore » uniform films on the nanoscale than the mixed-solution method. In addition, we show that mixed-solution doping induces the formation of aggregates even at low doping levels, resulting in drastic changes to film morphology. Sequentially coated films show 3–15 times higher conductivities at a given doping level than solution-doped films, with sequentially doped films processed to exclude dopant anions from polymer crystallites showing the highest conductivities. In conclusion, we propose a mechanism for doping induced aggregation in which the shift of the polymer HOMO level upon aggregation couples ionization and solvation energies. To show that the methodology is widely applicable, we demonstrate that several different polymer:dopant systems can be prepared by sequential doping.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Ian E.; Aasen, Erik W.; Oliveira, Julia L.
Doping polymeric semiconductors often drastically reduces the solubility of the polymer, leading to difficulties in processing doped films. Here, we compare optical, electrical, and morphological properties of P3HT films doped with F4TCNQ, both from mixed solutions and using sequential solution processing with orthogonal solvents. We demonstrate that sequential doping occurs rapidly (<1 s), and that the film doping level can be precisely controlled by varying the concentration of the doping solution. Furthermore, the choice of sequential doping solvent controls whether dopant anions are included or excluded from polymer crystallites. Atomic force microscopy (AFM) reveals that sequential doping produces significantly moremore » uniform films on the nanoscale than the mixed-solution method. In addition, we show that mixed-solution doping induces the formation of aggregates even at low doping levels, resulting in drastic changes to film morphology. Sequentially coated films show 3–15 times higher conductivities at a given doping level than solution-doped films, with sequentially doped films processed to exclude dopant anions from polymer crystallites showing the highest conductivities. In conclusion, we propose a mechanism for doping induced aggregation in which the shift of the polymer HOMO level upon aggregation couples ionization and solvation energies. To show that the methodology is widely applicable, we demonstrate that several different polymer:dopant systems can be prepared by sequential doping.« less
Kim, You Keun; Ahn, Jong Hyun; Yoo, Jae Doo
2017-12-01
This study aimed to compare stability, functional outcome, and second-look arthroscopic findings after anterior cruciate ligament reconstruction between remnant-preserving tibialis tendon allograft and remnant-sacrificing hamstring tendon autograft. We matched two groups (remnant-preserving tibialis tendon allograft group and hamstring tendon autograft group) in terms of demographic characteristics, associated injury, and knee characteristics. Each group consisted of 25 patients. Operation time was longer in the remnant-preserving tibialis tendon allograft group, but there was no significant intergroup difference in stability, clinical outcome, and second-look arthroscopic findings. When an autograft is not feasible in anterior cruciate ligament reconstruction, the remnant-preserving technique can produce comparable results in terms of restoration of function, stability of the knee, and degree of synovium coverage at second-look arthroscopy compared to remnant-sacrificing hamstring autograft.
Matoba, Alice Y; Peterson, Jeff R; Wilhelmus, Kirk R
2016-03-01
To describe dendritiform keratopathy associated with exposure to polyquaternium-1, a common preservative found in contact lens solutions and tear replacement products. Case series. Sixteen patients who demonstrated dendritiform keratopathy during topical ophthalmic exposure to polyquaternium-1. Records were reviewed of all patients diagnosed with dendritiform keratopathy between 1999 and 2014 who had documented exposure to contact lens care disinfecting solutions or artificial tear solutions containing polyquaternium-1. Patients were excluded who had coexisting potential causes for dendritiform keratopathy, such as prior herpes simplex keratitis, varicella-zoster viral keratitis, the linear form of Thygeson's superficial keratitis, epithelial regeneration line, Acanthamoeba keratitis, mucus plaque keratopathy, medication-related keratopathy, or limbal stem cell deficiency characterized by conjunctivalization of the corneal epithelium. Effect of discontinuation of exposure to polyquaternium-1 on the dendritiform keratopathy. Sixteen patients demonstrated dendritiform keratopathy after exposure to the preservative polyquaternium-1. Thirteen patients had a history of recent exposure to contact lens disinfecting solutions (Opti-Free, Equate) containing polyquaternium-1. Three patients used a tear replacement product (Systane) containing a polyquaternium-1 preservative. Four patients were treated with antiviral medications for presumed herpes simplex keratitis; 4 patients underwent diagnostic testing for Acanthamoeba keratitis. Two additional patients were diagnosed sequentially with herpes simplex keratitis, then Acanthamoeba keratitis before referral. All dendritiform lesions resolved within 2 to 6 weeks after elimination of exposure to polyquaternium-1. Ophthalmic products containing polyquaternium-1 may cause dendritiform keratopathy that may be confused with infections of the superficial cornea, such as herpes simplex virus keratitis or Acanthamoeba keratitis. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Reproducibility of Digital PCR Assays for Circulating Tumor DNA Analysis in Advanced Breast Cancer
Hrebien, Sarah; O’Leary, Ben; Beaney, Matthew; Schiavon, Gaia; Fribbens, Charlotte; Bhambra, Amarjit; Johnson, Richard; Turner, Nicholas
2016-01-01
Circulating tumor DNA (ctDNA) analysis has the potential to allow non-invasive analysis of tumor mutations in advanced cancer. In this study we assessed the reproducibility of digital PCR (dPCR) assays of circulating tumor DNA in a cohort of patients with advanced breast cancer and assessed delayed plasma processing using cell free DNA preservative tubes. We recruited a cohort of 96 paired samples from 71 women with advanced breast cancer who had paired blood samples processed either immediately or delayed in preservative tubes with processing 48–72 hours after collection. Plasma DNA was analysed with multiplex digital PCR (mdPCR) assays for hotspot mutations in PIK3CA, ESR1 and ERBB2, and for AKT1 E17K. There was 94.8% (91/96) agreement in mutation calling between immediate and delayed processed tubes, kappa 0.88 95% CI 0.77–0.98). Discordance in mutation calling resulted from low allele frequency and likely stochastic effects. In concordant samples there was high correlation in mutant copies per ml plasma (r2 = 0.98; p<0.0001). There was elevation of total cell free plasma DNA concentrations in 10.3% of delayed processed tubes, although overall quantification of total cell free plasma DNA had similar prognostic effects in immediate (HR 3.6) and delayed (HR 3.0) tubes. There was moderate agreement in changes in allele fraction between sequential samples in quantitative mutation tracking (r = 0.84, p = 0.0002). Delayed processing of samples using preservative tubes allows for centralized ctDNA digital PCR mutation screening in advanced breast cancer. The potential of preservative tubes in quantitative mutation tracking requires further research. PMID:27760227
Reproducibility of Digital PCR Assays for Circulating Tumor DNA Analysis in Advanced Breast Cancer.
Hrebien, Sarah; O'Leary, Ben; Beaney, Matthew; Schiavon, Gaia; Fribbens, Charlotte; Bhambra, Amarjit; Johnson, Richard; Garcia-Murillas, Isaac; Turner, Nicholas
2016-01-01
Circulating tumor DNA (ctDNA) analysis has the potential to allow non-invasive analysis of tumor mutations in advanced cancer. In this study we assessed the reproducibility of digital PCR (dPCR) assays of circulating tumor DNA in a cohort of patients with advanced breast cancer and assessed delayed plasma processing using cell free DNA preservative tubes. We recruited a cohort of 96 paired samples from 71 women with advanced breast cancer who had paired blood samples processed either immediately or delayed in preservative tubes with processing 48-72 hours after collection. Plasma DNA was analysed with multiplex digital PCR (mdPCR) assays for hotspot mutations in PIK3CA, ESR1 and ERBB2, and for AKT1 E17K. There was 94.8% (91/96) agreement in mutation calling between immediate and delayed processed tubes, kappa 0.88 95% CI 0.77-0.98). Discordance in mutation calling resulted from low allele frequency and likely stochastic effects. In concordant samples there was high correlation in mutant copies per ml plasma (r2 = 0.98; p<0.0001). There was elevation of total cell free plasma DNA concentrations in 10.3% of delayed processed tubes, although overall quantification of total cell free plasma DNA had similar prognostic effects in immediate (HR 3.6) and delayed (HR 3.0) tubes. There was moderate agreement in changes in allele fraction between sequential samples in quantitative mutation tracking (r = 0.84, p = 0.0002). Delayed processing of samples using preservative tubes allows for centralized ctDNA digital PCR mutation screening in advanced breast cancer. The potential of preservative tubes in quantitative mutation tracking requires further research.
Hardarson, Thorir; Bungum, Mona; Conaghan, Joe; Meintjes, Marius; Chantilis, Samuel J; Molnar, Laszlo; Gunnarsson, Kristina; Wikland, Matts
2015-12-01
To study whether a culture medium that allows undisturbed culture supports human embryo development to the blastocyst stage equivalently to a well-established sequential media. Randomized, double-blinded sibling trial. Independent in vitro fertilization (IVF) clinics. One hundred twenty-eight patients, with 1,356 zygotes randomized into two study arms. Embryos randomly allocated into two study arms to compare embryo development on a time-lapse system using a single-step medium or sequential media. Percentage of good-quality blastocysts on day 5. Percentage of day 5 good-quality blastocysts was 21.1% (standard deviation [SD] ± 21.6%) and 22.2% (SD ± 22.1%) in the single-step time-lapse medium (G-TL) and the sequential media (G-1/G-2) groups, respectively. The mean difference (-1.2; 95% CI, -6.0; 3.6) between the two media systems for the primary end point was less than the noninferiority margin of -8%. There was a statistically significantly lower number of good-quality embryos on day 3 in the G-TL group [50.7% (SD ± 30.6%) vs. 60.8% (SD ± 30.7%)]. Four out of the 11 measured morphokinetic parameters were statistically significantly different for the two media used. The mean levels of ammonium concentration in the media at the end of the culture period was statistically significantly lower in the G-TL group as compared with the G-2 group. We have shown that a single-step culture medium supports blastocyst development equivalently to established sequential media. The ammonium concentrations were lower in the single-step media, and the measured morphokinetic parameters were modified somewhat. NCT01939626. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
S Chapman, Jocelyn; Roddy, Erika; Panighetti, Anna; Hwang, Shelley; Crawford, Beth; Powell, Bethan; Chen, Lee-May
2016-12-01
Women with breast cancer who carry BRCA1 or BRCA2 mutations must also consider risk-reducing salpingo-oophorectomy (RRSO) and how to coordinate this procedure with their breast surgery. We report the factors associated with coordinated versus sequential surgery and compare the outcomes of each. Patients in our cancer risk database who had breast cancer and a known deleterious BRCA1/2 mutation before undergoing breast surgery were included. Women who chose concurrent RRSO at the time of breast surgery were compared to those who did not. Sixty-two patients knew their mutation carrier status before undergoing breast cancer surgery. Forty-three patients (69%) opted for coordinated surgeries, and 19 (31%) underwent sequential surgeries at a median follow-up of 4.4 years. Women who underwent coordinated surgery were significantly older than those who chose sequential surgery (median age of 45 vs. 39 years; P = .025). There were no differences in comorbidities between groups. Patients who received neoadjuvant chemotherapy were more likely to undergo coordinated surgery (65% vs. 37%; P = .038). Sequential surgery patients had longer hospital stays (4.79 vs. 3.44 days, P = .01) and longer operating times (8.25 vs. 6.38 hours, P = .006) than patients who elected combined surgery. Postoperative complications were minor and were no more likely in either group (odds ratio, 4.76; 95% confidence interval, 0.56-40.6). Coordinating RRSO with breast surgery is associated with receipt of neoadjuvant chemotherapy, longer operating times, and hospital stays without an observed increase in complications. In the absence of risk, surgical options can be personalized. Copyright © 2016 Elsevier Inc. All rights reserved.
Shu, Guocheng; Gong, Yuzhou; Xie, Feng; Wu, Nicholas C.
2017-01-01
Measurements of historical specimens are widely applied in studies of taxonomy, systematics, and ecology, but biologists often assume that the effects of preservative chemicals on the morphology of amphibian specimens are minimal in their analyses. We compared the body length and body mass of 182 samples of 13 live and preserved (up to 10 years) anuran species and found that the body length and body mass of preserved specimens significantly decreased by 6.1% and 24.8%, respectively, compared to those measurements of their live counterparts. The changes in body length and mass also exhibited highly significant variations between species. Similarly, there were significant differences in shrinkage of body length and body mass between sexes, where males showed greater shrinkage in body length and body mass compared to females. Preservation distorted the magnitude of the interspecific differences in body length observed in the fresh specimens. Overall, the reduction in body length or mass was greater in longer or heavier individuals. Due to the effects of preservation on amphibian morphology, we propose two parsimonious conversion equations to back-calculate the original body length and body mass of studied anurans for researchers working with historical data, since morphological data from preserved specimens may lead to incorrect biological interpretations when comparing to fresh specimens. Therefore, researchers should correct for errors due to preservation effects that may lead to the misinterpretation of results. PMID:28929024
Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul
2014-07-03
To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P < 0.05) in patients with dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P < 0.05). Treatment with preservative-free eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Mathenjwa, S A; Hugo, C J; Bothma, C; Hugo, A
2012-06-01
Boerewors is a South African fresh sausage preserved with 450mg/kg sulphur dioxide (SO(2)). The preservative effects of rosemary (Ros; 260mg/kg) and chitosan (Chi; 10g/kg) were compared to SO(2). Eight boerewors models were formulated. Microbial, colour, lipid and sensory characteristics were evaluated. Chi and Chi in combination with other preservatives had a significant effect on reducing total bacterial, coliform and Enterobacteriaceae counts, comparable to SO(2). Chi, however, had a better effect on decreasing yeasts and mould counts than SO(2). Chi showed good colour properties comparable to SO(2). Ros showed comparable lipid stability to SO(2) but better when compared to Chi. Ros had a better effect on the sensory taste when compared to Chi, but SO(2) was still preferred. Reduced levels of 100mg/kg SO(2) showed good antimicrobial and colour effects in combination with Chi and in combination with Ros as antioxidant and improving the sensory properties. Alternative preservatives can be used to reduce the SO(2) content of boerewors. Copyright © 2012 Elsevier Ltd. All rights reserved.
Brown, Peter; Pullan, Wayne; Yang, Yuedong; Zhou, Yaoqi
2016-02-01
The three dimensional tertiary structure of a protein at near atomic level resolution provides insight alluding to its function and evolution. As protein structure decides its functionality, similarity in structure usually implies similarity in function. As such, structure alignment techniques are often useful in the classifications of protein function. Given the rapidly growing rate of new, experimentally determined structures being made available from repositories such as the Protein Data Bank, fast and accurate computational structure comparison tools are required. This paper presents SPalignNS, a non-sequential protein structure alignment tool using a novel asymmetrical greedy search technique. The performance of SPalignNS was evaluated against existing sequential and non-sequential structure alignment methods by performing trials with commonly used datasets. These benchmark datasets used to gauge alignment accuracy include (i) 9538 pairwise alignments implied by the HOMSTRAD database of homologous proteins; (ii) a subset of 64 difficult alignments from set (i) that have low structure similarity; (iii) 199 pairwise alignments of proteins with similar structure but different topology; and (iv) a subset of 20 pairwise alignments from the RIPC set. SPalignNS is shown to achieve greater alignment accuracy (lower or comparable root-mean squared distance with increased structure overlap coverage) for all datasets, and the highest agreement with reference alignments from the challenging dataset (iv) above, when compared with both sequentially constrained alignments and other non-sequential alignments. SPalignNS was implemented in C++. The source code, binary executable, and a web server version is freely available at: http://sparks-lab.org yaoqi.zhou@griffith.edu.au. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Giesen, Carina; Eberhard, Maike; Rothermund, Klaus
2015-06-01
It is commonly assumed that attentional inhibitory functioning decreases with age, even though empirical evidence is mixed. These inconsistencies possibly stem from methodological artifacts: distractor inhibition is typically assessed with the negative priming paradigm, which confounds inhibition and episodic retrieval. In the present study, we investigated age differences in a sequential distractor repetition paradigm (Giesen, Frings, & Rothermund, 2012) that provides independent estimates of distractor inhibition and episodic retrieval processes. Older (60+ yrs) and younger (below 30 years) adults identified target letters that were flanked by distractors (JKJ). Inhibitory processes were preserved in older adults, who showed reliable distractor repetition benefits resulting from persistent distractor inhibition; however, a significant loss of inhibition was apparent for the older subgroup of participants (65+ yrs) compared with a subgroup of young-old participants (60 to 64 years). No age differences were found for episodic retrieval processes of stimulus-response bindings that were indexed by an interaction of distractor repetition and response relation. Findings highlight the importance of dissociating between distractor inhibition and retrieval processes that are differently implicated in age-related cognitive change. (c) 2015 APA, all rights reserved.
Ji, Qiang; Shi, YunQing; Xia, LiMin; Ma, RunHua; Shen, JinQiang; Lai, Hao; Ding, WenJun; Wang, ChunSheng
2017-12-25
To evaluate in-hospital and mid-term outcomes of sequential vs. separate grafting of in situ skeletonized left internal mammary artery (LIMA) to the left coronary system in a single-center, propensity-matched study.Methods and Results:After propensity score-matching, 120 pairs of patients undergoing first scheduled isolated coronary artery bypass grafting (CABG) with in situ skeletonized LIMA grafting to the left anterior descending artery (LAD) territory were entered into a sequential group (sequential grafting of LIMA to the diagonal artery and then to the LAD) or a control group (separate grafting of LIMA to the LAD). The in-hospital and follow-up clinical outcomes and follow-up LIMA graft patency were compared. Both propensity score-matched groups had similar in-hospital and follow-up clinical outcomes. Sequential LIMA grafting was not found to be an independent predictor of adverse events. During a follow-up period of 27.0±7.3 months, 99.1% patency for the diagonal site and 98.3% for the LAD site were determined by coronary computed tomographic angiography after sequential LIMA grafting, both of which were similar with graft patency of separate grafting of in situ skeletonized LIMA to the LAD. Revascularization of the left coronary system using a skeletonized LIMA resulted in excellent in-hospital and mid-term clinical outcomes and graft patency using sequential grafting.
Hajati, Omid; Zarrabi, Khalil; Karimi, Reza; Hajati, Azadeh
2012-01-01
There is still controversy over the differences in the patency rates of the sequential and individual coronary artery bypass grafting (CABG) techniques. The purpose of this paper was to non-invasively evaluate hemodynamic parameters using complete 3D computational fluid dynamics (CFD) simulations of the sequential and the individual methods based on the patient-specific data extracted from computed tomography (CT) angiography. For CFD analysis, the geometric model of coronary arteries was reconstructed using an ECG-gated 64-detector row CT. Modeling the sequential and individual bypass grafting, this study simulates the flow from the aorta to the occluded posterior descending artery (PDA) and the posterior left ventricle (PLV) vessel with six coronary branches based on the physiologically measured inlet flow as the boundary condition. The maximum calculated wall shear stress (WSS) in the sequential and the individual models were estimated to be 35.1 N/m(2) and 36.5 N/m(2), respectively. Compared to the individual bypass method, the sequential graft has shown a higher velocity at the proximal segment and lower spatial wall shear stress gradient (SWSSG) due to the flow splitting caused by the side-to-side anastomosis. Simulated results combined with its surgical benefits including the requirement of shorter vein length and fewer anastomoses advocate the sequential method as a more favorable CABG method.
Enhancing lineup identification accuracy: two codes are better than one.
Melara, R D; DeWitt-Rickards, T S; O'Brien, T P
1989-10-01
Ways of improving identification accuracy were explored by comparing the conventional visual lineup with an auditory/visual lineup, one that paired color photographs with voice recordings. This bimodal lineup necessitated sequential presentation of lineup members; Experiment 1 showed that performance in sequential lineups was better than performance in traditional simultaneous lineups. In Experiments 2A and 2B unimodal and bimodal lineups were compared by using a multiple-lineup paradigm: Ss viewed 3 videotaped episodes depicting standard police procedures and were tested in 4 sequential lineups. Bimodal lineups were more diagnostic than either visual or auditory lineups alone. The bimodal lineup led to a 126% improvement in number of correct identifications over the conventional visual lineup, with no concomitant increase in number of false identifications. These results imply strongly that bimodal procedures should be adopted in real-world lineups. The nature of memorial processes underlying this bimodal advantage is discussed.
Posner, M R; Lorch, J H; Goloubeva, O; Tan, M; Schumaker, L M; Sarlis, N J; Haddad, R I; Cullen, K J
2011-05-01
The association between human papillomavirus (HPV) and overall survival (OS) in oropharynx cancer (OPC) was retrospectively examined in TAX 324, a phase III trial of sequential therapy for locally advanced head and neck cancer. Accrual for TAX 324 was completed in 2003 and data updated through 2008. Pretherapy tumor biopsies were studied by PCR for human papillomavirus type 16 and linked to OS, progression-free survival (PFS) and demographics. Of 264 patients with OPC, 111 (42%) had evaluable biopsies; 56 (50%) were HPV+ and 55 (50%) were HPV-. HPV+ patients were significantly younger (54 versus 58 years, P = 0.02), had T1/T2 primary cancers (49% versus 20%, P = 0.001), and had a performance status of zero (77% versus 49%, P = 0.003). OS and PFS were better for HPV+ patients (OS, hazard ratio = 0.20, P < 0.0001). Local-regional failure was less in HPV+ patients (13% versus 42%, P = 0.0006); at 5 years, 82% of HPV+ patients were alive compared with 35% of HPV- patients (P < 0.0001). HPV+ OPC has a different biology compared with HPV- OPC; 5-year OS, PFS, and local-regional control are unprecedented. These results support the possibility of selectively reducing therapy and long-term morbidity in HPV+ OPC while preserving survival and approaching HPV- disease with more aggressive treatment.
An algorithm for propagating the square-root covariance matrix in triangular form
NASA Technical Reports Server (NTRS)
Tapley, B. D.; Choe, C. Y.
1976-01-01
A method for propagating the square root of the state error covariance matrix in lower triangular form is described. The algorithm can be combined with any triangular square-root measurement update algorithm to obtain a triangular square-root sequential estimation algorithm. The triangular square-root algorithm compares favorably with the conventional sequential estimation algorithm with regard to computation time.
Deposition on disordered substrates with precursor layer diffusion
NASA Astrophysics Data System (ADS)
Filipe, J. A. N.; Rodgers, G. J.; Tavassoli, Z.
1998-09-01
Recently we introduced a one-dimensional accelerated random sequential adsorption process as a model for chemisorption with precursor layer diffusion. In this paper we consider this deposition process on disordered or impure substrates. The problem is solved exactly on both the lattice and continuum and for various impurity distributions. The results are compared with those from the standard random sequential adsorption model.
Comparing multiple imputation methods for systematically missing subject-level data.
Kline, David; Andridge, Rebecca; Kaizar, Eloise
2017-06-01
When conducting research synthesis, the collection of studies that will be combined often do not measure the same set of variables, which creates missing data. When the studies to combine are longitudinal, missing data can occur on the observation-level (time-varying) or the subject-level (non-time-varying). Traditionally, the focus of missing data methods for longitudinal data has been on missing observation-level variables. In this paper, we focus on missing subject-level variables and compare two multiple imputation approaches: a joint modeling approach and a sequential conditional modeling approach. We find the joint modeling approach to be preferable to the sequential conditional approach, except when the covariance structure of the repeated outcome for each individual has homogenous variance and exchangeable correlation. Specifically, the regression coefficient estimates from an analysis incorporating imputed values based on the sequential conditional method are attenuated and less efficient than those from the joint method. Remarkably, the estimates from the sequential conditional method are often less efficient than a complete case analysis, which, in the context of research synthesis, implies that we lose efficiency by combining studies. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Analyzing multicomponent receptive fields from neural responses to natural stimuli
Rowekamp, Ryan; Sharpee, Tatyana O
2011-01-01
The challenge of building increasingly better models of neural responses to natural stimuli is to accurately estimate the multiple stimulus features that may jointly affect the neural spike probability. The selectivity for combinations of features is thought to be crucial for achieving classical properties of neural responses such as contrast invariance. The joint search for these multiple stimulus features is difficult because estimating spike probability as a multidimensional function of stimulus projections onto candidate relevant dimensions is subject to the curse of dimensionality. An attractive alternative is to search for relevant dimensions sequentially, as in projection pursuit regression. Here we demonstrate using analytic arguments and simulations of model cells that different types of sequential search strategies exhibit systematic biases when used with natural stimuli. Simulations show that joint optimization is feasible for up to three dimensions with current algorithms. When applied to the responses of V1 neurons to natural scenes, models based on three jointly optimized dimensions had better predictive power in a majority of cases compared to dimensions optimized sequentially, with different sequential methods yielding comparable results. Thus, although the curse of dimensionality remains, at least several relevant dimensions can be estimated by joint information maximization. PMID:21780916
Comparing five simple vascular storage protocols.
van Doormaal, Tristan P C; Sluijs, Jurren H; Vink, Aryan; Tulleken, Cornelis A F; van der Zwan, Albert
2014-11-01
We aim to find a storage protocol for vessels that preserves their dimensional, histologic, and mechanical characteristics to facilitate reproducible anastomosis experiments and microsurgical training with constant quality. We compared stored rabbit aortas, harvested in a slaughterhouse, using five different protocols with fresh controls. Aortas were preserved for 125 d in (1) NaCl 0.9% at -18°C, (2) Roswell Park Memorial Institute 1640 90% with 10% dimethyl sulfoxide (RPMI/DMSO) at -18°C, (3) RPMI/DMSO at -70°C, (4) glycerol 85% at 4°C, and (5) glycerol in stepwise increased concentrations until 85% at 4°C. After preservation, we measured vessel diameter, wall thickness, and Young's Modulus indicating stiffness. Neurosurgeons compared stored vessels with fresh vessels, blinded for preservation subgroup. We performed histologic assessment blinded for preservation subgroup. Fresh rabbit aortas showed a mean diameter of 2.65 ± 0.14 mm, a mean wall thickness of 126 ± 22 μm, and a Young's Modulus of 11.4 ± 2.4 N/mm(2). NaCl 0.9%-preserved aortas showed a significantly increased vessel diameter and decreased stiffness. RPMI/DMSO-preserved aortas showed no significant differences from fresh aortas in dimensions and mechanical characteristics. Glycerol-preserved tissue showed a significant increase in wall thickness, a related significant decrease in diameter, and increase in stiffness. Neurosurgeons regarded RPMI/DMSO tissue as most comparable with fresh tissue. Histologic assessment revealed no differences between the different protocols and fresh control group. Storage of rabbit aortas in RPMI/DMSO most adequately preserves their dimensional and mechanical properties. Copyright © 2014 Elsevier Inc. All rights reserved.
Garatti, Andrea; Castelvecchio, Serenella; Canziani, Alberto; Corain, Livio; Generali, Tommaso; Mossuto, Eugenio; Gagliardotto, Piervincenzo; Anastasia, Luigi; Salmaso, Luigi; Giacomazzi, Francesca; Menicanti, Lorenzo
2014-12-01
The aim of the study was to analyse the early and long-term outcomes of a consecutive series of patients who underwent sequential coronary artery bypass grafting (CABG) and to compare them with a matched population of totally arterial revascularized patients. From January 1994 to December 1996, 209 patients underwent total arterial myocardial revascularization at our institution [arterial (ART) group]. In the same period, 2097 patients underwent CABG with left internal thoracic artery on left anterior descending and great saphenous vein on the right and circumflex branches sequentially [sequential vein (SV) group]. The propensity score methodology was used to obtain risk-adjusted outcome comparisons between the two groups (209 vs 243 patients in the ART group and SV group, respectively). In-hospital mortality was 1% in the ART group and 0.4% in the SV group (P = 0.86). Mean follow-up was 14 ± 4 years. Long-term survival was comparable among the two study groups [actuarial 5- and 15-year survival rates were 97 vs 93% and 82 vs 79% in the ART group and the SV group, respectively (P = 0.29)]. At follow-up, recurrence of angina (17 vs 18%; P = 0.99), acute myocardial infarction (MI) (3 vs 5%; P = 0.72) and repeated percutaneous coronary intervention (19 vs 21%; P = 0.69) were similar in the ART group compared with the SV group. In the Cox regression analysis, type of revascularization was not an independent predictor of any long-term outcomes (death or major adverse cardiac events). In asymptomatic patients, exercise stress test at follow-up was comparable between the two groups (P = 0.14). Sequential vein CABG appears to have good early and long-term clinical outcomes. Also, early and long-term incidence of acute MI was not significantly higher in the SV group. However, further studies with a larger population are warranted in order to confirm the present results. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Wild, Aaron T; Gandhi, Nishant; Chettiar, Sivarajan T; Aziz, Khaled; Gajula, Rajendra P; Williams, Russell D; Kumar, Rachit; Taparra, Kekoa; Zeng, Jing; Cades, Jessica A; Velarde, Esteban; Menon, Siddharth; Geschwind, Jean F; Cosgrove, David; Pawlik, Timothy M; Maitra, Anirban; Wong, John; Hales, Russell K; Torbenson, Michael S; Herman, Joseph M; Tran, Phuoc T
2013-01-01
Sorafenib (SOR) is the only systemic agent known to improve survival for hepatocellular carcinoma (HCC). However, SOR prolongs survival by less than 3 months and does not alter symptomatic progression. To improve outcomes, several phase I-II trials are currently examining SOR with radiation (RT) for HCC utilizing heterogeneous concurrent and sequential treatment regimens. Our study provides preclinical data characterizing the effects of concurrent versus sequential RT-SOR on HCC cells both in vitro and in vivo. Concurrent and sequential RT-SOR regimens were tested for efficacy among 4 HCC cell lines in vitro by assessment of clonogenic survival, apoptosis, cell cycle distribution, and γ-H2AX foci formation. Results were confirmed in vivo by evaluating tumor growth delay and performing immunofluorescence staining in a hind-flank xenograft model. In vitro, concurrent RT-SOR produced radioprotection in 3 of 4 cell lines, whereas sequential RT-SOR produced decreased colony formation among all 4. Sequential RT-SOR increased apoptosis compared to RT alone, while concurrent RT-SOR did not. Sorafenib induced reassortment into less radiosensitive phases of the cell cycle through G1-S delay and cell cycle slowing. More double-strand breaks (DSBs) persisted 24 h post-irradiation for RT alone versus concurrent RT-SOR. In vivo, sequential RT-SOR produced the greatest tumor growth delay, while concurrent RT-SOR was similar to RT alone. More persistent DSBs were observed in xenografts treated with sequential RT-SOR or RT alone versus concurrent RT-SOR. Sequential RT-SOR additionally produced a greater reduction in xenograft tumor vascularity and mitotic index than either concurrent RT-SOR or RT alone. In conclusion, sequential RT-SOR demonstrates greater efficacy against HCC than concurrent RT-SOR both in vitro and in vivo. These results may have implications for clinical decision-making and prospective trial design.
Chettiar, Sivarajan T.; Aziz, Khaled; Gajula, Rajendra P.; Williams, Russell D.; Kumar, Rachit; Taparra, Kekoa; Zeng, Jing; Cades, Jessica A.; Velarde, Esteban; Menon, Siddharth; Geschwind, Jean F.; Cosgrove, David; Pawlik, Timothy M.; Maitra, Anirban; Wong, John; Hales, Russell K.; Torbenson, Michael S.; Herman, Joseph M.; Tran, Phuoc T.
2013-01-01
Sorafenib (SOR) is the only systemic agent known to improve survival for hepatocellular carcinoma (HCC). However, SOR prolongs survival by less than 3 months and does not alter symptomatic progression. To improve outcomes, several phase I-II trials are currently examining SOR with radiation (RT) for HCC utilizing heterogeneous concurrent and sequential treatment regimens. Our study provides preclinical data characterizing the effects of concurrent versus sequential RT-SOR on HCC cells both in vitro and in vivo. Concurrent and sequential RT-SOR regimens were tested for efficacy among 4 HCC cell lines in vitro by assessment of clonogenic survival, apoptosis, cell cycle distribution, and γ-H2AX foci formation. Results were confirmed in vivo by evaluating tumor growth delay and performing immunofluorescence staining in a hind-flank xenograft model. In vitro, concurrent RT-SOR produced radioprotection in 3 of 4 cell lines, whereas sequential RT-SOR produced decreased colony formation among all 4. Sequential RT-SOR increased apoptosis compared to RT alone, while concurrent RT-SOR did not. Sorafenib induced reassortment into less radiosensitive phases of the cell cycle through G1-S delay and cell cycle slowing. More double-strand breaks (DSBs) persisted 24 h post-irradiation for RT alone versus concurrent RT-SOR. In vivo, sequential RT-SOR produced the greatest tumor growth delay, while concurrent RT-SOR was similar to RT alone. More persistent DSBs were observed in xenografts treated with sequential RT-SOR or RT alone versus concurrent RT-SOR. Sequential RT-SOR additionally produced a greater reduction in xenograft tumor vascularity and mitotic index than either concurrent RT-SOR or RT alone. In conclusion, sequential RT-SOR demonstrates greater efficacy against HCC than concurrent RT-SOR both in vitro and in vivo. These results may have implications for clinical decision-making and prospective trial design. PMID:23762417
Nasa, Mukesh; Choksey, Ajay; Phadke, Aniruddha; Sawant, Prabha
2013-11-01
Antimicrobial resistance has decreased eradication rates for Helicobacter pylori infection worldwide. A sequential treatment schedule has been reported to be effective, but studies published to date were performed in Italy. We undertook this study to determine whether these results could be replicated in India. A randomized, open-labeled, prospective controlled trial comparing sequential vs. standard triple-drug therapy was carried out at Lokmanya Tilak Municipal General Hospital, Mumbai. Two hundred and thirty-one patients with dyspepsia were randomized to a 10-day sequential regimen (40 mg of pantoprazole, 1 g of amoxicillin, each administered twice daily for the first 5 days, followed by 40 mg of pantoprazole, 500 mg of clarithromycin, and 500 mg of tinidazole, each administered twice daily for the remaining 5 days) or to standard 14-day therapy (40 mg of pantoprazole, 500 mg of clarithromycin, and 1 g of amoxicillin, each administered twice daily). The eradication rate achieved with the sequential regimen was significantly greater than that obtained with the triple therapy. Per-protocol eradication rate of sequential therapy was 92.4% (95% CI 85.8-96.1%) vs. 81.8% (95% CI 73.9-87.8%) (p = 0.027) for standard drug therapy. Intention-to-treat eradication rates were 88.2% (95% CI 80.9-93.0%) vs. 79.1% (95% CI 71.1-85.4%), p = 0.029, respectively. The incidence of major and minor side effects between therapy groups was not significantly different (14.6% in the triple therapy group vs. 23.5% in sequential group, p = 0.12). Follow up was incomplete in 3.3% and 4.7% patients in standard and sequential therapy groups, respectively. Sequential therapy includes one additional antibiotic (tinidazole) that is not contained in standard therapy. Sequential therapy was significantly better than standard therapy for eradicating H. pylori infection.
NASA Astrophysics Data System (ADS)
Grum-Grzhimailo, A. N.; Gryzlova, E. V.; Kuzmina, E. I.; Chetverkina, A. S.; Strakhova, S. I.
2015-04-01
Two nonlinear atomic photoprocesses are theoretically considered with the emphasis on the photoelectron angular distributions and their modifications due to violation of the dipole approximation: sequential two-photon double ionization and two-color above threshold ionization. These reactions are now accessible with X-ray free electron lasers. Both processes are exemplified by the ionization of krypton: from the 4p shell in the sequential two-photon double ionization and from the 2s shell in the two-color above-threshold ionization, which are compared to the Ar(3p) and Ne(1s) ionization, respectively. Noticeable nondipole effects are predicted.
Arguedas, A; Soley, C; Loaiza, C; Rincon, G; Guevara, S; Perez, A; Porras, W; Alvarado, O; Aguilar, L; Abdelnour, A; Grunwald, U; Bedell, L; Anemona, A; Dull, P M
2010-04-19
This Phase III study evaluates an investigational quadrivalent meningococcal CRM(197) conjugate vaccine, MenACWY-CRM (Novartis Vaccines), when administered concomitantly or sequentially with two other recommended adolescent vaccines; combined tetanus, reduced diphtheria and acellular pertussis (Tdap), and human papillomavirus (HPV) vaccine. In this single-centre study, 1620 subjects 11-18 years of age, were randomized to three groups (1:1:1) to receive MenACWY-CRM concomitantly or sequentially with Tdap and HPV. Meningococcal serogroup-specific serum bactericidal assay using human complement (hSBA), and antibodies to Tdap antigens and HPV virus-like particles were determined before and 1 month after study vaccinations. Proportions of subjects with hSBA titres > or =1:8 for all four meningococcal serogroups (A, C, W-135, Y) were non-inferior for both concomitant and sequential administration. Immune responses to Tdap and HPV antigens were comparable when these vaccines were given alone or concomitantly with MenACWY-CRM. All vaccines were well tolerated; concomitant or sequential administration did not increase reactogenicity. MenACWY-CRM was well tolerated and immunogenic in subjects 11-18 years of age, with comparable immune responses to the four serogroups when given alone or concomitantly with Tdap or HPV antigens. This is the first demonstration that these currently recommended adolescent vaccines could be administered concomitantly without causing increased reactogenicity. Copyright 2010 Elsevier Ltd. All rights reserved.
Dave, Hreem; Phoenix, Vidya; Becker, Edmund R; Lambert, Scott R
2010-08-01
To compare the incidence of adverse events and visual outcomes and to compare the economic costs of sequential vs simultaneous bilateral cataract surgery for infants with congenital cataracts. Retrospective review of simultaneous vs sequential bilateral cataract surgery for infants with congenital cataracts who underwent cataract surgery when 6 months or younger at our institution. Records were available for 10 children who underwent sequential surgery at a mean age of 49 days for the first eye and 17 children who underwent simultaneous surgery at a mean age of 68 days (P = .25). We found a similar incidence of adverse events between the 2 treatment groups. Intraoperative or postoperative complications occurred in 14 eyes. The most common postoperative complication was glaucoma. No eyes developed endophthalmitis. The mean (SD) absolute interocular difference in logMAR visual acuities between the 2 treatment groups was 0.47 (0.76) for the sequential group and 0.44 (0.40) for the simultaneous group (P = .92). Payments for the hospital, drugs, supplies, and professional services were on average 21.9% lower per patient in the simultaneous group. Simultaneous bilateral cataract surgery for infants with congenital cataracts is associated with a 21.9% reduction in medical payments and no discernible difference in the incidence of adverse events or visual outcomes. However, our small sample size limits our ability to make meaningful comparisons of the relative risks and visual benefits of the 2 procedures.
Quality assurance in head and neck surgical oncology: EORTC 24954 trial on larynx preservation.
Leemans, C R; Tijink, B M; Langendijk, J A; Andry, G; Hamoir, M; Lefebvre, J L
2013-09-01
The Head and Neck Cancer Group (HNCG) of the EORTC conducted a quality assurance program in the EORTC 24954 trial on larynx preservation. In this multicentre study, patients with resectable advanced squamous cell carcinoma of the larynx or hypopharynx were randomly assigned for treatment with sequential or alternating chemoradiation. The need for a quality assurance program is the evaluation and prevention of differences in treatments between centres in this multidisciplinary study. The surgical subcommittee of the HNCG prepared a questionnaire, and clinical records of all patients were verified during audits of independent teams. Data relating institutional practices were collected during a face to face interview with members of the local team. 271 clinical records from the nine main contributing centres were reviewed. The main difference between centres was the time interval between first consultation and treatment initiation, with a mean of 45 days. On the pathology report the nodal involvement was described by level in 36% of the cases according to the American Academy of Otolaryngology-Head and Neck Surgery classification. Extranodal spread was not always described in neck dissection specimens. The EORTC 24954 trial on larynx preservation was the first prospective trial with a quality assurance program in head and neck surgical oncology. The analysis shows similarities in practices, but also points out some important differences between centres. Operation reports were fairly complete, but uniformity in pathology reports should be improved. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sherwood, Mark Brian
2006-01-01
Purpose The purpose of this study was to evaluate the concept of targeting mediators of the scarring process at multiple points across the course of bleb failure, in order to prolong bleb survival. Methods There were three linked parts to the experiment. In the first part, a cannula glaucoma filtration surgery (GFS) was performed on 32 New Zealand White (NZW) rabbits, and bleb survival was assessed for six different regimens plus controls by grading bleb height and width. For the second part of the study, the same GFS surgery was performed on an additional 10 NZW rabbits. Two additional filtering blebs were treated with balanced saline solution (BSS), two received mitomycin-C (MMC) (0.4 mg/mL), and for the remaining six, a sequential regimen was given consisting of 200 mmol/L mannose-6-phosphate (M-6-P) solution at the time of surgery, followed by subconjunctival injections of antibody to connective tissue growth factor at days 2 and 4, and Ilomastat, a broad-spectrum matrix metalloproteinase inhibitor, at days 7, 12, and 20 postoperatively. Bleb survival was again assessed. In the final part of the experiment, blebs treated with either BSS, MMC, or the above sequential multitreatment regimen were examined histologically at 14 days postoperatively in three additional NZW rabbits. Results All six individual therapies selected resulted in some improvement of bleb survival compared to BSS control. Blebs treated with the new sequential, multitreatment protocol survived an average of 29 days (regression slope, P < .0001 compared to control), those receiving BSS an average of 17 days, and those treated with MMC (0.4 mg/mL) an average of 36 days. The sequential, multitreatment regimen was significantly superior to any of the six monotherapies for time to zero analysis (flattening) of the bleb (P < .002). Histologic examination of the bleb tissues showed a markedly less epithelial thinning, subepithelial collagen thinning, and goblet cell loss in the multitreatment group, when compared with the MMC blebs. Conclusions In a rabbit model of GFS, a sequential, targeted, multitreatment approach prolonged bleb survival compared to BSS controls and decreased bleb tissue morphological changes when compared to those treated with MMC. It is not known whether these findings can be reproduced in humans, and further work is needed to determine an optimum regimen and timing of therapeutic delivery. PMID:17471357
Rochau, Ursula; Sroczynski, Gaby; Wolf, Dominik; Schmidt, Stefan; Jahn, Beate; Kluibenschaedl, Martina; Conrads-Frank, Annette; Stenehjem, David; Brixner, Diana; Radich, Jerald; Gastl, Günther; Siebert, Uwe
2015-01-01
Several tyrosine kinase inhibitors (TKIs) are approved for chronic myeloid leukemia (CML) therapy. We evaluated the long-term cost-effectiveness of seven sequential therapy regimens for CML in Austria. A cost-effectiveness analysis was performed using a state-transition Markov model. As model parameters, we used published trial data, clinical, epidemiological and economic data from the Austrian CML registry and national databases. We performed a cohort simulation over a life-long time-horizon from a societal perspective. Nilotinib without second-line TKI yielded an incremental cost-utility ratio of 121,400 €/quality-adjusted life year (QALY) compared to imatinib without second-line TKI after imatinib failure. Imatinib followed by nilotinib after failure resulted in 131,100 €/QALY compared to nilotinib without second-line TKI. Nilotinib followed by dasatinib yielded 152,400 €/QALY compared to imatinib followed by nilotinib after failure. Remaining strategies were dominated. The sequential application of TKIs is standard-of-care, and thus, our analysis points toward imatinib followed by nilotinib as the most cost-effective strategy.
NASA Astrophysics Data System (ADS)
Park, Hyun-Woo; Song, Aeran; Kwon, Sera; Choi, Dukhyun; Kim, Younghak; Jun, Byung-Hyuk; Kim, Han-Ki; Chung, Kwun-Bum
2018-03-01
This study suggests a sequential ambient annealing process as an excellent post-treatment method to enhance the device performance and stability of W (tungsten) doped InZnO thin film transistors (WIZO-TFTs). Sequential ambient annealing at 250 °C significantly enhanced the device performance and stability of WIZO-TFTs, compared with other post-treatment methods, such as air ambient annealing and vacuum ambient annealing at 250 °C. To understand the enhanced device performance and stability of WIZO-TFT with sequential ambient annealing, we investigate the correlations between device performance and stability and electronic structures, such as band alignment, a feature of the conduction band, and band edge states below the conduction band. The enhanced performance of WIZO-TFTs with sequential ambient annealing is related to the modification of the electronic structure. In addition, the dominant mechanism responsible for the enhanced device performance and stability of WIZO-TFTs is considered to be a change in the shallow-level and deep-level band edge states below the conduction band.
Numerical study on the sequential Bayesian approach for radioactive materials detection
NASA Astrophysics Data System (ADS)
Qingpei, Xiang; Dongfeng, Tian; Jianyu, Zhu; Fanhua, Hao; Ge, Ding; Jun, Zeng
2013-01-01
A new detection method, based on the sequential Bayesian approach proposed by Candy et al., offers new horizons for the research of radioactive detection. Compared with the commonly adopted detection methods incorporated with statistical theory, the sequential Bayesian approach offers the advantages of shorter verification time during the analysis of spectra that contain low total counts, especially in complex radionuclide components. In this paper, a simulation experiment platform implanted with the methodology of sequential Bayesian approach was developed. Events sequences of γ-rays associating with the true parameters of a LaBr3(Ce) detector were obtained based on an events sequence generator using Monte Carlo sampling theory to study the performance of the sequential Bayesian approach. The numerical experimental results are in accordance with those of Candy. Moreover, the relationship between the detection model and the event generator, respectively represented by the expected detection rate (Am) and the tested detection rate (Gm) parameters, is investigated. To achieve an optimal performance for this processor, the interval of the tested detection rate as a function of the expected detection rate is also presented.
Yu, Yinan; Diamantaras, Konstantinos I; McKelvey, Tomas; Kung, Sun-Yuan
2018-02-01
In kernel-based classification models, given limited computational power and storage capacity, operations over the full kernel matrix becomes prohibitive. In this paper, we propose a new supervised learning framework using kernel models for sequential data processing. The framework is based on two components that both aim at enhancing the classification capability with a subset selection scheme. The first part is a subspace projection technique in the reproducing kernel Hilbert space using a CLAss-specific Subspace Kernel representation for kernel approximation. In the second part, we propose a novel structural risk minimization algorithm called the adaptive margin slack minimization to iteratively improve the classification accuracy by an adaptive data selection. We motivate each part separately, and then integrate them into learning frameworks for large scale data. We propose two such frameworks: the memory efficient sequential processing for sequential data processing and the parallelized sequential processing for distributed computing with sequential data acquisition. We test our methods on several benchmark data sets and compared with the state-of-the-art techniques to verify the validity of the proposed techniques.
Self-Consistent Chaotic Transport in a High-Dimensional Mean-Field Hamiltonian Map Model
Martínez-del-Río, D.; del-Castillo-Negrete, D.; Olvera, A.; ...
2015-10-30
We studied the self-consistent chaotic transport in a Hamiltonian mean-field model. This model provides a simplified description of transport in marginally stable systems including vorticity mixing in strong shear flows and electron dynamics in plasmas. Self-consistency is incorporated through a mean-field that couples all the degrees-of-freedom. The model is formulated as a large set of N coupled standard-like area-preserving twist maps in which the amplitude and phase of the perturbation, rather than being constant like in the standard map, are dynamical variables. Of particular interest is the study of the impact of periodic orbits on the chaotic transport and coherentmore » structures. Furthermore, numerical simulations show that self-consistency leads to the formation of a coherent macro-particle trapped around the elliptic fixed point of the system that appears together with an asymptotic periodic behavior of the mean field. To model this asymptotic state, we introduced a non-autonomous map that allows a detailed study of the onset of global transport. A turnstile-type transport mechanism that allows transport across instantaneous KAM invariant circles in non-autonomous systems is discussed. As a first step to understand transport, we study a special type of orbits referred to as sequential periodic orbits. Using symmetry properties we show that, through replication, high-dimensional sequential periodic orbits can be generated starting from low-dimensional periodic orbits. We show that sequential periodic orbits in the self-consistent map can be continued from trivial (uncoupled) periodic orbits of standard-like maps using numerical and asymptotic methods. Normal forms are used to describe these orbits and to find the values of the map parameters that guarantee their existence. Numerical simulations are used to verify the prediction from the asymptotic methods.« less
The effects of sequential attention shifts within visual working memory
Li, Qi; Saiki, Jun
2014-01-01
Previous studies have shown conflicting data as to whether it is possible to sequentially shift spatial attention among visual working memory (VWM) representations. The present study investigated this issue by asynchronously presenting attentional cues during the retention interval of a change detection task. In particular, we focused on two types of sequential attention shifts: (1) orienting attention to one location, and then withdrawing attention from it, and (2) switching the focus of attention from one location to another. In Experiment 1, a withdrawal cue was presented after a spatial retro-cue to measure the effect of withdrawing attention. The withdrawal cue significantly reduced the cost of invalid spatial cues, but surprisingly, did not attenuate the benefit of valid spatial cues. This indicates that the withdrawal cue only triggered the activation of facilitative components but not inhibitory components of attention. In Experiment 2, two spatial retro-cues were presented successively to examine the effect of switching the focus of attention. We observed equivalent benefits of the first and second spatial cues, suggesting that participants were able to reorient attention from one location to another within VWM, and the reallocation of attention did not attenuate memory at the first-cued location. In Experiment 3, we found that reducing the validity of the preceding spatial cue did lead to a significant reduction in its benefit. However, performance was still better at first-cued locations than at uncued and neutral locations, indicating that the first cue benefit might have been preserved both partially under automatic control and partially under voluntary control. Our findings revealed new properties of dynamic attentional control in VWM maintenance. PMID:25237306
Self-Consistent Chaotic Transport in a High-Dimensional Mean-Field Hamiltonian Map Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martínez-del-Río, D.; del-Castillo-Negrete, D.; Olvera, A.
We studied the self-consistent chaotic transport in a Hamiltonian mean-field model. This model provides a simplified description of transport in marginally stable systems including vorticity mixing in strong shear flows and electron dynamics in plasmas. Self-consistency is incorporated through a mean-field that couples all the degrees-of-freedom. The model is formulated as a large set of N coupled standard-like area-preserving twist maps in which the amplitude and phase of the perturbation, rather than being constant like in the standard map, are dynamical variables. Of particular interest is the study of the impact of periodic orbits on the chaotic transport and coherentmore » structures. Furthermore, numerical simulations show that self-consistency leads to the formation of a coherent macro-particle trapped around the elliptic fixed point of the system that appears together with an asymptotic periodic behavior of the mean field. To model this asymptotic state, we introduced a non-autonomous map that allows a detailed study of the onset of global transport. A turnstile-type transport mechanism that allows transport across instantaneous KAM invariant circles in non-autonomous systems is discussed. As a first step to understand transport, we study a special type of orbits referred to as sequential periodic orbits. Using symmetry properties we show that, through replication, high-dimensional sequential periodic orbits can be generated starting from low-dimensional periodic orbits. We show that sequential periodic orbits in the self-consistent map can be continued from trivial (uncoupled) periodic orbits of standard-like maps using numerical and asymptotic methods. Normal forms are used to describe these orbits and to find the values of the map parameters that guarantee their existence. Numerical simulations are used to verify the prediction from the asymptotic methods.« less
Sols, Ignasi; DuBrow, Sarah; Davachi, Lila; Fuentemilla, Lluís
2017-11-20
Although everyday experiences unfold continuously over time, shifts in context, or event boundaries, can influence how those events come to be represented in memory [1-4]. Specifically, mnemonic binding across sequential representations is more challenging at context shifts, such that successful temporal associations are more likely to be formed within than across contexts [1, 2, 5-9]. However, in order to preserve a subjective sense of continuity, it is important that the memory system bridge temporally adjacent events, even if they occur in seemingly distinct contexts. Here, we used pattern similarity analysis to scalp electroencephalographic (EEG) recordings during a sequential learning task [2, 3] in humans and showed that the detection of event boundaries triggered a rapid memory reinstatement of the just-encoded sequence episode. Memory reactivation was detected rapidly (∼200-800 ms from the onset of the event boundary) and was specific to context shifts that were preceded by an event sequence with episodic content. Memory reinstatement was not observed during the sequential encoding of events within an episode, indicating that memory reactivation was induced specifically upon context shifts. Finally, the degree of neural similarity between neural responses elicited during sequence encoding and at event boundaries correlated positively with participants' ability to later link across sequences of events, suggesting a critical role in binding temporally adjacent events in long-term memory. Current results shed light onto the neural mechanisms that promote episodic encoding not only for information within the event, but also, importantly, in the ability to link across events to create a memory representation of continuous experience. Copyright © 2017 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Cacola, Priscila; Roberson, Jerroed; Gabbard, Carl
2013-01-01
Studies show that as we enter older adulthood (greater than 64 years), our ability to mentally represent action in the form of using motor imagery declines. Using a chronometry paradigm to compare the movement duration of imagined and executed movements, we tested young-, middle-aged, and older adults on their ability to perform sequential finger…
ERIC Educational Resources Information Center
Seiverling, Laura; Harclerode, Whitney; Williams, Keith
2014-01-01
The purpose of this study was to examine if sequential presentation with feeder modeling would lead to an increase in bites accepted of new foods compared to sequential presentation without feeder modeling in a typically developing 4-year-old boy with food selectivity. The participant's acceptance of novel foods increased both in the modeling and…
PETER, BEATE; BUTTON, LE; STOEL-GAMMON, CAROL; CHAPMAN, KATHY; RASKIND, WENDY H.
2013-01-01
The purpose of this study was to evaluate a global deficit in sequential processing as candidate endophenotypein a family with familial childhood apraxia of speech (CAS). Of 10 adults and 13 children in a three-generational family with speech sound disorder (SSD) consistent with CAS, 3 adults and 6 children had past or present SSD diagnoses. Two preschoolers with unremediated CAS showed a high number of sequencing errors during single-word production. Performance on tasks with high sequential processing loads differentiated between the affected and unaffected family members, whereas there were no group differences in tasks with low processing loads. Adults with a history of SSD produced more sequencing errors during nonword and multisyllabic real word imitation, compared to those without such a history. Results are consistent with a global deficit in sequential processing that influences speech development as well as cognitive and linguistic processing. PMID:23339324
Iterative non-sequential protein structural alignment.
Salem, Saeed; Zaki, Mohammed J; Bystroff, Christopher
2009-06-01
Structural similarity between proteins gives us insights into their evolutionary relationships when there is low sequence similarity. In this paper, we present a novel approach called SNAP for non-sequential pair-wise structural alignment. Starting from an initial alignment, our approach iterates over a two-step process consisting of a superposition step and an alignment step, until convergence. We propose a novel greedy algorithm to construct both sequential and non-sequential alignments. The quality of SNAP alignments were assessed by comparing against the manually curated reference alignments in the challenging SISY and RIPC datasets. Moreover, when applied to a dataset of 4410 protein pairs selected from the CATH database, SNAP produced longer alignments with lower rmsd than several state-of-the-art alignment methods. Classification of folds using SNAP alignments was both highly sensitive and highly selective. The SNAP software along with the datasets are available online at http://www.cs.rpi.edu/~zaki/software/SNAP.
Increasing efficiency of preclinical research by group sequential designs
Piper, Sophie K.; Rex, Andre; Florez-Vargas, Oscar; Karystianis, George; Schneider, Alice; Wellwood, Ian; Siegerink, Bob; Ioannidis, John P. A.; Kimmelman, Jonathan; Dirnagl, Ulrich
2017-01-01
Despite the potential benefits of sequential designs, studies evaluating treatments or experimental manipulations in preclinical experimental biomedicine almost exclusively use classical block designs. Our aim with this article is to bring the existing methodology of group sequential designs to the attention of researchers in the preclinical field and to clearly illustrate its potential utility. Group sequential designs can offer higher efficiency than traditional methods and are increasingly used in clinical trials. Using simulation of data, we demonstrate that group sequential designs have the potential to improve the efficiency of experimental studies, even when sample sizes are very small, as is currently prevalent in preclinical experimental biomedicine. When simulating data with a large effect size of d = 1 and a sample size of n = 18 per group, sequential frequentist analysis consumes in the long run only around 80% of the planned number of experimental units. In larger trials (n = 36 per group), additional stopping rules for futility lead to the saving of resources of up to 30% compared to block designs. We argue that these savings should be invested to increase sample sizes and hence power, since the currently underpowered experiments in preclinical biomedicine are a major threat to the value and predictiveness in this research domain. PMID:28282371
Iterative Self-Dual Reconstruction on Radar Image Recovery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martins, Charles; Medeiros, Fatima; Ushizima, Daniela
2010-05-21
Imaging systems as ultrasound, sonar, laser and synthetic aperture radar (SAR) are subjected to speckle noise during image acquisition. Before analyzing these images, it is often necessary to remove the speckle noise using filters. We combine properties of two mathematical morphology filters with speckle statistics to propose a signal-dependent noise filter to multiplicative noise. We describe a multiscale scheme that preserves sharp edges while it smooths homogeneous areas, by combining local statistics with two mathematical morphology filters: the alternating sequential and the self-dual reconstruction algorithms. The experimental results show that the proposed approach is less sensitive to varying window sizesmore » when applied to simulated and real SAR images in comparison with standard filters.« less
Han, Ba Leun; Choi, Hwan Jun
2014-03-01
Sequential flap coverage might be required for recurrent defects, but reusing a flap as a donor site has seldom been reported. The concept of a "free-style flap" has been developed, and it allows reconstructive surgeons to raise flaps with various designs reliably, even at sites of previous flap surgery. This article presents the concept of free-style recycling of a tensor fascia lata flap into a perforator-based flap separated in 2 planes in a patient with a recurrent bilateral trochanteric defect. If a reliable perforator is preserved and identified within the tissues by computed tomography angiography or a Doppler device, a new perforator flap can be designed and raised at the previous flap site.
Del Prato, Stefano; Rosenstock, Julio; Garcia-Sanchez, Ricardo; Iqbal, Nayyar; Hansen, Lars; Johnsson, Eva; Chen, Hungta; Mathieu, Chantal
2018-06-01
The safety of triple oral therapy with dapagliflozin plus saxagliptin plus metformin versus dual therapy with dapagliflozin or saxagliptin plus metformin was compared in a post-hoc analysis of 3 randomized trials of sequential or concomitant add-on of dapagliflozin and saxagliptin to metformin. In the concomitant add-on trial, patients with type 2 diabetes on stable metformin received dapagliflozin 10 mg/d plus saxagliptin 5 mg/d. In sequential add-on trials, patients on metformin plus either saxagliptin 5 mg/d or dapagliflozin 10 mg/d received dapagliflozin 10 mg/d or saxagliptin 5 mg/d, respectively, as add-on therapy. After 24 weeks, incidences of adverse events and serious adverse events were similar between triple and dual therapy and between concomitant and sequential add-on regimens. Urinary tract infections were more common with sequential than with concomitant add-on therapy; genital infections were reported only with sequential add-on of dapagliflozin to saxagliptin plus metformin. Hypoglycaemia incidence was <2.0% across all analysis groups. In conclusion, the safety and tolerability of triple therapy with dapagliflozin, saxagliptin and metformin, as either concomitant or sequential add-on, were similar to dual therapy with either agent added to metformin. © 2018 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.
Veiga, Helena Perrut; Bianchini, Esther Mandelbaum Gonçalves
2012-01-01
To perform an integrative review of studies on liquid sequential swallowing, by characterizing the methodology of the studies and the most important findings in young and elderly adults. Review of the literature written in English and Portuguese on PubMed, LILACS, SciELO and MEDLINE databases, within the past twenty years, available fully, using the following uniterms: sequential swallowing, swallowing, dysphagia, cup, straw, in various combinations. Research articles with a methodological approach on the characterization of liquid sequential swallowing by young and/or elderly adults, regardless of health condition, excluding studies involving only the esophageal phase. The following research indicators were applied: objectives, number and gender of participants; age group; amount of liquid offered; intake instruction; utensil used, methods and main findings. 18 studies met the established criteria. The articles were categorized according to the sample characterization and the methodology on volume intake, utensil used and types of exams. Most studies investigated only healthy individuals, with no swallowing complaints. Subjects were given different instructions as to the intake of all the volume: usual manner, continually, as rapidly as possible. The findings about the characterization of sequential swallowing were varied and described in accordance with the objectives of each study. It found great variability in the methodology employed to characterize the sequential swallowing. Some findings are not comparable, and sequential swallowing is not studied in most swallowing protocols, without consensus on the influence of the utensil.
Signorelli, Mauro; Lissoni, Andrea Alberto; De Ponti, Elena; Grassi, Tommaso; Ponti, Serena
2015-01-01
Objective Evaluation of the impact of sequential chemoradiotherapy in high risk endometrial cancer (EC). Methods Two hundred fifty-four women with stage IB grade 3, II and III EC (2009 FIGO staging), were included in this retrospective study. Results Stage I, II, and III was 24%, 28.7%, and 47.3%, respectively. Grade 3 tumor was 53.2% and 71.3% had deep myometrial invasion. One hundred sixty-five women (65%) underwent pelvic (+/- aortic) lymphadenectomy and 58 (22.8%) had nodal metastases. Ninety-eight women (38.6%) underwent radiotherapy, 59 (23.2%) chemotherapy, 42 (16.5%) sequential chemoradiotherapy, and 55 (21.7%) were only observed. After a median follow-up of 101 months, 78 women (30.7%) relapsed and 91 women (35.8%) died. Sequential chemoradiotherapy improved survival rates in women who did not undergo nodal evaluation (disease-free survival [DFS], p=0.040; overall survival [OS], p=0.024) or pelvic (+/- aortic) lymphadenectomy (DFS, p=0.008; OS, p=0.021). Sequential chemoradiotherapy improved both DFS (p=0.015) and OS (p=0.014) in stage III, while only a trend was found for DFS (p=0.210) and OS (p=0.102) in stage I-II EC. In the multivariate analysis, only age (≤65 years) and sequential chemoradiotherapy were statistically related to the prognosis. Conclusion Sequential chemoradiotherapy improves survival rates in high risk EC compared with chemotherapy or radiotherapy alone, in particular in stage III. PMID:26197768
[Bilateral cochlear implants in children: acquisition of binaural hearing].
Ramos-Macías, Angel; Deive-Maggiolo, Leopoldo; Artiles-Cabrera, Ovidio; González-Aguado, Rocío; Borkoski-Barreiro, Silvia A; Masgoret-Palau, Elizabeth; Falcón-González, Juan C; Bueno-Yanes, Jorge
2013-01-01
Several studies have indicated the benefit of bilateral cochlear implants in the acquisition of binaural hearing and bilateralism. In children with cochlear implants, is it possible to achieve binaurality after a second implant? When is the ideal time to implant them? The objective of this study was to analyse the binaural effect in children with bilateral implants and the differences between subjects with simultaneous and sequential implants with both short and long intervals. There were 90 patients between 1 and 2 years of age (the first surgery), implanted between 2000 and 2008. Of these, 25 were unilateral users and 65 bilateral; 17 patients had received simultaneous implants, 29 had sequential implants before 12 months after the first one (short interimplant period) and 19 after 12 months (long period). All of them were tested for silent and noisy verbal perception and a tonal threshold audiometry was performed. The silent perception test showed that the simultaneous and short period sequential implant patients (mean: 84.67%) versus unilateral and long period sequential implants (mean: 79.66%), had a statistically-significant difference (P=0,23). Likewise, the noisy perception test showed a difference with statistical significance (P=0,22) comparing the simultaneous implanted and short period sequential implants (mean, 77.17%) versus unilateral implanted and long period sequential ones (mean: 69.32%). The simultaneous and sequential short period implants acquired the advantages of binaural hearing. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Visual feature binding in younger and older adults: encoding and suffix interference effects.
Brown, Louise A; Niven, Elaine H; Logie, Robert H; Rhodes, Stephen; Allen, Richard J
2017-02-01
Three experiments investigated younger (18-25 yrs) and older (70-88 yrs) adults' temporary memory for colour-shape combinations (binding). We focused upon estimating the magnitude of the binding cost for each age group across encoding time (Experiment 1; 900/1500 ms), presentation format (Experiment 2; simultaneous/sequential), and interference (Experiment 3; control/suffix) conditions. In Experiment 1, encoding time did not differentially influence binding in the two age groups. In Experiment 2, younger adults exhibited poorer binding performance with sequential relative to simultaneous presentation, and serial position analyses highlighted a particular age-related difficulty remembering the middle item of a series (for all memory conditions). Experiments 1-3 demonstrated small to medium binding effect sizes in older adults across all encoding conditions, with binding less accurate than shape memory. However, younger adults also displayed negative effects of binding (small to large) in two of the experiments. Even when older adults exhibited a greater suffix interference effect in Experiment 3, this was for all memory types, not just binding. We therefore conclude that there is no consistent evidence for a visual binding deficit in healthy older adults. This relative preservation contrasts with the specific and substantial deficits in visual feature binding found in several recent studies of Alzheimer's disease.
Decroocq, Justine; Itzykson, Raphaël; Vigouroux, Stéphane; Michallet, Mauricette; Yakoub-Agha, Ibrahim; Huynh, Anne; Beckerich, Florence; Suarez, Felipe; Chevallier, Patrice; Nguyen-Quoc, Stéphanie; Ledoux, Marie-Pierre; Clement, Laurence; Hicheri, Yosr; Guillerm, Gaëlle; Cornillon, Jérôme; Contentin, Nathalie; Carre, Martin; Maillard, Natacha; Mercier, Mélanie; Mohty, Mohamad; Beguin, Yves; Bourhis, Jean-Henri; Charbonnier, Amandine; Dauriac, Charles; Bay, Jacques-Olivier; Blaise, Didier; Deconinck, Eric; Jubert, Charlotte; Raus, Nicole; Peffault de Latour, Regis; Dhedin, Nathalie
2018-03-01
Patients with acute myeloid leukemia (AML) in relapse or refractory to induction therapy have a dismal prognosis. Allogeneic hematopoietic stem cell transplantation is the only curative option. In these patients, we aimed to compare the results of a myeloablative transplant versus a sequential approach consisting in a cytoreductive chemotherapy followed by a reduced intensity conditioning regimen and prophylactic donor lymphocytes infusions. We retrospectively analyzed 99 patients aged 18-50 years, transplanted for a refractory (52%) or a relapsed AML not in remission (48%). Fifty-eight patients received a sequential approach and 41 patients a myeloablative conditioning regimen. Only 6 patients received prophylactic donor lymphocytes infusions. With a median follow-up of 48 months, 2-year overall survival was 39%, 95% confidence interval (CI) (24-53) in the myeloablative group versus 33%, 95% CI (21-45) in the sequential groups (P = .39), and 2-year cumulative incidence of relapse (CIR) was 57% versus 50% respectively (P = .99). Nonrelapse mortality was not higher in the myeloablative group (17% versus 15%, P = .44). In multivariate analysis, overall survival, CIR and nonrelapse mortality remained similar between the two groups. However, in multivariate analysis, sequential conditioning led to fewer acute grade II-IV graft versus host disease (GVHD) (HR for sequential approach = 0.37; 95% CI: 0.21-0.65; P < .001) without a significant impact on chronic GVHD (all grades and extensive). In young patients with refractory or relapsed AML, myeloablative transplant and sequential approach offer similar outcomes except for a lower incidence of acute GvHD after a sequential transplant. © 2018 Wiley Periodicals, Inc.
A comparison of sequential and spiral scanning techniques in brain CT.
Pace, Ivana; Zarb, Francis
2015-01-01
To evaluate and compare image quality and radiation dose of sequential computed tomography (CT) examinations of the brain and spiral CT examinations of the brain imaged on a GE HiSpeed NX/I Dual Slice 2CT scanner. A random sample of 40 patients referred for CT examination of the brain was selected and divided into 2 groups. Half of the patients were scanned using the sequential technique; the other half were scanned using the spiral technique. Radiation dose data—both the computed tomography dose index (CTDI) and the dose length product (DLP)—were recorded on a checklist at the end of each examination. Using the European Guidelines on Quality Criteria for Computed Tomography, 4 radiologists conducted a visual grading analysis and rated the level of visibility of 6 anatomical structures considered necessary to produce images of high quality. The mean CTDI(vol) and DLP values were statistically significantly higher (P <.05) with the sequential scans (CTDI(vol): 22.06 mGy; DLP: 304.60 mGy • cm) than with the spiral scans (CTDI(vol): 14.94 mGy; DLP: 229.10 mGy • cm). The mean image quality rating scores for all criteria of the sequential scanning technique were statistically significantly higher (P <.05) in the visual grading analysis than those of the spiral scanning technique. In this local study, the sequential technique was preferred over the spiral technique for both overall image quality and differentiation between gray and white matter in brain CT scans. Other similar studies counter this finding. The radiation dose seen with the sequential CT scanning technique was significantly higher than that seen with the spiral CT scanning technique. However, image quality with the sequential technique was statistically significantly superior (P <.05).
Random sequential adsorption of cubes
NASA Astrophysics Data System (ADS)
Cieśla, Michał; Kubala, Piotr
2018-01-01
Random packings built of cubes are studied numerically using a random sequential adsorption algorithm. To compare the obtained results with previous reports, three different models of cube orientation sampling were used. Also, three different cube-cube intersection algorithms were tested to find the most efficient one. The study focuses on the mean saturated packing fraction as well as kinetics of packing growth. Microstructural properties of packings were analyzed using density autocorrelation function.
ERIC Educational Resources Information Center
Grilo, Carlos M.; Masheb, Robin M.; Wilson, G. Terence; Gueorguieva, Ralitza; White, Marney A.
2011-01-01
Objective: Cognitive-behavioral therapy (CBT) is the best established treatment for binge-eating disorder (BED) but does not produce weight loss. The efficacy of behavioral weight loss (BWL) in obese patients with BED is uncertain. This study compared CBT, BWL, and a sequential approach in which CBT is delivered first, followed by BWL (CBT + BWL).…
TDRSS-user orbit determination using batch least-squares and sequential methods
NASA Astrophysics Data System (ADS)
Oza, D. H.; Jones, T. L.; Hakimi, M.; Samii, Mina V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.
1993-02-01
The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), and operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were less than 40 meters after the filter had reached steady state.
Fan, Tingbo; Liu, Zhenbo; Zhang, Dong; Tang, Mengxing
2013-03-01
Lesion formation and temperature distribution induced by high-intensity focused ultrasound (HIFU) were investigated both numerically and experimentally via two energy-delivering strategies, i.e., sequential discrete and continuous scanning modes. Simulations were presented based on the combination of Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation and bioheat equation. Measurements were performed on tissue-mimicking phantoms sonicated by a 1.12-MHz single-element focused transducer working at an acoustic power of 75 W. Both the simulated and experimental results show that, in the sequential discrete mode, obvious saw-tooth-like contours could be observed for the peak temperature distribution and the lesion boundaries, with the increasing interval space between two adjacent exposure points. In the continuous scanning mode, more uniform peak temperature distributions and lesion boundaries would be produced, and the peak temperature values would decrease significantly with the increasing scanning speed. In addition, compared to the sequential discrete mode, the continuous scanning mode could achieve higher treatment efficiency (lesion area generated per second) with a lower peak temperature. The present studies suggest that the peak temperature and tissue lesion resulting from the HIFU exposure could be controlled by adjusting the transducer scanning speed, which is important for improving the HIFU treatment efficiency.
TDRSS-user orbit determination using batch least-squares and sequential methods
NASA Technical Reports Server (NTRS)
Oza, D. H.; Jones, T. L.; Hakimi, M.; Samii, Mina V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.
1993-01-01
The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), and operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were less than 40 meters after the filter had reached steady state.
Op den Dries, Sanna; Karimian, Negin; Westerkamp, Andrie C; Sutton, Michael E; Kuipers, Michiel; Wiersema-Buist, Janneke; Ottens, Petra J; Kuipers, Jeroen; Giepmans, Ben N; Leuvenink, Henri G D; Lisman, Ton; Porte, Robert J
2016-07-01
Bile duct injury may occur during liver procurement and transplantation, especially in livers from donation after circulatory death (DCD) donors. Normothermic machine perfusion (NMP) has been shown to reduce hepatic injury compared to static cold storage (SCS). However, it is unknown whether NMP provides better preservation of bile ducts. The aim of this study was to determine the impact of NMP on bile duct preservation in both DCD and non-DCD livers. DCD and non-DCD livers obtained from Lewis rats were preserved for 3 hours using either SCS or NMP, followed by 2 hours ex vivo reperfusion. Biomarkers of bile duct injury (gamma-glutamyltransferase and lactate dehydrogenase in bile) were lower in NMP-preserved livers compared to SCS-preserved livers. Biliary bicarbonate concentration, reflecting biliary epithelial function, was 2-fold higher in NMP-preserved livers (P < 0.01). In parallel with this, the pH of the bile was significantly higher in NMP-preserved livers (7.63 ± 0.02 and 7.74 ± 0.05 for non-DCD and DCD livers, respectively) compared with SCS-preserved livers (7.46 ± 0.02 and 7.49 ± 0.04 for non-DCD and DCD livers, respectively). Scanning and transmission electron microscopy of donor extrahepatic bile ducts demonstrated significantly decreased injury of the biliary epithelium of NMP-preserved donor livers (including the loss of lateral interdigitations and mitochondrial injury). Differences between NMP and SCS were most prominent in DCD livers. Compared to conventional SCS, NMP provides superior preservation of bile duct epithelial cell function and morphology, especially in DCD donor livers. By reducing biliary injury, NMP could have an important impact on the utilization of DCD livers and outcome after transplantation. Liver Transplantation 22 994-1005 2016 AASLD. © 2016 American Association for the Study of Liver Diseases.
Lovelock, D F; Deak, T
2017-09-01
A wide range of stress-related pathologies such as post-traumatic stress disorder are considered to arise from aberrant or maladaptive forms of stress adaptation. The hypothalamic-pituitary-adrenal (HPA) axis readily adapts to repeated stressor exposure, yet little is known about adaptation in neuroimmune responses to repeated or sequential stress challenges. In Experiment 1, rats were exposed to 10 days of restraint alone (60 minutes daily), forced swim alone (30 minutes daily) or daily sequential exposure to restraint (60 minutes) followed immediately by forced swim (30 minutes), termed sequential stress exposure. Habituation of the corticosterone (CORT) response occurred to restraint by 5 days and swim at 10 days, whereas rats exposed to sequential stress exposure failed to display habituation to the combined challenge. Experiment 2 compared 1 or 5 days of forced swim with sequential stress exposure and examined how each affected expression of several neuroimmune and cellular activation genes in the paraventricular nucleus of the hypothalamus (PVN), prefrontal cortex (PFC) and hippocampus (HPC). Sequential exposure to restraint and swim increased interleukin (IL)-1β in the PVN, an effect that was attenuated after 5 days. Sequential stress exposure also elicited IL-6 and tumour necrosis factor-α responses in the HPC and PFC, respectively, which did not habituate after 5 days. Experiment 3 tested whether prior habituation to restraint (5 days) would alter the IL-1β response evoked by swim exposure imposed immediately after the sixth day of restraint. Surprisingly, a history of repeated exposure to restraint attenuated the PVN IL-1β response after swim in comparison to acutely-exposed subjects despite an equivalent CORT response. Overall, these findings suggest that habituation of neuroimmune responses to stress proceeds: (i) independent of HPA axis habituation; (ii) likely requires more daily sessions of stress to develop; and (iii) IL-1β displays a greater tendency to habituate after repeated stress challenges compared to other stress-reactive cytokines. © 2017 British Society for Neuroendocrinology.
Parallelization of a Fully-Distributed Hydrologic Model using Sub-basin Partitioning
NASA Astrophysics Data System (ADS)
Vivoni, E. R.; Mniszewski, S.; Fasel, P.; Springer, E.; Ivanov, V. Y.; Bras, R. L.
2005-12-01
A primary obstacle towards advances in watershed simulations has been the limited computational capacity available to most models. The growing trend of model complexity, data availability and physical representation has not been matched by adequate developments in computational efficiency. This situation has created a serious bottleneck which limits existing distributed hydrologic models to small domains and short simulations. In this study, we present novel developments in the parallelization of a fully-distributed hydrologic model. Our work is based on the TIN-based Real-time Integrated Basin Simulator (tRIBS), which provides continuous hydrologic simulation using a multiple resolution representation of complex terrain based on a triangulated irregular network (TIN). While the use of TINs reduces computational demand, the sequential version of the model is currently limited over large basins (>10,000 km2) and long simulation periods (>1 year). To address this, a parallel MPI-based version of the tRIBS model has been implemented and tested using high performance computing resources at Los Alamos National Laboratory. Our approach utilizes domain decomposition based on sub-basin partitioning of the watershed. A stream reach graph based on the channel network structure is used to guide the sub-basin partitioning. Individual sub-basins or sub-graphs of sub-basins are assigned to separate processors to carry out internal hydrologic computations (e.g. rainfall-runoff transformation). Routed streamflow from each sub-basin forms the major hydrologic data exchange along the stream reach graph. Individual sub-basins also share subsurface hydrologic fluxes across adjacent boundaries. We demonstrate how the sub-basin partitioning provides computational feasibility and efficiency for a set of test watersheds in northeastern Oklahoma. We compare the performance of the sequential and parallelized versions to highlight the efficiency gained as the number of processors increases. We also discuss how the coupled use of TINs and parallel processing can lead to feasible long-term simulations in regional watersheds while preserving basin properties at high-resolution.
Custodiol for myocardial protection and preservation: a systematic review
Seco, Michael; Dunne, Ben; Matzelle, Shannon J.; Murphy, Michelle; Joshi, Pragnesh; Yan, Tristan D.; Wilson, Michael K.; Bannon, Paul G.; Vallely, Michael P.; Passage, Jurgen
2013-01-01
Introduction Custodiol cardioplegia is attractive for minimally invasive cardiac surgery, as a single dose provides a long period of myocardial protection. Despite widespread use in Europe, there is little data confirming its efficacy compared with conventional (blood or crystalloid) cardioplegia. There is similar enthusiasm for its use in organ preservation for transplant, but also a lack of data. This systematic review aimed to assess the evidence for the efficacy of Custodiol in myocardial protection and as a preservation solution in heart transplant. Methods Electronic searches were performed of six databases from inception to October 2013. Reviewers independently identified studies that compared Custodiol with conventional cardioplegia (blood or extracellular crystalloid) in adult patients for meta-analysis; large case series that reported results using Custodiol were analyzed. Next, we identified studies that compared Custodiol with other organ preservation solutions for organ preservation in heart transplant. Results Fourteen studies compared Custodiol with conventional cardioplegia for myocardial protection in adult cardiac surgery. No difference was identified in mortality; there was a trend for increased incidence of ventricular fibrillation in the Custodiol group that did not reach statistical significance. No difference was identified in studies that compared Custodiol with other solutions for heart transplant. Conclusions Despite widespread clinical use, the evidence supporting the superiority of Custodiol over other solutions for myocardial protection or organ preservation is limited. Large randomised trials are required. PMID:24349972
EEG Classification with a Sequential Decision-Making Method in Motor Imagery BCI.
Liu, Rong; Wang, Yongxuan; Newman, Geoffrey I; Thakor, Nitish V; Ying, Sarah
2017-12-01
To develop subject-specific classifier to recognize mental states fast and reliably is an important issue in brain-computer interfaces (BCI), particularly in practical real-time applications such as wheelchair or neuroprosthetic control. In this paper, a sequential decision-making strategy is explored in conjunction with an optimal wavelet analysis for EEG classification. The subject-specific wavelet parameters based on a grid-search method were first developed to determine evidence accumulative curve for the sequential classifier. Then we proposed a new method to set the two constrained thresholds in the sequential probability ratio test (SPRT) based on the cumulative curve and a desired expected stopping time. As a result, it balanced the decision time of each class, and we term it balanced threshold SPRT (BTSPRT). The properties of the method were illustrated on 14 subjects' recordings from offline and online tests. Results showed the average maximum accuracy of the proposed method to be 83.4% and the average decision time of 2.77[Formula: see text]s, when compared with 79.2% accuracy and a decision time of 3.01[Formula: see text]s for the sequential Bayesian (SB) method. The BTSPRT method not only improves the classification accuracy and decision speed comparing with the other nonsequential or SB methods, but also provides an explicit relationship between stopping time, thresholds and error, which is important for balancing the speed-accuracy tradeoff. These results suggest that BTSPRT would be useful in explicitly adjusting the tradeoff between rapid decision-making and error-free device control.
Cost-effectiveness of allopurinol and febuxostat for the management of gout.
Jutkowitz, Eric; Choi, Hyon K; Pizzi, Laura T; Kuntz, Karen M
2014-11-04
Gout is the most common inflammatory arthritis in the United States. To evaluate the cost-effectiveness of urate-lowering treatment strategies for the management of gout. Markov model. Published literature and expert opinion. Patients for whom allopurinol or febuxostat is a suitable initial urate-lowering treatment. Lifetime. Health care payer. 5 urate-lowering treatment strategies were evaluated: no treatment; allopurinol- or febuxostat-only therapy; allopurinol-febuxostat sequential therapy; and febuxostat-allopurinol sequential therapy. Two dosing scenarios were investigated: fixed dose (80 mg of febuxostat daily, 0.80 success rate; 300 mg of allopurinol daily, 0.39 success rate) and dose escalation (≤120 mg of febuxostat daily, 0.82 success rate; ≤800 mg of allopurinol daily, 0.78 success rate). Discounted costs, discounted quality-adjusted life-years, and incremental cost-effectiveness ratios. In both dosing scenarios, allopurinol-only therapy was cost-saving. Dose-escalation allopurinol-febuxostat sequential therapy was more costly but more effective than dose-escalation allopurinol therapy, with an incremental cost-effectiveness ratio of $39 400 per quality-adjusted life-year. The relative rankings of treatments did not change. Our results were relatively sensitive to several potential variations of model assumptions; however, the cost-effectiveness ratios of dose escalation with allopurinol-febuxostat sequential therapy remained lower than the willingness-to-pay threshold of $109 000 per quality-adjusted life-year. Long-term outcome data for patients with gout, including medication adherence, are limited. Allopurinol single therapy is cost-saving compared with no treatment. Dose-escalation allopurinol-febuxostat sequential therapy is cost-effective compared with accepted willingness-to-pay thresholds. Agency for Healthcare Research and Quality.
Fonoff, Erich Talamoni; Azevedo, Angelo; Angelos, Jairo Silva Dos; Martinez, Raquel Chacon Ruiz; Navarro, Jessie; Reis, Paul Rodrigo; Sepulveda, Miguel Ernesto San Martin; Cury, Rubens Gisbert; Ghilardi, Maria Gabriela Dos Santos; Teixeira, Manoel Jacobsen; Lopez, William Omar Contreras
2016-07-01
OBJECT Currently, bilateral procedures involve 2 sequential implants in each of the hemispheres. The present report demonstrates the feasibility of simultaneous bilateral procedures during the implantation of deep brain stimulation (DBS) leads. METHODS Fifty-seven patients with movement disorders underwent bilateral DBS implantation in the same study period. The authors compared the time required for the surgical implantation of deep brain electrodes in 2 randomly assigned groups. One group of 28 patients underwent traditional sequential electrode implantation, and the other 29 patients underwent simultaneous bilateral implantation. Clinical outcomes of the patients with Parkinson's disease (PD) who had undergone DBS implantation of the subthalamic nucleus using either of the 2 techniques were compared. RESULTS Overall, a reduction of 38.51% in total operating time for the simultaneous bilateral group (136.4 ± 20.93 minutes) as compared with that for the traditional consecutive approach (220.3 ± 27.58 minutes) was observed. Regarding clinical outcomes in the PD patients who underwent subthalamic nucleus DBS implantation, comparing the preoperative off-medication condition with the off-medication/on-stimulation condition 1 year after the surgery in both procedure groups, there was a mean 47.8% ± 9.5% improvement in the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III) score in the simultaneous group, while the sequential group experienced 47.5% ± 15.8% improvement (p = 0.96). Moreover, a marked reduction in the levodopa-equivalent dose from preoperatively to postoperatively was similar in these 2 groups. The simultaneous bilateral procedure presented major advantages over the traditional sequential approach, with a shorter total operating time. CONCLUSIONS A simultaneous stereotactic approach significantly reduces the operation time in bilateral DBS procedures, resulting in decreased microrecording time, contributing to the optimization of functional stereotactic procedures.
Olusesi, A D; Oyeniran, O
2017-05-01
Few studies have compared bilateral same-day with staged tympanoplasty using cartilage graft materials. A prospective randomised observational study was performed of 38 chronic suppurative otitis media patients (76 ears) who were assigned to undergo bilateral sequential same-day tympanoplasty (18 patients, 36 ears) or bilateral sequential tympanoplasty performed 3 months apart (20 patients, 40 ears). Disease duration, intra-operative findings, combined duration of surgery, post-operative graft appearance at 6 weeks, post-operative complications, re-do rate and relative cost of surgery were recorded. Tympanic membrane perforations were predominantly subtotal (p = 0.36, odds ratio = 0.75). Most grafts were harvested from the conchal cartilage and fewer from the tragus (p = 0.59, odds ratio = 1.016). Types of complication, post-operative hearing gain and revision rates were similar in both patient groups. Surgical outcomes are not significantly different for same-day and bilateral cartilage tympanoplasty, but same-day surgery has the added benefit of a lower cost.
Perceptual Grouping Affects Pitch Judgments Across Time and Frequency
Borchert, Elizabeth M. O.; Micheyl, Christophe; Oxenham, Andrew J.
2010-01-01
Pitch, the perceptual correlate of fundamental frequency (F0), plays an important role in speech, music and animal vocalizations. Changes in F0 over time help define musical melodies and speech prosody, while comparisons of simultaneous F0 are important for musical harmony, and for segregating competing sound sources. This study compared listeners’ ability to detect differences in F0 between pairs of sequential or simultaneous tones that were filtered into separate, non-overlapping spectral regions. The timbre differences induced by filtering led to poor F0 discrimination in the sequential, but not the simultaneous, conditions. Temporal overlap of the two tones was not sufficient to produce good performance; instead performance appeared to depend on the two tones being integrated into the same perceptual object. The results confirm the difficulty of comparing the pitches of sequential sounds with different timbres and suggest that, for simultaneous sounds, pitch differences may be detected through a decrease in perceptual fusion rather than an explicit coding and comparison of the underlying F0s. PMID:21077719
Phosphorus cycling in the Early Aptian
NASA Astrophysics Data System (ADS)
Oakes, R.; Dittrich, M.; Wortmann, U. G.
2012-12-01
Phosphorus is an essential nutrient for living organisms. It is vital for the formation of ATP, the energy store in cells, and is needed for DNA synthesis. Seawater phosphorus concentration therefore plays a critical role in controlling marine productivity on geological timescales. The majority of research on the P cycle focuses on modern lacustrine and marine settings. This follows the necessity to gain a further understanding on the effects of agricultural fertilisers on nutrient cycling; in particular on the mechanisms which lead to eutrophication. These studies use sequential extraction to determine the speciation of P. The results suggest that bottom sediments can act as both a source and a sink of phosphorus; the role they assume depends on range of factors including bottom water oxygen concentrations, sedimentation rate and the concentration of iron. This study applies a sequential extraction method developed in modern sediments to sediments from the Early Cretaceous, specifically the Early Aptian. During this time, globally synchronous oceanic anoxic events (OAE's) appear in the rock record. It has been suggested that these events represent an increase in marine productivity combined with bottom water anoxia. Our study investigates whether the speciation of sedimentary phosphorus can be used to reconstruct P cycling at this time. Our samples are taken from pre-, syn- and post-OAE1a but are not from the organic matter rich layers. Our results show that the original fractions of phosphorus have been altered during diagenesis with the majority of phosphorus now being preserved as either apatite (Ca-P) or phosphorus in organic matter (Porg). The dominance of Ca-P is expected as it is thought that redox-sensitive forms of P undergo 'sink switching' during diagenesis and are preserved as Ca-P. The high concentration of Porg however, differs from previous studies which generally find that Ca-P or iron (oxyhydr)oxide associated phosphorus (Fe-P) are dominant depending on deposition conditions. We find that during the anoxic event Ca-P preservation is enhanced, a trend which is not mirrored by an increase in total phosphorus concentration. This suggests that the formation of authigenic apatite via sink switching may have been enhanced during OAE1a. This agrees with the findings of a modern field and lab based study which proposes that more P is fixed than regenerated under anoxic conditions but contradicts earlier studies which suggest that more P will be refluxed from sediments under anoxic bottom-water conditions.
Chen, Qi-Fen; Zhang, Yi-Wei
2018-02-01
To investigate the clinical effect of Saccharomyces boulardii powder combined with azithromycin sequential therapy in the treatment of children with diarrhea secondary to Mycoplasma pneumoniae pneumonia. A total of 88 children with diarrhea secondary to Mycoplasma pneumoniae pneumonia between June 2015 and March 2017 were divided into control group and study group using a random number table, with 44 children in each group. The children in the control group were given routine treatment combined with azithromycin sequential therapy, and those in the study group were given oral Saccharomyces boulardii powder in addition to the treatment in the control group until the end of azithromycin sequential therapy. After the treatment ended, the two groups were compared in terms of time to improvement of clinical symptoms, length of hospital stay, clinical outcome, defecation frequency before and after treatment, condition of intestinal dysbacteriosis, and incidence of adverse events. Compared with the control group, the study group had significantly shorter time to improvement of clinical symptoms and length of hospital stay (P<0.05). The study group had a significantly higher response rate than the control group (P<0.05). On days 3 and 5 of treatment, the study group had a significant reduction in defecation frequency compared with the control group (P<0.05). The study group had a significantly lower rate of intestinal dysbacteriosis than the control group (P<0.05). There was no significant difference in the incidence of adverse events between the two groups (P>0.05). In the treatment of children with diarrhea secondary to Mycoplasma pneumoniae pneumonia, Saccharomyces boulardii powder combined with azithromycin sequential therapy can improve clinical symptoms, shorten the length of hospital stay, reduce defecation frequency and the incidence of intestinal dysbacteriosis, and improve clinical outcomes, and does not increase the risk of adverse events.
Active and Inactive Leg Hemodynamics during Sequential Single-Leg Interval Cycling.
Gordon, Nicole; Abbiss, Chris R; Ihsan, Mohammed; Maiorana, Andrew J; Peiffer, Jeremiah J
2018-06-01
Leg order during sequential single-leg cycling (i.e., exercising both legs independently within a single session) may affect local muscular responses potentially influencing adaptations. This study examined the cardiovascular and skeletal muscle hemodynamic responses during double-leg and sequential single-leg cycling. Ten young healthy adults (28 ± 6 yr) completed six 1-min double-leg intervals interspersed with 1 min of passive recovery and, on a separate occasion, 12 (six with one leg followed by six with the other leg) 1-min single-leg intervals interspersed with 1 min of passive recovery. Oxygen consumption, heart rate, blood pressure, muscle oxygenation, muscle blood volume, and power output were measured throughout each session. Oxygen consumption, heart rate, and power output were not different between sets of single-leg intervals, but the average of both sets was lower than the double-leg intervals. Mean arterial pressure was higher during double-leg compared with sequential single-leg intervals (115 ± 9 vs 104 ± 9 mm Hg, P < 0.05) and higher during the initial compared with second set of single-leg intervals (108 ± 10 vs 101 ± 10 mm Hg, P < 0.05). The increase in muscle blood volume from baseline was similar between the active single leg and the double leg (267 ± 150 vs 214 ± 169 μM·cm, P = 0.26). The pattern of change in muscle blood volume from the initial to second set of intervals was significantly different (P < 0.05) when the leg was active in the initial (-52.3% ± 111.6%) compared with second set (65.1% ± 152.9%). These data indicate that the order in which each leg performs sequential single-leg cycling influences the local hemodynamic responses, with the inactive muscle influencing the stimulus experienced by the contralateral leg.
Comparison of contamination rates between preserved and preservative-free fluoroquinolone eyedrops.
Kim, Mo Sae; Kim, Hong Kyun; Kim, Joon Mo; Choi, Chul Young
2013-03-01
To evaluate the antimicrobial effectiveness of preservative-free fluoroquinolone products compared with benzalkonium chloride containing fluoroquinolones using the challenge test provided by the United States Pharmacopeia (USP) and the in-use test. 1. Challenge test: to compare the growth of microorganisms between different fluoroquinolone preparations, four test organisms, including Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, and Aspergillus niger were chosen among five microorganisms listed by USP 2004. The inoculated products were sampled for microbial survivors at days 7, 14, and 28 following initial inoculation at room temperature. The number of surviving organisms were calculated as a Log10 reduction from the original inocula. 2. In-use test: a total of 100 bottles were collected after instillation of preservative-free fluoroquinolone eyedrops in volunteer patients after 1 week of use. The remaining fluid and tips of the bottles were cultured. Colonies on the plates were counted at the end of the incubation period. All microorganisms were identified by Gram staining and biochemical assays. 1. Challenge test: preservative-free gatifloxacin and levofloxacin demonstrated a lower log reduction against A. niger than preserved fluoroquinolones and preservative-free moxifloxacin at all time points. 2. In-use test: There was no contamination identified on plates inoculated by preservative-free quinolone bottles after 1 week of use in this study. Physicians should be aware of the lower antifungal preservative effectiveness of some preservative-free fluoroquinolone preparations than preserved ones.
Dinavahi, Saketh S; Noory, Mohammad A; Gowda, Raghavendra; Drabick, Joseph J; Berg, Arthur; Neves, Rogerio I; Robertson, Gavin P
2018-03-01
Drug combinations acting synergistically to kill cancer cells have become increasingly important in melanoma as an approach to manage the recurrent resistant disease. Protein kinase B (AKT) is a major target in this disease but its inhibitors are not effective clinically, which is a major concern. Targeting AKT in combination with WEE1 (mitotic inhibitor kinase) seems to have potential to make AKT-based therapeutics effective clinically. Since agents targeting AKT and WEE1 have been tested individually in the clinic, the quickest way to move the drug combination to patients would be to combine these agents sequentially, enabling the use of existing phase I clinical trial toxicity data. Therefore, a rapid preclinical approach is needed to evaluate whether simultaneous or sequential drug treatment has maximal therapeutic efficacy, which is based on a mechanistic rationale. To develop this approach, melanoma cell lines were treated with AKT inhibitor AZD5363 [4-amino- N -[(1 S )-1-(4-chlorophenyl)-3-hydroxypropyl]-1-(7 H -pyrrolo[2,3- d ]pyrimidin-4-yl)piperidine-4-carboxamide] and WEE1 inhibitor AZD1775 [2-allyl-1-(6-(2-hydroxypropan-2-yl)pyridin-2-yl)-6-((4-(4-methylpiperazin-1-yl)phenyl)amino)-1 H -pyrazolo[3,4- d ]pyrimidin-3(2 H )-one] using simultaneous and sequential dosing schedules. Simultaneous treatment synergistically reduced melanoma cell survival and tumor growth. In contrast, sequential treatment was antagonistic and had a minimal tumor inhibitory effect compared with individual agents. Mechanistically, simultaneous targeting of AKT and WEE1 enhanced deregulation of the cell cycle and DNA damage repair pathways by modulating transcription factors p53 and forkhead box M1, which was not observed with sequential treatment. Thus, this study identifies a rapid approach to assess the drug combinations with a mechanistic basis for selection, which suggests that combining AKT and WEE1 inhibitors is needed for maximal efficacy. Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics.
Schecter, Arnold; Colacino, Justin A; Shah, Nirav; Harris, T Robert; Papke, Olaf
2009-01-01
For analysis of organochlorine contaminants in human tissue, the "gold standard" for preservation, storage, and shipping is usually freezing. However, this method can be difficult, if samples are taken in remote areas, and costly, when the samples must be shipped on dry ice. Therefore, a more simple and cost effective method of preservation is essential for remote field work. Potassium dichromate (K(2)Cr(2)O(7)) has been successfully employed in the preservation of human and cows' milk as well as chicken eggs. Our previous studies described the use of potassium dichromate for preservation of whole blood for analysis of dioxins, dibenzofurans, and PCBs. Potassium dichromate was found to successfully preserve blood at room temperature for 34 d with no significant differences in the measured concentrations of chemical contaminants or blood lipid level when compared to frozen samples. However, in a follow-up study, 3 months and 6 months of potassium dichromate preservation proved inadequate to preserve the samples for organic pollutant analysis. We noted that the lipid portion of the blood in the chemically preserved samples was declining in level or degrading, while the persistent organic pollutants remained intact at the same levels on a whole weight basis. To narrow down the window of efficacy for the use of potassium dichromate to preserve blood samples for analysis, the present study compared chemical preservation to freezing for an intermediate time period, 2 months. Similar to our previous findings at 3 and 6 months, at 2 months significant lipid degradation was observed in the chemically preserved samples. Chemically preserved samples had significantly higher levels of organochlorine contaminants (dioxins, dibenzofurans, and PCBs) when measured on a blood lipid basis but not on a wet weight basis compared to frozen samples. While 2 months of potassium dichromate preservation was not useful for obtaining accurate measure of dioxins, furans, and PCBs on a lipid basis, previous studies found this method of preservation to be useful for at least one month (Schecter, A., Pavuk, M., Päpke, O., Malisch, R., 2004. The use of potassium dichromate and ethyl alcohol as blood preservatives for analysis of organochlorine contaminants. Chemosphere 57, 1-7). However blood stored at -70 degrees C and at 22 degrees C with potassium dichromate gave similar results when expressed on a wet weight basis.
Sewsynker-Sukai, Yeshona; Gueguim Kana, E B
2017-11-01
This study presents a sequential sodium phosphate dodecahydrate (Na 3 PO 4 ·12H 2 O) and zinc chloride (ZnCl 2 ) pretreatment to enhance delignification and enzymatic saccharification of corn cobs. The effects of process parameters of Na 3 PO 4 ·12H 2 O concentration (5-15%), ZnCl 2 concentration (1-5%) and solid to liquid ratio (5-15%) on reducing sugar yield from corn cobs were investigated. The sequential pretreatment model was developed and optimized with a high coefficient of determination value (0.94). Maximum reducing sugar yield of 1.10±0.01g/g was obtained with 14.02% Na 3 PO 4 ·12H 2 O, 3.65% ZnCl 2 and 5% solid to liquid ratio. Scanning electron microscopy (SEM) and Fourier Transform Infrared analysis (FTIR) showed major lignocellulosic structural changes after the optimized sequential pretreatment with 63.61% delignification. In addition, a 10-fold increase in the sugar yield was observed compared to previous reports on the same substrate. This sequential pretreatment strategy was efficient for enhancing enzymatic saccharification of corn cobs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Costa, Marilia G; Barbosa, José C; Yamamoto, Pedro T
2007-01-01
The sequential sampling is characterized by using samples of variable sizes, and has the advantage of reducing sampling time and costs if compared to fixed-size sampling. To introduce an adequate management for orthezia, sequential sampling plans were developed for orchards under low and high infestation. Data were collected in Matão, SP, in commercial stands of the orange variety 'Pêra Rio', at five, nine and 15 years of age. Twenty samplings were performed in the whole area of each stand by observing the presence or absence of scales on plants, being plots comprised of ten plants. After observing that in all of the three stands the scale population was distributed according to the contagious model, fitting the Negative Binomial Distribution in most samplings, two sequential sampling plans were constructed according to the Sequential Likelihood Ratio Test (SLRT). To construct these plans an economic threshold of 2% was adopted and the type I and II error probabilities were fixed in alpha = beta = 0.10. Results showed that the maximum numbers of samples expected to determine control need were 172 and 76 samples for stands with low and high infestation, respectively.
Lavie, Limor; Banai, Karen; Attias, Joseph; Karni, Avi
2014-03-01
The purpose of this study was to determine the effects of sequential versus simultaneous bilateral hearing aids fitting on patient compliance. Thirty-six older adults with hearing impairment participated in this study. Twelve were fitted with bilateral hearing aids simultaneously. The remaining participants were fitted sequentially: One hearing aid (to the left or to the right ear) was used initially; 1 month later, the other ear was also fitted with a hearing aid for bilateral use. Self-reports on usefulness and compliance were elicited after the first and second months of hearing aid use. In addition, the number of hours the hearing aids were used was extracted from the data loggings of each device. Simultaneous fitting resulted in high levels of compliance and consistent usage throughout the study period. Sequential fitting resulted in abrupt reduction in compliance and hours of use once the second hearing aid was added, both in the clinical scoring and in the data loggings. Simultaneous fitting of bilateral hearing aids results in better compliance compared with sequential fitting. The addition of a second hearing aid after a relatively short period of monaural use may lead to inconsistent use of both hearing aids.
Parallelization of sequential Gaussian, indicator and direct simulation algorithms
NASA Astrophysics Data System (ADS)
Nunes, Ruben; Almeida, José A.
2010-08-01
Improving the performance and robustness of algorithms on new high-performance parallel computing architectures is a key issue in efficiently performing 2D and 3D studies with large amount of data. In geostatistics, sequential simulation algorithms are good candidates for parallelization. When compared with other computational applications in geosciences (such as fluid flow simulators), sequential simulation software is not extremely computationally intensive, but parallelization can make it more efficient and creates alternatives for its integration in inverse modelling approaches. This paper describes the implementation and benchmarking of a parallel version of the three classic sequential simulation algorithms: direct sequential simulation (DSS), sequential indicator simulation (SIS) and sequential Gaussian simulation (SGS). For this purpose, the source used was GSLIB, but the entire code was extensively modified to take into account the parallelization approach and was also rewritten in the C programming language. The paper also explains in detail the parallelization strategy and the main modifications. Regarding the integration of secondary information, the DSS algorithm is able to perform simple kriging with local means, kriging with an external drift and collocated cokriging with both local and global correlations. SIS includes a local correction of probabilities. Finally, a brief comparison is presented of simulation results using one, two and four processors. All performance tests were carried out on 2D soil data samples. The source code is completely open source and easy to read. It should be noted that the code is only fully compatible with Microsoft Visual C and should be adapted for other systems/compilers.
ERIC Educational Resources Information Center
Hwang, Ming-Yueh; Hong, Jon-Chao; Cheng, Hao-Yueh; Peng, Yu-Chi; Wu, Nien-Chen
2013-01-01
Do girls have more competition anxiety and exogenous cognitive load than equally able boys during the playing of stressful competitive on-line games? This question led to the adoption of a technology acceptance model to compare the influence factors of competitors in sequential and synchronous games. Confirmatory factor analysis of the data on 220…
Feature Selection based on Machine Learning in MRIs for Hippocampal Segmentation
NASA Astrophysics Data System (ADS)
Tangaro, Sabina; Amoroso, Nicola; Brescia, Massimo; Cavuoti, Stefano; Chincarini, Andrea; Errico, Rosangela; Paolo, Inglese; Longo, Giuseppe; Maglietta, Rosalia; Tateo, Andrea; Riccio, Giuseppe; Bellotti, Roberto
2015-01-01
Neurodegenerative diseases are frequently associated with structural changes in the brain. Magnetic resonance imaging (MRI) scans can show these variations and therefore can be used as a supportive feature for a number of neurodegenerative diseases. The hippocampus has been known to be a biomarker for Alzheimer disease and other neurological and psychiatric diseases. However, it requires accurate, robust, and reproducible delineation of hippocampal structures. Fully automatic methods are usually the voxel based approach; for each voxel a number of local features were calculated. In this paper, we compared four different techniques for feature selection from a set of 315 features extracted for each voxel: (i) filter method based on the Kolmogorov-Smirnov test; two wrapper methods, respectively, (ii) sequential forward selection and (iii) sequential backward elimination; and (iv) embedded method based on the Random Forest Classifier on a set of 10 T1-weighted brain MRIs and tested on an independent set of 25 subjects. The resulting segmentations were compared with manual reference labelling. By using only 23 feature for each voxel (sequential backward elimination) we obtained comparable state-of-the-art performances with respect to the standard tool FreeSurfer.
Vuillemin, Aurèle; Horn, Fabian; Alawi, Mashal; Henny, Cynthia; Wagner, Dirk; Crowe, Sean A.; Kallmeyer, Jens
2017-01-01
Extracellular DNA is ubiquitous in soil and sediment and constitutes a dominant fraction of environmental DNA in aquatic systems. In theory, extracellular DNA is composed of genomic elements persisting at different degrees of preservation produced by processes occurring on land, in the water column and sediment. Extracellular DNA can be taken up as a nutrient source, excreted or degraded by microorganisms, or adsorbed onto mineral matrices, thus potentially preserving information from past environments. To test whether extracellular DNA records lacustrine conditions, we sequentially extracted extracellular and intracellular DNA from anoxic sediments of ferruginous Lake Towuti, Indonesia. We applied 16S rRNA gene Illumina sequencing on both fractions to discriminate exogenous from endogenous sources of extracellular DNA in the sediment. Environmental sequences exclusively found as extracellular DNA in the sediment originated from multiple sources. For instance, Actinobacteria, Verrucomicrobia, and Acidobacteria derived from soils in the catchment. Limited primary productivity in the water column resulted in few sequences of Cyanobacteria in the oxic photic zone, whereas stratification of the water body mainly led to secondary production by aerobic and anaerobic heterotrophs. Chloroflexi and Planctomycetes, the main degraders of sinking organic matter and planktonic sequences at the water-sediment interface, were preferentially preserved during the initial phase of burial. To trace endogenous sources of extracellular DNA, we used relative abundances of taxa in the intracellular DNA to define which microbial populations grow, decline or persist at low density with sediment depth. Cell lysis became an important additional source of extracellular DNA, gradually covering previous genetic assemblages as other microbial genera became more abundant with depth. The use of extracellular DNA as nutrient by active microorganisms led to selective removal of sequences with lowest GC contents. We conclude that extracellular DNA preserved in shallow lacustrine sediments reflects the initial environmental context, but is gradually modified and thereby shifts from its stratigraphic context. Discrimination of exogenous and endogenous sources of extracellular DNA allows simultaneously addressing in-lake and post-depositional processes. In deeper sediments, the accumulation of resting stages and sequences from cell lysis would require stringent extraction and specific primers if ancient DNA is targeted. PMID:28798742
CACTI: free, open-source software for the sequential coding of behavioral interactions.
Glynn, Lisa H; Hallgren, Kevin A; Houck, Jon M; Moyers, Theresa B
2012-01-01
The sequential analysis of client and clinician speech in psychotherapy sessions can help to identify and characterize potential mechanisms of treatment and behavior change. Previous studies required coding systems that were time-consuming, expensive, and error-prone. Existing software can be expensive and inflexible, and furthermore, no single package allows for pre-parsing, sequential coding, and assignment of global ratings. We developed a free, open-source, and adaptable program to meet these needs: The CASAA Application for Coding Treatment Interactions (CACTI). Without transcripts, CACTI facilitates the real-time sequential coding of behavioral interactions using WAV-format audio files. Most elements of the interface are user-modifiable through a simple XML file, and can be further adapted using Java through the terms of the GNU Public License. Coding with this software yields interrater reliabilities comparable to previous methods, but at greatly reduced time and expense. CACTI is a flexible research tool that can simplify psychotherapy process research, and has the potential to contribute to the improvement of treatment content and delivery.
Reese, Tiffany A.; Bi, Kevin; Kambal, Amal; Filali-Mouhim, Ali; Beura, Lalit K.; Bürger, Matheus C.; Pulendran, Bali; Sekaly, Rafick; Jameson, Stephen C.; Masopust, David; Haining, W. Nicholas; Virgin, Herbert W.
2016-01-01
Summary Immune responses differ between laboratory mice and humans. Chronic infection with viruses and parasites are common in humans, but are absent in laboratory mice, and thus represent potential contributors to inter-species differences in immunity. To test this, we sequentially infected laboratory mice with herpesviruses, influenza, and an intestinal helminth, and compared their blood immune signatures to mock-infected mice before and after vaccination against Yellow Fever Virus (YFV-17D). Sequential infection altered pre- and post-vaccination gene expression, cytokines, and antibodies in blood. Sequential pathogen exposure induced gene signatures that recapitulated those seen in blood from pet store-raised versus laboratory mice, and adult versus cord blood in humans. Therefore basal and vaccine-induced murine immune responses are altered by infection with agents common outside of barrier facilities. This raises the possibility that we can improve mouse models of vaccination and immunity by selective microbial exposure of laboratory animals to mimic that of humans. PMID:27107939
The timing of language learning shapes brain structure associated with articulation.
Berken, Jonathan A; Gracco, Vincent L; Chen, Jen-Kai; Klein, Denise
2016-09-01
We compared the brain structure of highly proficient simultaneous (two languages from birth) and sequential (second language after age 5) bilinguals, who differed only in their degree of native-like accent, to determine how the brain develops when a skill is acquired from birth versus later in life. For the simultaneous bilinguals, gray matter density was increased in the left putamen, as well as in the left posterior insula, right dorsolateral prefrontal cortex, and left and right occipital cortex. For the sequential bilinguals, gray matter density was increased in the bilateral premotor cortex. Sequential bilinguals with better accents also showed greater gray matter density in the left putamen, and in several additional brain regions important for sensorimotor integration and speech-motor control. Our findings suggest that second language learning results in enhanced brain structure of specific brain areas, which depends on whether two languages are learned simultaneously or sequentially, and on the extent to which native-like proficiency is acquired.
Steblay, N; Dysart, J; Fulero, S; Lindsay, R C
2001-10-01
Most police lineups use a simultaneous presentation technique in which eyewitnesses view all lineup members at the same time. Lindsay and Wells (R. C. L. Lindsay & G. L. Wells, 1985) devised an alternative procedure, the sequential lineup, in which witnesses view one lineup member at a time and decide whether or not that person is the perpetrator prior to viewing the next lineup member. The present work uses the technique of meta-analysis to compare the accuracy rates of these presentation styles. Twenty-three papers were located (9 published and 14 unpublished), providing 30 tests of the hypothesis and including 4,145 participants. Results showed that identification of perpetrators from target-present lineups occurs at a higher rate from simultaneous than from sequential lineups. However, this difference largely disappears when moderator variables approximating real world conditions are considered. Also, correct rejection rates were significantly higher for sequential than simultaneous lineups and this difference is maintained or increased by greater approximation to real world conditions. Implications of these findings are discussed.
Blocking for Sequential Political Experiments
Moore, Sally A.
2013-01-01
In typical political experiments, researchers randomize a set of households, precincts, or individuals to treatments all at once, and characteristics of all units are known at the time of randomization. However, in many other experiments, subjects “trickle in” to be randomized to treatment conditions, usually via complete randomization. To take advantage of the rich background data that researchers often have (but underutilize) in these experiments, we develop methods that use continuous covariates to assign treatments sequentially. We build on biased coin and minimization procedures for discrete covariates and demonstrate that our methods outperform complete randomization, producing better covariate balance in simulated data. We then describe how we selected and deployed a sequential blocking method in a clinical trial and demonstrate the advantages of our having done so. Further, we show how that method would have performed in two larger sequential political trials. Finally, we compare causal effect estimates from differences in means, augmented inverse propensity weighted estimators, and randomization test inversion. PMID:24143061
Treatment of mites folliculitis with an ornidazole-based sequential therapy: A randomized trial.
Luo, Yang; Sun, Yu-Jiao; Zhang, Li; Luan, Xiu-Li
2016-07-01
Treatment of Demodex infestations is often inadequate and associated with low effective rate. We sought to evaluate the efficacy of an ornidazole-based sequential therapy for mites folliculitis treatment. Two-hundred patients with mites folliculitis were sequentially treated with either an ornidazole- or metronidazole-based regimen. Sebum cutaneum was extruded from the sebaceous glands of each patient's nose and the presence of Demodex mites were examined by light microscopy. The clinical manifestations of relapse of mites folliculitis were recorded and the subjects were followed up at 2, 4, 8, and 12 weeks post-treatment. Patients treated with the ornidazole-based regimen showed an overall effective rate of 94.0%. Additionally, at the 2, 4, 8, and 12-week follow-up, these patients had significantly lower rates of Demodex mite relapse and new lesion occurrence compared with patients treated with the metronidazole-based regimen (P < 0.05). Sequential therapy using ornidazole, betamethasone, and recombinant bovine basic fibroblast growth factor (rbFGF) gel is highly effective for treating mites folliculitis.
Effects of the exposure of TiO2 nanoparticles on basil (Ocimum basilicum) for two generations.
Tan, Wenjuan; Du, Wenchao; Darrouzet-Nardi, Anthony J; Hernandez-Viezcas, Jose A; Ye, Yuqing; Peralta-Videa, Jose R; Gardea-Torresdey, Jorge L
2018-09-15
There is a lack of information about the transgenerational effects of titanium dioxide nanoparticles (nano-TiO 2 ) in plants. This study aimed to evaluate the impacts of successive exposure of nano-TiO 2 with different surface properties to basil (Ocimum basilicum). Seeds from plants exposed or re-exposed to pristine, hydrophobic, or hydrophilic nano-TiO 2 were cultivated for 65 days in soil unamended or amended with 750 mg·kg -1 of the respective particles. Plant growth, concentration of titanium and essential elements, as well as content of carbohydrates and chlorophyll were evaluated. There were no differences on Ti concentration in roots of plants sequentially exposed to pristine or hydrophobic nano-TiO 2 , or in roots of plants exposed to the corresponding particle, only in the second cycle. However, sequential exposure to hydrophilic particles resulted in 65.2% less Ti in roots, compared to roots of plants exposed the same particles, only in the second cycle. The Ti concentrations in shoots were similar in all treatments. On the other hand, pristine and hydrophilic particles reduced Mg in root by 115% and 81%, respectively, while pristine and hydrophobic particles reduced Ni in shoot by 84% and 75%, respectively, compared to unexposed plants in both cycles. Sequential exposure to pristine nano-TiO 2 increased stomatal conductance (214%, p ≤ 0.10), compared to plants that were never exposed. Hydrophobic and hydrophilic nano-TiO 2 reduced chlorophyll b (52%) and total chlorophyll (30%) but increased total sugar (186%) and reducing sugar (145%), compared to unexposed plants in both cycles. Sequential exposure to hydrophobic or hydrophilic nano-TiO 2 resulted in more adverse effects on photosynthesis but in positive effects on plant growth, compared to pristine nano-TiO 2 . Copyright © 2018 Elsevier B.V. All rights reserved.
Suppressing correlations in massively parallel simulations of lattice models
NASA Astrophysics Data System (ADS)
Kelling, Jeffrey; Ódor, Géza; Gemming, Sibylle
2017-11-01
For lattice Monte Carlo simulations parallelization is crucial to make studies of large systems and long simulation time feasible, while sequential simulations remain the gold-standard for correlation-free dynamics. Here, various domain decomposition schemes are compared, concluding with one which delivers virtually correlation-free simulations on GPUs. Extensive simulations of the octahedron model for 2 + 1 dimensional Kardar-Parisi-Zhang surface growth, which is very sensitive to correlation in the site-selection dynamics, were performed to show self-consistency of the parallel runs and agreement with the sequential algorithm. We present a GPU implementation providing a speedup of about 30 × over a parallel CPU implementation on a single socket and at least 180 × with respect to the sequential reference.
Mueller, Claudius; Edmiston, Kirsten H.; Carpenter, Calvin; Gaffney, Eoin; Ryan, Ciara; Ward, Ronan; White, Susan; Memeo, Lorenzo; Colarossi, Cristina; Petricoin, Emanuel F.; Liotta, Lance A.; Espina, Virginia
2011-01-01
Background There is an urgent need to measure phosphorylated cell signaling proteins in cancer tissue for the individualization of molecular targeted kinase inhibitor therapy. However, phosphoproteins fluctuate rapidly following tissue procurement. Snap-freezing preserves phosphoproteins, but is unavailable in most clinics and compromises diagnostic morphology. Formalin fixation preserves tissue histomorphology, but penetrates tissue slowly, and is unsuitable for stabilizing phosphoproteins. We originated and evaluated a novel one-step biomarker and histology preservative (BHP) chemistry that stabilizes signaling protein phosphorylation and retains formalin-like tissue histomorphology with equivalent immunohistochemistry in a single paraffin block. Results Total protein yield extracted from BHP-fixed, routine paraffin-embedded mouse liver was 100% compared to snap-frozen tissue. The abundance of 14 phosphorylated proteins was found to be stable over extended fixation times in BHP fixed paraffin embedded human colon mucosa. Compared to matched snap-frozen tissue, 8 phosphoproteins were equally preserved in mouse liver, while AMPKβ1 Ser108 was slightly elevated after BHP fixation. More than 25 tissues from mouse, cat and human specimens were evaluated for preservation of histomorphology. Selected tissues were evaluated in a multi-site, independent pathology review. Tissue fixed with BHP showed equivalent preservation of cytoplasmic and membrane cytomorphology, with significantly better nuclear chromatin preservation by BHP compared to formalin. Immunohistochemical staining of 13 non-phosphorylated proteins, including estrogen receptor alpha, progesterone receptor, Ki-67 and Her2, was equal to or stronger in BHP compared to formalin. BHP demonstrated significantly improved immunohistochemical detection of phosphorylated proteins ERK Thr202/Tyr204, GSK3-α/β Ser21/Ser9, p38-MAPK Thr180/Tyr182, eIF4G Ser1108 and Acetyl-CoA Carboxylase Ser79. Conclusion In a single paraffin block BHP preserved the phosphorylation state of several signaling proteins at a level comparable to snap-freezing, while maintaining the full diagnostic immunohistochemical and histomorphologic detail of formalin fixation. This new tissue fixative has the potential to greatly facilitate personalized medicine, biobanking, and phospho-proteomic research. PMID:21858221
Posner, M. R.; Lorch, J. H.; Goloubeva, O.; Tan, M.; Schumaker, L. M.; Sarlis, N. J.; Haddad, R. I.; Cullen, K. J.
2011-01-01
Background: The association between human papillomavirus (HPV) and overall survival (OS) in oropharynx cancer (OPC) was retrospectively examined in TAX 324, a phase III trial of sequential therapy for locally advanced head and neck cancer. Methods: Accrual for TAX 324 was completed in 2003 and data updated through 2008. Pretherapy tumor biopsies were studied by PCR for human papillomavirus type 16 and linked to OS, progression-free survival (PFS) and demographics. Results: Of 264 patients with OPC, 111 (42%) had evaluable biopsies; 56 (50%) were HPV+ and 55 (50%) were HPV−. HPV+ patients were significantly younger (54 versus 58 years, P = 0.02), had T1/T2 primary cancers (49% versus 20%, P = 0.001), and had a performance status of zero (77% versus 49%, P = 0.003). OS and PFS were better for HPV+ patients (OS, hazard ratio = 0.20, P < 0.0001). Local–regional failure was less in HPV+ patients (13% versus 42%, P = 0.0006); at 5 years, 82% of HPV+ patients were alive compared with 35% of HPV− patients (P < 0.0001). Conclusions: HPV+ OPC has a different biology compared with HPV− OPC; 5-year OS, PFS, and local–regional control are unprecedented. These results support the possibility of selectively reducing therapy and long-term morbidity in HPV+ OPC while preserving survival and approaching HPV− disease with more aggressive treatment. PMID:21317223
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tfaily, Malak M.; Chu, Rosalie K.; Toyoda, Jason
A vast number of organic compounds are present in soil organic matter (SOM) and play an important role in the terrestrial carbon cycle, facilitate interactions between organisms, and represent a sink for atmospheric CO2. The diversity of different SOM compounds and their molecular characteristics is a function of the organic source material and biogeochemical history. By understanding how SOM composition changes with sources and the processes by which it is biogeochemically altered in different terrestrial ecosystems, it may be possible to predict nutrient and carbon cycling, response to system perturbations, and impact of climate change will have on SOM composition.more » In this study, a sequential chemical extraction procedure was developed to reveal the diversity of organic matter (OM) in different ecosystems and was compared to the previously published protocol using parallel solvent extraction (PSE). We compared six extraction methods using three sample types, peat soil, spruce forest soil and river sediment, so as to select the best method for extracting a representative fraction of organic matter from soils and sediments from a wide range of ecosystems. We estimated the extraction yield of dissolved organic carbon (DOC) by total organic carbon analysis, and measured the composition of extracted OM using high resolution mass spectrometry. This study showed that OM composition depends primarily on soil and sediment characteristics. Two sequential extraction protocols, progressing from polar to non-polar solvents, were found to provide the highest number and diversity of organic compounds extracted from the soil and sediments. Water (H2O) is the first solvent used for both protocols followed by either co-extraction with methanol-chloroform (MeOH-CHCl3) mixture, or acetonitrile (ACN) and CHCl3 sequentially. The sequential extraction protocol developed in this study offers improved sensitivity, and requires less sample compared to the PSE workflow where a new sample is used for each solvent type. Furthermore, a comparison of SOM composition from the different sample types revealed that our sequential protocol allows for ecosystem comparisons based on the diversity of compounds present, which in turn could provide new insights about source and processing of organic compounds in different soil and sediment types.« less
Tfaily, Malak M; Chu, Rosalie K; Toyoda, Jason; Tolić, Nikola; Robinson, Errol W; Paša-Tolić, Ljiljana; Hess, Nancy J
2017-06-15
A vast number of organic compounds are present in soil organic matter (SOM) and play an important role in the terrestrial carbon cycle, facilitate interactions between organisms, and represent a sink for atmospheric CO 2 . The diversity of different SOM compounds and their molecular characteristics is a function of the organic source material and biogeochemical history. By understanding how SOM composition changes with sources and the processes by which it is biogeochemically altered in different terrestrial ecosystems, it may be possible to predict nutrient and carbon cycling, response to system perturbations, and impact of climate change will have on SOM composition. In this study, a sequential chemical extraction procedure was developed to reveal the diversity of organic matter (OM) in different ecosystems and was compared to the previously published protocol using parallel solvent extraction (PSE). We compared six extraction methods using three sample types, peat soil, spruce forest soil and river sediment, so as to select the best method for extracting a representative fraction of organic matter from soils and sediments from a wide range of ecosystems. We estimated the extraction yield of dissolved organic carbon (DOC) by total organic carbon analysis, and measured the composition of extracted OM using high resolution mass spectrometry. This study showed that OM composition depends primarily on soil and sediment characteristics. Two sequential extraction protocols, progressing from polar to non-polar solvents, were found to provide the highest number and diversity of organic compounds extracted from the soil and sediments. Water (H 2 O) is the first solvent used for both protocols followed by either co-extraction with methanol-chloroform (MeOH-CHCl 3 ) mixture, or acetonitrile (ACN) and CHCl 3 sequentially. The sequential extraction protocol developed in this study offers improved sensitivity, and requires less sample compared to the PSE workflow where a new sample is used for each solvent type. Furthermore, a comparison of SOM composition from the different sample types revealed that our sequential protocol allows for ecosystem comparisons based on the diversity of compounds present, which in turn could provide new insights about source and processing of organic compounds in different soil and sediment types. Copyright © 2017 Elsevier B.V. All rights reserved.
Heart failure with preserved left ventricular systolic function: a hospital cohort study
Berry, C; Hogg, K; Norrie, J; Stevenson, K; Brett, M; McMurray, J
2005-01-01
Objective: To investigate how patients with heart failure with preserved left ventricular systolic function (LVSF) compare with patients with reduced LVSF. Design: Cohort study. Setting: Urban university hospital. Patients: 528 index emergency admissions with heart failure during the year 2000. Information on LVSF and follow up was available for 445 (84%) of these patients. Results: 130 (29%) patients had preserved LVSF (defined as an ejection fraction > 40%). The median follow up was 814 days (range 632–978 days). The average (SD) age was 72 (13) years. Women accounted for 62% and 45% of patients with preserved and reduced LVSF, respectively (p = 0.001). Patients with preserved LVSF (compared with those with reduced LVSF) had a higher prevalence of left ventricular hypertrophy (56% v 29%) and aortic valve disease (mean gradient > 20 mm Hg; 31% v 9%). Fewer patients with preserved LVSF received an angiotensin converting enzyme inhibitor (65% v 78%, p = 0.008) or spironolactone (12% v 21%, p = 0.027). Anaemia tended to occur more often in patients with preserved LVSF than in those with reduced LVSF (43% v 33% for women, p = 0.12; 59% v 49% for men, p = 0.22). There was a similarly high prevalence of significant renal dysfunction in both groups (estimated glomerular filtration rate < 60 ml/min/1.73 m2 in 68% with preserved and 64% with reduced LVSF, p = 0.40). Mortality was similar in both groups (preserved versus reduced 51 (39%) v 132 (42%), p = 0.51). Compared with patients with reduced LVSF, patients with preserved LVSF tended to have a lower risk of death or hospital admission for heart failure (56 (42%) v 165 (53%), p = 0.072) but a similar rate of death or readmission for any reason. Conclusion: Patients with preserved LVSF had more co-morbid problems than those with reduced LVSF; however, prognosis was similar for both groups. PMID:15958359
Yu, Cheng-Chia; Chen, Chin-Chuan
2018-01-01
The quality of biological samples greatly affects the accuracy of scientific results. However, RNA in cryopreserved tissues gradually degrades during storage, leading to errors in the results of subsequent experiments. A suitable sample preservative solution can prolong storage and enhance the research value of samples. Here, we developed a sample preservative solution using the properties of the ribonucleoside vanadyl complex (RVC) and compared its effects on RNA and DNA quality, protein activity, and tissue morphology with the commercially available and widely used RNAlater® Stabilization Solution. The results showed that both the RVC-based preservative solution and RNAlater can effectively delay RNA degradation in tissue samples stored at 4°C or −80°C compared with samples stored without any preservative solution. In contrast to RNAlater, the RVC-based preservative solution did not result in damage to the tissue morphology or a loss of protein activity. Additionally, the RVC-based preservative solution did not affect the RNA and genomic DNA contents of the tissue samples or the results of subsequent experimental analyses. An RVC-based reagent can be used as a multifunctional yet relatively inexpensive tissue preservative solution to provide a comprehensive and cost-effective method for preserving samples for tissue banks. PMID:29538436
Natriuretic Hormone: The Ultimate Determinant of the Preservation of External Sodium Balance
Bricker, Neal S.; Cain, Christopher D.; Shankel, Stewart
2014-01-01
The present manuscript focuses on a putative natriuretic hormone. It includes the history of a long-term search for the pure molecule, ranging from partial purification to synthesis. It includes a description of seven different bioassay systems used, a resume of the sequential steps in purification, and a summary of a series of experimental protocols employed in the effort to define the biologic properties of the inhibitor of sodium (Na) transport. Two closely related molecules were purified and synthesized. Both are xanthurenic acid derivatives (xanthurenic acid 8-O-β-D-glucoside and xanthurenic acid 8-O-sulfate). It is concluded that one or both of these two low molecular weight compounds (MW: 368 and 284) meet many of the criteria for the final modulator of Na excretion. PMID:25566186
Preservation of RNA and DNA from mammal samples under field conditions.
Camacho-Sanchez, Miguel; Burraco, Pablo; Gomez-Mestre, Ivan; Leonard, Jennifer A
2013-07-01
Ecological and conservation genetics require sampling of organisms in the wild. Appropriate preservation of the collected samples, usually by cryostorage, is key to the quality of the genetic data obtained. Nevertheless, cryopreservation in the field to ensure RNA and DNA stability is not always possible. We compared several nucleic acid preservation solutions appropriate for field sampling and tested them on rat (Rattus rattus) blood, ear and tail tip, liver, brain and muscle. We compared the efficacy of a nucleic acid preservation (NAP) buffer for DNA preservation against 95% ethanol and Longmire buffer, and for RNA preservation against RNAlater (Qiagen) and Longmire buffer, under simulated field conditions. For DNA, the NAP buffer was slightly better than cryopreservation or 95% ethanol, but high molecular weight DNA was preserved in all conditions. The NAP buffer preserved RNA as well as RNAlater. Liver yielded the best RNA and DNA quantity and quality; thus, liver should be the tissue preferentially collected from euthanized animals. We also show that DNA persists in nonpreserved muscle tissue for at least 1 week at ambient temperature, although degradation is noticeable in a matter of hours. When cryopreservation is not possible, the NAP buffer is an economical alternative for RNA preservation at ambient temperature for at least 2 months and DNA preservation for at least 10 months. © 2013 John Wiley & Sons Ltd.
Schulz, Daniela N; Kremers, Stef P J; Vandelanotte, Corneel; van Adrichem, Mathieu J G; Schneider, Francine; Candel, Math J J M; de Vries, Hein
2014-01-27
Web-based computer-tailored interventions for multiple health behaviors can have a significant public health impact. Yet, few randomized controlled trials have tested this assumption. The objective of this paper was to test the effects of a sequential and simultaneous Web-based tailored intervention on multiple lifestyle behaviors. A randomized controlled trial was conducted with 3 tailoring conditions (ie, sequential, simultaneous, and control conditions) in the Netherlands in 2009-2012. Follow-up measurements took place after 12 and 24 months. The intervention content was based on the I-Change model. In a health risk appraisal, all respondents (N=5055) received feedback on their lifestyle behaviors that indicated whether they complied with the Dutch guidelines for physical activity, vegetable consumption, fruit consumption, alcohol intake, and smoking. Participants in the sequential (n=1736) and simultaneous (n=1638) conditions received tailored motivational feedback to change unhealthy behaviors one at a time (sequential) or all at the same time (simultaneous). Mixed model analyses were performed as primary analyses; regression analyses were done as sensitivity analyses. An overall risk score was used as outcome measure, then effects on the 5 individual lifestyle behaviors were assessed and a process evaluation was performed regarding exposure to and appreciation of the intervention. Both tailoring strategies were associated with small self-reported behavioral changes. The sequential condition had the most significant effects compared to the control condition after 12 months (T1, effect size=0.28). After 24 months (T2), the simultaneous condition was most effective (effect size=0.18). All 5 individual lifestyle behaviors changed over time, but few effects differed significantly between the conditions. At both follow-ups, the sequential condition had significant changes in smoking abstinence compared to the simultaneous condition (T1 effect size=0.31; T2 effect size=0.41). The sequential condition was more effective in decreasing alcohol consumption than the control condition at 24 months (effect size=0.27). Change was predicted by the amount of exposure to the intervention (total visiting time: beta=-.06; P=.01; total number of visits: beta=-.11; P<.001). Both interventions were appreciated well by respondents without significant differences between conditions. Although evidence was found for the effectiveness of both programs, no simple conclusive finding could be drawn about which intervention mode was more effective. The best kind of intervention may depend on the behavior that is targeted or on personal preferences and motivation. Further research is needed to identify moderators of intervention effectiveness. The results need to be interpreted in view of the high and selective dropout rates, multiple comparisons, and modest effect sizes. However, a large number of people were reached at low cost and behavioral change was achieved after 2 years. Nederlands Trial Register: NTR 2168; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2168 (Archived by WebCite at http://www.webcitation.org/6MbUqttYB).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serin, E.; Codel, G.; Mabhouti, H.
Purpose: In small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation algorithm to accurately predict the dose, especially in the presence of tissue heterogeneities. In this study, dosimetric accuracy of Monte Carlo (MC) advanced dose calculation and sequential algorithms of Multiplan treatment planning system were investigated for small radiation fields incident on homogeneous and heterogeneous geometries. Methods: Small open fields of fixed cones of Cyberknife M6 unit 100 to 500 mm2 were used for this study. The fields were incident on in house phantom containing lung, air, and bone inhomogeneities and also homogeneous phantom.more » Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. The dosimetric accuracy of MC and sequential algorithms in the presence of the inhomogeneities was compared against EBT3 film dosimetry Results: Open field tests in a homogeneous phantom showed good agreement between two algorithms and film measurement For MC algorithm, the minimum gamma analysis passing rates between measured and calculated dose distributions were 99.7% and 98.3% for homogeneous and inhomogeneous fields in the case of lung and bone respectively. For sequential algorithm, the minimum gamma analysis passing rates were 98.9% and 92.5% for for homogeneous and inhomogeneous fields respectively for used all cone sizes. In the case of the air heterogeneity, the differences were larger for both calculation algorithms. Overall, when compared to measurement, the MC had better agreement than sequential algorithm. Conclusion: The Monte Carlo calculation algorithm in the Multiplan treatment planning system is an improvement over the existing sequential algorithm. Dose discrepancies were observed for in the presence of air inhomogeneities.« less
Pellacani, G; Peris, K; Guillen, C; Clonier, F; Larsson, T; Venkata, R; Puig, S
2015-11-01
Actinic keratoses (AKs) are precursors to invasive squamous cell carcinoma and can progress if untreated. Limited data support the use of ingenol mebutate to treat AKs on more than one area of the body simultaneously. To investigate safety, efficacy and treatment satisfaction when treating separate areas simultaneously or sequentially with different concentrations of ingenol mebutate gel. In this phase IIIb study (NCT01787383), patients with clinically visible, non-hyperkeratotic AKs on two separate treatment areas (face/scalp and trunk/extremities) were randomized to simultaneous or sequential treatment with ingenol mebutate gel (0.015% and 0.05%). Endpoints included composite local skin response (LSR) score 3 days after first application, complete AK clearance and percentage reduction in AKs at week 8. There were no statistically significant differences between simultaneous (n = 101) and sequential (n = 98) groups in composite LSR score (10.4 vs. 9.7), complete clearance (52.7% vs. 46.9%) or percentage reduction in AKs (83.4% vs. 79.1%). Mean composite LSR scores on face/scalp and trunk/extremities were similar for both groups. Adverse event (AE) incidence was comparable between groups, the most common treatment-related AEs being pruritus and pain at the application site. Treating AKs with ingenol mebutate simultaneously or sequentially gave similar results in terms of tolerability (LSR score, AEs) and efficacy (complete clearance). Therefore, the physician and patient can select the most convenient treatment regimen, with confidence in achieving a similar outcome. © 2015 LEO Pharma A/S. Journal of the European Academy of Dermatology and Venereology published by John Wiley & Sons, Ltd. on behalf of European Academy of Dermatology and Venereology.
Kumar, U Ajith; Maruthy, Sandeep; Chandrakant, Vishwakarma
2009-03-01
Distortion product otoacoustic emissions are one form of evoked otoacoustic emissions. DPOAEs provide the frequency specific information about the hearing status in mid and high frequency regions. But in most screening protocols TEOAEs are preferred as it requires less time compared to DPOAE. This is because, in DPOAE each stimulus is presented one after the other and responses are analyzed. Grason and Stadler Incorporation 60 (GSI-60) offer simultaneous presentation of four sets of primary tones at a time and checks for the DPOAE. In this mode of presentation, all the pairs are presented at a time and following that response is extracted separately whereas, in sequential mode primaries are presented in orderly fashion one after the other. In this article simultaneous and sequential protocols were used to compare the Distortion product otoacoustic emission amplitude, noise floor and administration time in individuals with normal hearing and mild sensori-neural (SN) hearing loss. In simultaneous protocols four sets of primary tones (i.e. 8 tones) were presented together whereas, in sequential presentation mode one set of primary tones was presented each time. Simultaneous protocol was completed in less than half the time required for the completion of sequential protocol. Two techniques yielded similar results at frequencies above 1000 Hz only in normal hearing group. In SN hearing loss group simultaneous presentation yielded signifi cantly higher noise floors and distortion product amplitudes. This result challenges the use of simultaneous presentation technique in neonatal hearing screening programmes and on other pathologies. This discrepancy between two protocols may be due to some changes in biomechanical process in the cochlear and/or due to higher distortion/noise produced by the system during the simultaneous presentation mode.
Boal Carvalho, Pedro; Magalhães, Joana; Dias de Castro, Francisca; Rosa, Bruno; Cotter, José
2017-03-31
Helicobacter pylori eradication has become increasingly difficult as resistances to several antibiotics develop. We aimed to compare Helicobacter pylori eradication rates between triple therapy and sequential therapy in a naive Portuguese population. Prospective randomized trial including consecutive patients referred for first-line Helicobacter pylori eradication treatment. previous gastric surgery/neoplasia, pregnancy/lactancy, allergy to any of the drugs. The compared eradication regimens were triple therapy (pantoprazol, amoxicillin and clarithromycin 12/12 hours, 14 days) and sequential therapy (pantoprazol 12/12 hours for 10 days, amoxicillin 12/12 hours for days 1 - 5 and clarithromycin plus metronidazol 12/12 hours during days 6 - 10). Eradication success was confirmed with urea breath test. Statistical analysis was performed with SPSS v21.0 and a p-value < 0.05 was considered statistically significant. Included 60 patients, 39 (65%) female with mean age 52 years (SD ± 14.3). Treatment groups were homogeneous for gender, age, indication for treatment and smoking status. No statistical differences were encountered between sequential and triple therapy eradication rates (86.2% vs 77.4%, p = 0.379), global eradication rate was 82%. Tobacco consumption was associated with a significantly lower eradication success (54.5 vs 87.8%, p = 0.022). In this randomized controlled trial in a naive Portuguese population, we found a satisfactory global Helicobacter pylori eradication rate of 82%, with no statistical differences observed in the efficacy of the treatment between triple and sequential regimens. These results support the use of either therapy for the first-line eradication of Helicobacter pylori.
Stereopsis, vertical disparity and relief transformations.
Gårding, J; Porrill, J; Mayhew, J E; Frisby, J P
1995-03-01
The pattern of retinal binocular disparities acquired by a fixating visual system depends on both the depth structure of the scene and the viewing geometry. This paper treats the problem of interpreting the disparity pattern in terms of scene structure without relying on estimates of fixation position from eye movement control and proprioception mechanisms. We propose a sequential decomposition of this interpretation process into disparity correction, which is used to compute three-dimensional structure up to a relief transformation, and disparity normalization, which is used to resolve the relief ambiguity to obtain metric structure. We point out that the disparity normalization stage can often be omitted, since relief transformations preserve important properties such as depth ordering and coplanarity. Based on this framework we analyse three previously proposed computational models of disparity processing; the Mayhew and Longuet-Higgins model, the deformation model and the polar angle disparity model. We show how these models are related, and argue that none of them can account satisfactorily for available psychophysical data. We therefore propose an alternative model, regional disparity correction. Using this model we derive predictions for a number of experiments based on vertical disparity manipulations, and compare them to available experimental data. The paper is concluded with a summary and a discussion of the possible architectures and mechanisms underling stereopsis in the human visual system.
Le, Duc H T; Tsutsui, Yoko; Sugawara-Narutaki, Ayae; Yukawa, Hiroshi; Baba, Yoshinobu; Ohtsuki, Chikara
2017-09-01
We have recently developed a novel double-hydrophobic elastin-like triblock polypeptide called GPG, designed after the uneven distribution of two different hydrophobic domains found in elastin, an extracellular matrix protein providing elasticity and resilience to tissues. Upon temperature trigger, GPG undergoes a sequential self-assembling process to form flexible beaded nanofibers with high homogeneity and excellent dispersibility in water. Given that GPG might be a potential elastin-mimetic material, we sought to explore the biological activities of this block polypeptide. Besides GPG, several functionalized derivatives were also constructed by fusing functional motifs such as KAAK or KAAKGRGDS at the C-terminal of GPG. Although the added motifs affected the kinetics of fiber formation and β-sheet contents, all three GPGs assembled into beaded nanofibers at the physiological temperature. The resulting GPG nanofibers preserved their beaded structures in cell culture medium; therefore, they were coated on polystyrene substrates to study their cytocompatibility toward mouse embryonic fibroblasts, NIH-3T3. Among the three polypeptides, GPG having the cell-binding motif GRGDS derived from fibronectin showed excellent cell adhesion and cell proliferation properties compared to other conventional materials, suggesting its promising applications as extracellular matrices for mammalian cells. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2475-2484, 2017. © 2017 Wiley Periodicals, Inc.
Whole head quantitative susceptibility mapping using a least-norm direct dipole inversion method.
Sun, Hongfu; Ma, Yuhan; MacDonald, M Ethan; Pike, G Bruce
2018-06-15
A new dipole field inversion method for whole head quantitative susceptibility mapping (QSM) is proposed. Instead of performing background field removal and local field inversion sequentially, the proposed method performs dipole field inversion directly on the total field map in a single step. To aid this under-determined and ill-posed inversion process and obtain robust QSM images, Tikhonov regularization is implemented to seek the local susceptibility solution with the least-norm (LN) using the L-curve criterion. The proposed LN-QSM does not require brain edge erosion, thereby preserving the cerebral cortex in the final images. This should improve its applicability for QSM-based cortical grey matter measurement, functional imaging and venography of full brain. Furthermore, LN-QSM also enables susceptibility mapping of the entire head without the need for brain extraction, which makes QSM reconstruction more automated and less dependent on intermediate pre-processing methods and their associated parameters. It is shown that the proposed LN-QSM method reduced errors in a numerical phantom simulation, improved accuracy in a gadolinium phantom experiment, and suppressed artefacts in nine subjects, as compared to two-step and other single-step QSM methods. Measurements of deep grey matter and skull susceptibilities from LN-QSM are consistent with established reconstruction methods. Copyright © 2018 Elsevier Inc. All rights reserved.
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring.
Masa, Juan F; Corral, Jaime; Pereira, Ricardo; Duran-Cantolla, Joaquin; Cabello, Marta; Hernández-Blasco, Luis; Monasterio, Carmen; Alonso-Fernandez, Alberto; Chiner, Eusebi; Vázquez-Polo, Francisco-José; Montserrat, Jose M
2013-04-01
Automatic home respiratory polygraphy (HRP) scoring functions can potentially confirm the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS) (obviating technician scoring) in a substantial number of patients. The result would have important management and cost implications. The aim of this study was to determine the diagnostic cost-effectiveness of a sequential HRP scoring protocol (automatic and then manual for residual cases) compared with manual HRP scoring, and with in-hospital polysomnography. We included suspected SAHS patients in a multicentre study and assigned them to home and hospital protocols at random. We constructed receiver operating characteristic (ROC) curves for manual and automatic scoring. Diagnostic agreement for several cut-off points was explored and costs for two equally effective alternatives were calculated. Of 366 randomised patients, 348 completed the protocol. Manual scoring produced better ROC curves than automatic scoring. There was no sensitive automatic or subsequent manual HRP apnoea-hypopnoea index (AHI) cut-off point. The specific cut-off points for automatic and subsequent manual HRP scorings (AHI >25 and >20, respectively) had a specificity of 93% for automatic and 94% for manual scorings. The costs of manual protocol were 9% higher than sequential HRP protocol; these were 69% and 64%, respectively, of the cost of the polysomnography. A sequential HRP scoring protocol is a cost-effective alternative to polysomnography, although with limited cost savings compared to HRP manual scoring.
De Britto, R L; Vanamail, P; Sankari, T; Vijayalakshmi, G; Das, L K; Pani, S P
2015-06-01
Till today, there is no effective treatment protocol for the complete clearance of Wuchereria bancrofti (W.b) infection that causes secondary lymphoedema. In a double blind randomized control trial (RCT), 146 asymptomatic W. b infected individuals were randomly assigned to one of the four regimens for 12 days, DEC 300 mg + Doxycycline 100 mg coadministration or DEC 300 mg + Albendazole 400 mg co-administration or DEC 300 mg + Albendazole 400 mg sequential administration or control regimen DEC 300 mg and were followed up at 13, 26 and 52 weeks post-treatment for the clearance of infection. At intake, there was no significant variation in mf counts (F(3,137)=0.044; P=0.988) and antigen levels (F(3,137)=1.433; P=0.236) between the regimens. Primary outcome analysis showed that DEC + Albendazole sequential administration has an enhanced efficacy over DEC + Albendazole co-administration (80.6 Vs 64.7%), and this regimen is significantly different when compared to DEC + doxycycline co-administration and control (P<0.05), in clearing microfilaria in 13 weeks. Secondary outcome analysis showed that, all the trial regimens were comparable to control regimen in clearing antigen (F(3, 109)=0.405; P=0.750). Therefore, DEC + Albendazole sequential administration appears to be a better option for rapid clearance of W. b microfilariae in 13 weeks time. (Clinical trials.gov identifier - NCT02005653).
Feng, Xiuli; Zhang, Yan; Li, Tao; Li, Yu
2017-01-01
Combination of chemotherapy and epidermal growth factor receptor-tyrosine kinase inhibitors (EGFR-TKIs) had been proved to be a potent anti-drug for the treatment of tumors. However, survival time was not extended for the patients with lung adenocarcinoma (AdC) compared with first-line chemotherapy. In the present study, we attempt to assess the optimal schedule of the combined administration of pemetrexed and icotinib/erlotinib in AdC cell lines. Human lung AdC cell lines with wild-type (A549), EGFR T790M (H1975) and activating EGFR mutation (HCC827) were applied in vitro to assess the differential efficacy of various sequential regimens on cell viability, cell apoptosis and cell cycle distribution. The results suggested that the antiproliferative effect of the sequence of pemetrexed followed by icotinib/erlotinib was more effective than that of icotinib/erlotinib followed by pemetrexed. Additionally, a reduction of G1 phase and increased S phase in sequence of pemetrexed followed by icotinib/erlotinib was also observed, promoting cell apoptosis. Thus, the sequential administration of pemetrexed followed by icotinib/erlotinib exerted a synergistic effect on HCC827 and H1975 cell lines compared with the reverse sequence. The sequential treatment of pemetrexed followed by icotinib/erlotinib has been demonstrated promising results. This treatment strategy warrants further confirmation in patients with advanced lung AdC. PMID:29371987
Feng, Xiuli; Zhang, Yan; Li, Tao; Li, Yu
2017-12-26
Combination of chemotherapy and epidermal growth factor receptor-tyrosine kinase inhibitors (EGFR-TKIs) had been proved to be a potent anti-drug for the treatment of tumors. However, survival time was not extended for the patients with lung adenocarcinoma (AdC) compared with first-line chemotherapy. In the present study, we attempt to assess the optimal schedule of the combined administration of pemetrexed and icotinib/erlotinib in AdC cell lines. Human lung AdC cell lines with wild-type (A549), EGFR T790M (H1975) and activating EGFR mutation (HCC827) were applied in vitro to assess the differential efficacy of various sequential regimens on cell viability, cell apoptosis and cell cycle distribution. The results suggested that the antiproliferative effect of the sequence of pemetrexed followed by icotinib/erlotinib was more effective than that of icotinib/erlotinib followed by pemetrexed. Additionally, a reduction of G1 phase and increased S phase in sequence of pemetrexed followed by icotinib/erlotinib was also observed, promoting cell apoptosis. Thus, the sequential administration of pemetrexed followed by icotinib/erlotinib exerted a synergistic effect on HCC827 and H1975 cell lines compared with the reverse sequence. The sequential treatment of pemetrexed followed by icotinib/erlotinib has been demonstrated promising results. This treatment strategy warrants further confirmation in patients with advanced lung AdC.
Stanley, Brett J; Antonio, Karen
2012-11-01
Several methods exist for the measurement of cyanide levels in treated wastewater,typically requiring preservation of the sample with sodium hydroxide to minimize loss of hydrogen cyanide gas (HCN). Recent reports have shown that cyanide levels may increase with chlorination or preservation. In this study, three flow injection analysis methods involving colorimetric and amperometric detection were compared within one laboratory, as well as across separate laboratories and equipment. Split wastewater samples from eight facilities and three different sampling periods were tested. An interlaboratory confidence interval of 3.5 ppb was calculated compared with the intralaboratory reporting limit of 2 ppb. The results show that free cyanide measurements are not statistically different than total cyanide levels. An artificial increase in cyanide level is observed with all methods for preserved samples relative to nonpreserved samples, with an average increase of 2.3 ppb. The possible loss of cyanide without preservation is shown to be statistically insignificant if properly stored up to 48 hours. The cyanide increase with preservation is further substantiated with the method of standard additions and is not a matrix interference. The increase appears to be correlated with the amount of cyanide observed without preservation, which appears to be greater in those facilities that disinfect their wastewater with chlorine, followed by dechlorination with sodium bisulfite.
Ercan, Müjgan; Akbulut, Emiş Deniz; Abuşoğlu, Sedat; Yılmaz, Fatma Meriç; Oğuz, Esra Fırat; Topçuoğlu, Canan; Öztekin, Volkan; Boğdaycıoğlu, Nihal
2015-09-01
Laboratories determine the most appropriate approach for the collection and transport of urine specimens. We investigated the effect of a chlorhexidine-based preservative tube on sample stability, compared the results of refrigerated polystyrene tubes with no additives, and investigated the effect of temperature on the performance of preservative tubes. Fresh urine specimen (n=48) aliquots in BD Vacutainer® Plus Urinalysis Preservative Tubes and polystyrene tubes were analyzed on an Iris Diagnostics iQ200. Samples in polystyrene tubes were refrigerated for 4 and 8h. Four aliquots in preservative tubes were kept at room temperature for 4, 8, 24, and 72h, while two aliquots were kept on ice for 4 and 8h. There was good agreement for all chemistry and microscopy parameters with the exceptions of white blood cells (WBCs) at 24 and 72h and red blood cells (RBCs) at 72h. Preservative tubes on ice showed a significant decrease in concordance of WBCs and calcium oxalate (CaOx) parameters compared with the results at room temperature. Results of refrigerated polystyrene tubes showed good agreement with the exceptions of WBC clumps and amorphous crystal at 8h. A chlorhexidine-containing preservative tube seems advantageous for urine sample transport from outside healthcare services. A preservative tube offers comparable results with urine samples kept in a refrigerator for 4-8h for the majority of parameters. Keeping samples at room temperature is recommended when preservative tubes are used because ice produces a negative effect on WBCs and CaOx. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Pilotte, Nils; Baumer, Ben; Grant, Jessica; Asbjornsdottir, Kristjana; Schaer, Fabian; Hu, Yan; Aroian, Raffi; Walson, Judd; Williams, Steven A.
2018-01-01
Background Proper collection and storage of fecal samples is necessary to guarantee the subsequent reliability of DNA-based soil-transmitted helminth diagnostic procedures. Previous research has examined various methods to preserve fecal samples for subsequent microscopic analysis or for subsequent determination of overall DNA yields obtained following DNA extraction. However, only limited research has focused on the preservation of soil-transmitted helminth DNA in stool samples stored at ambient temperature or maintained in a cold chain for extended periods of time. Methodology Quantitative real-time PCR was used in this study as a measure of the effectiveness of seven commercially available products to preserve hookworm DNA over time and at different temperatures. Results were compared against “no preservative” controls and the “gold standard” of rapidly freezing samples at -20°C. The preservation methods were compared at both 4°C and at simulated tropical ambient temperature (32°C) over a period of 60 days. Evaluation of the effectiveness of each preservative was based on quantitative real-time PCR detection of target hookworm DNA. Conclusions At 4°C there were no significant differences in DNA amplification efficiency (as measured by Cq values) regardless of the preservation method utilized over the 60-day period. At 32°C, preservation with FTA cards, potassium dichromate, and a silica bead two-step desiccation process proved most advantageous for minimizing Cq value increases, while RNA later, 95% ethanol and Paxgene also demonstrate some protective effect. These results suggest that fecal samples spiked with known concentrations of hookworm-derived egg material can remain at 4°C for 60 days in the absence of preservative, without significant degradation of the DNA target. Likewise, a variety of preservation methods can provide a measure of protection in the absence of a cold chain. As a result, other factors, such as preservative toxicity, inhibitor resistance, preservative cost, shipping requirements, sample infectivity, and labor costs should be considered when deciding upon an appropriate method for the storage of fecal specimens for subsequent PCR analysis. Balancing logistical factors and the need to preserve the target DNA, we believe that under most circumstances 95% ethanol provides the most pragmatic choice for preserving stool samples in the field. PMID:29346412
Cressman, Erik N K; Shenoi, Mithun M; Edelman, Theresa L; Geeslin, Matthew G; Hennings, Leah J; Zhang, Yan; Iaizzo, Paul A; Bischof, John C
2012-01-01
To investigate simultaneous and sequential injection thermochemical ablation in a porcine model, and compare them to sham and acid-only ablation. This IACUC-approved study involved 11 pigs in an acute setting. Ultrasound was used to guide placement of a thermocouple probe and coaxial device designed for thermochemical ablation. Solutions of 10 M acetic acid and NaOH were used in the study. Four injections per pig were performed in identical order at a total rate of 4 mL/min: saline sham, simultaneous, sequential, and acid only. Volume and sphericity of zones of coagulation were measured. Fixed specimens were examined by H&E stain. Average coagulation volumes were 11.2 mL (simultaneous), 19.0 mL (sequential) and 4.4 mL (acid). The highest temperature, 81.3°C, was obtained with simultaneous injection. Average temperatures were 61.1°C (simultaneous), 47.7°C (sequential) and 39.5°C (acid only). Sphericity coefficients (0.83-0.89) had no statistically significant difference among conditions. Thermochemical ablation produced substantial volumes of coagulated tissues relative to the amounts of reagents injected, considerably greater than acid alone in either technique employed. The largest volumes were obtained with sequential injection, yet this came at a price in one case of cardiac arrest. Simultaneous injection yielded the highest recorded temperatures and may be tolerated as well as or better than acid injection alone. Although this pilot study did not show a clear advantage for either sequential or simultaneous methods, the results indicate that thermochemical ablation is attractive for further investigation with regard to both safety and efficacy.
Sequential voluntary cough and aspiration or aspiration risk in Parkinson's disease.
Hegland, Karen Wheeler; Okun, Michael S; Troche, Michelle S
2014-08-01
Disordered swallowing, or dysphagia, is almost always present to some degree in people with Parkinson's disease (PD), either causing aspiration or greatly increasing the risk for aspiration during swallowing. This likely contributes to aspiration pneumonia, a leading cause of death in this patient population. Effective airway protection is dependent upon multiple behaviors, including cough and swallowing. Single voluntary cough function is disordered in people with PD and dysphagia. However, the appropriate response to aspirate material is more than one cough, or sequential cough. The goal of this study was to examine voluntary sequential coughing in people with PD, with and without dysphagia. Forty adults diagnosed with idiopathic PD produced two trials of sequential voluntary cough. The cough airflows were obtained using pneumotachograph and facemask and subsequently digitized and recorded. All participants received a modified barium swallow study as part of their clinical care, and the worst penetration-aspiration score observed was used to determine whether the patient had dysphagia. There were significant differences in the compression phase duration, peak expiratory flow rates, and amount of air expired of the sequential cough produced by participants with and without dysphagia. The presence of dysphagia in people with PD is associated with disordered cough function. Sequential cough, which is important in removing aspirate material from large- and smaller-diameter airways, is also impaired in people with PD and dysphagia compared with those without dysphagia. There may be common neuroanatomical substrates for cough and swallowing impairment in PD leading to the co-occurrence of these dysfunctions.
Preservation of rat hearts in subfreezing temperature isochoric conditions to - 8 °C and 78 MPa.
Wan, Lili; Powell-Palm, Matthew J; Lee, Charles; Gupta, Anshal; Weegman, Bradley P; Clemens, Mark G; Rubinsky, Boris
2018-02-12
Isochoric (constant volume) preservation at subfreezing temperatures is being investigated as a novel method for preserving cells and organs. This study is a first initial effort to evaluate the efficacy of this method for heart preservation, and to provide a preliminary outline of appropriate preservation parameters. To establish a baseline for further studies, rat hearts were preserved in a University of Wisconsin (UW) intracellular solution for one hour under isochoric conditions at: 0 °C (atmospheric pressure - 0.1 MPa), - 4 °C (41 MPa), - 6 °C (60 MPa) and - 8 °C (78 MPa). The viability of the heart was evaluated using Langendorff perfusion and histological examination. The physiological performance of hearts preserved at - 4 °C (41 MPa) was comparable to that of a heart preserved on ice at atmospheric pressure, with no statistically significant difference in histological injury score. However, hearts preserved at -4 °C displayed substantially reduced interstitial edema compared to hearts preserved by conventional hypothermic preservation in UW on ice at atmospheric pressure, suggesting significant protection from increased vascular permeability following preservation. Hearts preserved at - 6 °C (60 MPa) suffered injury from cellular swelling and extensive edema, and at - 8 °C (78 MPa) hearts experienced significant morphological disruption. To the best of our knowledge, this is the first publication showing that a mammalian organ can survive low subfreezing temperatures without the use of a cryoprotective additive. Lowering the preservation temperature reduces metabolism and improves preservation quality, and these results suggest that improvements in preservation are possible at subzero temperatures with low to moderate pressures observed at -4 °C. Notably, tissue damage was observed at lower temperatures (-6 °C or below) accompanying further elevation of pressure associated with isochoric preservation that may prove detrimental. Therefore, subfreezing temperature isochoric preservation protocols should optimize, a combination of temperature and pressure that will minimize the negative effects of elevated pressure while retaining the beneficial effect of lower temperatures and reduced metabolism. Copyright © 2018. Published by Elsevier Inc.
Sequential detection of web defects
Eichel, Paul H.; Sleefe, Gerard E.; Stalker, K. Terry; Yee, Amy A.
2001-01-01
A system for detecting defects on a moving web having a sequential series of identical frames uses an imaging device to form a real-time camera image of a frame and a comparitor to comparing elements of the camera image with corresponding elements of an image of an exemplar frame. The comparitor provides an acceptable indication if the pair of elements are determined to be statistically identical; and a defective indication if the pair of elements are determined to be statistically not identical. If the pair of elements is neither acceptable nor defective, the comparitor recursively compares the element of said exemplar frame with corresponding elements of other frames on said web until one of the acceptable or defective indications occur.
López, L M; Vicente, R; Ramos, F; Palacios, L; Calvo, A; Hernández, S; Borro, J M; Morales, P; Montero, R
1996-03-01
Cystic fibrosis (CF) is a disease characterized mainly by altered exocrine gland function that eventually produces irreversible dysfunction of the pancreas and lungs. The respiratory insufficiency that develops in CF patients in the advanced stages of disease can only be corrected at this time by lung or heart-lung transplantation. We describe our experience with 6 terminal phase CF patients who underwent sequential double lung transplantation (SDLT). Anesthesia was intravenous, with exhaustive hemodynamic and respiratory monitoring. During surgery the most frequently encountered hemodynamic complications were low minute volume, arterial hypotension and irregular heart rate. The main respiratory complications were hypoxemia, hypercapnia and pulmonary edema of the implanted lung, which developed in all cases to varying degrees related to the organ's state of preservation and duration of ischemia. Other complications were the need for extracorporeal circulation in 1 case, oliguria and blood loss requiring multiple transfusions. The most critical moments were at the time of clamping the pulmonary artery, the period after revascularization of the donated lung, and at the start of patient ventilation through the first implanted lung so that the second could be implanted. Although our series is small, it is of interest given the limited Spanish experience with lung transplantation in CF patients, and the good early results obtained, which are similar to those reported for other diseases.
A reduced order model based on Kalman filtering for sequential data assimilation of turbulent flows
NASA Astrophysics Data System (ADS)
Meldi, M.; Poux, A.
2017-10-01
A Kalman filter based sequential estimator is presented in this work. The estimator is integrated in the structure of segregated solvers for the analysis of incompressible flows. This technique provides an augmented flow state integrating available observation in the CFD model, naturally preserving a zero-divergence condition for the velocity field. Because of the prohibitive costs associated with a complete Kalman Filter application, two model reduction strategies have been proposed and assessed. These strategies dramatically reduce the increase in computational costs of the model, which can be quantified in an augmentation of 10%- 15% with respect to the classical numerical simulation. In addition, an extended analysis of the behavior of the numerical model covariance Q has been performed. Optimized values are strongly linked to the truncation error of the discretization procedure. The estimator has been applied to the analysis of a number of test cases exhibiting increasing complexity, including turbulent flow configurations. The results show that the augmented flow successfully improves the prediction of the physical quantities investigated, even when the observation is provided in a limited region of the physical domain. In addition, the present work suggests that these Data Assimilation techniques, which are at an embryonic stage of development in CFD, may have the potential to be pushed even further using the augmented prediction as a powerful tool for the optimization of the free parameters in the numerical simulation.
Three-body effects in the Hoyle-state decay
NASA Astrophysics Data System (ADS)
Refsgaard, J.; Fynbo, H. O. U.; Kirsebom, O. S.; Riisager, K.
2018-04-01
We use a sequential R-matrix model to describe the breakup of the Hoyle state into three α particles via the ground state of 8Be. It is shown that even in a sequential picture, features resembling a direct breakup branch appear in the phase-space distribution of the α particles. We construct a toy model to describe the Coulomb interaction in the three-body final state and its effects on the decay spectrum are investigated. The framework is also used to predict the phase-space distribution of the α particles emitted in a direct breakup of the Hoyle state and the possibility of interference between a direct and sequential branch is discussed. Our numerical results are compared to the current upper limit on the direct decay branch determined in recent experiments.
Spatial-sequential and spatial-simultaneous working memory in individuals with Williams syndrome.
Lanfranchi, Silvia; De Mori, Letizia; Mammarella, Irene C; Carretti, Barbara; Vianello, Renzo
2015-05-01
The aim of the present study was to compare visuospatial working memory performance in 18 individuals with Williams syndrome (WS) and 18 typically developing (TD) children matched for nonverbal mental age. Two aspects were considered: task presentation format (i.e., spatial-sequential or spatial-simultaneous), and level of attentional control (i.e., passive or active tasks). Our results showed that individuals with WS performed less well than TD children in passive spatial-simultaneous tasks, but not in passive spatial-sequential tasks. The former's performance was also worse in both active tasks. These findings suggest an impairment in the spatial-simultaneous working memory of individuals with WS, together with a more generalized difficulty in tasks requiring information storage and concurrent processing, as seen in other etiologies of intellectual disability.
Faria, Rita; Spackman, Eldon; Burch, Jane; Corbacho, Belen; Todd, Derick; Pepper, Chris; Woolacott, Nerys; Palmer, Stephen
2013-07-01
The National Institute for Health and Clinical Excellence (NICE) invited the manufacturer of dabigatran etexilate (Boehringer Ingelheim Ltd, UK) to submit evidence for the clinical and cost-effectiveness of this drug for the prevention of stroke and systemic embolism in patients with non-valvular atrial fibrillation (AF) as part of the NICE single technology appraisal process. The Centre for Reviews and Dissemination and the Centre for Health Economics at the University of York were commissioned to act as the evidence review group (ERG). This article presents a summary of the manufacturer's submission, the ERG report and the subsequent development of NICE guidance for the use of dabigatran within the UK National Health Service. Dabigatran was granted marketing authorisation by the European Medicines Agency for a sequential dosing regimen (DBG sequential), in which patients under 80 years are treated with dabigatran 150 mg twice daily (DBG150) and patients 80 years and over are given dabigatran 110 mg twice daily (DBG110). NICE decisions are bound by the marketing authorisation; therefore, the decision problem faced by the committee was whether the DBG sequential regimen was effective and cost-effective compared with warfarin or aspirin for patients with non-valvular AF and one or more risk factors. The RE-LY trial, a large multi-centre non-inferiority randomised clinical trial, was the primary source of clinical evidence. DBG150 was shown to be non-inferior, and subsequently superior to warfarin, for the primary outcome of all stroke/systemic embolism. DBG110 was found to be non-inferior to warfarin. Results were presented for a post hoc subgroup analysis for patients under and over 80 years of age, where DBG110 showed a statistically significant reduction of haemorrhagic stroke and intracranial haemorrhage in comparison to warfarin in patients over 80 years of age. This post hoc subgroup analysis by age was the basis for the licensed DBG sequential regimen. The economic evaluation compared the costs and outcomes of DBG110, DBG150 and DBG sequential against warfarin, aspirin, and aspirin plus clopidogrel. Across the three dosing regimens, dabigatran was associated with greater costs and better health outcomes than warfarin; however, DBG150 offered the most benefits and dominated DBG110 and DBG sequential (i.e. less costly and more effective). The cost-effectiveness of DBG150 was less favourable for patients well controlled on warfarin. In the first appraisal meeting, the committee issued a 'minded no' decision until additional analyses on the licensed DBG sequential regimen were presented by the manufacturer. These additional analyses indicated that the incremental cost-effectiveness ratio (ICER) of the DBG sequential regimen compared with warfarin ranged from £8,388 to £18,987 per quality-adjusted life year (QALY) gained depending on the level of monitoring costs assumed for warfarin. Patients on warfarin would need to be within therapeutic range 83-85 % of the time for the ICER to exceed £30,000 per additional QALY. Following consideration of the additional evidence and the responses from a large number of consultees and commentators, the committee recommended dabigatran as DBG sequential as an option for the prevention of stroke and systemic embolism in people with non-valvular AF with one or more risk factors for ischaemic stroke.
Markova, M D
2001-01-01
Nuclear matrix and intermediate filaments (NM-IF) can be isolated by sequential treatment with non-ionic detergent, high salt. and nuclease. Extracted cells are easily observed by unembedded whole-mount transmission electron microscopy. Different somatic cell types have been subjected to this procedure and retained their essential architecture. To our knowledge, this work describes the first application of NM-IF extraction to sperm. After chemical dissection the general appearance of mouse sperm cells was preserved, except for head-from-neck separation in some cases. The cell membrane, acrosome and mitochondria were not present. The nucleus showed no apparent changes and revealed no details excepting pore complexes in the posterior part. Tissue-specific cytoskeletal elements (perforatorium, postacrosomal sheath, capitulum, segmented columns, outer dense fibers, submitochondrial reticulum, annulus, and fibrous sheath) were retained, which permitted a parallel between them and intermediate filaments of somatic cells. Tail microtubules were also relatively well preserved, showing high intrinsic stability. Cell structures could be observed well, with some details in the tail even better visible than in ultrathin sections. Observation of mouse sperm whole mounts after NM-IF extraction not only revealed intermediate filament-like properties of their cytoskeletal elements but also offered an additional viewpoint to sperm ultrastructure.
Reversed Frozen Elephant Trunk Technique to Treat a Type II Thoracoabdominal Aortic Aneurysm.
Debus, E Sebastian; Kölbel, Tilo; Wipper, Sabine; Diener, Holger; Reiter, Beate; Detter, Christian; Tsilimparis, Nikolaos
2017-04-01
To describe a hybrid technique of reversed frozen elephant trunk to treat thoracoabdominal aortic aneurysms (TAAA) through an abdominal only approach. The technique is demonstrated in a 29-year-old Marfan patient with a chronic type B aortic dissection previously treated with a thoracic stent-graft who presented with a thoracoabdominal false lumen aneurysm. Through an open distal retroperitoneal approach to the abdominal aorta, a frozen elephant trunk graft was implanted over a super-stiff wire upside down with the stent-graft component in the thoracic aorta. Following deployment of the stent-graft proximally and preservation of renovisceral perfusion in a retrograde manner, the renovisceral vessels were sequentially anastomosed to the elephant trunk graft branches, thus reducing the ischemia time of the end organs. The aortic sac was then opened, and the distal part of the hybrid graft was anastomosed with a further bifurcated graft to the iliac vessels. The reversed frozen elephant trunk technique is feasible for hybrid treatment of TAAAs via an abdominal approach only. This has the benefit of substantially reducing the trauma of thoracic exposure, thus preserving major benefits of open thoracoabdominal surgery, such as the presence of short bypasses to the renovisceral vessels and reimplantation of lumbar arteries to reduce spinal cord ischemia.
Aptel, Florent; Choudhry, Reena; Stalmans, Ingeborg
2016-08-01
This study compared the efficacy, safety, and pharmacokinetics of a preservative-free latanoprost formulation to an established, benzalkonium chloride (BAK) containing formulation for the treatment of open-angle glaucoma or ocular hypertension. This was a phase II, randomized, cross-over, investigator-masked, multi-center, pilot study (NCT01494753). A total of 30 untreated adult patients (aged ≥18 years) with primary open angle glaucoma, pseudo-exfoliative glaucoma, pigmentary glaucoma, or ocular hypertension received either preservative-free or preserved latanoprost once daily in both eyes for 6 weeks, before crossing over to receive the other treatment. Efficacy (intraocular pressure [IOP] at 8 am, midday, 4 pm and 8 pm, and global efficacy assessment by investigator), safety (adverse events, ocular symptoms and global tolerance, slit lamp examination, funduscopy, visual field examination, visual acuity, and heart rate), and pharmacokinetics were assessed at Days 0, 42, and 84. Both treatments resulted in a reduction in IOP that was similar for the preservative-free and the preserved formulation at all time points. Similarly, the overall diurnal reduction was similar in both groups (6.3 mmHg [27.9% reduction] and 6.4 mmHg [28.1% reduction] for preserved and preservative-free latanoprost, respectively). There were no differences in global efficacy assessment or in the safety and tolerance of each treatment. Systemic concentrations of latanoprost were very low; AUC0-30 and Cmax were lower and tmax was longer for preservative-free latanoprost. Preservative-free latanoprost showed similar efficacy at all time points compared to BAK preservative containing formulation, with no difference in tolerance, allowing progression to phase III clinical development.
Sfontouris, Ioannis A; Kolibianakis, Efstratios M; Lainas, George T; Petsas, George K; Tarlatzis, Basil C; Lainas, Trifon G
2017-09-01
The aim of the present study was to compare blastocyst formation rates after embryo culture in a single medium (Global) as compared to sequential media (ISM1/BlastAssist). In this prospective trial with sibling oocytes, 542 metaphase II (ΜΙΙ) oocytes from 31 women were randomly and equally divided to be fertilized and cultured to the blastocyst stage in either sequential media (ISM1/BlastAssist; n = 271 MII oocytes) or a single medium (Global; n = 271 MII oocytes). In both groups, embryos were cultured in an interrupted fashion with media changes on day 3. Embryo transfer was performed on day 5. Blastocyst formation rates on day 5 (61.7% ± 19.9% vs 37.0% ± 25.5%, P < .001) were significantly higher following culture in Global as compared to ISM1/BlastAssist, respectively. Fertilization rates, cleavage rates, and percentage of good quality embryos on day 3 were similar between Global and ISM1/BlastAssist, respectively. The percentages of good quality blastocysts (63.0% ± 24.8% vs 32.1% ± 37.2%, P < .001), blastocysts selected for transfer (27.8% ± 19.2% vs 11.1% ± 14.4%, P = .005), and utilization rates (62.5% ± 24.8% vs 39.0% ± 25.2%, P < .001) were significantly higher in Global as compared to ISM1/BlastAssist, respectively. In conclusion, culture in Global was associated with higher blastocyst formation rates compared to ISM1/BlastAssist, suggesting that the single medium may provide better support to the developing embryo.
da Silva Dias, Mariana; Menezes, Camila Braz; Tasca, Tiana
2016-11-01
This study compared preservative solutions at different temperatures aiming to improve the wet mount for trichomoniasis diagnosis. The glucose-saline pH6.0 solution preserved the trophozoites up to 6h. The urine samples preservation is crucial for diagnosis and we suggest this solution as part of the clinical laboratorial routine. Copyright © 2016 Elsevier B.V. All rights reserved.
Treatability of SPF framing lumber with CCA and borate preservatives
Cherilyn Hatfield
2005-01-01
There is increasing interest in preservative pressure-treatment of framing lumber to prevent attack by decay fungi and insects. However, the Spruceâ pineâFir species group that is often used in framing construction can be difficult to penetrate with preservatives. We compared solution uptake and penetration of boron and copper from a boraxâcopper (BC) preservative to...
Sheng, Qingsong; Ma, Ning; Huang, Huijuan; Xu, Bo; He, Chunni; Song, Yanfeng
2015-01-01
Recently, increasing evidence has shown that uterus preservation is beneficial for pelvic organ prolapse (POP) patients, both physiologically and psychologically. However, the preoperative indicators for uterus preservation have rarely been examined. The current study was designed to determine the relationship between the preoperative evaluated uterus weight and the operation selection (preserving the uterus or not) in pelvic reconstructive surgery (PRS) using vaginal meshes. First, in a series of 96 patients undergoing hysterectomy, the uterine weight was calculated by preoperative ultrasound measurements, and was then compared with the postoperative actual weight of the uterus. Subsequently, in a series of 65 patients undergone PRS using vaginal meshes and preserving the uterus, the uterine weight was calculated by preoperative ultrasound measurements. Lastly, in a series of 43 patients with a uterine weight > 56.12 g who had undergone PRS using vaginal meshes, the operation success rate in patients with a preserved uterus was compared to patients for whom the uterus was not preserved. The results showed that uterus weight can be evaluated by ultrasound and used as a preoperative indicator for whether the uterus should be preserved or not in PRS when using vaginal meshes. It was indicated that preoperative evaluation of uterine weight is beneficial for surgical planning and guidance. PMID:25755793
Extremely accurate sequential verification of RELAP5-3D
Mesina, George L.; Aumiller, David L.; Buschman, Francis X.
2015-11-19
Large computer programs like RELAP5-3D solve complex systems of governing, closure and special process equations to model the underlying physics of nuclear power plants. Further, these programs incorporate many other features for physics, input, output, data management, user-interaction, and post-processing. For software quality assurance, the code must be verified and validated before being released to users. For RELAP5-3D, verification and validation are restricted to nuclear power plant applications. Verification means ensuring that the program is built right by checking that it meets its design specifications, comparing coding to algorithms and equations and comparing calculations against analytical solutions and method ofmore » manufactured solutions. Sequential verification performs these comparisons initially, but thereafter only compares code calculations between consecutive code versions to demonstrate that no unintended changes have been introduced. Recently, an automated, highly accurate sequential verification method has been developed for RELAP5-3D. The method also provides to test that no unintended consequences result from code development in the following code capabilities: repeating a timestep advancement, continuing a run from a restart file, multiple cases in a single code execution, and modes of coupled/uncoupled operation. In conclusion, mathematical analyses of the adequacy of the checks used in the comparisons are provided.« less
Gao, Xiao-Zhong; Qiao, Xiu-Li; Song, Wen-Chong; Wang, Xiao-Feng; Liu, Feng
2010-01-01
AIM: To compare the effectiveness of standard triple, bismuth pectin quadruple and sequential therapies for Helicobacter pylori (H. pylori) eradication in a randomized, double-blinded, comparative clinical trial in China. METHODS: A total of 215 H. pylori-positive patients were enrolled in the study and randomly allocated into three groups: group A (n = 72) received a 10-d bismuth pectin quadruple therapy (20 mg rabeprazole bid, 1000 mg amoxicillin bid, 100 mg bismuth pectin qid, and 500 mg levofloxacin qd); group B (n = 72) received the sequential therapy (20 mg omeprazole bid, 1000 mg amoxicillin bid, in 5 d, followed by 20 mg omeprazole bid, 500 mg tinidazole bid, 500 mg clarithromycin bid, for another 5 d); group C (n = 71) received a standard 1-wk triple therapy (20 mg omeprazole bid, 1000 mg amoxicillin bid, 500 mg clarithromycin bid). After all these treatments, 20 mg omeprazole bid was administrated for 3 wk. H. pylori status was assessed by histology, 13C-urea breath test and rapid urease test at baseline and 4-6 wk after completion of treatment. Ulcer cicatrization was assessed by gastroscopy. χ2 test (P < 0.05) was used to compare the eradication rates and ulcer cicatrisation rates among the three groups. RESULTS: The eradication rate was 83.33% (60/72) in group A, 88.89% (64/72) in group B, and 80.56% (58/71) in group C. The ulcer cicatrisation rate was 86.44% (51/59) in group A, 90.16% (55/61) in group B, and 84.91% (45/53) in group C. The sequential therapy yielded a higher eradication rate and ulcer cicatrisation rate than the standard triple and bismuth pectin quadruple therapies. Statistically, the eradication rate of group B was significantly different from groups A and C (P < 0.05), but the difference of ulcer cicatrisation rate and side effects was not statistically significant among the three groups (P > 0.05). The three protocols were generally well tolerated. CONCLUSION: The sequential therapy has achieved a significantly higher eradication rate, and is a more suitable first-line alternative protocol for anti-H. pylori infection compared with the standard triple and bismuth pectin quadruple therapies. PMID:20818821
Boessenecker, Robert W.; Perry, Frank A.; Schmitt, James G.
2014-01-01
Background Taphonomic study of marine vertebrate remains has traditionally focused on single skeletons, lagerstätten, or bonebed genesis with few attempts to document environmental gradients in preservation. As such, establishment of a concrete taphonomic model for shallow marine vertebrate assemblages is lacking. The Neogene Purisima Formation of Northern California, a richly fossiliferous unit recording nearshore to offshore depositional settings, offers a unique opportunity to examine preservational trends across these settings. Methodology/Principal Findings Lithofacies analysis was conducted to place vertebrate fossils within a hydrodynamic and depositional environmental context. Taphonomic data including abrasion, fragmentation, phosphatization, articulation, polish, and biogenic bone modification were recorded for over 1000 vertebrate fossils of sharks, bony fish, birds, pinnipeds, odontocetes, mysticetes, sirenians, and land mammals. These data were used to compare both preservation of multiple taxa within a single lithofacies and preservation of individual taxa across lithofacies to document environmental gradients in preservation. Differential preservation between taxa indicates strong preservational bias within the Purisima Formation. Varying levels of abrasion, fragmentation, phosphatization, and articulation are strongly correlative with physical processes of sediment transport and sedimentation rate. Preservational characteristics were used to delineate four taphofacies corresponding to inner, middle, and outer shelf settings, and bonebeds. Application of sequence stratigraphic methods shows that bonebeds mark major stratigraphic discontinuities, while packages of rock between discontinuities consistently exhibit onshore-offshore changes in taphofacies. Conclusions/Significance Changes in vertebrate preservation and bonebed character between lithofacies closely correspond to onshore-offshore changes in depositional setting, indicating that the dominant control of preservation is exerted by physical processes. The strong physical control on marine vertebrate preservation and preservational bias within the Purisima Formation has implications for paleoecologic and paleobiologic studies of marine vertebrates. Evidence of preservational bias among marine vertebrates suggests that careful consideration of taphonomic overprint must be undertaken before meaningful paleoecologic interpretations of shallow marine vertebrates is attempted. PMID:24626134
Boessenecker, Robert W; Perry, Frank A; Schmitt, James G
2014-01-01
Taphonomic study of marine vertebrate remains has traditionally focused on single skeletons, lagerstätten, or bonebed genesis with few attempts to document environmental gradients in preservation. As such, establishment of a concrete taphonomic model for shallow marine vertebrate assemblages is lacking. The Neogene Purisima Formation of Northern California, a richly fossiliferous unit recording nearshore to offshore depositional settings, offers a unique opportunity to examine preservational trends across these settings. Lithofacies analysis was conducted to place vertebrate fossils within a hydrodynamic and depositional environmental context. Taphonomic data including abrasion, fragmentation, phosphatization, articulation, polish, and biogenic bone modification were recorded for over 1000 vertebrate fossils of sharks, bony fish, birds, pinnipeds, odontocetes, mysticetes, sirenians, and land mammals. These data were used to compare both preservation of multiple taxa within a single lithofacies and preservation of individual taxa across lithofacies to document environmental gradients in preservation. Differential preservation between taxa indicates strong preservational bias within the Purisima Formation. Varying levels of abrasion, fragmentation, phosphatization, and articulation are strongly correlative with physical processes of sediment transport and sedimentation rate. Preservational characteristics were used to delineate four taphofacies corresponding to inner, middle, and outer shelf settings, and bonebeds. Application of sequence stratigraphic methods shows that bonebeds mark major stratigraphic discontinuities, while packages of rock between discontinuities consistently exhibit onshore-offshore changes in taphofacies. Changes in vertebrate preservation and bonebed character between lithofacies closely correspond to onshore-offshore changes in depositional setting, indicating that the dominant control of preservation is exerted by physical processes. The strong physical control on marine vertebrate preservation and preservational bias within the Purisima Formation has implications for paleoecologic and paleobiologic studies of marine vertebrates. Evidence of preservational bias among marine vertebrates suggests that careful consideration of taphonomic overprint must be undertaken before meaningful paleoecologic interpretations of shallow marine vertebrates is attempted.
Jung, Yoon Suk; Park, Chan Hyuk; Park, Jung Ho; Nam, Eunwoo; Lee, Hang Lak
2017-08-01
The efficacy of Helicobacter pylori eradication regimens may depend on the country where the studies were performed because of the difference in antibiotic resistance. We aimed to analyze the efficacy of H. pylori eradication regimens in Korea where clarithromycin resistance rate is high. We searched for all relevant randomized controlled trials published until November 2016 that investigated the efficacy of H. pylori eradication therapies in Korea. A network meta-analysis was performed to calculate the direct and indirect estimates of efficacy among the eradication regimens. Forty-three studies were identified through a systematic review, of which 34 studies, published since 2005, were included in the meta-analysis. Among 21 included regimens, quinolone-containing sequential therapy for 14 days (ST-Q-14) showed the highest eradication rate (91.4% [95% confidence interval [CI], 86.9%-94.4%] in the intention-to-treat [ITT] analysis). The eradication rate of the conventional triple therapy for 7 days, standard sequential therapy for 10 days, hybrid therapy for 10-14 days, and concomitant therapy for 10-14 days was 71.1% (95% CI, 68.3%-73.7%), 76.2% (95% CI, 72.8%-79.3%), 79.4% (95% CI, 75.5%-82.8%), and 78.3% (95% CI, 75.3%-80.9%), respectively, in the ITT analysis. In the network meta-analysis, ST-Q-14 showed a better comparative efficacy than the conventional triple therapy, standard sequential therapy, hybrid therapy, and concomitant therapy. In addition, tolerability of ST-Q-14 was comparable to those regimens. In Korea, ST-Q-14 showed the highest efficacy in terms of eradication and a comparable tolerability, compared to the results reported for the conventional triple therapy, standard sequential therapy, hybrid therapy, and concomitant therapy. © 2017 John Wiley & Sons Ltd.
Ito, Kentaro; Hataji, Osamu; Kobayashi, Hiroyasu; Fujiwara, Atsushi; Yoshida, Masamichi; D'Alessandro-Gabazza, Corina N; Itani, Hidetoshi; Tanigawa, Motoaki; Ikeda, Takuya; Fujiwara, Kentaro; Fujimoto, Hajime; Kobayashi, Tetsu; Gabazza, Esteban C; Taguchi, Osamu; Yamamoto, Nobuyuki
2017-02-01
Alectinib and crizotinib have been approved for the therapy of NSCLC caused by anaplastic lymphoma kinase gene (ALK) rearrangement. The effect of alectinib or crizotinib on overall survival (OS) in patients with ALK-rearranged NSCLC remains unknown. A multicenter retrospective study was conducted to compare OS between patients receiving alectinib and crizotinib and between patients treated with alectinib and those treated sequentially with crizotinib and then alectinib after crizotinib failure. The time to treatment failure (TTF), progression-free survival (PFS), and OS were compared. Sixty-one patients with ALK-rearranged NSCLC were enrolled. Forty-six patients were treated with anaplastic lymphoma kinase (ALK) inhibitors (31 with crizotinib, 28 with alectinib, and 13 with both ALK inhibitors). The response rate was 66.7% for the crizotinib-treated group and 80.8% for the alectinib-treated group. Among all patients, TTF and PFS were significantly prolonged in the alectinib-treated group compared with in the crizotinib-treated group. Subgroup analyses revealed significantly prolonged TTF for alectinib compared with crizotinib therapy in the ALK inhibitor-naive population. OS was significantly longer in the alectinib-treated group than in the crizotinib-treated group. The TTF and OS of patients treated sequentially with crizotinib and then with alectinib after crizotinib failure tended to be longer than those of patients treated with alectinib alone. Therapy with alectinib alone was significantly superior to therapy with crizotinib alone in terms of TTF, PFS, and OS, and sequential therapy with crizotinib and alectinib after crizotinib failure tended to provide a better OS benefit than did therapy with alectinib alone in patients with ALK-positive NSCLC. However, large-scale prospective studies are needed to confirm these observations. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
Ganapathy, Kavina; Sowmithra, Sowmithra; Bhonde, Ramesh; Datta, Indrani
2016-07-16
The neuron-glia ratio is of prime importance for maintaining the physiological homeostasis of neuronal and glial cells, and especially crucial for dopaminergic neurons because a reduction in glial density has been reported in postmortem reports of brains affected by Parkinson's disease. We thus aimed at developing an in vitro midbrain culture which would replicate a similar neuron-glia ratio to that in in vivo adult midbrain while containing a similar number of dopaminergic neurons. A sequential culture technique was adopted to achieve this. Neural progenitors (NPs) were generated by the hanging-drop method and propagated as 3D neurospheres followed by the derivation of outgrowth from these neurospheres on a chosen extracellular matrix. The highest proliferation was observed in neurospheres from day in vitro (DIV) 5 through MTT and FACS analysis of Ki67 expression. FACS analysis using annexin/propidium iodide showed an increase in the apoptotic population from DIV 8. DIV 5 neurospheres were therefore selected for deriving the differentiated outgrowth of midbrain on a poly-L-lysine-coated surface. Quantitative RT-PCR showed comparable gene expressions of the mature neuronal marker β-tubulin III, glial marker GFAP and dopaminergic marker tyrosine hydroxylase (TH) as compared to in vivo adult rat midbrain. The FACS analysis showed a similar neuron-glia ratio obtained by the sequential culture in comparison to adult rat midbrain. The yield of β-tubulin III and TH was distinctly higher in the sequential culture in comparison to 2D culture, which showed a higher yield of GFAP immunopositive cells. Functional characterization indicated that both the constitutive and inducible (KCl and ATP) release of dopamine was distinctly higher in the sequential culture than the 2D culture. Thus, the sequential culture technique succeeded in the initial enrichment of NPs in 3D neurospheres, which in turn resulted in an optimal attainment of the neuron-glia ratio on outgrowth culture from these neurospheres. © 2016 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Thamvichai, Ratchaneekorn; Huang, Liang-Chih; Ashok, Amit; Gong, Qian; Coccarelli, David; Greenberg, Joel A.; Gehm, Michael E.; Neifeld, Mark A.
2017-05-01
We employ an adaptive measurement system, based on sequential hypotheses testing (SHT) framework, for detecting material-based threats using experimental data acquired on an X-ray experimental testbed system. This testbed employs 45-degree fan-beam geometry and 15 views over a 180-degree span to generate energy sensitive X-ray projection data. Using this testbed system, we acquire multiple view projection data for 200 bags. We consider an adaptive measurement design where the X-ray projection measurements are acquired in a sequential manner and the adaptation occurs through the choice of the optimal "next" source/view system parameter. Our analysis of such an adaptive measurement design using the experimental data demonstrates a 3x-7x reduction in the probability of error relative to a static measurement design. Here the static measurement design refers to the operational system baseline that corresponds to a sequential measurement using all the available sources/views. We also show that by using adaptive measurements it is possible to reduce the number of sources/views by nearly 50% compared a system that relies on static measurements.
Button, Le; Peter, Beate; Stoel-Gammon, Carol; Raskind, Wendy H
2013-03-01
The purpose of this study was to address the hypothesis that childhood apraxia of speech (CAS) is influenced by an underlying deficit in sequential processing that is also expressed in other modalities. In a sample of 21 adults from five multigenerational families, 11 with histories of various familial speech sound disorders, 3 biologically related adults from a family with familial CAS showed motor sequencing deficits in an alternating motor speech task. Compared with the other adults, these three participants showed deficits in tasks requiring high loads of sequential processing, including nonword imitation, nonword reading and spelling. Qualitative error analyses in real word and nonword imitations revealed group differences in phoneme sequencing errors. Motor sequencing ability was correlated with phoneme sequencing errors during real word and nonword imitation, reading and spelling. Correlations were characterized by extremely high scores in one family and extremely low scores in another. Results are consistent with a central deficit in sequential processing in CAS of familial origin.
Härkönen, Kati; Kivekäs, Ilkka; Rautiainen, Markus; Kotti, Voitto; Sivonen, Ville; Vasama, Juha-Pekka
2015-05-01
This prospective study shows that working performance, quality of life (QoL), and quality of hearing (QoH) are better with two compared with a single cochlear implant (CI). The impact of the second CI on the patient's QoL is as significant as the impact of the first CI. To evaluate the benefits of sequential bilateral cochlear implantation in working, QoL, and QoH. We studied working performance, work-related stress, QoL, and QoH with specific questionnaires in 15 patients with unilateral CI scheduled for sequential CI of another ear. Sound localization performance and speech perception in noise were measured with specific tests. All questionnaires and tests were performed before the second CI surgery and 6 and 12 months after its activation. Bilateral CIs increased patients' working performance and their work-related stress and fatigue decreased. Communication with co-workers was easier and patients were more active in their working environment. Sequential bilateral cochlear implantation improved QoL, QoH, sound localization, and speech perception in noise statistically significantly.
Sequential ASE extraction of alkylphenols from sediments: Occurrence and environmental implications.
Gong, Jian; Xu, Lei; Yang, Yu; Chen, Di-Yun; Ran, Yong
2011-08-30
The occurrence of alkylphenols (APs) including nonylphenol (NP) and octylphenol (OP) in the riverine sediments from the Pearl River Delta (PRD), South China was investigated and compared by Soxhlet extraction (S-APs) with dichloromethane and by sequential accelerated solvent extraction (ASE) (A-APs) with 1:6 toluene/methanol, respectively. Concentrations of OP and NP range from <1 to 463ng/g dw and 31-21,885ng/g dw, respectively, demonstrating that the contamination level of APs in the PRD is one of the highest in the world. Moreover, the A-APs contents are highly significantly related to and on average 1.5 times the S-APs contents. For sequential two ASE extractions, APs in the first extract accounts for 82.2-99.2% of their total contents in the sequential two extractions. The correlation analysis shows that S-APs and A-APs are both significantly associated with the contents of total organic carbon (TOC), suggesting that the variable extraction efficiency of these two methods is related to the presence of condensed organic matter in the sediments. Copyright © 2011 Elsevier B.V. All rights reserved.
Sedano-Portillo, Ismael; Ochoa-León, Gastón; Fuentes-Orozco, Clotilde; Irusteta-Jiménez, Leire; Michel-Espinoza, Luis Rodrigo; Salazar-Parra, Marcela; Cuesta-Márquez, Lizbeth; González-Ojeda, Alejandro
2017-01-01
Percutaneous nephrolithotomy is an efficient approach for treatment of different types of kidney stones. Various types of access techniques have been described like sequential dilatation and one-shot procedure. To determine the differences in time of exposure to X-rays and hemoglobin levels between techniques. Controlled clinical trial. Patients older than 18 years with complex/uncomplicated kidney stones, without urine infection were included. They were assigned randomly to one of the two techniques. Response variables were determined before and 24 h after procedures. 59 patients were included: 30 underwent one-shot procedure (study-group) and 29 sequential dilatation (control-group). Baseline characteristics were similar. Study group had a lower postoperative hemoglobin decline than control group (0.81 vs. 2.03 g/dl, respectively; p < 0.001); X-ray exposure time (69.6 vs. 100.62 s; p < 0.001) and postoperative creatinine serum levels (0.93 ± 0.29 vs. 1.13 ± 0.4 mg/dl; p = 0.039). No significant differences in postoperative morbidity were found. One-shot technique demonstrated better results compared to sequential dilatation.
Treatment of mites folliculitis with an ornidazole-based sequential therapy
Luo, Yang; Sun, Yu-Jiao; Zhang, Li; Luan, Xiu-Li
2016-01-01
Abstract Objective: Treatment of Demodex infestations is often inadequate and associated with low effective rate. We sought to evaluate the efficacy of an ornidazole-based sequential therapy for mites folliculitis treatment. Methods: Two-hundred patients with mites folliculitis were sequentially treated with either an ornidazole- or metronidazole-based regimen. Sebum cutaneum was extruded from the sebaceous glands of each patient's nose and the presence of Demodex mites were examined by light microscopy. The clinical manifestations of relapse of mites folliculitis were recorded and the subjects were followed up at 2, 4, 8, and 12 weeks post-treatment. Results: Patients treated with the ornidazole-based regimen showed an overall effective rate of 94.0%. Additionally, at the 2, 4, 8, and 12-week follow-up, these patients had significantly lower rates of Demodex mite relapse and new lesion occurrence compared with patients treated with the metronidazole-based regimen (P < 0.05). Conclusion: Sequential therapy using ornidazole, betamethasone, and recombinant bovine basic fibroblast growth factor (rbFGF) gel is highly effective for treating mites folliculitis. PMID:27399141
BUTTON, LE; PETER, BEATE; STOEL-GAMMON, CAROL; RASKIND, WENDY H.
2013-01-01
The purpose of this study was to address the hypothesis that childhood apraxia of speech (CAS) is influenced by an underlying deficit in sequential processing that is also expressed in other modalities. In a sample of 21 adults from five multigenerational families, 11 with histories of various familial speech sound disorders, 3 biologically related adults from a family with familial CAS showed motor sequencing deficits in an alternating motor speech task. Compared with the other adults, these three participants showed deficits in tasks requiring high loads of sequential processing, including nonword imitation, nonword reading and spelling. Qualitative error analyses in real word and nonword imitations revealed group differences in phoneme sequencing errors. Motor sequencing ability was correlated with phoneme sequencing errors during real word and nonword imitation, reading and spelling. Correlations were characterized by extremely high scores in one family and extremely low scores in another. Results are consistent with a central deficit in sequential processing in CAS of familial origin. PMID:23339292
CACTI: Free, Open-Source Software for the Sequential Coding of Behavioral Interactions
Glynn, Lisa H.; Hallgren, Kevin A.; Houck, Jon M.; Moyers, Theresa B.
2012-01-01
The sequential analysis of client and clinician speech in psychotherapy sessions can help to identify and characterize potential mechanisms of treatment and behavior change. Previous studies required coding systems that were time-consuming, expensive, and error-prone. Existing software can be expensive and inflexible, and furthermore, no single package allows for pre-parsing, sequential coding, and assignment of global ratings. We developed a free, open-source, and adaptable program to meet these needs: The CASAA Application for Coding Treatment Interactions (CACTI). Without transcripts, CACTI facilitates the real-time sequential coding of behavioral interactions using WAV-format audio files. Most elements of the interface are user-modifiable through a simple XML file, and can be further adapted using Java through the terms of the GNU Public License. Coding with this software yields interrater reliabilities comparable to previous methods, but at greatly reduced time and expense. CACTI is a flexible research tool that can simplify psychotherapy process research, and has the potential to contribute to the improvement of treatment content and delivery. PMID:22815713
Kremers, Stef PJ; Vandelanotte, Corneel; van Adrichem, Mathieu JG; Schneider, Francine; Candel, Math JJM; de Vries, Hein
2014-01-01
Background Web-based computer-tailored interventions for multiple health behaviors can have a significant public health impact. Yet, few randomized controlled trials have tested this assumption. Objective The objective of this paper was to test the effects of a sequential and simultaneous Web-based tailored intervention on multiple lifestyle behaviors. Methods A randomized controlled trial was conducted with 3 tailoring conditions (ie, sequential, simultaneous, and control conditions) in the Netherlands in 2009-2012. Follow-up measurements took place after 12 and 24 months. The intervention content was based on the I-Change model. In a health risk appraisal, all respondents (N=5055) received feedback on their lifestyle behaviors that indicated whether they complied with the Dutch guidelines for physical activity, vegetable consumption, fruit consumption, alcohol intake, and smoking. Participants in the sequential (n=1736) and simultaneous (n=1638) conditions received tailored motivational feedback to change unhealthy behaviors one at a time (sequential) or all at the same time (simultaneous). Mixed model analyses were performed as primary analyses; regression analyses were done as sensitivity analyses. An overall risk score was used as outcome measure, then effects on the 5 individual lifestyle behaviors were assessed and a process evaluation was performed regarding exposure to and appreciation of the intervention. Results Both tailoring strategies were associated with small self-reported behavioral changes. The sequential condition had the most significant effects compared to the control condition after 12 months (T1, effect size=0.28). After 24 months (T2), the simultaneous condition was most effective (effect size=0.18). All 5 individual lifestyle behaviors changed over time, but few effects differed significantly between the conditions. At both follow-ups, the sequential condition had significant changes in smoking abstinence compared to the simultaneous condition (T1 effect size=0.31; T2 effect size=0.41). The sequential condition was more effective in decreasing alcohol consumption than the control condition at 24 months (effect size=0.27). Change was predicted by the amount of exposure to the intervention (total visiting time: beta=–.06; P=.01; total number of visits: beta=–.11; P<.001). Both interventions were appreciated well by respondents without significant differences between conditions. Conclusions Although evidence was found for the effectiveness of both programs, no simple conclusive finding could be drawn about which intervention mode was more effective. The best kind of intervention may depend on the behavior that is targeted or on personal preferences and motivation. Further research is needed to identify moderators of intervention effectiveness. The results need to be interpreted in view of the high and selective dropout rates, multiple comparisons, and modest effect sizes. However, a large number of people were reached at low cost and behavioral change was achieved after 2 years. Trial Registration Nederlands Trial Register: NTR 2168; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2168 (Archived by WebCite at http://www.webcitation.org/6MbUqttYB). PMID:24472854
Klein, Sabine D; Wolf, Ursula
2016-02-01
Homeopathic globules are commonly used in clinical practice, while research focuses on liquid potencies. Sequential dilution and succussion in their production process has been proposed to change the physico-chemical properties of the solvent(s). It has been reported that aqueous potencies of various starting materials showed significant differences in ultraviolet light transmission compared to controls and between different dilution levels. The aim of the present study was to repeat and expand these experiments to homeopathic globules. Globules were specially produced for this study by Spagyros AG (Gümligen, Switzerland) from 6 starting materials (Aconitum napellus, Atropa belladonna, phosphorus, sulfur, Apis mellifica, quartz) and for 6 dilution levels (6x, 12x, 30c, 200c, 200CF (centesimal discontinuous fluxion), 10,000CF). Native globules and globules impregnated with solvents were used as controls. Globules were dissolved in ultrapure water, and absorbance in the ultraviolet range was measured. The average absorbance from 200 to 340nm was calculated and corrected for differences between measurement days and instrumental drift. Statistically significant differences were found for A. napellus, sulfur, and A. mellifica when normalized average absorbance of the various dilution levels from the same starting material (including control and solvent control globules) was compared. Additionally, absorbance within dilution levels was compared among the various starting materials. Statistically significant differences were found among 30c, 200c and 200CF dilutions. This study has expanded previous findings from aqueous potencies to globules and may indicate that characteristics of aqueous high dilutions may be preserved and detectable in dissolved globules. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Oza, D. H.; Jones, T. L.; Feiertag, R.; Samii, M. V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.
The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite (TDRS) System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the May 18-24, 1992, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. During this period, there were two separate orbit-adjust maneuvers on one of the TDRSS spacecraft (TDRS-East) and one small orbit-adjust maneuver for Landsat-4. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 30 meters after the filter had reached steady state.
Sequential or parallel decomposed processing of two-digit numbers? Evidence from eye-tracking.
Moeller, Korbinian; Fischer, Martin H; Nuerk, Hans-Christoph; Willmes, Klaus
2009-02-01
While reaction time data have shown that decomposed processing of two-digit numbers occurs, there is little evidence about how decomposed processing functions. Poltrock and Schwartz (1984) argued that multi-digit numbers are compared in a sequential digit-by-digit fashion starting at the leftmost digit pair. In contrast, Nuerk and Willmes (2005) favoured parallel processing of the digits constituting a number. These models (i.e., sequential decomposition, parallel decomposition) make different predictions regarding the fixation pattern in a two-digit number magnitude comparison task and can therefore be differentiated by eye fixation data. We tested these models by evaluating participants' eye fixation behaviour while selecting the larger of two numbers. The stimulus set consisted of within-decade comparisons (e.g., 53_57) and between-decade comparisons (e.g., 42_57). The between-decade comparisons were further divided into compatible and incompatible trials (cf. Nuerk, Weger, & Willmes, 2001) and trials with different decade and unit distances. The observed fixation pattern implies that the comparison of two-digit numbers is not executed by sequentially comparing decade and unit digits as proposed by Poltrock and Schwartz (1984) but rather in a decomposed but parallel fashion. Moreover, the present fixation data provide first evidence that digit processing in multi-digit numbers is not a pure bottom-up effect, but is also influenced by top-down factors. Finally, implications for multi-digit number processing beyond the range of two-digit numbers are discussed.
NASA Technical Reports Server (NTRS)
Oza, D. H.; Jones, T. L.; Feiertag, R.; Samii, M. V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.
1993-01-01
The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite (TDRS) System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the May 18-24, 1992, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. During this period, there were two separate orbit-adjust maneuvers on one of the TDRSS spacecraft (TDRS-East) and one small orbit-adjust maneuver for Landsat-4. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 30 meters after the filter had reached steady state.
Lin, Lien-Chieh; Hsu, Tzu-Herng; Huang, Kuang-Wei; Tam, Ka-Wai
2016-01-01
AIM: To evaluate the applicability of nonbismuth concomitant quadruple therapy for Helicobacter pylori (H. pylori) eradication in Chinese regions. METHODS: A systematic review and meta-analysis of randomized controlled trials was performed to evaluate the efficacy of nonbismuth concomitant quadruple therapy between sequential therapy or triple therapy for H. pylori eradication in Chinese regions. The defined Chinese regions include China, Hong Kong, Taiwan, and Singapore. The primary outcome was the H. pylori eradication rate; the secondary outcome was the compliance with therapy. The PubMed, Embase, Scopus, and Cochrane databases were searched for studies published in the period up to March 2016 with no language restriction. RESULTS: We reviewed six randomized controlled trials and 1616 patients. In 3 trials comparing concomitant quadruple therapy with triple therapy, the H. pylori eradication rate was significantly higher for 7-d nonbismuth concomitant quadruple therapy than for 7-d triple therapy (91.2% vs 77.9%, risk ratio = 1.17, 95%CI: 1.09-1.25). In 3 trials comparing quadruple therapy with sequential therapy, the eradication rate was not significant between groups (86.9% vs 86.0%). However, higher compliance was achieved with concomitant therapy than with sequential therapy. CONCLUSION: The H. pylori eradication rate was higher for nonbismuth concomitant quadruple therapy than for triple therapy. Moreover, higher compliance was achieved with nonbismuth concomitant quadruple therapy than with sequential therapy. Thus, nonbismuth concomitant quadruple therapy should be the first-line treatment in Chinese regions. PMID:27340362
NASA Astrophysics Data System (ADS)
Izzati, Munifatul; Haryanti, Sri; Parman, Sarjana
2018-05-01
Gracilaria widely known as a source of essential trace elements. However this red seaweeds also has great potential for being developed into commercial products. This study examined the sequential pattern of essential trace elements composition in fresh Gracilaria verrucosa and a selection of its generated products, nemely extracted agar, Gracilaria salt and Gracilaria residue. The sample was collected from a brackish water pond, located in north part Semarang, Central Java. The collected sample was then dried under the sun, and subsequently processed into aformentioned generated products. The Gracilaria salt was obtain by soaking the sun dried Gracilaria overnight in fresh water overnight. The resulted salt solution was then boiled leaving crystal salt. Extracted agar was obtained with alkali agar extraction method. The rest of remaining material was considered as Gracilaria residue. The entire process was repeated 3 times. The compositin of trace elements was examined using ICP-MS Spectrometry. Collected data was then analyzed by ANOVA single factor. Resulting sequential pattern of its essential trace elements composition was compared. A regular table salt was used as controls. Resuts from this study revealed that Gracilaria verrucosa and its all generated products all have similarly patterned the composition of essential trace elements, where Mn>Zn>Cu>Mo. Additionally this pattern is similar to different subspecies of Gracilaria from different location and and different season. However, Gracilaria salt has distinctly different pattern of sequential essential trace elements composition compared to table salt.
Immediately sequential bilateral cataract surgery: advantages and disadvantages.
Singh, Ranjodh; Dohlman, Thomas H; Sun, Grace
2017-01-01
The number of cataract surgeries performed globally will continue to rise to meet the needs of an aging population. This increased demand will require healthcare systems and providers to find new surgical efficiencies while maintaining excellent surgical outcomes. Immediately sequential bilateral cataract surgery (ISBCS) has been proposed as a solution and is increasingly being performed worldwide. The purpose of this review is to discuss the advantages and disadvantages of ISBCS. When appropriate patient selection occurs and guidelines are followed, ISBCS is comparable with delayed sequential bilateral cataract surgery in long-term patient satisfaction, visual acuity and complication rates. In addition, the risk of bilateral postoperative endophthalmitis and concerns of poorer refractive outcomes have not been supported by the literature. ISBCS is cost-effective for the patient, healthcare payors and society, but current reimbursement models in many countries create significant financial barriers for facilities and surgeons. As demand for cataract surgery rises worldwide, ISBCS will become increasingly important as an alternative to delayed sequential bilateral cataract surgery. Advantages include potentially decreased wait times for surgery, patient convenience and cost savings for healthcare payors. Although they are comparable in visual acuity and complication rates, hurdles that prevent wide adoption include liability concerns as ISBCS is not an established standard of care, economic constraints for facilities and surgeons and inability to fine-tune intraocular lens selection in the second eye. Given these considerations, an open discussion regarding the advantages and disadvantages of ISBCS is important for appropriate patient selection.
Witt, E. C.; Hippe, D.J.; Giovannitti, R.M.
1992-01-01
A total of 304 nutrient samples were collected from May 1990 through September 1991 to determine concentrations and loads of nutrients in water discharged from two spring basins in Cumberland County, Pa. Fifty-four percent of these nutrient samples were for the evaluation of (1) laboratory consistency, (2) container and preservative cleanliness, (3) maintenance of analyte representativeness as affected by three different preservation methods, and (4) comparison of analyte results with the "Most Probable Value" for Standard Reference Water Samples. Results of 37 duplicate analyses indicate that the Pennsylvania Department of Environmental Resources, Bureau of Laboratories (principal laboratory) remained within its ±10 percent goal for all but one analyte. Results of the blank analysis show that the sampling containers did not compromise the water quality. However, mercuric-chloride-preservation blanks apparently contained measurable ammonium in four of five samples and ammonium plus organic nitrogen in two of five samples. Interlaboratory results indicate substantial differences in the determination of nitrate and ammonium plus organic nitrogen between the principal laboratory and the U.S. Geological Survey National Water-Quality Laboratory. In comparison with the U.S. Environmental Protection Agency Quality-Control Samples, the principal laboratory was sufficiently accurate in its determination of nutrient anafytes. Analysis of replicate samples indicated that sulfuric-acid preservative best maintained the representativeness of the anafytes nitrate and ammonium plus organic nitrogen, whereas, mercuric chloride best maintained the representativeness of orthophosphate. Comparison of nutrient analyte determinations with the Most Probable Value for each preservation method shows that two of five analytes with no chemical preservative compare well, three of five with mercuric-chloride preservative compare well, and three of five with sulfuricacid preservative compare well.
Lackey, Kimberly A; Williams, Janet E; Price, William J; Carrothers, Janae M; Brooker, Sarah L; Shafii, Bahman; McGuire, Mark A; McGuire, Michelle K
2017-10-01
Inhibiting changes to bacteria in human milk between sample collection and analysis is necessary for unbiased characterization of the milk microbiome. Although cold storage is considered optimal, alternative preservation is sometimes necessary. The objective of this study was to compare the effectiveness of several commercially-available preservatives with regard to maintaining bacterial DNA in human milk for delayed microbiome analysis. Specifically, we compared Life Technologies' RNAlater® stabilization solution, Biomatrica's DNAgard® Saliva, Advanced Instruments' Broad Spectrum Microtabs II™, and Norgen Biotek Corporation's Milk DNA Preservation and Isolation Kit. Aliquots of 8 pools of human milk were treated with each preservative. DNA was extracted immediately and at 1, 2, 4, and 6wk, during which time milk was held at 37°C. The V1-V3 region of the bacterial 16S rRNA gene was amplified and sequenced. Changes in bacterial community structure and diversity over time were evaluated. Comparable to other studies, the most abundant genera were Streptococcus (33.3%), Staphylococcus (14.0%), Dyella (6.3%), Pseudomonas (3.0%), Veillonella (2.5%), Hafnia (2.0%), Prevotella (1.7%), Rhodococcus (1.6%), and Granulicatella (1.4%). Overall, use of Norgen's Milk DNA Preservation and Isolation Kit best maintained the consistency of the bacterial community structure. Total DNA, diversity, and evenness metrics were also highest in samples preserved with this method. When collecting human milk for bacterial community analysis in field conditions where cold storage is not available, our results suggest that Norgen's Milk DNA Preservation and Isolation Kit may be a useful method, at least for a period of 2weeks. Copyright © 2017 Elsevier B.V. All rights reserved.
Sequential Voluntary Cough and Aspiration or Aspiration Risk in Parkinson’s Disease
Hegland, Karen Wheeler; Okun, Michael S.; Troche, Michelle S.
2015-01-01
Background Disordered swallowing, or dysphagia, is almost always present to some degree in people with Parkinson’s disease (PD), either causing aspiration or greatly increasing the risk for aspiration during swallowing. This likely contributes to aspiration pneumonia, a leading cause of death in this patient population. Effective airway protection is dependent upon multiple behaviors, including cough and swallowing. Single voluntary cough function is disordered in people with PD and dysphagia. However, the appropriate response to aspirate material is more than one cough, or sequential cough. The goal of this study was to examine voluntary sequential coughing in people with PD, with and without dysphagia. Methods Forty adults diagnosed with idiopathic PD produced two trials of sequential voluntary cough. The cough airflows were obtained using pneumotachograph and facemask and subsequently digitized and recorded. All participants received a modified barium swallow study as part of their clinical care, and the worst penetration–aspiration score observed was used to determine whether the patient had dysphagia. Results There were significant differences in the compression phase duration, peak expiratory flow rates, and amount of air expired of the sequential cough produced by participants with and without dysphagia. Conclusions The presence of dysphagia in people with PD is associated with disordered cough function. Sequential cough, which is important in removing aspirate material from large- and smaller-diameter airways, is also impaired in people with PD and dysphagia compared with those without dysphagia. There may be common neuroanatomical substrates for cough and swallowing impairment in PD leading to the co-occurrence of these dysfunctions. PMID:24792231
Research on parallel algorithm for sequential pattern mining
NASA Astrophysics Data System (ADS)
Zhou, Lijuan; Qin, Bai; Wang, Yu; Hao, Zhongxiao
2008-03-01
Sequential pattern mining is the mining of frequent sequences related to time or other orders from the sequence database. Its initial motivation is to discover the laws of customer purchasing in a time section by finding the frequent sequences. In recent years, sequential pattern mining has become an important direction of data mining, and its application field has not been confined to the business database and has extended to new data sources such as Web and advanced science fields such as DNA analysis. The data of sequential pattern mining has characteristics as follows: mass data amount and distributed storage. Most existing sequential pattern mining algorithms haven't considered the above-mentioned characteristics synthetically. According to the traits mentioned above and combining the parallel theory, this paper puts forward a new distributed parallel algorithm SPP(Sequential Pattern Parallel). The algorithm abides by the principal of pattern reduction and utilizes the divide-and-conquer strategy for parallelization. The first parallel task is to construct frequent item sets applying frequent concept and search space partition theory and the second task is to structure frequent sequences using the depth-first search method at each processor. The algorithm only needs to access the database twice and doesn't generate the candidated sequences, which abates the access time and improves the mining efficiency. Based on the random data generation procedure and different information structure designed, this paper simulated the SPP algorithm in a concrete parallel environment and implemented the AprioriAll algorithm. The experiments demonstrate that compared with AprioriAll, the SPP algorithm had excellent speedup factor and efficiency.
Preservation of corals in salt-saturated DMSO buffer is superior to ethanol for PCR experiments
NASA Astrophysics Data System (ADS)
Gaither, M. R.; Szabó, Z.; Crepeau, M. W.; Bird, C. E.; Toonen, R. J.
2011-06-01
Specimen collection is time consuming and expensive, yet few laboratories test preservation methods before setting out on field expeditions. The most common preservation buffer used for coral specimens is >70% EtOH. However, alternatives exist that are less flammable, easier to ship, and are widely used in other taxa. Here, we compare the effects of salt-saturated DMSO (SSD) and EtOH preservation buffers on post-extraction DNA quantity and quality. We found that soft tissue integrity was better maintained and higher quantities of DNA were extracted from EtOH-preserved specimens; however, by all other measures, SSD was a superior preservative to EtOH. Extractions of SSD-preserved specimens resulted in higher molecular weight DNA, higher PCR success, and more efficient amplification than specimens preserved in EtOH. Our results show that SSD is generally a superior preservative to EtOH for specimens destined for PCR studies, but species-specific differences indicate that preservation comparisons should be undertaken before collection and storage of samples.
Kalenski, Julia; Mancina, Elina; Paschenda, Pascal; Beckers, Christian; Bleilevens, Christian; Tóthová, Ľubomíra; Boor, Peter; Gross, Dominik; Tolba, René H; Doorschodt, Benedict M
2016-01-01
The global shortage of donor organs for transplantation has necessitated the expansion of the organ pool through increased use of organs from less ideal donors. Venous systemic oxygen persufflation (VSOP) and oxygenated machine perfusion (OMP) have previously demonstrated beneficial results compared to cold storage (CS) in the preservation of warm-ischemia-damaged kidney grafts. The aim of this study was to compare the efficacy of VSOP and OMP for the preservation of warm-ischemia-damaged porcine kidneys using the recently introduced Ecosol preservation solution compared to CS using Ecosol or histidine-tryptophan-ketoglutarate solution (HTK). Kidneys from German Landrace pigs (n = 5/group) were retrieved and washed out with either Ecosol or HTK after 45 min of clamping of the renal pedicle. As controls, kidneys without warm ischemia, cold stored for 24 h in HTK, were employed. Following 24 h of preservation by VSOP, OMP, CS-Ecosol, or CS-HTK, renal function and damage were assessed during 1 h using the isolated perfused porcine kidney model. During reperfusion, urine production was significantly higher in the VSOP and OMP groups than in the CS-HTK group; however, only VSOP could demonstrate lower urine protein concentrations and fractional excretion of sodium, which did not differ from the non-warm-ischemia-damaged control group. VSOP, CS-Ecosol, and controls showed better maintenance of the acid-base balance than CS-HTK. Reduced lipid peroxidation, as reflected in postreperfusion tissue thiobarbituric acid-reactive substance levels, was observed in the VSOP group compared to the OMP group, and the VSOP and CS-Ecosol groups had concentrations similar to the controls. The ratio of reduced to oxidized glutathione was higher in the VSOP, OMP, and CS-Ecosol groups than in the CS-HTK group and controls, with a higher ratio in the VSOP than in the OMP group. VSOP was associated with mitigation of oxidative stress in comparison to OMP and CS. Preservation of warm-ischemia-damaged porcine kidneys by VSOP was improved compared to OMP and CS, and was comparable to preservation of non-warm-ischemia-damaged cold-stored kidneys. © 2016 S. Karger AG, Basel.
Nelson, Brian A; Ritenour, Rusty J
2014-02-01
To evaluate endothelial cell density (ECD) of eye-bank-prepared tissue for use in Descemet's stripping automated endothelial keratoplasty (DSAEK). Prospective case series of consecutive corneal tissue prepared for DSAEK surgery. Sixty-seven sequential corneal-scleral tissue specimens representing 48 human donors processed for use in DSAEK surgery by the Regional Tissue Bank (Halifax, Nova Scotia). Corneal-scleral donor tissue was obtained by in situ recovery. ECD was recorded using the EB-3000 XYZ (HAI Laboratories Inc, Lexington, MA) specular microscope within 24 hours of preservation. Before the tissue was dissected, the corneal thickness was measured using the DGH-550 PACHETTE 2 (DGH Technology, Exton, PA) ultrasound pachymeter. The dissection was performed using a 300-μm Moria ALTK model microkeratome (Moria Inc). The posterior bed thickness was measured, and the anterior flap was replaced. Endothelial cell count density was obtained after re-preservation. Complete measurements were obtained for 42 of 67 corneas. In 25 corneas it was not possible to obtain a postdissection ECD measurement. The mean ECD before dissection was 2806 ± 317 cells/mm(2). The mean ECD after dissection was 2772 ± 318 cells/mm(2). There was an average loss of 34 cells/mm(2) (95% CI -110 to 40 cells/mm(2), p = 0.3). This case series confirms that ECD is preserved when DSAEK tissue is prepared in advance of surgery by trained eye-bank technicians in a low-volume Canadian eye bank. It was difficult to obtain clear images of the endothelial cell layer postdissection, possibly because of tissue swelling or distortion. Sixty-six of 67 corneas included in the study were used for surgery. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.
Real-Time Noninvasive Assessment of Pancreatic ATP Levels During Cold Preservation
Scott, W.E.; Matsumoto, S.; Tanaka, T.; Avgoustiniatos, E.S.; Graham, M.L.; Williams, P.C.; Tempelman, L.A.; Sutherland, D.E.; Hering, B.J.; Hammer, B.E.; Papas, K.K.
2008-01-01
31P-NMR spectroscopy was utilized to investigate rat and porcine pancreatic ATP:Pi ratios to assess the efficacy of existing protocols for cold preservation (CP) in maintaining organ quality. Following sacrifice, rat pancreata were immediately excised or left enclosed in the body for 15 minutes of warm ischemia (WI). After excision, rat pancreata were stored at 6°C to 8°C using histidine-tryptophan-ketoglutarate solution (HTK) presaturated with air (S1), HTK presaturated with O2 (S2), or the HTK/perfluorodecalin two-layer method (TLM) with both liquids presaturated with O2 (S3). 31P-NMR spectra were sequentially collected at 3, 6, 9, 12, and 24 hours of CP from pancreata stored with each of the three protocols examined. The ATP:Pi ratio for rat pancreata exposed to 15 minutes of WI and stored with S3 increased during the first 9 hours of CP, approaching values observed for organs procured with no WI. A marked reduction in the ATP:Pi ratio was observed beyond 12 hours of CP with S3. After 6 hours of CP, the ATP:Pi ratio was highest for S3, substantially decreased for S2, and below detection for S1. In sharp contrast to the rat model, ATP was barely detectable in porcine pancreata exposed to minimal warm ischemia (<15 minutes) stored with the TLM regardless of CP time. We conclude that 31P-NMR spectroscopy is a powerful tool that can be used to (1) noninvasively evaluate pancreata prior to islet isolation, (2) assess the efficacy of different preservation protocols, (3) precisely define the timing of reversible versus irreversible damage, and (4) assess whether intervention will extend this timing. PMID:18374082
Effect of metaphorical verbal instruction on modeling of sequential dance skills by young children.
Sawada, Misako; Mori, Shiro; Ishii, Motonobu
2002-12-01
Metaphorical verbal instruction was compared to specific verbal instruction about movement in the modeling of sequential dance skills by young children. Two groups of participants (Younger, mean age 5:3 yr., n = 30: Older, mean age 6:2 yr., n = 30) were randomly assigned to conditions in a 2 (sex) x 2 (age [Younger and Older]) x 3 (verbal instruction [Metaphorical, Movement-relevant, and None]) factorial design. Order scores were calculated for both performance and recognition tests, comprising five acquisition trials and two retention trials after 24 hr., respectively. Analysis of variance indicated that the group given metaphorical instruction performed better than the other two instructions for both younger and older children. The results suggest that metaphorical verbal instruction aids the recognition and performance of sequential dance skills in young children.
NASA Technical Reports Server (NTRS)
Oza, D. H.; Jones, T. L.; Hodjatzadeh, M.; Samii, M. V.; Doll, C. E.; Hart, R. C.; Mistretta, G. D.
1991-01-01
The development of the Real-Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination on a Disk Operating System (DOS) based Personal Computer (PC) is addressed. The results of a study to compare the orbit determination accuracy of a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOD/E with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), is addressed. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for the Earth Radiation Budget Satellite (ERBS); the maximum solution differences were less than 25 m after the filter had reached steady state.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klasson, K.T.; Abramowicz, D.A.
The Cooperative Research and Development Agreement was signed between Oak Ridge National Laboratory (ORNL) and General Electric Company (GE) on August 12, 1991. The objective was a collaborative venture between researchers at GE and ORNL to develop bioremediation of polychlorinated biphenyls (PCBs). The work was conducted over three years, and this report summarizes ORNL`s effort. It was found that the total concentration of PCBs decreased by 70% for sequential anaerobic-aerobic treatment compared with a 67% decrease for aerobic treatment alone. The sequential treatment resulted in PCB products with fewer chlorines and shorter halflives in humans compared with either anaerobic ormore » aerobic treatment alone. The study was expected to lead to a technology applicable to a field experiment that would be performed on a DOE contaminated site.« less
Vandelanotte, Corneel; De Bourdeaudhuij, Ilse; Sallis, James F; Spittaels, Heleen; Brug, Johannes
2005-04-01
Little evidence exists about the effectiveness of "interactive" computer-tailored interventions and about the combined effectiveness of tailored interventions on physical activity and diet. Furthermore, it is unknown whether they should be executed sequentially or simultaneously. The purpose of this study was to examine (a) the effectiveness of interactive computer-tailored interventions for increasing physical activity and decreasing fat intake and (b) which intervening mode, sequential or simultaneous, is most effective in behavior change. Participants (N = 771) were randomly assigned to receive (a) the physical activity and fat intake interventions simultaneously at baseline, (b) the physical activity intervention at baseline and the fat intake intervention 3 months later, (c) the fat intake intervention at baseline and the physical activity intervention 3 months later, or (d) a place in the control group. Six months postbaseline, the results showed that the tailored interventions produced significantly higher physical activity scores, F(2, 573) = 11.4, p < .001, and lower fat intake scores, F(2, 565) = 31.4, p < .001, in the experimental groups when compared to the control group. For both behaviors, the sequential and simultaneous intervening modes showed to be effective; however, for the fat intake intervention and for the participants who did not meet the recommendation in the physical activity intervention, the simultaneous mode appeared to work better than the sequential mode.
Dave, Hreem; Phoenix, Vidya; Becker, Edmund R.; Lambert, Scott R.
2015-01-01
OBJECTIVES To compare the incidence of adverse events, visual outcomes and economic costs of sequential versus simultaneous bilateral cataract surgery for infants with congenital cataracts. METHODS We retrospectively reviewed the incidence of adverse events, visual outcomes and medical payments associated with simultaneous versus sequential bilateral cataract surgery for infants with congenital cataracts who underwent cataract surgery when 6 months of age or younger at our institution. RESULTS Records were available for 10 children who underwent sequential surgery at a mean age of 49 days for the first eye and 17 children who underwent simultaneous surgery at a mean age of 68 days (p=.25). We found a similar incidence of adverse events between the two treatment groups. Intraoperative or postoperative complications occurred in 14 eyes. The most common postoperative complication was glaucoma. No eyes developed endophthalmitis. The mean absolute interocular difference in logMAR visual acuities between the two treatment groups was 0.47±0.76 for the sequential group and 0.44±0.40 for the simultaneous group (p=.92). Hospital, drugs, supplies and professional payments were on average 21.9% lower per patient in the simultaneous group. CONCLUSIONS Simultaneous bilateral cataract surgery for infants with congenital cataracts was associated with a 21.9% reduction in medical payments and no discernible difference in the incidence of adverse events or visual outcome. PMID:20697007
An unsupervised classification technique for multispectral remote sensing data.
NASA Technical Reports Server (NTRS)
Su, M. Y.; Cummings, R. E.
1973-01-01
Description of a two-part clustering technique consisting of (a) a sequential statistical clustering, which is essentially a sequential variance analysis, and (b) a generalized K-means clustering. In this composite clustering technique, the output of (a) is a set of initial clusters which are input to (b) for further improvement by an iterative scheme. This unsupervised composite technique was employed for automatic classification of two sets of remote multispectral earth resource observations. The classification accuracy by the unsupervised technique is found to be comparable to that by traditional supervised maximum-likelihood classification techniques.
Unsupervised classification of earth resources data.
NASA Technical Reports Server (NTRS)
Su, M. Y.; Jayroe, R. R., Jr.; Cummings, R. E.
1972-01-01
A new clustering technique is presented. It consists of two parts: (a) a sequential statistical clustering which is essentially a sequential variance analysis and (b) a generalized K-means clustering. In this composite clustering technique, the output of (a) is a set of initial clusters which are input to (b) for further improvement by an iterative scheme. This unsupervised composite technique was employed for automatic classification of two sets of remote multispectral earth resource observations. The classification accuracy by the unsupervised technique is found to be comparable to that by existing supervised maximum liklihood classification technique.
Plane-Based Sampling for Ray Casting Algorithm in Sequential Medical Images
Lin, Lili; Chen, Shengyong; Shao, Yan; Gu, Zichun
2013-01-01
This paper proposes a plane-based sampling method to improve the traditional Ray Casting Algorithm (RCA) for the fast reconstruction of a three-dimensional biomedical model from sequential images. In the novel method, the optical properties of all sampling points depend on the intersection points when a ray travels through an equidistant parallel plan cluster of the volume dataset. The results show that the method improves the rendering speed at over three times compared with the conventional algorithm and the image quality is well guaranteed. PMID:23424608
Dose finding with the sequential parallel comparison design.
Wang, Jessie J; Ivanova, Anastasia
2014-01-01
The sequential parallel comparison design (SPCD) is a two-stage design recommended for trials with possibly high placebo response. A drug-placebo comparison in the first stage is followed in the second stage by placebo nonresponders being re-randomized between drug and placebo. We describe how SPCD can be used in trials where multiple doses of a drug or multiple treatments are compared with placebo and present two adaptive approaches. We detail how to analyze data in such trials and give recommendations about the allocation proportion to placebo in the two stages of SPCD.
Borg, Tyler D; Mealey, Brian L
2015-03-01
Mineralized and demineralized freeze-dried bone allografts (FDBAs) are used in alveolar ridge (AR) preservation; however, each material has advantages and disadvantages. Combinations of allografts aimed at capitalizing on the advantages each offers are available. To date, there is no evidence to indicate if a combination allograft is superior in this application. The primary objective of this study is to histologically evaluate and compare healing of non-molar extraction sites grafted with either mineralized FDBA or a 70:30 mineralized:demineralized FDBA combination allograft in AR preservation. The secondary objective is to compare dimensional changes in ridge height and width after grafting with these two materials. Forty-two patients randomized into two equal groups received ridge preservation with either 100% mineralized FDBA (active control group) or the combination 70% mineralized: 30% demineralized allograft (test group). Sites were allowed to heal for 18 to 20 weeks, at which time core biopsies were obtained and dental implants were placed. AR dimensions were evaluated at the time of extraction and at implant placement, including change in ridge width and change in buccal and lingual ridge height. Histomorphometric analysis was performed to determine percentage of vital bone, residual graft, and connective tissue/other non-bone components. There was no significant difference between groups in AR dimensional changes. Combination allograft produced increased vital bone percentage (36.16%) compared to the FDBA group (24.69%; P = 0.0116). The combination allograft also had a significantly lower mean percentage of residual graft particles (18.24%) compared to FDBA (27.04%; P = 0.0350). This study provides the first histologic evidence showing greater new bone formation with a combination mineralized/demineralized allograft compared to 100% mineralized FDBA in AR preservation in humans. Combination allograft results in increased vital bone formation while providing similar dimensional stability of the AR compared to FDBA alone in AR preservation.
Christenson, Stuart D; Chareonthaitawee, Panithaya; Burnes, John E; Hill, Michael R S; Kemp, Brad J; Khandheria, Bijoy K; Hayes, David L; Gibbons, Raymond J
2008-02-01
Cardiac resynchronization therapy (CRT) can improve left ventricular (LV) hemodynamics and function. Recent data suggest the energy cost of such improvement is favorable. The effects of sequential CRT on myocardial oxidative metabolism (MVO(2)) and efficiency have not been previously assessed. Eight patients with NYHA class III heart failure were studied 196 +/- 180 days after CRT implant. Dynamic [(11)C]acetate positron emission tomography (PET) and echocardiography were performed after 1 hour of: 1) AAI pacing, 2) simultaneous CRT, and 3) sequential CRT. MVO(2) was calculated using the monoexponential clearance rate of [(11)C]acetate (k(mono)). Myocardial efficiency was expressed in terms of the work metabolic index (WMI). P values represent overall significance from repeated measures analysis. Global LV and right ventricular (RV) MVO(2) were not significantly different between pacing modes, but the septal/lateral MVO(2) ratio differed significantly with the change in pacing mode (AAI pacing = 0.696 +/- 0.094 min(-1), simultaneous CRT = 0.975 +/- 0.143 min(-1), and sequential CRT = 0.938 +/- 0.189 min(-1); overall P = 0.001). Stroke volume index (SVI) (AAI pacing = 26.7 +/- 10.4 mL/m(2), simultaneous CRT = 30.6 +/- 11.2 mL/m(2), sequential CRT = 33.5 +/- 12.2 mL/m(2); overall P < 0.001) and WMI (AAI pacing = 3.29 +/- 1.34 mmHg*mL/m(2)*10(6), simultaneous CRT = 4.29 +/- 1.72 mmHg*mL/m(2)*10(6), sequential CRT = 4.79 +/- 1.92 mmHg*mL/m(2)*10(6); overall P = 0.002) also differed between pacing modes. Compared with simultaneous CRT, additional changes in septal/lateral MVO(2), SVI, and WMI with sequential CRT were not statistically significant on post hoc analysis. In this small selected population, CRT increases LV SVI without increasing MVO(2), resulting in improved myocardial efficiency. Additional improvements in LV work, oxidative metabolism, and efficiency from simultaneous to sequential CRT were not significant.
Liou, Jyh-Ming; Chen, Chieh-Chang; Fang, Yu-Jen; Chen, Po-Yueh; Chang, Chi-Yang; Chou, Chu-Kuang; Chen, Mei-Jyh; Tseng, Cheng-Hao; Lee, Ji-Yuh; Yang, Tsung-Hua; Chiu, Min-Chin; Yu, Jian-Jyun; Kuo, Chia-Chi; Luo, Jiing-Chyuan; Hsu, Wen-Feng; Hu, Wen-Hao; Tsai, Min-Horn; Lin, Jaw-Town; Shun, Chia-Tung; Twu, Gary; Lee, Yi-Chia; Bair, Ming-Jong; Wu, Ming-Shiang
2018-05-29
Whether extending the treatment length and the use of high-dose esomeprazole may optimize the efficacy of Helicobacter pylori eradication remains unknown. To compare the efficacy and tolerability of optimized 14 day sequential therapy and 10 day bismuth quadruple therapy containing high-dose esomeprazole in first-line therapy. We recruited 620 adult patients (≥20 years of age) with H. pylori infection naive to treatment in this multicentre, open-label, randomized trial. Patients were randomly assigned to receive 14 day sequential therapy or 10 day bismuth quadruple therapy, both containing esomeprazole 40 mg twice daily. Those who failed after 14 day sequential therapy received rescue therapy with 10 day bismuth quadruple therapy and vice versa. Our primary outcome was the eradication rate in the first-line therapy. Antibiotic susceptibility was determined. ClinicalTrials.gov: NCT03156855. The eradication rates of 14 day sequential therapy and 10 day bismuth quadruple therapy were 91.3% (283 of 310, 95% CI 87.4%-94.1%) and 91.6% (284 of 310, 95% CI 87.8%-94.3%) in the ITT analysis, respectively (difference -0.3%, 95% CI -4.7% to 4.4%, P = 0.886). However, the frequencies of adverse effects were significantly higher in patients treated with 10 day bismuth quadruple therapy than those treated with 14 day sequential therapy (74.4% versus 36.7% P < 0.0001). The eradication rate of 14 day sequential therapy in strains with and without 23S ribosomal RNA mutation was 80% (24 of 30) and 99% (193 of 195), respectively (P < 0.0001). Optimized 14 day sequential therapy was non-inferior to, but better tolerated than 10 day bismuth quadruple therapy and both may be used in first-line treatment in populations with low to intermediate clarithromycin resistance.
NASA Astrophysics Data System (ADS)
Demand, D.; Blume, T.; Weiler, M.
2017-12-01
Preferential flow in macropores significantly affects the distributions of water and solutes in soil and many studies showed its relevance worldwide. Although some models include this process as a second pore domain, little is known about the spatial patterns and temporal dynamics. For example, while flow in the matrix is usually modeled and parameterized based on soil texture, an influence of texture on non-capillary flow for a given land-use class is poorly understood. To investigate the temporal and spatial dynamics on preferential flow we used a four-year soil moisture dataset from the mesoscale Attert catchment (288 km²) in Luxembourg. This dataset contains time series from 126 soil profiles in different textures and two land-use classes (forest, grassland). The soil moisture probes were installed in 10, 30 and 50 cm depth and measured in a 5-minute temporal resolution. Events were defined by a soil moisture increase higher than the instrument noise after a precipitation sum of more than 1 mm. Precipitation was measured next to the profiles so that each location could be associated to its unique precipitation characteristics. For every event and profile the soil moisture reaction was classified in sequential (ordered by depth) and non-sequential response. A non-sequential soil moisture reaction was used as an indicator of preferential flow. For sequential flow, the velocity was determined by the first reaction between two vertically adjacent sensors. The sensor reaction and wetting front velocity was analyzed in the context of precipitation characteristics and initial soil water content. Grassland sites showed a lower proportion of non-sequential flow than forest sites. For forest, non-sequential response is dependent on texture, rainfall intensity and initial water content. This is less distinct for the grassland sites. Furthermore, sequential reactions show higher flow velocities at sites, which also have high percentage of non-sequential response. In contrast, grassland sites show a more homogenous wetting front independent of soil texture. Compared against common modelling approaches of soil water flow, measured velocities show clear evidence of preferential flow, especially for forest soils. The analysis also shows that vegetation can alter the soil properties above the textural properties alone.
Comparison of methods of preserving tissues for pesticide analysis
Stickel, W.H.; Stickel, L.F.; Dyrland, R.A.; Hughes, D.L.
1984-01-01
Formalin preservation, freezing, spoiling followed by freezing, and phenoxyethanol were compared in terms of concentrations of DDT, DDD, DDE, endrin, and hepatachlor epoxide measured in brain, liver and carcass of birds fed dietary dosages of pesticides and in spiked egg homogenate. Phenoxyethanol proved to be an unsatisfactory preservative; the amount of 'extractable lipid' was excessive, and measurements of concentrations in replicates were erratic. Concentrations of residues in formalin-preserved and frozen samples did not differ significantly in any tissue. Percentage lipid in brains and eggs, however, were significantly lower in formalin-preserved samples. Samples of muscle and liver that had been spoiled before freezing yielded less DDD, and muscle samples yielded more DDT than formalin-preserved samples. The authors conclude that formalin preservation is a satisfactory method for preservation of field samples and that the warming and spoiling of samples that may occur unavoidably in the field will not result in misleading analytical results.
Stan T. Lebow; Patricia K. Lebow; Kolby C. Hirth
2017-01-01
Current standardized methods are not well-suited for estimating in-service preservative leaching from treated wood products. This study compared several alternative leaching methods to a commonly used standard method, and to leaching under natural exposure conditions. Small blocks or lumber specimens were pressure treated with a wood preservative containing borax and...
Supercooling as a Viable Non-Freezing Cell Preservation Method of Rat Hepatocytes
Usta, O. Berk; Kim, Yeonhee; Ozer, Sinan; Bruinsma, Bote G.; Lee, Jungwoo; Demir, Esin; Berendsen, Tim A.; Puts, Catheleyne F.; Izamis, Maria-Louisa; Uygun, Korkut; Uygun, Basak E.; Yarmush, Martin L.
2013-01-01
Supercooling preservation holds the potential to drastically extend the preservation time of organs, tissues and engineered tissue products, and fragile cell types that do not lend themselves well to cryopreservation or vitrification. Here, we investigate the effects of supercooling preservation (SCP at -4oC) on primary rat hepatocytes stored in cryovials and compare its success (high viability and good functional characteristics) to that of static cold storage (CS at +4oC) and cryopreservation. We consider two prominent preservation solutions a) Hypothermosol (HTS-FRS) and b) University of Wisconsin solution (UW) and a range of preservation temperatures (-4 to -10 oC). We find that there exists an optimum temperature (-4oC) for SCP of rat hepatocytes which yields the highest viability; at this temperature HTS-FRS significantly outperforms UW solution in terms of viability and functional characteristics (secretions and enzymatic activity in suspension and plate culture). With the HTS-FRS solution we show that the cells can be stored for up to a week with high viability (~56%); moreover we also show that the preservation can be performed in large batches (50 million cells) with equal or better viability and no loss of functionality as compared to smaller batches (1.5 million cells) performed in cryovials. PMID:23874947
Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.
Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko
2017-01-01
There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total suppression of tinnitus compared with their unilateral situation. While bilateral cochlear implantation can have a positive effect on preoperative tinnitus complaints, the induction of (temporary or permanent) tinnitus was also reported. Dutch Trial Register NTR1722.
Hoppe, Katharina; Küper, Kristina; Wascher, Edmund
2017-01-01
In the Simon task, participants respond faster when the task-irrelevant stimulus position and the response position are corresponding, for example on the same side, compared to when they have a non-corresponding relation. Interestingly, this Simon effect is reduced after non-corresponding trials. Such sequential effects can be explained in terms of a more focused processing of the relevant stimulus dimension due to increased cognitive control, which transfers from the previous non-corresponding trial (conflict adaptation effects). Alternatively, sequential modulations of the Simon effect can also be due to the degree of trial-to-trial repetitions and alternations of task features, which is confounded with the correspondence sequence (feature integration effects). In the present study, we used a spatially two-dimensional Simon task with vertical response keys to examine the contribution of adaptive cognitive control and feature integration processes to the sequential modulation of the Simon effect. The two-dimensional Simon task creates correspondences in the vertical as well as in the horizontal dimension. A trial-by-trial alternation of the spatial dimension, for example from a vertical to a horizontal stimulus presentation, generates a subset containing no complete repetitions of task features, but only complete alternations and partial repetitions, which are equally distributed over all correspondence sequences. In line with the assumed feature integration effects, we found sequential modulations of the Simon effect only when the spatial dimension repeated. At least for the horizontal dimension, this pattern was confirmed by the parietal P3b, an event-related potential that is assumed to reflect stimulus–response link processes. Contrary to conflict adaptation effects, cognitive control, measured by the fronto-central N2 component of the EEG, was not sequentially modulated. Overall, our data provide behavioral as well as electrophysiological evidence for feature integration effects contributing to sequential modulations of the Simon effect. PMID:28713305
Hoppe, Katharina; Küper, Kristina; Wascher, Edmund
2017-01-01
In the Simon task, participants respond faster when the task-irrelevant stimulus position and the response position are corresponding, for example on the same side, compared to when they have a non-corresponding relation. Interestingly, this Simon effect is reduced after non-corresponding trials. Such sequential effects can be explained in terms of a more focused processing of the relevant stimulus dimension due to increased cognitive control, which transfers from the previous non-corresponding trial (conflict adaptation effects). Alternatively, sequential modulations of the Simon effect can also be due to the degree of trial-to-trial repetitions and alternations of task features, which is confounded with the correspondence sequence (feature integration effects). In the present study, we used a spatially two-dimensional Simon task with vertical response keys to examine the contribution of adaptive cognitive control and feature integration processes to the sequential modulation of the Simon effect. The two-dimensional Simon task creates correspondences in the vertical as well as in the horizontal dimension. A trial-by-trial alternation of the spatial dimension, for example from a vertical to a horizontal stimulus presentation, generates a subset containing no complete repetitions of task features, but only complete alternations and partial repetitions, which are equally distributed over all correspondence sequences. In line with the assumed feature integration effects, we found sequential modulations of the Simon effect only when the spatial dimension repeated. At least for the horizontal dimension, this pattern was confirmed by the parietal P3b, an event-related potential that is assumed to reflect stimulus-response link processes. Contrary to conflict adaptation effects, cognitive control, measured by the fronto-central N2 component of the EEG, was not sequentially modulated. Overall, our data provide behavioral as well as electrophysiological evidence for feature integration effects contributing to sequential modulations of the Simon effect.
Zemberyová, Mária; Barteková, Jana; Hagarová, Ingrid
2006-12-15
A modified three-step sequential extraction procedure for the fractionation of heavy metals, proposed by the Commission of the European Communities Bureau of Reference (BCR) has been applied to the Slovak reference materials of soils (soil orthic luvisols, soil rendzina and soil eutric cambisol), which represent pedologically different types of soils in Slovakia. Analyses were carried out by flame or electrothermal atomic absorption spectrometry (FAAS or ETAAS). The fractions extracted were: exchangeable (extraction step 1), reducible-iron/manganese oxides (extraction step 2), oxidizable-organic matter and sulfides (extraction step 3). The sum of the element contents in the three fractions plus aqua-regia extractable content of the residue was compared to the aqua-regia extractable content of the elements in the origin soils. The accuracy obtained by comparing the determined contents of the elements with certified values, using BCR CRM 701, certified for the extractable contents (mass fractions) of Cd, Cr, Cu, Ni, Pb and Zn in sediment following a modified BCR-three step sequential extraction procedure, was found to be satisfactory.
Parallel heuristics for scalable community detection
Lu, Hao; Halappanavar, Mahantesh; Kalyanaraman, Ananth
2015-08-14
Community detection has become a fundamental operation in numerous graph-theoretic applications. Despite its potential for application, there is only limited support for community detection on large-scale parallel computers, largely owing to the irregular and inherently sequential nature of the underlying heuristics. In this paper, we present parallelization heuristics for fast community detection using the Louvain method as the serial template. The Louvain method is an iterative heuristic for modularity optimization. Originally developed in 2008, the method has become increasingly popular owing to its ability to detect high modularity community partitions in a fast and memory-efficient manner. However, the method ismore » also inherently sequential, thereby limiting its scalability. Here, we observe certain key properties of this method that present challenges for its parallelization, and consequently propose heuristics that are designed to break the sequential barrier. For evaluation purposes, we implemented our heuristics using OpenMP multithreading, and tested them over real world graphs derived from multiple application domains. Compared to the serial Louvain implementation, our parallel implementation is able to produce community outputs with a higher modularity for most of the inputs tested, in comparable number or fewer iterations, while providing real speedups of up to 16x using 32 threads.« less
A novel solution configuration on liquid-based endometrial cytology
Wang, Qi; Han, Lu; Tuo, Xiaoqian; Hou, Huilian; Liu, Yu; Shi, Zan; Wang, Qing; Li, Yan; Sun, Chao; Xue, Xue
2018-01-01
Objective Early detection and diagnosis of endometrial carcinoma and precancerous change would undoubtedly become the most alluring part for researchers. With the emergence of endometrial brush samplers, a new upsurge in endometrial cytology is in the making. But endometrial specimens obtained by the endometrial brush samplers require special preservation solution. The objective of this study is to develop a new kind of endometrial-cell preservation solution and to test the availability compared with a patented liquid-based cell preservation solution. Methods In this controlled study, we had 5 endometrial cases collected with Li Brush from the First Affiliated Hospital of Xi'an Jiaotong University (09/2016 to 12/2016). The samples of each case were collected 2 times separately and perserved in different perservation solutions. One was a kind of novel endometrial cell preservation solution and the other was a kind of patented liquid-based cell (LBC) preservation solution. The endometrial cells were smeared on slides by using the ZP-C automated slide preparation system and stained with Papanicolaou stain. A semi-quantitative scoring system was used to analyze the quality of slides. Statistical analysis was performed using the Wilcoxon signed rank test on the SPSS program (SPSS 18.0). In all LBC preparations, endometrial cells from the novel endometrial cells preservation solution had more cell quantity, less red blood cell fragments, and the background was cleaner compared with control group. Although the novel endometrial-cell preservation solution showed cellularity and absence of blood and debris expressed by no statistically significant differences (p = 0.063 and 0.102 respectively). The preservation period of the two kinds of liquids was equivalent. Conclusions The novel endometrial-cell preservation solution is superior to the liquid-base cell preservation solution for cervical cells, with clear background, diagnostic cells and low cost. PMID:29401497
Dong, Jia-Hong; Ye, Sheng; Duan, Wei-Dong; Ji, Wen-Bing; Liang, Yu-Rong
2015-10-01
Cholecystectomy is routinely performed at most transplant centers during living donor liver transplantation (LDLT). This study was performed to evaluate the feasibility of liver graft procurement with donor gallbladder preservation in LDLT. Eighty-nine LDLTs (from June 2006 to Dec 2012) were retrospectively analyzed at our hospital. The surgical approach for liver graft procurement with donor gallbladder preservation was assessed, and the anatomy of the cystic artery, the morphology and contractibility of the preserved gallbladder, postoperative symptoms, and vascular and biliary complications were compared among donors with or without gallbladder preservation. Twenty-eight donors (15 right and 13 left-liver grafts) successfully underwent liver graft procurement with gallbladder preservation. Among the 15 right lobectomy donors, for 12 cases (80.0 %) the cystic artery originated from right hepatic artery. From the left hepatic artery and proper hepatic artery accounted for 6.7 % (1/15), respectively. Postoperative symptoms among these 28 donors were slight, although donors with cholecystectomy often complained of fatty food aversion, dyspepsia, and diarrhea during an average follow-up of 58.6 (44-78) months. The morphology and contractibility of the preserved gallbladders were comparable with normal status; the rate of contraction was 53.8 and 76.7 %, respectively, 30 and 60 min after ingestion of a fatty meal. Biliary and vascular complications among donors and recipients, irrespective of gallbladder preservation, were not significantly different. These data suggest that for donors compliant with anatomical requirements, liver graft procurement with gallbladder preservation for the donor is feasible and safe. The preserved gallbladder was assessed as functioning well and postoperative symptoms as a result of cholecystectomy were significantly reduced during long-term follow-up.
Apostolopoulos, Peter; Darby, Ivan
2017-04-01
Ridge preservation is any procedure that takes place at the time of, or shortly after an extraction, to minimise resorption of the ridge and maximise bone formation within the socket. The aim of this project is to investigate the outcome of implant treatment following ridge preservation and compare it to an ungrafted implant control group. Following ethics approval, an electronic and manual search of patient records was conducted, and appropriate cases of implant placement following a ridge preservation procedure were identified. Forty-two patients with 51 implants at ridge-preserved sites were examined by one author (PA) with the following parameters assessed at each implant: pocket probing depth, bleeding on probing, presence/absence of plaque and radiographic bone loss. Clinical and radiographic findings were compared to an ungrafted implant control group and analysed by years in function. There was a 100% survival rate of implants in ridge-preserved sites. In the majority of cases, ridge preservation was performed in the anterior maxilla with a flap raised and the use of deproteinised bovine bone mineral and collagen membrane materials. The mean time in function was 31 (±24) months with a range of 2-102 months. Differences in the mean PPD, BOP, plaque index and radiographic bone loss were not statistically significant between implants at ridge-preserved or ungrafted sites. The overall success rate was around 58% for ungrafted implants and around 51% for implants in ridge-preserved sites. However, this difference was not statistically significant. In this retrospective study, implant placement at ridge-preserved sites was a predictable procedure that led to very high survival rates and similar success rates to implant placement at ungrafted sites. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Haron, Adib; Mahdzair, Fazren; Luqman, Anas; Osman, Nazmie; Junid, Syed Abdul Mutalib Al
2018-03-01
One of the most significant constraints of Von Neumann architecture is the limited bandwidth between memory and processor. The cost to move data back and forth between memory and processor is considerably higher than the computation in the processor itself. This architecture significantly impacts the Big Data and data-intensive application such as DNA analysis comparison which spend most of the processing time to move data. Recently, the in-memory processing concept was proposed, which is based on the capability to perform the logic operation on the physical memory structure using a crossbar topology and non-volatile resistive-switching memristor technology. This paper proposes a scheme to map digital equality comparator circuit on memristive memory crossbar array. The 2-bit, 4-bit, 8-bit, 16-bit, 32-bit, and 64-bit of equality comparator circuit are mapped on memristive memory crossbar array by using material implication logic in a sequential and parallel method. The simulation results show that, for the 64-bit word size, the parallel mapping exhibits 2.8× better performance in total execution time than sequential mapping but has a trade-off in terms of energy consumption and area utilization. Meanwhile, the total crossbar area can be reduced by 1.2× for sequential mapping and 1.5× for parallel mapping both by using the overlapping technique.
NASA Astrophysics Data System (ADS)
Reaungamornrat, S.; Wang, A. S.; Uneri, A.; Otake, Y.; Zhao, Z.; Khanna, A. J.; Siewerdsen, J. H.
2014-03-01
Purpose: Deformable registration of preoperative and intraoperative images facilitates accurate localization of target and critical anatomy in image-guided spine surgery. However, conventional deformable registration fails to preserve the morphology of rigid bone anatomy and can impart distortions that confound high-precision intervention. We propose a constrained registration method that preserves rigid morphology while allowing deformation of surrounding soft tissues. Method: The registration method aligns preoperative 3D CT to intraoperative cone-beam CT (CBCT) using free-form deformation (FFD) with penalties on rigid body motion imposed according to a simple intensity threshold. The penalties enforced 3 properties of a rigid transformation - namely, constraints on affinity (AC), orthogonality (OC), and properness (PC). The method also incorporated an injectivity constraint (IC) to preserve topology. Physical experiments (involving phantoms, an ovine spine, and a human cadaver) as well as digital simulations were performed to evaluate the sensitivity to registration parameters, preservation of rigid body morphology, and overall registration accuracy of constrained FFD in comparison to conventional unconstrained FFD (denoted uFFD) and Demons registration. Result: FFD with orthogonality and injectivity constraints (denoted FFD+OC+IC) demonstrated improved performance compared to uFFD and Demons. Affinity and properness constraints offered little or no additional improvement. The FFD+OC+IC method preserved rigid body morphology at near-ideal values of zero dilatation (D = 0.05, compared to 0.39 and 0.56 for uFFD and Demons, respectively) and shear (S = 0.08, compared to 0.36 and 0.44 for uFFD and Demons, respectively). Target registration error (TRE) was similarly improved for FFD+OC+IC (0.7 mm), compared to 1.4 and 1.8 mm for uFFD and Demons. Results were validated in human cadaver studies using CT and CBCT images, with FFD+OC+IC providing excellent preservation of rigid morphology and equivalent or improved TRE. Conclusions: A promising method for deformable registration in CBCT-guided spine surgery has been identified incorporating a constrained FFD to preserve bone morphology. The approach overcomes distortions intrinsic to unconstrained FFD and could better facilitate high-precision image-guided spine surgery.
Serra-Guillén, Carlos; Nagore, Eduardo; Hueso, Luis; Traves, Victor; Messeguer, Francesc; Sanmartín, Onofre; Llombart, Beatriz; Requena, Celia; Botella-Estrada, Rafael; Guillén, Carlos
2012-04-01
Photodynamic therapy (PDT) and imiquimod are the treatments of choice for actinic keratosis (AK). As they have different mechanisms of action, it seems reasonable to assume that applying both treatments sequentially would be efficacious. We sought to determine which of these therapeutic modalities provides a better clinical and histologic response in patients with AK and whether sequential use of both was more efficacious than each separately. Patients were randomly assigned to one treatment group: group 1, PDT only; group 2, imiquimod only; or group 3, sequential use of PDT and imiquimod. The primary outcome measure was complete clinical response. Partial clinical response was defined as a reduction of more than 75% in the initial number of lesions. A complete clinicopathologic response was defined as lack of evidence of AK in the biopsy specimen. In all, 105 patients completed the study (group 1, 40 patients; group 2, 33 patients; group 3, 32 patients). Sequential application of PDT and imiquimod was more efficacious in all the outcome measures. More patients were satisfied with PDT than with the other two modalities (P = .003). No significant differences were observed among the 3 modalities and tolerance to treatment. Only one cycle of imiquimod was administered. The follow-up period was brief. Sequential application of PDT and imiquimod provides a significantly better clinical and histologic response in the treatment of AK than PDT or imiquimod monotherapy. It also produces less intense local reactions and better tolerance and satisfaction than imiquimod monotherapy. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Ordás, I; Domènech, E; Mañosa, M; García-Sánchez, V; Iglesias-Flores, E; Peñalva, M; Cañas-Ventura, A; Merino, O; Fernández-Bañares, F; Gomollón, F; Vera, M; Gutiérrez, A; Garcia-Planella, E; Chaparro, M; Aguas, M; Gento, E; Muñoz, F; Aguirresarobe, M; Muñoz, C; Fernández, L; Calvet, X; Jiménez, C E; Montoro, M A; Mir, A; De Castro, M L; García-Sepulcre, M F; Bermejo, F; Panés, J; Esteve, M
2017-11-01
To determine the efficacy and safety of cyclosporine (CyA) in a large national registry-based population of patients with steroid-refractory (SR) acute severe ulcerative colitis (ASUC) and to establish predictors of efficacy and adverse events. Multicenter study of SR-ASUC treated with CyA, based on data from the ENEIDA registry. SR-ASUC patients treated with infliximab (IFX) or sequential rescue therapy (CyA-IFX or IFX-CyA) were used as comparators. Of 740 SR-ASUC patients, 377 received CyA, 131 IFX and 63 sequential rescue therapy. The cumulative colectomy rate was higher in the CyA (24.1%) and sequential therapy (32.7%) than in the IFX group (14.5%; P=0.01) at 3 months and 5 years. There were no differences in early and late colectomy between CyA and IFX in patients treated after 2005. 62% of patients receiving CyA remained colectomy-free in the long term (median 71 months). There were no differences in mortality between CyA (2.4%), IFX (1.5%) and sequential therapy (0%; P=0.771). The proportion of patients with serious adverse events (SAEs) was lower in CyA (15.4%) than in IFX treated patients (26.5%) or sequential therapy (33.4%; P<0.001). This difference in favor of CyA was maintained when only patients treated after 2005 were analyzed. Treatment with CyA showed a lower rate of SAE and a similar efficacy to that of IFX thereby supporting the use of either CyA or IFX in SR-ASUC. In addition, the risk-benefit of sequential CyA-IFX for CyA non-responders is acceptable.
Recchia, Gabriel; Sahlgren, Magnus; Kanerva, Pentti; Jones, Michael N.
2015-01-01
Circular convolution and random permutation have each been proposed as neurally plausible binding operators capable of encoding sequential information in semantic memory. We perform several controlled comparisons of circular convolution and random permutation as means of encoding paired associates as well as encoding sequential information. Random permutations outperformed convolution with respect to the number of paired associates that can be reliably stored in a single memory trace. Performance was equal on semantic tasks when using a small corpus, but random permutations were ultimately capable of achieving superior performance due to their higher scalability to large corpora. Finally, “noisy” permutations in which units are mapped to other units arbitrarily (no one-to-one mapping) perform nearly as well as true permutations. These findings increase the neurological plausibility of random permutations and highlight their utility in vector space models of semantics. PMID:25954306
Gureckis, Todd M.; Love, Bradley C.
2009-01-01
We evaluate two broad classes of cognitive mechanisms that might support the learning of sequential patterns. According to the first, learning is based on the gradual accumulation of direct associations between events based on simple conditioning principles. The other view describes learning as the process of inducing the transformational structure that defines the material. Each of these learning mechanisms predict differences in the rate of acquisition for differently organized sequences. Across a set of empirical studies, we compare the predictions of each class of model with the behavior of human subjects. We find that learning mechanisms based on transformations of an internal state, such as recurrent network architectures (e.g., Elman, 1990), have difficulty accounting for the pattern of human results relative to a simpler (but more limited) learning mechanism based on learning direct associations. Our results suggest new constraints on the cognitive mechanisms supporting sequential learning behavior. PMID:20396653
Effective Identification of Similar Patients Through Sequential Matching over ICD Code Embedding.
Nguyen, Dang; Luo, Wei; Venkatesh, Svetha; Phung, Dinh
2018-04-11
Evidence-based medicine often involves the identification of patients with similar conditions, which are often captured in ICD (International Classification of Diseases (World Health Organization 2013)) code sequences. With no satisfying prior solutions for matching ICD-10 code sequences, this paper presents a method which effectively captures the clinical similarity among routine patients who have multiple comorbidities and complex care needs. Our method leverages the recent progress in representation learning of individual ICD-10 codes, and it explicitly uses the sequential order of codes for matching. Empirical evaluation on a state-wide cancer data collection shows that our proposed method achieves significantly higher matching performance compared with state-of-the-art methods ignoring the sequential order. Our method better identifies similar patients in a number of clinical outcomes including readmission and mortality outlook. Although this paper focuses on ICD-10 diagnosis code sequences, our method can be adapted to work with other codified sequence data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Padbury, Richard P.; Jur, Jesse S., E-mail: jsjur@ncsu.edu
Previous research exploring inorganic materials nucleation behavior on polymers via atomic layer deposition indicates the formation of hybrid organic–inorganic materials that form within the subsurface of the polymer. This has inspired adaptations to the process, such as sequential vapor infiltration, which enhances the diffusion of organometallic precursors into the subsurface of the polymer to promote the formation of a hybrid organic–inorganic coating. This work highlights the fundamental difference in mass uptake behavior between atomic layer deposition and sequential vapor infiltration using in-situ methods. In particular, in-situ quartz crystal microgravimetry is used to compare the mass uptake behavior of trimethyl aluminummore » in poly(butylene terephthalate) and polyamide-6 polymer thin films. The importance of trimethyl aluminum diffusion into the polymer subsurface and the subsequent chemical reactions with polymer functional groups are discussed.« less
Enhancing sequential time perception and storytelling ability of deaf and hard of hearing children.
Ingber, Sara; Eden, Sigal
2011-01-01
A 3-month intervention was conducted to enhance the sequential time perception and storytelling ability of young children with hearing loss. The children were trained to arrange pictorial episodes of temporal scripts and tell the stories they created. Participants (N = 34, aged 4-7 years) were divided into 2 groups based on whether their spoken-language gap was more or less than 1 year compared to age norms. They completed A. Kaufman and N. Kaufman's (1983) picture series subtest and Guralnik's (1982) storytelling test at pretest and posttest. Measures demonstrated significant improvement in sequential time and storytelling achievement postintervention. Three of the examined demographic variables revealed correlations: Participants with genetic etiology showed greater improvement in time sequencing and storytelling than participants with unknown etiology; early onset of treatment correlated with better achievement in time sequencing; cochlear implant users showed greater storytelling improvement than hearing aid users.
Mirza, Bilal; Lin, Zhiping
2016-08-01
In this paper, a meta-cognitive online sequential extreme learning machine (MOS-ELM) is proposed for class imbalance and concept drift learning. In MOS-ELM, meta-cognition is used to self-regulate the learning by selecting suitable learning strategies for class imbalance and concept drift problems. MOS-ELM is the first sequential learning method to alleviate the imbalance problem for both binary class and multi-class data streams with concept drift. In MOS-ELM, a new adaptive window approach is proposed for concept drift learning. A single output update equation is also proposed which unifies various application specific OS-ELM methods. The performance of MOS-ELM is evaluated under different conditions and compared with methods each specific to some of the conditions. On most of the datasets in comparison, MOS-ELM outperforms the competing methods. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pérez Cid, B; Fernández Alborés, A; Fernández Gómez, E; Faliqé López, E
2001-08-01
The conventional three-stage BCR sequential extraction method was employed for the fractionation of heavy metals in sewage sludge samples from an urban wastewater treatment plant and from an olive oil factory. The results obtained for Cu, Cr, Ni, Pb and Zn in these samples were compared with those attained by a simplified extraction procedure based on microwave single extractions and using the same reagents as employed in each individual BCR fraction. The microwave operating conditions in the single extractions (heating time and power) were optimized for all the metals studied in order to achieve an extraction efficiency similar to that of the conventional BCR procedure. The measurement of metals in the extracts was carried out by flame atomic absorption spectrometry. The results obtained in the first and third fractions by the proposed procedure were, for all metals, in good agreement with those obtained using the BCR sequential method. Although in the reducible fraction the extraction efficiency of the accelerated procedure was inferior to that of the conventional method, the overall metals leached by both microwave single and sequential extractions were basically the same (recoveries between 90.09 and 103.7%), except for Zn in urban sewage sludges where an extraction efficiency of 87% was achieved. Chemometric analysis showed a good correlation between the results given by the two extraction methodologies compared. The application of the proposed approach to a certified reference material (CRM-601) also provided satisfactory results in the first and third fractions, as it was observed for the sludge samples analysed.
Wang, Nelson; Qian, Pierre; Kumar, Shejil; Yan, Tristan D; Phan, Kevin
2016-04-15
There have been a myriad of studies investigating the effectiveness of N-acetylcysteine (NAC) in the prevention of contrast induced nephropathy (CIN) in patients undergoing coronary angiography (CAG) with or without percutaneous coronary intervention (PCI). However the consensus is still out about the effectiveness of NAC pre-treatment due to vastly mixed results amongst the literature. The aim of this study was to conduct a meta-analysis and trial sequential analysis to determine the effects of pre-operative NAC in lowering the incidence of CIN in patients undergoing CAG and/or PCI. A systematic literature search was performed to include all randomized controlled trials (RCTs) comparing NAC versus control as pretreatment for CAG and/or PCI. A traditional meta-analysis and several subgroup analyses were conducted using traditional meta-analysis with relative risk (RR), trial sequential analysis, and meta-regression analysis. 43 RCTs met our inclusion criteria giving a total of 3277 patients in both control and treatment arms. There was a significant reduction in the risk of CIN in the NAC treated group compared to control (OR 0.666; 95% CI, 0.532-0.834; I2=40.11%; p=0.004). Trial sequential analysis, using a relative risk reduction threshold of 15%, indicates that the evidence is firm. The results of the present paper support the use of NAC in the prevention of CIN in patients undergoing CAG±PCI. Future studies should focus on the benefits of NAC amongst subgroups of high-risk patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Yano, Tetsuo; Yamada, Mei; Inoue, Daisuke
2017-07-01
Teriparatide (TPTD), a recombinant human parathyroid hormone N-terminal fragment (1-34), is a widely used bone anabolic drug for osteoporosis. Sequential treatment with antiresorptives such as bisphosphonates after TPTD discontinuation is generally recommended. However, relative effects of bisphosphonates have not been determined. In the present study, we directly compared effects of risedronate (RIS) and alendronate (ALN) on bone mineral density (BMD), bone turnover, structural property and strength in ovariectomized (OVX) rats, when administered after TPTD. Female Sprague Dawley rats were divided into one sham-operated and eight ovariectomized groups. TPTD, RIS, and ALN were given subcutaneously twice per week for 4 or 8 weeks after 4 week treatment with TPTD. TPTD significantly increased BMD (+9.6%) in OVX rats after 4 weeks of treatment. 8 weeks after TPTD withdrawal, vehicle-treated group showed a blunted BMD increase of +8.4% from the baseline. In contrast, 8 weeks of treatment with RIS and ALN significantly increased BMD to 17.4 and 21.8%, respectively. While ALN caused a consistently larger increase in BMD, sequential treatment with RIS resulted in lower Tb.Sp compared to ALN in the fourth lumbar vertebra as well as in greater stiffness in compression test. In conclusion, the present study demonstrated that sequential therapy with ALN and RIS after TPTD both improved bone mass and structure. Our results further suggest that RIS may have a greater effect on improving bone quality and stiffness than ALN despite less prominent effect on BMD. Further studies are necessary to determine clinical relevance of these findings to fracture rate.
Efficacy of sequential three-step empirical therapy for chronic cough.
Yu, Li; Xu, Xianghuai; Hang, Jingqing; Cheng, Kewen; Jin, Xiaoyan; Chen, Qiang; Lv, Hanjing; Qiu, Zhongmin
2017-06-01
Empirical three-step therapy has been proved in just one hospital. This study aimed to demonstrate applicability of the sequential empirical three-step therapy for chronic cough in different clinical settings. Sequential empirical three-step therapy was given to patients with chronic cough in one tertiary and three secondary care respiratory clinics. Recruiters were initially treated with methoxyphenamine compound as the first-step therapy, followed by corticosteroids as the second-step therapy and the combination of a proton-pump inhibitor and a prokinetic agent as the third-step therapy. The efficacy of the therapy was verified according to the changes in cough symptom score between pre- and post-treatment, and compared among the different clinics. In total 155 patients in one tertiary clinic and 193 patients in secondary care clinics were recruited. The total dropout ratio is significantly higher in the secondary care clinics than that in the tertiary clinic (9.3% versus 3.2%, p = 0.023). The therapeutic success rate for cough was 38.7% at first-step therapy, 32.3% at second-step therapy and 20.0% at third-step therapy in the tertiary clinic, and comparable to corresponding 49.7%, 31.1% and 4.1% in secondary care clinics. Furthermore, the overall cough resolution rate was not significantly different (91.0% versus 85.0%, p = 0.091). However, the efficacy of the third-step therapy is much higher (20.0% versus 4.1%, p = 0.001) in the tertiary clinic than in the secondary care clinics. Sequential empirical three-step therapy is universally efficacious and useful for management of chronic cough in different clinical settings.
Shi, Yanwei; Ling, Wencui; Qiang, Zhimin
2013-01-01
The effect of chlorine dioxide (ClO2) oxidation on the formation of disinfection by-products (DBPs) during sequential (ClO2 pre-oxidation for 30 min) and simultaneous disinfection processes with free chlorine (FC) or monochloramine (MCA) was investigated. The formation of DBPs from synthetic humic acid (HA) water and three natural surface waters containing low bromide levels (11-27 microg/L) was comparatively examined in the FC-based (single FC, sequential ClO2-FC, and simultaneous ClO2/FC) and MCA-based (single MCA, ClO2-MCA, and ClO2/MCA) disinfection processes. The results showed that much more DBPs were formed from the synthetic HA water than from the three natural surface waters with comparative levels of dissolved organic carbon. In the FC-based processes, ClO2 oxidation could reduce trihalomethanes (THMs) by 27-35% and haloacetic acids (HAAs) by 14-22% in the three natural surface waters, but increased THMs by 19% and HAAs by 31% in the synthetic HA water after an FC contact time of 48 h. In the MCA-based processes, similar trends were observed although DBPs were produced at a much lower level. There was an insignificant difference in DBPs formation between the sequential and simultaneous processes. The presence of a high level of bromide (320 microg/L) remarkably promoted the DBPs formation in the FC-based processes. Therefore, the simultaneous disinfection process of ClO2/MCA is recommended particularly for waters with a high bromide level.
Hoomans, Ties; Severens, Johan L; Evers, Silvia M A A; Ament, Andre J H A
2009-01-01
Decisions about clinical practice change, that is, which guidelines to adopt and how to implement them, can be made sequentially or simultaneously. Decision makers adopting a sequential approach first compare the costs and effects of alternative guidelines to select the best set of guideline recommendations for patient management and subsequently examine the implementation costs and effects to choose the best strategy to implement the selected guideline. In an integral approach, decision makers simultaneously decide about the guideline and the implementation strategy on the basis of the overall value for money in changing clinical practice. This article demonstrates that the decision to use a sequential v. an integral approach affects the need for detailed information and the complexity of the decision analytic process. More importantly, it may lead to different choices of guidelines and implementation strategies for clinical practice change. The differences in decision making and decision analysis between the alternative approaches are comprehensively illustrated using 2 hypothetical examples. We argue that, in most cases, an integral approach to deciding about change in clinical practice is preferred, as this provides more efficient use of scarce health-care resources.
Evaluation of an antibiotic intravenous to oral sequential therapy program.
Pablos, Ana I; Escobar, Ismael; Albiñana, Sandra; Serrano, Olga; Ferrari, José M; Herreros de Tejada, Alberto
2005-01-01
This study was designed to analyse the drug consumption difference and economic impact of an antibiotic sequential therapy focused on quinolones. We studied the consumption of quinolones (ofloxacin/levofloxacin and ciprofloxacin) 6 months before and after the implementation of a sequential therapy program in hospitalised patients. It was calculated for each antibiotic, in its oral and intravenous forms, in defined daily dose (DDD/100 stays per day) and economical terms (drug acquisition cost). At the beginning of the program ofloxacin was replaced by levofloxacin and, since their clinical uses are similar, the consumption of both drugs was compared during the period. In economic terms, the consumption of intravenous quinolones decreased 60% whereas the consumption of oral quinolones increased 66%. In DDD/100 stays per day, intravenous forms consumption decreased 53% and oral forms consumption increased 36%. Focusing on quinolones, the implementation of a sequential therapy program based on promoting an early switch from intravenous to oral regimen has proved its capacity to alter the utilisation profile of these antibiotics. The program has permitted the hospital a global saving of 41420 dollars for these drugs during the period of time considered. Copyright (c) 2004 John Wiley & Sons, Ltd.
Zonnevijlle, E D; Somia, N N; Abadia, G P; Stremel, R W; Maldonado, C J; Werker, P M; Kon, M; Barker, J H
2000-09-01
Dynamic graciloplasty is used as a treatment modality for total urinary incontinence caused by a paralyzed sphincter. A problem with this application is undesirable fatigue of the muscle caused by continuous electrical stimulation. Therefore, the neosphincter must be trained via a rigorous regimen to transform it from a fatigue-prone state to a fatigue-resistant state. To avoid or shorten this training period, the application of sequential segmental neuromuscular stimulation (SSNS) was examined. This form of stimulation proved previously to be highly effective in acutely reducing fatigue caused by electrical stimulation. The contractile function and perfusion of gracilis muscles employed as neosphincters were compared between conventional, single-channel, continuous stimulation, and multichannel sequential stimulation in 8 dogs. The sequentially stimulated neosphincter proved to have an endurance 2.9 times longer (as measured by halftime to fatigue) than continuous stimulation and a better blood perfusion during stimulation (both of which were significant changes, p < 0.05). Clinically, this will not antiquate training of the muscle, but SSNS could reduce the need for long and rigorous training protocols, making dynamic graciloplasty more attractive as a method of treating urinary or fecal incontinence.
CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.
Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter
2002-03-01
We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.
Zeng, Dong; Gong, Changfei; Bian, Zhaoying; Huang, Jing; Zhang, Xinyu; Zhang, Hua; Lu, Lijun; Niu, Shanzhou; Zhang, Zhang; Liang, Zhengrong; Feng, Qianjin; Chen, Wufan; Ma, Jianhua
2016-11-21
Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for quick diagnosis and risk stratification of coronary artery disease. However, one major drawback of dynamic MPCT imaging is the heavy radiation dose to patients due to its dynamic image acquisition protocol. In this work, to address this issue, we present a robust dynamic MPCT deconvolution algorithm via adaptive-weighted tensor total variation (AwTTV) regularization for accurate residue function estimation with low-mA s data acquisitions. For simplicity, the presented method is termed 'MPD-AwTTV'. More specifically, the gains of the AwTTV regularization over the original tensor total variation regularization are from the anisotropic edge property of the sequential MPCT images. To minimize the associative objective function we propose an efficient iterative optimization strategy with fast convergence rate in the framework of an iterative shrinkage/thresholding algorithm. We validate and evaluate the presented algorithm using both digital XCAT phantom and preclinical porcine data. The preliminary experimental results have demonstrated that the presented MPD-AwTTV deconvolution algorithm can achieve remarkable gains in noise-induced artifact suppression, edge detail preservation, and accurate flow-scaled residue function and MPHM estimation as compared with the other existing deconvolution algorithms in digital phantom studies, and similar gains can be obtained in the porcine data experiment.
NASA Astrophysics Data System (ADS)
Zeng, Dong; Gong, Changfei; Bian, Zhaoying; Huang, Jing; Zhang, Xinyu; Zhang, Hua; Lu, Lijun; Niu, Shanzhou; Zhang, Zhang; Liang, Zhengrong; Feng, Qianjin; Chen, Wufan; Ma, Jianhua
2016-11-01
Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for quick diagnosis and risk stratification of coronary artery disease. However, one major drawback of dynamic MPCT imaging is the heavy radiation dose to patients due to its dynamic image acquisition protocol. In this work, to address this issue, we present a robust dynamic MPCT deconvolution algorithm via adaptive-weighted tensor total variation (AwTTV) regularization for accurate residue function estimation with low-mA s data acquisitions. For simplicity, the presented method is termed ‘MPD-AwTTV’. More specifically, the gains of the AwTTV regularization over the original tensor total variation regularization are from the anisotropic edge property of the sequential MPCT images. To minimize the associative objective function we propose an efficient iterative optimization strategy with fast convergence rate in the framework of an iterative shrinkage/thresholding algorithm. We validate and evaluate the presented algorithm using both digital XCAT phantom and preclinical porcine data. The preliminary experimental results have demonstrated that the presented MPD-AwTTV deconvolution algorithm can achieve remarkable gains in noise-induced artifact suppression, edge detail preservation, and accurate flow-scaled residue function and MPHM estimation as compared with the other existing deconvolution algorithms in digital phantom studies, and similar gains can be obtained in the porcine data experiment.
Bocos, Elvira; Brillas, Enric; Sanromán, M Ángeles; Sirés, Ignasi
2016-07-19
Electrocoagulation (EC) has long been considered a phase separation process, well suited for industrial wastewater treatment since it causes a quick, drastic decay of organic matter content. This research demonstrates that EC also behaves, at least for some molecules like the industrial preservative bronopol, as an effective transformation technology able to yield several breakdown products. This finding has relevant environmental implications, pointing to EC as a greener process than described in literature. A thorough optimization of EC was performed with solutions of bronopol in a simulated water matrix, yielding the complete disappearance of the parent molecule within 20 min at 200 mA (∼20 mA/cm(2)), using Fe as the anode and cathode. A 25% of total organic carbon (TOC) abatement was attained as maximum, with bronopol being converted into bromonitromethane, bromochloromethane, formaldehyde and formic acid. N atoms were accumulated as NO3(-), whereas Br(-) was stable once released. This suggests that mediated oxidation by active chlorine, as well as by hydroxyl radicals resulting from its reaction with iron ions, is the main transformation mechanism. Aiming to enhance the mineralization, a sequential combination of EC with electro-Fenton (EF) as post-treatment process was proposed. EF with boron-doped diamond (BDD) anode ensured the gradual TOC removal under the action of (•)OH and BDD((•)OH), also transforming Br(-) into BrO3(-).
Kronberg, James W.
1992-01-01
A sequential power-up circuit for starting several electrical load elements in series to avoid excessive current surge, comprising a voltage ramp generator and a set of voltage comparators, each comparator having a different reference voltage and interfacing with a switch that is capable of turning on one of the load elements. As the voltage rises, it passes the reference voltages one at a time and causes the switch corresponding to that voltage to turn on its load element. The ramp is turned on and off by a single switch or by a logic-level electrical signal. The ramp rate for turning on the load element is relatively slow and the rate for turning the elements off is relatively fast. Optionally, the duration of each interval of time between the turning on of the load elements is programmable.
NASA Astrophysics Data System (ADS)
Harris, Peter T.
1988-06-01
Large-scale bedforms (2-10 m in vertical and 10 2-10 3 m in horizontal dimensions) found in wide-mouthed estuaries are described. Different bedform types occur depending upon the local availability of sand. With an increasing sand supply, sand ribbons grade into elongate trains of sand waves and then form sandwave fields. Inshore, headland-associated sand banks are formed which multiply into en-echelon sand banks. Based upon a review of data on directions of sand transport from the Bristol Channel and Thames Estuary, U.K., and from Moreton Bay, Australia, charts of ebb- and flood-dominant transport zones are constructed for lower estuarine environments which have undergone different degrees of infilling. Linear sand banks are seen to delimit partially the boundaries between opposing sand transport zones. Transport paths demonstrate how sediments derived from outside of the estuary are dispersed through ebb and flood transport zones, to supply other areas of net deposition. A comparison between different estuaries reveals that variations in the compexity of ebb- and flood-dominant transport zones and the morphologies of large-scale bedforms are coupled with apparent changes in the relative amounts of sand available to each system. A model for the sequential infilling of estuaries and the evolution of large-scale bedforms is presented and applied to the interpretation of present day examples. Vertical sequences predicted to be generated by such bedform evolution are described and discussed, in terms of their preservation in the geological record.
Ortega-Rivas, Enrique; Salmerón-Ochoa, Iván
2014-01-01
Food drinks are normally processed to increase their shelf-life and facilitate distribution before consumption. Thermal pasteurization is quite efficient in preventing microbial spoilage of many types of beverages, but the applied heat may also cause undesirable biochemical and nutritious changes that may affect sensory attributes of the final product. Alternative methods of pasteurization that do not include direct heat have been investigated in order to obtain products safe for consumption, but with sensory attributes maintained as unchanged as possible. Food scientists interested in nonthermal food preservation technologies have claimed that such methods of preserving foods are equally efficient in microbial inactivation as compared with conventional thermal means of food processing. Researchers in the nonthermal food preservation area also affirm that alternative preservation technologies will not affect, as much as thermal processes, nutritional and sensory attributes of processed foods. This article reviews research in nonthermal food preservation, focusing on effects of processing of food drinks such as fruit juices and dairy products. Analytical techniques used to identify volatile flavor-aroma compounds will be reviewed and comparative effects for both thermal and nonthermal preservation technologies will be discussed.
2014-01-01
Background This article proposes an approach to comparing and assessing the adaptive capacity of multilateral health agencies in meeting country and individual healthcare needs. Most studies comparing multilateral health agencies have failed to clearly propose a method for conducting agency comparisons. Methods This study conducted a qualitative case study methodological approach, such that secondary and primary case study literature was used to conduct case study comparisons of multilateral health agencies. Results Through the proposed Sequential Comparative Analysis (SCA), the author found a more effective way to justify the selection of cases, compare and assess organizational transformative capacity, and to learn from agency success in policy sustainability processes. Conclusions To more affectively understand and explain why some multilateral health agencies are more capable of adapting to country and individual healthcare needs, SCA provides a methodological approach that may help to better understand why these agencies are so different and what we can learn from successful reform processes. As funding challenges continue to hamper these agencies' adaptive capacity, learning from each other will become increasingly important. PMID:24886283
Gómez, Eduardo J
2014-05-20
This article proposes an approach to comparing and assessing the adaptive capacity of multilateral health agencies in meeting country and individual healthcare needs. Most studies comparing multilateral health agencies have failed to clearly propose a method for conducting agency comparisons. This study conducted a qualitative case study methodological approach, such that secondary and primary case study literature was used to conduct case study comparisons of multilateral health agencies. Through the proposed Sequential Comparative Analysis (SCA), the author found a more effective way to justify the selection of cases, compare and assess organizational transformative capacity, and to learn from agency success in policy sustainability processes. To more affectively understand and explain why some multilateral health agencies are more capable of adapting to country and individual healthcare needs, SCA provides a methodological approach that may help to better understand why these agencies are so different and what we can learn from successful reform processes. As funding challenges continue to hamper these agencies' adaptive capacity, learning from each other will become increasingly important.
Rossi, G P; Seccia, T M; Miotto, D; Zucchetta, P; Cecchin, D; Calò, L; Puato, M; Motta, R; Caielli, P; Vincenzi, M; Ramondo, G; Taddei, S; Ferri, C; Letizia, C; Borghi, C; Morganti, A; Pessina, A C
2012-08-01
It is unclear whether revascularization of renal artery stenosis (RAS) by means of percutaneous renal angioplasty and stenting (PTRAS) is advantageous over optimal medical therapy. Hence, we designed a randomized clinical trial based on an optimized patient selection strategy and hard experimental endpoints. Primary objective of this study is to determine whether PTRAS is superior or equivalent to optimal medical treatment for preserving glomerular filtration rate (GFR) in the ischemic kidney as assessed by 99mTcDTPA sequential renal scintiscan. Secondary objectives of this study are to establish whether the two treatments are equivalent in lowering blood pressure, preserving overall renal function and regressing target organ damage, preventing cardiovascular events and improving quality of life. The study is designed as a prospective multicentre randomized, un-blinded two-arm study. Eligible patients will have clinical and angio-CT evidence of RAS. Inclusion criteria is RAS affecting the main renal artery or its major branches either >70% or, if <70, with post-stenotic dilatation. Renal function will be assessed with 99mTc-DTPA renal scintigraphy. Patients will be randomized to either arms considering both resistance index value in the ischemic kidney and the presence of unilateral/bilateral stenosis. Primary experimental endpoint will be the GFR of the ischemic kidney, assessed as quantitative variable by 99TcDTPA, and the loss of ischemic kidney defined as a categorical variable.
Hatcher, Jeffrey; Gu, He; Cheng, Zixi (Jack)
2016-01-01
Overproduction of reactive oxygen species (ROS), such as the superoxide radical (O2 ∙−), is associated with diseases which compromise cardiac autonomic function. Overexpression of SOD1 may offer protection against ROS damage to the cardiac autonomic nervous system, but reductions of O2 ∙− may interfere with normal cellular functions. We have selected the C57B6SJL-Tg (SOD1)2 Gur/J mouse as a model to determine whether SOD1 overexpression alters cardiac autonomic function, as measured by baroreflex sensitivity (BRS) and aortic depressor nerve (ADN) recordings, as well as evaluation of baseline heart rate (HR) and mean arterial pressure (MAP). Under isoflurane anesthesia, C57 wild-type and SOD1 mice were catheterized with an arterial pressure transducer and measurements of HR and MAP were taken. After establishing a baseline, hypotension and hypertension were induced by injection of sodium nitroprusside (SNP) and phenylephrine (PE), respectively, and ΔHR versus ΔMAP were recorded as a measure of baroreflex sensitivity (BRS). SNP and PE treatment were administered sequentially after a recovery period to measure arterial baroreceptor activation by recording aortic depressor nerve activity. Our findings show that overexpression of SOD1 in C57B6SJL-Tg (SOD1)2 Gur/J mouse preserved the normal HR, MAP, and BRS but enhanced aortic depressor nerve function. PMID:26823951
Bessems, M; Doorschodt, B M; van Vliet, A K; van Gulik, T M
2005-01-01
The increasing shortage of donor organs has led to a focus on extended criteria donors, including the non-heart-beating donor (NHBD). An optimal preservation method is required to facilitate successful transplantation of these ischemically damaged organs. The recent literature has shown clear advantages of hypothermic machine perfusion (MP) over cold storage (CS). For MP, modified University of Wisconsin perfusion solution (UW-G) is often used, which, however, is known to cause microcirculatory obstruction, is difficult to obtain, and is expensive. Therefore, Polysol was developed as a MP preservation solution that contains specific nutrients for the liver, such as amino acids, energy substrates, and vitamins. The aim of this study was to compare Polysol with UW-G in a NHBD rat liver model. After 24 hours hypothermic MP of NHBD rat livers using UW-G or Polysol, liver damage and function parameters were assessed during 60 minutes of reperfusion with Krebs-Henseleit buffer. Control livers were reperfused after 24 hours CS in UW. Liver enzyme release was significantly higher among the CS-UW group compared to MP using UW-G or Polysol. Flow during reperfusion was significantly higher when using Polysol compared to UW-G. Bile production and ammonia clearance were highest when using Polysol compared to UW-G. There was less cellular edema after preservation with Polysol compared to UW-G. MP of NHBD rat livers for 24 hours using UW-G or Polysol resulted in less hepatocellular damage than CS in UW. MP of NHBD livers for 24 hours using Polysol is superior to MP using UW-G.
Parekh, Mohit; Salvalaio, Gianni; Ferrari, Stefano; Amoureux, Marie-Claude; Albrecht, Cecile; Fortier, Denis; Ponzin, Diego
2014-12-01
To standardize a new evaluation technique for calculating the overall quality (OQ) of the donor cornea and validate it using a comparative study of corneas preserved in Optisol-GS and Cornea Cold®. Thirty pairs of donor corneas were selected for a 4 week in vitro comparative study using masked observers. Physiological parameters like thickness, transparency, viable endothelial cell density (VECD) and morphology were transformed to numerical range (0-4) to obtain the OQ. Microbiological examination was performed using Bactec instrument. Students t test showed statistically better results (p < 0.05) from week 3 for thickness, week 2 for transparency and week 1 for morphology and VECD; statistical significance (p < 0.05) was found for OQ from week 2 for the corneas preserved in Cornea Cold® compared to Optisol-GS. Epithelial quality was similar regardless of the medium. Microbiological examination showed absence of aerobic and anaerobic microorganisms in both media. OQ method is efficient, consistent and easy, now validated for comparative studies. Further refinement is necessary for its use at eye-banks, bio-banks and research or transplantation purposes. Cornea Cold® is a promising hypothermic corneal storage medium with preservation time ≤21 days. This permits higher flexibility, evaluation accuracy, longer duration for surgical preparation and ease of transportation.
Garau, J; Fritsch, A; Arvis, P; Read, R C
2010-08-01
The aim of this study was to compare outcomes for patients with community-acquired pneumonia (CAP) caused by Legionella spp. following treatment with moxifloxacin or a range of comparator antimicrobial agents. Data were pooled from four sequential I.V./P.O. trials of moxifloxacin in the treatment of CAP. Comparators were ceftriaxone +/- erythromycin, amoxicillin/clavulanate +/- clarithromycin, trovafloxacin, levofloxacin, or ceftriaxone + levofloxacin. Legionella infection was diagnosed by culture, urine antigen testing and/or serology. Clinical success rates for the efficacy-valid (per protocol) populations were recorded at the test-of-cure visit (5-30 days post-therapy). Severity of CAP was determined using the modified American Thoracic Society criteria.Of 1786 efficacy-valid patients, 33 (1.8%) had documented infection with Legionella spp. (moxifloxacin: n=13; comparator: n=20). Of these, 30 cases were identified by serology and/or urine antigen detection and 3 by respiratory culture. The success rate of moxifloxacin vs. comparator therapy was 92.3% vs. 80.0% for the I.V./P.O. trials.Sequential (I.V./P.O.) moxifloxacin demonstrated clinical efficacy that was at least as good as that of comparator treatments for the treatment of CAP due to Legionella.
Non-unique key B-Tree implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ries, D.R.
1980-12-23
The B-Trees are an indexed method to allow fast retrieval and order preserving updates to a FRAMIS relation based on a designated set of keys in the relation. A B-Tree access method is being implemented to provide indexed and sequential (in index order) access to FRAMIS relations. The implementation modifies the basic B-Tree structure to correctly allow multiple key values and still maintain the balanced page fill property of B-Trees. The data structures of the B-Tree are presented first, including the FRAMIS solution to the duplicate key value problem. Then the access level routines and utilities are presented. These routinesmore » include the original B-Tree creation; searching the B-Tree; and inserting, deleting, and replacing tuples on the B-Tree. In conclusion, the uses of the B-Tree access structures at the semantic level to enhance the FRAMIS performance are discussed. 10 figures.« less
Interpretive model for ''A Concurrency Method''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carter, C.L.
1987-01-01
This paper describes an interpreter for ''A Concurrency Method,'' in which concurrency is the inherent mode of operation and not an appendage to sequentiality. This method is based on the notions of data-drive and single-assignment while preserving a natural manner of programming. The interpreter is designed for and implemented on a network of Corvus Concept Personal Workstations, which are based on the Motorola MC68000 super-microcomputer. The interpreter utilizes the MC68000 processors in each workstation by communicating across OMNINET, the local area network designed for the workstations. The interpreter is a complete system, containing an editor, a compiler, an operating systemmore » with load balancer, and a communication facility. The system includes the basic arithmetic and trigonometric primitive operations for mathematical computations as well as the ability to construct more complex operations from these. 9 refs., 5 figs.« less
Crustal architecture and tectonic evolution of the Cauvery Suture Zone, southern India
NASA Astrophysics Data System (ADS)
Chetty, T. R. K.; Yellappa, T.; Santosh, M.
2016-11-01
The Cauvery suture zone (CSZ) in southern India has witnessed multiple deformations associated with multiple subduction-collision history, with incorporation of the related accretionary belts sequentially into the southern continental margin of the Archaean Dharwar craton since Neoarchean to Neoproterozoic. The accreted tectonic elements include suprasubduction complexes of arc magmatic sequences, high-grade supracrustals, thrust duplexes, ophiolites, and younger intrusions that are dispersed along the suture. The intra-oceanic Neoarchean-Neoproterozoic arc assemblages are well exposed in the form of tectonic mélanges dominantly towards the eastern sector of the CSZ and are typically subjected to complex and multiple deformation events. Multi-scale analysis of structural elements with detailed geological mapping of the sub-regions and their structural cross sections, geochemical and geochronological data and integrated geophysical observations suggest that the CSZ is an important zone that preserves the imprints of multiple cycles of Precambrian plate tectonic regimes.
Minamiguchi, Hitoshi; Oginosawa, Yasushi; Kohno, Ritsuko; Tamura, Masahito; Takeuchi, Masaaki; Otsuji, Yutaka; Abe, Haruhiko
2012-07-01
A 91-year-old woman received a dual-chamber pacemaker for sick sinus syndrome and intermittently abnormal atrioventricular (AV) conduction. The pacemaker was set in DDI mode with a 350-ms AV delay to preserve intrinsic ventricular activity. She complained of palpitation during AV sequential pacing. The electrocardiogram showed a 2:1 AV rhythm from 1:1 ventriculoatrial (VA) conduction during ventricular pacing in DDI mode with a long AV interval. After reprogramming of the pacemaker in DDD mode with a 250-ms AV interval and additional 100-ms prolongation of the AV interval by the ventricular intrinsic preference function, VA conduction disappeared and the patient's symptom were alleviated without increasing unnecessary right ventricular pacing. ©2011, The Authors. Journal compilation ©2011 Wiley Periodicals, Inc.
Temporal Interactions between Cortical Rhythms
Roopun, Anita K.; Kramer, Mark A.; Carracedo, Lucy M.; Kaiser, Marcus; Davies, Ceri H.; Traub, Roger D.; Kopell, Nancy J.; Whittington, Miles A.
2008-01-01
Multiple local neuronal circuits support different, discrete frequencies of network rhythm in neocortex. Relationships between different frequencies correspond to mechanisms designed to minimise interference, couple activity via stable phase interactions, and control the amplitude of one frequency relative to the phase of another. These mechanisms are proposed to form a framework for spectral information processing. Individual local circuits can also transform their frequency through changes in intrinsic neuronal properties and interactions with other oscillating microcircuits. Here we discuss a frequency transformation in which activity in two co-active local circuits may combine sequentially to generate a third frequency whose period is the concatenation sum of the original two. With such an interaction, the intrinsic periodicity in each component local circuit is preserved – alternate, single periods of each original rhythm form one period of a new frequency – suggesting a robust mechanism for combining information processed on multiple concurrent spatiotemporal scales. PMID:19225587
Hiyoshi, Masahide; Chijiiwa, Kazuo; Ohuchida, Jiro; Imamura, Naoya; Nagano, Motoaki
2012-06-01
Delayed gastric emptying (DGE) is a specific, worrisome complication after pancreaticoduodenectomy (PPPD), whereas subtotal stomach-preserving pancreaticoduodenectomy (SSPPD) that excises the pylorus ring seems to be effective in reducing DGE. This study compared gastric emptying and nutritional status between PPPD and SSPPD over 1 year. From June 2003 to December 2007, 41 patients (PPPD: 33, SSPPD: 8) were enrolled in this study to evaluate differences in gastric emptying and nutritional status at 1, 3, 6, 9 and 12 months after pancreaticoduodenectomy. Gastric emptying was evaluated by 13C-acetate breath test. Nutritional status (body weight, serum levels of total protein, albumin and total cholesterol) was similarly assessed. At 1 month, gastric emptying evaluated at T1/2 (half-emptying time) was significantly prolonged in the PPPD but not in the SSPPD compared to the preoperative level. Thereafter, T1/2 was decreased and showed function significantly better preserved at 3, 6 and 12 months after PPPD than after SSPPD. Body weight recovery was significantly better at 6 and 12 months after PPPD than after SSPPD. Other nutritional parameters were better preserved in the PPPD during 1-year follow-up. PPPD seems to be a more suitable surgical procedure than SSPPD in regard to gastric emptying and nutritional status.
Is it me? Verbal self-monitoring neural network and clinical insight in schizophrenia
Sapara, Adegboyega; ffytche, Dominic H.; Cooke, Michael A.; Williams, Steven C.R.; Kumari, Veena
2015-01-01
Self-monitoring, defined as the ability to distinguish between self-generated stimuli from other-generated ones, is known to be impaired in schizophrenia. This impairment has been theorised as the basis for many of the core psychotic symptoms, in particular, poor clinical insight. This study aimed to investigate verbal self-monitoring related neural substrates of preserved and poor clinical insight in schizophrenia. It involved 40 stable schizophrenia outpatients, 20 with preserved and 20 with poor insight, and 20 healthy participants. All participants underwent functional magnetic resonance imaging with brain coverage covering key areas in the self-monitoring network during a verbal self-monitoring task. Healthy participants showed higher performance accuracy and greater thalamic activity than both preserved and poor insight patient groups. Preserved insight patients showed higher activity in the putamen extending into the caudate, insula and inferior frontal gyrus, compared to poor insight patients, and in the anterior cingulate and medial frontal gyrus, compared to healthy participants. Poor insight patients did not show greater activity in any brain area compared to preserved insight patients or healthy participants. Future studies may pursue therapeutic avenues, such as meta-cognitive therapies to promote self-monitoring or targeted stimulation of relevant brain areas, as means of enhancing insight in schizophrenia. PMID:26549744
McNelis, K A
1998-12-01
This study compared the efficacy of a common medication diluent, bacteriostatic 0.9% sodium chloride containing the preservative benzyl alcohol with lidocaine hydrochloride 1% as an intradermal pretreatment for the relief of pain associated with intravenous cannulation. Forty adult presurgical patients requiring two large bore intravenous catheters were used. They served as their own controls. The inner aspect of one forearm received the usual pretreatment, lidocaine hydrochloride 1%, and the inner aspect of the opposite arm received intradermal pretreatment with bacteriostatic 0.9% sodium chloride with the preservative benzyl alcohol. Intravenous cannulation was accomplished on the first attempt, and pain reported with cannulation was rated using a visual analogue scale (VAS). A paired t test was used to compare differences in VAS scores with the pretreatment bacteriostatic 0.9% sodium chloride containing the preservative benzyl alcohol with the pretreatment lidocaine hydrochloride 1%. Analysis of the data revealed no significant difference in the report of perceived pain of intravenous cannulation based on the intradermal pretreatment. These findings suggest that intradermal bacteriostatic 0.9% sodium chloride containing the preservative benzyl alcohol is as effective as intradermal lidocaine hydrochloride 1% in the attenuation of intravenous cannulation pain.
Sfontouris, Ioannis A; Martins, Wellington P; Nastri, Carolina O; Viana, Iara G R; Navarro, Paula A; Raine-Fenning, Nick; van der Poel, Sheryl; Rienzi, Laura; Racowsky, Catherine
2016-10-01
The purpose of this study was to undertake a review of the available evidence comparing the use of a single medium versus sequential media for embryo culture to the blastocyst stage in clinical IVF. We searched the Cochrane Central, PubMed, Scopus, ClinicalTrials.gov, Current Controlled Trials and WHO International Clinical Trials Registry Platform to identify randomized controlled trials comparing single versus sequential media for blastocyst culture and ongoing pregnancy rate. Included studies randomized either oocytes/zygotes or women. Eligible oocyte/zygote studies were analyzed to assess the risk difference (RD) and 95 % confidence intervals (CI) between the two media systems; eligible woman-based studies were analyzed to assess the risk ratio (RR) and 95 % CI for clinical pregnancy rate. No differences were observed between single and sequential media for either ongoing pregnancy per randomized woman (relative risk (RR) = 0.9, 95 % CI = 0.7 to 1.3, two studies including 246 women, I 2 = 0 %) or clinical pregnancy per randomized woman (RR = 1.0, 95 % CI = 0.7 to 1.4, one study including 100 women); or miscarriage per clinical pregnancy: RR = 1.3, 95 % CI = 0.4 to 4.3, two studies including 246 participants, I 2 = 0 %). Single media use was associated with an increase blastocyst formation per randomized oocyte/zygote (relative distribution (RD) = +0.06, 95 % CI = +0.01 to +0.12, ten studies including 7455 oocytes/zygotes, I 2 = 83 %) but not top/high blastocyst formation (RD = +0.05, 95 % CI = -0.01 to +0.11, five studies including 3879 oocytes/zygotes, I 2 = 93 %). The overall quality of the evidence was very low for all these four outcomes. Although using a single medium for extended culture has some practical advantages and blastocyst formation rates appear to be higher, there is insufficient evidence to recommend either sequential or single-step media as being superior for the culture of embryos to days 5/6. Future studies comparing these two media systems in well-designed trials should be performed.
Reducing interaction in simultaneous paired stimulation with CI.
Vellinga, Dirk; Bruijn, Saskia; Briaire, Jeroen J; Kalkman, Randy K; Frijns, Johan H M
2017-01-01
In this study simultaneous paired stimulation of electrodes in cochlear implants is investigated by psychophysical experiments in 8 post-lingually deaf subjects (and one extra subject who only participated in part of the experiments). Simultaneous and sequential monopolar stimulation modes are used as references and are compared to channel interaction compensation, partial tripolar stimulation and a novel sequential stimulation strategy named phased array compensation. Psychophysical experiments are performed to investigate both the loudness integration during paired stimulation at the main electrodes as well as the interaction with the electrode contact located halfway between the stimulating pair. The study shows that simultaneous monopolar stimulation has more loudness integration on the main electrodes and more interaction in between the electrodes than sequential stimulation. Channel interaction compensation works to reduce the loudness integration at the main electrodes, but does not reduce the interaction in between the electrodes caused by paired stimulation. Partial tripolar stimulation uses much more current to reach the needed loudness, but shows the same interaction in between the electrodes as sequential monopolar stimulation. In phased array compensation we have used the individual impedance matrix of each subject to calculate the current needed on each electrode to exactly match the stimulation voltage along the array to that of sequential stimulation. The results show that the interaction in between the electrodes is the same as monopolar stimulation. The strategy uses less current than partial tripolar stimulation, but more than monopolar stimulation. In conclusion, the paper shows that paired stimulation is possible if the interaction is compensated.
Efficient sequential and parallel algorithms for record linkage.
Mamun, Abdullah-Al; Mi, Tian; Aseltine, Robert; Rajasekaran, Sanguthevar
2014-01-01
Integrating data from multiple sources is a crucial and challenging problem. Even though there exist numerous algorithms for record linkage or deduplication, they suffer from either large time needs or restrictions on the number of datasets that they can integrate. In this paper we report efficient sequential and parallel algorithms for record linkage which handle any number of datasets and outperform previous algorithms. Our algorithms employ hierarchical clustering algorithms as the basis. A key idea that we use is radix sorting on certain attributes to eliminate identical records before any further processing. Another novel idea is to form a graph that links similar records and find the connected components. Our sequential and parallel algorithms have been tested on a real dataset of 1,083,878 records and synthetic datasets ranging in size from 50,000 to 9,000,000 records. Our sequential algorithm runs at least two times faster, for any dataset, than the previous best-known algorithm, the two-phase algorithm using faster computation of the edit distance (TPA (FCED)). The speedups obtained by our parallel algorithm are almost linear. For example, we get a speedup of 7.5 with 8 cores (residing in a single node), 14.1 with 16 cores (residing in two nodes), and 26.4 with 32 cores (residing in four nodes). We have compared the performance of our sequential algorithm with TPA (FCED) and found that our algorithm outperforms the previous one. The accuracy is the same as that of this previous best-known algorithm.
Niu, Shanzhou; Zhang, Shanli; Huang, Jing; Bian, Zhaoying; Chen, Wufan; Yu, Gaohang; Liang, Zhengrong; Ma, Jianhua
2016-01-01
Cerebral perfusion x-ray computed tomography (PCT) is an important functional imaging modality for evaluating cerebrovascular diseases and has been widely used in clinics over the past decades. However, due to the protocol of PCT imaging with repeated dynamic sequential scans, the associative radiation dose unavoidably increases as compared with that used in conventional CT examinations. Minimizing the radiation exposure in PCT examination is a major task in the CT field. In this paper, considering the rich similarity redundancy information among enhanced sequential PCT images, we propose a low-dose PCT image restoration model by incorporating the low-rank and sparse matrix characteristic of sequential PCT images. Specifically, the sequential PCT images were first stacked into a matrix (i.e., low-rank matrix), and then a non-convex spectral norm/regularization and a spatio-temporal total variation norm/regularization were then built on the low-rank matrix to describe the low rank and sparsity of the sequential PCT images, respectively. Subsequently, an improved split Bregman method was adopted to minimize the associative objective function with a reasonable convergence rate. Both qualitative and quantitative studies were conducted using a digital phantom and clinical cerebral PCT datasets to evaluate the present method. Experimental results show that the presented method can achieve images with several noticeable advantages over the existing methods in terms of noise reduction and universal quality index. More importantly, the present method can produce more accurate kinetic enhanced details and diagnostic hemodynamic parameter maps. PMID:27440948
Automatic sequential fluid handling with multilayer microfluidic sample isolated pumping
Liu, Jixiao; Fu, Hai; Yang, Tianhang; Li, Songjing
2015-01-01
To sequentially handle fluids is of great significance in quantitative biology, analytical chemistry, and bioassays. However, the technological options are limited when building such microfluidic sequential processing systems, and one of the encountered challenges is the need for reliable, efficient, and mass-production available microfluidic pumping methods. Herein, we present a bubble-free and pumping-control unified liquid handling method that is compatible with large-scale manufacture, termed multilayer microfluidic sample isolated pumping (mμSIP). The core part of the mμSIP is the selective permeable membrane that isolates the fluidic layer from the pneumatic layer. The air diffusion from the fluidic channel network into the degassing pneumatic channel network leads to fluidic channel pressure variation, which further results in consistent bubble-free liquid pumping into the channels and the dead-end chambers. We characterize the mμSIP by comparing the fluidic actuation processes with different parameters and a flow rate range of 0.013 μl/s to 0.097 μl/s is observed in the experiments. As the proof of concept, we demonstrate an automatic sequential fluid handling system aiming at digital assays and immunoassays, which further proves the unified pumping-control and suggests that the mμSIP is suitable for functional microfluidic assays with minimal operations. We believe that the mμSIP technology and demonstrated automatic sequential fluid handling system would enrich the microfluidic toolbox and benefit further inventions. PMID:26487904
Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard
2013-01-01
Background Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a ‘white-coat’ effect. Aim To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Design and setting Retrospective study in a teaching hospital in Birmingham. Method Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Result Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Conclusion Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the ‘white-coat’ effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm. PMID:23561681
Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard
2013-02-01
Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a 'white-coat' effect. To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Retrospective study in a teaching hospital in Birmingham. Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the 'white-coat' effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm.
Chen, Chee Kean; Lau, Francis C S; Lee, Woo Guan; Phui, Vui Eng
2016-09-01
To compare the anesthetic potency and safety of spinal anesthesia with higher dosages of levobupivacaine and bupivacaine in patients for bilateral sequential for total knee arthroplasty (TKA). Retrospective cohort study. Operation theater with postoperative inpatient follow-up. The medical records of 315 patients who underwent sequential bilateral TKA were reviewed. Patients who received intrathecal levobupicavaine 0.5% were compared with patients who received hyperbaric bupivacaine 0.5% with fentanyl 25 μg for spinal anesthesia. The primary outcome was the use of rescue analgesia (systemic opioids, conversion to general anesthesia) during surgery for both groups. Secondary outcomes included adverse effects of local anesthetics (hypotension and bradycardia) during surgery and morbidity related to spinal anesthesia (postoperative nausea, vomiting, and bleeding) during hospital stay. One hundred fifty patients who received intrathecal levobupivacaine 0.5% (group L) were compared with 90 patients given hyperbaric bupivacaine 0.5% with fentanyl 25 μg (group B). The mean volume of levobupivacaine administered was 5.8 mL (range, 5.0-6.0 mL), and that of bupivacaine was 3.8 mL (range, 3.5-4.0 mL). Both groups achieved similar maximal sensory level of block (T6). The time to maximal height of sensory block was significantly shorter in group B than group L, 18.2 ± 4.5 vs 23.9 ± 3.8 minutes (P< .001). The time to motor block of Bromage 3 was also shorter in group B (8.7 ± 4.1 minutes) than group L (16.0 ± 4.5 minutes) (P< .001). Patients in group B required more anesthetic supplement than group L (P< .001). Hypotension and postoperative bleeding were significantly less common in group L than group B. Levobupivacaine at a higher dosage provided longer duration of spinal anesthesia with better safety profile in sequential bilateral TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Boessen, Ruud; van der Baan, Frederieke; Groenwold, Rolf; Egberts, Antoine; Klungel, Olaf; Grobbee, Diederick; Knol, Mirjam; Roes, Kit
2013-01-01
Two-stage clinical trial designs may be efficient in pharmacogenetics research when there is some but inconclusive evidence of effect modification by a genomic marker. Two-stage designs allow to stop early for efficacy or futility and can offer the additional opportunity to enrich the study population to a specific patient subgroup after an interim analysis. This study compared sample size requirements for fixed parallel group, group sequential, and adaptive selection designs with equal overall power and control of the family-wise type I error rate. The designs were evaluated across scenarios that defined the effect sizes in the marker positive and marker negative subgroups and the prevalence of marker positive patients in the overall study population. Effect sizes were chosen to reflect realistic planning scenarios, where at least some effect is present in the marker negative subgroup. In addition, scenarios were considered in which the assumed 'true' subgroup effects (i.e., the postulated effects) differed from those hypothesized at the planning stage. As expected, both two-stage designs generally required fewer patients than a fixed parallel group design, and the advantage increased as the difference between subgroups increased. The adaptive selection design added little further reduction in sample size, as compared with the group sequential design, when the postulated effect sizes were equal to those hypothesized at the planning stage. However, when the postulated effects deviated strongly in favor of enrichment, the comparative advantage of the adaptive selection design increased, which precisely reflects the adaptive nature of the design. Copyright © 2013 John Wiley & Sons, Ltd.
Image segmentation on adaptive edge-preserving smoothing
NASA Astrophysics Data System (ADS)
He, Kun; Wang, Dan; Zheng, Xiuqing
2016-09-01
Nowadays, typical active contour models are widely applied in image segmentation. However, they perform badly on real images with inhomogeneous subregions. In order to overcome the drawback, this paper proposes an edge-preserving smoothing image segmentation algorithm. At first, this paper analyzes the edge-preserving smoothing conditions for image segmentation and constructs an edge-preserving smoothing model inspired by total variation. The proposed model has the ability to smooth inhomogeneous subregions and preserve edges. Then, a kind of clustering algorithm, which reasonably trades off edge-preserving and subregion-smoothing according to the local information, is employed to learn the edge-preserving parameter adaptively. At last, according to the confidence level of segmentation subregions, this paper constructs a smoothing convergence condition to avoid oversmoothing. Experiments indicate that the proposed algorithm has superior performance in precision, recall, and F-measure compared with other segmentation algorithms, and it is insensitive to noise and inhomogeneous-regions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mock, D.M.; DuBois, D.B.
1986-03-01
Interest in accurate measurement of biotin concentrations in plasma and urine has been stimulated by recent advances in the understanding of biotin-responsive inborn errors of metabolism and by several reports describing acquired biotin deficiency during parenteral alimentation. This paper presents a biotin assay utilizing radiolabeled avidin in a sequential, solid-phase method; the assay has increased sensitivity compared to previous methods (greater than or equal to 10 fmol/tube), correlates with expected trends in biotin concentrations in blood and urine in a rat model of biotin deficiency, and can utilize commercially available radiolabeled avidin.
Poster error probability in the Mu-11 Sequential Ranging System
NASA Technical Reports Server (NTRS)
Coyle, C. W.
1981-01-01
An expression is derived for the posterior error probability in the Mu-2 Sequential Ranging System. An algorithm is developed which closely bounds the exact answer and can be implemented in the machine software. A computer simulation is provided to illustrate the improved level of confidence in a ranging acquisition using this figure of merit as compared to that using only the prior probabilities. In a simulation of 20,000 acquisitions with an experimentally determined threshold setting, the algorithm detected 90% of the actual errors and made false indication of errors on 0.2% of the acquisitions.
Evaluation of Bayesian Sequential Proportion Estimation Using Analyst Labels
NASA Technical Reports Server (NTRS)
Lennington, R. K.; Abotteen, K. M. (Principal Investigator)
1980-01-01
The author has identified the following significant results. A total of ten Large Area Crop Inventory Experiment Phase 3 blind sites and analyst-interpreter labels were used in a study to compare proportional estimates obtained by the Bayes sequential procedure with estimates obtained from simple random sampling and from Procedure 1. The analyst error rate using the Bayes technique was shown to be no greater than that for the simple random sampling. Also, the segment proportion estimates produced using this technique had smaller bias and mean squared errors than the estimates produced using either simple random sampling or Procedure 1.
Revisiting Pneumatic Nail Gun Trigger Recommendations.
Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley
2015-03-01
Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.
Inverse problems in 1D hemodynamics on systemic networks: a sequential approach.
Lombardi, D
2014-02-01
In this work, a sequential approach based on the unscented Kalman filter is applied to solve inverse problems in 1D hemodynamics, on a systemic network. For instance, the arterial stiffness is estimated by exploiting cross-sectional area and mean speed observations in several locations of the arteries. The results are compared with those ones obtained by estimating the pulse wave velocity and the Moens-Korteweg formula. In the last section, a perspective concerning the identification of the terminal models parameters and peripheral circulation (modeled by a Windkessel circuit) is presented. Copyright © 2013 John Wiley & Sons, Ltd.
Shortreed, Susan M.; Moodie, Erica E. M.
2012-01-01
Summary Treatment of schizophrenia is notoriously difficult and typically requires personalized adaption of treatment due to lack of efficacy of treatment, poor adherence, or intolerable side effects. The Clinical Antipsychotic Trials in Intervention Effectiveness (CATIE) Schizophrenia Study is a sequential multiple assignment randomized trial comparing the typical antipsychotic medication, perphenazine, to several newer atypical antipsychotics. This paper describes the marginal structural modeling method for estimating optimal dynamic treatment regimes and applies the approach to the CATIE Schizophrenia Study. Missing data and valid estimation of confidence intervals are also addressed. PMID:23087488
2011-01-01
Background The use of energy crops and agricultural residues is expected to increase to fulfil the legislative demands of bio-based components in transport fuels. Ensiling methods, adapted from the feed sector, are suitable storage methods to preserve fresh crops throughout the year for, for example, biogas production. Various preservation methods, namely ensiling with and without acid addition for whole crop maize, fibre hemp and faba bean were investigated. For the drier fibre hemp, alkaline urea treatment was studied as well. These treatments were also explored as mild pretreatment methods to improve the disassembly and hydrolysis of these lignocellulosic substrates. Results The investigated storage treatments increased the availability of the substrates for biogas production from hemp and in most cases from whole maize but not from faba bean. Ensiling of hemp, without or with addition of formic acid, increased methane production by more than 50% compared to fresh hemp. Ensiling resulted in substantially increased methane yields also from maize, and the use of formic acid in ensiling of maize further enhanced methane yields by 16%, as compared with fresh maize. Ensiled faba bean, in contrast, yielded somewhat less methane than the fresh material. Acidic additives preserved and even increased the amount of the valuable water-soluble carbohydrates during storage, which affected most significantly the enzymatic hydrolysis yield of maize. However, preservation without additives decreased the enzymatic hydrolysis yield especially in maize, due to its high content of soluble sugars that were already converted to acids during storage. Urea-based preservation significantly increased the enzymatic hydrolysability of hemp. Hemp, preserved with urea, produced the highest carbohydrate increase of 46% in enzymatic hydrolysis as compared to the fresh material. Alkaline pretreatment conditions of hemp improved also the methane yields. Conclusions The results of the present work show that ensiling and alkaline preservation of fresh crop materials are useful pretreatment methods for methane production. Improvements in enzymatic hydrolysis were also promising. While all three crops still require a more powerful pretreatment to release the maximum amount of carbohydrates, anaerobic preservation is clearly a suitable storage and pretreatment method prior to production of platform sugars from fresh crops. PMID:21771298
Nakayama, Hiroshi; Kambara, Syunichiro; Iseki, Tomoya; Kanto, Ryo; Kurosaka, Kenji; Yoshiya, Shinichi
2017-10-01
To compare the early postoperative outcomes and complications of double-bundle anterior cruciate ligament (ACL) reconstruction with and without remnant preservation. The study population comprised 125 consecutive knees that underwent double-bundle ACL reconstruction using hamstring autograft. Among the 125 knees, remnant preservation was indicated for 50 knees, while standard double-bundle reconstruction was performed in the remaining 75 knees. Postoperative evaluations included heel-height difference (HHD) at periodical follow-ups, number of knees requiring arthroscopic debridement due to problematic extension loss within six months, re-injury within one year, graft status upon second-look arthroscopy, and clinical examinations by Lysholm score and KT measurement at one year. All patients could be followed up for a minimum of one year after surgery. When the results obtained from both groups were compared, HHD values were significantly larger in the preservation group at three and six months, and the rate of knees requiring arthroscopic debridement was also higher in this group (12% versus 4.0%). Graft status on second-look arthroscopy was considered to be good for 92% of the knees in the preservation group versus 59% in the non-preservation group. Re-injury rates within one year were 2.0% in the preservation group and 5.3% in the non-preservation group. No significant differences in clinical examinations were found between the groups at one year. Remnant preservation in double-bundle hamstring autograft ACL reconstruction may enhance tissue healing; however, retention of the remnant with its full volume resulted in an increased incidence of postoperative problematic extension loss. Copyright © 2017 Elsevier B.V. All rights reserved.
Plants of the Big Cypress National Preserve, Florida
Muss, J.D.; Austin, D.F.; Snyder, J.R.
2003-01-01
A new survey of the Big Cypress National Preserve shows that the vascular flora consists of 145 families and 851 species. Of these, 72 are listed by the State of Florida as endangered or threatened plants, while many others are on the margins of their ranges. The survey also shows 158 species of exotic plants within the Preserve, some of which imperil native species by competing with them. Finally, we compare the flora of the Big Cypress National Preserve with those of the nearby Fakahatchee Strand State Preserve and the Everglades National Park. Although Big Cypress is less than half the size of Everglades National Park, it has 90% of the native species richness (693 vs. 772).
Temperature and oxygenation during organ preservation: friends or foes?
Gilbo, Nicholas; Monbaliu, Diethard
2017-06-01
The liberalization of donor selection criteria in organ transplantation, with the increased use of suboptimal grafts, has stimulated interest in ischemia-reperfusion injury prevention and graft reconditioning. Organ preservation technologies are changing considerably, mostly through the reintroduction of dynamic machine preservation. Here, we review the current evidence on the role of temperature and oxygenation during dynamic machine preservation. A large but complex body of evidence exists and comparative studies are few. Oxygenation seems to support an advantageous effect in hypothermic machine preservation and is mandatory in normothermic machine preservation, although in the latter, supraphysiological oxygen tensions should be avoided. High-risk grafts, such as suboptimal organs, may optimally benefit from oxygenated perfusion conditions that support metabolism and activate mechanisms of repair such as subnormothermic machine preservation, controlled oxygenated rewarming, and normothermic machine preservation. For lower risk grafts, oxygenation during hypothermic machine preservation may sufficiently reduce injuries and recharge the cellular energy to secure functional recovery after transplantation. The relationship between temperature and oxygenation in organ preservation is more complex than physiological laws would suggest. Rather than one default perfusion temperature/oxygenation standard, perfusion protocols should be tailored for specific needs of grafts of different quality.
Tomita, Ryouichi
2005-01-01
For early gastric cancer total gastrectomy (TG) has so far been essentially unavoidable. We performed the nearly TG reconstructed by single jejunal interposition preservation of the vagal nerve, lower esophageal sphincter (LES) and pyloric sphincter (D1 or D2 lymph node dissection, curability A) as a function-preserving surgical technique (i.e. NTG) to improve postoperative quality of life (QOL). In this report, the application criteria and points of the technique are outlined. QOL in patients after NTG was also compared with those after TG. Sixteen subjects who underwent NTG (12 men and 4 women subjects at age 30 to 70 years, mean 55.6 years) were interviewed to inquire about abdominal symptoms and compared with 20 patients after conventional TG (excision with D2 lymph node, radical curability A) reconstructed by single jejunal interposition without preserving the vagal nerve, LES, and pyloric sphincter (i.e. TGI; 14 men and 6 women at age 26 to 70 years, mean 54.8 years). The former was named group A and the latter group B. Included were cases with early cancer localizing at the upper third and middle stomach, 2cm or further in distance from oral-side margin of the cancer to esophagogastric mucosal junction; and 3.5cm or further in distance from anal-side margin of the cancer to the pyloric sphincter. In excision with the lymph node, hepatic and celiac branches were preserved. To preserve LES, the abdominal esophagus was completely preserved. The pyloric antrum was also preserved at 1.5cm from the pyloric sphincter. The substitute stomach was created as a 30-cm-long single jejunal segment having orthodromic peristaltic movement. The operative procedure in group A significantly improved postoperative gastrointestinal symptoms such as appetite loss (p=0.0004), weight loss (p=0.0369), reflux esophagitis (RE) (p=0.0163), early dumping syndrome (p=0.0163), endoscopic RE (p=0.0311), and postgastrectomy cholecystolithiasis (p=0.0163) compared with group B. Oral intake per one meal 5 years after operation compared with that before operation was better in group A than in group B (p=0.0703). Postoperative epigastric fullness was significantly detected in group A compared with group B (p=0.0072). The proposed surgical technique of NTG is a function-preserving surgery appropriate to improve QOL of subjects with early gastric cancer. There was a defect in this technique of postprandial feeling of epigastric fullness. We think that a gut motility improvement agent is necessary to improve postprandial epigastric fullness after NTG.
Foveation: an alternative method to simultaneously preserve privacy and information in face images
NASA Astrophysics Data System (ADS)
Alonso, Víctor E.; Enríquez-Caldera, Rogerio; Sucar, Luis Enrique
2017-03-01
This paper presents a real-time foveation technique proposed as an alternative method for image obfuscation while simultaneously preserving privacy in face deidentification. Relevance of the proposed technique is discussed through a comparative study of the most common distortions methods in face images and an assessment on performance and effectiveness of privacy protection. All the different techniques presented here are evaluated when they go through a face recognition software. Evaluating the data utility preservation was carried out under gender and facial expression classification. Results on quantifying the tradeoff between privacy protection and image information preservation at different obfuscation levels are presented. Comparative results using the facial expression subset of the FERET database show that the technique achieves a good tradeoff between privacy and awareness with 30% of recognition rate and a classification accuracy as high as 88% obtained from the common figures of merit using the privacy-awareness map.
NASA Astrophysics Data System (ADS)
Xu, Wenjun; Tang, Chen; Zheng, Tingyue; Qiu, Yue
2018-07-01
Oriented partial differential equations (OPDEs) have been demonstrated to be a powerful tool for preserving the integrity of fringes while filtering electronic speckle pattern interferometry (ESPI) fringe patterns. However, the main drawback of OPDEs-based methods is that many iterations are often needed, which causes the change in the shape of fringes. Change in the shape of fringes will affect the accuracy of subsequent fringe analysis. In this paper, we focus on preserving the shape of fringes while filtering, suggested here for the first time. We propose a shape-preserving OPDE for ESPI fringe patterns denoising by introducing a new fidelity term to the previous second-order single oriented PDE (SOOPDE). In our proposed fidelity term, the evolution image is subtracted from the shrinkage result of original noisy image by shearlet transform. Our proposed shape-preserving OPDE is capable of eliminating noise effectively, keeping the integrity of fringes, and more importantly, preserving the shape of fringes. We test the proposed shape-preserving OPDE on three computer-simulated and three experimentally obtained ESPI fringe patterns with poor quality. Furthermore, we compare our model with three representative filtering methods, including the widely used SOOPDE, shearlet transform and coherence-enhancing diffusion (CED). We also compare our proposed fidelity term with the traditional fidelity term. Experimental results show that the proposed shape-preserving OPDE not only yields filtered images with visual quality on par with those by CED which is the state-of-the-art method for ESPI fringe patterns denoising, but also keeps the shape of ESPI fringe patterns.
Improved biochemical preservation of lung slices during cold storage.
Bull, D A; Connors, R C; Reid, B B; Albanil, A; Stringham, J C; Karwande, S V
2000-05-15
Development of lung preservation solutions typically requires whole-organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that lung slices could be used to assess preservation of biochemical function during cold storage. Whole rat lungs were precision cut into slices with a thickness of 500 microm and preserved at 4 degrees C in the following solutions: University of Wisconsin (UW), Euro-Collins (EC), low-potassium-dextran (LPD), Kyoto (K), normal saline (NS), or a novel lung preservation solution (NPS) developed using this model. Lung biochemical function was assessed by ATP content (etamol ATP/mg wet wt) and capacity for protein synthesis (cpm/mg protein) immediately following slicing (0 h) and at 6, 12, 18, and 24 h of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as means +/- SD. ATP content was significantly higher in the lung slices stored in NPS compared with all other solutions at each time point (P < 0.0001). Protein synthesis was significantly higher in the lung slices stored in NPS compared with all other solutions at 6, 12, and 18 h of preservation (P < 0.05). This lung slice model allows the rapid and efficient screening of lung preservation solutions and their components using quantifiable biochemical endpoints. Using this model, we have developed a novel solution that improves the biochemical preservation of lung slices during cold storage. Copyright 2000 Academic Press.
Chisvert, A; Salvador, A; Pascual-Martí, M C; March, J G
2001-04-01
Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LOD are adequate to the analysis requirements. The sample frequency obtained by FI is three-fold higher than that of SI analysis. SI is less reagent-consuming than FI.
A novel approach for small sample size family-based association studies: sequential tests.
Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan
2011-08-01
In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.
Sequential processing deficits in schizophrenia: relationship to neuropsychology and genetics.
Hill, S Kristian; Bjorkquist, Olivia; Carrathers, Tarra; Roseberry, Jarett E; Hochberger, William C; Bishop, Jeffrey R
2013-12-01
Utilizing a combination of neuropsychological and cognitive neuroscience approaches may be essential for characterizing cognitive deficits in schizophrenia and eventually assessing cognitive outcomes. This study was designed to compare the stability of select exemplars for these approaches and their correlations in schizophrenia patients with stable treatment and clinical profiles. Reliability estimates for serial order processing were comparable to neuropsychological measures and indicate that experimental serial order processing measures may be less susceptible to practice effects than traditional neuropsychological measures. Correlations were moderate and consistent with a global cognitive factor. Exploratory analyses indicated a potentially critical role of the Met allele of the Catechol-O-methyltransferase (COMT) Val158Met polymorphism in externally paced sequential recall. Experimental measures of serial order processing may reflect frontostriatal dysfunction and be a useful supplement to large neuropsychological batteries. © 2013.
Sequential Processing Deficits in Schizophrenia: Relationship to Neuropsychology and Genetics
Hill, S. Kristian; Bjorkquist, Olivia; Carrathers, Tarra; Roseberry, Jarett E.; Hochberger, William C.; Bishop, Jeffrey R.
2014-01-01
Utilizing a combination of neuropsychological and cognitive neuroscience approaches may be essential for characterizing cognitive deficits in schizophrenia and eventually assessing cognitive outcomes. This study was designed to compare the stability of select exemplars for these approaches and their correlations in schizophrenia patients with stable treatment and clinical profiles. Reliability estimates for serial order processing were comparable to neuropsychological measures and indicate that experimental serial order processing measures may be less susceptible to practice effects than traditional neuropsychological measures. Correlations were moderate and consistent with a global cognitive factor. Exploratory analyses indicated a potentially critical role of the Met allele of the Catechol-O-methyltransferase (COMT) Val158Met polymorphism in externally paced sequential recall. Experimental measures of serial order processing may reflect frontostriatal dysfunction and be a useful supplement to large neuropsychological batteries. PMID:24119464
Kronberg, J.W.
1992-06-02
A sequential power-up circuit for starting several electrical load elements in series to avoid excessive current surge, comprising a voltage ramp generator and a set of voltage comparators, each comparator having a different reference voltage and interfacing with a switch that is capable of turning on one of the load elements. As the voltage rises, it passes the reference voltages one at a time and causes the switch corresponding to that voltage to turn on its load element. The ramp is turned on and off by a single switch or by a logic-level electrical signal. The ramp rate for turning on the load element is relatively slow and the rate for turning the elements off is relatively fast. Optionally, the duration of each interval of time between the turning on of the load elements is programmable. 2 figs.
Thuerlimann, Beat
2007-01-01
The BIG 1-98 trial is a large, randomized, independently conducted clinical trial designed to compare the efficacy of upfront letrozole versus tamoxifen monotherapy and to compare sequential or up-front use of letrozole and/or tamoxifen as an early adjuvant therapy for patients with early breast cancer. We report on the results from the primary core analysis of the BIG 1-98 trial of 8,010 patients, which compares monotherapy with letrozole versus tamoxifen. This pre-planned core analysis allowed the use of patient data from the monotherapy arms of letrozole and tamoxifen and from the sequential arms prior to the drug switch point. Patients randomized to letrozole had a 19% improved disease-free survival (hazard ratio [HR] = 0.81; P = 0.003), due especially to reduced distant metastases (HR = 0.73; P = 0.001). A 14% risk reduction of fatal events in favor of letrozole was also observed (P = NS). The results from the monotherapy arms alone confirmed the findings from the primary core analysis. Based on the results from this trial, the aromatase inhibitor letrozole (Femara®) is currently recommended as a part of standard adjuvant therapy for postmenopausal women with endocrine-responsive breast cancer and has recently been approved in the early adjuvant setting in both Europe and the United States. A subsequent analysis after additional follow-up will address the question of monotherapy versus sequential therapy. PMID:17912636
Robertson, Audra D; Missmer, Stacey A; Ginsburg, Elizabeth S
2011-02-01
To evaluate embryo yield after IVF in patients undergoing embryo banking before chemotherapy. A retrospective cohort study. Hospital-based academic medical center. Thirty-eight women diagnosed with cancer or autoimmune disease presenting for IVF cycles, with or without intracytoplasmic sperm injection (ICSI), for embryo cryopreservation before any therapy were compared with 921 presumably fertile women undergoing IVF for male factor infertility from January 2001 through October 2007. Standard IVF or ICSI protocol, embryo freezing, and ET. The number of 2 pronuclear (2PN) embryos created and suitable for cryopreservation or transfer. No statistically significant differences were observed between preservation and male factor groups for number of embryos, number of oocytes, or amount of gonadotropin needed to stimulate follicular development. Peak serum E(2) levels were significantly lower for women with disease-seeking fertility preservation. Women facing chemotherapy as treatment for cancer or systemic autoimmune disease infrequently undergo fertility preservation. If offered this potentially fertility-preserving option, these data suggest equivalent embryo yield compared with women with infertile male partners. Our data report no significant complications in subsequent births in those who sought fertility preservation, which is informative and encouraging for these women and their providers. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
A three-dimensional quality-guided phase unwrapping method for MR elastography
NASA Astrophysics Data System (ADS)
Wang, Huifang; Weaver, John B.; Perreard, Irina I.; Doyley, Marvin M.; Paulsen, Keith D.
2011-07-01
Magnetic resonance elastography (MRE) uses accumulated phases that are acquired at multiple, uniformly spaced relative phase offsets, to estimate harmonic motion information. Heavily wrapped phase occurs when the motion is large and unwrapping procedures are necessary to estimate the displacements required by MRE. Two unwrapping methods were developed and compared in this paper. The first method is a sequentially applied approach. The three-dimensional MRE phase image block for each slice was processed by two-dimensional unwrapping followed by a one-dimensional phase unwrapping approach along the phase-offset direction. This unwrapping approach generally works well for low noise data. However, there are still cases where the two-dimensional unwrapping method fails when noise is high. In this case, the baseline of the corrupted regions within an unwrapped image will not be consistent. Instead of separating the two-dimensional and one-dimensional unwrapping in a sequential approach, an interleaved three-dimensional quality-guided unwrapping method was developed to combine both the two-dimensional phase image continuity and one-dimensional harmonic motion information. The quality of one-dimensional harmonic motion unwrapping was used to guide the three-dimensional unwrapping procedures and it resulted in stronger guidance than in the sequential method. In this work, in vivo results generated by the two methods were compared.
Takayanagi, Toshio; Inaba, Yuya; Kanzaki, Hiroyuki; Jyoichi, Yasutaka; Motomizu, Shoji
2009-09-15
Catalytic effect of metal ions on luminol chemiluminescence (CL) was investigated by sequential injection analysis (SIA). The SIA system was set up with two solenoid micropumps, an eight-port selection valve, and a photosensor module with a fountain-type chemiluminescence cell. The SIA system was controlled and the CL signals were collected by a LabVIEW program. Aqueous solutions of luminol, H(2)O(2), and a sample solution containing metal ion were sequentially aspirated to the holding coil, and the zones were immediately propelled to the detection cell. After optimizing the parameters using 1 x 10(-5)M Fe(3+) solution, catalytic effect of some metal species was compared. Among 16 metal species examined, relatively strong CL responses were obtained with Fe(3+), Fe(2+), VO(2+), VO(3)(-), MnO(4)(-), Co(2+), and Cu(2+). The limits of detection by the present SIA system were comparable to FIA systems. Permanganate ion showed the highest CL sensitivity among the metal species examined; the calibration graph for MnO(4)(-) was linear at the concentration level of 10(-8)M and the limit of detection for MnO(4)(-) was 4.0 x 10(-10)M (S/N=3).
El Emam, Dalia Sabry; Farag, Rania Kamel; Abouelkheir, Hossam Youssef
2016-01-01
Aim. To compare objective and subjective outcome after simultaneous wave front guided (WFG) PRK and accelerated corneal cross-linking (CXL) in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods. 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results. All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P < 0.001). A significant improvement was observed in keratometric and Q values. The improvement in all parameters was stable till the end of follow-up. Likewise, no significant difference was determined in between the 2 groups in any of recorded parameters. Subjective data revealed similarly significant improvement in both groups. Conclusions. WFG PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure. PMID:28127465
Abou Samra, Waleed Ali; El Emam, Dalia Sabry; Farag, Rania Kamel; Abouelkheir, Hossam Youssef
2016-01-01
Aim . To compare objective and subjective outcome after simultaneous wave front guided (WFG) PRK and accelerated corneal cross-linking (CXL) in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods . 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results . All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P < 0.001). A significant improvement was observed in keratometric and Q values. The improvement in all parameters was stable till the end of follow-up. Likewise, no significant difference was determined in between the 2 groups in any of recorded parameters. Subjective data revealed similarly significant improvement in both groups. Conclusions . WFG PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure.
Development of a syringe pump assisted dynamic headspace sampling technique for needle trap device.
Eom, In-Yong; Niri, Vadoud H; Pawliszyn, Janusz
2008-07-04
This paper describes a new approach that combines needle trap devices (NTDs) with a dynamic headspace sampling technique (purge and trap) using a bidirectional syringe pump. The needle trap device is a 22-G stainless steel needle 3.5-in. long packed with divinylbenzene sorbent particles. The same sized needle, without packing, was used for purging purposes. We chose an aqueous mixture of benzene, toluene, ethylbenzene, and p-xylene (BTEX) and developed a sequential purge and trap (SPNT) method, in which sampling (trapping) and purging cycles were performed sequentially by the use of syringe pump with different distribution channels. In this technique, a certain volume (1 mL) of headspace was sequentially sampled using the needle trap; afterwards, the same volume of air was purged into the solution at a high flow rate. The proposed technique showed an effective extraction compared to the continuous purge and trap technique, with a minimal dilution effect. Method evaluation was also performed by obtaining the calibration graphs for aqueous BTEX solutions in the concentration range of 1-250 ng/mL. The developed technique was compared to the headspace solid-phase microextraction method for the analysis of aqueous BTEX samples. Detection limits as low as 1 ng/mL were obtained for BTEX by NTD-SPNT.
Cherry, Kevin M; Peplinski, Brandon; Kim, Lauren; Wang, Shijun; Lu, Le; Zhang, Weidong; Liu, Jianfei; Wei, Zhuoshi; Summers, Ronald M
2015-01-01
Given the potential importance of marginal artery localization in automated registration in computed tomography colonography (CTC), we have devised a semi-automated method of marginal vessel detection employing sequential Monte Carlo tracking (also known as particle filtering tracking) by multiple cue fusion based on intensity, vesselness, organ detection, and minimum spanning tree information for poorly enhanced vessel segments. We then employed a random forest algorithm for intelligent cue fusion and decision making which achieved high sensitivity and robustness. After applying a vessel pruning procedure to the tracking results, we achieved statistically significantly improved precision compared to a baseline Hessian detection method (2.7% versus 75.2%, p<0.001). This method also showed statistically significantly improved recall rate compared to a 2-cue baseline method using fewer vessel cues (30.7% versus 67.7%, p<0.001). These results demonstrate that marginal artery localization on CTC is feasible by combining a discriminative classifier (i.e., random forest) with a sequential Monte Carlo tracking mechanism. In so doing, we present the effective application of an anatomical probability map to vessel pruning as well as a supplementary spatial coordinate system for colonic segmentation and registration when this task has been confounded by colon lumen collapse. Published by Elsevier B.V.
Performance Analysis of Ranging Techniques for the KPLO Mission
NASA Astrophysics Data System (ADS)
Park, Sungjoon; Moon, Sangman
2018-03-01
In this study, the performance of ranging techniques for the Korea Pathfinder Lunar Orbiter (KPLO) space communication system is investigated. KPLO is the first lunar mission of Korea, and pseudo-noise (PN) ranging will be used to support the mission along with sequential ranging. We compared the performance of both ranging techniques using the criteria of accuracy, acquisition probability, and measurement time. First, we investigated the end-to-end accuracy error of a ranging technique incorporating all sources of errors such as from ground stations and the spacecraft communication system. This study demonstrates that increasing the clock frequency of the ranging system is not required when the dominant factor of accuracy error is independent of the thermal noise of the ranging technique being used in the system. Based on the understanding of ranging accuracy, the measurement time of PN and sequential ranging are further investigated and compared, while both techniques satisfied the accuracy and acquisition requirements. We demonstrated that PN ranging performed better than sequential ranging in the signal-to-noise ratio (SNR) regime where KPLO will be operating, and we found that the T2B (weighted-voting balanced Tausworthe, voting v = 2) code is the best choice among the PN codes available for the KPLO mission.
Rivera, Jessica C; Beachler, Jason A
2018-01-23
Post-traumatic arthritis (PTA) is characterized by the deterioration of articular cartilage temporally associated with an articular injury. With a paucity of literature comparing joint preservation techniques, we performed a systematic review of the literature intending to describe and summarize the results of ankle distraction arthroplasty as it compares with studies on tibio-talar microfracture, allograft, and autograft for ankle joint preservation in the post-traumatic population under 50 years of age. Research databases were searched and abstracts screened for relevance on our topic of interest. Abstracts meeting screening criteria with high interobserver reliability underwent full-manuscript review and coding for pertinent citation, study level, treatment, and outcome variables. Outcome variables for patient-reported pain scales, validated outcome measurement tools, radiographic progression, reoperation/re-treatment rates, and complication rates were recorded. Out of 105 unique citations, 10 publications were included. The distraction arthroplasty studies had 36 out of 181 patients requiring reoperation for complications (19.9%), while other joint-preserving procedures studies had 40 out of 177 patients requiring reoperations for complications (22.6%). Clinical outcome scores at mean follow-up time ranging from 2 to 10 years between studies were similar. Reported results for a variety of cartilage preservation procedures, including distraction arthroplasty, are satisfactory and reoperation rates for complication are similar. Limitations in available data and underlying study quality affect synthesis of the results therein. While distraction arthroplasty is an option for cartilage preservation in patients with PTA of the ankle, the technique is highly specialized which may affect the external validity. III.
Bochimoto, Hiroki; Matsuno, Naoto; Ishihara, Yo; Shonaka, Tatsuya; Koga, Daisuke; Hira, Yoshiki; Nishikawa, Yuji; Furukawa, Hiroyuki; Watanabe, Tsuyoshi
2017-01-01
The effects of warm machine perfusion preservation of liver grafts donated after cardiac death on the intracellular three-dimensional ultrastructure of the organelles in hepatocytes remain unclear. Here we analyzed comparatively the ultrastructure of the endomembrane systems in porcine hepatocytes under warm ischemia and successive hypothermic and midthermic machine perfusion preservation, a type of the warm machine perfusion. Porcine liver grafts which had a warm ischemia time of 60 minutes were perfused for 4 hours with modified University of Wisconsin gluconate solution. Group A grafts were preserved with hypothermic machine perfusion preservation at 8°C constantly for 4 hours. Group B grafts were preserved with rewarming up to 22°C by warm machine perfusion preservation for 4 hours. An analysis of hepatocytes after 60 minutes of warm ischemia by scanning electron microscope revealed the appearance of abnormal vacuoles and invagination of mitochondria. In the hepatocytes preserved by subsequent hypothermic machine perfusion preservation, strongly swollen mitochondria were observed. In contrast, the warm machine perfusion preservation could preserve the functional appearance of mitochondria in hepatocytes. Furthermore, abundant vacuoles and membranous structures sequestrating cellular organelles like autophagic vacuoles were frequently observed in hepatocytes after warm machine perfusion preservation. In conclusion, the ultrastructure of the endomembrane systems in the hepatocytes of liver grafts changed in accordance with the temperature conditions of machine perfusion preservation. In addition, temperature condition of the machine perfusion preservation may also affect the condition of the hepatic graft attributed to autophagy systems, and consequently alleviate the damage of the hepatocytes.
Kania, Dramane; Sangaré, Lassana; Sakandé, Jean; Koanda, Abdoulaye; Nébié, Yacouba Kompingnin; Zerbo, Oumarou; Combasséré, Alain Wilfried; Guissou, Innocent Pierre; Rouet, François
2009-10-01
In Africa where blood-borne agents are highly prevalent, cheaper and feasible alternative strategies for blood donations testing are specifically required. From May to August 2002, 500 blood donations from Burkina Faso were tested for hepatitis B surface antigen (HBsAg), human immunodeficiency virus (HIV), syphilis, and hepatitis C virus (HCV) according to two distinct strategies. The first strategy was a conventional simultaneous screening of these four blood-borne infectious agents on each blood donation by using single-marker assays. The second strategy was a sequential screening starting by HBsAg. HBsAg-nonreactive blood donations were then further tested for HIV. If nonreactive, they were further tested for syphilis. If nonreactive, they were finally assessed for HCV antibodies. The accuracy and cost-effectiveness of the two strategies were compared. By using the simultaneous strategy, the seroprevalences of HBsAg, HIV, syphilis, and HCV among blood donors in Ouagadougou were estimated to be 19.2, 9.8, 1.6, and 5.2%. No significant difference of HIV, syphilis, and HCV prevalence rates was observed by using the sequential strategy (9.2, 1.9, and 4.7%, respectively). Whatever the strategy used, 157 blood donations (31.4%) were found to be reactive for at least one transfusion-transmissible agent and were thus discarded. The sequential strategy allowed a cost decrease of euro 908.6, compared to the simultaneous strategy. Given that approximately there are 50,000 blood donations annually in Burkina Faso, the money savings reached potentially euro 90,860. In resource-limited settings, the implementation of a sequential strategy appears as a pragmatic solution to promote safe blood supply and ensure sustainability of the system.
2014-01-01
Background End-to-side anastomoses to connect the distal end of the great saphenous vein (GSV) to small target coronary arteries are commonly performed in sequential coronary artery bypass grafting (CABG). However, the oversize diameter ratio between the GSV and small target vessels at end-to-side anastomoses might induce adverse hemodynamic condition. The purpose of this study was to describe a distal end side-to-side anastomosis technique and retrospectively compare the effect of distal end side-to-side versus end-to-side anastomosis on graft flow characteristics. Methods We performed side-to-side anastomoses to connect the distal end of the GSV to small target vessels on 30 patients undergoing off-pump sequential CABG in our hospital between October 2012 and July 2013. Among the 30 patients, end-to-side anastomoses at the distal end of the GSV were initially performed on 14 patients; however, due to poor graft flow, those anastomoses were revised into side-to-side anastomoses. We retrospectively compared the intraoperative graft flow characteristics of the end-to-side versus side-to-side anastomoses in the 14 patients. The patient outcomes were also evaluated. Results We found that the side-to-side anastomosis reconstruction improved intraoperative flow and reduced pulsatility index in all the 14 patients significantly. The 16 patients who had the distal end side-to-side anastomoses performed directly also exhibited satisfactory intraoperative graft flow. Three-month postoperative outcomes for all the patients were satisfactory. Conclusions Side-to-side anastomosis at the distal end of sequential vein grafts might be a promising strategy to connect small target coronary arteries to the GSV. PMID:24884776
Hennings, Justin M.; Zimmer, Randall L.; Nabli, Henda; Davis, J. Wade; Sutovsky, Peter; Sutovsky, Miriam; Sharpe-Timms, Kathy L.
2015-01-01
Objective: Validate single versus sequential culture media for murine embryo development. Design: Prospective laboratory experiment. Setting: Assisted Reproduction Laboratory. Animals: Murine embryos. Interventions: Thawed murine zygotes cultured for 3 or 5 days (d3 or d5) in single or sequential embryo culture media developed for human in vitro fertilization. Main Outcome Measures: On d3, zygotes developing to the 8 cell (8C) stage or greater were quantified using 4’,6-diamidino-2-phenylindole (DAPI), and quality was assessed by morphological analysis. On d5, the number of embryos reaching the blastocyst stage was counted. DAPI was used to quantify total nuclei and inner cell mass nuclei. Localization of ubiquitin C-terminal hydrolase L1 (UCHL1) and ubiquitin C-terminal hydrolase L3 (UCHL3) was reference points for evaluating cell quality. Results: Comparing outcomes in single versus to sequential media, the odds of embryos developing to the 8C stage on d3 were 2.34 time greater (P = .06). On d5, more embryos reached the blastocyst stage (P = <.0001), hatched, and had significantly more trophoblast cells (P = .005) contributing to the increased total cell number. Also at d5, localization of distinct cytoplasmic UCHL1 and nuclear UCHL3 was found in high-quality hatching blastocysts. Localization of UCHL1 and UCHL3 was diffuse and inappropriately dispersed throughout the cytoplasm in low-quality nonhatching blastocysts. Conclusions: Single medium yields greater cell numbers, an increased growth rate, and more hatching of murine embryos. Cytoplasmic UCHL1 and nuclear UHCL3 localization patterns were indicative of embryo quality. Our conclusions are limited to murine embryos but one might speculate that single medium may also be more beneficial for human embryo culture. Human embryo studies are needed. PMID:26668049
Hennings, Justin M; Zimmer, Randall L; Nabli, Henda; Davis, J Wade; Sutovsky, Peter; Sutovsky, Miriam; Sharpe-Timms, Kathy L
2016-03-01
Validate single versus sequential culture media for murine embryo development. Prospective laboratory experiment. Assisted Reproduction Laboratory. Murine embryos. Thawed murine zygotes cultured for 3 or 5 days (d3 or d5) in single or sequential embryo culture media developed for human in vitro fertilization. On d3, zygotes developing to the 8 cell (8C) stage or greater were quantified using 4',6-diamidino-2-phenylindole (DAPI), and quality was assessed by morphological analysis. On d5, the number of embryos reaching the blastocyst stage was counted. DAPI was used to quantify total nuclei and inner cell mass nuclei. Localization of ubiquitin C-terminal hydrolase L1 (UCHL1) and ubiquitin C-terminal hydrolase L3 (UCHL3) was reference points for evaluating cell quality. Comparing outcomes in single versus to sequential media, the odds of embryos developing to the 8C stage on d3 were 2.34 time greater (P = .06). On d5, more embryos reached the blastocyst stage (P = <.0001), hatched, and had significantly more trophoblast cells (P = .005) contributing to the increased total cell number. Also at d5, localization of distinct cytoplasmic UCHL1 and nuclear UCHL3 was found in high-quality hatching blastocysts. Localization of UCHL1 and UCHL3 was diffuse and inappropriately dispersed throughout the cytoplasm in low-quality nonhatching blastocysts. Single medium yields greater cell numbers, an increased growth rate, and more hatching of murine embryos. Cytoplasmic UCHL1 and nuclear UHCL3 localization patterns were indicative of embryo quality. Our conclusions are limited to murine embryos but one might speculate that single medium may also be more beneficial for human embryo culture. Human embryo studies are needed. © The Author(s) 2015.
Dong, Jian; Xin, Jianfeng; Shen, Wenbin; Chen, Xiaobai; Wen, Tingguo; Zhang, Chunyan; Wang, Rengui
2018-04-01
The objective of our study was to investigate the clinical value of diagnostic lymphangiography followed by sequential CT examinations in patients with idiopathic chyluria. Thirty-six patients with idiopathic chyluria underwent unipedal diagnostic lymphangiography and then underwent sequential CT examinations. The examinations were reviewed separately by two radiologists. Abnormal distribution of contrast medium, lymphourinary leakages, and retrograde flow were noted, and the range and distribution of lymphatic vessel lesions were recorded. The stage of idiopathic chyluria based on CT findings and the stage based on clinical findings were compared. Therapeutic management and follow-up were recorded. Statistical analyses were performed. Compared with CT studies performed after lymphangiography, diagnostic lymphangiography showed a unique capability to depict lymphourinary leakages in three patients. Lymphourinary fistulas and abnormal dilated lymphatic vessels were found in and around kidney in all patients. CT depicted retrograde flow of lymph fluid in 47.2% of patients. The consistency in staging chyluria based on CT findings and clinical findings was fair (κ = 0.455). Twenty-nine patients underwent conservative therapy, and seven underwent surgery. Surgical therapy was superior to conservative management (no recurrence, 85.7% of patients who underwent surgery vs 62.1% of patients who underwent conservative therapy; p = 0.025). From assessing the drainage of contrast medium on unipedal diagnostic lymphangiography and the redistribution of contrast medium on sequential CT examinations, it is possible to detect the existence of lymphourinary fistulas, the precise location of lymphatic anomalies, the distribution of collateral lymphatic vessels, and hydrodynamic pressure abnormality in the lymph circulation in patients with idiopathic chyluria. CT staging of chyluria provides additional information that can be used to guide therapeutic management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagar, Himanshu; Boothe, Dustin; Parikh, Amar
2013-11-15
Purpose: To evaluate the tolerability and toxicity of administering vaginal brachytherapy (VB) concurrently during chemotherapy compared with the sequential approach for patients with endometrial cancer. Methods and Materials: A retrospective analysis of 372 surgically staged patients with endometrial cancer American Joint Committee on Cancer 2009 stages I to IV treated with adjuvant postoperative radiation therapy (RT) at our institution from 2001 to 2012 was conducted. All patients received VB + external beam RT (EBRT) + 6 cycles of adjuvant carboplatin- and paclitaxel-based chemotherapy. The VB mean dose was 15.08 Gy (range, 15-20 Gy), with 3 to 4 weekly applications, andmore » the EBRT mean dose was 45 Gy delivered with 3-dimensional or intensity modulated RT techniques. Hematologic, gastrointestinal (GI), and genitourinary (GU) toxicities were assessed by Common Toxicity Criteria (CTC) and compared between sequential and concurrent chemotherapy and VB schedules. Results: Among patients who received RT and adjuvant chemotherapy, 180 of 372 patients (48%) received RT sandwiched between cycles 3 and 4 of chemotherapy. A separate group of 192 patients (52%) were treated with VB during the first 3 cycles of chemotherapy, with a weekly application on nonchemotherapy days, and received the EBRT portion in a sandwiched fashion. Patients treated with VB during chemotherapy had a decreased overall treatment time by 4 weeks (P<.001; 95% confidence interval: 3.99-4.02) and sustained no difference in CTC-graded acute hematologic, GI, or GU toxicities in comparison with the patients treated with VB and chemotherapy in a sequential manner (P>.05). CTC grade 3 or 4 hematologic, GI, and GU toxicities were zero. Conclusions: VB during chemotherapy is well tolerated, decreases overall treatment time, and does not render more toxicity than the sequential regimen.« less
Egerup, Pia; Lindschou, Jane; Gluud, Christian; Christiansen, Ole Bjarne
2015-01-01
Background Immunological disturbances are hypothesised to play a role in recurrent miscarriage (RM) and therefore intravenous immunoglubulins (IVIg) have been tested in RM patients. Objectives The objectives were to investigate the benefits and harms of IVIg versus placebo, no intervention, or treatment as usual in women with RM. Search Strategy We searched the published literature in all relevant databases. Selection Criteria Randomised trials investigating IVIg versus placebo, no intervention, or treatment as usual in women with RM. Data Collection and Analysis We undertook meta-analyses of aggregated data and individual patient data using a two-step approach, and we conducted bias domain assessments and trial sequential analyses to assess the risks of systematic and random errors. Main Results We identified 11 randomised clinical trials. No significant difference in the frequency of no live birth was found when IVIg was compared with placebo or treatment as usual (RR 0.92, 95% CI 0.75–1.12, p = 0.42). Trial sequential analysis showed that the required information size of 1,008 participants was not obtained. IVIg compared with placebo seems to increase the risk of adverse events. Subgroup analysis suggests that women with RM after a birth (secondary RM) seemed most likely to obtain a potential beneficial effect of IVIg (RR for no live birth 0.77, 95%CI 0.58–1.02, p = 0.06), however, trial sequential analysis showed that insufficient information is presently accrued. Conclusion We cannot recommend or refute IVIg in women with RM. IVIg should therefore be assessed in further randomised clinical trials with positive outcomes before any clinical use is considered. PMID:26517123
Egerup, Pia; Lindschou, Jane; Gluud, Christian; Christiansen, Ole Bjarne
2015-01-01
Immunological disturbances are hypothesised to play a role in recurrent miscarriage (RM) and therefore intravenous immunoglubulins (IVIg) have been tested in RM patients. The objectives were to investigate the benefits and harms of IVIg versus placebo, no intervention, or treatment as usual in women with RM. We searched the published literature in all relevant databases. Randomised trials investigating IVIg versus placebo, no intervention, or treatment as usual in women with RM. We undertook meta-analyses of aggregated data and individual patient data using a two-step approach, and we conducted bias domain assessments and trial sequential analyses to assess the risks of systematic and random errors. We identified 11 randomised clinical trials. No significant difference in the frequency of no live birth was found when IVIg was compared with placebo or treatment as usual (RR 0.92, 95% CI 0.75-1.12, p = 0.42). Trial sequential analysis showed that the required information size of 1,008 participants was not obtained. IVIg compared with placebo seems to increase the risk of adverse events. Subgroup analysis suggests that women with RM after a birth (secondary RM) seemed most likely to obtain a potential beneficial effect of IVIg (RR for no live birth 0.77, 95%CI 0.58-1.02, p = 0.06), however, trial sequential analysis showed that insufficient information is presently accrued. We cannot recommend or refute IVIg in women with RM. IVIg should therefore be assessed in further randomised clinical trials with positive outcomes before any clinical use is considered.
Leivo, Tiina; Sarikkola, Anna-Ulrika; Uusitalo, Risto J; Hellstedt, Timo; Ess, Sirje-Linda; Kivelä, Tero
2011-06-01
To present an economic-analysis comparison of simultaneous and sequential bilateral cataract surgery. Helsinki University Eye Hospital, Helsinki, Finland. Economic analysis. Effects were estimated from data in a study in which patients were randomized to have bilateral cataract surgery on the same day (study group) or sequentially (control group). The main clinical outcomes were corrected distance visual acuity, refraction, complications, Visual Function Index-7 (VF-7) scores, and patient-rated satisfaction with vision. Health-care costs of surgeries and preoperative and postoperative visits were estimated, including the cost of staff, equipment, material, floor space, overhead, and complications. The data were obtained from staff measurements, questionnaires, internal hospital records, and accountancy. Non-health-care costs of travel, home care, and time were estimated based on questionnaires from a random subset of patients. The main economic outcome measures were cost per VF-7 score unit change and cost per patient in simultaneous versus sequential surgery. The study comprised 520 patients (241 patients included non-health-care and time cost analyses). Surgical outcomes and patient satisfaction were similar in both groups. Simultaneous cataract surgery saved 449 Euros (€) per patient in health-care costs and €739 when travel and paid home-care costs were included. The savings added up to €849 per patient when the cost of lost working time was included. Compared with sequential bilateral cataract surgery, simultaneous bilateral cataract surgery provided comparable clinical outcomes with substantial savings in health-care and non-health-care-related costs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Tang, Ning; Zhang, Qianqian; Fang, Shu; Han, Xiao; Wang, Zhehai
2017-01-01
Treatment of non-small-cell lung cancer (NSCLC) with wild-type epidermal growth factor receptor (EGFR) is still a challenge. This study explored antitumor activity of high-dose icotinib (an EGFR tyrosine kinase inhibitor) plus sequential docetaxel against wild-type EGFR NSCLC cells-generated nude mouse xenografts. Nude mice were subcutaneously injected with wild-type EGFR NSCLC A549 cells and divided into different groups for 3-week treatment. Tumor xenograft volumes were monitored and recorded, and at the end of experiments, tumor xenografts were removed for Western blot and immunohistochemical analyses. Compared to control groups (negative control, regular-dose icotinib [IcoR], high-dose icotinib [IcoH], and docetaxel [DTX]) and regular icotinib dose (60 mg/kg) with docetaxel, treatment of mice with a high-dose (1200 mg/kg) of icotinib plus sequential docetaxel for 3 weeks (IcoH-DTX) had an additive effect on suppression of tumor xenograft size and volume (P < 0.05). Icotinib-containing treatments markedly reduced phosphorylation of EGFR, mitogen activated protein kinase (MAPK), and protein kinase B (Akt), but only the high-dose icotinib-containing treatments showed an additive effect on CD34 inhibition (P < 0.05), an indication of reduced microvessel density in tumor xenografts. Moreover, high-dose icotinib plus docetaxel had a similar effect on mouse weight loss (a common way to measure adverse reactions in mice), compared to the other treatment combinations. The study indicate that the high dose of icotinib plus sequential docetaxel (IcoH-DTX) have an additive effect on suppressing the growth of wild-type EGFR NSCLC cell nude mouse xenografts, possibly through microvessel density reduction. Future clinical trials are needed to confirm the findings of this study. PMID:27852073
On the role of verbalization during task set selection: switching or serial order control?
Bryck, Richard L; Mayr, Ulrich
2005-06-01
Recent task-switching work in which paper-and-pencil administered single-task lists were compared with task-alternation lists has demonstrated large increases in task-switch costs with concurrent articulatory suppression (AS), implicating a crucial role for verbalization during switching (Baddeley, Chincotta, & Adlam, 2001; Emerson & Miyake, 2003). Experiment 1 replicated this result, using computerized assessment, albeit with much smaller effect sizes than in the original reports. In Experiment 2, AS interference was reduced when a sequential cue (spatial location) that indicated the current position in the sequence of task alternations was given. Finally, in Experiment 3, switch trials and no-switch trials were compared within a block of alternating runs of two tasks. Again, AS interference was obtained mainly when the endogenous sequencing demand was high, and it was comparable for no-switch and switch trials. These results suggest that verbalization may be critical for endogenous maintenance and updating of a sequential plan, rather than exclusively for the actual switching process.
Ventura Ferreira, Mónica S; Crysandt, Martina; Ziegler, Patrick; Hummel, Sebastian; Wilop, Stefan; Kirschner, Martin; Schemionek, Mirle; Jost, Edgar; Wagner, Wolfgang; Brümmendorf, Tim H; Beier, Fabian
2017-09-01
Telomere shortening represents an established mechanism connecting aging and cancer development. We sequentially analyzed telomere length (TL) of 49 acute myeloid leukemia (AML) patients at diagnosis (n = 24), once they achieved complete cytological remission (CCR) and/or during refractory disease or relapse and after 1-year follow-up, with all patients having at least two sequential samples. TL was analyzed by monochrome multiplex quantitative polymerase chain reaction. We have observed substantially shortened TL in the cells of patients at diagnosis compared to age-adjusted controls. In patients reaching CCR after chemotherapy, telomere shortening was less pronounced than in persistence or relapse but still significantly shortened compared to controls. We estimate patients harboring approximately 20 years of premature telomere loss compared to healthy aged-matched subjects at the time of AML onset. Our data indicate a pre-existing telomere deficit in non-clonal hematopoiesis of AML patients providing a link between age and AML development.
Shen, J Q; Ji, Q; Ding, W J; Xia, L M; Wei, L; Wang, C S
2018-03-13
Objective: To evaluate in-hospital and mid-term outcomes of sequential versus separate grafting of in situ skeletonized left internal mammary artery (LIMA) to the left coronary system in a single-center, propensity-matched study. Methods: After propensity score matching, 120 pairs of patients undergoing first, scheduled, isolated coronary artery bypass grafting (CABG) with in situ skeletonized LIMA grafting to the left anterior descending artery (LAD) territory were entered into a sequential group (sequential grafting of LIMA to the diagonal artery and then to the LAD) or a control group (separate grafting of LIMA to the LAD). The in-hospital and follow-up clinical outcomes and follow-up LIMA graft patency were compared. Results: The two propensity score-matched groups had similar in-hospital and follow-up clinical outcomes. The number of bypass conduits ranged from 3 to 6 (with a mean of 3.5), and 91.3%(219/240)of the included patients received off-pump CABG surgery. No significant differences were found between the two propensity score-matched groups in the in-hospital outcomes, including in-hospital death and the incidence of complications associated with CABG (prolonged ventilation, peroperative stroke, re-operation before discharge, and deep sternal wound infection). During follow-up, 9 patients (4 patients from the sequential group and 5 patients from the control group) died, and the all-cause mortality rate was 3.9%. No significant difference was found in the all-cause mortality rate between the 2 groups[3.4% (4/116) vs 4.3% (5/115), P =0.748]. During follow-up period, 99.1% (115/116) patency for the diagonal site and 98.3% (114/116) for the LAD site were determined by coronary computed tomographic angiography after sequential LIMA grafting, both of which were similar with graft patency of separate grafting of in situ skeletonized LIMA to the LAD. Conclusions: Revascularization of the left coronary system using a skeletonized LIMA resulted in excellent in-hospital and mid-term clinical outcomes and graft patency using sequential grafting.
Colligan, Lacey; Anderson, Janet E; Potts, Henry W W; Berman, Jonathan
2010-01-07
Many quality and safety improvement methods in healthcare rely on a complete and accurate map of the process. Process mapping in healthcare is often achieved using a sequential flow diagram, but there is little guidance available in the literature about the most effective type of process map to use. Moreover there is evidence that the organisation of information in an external representation affects reasoning and decision making. This exploratory study examined whether the type of process map - sequential or hierarchical - affects healthcare practitioners' judgments. A sequential and a hierarchical process map of a community-based anti coagulation clinic were produced based on data obtained from interviews, talk-throughs, attendance at a training session and examination of protocols and policies. Clinic practitioners were asked to specify the parts of the process that they judged to contain quality and safety concerns. The process maps were then shown to them in counter-balanced order and they were asked to circle on the diagrams the parts of the process where they had the greatest quality and safety concerns. A structured interview was then conducted, in which they were asked about various aspects of the diagrams. Quality and safety concerns cited by practitioners differed depending on whether they were or were not looking at a process map, and whether they were looking at a sequential diagram or a hierarchical diagram. More concerns were identified using the hierarchical diagram compared with the sequential diagram and more concerns were identified in relation to clinical work than administrative work. Participants' preference for the sequential or hierarchical diagram depended on the context in which they would be using it. The difficulties of determining the boundaries for the analysis and the granularity required were highlighted. The results indicated that the layout of a process map does influence perceptions of quality and safety problems in a process. In quality improvement work it is important to carefully consider the type of process map to be used and to consider using more than one map to ensure that different aspects of the process are captured.
Multi-channel temperature measurement amplification system. [solar heating systems
NASA Technical Reports Server (NTRS)
Currie, J. R. (Inventor)
1981-01-01
A number of differential outputs of thermocouples are sequentially amplified by a common amplifier. The amplified outputs are compared with a reference temperature signal in an offset correction amplifier, and a particularly poled output signal is provided when a differential output is of a discrete level compared with a reference temperature signal.
Galletly, Cherrie A; Carnell, Benjamin L; Clarke, Patrick; Gill, Shane
2017-03-01
A great deal of research has established the efficacy of repetitive transcranial magnetic stimulation (rTMS) in the treatment of depression. However, questions remain about the optimal method to deliver treatment. One area requiring consideration is the difference in efficacy between bilateral and unilateral treatment protocols. This study aimed to compare the effectiveness of sequential bilateral rTMS and right unilateral rTMS. A total of 135 patients participated in the study, receiving either bilateral rTMS (N = 57) or right unilateral rTMS (N = 78). Treatment response was assessed using the Hamilton depression rating scale. Sequential bilateral rTMS had a higher response rate than right unilateral (43.9% vs 30.8%), but this difference was not statistically significant. This was also the case for remission rates (33.3% vs 21.8%, respectively). Controlling for pretreatment severity of depression, the results did not indicate a significant difference between the protocols with regard to posttreatment Hamilton depression rating scale scores. The current study found no statistically significant differences in response and remission rates between sequential bilateral rTMS and right unilateral rTMS. Given the shorter treatment time and the greater safety and tolerability of right unilateral rTMS, this may be a better choice than bilateral treatment in clinical settings.
NASA Astrophysics Data System (ADS)
Masson, F.; Mouyen, M.; Hwang, C.; Wu, Y.-M.; Ponton, F.; Lehujeur, M.; Dorbath, C.
2012-11-01
Using a Bouguer anomaly map and a dense seismic data set, we have performed two studies in order to improve our knowledge of the deep structure of Taiwan. First, we model the Bouguer anomaly along a profile crossing the island using simple forward modelling. The modelling is 2D, with the hypothesis of cylindrical symmetry. Second we present a joint analysis of gravity anomaly and seismic arrival time data recorded in Taiwan. An initial velocity model has been obtained by local earthquake tomography (LET) of the seismological data. The LET velocity model was used to construct an initial 3D gravity model, using a linear velocity-density relationship (Birch's law). The synthetic Bouguer anomaly calculated for this model has the same shape and wavelength as the observed anomaly. However some characteristics of the anomaly map are not retrieved. To derive a crustal velocity/density model which accounts for both types of observations, we performed a sequential inversion of seismological and gravity data. The variance reduction of the arrival time data for the final sequential model was comparable to the variance reduction obtained by simple LET. Moreover, the sequential model explained about 80% of the observed gravity anomaly. New 3D model of Taiwan lithosphere is presented.
NASA Astrophysics Data System (ADS)
Fishman, M. M.
1985-01-01
The problem of multialternative sequential discernment of processes is formulated in terms of conditionally optimum procedures minimizing the average length of observations, without any probabilistic assumptions about any one occurring process, rather than in terms of Bayes procedures minimizing the average risk. The problem is to find the procedure that will transform inequalities into equalities. The problem is formulated for various models of signal observation and data processing: (1) discernment of signals from background interference by a multichannel system; (2) discernment of pulse sequences with unknown time delay; (3) discernment of harmonic signals with unknown frequency. An asymptotically optimum sequential procedure is constructed which compares the statistics of the likelihood ratio with the mean-weighted likelihood ratio and estimates the upper bound for conditional average lengths of observations. This procedure is shown to remain valid as the upper bound for the probability of erroneous partial solutions decreases approaching zero and the number of hypotheses increases approaching infinity. It also remains valid under certain special constraints on the probability such as a threshold. A comparison with a fixed-length procedure reveals that this sequential procedure decreases the length of observations to one quarter, on the average, when the probability of erroneous partial solutions is low.
Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods
NASA Technical Reports Server (NTRS)
Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.
1991-01-01
The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.
Liu, Rong
2017-01-01
Obtaining a fast and reliable decision is an important issue in brain-computer interfaces (BCI), particularly in practical real-time applications such as wheelchair or neuroprosthetic control. In this study, the EEG signals were firstly analyzed with a power projective base method. Then we were applied a decision-making model, the sequential probability ratio testing (SPRT), for single-trial classification of motor imagery movement events. The unique strength of this proposed classification method lies in its accumulative process, which increases the discriminative power as more and more evidence is observed over time. The properties of the method were illustrated on thirteen subjects' recordings from three datasets. Results showed that our proposed power projective method outperformed two benchmark methods for every subject. Moreover, with sequential classifier, the accuracies across subjects were significantly higher than that with nonsequential ones. The average maximum accuracy of the SPRT method was 84.1%, as compared with 82.3% accuracy for the sequential Bayesian (SB) method. The proposed SPRT method provides an explicit relationship between stopping time, thresholds, and error, which is important for balancing the time-accuracy trade-off. These results suggest SPRT would be useful in speeding up decision-making while trading off errors in BCI. PMID:29348781
Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods
NASA Astrophysics Data System (ADS)
Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.
1991-10-01
The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.
Filter methods to preserve local contrast and to avoid artifacts in gamut mapping
NASA Astrophysics Data System (ADS)
Meili, Marcel; Küpper, Dennis; Barańczuk, Zofia; Caluori, Ursina; Simon, Klaus
2010-01-01
Contrary to high dynamic range imaging, the preservation of details and the avoidance of artifacts is not explicitly considered in popular color management systems. An effective way to overcome these difficulties is image filtering. In this paper we investigate several image filter concepts for detail preservation as part of a practical gamut mapping strategy. In particular we define four concepts including various image filters and check their performance with a psycho-visual test. Additionally, we compare our performance evaluation to two image quality measures with emphasis on local contrast. Surprisingly, the most simple filter concept performs highly efficient and achieves an image quality which is comparable to the more established but slower methods.
Comparing Ancient DNA Preservation in Petrous Bone and Tooth Cementum
Margaryan, Ashot; Stenderup, Jesper; Lynnerup, Niels; Willerslev, Eske; Allentoft, Morten E.
2017-01-01
Large-scale genomic analyses of ancient human populations have become feasible partly due to refined sampling methods. The inner part of petrous bones and the cementum layer in teeth roots are currently recognized as the best substrates for such research. We present a comparative analysis of DNA preservation in these two substrates obtained from the same human skulls, across a range of different ages and preservation environments. Both substrates display significantly higher endogenous DNA content (average of 16.4% and 40.0% for teeth and petrous bones, respectively) than parietal skull bone (average of 2.2%). Despite sample-to-sample variation, petrous bone overall performs better than tooth cementum (p = 0.001). This difference, however, is driven largely by a cluster of viking skeletons from one particular locality, showing relatively poor molecular tooth preservation (<10% endogenous DNA). In the remaining skeletons there is no systematic difference between the two substrates. A crude preservation (good/bad) applied to each sample prior to DNA-extraction predicted the above/below 10% endogenous DNA threshold in 80% of the cases. Interestingly, we observe signficantly higher levels of cytosine to thymine deamination damage and lower proportions of mitochondrial/nuclear DNA in petrous bone compared to tooth cementum. Lastly, we show that petrous bones from ancient cremated individuals contain no measurable levels of authentic human DNA. Based on these findings we discuss the pros and cons of sampling the different elements. PMID:28129388
Is it me? Verbal self-monitoring neural network and clinical insight in schizophrenia.
Sapara, Adegboyega; Ffytche, Dominic H; Cooke, Michael A; Williams, Steven C R; Kumari, Veena
2015-12-30
Self-monitoring, defined as the ability to distinguish between self-generated stimuli from other-generated ones, is known to be impaired in schizophrenia. This impairment has been theorised as the basis for many of the core psychotic symptoms, in particular, poor clinical insight. This study aimed to investigate verbal self-monitoring related neural substrates of preserved and poor clinical insight in schizophrenia. It involved 40 stable schizophrenia outpatients, 20 with preserved and 20 with poor insight, and 20 healthy participants. All participants underwent functional magnetic resonance imaging with brain coverage covering key areas in the self-monitoring network during a verbal self-monitoring task. Healthy participants showed higher performance accuracy and greater thalamic activity than both preserved and poor insight patient groups. Preserved insight patients showed higher activity in the putamen extending into the caudate, insula and inferior frontal gyrus, compared to poor insight patients, and in the anterior cingulate and medial frontal gyrus, compared to healthy participants. Poor insight patients did not show greater activity in any brain area compared to preserved insight patients or healthy participants. Future studies may pursue therapeutic avenues, such as meta-cognitive therapies to promote self-monitoring or targeted stimulation of relevant brain areas, as means of enhancing insight in schizophrenia. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Sequential quantum secret sharing in a noisy environment aided with weak measurements
NASA Astrophysics Data System (ADS)
Ray, Maharshi; Chatterjee, Sourav; Chakrabarty, Indranil
2016-05-01
In this work we give a (n,n)-threshold protocol for sequential secret sharing of quantum information for the first time. By sequential secret sharing we refer to a situation where the dealer is not having all the secrets at the same time, at the beginning of the protocol; however if the dealer wishes to share secrets at subsequent phases she/he can realize it with the help of our protocol. First of all we present our protocol for three parties and later we generalize it for the situation where we have more (n> 3) parties. Interestingly, we show that our protocol of sequential secret sharing requires less amount of quantum as well as classical resource as compared to the situation wherein existing protocols are repeatedly used. Further in a much more realistic situation, we consider the sharing of qubits through two kinds of noisy channels, namely the phase damping channel (PDC) and the amplitude damping channel (ADC). When we carry out the sequential secret sharing in the presence of noise we observe that the fidelity of secret sharing at the kth iteration is independent of the effect of noise at the (k - 1)th iteration. In case of ADC we have seen that the average fidelity of secret sharing drops down to ½ which is equivalent to a random guess of the quantum secret. Interestingly, we find that by applying weak measurements one can enhance the average fidelity. This increase of the average fidelity can be achieved with certain trade off with the success probability of the weak measurements.
Karp, J E; Humphrey, R L; Burke, P J
1981-03-01
Malignant plasma cell proliferation and induced humoral stimulatory activity (HSA) occur in vivo at a predictable time following drug administration. Sequential sera from 11 patients with poor-risk multiple myeloma (MM) undergoing treatment with Cytoxan (CY) 2400 mq/sq m were assayed for their in vitro effects on malignant bone marrow plasma cell tritiated thymidine (3HTdR) incorporation. Peak HSA was detected day 9 following CY. Sequential changes in marrow malignant plasma cell 3HTdR-labeling indices (LI) paralleled changes in serum activity, with peak LI occurring at the time of peak HS. An in vitro model of chemotherapy demonstrated that malignant plasma cell proliferation was enhanced by HSA, as determined by 3HTdR incorporation assay, 3HTdR LI, and tumor cells counts, and that stimulated plasma cells were more sensitive to cytotoxic effects of adriamycin (ADR) than were cells cultured in autologous pretreatment serum. Based on these studies, we designed a clinical trial to treat 12 CY-refractory poor-risk patients with MM in which ADR (60 mg/sq m) was administered at the time of peak HSA and residual tumor cell LI (day 9) following initial CY, 2400 mg/m (CY1ADR9). Eight of 12 (67%) responded to timed sequential chemotherapy with a greater than 50% decrement in monoclonal protein marker and a median survival projected to be greater than 8 mo duration (range 4-21+ mo). These clinical results using timed sequential CY1ADR9 compare favorably with results obtained using ADR in nonsequential chemotherapeutic regimens.
Efficient sequential and parallel algorithms for record linkage
Mamun, Abdullah-Al; Mi, Tian; Aseltine, Robert; Rajasekaran, Sanguthevar
2014-01-01
Background and objective Integrating data from multiple sources is a crucial and challenging problem. Even though there exist numerous algorithms for record linkage or deduplication, they suffer from either large time needs or restrictions on the number of datasets that they can integrate. In this paper we report efficient sequential and parallel algorithms for record linkage which handle any number of datasets and outperform previous algorithms. Methods Our algorithms employ hierarchical clustering algorithms as the basis. A key idea that we use is radix sorting on certain attributes to eliminate identical records before any further processing. Another novel idea is to form a graph that links similar records and find the connected components. Results Our sequential and parallel algorithms have been tested on a real dataset of 1 083 878 records and synthetic datasets ranging in size from 50 000 to 9 000 000 records. Our sequential algorithm runs at least two times faster, for any dataset, than the previous best-known algorithm, the two-phase algorithm using faster computation of the edit distance (TPA (FCED)). The speedups obtained by our parallel algorithm are almost linear. For example, we get a speedup of 7.5 with 8 cores (residing in a single node), 14.1 with 16 cores (residing in two nodes), and 26.4 with 32 cores (residing in four nodes). Conclusions We have compared the performance of our sequential algorithm with TPA (FCED) and found that our algorithm outperforms the previous one. The accuracy is the same as that of this previous best-known algorithm. PMID:24154837
Lu, Sharon M; Chang-Halpenny, Christine; Hwang-Graziano, Julie
2015-04-01
To compare the efficacy and tolerance of adjuvant chemotherapy and radiotherapy delivered in sequential (chemotherapy followed by radiation) versus "sandwich" fashion (chemotherapy, interval radiation, and remaining chemotherapy) after surgery in patients with FIGO stage III uterine endometrioid adenocarcinoma. From 2004 to 2011, we identified 51 patients treated at our institution fitting the above criteria. All patients received surgical staging followed by adjuvant chemoradiation (external-beam radiation therapy (EBRT) with or without high-dose rate (HDR) vaginal brachytherapy (VB)). Of these, 73% and 27% of patients received their adjuvant therapy in sequential and sandwich fashion, respectively. There were no significant differences in clinical or pathologic factors between patients treated with either regimen. Thirty-nine (76%) patients had stage IIIC disease. The majority of patients received 6 cycles of paclitaxel with carboplatin or cisplatin. Median EBRT dose was 45 Gy and 54% of patients received HDR VB boost (median dose 21 Gy). There were no significant differences in the estimated 5-year overall survival, local progression-free survival, and distant metastasis-free survival between the sequential and sandwich groups: 87% vs. 77% (p=0.37), 89% vs. 100% (p=0.21), and 78% vs. 85% (p=0.79), respectively. No grade 3-4 genitourinary or gastrointestinal toxicities were reported in either group. There was a trend towards higher incidence of grade 3-4 hematologic toxicity in the sandwich group. Adjuvant chemoradiation for FIGO stage III endometrioid uterine cancer given in either sequential or sandwich fashion appears to offer equally excellent early clinical outcomes and acceptably low toxicity. Copyright © 2015 Elsevier Inc. All rights reserved.
Cui, Haiying; Bai, Mei; Yuan, Lu; Surendhiran, Duraiarasan; Lin, Lin
2018-03-02
Escherichia coli O157:H7 (E. coli O157:H7) is one of the most common pathogens in fresh vegetables and fruits, and most of the diseases produced by E. coli O157:H7 are associated with biofilms. Cold nitrogen plasma (CNP) is a cold sterilization technique which has no residue. However to completely eliminate the biofilm on the surface of vegetables the processing power and time of CNP have to be enhanced, which will impact on the quality of fruits and vegetables. Thus the sequential treatment of CNP and phage techniques was engineered in this study. Compared to treatment performed separately, sequential treatment not only had more mild treatment conditions as 400W CNP treatment for 2min and 5% phage treatment for 30min, but also exhibited more remarkable effect on eradicating E. coli O157:H7 biofilms in vitro and on vegetables. The population of E. coli O157:H7 was approximately reduced by 2logCFU/cm 2 after individual treatment of 5% phages for 30min or 500W CNP for 3min. While the sequential treatment of CNP (400W, 2min) and phages (5%, 30min) reduced the E. coli O157:H7 viable count in biofilm by 5.71logCFU/cm 2 . Therefore, the sequential treatment holds a great promise to improve the current treatment systems of bacterial contamination on different vegetable surfaces. Copyright © 2018 Elsevier B.V. All rights reserved.
Yoda, Satoshi; Lin, Jessica J; Lawrence, Michael S; Burke, Benjamin J; Friboulet, Luc; Langenbucher, Adam; Dardaei, Leila; Prutisto-Chang, Kylie; Dagogo-Jack, Ibiayi; Timofeevski, Sergei; Hubbeling, Harper; Gainor, Justin F; Ferris, Lorin A; Riley, Amanda K; Kattermann, Krystina E; Timonina, Daria; Heist, Rebecca S; Iafrate, A John; Benes, Cyril H; Lennerz, Jochen K; Mino-Kenudson, Mari; Engelman, Jeffrey A; Johnson, Ted W; Hata, Aaron N; Shaw, Alice T
2018-06-01
The cornerstone of treatment for advanced ALK-positive lung cancer is sequential therapy with increasingly potent and selective ALK inhibitors. The third-generation ALK inhibitor lorlatinib has demonstrated clinical activity in patients who failed previous ALK inhibitors. To define the spectrum of ALK mutations that confer lorlatinib resistance, we performed accelerated mutagenesis screening of Ba/F3 cells expressing EML4-ALK. Under comparable conditions, N -ethyl- N -nitrosourea (ENU) mutagenesis generated numerous crizotinib-resistant but no lorlatinib-resistant clones harboring single ALK mutations. In similar screens with EML4-ALK containing single ALK resistance mutations, numerous lorlatinib-resistant clones emerged harboring compound ALK mutations. To determine the clinical relevance of these mutations, we analyzed repeat biopsies from lorlatinib-resistant patients. Seven of 20 samples (35%) harbored compound ALK mutations, including two identified in the ENU screen. Whole-exome sequencing in three cases confirmed the stepwise accumulation of ALK mutations during sequential treatment. These results suggest that sequential ALK inhibitors can foster the emergence of compound ALK mutations, identification of which is critical to informing drug design and developing effective therapeutic strategies. Significance: Treatment with sequential first-, second-, and third-generation ALK inhibitors can select for compound ALK mutations that confer high-level resistance to ALK-targeted therapies. A more efficacious long-term strategy may be up-front treatment with a third-generation ALK inhibitor to prevent the emergence of on-target resistance. Cancer Discov; 8(6); 714-29. ©2018 AACR. This article is highlighted in the In This Issue feature, p. 663 . ©2018 American Association for Cancer Research.
Pamnani, Shitaldas J.; Nyitray, Alan G.; Abrahamsen, Martha; Rollison, Dana E.; Villa, Luisa L.; Lazcano-Ponce, Eduardo; Huang, Yangxin; Borenstein, Amy; Giuliano, Anna R.
2016-01-01
Background. The purpose of this study was to assess the risk of sequential acquisition of anal human papillomavirus (HPV) infection following a type-specific genital HPV infection for the 9-valent vaccine HPV types and investigate factors associated with sequential infection among men who have sex with women (MSW). Methods. Genital and anal specimens were available for 1348 MSW participants, and HPV genotypes were detected using the Roche Linear Array assay. Sequential risk of anal HPV infection was assessed using hazard ratios (HRs) among men with prior genital infection, compared with men with no prior genital infection, in individual HPV type and grouped HPV analyses. Results. In individual analyses, men with prior HPV 16 genital infections had a significantly higher risk of subsequent anal HPV 16 infections (HR, 4.63; 95% confidence interval [CI], 1.41–15.23). In grouped analyses, a significantly higher risk of sequential type-specific anal HPV infections was observed for any of the 9 types (adjusted HR, 2.80; 95% CI, 1.32–5.99), high-risk types (adjusted HR, 2.65; 95% CI, 1.26, 5.55), and low-risk types (adjusted HR, 5.89; 95% CI, 1.29, 27.01). Conclusions. MSW with prior genital HPV infections had a higher risk of a subsequent type-specific anal infection. The higher risk was not explained by sexual intercourse with female partners. Autoinoculation is a possible mechanism for the observed association. PMID:27489298
Lee, Tae Hoon; Hwang, Soon Oh; Choi, Hyun Jong; Jung, Yunho; Cha, Sang Woo; Chung, Il-Kwun; Moon, Jong Ho; Cho, Young Deok; Park, Sang-Heum; Kim, Sun-Joo
2014-02-17
Numerous clinical trials to improve the success rate of biliary access in difficult biliary cannulation (DBC) during ERCP have been reported. However, standard guidelines or sequential protocol analysis according to different methods are limited in place. We planned to investigate a sequential protocol to facilitate selective biliary access for DBC during ERCP. This prospective clinical study enrolled 711 patients with naïve papillae at a tertiary referral center. If wire-guided cannulation was deemed to have failed due to the DBC criteria, then according to the cannulation algorithm early precut fistulotomy (EPF; cannulation time > 5 min, papillary contacts > 5 times, or hook-nose-shaped papilla), double-guidewire cannulation (DGC; unintentional pancreatic duct cannulation ≥ 3 times), and precut after placement of a pancreatic stent (PPS; if DGC was difficult or failed) were performed sequentially. The main outcome measurements were the technical success, procedure outcomes, and complications. Initially, a total of 140 (19.7%) patients with DBC underwent EPF (n = 71) and DGC (n = 69). Then, in DGC group 36 patients switched to PPS due to difficulty criteria. The successful biliary cannulation rate was 97.1% (136/140; 94.4% [67/71] with EPF, 47.8% [33/69] with DGC, and 100% [36/36] with PPS; P < 0.001). The mean successful cannulation time (standard deviation) was 559.4 (412.8) seconds in EPF, 314.8 (65.2) seconds in DGC, and 706.0 (469.4) seconds in PPS (P < 0.05). The DGC group had a relatively low successful cannulation rate (47.8%) but had a shorter cannulation time compared to the other groups due to early switching to the PPS method in difficult or failed DGC. Post-ERCP pancreatitis developed in 14 (10%) patients (9 mild, 1 moderate), which did not differ significantly among the groups (P = 0.870) or compared with the conventional group (P = 0.125). Based on the sequential protocol analysis, EPF, DGC, and PPS may be safe and feasible for DBC. The use of EPF in selected DBC criteria, DGC in unintentional pancreatic duct cannulations, and PPS in failed or difficult DGC may facilitate successful biliary cannulation.
Next-gen tissue: preservation of molecular and morphological fidelity in prostate tissue.
Gillard, Marc; Tom, Westin R; Antic, Tatjana; Paner, Gladell P; Lingen, Mark W; VanderWeele, David J
2015-01-01
Personalization of cancer therapy requires molecular evaluation of tumor tissue. Traditional tissue preservation involves formalin fixation, which degrades the quality of nucleic acids. Strategies to bank frozen prostate tissue can interfere with diagnostic studies. PAXgene is an alternative fixative that preserves protein and nucleic acid quality. Portions of prostates obtained from autopsy specimens were fixed in either 10% buffered formalin or PAXgene, and processed and embedded in paraffin. Additional sections were immediately embedded in OCT and frozen. DNA and RNA were extracted from the formalin-fixed, PAXgene-fixed, or frozen tissue. Quantitative PCR was used to compare the quality of DNA and RNA obtained from all three tissue types. In addition, 5 μm sections were cut from specimens devoid of cancer and from prostate cancer specimens obtained at prostatectomy and fixed in PAXgene. They were either stained with hematoxylin and eosin or interrogated with antibodies for p63, PSA and p504. Comparable tissue morphology was observed in both the formalin and PAXgene-fixed specimens. Similarly, immunohistochemical expression of the P63, PSA and P504 proteins was comparable between formalin and PAXgene fixation techniques. DNA from the PAXgene-fixed tissue was of similar quality to that from frozen tissue. RNA was also amplified with up to 8-fold greater efficiency in the PAXgene fixed tissue compared to the formalin-fixed tissue. Prostate specimens fixed with PAXgene have preserved histologic morphology, stain appropriately, and have preserved quality of nucleic acids. PAXgene fixation facilitates the use of prostatectomy tissue for molecular biology techniques such as next-generation sequencing.
Hydrogen Supplementation of Preservation Solution Improves Viability of Osteochondral Grafts
Yamada, Takuya; Onuma, Kenji; Kuzuno, Jun; Ujihira, Masanobu; Kurokawa, Ryosuke; Sakai, Rina; Takaso, Masashi
2014-01-01
Allogenic osteochondral tissue (OCT) is used for the treatment of large cartilage defects. Typically, OCTs collected during the disease-screening period are preserved at 4°C; however, the gradual reduction in cell viability during cold preservation adversely affects transplantation outcomes. Therefore, improved storage methods that maintain the cell viability of OCTs are needed to increase the availability of high-quality OCTs and improve treatment outcomes. Here, we evaluated whether long-term hydrogen delivery to preservation solution improved the viability of rat OCTs during cold preservation. Hydrogen-supplemented Dulbecco's Modified Eagles Medium (DMEM) and University of Wisconsin (UW) solution both significantly improved the cell viability of OCTs during preservation at 4°C for 21 days compared to nonsupplemented media. However, the long-term cold preservation of OCTs in DMEM containing hydrogen was associated with the most optimal maintenance of chondrocytes with respect to viability and morphology. Our findings demonstrate that OCTs preserved in DMEM supplemented with hydrogen are a promising material for the repair of large cartilage defects in the clinical setting. PMID:25506061
Design and testing of safer more effective preservatives for consumer products
USDA-ARS?s Scientific Manuscript database
A comprehensive evaluation of both safety and efficacy of alternative preservatives is crucial to the development of more sustainable composite materials, formulated products, and food packaging. By comparing the antimicrobial activity against Aspergillus brasiliensis (mold) and Pseudomonas aerugino...
Preservation and phylogeny of Cambrian ecdysozoans tested by experimental decay of Priapulus
NASA Astrophysics Data System (ADS)
Sansom, Robert S.
2016-09-01
The exceptionally preserved Cambrian fossil record provides unique insight into the early evolutionary history of animals. Understanding of the mechanisms of exceptional soft tissue preservation frames all interpretations of the fauna and its evolutionary significance. This is especially true for recent interpretations of preserved nervous tissues in fossil ecdysozoans. However, models of soft tissue preservation lack empirical support from actualistic studies. Here experimental decay of the priapulid Priapulus reveal consistent bias towards rapid loss of internal non-cuticular anatomy compared with recalcitrant cuticular anatomy. This is consistent with models of Burgess Shale-type preservation and indicates that internal tissues are unlikely to be preserved with fidelity if organically preserved. This pattern, along with extreme body margin distortion, is consistent with onychophoran decay, and is therefore resolved as general for early ecdysozoans. Application of these patterns to phylogenetic data finds scalidophoran taxa to be very sensitive to taphonomically informed character coding, but not panarthropodan taxa. Priapulid decay also have unexpected relevance for interpretation of myomeres in fossil chordates. The decay data presented serve not only as a test of models of preservation but also a framework with which to interpret ecdysozoan fossil anatomies, and the subsequent evolutionary inferences drawn from them.
Preservation and phylogeny of Cambrian ecdysozoans tested by experimental decay of Priapulus
Sansom, Robert S.
2016-01-01
The exceptionally preserved Cambrian fossil record provides unique insight into the early evolutionary history of animals. Understanding of the mechanisms of exceptional soft tissue preservation frames all interpretations of the fauna and its evolutionary significance. This is especially true for recent interpretations of preserved nervous tissues in fossil ecdysozoans. However, models of soft tissue preservation lack empirical support from actualistic studies. Here experimental decay of the priapulid Priapulus reveal consistent bias towards rapid loss of internal non-cuticular anatomy compared with recalcitrant cuticular anatomy. This is consistent with models of Burgess Shale-type preservation and indicates that internal tissues are unlikely to be preserved with fidelity if organically preserved. This pattern, along with extreme body margin distortion, is consistent with onychophoran decay, and is therefore resolved as general for early ecdysozoans. Application of these patterns to phylogenetic data finds scalidophoran taxa to be very sensitive to taphonomically informed character coding, but not panarthropodan taxa. Priapulid decay also have unexpected relevance for interpretation of myomeres in fossil chordates. The decay data presented serve not only as a test of models of preservation but also a framework with which to interpret ecdysozoan fossil anatomies, and the subsequent evolutionary inferences drawn from them. PMID:27595908
Sequential single shot X-ray photon correlation spectroscopy at the SACLA free electron laser
Lehmkühler, Felix; Kwaśniewski, Paweł; Roseker, Wojciech; ...
2015-11-27
In this study, hard X-ray free electron lasers allow for the first time to access dynamics of condensed matter samples ranging from femtoseconds to several hundred seconds. In particular, the exceptional large transverse coherence of the X-ray pulses and the high time-averaged flux promises to reach time and length scales that have not been accessible up to now with storage ring based sources. However, due to the fluctuations originating from the stochastic nature of the self-amplified spontaneous emission (SASE) process the application of well established techniques such as X-ray photon correlation spectroscopy (XPCS) is challenging. Here we demonstrate a single-shotmore » based sequential XPCS study on a colloidal suspension with a relaxation time comparable to the SACLA free-electron laser pulse repetition rate. High quality correlation functions could be extracted without any indications for sample damage. This opens the way for systematic sequential XPCS experiments at FEL sources.« less
Sequential single shot X-ray photon correlation spectroscopy at the SACLA free electron laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lehmkühler, Felix; Kwaśniewski, Paweł; Roseker, Wojciech
In this study, hard X-ray free electron lasers allow for the first time to access dynamics of condensed matter samples ranging from femtoseconds to several hundred seconds. In particular, the exceptional large transverse coherence of the X-ray pulses and the high time-averaged flux promises to reach time and length scales that have not been accessible up to now with storage ring based sources. However, due to the fluctuations originating from the stochastic nature of the self-amplified spontaneous emission (SASE) process the application of well established techniques such as X-ray photon correlation spectroscopy (XPCS) is challenging. Here we demonstrate a single-shotmore » based sequential XPCS study on a colloidal suspension with a relaxation time comparable to the SACLA free-electron laser pulse repetition rate. High quality correlation functions could be extracted without any indications for sample damage. This opens the way for systematic sequential XPCS experiments at FEL sources.« less
[Sequential monitoring of renal transplant with aspiration cytology].
Manfro, R C; Gonçalves, L F; de Moura, L A
1998-01-01
To evaluate the utility of kidney aspiration cytology in the sequential monitorization of acute rejection in renal transplant patients. Thirty patients were submitted to 376 aspirations. The clinical diagnoses were independently established. The representativity of the samples reached 82.7%. The total corrected increment index and the number of immunoactivated cells were higher during acute rejection as compared to normal allograft function, acute tubular necrosis, and cyclosporine nephrotoxicity. The parameters to the diagnosis of acute rejection were sensitivity: 71.8%, specificity: 87.3%, positive predictive value: 50.9%, negative predictive value: 94.9% and accuracy 84.9%. The false positive results were mainly related to cytomegalovirus infection or to the administration of OKT3. In 10 out of 11 false negative results incipient immunoactivation was present alerting to the possibility of acute rejection. Kidney aspiration cytology is a useful tool for the sequential monitorization of acute rejection in renal transplant patients. The best results are reached when the results of aspiration cytology are analyzed with the clinical data.
NASA Technical Reports Server (NTRS)
Braun, W. R.
1981-01-01
Pseudo noise (PN) spread spectrum systems require a very accurate alignment between the PN code epochs at the transmitter and receiver. This synchronism is typically established through a two-step algorithm, including a coarse synchronization procedure and a fine synchronization procedure. A standard approach for the coarse synchronization is a sequential search over all code phases. The measurement of the power in the filtered signal is used to either accept or reject the code phase under test as the phase of the received PN code. This acquisition strategy, called a single dwell-time system, has been analyzed by Holmes and Chen (1977). A synopsis of the field of sequential analysis as it applies to the PN acquisition problem is provided. From this, the implementation of the variable dwell time algorithm as a sequential probability ratio test is developed. The performance of this algorithm is compared to the optimum detection algorithm and to the fixed dwell-time system.
Parallelization of NAS Benchmarks for Shared Memory Multiprocessors
NASA Technical Reports Server (NTRS)
Waheed, Abdul; Yan, Jerry C.; Saini, Subhash (Technical Monitor)
1998-01-01
This paper presents our experiences of parallelizing the sequential implementation of NAS benchmarks using compiler directives on SGI Origin2000 distributed shared memory (DSM) system. Porting existing applications to new high performance parallel and distributed computing platforms is a challenging task. Ideally, a user develops a sequential version of the application, leaving the task of porting to new generations of high performance computing systems to parallelization tools and compilers. Due to the simplicity of programming shared-memory multiprocessors, compiler developers have provided various facilities to allow the users to exploit parallelism. Native compilers on SGI Origin2000 support multiprocessing directives to allow users to exploit loop-level parallelism in their programs. Additionally, supporting tools can accomplish this process automatically and present the results of parallelization to the users. We experimented with these compiler directives and supporting tools by parallelizing sequential implementation of NAS benchmarks. Results reported in this paper indicate that with minimal effort, the performance gain is comparable with the hand-parallelized, carefully optimized, message-passing implementations of the same benchmarks.
NASA Technical Reports Server (NTRS)
Wightman, J. M.
1973-01-01
Sequential band-6 imagery of the Zambesi Basin of southern Africa recorded substantial changes in burn patterns resulting from late dry season grass fires. One example from northern Botswana, indicates that a fire consumed approximately 70 square miles of grassland over a 24-hour period. Another example from western Zambia indicates increased fire activity over a 19-day period. Other examples clearly define the area of widespread grass fires in Angola, Botswana, Rhodesia and Zambia. From the fire patterns visible on the sequential portions of the imagery, and the time intervals involved, the rates of spread of the fires are estimated and compared with estimates derived from experimental burning plots in Zambia and Canada. It is concluded that sequential ERTS-1 imagery, of the quality studied, clearly provides the information needed to detect and map grass fires and to monitor their rates of spread in this region during the late dry season.
Effects of musical training on sound pattern processing in high-school students.
Wang, Wenjung; Staffaroni, Laura; Reid, Errold; Steinschneider, Mitchell; Sussman, Elyse
2009-05-01
Recognizing melody in music involves detection of both the pitch intervals and the silence between sequentially presented sounds. This study tested the hypothesis that active musical training in adolescents facilitates the ability to passively detect sequential sound patterns compared to musically non-trained age-matched peers. Twenty adolescents, aged 15-18 years, were divided into groups according to their musical training and current experience. A fixed order tone pattern was presented at various stimulus rates while electroencephalogram was recorded. The influence of musical training on passive auditory processing of the sound patterns was assessed using components of event-related brain potentials (ERPs). The mismatch negativity (MMN) ERP component was elicited in different stimulus onset asynchrony (SOA) conditions in non-musicians than musicians, indicating that musically active adolescents were able to detect sound patterns across longer time intervals than age-matched peers. Musical training facilitates detection of auditory patterns, allowing the ability to automatically recognize sequential sound patterns over longer time periods than non-musical counterparts.
Practice-induced and sequential modulations of the Simon effect.
Soetens, Eric; Maetens, Kathleen; Zeischka, Peter
2010-05-01
People react more quickly and more accurately to stimuli presented in locations corresponding to the response, as compared with noncorresponding locations, even when stimulus location is irrelevant (Simon effect [SE]). The explanation that SEs are caused by the automatic priming of a corresponding response has been questioned, because of the many exceptions to the effect. We replicated practice-induced and sequential modulations of the SE in two experiments--first, by training participants with blocks of location-relevant stimuli, and second, by mixing location-relevant and location-irrelevant trials. The decrease of the SE with incompatible training was relatively permanent in the blocked experiment, whereas the effect was temporary in the mixed experiment. The difference was caused by a more permanent reversal of the SE after incongruent trials, showing that sequential modulations depend on long-term practice effects. We suggest that there is a formation of a contralateral long-term memory stimulus-response link in blocked conditions and that short-term and long-term memory links are primed by preceding events.
Novel 2D Triple-Resonance NMR Experiments for Sequential Resonance Assignments of Proteins
NASA Astrophysics Data System (ADS)
Ding, Keyang; Gronenborn, Angela M.
2002-06-01
We present 2D versions of the popular triple resonance HN(CO) CACB, HN(COCA)CACB, HN(CO)CAHA, and HN(COCA) CAHA experiments, commonly used for sequential resonance assignments of proteins. These experiments provide information about correlations between amino proton and nitrogen chemical shifts and the α- and β-carbon and α-proton chemical shifts within and between amino acid residues. Using these 2D spectra, sequential resonance assignments of H N, N, C α, C β, and H α nuclei are easily achieved. The resolution of these spectra is identical to the well-resolved 2D 15N- 1H HSQC and H(NCO)CA spectra, with slightly reduced sensitivity compared to their 3D and 4D versions. These types of spectra are ideally suited for exploitation in automated assignment procedures and thereby constitute a fast and efficient means for NMR structural determination of small and medium-sized proteins in solution in structural genomics programs.
Kvach, Yuriy; Ondračková, Markéta; Janáč, Michal; Jurajda, Pavel
2018-03-05
The aim of this study was to evaluate the influence of preservation method on the results of parasite community studies. Two host species, European perch Perca fluviatilis and European bitterling Rhodeus amarus, were examined for parasites after having been subjected to 4 different storage treatments: freezing, preservation in 4% formaldehyde or 70% ethanol and transportation of live (fresh) fish as a control. Preservation prior to dissection resulted in a loss of information, leading to incomplete quantitative data (all preservation treatments), qualitative data (ethanol and formaldehyde preservation) and a lowered ability to determine parasites to species level based on morphology compared to dissecting fresh fish. Of the more abundant taxa, only crustaceans and acanthocephalans provided relatively even results between treatments. We conclude that preservation media, such as ethanol or formaldehyde, significantly affects the ability to obtain precise parasite community data; hence, we recommend the use of freshly sacrificed fish for parasite community studies whenever possible. Alternatively, freezing may prove acceptable for evaluating parasite community taxonomic composition.
Frezzotti, Paolo; Fogagnolo, Paolo; Haka, Gentiana; Motolese, Ilaria; Iester, Michele; Bagaglia, Simone A; Mittica, Pietro; Menicacci, Cristina; Rossetti, Luca; Motolese, Eduardo
2014-03-01
To evaluate the effects at 1 year of preservative-free timolol gel and preserved timolol eye drops on conjunctiva and tear parameters. Forty patients with primary open-angle glaucoma or ocular hypertension were randomized to the two treatment groups and compared with 20 healthy age-matched controls. Clinical tests (IOP, Schirmer I test, and lacrimal film break-up time BUT) and in vivo conjunctival confocal microscopy (IVCM) were performed in all patients at baseline and after 12 months. IVCM (HRT II Rostock Cornea Module; Heidelberg Engineering GmbH, Heidelberg, Germany) was performed after topical anaesthesia in the four cardinal locations and at the corresponding limbus to analyse conjunctiva cells. The main IVCM outcomes were goblet cell density and epithelial regularity. IVCM and clinical parameters were similar in the three groups at baseline. After 12 months, intra-epithelial goblet cell density was significantly lower in the preserved (48.25 ± 7.70) than in the preservative-free beta-blocker group (86.83 ± 22.17, p < 0.001) and controls (88.9 ± 18.33, p < 0.001). The epithelial layer was significantly more regular in the preserved beta-blocker medication group than in the preservative-free beta-blocker group (p < 0.001) and the control group (p < 0.001). A significant reduction in both Schirmer I and BUT was found in the group of preserved timolol (respectively, 11.3 ± 2.97 and 8.12 ± 0.99) compared with preservative-free timolol (16.8 ± 1.83 and 11.27 ± 1.27, p < 0.001) and controls (17.8 ± 1.87 and 12.10 ± 1.28, p < 0.001). Based on our IVCM data, preservative-free beta-blocker gel induces less changes at ocular surface than preserved beta-blockers, a fact that should be considered to obtain less adverse effects and maximal adherence to treatment in a chronic condition such as glaucoma. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Cochlear Implant Electrode Array From Partial to Full Insertion in Non-Human Primate Model.
Manrique-Huarte, Raquel; Calavia, Diego; Gallego, Maria Antonia; Manrique, Manuel
2018-04-01
To determine the feasibility of progressive insertion (two sequential surgeries: partial to full insertion) of an electrode array and to compare functional outcomes. 8 normal-hearing animals (Macaca fascicularis (MF)) were included. A 14 contact electrode array, which is suitably sized for the MF cochlea was partially inserted (PI) in 16 ears. After 3 months of follow-up revision surgery the electrode was advanced to a full insertion (FI) in 8 ears. Radiological examination and auditory testing was performed monthly for 6 months. In order to compare the values a two way repeated measures ANOVA was used. A p-value below 0.05 was considered as statistically significant. IBM SPSS Statistics V20 was used. Surgical procedure was completed in all cases with no complications. Mean auditory threshold shift (ABR click tones) after 6 months follow-up is 19 dB and 27 dB for PI and FI group. For frequencies 4, 6, 8, 12, and 16 kHz in the FI group, tone burst auditory thresholds increased after the revision surgery showing no recovery thereafter. Mean threshold shift at 6 months of follow- up is 19.8 dB ranging from 2 to 36dB for PI group and 33.14dB ranging from 8 to 48dB for FI group. Statistical analysis yields no significant differences between groups. It is feasible to perform a partial insertion of an electrode array and progress on a second surgical time to a full insertion (up to 270º). Hearing preservation is feasible for both procedures. Note that a minimal threshold deterioration is depicted among full insertion group, especially among high frequencies, with no statistical differences.
Toh, Sengwee; Reichman, Marsha E; Graham, David J; Hampp, Christian; Zhang, Rongmei; Butler, Melissa G; Iyer, Aarthi; Rucker, Malcolm; Pimentel, Madelyn; Hamilton, Jack; Lendle, Samuel; Fireman, Bruce H
2018-01-01
The cardiovascular safety of saxagliptin, a dipeptidyl-peptidase 4 inhibitor, compared with other antihyperglycemic treatments is not well understood. We prospectively examined the association between saxagliptin use and acute myocardial infarction (AMI). We identified patients aged ≥18 years, starting from the approval date of saxagliptin in 2009 and continuing through August 2014, using data from 18 Mini-Sentinel data partners. We conducted seven sequential assessments comparing saxagliptin separately with sitagliptin, pioglitazone, second-generation sulfonylureas, and long-acting insulin, using disease risk score (DRS) stratification and propensity score (PS) matching to adjust for potential confounders. Sequential testing kept the overall chance of a false-positive signal below 0.05 (one-sided) for each pairwise comparison. We identified 82,264 saxagliptin users and more than 1.5 times as many users of each comparator. At the end of surveillance, the DRS-stratified hazard ratios (HRs) (95% CI) were 1.08 (0.90-1.28) in the comparison with sitagliptin, 1.11 (0.87-1.42) with pioglitazone, 0.79 (0.64-0.98) with sulfonylureas, and 0.57 (0.46-0.70) with long-acting insulin. The corresponding PS-matched HRs were similar. Only one interim analysis of 168 analyses met criteria for a safety signal: the PS-matched saxagliptin-pioglitazone comparison from the fifth sequential analysis, which yielded an HR of 1.63 (1.12-2.37). This association diminished in subsequent analyses. We did not find a higher AMI risk in saxagliptin users compared with users of other selected antihyperglycemic agents during the first 5 years after U.S. Food and Drug Administration approval of the drug. © 2017 by the American Diabetes Association.
Li, Bo; Li, Hao; Dong, Li; Huang, Guofu
2017-11-01
In this study, we sought to investigate the feasibility of fast carotid artery MR angiography (MRA) by combining three-dimensional time-of-flight (3D TOF) with compressed sensing method (CS-3D TOF). A pseudo-sequential phase encoding order was developed for CS-3D TOF to generate hyper-intense vessel and suppress background tissues in under-sampled 3D k-space. Seven healthy volunteers and one patient with carotid artery stenosis were recruited for this study. Five sequential CS-3D TOF scans were implemented at 1, 2, 3, 4 and 5-fold acceleration factors for carotid artery MRA. Blood signal-to-tissue ratio (BTR) values for fully-sampled and under-sampled acquisitions were calculated and compared in seven subjects. Blood area (BA) was measured and compared between fully sampled acquisition and each under-sampled one. There were no significant differences between the fully-sampled dataset and each under-sampled in BTR comparisons (P>0.05 for all comparisons). The carotid vessel BAs measured from the images of CS-3D TOF sequences with 2, 3, 4 and 5-fold acceleration scans were all highly correlated with that of the fully-sampled acquisition. The contrast between blood vessels and background tissues of the images at 2 to 5-fold acceleration is comparable to that of fully sampled images. The images at 2× to 5× exhibit the comparable lumen definition to the corresponding images at 1×. By combining the pseudo-sequential phase encoding order, CS reconstruction, and 3D TOF sequence, this technique provides excellent visualizations for carotid vessel and calcifications in a short scan time. It has the potential to be integrated into current multiple blood contrast imaging protocol. Copyright © 2017. Published by Elsevier Inc.
Development of a multilayered association polymer system for sequential drug delivery
NASA Astrophysics Data System (ADS)
Chinnakavanam Sundararaj, Sharath kumar
As all the physiological processes in our body are controlled by multiple biomolecules, comprehensive treatment of certain disease conditions may be more effectively achieved by administration of more than one type of drug. Thus, the primary objective of this research was to develop a multilayered, polymer-based system for sequential delivery of multiple drugs. This particular device was designed aimed at the treatment of periodontitis, a highly prevalent oral inflammatory disease that affects 90% of the world population. This condition is caused by bacterial biofilm on the teeth, resulting in a chronic inflammatory response that leads to loss of alveolar bone and, ultimately, the tooth. Current treatment methods for periodontitis address specific parts of the disease, with no individual treatment serving as a complete therapy. The polymers used for the fabrication of this multilayered device consists of cellulose acetate phthalate (CAP) complexed with Pluronic F-127 (P). After evaluating morphology of the resulting CAPP system, in vitro release of small molecule drugs and a model protein was studied from both single and multilayered devices. Drug release from single-layered CAPP films followed zero-order kinetics related to surface erosion property of the association polymer. Release studies from multilayered CAPP devices showed the possibility of achieving intermittent release of one type of drug as well as sequential release of more than one type of drug. Mathematical modeling accurately predicted the release profiles for both single layer and multilayered devices. After the initial characterization of the CAPP system, the device was specifically modified to achieve sequential release of drugs aimed at the treatment of periodontitis. The four types of drugs used were metronidazole, ketoprofen, doxycycline, and simvastatin to eliminate infection, inhibit inflammation, prevent tissue destruction, and aid bone regeneration, respectively. To obtain different erosion times and achieve appropriate release profiles specific to the disease condition, the device was modified by increasing the number of layers or by inclusion of a slower eroding polymer layer. In all the cases, the device was able to release the four different drugs in the designed temporal sequence. Analysis of antibiotic and antiinflammatory bioactivity showed that drugs released from the devices retained 100% bioactivity. Following extensive studies on the in vitro sequential drug release from these devices, the in vivo drug release profiles were investigated. The CAPP devices with different release rates and dosage formulations were implanted in a rat calvarial onlay model, and the in vivo drug release and erosion was compared with in vitro results. In vivo studies showed sequential release of drugs comparable to those measured in vitro, with some difference in drug release rates observed. The present CAPP association polymer-based multilayer devices can be used for localized, sequential delivery of multiple drugs for the possible treatment of complex disease conditions, and perhaps for tissue engineering applications, that require delivery of more than one type of biomolecule. KEYWORDS: Multiple drug delivery, Periodontitis, Cellulose acetate phthalate, Pluronic F-127, Sequential drug release, in vitro drug release, in vivo drug release.
Sequential episodes of ethylene glycol poisoning in the same person.
Sugunaraj, Jaya Prakash; Thakur, Lokendra Kumar; Jha, Kunal Kishor; Bucaloiu, Ion Dan
2017-05-27
Ethylene glycol is a common alcohol found in many household products such as household hard surface cleaner, paints, varnish, auto glass cleaner and antifreeze. While extremely toxic and often fatal on ingestion, few cases with early presentation by the patient have resulted in death; thus, rapid diagnosis is paramount to effectively treating ethylene glycol poisoning. In this study, we compare two sequential cases of ethylene glycol poisoning in a single individual, which resulted in strikingly different outcomes. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Technical Reports Server (NTRS)
Lin, Qian; Allebach, Jan P.
1990-01-01
An adaptive vector linear minimum mean-squared error (LMMSE) filter for multichannel images with multiplicative noise is presented. It is shown theoretically that the mean-squared error in the filter output is reduced by making use of the correlation between image bands. The vector and conventional scalar LMMSE filters are applied to a three-band SIR-B SAR, and their performance is compared. Based on a mutliplicative noise model, the per-pel maximum likelihood classifier was derived. The authors extend this to the design of sequential and robust classifiers. These classifiers are also applied to the three-band SIR-B SAR image.
Capek, Stepan; Amrami, Kimberly K; Howe, Benjamin M; Collins, Mark S; Sandroni, Paola; Cheville, John C; Spinner, Robert J
2016-03-01
Endometriosis of the nerve often remains an elusive diagnosis. We report the first case of intraneural lumbosacral plexus endometriosis with sequential imaging at different phases of the menstrual cycle: during the luteal phase and menstruation. Compared to the first examination, the examination performed during the patient's period revealed the lumbosacral plexus larger and hyperintense on T2-weighted imaging. The intraneural endometriosis cyst was also larger and showed recent hemorrhage. Additionally, this case represents another example of perineural spread of endometriosis from the uterus to the lumbosacral plexus along the autonomic nerves and then distally to the sciatic nerve and proximally to the spinal nerves.
Revisiting Pneumatic Nail Gun Trigger Recommendations
Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley
2015-01-01
Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020
Silverman, Rachel K; Ivanova, Anastasia
2017-01-01
Sequential parallel comparison design (SPCD) was proposed to reduce placebo response in a randomized trial with placebo comparator. Subjects are randomized between placebo and drug in stage 1 of the trial, and then, placebo non-responders are re-randomized in stage 2. Efficacy analysis includes all data from stage 1 and all placebo non-responding subjects from stage 2. This article investigates the possibility to re-estimate the sample size and adjust the design parameters, allocation proportion to placebo in stage 1 of SPCD, and weight of stage 1 data in the overall efficacy test statistic during an interim analysis.
Glorion, M; Polard, V; Favereau, F; Hauet, T; Zal, F; Fadel, E; Sage, E
2017-10-25
We describe the results of adding a new biological agent HEMO 2 life ® to a standard preservation solution for hypothermic static lung preservation aiming to improve early functional parameters after lung transplantation. HEMO 2 life ® is a natural oxygen carrier extracted from Arenicola marina with high oxygen affinity developed as an additive to standard organ preservation solutions. Standard preservation solution (Perfadex ® ) was compared with Perfadex ® associated with HEMO 2 life ® and with sham animals after 24 h of hypothermic preservation followed by lung transplantation. During five hours of lung reperfusion, functional parameters and biomarkers expression in serum and in bronchoalveolar lavage fluid (BALF) were measured. After five hours of reperfusion, HEMO 2 life ® group led to significant improvement in functional parameters: reduction of graft vascular resistance (p < .05) and increase in graft oxygenation ratio (p < .05). Several ischemia-reperfusion related biomarkers showed positive trends in the HEMO 2 life ® group: expression of HMG B1 in serum tended to be lower in comparison (2.1 ± 0.8 vs. 4.6 ± 1.5) with Perfadex ® group, TNF-α and IL-8 in BALF were significantly higher in the two experimental groups compared to control (p < .05). During cold ischemia, expression of HIF1α and histology remained unchanged and similar to control. Supplementation of the Perfadex ® solution by an innovative oxygen carrier HEMO 2 life ® during hypothermic static preservation improves early graft function after prolonged cold ischemia in lung transplantation.
Fagnant, Christine Susan; Kossik, Alexandra Lynn; Zhou, Nicolette Angela; Sánchez-Gonzalez, Liliana; Falman, Jill Christin; Keim, Erika Karen; Linden, Yarrow; Scheibe, Alana; Barnes, Kilala Sayisha; Beck, Nicola Koren; Boyle, David S; Meschke, John Scott
2017-12-01
Environmental surveillance of poliovirus (PV) and other non-enveloped viruses can help identify silent circulation and is necessary to certify eradication. The bag-mediated filtration system is an efficient method to filter large volumes of environmental waters at field sites for monitoring the presence of viruses. As filters may require long transit times to off-site laboratories for processing, viral inactivation or overgrowth of bacteria and fungi can interfere with virus detection and quantification (Miki and Jacquet in Aquatic Microb Ecol 51(2):195-208, 2008). To evaluate virus survival over time on ViroCap ™ filters, the filters were seeded with PV type 1 (PV1) and/or MS2 and then dosed with preservatives or antibiotics prior to storage and elution. These filters were stored at various temperatures and time periods, and then eluted for PV1 and MS2 recovery quantification. Filters dosed with the preservative combination of 2% sodium benzoate and 0.2% calcium propionate had increased virus survival over time when stored at 25 °C, compared to samples stored at 25 °C with no preservatives. While elution within 24 h of filtration is recommended, if storage or shipping is required then this preservative mixture can help preserve sample integrity. Addition of an antibiotic cocktail containing cephapirin, gentamicin, and Proclin ™ 300 increased recovery after storage at 4 and 25 °C, when compared to storage with no antibiotics. The antibiotic cocktail can aid sample preservation if access to appropriate antibiotics storage is available and sample cold chain is unreliable. This study demonstrated that the use of preservatives or antibiotics is a simple, cost-effective method to improve virus detection from ViroCap cartridge filters over time.
Daull, Philippe; Buggage, Ronald; Lambert, Grégory; Faure, Marie-Odile; Serle, Janet; Wang, Rong-Fang; Garrigue, Jean-Sébastien
2012-10-01
Benzalkonium chloride (BAK), a common preservative in eye drops, can induce ocular surface toxicity that may decrease glaucoma therapy compliance. The ocular hypotensive effect, pharmacokinetic (PK) profiles, and local tolerance of a preservative-free latanoprost 0.005% cationic emulsion (Catioprost(®)), and a BAK-preserved latanoprost 0.005% solution (Xalatan(®)), were compared. The ocular hypotensive effect was evaluated in monkeys with elevated intraocular pressure (IOP) induced by laser photocoagulation of the trabecular meshwork. Each monkey (n=8) received both latanoprost formulations once daily for 5 consecutive treatment days in a crossover design with at least a 2-week washout period between treatments. IOP was measured at baseline (on day 1, no instillation), on vehicle treatment day (day 0), and on treatment days 1, 3, and 5 before drug instillation and then hourly for 6 h. In rabbits, the ocular and systemic concentrations of latanoprost free acid were determined following a single instillation and the local tolerance of twice daily instillations over 28 days was assessed. Both the preservative-free and BAK-preserved latanoprost formulations shared the same efficacy profile with the maximum IOP reduction occurring 2 h after each morning dose (-15%, -20%, and -26%; -15%, -23%, and -23% on days 1, 3, and 5, respectively) and lasting through 24 h. The equivalence in efficacy was confirmed by the PK data demonstrating similar area under the curves (AUCs). While both formulations were well tolerated, the incidence of conjunctival hyperemia was reduced by 42% with the BAK-free latanoprost cationic emulsion. In animal models, a preservative-free latanoprost cationic emulsion was as effective as Xalatan(®) for lowering IOP with an improved ocular tolerance profile.
Porting Gravitational Wave Signal Extraction to Parallel Virtual Machine (PVM)
NASA Technical Reports Server (NTRS)
Thirumalainambi, Rajkumar; Thompson, David E.; Redmon, Jeffery
2009-01-01
Laser Interferometer Space Antenna (LISA) is a planned NASA-ESA mission to be launched around 2012. The Gravitational Wave detection is fundamentally the determination of frequency, source parameters, and waveform amplitude derived in a specific order from the interferometric time-series of the rotating LISA spacecrafts. The LISA Science Team has developed a Mock LISA Data Challenge intended to promote the testing of complicated nested search algorithms to detect the 100-1 millihertz frequency signals at amplitudes of 10E-21. However, it has become clear that, sequential search of the parameters is very time consuming and ultra-sensitive; hence, a new strategy has been developed. Parallelization of existing sequential search algorithms of Gravitational Wave signal identification consists of decomposing sequential search loops, beginning with outermost loops and working inward. In this process, the main challenge is to detect interdependencies among loops and partitioning the loops so as to preserve concurrency. Existing parallel programs are based upon either shared memory or distributed memory paradigms. In PVM, master and node programs are used to execute parallelization and process spawning. The PVM can handle process management and process addressing schemes using a virtual machine configuration. The task scheduling and the messaging and signaling can be implemented efficiently for the LISA Gravitational Wave search process using a master and 6 nodes. This approach is accomplished using a server that is available at NASA Ames Research Center, and has been dedicated to the LISA Data Challenge Competition. Historically, gravitational wave and source identification parameters have taken around 7 days in this dedicated single thread Linux based server. Using PVM approach, the parameter extraction problem can be reduced to within a day. The low frequency computation and a proxy signal-to-noise ratio are calculated in separate nodes that are controlled by the master using message and vector of data passing. The message passing among nodes follows a pattern of synchronous and asynchronous send-and-receive protocols. The communication model and the message buffers are allocated dynamically to address rapid search of gravitational wave source information in the Mock LISA data sets.
Digital forensics: an analytical crime scene procedure model (ACSPM).
Bulbul, Halil Ibrahim; Yavuzcan, H Guclu; Ozel, Mesut
2013-12-10
In order to ensure that digital evidence is collected, preserved, examined, or transferred in a manner safeguarding the accuracy and reliability of the evidence, law enforcement and digital forensic units must establish and maintain an effective quality assurance system. The very first part of this system is standard operating procedures (SOP's) and/or models, conforming chain of custody requirements, those rely on digital forensics "process-phase-procedure-task-subtask" sequence. An acceptable and thorough Digital Forensics (DF) process depends on the sequential DF phases, and each phase depends on sequential DF procedures, respectively each procedure depends on tasks and subtasks. There are numerous amounts of DF Process Models that define DF phases in the literature, but no DF model that defines the phase-based sequential procedures for crime scene identified. An analytical crime scene procedure model (ACSPM) that we suggest in this paper is supposed to fill in this gap. The proposed analytical procedure model for digital investigations at a crime scene is developed and defined for crime scene practitioners; with main focus on crime scene digital forensic procedures, other than that of whole digital investigation process and phases that ends up in a court. When reviewing the relevant literature and interrogating with the law enforcement agencies, only device based charts specific to a particular device and/or more general perspective approaches to digital evidence management models from crime scene to courts are found. After analyzing the needs of law enforcement organizations and realizing the absence of crime scene digital investigation procedure model for crime scene activities we decided to inspect the relevant literature in an analytical way. The outcome of this inspection is our suggested model explained here, which is supposed to provide guidance for thorough and secure implementation of digital forensic procedures at a crime scene. In digital forensic investigations each case is unique and needs special examination, it is not possible to cover every aspect of crime scene digital forensics, but the proposed procedure model is supposed to be a general guideline for practitioners. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Sharma, Sandeep; Biswal, Badal Kumar; Kumari, Divya; Bindra, Pulkit; Kumar, Satish; Stobdan, Tsering; Shanmugam, Vijayakumar
2018-05-21
According to Food and Agriculture Organization 2015 report, post-harvest agricultural loss accounts for 20-50% annually; on the other hand, reports about preservatives toxicity are also increasing. Hence, preservative release with response to fruit requirement is desired. In this study, acid synthesized in the overripe fruits was envisaged to cleave acid labile hydrazone to release preservative salicylaldehyde from graphene oxide (GO). To maximize loading and to overcome the challenge of GO reduction by hydrazine, two-step activation with ethylenediamine and 4-nitrophenyl chloroformate respectively, are followed. The final composite shows efficient preservative release with the stimuli of the overripe fruit juice and improves the fruit shelf life. The composite shows less toxicity as compared to the free preservative along with the additional scope to reuse. The composite was vacuum-filtered through a 0.4 μm filter paper, to prepare a robust wrapper for the fruit storage.
Effects of preservatives on stable isotope analyses of four marine species
NASA Astrophysics Data System (ADS)
Carabel, Sirka; Verísimo, Patricia; Freire, Juan
2009-04-01
The aim of the present study is to quantify the effect of formalin-ethanol preservation on the carbon and nitrogen stable isotope signatures of four taxonomical groups of marine species ( Himanthalia elongata, Anemonia sulcata, Mytilus galloprovincialis and Patella vulgata). To examine temporal changes in the effects of preservation and to determine if preservation induced predictable shifts in δ13C and δ15N signatures, repeated analyses were carried out after 6, 12 and 24 months of preservation. Data from our study showed highly variable effects of the formalin-ethanol preservation on carbon and nitrogen isotope signatures between species. The use of a general correction factor was not possible, or else it should be species-specific. Differences in nitrogen isotopic values between preserved and unpreserved samples were minor compared to the assumed enrichment between trophic levels. The combined use of data from preserved and unpreserved samples could lead to biases in the estimation of the trophic level of organisms. Changes that preservatives caused in carbon values were variable between species and not always small enough to be ignored. So the use of data from preserved samples could change the interpretation of the mixing models used to determine the importance of multiple sources of carbon. In order to elucidate the effects that preservatives have in other species, further studies will be necessary.
López-Pelayo, Iratxe; Gutiérrez-Romero, Javier María; Armada, Ana Isabel Mangano; Calero-Ruiz, María Mercedes; Acevedo-Yagüe, Pablo Javier Moreno de
2018-04-26
To compare embryo quality, fertilization, implantation, miscarriage and clinical pregnancy rates for embryos cultured in two different commercial culture media until D-2 or D-3. In this retrospective study, we analyzed 189 cycles performed in 2016. Metaphase II oocytes were microinjected and allocated into single medium (SAGE 1-STEP, Origio) until transferred, frozen or discarded; or, if sequential media were used, the oocytes were cultured in G1-PLUSTM (Vitrolife) up to D-2 or D-3 and in G2-PLUSTM (Vitrolife) to transfer. On the following day, the oocytes were checked for normal fertilization and on D-2 and D-3 for morphological classification. Statistical analysis was performed using the chi-square and Mann-Whitney tests in PASW Statistics 18.0. The fertilization rates were 70.07% for single and 69.11% for sequential media (p=0.736). The mean number of embryos with high morphological quality (class A/B) was higher in the single medium than in the sequential media: D-2 [class A (190 vs. 107, p<0.001), B (133 vs. 118, p=0.018)]; D-3 [class A (40 vs. 19, p=0.048) but without differences in class B (40 vs. 49)]. Consequently, a higher number of embryos cultured in single medium were frozen: 197 (21.00%) vs. sequential: 102 (11.00%), p<0.001. No differences were found in implantation rates (30.16% vs. 25.57%, p=0.520), clinical pregnancy rates (55.88% vs. 41.05%, p=0.213), or miscarriage rates (14.29% vs. 9.52%, p=0.472). Embryo culture in single medium yields greater efficiency per cycle than in sequential media. Higher embryo quality and quantity were achieved, resulting in more frozen embryos. There were no differences in clinical pregnancy rates.
Bhoomiboonchoo, Piraya; Nisalak, Ananda; Chansatiporn, Natkamol; Yoon, In-Kyu; Kalayanarooj, Siripen; Thipayamongkolgul, Mathuros; Endy, Timothy; Rothman, Alan L; Green, Sharone; Srikiatkhachorn, Anon; Buddhari, Darunee; Mammen, Mammen P; Gibbons, Robert V
2015-03-14
The effect of prior dengue virus (DENV) exposure on subsequent heterologous infection can be beneficial or detrimental depending on many factors including timing of infection. We sought to evaluate this effect by examining a large database of DENV infections captured by both active and passive surveillance encompassing a wide clinical spectrum of disease. We evaluated datasets from 17 years of hospital-based passive surveillance and nine years of cohort studies, including clinical and subclinical DENV infections, to assess the outcomes of sequential heterologous infections. Chi square or Fisher's exact test was used to compare proportions of infection outcomes such as disease severity; ANOVA was used for continuous variables. Multivariate logistic regression was used to assess risk factors for infection outcomes. Of 38,740 DENV infections, two or more infections were detected in 502 individuals; 14 had three infections. The mean ages at the time of the first and second detected infections were 7.6 ± 3.0 and 11.2 ± 3.0 years. The shortest time between sequential infections was 66 days. A longer time interval between sequential infections was associated with dengue hemorrhagic fever (DHF) in the second detected infection (OR 1.3, 95% CI 1.2-1.4). All possible sequential serotype pairs were observed among 201 subjects with DHF at the second detected infection, except DENV-4 followed by DENV-3. Among DENV infections detected in cohort subjects by active study surveillance and subsequent non-study hospital-based passive surveillance, hospitalization at the first detected infection increased the likelihood of hospitalization at the second detected infection. Increasing time between sequential DENV infections was associated with greater severity of the second detected infection, supporting the role of heterotypic immunity in both protection and enhancement. Hospitalization was positively associated between the first and second detected infections, suggesting a possible predisposition in some individuals to more severe dengue disease.
Zhu, Liangsong; Wu, Guangyu; Huang, Jiwei; Wang, Jianfeng; Zhang, Ruiyun; Kong, Wen; Xue, Wei; Huang, Yiran; Chen, Yonghui; Zhang, Jin
2017-05-01
To compare the renal function preservation between laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy. Data were analyzed from 246 patients who underwent laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for solitary cT1a renal cell carcinoma from January 2013 to July 2015. To reduce the intergroup difference, we used a 1:1 propensity matching analysis. The functional renal parenchyma volume preservation were measured preoperative and 12 months after surgery. The total renal function recovery and spilt GFR was compared. Multivariable logistic analysis was used for predictive factors for renal function decline. After 1:1 propensity matching, each group including 100 patients. Patients in the laparoscopic radio frequency ablation assisted tumor enucleation had a smaller decrease in estimate glomerular filtration rate at 1 day (-7.88 vs -20.01%, p < 0.001), 3 months (-2.31 vs -10.39%, p < 0.001), 6 months (-2.16 vs -7.99%, p = 0.015), 12 months (-3.26 vs -8.03%, p = 0.012) and latest test (-3.24 vs -8.02%, p = 0.040), also had better functional renal parenchyma volume preservation (89.19 vs 84.27%, p < 0.001), lower decrease of the spilt glomerular filtration rate (-9.41 vs -17.13%, p < 0.001) at 12 months. The functional renal parenchyma volume preservation, warm ischemia time and baseline renal function were the important independent factors in determining long-term functional recovery. The laparoscopic radio frequency ablation assisted tumor enucleation technology has unique advantage and potential in preserving renal parenchyma without ischemia damage compared to conventional laparoscopic partial nephrectomy, and had a better outcome, thus we recommend this technique in selected T1a patients.
Qiao, Wei-Hua; Liu, Peng; Hu, Dan; Al Shirbini, Mahmoud; Zhou, Xian-Ming; Dong, Nian-Guo
2018-02-01
Antigenicity of xenogeneic tissues is the major obstacle to increased use of these materials in clinical medicine. Residual xenoantigens in decellularized tissue elicit the immune response after implantation, causing graft failure. With this in mind, the potential use is proposed of three protein solubilization-based protocols for porcine aortic valve leaflets decellularization. It was demonstrated that hydrophile solubilization alone achieved incomplete decellularization; lipophile solubilization alone (LSA) completely removed all cells and two most critical xenoantigens - galactose-α(1,3)-galactose (α-Gal) and major histocompatibility complex I (MHC I) - but caused severe alterations of the structure and mechanical properties; sequential hydrophile and lipophile solubilization (SHLS) resulted in a complete removal of cells, α-Gal and MHC I, and good preservation of the structure and mechanical properties. In contrast, a previously reported method using Triton X-100, sodium deoxycholate and IGEPAL CA-630 resulted in a complete removal of all cells and MHC I, but with remaining α-Gal epitope. LSA- and SHLS-treated leaflets showed significantly reduced leucocyte activation (polymorphonuclear elastase) upon interaction with human blood in vitro. When implanted subdermally in rats for 6 weeks, LSA- or SHLS-treated leaflets were presented with more biocompatible implants and all four decellularized leaflets were highly resistant to calcification. These findings illustrate that the SHLS protocol could be considered as a promising decellularization method for the decellularization of xenogeneic tissues in tissue engineering and regenerative medicine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Heisler, Morgan; Lee, Sieun; Mammo, Zaid; Jian, Yifan; Ju, Myeong Jin; Miao, Dongkai; Raposo, Eric; Wahl, Daniel J.; Merkur, Andrew; Navajas, Eduardo; Balaratnasingam, Chandrakumar; Beg, Mirza Faisal; Sarunic, Marinko V.
2017-02-01
High quality visualization of the retinal microvasculature can improve our understanding of the onset and development of retinal vascular diseases, which are a major cause of visual morbidity and are increasing in prevalence. Optical Coherence Tomography Angiography (OCT-A) images are acquired over multiple seconds and are particularly susceptible to motion artifacts, which are more prevalent when imaging patients with pathology whose ability to fixate is limited. The acquisition of multiple OCT-A images sequentially can be performed for the purpose of removing motion artifact and increasing the contrast of the vascular network through averaging. Due to the motion artifacts, a robust registration pipeline is needed before feature preserving image averaging can be performed. In this report, we present a novel method for a GPU-accelerated pipeline for acquisition, processing, segmentation, and registration of multiple, sequentially acquired OCT-A images to correct for the motion artifacts in individual images for the purpose of averaging. High performance computing, blending CPU and GPU, was introduced to accelerate processing in order to provide high quality visualization of the retinal microvasculature and to enable a more accurate quantitative analysis in a clinically useful time frame. Specifically, image discontinuities caused by rapid micro-saccadic movements and image warping due to smoother reflex movements were corrected by strip-wise affine registration estimated using Scale Invariant Feature Transform (SIFT) keypoints and subsequent local similarity-based non-rigid registration. These techniques improve the image quality, increasing the value for clinical diagnosis and increasing the range of patients for whom high quality OCT-A images can be acquired.
The coordination patterns observed when two hands reach-to-grasp separate objects.
Bingham, Geoffrey P; Hughes, Kirstie; Mon-Williams, Mark
2008-01-01
What determines coordination patterns when both hands reach to grasp separate objects at the same time? It is known that synchronous timing is preferred as the most stable mode of bimanual coordination. Nonetheless, normal unimanual prehension behaviour predicts asynchrony when the two hands reach towards unequal targets, with synchrony restricted to targets equal in size and distance. Additionally, sufficiently separated targets require sequential looking. Does synchrony occur in all cases because it is preferred in bimanual coordination or does asynchrony occur because of unimanual task constraints and the need for sequential looking? We investigated coordinative timing when participants (n = 8) moved their right (preferred) hand to the same object at a fixed distance but the left hand to objects of different width (3, 5, and 7 cm) and grip surface size (1, 2, and 3 cm) placed at different distances (20, 30, and 40 cm) over 270 randomised trials. The hand movements consisted of two components: (1) an initial component (IC) during which the hand reached towards the target while forming an appropriate grip aperture, stopping at (but not touching) the object; (2) a completion component (CC) during which the finger and thumb closed on the target. The two limbs started the IC together but did not interact until the deceleration phase when evidence of synchronisation began to appear. Nonetheless, asynchronous timing was present at the end of the IC and preserved through the CC even with equidistant targets. Thus, there was synchrony but requirements for visual information ultimately yielded asynchronous coordinative timing.
Modeling the evolution of a ramp-flat-ramp thrust system: A geological application of DynEarthSol2D
NASA Astrophysics Data System (ADS)
Feng, L.; Choi, E.; Bartholomew, M. J.
2013-12-01
DynEarthSol2D (available at http://bitbucket.org/tan2/dynearthsol2) is a robust, adaptive, two-dimensional finite element code that solves the momentum balance and the heat equation in Lagrangian form using unstructured meshes. Verified in a number of benchmark problems, this solver uses contingent mesh adaptivity in places where shear strain is focused (localization) and a conservative mapping assisted by marker particles to preserve phase and facies boundaries during remeshing. We apply this cutting-edge geodynamic modeling tool to the evolution of a thrust fault with a ramp-flat-ramp geometry. The overall geometry of the fault is constrained by observations in the northern part of the southern Appalachian fold and thrust belt. Brittle crust is treated as a Mohr-Coulomb plastic material. The thrust fault is a zone of a finite thickness but has a lower cohesion and friction angle than its surrounding rocks. When an intervening flat separates two distinct sequential ramps crossing different stratigraphic intervals, the thrust system will experience more complex deformations than those from a single thrust fault ramp. The resultant deformations associated with sequential ramps would exhibit a spectrum of styles, of which two end members correspond to ';overprinting' and ';interference'. Reproducing these end-member styles as well as intermediate ones, our models show that the relative importance of overprinting versus interference is a sensitive function of initial fault geometry and hanging wall displacement. We further present stress and strain histories extracted from the models. If clearly distinguishable, they will guide the interpretation of field observations on thrust faults.
Real and Non-Real Time Interaction: Unraveling Multiple Threads of Discourse.
ERIC Educational Resources Information Center
Black, Steven D.; And Others
1983-01-01
Compares discourse in several different media and finds that strict sequentiality is not a universal feature of discourse. Concludes that discourse in nonreal time media, such as electronic message systems, has multiple threads. (FL)
Tay, J H; Liu, Q S; Liu, Y
2002-08-01
Aerobic granules were cultivated in two column-type sequential aerobic sludge blanket reactors fed with glucose and acetate, respectively. The characteristics of aerobic granules were investigated. Results indicated that the glucose- and acetate-fed granules have comparable characteristics in terms of settling velocity, size, shape, biomass density, hydrophobicity, physical strength, microbial activity and storage stability. Substrate component does not seem to be a key factor on the formation of aerobic granules. However, microbial diversity of the granules is closely associated with the carbon sources supplied to the reactors. Compared with the conventional activated sludge flocs, aerobic granules exhibit excellent physical characteristics that would be essential for industrial application. This research provides a complete set of characteristics data of aerobic granules grown on glucose and acetate, which would be useful for further development of aerobic granules-based compact bioreactor for handling high strength organic wastewater.
Improved solution accuracy for Landsat-4 (TDRSS-user) orbit determination
NASA Technical Reports Server (NTRS)
Oza, D. H.; Niklewski, D. J.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.
1994-01-01
This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using a Prototype Filter Smoother (PFS), with the accuracy of an established batch-least-squares system, the Goddard Trajectory Determination System (GTDS). The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and convariances for the sequential case) of solutions produced by the batch and sequential methods. The filtered and smoothed PFS orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 15 meters.
Lhakhang, Pempa; Gholami, Maryam; Knoll, Nina; Schwarzer, Ralf
2015-01-01
A sequential intervention to facilitate the adoption and maintenance of dental flossing was conducted among 205 students in India, aged 18-26 years. Two experimental groups received different treatment sequences and were observed at three assessment points, 34 days apart. One group received first a motivational intervention (intention, outcome expectancies, and risk perception, followed by a self-regulatory intervention (planning, self-efficacy, and action control). The second group received the same intervention in the opposite order. Both intervention sequences yielded gains in terms of flossing, planning, self-efficacy, and action control. However, at Time 2, those who had received the self-regulatory intervention first, were superior to their counterparts who had received the motivational intervention first. At Time 3, differences vanished as everyone had then received both interventions. Thus, findings highlight the benefits of a self-regulatory compared to a mere motivational intervention.
A Bayesian approach to tracking patients having changing pharmacokinetic parameters
NASA Technical Reports Server (NTRS)
Bayard, David S.; Jelliffe, Roger W.
2004-01-01
This paper considers the updating of Bayesian posterior densities for pharmacokinetic models associated with patients having changing parameter values. For estimation purposes it is proposed to use the Interacting Multiple Model (IMM) estimation algorithm, which is currently a popular algorithm in the aerospace community for tracking maneuvering targets. The IMM algorithm is described, and compared to the multiple model (MM) and Maximum A-Posteriori (MAP) Bayesian estimation methods, which are presently used for posterior updating when pharmacokinetic parameters do not change. Both the MM and MAP Bayesian estimation methods are used in their sequential forms, to facilitate tracking of changing parameters. Results indicate that the IMM algorithm is well suited for tracking time-varying pharmacokinetic parameters in acutely ill and unstable patients, incurring only about half of the integrated error compared to the sequential MM and MAP methods on the same example.
Randall, Sean M; Ferrante, Anna M; Boyd, James H; Brown, Adrian P; Semmens, James B
2016-08-01
The statistical linkage key (SLK-581) is a common tool for record linkage in Australia, due to its ability to provide some privacy protection. However, newer privacy-preserving approaches may provide greater privacy protection, while allowing high-quality linkage. To evaluate the standard SLK-581, encrypted SLK-581 and a newer privacy-preserving approach using Bloom filters, in terms of both privacy and linkage quality. Linkage quality was compared by conducting linkages on Australian health datasets using these three techniques and examining results. Privacy was compared qualitatively in relation to a series of scenarios where privacy breaches may occur. The Bloom filter technique offered greater privacy protection and linkage quality compared to the SLK-based method commonly used in Australia. The adoption of new privacy-preserving methods would allow both greater confidence in research results, while significantly improving privacy protection. © The Author(s) 2016.
Phillips, M. Joe; Walker, Tiffany A.; Choi, Hee-young; Faulkner, Amanda E.; Kim, Moon K.; Sidney, Sheree; Boyd, Amber; Nickerson, John M.; Boatright, Jeffrey H.; Pardue, Machelle T.
2008-01-01
Purpose Retinitis Pigmentosa (RP) is a progressive neurodegenerative disease resulting in blindness for which there is no current treatment. While the members of the family of RP diseases differ in etiology, their outcomes are the same: apoptosis of rods followed by cones. Recently, the bile acid, tauroursodeoxycholic acid (TUDCA), has been shown to have anti-apoptotic properties in neurodegenerative diseases, including those of the retina. In this study we examine the efficacy of TUDCA on preserving rod and cone function and morphology at post-natal day 30 (P30) in the rd10 mouse, a model of RP. Methods Wild-type C57BL/6J and rd10 mice were systemically injected with TUDCA (500 mg/kg) every three days from P6-P30 and compared to vehicle (0.15M NaHCO3). At P30, retinal function was measured with electroretinography (ERG) and morphological preservation of the rods and cones assessed with immunohistochemistry. Results Dark-adapted ERG responses were two-fold greater in rd10 mice treated with TUDCA compared to vehicle, while light-adapted responses were two-fold larger in TUDCA-treated mice compared to controls, at the brightest ERG flash intensities. TUDCA-treated rd10 retinas had five-fold more photoreceptors than vehicle-treated. TUDCA treatments did not alter retinal function or morphology of wild-type mice when administered to age-matched mice. Conclusions TUDCA is efficacious and safe in preserving vision in the rd10 mouse model of RP when treated between P6 and P30. At P30, a developmental stage at which nearly all rods are absent in the rd10 mouse model of RP, TUDCA treatment preserved both rod and cone function and greatly preserved overall photoreceptor numbers. PMID:18436848
Tachibana, Hidekazu; Takagi, Toshio; Kondo, Tsunenori; Ishida, Hideki; Tanabe, Kazunari
2018-04-01
To compare surgical outcomes, including renal function and the preserved renal parenchymal volume, between robot-assisted laparoscopic partial nephrectomy and laparoscopic partial nephrectomy using propensity score-matched analyses. In total, 253 patients, with a normal contralateral kidney, who underwent laparoscopic partial nephrectomy (n = 131) or robot-assisted laparoscopic partial nephrectomy (n = 122) with renal arterial clamping between 2010 and 2015, were included. Patients' background and tumor factors were adjusted by propensity score matching. Surgical outcomes, including postoperative renal function, complications, warm ischemia time and preserved renal parenchymal volume, evaluated by volumetric analysis, were compared between the surgical procedures. After matching, 64 patients were assigned to each group. The mean age was 56-57 years, and the mean tumor size was 22 mm. Approximately 50% of patients had low complexity tumors (RENAL nephrometry score 4-7). The incidence rate of acute kidney failure was significantly lower in the robot-assisted laparoscopic partial nephrectomy (11%) than laparoscopic partial nephrectomy (23%) group (P = 0.049), and warm ischemia time shorter in the robot-assisted laparoscopic partial nephrectomy (17 min) than laparoscopic partial nephrectomy (25 min) group (P < 0.0001). The preservation rate of renal function, measured by the estimated glomerular filtration rate, at 6 months post-surgery was 96% for robot-assisted laparoscopic partial nephrectomy and 90% for laparoscopic partial nephrectomy (P < 0.0001). The preserved renal parenchymal volume was higher for robot-assisted laparoscopic partial nephrectomy (89%) than laparoscopic partial nephrectomy (77%; P < 0.0001). The rate of perioperative complications, surgical margin status and length of hospital stay were equivalent for both techniques. Robot-assisted laparoscopic partial nephrectomy allows to achieve better preservation of renal function and parenchymal volume than laparoscopic partial nephrectomy. © 2018 The Japanese Urological Association.