NASA Astrophysics Data System (ADS)
Yang, Henglong; Chang, Wen-Cheng; Lin, Yu-Hsuan; Chen, Ming-Hong
2017-08-01
The distinguishable and non-distinguishable 6-bit (64) grayscales of green and red organic light-emitting diode (OLED) were experimentally investigated by using high-sensitive photometric instrument. The feasibility of combining external detection system for quality engineering to compensate the grayscale loss based on preset grayscale tables was also investigated by SPICE simulation. The degradation loss of OLED deeply affects image quality as grayscales become inaccurate. The distinguishable grayscales are indicated as those brightness differences and corresponding current increments are differentiable by instrument. The grayscales of OLED in 8-bit (256) or higher may become nondistinguishable as current or voltage increments are in the same order of noise level in circuitry. The distinguishable grayscale tables for individual red, green, blue, and white colors can be experimentally established as preset reference for quality engineering (QE) in which the degradation loss is compensated by corresponding grayscale numbers shown in preset table. The degradation loss of each OLED colors is quantifiable by comparing voltage increments to those in preset grayscale table if precise voltage increments are detectable during operation. The QE of AMOLED can be accomplished by applying updated grayscale tables. Our preliminary simulation result revealed that it is feasible to quantify degradation loss in terms of grayscale numbers by using external detector circuitry.
Infrared Sensor Readout Design
1975-11-01
Line Replaceable Unit LT Level Translator MRT Minimum Resolvable Temperature MTF Modulation Transfer Function PC Printed Circuit SCCCD Surface...reduced, not only will the aliased noise increase, but signal aliasing will also start to occur. Atlbe display level this means that sharp edges could...converted from a quantity ol charge to a voltage- level shift by the action ol the precharge pulse that presets the potential on the output diode node to
Kember, Sally A; Hansen, Vibeke N; Fast, Martin F; Nill, Simeon; McDonald, Fiona; Ahmed, Merina; Thomas, Karen; McNair, Helen A
2016-07-01
To evaluate three image acquisition presets for four-dimensional cone beam CT (CBCT) to identify an optimal preset for lung tumour image quality while minimizing dose and acquisition time. Nine patients undergoing radical conventionally fractionated radiotherapy for lung cancer had verification CBCTs acquired using three presets: Preset 1 on Day 1 (11 mGy dose, 240 s acquisition time), Preset 2 on Day 2 (9 mGy dose, 133 s acquisition time) and Preset 3 on Day 3 (9 mGy dose, 67 s acquisition time). The clarity of the tumour and other thoracic structures, and the acceptability of the match, were retrospectively graded by visual grading analysis (VGA). Logistic regression was used to identify the most appropriate preset and any factors that might influence the result. Presets 1 and 2 met a clinical requirement of 75% of structures to be rated "Clear" or above and 75% of matches to be rated "Acceptable" or above. Clarity is significantly affected by preset, patient, observer and structure. Match acceptability is significantly affected by preset. The application of VGA in this initial study enabled a provisional selection of an optimal preset (Preset 2) to be made. This was the first application of VGA to the investigation of presets for CBCT.
Condition sensor system and method
NASA Technical Reports Server (NTRS)
Polhemus, J. T.; Morgan, J. E.; Mandell, A. (Inventor)
1978-01-01
The condition sensor system comprises a condition detector which produces a pulse when a parameter of the monitored condition exceeds a desired threshold. A resettable condition counter counts each pulse. A resettable timer is preset to produce a particular time frame. The counter produces a condition signal when the accumulated number of pulses within the time frame is equal to or greater than a preset count. Control means responsive to the incoming pulses and to the condition signal produce control signals that control utilization devices. After a suitable delay, the last detected pulse simultaneously resets the pulse counter and the timer, and prepares them for sensing another condition occurrence within the time frame. The invention has particular utility in the process of detecting rocking motions of blind people. A controlled, audible, bio-feedback signal is provided which constitutes a warning to the blind person that he is rocking.
40 CFR 62.14690 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2011 CFR
2011-07-01
... alarm system that will sound automatically when an increase in relative particulate matter emissions over a preset level is detected. The alarm must be located where it is easily heard by plant operating personnel. (7) For positive pressure fabric filter systems, a bag leak detection system must be installed in...
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... time, but means may be provided to permit completion of any single exposure of the series in process.... Means shall be provided to terminate the exposure at a preset time interval, a preset product of current and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except...
SU-E-J-07: IGRT Gently: Evaluating Imaging Dose in Phantoms of Different Sizes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morris, B; Duggar, W; Stanford, J
Purpose: IGRT imaging procedures have emerged as a common method of patient position verification in radiotherapy, though imaging dose is generally neglected in the treatment plan. Consequently, evaluating and optimizing the dose from these procedures is worthwhile. This process is especially important for children, who are more radiosensitive than adults. The aim of this work was to gain some understanding of the relative doses involved with various XVI-preset parameters for an “adult” and “child” phantom set, with the hopes that imaging dose for a child can be reduced. Methods: 32 and 16cm CTDI-phantoms were used as surrogates for adult andmore » child torsos, respectively. Dose was measured in the central and peripheral chamber positions of the phantoms. CBCT scans were made for both phantoms using Elekta’s Chest-preset to establish a dose baseline. The child-phantom was then scanned using the Elekta Head and Neck (HN) preset. A modified HN-preset (named Peds Abd-pelvis) was also created with a doubled mAs to maintain a reduction in dose to the child-phantom (relative to the baseline), while providing clinically-usable image quality. Results: The baseline dose to the child-phantom from the Chest-preset was 310% that of the adult-phantom for the center chamber position and 150% at the periphery. An average dose reduction of 97% was obtained in the childphantom by switching from the Chest-preset to the HN-preset, while the Peds Abd-pelvis-preset similarly reduced the dose by an average of 92%. Conclusion: XVI-preset parameters significantly affect dose, and should be optimized to reduce dose, while ensuring clinically-usable image quality. Using a modified imaging preset (Peds Abd-pelvis-preset) greatly reduced the dose to the child-phantom compared to the dose for the Chest-preset for both the child and adult-phantoms. This outcome provides support for the development of child-specific protocols for IGRT imaging in pediatric patients.« less
NASA Astrophysics Data System (ADS)
Gromov, V. A.; Sharygin, G. S.; Mironov, M. V.
2012-08-01
An interval method of radar signal detection and selection based on non-energetic polarization parameter - the ellipticity angle - is suggested. The examined method is optimal by the Neumann-Pearson criterion. The probability of correct detection for a preset probability of false alarm is calculated for different signal/noise ratios. Recommendations for optimization of the given method are provided.
System Detects Vibrational Instabilities
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr.
1990-01-01
Sustained vibrations at two critical frequencies trigger diagnostic response or shutdown. Vibration-analyzing electronic system detects instabilities of combustion in rocket engine. Controls pulse-mode firing of engine and identifies vibrations above threshold amplitude at 5.9 and/or 12kHz. Adapted to other detection and/or control schemes involving simultaneous real-time detection of signals above or below preset amplitudes at two or more specified frequencies. Potential applications include rotating machinery and encoders and decoders in security systems.
Detection device for hazardous materials
Partin, Judy K.; Grey, Alan E.
1994-01-01
A detection device that is activated by the interaction of a hazardous chcal with a coating interactive with said chemical on an optical fiber thereby reducing the amount of light passing through the fiber to a light detector. A combination of optical filters separates the light into a signal beam and a reference beam which after detection, appropriate amplification, and comparison with preset internal signals, activates an alarm means if a predetermined level of contaminant is observed.
Detection device for hazardous materials
Partin, Judy K.; Grey, Alan E.
1994-04-05
A detection device that is activated by the interaction of a hazardous chcal with a coating interactive with said chemical on an optical fiber thereby reducing the amount of light passing through the fiber to a light detector. A combination of optical filters separates the light into a signal beam and a reference beam which after detection, appropriate amplification, and comparison with preset internal signals, activates an alarm means if a predetermined level of contaminant is observed.
NASA Technical Reports Server (NTRS)
Houts, R. C.; Burlage, D. W.
1972-01-01
A time domain technique is developed to design finite-duration impulse response digital filters using linear programming. Two related applications of this technique in data transmission systems are considered. The first is the design of pulse shaping digital filters to generate or detect signaling waveforms transmitted over bandlimited channels that are assumed to have ideal low pass or bandpass characteristics. The second is the design of digital filters to be used as preset equalizers in cascade with channels that have known impulse response characteristics. Example designs are presented which illustrate that excellent waveforms can be generated with frequency-sampling filters and the ease with which digital transversal filters can be designed for preset equalization.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) The bag leak detection system must have an alarm that will sound automatically when it detects an increase in relative PM emissions greater than a preset level. (d) The alarm must be located in an area where appropriate plant personnel will be able to hear it. (e) For a positive-pressure fabric filter...
[Pharmaceutical logistic in turnover of pharmaceutical products of Azerbaijan].
Dzhalilova, K I
2009-11-01
Development of pharmaceutical logistic system model promotes optimal strategy for pharmaceutical functioning. The goal of such systems is organization of pharmaceutical product's turnover in required quantity and assortment, at preset time and place, at a highest possible degree of consumption readiness with minimal expenses and qualitative service. Organization of the optimal turnover chain in the region is offered to start from approximate classification of medicaments by logistic characteristics. Supplier selection was performed by evaluation of timeliness of delivery, quality of delivered products (according to the minimum acceptable level of quality) and time-keeping of time spending for orders delivery.
Operation and testing of Mark 10 Mod 3 underwater breathing apparatus
NASA Technical Reports Server (NTRS)
Milwee, W. I., Jr.
1972-01-01
Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.
NASA Astrophysics Data System (ADS)
Cui, Chenxuan
When cognitive radio (CR) operates, it starts by sensing spectrum and looking for idle bandwidth. There are several methods for CR to make a decision on either the channel is occupied or idle, for example, energy detection scheme, cyclostationary detection scheme and matching filtering detection scheme [1]. Among them, the most common method is energy detection scheme because of its algorithm and implementation simplicities [2]. There are two major methods for sensing, the first one is to sense single channel slot with varying bandwidth, whereas the second one is to sense multiple channels and each with same bandwidth. After sensing periods, samples are compared with a preset detection threshold and a decision is made on either the primary user (PU) is transmitting or not. Sometimes the sensing and decision results can be erroneous, for example, false alarm error and misdetection error may occur. In order to better control error probabilities and improve CR network performance (i.e. energy efficiency), we introduce cooperative sensing; in which several CR within a certain range detect and make decisions on channel availability together. The decisions are transmitted to and analyzed by a data fusion center (DFC) to make a final decision on channel availability. After the final decision is been made, DFC sends back the decision to the CRs in order to tell them to stay idle or start to transmit data to secondary receiver (SR) within a preset transmission time. After the transmission, a new cycle starts again with sensing. This thesis report is organized as followed: Chapter II review some of the papers on optimizing CR energy efficiency. In Chapter III, we study how to achieve maximal energy efficiency when CR senses single channel with changing bandwidth and with constrain on misdetection threshold in order to protect PU; furthermore, a case study is given and we calculate the energy efficiency. In Chapter IV, we study how to achieve maximal energy efficiency when CR senses multiple channels and each channel with same bandwidth, also, we preset a misdetection threshold and calculate the energy efficiency. A comparison will be shown between two sensing methods at the end of the chapter. Finally, Chapter V concludes this thesis.
Chuang, Han-Sheng; Chen, Yu-Ju; Cheng, Hui-Pin
2018-03-15
Diffusometry is sensitive to geometric changes of particles. Target antigens can be detected through diffusivity changes resulting from their immunoreactions by functionalizing particle surface with a specific antibody. Considering that Brownian motion is a self-driven phenomenon, diffusometric immunosensing features several characteristics, such as no-washing steps, rapid detection, high flexibility, and high sensitivity. Until recently, this technique has been applied to many biomedical fields, such as monitoring of microorganism motility and diagnosis of diseases with biomarkers. Despite the abovementioned advantages, diffusivity changes in conventional diffusometry can be compromised at low-abundance antigens because proteins are much smaller than capture particles. To overcome such restriction, we present an improved diffusometric immunosensing technique by grafting additional gold nanoparticles (AuNPs) to capture particles to enhance size changes. A diabetic retinopathy (DR) biomarker, tumor necrosis factor-α was selected to evaluate the proposed immunosensing technique. Spherical AuNPs showed better enhancement than rod-like AuNPs during measurement. Limit of detection was improved by at least 100-fold down to 10pg/mL. A dichotomous method was also developed to enable rapid detection and avoid tedious calibration. The relationship of concentrations between the two solutions used can be explicitly determined by comparing diffusivity of an unknown concentration of target molecules with that of a reference solution. Minimum discernible concentration reached as low as twofold higher or lower than basal concentration. Tear samples were collected from four volunteers, including three healthy subjects and one proliferative DR patient to prove the concept in diagnosis of the disease. All data showed good agreement with preset conditions. The technique eventually provides an insight into rapid diagnoses of diseases in the early stage. Copyright © 2017 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Rodriguez, Billie Jo
2013-01-01
The Preschool-Wide Evaluation Tool (PreSET; Steed & Pomerleau, 2012) is published by Paul H. Brookes Publishing Company in Baltimore, MD. The PreSET purports to measure universal and program-wide features of early childhood programs' implementation fidelity of program-wide positive behavior intervention and support (PW-PBIS) and is,…
CR softcopy display presets based on optimum visualization of specific findings
NASA Astrophysics Data System (ADS)
Andriole, Katherine P.; Gould, Robert G.; Webb, W. R.
1999-07-01
The purpose of this research is to assess the utility of providing presets for computed radiography (CR) softcopy display, based not on the window/level settings, but on image processing applied to the image based on optimization for visualization of specific findings, pathologies, etc. Clinical chest images are acquired using an Agfa ADC 70 CR scanner, and transferred over the PACS network to an image processing station which has the capability to perform multiscale contrast equalization. The optimal image processing settings per finding are developed in conjunction with a thoracic radiologist by manipulating the multiscale image contrast amplification algorithm parameters. Softcopy display of images processed with finding-specific settings are compared with the standard default image presentation for fifty cases of each category. Comparison is scored using a five point scale with positive one and two denoting the standard presentation is preferred over the finding-specific presets, negative one and two denoting the finding-specific preset is preferred over the standard presentation, and zero denoting no difference. Presets have been developed for pneumothorax and clinical cases are currently being collected in preparation for formal clinical trials. Subjective assessments indicate a preference for the optimized-preset presentation of images over the standard default, particularly by inexperienced radiology residents and referring clinicians.
Counter-narcotic acoustic buoy (CNAB)
NASA Astrophysics Data System (ADS)
Bailey, Mark E.
2004-09-01
As a means to detect drug trafficking in a maritime environment, the Counter Narcotic Acoustic Buoy is part of an inexpensive system designed to detect "Go Fast" boats and report via satellite to a designated location. A go fast boat for this evaluation is defined as any boat with twin 200 horsepower outboard engines. The buoy is designed for deployment in salt water at depths ranging from 50 to 600 feet and can be easily deployed by one or two persons. Detections are based on noise energy exceeding a preset level within a frequency band associated with the go fast boat's acoustic signature. Detection ranges have been demonstrated to greater than three nautical miles.
Hearing aid malfunction detection system
NASA Technical Reports Server (NTRS)
Kessinger, R. L. (Inventor)
1977-01-01
A malfunction detection system for detecting malfunctions in electrical signal processing circuits is disclosed. Malfunctions of a hearing aid in the form of frequency distortion and/or inadequate amplification by the hearing aid amplifier, as well as weakening of the hearing aid power supply are detectable. A test signal is generated and a timed switching circuit periodically applies the test signal to the input of the hearing aid amplifier in place of the input signal from the microphone. The resulting amplifier output is compared with the input test signal used as a reference signal. The hearing aid battery voltage is also periodically compared to a reference voltage. Deviations from the references beyond preset limits cause a warning system to operate.
Wang, Kai; Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao
2017-10-30
A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1-2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area.
Karplus, H.H.B.; Raptis, A.C.
1981-11-13
A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.
Karplus, Henry H. B.; Raptis, Apostolos C.
1983-01-01
A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.
Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao
2017-01-01
A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1–2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area. PMID:29084157
Post-processing of seismic parameter data based on valid seismic event determination
McEvilly, Thomas V.
1985-01-01
An automated seismic processing system and method are disclosed, including an array of CMOS microprocessors for unattended battery-powered processing of a multi-station network. According to a characterizing feature of the invention, each channel of the network is independently operable to automatically detect, measure times and amplitudes, and compute and fit Fast Fourier transforms (FFT's) for both P- and S- waves on analog seismic data after it has been sampled at a given rate. The measured parameter data from each channel are then reviewed for event validity by a central controlling microprocessor and if determined by preset criteria to constitute a valid event, the parameter data are passed to an analysis computer for calculation of hypocenter location, running b-values, source parameters, event count, P- wave polarities, moment-tensor inversion, and Vp/Vs ratios. The in-field real-time analysis of data maximizes the efficiency of microearthquake surveys allowing flexibility in experimental procedures, with a minimum of traditional labor-intensive postprocessing. A unique consequence of the system is that none of the original data (i.e., the sensor analog output signals) are necessarily saved after computation, but rather, the numerical parameters generated by the automatic analysis are the sole output of the automated seismic processor.
Transient-Switch-Signal Suppressor
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr.
1995-01-01
Circuit delays transmission of switch-opening or switch-closing signal until after preset suppression time. Used to prevent transmission of undesired momentary switch signal. Basic mode of operation simple. Beginning of switch signal initiates timing sequence. If switch signal persists after preset suppression time, circuit transmits switch signal to external circuitry. If switch signal no longer present after suppression time, switch signal deemed transient, and circuit does not pass signal on to external circuitry, as though no transient switch signal. Suppression time preset at value large enough to allow for damping of underlying pressure wave or other mechanical transient.
Cao, Xiaohuang; Zhang, Min; Qian, He; Mujumdar, Arun S
2017-06-01
An online temperature-detection-assisted control system of microwave-assisted pulse-spouted vacuum drying was newly developed. By using this system, temperature control can be automatically and continuously adjusted based on the detection of drying temperature and preset temperature. Various strategies for constant temperature control, linear temperature control and three-step temperature control were applied to drying carrot cubes. Drying kinetics and the quality of various temperature-controlled strategies online are evaluated for the new drying technology as well as its suitability as an alternative drying method. Drying time in 70 °C mode 1 had the shortest drying time and lowest energy consumption in all modes. A suitable colour, highest re-hydration ratio and fracture-hardness, and longest drying time occurred in 30-40-50 °C mode 3. The number of hot spots was reduced in 40-50-60 °C mode 3. Acceptable carrot snacks were obtained in 50-60-70 °C mode 3 and 70 °C mode 2. All temperature curves showed that the actual temperatures followed the preset temperatures appropriately. With this system, a linear temperature-controlled strategy and a three-step temperature-controlled strategy can improve product quality and heating non-uniformity compared to constant temperature control, but need greater energy consumption and longer drying time. A temperature-detection-assisted control system was developed for providing various drying strategies as a suitable alternative in making a snack product. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Han, D. Y.; Cao, P.; Liu, J.; Zhu, J. B.
2017-12-01
Cutter spacing is an essential parameter in the TBM design. However, few efforts have been made to study the optimum cutter spacing incorporating penetration depth. To investigate the influence of pre-set penetration depth and cutter spacing on sandstone breakage and TBM performance, a series of sequential laboratory indentation tests were performed in a biaxial compression state. Effects of parameters including penetration force, penetration depth, chip mass, chip size distribution, groove volume, specific energy and maximum angle of lateral crack were investigated. Results show that the total mass of chips, the groove volume and the observed optimum cutter spacing increase with increasing pre-set penetration depth. It is also found that the total mass of chips could be an alternative means to determine optimum cutter spacing. In addition, analysis of chip size distribution suggests that the mass of large chips is dominated by both cutter spacing and pre-set penetration depth. After fractal dimension analysis, we found that cutter spacing and pre-set penetration depth have negligible influence on the formation of small chips and that small chips are formed due to squeezing of cutters and surface abrasion caused by shear failure. Analysis on specific energy indicates that the observed optimum spacing/penetration ratio is 10 for the sandstone, at which, the specific energy and the maximum angle of lateral cracks are smallest. The findings in this paper contribute to better understanding of the coupled effect of cutter spacing and pre-set penetration depth on TBM performance and rock breakage, and provide some guidelines for cutter arrangement.
NASA Astrophysics Data System (ADS)
Marcus, P. M.; Jona, F.
2005-05-01
A simple effective procedure (MNP) for finding equilibrium tetragonal and hexagonal states under pressure is described and applied. The MNP procedure finds a path to minima of the Gibbs free energy G at T=0 K (G=E+pV, E=energy per atom, p=pressure, V=volume per atom) for tetragonal and hexagonal structures by using the approximate expansion of G in linear and quadratic strains at an arbitrary initial structure to find a change in the strains which moves toward a minimum of G. Iteration automatically proceeds to a minimum within preset convergence criteria on the calculation of the minimum. Comparison is made with experimental results for the ground states of seven metallic elements in hexagonal close-packed (hcp), face- and body-centered cubic structures, and with a previous procedure for finding minima based on tracing G along the epitaxial Bain path (EBP) to a minimum; the MNP is more easily generalized than the EBP procedure to lower symmetry and more atoms in the unit cell. Comparison is also made with a molecular-dynamics program for crystal equilibrium structures under pressure and with CRYSTAL, a program for crystal equilibrium structures at zero pressure. Application of MNP to the elements Y and Cd, which have hcp ground states at zero pressure, finds minima of E at face-centered cubic (fcc) structure for both Y and Cd. Evaluation of all the elastic constants shows that fcc Y is stable, hence a metastable phase, but fcc Cd is unstable.
Method and apparatus for detecting flaws and defects in heat seals
NASA Technical Reports Server (NTRS)
Rai, Kula R. (Inventor); Lew, Thomas M. (Inventor); Sinclair, Robert B. (Inventor)
1993-01-01
Flaws and defects in heat seals formed between sheets of translucent film are identified by optically examining consecutive lateral sections of the seal along the seal length. Each lateral seal section is illuminated and an optical sensor array detects the intensity of light transmitted through the seal section for the purpose of detecting and locating edges in the heat seal. A line profile for each consecutive seal section is derived having an amplitude proportional to the change in light intensity across the seal section. Instances in the derived line profile where the amplitude is greater than a threshold level indicate the detection of a seal edge. The detected edges in each derived line profile are then compared to a preset profile edge standard to identify the existence of a flaw or defect.
Multiscale corner detection and classification using local properties and semantic patterns
NASA Astrophysics Data System (ADS)
Gallo, Giovanni; Giuoco, Alessandro L.
2002-05-01
A new technique to detect, localize and classify corners in digital closed curves is proposed. The technique is based on correct estimation of support regions for each point. We compute multiscale curvature to detect and to localize corners. As a further step, with the aid of some local features, it's possible to classify corners into seven distinct types. Classification is performed using a set of rules, which describe corners according to preset semantic patterns. Compared with existing techniques, the proposed approach inscribes itself into the family of algorithms that try to explain the curve, instead of simple labeling. Moreover, our technique works in manner similar to what is believed are typical mechanisms of human perception.
NASA Astrophysics Data System (ADS)
Dong, Kyung-Rae; Shim, Dong-Oh; Kim, Ho-Sung; Park, Yong-Soon; Chung, Woon-Kwan; Cho, Jae-Hwan
2013-02-01
In a nuclear medicine examination, methods to acquire a static image include the preset count method and the preset time method. The preset count method is used mainly in a static renal scan that utilizes 99 m Tc-DMSA (dimoercaptosuccinic acid) whereas the preset time method is used occasionally. When the preset count method is used, the same number of acquisition counts is acquired for each time, but the scan time varies. When the preset time method is used, the scan time is constant, but the number of counts acquired is not the same. Therefore, this study examined the dependence of the difference in information on the function and the shape of both sides of the kidneys on the counts acquired during a renal scan that utilizes 99 m Tc-DMSA. The study involved patients who had 40-60% relative function of one kidney among patients who underwent a 99 m Tc-DMSA renal scan in the Nuclear Medicine Department during the period from January 11 to March 31, 2012. A gamma camera was used to obtain the acquisition count continuously using 100,000 counts and 300,000 counts, and an acquisition time of 7 minutes (exceeding 300,000 counts). The function and the shape of the kidney were evaluated by measuring the relative function of both sides of the kidneys, the geometric mean, and the size of kidney before comparative analysis. According to the study results, neither the relative function nor the geometric mean of both sides of the kidneys varied significantly with the acquisition count. On the other hand, the size of the kidney tended to be larger with increasing acquisition count.
A 2.4-GHz Energy-Efficient Transmitter for Wireless Medical Applications.
Qi Zhang; Peng Feng; Zhiqing Geng; Xiaozhou Yan; Nanjian Wu
2011-02-01
A 2.4-GHz energy-efficient transmitter (TX) for wireless medical applications is presented in this paper. It consists of four blocks: a phase-locked loop (PLL) synthesizer with a direct frequency presetting technique, a class-B power amplifier, a digital processor, and nonvolatile memory (NVM). The frequency presetting technique can accurately preset the carrier frequency of the voltage-controlled oscillator and reduce the lock-in time of the PLL synthesizer, further increasing the data rate of communication with low power consumption. The digital processor automatically compensates preset frequency variation with process, voltage, and temperature. The NVM stores the presetting signals and calibration data so that the TX can avoid the repetitive calibration process and save the energy in practical applications. The design is implemented in 0.18- μm radio-frequency complementary metal-oxide semiconductor process and the active area is 1.3 mm (2). The TX achieves 0-dBm output power with a maximum data rate of 4 Mb/s/2 Mb/s and dissipates 2.7-mA/5.4-mA current from a 1.8-V power supply for on-off keying/frequency-shift keying modulation, respectively. The corresponding energy efficiency is 1.2 nJ/b·mW and 4.8 nJ/b· mW when normalized to the transmitting power.
Method for detection and correction of errors in speech pitch period estimates
NASA Technical Reports Server (NTRS)
Bhaskar, Udaya (Inventor)
1989-01-01
A method of detecting and correcting received values of a pitch period estimate of a speech signal for use in a speech coder or the like. An average is calculated of the nonzero values of received pitch period estimate since the previous reset. If a current pitch period estimate is within a range of 0.75 to 1.25 times the average, it is assumed correct, while if not, a correction process is carried out. If correction is required successively for more than a preset number of times, which will most likely occur when the speaker changes, the average is discarded and a new average calculated.
36. View of preset counter (PC) console and tracking console ...
36. View of preset counter (PC) console and tracking console on right, located in MWOC facility in transmitter building no. 102. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
Control of mechanical systems by the mixed "time and expenditure" criterion
NASA Astrophysics Data System (ADS)
Alesova, I. M.; Babadzanjanz, L. K.; Pototskaya, I. Yu.; Pupysheva, Yu. Yu.; Saakyan, A. T.
2018-05-01
The optimal controlled motion of a mechanical system, that is determined by the linear system ODE with constant coefficients and piecewise constant control components, is considered. The number of control switching points and the heights of control steps are considered as preset. The optimized functional is combination of classical time criteria and "Expenditure criteria", that is equal to the total area of all steps of all control components. In the absence of control, the solution of the system is equal to the sum of components (frequency components) corresponding to different eigenvalues of the matrix of the ODE system. Admissible controls are those that turn to zero (at a non predetermined time moment) the previously chosen frequency components of the solution. An algorithm for the finding of control switching points, based on the necessary minimum conditions for mixed criteria, is proposed.
Pang, Peter C; Lam, Carly S; Woo, George C
2010-09-01
This study aims to determine the factors affecting the accuracy in the Developmental Eye Movement (DEM) test measurement for Cantonese-speaking children. The voices of 10 Cantonese-speaking children (aged between six and eight years) undertaking the vertical test (40 numbers) of the DEM test were recorded on a digital audio recorder. These voice clips were assessed by an experienced examiner to give the DEM test times. The examiner repeated the measurement five times for each voice clip and completed all 10 voice clips from the 10 children. The average of a single measurement, the mean of two, the mean of three and the mean of five repeated measurements were then compared. Five experienced and five inexperienced examiners of the DEM test were asked to record the results from five Cantonese-speaking children by listening to the playback of prerecorded audio clips. The deviation of the results from the preset values between the two groups was compared. There is no difference between the single measurement and those obtained by mean of two, three, four or five. Both experienced and inexperienced examiners obtained a higher deviation from the preset values in the adjusted compared with the non-adjusted times in both vertical and horizontal times. Experienced examiners measured the vertical times and adjusted vertical times significantly closer to the preset values than the inexperienced examiners (paired t-test, p < 0.05). The DEM test needs to be measured only once for an accurate time measurement. Inaccurate assessment of 'reading errors' in the DEM test can increase the inaccuracy of the adjusted times. It is suggested that an audio recording of the test be made to allow reassessment of reading errors. Experience in using the DEM test yields a more accurate DEM measurement as errors are detected more easily.
Kaeding, T S
2015-06-01
Research in the field of whole body vibration (WBV) training and the use of it in practice might be hindered by the fact that WBV training devices generate and transmit frequencies and/or modes of vibration which are different to preset adjustments. This research project shall clarify how exact WBV devices apply the by manufacturer information promised preset frequency and mode of vibration. Nine professional devices for WBV training were tested by means of a tri-axial accelerometer. The accelerations of each device were recorded under different settings with a tri-axial accelerometer. Beneath the measurement of different combinations of preset frequency and amplitude the repeatability across 3 successive measurements with the same preset conditions and one measurement under loaded condition were carried out. With 3 exceptions (both Board 3000 & srt medical PRO) we did not find noteworthy divergences between preset and actual applied frequencies. In these 3 devices we found divergences near -25%. Loading the devices did not affect the applied frequency or mode of vibration. There were no important divergences measurable for the applied frequency and mode of vibration regarding repeatability. The results of our measurements cannot be generalized as we only measured one respectively at most two devices of one model in terms of a random sample. Based on these results we strongly recommend that user in practice and research should analyse their WBV training devices regarding applied frequency and mode of vibration.
Delwel, Ernst J; de Jong, Dirk A; Dammers, Ruben; Kurt, Erkan; van den Brink, Wimar; Dirven, Clemens M F
2013-07-01
In treating idiopathic normal pressure hydrocephalus (INPH) with a shunt there is always a risk of underdrainage or overdrainage. The hypothesis is tested whether patients treated using an adjustable valve preset at the highest opening pressure leads to comparable good clinical results with less subdural effusions than in a control group with an opening pressure preset at a low pressure level. A multicentre prospective randomised trial was performed on a total of 58 patients suspected of INPH. Thirty patients were assigned to (control) group 1 and received a Strata shunt (Medtronic, Goleta, USA) with the valve preset at a performance level (PL) of 1.0, while 28 patients were assigned to group 2 and received a Strata shunt with the valve preset at PL 2.5. In this group the PL was allowed to be lowered until improvement or radiological signs of overdrainage were met. Significantly more subdural effusions were observed in the improved patients of group 1. There was no statistically significant difference in improvement between both groups overall. On the basis of this multicentre prospective randomised trial it is to be recommended to treat patients with INPH with a shunt with an adjustable valve, preset at the highest opening pressure and lowered until clinical improvement or radiological signs of overdrainage occur although slower improvement and more shunt adjustments might be the consequence.
Comparison of design and torque measurements of various manual wrenches.
Neugebauer, Jörg; Petermöller, Simone; Scheer, Martin; Happe, Arndt; Faber, Franz-Josef; Zoeller, Joachim E
2015-01-01
Accurate torque application and determination of the applied torque during surgical and prosthetic treatment is important to reduce complications. A study was performed to determine and compare the accuracy of manual wrenches, which are available in different designs with a large range of preset torques. Thirteen different wrench systems with a variety of preset torques ranging from 10 to 75 Ncm were evaluated. Three different designs were available, with a spring-in-coil or toggle design as an active mechanism or a beam as a passive mechanism, to select the preset torque. To provide a clinically relevant analysis, a total of 1,170 torque measurements in the range of 10 to 45 Ncm were made in vitro using an electronic torque measurement device. The absolute deviations in Ncm and percent deviations across all wrenches were small, with a mean of -0.24 ± 2.15 Ncm and -0.84% ± 11.72% as a shortfall relative to the preset value. The greatest overage was 8.2 Ncm (82.5%), and the greatest shortfall was 8.47 Ncm (46%). However, extreme values were rare, with 95th-percentile values of -1.5% (lower value) and -0.16% (upper value). A comparison with respect to wrench design revealed significantly higher deviations for coil and toggle-style wrenches than for beam wrenches. Beam wrenches were associated with a lower risk of rare extreme values thanks to their passive mechanism of achieving the selected preset torque, which minimizes the risk of harming screw connections.
Fast, Low-Power, Hysteretic Level-Detector Circuit
NASA Technical Reports Server (NTRS)
Arditti, Mordechai
1993-01-01
Circuit for detection of preset levels of voltage or current intended to replace standard fast voltage comparator. Hysteretic analog/digital level detector operates at unusually low power with little sacrifice of speed. Comprises low-power analog circuit and complementary metal oxide/semiconductor (CMOS) digital circuit connected in overall closed feedback loop to decrease rise and fall times, provide hysteresis, and trip-level control. Contains multiple subloops combining linear and digital feedback. Levels of sensed signals and hysteresis level easily adjusted by selection of components to suit specific application.
Pressure Switch Is a Low Cost Battery Indicator
NASA Technical Reports Server (NTRS)
Abita, J. L.
1982-01-01
Conventional pressure switch, fabricated by printed-circuit manufacturing techniques, can indicate when charge on battery departs from preset level. Membrane on switch is exposed to internal pressure of battery, which varies according to stored charge. When pressure varies from preset level, switch can turn on a light-emitting diode or similar indicator to warn user that battery is low.
76 FR 46352 - Approval of Noise Compatibility Program for San Diego International, San Diego, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-02
... use of monitoring equipment for enforcement purposes by in-situ measurement of any pre-set noise... by in-situ measurement of any pre-set noise thresholds.); Revise the Noise Exposure Map was approved... Authority under Part 150 were in compliance with applicable requirements. On June 30, 2011, the FAA approved...
Electronic strain-level counter
NASA Technical Reports Server (NTRS)
Pitts, F. L.; Spencer, J. L. (Inventor)
1973-01-01
An electronic strain level counter for obtaining structural strain data on in-flight aircraft is described. The device counts the number of times the strain at a point on an aircraft structural member exceeds each of several preset levels. A dead band is provided at each level to prohibit the counting of small strain variations around a given preset level.
Spool-Valve Pressure-Difference Regulator
NASA Technical Reports Server (NTRS)
Grasso, A. P.
1983-01-01
Valves maintain preset pressure difference between gas flows. Two spool valves connected by shaft move back and forth in response to changes in pressure in oxygen and hydrogen chambers. Spool-valve assembly acts to restore pressures to preset difference. By eliminating diaphragms, pressure exerted directly on external end of spool valve; however, forces and therefore sensitivity of assembly are reduced.
Opinion evolution influenced by informed agents
NASA Astrophysics Data System (ADS)
Fan, Kangqi; Pedrycz, Witold
2016-11-01
Guiding public opinions toward a pre-set target by informed agents can be a strategy adopted in some practical applications. The informed agents are common agents who are employed or chosen to spread the pre-set opinion. In this work, we propose a social judgment based opinion (SJBO) dynamics model to explore the opinion evolution under the influence of informed agents. The SJBO model distinguishes between inner opinions and observable choices, and incorporates both the compromise between similar opinions and the repulsion between dissimilar opinions. Three choices (support, opposition, and remaining undecided) are considered in the SJBO model. Using the SJBO model, both the inner opinions and the observable choices can be tracked during the opinion evolution process. The simulation results indicate that if the exchanges of inner opinions among agents are not available, the effect of informed agents is mainly dependent on the characteristics of regular agents, including the assimilation threshold, decay threshold, and initial opinions. Increasing the assimilation threshold and decay threshold can improve the guiding effectiveness of informed agents. Moreover, if the initial opinions of regular agents are close to null, the full and unanimous consensus at the pre-set opinion can be realized, indicating that, to maximize the influence of informed agents, the guidance should be started when regular agents have little knowledge about a subject under consideration. If the regular agents have had clear opinions, the full and unanimous consensus at the pre-set opinion cannot be achieved. However, the introduction of informed agents can make the majority of agents choose the pre-set opinion.
Method of Making Lightweight, Single Crystal Mirror
NASA Technical Reports Server (NTRS)
Bly, Vincent T. (Inventor)
2015-01-01
A method of making a mirror from a single crystal blank may include fine grinding top and bottom surfaces of the blank to be parallel. The blank may then be heat treated to near its melting temperature. An optical surface may be created on an optical side of the blank. A protector may be bonded to the optical surface. With the protector in place, the blank may be light weighted by grinding a non-optical surface of the blank using computer controlled grinding. The light weighting may include creating a structure having a substantially minimum mass necessary to maintain distortion of the mirror within a preset limit. A damaged layer of the non-optical surface caused by light weighting may be removed with an isotropic etch and/or repaired by heat treatment. If an oxide layer is present, the entire blank may then be etched using, for example, hydrofluoric acid. A reflecting coating may be deposited on the optical surface.
Zhang, Lian; Wang, Zhi; Shi, Chengyu; Long, Tengfei; Xu, X George
2018-05-30
Deformable image registration (DIR) is the key process for contour propagation and dose accumulation in adaptive radiation therapy (ART). However, currently, ART suffers from a lack of understanding of "robustness" of the process involving the image contour based on DIR and subsequent dose variations caused by algorithm itself and the presetting parameters. The purpose of this research is to evaluate the DIR caused variations for contour propagation and dose accumulation during ART using the RayStation treatment planning system. Ten head and neck cancer patients were selected for retrospective studies. Contours were performed by a single radiation oncologist and new treatment plans were generated on the weekly CT scans for all patients. For each DIR process, four deformation vector fields (DVFs) were generated to propagate contours and accumulate weekly dose by the following algorithms: (a) ANACONDA with simple presetting parameters, (b) ANACONDA with detailed presetting parameters, (c) MORFEUS with simple presetting parameters, and (d) MORFEUS with detailed presetting parameters. The geometric evaluation considered DICE coefficient and Hausdorff distance. The dosimetric evaluation included D 95 , D max , D mean , D min , and Homogeneity Index. For geometric evaluation, the DICE coefficient variations of the GTV were found to be 0.78 ± 0.11, 0.96 ± 0.02, 0.64 ± 0.15, and 0.91 ± 0.03 for simple ANACONDA, detailed ANACONDA, simple MORFEUS, and detailed MORFEUS, respectively. For dosimetric evaluation, the corresponding Homogeneity Index variations were found to be 0.137 ± 0.115, 0.006 ± 0.032, 0.197 ± 0.096, and 0.006 ± 0.033, respectively. The coherent geometric and dosimetric variations also consisted in large organs and small organs. Overall, the results demonstrated that the contour propagation and dose accumulation in clinical ART were influenced by the DIR algorithm, and to a greater extent by the presetting parameters. A quality assurance procedure should be established for the proper use of a commercial DIR for adaptive radiation therapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
MULTICHANNEL PULSE-HEIGHT ANALYZER
Russell, J.T.; Lefevre, H.W.
1958-01-21
This patent deals with electronic computing circuits and more particularly to pulse-height analyzers used for classifying variable amplitude pulses into groups of different amplitudes. The device accomplishes this pulse allocation by by converting the pulses into frequencies corresponding to the amplitudes of the pulses, which frequencies are filtered in channels individually pretuned to a particular frequency and then detected and recorded in the responsive channel. This circuit substantially overcomes the disadvantages of prior annlyzers incorporating discriminators pre-set to respond to certain voltage levels, since small variation in component values is not as critical to satisfactory circuit operation.
A coloured oil level indicator detection method based on simple linear iterative clustering
NASA Astrophysics Data System (ADS)
Liu, Tianli; Li, Dongsong; Jiao, Zhiming; Liang, Tao; Zhou, Hao; Yang, Guoqing
2017-12-01
A detection method of coloured oil level indicator is put forward. The method is applied to inspection robot in substation, which realized the automatic inspection and recognition of oil level indicator. Firstly, the detected image of the oil level indicator is collected, and the detected image is clustered and segmented to obtain the label matrix of the image. Secondly, the detection image is processed by colour space transformation, and the feature matrix of the image is obtained. Finally, the label matrix and feature matrix are used to locate and segment the detected image, and the upper edge of the recognized region is obtained. If the upper limb line exceeds the preset oil level threshold, the alarm will alert the station staff. Through the above-mentioned image processing, the inspection robot can independently recognize the oil level of the oil level indicator, and instead of manual inspection. It embodies the automatic and intelligent level of unattended operation.
Electrochemically controlled charging circuit for storage batteries
Onstott, E.I.
1980-06-24
An electrochemically controlled charging circuit for charging storage batteries is disclosed. The embodiments disclosed utilize dc amplification of battery control current to minimize total energy expended for charging storage batteries to a preset voltage level. The circuits allow for selection of Zener diodes having a wide range of reference voltage levels. Also, the preset voltage level to which the storage batteries are charged can be varied over a wide range.
Martin, A.D.
1986-05-09
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay provides a first output signal at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits latch the high resolution data to form a first synchronizing data set. A selected time interval has been preset to internal counters and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses count down the counters to generate an internal pulse delayed by an internal which is functionally related to the preset time interval. A second LCD corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD to generate a second set of synchronizing data which is complementary with the first set of synchronizing data for presentation to logic circuits. The logic circuits further delay the internal output signal with the internal pulses. The final delayed output signal thereafter enables the output pulse generator to produce the desired output pulse at the preset time delay interval following input of the trigger pulse.
A reference architecture for telemonitoring.
Clarke, Malcolm
2004-01-01
The Telecare Interactive Continuous Monitoring System exploits GPRS to provide an ambulatory device that monitors selected vital signs on a continuous basis. Alarms are sent when parameters fall outside preset limits, and accompanying physiological data may also be transmitted. The always-connected property of GPRS allows continuous interactive control of the device and its sensors, permitting changes to monitoring parameters or even enabling continuous monitoring of a sensor in emergency. A new personal area network (PAN) has been developed to support short-range wireless connection to sensors worn on the body including ECG and finger worn SpO2. Most notable is use of ultra low radio frequency to reduce power to minimum. The system has been designed to use a hierarchical architecture for sensors and "derived" signals, such as HR from ECG, so that each can be independently controlled and managed. Sensors are treated as objects, and functions are defined to control aspects of behaviour. These are refined in order to define a generic set of abstract functions to handle the majority of functions, leaving a minimum of sensor specific commands. The intention is to define a reference architecture in order to research the functionality and system architecture of a telemonitoring system. The Telecare project is funded through a grant from the European Commission (IST programme).
Development and psychometric properties of the Ethics Environment Questionnaire.
McDaniel, C
1997-09-01
The author reports on the development and the psychometric properties of the Ethics Environment Questionnaire (EEQ), an instrument by which to measure the opinions of health-care providers about ethics in their clinical practice organizations. The EEQ was developed to increase the number of valid and reliable measures pertaining to ethics in health-care delivery. The EEQ is a 20-item self-administered questionnaire using a Likert-type 5-point format, offering ease of administration. It is applicable to a cross-section of health-care practitioners and health-care facilities. The mean administration time is 10 minutes. The EEQ represents testing on 450 respondents in acute care settings among a cross-section of acute care facilities. Internal consistency reliability using Cronbach's alpha coefficient is 0.93, and the test-retest reliability is 0.88. Construct, content, and criterion validity are established. The scale is unidimensional, with factor loadings exceeding the minimum preset criterion. Mean score is 3.1 out of 5.0, with scores of 3.5 and above interpreted as reflective of a positive ethics environment. The EEQ provides a measure of ethics in health-care organizations among multi-practitioners in clinical practice on a valid, reliable, cost effective, and easily administered instrument that requires minimum investment of personnel time.
Apparatus and method for detecting tampering in flexible structures
Maxey, Lonnie C [Knoxville, TN; Haynes, Howard D [Knoxville, TN
2011-02-01
A system for monitoring or detecting tampering in a flexible structure includes taking electrical measurements on a sensing cable coupled to the structure, performing spectral analysis on the measured data, and comparing the spectral characteristics of the event to those of known benign and/or known suspicious events. A threshold or trigger value may used to identify an event of interest and initiate data collection. Alternatively, the system may be triggered at preset intervals, triggered manually, or triggered by a signal from another sensing device such as a motion detector. The system may be used to monitor electrical cables and conduits, hoses and flexible ducts, fences and other perimeter control devices, structural cables, flexible fabrics, and other flexible structures.
Metering System for Compressible Fluids.
1995-04-10
pressure switch and a low pass pressure switch are included in 5 line with the compressible fluid cylinder; consequently, the density of the...Once the pressure in first container 30 reaches the preset pressure for pressure switch 58, inlet valves 20 and 24 are closed and outlet valves 36...is allowed to drop to the preset pressure for pressure switch 60, at which time outlet valves 36 and 40 are closed, inlet valves 20 and 24 are
Indexing Mount For Rotation Of Optical Component
NASA Technical Reports Server (NTRS)
Reichle, Donald J., Jr.; Barnes, Norman P.
1993-01-01
Indexing mount for polarizer, wave plate, birefringent plate, or other optical component facilitates rotation of component to one or more preset angles. Includes hexagonal nut holding polarizer or other optical component. Ball bearing loaded by screw engages notch on cylindrical extension of nut engaging bracket. Time-consuming and tedious angular adjustment unnecessary: component turned quickly and easily, by hand or by use of wrench, to preset angular positions maintained by simple ball-detent mechanism.
Feng, Jingwen; Lin, Jie; Zhang, Pengquan; Yang, Songnan; Sa, Yu; Feng, Yuanming
2017-08-29
High-content screening is commonly used in studies of the DNA damage response. The double-strand break (DSB) is one of the most harmful types of DNA damage lesions. The conventional method used to quantify DSBs is γH2AX foci counting, which requires manual adjustment and preset parameters and is usually regarded as imprecise, time-consuming, poorly reproducible, and inaccurate. Therefore, a robust automatic alternative method is highly desired. In this manuscript, we present a new method for quantifying DSBs which involves automatic image cropping, automatic foci-segmentation and fluorescent intensity measurement. Furthermore, an additional function was added for standardizing the measurement of DSB response inhibition based on co-localization analysis. We tested the method with a well-known inhibitor of DSB response. The new method requires only one preset parameter, which effectively minimizes operator-dependent variations. Compared with conventional methods, the new method detected a higher percentage difference of foci formation between different cells, which can improve measurement accuracy. The effects of the inhibitor on DSB response were successfully quantified with the new method (p = 0.000). The advantages of this method in terms of reliability, automation and simplicity show its potential in quantitative fluorescence imaging studies and high-content screening for compounds and factors involved in DSB response.
Modro, S. Michael; Ougouag, Abderrafi M.
2005-09-20
A passively actuated valve for isolating a high pressure zone from a low pressure zone and discontinuing the isolation when the pressure in the high pressure zone drops below a preset threshold. If the pressure in the high pressure zone drops below the preset threshold, the valve opens and allows flow from the high pressure zone to the low pressure zone. The valve remains open allowing pressure equalization and back-flow should a pressure inversion between the two pressure zone occur.
Alternative stitching method for massively parallel e-beam lithography
NASA Astrophysics Data System (ADS)
Brandt, Pieter; Tranquillin, Céline; Wieland, Marco; Bayle, Sébastien; Milléquant, Matthieu; Renault, Guillaume
2015-03-01
In this study a novel stitching method other than Soft Edge (SE) and Smart Boundary (SB) is introduced and benchmarked against SE. The method is based on locally enhanced Exposure Latitude without cost of throughput, making use of the fact that the two beams that pass through the stitching region can deposit up to 2x the nominal dose. The method requires a complex Proximity Effect Correction that takes a preset stitching dose profile into account. On a Metal clip at minimum half-pitch of 32 nm for MAPPER FLX 1200 tool specifications, the novel stitching method effectively mitigates Beam to Beam (B2B) position errors such that they do not induce increase in CD Uniformity (CDU). In other words, the same CDU can be realized inside the stitching region as outside the stitching region. For the SE method, the CDU inside is 0.3 nm higher than outside the stitching region. 5 nm direct overlay impact from B2B position errors cannot be reduced by a stitching strategy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aziz, Mohd Khairul Bazli Mohd, E-mail: mkbazli@yahoo.com; Yusof, Fadhilah, E-mail: fadhilahy@utm.my; Daud, Zalina Mohd, E-mail: zalina@ic.utm.my
Recently, many rainfall network design techniques have been developed, discussed and compared by many researchers. Present day hydrological studies require higher levels of accuracy from collected data. In numerous basins, the rain gauge stations are located without clear scientific understanding. In this study, an attempt is made to redesign rain gauge network for Johor, Malaysia in order to meet the required level of accuracy preset by rainfall data users. The existing network of 84 rain gauges in Johor is optimized and redesigned into a new locations by using rainfall, humidity, solar radiation, temperature and wind speed data collected during themore » monsoon season (November - February) of 1975 until 2008. This study used the combination of geostatistics method (variance-reduction method) and simulated annealing as the algorithm of optimization during the redesigned proses. The result shows that the new rain gauge location provides minimum value of estimated variance. This shows that the combination of geostatistics method (variance-reduction method) and simulated annealing is successful in the development of the new optimum rain gauge system.« less
High resolution digital delay timer
Martin, Albert D.
1988-01-01
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay (20) provides a first output signal (24) at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits (26, 28) latch the high resolution data (24) to form a first synchronizing data set (60). A selected time interval has been preset to internal counters (142, 146, 154) and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses (32, 34) count down the counters to generate an internal pulse delayed by an interval which is functionally related to the preset time interval. A second LCD (184) corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD (74) to generate a second set of synchronizing data (76) which is complementary with the first set of synchronizing data (60) for presentation to logic circuits (64). The logic circuits (64) further delay the internal output signal (72) to obtain a proper phase relationship of an output signal (80) with the internal pulses (32, 34). The final delayed output signal (80) thereafter enables the output pulse generator (82) to produce the desired output pulse (84) at the preset time delay interval following input of the trigger pulse (10, 12).
NASA Astrophysics Data System (ADS)
Starostin, A. A.; Shangin, V. V.; Bukhman, V. G.; Volosnikov, D. V.; Skripov, P. V.
2016-08-01
The research is devoted to development of a self-contained device for rapid detection of volatile impurities in the oil system of a turbine and testing it using the operating equipment. The device consists of a remote sensor, whose sensitive element is a 3-5-mm long wire probe 20 microns in diameter, and a measurement unit that comprises a microcontroller with a set of peripherals. The design of the device enables automation of the measurement procedure with a minimum number of preset settings and real-time output of information to the operator console. The software of the device provides two-stage pulse heating of the wire probe and a resistance temperature detector. The two-stage mode proves to be the most sensitive to appearance in the system of moisture, including its trace amounts. The characteristic time of the heating is of the order of 10 ms. The measurement procedure is based on a method that consists in automatic search for spontaneous boiling-up temperature of the oil accompanied by a characteristic response signal. The results were interpreted by formal correlation of the measured values with an array of calibration data obtained in similar experiments with well-defined oil samples. An experimental method for application of the device has been developed that takes into account technological factors, such as comparatively high values of the flow rate and the temperature of the oil in locations of the oil drain from bearings, the variability of these values, and the variety of noise types that accompany the operation of the thermal power equipment that complicate the online measurements. Tests of the device were carried out in locations of oil drain from supporting bearings. The test results have demonstrated the possibility of applying the device directly in the oil system of a turbine and provided a practical basis for development of a system of multipoint control of the technological scheme in real time.
System and method for tracking a signal source. [employing feedback control
NASA Technical Reports Server (NTRS)
Mogavero, L. N.; Johnson, E. G.; Evans, J. M., Jr.; Albus, J. S. (Inventor)
1978-01-01
A system for tracking moving signal sources is disclosed which is particularly adaptable for use in tracking stage performers. A miniature transmitter is attached to the person or object to be tracked and emits a detectable signal of a predetermined frequency. A plurality of detectors positioned in a preset pattern sense the signal and supply output information to a phase detector which applies signals representing the angular orientation of the transmitter to a computer. The computer provides command signals to a servo network which drives a device such as a motor driven mirror reflecting the beam of a spotlight, to track the moving transmitter.
Method and apparatus for monitoring oxygen partial pressure in air masks
NASA Technical Reports Server (NTRS)
Kelly, Mark E. (Inventor); Pettit, Donald R. (Inventor)
2006-01-01
Method and apparatus are disclosed for monitoring an oxygen partial pressure in an air mask and providing a tactile warning to the user. The oxygen partial pressure in the air mask is detected using an electrochemical sensor, the output signal from which is provided to a comparator. The comparator compares the output signal with a preset reference value or range of values representing acceptable oxygen partial pressures. If the output signal is different than the reference value or outside the range of values, the air mask is vibrated by a vibrating motor to alert the user to a potentially hypoxic condition.
Autonomous navigation method for substation inspection robot based on travelling deviation
NASA Astrophysics Data System (ADS)
Yang, Guoqing; Xu, Wei; Li, Jian; Fu, Chongguang; Zhou, Hao; Zhang, Chuanyou; Shao, Guangting
2017-06-01
A new method of edge detection is proposed in substation environment, which can realize the autonomous navigation of the substation inspection robot. First of all, the road image and information are obtained by using an image acquisition device. Secondly, the noise in the region of interest which is selected in the road image, is removed with the digital image processing algorithm, the road edge is extracted by Canny operator, and the road boundaries are extracted by Hough transform. Finally, the distance between the robot and the left and the right boundaries is calculated, and the travelling distance is obtained. The robot's walking route is controlled according to the travel deviation and the preset threshold. Experimental results show that the proposed method can detect the road area in real time, and the algorithm has high accuracy and stable performance.
Telesmanich, Morgan E; Jensen, Corey T; Enriquez, Jose L; Wagner-Bartak, Nicolaus A; Liu, Xinming; Le, Ott; Wei, Wei; Chandler, Adam G; Tamm, Eric P
2017-08-01
To qualitatively and quantitatively compare abdominal CT images reconstructed with a newversion of model-based iterative reconstruction (Veo 3.0; GE Healthcare Waukesha, WI) utilizing varied presetsof resolution preference, noise reduction and slice optimization. This retrospective study was approved by our Institutional Review Board and was Health Insurance Portability and Accountability Act compliant. The raw datafrom 30 consecutive patients who had undergone CT abdomen scanning were used to reconstructfour clinical presets of 3.75mm axial images using Veo 3.0: 5% resolution preference (RP05n), 5%noise reduction (NR05) and 40% noise reduction (NR40) with new 3.75mm "sliceoptimization," as well as one set using RP05 with conventional 0.625mm "slice optimization" (RP05c). The images were reviewed by two independent readers in a blinded, randomized manner using a 5-point Likert scale as well as a 5-point comparative scale. Multiple two-dimensional circular regions of interest were defined for noise and contrast-to-noise ratio measurements. Line profiles were drawn across the 7 lp cm -1 bar pattern of the Catphan 600 phantom for evaluation of spatial resolution. The NR05 image set was ranked as the best series in overall image quality (mean difference inrank 0.48, 95% CI [0.081-0.88], p = 0.01) and with specific reference to liver evaluation (meandifference 0.46, 95% CI [0.030-0.89], p = 0.03), when compared with the secondbest series ineach category. RP05n was ranked as the best for bone evaluation. NR40 was ranked assignificantly inferior across all assessed categories. Although the NR05 and RP05c image setshad nearly the same contrast-to-noise ratio and spatial resolution, NR05 was generally preferred. Image noise and spatial resolution increased along a spectrum with RP05n the highest and NR40the lowest. Compared to RP05n, the average noise was 21.01% lower for NR05, 26.88%lower for RP05c and 50.86% lower for NR40. Veo 3.0 clinical presets allow for selection of image noise and spatial resolution balance; for contrast-enhanced CT evaluation of the abdomen, the 5% noise reduction preset with 3.75 mm slice optimization (NR05) was generally ranked superior qualitatively and, relative to other series, was in the middle of the spectrum with reference to image noise and spatial resolution. Advances in knowledge: To our knowledge, this is the first study of Veo 3.0 noise reduction presets and varied slice optimization. This study provides insight into the behaviour of slice optimization and documents the degree of noise reduction and spatial resolution changes that users can expect across various Veo 3.0 clinical presets. These results provide important parameters to guide preset selection for both clinical and research purposes.
ERIC Educational Resources Information Center
Dong, Nianbo; Maynard, Rebecca
2013-01-01
This paper and the accompanying tool are intended to complement existing supports for conducting power analysis tools by offering a tool based on the framework of Minimum Detectable Effect Sizes (MDES) formulae that can be used in determining sample size requirements and in estimating minimum detectable effect sizes for a range of individual- and…
Colucci, E; Clark, A; Lang, C E; Pomeroy, V M
2017-12-01
Dose-optimisation studies as precursors to clinical trials are rare in stroke rehabilitation. To develop a rule-based, dose-finding design for stroke rehabilitation research. 3+3 rule-based, dose-finding study. Dose escalation/de-escalation was undertaken according to preset rules and a mathematical sequence (modified Fibonacci sequence). The target starting daily dose was 50 repetitions for the first cohort. Adherence was recorded by an electronic counter. At the end of the 2-week training period, the adherence record indicated dose tolerability (adherence to target dose) and the outcome measure indicated dose benefit (10% increase in motor function). The preset increment/decrease and checking rules were then applied to set the dose for the subsequent cohort. The process was repeated until preset stopping rules were met. Participants had a mean age of 68 (range 48 to 81) years, and were a mean of 70 (range 9 to 289) months post stroke with moderate upper limb paresis. A custom-built model of exercise-based training to enhance ability to open the paretic hand. Repetitions per minute of extension/flexion of paretic digits against resistance. Usability of the preset rules and whether the maximally tolerated dose was identifiable. Five cohorts of three participants were involved. Discernibly different doses were set for each subsequent cohort (i.e. 50, 100, 167, 251 and 209 repetitions/day). The maximally tolerated dose for the model training task was 209 repetitions/day. This dose-finding design is a feasible method for use in stroke rehabilitation research. Copyright © 2017 Chartered Society of Physiotherapy. All rights reserved.
Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo
2017-04-01
Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.
P.S. Homann; B.T. Bormann; J.R. Boyle; R.L. Darbyshire; R. Bigley
2008-01-01
Detecting changes in forest soil C and N is vital to the study of global budgets and long-term ecosystem productivity. Identifying differences among land-use practices may guide future management. Our objective was to determine the relation of minimum detectable changes (MDCs) and minimum detectable differences between treatments (MDDs) to soil C and N variability at...
A Manual Control Test for the Detection and Deterrence of Impaired Drivers
NASA Technical Reports Server (NTRS)
Stein, A. C.; Allen, R. W.; Jex, H. R.
1984-01-01
A brief manual control test and a decision strategy were developed, laboratory tested, and field validated which provide a means for detecting human operator impairment from alcohol or other drugs. The test requires the operator to stabilize progressively unstable controlled element dynamics. Control theory and experimental data verify that the human operator's control ability on this task is constrained by basic cybernetic characteristics, and that task performance is reliably affected by impairment effects on these characteristics. Assessment of human operator control ability is determined by a statistically based decision strategy. The operator is allowed several chances to exceed a preset pass criterion. Procedures are described for setting the pass criterion based on individual ability and a desired unimpaired failure rate. These procedures were field tested with apparatus installed in automobiles that were designed to discourage drunk drivers from operating their vehicles. This test program demonstrated that the control task and detection strategy could be applied in a practical setting to screen human operators for impairment in their basic cybernetic skills.
Ekberg, Peter; Su, Rong; Chang, Ernest W.; Yun, Seok Hyun; Mattsson, Lars
2014-01-01
Optical coherence tomography (OCT) is useful for materials defect analysis and inspection with the additional possibility of quantitative dimensional metrology. Here, we present an automated image-processing algorithm for OCT analysis of roll-to-roll multilayers in 3D manufacturing of advanced ceramics. It has the advantage of avoiding filtering and preset modeling, and will, thus, introduce a simplification. The algorithm is validated for its capability of measuring the thickness of ceramic layers, extracting the boundaries of embedded features with irregular shapes, and detecting the geometric deformations. The accuracy of the algorithm is very high, and the reliability is better than 1 µm when evaluating with the OCT images using the same gauge block step height reference. The method may be suitable for industrial applications to the rapid inspection of manufactured samples with high accuracy and robustness. PMID:24562018
Calibrated vapor generator source
Davies, John P.; Larson, Ronald A.; Goodrich, Lorenzo D.; Hall, Harold J.; Stoddard, Billy D.; Davis, Sean G.; Kaser, Timothy G.; Conrad, Frank J.
1995-01-01
A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet.
Effects of changing climate on reference crop evapotranspiration over 1961-2013 in Xinjiang, China
NASA Astrophysics Data System (ADS)
Yao, Ning; Li, Yi; Sun, Changfeng
2018-01-01
To know the importance of different climate variables on reference crop evapotranspiration ( ET o), a step-by-step sensitivity analysis of ET o to single, two, and multi-climate variables ( C) was conducted. ET o in north, south, and entire Xinjiang Province, China, over 1961-2013 was estimated using the Penman-Monteith equation. Trends in the involved six Cs (i.e., minimum temperature— T min, average temperature— T ave, maximum temperature— T max, wind speed at 2 m— U 2, sunshine hour— n, and relative humidity— RH) were detected by the modified Mann-Kendall test. Nineteen scenarios of changed Cs were preset to obtain recalculated ET o values considering the actual trend in each C and the Pearson's correlation relationship between ET o and Cs. The results showed that ET o was mostly sensitive to T max, U 2, and n. Sensitivity of ET o to the two overlapped changes of T min and T max caused larger increases in ET o than T max and T ave, T ave and T max, T max and (- n), T max and RH, T max and (- U 2), and T min and T ave, but the overlapped changes (- U 2) and (- n) caused larger decreases in ET o than the other two C scenarios. The simultaneously increased T max, T min, T ave, and RH plus decreased U 2 and n had caused the actual decreases in ET o in Xinjiang. In general, the effects of decreased U 2 and n on decreasing ET o compensated the effects of increased T max on decreasing ET o in Xinjiang.
The wide-range ejector flowmeter: calibrated gas evacuation comprising both high and low gas flows.
Waaben, J; Brinkløv, M M; Jørgensen, S
1984-11-01
The wide-range ejector flowmeter is an active scavenging system applying calibrated gas removal directly to the anaesthetic circuit. The evacuation rate can be adjusted on the flowmeter under visual control using the calibration scale ranging from 200 ml X min-1 to 151 X min-1. The accuracy of the calibration was tested on three ejector flowmeters at 12 different presettings. The percentage deviation from presetting varied from + 18 to - 19.4 per cent. The ejector flowmeter enables the provision of consistent and accurately calibrated extraction of waste gases and is applicable within a wide range of fresh gas flows.
Development and Assessment of a New CFRP Rod Anchor System for Prestressed Concrete
NASA Astrophysics Data System (ADS)
Al-Mayah, A.; Soudki, K.; Plumtree, A.
2006-09-01
Design concepts and experimental assessment of a new wedge anchor system for prestressing CFRP rods are presented. This compact and reusable anchor consists of an outer cylinder (barrel), a number of wedges, and a soft metal sleeve. The contacting surfaces of the wedges and barrel have a circular profile along the length of the anchor. Tensile testing using different presetting loads, geometric configurations, and rod sizes was carried out. The relationship of the tensile load and displacement of the rod was established. Presetting was found unnecessary since the anchor system was found to be capable of carrying the full design strength of the rods.
Pre-set extrusion bioprinting for multiscale heterogeneous tissue structure fabrication.
Kang, Donggu; Ahn, Geunseon; Kim, Donghwan; Kang, Hyun-Wook; Yun, Seokhwan; Yun, Won-Soo; Shim, Jin-Hyung; Jin, Songwan
2018-06-06
Recent advances in three-dimensional bioprinting technology have led to various attempts in fabricating human tissue-like structures. However, current bioprinting technologies have limitations for creating native tissue-like structures. To resolve these issues, we developed a new pre-set extrusion bioprinting technique that can create heterogeneous, multicellular, and multimaterial structures simultaneously. The key to this ability lies in the use of a precursor cartridge that can stably preserve a multimaterial with a pre-defined configuration that can be simply embedded in a syringe-based printer head. The multimaterial can be printed and miniaturized through a micro-nozzle without conspicuous deformation according to the pre-defined configuration of the precursor cartridge. Using this system, we fabricated heterogeneous tissue-like structures such as spinal cords, hepatic lobule, blood vessels, and capillaries. We further obtained a heterogeneous patterned model that embeds HepG2 cells with endothelial cells in a hepatic lobule-like structure. In comparison with homogeneous and heterogeneous cell printing, the heterogeneous patterned model showed a well-organized hepatic lobule structure and higher enzyme activity of CYP3A4. Therefore, this pre-set extrusion bioprinting method could be widely used in the fabrication of a variety of artificial and functional tissues or organs.
NASA Astrophysics Data System (ADS)
Batzias, Dimitris F.; Karvounis, Sotirios
2012-12-01
Technology transfer may take place in parallel with cooperative action between companies participating in the same organizational scheme or using one another as subcontractor (outsourcing). In this case, cooperation should be realized by means of Standard Methods and Recommended Practices (SRPs) to achieve (i) quality of intermediate/final products according to specifications and (ii) industrial process control as required to guarantee such quality with minimum deviation (corresponding to maximum reliability) from preset mean values of representative quality parameters. This work deals with the design of the network of SRPs needed in each case for successful cooperation, implying also the corresponding technology transfer, effectuated through a methodological framework developed in the form of an algorithmic procedure with 20 activity stages and 8 decision nodes. The functionality of this methodology is proved by presenting the path leading from (and relating) a standard test method for toluene, as petrochemical feedstock in the toluene diisocyanate production, to the (6 generations distance upstream) performance evaluation of industrial process control systems (ie., from ASTM D5606 to BS EN 61003-1:2004 in the SRPs network).
Presetting ECG electrodes for earlier heart rate detection in the delivery room.
Gulati, Rashmi; Zayek, Michael; Eyal, Fabien
2018-07-01
To determine whether heart rate (HR) could be detected earlier than by pulse oximeter (POX), using a novel method of application of electrocardiogram (ECG) electrodes during neonatal resuscitation in the delivery room. ECG electrodes were set before delivery to be applied to the back of infants' thorax. Time to detect HR was recorded as soon as a numerical HR along with a recognizable and persistent QRS complex was observed on ECG monitor (HRECG) and a plethysmographic waveform was seen on POX monitor (HRPOX). Out of 334 infants, 49 were <31 weeks of gestational age. Overall, the median (interquartile range, IQR) time to detect HRECG was significantly shorter [29 (5, 60) seconds] than time by POX [60 (45,120) seconds], (p < 0.001). Similarly, in <31-week infants, the median (IQR) time to detect HRECG was 10 (2, 40) seconds compared to 60 (30,120) seconds by POX, (p < 0.001). Failure to have HR detected by 1 minute occurred in 30%, 54% and 20% of infants by ECG, POX and either of the devices, respectively. In the delivery room, electrodes applied by the study method are more effective than pulse oximetry in providing the neonatal team with timely HR information that is necessary for proper resuscitative actions. Published by Elsevier B.V.
Automation for Crushing and Screening Equipment to Produce Graded Paving Crushed Stone
NASA Astrophysics Data System (ADS)
Tikhonov, Anatoly; Velichkin, Vladimir
2017-10-01
This paper offers analysis of factors related to production and storage of graded crushed stone, which adversely impact the service life and wear resistance of asphalt-concrete motor road pavements. The paper describes external and technology-related parameters that may cause changes of the preset ratio in graded crushed stone. Control factors are described that ensure the formulated fraction ratio in crushed stone by controlling the operation mode of the crushing and screening equipment. The paper also contains an ACS flow chart for crushing and screening equipment engaged in continuous closed-cycle two-stage technology. Performance of the ACS to maintain the preset fractionated crushed stone ratio has been confirmed with a mathematical model.
Jefferson, S.
1958-01-28
This patent relates to a device normally termed a godevil for use in clearing pipes of sludge, and in particular describes an arrangement for housing a radioactive source within a go-devil whereby the source is removed from a radioactivity shield for detection purposes only when the go-devil is in use. In the described go-devil the radioactive source is housed in a member attached to a piston. Under normal pressure conditions the piston is forced in a direction to position the source within a lead shield. A bellows senses the pressure external to the go-devil and acts through a hydraulic line to force the piston in a direction to remove the source from the shield as long as the pressure is above a pre-set value.
Calibrated vapor generator source
Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.
1995-09-26
A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.
Investigation of Dynamic Crack Coalescence Using a Gypsum-Like 3D Printing Material
NASA Astrophysics Data System (ADS)
Jiang, Chao; Zhao, Gao-Feng; Zhu, Jianbo; Zhao, Yi-Xin; Shen, Luming
2016-10-01
Dynamic crack coalescence attracts great attention in rock mechanics. However, specimen preparation in experimental study is a time-consuming and difficult procedure. In this work, a gypsum-like material by powder bed and inkjet 3D printing technique was applied to produce specimens with preset cracks for split Hopkinson pressure bar (SHPB) test. From micro X-ray CT test, it was found that the 3D printing technique could successfully prepare specimens that contain preset cracks with width of 0.2 mm. Basic mechanical properties of the 3D printing material, i.e., the elastic modulus, the Poisson's ratio, the density, the compressive strength, the indirect tensile strength, and the fracture toughness, were obtained and reported. Unlike 3D printed specimens using polylactic acid, these gypsum-like specimens can produce failure patterns much closer to those observed in classical rock mechanical tests. Finally, the dynamic crack coalescence of the 3D printed specimens with preset cracks were captured using a high-speed camera during SHPB tests. Failure patterns of these 3D printed specimens are similar to the specimens made by Portland cement concrete. Our results indicate that sample preparation by 3D printing is highly competitive due to its quickness in prototyping, precision and flexibility on the geometry, and high material homogeneity.
Field Tests of a Tractor Rollover Detection and Emergency Notification System.
Liu, B; Koc, A B
2015-04-01
The objective of this research was to assess the feasibility of a rollover detection and emergency notification system for farm tractors using field tests. The emergency notification system was developed based on a tractor stability model and implemented on a mobile electronic device with the iOS operating system. A complementary filter was implemented to combine the data from the accelerometer and gyroscope sensors to improve their accuracies in calculating the roll and pitch angles and the roll and pitch rates. The system estimates a stability index value during tractor operation, displays feedback messages when the stability index is lower than a preset threshold value, and transmits emergency notification messages when an overturn happens. Ten tractor rollover tests were conducted on a field track. The developed system successfully monitored the stability of the tractor during all of the tests. The iOS application was able to detect rollover accidents and transmit emergency notifications in the form of a phone call and email when an accident was detected. The system can be a useful tool for training and education in safe tractor operation. The system also has potential for stability monitoring and emergency notification of other on-road and off-road motorized vehicles.
A method to perform spinal motion analysis from functional X-ray images.
Schulze, Martin; Trautwein, Frank; Vordemvenne, Thomas; Raschke, Michael; Heuer, Frank
2011-06-03
Identifying spinal instability is an important aim for proper surgical treatment. Analysis of functional X-ray images delivers measurements of the range of motion (RoM) and the center of rotation (CoR). In today's practice, CoR determination is often omitted, due to the lack of accurate methods. The aim of this work was to investigate the accuracy of a new analysis software (FXA™) based on an in vitro experiment. Six bovine spinal specimens (L3-4) were mounted in a robot (KR125, Kuka). CoRs were predefined by locking the robot actuator tool center point to the estimated position of the physiologic CoR and taking a baseline X-ray. Specimens were deflected to various RoM(preset) flexion/extension angles about the CoR(preset). Lateral functional radiographs were acquired and specimen movements were recorded using an optical motion tracking system (Optotrak Certus). RoM and CoR errors were calculated from presets for both methods. Prior to the experiment, the FXA™ software was verified with artificially generated images. For the artificial images, FXA™ yielded a mean RoM-error of 0.01 ± 0.03° (bias ± standard deviation). In the experiment, RoM-error of the FXA™-software (deviation from presets) was 0.04 ± 0.13°, and 0.10 ± 0.16° for the Optotrak, respectively. Both correlated with 0.998 (p < 0.001). For RoM < 1.0°, FXA™ determined CoR positions with a bias>20mm. This bias progressively decreased from RoM = 1° (bias = 6.0mm) to RoM = 9° (bias<1.5mm). Under the assumption that CoR location variances <5mm are clinically irrelevant on the lumbar spine, the FXA™ method can accurately determine CoRs for RoMs > 1°. Utilizing FXA™, polysegmental RoMs, CoRs and implant migration measurements could be performed in daily practice. Copyright © 2011 Elsevier Ltd. All rights reserved.
Silver-silver sulfate reference electrodes for use in lead-acid batteries
NASA Astrophysics Data System (ADS)
Ruetschi, Paul
Electrochemical properties of silver-silver sulfate reference electrodes for lead-acid batteries are described, and the following possible applications discussed: Determination of individual capacities of positive and negative plates. Monitoring individual electrode behavior during deep discharge and cell reversal. Optimization charge or discharge parameters, by controlling the current such that pre-determined limits of positive or negative half-cell potential are respected. Observation of acid concentration differences, for example due to acid stratification, by measuring diffusion potentials (concentration-cell voltages). Detection of defective cells, and defective plate sets, in a string of cells, at the end of their service life. Silver-silver sulfate reference electrodes, permanently installed in lead-acid cells, may be a means to improve battery management, and therewith to improve reliability and service life. In vented batteries, reference electrodes may be used to limit positive plate polarization during charge, or float-charge. Limiting the positive half-cell potential to an upper, pre-set value would permit to keep anodic corrosion as low as possible. During cycling, discharge could be terminated when the half-cell potential of the positive electrode has dropped to a pre-set limit. This would prevent excessive discharge of the positive electrodes, which could result in an improvement of cycle life. In valve-regulated batteries, reference electrodes may be used to adjust float-charge conditions such as to assure sufficient cathodic polarization of the negative electrodes, in order to avoid sulfation. The use of such reference electrodes could be beneficial particularly in multi-cell batteries, with overall voltages above 12 V, operated in a partial-state-of-charge.
NASA Technical Reports Server (NTRS)
Zangemeister, Wolfgang H.
1989-01-01
Normal subjects are able to change voluntarily and continuously their head-eye latency together with their compensatory eye movement gain. A continuous spectrum of intent-latency modes of the subject's coordinated gaze through verbal feedback could be demonstrated. It was also demonstrated that the intent to counteract any perturbation of head-eye movement, i.e., the mental set, permitted the subjects to manipulate consciously their vestibular ocular reflex (VOR) gain. From the data, it is inferred that the VOR is always on. It may be, however, variably suppressed by higher cortical control. With appropriate training, head-mounted displays should permit an easy VOR presetting that leads to image stabilization, perhaps together with a decrease of possible misjudgements.
NASA Astrophysics Data System (ADS)
Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao
2018-02-01
A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.
Wu, Jin-Gen; Liu, Man-Chi; Tsai, Ming-Fei; Yu, Wei-Shun; Chen, Jian-Zhang; Cheng, I-Chun; Lin, Pei-Chun
2012-04-01
We demonstrate a novel, vertical temperature-mapping incubator utilizing eight layers of thermoelectric (TE) modules mounted around a test tube. The temperature at each layer of the TE module is individually controlled to simulate the vertical temperature profile of geo-temperature variations with depth. Owing to the constraint of non-intrusion to the filled geo-samples, the temperature on the tube wall is adopted for measurement feedback. The design considerations for the incubator include spatial arrangement of the energy transfer mechanism, heating capacity of the TE modules, minimum required sample amount for follow-up instrumental or chemical analysis, and the constraint of non-intrusion to the geo-samples during incubation. The performance of the incubator is experimentally evaluated with two tube conditions and under four preset temperature profiles. Test tubes are either empty or filled with quartz sand, which has comparable thermal properties to the materials in the geo-environment. The applied temperature profiles include uniform, constant temperature gradient, monotonic-increasing parabolic, and parabolic. The temperature on the tube wall can be controlled between 20 °C and 90 °C with an averaged root mean squared error of 1 °C. © 2012 American Institute of Physics
Alternative stitching method for massively parallel e-beam lithography
NASA Astrophysics Data System (ADS)
Brandt, Pieter; Tranquillin, Céline; Wieland, Marco; Bayle, Sébastien; Milléquant, Matthieu; Renault, Guillaume
2015-07-01
In this study, a stitching method other than soft edge (SE) and smart boundary (SB) is introduced and benchmarked against SE. The method is based on locally enhanced exposure latitude without throughput cost, making use of the fact that the two beams that pass through the stitching region can deposit up to 2× the nominal dose. The method requires a complex proximity effect correction that takes a preset stitching dose profile into account. Although the principle of the presented stitching method can be multibeam (lithography) systems in general, in this study, the MAPPER FLX 1200 tool is specifically considered. For the latter tool at a metal clip at minimum half-pitch of 32 nm, the stitching method effectively mitigates beam-to-beam (B2B) position errors such that they do not induce an increase in critical dimension uniformity (CDU). In other words, the same CDU can be realized inside the stitching region as outside the stitching region. For the SE method, the CDU inside is 0.3 nm higher than outside the stitching region. A 5-nm direct overlay impact from the B2B position errors cannot be reduced by a stitching strategy.
Retrieval dynamics in self-terminated memory search.
Hussey, Erika K; Dougherty, Michael R; Harbison, J Isaiah; Davelaar, Eddy J
2014-02-01
Most free-recall experiments employ a paradigm in which participants are given a preset amount of time to retrieve items from a list. While much has been learned using this paradigm, it ignores an important component of many real-world retrieval tasks: the decision to terminate memory search. The present study examines the temporal characteristics underlying memory search by comparing within subjects a standard retrieval paradigm with a finite, preset amount of time (closed interval) to a design that allows participants to terminate memory search on their own (open interval). Calling on the results of several presented simulations, we anticipated that the threshold for number of retrieval failures varied as a function of the nature of the recall paradigm, such that open intervals should result in lower thresholds than closed intervals. Moreover, this effect was expected to manifest in interretrieval times (IRTs). Although retrieval-interval type did not significantly impact the number of items recalled or error rates, IRTs were sensitive to the manipulation. Specifically, the final IRTs in the closed-interval paradigm were longer than those of the open-interval paradigm. This pattern suggests that providing participants with a preset retrieval interval not only masks an important component of the retrieval process (the memory search termination decision), but also alters temporal retrieval dynamics. Task demands may compel people to strategically control aspects of their retrieval by implementing different stopping rules.
Green supply chain: Simulating road traffic congestion
NASA Astrophysics Data System (ADS)
Jalal, Muhammad Zulqarnain Hakim Abd; Nawawi, Mohd Kamal Mohd; Laailatul Hanim Mat Desa, Wan; Khalid, Ruzelan; Khalid Abduljabbar, Waleed; Ramli, Razamin
2017-09-01
With the increasing awareness of the consumers about environmental issues, businesses, households and governments increasingly want use green products and services which lead to green supply chain. This paper discusses a simulation study of a selected road traffic system that will contribute to the air pollution if in the congestion state. Road traffic congestion (RTC) can be caused by a temporary obstruction, a permanent capacity bottleneck in the network itself, and stochastic fluctuation in demand within a particular sector of the network, leading to spillback and queue propagation. A discrete-event simulation model is developed to represent the real traffic light control (TLC) system condition during peak hours. Certain performance measures such as average waiting time and queue length were measured using the simulation model. Existing system uses pre-set cycle time to control the light changes which is fixed time cycle. In this research, we test several other combination of pre-set cycle time with the objective to find the best system. In addition, we plan to use a combination of the pre-set cycle time and a proximity sensor which have the authority to manipulate the cycle time of the lights. The sensors work in such situation when the street seems to have less occupied vehicles, obviously it may not need a normal cycle for green light, and automatically change the cycle to street where vehicle is present.
An adaptive Kalman filter technique for context-aware heart rate monitoring.
Xu, Min; Goldfain, Albert; Dellostritto, Jim; Iyengar, Satish
2012-01-01
Traditional physiological monitoring systems convert a person's vital sign waveforms, such as heart rate, respiration rate and blood pressure, into meaningful information by comparing the instant reading with a preset threshold or a baseline without considering the contextual information of the person. It would be beneficial to incorporate the contextual data such as activity status of the person to the physiological data in order to obtain a more accurate representation of a person's physiological status. In this paper, we proposed an algorithm based on adaptive Kalman filter that describes the heart rate response with respect to different activity levels. It is towards our final goal of intelligent detection of any abnormality in the person's vital signs. Experimental results are provided to demonstrate the feasibility of the algorithm.
Neutron multiplicity counting: Confidence intervals for reconstruction parameters
Verbeke, Jerome M.
2016-03-09
From nuclear materials accountability to homeland security, the need for improved nuclear material detection, assay, and authentication has grown over the past decades. Starting in the 1940s, neutron multiplicity counting techniques have enabled quantitative evaluation of masses and multiplications of fissile materials. In this paper, we propose a new method to compute uncertainties on these parameters using a model-based sequential Bayesian processor, resulting in credible regions in the fissile material mass and multiplication space. These uncertainties will enable us to evaluate quantitatively proposed improvements to the theoretical fission chain model. Additionally, because the processor can calculate uncertainties in real time,more » it is a useful tool in applications such as portal monitoring: monitoring can stop as soon as a preset confidence of non-threat is reached.« less
Real-time stereo vision-based lane detection system
NASA Astrophysics Data System (ADS)
Fan, Rui; Dahnoun, Naim
2018-07-01
The detection of multiple curved lane markings on a non-flat road surface is still a challenging task for vehicular systems. To make an improvement, depth information can be used to enhance the robustness of the lane detection systems. In this paper, a proposed lane detection system is developed from our previous work where the estimation of the dense vanishing point is further improved using the disparity information. However, the outliers in the least squares fitting severely affect the accuracy when estimating the vanishing point. Therefore, in this paper we use random sample consensus to update the parameters of the road model iteratively until the percentage of the inliers exceeds our pre-set threshold. This significantly helps the system to overcome some suddenly changing conditions. Furthermore, we propose a novel lane position validation approach which computes the energy of each possible solution and selects all satisfying lane positions for visualisation. The proposed system is implemented on a heterogeneous system which consists of an Intel Core i7-4720HQ CPU and an NVIDIA GTX 970M GPU. A processing speed of 143 fps has been achieved, which is over 38 times faster than our previous work. Moreover, in order to evaluate the detection precision, we tested 2495 frames including 5361 lanes. It is shown that the overall successful detection rate is increased from 98.7% to 99.5%.
The advantages of cost plus award fee contracts
NASA Technical Reports Server (NTRS)
Keathley, William C.
1994-01-01
A Cost Plus Award Fee contract is the best procurement vehicle for the high-tech, one-of-a-kind, development projects that constitute most of NASA'S projects. The use of this type of contract requires more government and contractor effort than any other forms of contracts. An award fee contract is described as an arrangement whereby the government periodically awards a fee consistent with the cost, schedule and technical performance that is achieved by a contractor during a preset period with preset award fee pools. It's the only contracting method where both the government and contractor goals are closely linked. It also has a built-in mechanism to conveniently alter and emphasize program events in order to current external and internal situations. The award fee process also demands good communication between government and contractor participants.
Fail-over file transfer process
NASA Technical Reports Server (NTRS)
Semancik, Susan K. (Inventor); Conger, Annette M. (Inventor)
2005-01-01
The present invention provides a fail-over file transfer process to handle data file transfer when the transfer is unsuccessful in order to avoid unnecessary network congestion and enhance reliability in an automated data file transfer system. If a file cannot be delivered after attempting to send the file to a receiver up to a preset number of times, and the receiver has indicated the availability of other backup receiving locations, then the file delivery is automatically attempted to one of the backup receiving locations up to the preset number of times. Failure of the file transfer to one of the backup receiving locations results in a failure notification being sent to the receiver, and the receiver may retrieve the file from the location indicated in the failure notification when ready.
Self-adaptive demodulation for polarization extinction ratio in distributed polarization coupling.
Zhang, Hongxia; Ren, Yaguang; Liu, Tiegen; Jia, Dagong; Zhang, Yimo
2013-06-20
A self-adaptive method for distributed polarization extinction ratio (PER) demodulation is demonstrated. It is characterized by dynamic PER threshold coupling intensity (TCI) and nonuniform PER iteration step length (ISL). Based on the preset PER calculation accuracy and original distribution coupling intensity, TCI and ISL can be made self-adaptive to determine contributing coupling points inside the polarizing devices. Distributed PER is calculated by accumulating those coupling points automatically and selectively. Two different kinds of polarization-maintaining fibers are tested, and PERs are obtained after merely 3-5 iterations using the proposed method. Comparison experiments with Thorlabs commercial instrument are also conducted, and results show high consistency. In addition, the optimum preset PER calculation accuracy of 0.05 dB is obtained through many repeated experiments.
TUKAN—An 8K Pulse Height Analyzer and Multi-Channel Scaler With a PCI or a USB Interface
NASA Astrophysics Data System (ADS)
Guzik, Z.; Borsuk, S.; Traczyk, K.; Plominski, M.
2006-02-01
In this paper we present two types of 8K-channel analyzers designed for spectroscopy and intensity versus time measurements. The first type (Tukan-8K-PCI) incorporates a PCI interface and is designed to be plugged into a PCI slot of a normal PC. The second type (Tukan-8K-USB) incorporates a USB interface. It is mounted in a separate screened box and can be powered either directly from the USB port or from an external dc source (wall adapter or battery). Each type of device may operate in either of two independent operational modes: Multi Channel Analysis (MCA) and Multi-Channel Scaling (MCS). The most crucial component for the MCA mode-the Peak Detect and Hold circuit-is featuring a novel architecture based on a diamond transistor. Its analog stage can accept analog pulses with rise times as short as 100 ns and has a differential linearity below 1% with sliding scale averaging over the full scale. The functionality includes automatic stop on a programmable count in the Region-Of-Interest (ROI) and on preset live- or real time. The MCS mode works at medium counting rates of up to 8 MHz. The dwell time, the number of channels and single or multi-sweep mode may be preset. Each of these parameters can also be controlled externally via four user configurable logical I/O lines. A single Altera FLEX 10KE30 FPGA provides all control functions and incorporates PCI interface. The USB interface is based on FTDI FIFO controller. Advanced and user-friendly software has been developed for the analyzer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Wenzhong; Yi, Ji; Chen, Siyu
Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (smallmore » ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.« less
Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F.
2015-01-01
Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length. PMID:26328984
Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F
2015-09-01
Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature. By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.
Khedr, Maan; El-Sheimy, Nasser
2017-01-01
The growing market of smart devices make them appealing for various applications. Motion tracking can be achieved using such devices, and is important for various applications such as navigation, search and rescue, health monitoring, and quality of life-style assessment. Step detection is a crucial task that affects the accuracy and quality of such applications. In this paper, a new step detection technique is proposed, which can be used for step counting and activity monitoring for health applications as well as part of a Pedestrian Dead Reckoning (PDR) system. Inertial and Magnetic sensors measurements are analyzed and fused for detecting steps under varying step modes and device pose combinations using a free-moving handheld device (smartphone). Unlike most of the state of the art research in the field, the proposed technique does not require a classifier, and adaptively tunes the filters and thresholds used without the need for presets while accomplishing the task in a real-time operation manner. Testing shows that the proposed technique successfully detects steps under varying motion speeds and device use cases with an average performance of 99.6%, and outperforms some of the state of the art techniques that rely on classifiers and commercial wristband products. PMID:29117143
Finding-specific display presets for computed radiography soft-copy reading.
Andriole, K P; Gould, R G; Webb, W R
1999-05-01
Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding-specific processing is preferred over the standard presentation, and zero denoting no difference. Processing settings have been developed for several findings including pneumothorax and lung nodules, and clinical cases are currently being collected in preparation for formal clinical trials. Preliminary results indicate a preference for the optimized-processing presentation of images over the standard default, particularly by inexperienced radiology residents and referring clinicians.
Liu, X; Dingley, J; Elstad, M; Scull-Brown, E; Steen, P A; Thoresen, M
2013-05-01
Neuroprotection from therapeutic hypothermia increases when combined with the anaesthetic gas xenon in animal studies. A clinical feasibility study of the combined treatment has been successfully undertaken in asphyxiated human term newborns. It is unknown whether xenon alone would be sufficient for sedation during hypothermia eliminating or reducing the need for other sedative or analgesic infusions in ventilated sick infants. Minimum alveolar concentration (MAC) of xenon is unknown in any neonatal species. Eight newborn pigs were anaesthetised with sevoflurane alone and then sevoflurane plus xenon at two temperatures. Pigs were randomised to start at either 38.5°C or 33.5°C. MAC for sevoflurane was determined using the claw clamp technique at the preset body temperature. For xenon MAC determination, a background of 0.5 MAC sevoflurane was used, and 60% xenon added to the gas mixture. The relationship between sevoflurane and xenon MAC is assumed to be additive. Xenon concentrations were changed in 5% steps until a positive clamp reaction was noted. Pigs' temperature was changed to the second target, and two MAC determinations for sevoflurane and 0.5 MAC sevoflurane plus xenon were repeated. MAC for sevoflurane was 4.1% [95% confidence interval (CI): 3.65-4.50] at 38.5°C and 3.05% (CI: 2.63-3.48) at 33.5°C, a significant reduction. MAC for xenon was 120% at 38.5°C and 116% at 33.5°C, not different. In newborn swine sevoflurane, MAC was temperature dependent, while xenon MAC was independent of temperature. There was large individual variability in xenon MAC, from 60% to 120%. © 2013 The Acta Anaesthesiologica Scandinavica Foundation.
Minimum Detectable Dose as a Measure of Bioassay Programme Capability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.
2003-01-01
This paper suggests that minimum detectable dose (MDD) be used to describe the capability of bioassay programs for which intakes are expected to be rare. This allows expression of the capability in units that correspond directly to primary dose limits. The concept uses the well-established analytical statistic minimum detectable amount (MDA) as the starting point and assumes MDA detection at a prescribed time post intake. The resulting dose can then be used as an indication of the adequacy or capability of the program for demonstrating compliance with the performance criteria. MDDs can be readily tabulated or plotted to demonstrate themore » effectiveness of different types of monitoring programs. The inclusion of cost factors for bioassay measurements can allow optimisation.« less
Minimum detectable dose as a measure of bioassay programme capability.
Carbaugh, E H
2003-01-01
This paper suggests that minimum detectable dose (MDD) be used to describe the capability of bioassay programmes for which intakes are expected to be rare. This allows expression of the capability in units that correspond directly to primary dose limits. The concept uses the well established analytical statistic minimum detectable amount (MDA) as the starting point, and assumes MDA detection at a prescribed time post-intake. The resulting dose can then be used as an indication of the adequacy or capability of the programme for demonstrating compliance with the performance criteria. MDDs can be readily tabulated or plotted to demonstrate the effectiveness of different types of monitoring programmes. The inclusion of cost factors for bioassay measurements can allow optimisation.
Dual current readout for precision plating
NASA Technical Reports Server (NTRS)
Iceland, W. F.
1970-01-01
Bistable amplifier prevents damage in the low range circuitry of a dual scale ammeter. It senses the current and switches automatically to the high range circuitry as the current rises above a preset level.
A minimax technique for time-domain design of preset digital equalizers using linear programming
NASA Technical Reports Server (NTRS)
Vaughn, G. L.; Houts, R. C.
1975-01-01
A linear programming technique is presented for the design of a preset finite-impulse response (FIR) digital filter to equalize the intersymbol interference (ISI) present in a baseband channel with known impulse response. A minimax technique is used which minimizes the maximum absolute error between the actual received waveform and a specified raised-cosine waveform. Transversal and frequency-sampling FIR digital filters are compared as to the accuracy of the approximation, the resultant ISI and the transmitted energy required. The transversal designs typically have slightly better waveform accuracy for a given distortion; however, the frequency-sampling equalizer uses fewer multipliers and requires less transmitted energy. A restricted transversal design is shown to use the least number of multipliers at the cost of a significant increase in energy and loss of waveform accuracy at the receiver.
Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo
2015-11-01
There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
A customizable commercial miniaturized 320×256 indium gallium arsenide shortwave infrared camera
NASA Astrophysics Data System (ADS)
Huang, Shih-Che; O'Grady, Matthew; Groppe, Joseph V.; Ettenberg, Martin H.; Brubaker, Robert M.
2004-10-01
The design and performance of a commercial short-wave-infrared (SWIR) InGaAs microcamera engine is presented. The 0.9-to-1.7 micron SWIR imaging system consists of a room-temperature-TEC-stabilized, 320x256 (25 μm pitch) InGaAs focal plane array (FPA) and a high-performance, highly customizable image-processing set of electronics. The detectivity, D*, of the system is greater than 1013 cm-√Hz/W at 1.55 μm, and this sensitivity may be adjusted in real-time over 100 dB. It features snapshot-mode integration with a minimum exposure time of 130 μs. The digital video processor provides real time pixel-to-pixel, 2-point dark-current subtraction and non-uniformity compensation along with defective-pixel substitution. Other features include automatic gain control (AGC), gamma correction, 7 preset configurations, adjustable exposure time, external triggering, and windowing. The windowing feature is highly flexible; the region of interest (ROI) may be placed anywhere on the imager and can be varied at will. Windowing allows for high-speed readout enabling such applications as target acquisition and tracking; for example, a 32x32 ROI window may be read out at over 3500 frames per second (fps). Output video is provided as EIA170-compatible analog, or as 12-bit CameraLink-compatible digital. All the above features are accomplished in a small volume < 28 cm3, weight < 70 g, and with low power consumption < 1.3 W at room temperature using this new microcamera engine. Video processing is based on a field-programmable gate array (FPGA) platform with a soft-embedded processor that allows for ease of integration/addition of customer-specific algorithms, processes, or design requirements. The camera was developed with the high-performance, space-restricted, power-conscious application in mind, such as robotic or UAV deployment.
Zhao, Wei; Tang, Zhenmin; Yang, Yuwang; Wang, Lei; Lan, Shaohua
2014-01-01
This paper presents a searching control approach for cooperating mobile sensor networks. We use a density function to represent the frequency of distress signals issued by victims. The mobile nodes' moving in mission space is similar to the behaviors of fish-swarm in water. So, we take the mobile node as artificial fish node and define its operations by a probabilistic model over a limited range. A fish-swarm based algorithm is designed requiring local information at each fish node and maximizing the joint detection probabilities of distress signals. Optimization of formation is also considered for the searching control approach and is optimized by fish-swarm algorithm. Simulation results include two schemes: preset route and random walks, and it is showed that the control scheme has adaptive and effective properties. PMID:24741341
Zhao, Wei; Tang, Zhenmin; Yang, Yuwang; Wang, Lei; Lan, Shaohua
2014-01-01
This paper presents a searching control approach for cooperating mobile sensor networks. We use a density function to represent the frequency of distress signals issued by victims. The mobile nodes' moving in mission space is similar to the behaviors of fish-swarm in water. So, we take the mobile node as artificial fish node and define its operations by a probabilistic model over a limited range. A fish-swarm based algorithm is designed requiring local information at each fish node and maximizing the joint detection probabilities of distress signals. Optimization of formation is also considered for the searching control approach and is optimized by fish-swarm algorithm. Simulation results include two schemes: preset route and random walks, and it is showed that the control scheme has adaptive and effective properties.
Measurement of visual contrast sensitivity
NASA Astrophysics Data System (ADS)
Vongierke, H. E.; Marko, A. R.
1985-04-01
This invention involves measurement of the visual contrast sensitivity (modulation transfer) function of a human subject by means of linear or circular spatial frequency pattern on a cathode ray tube whose contrast is automatically decreasing or increasing depending on the subject pressing or releasing a hand-switch button. The threshold of detection of the pattern modulation is found by the subject by adjusting the contrast to values which vary about the subject's threshold thereby determining the threshold and also providing by the magnitude of the contrast fluctuations between reversals some estimate of the variability of the subject's absolute threshold. The invention also involves the slow automatic sweeping of the spatial frequency of the pattern over the spatial frequencies after preset time intervals or after threshold has been defined at each frequency by a selected number of subject-determined threshold crossings; i.e., contrast reversals.
Apparatus for safeguarding a radiological source
Bzorgi, Fariborz M
2014-10-07
A tamper detector is provided for safeguarding a radiological source that is moved into and out of a storage location through an access porthole for storage and use. The radiological source is presumed to have an associated shipping container approved by the U.S. Nuclear Regulatory Commission for transporting the radiological source. The tamper detector typically includes a network of sealed tubing that spans at least a portion of the access porthole. There is an opening in the network of sealed tubing that is large enough for passage therethrough of the radiological source and small enough to prevent passage therethrough of the associated shipping cask. Generally a gas source connector is provided for establishing a gas pressure in the network of sealed tubing, and a pressure drop sensor is provided for detecting a drop in the gas pressure below a preset value.
NASA Technical Reports Server (NTRS)
Fern, Lisa Carolynn
2017-01-01
The primary activity for the UAS-NAS Human Systems Integration (HSI) sub-project in Phase 1 was support of RTCA Special Committee 228 Minimum Operational Performance Standards (MOPS). We provide data on the effect of various Detect and Avoid (DAA) display features with respect to pilot performance of the remain well clear function in order to determine the minimum requirements for DAA displays.
Guidelines for review and evaluation of backcalculation results
DOT National Transportation Integrated Search
2006-02-01
This document presets a new approach to determining layered elastic moduli from in situ load-deflection data, which was developed under the Federal Highway Administration's project for reviewing Long-Term Pavement Performance (LTPP) backcalculation d...
Electronic drop sensing in microfluidic devices: automated operation of a nanoliter viscometer
Srivastava, Nimisha; Burns, Mark A.
2007-01-01
We describe three droplet sensing techniques: a digital electrode, an analog electrode, and a thermal method. All three techniques use a single layer of metal lines that is easy to microfabricate and an electronic signal can be produced using low DC voltages. While the electrode methods utilize changes in electrical conductivity when the air/liquid interface of the droplet passes over a pair of electrodes, the thermal method is based on convective heat loss from a locally heated region. For the electrode method, the analog technique is able to detect 25 nL droplets while the digital technique is capable of detecting droplets as small as 100 pL. For thermal sensing, temperature profiles in the range of 36 °C and higher were used. Finally, we have used the digital electrode method and an array of electrodes located at preset distances to automate the operation of a previously described microfluidic viscometer. The viscometer is completely controlled by a laptop computer, and the total time for operation including setup, calibration, sample addition and viscosity calculation is approximately 4 minutes. PMID:16738725
Spatiotemporal activity patterns detected from single cell measurements from behaving animals
NASA Astrophysics Data System (ADS)
Villa, Alessandro E. P.; Tetko, Igor V.
1999-03-01
Precise temporal patterning of activity within and between neurons has been predicted on theoretical grounds, and found in the spike trains of neurons recorded from anesthetized and conscious animals, in association with sensor stimuli and particular phases of task performance. However, the functional significance of such patterning in the generation of behavior has not been confirmed. We recorded from multiple single neurons in regions of rat auditory cortex during the waiting period of a Go/NoGo task. During this time the animal waited for an auditory signal with high cognitive load. Of note is the fact that neural activity during the period analyzed was essentially stationary, with no event related variability in firing. Detected patterns therefore provide a measure of brain state that could not be addressed by standard methods relying on analysis of changes in mean discharge rate. The possibility is discussed that some patterns might reflect a preset bias to a particular response, formed in the waiting period. Others patterns might reflect a state of prior preparation of appropriate neural assemblies for analyzing a signal that is expected but of unknown behavioral valence.
Rotor damage detection by using piezoelectric impedance
NASA Astrophysics Data System (ADS)
Qin, Y.; Tao, Y.; Mao, Y. F.
2016-04-01
Rotor is a core component of rotary machinery. Once the rotor has the damage, it may lead to a major accident. Thus the quantitative rotor damage detection method based on piezoelectric impedance is studied in this paper. With the governing equation of piezoelectric transducer (PZT) in a cylindrical coordinate, the displacement along the radius direction is derived. The charge of PZT is calculated by the electric displacement. Then, by the use of the obtained displacement and charge, an analytic piezoelectric impedance model of the rotor is built. Given the circular boundary condition of a rotor, annular elements are used as the analyzed objects and spectral element method is used to set up the damage detection model. The Electro-Mechanical (E/M) coupled impedance expression of an undamaged rotor is deduced with the application of a low-cost impedance test circuit. A Taylor expansion method is used to obtain the approximate E/M coupled impedance expression for the damaged rotor. After obtaining the difference between the undamaged and damaged rotor impedance, a rotor damage detection method is proposed. This method can directly calculate the change of bending stiffness of the structural elements, it follows that the rotor damage can be effectively detected. Finally, a preset damage configuration is used for the numerical simulation. The result shows that the quantitative damage detection algorithm based on spectral element method and piezoelectric impedance proposed in this paper can identify the location and the severity of the damaged rotor accurately.
Liu, Yuhan; Lu, Keding; Dong, Huabin; Li, Xin; Cheng, Peng; Zou, Qi; Wu, Yusheng; Liu, Xingang; Zhang, Yuanhang
2016-05-01
In the last four decades, various techniques including spectroscopic, wet chemical and mass spectrometric methods, have been developed and applied for the detection of ambient nitrous acid (HONO). We developed a HONO detection system based on long path photometry which consists of three independent modules i.e., sampling module, fluid propulsion module and detection module. In the propulsion module, solenoid pumps are applied. With solenoid pumps the pulsed flow can be computer controlled both in terms of pump stroke volume and pulse frequency, which enables the attainment of a very stable flow rate. In the detection module, a customized Liquid Waveguide Capillary Cell (LWCC) is used. The customized LWCC pre-sets the optical fiber in-coupling with the liquid wave guide, providing the option of fast startup and easy maintenance of the absorption photometry. In summer 2014, our system was deployed in a comprehensive campaign at a rural site in the North China Plain. More than one month of high quality HONO data spanning from the limit of detection to 5ppb were collected. Intercomparison of our system with another established system from Forschungszentrum Juelich is presented and discussed. In conclusion, our instrument achieved a detection limit of 10pptV within 2min and a measurement uncertainty of 7%, which is well suited for investigation of the HONO budget from urban to rural conditions in China. Copyright © 2016. Published by Elsevier B.V.
21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).
Code of Federal Regulations, 2010 CFR
2010-04-01
... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits. (b...
21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).
Code of Federal Regulations, 2012 CFR
2012-04-01
... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits. (b...
21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).
Code of Federal Regulations, 2013 CFR
2013-04-01
... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits. (b...
21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).
Code of Federal Regulations, 2011 CFR
2011-04-01
... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits. (b...
21 CFR 870.2300 - Cardiac monitor (including cardiotachometer and rate alarm).
Code of Federal Regulations, 2014 CFR
2014-04-01
... cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate.... This device may sound an alarm when the heart rate falls outside preset upper and lower limits. (b...
Standardization of pitch-range settings in voice acoustic analysis.
Vogel, Adam P; Maruff, Paul; Snyder, Peter J; Mundt, James C
2009-05-01
Voice acoustic analysis is typically a labor-intensive, time-consuming process that requires the application of idiosyncratic parameters tailored to individual aspects of the speech signal. Such processes limit the efficiency and utility of voice analysis in clinical practice as well as in applied research and development. In the present study, we analyzed 1,120 voice files, using standard techniques (case-by-case hand analysis), taking roughly 10 work weeks of personnel time to complete. The results were compared with the analytic output of several automated analysis scripts that made use of preset pitch-range parameters. After pitch windows were selected to appropriately account for sex differences, the automated analysis scripts reduced processing time of the 1,120 speech samples to less than 2.5 h and produced results comparable to those obtained with hand analysis. However, caution should be exercised when applying the suggested preset values to pathological voice populations.
Adaptive gain and filtering circuit for a sound reproduction system
NASA Technical Reports Server (NTRS)
Engebretson, A. Maynard (Inventor); O'Connell, Michael P. (Inventor)
1998-01-01
Adaptive compressive gain and level dependent spectral shaping circuitry for a hearing aid include a microphone to produce an input signal and a plurality of channels connected to a common circuit output. Each channel has a preset frequency response. Each channel includes a filter with a preset frequency response to receive the input signal and to produce a filtered signal, a channel amplifier to amplify the filtered signal to produce a channel output signal, a threshold register to establish a channel threshold level, and a gain circuit. The gain circuit increases the gain of the channel amplifier when the channel output signal falls below the channel threshold level and decreases the gain of the channel amplifier when the channel output signal rises above the channel threshold level. A transducer produces sound in response to the signal passed by the common circuit output.
Johansson, Johannes D; Eriksson, Ola; Wren, Joakim; Loyd, Dan; Wårdell, Karin
2006-09-01
Radio-frequency brain lesioning is a method for reducing e.g. symptoms of movement disorders. A small electrode is used to thermally coagulate malfunctioning tissue. Influence on lesion size from thermal and electric conductivity of the tissue, microvascular perfusion and preset electrode temperature was investigated using a finite-element model. Perfusion was modelled as an increased thermal conductivity in non-coagulated tissue. The parameters were analysed using a 2(4)-factorial design (n=16) and quadratic regression analysis (n=47). Increased thermal conductivity of the tissue increased lesion volume, while increased perfusion decreased it since coagulation creates a thermally insulating layer due to the cessation of blood perfusion. These effects were strengthened with increased preset temperature. The electric conductivity had negligible effect. Simulations were found realistic compared to in vivo experimental lesions.
Gas flow meter and method for measuring gas flow rate
Robertson, Eric P.
2006-08-01
A gas flow rate meter includes an upstream line and two chambers having substantially equal, fixed volumes. An adjustable valve may direct the gas flow through the upstream line to either of the two chambers. A pressure monitoring device may be configured to prompt valve adjustments, directing the gas flow to an alternate chamber each time a pre-set pressure in the upstream line is reached. A method of measuring the gas flow rate measures the time required for the pressure in the upstream line to reach the pre-set pressure. The volume of the chamber and upstream line are known and fixed, thus the time required for the increase in pressure may be used to determine the flow rate of the gas. Another method of measuring the gas flow rate uses two pressure measurements of a fixed volume, taken at different times, to determine the flow rate of the gas.
van der Klink, Marcel R.; van Merriënboer, Jeroen J. G.
2010-01-01
This study investigated the effect of performance-based versus competence-based assessment criteria on task performance and self-assessment skills among 39 novice secondary vocational education students in the domain of nursing and care. In a performance-based assessment group students are provided with a preset list of performance-based assessment criteria, describing what students should do, for the task at hand. The performance-based group is compared to a competence-based assessment group in which students receive a preset list of competence-based assessment criteria, describing what students should be able to do. The test phase revealed that the performance-based group outperformed the competence-based group on test task performance. In addition, higher performance of the performance-based group was reached with lower reported mental effort during training, indicating a higher instructional efficiency for novice students. PMID:20054648
Chanona, J; Ribes, J; Seco, A; Ferrer, J
2006-01-01
This paper presents a model-knowledge based algorithm for optimising the primary sludge fermentation process design and operation. This is a recently used method to obtain the volatile fatty acids (VFA), needed to improve biological nutrient removal processes, directly from the raw wastewater. The proposed algorithm consists in a heuristic reasoning algorithm based on the expert knowledge of the process. Only effluent VFA and the sludge blanket height (SBH) have to be set as design criteria, and the optimisation algorithm obtains the minimum return sludge and waste sludge flow rates which fulfil those design criteria. A pilot plant fed with municipal raw wastewater was operated in order to obtain experimental results supporting the developed algorithm groundwork. The experimental results indicate that when SBH was increased, higher solids retention time was obtained in the settler and VFA production increased. Higher recirculation flow-rates resulted in higher VFA production too. Finally, the developed algorithm has been tested by simulating different design conditions with very good results. It has been able to find the optimal operation conditions in all cases on which preset design conditions could be achieved. Furthermore, this is a general algorithm that can be applied to any fermentation-elutriation scheme with or without fermentation reactor.
Wohl, Michael J A; Gainsbury, Sally; Stewart, Melissa J; Sztainert, Travis
2013-12-01
Although most gamblers set a monetary limit on their play, many exceed this limit--an antecedent of problematic gambling. Responsible gambling tools may assist players to gamble within their means. Historically, however, the impact of such tools has been assessed in isolation. In the current research, two responsible gambling tools that target adherence to a monetary limit were assessed among 72 electronic gaming machine (EGM) players. Participants watched an educational animation explaining how EGMs work (or a neutral video) and then played an EGM in a virtual reality environment. All participants were asked to set a monetary limit on their play, but only half were reminded when that limit was reached. Results showed that both the animation and pop-up limit reminder helped gamblers stay within their preset monetary limit; however, an interaction qualified these main effects. Among participants who did not experience the pop-up reminder, those who watched the animation stayed within their preset monetary limits more than those who did not watch the animation. For those who were reminded of their limit, however, there was no difference in limit adherence between those who watched the animation and those who did not watch the animation. From a responsible gambling perspective, the current study suggests that there is no additive effect of exposure to both responsible gambling tools. Therefore, for minimal disruption in play, a pop-up message reminding gamblers of their preset monetary limit might be preferred over the lengthier educational animation.
Display-And-Alarm Circuit For Accelerometer
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr.
1995-01-01
Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.
Microprogramming for real-time data acquisition
NASA Technical Reports Server (NTRS)
Patella, F. J.
1977-01-01
Transmit microcode trap logic is conditioned by preset clock. Measurement request or issuance of command is controlled by set of software-initialized polling tables. Receive microcode trap logic is conditioned by transmit/receive hardware when response is returned on data bus.
Conversion of continuous-direct-current TIG welder to pulse-arc operation
NASA Technical Reports Server (NTRS)
Lien, D. R.
1969-01-01
Electronics package converts a continuous-dc tungsten-inert gas welder for pulse-arc operation. Package allows presetting of the pulse rate, duty cycle, and current value, and enables welding of various alloys and thicknesses of materials.
NASA Technical Reports Server (NTRS)
Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.
1995-01-01
Laser altimeters measure the time of flight of the laser pulses to determine the range of the target. The simplest altimeter receiver consists of a photodetector followed by a leading edge detector. A time interval unit (TIU) measures the time from the transmitted laser pulse to the leading edge of the received pulse as it crosses a preset threshold. However, the ranging error of this simple detection scheme depends on the received, pulse amplitude, pulse shape, and the threshold. In practice, the pulse shape and the amplitude are determined by the target target characteristics which has to be assumed unknown prior to the measurement. The ranging error can be improved if one also measures the pulse width and use the average of the leading and trailing edges (half pulse width) as the pulse arrival time. The ranging error becomes independent of the received pulse amplitude and the pulse width as long as the pulse shape is symmetric. The pulse width also gives the slope of the target. The ultimate detection scheme is to digitize the received waveform and calculate the centroid as the pulse arrival time. The centroid detection always gives unbiased measurement even for asymmetric pulses. In this report, we analyze the laser altimeter ranging errors for these three detection schemes using the Mars Orbital Laser Altimeter (MOLA) as an example.
Prinz, P; Ronacher, B
2002-08-01
The temporal resolution of auditory receptors of locusts was investigated by applying noise stimuli with sinusoidal amplitude modulations and by computing temporal modulation transfer functions. These transfer functions showed mostly bandpass characteristics, which are rarely found in other species at the level of receptors. From the upper cut-off frequencies of the modulation transfer functions the minimum integration times were calculated. Minimum integration times showed no significant correlation to the receptor spike rates but depended strongly on the body temperature. At 20 degrees C the average minimum integration time was 1.7 ms, dropping to 0.95 ms at 30 degrees C. The values found in this study correspond well to the range of minimum integration times found in birds and mammals. Gap detection is another standard paradigm to investigate temporal resolution. In locusts and other grasshoppers application of this paradigm yielded values of the minimum detectable gap widths that are approximately twice as large than the minimum integration times reported here.
DIF Detection Using Multiple-Group Categorical CFA with Minimum Free Baseline Approach
ERIC Educational Resources Information Center
Chang, Yu-Wei; Huang, Wei-Kang; Tsai, Rung-Ching
2015-01-01
The aim of this study is to assess the efficiency of using the multiple-group categorical confirmatory factor analysis (MCCFA) and the robust chi-square difference test in differential item functioning (DIF) detection for polytomous items under the minimum free baseline strategy. While testing for DIF items, despite the strong assumption that all…
Lancioni, Giulio E; Singh, Nirbhay N; O'Reilly, Mark F; Green, Vanessa A; Alberti, Gloria; Boccasini, Adele; Smaldone, Angela; Oliva, Doretta; Bosco, Andrea
2014-08-01
Assessing automatic feedback technologies to promote safe travel and speech loudness control in two men with multiple disabilities, respectively. The men were involved in two single-case studies. In Study I, the technology involved a microprocessor, two photocells, and a verbal feedback device. The man received verbal alerting/feedback when the photocells spotted an obstacle in front of him. In Study II, the technology involved a sound-detecting unit connected to a throat and an airborne microphone, and to a vibration device. Vibration occurred when the man's speech loudness exceeded a preset level. The man included in Study I succeeded in using the automatic feedback in substitution of caregivers' alerting/feedback for safe travel. The man of Study II used the automatic feedback to successfully reduce his speech loudness. Automatic feedback can be highly effective in helping persons with multiple disabilities improve their travel and speech performance.
NASA Astrophysics Data System (ADS)
Tsai, Nan-Chyuan; Sue, Chung-Yang
2010-02-01
Owing to the imposed but undesired accelerations such as quadrature error and cross-axis perturbation, the micro-machined gyroscope would not be unconditionally retained at resonant mode. Once the preset resonance is not sustained, the performance of the micro-gyroscope is accordingly degraded. In this article, a direct model reference adaptive control loop which is integrated with a modified disturbance estimating observer (MDEO) is proposed to guarantee the resonant oscillations at drive mode and counterbalance the undesired disturbance mainly caused by quadrature error and cross-axis perturbation. The parameters of controller are on-line innovated by the dynamic error between the MDEO output and expected response. In addition, Lyapunov stability theory is employed to examine the stability of the closed-loop control system. Finally, the efficacy of numerical evaluation on the exerted time-varying angular rate, which is to be detected and measured by the gyroscope, is verified by intensive simulations.
Method and apparatus for checking fire detectors
NASA Technical Reports Server (NTRS)
Clawson, G. T. (Inventor)
1974-01-01
A fire detector checking method and device are disclosed for nondestructively verifying the operation of installed fire detectors of the type which operate on the principle of detecting the rate of temperature rise of the ambient air to sound an alarm and/or which sound an alarm when the temperature of the ambient air reaches a preset level. The fire alarm checker uses the principle of effecting a controlled simulated alarm condition to ascertain wheather or not the detector will respond. The checker comprises a hand-held instrument employing a controlled heat source, e.g., an electric lamp having a variable input, for heating at a controlled rate an enclosed mass of air in a first compartment, which air mass is then disposed about the fire detector to be checked. A second compartment of the device houses an electronic circuit to sense and adjust the temperature level and heating rate of the heat source.
Microcomputer keeps watch at Emerald Mine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-04-01
Where there's smoke, there's fire. Take the old adage a step further: ''Where there's carbon monoxide, there's likely to be a fire.'' That's the principle behind the mine monitoring system being used at the Emerald Mine operated by Emway Resources. Instead of watching for smoke or temperature rises, the system uses carbon monoxide (CO) sensors to detect fires - before they break out. CO, a gaseous product of incomplete combustion, is present in the early stages of a fire. Carried by the mine ventilation air, CO can be quickly traced by electrochemical gas sensors that are wired to a centralmore » computer. When preset levels are reached, alarms can alert mine personnel of the trouble. The Emerald Mine is located in southwestern Pennsylvania, near Waynesburg, and mines the Pittsburgh Seam, the nation's most heavily mined seam. Emerald is one of a number of progressive mines that are turning to computers to improve safety and productivity.« less
Air/fuel ratio control system for internal combustion engine having rotary valve and step motor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saito, M.
A system for feedback control of the air/fuel mixing ratio in an internal combustion engine equipped with a carburetor. The control system has an air/fuel ratio detector of a gas sensor type which provides a feedback signal to a control circuit and a rotary valve which is operated by a stepping motor responsive to a control pulse signal produced by the control circuit to regulate the fuel feed rate so as to nullify a deviation of the detected actual air/fuel ratio from a preset air/fuel ratio. The control system may include two auxiliary air-admitting passages respectively connected to a mainmore » fuel passage and a slow fuel passage in the carburetor, and in this case the single rotary valve is designed and arranged so as to simultaneously control the admission of air into both of the two auxiliary air-admitting passages.« less
A search for narrow band signals with SERENDIP II: a progress report
NASA Technical Reports Server (NTRS)
Werthimer, D.; Brady, R.; Berezin, A.; Bowyer, S.
1988-01-01
Commensal programs for the Search for Extraterrestrial Intelligence (SETI), carried out concurrently with conventional radio astronomical observing programs, can be an attractive and cost-effective means of exploring the large multidimensional search space intrinsic to this effort. Our automated commensal system, SERENDIP II, is a high resolution 131,072 channel spectrometer. It searches for 0.49 Hz signals in sequential 64,700 Hz bands of the IF signal from a radio telescope being used for an astronomical observation. Upon detection of a narrow band signal with power above a preset threshold, the frequency, power, time, and telescope direction are recorded for later study. The system has been tested at the Hat Creek Radio Astronomy Observatory 85 ft telescope and the NASA-JPL Deep Space Station (DSS 14) 64 m telescope. It is currently collecting data at the National Radio Astronomy Observatory 300 ft telescope.
A search for narrow band signals with SERENDIP II: a progress report.
Werthimer, D; Brady, R; Berezin, A; Bowyer, S
1988-01-01
Commensal programs for the Search for Extraterrestrial Intelligence (SETI), carried out concurrently with conventional radio astronomical observing programs, can be an attractive and cost-effective means of exploring the large multidimensional search space intrinsic to this effort. Our automated commensal system, SERENDIP II, is a high resolution 131,072 channel spectrometer. It searches for 0.49 Hz signals in sequential 64,700 Hz bands of the IF signal from a radio telescope being used for an astronomical observation. Upon detection of a narrow band signal with power above a preset threshold, the frequency, power, time, and telescope direction are recorded for later study. The system has been tested at the Hat Creek Radio Astronomy Observatory 85 ft telescope and the NASA-JPL Deep Space Station (DSS 14) 64 m telescope. It is currently collecting data at the National Radio Astronomy Observatory 300 ft telescope.
Pradhan, Somarpita; Chaudhuri, Partha Roy
2015-07-10
We experimentally demonstrate single-mode optical-fiber-beam-deflection configuration for weak magnetic-field-detection using an optimized (low coercive-field) composition of cobalt-doped nickel ferrite nanoparticles. Devising a fiber-double-slit type experiment, we measure the surrounding magnetic field through precisely measuring interference-fringe yielding a minimum detectable field ∼100 mT and we procure magnetization data of the sample that fairly predicts SQUID measurement. To improve sensitivity, we incorporate etched single-mode fiber in double-slit arrangement and recorded a minimum detectable field, ∼30 mT. To further improve, we redefine the experiment as modulating fiber-to-fiber light-transmission and demonstrate the minimum field as 2.0 mT. The device will be uniquely suited for electrical or otherwise hazardous environments.
2014-06-01
C. MODTRAN ....................................................................................................34 1. Preset Atmospheric Models ...37 3. Aerosol Models ...................................................................................38 4. Cloud and Rain Models ...52 E. MODEL VALIDATION ...............................................................................53 VI. RESULTS
Predictive Eco-Cruise Control (ECC) system : model development, modeling and potential benefits.
DOT National Transportation Integrated Search
2013-02-01
The research develops a reference model of a predictive eco-cruise control (ECC) system that intelligently modulates vehicle speed within a pre-set speed range to minimize vehicle fuel consumption levels using roadway topographic information. The stu...
Limit circuit prevents overdriving of operational amplifier
NASA Technical Reports Server (NTRS)
Openshaw, F. L.
1967-01-01
Cutoff-type high gain amplifier coupled by a diode prevents overdriving of operational amplifier. An amplified feedback signal offsets the excess input signal that tends to cause the amplifier to exceed its preset limit. The output is, therfore, held to the set clamp level.
Sustainable intersection control to accommodate urban freight mobility.
DOT National Transportation Integrated Search
2009-08-01
In this research, we studied green extension of a two-phased vehicleactuated signal at an isolated : intersection between two one-way streets. The green phase is extended by a preset time interval, referred to : as critical gap, from the time of a...
Biesta-Peters, Elisabeth G.; Reij, Martine W.; Zwietering, Marcel H.; Gorris, Leon G. M.
2011-01-01
This research aims to test the absence (gamma hypothesis) or occurrence of synergy between two growth-limiting factors, i.e., pH and water activity (aw), using a systematic approach for model selection. In this approach, preset criteria were used to evaluate the performance of models. Such a systematic approach is required to be confident in the correctness of the individual components of the combined (synergy) models. With Bacillus cereus F4810/72 as the test organism, estimated growth boundaries for the aw-lowering solutes NaCl, KCl, and glucose were 1.13 M, 1.13 M, and 1.68 M, respectively. The accompanying aw values were 0.954, 0.956, and 0.961, respectively, indicating that equal aw values result in similar effects on growth. Out of the 12 models evaluated using the preset criteria, the model of J. H. T. Luong (Biotechnol. Bioeng. 27:280–285, 1985) was the best model to describe the effect of aw on growth. This aw model and the previously selected pH model were combined into a gamma model and into two synergy models. None of the three models was able to describe the combined pH and aw conditions sufficiently well to satisfy the preset criteria. The best matches between predicted and experimental data were obtained with the gamma model, followed by the synergy model of Y. Le Marc et al. (Int. J. Food Microbiol. 73:219–237, 2002). No combination of models that was able to predict the impact of both individual and combined hurdles correctly could be found. Consequently, in this case we could not prove the existence of synergy nor falsify the gamma hypothesis. PMID:21705525
Lace Up for Healthy Feet: The Impact of Shoe Closure on Plantar Stress Response.
Rahemi, Hadi; Armstrong, David G; Enriquez, Ana; Owl, Joshua; Talal, Talal K; Najafi, Bijan
2017-07-01
This study examined the impact of shoe closure on plantar thermal stress response (TSR), which is known to be a surrogate of shear stress and skin perfusion. It is aimed to explore potential impact of shoe closure on increasing risk factors associated with plantar ulcers in people with diabetic peripheral neuropathy (DPN). Fifteen eligible subjects were enrolled. The left foot was used as a reference and fitted to a self-adjusted and habitual lace-tightening method by each subject. The right foot was used as a test closure and fitted into three lace closure conditions: loose, tight, and preset optimal closure (reel clutch, BOA technology). Thermal images were taken after 5 minutes of acclimatization (pre-trial) and immediately after 200 walking steps in each shoe closure condition (post-trial). TSR was calculated from the thermal images. TSR was significantly higher in the test closure with loose (70.24%, P = .000) and tight (66.85%, P = .007) and lower (-206.53%, P = .000) in the preset optimal closure when compared to the reference closure. Only lace closure conditions affected TSR with no significant impact from age, BMI, and gender in our sample in a multivariable regression model. The results from this study suggest that shoelace closure technique can have a profound effect on TSR. It therefore stands to reason that optimal lace closure may have an impact in reducing risk of plantar ulcers in people with DPN. Interestingly, results revealed that even a self-adjusted lace closure may not be necessarily optimal and a preset closure setting like reel clutch might ultimately be recommended to minimize risk. Further study is warranted to confirm or refute these interesting results.
Poleti, Marcelo Lupion; Fernandes, Thais Maria Freire; Pagin, Otávio; Moretti, Marcela Rodrigues; Rubira-Bullen, Izabel Regina Fischer
2016-01-01
The aim of this in vitro study was to evaluate the reliability and accuracy of linear measurements on three-dimensional (3D) surface models obtained by standard pre-set thresholds in two segmentation software programs. Ten mandibles with 17 silica markers were scanned for 0.3-mm voxels in the i-CAT Classic (Imaging Sciences International, Hatfield, PA, USA). Twenty linear measurements were carried out by two observers two times on the 3D surface models: the Dolphin Imaging 11.5 (Dolphin Imaging & Management Solutions, Chatsworth, CA, USA), using two filters(Translucent and Solid-1), and in the InVesalius 3.0.0 (Centre for Information Technology Renato Archer, Campinas, SP, Brazil). The physical measurements were made by another observer two times using a digital caliper on the dry mandibles. Excellent intra- and inter-observer reliability for the markers, physical measurements, and 3D surface models were found (intra-class correlation coefficient (ICC) and Pearson's r ≥ 0.91). The linear measurements on 3D surface models by Dolphin and InVesalius software programs were accurate (Dolphin Solid-1 > InVesalius > Dolphin Translucent). The highest absolute and percentage errors were obtained for the variable R1-R1 (1.37 mm) and MF-AC (2.53 %) in the Dolphin Translucent and InVesalius software, respectively. Linear measurements on 3D surface models obtained by standard pre-set thresholds in the Dolphin and InVesalius software programs are reliable and accurate compared with physical measurements. Studies that evaluate the reliability and accuracy of the 3D models are necessary to ensure error predictability and to establish diagnosis, treatment plan, and prognosis in a more realistic way.
Si, Xingfeng; Kays, Roland
2014-01-01
Camera traps is an important wildlife inventory tool for estimating species diversity at a site. Knowing what minimum trapping effort is needed to detect target species is also important to designing efficient studies, considering both the number of camera locations, and survey length. Here, we take advantage of a two-year camera trapping dataset from a small (24-ha) study plot in Gutianshan National Nature Reserve, eastern China to estimate the minimum trapping effort actually needed to sample the wildlife community. We also evaluated the relative value of adding new camera sites or running cameras for a longer period at one site. The full dataset includes 1727 independent photographs captured during 13,824 camera days, documenting 10 resident terrestrial species of birds and mammals. Our rarefaction analysis shows that a minimum of 931 camera days would be needed to detect the resident species sufficiently in the plot, and c. 8700 camera days to detect all 10 resident species. In terms of detecting a diversity of species, the optimal sampling period for one camera site was c. 40, or long enough to record about 20 independent photographs. Our analysis of evaluating the increasing number of additional camera sites shows that rotating cameras to new sites would be more efficient for measuring species richness than leaving cameras at fewer sites for a longer period. PMID:24868493
Circuit protects regulated power supply against overload current
NASA Technical Reports Server (NTRS)
Airth, H. B.
1966-01-01
Sensing circuit in which a tunnel diode controls a series regulator transistor protects a low voltage transistorized dc regulator from damage by excessive load currents. When a fault occurs, the faulty circuit is limited to a preset percentage of the current when limiting first occurs.
77 FR 76606 - Community Development Financial Institutions Fund
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-28
... form, with pre-set text limits and font size restrictions. Applicants must submit their narrative responses by using the FY 2013 CDFI Program Application narrative template document. This Word document...) A-133 Narrative Report; (iv) Institution Level Report; (v) Transaction Level Report (for Awardees...
Big Data Toolsets to Pharmacometrics: Application of Machine Learning for Time‐to‐Event Analysis
Gong, Xiajing; Hu, Meng
2018-01-01
Abstract Additional value can be potentially created by applying big data tools to address pharmacometric problems. The performances of machine learning (ML) methods and the Cox regression model were evaluated based on simulated time‐to‐event data synthesized under various preset scenarios, i.e., with linear vs. nonlinear and dependent vs. independent predictors in the proportional hazard function, or with high‐dimensional data featured by a large number of predictor variables. Our results showed that ML‐based methods outperformed the Cox model in prediction performance as assessed by concordance index and in identifying the preset influential variables for high‐dimensional data. The prediction performances of ML‐based methods are also less sensitive to data size and censoring rates than the Cox regression model. In conclusion, ML‐based methods provide a powerful tool for time‐to‐event analysis, with a built‐in capacity for high‐dimensional data and better performance when the predictor variables assume nonlinear relationships in the hazard function. PMID:29536640
Remote Laser Welding of Zinc Coated Steel Sheets in an Edge Lap Configuration with Zero Gap
NASA Astrophysics Data System (ADS)
Roos, Christian; Schmidt, Michael
Remote Laser Welding (RLW) of zinc-coated steel sheets is a great challenge for the automotive industry but offers high potentials with respect to flexibility and costs. In state of the art applications, sheets are joined in overlap configuration with a preset gap for a stable zinc degassing. This paper investigates RLW of fillets without a preset gap and conditions for a stable process. The influence of process parameters on weld quality and process stability is shown. Experimental data give evidence, that the degassing of zinc through the capillary and the rear melt pool are the major degassing mechanisms. Furthermore the paper gives experimental validation of the zinc degassing in advance of the process zone to the open side of the fillet. Chemical analysis of the hot-dip galvanized zinc coating proof the iron-zinc-alloys to be the reason for a limited effectiveness of this mechanism in comparison to pure zinc as intermediate.
Design and implementation of a low-cost multiple-range digital phase detector
NASA Astrophysics Data System (ADS)
Omran, Hesham; Albasha, Lutfi; Al-Ali, A. R.
2012-06-01
This article describes the design, simulation, implementation and testing of a novel low-cost multiple-range programmable digital phase detector. The detector receives two periodic signals and calculates the ratio of the time difference to the time period to measure and display the phase difference. The resulting output values are in integer form ranging from -180° to 180°. Users can select the detector pre-set operation frequency ranges using a three-bit pre-scalar. This enables to use the detector for various applications. The proposed detector can be programmed over a frequency range of 10 Hz to 25 kHz by configuring its clock divider circuit. Detector simulations were conducted and verified using ModelSim and the design was implemented and tested using an Altera Cyclone II field-programmable gate array board. Both the simulation and actual circuit testing results showed that the phase detector has a magnitude of error of only 1°. The detector is ideal for applications such as power factor measurement and correction, self-tuning resonant circuits and in metal detection systems. Unlike other stand-alone phase detection systems, the reported system has the ability to be programmed to several frequency ranges, hence expanding its bandwidth.
Saleh, Shadi; Alameddine, Mohamad; Farah, Angie; El Arnaout, Nour; Dimassi, Hani; Muntaner, Carles; El Morr, Christo
2018-06-01
Assess the effect of selected low-cost eHealth tools on diabetes/hypertension detection and referrals rates in rural settings and refugee camps in Lebanon and explore the barriers to showing-up to scheduled appointments at Primary Healthcare Centers (PHC). Community-based screening for diabetes and hypertension was conducted in five rural and three refugee camp PHCs using an eHealth netbook application. Remote referrals were generated based on pre-set criteria. A phone survey was subsequently conducted to assess the rate and causes of no-shows to scheduled appointments. Associations between the independent variables and the outcome of referrals were then tested. Among 3481 screened individuals, diabetes, hypertension, and comorbidity were detected in 184,356 and 113 per 1000 individuals, respectively. 37.1% of referred individuals reported not showing-up to scheduled appointments, owing to feeling better/symptoms resolved (36.9%) and having another obligation (26.1%). The knowledge of referral reasons and the employment status were significantly associated with appointment show-ups. Low-cost eHealth netbook application was deemed effective in identifying new cases of NCDs and establishing appropriate referrals in underserved communities.
Detecting Hardware-assisted Hypervisor Rootkits within Nested Virtualized Environments
2012-06-14
least the minimum required for the guest OS and click “Next”. For 64-bit Windows 7 the minimum required is 2048 MB (Figure 66). Figure 66. Memory...prompted for Memory, allocate at least the minimum required for the guest OS, for 64-bit Windows 7 the minimum required is 2048 MB (Figure 79...130 21. Within the virtual disk creation wizard, select VDI for the file type (Figure 81). Figure 81. Select File Type 22. Select Dynamically
21 CFR 211.125 - Labeling issuance.
Code of Federal Regulations, 2010 CFR
2010-04-01
... shall be used to reconcile the quantities of labeling issued, used, and returned, and shall require... issued when such discrepancies are outside narrow preset limits based on historical operating data. Such....122(g)(2). (d) All excess labeling bearing lot or control numbers shall be destroyed. (e) Returned...
Code of Federal Regulations, 2011 CFR
2011-01-01
...-23 series), or a personnel-carrying U.S. military parachute (other than a high altitude, high speed... deployment of the reserve parachute at a pre-set altitude, time, percentage of terminal velocity, or... is inflated by ram air entering through specially designed openings in the front of the canopy to...
Yassi, Annalee; O'Hara, Lyndsay M; Lockhart, Karen; Spiegel, Jerry M
2013-01-01
The health service sector has a vital role to play in delivering human immunodeficiency virus (HIV) and tuberculosis (TB) prevention, treatment and care, yet evidence indicates that healthcare workers (HCWs) themselves lack adequate access to HIV and TB services. HCWs are also at increased risk from TB and other infectious diseases at work, and therefore accessing HIV services is particularly important. A systematic review was therefore conducted to inform the development of World Health Organization (WHO) guidelines to improve access to HIV and TB services, and specifically, to assess the evidence regarding providing such services through workplace-based programmes. We identified any study published since 1984 that addressed outcomes of interest as defined through multi-stakeholder consultations, and were related to workplace interventions in (1) the healthcare workplace and (2) any workplace that included HIV and/or TB diagnosis and/or treatment. Interventions focusing solely on primary prevention with no diagnostic or treatment services were excluded, as they were the subject of other guidelines. A minimum of two reviewers independently extracted data and assessed the articles against pre-set selection criteria; studies were also profiled and quality assessed by a minimum of two reviewers. Three studies met these criteria specifically for HCWs; all showed a preponderance of positive benefits, with minimal negative outcome. Seven studies met these criteria regarding workplace HIV and/or TB diagnosis and/or treatment from other sectors, public or private. Again, all showed positive results. The paucity of high-quality evidence in this field of research was itself an important finding, beckoning further research on workplace-based programmes for health workers. Nonetheless, while more well-designed intervention studies are definitely desirable, providing programmes for HCWs to obtain HIV and TB diagnosis and treatment at the workplace is supported by the literature and is consistent with the values of the stakeholders, justifying the WHO-International Labour Organization-UNAIDS guidelines that emerged.
HPNAIDM: The High-Performance Network Anomaly/Intrusion Detection and Mitigation System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yan
Identifying traffic anomalies and attacks rapidly and accurately is critical for large network operators. With the rapid growth of network bandwidth, such as the next generation DOE UltraScience Network, and fast emergence of new attacks/virus/worms, existing network intrusion detection systems (IDS) are insufficient because they: • Are mostly host-based and not scalable to high-performance networks; • Are mostly signature-based and unable to adaptively recognize flow-level unknown attacks; • Cannot differentiate malicious events from the unintentional anomalies. To address these challenges, we proposed and developed a new paradigm called high-performance network anomaly/intrustion detection and mitigation (HPNAIDM) system. The new paradigm ismore » significantly different from existing IDSes with the following features (research thrusts). • Online traffic recording and analysis on high-speed networks; • Online adaptive flow-level anomaly/intrusion detection and mitigation; • Integrated approach for false positive reduction. Our research prototype and evaluation demonstrate that the HPNAIDM system is highly effective and economically feasible. Beyond satisfying the pre-set goals, we even exceed that significantly (see more details in the next section). Overall, our project harvested 23 publications (2 book chapters, 6 journal papers and 15 peer-reviewed conference/workshop papers). Besides, we built a website for technique dissemination, which hosts two system prototype release to the research community. We also filed a patent application and developed strong international and domestic collaborations which span both academia and industry.« less
Demonstration of a vectorial optical field generator with adaptive close loop control.
Chen, Jian; Kong, Lingjiang; Zhan, Qiwen
2017-12-01
We experimentally demonstrate a vectorial optical field generator (VOF-Gen) with an adaptive close loop control. The close loop control capability is illustrated with the calibration of polarization modulation of the system. To calibrate the polarization ratio modulation, we generate 45° linearly polarized beam and make it propagate through a linear analyzer whose transmission axis is orthogonal to the incident beam. For the retardation calibration, circularly polarized beam is employed and a circular polarization analyzer with the opposite chirality is placed in front of the CCD as the detector. In both cases, the close loop control automatically changes the value of the corresponding calibration parameters in the pre-set ranges to generate the phase patterns applied to the spatial light modulators and records the intensity distribution of the output beam by the CCD camera. The optimized calibration parameters are determined corresponding to the minimum total intensity in each case. Several typical kinds of vectorial optical beams are created with and without the obtained calibration parameters, and the full Stokes parameter measurements are carried out to quantitatively analyze the polarization distribution of the generated beams. The comparisons among these results clearly show that the obtained calibration parameters could remarkably improve the accuracy of the polarization modulation of the VOF-Gen, especially for generating elliptically polarized beam with large ellipticity, indicating the significance of the presented close loop in enhancing the performance of the VOF-Gen.
Physiological and biochemical responses of Prorocentrum minimum to high light stress
NASA Astrophysics Data System (ADS)
Park, So Yun; Choi, Eun Seok; Hwang, Jinik; Kim, Donggiun; Ryu, Tae Kwon; Lee, Taek-Kyun
2009-12-01
Prorocentrum minimum is a common bloomforming photosynthetic dinoflagellate found along the southern coast of Korea. To investigate the adaptive responses of P. minimum to high light stress, we measured growth rate, and generation of reactive oxidative species (ROS), superoxide dismutase (SOD), catalase (CAT), and malondialdehyde (MDA) in cultures exposed to normal (NL) and high light levels (HL). The results showed that HL (800 μmol m-2 s-1) inhibited growth of P. minimum, with maximal inhibition after 7-9 days. HL also increased the amount of ROS and MDA, suggesting that HL stress leads to oxidative damage and lipid peroxidation in this species. Under HL, we first detected superoxide on day 4 and H2O2 on day 5. We also detected SOD activity on day 5 and CAT activity on day 6. The level of lipid peroxidation, an indicator of cell death, was high on day 8. Addition of diphenyleneiodonium (DPI), an NAD(P)H inhibitor, decreased the levels of superoxide generation and lipid peroxidation. Our results indicate that the production of ROS which results from HL stress in P. minimum also induces antioxidative enzymes that counteract oxidative damage and allow P. minimum to survive.
Petitot, Maud; Manceau, Nicolas; Geniez, Philippe; Besnard, Aurélien
2014-09-01
Setting up effective conservation strategies requires the precise determination of the targeted species' distribution area and, if possible, its local abundance. However, detection issues make these objectives complex for most vertebrates. The detection probability is usually <1 and is highly dependent on species phenology and other environmental variables. The aim of this study was to define an optimized survey protocol for the Mediterranean amphibian community, that is, to determine the most favorable periods and the most effective sampling techniques for detecting all species present on a site in a minimum number of field sessions and a minimum amount of prospecting effort. We visited 49 ponds located in the Languedoc region of southern France on four occasions between February and June 2011. Amphibians were detected using three methods: nighttime call count, nighttime visual encounter, and daytime netting. The detection nondetection data obtained was then modeled using site-occupancy models. The detection probability of amphibians sharply differed between species, the survey method used and the date of the survey. These three covariates also interacted. Thus, a minimum of three visits spread over the breeding season, using a combination of all three survey methods, is needed to reach a 95% detection level for all species in the Mediterranean region. Synthesis and applications: detection nondetection surveys combined to site occupancy modeling approach are powerful methods that can be used to estimate the detection probability and to determine the prospecting effort necessary to assert that a species is absent from a site.
Electropneumatic rheostat regulates high current
NASA Technical Reports Server (NTRS)
Haacker, J. F.; Jedlicka, J. R.; Wagoner, C. B.
1965-01-01
Electropneumatic rheostat maintains a constant direct current in each of several high-power parallel loads, of variable resistance, across a single source. It provides current regulation at any preset value by dissipating the proper amount of energy thermally, and uses a column of mercury to vary the effective length of a resistance element.
For Emergency Alerts, Some Colleges Try Sirens
ERIC Educational Resources Information Center
Young, Jeffrey R.
2008-01-01
Colleges and universities, ever more mindful of campus safety, are installing outdoor sirens. The systems can blast spoken messages or tone alerts of danger--and one of the preset messages on many of the public-address systems warns: "There is a shooter on campus. Seek shelter immediately." As college officials reviewed their…
L band brightness temperature observations over a corn canopy during the entire growth cycle
USDA-ARS?s Scientific Manuscript database
During a field campaign covering the 2002 corn growing season, a dual polarized tower mounted L-band (1.4 GHz) radiometer (LRAD) provided brightness temperature (T¬B) measurements at preset intervals, incidence and azimuth angles. These radiometer measurements were supported by an extensive characte...
Modified hydraulic braking system limits angular deceleration to safe values
NASA Technical Reports Server (NTRS)
Briggs, R. S.; Council, M.; Green, P. M.
1966-01-01
Conventional spring actuated, hydraulically released, fail-safe disk braking system is modified to control the angular deceleration of a massive antenna. The hydraulic system provides an immediate preset pressure to the spring-loaded brake shoes and holds it at this value to decelerate the antenna at the desired rate.
POU/POE TREATMENT OF ARSENIC IN GROUND WATER
Point-of-use/Point-of-entry (POU/POE) arsenic removal systems were installed in seventeen homes that were found to have high levels of arsenic (50-480ug/L) in their well water. This presetation will describe the process and the problems encountered in selecting the treatment syst...
Gregurech, S.
1984-08-01
A saturation meter for use in a pressurized water reactor plant comprising a differential pressure transducer having a first and second pressure sensing means and an alarm. The alarm is connected to the transducer and is preset to activate at a level of saturation prior to the formation of a steam void in the reactor vessel.
Letter report on a straw-man modification of an ATC transponder for discrete address use
DOT National Transportation Integrated Search
1974-05-01
An experimental evaluation has been made of an RCA AVQ-65 airtraffic control transponder modified, in Mode D, so as to reply if and only if interrogated with its own preset reply code. Successful operation of the modified transponder was verified, an...
Cytokine antibody array analysis in brain and periphery of scrapie-infected Tg338 mice
USDA-ARS?s Scientific Manuscript database
Scrapie is a naturally occurring transmissible spongiform encephalopathy (TSE) that affects sheep and goats. While a change in prion protein conformation has been established as an important aspect of disease, other aspects of TSE pathogenesis are not fully understood. The preset study used protei...
Phase-lock loop frequency control and the dropout problem
NASA Technical Reports Server (NTRS)
Attwood, S.; Kline, A. J.
1968-01-01
Technique automatically sets the frequency of narrow band phase-lock loops within automatic lock-in-range. It presets a phase-lock loop to a desired center frequency with a closed loop electronic frequency discriminator and holds the phase-lock loop to that center frequency until lock is achieved.
A WHOLE-LAKE WATER QUALITY SURVEY OF LAKE OAHE BASED ON A SPATIALLY-BALANCED PROBABILISTIC DESIGN
Assessing conditions on large bodies of water presets multiple statistical and logistical challenges. As part of the Upper Missouri River Program of the Environmental Monitoring and Assessment Project (EMAP) we surveyed water quality of Lake Oahe in July-August, 2002 using a spat...
Infant Contingency Learning in Different Cultural Contexts
ERIC Educational Resources Information Center
Graf, Frauke; Lamm, Bettina; Goertz, Claudia; Kolling, Thorsten; Freitag, Claudia; Spangler, Sibylle; Fassbender, Ina; Teubert, Manuel; Vierhaus, Marc; Keller, Heidi; Lohaus, Arnold; Schwarzer, Gudrun; Knopf, Monika
2012-01-01
Three-month-old Cameroonian Nso farmer and German middle-class infants were compared regarding learning and retention in a computerized mobile task. Infants achieving a preset learning criterion during reinforcement were tested for immediate and long-term retention measured in terms of an increased response rate after reinforcement and after a…
A Demonstration and a Souvenir
ERIC Educational Resources Information Center
Lentz, Randy
1978-01-01
Describes an activity using interchangeable, preset tool holders to provide a demonstration for parents or students attending a school's open house session that produces a small souvenir (an aluminum mini-chalice) for them. A procedure sheet for the school's individual lathe and specification diagrams for making the cup are provided. (TA)
Charge control of nickel-cadmium batteries by coulometer and third electrode method
NASA Technical Reports Server (NTRS)
Ford, F.; Paulkovitch, J.
1968-01-01
Combined coulometer/third electrode control circuit for a nickel-cadmium battery included at least one cell of the third electrode type is illustrated. The coulometer/third electrode sensing circuit controls the series regulator as necessary to maintain the sensing voltage at the preset sensing level.
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
Application of Twin Beams in Mach-Zehnder Interferometer
NASA Technical Reports Server (NTRS)
Zhang, J. X.; Xie, C. D.; Peng, K. C.
1996-01-01
Using the twin beams generated from parametric amplifier to drive the two port of a Mach-Zehnder interferometer, it is shown that the minimum detectable optical phase shift can be largly reduced to the Heisenberg limit(1/n) which is far below the Shot Noise Limit(1/square root of n) the large gain limit. The dependence of the minimum detectable phase shift on parametric gain and the inefficient photodetectors has been discussed.
Analysis of Aircraft Fuels and Related Materials
1982-09-01
content by the Karl Fischer method . Each 2040 solvent sample represented a different step in a clean-up procedure conducted by Aero Propulsion...izes a potentiometric titration with alcoholic silver nitrate. This method has a minimum detectability of 1 ppm. It has a re- peatability of 0.1 ppm... Method 163-80, which util- izes a potentiometric titration with alcoholic silver nitrate. This method has a minimum detectability of 1 ppm and has a
Methods for the preparation and analysis of solids and suspended solids for methylmercury
DeWild, John F.; Olund, Shane D.; Olson, Mark L.; Tate, Michael T.
2004-01-01
This report presents the methods and method performance data for the determination of methylmercury concentrations in solids and suspended solids. Using the methods outlined here, the U.S. Geological Survey's Wisconsin District Mercury Laboratory can consistently detect methylmercury in solids and suspended solids at environmentally relevant concentrations. Solids can be analyzed wet or freeze dried with a minimum detection limit of 0.08 ng/g (as-processed). Suspended solids must first be isolated from aqueous matrices by filtration. The minimum detection limit for suspended solids is 0.01 ng per filter resulting in a minimum reporting limit ranging from 0.2 ng/L for a 0.05 L filtered volume to 0.01 ng/L for a 1.0 L filtered volume. Maximum concentrations for both matrices can be extended to cover nearly any amount of methylmercury by limiting sample size.
NASA Astrophysics Data System (ADS)
Villarini, Gabriele; Khouakhi, Abdou; Cunningham, Evan
2017-12-01
Daily temperature values are generally computed as the average of the daily minimum and maximum observations, which can lead to biases in the estimation of daily averaged values. This study examines the impacts of these biases on the calculation of climatology and trends in temperature extremes at 409 sites in North America with at least 25 years of complete hourly records. Our results show that the calculation of daily temperature based on the average of minimum and maximum daily readings leads to an overestimation of the daily values of 10+ % when focusing on extremes and values above (below) high (low) thresholds. Moreover, the effects of the data processing method on trend estimation are generally small, even though the use of the daily minimum and maximum readings reduces the power of trend detection ( 5-10% fewer trends detected in comparison with the reference data).
NASA Technical Reports Server (NTRS)
Munchak, S. Joseph; Skofronick-Jackson, Gail
2012-01-01
During the middle part of this decade a wide variety of passive microwave imagers and sounders will be unified in the Global Precipitation Measurement (GPM) mission to provide a common basis for frequent (3 hr), global precipitation monitoring. The ability of these sensors to detect precipitation by discerning it from non-precipitating background depends upon the channels available and characteristics of the surface and atmosphere. This study quantifies the minimum detectable precipitation rate and fraction of precipitation detected for four representative instruments (TMI, GMI, AMSU-A, and AMSU-B) that will be part of the GPM constellation. Observations for these instruments were constructed from equivalent channels on the SSMIS instrument on DMSP satellites F16 and F17 and matched to precipitation data from NOAA's National Mosaic and QPE (NMQ) during 2009 over the continuous United States. A variational optimal estimation retrieval of non-precipitation surface and atmosphere parameters was used to determine the consistency between the observed brightness temperatures and these parameters, with high cost function values shown to be related to precipitation. The minimum detectable precipitation rate, defined as the lowest rate for which probability of detection exceeds 50%, and the detected fraction of precipitation, are reported for each sensor, surface type (ocean, coast, bare land, snow cover) and precipitation type (rain, mix, snow). The best sensors over ocean and bare land were GMI (0.22 mm/hr minimum threshold and 90% of precipitation detected) and AMSU (0.26 mm/hr minimum threshold and 81% of precipitation detected), respectively. Over coasts (0.74 mm/hr threshold and 12% detected) and snow-covered surfaces (0.44 mm/hr threshold and 23% detected), AMSU again performed best but with much lower detection skill, whereas TMI had no skill over these surfaces. The sounders (particularly over water) benefited from the use of re-analysis data (vs. climatology) to set the a-priori atmospheric state and all instruments benefit from the use of a conditional snow cover emissivity database over land. It is recommended that real-time sources of these data be used in the operational GPM precipitation algorithms.
An Ultra-Low-Power RFID/NFC Frontend IC Using 0.18 μm CMOS Technology for Passive Tag Applications.
Bhattacharyya, Mayukh; Gruenwald, Waldemar; Jansen, Dirk; Reindl, Leonhard; Aghassi-Hagmann, Jasmin
2018-05-07
Battery-less passive sensor tags based on RFID or NFC technology have achieved much popularity in recent times. Passive tags are widely used for various applications like inventory control or in biotelemetry. In this paper, we present a new RFID/NFC frontend IC (integrated circuit) for 13.56 MHz passive tag applications. The design of the frontend IC is compatible with the standard ISO 15693/NFC 5. The paper discusses the analog design part in details with a brief overview of the digital interface and some of the critical measured parameters. A novel approach is adopted for the demodulator design, to demodulate the 10% ASK (amplitude shift keying) signal. The demodulator circuit consists of a comparator designed with a preset offset voltage. The comparator circuit design is discussed in detail. The power consumption of the bandgap reference circuit is used as the load for the envelope detection of the ASK modulated signal. The sub-threshold operation and low-supply-voltage are used extensively in the analog design—to keep the power consumption low. The IC was fabricated using 0.18 μ m CMOS technology in a die area of 1.5 mm × 1.5 mm and an effective area of 0.7 m m 2 . The minimum supply voltage desired is 1.2 V, for which the total power consumption is 107 μ W. The analog part of the design consumes only 36 μ W, which is low in comparison to other contemporary passive tags ICs. Eventually, a passive tag is developed using the frontend IC, a microcontroller, a temperature and a pressure sensor. A smart NFC device is used to readout the sensor data from the tag employing an Android-based application software. The measurement results demonstrate the full passive operational capability. The IC is suitable for low-power and low-cost industrial or biomedical battery-less sensor applications. A figure-of-merit (FOM) is proposed in this paper which is taken as a reference for comparison with other related state-of-the-art researches.
An Ultra-Low-Power RFID/NFC Frontend IC Using 0.18 μm CMOS Technology for Passive Tag Applications
Gruenwald, Waldemar; Jansen, Dirk; Aghassi-Hagmann, Jasmin
2018-01-01
Battery-less passive sensor tags based on RFID or NFC technology have achieved much popularity in recent times. Passive tags are widely used for various applications like inventory control or in biotelemetry. In this paper, we present a new RFID/NFC frontend IC (integrated circuit) for 13.56 MHz passive tag applications. The design of the frontend IC is compatible with the standard ISO 15693/NFC 5. The paper discusses the analog design part in details with a brief overview of the digital interface and some of the critical measured parameters. A novel approach is adopted for the demodulator design, to demodulate the 10% ASK (amplitude shift keying) signal. The demodulator circuit consists of a comparator designed with a preset offset voltage. The comparator circuit design is discussed in detail. The power consumption of the bandgap reference circuit is used as the load for the envelope detection of the ASK modulated signal. The sub-threshold operation and low-supply-voltage are used extensively in the analog design—to keep the power consumption low. The IC was fabricated using 0.18 μm CMOS technology in a die area of 1.5 mm × 1.5 mm and an effective area of 0.7 mm2. The minimum supply voltage desired is 1.2 V, for which the total power consumption is 107 μW. The analog part of the design consumes only 36 μW, which is low in comparison to other contemporary passive tags ICs. Eventually, a passive tag is developed using the frontend IC, a microcontroller, a temperature and a pressure sensor. A smart NFC device is used to readout the sensor data from the tag employing an Android-based application software. The measurement results demonstrate the full passive operational capability. The IC is suitable for low-power and low-cost industrial or biomedical battery-less sensor applications. A figure-of-merit (FOM) is proposed in this paper which is taken as a reference for comparison with other related state-of-the-art researches. PMID:29735939
Ion-neutral Coupling During Deep Solar Minimum
NASA Technical Reports Server (NTRS)
Huang, Cheryl Y.; Roddy, Patrick A.; Sutton, Eric K.; Stoneback, Russell; Pfaff, Robert F.; Gentile, Louise C.; Delay, Susan H.
2013-01-01
The equatorial ionosphere under conditions of deep solar minimum exhibits structuring due to tidal forces. Data from instruments carried by the Communication Navigation Outage Forecasting System (CNOFS) which was launched in April 2008 have been analyzed for the first 2 years following launch. The Planar Langmuir Probe (PLP), Ion Velocity Meter (IVM) and Vector Electric Field Investigation (VEFI) all detect periodic structures during the 20082010 period which appear to be tides. However when the tidal features detected by these instruments are compared, there are distinctive and significant differences between the observations. Tides in neutral densities measured by the Gravity Recovery and Climate Experiment (GRACE) satellite were also observed during June 2008. In addition, Broad Plasma Decreases (BPDs) appear as a deep absolute minimum in the plasma and neutral density tidal pattern. These are co-located with regions of large downward-directed ion meridional velocities and minima in the zonal drifts, all on the nightside. The region in which BPDs occur coincides with a peak in occurrence rate of dawn depletions in plasma density observed on the Defense Meterological Satellite Program (DMSP) spacecraft, as well as a minimum in radiance detected by UV imagers on the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) and IMAGE satellites
Characterization of Terahertz Bi-Material Sensors with Integrated Metamaterial Absorbers
2013-09-01
Kumar, Qing Hu, and J. L. Reno, “Real-time imaging using a 4.3-THz quantum cascade laser and a 320x240 microbolometer focal-plane array ,” IEEE...responsivity, the speed of operation and the minimum detected incident power were measured using a quantum cascade laser (QCL), operating at 3.8 THz...of operation and the minimum detected incident power were measured using a quantum cascade laser (QCL), operating at 3.8 THz. The measured
Minimum Error Bounded Efficient L1 Tracker with Occlusion Detection (PREPRINT)
2011-01-01
Minimum Error Bounded Efficient `1 Tracker with Occlusion Detection Xue Mei\\ ∗ Haibin Ling† Yi Wu†[ Erik Blasch‡ Li Bai] \\Assembly Test Technology...proposed BPR-L1 tracker is tested on several challenging benchmark sequences involving chal- lenges such as occlusion and illumination changes. In all...point method de - pends on the value of the regularization parameter λ. In the experiments, we found that the total number of PCG is a few hundred. The
[Severe spotted fever by Rickettsia rickettsii, in tourist in the Argentine Northwest].
Seijo, Alfredo; Giamperetti, Sergio; Ortiz Mayor, Sonia M; González, María B; Ortega, Eugenia S; González, Rossana C
On the fifth day after leaving the Parque Nacional El Rey, province of Salta, Argentina, where she made rural tourism, a woman of Italian origin, aged 47, developed an acute fever followed by a petechial and purpuric rash that progressed rapidly to multiorgan failure. She died on the sixth day after hospitalization. There were references to tick bites and a skin lesion similar to tache noire was found. The autopsy showed generalized vasculitis, ascites, pulmonary edema, acute tubular necrosis and portal centrilobular necrosis. Spleen and liver tissue were processed for PCR Rickettsia spp, based on the detection of the gltA gene. The result was positive. The amplicons obtained were sequenced and the results were compared with the preset sequences on the BLAST program, 99% coinciding with R. rickettsii. The low sensitivity of the health system to recognize this disease and the insufficient information generated from tourism-related media are factors that affect the delay to implement effective treatment and appropriate prevention standards.
A family of neuromuscular stimulators with optical transcutaneous control.
Jarvis, J C; Salmons, S
1991-01-01
A family of miniature implantable neuromuscular stimulators has been developed using surface-mounted Philips 4000-series integrated circuits. The electronic components are mounted by hand on printed circuits (platinum/gold on alumina) and the electrical connections are made by reflow soldering. The plastic integrated-circuit packages, ceramic resistors and metal interconnections are protected from the body fluids by a coating of biocompatible silicone rubber. This simple technology provides reliable function for at least 4 months under implanted conditions. The circuits have in common a single lithium cell power-supply (3.2 V) and an optical sensor which can be used to detect light flashes through the skin after the device has been implanted. This information channel may be used to switch the output of a device on or off, or to cycle through a series of pre-set programs. The devices are currently finding application in studies which provide an experimental basis for the clinical exploitation of electrically stimulated skeletal muscle in cardiac assistance, sphincter reconstruction or functional electrical stimulation of paralysed limbs.
Real-time sensing and gas jet mitigation of VDEs on Alcator C-Mod
NASA Astrophysics Data System (ADS)
Granetz, R. S.; Wolfe, S. M.; Izzo, V. A.; Reinke, M. L.; Terry, J. L.; Hughes, J. W.; Zhurovich, K.; Whyte, D. G.; Bakhtiari, M.; Wurden, G.
2006-10-01
Experiments have been carried out in Alcator C-Mod to test the effectiveness of gas jet disruption mitigation of VDEs with real-time detection and triggering by the C-Mod digital plasma control system (DPCS). The DPCS continuously computes the error in the plasma vertical position from the magnetics diagnostics. When this error exceeds an adjustable preset value, the DPCS triggers the gas jet valve (with a negligible latency time). The high-pressure gas (argon) only takes a few milliseconds to enter the vacuum chamber and begin affecting the plasma, but this is comparable to the VDE timescale on C-Mod. Nevertheless, gas jet injection reduced the halo current, increased the radiated power fraction, and reduced the heating of the divertor compared to unmitigated disruptions, but not quite as well as in earlier mitigation experiments with vertically stable plasmas. Presumably a faster overall response time would be beneficial, and several ways to achieve this will also be discussed.
Setting a disordered password on a photonic memory
NASA Astrophysics Data System (ADS)
Su, Shih-Wei; Gou, Shih-Chuan; Chew, Lock Yue; Chang, Yu-Yen; Yu, Ite A.; Kalachev, Alexey; Liao, Wen-Te
2017-06-01
An all-optical method of setting a disordered password on different schemes of photonic memory is theoretically studied. While photons are regarded as ideal information carriers, it is imperative to implement such data protection on all-optical storage. However, we wish to address the intrinsic risk of data breaches in existing schemes of photonic memory. We theoretically demonstrate a protocol using spatially disordered laser fields to encrypt data stored on an optical memory, namely, encrypted photonic memory. To address the broadband storage, we also investigate a scheme of disordered echo memory with a high fidelity approaching unity. The proposed method increases the difficulty for the eavesdropper to retrieve the stored photon without the preset password even when the randomized and stored photon state is nearly perfectly cloned. Our results pave ways to significantly reduce the exposure of memories, required for long-distance communication, to eavesdropping and therefore restrict the optimal attack on communication protocols. The present scheme also increases the sensitivity of detecting any eavesdropper and so raises the security level of photonic information technology.
Minimum requirements for adequate nighttime conspicuity of highway signs
DOT National Transportation Integrated Search
1988-02-01
A laboratory and field study were conducted to assess the minimum luminance levels of signs to ensure that they will be detected and identified at adequate distances under nighttime driving conditions. A total of 30 subjects participated in the field...
Mann, L.J.
1989-01-01
Concern has been expressed that some of the approximately 30,900 curies of tritium disposed to the Snake River Plain aquifer from 1952 to 1988 at the INEL (Idaho National Engineering Laboratory) have migrated to springs discharging to the Snake River in the Twin Falls-Hagerman area. To document tritium concentrations in springflow, 17 springs were sampled in November 1988 and 19 springs were sampled in March 1989. Tritium concentrations were less than the minimum detectable concentration of 0.5 pCi/mL (picocuries/mL) in November 1988 and less than the minimum detectable concentration of 0.2 pCi/mL in March 1989; the minimum detectable concentration was smaller in March 1989 owing to a longer counting time in the liquid scintillation system. The maximum contaminant level of tritium in drinking water as established by the U.S. Environmental Protection Agency is 20 pCi/mL. U.S. Environmental Protection Agency sample analyses indicate that the tritium concentration has decreased in the Snake River near Buhl since the 1970's. In 1974-79, tritium concentrations were less than 0.3 +/-0.2 pCi/mL in 3 of 20 samples; in 1983-88, 17 of 23 samples contained less than 0.3 +/-0.2 pCi/mL of tritium; the minimum detectable concentration is 0.2 pCi/mL. On the basis of decreasing tritium concentrations in the Snake River, their correlation to cessation of atmospheric weapons tests tritium concentrations in springflow less than the minimum detectable concentration, and the distribution of tritium in groundwater at the INEL, aqueous disposal of tritium at the INEL has had no measurable effect on tritium concentrations in springflow from the Snake River Plain aquifer and in the Snake River near Buhl. (USGS)
USDA-ARS?s Scientific Manuscript database
Background Maize exhibits a wealth of epigenetic phenomena, from transposon silencing, cycling and presetting, to gene imprinting and paramutation. Furthermore, despite the complexity and sophistication of maize breeding, there is a large degree of “hidden” variation for many traits that is difficul...
GAP Noise Computation By The CE/SE Method
NASA Technical Reports Server (NTRS)
Loh, Ching Y.; Chang, Sin-Chung; Wang, Xiao Y.; Jorgenson, Philip C. E.
2001-01-01
A typical gap noise problem is considered in this paper using the new space-time conservation element and solution element (CE/SE) method. Implementation of the computation is straightforward. No turbulence model, LES (large eddy simulation) or a preset boundary layer profile is used, yet the computed frequency agrees well with the experimental one.
Virtual Worlds, Virtual Literacy: An Educational Exploration
ERIC Educational Resources Information Center
Stoerger, Sharon
2008-01-01
Virtual worlds enable students to learn through seeing, knowing, and doing within visually rich and mentally engaging spaces. Rather than reading about events, students become part of the events through the adoption of a pre-set persona. Along with visual feedback that guides the players' activities and the development of visual skills, visual…
ERIC Educational Resources Information Center
Cunningham, Thomas H.; Parnell, Gary L.
2007-01-01
Democratic professional development is of the teachers, by the teachers, for the teachers. It differs from managerial models, which often have preset agendas and provide what "experts" think teachers need. Managerial models tend to be leader-centered, making some teachers feel treated like "tall children" rather than…
Inclusive Education: Practical Implementation of the Least Restrictive Environment.
ERIC Educational Resources Information Center
Power-deFur, Lissa A.; Orelove, Fred P.
The 19 chapters of this book address theoretical and practical aspects of the development and implementation of inclusive education programs. Chapter titles and authors are: (1) "Inclusive Education: The Past, Preset, and Future" (Lissa A. Power-deFur and Fred P. Orelove); (2) "Inclusion and School Restructuring: Meeting the Needs of All Children"…
Soft-Starting Power-Factor Motor Controller
NASA Technical Reports Server (NTRS)
Nola, F. J.
1983-01-01
Three-phase power-factor controller with soft start is based on earlier version that does not control starting transients. Additional components serve to turn off "run" command signal and substitute gradual startup command signal during preset startup interval. Improved controller reduces large current surge that usually accompanies starting. Controller applies power smoothly, without causing motor vibrations.
Free Sixteen Harmonic Fourier Series Web App with Sound
ERIC Educational Resources Information Center
Ruiz, Michael J.
2018-01-01
An online HTML5 Fourier synthesizer app is provided that allows students to manipulate sixteen harmonics and construct periodic waves. Students can set the amplitudes and phases for each harmonic, seeing the resulting waveforms and hearing the sounds. Five waveform presets are included: sine, triangle, square, ramp (sawtooth), and pulse train. The…
Aerodynamic design using numerical optimization
NASA Technical Reports Server (NTRS)
Murman, E. M.; Chapman, G. T.
1983-01-01
The procedure of using numerical optimization methods coupled with computational fluid dynamic (CFD) codes for the development of an aerodynamic design is examined. Several approaches that replace wind tunnel tests, develop pressure distributions and derive designs, or fulfill preset design criteria are presented. The method of Aerodynamic Design by Numerical Optimization (ADNO) is described and illustrated with examples.
Thermodynamical Interactions: Subtleties of Heat and Work Concepts
ERIC Educational Resources Information Center
Anacleto, Joaquim; Anacleto, Joaquim Alberto C.
2008-01-01
This paper focuses on the determination of the final equilibrium state when two ideal gases, isolated from the exterior and starting from preset initial conditions, interact with each other through a piston. Depending on the piston properties, different processes take place and also different sets of equilibrium conditions must be satisfied. Three…
Starting Silicon-Ribbon Growth Automatically
NASA Technical Reports Server (NTRS)
Mchugh, J. P.
1984-01-01
Semiautomatic system starts growth of silicon sheets more reliably than system with purely manual control. Control signals for starting sheetcrystal growth consist of ramps (during which signal changes linearly from one value to another over preset time interval) and soaks (during which signal remains constant). Ramps and soaks for best temperature and pulling speed determined by experimentation.
ERIC Educational Resources Information Center
Green, Sharon; Grierson, Lawrence E. M.; Dubrowski, Adam; Carnahan, Heather
2010-01-01
It is well known that sensorimotor memories are built and updated through experience with objects. These representations are useful to anticipatory and feedforward control processes that preset grip and load forces during lifting. When individuals lift objects with qualities that are not congruent with their memory-derived expectations, feedback…
Measurements and Analysis of 115 KV Power Line Noise and Its Effect on Pueblo Test Site Radio Links
DOT National Transportation Integrated Search
1972-05-01
Noise measurements were made for 115 KV power lines near the frequencies 166, 217 and 406.8 MHz with a receiver bandwidth of 1 MHz. The measurements consisted of counting the numbers of pulses per minute at preset threshold values and RMS. The variat...
On the possibility of control restoration in some inverse problems of heat and mass transfer
NASA Astrophysics Data System (ADS)
Bilchenko, G. G.; Bilchenko, N. G.
2016-11-01
The hypersonic aircraft permeable surfaces effective heat protection problems are considered. The physic-chemical processes (the dissociation and the ionization) in laminar boundary layer of compressible gas are appreciated in mathematical model. The statements of direct problems of heat and mass transfer are given: according to preset given controls it is necessary to compute the boundary layer mathematical model parameters and determinate the local and total heat flows and friction forces and the power of blowing system. The A.A.Dorodnicyn's generalized integral relations method has been used as calculation basis. The optimal control - the blowing into boundary layer (for continuous functions) was constructed as the solution of direct problem in extreme statement with the use of this approach. The statement of inverse problems are given: the control laws ensuring the preset given local heat flow and local tangent friction are restored. The differences between the interpolation and the approximation statements are discussed. The possibility of unique control restoration is established and proved (in the stagnation point). The computational experiments results are presented.
Optimization of valve opening process for the suppression of impulse exhaust noise
NASA Astrophysics Data System (ADS)
Li, Jingxiang; Zhao, Shengdun
2017-02-01
Impulse exhaust noise generated by the sudden impact of discharging flow of pneumatic systems has significant temporal characteristics including high sound pressure and rapid sound transient. The impulse noise exposures are more hazardous to hearing than the energy equivalent uniform noise exposures. This paper presents a novel approach to suppress the peak sound pressure as a major indicator of impulsiveness of the impulse exhaust noise by an optimization of the opening process of valve. Relationships between exhaust flow and impulse noise are described by thermodynamics and noise generating mechanism. Then an optimized approach by controlling the valve opening process is derived under a constraint of pre-setting exhaust time. A modified servo-direct-driven valve was designed and assembled in a typical pneumatic system for the verification experiments comparing with an original solenoid valve. Experimental results with groups of initial cylinder pressures and pre-setting exhaust times are shown to verify the effects of the proposed optimization. Some indicators of energy-equivalent and impulsiveness are introduced to discuss the effects of the noise suppressions. Relationship between noise reduction and exhaust time delay is also discussed.
NASA Astrophysics Data System (ADS)
Kraeuchi, Andreas; Philipona, Rolf
2015-04-01
Very promising radiation profile measurements through the atmosphere were made in 2011 with a balloon borne short- and longwave net radiometer. New and improved radiation sensors from Kipp&Zonen are now used in a glider aircraft together with a standard Swiss radiosonde from Meteolabor AG. This new return glider radiosonde (RG-R), is lifted up with double balloon technique to prevent pendulum motion and to keep the radiation instruments as horizontal as possible during the ascent measuring phase. The RG-R is equipped with a mechanism that allows to release the radiosonde at a preset altitude, and an autopilot allowing to fly the radiosonde back to the launch site and to land it savely with a parachute at a preset location. The return glider radiosonde technique as well as new measurement possibilities will be shown. First measurements show temperature, humidity and radiation profiles through the atmosphere up to 30 hPa (24 km) during different atmospheric conditions. Radiation profiles during different daytimes show possibilities with respect to temporal resolution of vertical radiation profiles trough the atmosphere.
Big Data Toolsets to Pharmacometrics: Application of Machine Learning for Time-to-Event Analysis.
Gong, Xiajing; Hu, Meng; Zhao, Liang
2018-05-01
Additional value can be potentially created by applying big data tools to address pharmacometric problems. The performances of machine learning (ML) methods and the Cox regression model were evaluated based on simulated time-to-event data synthesized under various preset scenarios, i.e., with linear vs. nonlinear and dependent vs. independent predictors in the proportional hazard function, or with high-dimensional data featured by a large number of predictor variables. Our results showed that ML-based methods outperformed the Cox model in prediction performance as assessed by concordance index and in identifying the preset influential variables for high-dimensional data. The prediction performances of ML-based methods are also less sensitive to data size and censoring rates than the Cox regression model. In conclusion, ML-based methods provide a powerful tool for time-to-event analysis, with a built-in capacity for high-dimensional data and better performance when the predictor variables assume nonlinear relationships in the hazard function. © 2018 The Authors. Clinical and Translational Science published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.
Thomas-Gibson, Siwan; Bugajski, Marek; Bretthauer, Michael; Rees, Colin J; Dekker, Evelien; Hoff, Geir; Jover, Rodrigo; Suchanek, Stepan; Ferlitsch, Monika; Anderson, John; Roesch, Thomas; Hultcranz, Rolf; Racz, Istvan; Kuipers, Ernst J; Garborg, Kjetil; East, James E; Rupinski, Maciej; Seip, Birgitte; Bennett, Cathy; Senore, Carlo; Minozzi, Silvia; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Spada, Cristiano; Hassan, Cesare; Dinis-Ribeiro, Mario; Rutter, Matthew D
2017-01-01
The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level: 1 rate of adequate bowel preparation (minimum standard 90%); 2 cecal intubation rate (minimum standard 90%); 3 adenoma detection rate (minimum standard 25%); 4 appropriate polypectomy technique (minimum standard 80%); 5 complication rate (minimum standard not set); 6 patient experience (minimum standard not set); 7 appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures. PMID:28507745
Epilepsy: some controversies, some knowledge and some experience from Cambodia.
Hun, Chamroeun; Hok, Tola; Ros, Sina; Chan, Samleng; Bhalla, Devender
2014-01-01
Epilepsy-related health outcomes remain unacceptably low in much of the developing world. According to us, it is because of the failure since long to see, and address, epilepsy beyond its preset conventional image. The objective of this paper was to highlight the presence, and influence, of these conventional practices and also to demonstrate what happened when a bold unconventional approach to address epilepsy was taken in Cambodia. Data are taken from existing published literature on epilepsy as well as our field experience during several population-based surveys conducted in Cambodia. We complimented this with our knowledge gained over this long period. It is demonstrated that epilepsy is far more important in Asia that it is currently considered to be, and also vis-à-vis other geographic regions. Pregnancy and birth-related factors carry far higher odds for epilepsy than several "highly vocal" infections. A refocus in epilepsy is required to help move from its traditional negative image to an image where epilepsy is considered a "positive-looking" disorder that is full of "opportunities;" such as availability of safe effective inexpensive treatment, etc. Stigma is a two-side entity (i.e., it is present, and it is influential), and diligence should be therefore practiced before using the stigma label. Nevertheless, psychosocial aspects shouldn't be limited to stigma or Jacoby stigma scale alone. Quality of life is a subjective phenomenon, and patients should determine directly what affects them. It is highly desirable that if we want to find newer answers to old problems in epilepsy, we need to shed our conventional approach and preset conclusions. We should choose to move toward "opportunities" visibly present in epilepsy. Our Cambodian experience demonstrates more intimately that opportunities do get identified when preset conclusions are questioned, and an approach that goes beyond expected and by default is taken.
Non-invasive timing of gas gun projectiles with light detection and ranging
NASA Astrophysics Data System (ADS)
Goodwin, P. M.; Bartram, B. D.; Gibson, L. L.; Wu, M.; Dattelbaum, D. M.
2014-05-01
We have developed a Light Detection and Ranging (LIDAR) diagnostic to track the position of a projectile inside of a gas gun launch tube in real-time. This capability permits the generation of precisely timed trigger pulses useful for triggering high-latency diagnostics such as a flash lamp-pumped laser. An initial feasibility test was performed using a 72 mm bore diameter single-stage gas gun routinely used for dynamic research at Los Alamos. A 655 nm pulsed diode laser operating at a pulse repetition rate of 100 kHz was used to interrogate the position of the moving projectile in real-time. The position of the projectile in the gun barrel was tracked over a distance of ~ 3 meters prior to impact. The position record showed that the projectile moved at a velocity of 489 m/s prior to impacting the target. This velocity was in good agreement with independent measurements of the projectile velocity by photon Doppler velocimetry and timing of the passage of the projectile through optical marker beams positioned at the muzzle of the gun. The time-to-amplitude conversion electronics used enable the LIDAR data to be processed in real-time to generate trigger pulses at preset separations between the projectile and target.
Xiang, Kun; Li, Yinglei; Ford, William; Land, Walker; Schaffer, J David; Congdon, Robert; Zhang, Jing; Sadik, Omowunmi
2016-02-21
We hereby report the design and implementation of an Autonomous Microbial Cell Culture and Classification (AMC(3)) system for rapid detection of food pathogens. Traditional food testing methods require multistep procedures and long incubation period, and are thus prone to human error. AMC(3) introduces a "one click approach" to the detection and classification of pathogenic bacteria. Once the cultured materials are prepared, all operations are automatic. AMC(3) is an integrated sensor array platform in a microbial fuel cell system composed of a multi-potentiostat, an automated data collection system (Python program, Yocto Maxi-coupler electromechanical relay module) and a powerful classification program. The classification scheme consists of Probabilistic Neural Network (PNN), Support Vector Machines (SVM) and General Regression Neural Network (GRNN) oracle-based system. Differential Pulse Voltammetry (DPV) is performed on standard samples or unknown samples. Then, using preset feature extractions and quality control, accepted data are analyzed by the intelligent classification system. In a typical use, thirty-two extracted features were analyzed to correctly classify the following pathogens: Escherichia coli ATCC#25922, Escherichia coli ATCC#11775, and Staphylococcus epidermidis ATCC#12228. 85.4% accuracy range was recorded for unknown samples, and within a shorter time period than the industry standard of 24 hours.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fournier, Sean Donovan; Beall, Patrick S; Miller, Mark L
2014-08-01
Through the SNL New Mexico Small Business Assistance (NMSBA) program, several Sandia engineers worked with the Environmental Restoration Group (ERG) Inc. to verify and validate a novel algorithm used to determine the scanning Critical Level (L c ) and Minimum Detectable Concentration (MDC) (or Minimum Detectable Areal Activity) for the 102F scanning system. Through the use of Monte Carlo statistical simulations the algorithm mathematically demonstrates accuracy in determining the L c and MDC when a nearest-neighbor averaging (NNA) technique was used. To empirically validate this approach, SNL prepared several spiked sources and ran a test with the ERG 102F instrumentmore » on a bare concrete floor known to have no radiological contamination other than background naturally occurring radioactive material (NORM). The tests conclude that the NNA technique increases the sensitivity (decreases the L c and MDC) for high-density data maps that are obtained by scanning radiological survey instruments.« less
King, Michael J.; Sanchez, Roberto J.; Moss, William C.
2013-03-19
A passive blast pressure sensor for detecting blast overpressures of at least a predetermined minimum threshold pressure. The blast pressure sensor includes a piston-cylinder arrangement with one end of the piston having a detection surface exposed to a blast event monitored medium through one end of the cylinder and the other end of the piston having a striker surface positioned to impact a contact stress sensitive film that is positioned against a strike surface of a rigid body, such as a backing plate. The contact stress sensitive film is of a type which changes color in response to at least a predetermined minimum contact stress which is defined as a product of the predetermined minimum threshold pressure and an amplification factor of the piston. In this manner, a color change in the film arising from impact of the piston accelerated by a blast event provides visual indication that a blast overpressure encountered from the blast event was not less than the predetermined minimum threshold pressure.
ERIC Educational Resources Information Center
Fastre, Greet Mia Jos; van der Klink, Marcel R.; van Merrienboer, Jeroen J. G.
2010-01-01
This study investigated the effect of performance-based versus competence-based assessment criteria on task performance and self-assessment skills among 39 novice secondary vocational education students in the domain of nursing and care. In a performance-based assessment group students are provided with a preset list of performance-based…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... discretion to the member organizations to define pre-set risk thresholds. The tools are designed to act as a... comments more efficiently, please use only one method. The Commission will post all comments on the... To Offer Risk Management Tools Designed To Allow Member Organizations To Monitor and Address Exposure...
NASA Technical Reports Server (NTRS)
1996-01-01
In order to more easily join the huge sections of the Space Shuttle external tank, Marshall Space Flight Center initiated development of the existing concept of Variable Polarity Plasma Arc (VPPA) welding. VPPA welding employs a variable current waveform that allows the system to operate for preset time increments in either of two polarity modes for effective joining of light alloys.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-03
... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-70946; File No. SR-NSCC-2013-12] Self... Activity and Receive Notifications When Pre-Set Trading Limits are Reached November 26, 2013. Pursuant to Section 19(b)(1) of the Securities Exchange Act of 1934 (``Act'') \\1\\ and Rule 19b-4 thereunder,\\2\\ notice...
1996-01-01
In order to more easily join the huge sections of the Space Shuttle external tank, Marshall Space Flight Center initiated development of the existing concept of Variable Polarity Plasma Arc (VPPA) welding. VPPA welding employs a variable current waveform that allows the system to operate for preset time increments in either of two polarity modes for effective joining of light alloys.
Instrument for the measurement and determination of chemical pulse column parameters
Marchant, Norman J.; Morgan, John P.
1990-01-01
An instrument for monitoring and measuring pneumatic driving force pulse parameters applied to chemical separation pulse columns obtains real time pulse frequency and root mean square amplitude values, calculates column inch values and compares these values against preset limits to alert column operators to the variations of pulse column operational parameters beyond desired limits.
[Supplementary device for a dynamometer to evaluate and register muscular endurance indices].
Timoshenko, D A; Bokser, O Ia
1986-01-01
In practice of psychophysiologic research muscular endurance index is used for estimation of CNS function. Muscular endurance index is defined as relative time needed for maintaining the preset muscular effort. The described device widens the possibilities of a digital dynamometer for automatic estimation and recording of muscular endurance index in real time.
Code of Federal Regulations, 2011 CFR
2011-01-01
... defrost control. The energy consumption in kilowatt-hours per day shall be calculated equivalent to: ET... though the consumer-activated compartment temperature controls were preset so that the desired... calculated effect of operating a freezer for a period of 24 hours with the consumer-activated controls other...
76 FR 38293 - Risk Management Controls for Brokers or Dealers With Market Access
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
... securities to give broker- dealers with market access additional time to develop, test, and implement the... that exceed appropriate pre-set credit or capital thresholds,\\5\\ or that appear to be erroneous.\\6\\ The... satisfied on a pre-order entry basis,\\7\\ prevent the entry of orders that the broker- dealers or customer is...
77 FR 51807 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-27
... Minimum Data Elements (MDEs) for the National Breast and Cervical Cancer Early Detection Program (NBCCEDP... screening and early detection tests for breast and cervical cancer. Mammography is extremely valuable as an early detection tool because it can detect breast cancer well before the woman can feel the lump, when...
Real-time alkali monitoring system
Goff, David R.; Romanosky, Robert R.; Hensel, Peter
1990-01-01
A fiber optics based optical emission line monitoring system is provided in which selected spectral emission lines, such as the sodium emission line, may be detected in the presence of interfering background radiation. A combustion flame is fed by a diverted portion of a process stream and the common end of a bifurcated or quadfurcated fiber optic light guide is adapted to collect light from the flame. The light is guided through the branches of the fiber optic cable to bandpass filters, one of which is adapted to each of the branches of the fiber optic light guide. The bandpass filters are centered at wavelengths corresponding to the emission lines to be detected and two separate filters are required for each species being detected. The first filter has a bandwidth of about 3 nms and the second filter has a bandwidth of about 10 nms. Light detectors are located to view the light passing through the bandpass filters and amplifiers are connected to receive signals from the light detectors. The amplifier corresponding to the bandpass filter having the narrower bandwidth is preset to scale the signal by a factor equal to the ratio of the wide and narrow bandwidths of the bandpass filters. This scaling produces a scaled signal from which the difference between the scaled signal on the other signal can be calculated to produce a signal having an amplitude directly proportional to the concentration of the species of interest and independent of background radiation.
The investigation of solar activity signals by analyzing of tree ring chronological scales
NASA Astrophysics Data System (ADS)
Nickiforov, M. G.
2017-07-01
The present study examines the ability of detecting short-cycles and global minima of solar activity by analyzing dendrochronologies. Starting with the study of Douglass, which was devoted to the question of climatic cycles and the growth of trees, it is believed that the analysis of dendrochronologies allows to detect the cycle of Wolf-Schwabe. According to his results, the cycle was absent during Maunder's minimum and appeared after its completion. Having checked Douglass's conclusions by using 10 dendrochronologies of yellow pines from Arizona, which cover the time period from 1600 to 1900, we have come to the opposite results. The verification shows that: a) none of the considered dendroscale allows to detect an 11-year cycle; 2) the behaviour of a short peroid-signal does not undergo significant changes before, during or after Maunder's minimum. A similar attempt to detect global minima of solar activity by using five dendrochronologies from different areas has not led to positive results. On the one hand, the signal of global extremum is not always recorded in dendrochronology, on the other hand, the deep depression of annual rings allows to suppose the existence of a global minimum of solar activity, which is actually absent.
50 CFR 218.174 - Requirements for monitoring and reporting.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-based surveys shall be designed to maximize detections of marine mammals near mission activity event. (2... Navy to implement, at a minimum, the monitoring activities summarized below: (1) Visual Surveys: (i) The Holder of this Authorization shall conduct a minimum of 2 special visual surveys per year to...
Zhou, L; Qu, Z G; Ding, T; Miao, J Y
2016-04-01
The gas-solid adsorption process in reconstructed random porous media is numerically studied with the lattice Boltzmann (LB) method at the pore scale with consideration of interparticle, interfacial, and intraparticle mass transfer performances. Adsorbent structures are reconstructed in two dimensions by employing the quartet structure generation set approach. To implement boundary conditions accurately, all the porous interfacial nodes are recognized and classified into 14 types using a proposed universal program called the boundary recognition and classification program. The multiple-relaxation-time LB model and single-relaxation-time LB model are adopted to simulate flow and mass transport, respectively. The interparticle, interfacial, and intraparticle mass transfer capacities are evaluated with the permeability factor and interparticle transfer coefficient, Langmuir adsorption kinetics, and the solid diffusion model, respectively. Adsorption processes are performed in two groups of adsorbent media with different porosities and particle sizes. External and internal mass transfer resistances govern the adsorption system. A large porosity leads to an early time for adsorption equilibrium because of the controlling factor of external resistance. External and internal resistances are dominant at small and large particle sizes, respectively. Particle size, under which the total resistance is minimum, ranges from 3 to 7 μm with the preset parameters. Pore-scale simulation clearly explains the effect of both external and internal mass transfer resistances. The present paper provides both theoretical and practical guidance for the design and optimization of adsorption systems.
NASA Astrophysics Data System (ADS)
Zhou, L.; Qu, Z. G.; Ding, T.; Miao, J. Y.
2016-04-01
The gas-solid adsorption process in reconstructed random porous media is numerically studied with the lattice Boltzmann (LB) method at the pore scale with consideration of interparticle, interfacial, and intraparticle mass transfer performances. Adsorbent structures are reconstructed in two dimensions by employing the quartet structure generation set approach. To implement boundary conditions accurately, all the porous interfacial nodes are recognized and classified into 14 types using a proposed universal program called the boundary recognition and classification program. The multiple-relaxation-time LB model and single-relaxation-time LB model are adopted to simulate flow and mass transport, respectively. The interparticle, interfacial, and intraparticle mass transfer capacities are evaluated with the permeability factor and interparticle transfer coefficient, Langmuir adsorption kinetics, and the solid diffusion model, respectively. Adsorption processes are performed in two groups of adsorbent media with different porosities and particle sizes. External and internal mass transfer resistances govern the adsorption system. A large porosity leads to an early time for adsorption equilibrium because of the controlling factor of external resistance. External and internal resistances are dominant at small and large particle sizes, respectively. Particle size, under which the total resistance is minimum, ranges from 3 to 7 μm with the preset parameters. Pore-scale simulation clearly explains the effect of both external and internal mass transfer resistances. The present paper provides both theoretical and practical guidance for the design and optimization of adsorption systems.
NASA Astrophysics Data System (ADS)
Tehsin, Sara; Rehman, Saad; Riaz, Farhan; Saeed, Omer; Hassan, Ali; Khan, Muazzam; Alam, Muhammad S.
2017-05-01
A fully invariant system helps in resolving difficulties in object detection when camera or object orientation and position are unknown. In this paper, the proposed correlation filter based mechanism provides the capability to suppress noise, clutter and occlusion. Minimum Average Correlation Energy (MACE) filter yields sharp correlation peaks while considering the controlled correlation peak value. Difference of Gaussian (DOG) Wavelet has been added at the preprocessing stage in proposed filter design that facilitates target detection in orientation variant cluttered environment. Logarithmic transformation is combined with a DOG composite minimum average correlation energy filter (WMACE), capable of producing sharp correlation peaks despite any kind of geometric distortion of target object. The proposed filter has shown improved performance over some of the other variant correlation filters which are discussed in the result section.
Kang, Sinkyu; Hong, Suk Young
2016-01-01
A minimum composite method was applied to produce a 15-day interval normalized difference vegetation index (NDVI) dataset from Moderate Resolution Imaging Spectroradiometer (MODIS) daily 250 m reflectance in the red and near-infrared bands. This dataset was applied to determine lake surface areas in Mongolia. A total of 73 lakes greater than 6.25 km2in area were selected, and 28 of these lakes were used to evaluate detection errors. The minimum composite NDVI showed a better detection performance on lake water pixels than did the official MODIS 16-day 250 m NDVI based on a maximum composite method. The overall lake area detection performance based on the 15-day minimum composite NDVI showed -2.5% error relative to the Landsat-derived lake area for the 28 evaluated lakes. The errors increased with increases in the perimeter-to-area ratio but decreased with lake size over 10 km2. The lake area decreased by -9.3% at an annual rate of -53.7 km2 yr-1 during 2000 to 2011 for the 73 lakes. However, considerable spatial variations, such as slight-to-moderate lake area reductions in semi-arid regions and rapid lake area reductions in arid regions, were also detected. This study demonstrated applicability of MODIS 250 m reflectance data for biweekly monitoring of lake area change and diagnosed considerable lake area reduction and its spatial variability in arid and semi-arid regions of Mongolia. Future studies are required for explaining reasons of lake area changes and their spatial variability. PMID:27007233
Kang, Sinkyu; Hong, Suk Young
2016-01-01
A minimum composite method was applied to produce a 15-day interval normalized difference vegetation index (NDVI) dataset from Moderate Resolution Imaging Spectroradiometer (MODIS) daily 250 m reflectance in the red and near-infrared bands. This dataset was applied to determine lake surface areas in Mongolia. A total of 73 lakes greater than 6.25 km2in area were selected, and 28 of these lakes were used to evaluate detection errors. The minimum composite NDVI showed a better detection performance on lake water pixels than did the official MODIS 16-day 250 m NDVI based on a maximum composite method. The overall lake area detection performance based on the 15-day minimum composite NDVI showed -2.5% error relative to the Landsat-derived lake area for the 28 evaluated lakes. The errors increased with increases in the perimeter-to-area ratio but decreased with lake size over 10 km(2). The lake area decreased by -9.3% at an annual rate of -53.7 km(2) yr(-1) during 2000 to 2011 for the 73 lakes. However, considerable spatial variations, such as slight-to-moderate lake area reductions in semi-arid regions and rapid lake area reductions in arid regions, were also detected. This study demonstrated applicability of MODIS 250 m reflectance data for biweekly monitoring of lake area change and diagnosed considerable lake area reduction and its spatial variability in arid and semi-arid regions of Mongolia. Future studies are required for explaining reasons of lake area changes and their spatial variability.
Differential detection of Gaussian MSK in a mobile radio environment
NASA Technical Reports Server (NTRS)
Simon, M. K.; Wang, C. C.
1984-01-01
Minimum shift keying with Gaussian shaped transmit pulses is a strong candidate for a modulation technique that satisfies the stringent out-of-band radiated power requirements of the mobil radio application. Numerous studies and field experiments have been conducted by the Japanese on urban and suburban mobile radio channels with systems employing Gaussian minimum-shift keying (GMSK) transmission and differentially coherent reception. A comprehensive analytical treatment is presented of the performance of such systems emphasizing the important trade-offs among the various system design parameters such as transmit and receiver filter bandwidths and detection threshold level. It is shown that two-bit differential detection of GMSK is capable of offering far superior performance to the more conventional one-bit detection method both in the presence of an additive Gaussian noise background and Rician fading.
Differential detection of Gaussian MSK in a mobile radio environment
NASA Astrophysics Data System (ADS)
Simon, M. K.; Wang, C. C.
1984-11-01
Minimum shift keying with Gaussian shaped transmit pulses is a strong candidate for a modulation technique that satisfies the stringent out-of-band radiated power requirements of the mobil radio application. Numerous studies and field experiments have been conducted by the Japanese on urban and suburban mobile radio channels with systems employing Gaussian minimum-shift keying (GMSK) transmission and differentially coherent reception. A comprehensive analytical treatment is presented of the performance of such systems emphasizing the important trade-offs among the various system design parameters such as transmit and receiver filter bandwidths and detection threshold level. It is shown that two-bit differential detection of GMSK is capable of offering far superior performance to the more conventional one-bit detection method both in the presence of an additive Gaussian noise background and Rician fading.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... ETP Holder to define pre-set risk thresholds. The tools are designed to act as a backstop for ETP... one method. The Commission will post all comments on the Commission's Internet Web site ( http://www... Change To Offer Risk Management Tools Designed To Allow ETP Holders To Monitor and Address Exposure to...
ERIC Educational Resources Information Center
Lin, Jin-Ding; Lin, Pei-Ying; Lin, Lan-Ping; Hsu, Shang-Wei; Yen, Chia-Feng; Fang, Wen-Hui; Wu, Sheng-Ru; Chien, Wu-Chien; Loh, Ching-Hui; Chu, Cordia M.
2009-01-01
The aims of the preset study were to describe the profile of serum uric acid, the prevalence of hyperuricemia and its risk factors among children and adolescents with intellectual disabilities. We conducted a cross-sectional study of 941 children and adolescents with intellectual disabilities (aged 4-18 years) who participated in annual health…
Self-Cleaning Tubular-Membrane Module
NASA Technical Reports Server (NTRS)
Sarbolouki, M. N.
1983-01-01
Tubular membranes made self-cleaning with aid of flow reversing valve. Sponge balls scrub membrane surfaces as they travel inside membrane tubes. A four-way flow-reversal valve automatically reverses flow in tubes at preset intervals so sponge balls reciprocate along tubes. Baskets at ends of tubes prevent sponges from escaping. Automatic cleaning feature added to existing membrane processing equipment with minimal modifications.
ERIC Educational Resources Information Center
Dósa, Katalin; Russ, Rosemary
2016-01-01
Learning in higher education today is measured overwhelmingly on the basis of "correctness," that is, whether students sufficiently approached the preset "expert" answer to a test question. We posit that although conceptual correctness is at the core of good learning, there is much information instructors miss out on by relying…
Improved Controllers For Heaters In Toxic-Gas Combustors
NASA Technical Reports Server (NTRS)
Wishard, James; Lamb, James; Fortier, Edward; Velasquez, Hugo; Waltman, Doug
1995-01-01
Commercial electronic proportional controllers installed in place of mechanical power controllers for electric heaters in toxic-gas combustors at NASA's Jet Propulsion Laboratory. Designed to maintain temperature of heater at preset value by turning power fully on or fully off when temperature falls below or rises above that value, respectively. Solid-state power controllers overcome deficiencies of mechanical power controllers.
Measuring Thicknesses of Wastewater Films
NASA Technical Reports Server (NTRS)
Schubert, F. H.; Davenport, R. J.
1987-01-01
Sensor determines when thickness of film of electrically conductive wastewater on rotating evaporator drum exceeds preset value. Sensor simple electrical probe that makes contact with liquid surface. Made of materials resistant to chemicals in liquid. Mounted on shaft in rotating cylinder, liquid-thickness sensor extends toward cylinder wall so tip almost touches. Sensor body accommodates probe measuring temperature of evaporated water in cylinder.
Functional differences in bi-level pressure preset ventilators.
Highcock, M P; Shneerson, J M; Smith, I E
2001-02-01
The performance of four bilevel positive pressure preset ventilators was compared. The ventilators tested were; BiPAP ST30 (Respironics); Nippy2 (B + D Electrical); Quantum PSV (Healthdyne); and Sullivan VPAP H ST (Resmed). A patient simulator was used to determine the sensitivity of the triggering mechanisms and the responses to a leak within the patient circuit, and to changes in patient effort. Significant differences (p <0.05) between the devices were seen in the trigger delay time and inspiratory trigger pressure. When a leak was introduced into the patient circuit, the fall in tidal volume (VT) was less than ten per cent for each ventilator. The addition of patient effort produced a number of changes in the ventilation delivered. Patient efforts of 0.25 s induced a variable fall in VT. An increase in VT was seen with some ventilators with patient efforts of 1 s but the effect was variable. Trigger failures and subsequent falls in minute volume were seen with the BiPAP and the Nippy2 at the highest respiratory frequency. Differences in the responses of the ventilators are demonstrated that may influence the selection of a ventilator, particularly in the treatment of breathless patients with ventilatory failure.
Identifying Interacting Genetic Variations by Fish-Swarm Logic Regression
Yang, Aiyuan; Yan, Chunxia; Zhu, Feng; Zhao, Zhongmeng; Cao, Zhi
2013-01-01
Understanding associations between genotypes and complex traits is a fundamental problem in human genetics. A major open problem in mapping phenotypes is that of identifying a set of interacting genetic variants, which might contribute to complex traits. Logic regression (LR) is a powerful multivariant association tool. Several LR-based approaches have been successfully applied to different datasets. However, these approaches are not adequate with regard to accuracy and efficiency. In this paper, we propose a new LR-based approach, called fish-swarm logic regression (FSLR), which improves the logic regression process by incorporating swarm optimization. In our approach, a school of fish agents are conducted in parallel. Each fish agent holds a regression model, while the school searches for better models through various preset behaviors. A swarm algorithm improves the accuracy and the efficiency by speeding up the convergence and preventing it from dropping into local optimums. We apply our approach on a real screening dataset and a series of simulation scenarios. Compared to three existing LR-based approaches, our approach outperforms them by having lower type I and type II error rates, being able to identify more preset causal sites, and performing at faster speeds. PMID:23984382
Programmable and Shape-Memorizing Information Carriers.
Li, Wenbing; Liu, Yanju; Leng, Jinsong
2017-12-27
Shape memory polymers (SMPs) are expected to play more and more important roles in space-deployable structures, smart actuators, and other high-tech areas. Nevertheless, because of the difficulties in fabrication and the programmability of temporary shape recovery, SMPs have not yet been widely applied in real fields. It is ideal to incorporate the different independent functional building blocks into a material. Herein, we designed a simple method to incorporate four functional building blocks: a neat epoxy-based shape memory (neat SMEP) resin, an SMEP composited with Fe 3 O 4 (SMEP-Fe 3 O 4 ), an SMEP composited with multiwalled carbon nanotubes, and an SMEP composited with p-aminodiphenylimide into a multicomposite, in which the four region surfaces could be programmed with different language code patterns according to a preset command by imprint lithography. Then, we aimed to reprogram the initially raised code patterns into temporary flat patterns using programming mold that, when triggered by a preset stimulus process such as an alternating magnetic field, radiofrequency field, 365 nm UV, and direct heating, could transform these language codes into the information passed by the customer. The concept introduced here will be applied to other available SMPs and provide a practical method to realize the information delivery.
Dynamically sculpturing plasmonic vortices: from integer to fractional orbital angular momentum
Wang, Yu; Zhao, Peng; Feng, Xue; Xu, Yuntao; Liu, Fang; Cui, Kaiyu; Zhang, Wei; Huang, Yidong
2016-01-01
As a fundamental tool for light-matter interactions, plasmonic vortex (PV) is extremely useful due to the unique near field property. However, it is a pity that, up to now, the orbital angular momentum (OAM) carried by PVs could not be dynamically and continuously tuned in practice as well as the properties of fractional PVs are still not well investigated. By comparing with two previously reported methods, it is suggested that our proposal of utilizing the propagation induced radial phase gradient of incident Laguerre-Gaussian (LG) beam is a promising candidate to sculpture PVs from integer to fractional OAM dynamically. Consequently, the preset OAM of PVs could have four composing parts: the incident spin and orbital angular momentum, the geometric contribution of chiral plasmonic structure, and the radial phase gradient dependent contribution. Moreover, an analytical expression for the fractional PV is derived as a linear superposition of infinite numbers of integer PVs described by Bessel function of the first kind. It is also shown that the actual mean OAM of a fractional PV would deviate from the preset value, which is similar with previous results for spatial fractional optical vortices. PMID:27811986
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Brett Emery Trabun; Gamage, Thoshitha Thanushka; Bakken, David Edward
This disclosure describes, in part, a system management component and failure detection component for use in a power grid data network to identify anomalies within the network and systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription. The failure detection component may identify an anomaly within the network and a source of the anomaly. Based on the identified anomaly, data rates and or datamore » paths may be adjusted in real-time to ensure that the power grid data network does not become overloaded and/or fail.« less
Venkatarajappa, P
2001-01-01
The toxic effect of Cypermethrin 10 EC (0.125, 0.25 and 0.5%) was estimated in the bodywall and digestive system of the larvae of Oryctes rhinoceros by HPLC after exposing them to different concentrations (0.125, 0.25 and 0.5%). Among the various concentrations used maximum residues were detected in bodywall (0.25%), whereas at higher concentration (0.5%) the residue detected was minimum. The treatment of Cypermethrin was found to be highly toxic upto 12 h of treatment, after which it declined reaching the minimum by 24 h. The residue of Cypermethrin could not be detected in digestive system. The experiments indicate the pesticide get concentrated in the bodywall to a maximum extent.
Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da
2016-04-01
A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. Copyright © 2016 Elsevier Ltd. All rights reserved.
Dual Energy Method for Breast Imaging: A Simulation Study.
Koukou, V; Martini, N; Michail, C; Sotiropoulou, P; Fountzoula, C; Kalyvas, N; Kandarakis, I; Nikiforidis, G; Fountos, G
2015-01-01
Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNR tc ) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels.
Dual Energy Method for Breast Imaging: A Simulation Study
2015-01-01
Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNRtc) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels. PMID:26246848
Varley, Matthew C; Jaspers, Arne; Helsen, Werner F; Malone, James J
2017-09-01
Sprints and accelerations are popular performance indicators in applied sport. The methods used to define these efforts using athlete-tracking technology could affect the number of efforts reported. This study aimed to determine the influence of different techniques and settings for detecting high-intensity efforts using global positioning system (GPS) data. Velocity and acceleration data from a professional soccer match were recorded via 10-Hz GPS. Velocity data were filtered using either a median or an exponential filter. Acceleration data were derived from velocity data over a 0.2-s time interval (with and without an exponential filter applied) and a 0.3-second time interval. High-speed-running (≥4.17 m/s 2 ), sprint (≥7.00 m/s 2 ), and acceleration (≥2.78 m/s 2 ) efforts were then identified using minimum-effort durations (0.1-0.9 s) to assess differences in the total number of efforts reported. Different velocity-filtering methods resulted in small to moderate differences (effect size [ES] 0.28-1.09) in the number of high-speed-running and sprint efforts detected when minimum duration was <0.5 s and small to very large differences (ES -5.69 to 0.26) in the number of accelerations when minimum duration was <0.7 s. There was an exponential decline in the number of all efforts as minimum duration increased, regardless of filtering method, with the largest declines in acceleration efforts. Filtering techniques and minimum durations substantially affect the number of high-speed-running, sprint, and acceleration efforts detected with GPS. Changes to how high-intensity efforts are defined affect reported data. Therefore, consistency in data processing is advised.
Choi, Tayoung; Ganapathy, Sriram; Jung, Jaehak; Savage, David R.; Lakshmanan, Balasubramanian; Vecasey, Pamela M.
2013-04-16
A system and method for detecting a low performing cell in a fuel cell stack using measured cell voltages. The method includes determining that the fuel cell stack is running, the stack coolant temperature is above a certain temperature and the stack current density is within a relatively low power range. The method further includes calculating the average cell voltage, and determining whether the difference between the average cell voltage and the minimum cell voltage is greater than a predetermined threshold. If the difference between the average cell voltage and the minimum cell voltage is greater than the predetermined threshold and the minimum cell voltage is less than another predetermined threshold, then the method increments a low performing cell timer. A ratio of the low performing cell timer and a system run timer is calculated to identify a low performing cell.
Gabelmann, Jeffrey M.; Kattner, J. Stephen; Houston, Robert A.
2006-12-19
This invention is an ultra-low frequency electromagnetic telemetry receiver which fuses multiple input receive sources to synthesize a decodable message packet from a noise corrupted telemetry message string. Each block of telemetry data to be sent to the surface receiver from a borehole tool is digitally encoded into a data packet prior to transmission. The data packet is modulated onto the ULF EM carrier wave and transmitted from the borehole to the surface and then are simultaneously detected by multiple receive sensors disbursed within the rig environment. The receive sensors include, but are not limited to, electric field and magnetic field sensors. The spacing of the surface receive elements is such that noise generators are unequally coupled to each receive element due to proximity and/or noise generator type (i.e. electric or magnetic field generators). The receiver utilizes a suite of decision metrics to reconstruct the original, non noise-corrupted data packet from the observation matrix via the estimation of individual data frames. The receiver will continue this estimation process until: 1) the message validates, or 2) a preset "confidence threshold" is reached whereby frames within the observation matrix are no longer "trusted".
Note: A new method for directly reducing the sampling jitter noise of the digital phasemeter
NASA Astrophysics Data System (ADS)
Liang, Yu-Rong
2018-03-01
The sampling jitter noise is one non-negligible noise source of the digital phasemeter used for space gravitational wave detection missions. This note provides a new method for directly reducing the sampling jitter noise of the digital phasemeter, by adding a dedicated signal of which the frequency, amplitude, and initial phase should be pre-set. In contrast to the phase correction using the pilot-tone in the work of Burnett, Gerberding et al., Liang et al., Ales et al., Gerberding et al., and Ware et al. [M.Sc. thesis, Luleå University of Technology, 2010; Classical Quantum Gravity 30, 235029 (2013); Rev. Sci. Instrum. 86, 016106 (2015); Rev. Sci. Instrum. 86, 084502 (2015); Rev. Sci. Instrum. 86, 074501 (2015); and Proceedings of the Earth Science Technology Conference (NASA, USA, 2006)], the new method is intrinsically additive noise suppression. The experiment results validate that the new method directly reduces the sampling jitter noise without data post-processing and provides the same phase measurement noise level (10-6 rad/Hz1/2 at 0.1 Hz) as the pilot-tone correction.
Target Coverage in Wireless Sensor Networks with Probabilistic Sensors
Shan, Anxing; Xu, Xianghua; Cheng, Zongmao
2016-01-01
Sensing coverage is a fundamental problem in wireless sensor networks (WSNs), which has attracted considerable attention. Conventional research on this topic focuses on the 0/1 coverage model, which is only a coarse approximation to the practical sensing model. In this paper, we study the target coverage problem, where the objective is to find the least number of sensor nodes in randomly-deployed WSNs based on the probabilistic sensing model. We analyze the joint detection probability of target with multiple sensors. Based on the theoretical analysis of the detection probability, we formulate the minimum ϵ-detection coverage problem. We prove that the minimum ϵ-detection coverage problem is NP-hard and present an approximation algorithm called the Probabilistic Sensor Coverage Algorithm (PSCA) with provable approximation ratios. To evaluate our design, we analyze the performance of PSCA theoretically and also perform extensive simulations to demonstrate the effectiveness of our proposed algorithm. PMID:27618902
Programmable Positioner For Spot Welding
NASA Technical Reports Server (NTRS)
Roden, William A.
1989-01-01
Welding station mechanized by installing preset indexing system and gear drive. Mechanism includes a low-cost, versatile, single-axis motion control and motor drive to provide fully-automatic weld sequencing and spot-to-spot spacing. Welding station relieves operator of some difficult, tedious tasks and increases both productivity and quality of welds. Results in welds of higher quality and greater accuracy, fewer weld defects, and faster welding operation.
[Microcontroller temperature regulator MPT110 for drying-sterilizing cabinets].
Kostin, N N; Gavrishchuk, V I; Zelepukin, S A; Shkulepa, V M; Zharov, E N
2002-01-01
The paper describes a MPT-110 temperature microcontroller developed by the closed joint-stock company "OPLEKS" (Orel, Russia) and the results of comparative tests performed in the @IIICC-80 drying sterilizing cabinet. The use of the MPT-110 controller is shown to improve the quality of control and to shorten the times that is taken for the cabinet to reach the preset temperature point.
STS-41 crewmembers pose on OV-103's middeck for inflight (in-space) portrait
1990-10-10
STS041-26-007 (6-10 Oct 1990) --- A 35mm preset camera on Discovery's middeck captures the traditional in-space portrait of the STS-41 crewmembers. In front are (l.-r.) Astronauts Richard N. Richards, mission commander; and Robert D. Cabana, pilot. In the rear are (l.-r.) Astronauts Thomas D. Akers, Bruce E. Melnick and William M. Shepherd.
STS-30 crewmembers pose for onboard portrait on OV-104's aft flight deck
1989-05-08
STS030-21-008 (4-8 May 1989) --- A traditional in-space crew portrait for STS-30 aboard the Atlantis. Astronaut Mary L. Cleave is in front. Others pictured, left to right, are astronauts Norman E. Thagard, Ronald J. Grabe, David M. Walker and Mark C. Lee. An automatic, pre-set 35mm camera using color negative film recorded the scene.
Non-Invasive Timing of Gas Gun Projectiles with Light Detection and Ranging
NASA Astrophysics Data System (ADS)
Goodwin, Peter; Wu, Ming; Dattelbaum, Dana
2013-06-01
We have developed a Light Detection and Ranging (LIDAR) diagnostic to track the position of a projectile inside of the gas gun barrel in real-time. This capability permits the generation of precisely timed trigger pulses useful for pre-triggering high-latency diagnostics such as a flash lamp-pumped laser. An initial feasibility test was performed using a 72 mm bore single-stage gas gun routinely used for dynamic research at Los Alamos National Laboratory. A 655-nm pulsed (~100 ps) diode laser operating at a pulse repetition rate of ~100 kHz was used to interrogate the position of the moving projectile in real-time. The position of the projectile in the gun barrel was tracked over a distance of ~3 meters prior to impact. The position record showed that the projectile moved at a constant velocity (483 m/s) prior to impacting the target. This velocity was in good agreement with independent measurements of the projectile velocity by photon Doppler velocimetry, and timing of the passage of the projectile through optical marker beams positioned at the muzzle of the gun. The LIDAR return can be processed in real-time to generate pre-trigger pulses at preset separations between the projectile and target. Work funded by LANL Laboratory Directed Research Project 2011012DR. LA-UR-13-21121, approved for public release.
Minimum viewing angle for visually guided ground speed control in bumblebees.
Baird, Emily; Kornfeldt, Torill; Dacke, Marie
2010-05-01
To control flight, flying insects extract information from the pattern of visual motion generated during flight, known as optic flow. To regulate their ground speed, insects such as honeybees and Drosophila hold the rate of optic flow in the axial direction (front-to-back) constant. A consequence of this strategy is that its performance varies with the minimum viewing angle (the deviation from the frontal direction of the longitudinal axis of the insect) at which changes in axial optic flow are detected. The greater this angle, the later changes in the rate of optic flow, caused by changes in the density of the environment, will be detected. The aim of the present study is to examine the mechanisms of ground speed control in bumblebees and to identify the extent of the visual range over which optic flow for ground speed control is measured. Bumblebees were trained to fly through an experimental tunnel consisting of parallel vertical walls. Flights were recorded when (1) the distance between the tunnel walls was either 15 or 30 cm, (2) the visual texture on the tunnel walls provided either strong or weak optic flow cues and (3) the distance between the walls changed abruptly halfway along the tunnel's length. The results reveal that bumblebees regulate ground speed using optic flow cues and that changes in the rate of optic flow are detected at a minimum viewing angle of 23-30 deg., with a visual field that extends to approximately 155 deg. By measuring optic flow over a visual field that has a low minimum viewing angle, bumblebees are able to detect and respond to changes in the proximity of the environment well before they are encountered.
Statistical detection of patterns in unidimensional distributions by continuous wavelet transforms
NASA Astrophysics Data System (ADS)
Baluev, R. V.
2018-04-01
Objective detection of specific patterns in statistical distributions, like groupings or gaps or abrupt transitions between different subsets, is a task with a rich range of applications in astronomy: Milky Way stellar population analysis, investigations of the exoplanets diversity, Solar System minor bodies statistics, extragalactic studies, etc. We adapt the powerful technique of the wavelet transforms to this generalized task, making a strong emphasis on the assessment of the patterns detection significance. Among other things, our method also involves optimal minimum-noise wavelets and minimum-noise reconstruction of the distribution density function. Based on this development, we construct a self-closed algorithmic pipeline aimed to process statistical samples. It is currently applicable to single-dimensional distributions only, but it is flexible enough to undergo further generalizations and development.
Van Beek, T A; Blaakmeer, A
1989-03-03
A method has been developed for the quantitation of the bitter component limonin in grapefruit juice and other citrus juices. The sample clean-up consisted of centrifugation, filtration and a selective, rapid and reproducible purification with a C2 solid-phase extraction column. The limonin concentration was determined by high-performance liquid chromatography on a C18 column with UV detection at 210 nm. A linear response was obtained from 0.0 to 45 ppm limonin. The minimum detectable amount was 2 ng. The minimum concentration which was detected without concentration with good precision was 0.1 ppm. The method was also used for the determination of limonin in different types of oranges, including navel oranges, mandarins, lemons, limes, pomelos and uglis.
NASA Astrophysics Data System (ADS)
Fathy, Ibrahim
2016-07-01
This paper presents a statistical study of different types of large-scale geomagnetic pulsation (Pc3, Pc4, Pc5 and Pi2) detected simultaneously by two MAGDAS stations located at Fayum (Geo. Coordinates 29.18 N and 30.50 E) and Aswan (Geo. Coordinates 23.59 N and 32.51 E) in Egypt. The second order butter-worth band-pass filter has been used to filter and analyze the horizontal H-component of the geomagnetic field in one-second data. The data was collected during the solar minimum of the current solar cycle 24. We list the most energetic pulsations detected by the two stations instantaneously, in addition; the average amplitude of the pulsation signals was calculated.
Simulating future uncertainty to guide the selection of survey designs for long-term monitoring
Garman, Steven L.; Schweiger, E. William; Manier, Daniel J.; Gitzen, Robert A.; Millspaugh, Joshua J.; Cooper, Andrew B.; Licht, Daniel S.
2012-01-01
A goal of environmental monitoring is to provide sound information on the status and trends of natural resources (Messer et al. 1991, Theobald et al. 2007, Fancy et al. 2009). When monitoring observations are acquired by measuring a subset of the population of interest, probability sampling as part of a well-constructed survey design provides the most reliable and legally defensible approach to achieve this goal (Cochran 1977, Olsen et al. 1999, Schreuder et al. 2004; see Chapters 2, 5, 6, 7). Previous works have described the fundamentals of sample surveys (e.g. Hansen et al. 1953, Kish 1965). Interest in survey designs and monitoring over the past 15 years has led to extensive evaluations and new developments of sample selection methods (Stevens and Olsen 2004), of strategies for allocating sample units in space and time (Urquhart et al. 1993, Overton and Stehman 1996, Urquhart and Kincaid 1999), and of estimation (Lesser and Overton 1994, Overton and Stehman 1995) and variance properties (Larsen et al. 1995, Stevens and Olsen 2003) of survey designs. Carefully planned, “scientific” (Chapter 5) survey designs have become a standard in contemporary monitoring of natural resources. Based on our experience with the long-term monitoring program of the US National Park Service (NPS; Fancy et al. 2009; Chapters 16, 22), operational survey designs tend to be selected using the following procedures. For a monitoring indicator (i.e. variable or response), a minimum detectable trend requirement is specified, based on the minimum level of change that would result in meaningful change (e.g. degradation). A probability of detecting this trend (statistical power) and an acceptable level of uncertainty (Type I error; see Chapter 2) within a specified time frame (e.g. 10 years) are specified to ensure timely detection. Explicit statements of the minimum detectable trend, the time frame for detecting the minimum trend, power, and acceptable probability of Type I error (α) collectively form the quantitative sampling objective.
NASA Technical Reports Server (NTRS)
Generazio, Edward R.
2011-01-01
The capability of an inspection system is established by applications of various methodologies to determine the probability of detection (POD). One accepted metric of an adequate inspection system is that for a minimum flaw size and all greater flaw sizes, there is 0.90 probability of detection with 95% confidence (90/95 POD). Directed design of experiments for probability of detection (DOEPOD) has been developed to provide an efficient and accurate methodology that yields estimates of POD and confidence bounds for both Hit-Miss or signal amplitude testing, where signal amplitudes are reduced to Hit-Miss by using a signal threshold Directed DOEPOD uses a nonparametric approach for the analysis or inspection data that does require any assumptions about the particular functional form of a POD function. The DOEPOD procedure identifies, for a given sample set whether or not the minimum requirement of 0.90 probability of detection with 95% confidence is demonstrated for a minimum flaw size and for all greater flaw sizes (90/95 POD). The DOEPOD procedures are sequentially executed in order to minimize the number of samples needed to demonstrate that there is a 90/95 POD lower confidence bound at a given flaw size and that the POD is monotonic for flaw sizes exceeding that 90/95 POD flaw size. The conservativeness of the DOEPOD methodology results is discussed. Validated guidelines for binomial estimation of POD for fracture critical inspection are established.
Research on Abnormal Detection Based on Improved Combination of K - means and SVDD
NASA Astrophysics Data System (ADS)
Hao, Xiaohong; Zhang, Xiaofeng
2018-01-01
In order to improve the efficiency of network intrusion detection and reduce the false alarm rate, this paper proposes an anomaly detection algorithm based on improved K-means and SVDD. The algorithm first uses the improved K-means algorithm to cluster the training samples of each class, so that each class is independent and compact in class; Then, according to the training samples, the SVDD algorithm is used to construct the minimum superspheres. The subordinate relationship of the samples is determined by calculating the distance of the minimum superspheres constructed by SVDD. If the test sample is less than the center of the hypersphere, the test sample belongs to this class, otherwise it does not belong to this class, after several comparisons, the final test of the effective detection of the test sample.In this paper, we use KDD CUP99 data set to simulate the proposed anomaly detection algorithm. The results show that the algorithm has high detection rate and low false alarm rate, which is an effective network security protection method.
Minimum depth of investigation for grounded-wire TEM due to self-transients
NASA Astrophysics Data System (ADS)
Zhou, Nannan; Xue, Guoqiang
2018-05-01
The grounded-wire transient electromagnetic method (TEM) has been widely used for near-surface metalliferous prospecting, oil and gas exploration, and hydrogeological surveying in the subsurface. However, it is commonly observed that such TEM signal is contaminated by the self-transient process occurred at the early stage of data acquisition. Correspondingly, there exists a minimum depth of investigation, above which the observed signal is not applicable for reliable data processing and interpretation. Therefore, for achieving a more comprehensive understanding of the TEM method, it is necessary to perform research on the self-transient process and moreover develop an approach for quantifying the minimum detection depth. In this paper, we first analyze the temporal procedure of the equivalent circuit of the TEM method and present a theoretical equation for estimating the self-induction voltage based on the inductor of the transmitting wire. Then, numerical modeling is applied for building the relationship between the minimum depth of investigation and various properties, including resistivity of the earth, offset, and source length. It is guide for the design of survey parameters when the grounded-wire TEM is applied to the shallow detection. Finally, it is verified through applications to a coal field in China.
Development and evaluation of a technique for in vivo monitoring of 60Co in human lungs
NASA Astrophysics Data System (ADS)
de Mello, J. Q.; Lucena, E. A.; Dantas, A. L. A.; Dantas, B. M.
2016-07-01
60Co is a fission product of 235U and represents a risk of internal exposure of workers in nuclear power plants, especially those involved in the maintenance of potentially contaminated parts and equipment. The control of 60Co intake by inhalation can be performed through in vivo monitoring. This work describes the evaluation of a technique through the minimum detectable activity and the corresponding minimum detectable effective doses, based on biokinetic and dosimetric models of 60Co in the human body. The results allow to state that the technique is suitable either for monitoring of occupational exposures or evaluation of accidental intake.
THREE PLANETS ORBITING WOLF 1061
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, D. J.; Wittenmyer, R. A.; Tinney, C. G.
We use archival HARPS spectra to detect three planets orbiting the M3 dwarf Wolf 1061 (GJ 628). We detect a 1.36 M{sub ⊕} minimum-mass planet with an orbital period P = 4.888 days (Wolf 1061b), a 4.25 M{sub ⊕} minimum-mass planet with orbital period P = 17.867 days (Wolf 1061c), and a likely 5.21 M{sub ⊕} minimum-mass planet with orbital period P = 67.274 days (Wolf 1061d). All of the planets are of sufficiently low mass that they may be rocky in nature. The 17.867 day planet falls within the habitable zone for Wolf 1061 and the 67.274 day planetmore » falls just outside the outer boundary of the habitable zone. There are no signs of activity observed in the bisector spans, cross-correlation FWHMs, calcium H and K indices, NaD indices, or Hα indices near the planetary periods. We use custom methods to generate a cross-correlation template tailored to the star. The resulting velocities do not suffer the strong annual variation observed in the HARPS DRS velocities. This differential technique should deliver better exploitation of the archival HARPS data for the detection of planets at extremely low amplitudes.« less
Su, Zhong; Zhang, Lisha; Ramakrishnan, V; Hagan, Michael; Anscher, Mitchell
2011-05-01
To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading accuracy in the presence of wireless electromagnetic transponders inside a phantom. A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with/without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with/without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit. Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0.5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%. The phantom study indicated that the Calypso System's localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems.
NASA Astrophysics Data System (ADS)
Chanyshev, AI; Belousova, OE
2018-03-01
The authors determine stress and deformation in a heterogeneous rock mass at the preset displacement and Cauchy stress vector at the boundary of an underground excavation. The influence of coordinates on Young’s modulus, shear modulus and ultimate strength is shown. It is found that regions of tension and compression alternate at the excavation boundary—i.e. zonal rock disintegration phenomenon is observed.
Droning On: American Strategic Myopia Toward Unmanned Aerial Systems
2013-12-01
torpedo, nicknamed the “Bug.”3 This system consisted of pre-set pneumatic and electrical controls that stabilized and guided it toward...race their homemade drones around Mount Damavand.88 These competitions and DIY efforts provide short-term innovation of unmanned technologies. This...an even greater threat to the homeland comes from homegrown or lone wolf actor’s possession of unmanned technology. DIY kits aid in building drones
Asmanes, Charles
1979-01-01
A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.
Free sixteen harmonic Fourier series web app with sound
NASA Astrophysics Data System (ADS)
Ruiz, Michael J.
2018-03-01
An online HTML5 Fourier synthesizer app is provided that allows students to manipulate sixteen harmonics and construct periodic waves. Students can set the amplitudes and phases for each harmonic, seeing the resulting waveforms and hearing the sounds. Five waveform presets are included: sine, triangle, square, ramp (sawtooth), and pulse train. The program is free for non-commercial use and can also be downloaded for running offline.
Portable Device Slices Thermoplastic Prepregs
NASA Technical Reports Server (NTRS)
Taylor, Beverly A.; Boston, Morton W.; Wilson, Maywood L.
1993-01-01
Prepreg slitter designed to slit various widths rapidly by use of slicing bar holding several blades, each capable of slicing strip of preset width in single pass. Produces material evenly sliced and does not contain jagged edges. Used for various applications in such batch processes involving composite materials as press molding and autoclaving, and in such continuous processes as pultrusion. Useful to all manufacturers of thermoplastic composites, and in slicing B-staged thermoset composites.
A noise power spectrum study of a new model-based iterative reconstruction system: Veo 3.0.
Li, Guang; Liu, Xinming; Dodge, Cristina T; Jensen, Corey T; Rong, X John
2016-09-08
The purpose of this study was to evaluate performance of the third generation of model-based iterative reconstruction (MBIR) system, Veo 3.0, based on noise power spectrum (NPS) analysis with various clinical presets over a wide range of clinically applicable dose levels. A CatPhan 600 surrounded by an oval, fat-equivalent ring to mimic patient size/shape was scanned 10 times at each of six dose levels on a GE HD 750 scanner. NPS analysis was performed on images reconstructed with various Veo 3.0 preset combinations for comparisons of those images reconstructed using Veo 2.0, filtered back projection (FBP) and adaptive statistical iterative reconstruc-tion (ASiR). The new Target Thickness setting resulted in higher noise in thicker axial images. The new Texture Enhancement function achieved a more isotropic noise behavior with less image artifacts. Veo 3.0 provides additional reconstruction options designed to allow the user choice of balance between spatial resolution and image noise, relative to Veo 2.0. Veo 3.0 provides more user selectable options and in general improved isotropic noise behavior in comparison to Veo 2.0. The overall noise reduction performance of both versions of MBIR was improved in comparison to FBP and ASiR, especially at low-dose levels. © 2016 The Authors.
Sample allocation balancing overall representativeness and stratum precision.
Diaz-Quijano, Fredi Alexander
2018-05-07
In large-scale surveys, it is often necessary to distribute a preset sample size among a number of strata. Researchers must make a decision between prioritizing overall representativeness or precision of stratum estimates. Hence, I evaluated different sample allocation strategies based on stratum size. The strategies evaluated herein included allocation proportional to stratum population; equal sample for all strata; and proportional to the natural logarithm, cubic root, and square root of the stratum population. This study considered the fact that, from a preset sample size, the dispersion index of stratum sampling fractions is correlated with the population estimator error and the dispersion index of stratum-specific sampling errors would measure the inequality in precision distribution. Identification of a balanced and efficient strategy was based on comparing those both dispersion indices. Balance and efficiency of the strategies changed depending on overall sample size. As the sample to be distributed increased, the most efficient allocation strategies were equal sample for each stratum; proportional to the logarithm, to the cubic root, to square root; and that proportional to the stratum population, respectively. Depending on sample size, each of the strategies evaluated could be considered in optimizing the sample to keep both overall representativeness and stratum-specific precision. Copyright © 2018 Elsevier Inc. All rights reserved.
Tracer-Test Planning Using the Efficient Hydrologic Tracer ...
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be
EFFICIENT HYDROLOGICAL TRACER-TEST DESIGN (EHTD ...
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to
An in vitro lung model to assess true shunt fraction by multiple inert gas elimination.
Varadarajan, Balamurugan; Vogt, Andreas; Hartwich, Volker; Vasireddy, Rakesh; Consiglio, Jolanda; Hugi-Mayr, Beate; Eberle, Balthasar
2017-01-01
The Multiple Inert Gas Elimination Technique, based on Micropore Membrane Inlet Mass Spectrometry, (MMIMS-MIGET) has been designed as a rapid and direct method to assess the full range of ventilation-to-perfusion (V/Q) ratios. MMIMS-MIGET distributions have not been assessed in an experimental setup with predefined V/Q-distributions. We aimed (I) to construct a novel in vitro lung model (IVLM) for the simulation of predefined V/Q distributions with five gas exchange compartments and (II) to correlate shunt fractions derived from MMIMS-MIGET with preset reference shunt values of the IVLM. Five hollow-fiber membrane oxygenators switched in parallel within a closed extracorporeal oxygenation circuit were ventilated with sweep gas (V) and perfused with human red cell suspension or saline (Q). Inert gas solution was infused into the perfusion circuit of the gas exchange assembly. Sweep gas flow (V) was kept constant and reference shunt fractions (IVLM-S) were established by bypassing one or more oxygenators with perfusate flow (Q). The derived shunt fractions (MM-S) were determined using MIGET by MMIMS from the retention data. Shunt derived by MMIMS-MIGET correlated well with preset reference shunt fractions. The in vitro lung model is a convenient system for the setup of predefined true shunt fractions in validation of MMIMS-MIGET.
Wang, Jianji; Zheng, Nanning
2013-09-01
Fractal image compression (FIC) is an image coding technology based on the local similarity of image structure. It is widely used in many fields such as image retrieval, image denoising, image authentication, and encryption. FIC, however, suffers from the high computational complexity in encoding. Although many schemes are published to speed up encoding, they do not easily satisfy the encoding time or the reconstructed image quality requirements. In this paper, a new FIC scheme is proposed based on the fact that the affine similarity between two blocks in FIC is equivalent to the absolute value of Pearson's correlation coefficient (APCC) between them. First, all blocks in the range and domain pools are chosen and classified using an APCC-based block classification method to increase the matching probability. Second, by sorting the domain blocks with respect to APCCs between these domain blocks and a preset block in each class, the matching domain block for a range block can be searched in the selected domain set in which these APCCs are closer to APCC between the range block and the preset block. Experimental results show that the proposed scheme can significantly speed up the encoding process in FIC while preserving the reconstructed image quality well.
A database de-identification framework to enable direct queries on medical data for secondary use.
Erdal, B S; Liu, J; Ding, J; Chen, J; Marsh, C B; Kamal, J; Clymer, B D
2012-01-01
To qualify the use of patient clinical records as non-human-subject for research purpose, electronic medical record data must be de-identified so there is minimum risk to protected health information exposure. This study demonstrated a robust framework for structured data de-identification that can be applied to any relational data source that needs to be de-identified. Using a real world clinical data warehouse, a pilot implementation of limited subject areas were used to demonstrate and evaluate this new de-identification process. Query results and performances are compared between source and target system to validate data accuracy and usability. The combination of hashing, pseudonyms, and session dependent randomizer provides a rigorous de-identification framework to guard against 1) source identifier exposure; 2) internal data analyst manually linking to source identifiers; and 3) identifier cross-link among different researchers or multiple query sessions by the same researcher. In addition, a query rejection option is provided to refuse queries resulting in less than preset numbers of subjects and total records to prevent users from accidental subject identification due to low volume of data. This framework does not prevent subject re-identification based on prior knowledge and sequence of events. Also, it does not deal with medical free text de-identification, although text de-identification using natural language processing can be included due its modular design. We demonstrated a framework resulting in HIPAA Compliant databases that can be directly queried by researchers. This technique can be augmented to facilitate inter-institutional research data sharing through existing middleware such as caGrid.
NASA Astrophysics Data System (ADS)
Cheng, Yao; Zhou, Ning; Zhang, Weihua; Wang, Zhiwei
2018-07-01
Minimum entropy deconvolution is a widely-used tool in machinery fault diagnosis, because it enhances the impulse component of the signal. The filter coefficients that greatly influence the performance of the minimum entropy deconvolution are calculated by an iterative procedure. This paper proposes an improved deconvolution method for the fault detection of rolling element bearings. The proposed method solves the filter coefficients by the standard particle swarm optimization algorithm, assisted by a generalized spherical coordinate transformation. When optimizing the filters performance for enhancing the impulses in fault diagnosis (namely, faulty rolling element bearings), the proposed method outperformed the classical minimum entropy deconvolution method. The proposed method was validated in simulation and experimental signals from railway bearings. In both simulation and experimental studies, the proposed method delivered better deconvolution performance than the classical minimum entropy deconvolution method, especially in the case of low signal-to-noise ratio.
Applying six classifiers to airborne hyperspectral imagery for detecting giant reed
USDA-ARS?s Scientific Manuscript database
This study evaluated and compared six different image classifiers, including minimum distance (MD), Mahalanobis distance (MAHD), maximum likelihood (ML), spectral angle mapper (SAM), mixture tuned matched filtering (MTMF) and support vector machine (SVM), for detecting and mapping giant reed (Arundo...
In situ single cell detection via microfluidic magnetic bead assay
KC, Pawan; Zhang, Ge; Zhe, Jiang
2017-01-01
We present a single cell detection device based on magnetic bead assay and micro Coulter counters. This device consists of two successive micro Coulter counters, coupled with a high gradient magnetic field generated by an external magnet. The device can identify single cells in terms of the transit time difference of the cell through the two micro Coulter counters. Target cells are conjugated with magnetic beads via specific antibody and antigen binding. A target cell traveling through the two Coulter counters interacts with the magnetic field, and have a longer transit time at the 1st counter than that at the 2nd counter. In comparison, a non-target cell has no interaction with the magnetic field, and hence has nearly the same transit times through the two counters. Each cell passing through the two counters generates two consecutive voltage pulses one after the other; the pulse widths and magnitudes indicating the cell’s transit times through the counters and the cell’s size respectively. Thus, by measuring the pulse widths (transit times) of each cell through the two counters, each single target cell can be differentiated from non-target cells even if they have similar sizes. We experimentally proved that the target human umbilical vein endothelial cells (HUVECs) and non-target rat adipose-derived stem cells (rASCs) have significant different transit time distribution, from which we can determine the recognition regions for both cell groups quantitatively. We further demonstrated that within a mixed cell population of rASCs and HUVECs, HUVECs can be detected in situ and the measured HUVECs ratios agree well with the pre-set ratios. With the simple device structure and easy sample preparation, this method is expected to enable single cell detection in a continuous flow and can be applied to facilitate general cell detection applications such as stem cell identification and enumeration. PMID:28222140
In situ single cell detection via microfluidic magnetic bead assay.
Liu, Fan; Kc, Pawan; Zhang, Ge; Zhe, Jiang
2017-01-01
We present a single cell detection device based on magnetic bead assay and micro Coulter counters. This device consists of two successive micro Coulter counters, coupled with a high gradient magnetic field generated by an external magnet. The device can identify single cells in terms of the transit time difference of the cell through the two micro Coulter counters. Target cells are conjugated with magnetic beads via specific antibody and antigen binding. A target cell traveling through the two Coulter counters interacts with the magnetic field, and have a longer transit time at the 1st counter than that at the 2nd counter. In comparison, a non-target cell has no interaction with the magnetic field, and hence has nearly the same transit times through the two counters. Each cell passing through the two counters generates two consecutive voltage pulses one after the other; the pulse widths and magnitudes indicating the cell's transit times through the counters and the cell's size respectively. Thus, by measuring the pulse widths (transit times) of each cell through the two counters, each single target cell can be differentiated from non-target cells even if they have similar sizes. We experimentally proved that the target human umbilical vein endothelial cells (HUVECs) and non-target rat adipose-derived stem cells (rASCs) have significant different transit time distribution, from which we can determine the recognition regions for both cell groups quantitatively. We further demonstrated that within a mixed cell population of rASCs and HUVECs, HUVECs can be detected in situ and the measured HUVECs ratios agree well with the pre-set ratios. With the simple device structure and easy sample preparation, this method is expected to enable single cell detection in a continuous flow and can be applied to facilitate general cell detection applications such as stem cell identification and enumeration.
Inhomogeneous models of the Venus clouds containing sulfur
NASA Technical Reports Server (NTRS)
Smith, S. M.; Pollack, J. B.; Giver, L. P.; Cuzzi, J. N.; Podolak, M.
1979-01-01
Based on the suggestion that elemental sulfur is responsible for the yellow color of Venus, calculations are compared at 3.4 microns of the reflectivity phase function of two sulfur containing inhomogeneous cloud models with that of a homogeneous model. Assuming reflectivity observations with 25% or less total error, comparison of the model calculations leads to a minimum detectable mass of sulfur equal to 7% of the mass of sulfuric acid for the inhomogeneous drop model. For the inhomogeneous cloud model the comparison leads to a minimum detectable mass of sulfur between 17% and 38% of the mass of the acid drops, depending upon the actual size of the large particles. It is concluded that moderately accurate 3.4 microns reflectivity observations are capable of detecting quite small amounts of elemental sulfur at the top of the Venus clouds.
Code of Federal Regulations, 2010 CFR
2010-07-01
... minimum pressure drop and liquid flow-rate at or above the operating levels established during the... leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month... control Maintain the minimum sorbent or carbon injection rate at or above the operating levels established...
Code of Federal Regulations, 2011 CFR
2011-07-01
... minimum pressure drop and liquid flow-rate at or above the operating levels established during the... leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month... control Maintain the minimum sorbent or carbon injection rate at or above the operating levels established...
A Fuel-Efficient Conflict Resolution Maneuver for Separation Assurance
NASA Technical Reports Server (NTRS)
Bowe, Aisha Ruth; Santiago, Confesor
2012-01-01
Automated separation assurance algorithms are envisioned to play an integral role in accommodating the forecasted increase in demand of the National Airspace System. Developing a robust, reliable, air traffic management system involves safely increasing efficiency and throughput while considering the potential impact on users. This experiment seeks to evaluate the benefit of augmenting a conflict detection and resolution algorithm to consider a fuel efficient, Zero-Delay Direct-To maneuver, when resolving a given conflict based on either minimum fuel burn or minimum delay. A total of twelve conditions were tested in a fast-time simulation conducted in three airspace regions with mixed aircraft types and light weather. Results show that inclusion of this maneuver has no appreciable effect on the ability of the algorithm to safely detect and resolve conflicts. The results further suggest that enabling the Zero-Delay Direct-To maneuver significantly increases the cumulative fuel burn savings when choosing resolution based on minimum fuel burn while marginally increasing the average delay per resolution.
A novel adaptive, real-time algorithm to detect gait events from wearable sensors.
Chia Bejarano, Noelia; Ambrosini, Emilia; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Monticone, Marco; Ferrante, Simona
2015-05-01
A real-time, adaptive algorithm based on two inertial and magnetic sensors placed on the shanks was developed for gait-event detection. For each leg, the algorithm detected the Initial Contact (IC), as the minimum of the flexion/extension angle, and the End Contact (EC) and the Mid-Swing (MS), as minimum and maximum of the angular velocity, respectively. The algorithm consisted of calibration, real-time detection, and step-by-step update. Data collected from 22 healthy subjects (21 to 85 years) walking at three self-selected speeds were used to validate the algorithm against the GaitRite system. Comparable levels of accuracy and significantly lower detection delays were achieved with respect to other published methods. The algorithm robustness was tested on ten healthy subjects performing sudden speed changes and on ten stroke subjects (43 to 89 years). For healthy subjects, F1-scores of 1 and mean detection delays lower than 14 ms were obtained. For stroke subjects, F1-scores of 0.998 and 0.944 were obtained for IC and EC, respectively, with mean detection delays always below 31 ms. The algorithm accurately detected gait events in real time from a heterogeneous dataset of gait patterns and paves the way for the design of closed-loop controllers for customized gait trainings and/or assistive devices.
Development of a homogeneous pulse shape discriminating flow-cell radiation detection system
NASA Astrophysics Data System (ADS)
Hastie, K. H.; DeVol, T. A.; Fjeld, R. A.
1999-02-01
A homogeneous flow-cell radiation detection system which utilizes coincidence counting and pulse shape discrimination circuitry was assembled and tested with five commercially available liquid scintillation cocktails. Two of the cocktails, Ultima Flo (Packard) and Mono Flow 5 (National Diagnostics) have low viscosities and are intended for flow applications; and three of the cocktails, Optiphase HiSafe 3 (Wallac), Ultima Gold AB (Packard), and Ready Safe (Beckman), have higher viscosities and are intended for static applications. The low viscosity cocktails were modified with 1-methylnaphthalene to increase their capability for alpha/beta pulse shape discrimination. The sample loading and pulse shape discriminator setting were optimized to give the lowest minimum detectable concentration for alpha radiation in a 30 s count time. Of the higher viscosity cocktails, Optiphase HiSafe 3 had the lowest minimum detectable activities for alpha and beta radiation, 0.2 and 0.4 Bq/ml for 233U and 90Sr/ 90Y, respectively, for a 30 s count time. The sample loading was 70% and the corresponding alpha/beta spillover was 5.5%. Of the low viscosity cocktails, Mono Flow 5 modified with 2.5% (by volume) 1-methylnaphthalene resulted in the lowest minimum detectable activities for alpha and beta radiation; 0.3 and 0.5 Bq/ml for 233U and 90Sr/ 90Y, respectively, for a 30 s count time. The sample loading was 50%, and the corresponding alpha/beta spillover was 16.6%. HiSafe 3 at a 10% sample loading was used to evaluate the system under simulated flow conditions.
The objectives of this presentation are to: review history of distribution system chlorination regulations, raise awareness on the meaning of detectable residual as it relates to chloramines, and perhaps renew dialogue on the discussion of minimum disinfectant residuals.
Determination of total sulfur content via sulfur-specific chemiluminescence detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubala, S.W.; Campbell, D.N.; DiSanzo, F.P.
A specially designed system, based upon sulfur-specific chemiluminescence detection (SSCD), was developed to permit the determination of total sulfur content in a variety of samples. This type of detection system possesses several advantages such as excellent linearity and selectivity, low minimum detectable levels, and an equimolar response to various sulfur compounds. This paper will focus on the design and application of a sulfur-specific chemiluminescence detection system for use in determining total sulfur content in gasoline.
Invariance of the bit error rate in the ancilla-assisted homodyne detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshida, Yuhsuke; Takeoka, Masahiro; Sasaki, Masahide
2010-11-15
We investigate the minimum achievable bit error rate of the discrimination of binary coherent states with the help of arbitrary ancillary states. We adopt homodyne measurement with a common phase of the local oscillator and classical feedforward control. After one ancillary state is measured, its outcome is referred to the preparation of the next ancillary state and the tuning of the next mixing with the signal. It is shown that the minimum bit error rate of the system is invariant under the following operations: feedforward control, deformations, and introduction of any ancillary state. We also discuss the possible generalization ofmore » the homodyne detection scheme.« less
Auger electron and characteristic energy loss spectra for electro-deposited americium-241
NASA Astrophysics Data System (ADS)
Varma, Matesh N.; Baum, John W.
1983-07-01
Auger electron energy spectra for electro-deposited americium-241 on platinum substrate were obtained using a cylindrical mirror analyzer. Characteristic energy loss spectra for this sample were also obtained at primary electron beam energies of 990 and 390 eV. From these measurements PI, PII, and PIII energy levels for americium-241 are determined. Auger electron energies are compared with theoretically calculated values. Minimum detectability under the present condition of sample preparation and equipment was estimated at approximately 1.2×10-8 g/cm2 or 3.9×10-8 Ci/cm2. Minimum detectability for plutonium-239 under similar conditions was estimated at about 7.2×10-10 Ci/cm2.
ERIC Educational Resources Information Center
Dong, Nianbo; Spybrook, Jessaca; Kelcey, Ben
2016-01-01
The purpose of this study is to propose a general framework for power analyses to detect the moderator effects in two- and three-level cluster randomized trials (CRTs). The study specifically aims to: (1) develop the statistical formulations for calculating statistical power, minimum detectable effect size (MDES) and its confidence interval to…
The performance of matched-field track-before-detect methods using shallow-water Pacific data.
Tantum, Stacy L; Nolte, Loren W; Krolik, Jeffrey L; Harmanci, Kerem
2002-07-01
Matched-field track-before-detect processing, which extends the concept of matched-field processing to include modeling of the source dynamics, has recently emerged as a promising approach for maintaining the track of a moving source. In this paper, optimal Bayesian and minimum variance beamforming track-before-detect algorithms which incorporate a priori knowledge of the source dynamics in addition to the underlying uncertainties in the ocean environment are presented. A Markov model is utilized for the source motion as a means of capturing the stochastic nature of the source dynamics without assuming uniform motion. In addition, the relationship between optimal Bayesian track-before-detect processing and minimum variance track-before-detect beamforming is examined, revealing how an optimal tracking philosophy may be used to guide the modification of existing beamforming techniques to incorporate track-before-detect capabilities. Further, the benefits of implementing an optimal approach over conventional methods are illustrated through application of these methods to shallow-water Pacific data collected as part of the SWellEX-1 experiment. The results show that incorporating Markovian dynamics for the source motion provides marked improvement in the ability to maintain target track without the use of a uniform velocity hypothesis.
2014-04-01
synchronization primitives based on preset templates can result in over synchronization if unchecked, possibly creating deadlock situations. Further...inputs rather than enforcing synchronization with a global clock. MRICDF models software as a network of communicating actors. Four primitive actors...control wants to send interrupt or not. Since this is shared buffer, a semaphore mechanism is assumed to synchronize the read/write of this buffer. The
Evaluation of Cathode Heater Assembly for 42 GHz, 200 kW Gyrotron
NASA Astrophysics Data System (ADS)
Sharma, S. K.; Singh, Narendra Kumar; Singh, Udaybir; Khatun, Hasina; Kumar, Nitin; Alaria, M. K.; Raju, R. S.; Jain, P. K.; Sinha, A. K.
2014-09-01
In this paper, the evaluation of cathode-heater assembly of magnetron injection gun (MIG) for 42 GHz, 200 kW gyrotron is presented. The cathode-heater assembly is purchased from M/S SEMICON.The cathode-heater assembly is experimentally studied in three different conditions; in a belljar system, during vacuum processing of MIG and during MIG testing to ensure the required rise of cathode surface temperature for pre-set heater power.
Comparison of Specifications for Head-Up Displays in the Navy A-4M, A- 7E, AV-8A, and F-14A Aircraft
1979-11-05
nomenclature and function for the A-7E aircraft (0). Modes of Opersti&n "rhe A-7i hsa ton mod a of opetition . The display formats for each mods are...tselactad TACAI radial. STP- Povildes course to selclWl preset dasti- ation point. AWL/? CO - Provides gilideo•e Information duriLng landing or preclslon
El Salvador: The Prospects for a Successful Revolution
1986-12-01
sources including an uneven impact of technology, modernization, or growth of a new religion or ideology. 12 5,m € .’ 2I...salvadoreho en el presente siglo (San Salvador, El Salvador: Impreso en El Salvador, Centroamerica, 1984). Things did not improve from 1944-61, as there were...World. Boston: Beacon Press, 1966. Moran, Mariano Castro. Funci6n polftica del ej~cito salvadoreio en el presete siglo . San Salvador, El Salvador
Distributed Beam Former for Distributed-Aperture Electronically Steered Antennas
2006-11-01
of planar or conformal aperture, it will be replaced by a distributed aperture configuration with a base-band digital network that is used to combine...beam forming network that can be designed with pre-set scanning directions. The beam former for this stage can be realized using a printed Butler...matrix (Bona et al, 2002; Neron and Delisle, 2005), a printed Rotman lens (Kilic and Dahlstrom, 2005) or other switched time delay system. The
Controlled Quantum Operations of a Semiconductor Three-Qubit System
NASA Astrophysics Data System (ADS)
Li, Hai-Ou; Cao, Gang; Yu, Guo-Dong; Xiao, Ming; Guo, Guang-Can; Jiang, Hong-Wen; Guo, Guo-Ping
2018-02-01
In a specially designed semiconductor device consisting of three capacitively coupled double quantum dots, we achieve strong and tunable coupling between a target qubit and two control qubits. We demonstrate how to completely switch on and off the target qubit's coherent rotations by presetting two control qubits' states. A Toffoli gate is, therefore, possible based on these control effects. This research paves a way for realizing full quantum-logic operations in semiconductor multiqubit systems.
NASA Astrophysics Data System (ADS)
Protsenko, A. E.; Telesh, V. V.
2015-11-01
The possibility of increasing the static flexural strength of polymer composite materials and reducing their anisotropy by vacuum autoclave curing, during which gelation across the whole thickness of prepregs is carried out in a narrow time range, is shown. This is achieved by introducing a preset concentration of catalysts into the less heated layers or inhibitors in the more heated ones of the prepreg.
ERIC Educational Resources Information Center
Legge, Dina Boccuzzi; DeBar, Ruth M.; Alber-Morgan, Sheila R.
2010-01-01
This study examined the effects of self-monitoring on the on-task behavior of three fifth and sixth grade boys with autism and other disabilities. While completing math assignments independently, the students wore an electronic device called a MotivAider[R] that vibrated at pre-set time schedules prompting the students to self-record whether or…
Xue, Xiaonan; Shore, Roy E; Ye, Xiangyang; Kim, Mimi Y
2004-10-01
Occupational exposures are often recorded as zero when the exposure is below the minimum detection level (BMDL). This can lead to an underestimation of the doses received by individuals and can lead to biased estimates of risk in occupational epidemiologic studies. The extent of the exposure underestimation is increased with the magnitude of the minimum detection level (MDL) and the frequency of monitoring. This paper uses multiple imputation methods to impute values for the missing doses due to BMDL. A Gibbs sampling algorithm is developed to implement the method, which is applied to two distinct scenarios: when dose information is available for each measurement (but BMDL is recorded as zero or some other arbitrary value), or when the dose information available represents the summation of a series of measurements (e.g., only yearly cumulative exposure is available but based on, say, weekly measurements). Then the average of the multiple imputed exposure realizations for each individual is used to obtain an unbiased estimate of the relative risk associated with exposure. Simulation studies are used to evaluate the performance of the estimators. As an illustration, the method is applied to a sample of historical occupational radiation exposure data from the Oak Ridge National Laboratory.
Short version of the Depression Anxiety Stress Scale-21: is it valid for Brazilian adolescents?
da Silva, Hítalo Andrade; dos Passos, Muana Hiandra Pereira; de Oliveira, Valéria Mayaly Alves; Palmeira, Aline Cabral; Pitangui, Ana Carolina Rodarti; de Araújo, Rodrigo Cappato
2016-01-01
ABSTRACT Objective To evaluate the interday reproducibility, agreement and validity of the construct of short version of the Depression Anxiety Stress Scale-21 applied to adolescents. Methods The sample consisted of adolescents of both sexes, aged between 10 and 19 years, who were recruited from schools and sports centers. The validity of the construct was performed by exploratory factor analysis, and reliability was calculated for each construct using the intraclass correlation coefficient, standard error of measurement and the minimum detectable change. Results The factor analysis combining the items corresponding to anxiety and stress in a single factor, and depression in a second factor, showed a better match of all 21 items, with higher factor loadings in their respective constructs. The reproducibility values for depression were intraclass correlation coefficient with 0.86, standard error of measurement with 0.80, and minimum detectable change with 2.22; and, for anxiety/stress: intraclass correlation coefficient with 0.82, standard error of measurement with 1.80, and minimum detectable change with 4.99. Conclusion The short version of the Depression Anxiety Stress Scale-21 showed excellent values of reliability, and strong internal consistency. The two-factor model with condensation of the constructs anxiety and stress in a single factor was the most acceptable for the adolescent population. PMID:28076595
Walton, David M; Macdermid, Joy C; Nielson, Warren; Teasell, Robert W; Chiasson, Marco; Brown, Lauren
2011-09-01
Clinical measurement. To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Pressure pain threshold testing may be a valuable assessment and prognostic indicator for people with neck pain. To date, most of this research has been completed using algometers that are too resource intensive for routine clinical use. Novice raters (physiotherapy students or clinical physiotherapists) were trained to perform algometry testing over 2 clinically relevant sites: the angle of the upper trapezius and the belly of the tibialis anterior. A convenience sample of normal healthy individuals and a clinical sample of people with neck pain were tested by 2 different raters (all participants) and on 2 different days (healthy participants only). Intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change were calculated. A total of 60 healthy volunteers and 40 people with neck pain were recruited. Intrarater reliability was almost perfect (ICC = 0.94-0.97), interrater reliability was substantial to near perfect (ICC = 0.79-0.90), and test-retest reliability was substantial (ICC = 0.76-0.79). Smaller change was detectable in the trapezius compared to the tibialis anterior. This study provides evidence that novice raters can perform digital algometry with adequate reliability for research and clinical use in people with and without neck pain.
Kidney function endpoints in kidney transplant trials: a struggle for power.
Ibrahim, A; Garg, A X; Knoll, G A; Akbari, A; White, C A
2013-03-01
Kidney function endpoints are commonly used in randomized controlled trials (RCTs) in kidney transplantation (KTx). We conducted this study to estimate the proportion of ongoing RCTs with kidney function endpoints in KTx where the proposed sample size is large enough to detect meaningful differences in glomerular filtration rate (GFR) with adequate statistical power. RCTs were retrieved using the key word "kidney transplantation" from the National Institute of Health online clinical trial registry. Included trials had at least one measure of kidney function tracked for at least 1 month after transplant. We determined the proportion of two-arm parallel trials that had sufficient sample sizes to detect a minimum 5, 7.5 and 10 mL/min difference in GFR between arms. Fifty RCTs met inclusion criteria. Only 7% of the trials were above a sample size of 562, the number needed to detect a minimum 5 mL/min difference between the groups should one exist (assumptions: α = 0.05; power = 80%, 10% loss to follow-up, common standard deviation of 20 mL/min). The result increased modestly to 36% of trials when a minimum 10 mL/min difference was considered. Only a minority of ongoing trials have adequate statistical power to detect between-group differences in kidney function using conventional sample size estimating parameters. For this reason, some potentially effective interventions which ultimately could benefit patients may be abandoned from future assessment. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.
Are There Long-Run Effects of the Minimum Wage?
Sorkin, Isaac
2014-01-01
An empirical consensus suggests that there are small employment effects of minimum wage increases. This paper argues that these are short-run elasticities. Long-run elasticities, which may differ from short-run elasticities, are policy relevant. This paper develops a dynamic industry equilibrium model of labor demand. The model makes two points. First, long-run regressions have been misinterpreted because even if the short- and long-run employment elasticities differ, standard methods would not detect a difference using US variation. Second, the model offers a reconciliation of the small estimated short-run employment effects with the commonly found pass-through of minimum wage increases to product prices. PMID:25937790
Are There Long-Run Effects of the Minimum Wage?
Sorkin, Isaac
2015-04-01
An empirical consensus suggests that there are small employment effects of minimum wage increases. This paper argues that these are short-run elasticities. Long-run elasticities, which may differ from short-run elasticities, are policy relevant. This paper develops a dynamic industry equilibrium model of labor demand. The model makes two points. First, long-run regressions have been misinterpreted because even if the short- and long-run employment elasticities differ, standard methods would not detect a difference using US variation. Second, the model offers a reconciliation of the small estimated short-run employment effects with the commonly found pass-through of minimum wage increases to product prices.
Papadakis, Antonios E; Perisinakis, Kostas; Raissaki, Maria; Damilakis, John
2013-04-01
The aim of the present phantom study was to investigate the effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral computed tomographic (CT) angiographic examinations of pediatric and adult individuals. Four physical anthropomorphic phantoms that represent the average individual as neonate, 1-year-old, 5-year-old, and 10-year-old children and the RANDO phantom that simulates the average adult individual were used. Cylindrical vessels were bored along the brain-equivalent plugs of each physical phantom. To simulate the brain vasculature, vessels of 0.6, 1, 2, and 3 mm in diameter were created. These vessels were filled with contrast medium (CM) solutions at different iodine concentrations, that is, 5.6, 4.2, 2.7, and 1.4 mg I/mL. The phantom heads were scanned at 120, 100, and 80 kV. The applied quality reference tube current-time product values ranged from a minimum of 45 to a maximum of 680. The CT acquisitions were performed on a 16-slice CT scanner using the automatic exposure control system. Image quality was evaluated on the basis of image noise and contrast-to-noise ratio (CNR) between the contrast-enhanced iodinated vessels and the unenhanced regions of interest. Dose reduction was calculated as the percentage difference of the CT dose index value at the quality reference tube current-time product and the CT dose index at the mean modulated tube current-time product. Image noise that was measured using the preset tube current-time product settings varied significantly among the different phantoms (P < 0.0001). Hounsfield unit number of iodinated vessels was linearly related to CM concentration (r² = 0.907) and vessel diameter (r² = 0.918). The Hounsfield unit number of iodinated vessels followed a decreasing trend from the neonate phantom to the adult phantom at all kilovoltage settings. For the same image noise level, a CNR improvement of up to 69% and a dose reduction of up to 61% may be achieved when CT acquisition is performed at 80 kV compared with 120 kV. For the same CNR, a reduction by 25% of the administered CM concentration may be achieved when CT acquisition is performed at 80 kV compared with 120 kV. In cerebral CT angiographic studies, appropriate adjustment of the preset tube current-time product settings is required to achieve the same image noise level among participants of different age. Cerebral CT angiography at 80 kV significantly improves CNR and significantly reduces radiation dose. Moreover, at 80 kV, a considerable reduction of the administered amount of the CM may be reached, thus reducing potential risks for contrast-induced nephropathy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smitherman, C; Chen, B; Samei, E
2014-06-15
Purpose: This work involved a comprehensive modeling of task-based performance of CT across a wide range of protocols. The approach was used for optimization and consistency of dose and image quality within a large multi-vendor clinical facility. Methods: 150 adult protocols from the Duke University Medical Center were grouped into sub-protocols with similar acquisition characteristics. A size based image quality phantom (Duke Mercury Phantom) was imaged using these sub-protocols for a range of clinically relevant doses on two CT manufacturer platforms (Siemens, GE). The images were analyzed to extract task-based image quality metrics such as the Task Transfer Function (TTF),more » Noise Power Spectrum, and Az based on designer nodule task functions. The data were analyzed in terms of the detectability of a lesion size/contrast as a function of dose, patient size, and protocol. A graphical user interface (GUI) was developed to predict image quality and dose to achieve a minimum level of detectability. Results: Image quality trends with variations in dose, patient size, and lesion contrast/size were evaluated and calculated data behaved as predicted. The GUI proved effective to predict the Az values representing radiologist confidence for a targeted lesion, patient size, and dose. As an example, an abdomen pelvis exam for the GE scanner, with a task size/contrast of 5-mm/50-HU, and an Az of 0.9 requires a dose of 4.0, 8.9, and 16.9 mGy for patient diameters of 25, 30, and 35 cm, respectively. For a constant patient diameter of 30 cm, the minimum detected lesion size at those dose levels would be 8.4, 5, and 3.9 mm, respectively. Conclusion: The designed CT protocol optimization platform can be used to evaluate minimum detectability across dose levels and patient diameters. The method can be used to improve individual protocols as well as to improve protocol consistency across CT scanners.« less
Verification of Minimum Detectable Activity for Radiological Threat Source Search
NASA Astrophysics Data System (ADS)
Gardiner, Hannah; Myjak, Mitchell; Baciak, James; Detwiler, Rebecca; Seifert, Carolyn
2015-10-01
The Department of Homeland Security's Domestic Nuclear Detection Office is working to develop advanced technologies that will improve the ability to detect, localize, and identify radiological and nuclear sources from airborne platforms. The Airborne Radiological Enhanced-sensor System (ARES) program is developing advanced data fusion algorithms for analyzing data from a helicopter-mounted radiation detector. This detector platform provides a rapid, wide-area assessment of radiological conditions at ground level. The NSCRAD (Nuisance-rejection Spectral Comparison Ratios for Anomaly Detection) algorithm was developed to distinguish low-count sources of interest from benign naturally occurring radiation and irrelevant nuisance sources. It uses a number of broad, overlapping regions of interest to statistically compare each newly measured spectrum with the current estimate for the background to identify anomalies. We recently developed a method to estimate the minimum detectable activity (MDA) of NSCRAD in real time. We present this method here and report on the MDA verification using both laboratory measurements and simulated injects on measured backgrounds at or near the detection limits. This work is supported by the US Department of Homeland Security, Domestic Nuclear Detection Office, under competitively awarded contract/IAA HSHQDC-12-X-00376. This support does not constitute an express or implied endorsement on the part of the Gov't.
DOE Office of Scientific and Technical Information (OSTI.GOV)
West, W. Geoffrey; Gray, David Clinton
Purpose: To introduce the Joint Commission's requirements for annual diagnostic physics testing of all nuclear medicine equipment, effective 7/1/2014, and to highlight an acceptable methodology for testing lowcontrast resolution of the nuclear medicine imaging system. Methods: The Joint Commission's required diagnostic physics evaluations are to be conducted for all of the image types produced clinically by each scanner. Other accrediting bodies, such as the ACR and the IAC, have similar imaging metrics, but do not emphasize testing low-contrast resolution as it relates clinically. The proposed method for testing low contrast resolution introduces quantitative metrics that are clinically relevant. The acquisitionmore » protocol and calculation of contrast levels will utilize a modified version of the protocol defined in AAPM Report #52. Results: Using the Rose criterion for lesion detection with a SNRpixel = 4.335 and a CNRlesion = 4, the minimum contrast levels for 25.4 mm and 31.8 mm cold spheres were calculated to be 0.317 and 0.283, respectively. These contrast levels are the minimum threshold that must be attained to guard against false positive lesion detection. Conclusion: Low contrast resolution, or detectability, can be properly tested in a manner that is clinically relevant by measuring the contrast level of cold spheres within a Jaszczak phantom using pixel values within ROI's placed in the background and cold sphere regions. The measured contrast levels are then compared to a minimum threshold calculated using the Rose criterion and a CNRlesion = 4. The measured contrast levels must either meet or exceed this minimum threshold to prove acceptable lesion detectability. This research and development activity was performed by the authors while employed at West Physics Consulting, LLC. It is presented with the consent of West Physics, which has authorized the dissemination of the information and/or techniques described in the work.« less
Wafer screening device and methods for wafer screening
Sopori, Bhushan; Rupnowski, Przemyslaw
2014-07-15
Wafer breakage is a serious problem in the photovoltaic industry because a large fraction of wafers (between 5 and 10%) break during solar cell/module fabrication. The major cause of this excessive wafer breakage is that these wafers have residual microcracks--microcracks that were not completely etched. Additional propensity for breakage is caused by texture etching and incomplete edge grinding. To eliminate the cost of processing the wafers that break, it is best to remove them prior to cell fabrication. Some attempts have been made to develop optical techniques to detect microcracks. Unfortunately, it is very difficult to detect microcracks that are embedded within the roughness/texture of the wafers. Furthermore, even if such detection is successful, it is not straightforward to relate them to wafer breakage. We believe that the best way to isolate the wafers with fatal microcracks is to apply a stress to wafers--a stress that mimics the highest stress during cell/module processing. If a wafer survives this stress, it has a high probability of surviving without breakage during cell/module fabrication. Based on this, we have developed a high throughput, noncontact method for applying a predetermined stress to a wafer. The wafers are carried on a belt through a chamber that illuminates the wafer with an intense light of a predetermined intensity distribution that can be varied by changing the power to the light source. As the wafers move under the light source, each wafer undergoes a dynamic temperature profile that produces a preset elastic stress. If this stress exceeds the wafer strength, the wafer will break. The broken wafers are separated early, eliminating cost of processing into cell/module. We will describe details of the system and show comparison of breakage statistics with the breakage on a production line.
Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A
2006-02-01
Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was <0.35 mV-mV, then the detected rhythm was considered noise due to a lead failure. The first ICD-detected episode of lead failure and inappropriate detection from 24 ICD patients with a pace/sense lead failure and all ventricular arrhythmias from 56 ICD patients without a lead failure were selected. The stored data were analyzed to determine the sensitivity and specificity of the algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.
Method and apparatus for controlling electrode gap during vacuum consumable arc remelting
Fisher, R.W.; Maroone, J.P.; Tipping, D.W.; Zanner, F.J.
During vacuum consumable arc remelting the electrode gap between a consumable electrode and a pool of molten metal is difficult to control. The present invention monitors drop shorts by detecting a decrease in the voltage between the consumable electrode and molten pool. The drop shorts and their associated voltage reductions occur as repetitive pulses which are closely correlated to the electrode gap. Thus, the method and apparatus of the present invention controls electrode gap based upon drop shorts detected from the monitored anode-cathode voltage. The number of drop shorts are accumulated, and each time the number of drop shorts reach a predetermined number, the average period between drop shorts is calculated from this predetermined number and the time in which this number is accumulated. This average drop short period is used in a drop short period electrode gap model which determines the actual electrode gap from the drop short. The actual electrode gap is then compared with a desired electrode gap which is selected to produce optimum operating conditions and the velocity of the consumable error is varied based upon the gap error. The consumable electrode is driven according to any prior art system at this velocity. In the preferred embodiment, a microprocessor system is utilized to perform the necessary calculations and further to monitor the duration of each drop short. If any drop short exceeds a preset duration period, the consumable electrode is rapidly retracted a predetermined distance to prevent bonding of the consumable electrode to the molten remelt.
Drop short control of electrode gap
Fisher, Robert W.; Maroone, James P.; Tipping, Donald W.; Zanner, Frank J.
1986-01-01
During vacuum consumable arc remelting the electrode gap between a consumable electrode and a pool of molten metal is difficult to control. The present invention monitors drop shorts by detecting a decrease in the voltage between the consumable electrode and molten pool. The drop shorts and their associated voltage reductions occur as repetitive pulses which are closely correlated to the electrode gap. Thus, the method and apparatus of the present invention controls electrode gap based upon drop shorts detected from the monitored anode-cathode voltage. The number of drop shorts are accumulated, and each time the number of drop shorts reach a predetermined number, the average period between drop shorts is calculated from this predetermined number and the time in which this number is accumulated. This average drop short period is used in a drop short period electrode gap model which determines the actual electrode gap from the drop short. The actual electrode gap is then compared with a desired electrode gap which is selected to produce optimum operating conditions and the velocity of the consumable error is varied based upon the gap error. The consumable electrode is driven according to any prior art system at this velocity. In the preferred embodiment, a microprocessor system is utilized to perform the necessary calculations and further to monitor the duration of each drop short. If any drop short exceeds a preset duration period, the consumable electrode is rapidly retracted a predetermined distance to prevent bonding of the consumable electrode to the molten remelt.
NASA Astrophysics Data System (ADS)
Liu, Bin
2014-07-01
We describe an algorithm that can adaptively provide mixture summaries of multimodal posterior distributions. The parameter space of the involved posteriors ranges in size from a few dimensions to dozens of dimensions. This work was motivated by an astrophysical problem called extrasolar planet (exoplanet) detection, wherein the computation of stochastic integrals that are required for Bayesian model comparison is challenging. The difficulty comes from the highly nonlinear models that lead to multimodal posterior distributions. We resort to importance sampling (IS) to estimate the integrals, and thus translate the problem to be how to find a parametric approximation of the posterior. To capture the multimodal structure in the posterior, we initialize a mixture proposal distribution and then tailor its parameters elaborately to make it resemble the posterior to the greatest extent possible. We use the effective sample size (ESS) calculated based on the IS draws to measure the degree of approximation. The bigger the ESS is, the better the proposal resembles the posterior. A difficulty within this tailoring operation lies in the adjustment of the number of mixing components in the mixture proposal. Brute force methods just preset it as a large constant, which leads to an increase in the required computational resources. We provide an iterative delete/merge/add process, which works in tandem with an expectation-maximization step to tailor such a number online. The efficiency of our proposed method is tested via both simulation studies and real exoplanet data analysis.
Effects of Linking Methods on Detection of DIF.
ERIC Educational Resources Information Center
Kim, Seock-Ho; Cohen, Allan S.
1992-01-01
Effects of the following methods for linking metrics on detection of differential item functioning (DIF) were compared: (1) test characteristic curve method (TCC); (2) weighted mean and sigma method; and (3) minimum chi-square method. With large samples, results were essentially the same. With small samples, TCC was most accurate. (SLD)
A Review on Sensor, Signal, and Information Processing Algorithms (PREPRINT)
2010-01-01
processing [214], ambi- guity surface averaging [215], optimum uncertain field tracking, and optimal minimum variance track - before - detect [216]. In [217, 218...2) (2001) 739–746. [216] S. L. Tantum, L. W. Nolte, J. L. Krolik, K. Harmanci, The performance of matched-field track - before - detect methods using
Practical scheme for optimal measurement in quantum interferometric devices
NASA Astrophysics Data System (ADS)
Takeoka, Masahiro; Ban, Masashi; Sasaki, Masahide
2003-06-01
We apply a Kennedy-type detection scheme, which was originally proposed for a binary communications system, to interferometric sensing devices. We show that the minimum detectable perturbation of the proposed system reaches the ultimate precision bound which is predicted by quantum Neyman-Pearson hypothesis testing. To provide concrete examples, we apply our interferometric scheme to phase shift detection by using coherent and squeezed probe fields.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rose, C.R.; Fortgang, C.M.; Power, J.P.
1992-09-01
The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, {gamma}) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitormore » System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 {mu}s assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rose, C.R.; Fortgang, C.M.; Power, J.P.
1992-01-01
The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, {gamma}) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitormore » System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 {mu}s assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper.« less
JIRICKOVA, A; SULC, J; POHUNEK, P; KITTNAR, O; DOHNALOVA, A; KOFRANEK, J
2009-01-01
Negative expiratory pressure (NEP) applied at the mouth during tidal expiration provides a non-invasive method for detecting expiratory flow limitation. Forty-two children were studied, i.e. 25 children with different respiratory symptoms (R) and 17 without any respiratory symptoms (NR). Children were examined without any sedation. A preset NEP of -5 cm H(2)O was applied; its duration did not exceed duration of tidal expiration. A significance of FL was judged by determining of a flow-limited range (in % of tidal volume). FL was found in 48 % children of R group. No patient of the NR group elicited FL (P<0.001 R vs. NR). The frequency of upper airway collapses was higher in R group (12 children) than in NR group (5 children). In conclusion, a high frequency of tidal FL in the R group was found, while it was not present in NR group. A relatively high frequency of expiratory upper airway collapses was found in both groups, but it did not differ significantly. NEP method represents a reasonable approach for tidal flow limitation testing in non-sedated preschool children.
Generation of Acoustic Self-bending and Bottle Beams by Phase Engineering
2014-07-03
projectile under the action of gravity . We synthesize an acoustic beam propagating along a free-form Bézier curve in air33 by employing a planar speaker...the axial radiation force can be negative, indicating the existence of a pulling force against the beam propagation direction as well as the gravity ...use Legendre transformations to construct the geometric wavefront from a preset beam trajectory. Assume that the geometric wavefront W corresponding to
Control of dental prosthesis system with microcontroller.
Kapidere, M; Müldür, S; Güler, I
2000-04-01
In this study, a microcontroller-based electronic circuit was designed and implemented for dental prosthesis curing system. Heater, compressor and valve were controlled by 8-bit PIC16C64 microcontroller which is programmed using MPASM package. The temperature and time were controlled automatically by preset values which were inputted from keyboard while the pressure was kept constant. Calibration was controlled and the working range was tested. The test results showed that the system provided a good performance.
Grid-translation beam deflection systems for 5-cm and 30-cm diameter Kaufman thrusters.
NASA Technical Reports Server (NTRS)
Lathem, W. C.
1972-01-01
A 5-cm grid translation mechanism has been developed capable of 10-deg beam deflection. A 2026-hour endurance test was run at a preset 10-deg deflection angle, and an extrapolated lifetime of better than 10,000 hours was obtained. Response time data for grid translation are presented. Preliminary results for a 30-cm diameter system are given, and results of a theoretical analysis of a dished grid system are discussed.
Grid-translation beam deflection systems for 5-cm and 30-cm diameter Kaufman thrusters
NASA Technical Reports Server (NTRS)
Lathem, W. C.
1972-01-01
A 5-cm grid translation mechanism has been developed capable of 10 deg beam deflection. A 2026-hour endurance test was run at a preset 10 deg deflection angle and an extrapolated lifetime of better than 10,000 hours obtained. Response time data for grid translation are presented. Preliminary results for a 30-cm diameter system are given and results of a theoretical analysis of a dished grid system are discussed.
Ash bed level control system for a fixed-bed coal gasifier
Fasching, George E.; Rotunda, John R.
1984-01-01
An ash level control system is provided which incorporates an ash level meter to automatically control the ash bed level of a coal gasifier at a selected level. The ash level signal from the ash level meter is updated during each cycle that a bed stirrer travels up and down through the extent of the ash bed level. The ash level signal is derived from temperature measurements made by thermocouples carried by the stirrer as it passes through the ash bed and into the fire zone immediately above the ash bed. The level signal is compared with selected threshold level signal to determine if the ash level is above or below the selected level once each stirrer cycle. A first counter is either incremented or decremented accordingly. The registered count of the first counter is preset in a down counter once each cycle and the preset count is counted down at a selected clock rate. A grate drive is activated to rotate a grate assembly supporting the ash bed for a period equal to the count down period to maintain the selected ash bed level. In order to avoid grate binding, the controller provides a short base operating duration time each stirrer cycle. If the ash bed level drops below a selected low level or exceeds a selected high level, means are provided to notify the operator.
Hanada, Takashi; Katsuta, Shoichi; Yorozu, Atsunori; Maruyama, Koichi
2009-01-01
When using a HDR remote afterloading brachytherapy unit, results of treatment can be greatly influenced by both source position and treatment time. The purpose of this study is to obtain information on the source of the HDR remote afterloading unit, such as its position and time structure, with the use of a simple system consisting of a plastic scintillator block and a charge‐coupled device (CCD) camera. The CCD camera was used for recording images of scintillation luminescence at a fixed rate of 30 frames per second in real time. The source position and time structure were obtained by analyzing the recorded images. For a preset source‐step‐interval of 5 mm, the measured value of the source position was 5.0±1.0mm, with a pixel resolution of 0.07 mm in the recorded images. For a preset transit time of 30 s, the measured value was 30.0±0.6 s, when the time resolution of the CCD camera was 1/30 s. This system enabled us to obtain the source dwell time and movement time. Therefore, parameters such as I192r source position, transit time, dwell time, and movement time at each dwell position can be determined quantitatively using this plastic scintillator‐CCD camera system. PACS number: 87.53.Jw
NASA Technical Reports Server (NTRS)
Peterson, Leslie D. (Inventor); Zimmermann, Richard E. (Inventor)
2001-01-01
An energy absorbing airbag system includes one or more vent valve assemblies for controlling the release of airbag inflation gases to maintain inflation gas pressure within an airbag at a substantially constant pressure during a ride-down of an energy absorbing event. Each vent valve assembly includes a cantilever spring that is flat in an unstressed condition and that has a free end portion. The cantilever spring is secured to an exterior surface of the airbag housing and flexed to cause the second free end portion of the cantilever spring to be pressed, with a preset force, against a vent port or a closure covering the vent port to seal the vent port until inflation gas pressure within the airbag reaches a preselected value determined by the preset force whereupon the free end portion of the cantilever spring is lifted from the vent port by the inflation gases within the airbag to vent the inflation gases from within the airbag. The resilience of the cantilever spring maintains a substantially constant pressure within the airbag during a ride-down portion of an energy absorbing event by causing the cantilever spring to vent gases through the vent port whenever the pressure of the inflation gases reaches the preselected value and by causing the cantilever spring to close the vent port whenever the pressure of the inflation gases falls below the preselected value.
Decision Variants for the Automatic Determination of Optimal Feature Subset in RF-RFE.
Chen, Qi; Meng, Zhaopeng; Liu, Xinyi; Jin, Qianguo; Su, Ran
2018-06-15
Feature selection, which identifies a set of most informative features from the original feature space, has been widely used to simplify the predictor. Recursive feature elimination (RFE), as one of the most popular feature selection approaches, is effective in data dimension reduction and efficiency increase. A ranking of features, as well as candidate subsets with the corresponding accuracy, is produced through RFE. The subset with highest accuracy (HA) or a preset number of features (PreNum) are often used as the final subset. However, this may lead to a large number of features being selected, or if there is no prior knowledge about this preset number, it is often ambiguous and subjective regarding final subset selection. A proper decision variant is in high demand to automatically determine the optimal subset. In this study, we conduct pioneering work to explore the decision variant after obtaining a list of candidate subsets from RFE. We provide a detailed analysis and comparison of several decision variants to automatically select the optimal feature subset. Random forest (RF)-recursive feature elimination (RF-RFE) algorithm and a voting strategy are introduced. We validated the variants on two totally different molecular biology datasets, one for a toxicogenomic study and the other one for protein sequence analysis. The study provides an automated way to determine the optimal feature subset when using RF-RFE.
NASA Astrophysics Data System (ADS)
Skopal, A.; Pribulla, T.; Vaňko, M.; Velič, Z.; Semkov, E.; Wolf, M.; Jones, A.
2004-02-01
We present new photometric observations of EG And, Z And, BF Cyg, CH Cyg, CI Cyg, V1329 Cyg, TX CVn, AG Dra, RW Hya, AG Peg, AX Per, IV Vir and the peculiar M giant V934 Her, which were made in the standard Johnson UBV(R) system. QW Sge was measured in the Kron-Cousin B, V, RC, IC system and for AR Pav we present its new visual estimates. The current issue gathers observations of these objects to December 2003. The main results can be summarized as follows: EG And: The primary minimum in the U light curve (LC) occurred at the end of 2002. A 0.2 -- 0.3 mag brightening in U was detected in the autumn of 2003. Z And: At around August 2002 we detected for the first time a minimum, which is due to eclipse of the active object by the red giant. Measurements from 2003.3 are close to those of a quiescent phase. BF Cyg: In February 2003 a short-term flare developed in the LC. A difference in the depth of recent minima was detected. CH Cyg: This star was in a quiescent phase at a rather bright state. A shallow minimum occurred at ˜ JD 2 452 730, close to the position of the inferior conjunction of the giant in the inner binary of the triple-star model of CH Cyg. CI Cyg: Our observations cover the descending branch of a broad minimum. TX CVn: At/around the beginning of 2003 the star entered a bright stage containing a minimum at ˜ JD 2 452 660. AG Dra: New observations revealed two eruptions, which peaked in October 2002 and 2003 at ˜ 9.3 in U. AR Pav: Our new visual estimates showed a transient disappearance of a wave-like modulation in the star's brightness between the minima at epochs E = 66 and E = 68 and its reappearance. AG Peg: Our measurements from the end of 2001 showed rather complex profile of the LC. RW Hya: Observations follow behaviour of the wave-like variability of quiet symbiotics. AX Per: In May 2003 a 0.5 mag flare was detected following a rapid decrease of the light to a minimum. QW Sge: CCD observations in B, V, RC, IC bands cover a period from 1994.5 to 2003.5. An increase in the star's brightness by about 1 mag was observed in all passbands in 1997. Less pronounced brightening was detected in 1999/2000. V934 Her: Our observations did not show any larger variation in the optical as a reaction to its X-ray activity.
Detection of Leaks in Water Distribution System using Non-Destructive Techniques
NASA Astrophysics Data System (ADS)
Aslam, H.; Kaur, M.; Sasi, S.; Mortula, Md M.; Yehia, S.; Ali, T.
2018-05-01
Water is scarce and needs to be conserved. A considerable amount of water which flows in the water distribution systems was found to be lost due to pipe leaks. Consequently, innovations in methods of pipe leakage detections for early recognition and repair of these leaks is vital to ensure minimum wastage of water in distribution systems. A major component of detection of pipe leaks is the ability to accurately locate the leak location in pipes through minimum invasion. Therefore, this paper studies the leak detection abilities of the three NDT’s: Ground Penetration Radar (GPR) and spectrometer and aims at determining whether these instruments are effective in identifying the leak. An experimental setup was constructed to simulate the underground conditions of water distribution systems. After analysing the experimental data, it was concluded that both the GPR and the spectrometer were effective in detecting leaks in the pipes. However, the results obtained from the spectrometer were not very differentiating in terms of observing the leaks in comparison to the results obtained from the GPR. In addition to this, it was concluded that both instruments could not be used if the water from the leaks had reached on the surface, resulting in surface ponding.
Van Dun, Bram; Wouters, Jan; Moonen, Marc
2009-07-01
Auditory steady-state responses (ASSRs) are used for hearing threshold estimation at audiometric frequencies. Hearing impaired newborns, in particular, benefit from this technique as it allows for a more precise diagnosis than traditional techniques, and a hearing aid can be better fitted at an early age. However, measurement duration of current single-channel techniques is still too long for clinical widespread use. This paper evaluates the practical performance of a multi-channel electroencephalogram (EEG) processing strategy based on a detection theory approach. A minimum electrode set is determined for ASSRs with frequencies between 80 and 110 Hz using eight-channel EEG measurements of ten normal-hearing adults. This set provides a near-optimal hearing threshold estimate for all subjects and improves response detection significantly for EEG data with numerous artifacts. Multi-channel processing does not significantly improve response detection for EEG data with few artifacts. In this case, best response detection is obtained when noise-weighted averaging is applied on single-channel data. The same test setup (eight channels, ten normal-hearing subjects) is also used to determine a minimum electrode setup for 10-Hz ASSRs. This configuration allows to record near-optimal signal-to-noise ratios for 80% of subjects.
NASA Astrophysics Data System (ADS)
Tóbiás, Roland; Furtenbacher, Tibor; Császár, Attila G.
2017-12-01
Cycle bases of graph theory are introduced for the analysis of transition data deposited in line-by-line rovibronic spectroscopic databases. The principal advantage of using cycle bases is that outlier transitions -almost always present in spectroscopic databases built from experimental data originating from many different sources- can be detected and identified straightforwardly and automatically. The data available for six water isotopologues, H
NASA Astrophysics Data System (ADS)
Li, Gang; Zhao, Qing
2017-03-01
In this paper, a minimum entropy deconvolution based sinusoidal synthesis (MEDSS) filter is proposed to improve the fault detection performance of the regular sinusoidal synthesis (SS) method. The SS filter is an efficient linear predictor that exploits the frequency properties during model construction. The phase information of the harmonic components is not used in the regular SS filter. However, the phase relationships are important in differentiating noise from characteristic impulsive fault signatures. Therefore, in this work, the minimum entropy deconvolution (MED) technique is used to optimize the SS filter during the model construction process. A time-weighted-error Kalman filter is used to estimate the MEDSS model parameters adaptively. Three simulation examples and a practical application case study are provided to illustrate the effectiveness of the proposed method. The regular SS method and the autoregressive MED (ARMED) method are also implemented for comparison. The MEDSS model has demonstrated superior performance compared to the regular SS method and it also shows comparable or better performance with much less computational intensity than the ARMED method.
40 CFR 264.304 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... into the leak detection system exceeds the action leakage rate for any sump, the owner or operator must... thereafter, as long as the flow rate in the leak detection system exceeds the action leakage rate, the owner... forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response...
40 CFR 264.253 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... rate into the leak detection system exceeds the action leakage rate for any sump, the owner or operator... thereafter, as long as the flow rate in the leak detection system exceeds the action leakage rate, the owner... must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the...
Mapping Health Data: Improved Privacy Protection With Donut Method Geomasking
Hampton, Kristen H.; Fitch, Molly K.; Allshouse, William B.; Doherty, Irene A.; Gesink, Dionne C.; Leone, Peter A.; Serre, Marc L.; Miller, William C.
2010-01-01
A major challenge in mapping health data is protecting patient privacy while maintaining the spatial resolution necessary for spatial surveillance and outbreak identification. A new adaptive geomasking technique, referred to as the donut method, extends current methods of random displacement by ensuring a user-defined minimum level of geoprivacy. In donut method geomasking, each geocoded address is relocated in a random direction by at least a minimum distance, but less than a maximum distance. The authors compared the donut method with current methods of random perturbation and aggregation regarding measures of privacy protection and cluster detection performance by masking multiple disease field simulations under a range of parameters. Both the donut method and random perturbation performed better than aggregation in cluster detection measures. The performance of the donut method in geoprivacy measures was at least 42.7% higher and in cluster detection measures was less than 4.8% lower than that of random perturbation. Results show that the donut method provides a consistently higher level of privacy protection with a minimal decrease in cluster detection performance, especially in areas where the risk to individual geoprivacy is greatest. PMID:20817785
Mapping health data: improved privacy protection with donut method geomasking.
Hampton, Kristen H; Fitch, Molly K; Allshouse, William B; Doherty, Irene A; Gesink, Dionne C; Leone, Peter A; Serre, Marc L; Miller, William C
2010-11-01
A major challenge in mapping health data is protecting patient privacy while maintaining the spatial resolution necessary for spatial surveillance and outbreak identification. A new adaptive geomasking technique, referred to as the donut method, extends current methods of random displacement by ensuring a user-defined minimum level of geoprivacy. In donut method geomasking, each geocoded address is relocated in a random direction by at least a minimum distance, but less than a maximum distance. The authors compared the donut method with current methods of random perturbation and aggregation regarding measures of privacy protection and cluster detection performance by masking multiple disease field simulations under a range of parameters. Both the donut method and random perturbation performed better than aggregation in cluster detection measures. The performance of the donut method in geoprivacy measures was at least 42.7% higher and in cluster detection measures was less than 4.8% lower than that of random perturbation. Results show that the donut method provides a consistently higher level of privacy protection with a minimal decrease in cluster detection performance, especially in areas where the risk to individual geoprivacy is greatest.
cWINNOWER algorithm for finding fuzzy dna motifs
NASA Technical Reports Server (NTRS)
Liang, S.; Samanta, M. P.; Biegel, B. A.
2004-01-01
The cWINNOWER algorithm detects fuzzy motifs in DNA sequences rich in protein-binding signals. A signal is defined as any short nucleotide pattern having up to d mutations differing from a motif of length l. The algorithm finds such motifs if a clique consisting of a sufficiently large number of mutated copies of the motif (i.e., the signals) is present in the DNA sequence. The cWINNOWER algorithm substantially improves the sensitivity of the winnower method of Pevzner and Sze by imposing a consensus constraint, enabling it to detect much weaker signals. We studied the minimum detectable clique size qc as a function of sequence length N for random sequences. We found that qc increases linearly with N for a fast version of the algorithm based on counting three-member sub-cliques. Imposing consensus constraints reduces qc by a factor of three in this case, which makes the algorithm dramatically more sensitive. Our most sensitive algorithm, which counts four-member sub-cliques, needs a minimum of only 13 signals to detect motifs in a sequence of length N = 12,000 for (l, d) = (15, 4). Copyright Imperial College Press.
cWINNOWER Algorithm for Finding Fuzzy DNA Motifs
NASA Technical Reports Server (NTRS)
Liang, Shoudan
2003-01-01
The cWINNOWER algorithm detects fuzzy motifs in DNA sequences rich in protein-binding signals. A signal is defined as any short nucleotide pattern having up to d mutations differing from a motif of length l. The algorithm finds such motifs if multiple mutated copies of the motif (i.e., the signals) are present in the DNA sequence in sufficient abundance. The cWINNOWER algorithm substantially improves the sensitivity of the winnower method of Pevzner and Sze by imposing a consensus constraint, enabling it to detect much weaker signals. We studied the minimum number of detectable motifs qc as a function of sequence length N for random sequences. We found that qc increases linearly with N for a fast version of the algorithm based on counting three-member sub-cliques. Imposing consensus constraints reduces qc, by a factor of three in this case, which makes the algorithm dramatically more sensitive. Our most sensitive algorithm, which counts four-member sub-cliques, needs a minimum of only 13 signals to detect motifs in a sequence of length N = 12000 for (l,d) = (15,4).
Influencial factors in thermographic analysis in substations
NASA Astrophysics Data System (ADS)
Zarco-Periñán, Pedro J.; Martínez-Ramos, José L.
2018-05-01
Thermography is one of the best predictive maintenance tools available due to its low cost, fast implementation and effectiveness of the results obtained. The detected hot spots enable serious incidents to be prevented, both in the facilities and equipment where they have been located. In accordance with the criticality of such points, the repair is carried out with greater or lesser urgency. However, for detection to remain reliable, the facility must meet a set of requirements that are normally assumed, otherwise hot spots cannot be detected correctly and will subsequently cause unwanted defects. This paper analyses three aspects that influence the reliability of the results obtained: the minimum percentage of load that a circuit must contain in order to be able to locate all the hot spots therein; the minimum waiting time from when an item of equipment or facility is energized until a thermographic inspection can be carried out with a complete guarantee of hot spot detection; and the influence on the generation of hot spots exerted by the tightening torque realized in the assembly process.
Geological Carbon Sequestration: A New Approach for Near-Surface Assurance Monitoring
Wielopolski, Lucian
2011-01-01
There are two distinct objectives in monitoring geological carbon sequestration (GCS): Deep monitoring of the reservoir’s integrity and plume movement and near-surface monitoring (NSM) to ensure public health and the safety of the environment. However, the minimum detection limits of the current instrumentation for NSM is too high for detecting weak signals that are embedded in the background levels of the natural variations, and the data obtained represents point measurements in space and time. A new approach for NSM, based on gamma-ray spectroscopy induced by inelastic neutron scatterings (INS), offers novel and unique characteristics providing the following: (1) High sensitivity with a reducible error of measurement and detection limits, and, (2) temporal- and spatial-integration of carbon in soil that results from underground CO2 seepage. Preliminary field results validated this approach showing carbon suppression of 14% in the first year and 7% in the second year. In addition the temporal behavior of the error propagation is presented and it is shown that for a signal at the level of the minimum detection level the error asymptotically approaches 47%. PMID:21556180
Magnetic Sensors with Picotesla Magnetic Field Sensitivity at Room Temperature
2008-06-01
such small fields require cryogenic cooling such as SQUID sensors, require sophisticated detection systems such as atomic magnetometers and fluxgate ... magnetometers , or have large size and poor low frequency performance such as coil systems. [3-7] The minimum detectable field (the field noise times...Kingdon, "Development of a Combined EMI/ Magnetometer Sensor for UXO Detection," Proc. Symposium on the Applications of Geophysics to Environmental and
Entanglement detection in optical lattices of bosonic atoms with collective measurements
NASA Astrophysics Data System (ADS)
Tóth, Géza
2004-05-01
The minimum requirements for entanglement detection are discussed for a spin chain in which the spins cannot be individually accessed. The methods presented detect entangled states close to a cluster state and a many-body singlet state, and seem to be viable for experimental realization in optical lattices of two-state bosonic atoms. The entanglement criteria are based on entanglement witnesses and on the uncertainty of collective observables.
NASA Astrophysics Data System (ADS)
Sudharsanan, Subramania I.; Mahalanobis, Abhijit; Sundareshan, Malur K.
1990-12-01
Discrete frequency domain design of Minimum Average Correlation Energy filters for optical pattern recognition introduces an implementational limitation of circular correlation. An alternative methodology which uses space domain computations to overcome this problem is presented. The technique is generalized to construct an improved synthetic discriminant function which satisfies the conflicting requirements of reduced noise variance and sharp correlation peaks to facilitate ease of detection. A quantitative evaluation of the performance characteristics of the new filter is conducted and is shown to compare favorably with the well known Minimum Variance Synthetic Discriminant Function and the space domain Minimum Average Correlation Energy filter, which are special cases of the present design.
Minimum resolvable power contrast model
NASA Astrophysics Data System (ADS)
Qian, Shuai; Wang, Xia; Zhou, Jingjing
2018-01-01
Signal-to-noise ratio and MTF are important indexs to evaluate the performance of optical systems. However,whether they are used alone or joint assessment cannot intuitively describe the overall performance of the system. Therefore, an index is proposed to reflect the comprehensive system performance-Minimum Resolvable Radiation Performance Contrast (MRP) model. MRP is an evaluation model without human eyes. It starts from the radiance of the target and the background, transforms the target and background into the equivalent strips,and considers attenuation of the atmosphere, the optical imaging system, and the detector. Combining with the signal-to-noise ratio and the MTF, the Minimum Resolvable Radiation Performance Contrast is obtained. Finally the detection probability model of MRP is given.
1982-08-01
DATA NUMBER OF POINTS 1988 CHANNEL MINIMUM MAXIMUM 1 PHMG -130.13 130.00 2 PS3 -218.12 294.77 3 T3 -341.54 738.15 4 T5 -464.78 623.47 5 PT51 12.317...Continued) CRUISE AND TAKE-OFF MODE DATA I NUMBER OF POINTS 4137 CHANNEL MINIMUM MAXIMUM 1 PHMG -130.13 130.00 2 P53 -218.12 376.60 3 T3 -482.72
Khan, F A; Chenier, T S; Foster, R A; Hewson, J; Scholtz, E L
2018-06-01
Emerging research suggests that the nitric oxide system may play a role in persistent breeding-induced endometritis (PBIE) in the mare. Differences in uterine nitric oxide (NO) levels between mares susceptible or resistant to PBIE and a dose-dependent inhibitory effect of NO on uterine contractility have been demonstrated. The objectives of this study were to investigate the difference in total nitric oxide synthase (NOS) activity of the endometrium between susceptible and resistant mares and the effect of a specific inducible nitric oxide synthase (iNOS) inhibitor on the endometrial NOS activity in vitro. Six susceptible and six resistant mares were selected based on preset criteria and the results of an intrauterine challenge with killed spermatozoa during oestrus. Endometrial biopsy samples were collected 24 hr post-challenge and cultured at 37°C for 24 hr in L-arginine supplemented minimum essential medium with or without a specific iNOS inhibitor (1,400 W dihydrochloride, 1 mM). The medium and the cultured endometrial tissue were collected after 24 hr of culture and assayed for NO and total protein, respectively. Total NO content of the medium, normalized to endometrial tissue wet weight or total protein, was used as a measure of endometrial NOS activity. Non-parametric tests were applied for statistical analysis. Susceptible mares had significantly greater endometrial NOS activity than resistant mares. The iNOS inhibitor treatment significantly reduced NOS activity in endometrial samples derived from susceptible and resistant mares. These findings provide a basis for in vivo testing of specific iNOS inhibitors as preventative or therapeutic options for PBIE in mares. © 2018 Blackwell Verlag GmbH.
Real-Time Feature Tracking Using Homography
NASA Technical Reports Server (NTRS)
Clouse, Daniel S.; Cheng, Yang; Ansar, Adnan I.; Trotz, David C.; Padgett, Curtis W.
2010-01-01
This software finds feature point correspondences in sequences of images. It is designed for feature matching in aerial imagery. Feature matching is a fundamental step in a number of important image processing operations: calibrating the cameras in a camera array, stabilizing images in aerial movies, geo-registration of images, and generating high-fidelity surface maps from aerial movies. The method uses a Shi-Tomasi corner detector and normalized cross-correlation. This process is likely to result in the production of some mismatches. The feature set is cleaned up using the assumption that there is a large planar patch visible in both images. At high altitude, this assumption is often reasonable. A mathematical transformation, called an homography, is developed that allows us to predict the position in image 2 of any point on the plane in image 1. Any feature pair that is inconsistent with the homography is thrown out. The output of the process is a set of feature pairs, and the homography. The algorithms in this innovation are well known, but the new implementation improves the process in several ways. It runs in real-time at 2 Hz on 64-megapixel imagery. The new Shi-Tomasi corner detector tries to produce the requested number of features by automatically adjusting the minimum distance between found features. The homography-finding code now uses an implementation of the RANSAC algorithm that adjusts the number of iterations automatically to achieve a pre-set probability of missing a set of inliers. The new interface allows the caller to pass in a set of predetermined points in one of the images. This allows the ability to track the same set of points through multiple frames.
Scattering of Planetesimals by a Planet
NASA Astrophysics Data System (ADS)
Higuchi, A.; Kokubo, E.; Mukai, T.
2004-05-01
We investigate the scattering process of planetesimals by a planet by numerical orbital integration, aiming at construction of theory for the comet (Oort) cloud formation. The standard scenario of the formation of the Oort cloud can be divided into three dynamical stages:(1)The eccentricity and the aphelion distance of planetesimals are increased by planetary perturbation. (2)The eccentricity is reduced and the perihelion distance is increased by the external forces such as the galactic tide. (3)The inclination is randomized also by the external forces. We model the first stage of this scenario as the restricted three-body problem and calculate the orbital evolution of planetesimals scattered by a planet. There are 4 kinds of outcomes for scattering of planetesimals by a planet: to collide with the planet, to fall onto the central star, to escape from the planetary system, and to remain in bound orbits. Here we consider the escape efficiency as the efficiency of formation of highly eccentric planetesimals, which are candidates for the members of the comet cloud. We obtain the dependence of the escape/collision probability on orbital parameters of the planetesimals and the planet. Using these results, we calculate the efficiencies of escaping from the planetary system and collision with the planet. For example, for the minimum-mass disk model, the inner and massive planet is more efficient to eject planetesimals and increase their eccentricities. Planetesimals with high eccentricities and low inclinations are easier to be ejected from the planetary system. We preset the empirical fitting formulae of these efficiencies as a function of the orbital parameters of the planetesimals and the planets. We apply the results to the solar system and discuss the efficiency of the outer giant planets.
Advanced detection, isolation and accommodation of sensor failures: Real-time evaluation
NASA Technical Reports Server (NTRS)
Merrill, Walter C.; Delaat, John C.; Bruton, William M.
1987-01-01
The objective of the Advanced Detection, Isolation, and Accommodation (ADIA) Program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines by using analytical redundacy to detect sensor failures. The results of a real time hybrid computer evaluation of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 engine control system are determined. Also included are details about the microprocessor implementation of the algorithm as well as a description of the algorithm itself.
Wang, Shiying; Herbst, Elizabeth B.; Mauldin, F. William; Diakova, Galina B.; Klibanov, Alexander L.; Hossack, John A.
2016-01-01
Objectives The objective of this study is to evaluate the minimum microbubble dose for ultrasound molecular imaging to achieve statistically significant detection of angiogenesis in a mouse model. Materials and Methods The pre-burst minus post-burst method was implemented on a Verasonics ultrasound research scanner using a multi-frame compounding pulse inversion imaging sequence. Biotinylated lipid (distearoyl phosphatidylcholine, DSPC-based) microbubbles that were conjugated with anti-vascular endothelial growth factor 2 (VEGFR2) antibody (MBVEGFR2) or isotype control antibody (MBControl) were injected into mice carrying adenocarcinoma xenografts. Different injection doses ranging from 5 × 104 to 1 × 107 microbubbles per mouse were evaluated to determine the minimum diagnostically effective dose. Results The proposed imaging sequence was able to achieve statistically significant detection (p < 0.05, n = 5) of VEGFR2 in tumors with a minimum MBVEGFR2 injection dose of only 5 × 104 microbubbles per mouse (DSPC at 0.053 ng/g mouse body mass). Non-specific adhesion of MBControl at the same injection dose was negligible. Additionally, the targeted contrast ultrasound signal of MBVEGFR2 decreased with lower microbubble doses, while non-specific adhesion of MBControl increased with higher microbubble doses. Conclusions 5 × 104 microbubbles per animal is now the lowest injection dose on record for ultrasound molecular imaging to achieve statistically significant detection of molecular targets in vivo. Findings in this study provide us with further guidance for future developments of clinically translatable ultrasound molecular imaging applications using a lower dose of microbubbles. PMID:27654582
Measuring electrically charged particle fluxes in space using a fiber optic loop sensor
NASA Technical Reports Server (NTRS)
1992-01-01
The purpose of this program was to demonstrate the potential of a fiber optic loop sensor for the measurement of electrically charged particle fluxes in space. The key elements of the sensor are a multiple turn loop of low birefringence, single mode fiber, with a laser diode light source, and a low noise optical receiver. The optical receiver is designed to be shot noise limited, with this being the limiting sensitivity factor for the sensor. The sensing element is the fiber optic loop. Under a magnetic field from an electric current flowing along the axis of the loop, there is a non-vanishing line integral along the fiber optic loop. This causes a net birefringence producing two states of polarization whose phase difference is correlated to magnetic field strength and thus, current in the optical receiver electronic processing. The objectives in this program were to develop a prototype laser diode powered fiber optic sensor. The performance specification of a minimum detectable current density of 1 (mu)amp/sq m-(radical)Hz, should be at the shot noise limit of the detection electronics. OPTRA has successfully built and tested a 3.2 m diameter loop with 137 turns of low birefringence optical fiber and achieved a minimum detectable current density of 5.4 x 10(exp-5) amps/(radical)Hz. If laboratory space considerations were not an issue, with the length of optical fiber available to us, we would have achieved a minimum detectable current density of 4 x 10(exp -7) amps/(radical)Hz.
Davidson, C A; Griffith, C J; Peters, A C; Fielding, L M
1999-01-01
The minimum bacterial detection limits and operator reproducibility of the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test and traditional hygiene swabbing were determined. Areas (100 cm2) of food grade stainless steel were separately inoculated with known levels of Staphylococcus aureus (NCTC 6571) and Escherichia coli (ATCC 25922). Surfaces were sampled either immediately after inoculation while still wet, or after 60 min when completely dry. For both organisms the minimum detection limit of the ATP Clean-Tracetrade mark Rapid Cleanliness Test was 10(4) cfu/100 cm2 (p < 0.05) and was the same for wet and dry surfaces. Both organism type and surface status (i.e. wet or dry) influenced the minimum detection limits of hygiene swabbing, which ranged from 10(2) cfu/100 cm2 to >10(7) cfu/100 cm2. Hygiene swabbing percentage recovery rates for both organisms were less than 0.1% for dried surfaces but ranged from 0.33% to 8.8% for wet surfaces. When assessed by six technically qualified operators, the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test gave superior reproducibility for both clean and inoculated surfaces, giving mean coefficients of variation of 24% and 32%, respectively. Hygiene swabbing of inoculated surfaces gave a mean CV of 130%. The results are discussed in the context of hygiene monitoring within the food industry. Copyright 1999 John Wiley & Sons, Ltd.
The Impact of a City-Level Minimum-Wage Policy on Supermarket Food Prices in Seattle-King County.
Otten, Jennifer J; Buszkiewicz, James; Tang, Wesley; Aggarwal, Anju; Long, Mark; Vigdor, Jacob; Drewnowski, Adam
2017-09-09
Background : Many states and localities throughout the U.S. have adopted higher minimum wages. Higher labor costs among low-wage food system workers could result in higher food prices. Methods : Using a market basket of 106 foods, food prices were collected at affected chain supermarket stores in Seattle and same-chain unaffected stores in King County (n = 12 total, six per location). Prices were collected at 1 month pre- (March 2015) and 1-month post-policy enactment (May 2015), then again 1-year post-policy enactment (May 2016). Unpaired t-tests were used to detect price differences by location at fixed time while paired t-tests were used to detect price difference across time with fixed store chain. A multi-level, linear differences-in-differences model, was used to detect the changes in the average market basket item food prices over time across regions, overall and by food group. Results : There were no significant differences in overall market basket or item-level costs at one-month (-$0.01, SE = 0.05, p = 0.884) or one-year post-policy enactment (-$0.02, SE = 0.08, p = 0.772). No significant increases were observed by food group. Conclusions : There is no evidence of change in supermarket food prices by market basket or increase in prices by food group in response to the implementation of Seattle's minimum wage ordinance.
NASA Astrophysics Data System (ADS)
Wilson, Jennifer G.; Cummins, Kenneth L.; Krider, E. Philip
2009-12-01
The NASA Kennedy Space Center (KSC) and Air Force Eastern Range (ER) use data from two cloud-to-ground (CG) lightning detection networks, the Cloud-to-Ground Lightning Surveillance System (CGLSS) and the U.S. National Lightning Detection Network™ (NLDN), and a volumetric lightning mapping array, the Lightning Detection and Ranging (LDAR) system, to monitor and characterize lightning that is potentially hazardous to launch or ground operations. Data obtained from these systems during June-August 2006 have been examined to check the classification of small, negative CGLSS reports that have an estimated peak current, ∣Ip∣ less than 7 kA, and to determine the smallest values of Ip that are produced by first strokes, by subsequent strokes that create a new ground contact (NGC), and by subsequent strokes that remain in a preexisting channel (PEC). The results show that within 20 km of the KSC-ER, 21% of the low-amplitude negative CGLSS reports were produced by first strokes, with a minimum Ip of -2.9 kA; 31% were by NGCs, with a minimum Ip of -2.0 kA; and 14% were by PECs, with a minimum Ip of -2.2 kA. The remaining 34% were produced by cloud pulses or lightning events that we were not able to classify.
Resource sharing on CSMA/CD networks in the presence of noise. M.S. Thesis
NASA Technical Reports Server (NTRS)
Dinschel, Duane Edward
1987-01-01
Resource sharing on carrier sense multiple access with collision detection (CSMA/CD) networks can be accomplished by using window-control algorithms for bus contention. The window-control algorithms are designed to grant permission to transmit to the station with the minimum contention parameter. Proper operation of the window-control algorithm requires that all stations sense the same state of the newtork in each contention slot. Noise causes the state of the network to appear as a collision. False collisions can cause the window-control algorithm to terminate without isolating any stations. A two-phase window-control protocol and approximate recurrence equation with noise as a parameter to improve the performance of the window-control algorithms in the presence of noise are developed. The results are compared through simulation, with the approximate recurrence equation yielding the best overall performance. Noise is even a bigger problem when it is not detected by all stations. In such cases it is possible for the window boundaries of the contending stations to become out of phase. Consequently, it is possible to isolate a station other than the one with the minimum contention parameter. To guarantee proper isolation of the minimum, a broadcast phase must be added after the termination of the algorithm. The protocol required to correct the window-control algorithm when noise is not detected by all stations is discussed.
STS-48 crew poses for onboard (inflight) portrait on OV-103's middeck
1991-09-15
STS048-21-04 (15 Sept 1991) --- The five astronauts pose on the Space Shuttle Discovery's middeck for the traditional in-flight crew portrait. Astronaut John O. Creighton, mission commander, is at center. Others are (front row, left to right) Kenneth S. Reightler, pilot; and James F. Buchli, mission specialist; and (rear row, left to right) astronauts Mark N. Brown and Charles D. (Sam) Gemar, both mission specialists. The image was photographed with a pre-set 35mm camera.
Study of sleeper’s impact on the deep-water pipeline lateral global buckling
NASA Astrophysics Data System (ADS)
Liu, Wenbin; Li, Bin
2017-08-01
Pipelines are the most important transportation way for offshore oil and gas, and the lateral buckling is the main global buckling form for deep-water pipelines. The sleeper is an economic and efficient device to trigger the lateral buckling in preset location. This paper analyzed the lateral buckling features for on-bottom pipeline and pipeline with sleeper. The stress and strain variation during buckling process is shown to reveal the impact of sleeper on buckling.
The Effects of High-Altitude Electromagnetic Pulse (HEMP) on Telecommunications Assets
1988-06-01
common to a whole class of switches. 5ESS switch software controls the operating system, call processing, and system administration andgmaintenance...LEVEL (ky/rn)3 (a). Mean Fraction of Preset Calls Dropped Due to Induced Transients3 1.0 W -o35kVhM (36 EVENTS) 5-40 kV/M (13 EVENTS) IAUTOMATIC ...eel PERIPHRAL UNIT BUS,IMNA The entire 4ESS system is controlled by the 1A processor. The processor monitors and controls the operation of the
Design on automatic rolling system for agricultural greenhouse
NASA Astrophysics Data System (ADS)
Fu, Li; Fu, Xiuwei; Zhang, Yanxiao
2018-03-01
The automatic rolling system of agricultural greenhouse is introduced in this paper. The opening degree of greenhouse according to changes in light intensity and temperature is adjusted. When the current is too large or the motor is blocked or lost, the buzzer is alarmed and warned someone the controlling system badly. When the temperature is higher than the default value, the fan is moved by the micro-controller controls, otherwise the heating rod so that the temperature reaches the preset range.
A method for monitoring nuclear absorption coefficients of aviation fuels
NASA Technical Reports Server (NTRS)
Sprinkle, Danny R.; Shen, Chih-Ping
1989-01-01
A technique for monitoring variability in the nuclear absorption characteristics of aviation fuels has been developed. It is based on a highly collimated low energy gamma radiation source and a sodium iodide counter. The source and the counter assembly are separated by a geometrically well-defined test fuel cell. A computer program for determining the mass attenuation coefficient of the test fuel sample, based on the data acquired for a preset counting period, has been developed and tested on several types of aviation fuel.
Balancing the balanced scorecard for a New Zealand mental health service.
Coop, Colleen F
2006-05-01
Given the high prevalence of mental disorders, there is a need to evaluate mental health services to ensure they are efficient, effective, responsive and accessible. One method that is being used is the "balanced scorecard" which uses performance indicators in four quadrants to assess various dimensions of service provision. This case study describes the steps taken by a New Zealand mental health service to improve service management through greater use of key performance indicators in relation to preset targets using this approach.
A risk-based coverage model for video surveillance camera control optimization
NASA Astrophysics Data System (ADS)
Zhang, Hongzhou; Du, Zhiguo; Zhao, Xingtao; Li, Peiyue; Li, Dehua
2015-12-01
Visual surveillance system for law enforcement or police case investigation is different from traditional application, for it is designed to monitor pedestrians, vehicles or potential accidents. Visual surveillance risk is defined as uncertainty of visual information of targets and events monitored in present work and risk entropy is introduced to modeling the requirement of police surveillance task on quality and quantity of vide information. the prosed coverage model is applied to calculate the preset FoV position of PTZ camera.
Versatile IEEE-488 data acquisition and control routines for a diode array spectrophotometer
Shiundu, Paul M.
1991-01-01
The UV-visible diode array spectrophotometer is a work-horse instrument for many laboratories. This article provides simple data acquisition and control routines in Microsoft QuickBasic for a HP-8452A diode array spectrophotometer interfaced to an IBM PC/XT/AT, or compatible, microcomputer. These allow capture of full spectra and measure absorbance at one or several wavelengths at preset time intervals. The variance in absorbance at each wavelength is available as an option. PMID:18924888
Instrumentation Automation for Concrete Structures; Report 1: Instrumentation Automation Techniques
1986-12-01
The internat.i..onal measuring system sets up independent standards for t:hese fundamental quanti ties. All other quanti ties (force, acceleration...measurement systems are typically composed of several fundamental performing a special function (Figure 1). 3 accuracy of a quantitative measurement is...equiJ2.ID_g_:)1t 2 J, A fundament ’’ J function of ~" i1 ’r. ’’i::rumentation system is to prese~t desired measurement data to Lne user in a form that
Terrain Traversing Device Having a Wheel with Microhooks
NASA Technical Reports Server (NTRS)
Parness, Aaron (Inventor); McKenzie, Clifford F. (Inventor)
2014-01-01
A terrain traversing device includes an annular rotor element with a plurality of co-planar microspine hooks arranged on the periphery of the annular rotor element. Each microspine hook has an independently flexible suspension configuration that permits the microspine hook to initially engage an irregularity in a terrain surface at a preset initial engagement angle and subsequently engage the irregularity with a continuously varying engagement angle when the annular rotor element is rotated for urging the terrain traversing device to traverse a terrain surface.
HST images of the eclipsing pulsar B1957+20
NASA Technical Reports Server (NTRS)
Fruchter, Andrew S.; Bookbinder, Jay; Bailyn, Charles D.
1995-01-01
We have obtained images of the eclipsing pulsar binary PSR B1957+20 using the Planetary Camera of the Hubble Space Telescope (HST). The high spatial resolution of this instrument has allowed us to separate the pulsar system from a nearby background star which has confounded ground-based observations of this system near optical minimum. Our images limit the temperature of the backside of the companion to T less than or approximately = 2800 K, about a factor of 2 less than the average temperature of the side of the companion facing the pulsar, and provide a marginal detection of the companion at optical minimum. The magnitude of this detection is consistent with previous work which suggests that the companion nearly fills its Roche lobe and is supported through tidal dissipation.
NASA Astrophysics Data System (ADS)
MacMahon, Heber; Vyborny, Carl; Powell, Gregory; Doi, Kunio; Metz, Charles E.
1984-08-01
In digital radiography the pixel size used determines the potential spatial resolution of the system. The need for spatial resolution varies depending on the subject matter imaged. In many areas, including the chest, the minimum spatial resolution requirements have not been determined. Sarcoidosis is a disease which frequently causes subtle interstitial infiltrates in the lungs. As the initial step in an investigation designed to determine the minimum pixel size required in digital chest radiographic systems, we have studied 1 mm pixel digitized images on patients with early pulmonary sarcoidosis. The results of this preliminary study suggest that neither mild interstitial pulmonary infiltrates nor other abnormalities such as pneumothoraces may be detected reliably with 1 mm pixel digital images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mauk, F.J.; Christensen, D.H.
1980-09-01
Probabilistic estimations of earthquake detection and location capabilities for the states of Illinois, Indiana, Kentucky, Ohio and West Virginia are presented in this document. The algorithm used in these epicentrality and minimum-magnitude estimations is a version of the program NETWORTH by Wirth, Blandford, and Husted (DARPA Order No. 2551, 1978) which was modified for local array evaluation at the University of Michigan Seismological Observatory. Estimations of earthquake detection capability for the years 1970 and 1980 are presented in four regional minimum m/sub b/ magnitude contour maps. Regional 90% confidence error ellipsoids are included for m/sub b/ magnitude events from 2.0more » through 5.0 at 0.5 m/sub b/ unit increments. The close agreement between these predicted epicentral 90% confidence estimates and the calculated error ellipses associated with actual earthquakes within the studied region suggest that these error determinations can be used to estimate the reliability of epicenter location. 8 refs., 14 figs., 2 tabs.« less
Zhang, Qing; Zhu, Liang; Feng, Hanhua; Ang, Simon; Chau, Fook Siong; Liu, Wen-Tso
2006-01-18
This paper reported the development of a microfludic device for the rapid detection of viable and nonviable microbial cells through dual labeling by fluorescent in situ hybridization (FISH) and quantum dots (QDs)-labeled immunofluorescent assay (IFA). The coin sized device consists of a microchannel and filtering pillars (gap=1-2 microm) and was demonstrated to effectively trap and concentrate microbial cells (i.e. Giardia lamblia). After sample injection, FISH probe solution and QDs-labeled antibody solution were sequentially pumped into the device to accelerate the fluorescent labeling reactions at optimized flow rates (i.e. 1 and 20 microL/min, respectively). After 2 min washing for each assay, the whole process could be finished within 30 min, with minimum consumption of labeling reagents and superior fluorescent signal intensity. The choice of QDs 525 for IFA resulted in bright and stable fluorescent signal, with minimum interference with the Cy3 signal from FISH detection.
Reduction of Calcofluor in Solithane Conformal Coatings of Printed Wiring Boards
NASA Technical Reports Server (NTRS)
Miller, Michael K.
1997-01-01
An investigation on the outgassing of a pigment employed as a fluorescent medium in conformal coatings has been performed. The conformal coatings in question are used to protect printed wiring boards from environmental hazards such as dust and moisture. The pigment is included in the coating at low concentration to allow visual inspection of the conformal coating for flaw detection. Calcofluor, the fluorescent pigment has been found to be a significant outgasser under vacuum conditions and a potential source of contamination to flight hardware. A minimum acceptable concentration of Calcofluor for flaw detection is desirable. Tests have been carried out using a series of Solithane(TM) conformal coating samples, with progressively lower Calcofluor concentrations, to determine the minimum required concentration of Calcofluor. It was found that the concentration of Calcofluor could be reduced from 0.115% to 0.0135% without significant loss in the ability to detect flaws, while at the same time significant reductions in Calcofluor outgassing and possible contamination of systems could be realized.
NASA Astrophysics Data System (ADS)
Wang, Yi; Zhang, Ao; Ma, Jing
2017-07-01
Minimum-shift keying (MSK) has the advantages of constant envelope, continuous phase, and high spectral efficiency, and it is applied in radio communication and optical fiber communication. MSK modulation of coherent detection is proposed in the ground-to-satellite laser communication system; in addition, considering the inherent noise of uplink, such as intensity scintillation and beam wander, the communication performance of the MSK modulation system with coherent detection is studied in the uplink ground-to-satellite laser. Based on the gamma-gamma channel model, the closed form of bit error rate (BER) of MSK modulation with coherent detection is derived. In weak, medium, and strong turbulence, the BER performance of the MSK modulation system is simulated and analyzed. To meet the requirements of the ground-to-satellite coherent MSK system to optimize the parameters and configuration of the transmitter and receiver, the influence of the beam divergence angle, the zenith angle, the transmitter beam radius, and the receiver diameter are studied.
Real-Time Detection of Telomerase in a Microelectromechanical Systems Platform
2005-05-01
contains color images. 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT UU 18. NUMBER OF PAGES 147 19a...Telomerase accomplishes this by alleviating the “end-replication problem” (6,10,14,23,33,43). First described by Hayflick in 1965, the end-replication...were produced to determine the minimum detection limit of the ABI Prism 7000 as an optical fluorescent detection device. In addition, I wanted to
2013-09-30
performance of algorithms detecting dives, strokes , clicks, respiration and gait changes. (ii) Calibration errors: Size and power constraints in...acceptance parameters used to detect and classify events. For example, swim stroke detection requires parameters defining the minimum magnitude and the min...and max duration of a stroke . Species dependent parameters can be selected from existing DTAG data but other parameters depend on the size of the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chida, K.; Yamauchi, Y.; Arakawa, T.
2013-12-04
We performed the resistively-detected nuclear magnetic resonance (RDNMR) to study the electron spin polarization in the non-equilibrium quantum Hall regime. By measuring the Knight shift, we derive source-drain bias voltage dependence of the electron spin polarization in quantum wires. The electron spin polarization shows minimum value around the threshold voltage of the dynamic nuclear polarization.
40 CFR 63.7525 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... tolerance of 1.27 centimeters of water or a transducer with a minimum tolerance of 1 percent of the pressure... use a fabric filter bag leak detection system to comply with the requirements of this subpart, you must install, calibrate, maintain, and continuously operate a bag leak detection system as specified in...
Haas, Derek A; Eslinger, Paul W; Bowyer, Theodore W; Cameron, Ian M; Hayes, James C; Lowrey, Justin D; Miley, Harry S
2017-11-01
The Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests and mandates development of verification measures to detect treaty violations. One verification measure is detection of radioactive xenon isotopes produced in the fission of actinides. The International Monitoring System (IMS) currently deploys automated radioxenon systems that can detect four radioxenon isotopes. Radioxenon systems with lower detection limits are currently in development. Historically, the sensitivity of radioxenon systems was measured by the minimum detectable concentration for each isotope. In this paper we analyze the response of radioxenon systems using rigorous metrics in conjunction with hypothetical representative releases indicative of an underground nuclear explosion instead of using only minimum detectable concentrations. Our analyses incorporate the impact of potential spectral interferences on detection limits and the importance of measuring isotopic ratios of the relevant radioxenon isotopes in order to improve discrimination from background sources particularly for low-level releases. To provide a sufficient data set for analysis, hypothetical representative releases are simulated every day from the same location for an entire year. The performance of three types of samplers are evaluated assuming they are located at 15 IMS radionuclide stations in the region of the release point. The performance of two IMS-deployed samplers and a next-generation system is compared with proposed metrics for detection and discrimination using representative releases from the nuclear test site used by the Democratic People's Republic of Korea. Copyright © 2017 Elsevier Ltd. All rights reserved.
Structure for identifying, locating and quantifying physical phenomena
Richardson, John G.
2006-10-24
A method and system for detecting, locating and quantifying a physical phenomena such as strain or a deformation in a structure. A minimum resolvable distance along the structure is selected and a quantity of laterally adjacent conductors is determined. Each conductor includes a plurality of segments coupled in series which define the minimum resolvable distance along the structure. When a deformation occurs, changes in the defined energy transmission characteristics along each conductor are compared to determine which segment contains the deformation.
Richardson, John G.
2006-01-24
A method and system for detecting, locating and quantifying a physical phenomena such as strain or a deformation in a structure. A minimum resolvable distance along the structure is selected and a quantity of laterally adjacent conductors is determined. Each conductor includes a plurality of segments coupled in series which define the minimum resolvable distance along the structure. When a deformation occurs, changes in the defined energy transmission characteristics along each conductor are compared to determine which segment contains the deformation.
A Study of the World’s Naval Surface-to-Air Missile Defense Systems.
1984-12-01
in various installations to foreign radars, such as the Contraves SeaHunter, SanGiogio NA9. A light- weight , three-round launcher (based on the short... Losses . . . . . . . . . . . . . . 22 7- B. MINIMUM SIGNAL DETECTION . . . . . . . . . . . 22 1. Noise Figure F ......... ..... 25 2. Minimum Signal-to...idealized radar equation becomes Pr 4>, 2 (2. 11) a, 4 2. S Losses There are many sources of power loss in the echo, and these losses reduce the energy of
NASA Technical Reports Server (NTRS)
Eaton, J. E.; Cherepashchuk, A. M.; Khaliullin, K. F.
1982-01-01
The 1200-1900 angstrom region and fine error sensor observations in the optical for V444 Cyg were continuously observed. More than half of a primary minimum and almost a complete secondary minimum were observed. It is found that the time of minimum for the secondary eclipse is consistent with that for primary eclipse, and the ultraviolet times of minimum are consistent with the optical ones. The spectrum shows a considerable amount of phase dependence. The general shaps and depths of the light curves for the FES signal and the 1565-1900 angstrom continuum are similar to those for the blue continuum. The FES, however, detected an atmospheric eclipse in line absorption at about the phase the NIV absorption was strongest. It is suggested that there is a source of continuum absorption shortward of 1460 angstrom which exists throughout a large part of the extended atmosphere and which, by implication, must redden considerably the ultraviolet continuua of WN stars. A fairly high degree of ionization for the inner part of the WN star a atmosphere is implied.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of the Act. (f) Detection limit means the minimum concentration of an analyte (substance) that can be measured and reported with a 99% confidence that the analyte concentration is greater than zero as...
Code of Federal Regulations, 2014 CFR
2014-07-01
... of the Act. (f) Detection limit means the minimum concentration of an analyte (substance) that can be measured and reported with a 99% confidence that the analyte concentration is greater than zero as...
Code of Federal Regulations, 2011 CFR
2011-07-01
... of the Act. (f) Detection limit means the minimum concentration of an analyte (substance) that can be measured and reported with a 99% confidence that the analyte concentration is greater than zero as...
Code of Federal Regulations, 2012 CFR
2012-07-01
... of the Act. (f) Detection limit means the minimum concentration of an analyte (substance) that can be measured and reported with a 99% confidence that the analyte concentration is greater than zero as...
Code of Federal Regulations, 2013 CFR
2013-07-01
... of the Act. (f) Detection limit means the minimum concentration of an analyte (substance) that can be measured and reported with a 99% confidence that the analyte concentration is greater than zero as...
Minimum time search in uncertain dynamic domains with complex sensorial platforms.
Lanillos, Pablo; Besada-Portas, Eva; Lopez-Orozco, Jose Antonio; de la Cruz, Jesus Manuel
2014-08-04
The minimum time search in uncertain domains is a searching task, which appears in real world problems such as natural disasters and sea rescue operations, where a target has to be found, as soon as possible, by a set of sensor-equipped searchers. The automation of this task, where the time to detect the target is critical, can be achieved by new probabilistic techniques that directly minimize the Expected Time (ET) to detect a dynamic target using the observation probability models and actual observations collected by the sensors on board the searchers. The selected technique, described in algorithmic form in this paper for completeness, has only been previously partially tested with an ideal binary detection model, in spite of being designed to deal with complex non-linear/non-differential sensorial models. This paper covers the gap, testing its performance and applicability over different searching tasks with searchers equipped with different complex sensors. The sensorial models under test vary from stepped detection probabilities to continuous/discontinuous differentiable/non-differentiable detection probabilities dependent on distance, orientation, and structured maps. The analysis of the simulated results of several static and dynamic scenarios performed in this paper validates the applicability of the technique with different types of sensor models.
Zhou, Chennan; Zhang, Xueyin; Huang, Xinxin; Guo, Xishan; Cai, Qiang; Zhu, Songming
2014-01-01
A colloidal gold immunochromatographic assay (GICA) was developed for rapid detection of chloramphenicol (CAP) residues in aquatic products. A nitrocellulose (NC) membrane was used as the carrier, and the polyclonal CAP antibody was used as the marker protein. The average diameter of as-prepared colloidal gold nanoparticles (AuNPs) was about 20 nm. The optimal pH value of colloidal gold solutions and the amount of the antibody of CAP were 8.0 and 7.2 μg/mL, respectively. The CAP antibody was immobilized onto the conjugate pad after purification. The CAP conjugate and goat anti-rabbit IgG (secondary antibody) were coated onto the NC membrane. Next, the non-specific sites were blocked with 1% bovine serum albumin. The minimum detectable concentration of CAP in standard solution is 0.5 ng/mL, with good reproducibility. For the real samples from crucian carps injected with a single-dose of CAP in the dorsal muscles, the minimum detectable concentration of CAP residues was 0.5 μg/kg. The chromatographic analysis time was less than 10 min, and the strip had a long storage lifetime of more than 90 days at different temperatures. The strips provide a means for rapid detection of CAP residues in aquatic products. PMID:25412221
Minimum Time Search in Uncertain Dynamic Domains with Complex Sensorial Platforms
Lanillos, Pablo; Besada-Portas, Eva; Lopez-Orozco, Jose Antonio; de la Cruz, Jesus Manuel
2014-01-01
The minimum time search in uncertain domains is a searching task, which appears in real world problems such as natural disasters and sea rescue operations, where a target has to be found, as soon as possible, by a set of sensor-equipped searchers. The automation of this task, where the time to detect the target is critical, can be achieved by new probabilistic techniques that directly minimize the Expected Time (ET) to detect a dynamic target using the observation probability models and actual observations collected by the sensors on board the searchers. The selected technique, described in algorithmic form in this paper for completeness, has only been previously partially tested with an ideal binary detection model, in spite of being designed to deal with complex non-linear/non-differential sensorial models. This paper covers the gap, testing its performance and applicability over different searching tasks with searchers equipped with different complex sensors. The sensorial models under test vary from stepped detection probabilities to continuous/discontinuous differentiable/non-differentiable detection probabilities dependent on distance, orientation, and structured maps. The analysis of the simulated results of several static and dynamic scenarios performed in this paper validates the applicability of the technique with different types of sensor models. PMID:25093345
A noise power spectrum study of a new model‐based iterative reconstruction system: Veo 3.0
Li, Guang; Liu, Xinming; Dodge, Cristina T.; Jensen, Corey T.
2016-01-01
The purpose of this study was to evaluate performance of the third generation of model‐based iterative reconstruction (MBIR) system, Veo 3.0, based on noise power spectrum (NPS) analysis with various clinical presets over a wide range of clinically applicable dose levels. A CatPhan 600 surrounded by an oval, fat‐equivalent ring to mimic patient size/shape was scanned 10 times at each of six dose levels on a GE HD 750 scanner. NPS analysis was performed on images reconstructed with various Veo 3.0 preset combinations for comparisons of those images reconstructed using Veo 2.0, filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASiR). The new Target Thickness setting resulted in higher noise in thicker axial images. The new Texture Enhancement function achieved a more isotropic noise behavior with less image artifacts. Veo 3.0 provides additional reconstruction options designed to allow the user choice of balance between spatial resolution and image noise, relative to Veo 2.0. Veo 3.0 provides more user selectable options and in general improved isotropic noise behavior in comparison to Veo 2.0. The overall noise reduction performance of both versions of MBIR was improved in comparison to FBP and ASiR, especially at low‐dose levels. PACS number(s): 87.57.‐s, 87.57.Q‐, 87.57.C‐, 87.57.nf, 87.57.C‐, 87.57.cm PMID:27685118
Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya
2014-04-01
To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.
Implantable automatic scanning pacemaker for termination of supraventricular tachycardia.
Spurrell, R A; Nathan, A W; Bexton, R S; Hellestrand, K J; Nappholz, T; Camm, A J
1982-03-01
Thirteen patients suffering from reentrant supraventricular tachycardia have undergone implantation of a scanning extrastimulus pacemaker. This pacemaker is fully implanted and automatic, and it requires no external control device to activate or control it. The pacemaker is activated when tachycardia occurs. After four cycles an extrastimulus is induced with a preset coupling time from a sensed intracardiac potential, and every four cycles thereafter a further extrastimulus occurs, but on each occasion there is a decrement in coupling cycle by 6 ms until 90 ms of the cardiac cycle has been scanned by extrastimuli. When necessary, two extrastimuli can be introduced with a fixed but preset coupling time between them. Every four beats two extrastimuli are induced but the coupling time between the spontaneous cardiac potential and the first stimulus is decreased by 6 ms until 90 ms of the cardiac cycle has been scanned. The coupling time between the two stimuli is fixed throughout the scan. When termination of tachycardia occurs the successful timing variables are retained in the pacemaker memory so that at the onset of the next episode of tachycardia these settings are used first. Pacemaker pulse width, sensitivity, tachycardia trigger rate, coupling intervals for both stimuli and the use of single or double extrastimuli are all programmable transcutaneously. Three patients required single, and seven patients double ventricular premature stimuli; three patients required double atrial premature stimuli for termination of tachycardia. Despite frequent attacks of tachycardia before implantation, only two patients had a sustained attack of tachycardia after pacemaker implantation.
Controlled weather balloon ascents and descents for atmospheric research and climate monitoring
Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.
2017-01-01
In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth’s surface to about 35 km (3–5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent. PMID:29263765
NASA Astrophysics Data System (ADS)
Xia, Huanxiong; Xiang, Dong; Yang, Wang; Mou, Peng
2014-12-01
Low-temperature plasma technique is one of the critical techniques in IC manufacturing process, such as etching and thin-film deposition, and the uniformity greatly impacts the process quality, so the design for the plasma uniformity control is very important but difficult. It is hard to finely and flexibly regulate the spatial distribution of the plasma in the chamber via controlling the discharge parameters or modifying the structure in zero-dimensional space, and it just can adjust the overall level of the process factors. In the view of this problem, a segmented non-uniform dielectric module design solution is proposed for the regulation of the plasma profile in a CCP chamber. The solution achieves refined and flexible regulation of the plasma profile in the radial direction via configuring the relative permittivity and the width of each segment. In order to solve this design problem, a novel simulation-based auto-design approach is proposed, which can automatically design the positional sequence with multi independent variables to make the output target profile in the parameterized simulation model approximate the one that users preset. This approach employs an idea of quasi-closed-loop control system, and works in an iterative mode. It starts from initial values of the design variable sequences, and predicts better sequences via the feedback of the profile error between the output target profile and the expected one. It never stops until the profile error is narrowed in the preset tolerance.
Controlled weather balloon ascents and descents for atmospheric research and climate monitoring.
Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F; Hall, Emrys G; Jordan, Allen F
2016-01-01
In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.
NASA Astrophysics Data System (ADS)
Krupinski, Elizabeth A.; Berbaum, Kevin S.; Caldwell, Robert; Schartz, Kevin M.
2012-02-01
Radiologists are reading more cases with more images, especially in CT and MRI and thus working longer hours than ever before. There have been concerns raised regarding fatigue and whether it impacts diagnostic accuracy. This study measured the impact of reader visual fatigue by assessing symptoms, visual strain via dark focus of accommodation, and diagnostic accuracy. Twenty radiologists and 20 radiology residents were given two diagnostic performance tests searching CT chest sequences for a solitary pulmonary nodule before (rested) and after (tired) a day of clinical reading. 10 cases used free search and navigation, and the other 100 cases used preset scrolling speed and duration. Subjects filled out the Swedish Occupational Fatigue Inventory (SOFI) and the oculomotor strain subscale of the Simulator Sickness Questionnaire (SSQ) before each session. Accuracy was measured using ROC techniques. Using Swensson's technique yields an ROC area = 0.86 rested vs. 0.83 tired, p (one-tailed) = 0.09. Using Swensson's LROC technique yields an area = 0.73 rested vs. 0.66 tired, p (one-tailed) = 0.09. Using Swensson's Loc Accuracy technique yields an area = 0.77 rested vs. 0.72 tired, p (one-tailed) = 0.13). Subjective measures of fatigue increased significantly from early to late reading. To date, the results support our findings with static images and detection of bone fractures. Radiologists at the end of a long work day experience greater levels of measurable visual fatigue or strain, contributing to a decrease in diagnostic accuracy. The decrease in accuracy was not as great however as with static images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Bin, E-mail: bins@ieee.org
2014-07-01
We describe an algorithm that can adaptively provide mixture summaries of multimodal posterior distributions. The parameter space of the involved posteriors ranges in size from a few dimensions to dozens of dimensions. This work was motivated by an astrophysical problem called extrasolar planet (exoplanet) detection, wherein the computation of stochastic integrals that are required for Bayesian model comparison is challenging. The difficulty comes from the highly nonlinear models that lead to multimodal posterior distributions. We resort to importance sampling (IS) to estimate the integrals, and thus translate the problem to be how to find a parametric approximation of the posterior.more » To capture the multimodal structure in the posterior, we initialize a mixture proposal distribution and then tailor its parameters elaborately to make it resemble the posterior to the greatest extent possible. We use the effective sample size (ESS) calculated based on the IS draws to measure the degree of approximation. The bigger the ESS is, the better the proposal resembles the posterior. A difficulty within this tailoring operation lies in the adjustment of the number of mixing components in the mixture proposal. Brute force methods just preset it as a large constant, which leads to an increase in the required computational resources. We provide an iterative delete/merge/add process, which works in tandem with an expectation-maximization step to tailor such a number online. The efficiency of our proposed method is tested via both simulation studies and real exoplanet data analysis.« less
Estimate of the neutron fields in ATLAS based on ATLAS-MPX detectors data
NASA Astrophysics Data System (ADS)
Bouchami, J.; Dallaire, F.; Gutiérrez, A.; Idarraga, J.; Král, V.; Leroy, C.; Picard, S.; Pospíšil, S.; Scallon, O.; Solc, J.; Suk, M.; Turecek, D.; Vykydal, Z.; Žemlièka, J.
2011-01-01
The ATLAS-MPX detectors are based on Medipix2 silicon devices designed by CERN for the detection of different types of radiation. These detectors are covered with converting layers of 6LiF and polyethylene (PE) to increase their sensitivity to thermal and fast neutrons, respectively. These devices allow the measurement of the composition and spectroscopic characteristics of the radiation field in ATLAS, particularly of neutrons. These detectors can operate in low or high preset energy threshold mode. The signature of particles interacting in a ATLAS-MPX detector at low threshold are clusters of adjacent pixels with different size and form depending on their type, energy and incidence angle. The classification of particles into different categories can be done using the geometrical parameters of these clusters. The Medipix analysis framework (MAFalda) — based on the ROOT application — allows the recognition of particle tracks left in ATLAS-MPX devices located at various positions in the ATLAS detector and cavern. The pattern recognition obtained from the application of MAFalda was configured to distinguish the response of neutrons from other radiation. The neutron response at low threshold is characterized by clusters of adjoining pixels (heavy tracks and heavy blobs) left by protons and heavy ions resulting from neutron interactions in the converting layers of the ATLAS-MPX devices. The neutron detection efficiency of ATLAS-MPX devices has been determined by the exposure of two detectors of reference to radionuclide sources of neutrons (252Cf and 241AmBe). With these results, an estimate of the neutrons fields produced at the devices locations during ATLAS operation was done.
Su, Zhong; Zhang, Lisha; Ramakrishnan, V.; Hagan, Michael; Anscher, Mitchell
2011-01-01
Purpose: To evaluate both the Calypso Systems’ (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal–oxide–semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters’ reading accuracy in the presence of wireless electromagnetic transponders inside a phantom.Methods: A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with∕without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with∕without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit.Results: Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0.5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%.Conclusions: The phantom study indicated that the Calypso System’s localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems. PMID:21776780
High sensitivity detection of trace gases at atmospheric pressure using tunable diode lasers
NASA Technical Reports Server (NTRS)
Reid, J.; Sinclair, R. L.; Grant, W. B.; Menzies, R. T.
1985-01-01
A detailed study of the detection of trace gases at atmospheric pressure using tunable diode lasers is described. The influence of multipass cells, retroreflectors and topographical targets is examined. The minimum detectable infrared absorption ranges from 0.1 percent for a pathlength of 1.2 km to 0.01 percent over short pathlengths. The factors which limit this sensitivity are discussed, and the techniques are illustrated by monitoring atmospehric CO2 and CH4.
DETECTION OF KOI-13.01 USING THE PHOTOMETRIC ORBIT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shporer, Avi; Jenkins, Jon M.; Seader, Shawn E.
2011-12-15
We use the KOI-13 transiting star-planet system as a test case for the recently developed BEER algorithm, aimed at identifying non-transiting low-mass companions by detecting the photometric variability induced by the companion along its orbit. Such photometric variability is generated by three mechanisms: the beaming effect, tidal ellipsoidal distortion, and reflection/heating. We use data from three Kepler quarters, from the first year of the mission, while ignoring measurements within the transit and occultation, and show that the planet's ephemeris is clearly detected. We fit for the amplitude of each of the three effects and use the beaming effect amplitude tomore » estimate the planet's minimum mass, which results in M{sub p} sin i = 9.2 {+-} 1.1 M{sub J} (assuming the host star parameters derived by Szabo et al.). Our results show that non-transiting star-planet systems similar to KOI-13.01 can be detected in Kepler data, including a measurement of the orbital ephemeris and the planet's minimum mass. Moreover, we derive a realistic estimate of the amplitudes uncertainties, and use it to show that data obtained during the entire lifetime of the Kepler mission of 3.5 years will allow detecting non-transiting close-in low-mass companions orbiting bright stars, down to the few Jupiter mass level. Data from the Kepler Extended Mission, if funded by NASA, will further improve the detection capabilities.« less
Turbofan engine demonstration of sensor failure detection
NASA Technical Reports Server (NTRS)
Merrill, Walter C.; Delaat, John C.; Abdelwahab, Mahmood
1991-01-01
In the paper, the results of a full-scale engine demonstration of a sensor failure detection algorithm are presented. The algorithm detects, isolates, and accommodates sensor failures using analytical redundancy. The experimental hardware, including the F100 engine, is described. Demonstration results were obtained over a large portion of a typical flight envelope for the F100 engine. They include both subsonic and supersonic conditions at both medium and full, nonafter burning, power. Estimated accuracy, minimum detectable levels of sensor failures, and failure accommodation performance for an F100 turbofan engine control system are discussed.
Kelly, Brian P.; Rydlund, Jr., Paul H.
2006-01-01
Riverbank filtration substantially improves the source-water quality of the Independence, Missouri well field. Coliform bacteria, Cryptosporidium, Giardia, viruses and selected constituents were analyzed in water samples from the Missouri River, two vertical wells, and a collector well. Total coliform bacteria, Cryptosporidium, Giardia, and total culturable viruses were detected in the Missouri River, but were undetected in samples from wells. Using minimum reporting levels for non-detections in well samples, minimum log removals were 4.57 for total coliform bacteria, 1.67 for Cryptosporidium, 1.67 for Giardia, and 1.15 for total culturable virus. Ground-water flow rates between the Missouri River and wells were calculated from water temperature profiles and ranged between 1.2 and 6.7 feet per day. Log removals based on sample pairs separated by the traveltime between the Missouri River and wells were infinite for total coliform bacteria (minimum detection level equal to zero), between 0.8 and 3.5 for turbidity, between 1.5 and 2.1 for Giardia, and between 0.4 and 2.6 for total culturable viruses. Cryptosporidium was detected once in the Missouri River but no corresponding well samples were available. No clear relation was evident between changes in water quality in the Missouri River and in wells for almost all constituents. Results of analyses for organic wastewater compounds and the distribution of dissolved oxygen, specific conductance, and temperature in the Missouri River indicate water quality on the south side of the river was moderately influenced by the south bank inflows to the river upstream from the Independence well field.
UNUSUAL TRENDS IN SOLAR P-MODE FREQUENCIES DURING THE CURRENT EXTENDED MINIMUM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tripathy, S. C.; Jain, K.; Hill, F.
2010-03-10
We investigate the behavior of the intermediate-degree mode frequencies of the Sun during the current extended minimum phase to explore the time-varying conditions in the solar interior. Using contemporaneous helioseismic data from the Global Oscillation Network Group (GONG) and the Michelson Doppler Imager (MDI), we find that the changes in resonant mode frequencies during the activity minimum period are significantly greater than the changes in solar activity as measured by different proxies. We detect a seismic minimum in MDI p-mode frequency shifts during 2008 July-August but no such signature is seen in mean shifts computed from GONG frequencies. We alsomore » analyze the frequencies of individual oscillation modes from GONG data as a function of latitude and observe a signature of the onset of the solar cycle 24 in early 2009. Thus, the intermediate-degree modes do not confirm the onset of the cycle 24 during late 2007 as reported from the analysis of the low-degree Global Oscillations at Low Frequency frequencies. Further, both the GONG and MDI frequencies show a surprising anti-correlation between frequencies and activity proxies during the current minimum, in contrast to the behavior during the minimum between cycles 22 and 23.« less
Sensitive detection of formaldehyde using an interband cascade laser near 3.6 μm
Ren, Wei; Luo, Longqiang; Tittel, Frank K.
2015-12-31
Here, we report the development of a formaldehyde (H 2CO) trace gas sensor using a continuous wave (CW), thermoelectrically-cooled (TEC), distributed-feedback interband cascade laser (DFB-ICL) at 3.6 μm. Wavelength modulation spectroscopy was used to detect the second harmonic spectra of a strong H 2CO absorption feature centered at 2778.5 cm -1 (3599 nm) in its ν 1 fundamental vibrational band. A compact and novel multipass cell (7.6-cm physical length and 32-ml sampling volume) was implemented to achieve an effective optical path length of 3.75 m. A minimum detection limit of 6 parts per billion (ppb) at an optimum gas pressuremore » of 200 Torr was achieved with a 1-s data acquisition time. An Allan-Werle deviation analysis was performed to investigate the long-term stability of the sensor system and a 1.5 ppb minimum detectable concentration could be achieved by averaging up to 140 s. Absorption interference eeffects from atmospheric H 2O (2%) and CH 4(5 ppm) were also analyzed in this work and proved to be insignificant for the current sensor configuration.« less
Sensitive detection of formaldehyde using an interband cascade laser near 3.6 μm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Wei; Luo, Longqiang; Tittel, Frank K.
Here, we report the development of a formaldehyde (H 2CO) trace gas sensor using a continuous wave (CW), thermoelectrically-cooled (TEC), distributed-feedback interband cascade laser (DFB-ICL) at 3.6 μm. Wavelength modulation spectroscopy was used to detect the second harmonic spectra of a strong H 2CO absorption feature centered at 2778.5 cm -1 (3599 nm) in its ν 1 fundamental vibrational band. A compact and novel multipass cell (7.6-cm physical length and 32-ml sampling volume) was implemented to achieve an effective optical path length of 3.75 m. A minimum detection limit of 6 parts per billion (ppb) at an optimum gas pressuremore » of 200 Torr was achieved with a 1-s data acquisition time. An Allan-Werle deviation analysis was performed to investigate the long-term stability of the sensor system and a 1.5 ppb minimum detectable concentration could be achieved by averaging up to 140 s. Absorption interference eeffects from atmospheric H 2O (2%) and CH 4(5 ppm) were also analyzed in this work and proved to be insignificant for the current sensor configuration.« less
Herrera, Melina E; Mobilia, Liliana N; Posse, Graciela R
2011-01-01
The objective of this study is to perform a comparative evaluation of the prediffusion and minimum inhibitory concentration (MIC) methods for the detection of sensitivity to colistin, and to detect Acinetobacter baumanii-calcoaceticus complex (ABC) heteroresistant isolates to colistin. We studied 75 isolates of ABC recovered from clinically significant samples obtained from various centers. Sensitivity to colistin was determined by prediffusion as well as by MIC. All the isolates were sensitive to colistin, with MIC = 2µg/ml. The results were analyzed by dispersion graph and linear regression analysis, revealing that the prediffusion method did not correlate with the MIC values for isolates sensitive to colistin (r² = 0.2017). Detection of heteroresistance to colistin was determined by plaque efficiency of all the isolates with the same initial MICs of 2, 1, and 0.5 µg/ml, which resulted in 14 of them with a greater than 8-fold increase in the MIC in some cases. When the sensitivity of these resistant colonies was determined by prediffusion, the resulting dispersion graph and linear regression analysis yielded an r² = 0.604, which revealed a correlation between the methodologies used.
Li, Chuanliang; Wu, Yingfa; Qiu, Xuanbing; Wei, Jilin; Deng, Lunhua
2017-05-01
Wavelength modulation spectroscopy (WMS) combined with a multipass absorption cell has been used to measure a weak absorption line of carbon monoxide (CO) at 1.578 µm. A 0.95m Herriott-type cell provides an effective absorption path length of 55.1 m. The WMS signals from the first and second harmonic output of a lock-in amplifier (WMS-1 f and 2 f, respectively) agree with the Beer-Lambert law, especially at low concentrations. After boxcar averaging, the minimum detection limit achieved is 4.3 ppm for a measurement time of 0.125 s. The corresponding normalized detection limit is 84 ppm m Hz -1/2 . If the integrated time is increased to 88 s, the minimum detectable limit of CO can reach to 0.29 ppm based on an Allan variation analysis. The pressure-dependent relationship is validated after accounting for the pressure factor in data processing. Finally, a linear correlation between the WMS-2 f amplitudes and gas concentrations is obtained at concentration ratios less than 15.5%, and the accuracy is better than 92% at total pressure less than 62.7 Torr.
Optimal sensor placement for active guided wave interrogation of complex metallic components
NASA Astrophysics Data System (ADS)
Coelho, Clyde K.; Kim, Seung Bum; Chattopadhyay, Aditi
2011-04-01
With research in structural health monitoring (SHM) moving towards increasingly complex structures for damage interrogation, the placement of sensors is becoming a key issue in the performance of the damage detection methodologies. For ultrasonic wave based approaches, this is especially important because of the sensitivity of the travelling Lamb waves to material properties, geometry and boundary conditions that may obscure the presence of damage if they are not taken into account during sensor placement. The framework proposed in this paper defines a sensing region for a pair of piezoelectric transducers in a pitch-catch damage detection approach by taking into account the material attenuation and probability of false alarm. Using information about the region interrogated by a sensoractuator pair, a simulated annealing optimization framework was implemented in order to place sensors on complex metallic geometries such that a selected minimum damage type and size could be detected with an acceptable probability of false alarm anywhere on the structure. This approach was demonstrated on a lug joint to detect a crack and on a large Naval SHM test bed and resulted in a placement of sensors that was able to interrogate all parts of the structure using the minimum number of transducers.
Determination of vigabatrin in plasma by reversed-phase high-performance liquid chromatography.
Tsanaclis, L M; Wicks, J; Williams, J; Richens, A
1991-05-01
A method is described for the determination of vigabatrin in 50 microliters of plasma by isocratic high-performance liquid chromatography using fluorescence detection. The procedure involves protein precipitation with methanol followed by precolumn derivatisation with o-phthaldialdehyde reagent. Separation of the derivatised vigabatrin was achieved on a Microsorb C18 column using a mobile phase of 10 mM orthophosphoric acid:acetonitrile:methanol (6:3:1) at a flow rate of 2.0 ml/min. Assay time is 15 min and chromatograms show no interference from commonly coadministered anticonvulsant drugs. The total analytical error within the range of 0.85-85 micrograms/ml was found to be 7.6% with the within-replicates error of 2.76%. The minimum detection limit was 0.08 micrograms/ml and the minimum quantitation limit was 0.54 micrograms/ml.
NASA Technical Reports Server (NTRS)
Ghatas, Rania W.; Jack, Devin P.; Tsakpinis, Dimitrios; Sturdy, James L.; Vincent, Michael J.; Hoffler, Keith D.; Myer, Robert R.; DeHaven, Anna M.
2017-01-01
As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The technique, results, and lessons learned from a detailed End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS), based on specific test vectors and encounter cases, will be presented in this paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loomis, Ryan A.; McGuire, Brett A.; Remijan, Anthony J.
Recently, Lattelais et al. have interpreted aggregated observations of molecular isomers to suggest that there exists a ''minimum energy principle'', such that molecular formation will favor more stable molecular isomers for thermodynamic reasons. To test the predictive power of this principle, we have fully characterized the spectra of the three isomers of C{sub 3}H{sub 2}O toward the well-known molecular region Sgr B2(N). Evidence for the detection of the isomers cyclopropenone (c-C{sub 3}H{sub 2}O) and propynal (HCCCHO) is presented, along with evidence for the non-detection of the lowest zero-point energy isomer, propadienone (CH{sub 2}CCO). We interpret these observations as evidence that chemicalmore » formation pathways, which may be under kinetic control, have a more pronounced effect on final isomer abundances than thermodynamic effects such as the minimum energy principle.« less
The Impact of a City-Level Minimum-Wage Policy on Supermarket Food Prices in Seattle-King County
Tang, Wesley; Aggarwal, Anju; Vigdor, Jacob; Drewnowski, Adam
2017-01-01
Background: Many states and localities throughout the U.S. have adopted higher minimum wages. Higher labor costs among low-wage food system workers could result in higher food prices. Methods: Using a market basket of 106 foods, food prices were collected at affected chain supermarket stores in Seattle and same-chain unaffected stores in King County (n = 12 total, six per location). Prices were collected at 1 month pre- (March 2015) and 1-month post-policy enactment (May 2015), then again 1-year post-policy enactment (May 2016). Unpaired t-tests were used to detect price differences by location at fixed time while paired t-tests were used to detect price difference across time with fixed store chain. A multi-level, linear differences-in-differences model, was used to detect the changes in the average market basket item food prices over time across regions, overall and by food group. Results: There were no significant differences in overall market basket or item-level costs at one-month (−$0.01, SE = 0.05, p = 0.884) or one-year post-policy enactment (−$0.02, SE = 0.08, p = 0.772). No significant increases were observed by food group. Conclusions: There is no evidence of change in supermarket food prices by market basket or increase in prices by food group in response to the implementation of Seattle’s minimum wage ordinance. PMID:28891937
NASA Astrophysics Data System (ADS)
Suhaila, Jamaludin; Yusop, Zulkifli
2017-06-01
Most of the trend analysis that has been conducted has not considered the existence of a change point in the time series analysis. If these occurred, then the trend analysis will not be able to detect an obvious increasing or decreasing trend over certain parts of the time series. Furthermore, the lack of discussion on the possible factors that influenced either the decreasing or the increasing trend in the series needs to be addressed in any trend analysis. Hence, this study proposes to investigate the trends, and change point detection of mean, maximum and minimum temperature series, both annually and seasonally in Peninsular Malaysia and determine the possible factors that could contribute to the significance trends. In this study, Pettitt and sequential Mann-Kendall (SQ-MK) tests were used to examine the occurrence of any abrupt climate changes in the independent series. The analyses of the abrupt changes in temperature series suggested that most of the change points in Peninsular Malaysia were detected during the years 1996, 1997 and 1998. These detection points captured by Pettitt and SQ-MK tests are possibly related to climatic factors, such as El Niño and La Niña events. The findings also showed that the majority of the significant change points that exist in the series are related to the significant trend of the stations. Significant increasing trends of annual and seasonal mean, maximum and minimum temperatures in Peninsular Malaysia were found with a range of 2-5 °C/100 years during the last 32 years. It was observed that the magnitudes of the increasing trend in minimum temperatures were larger than the maximum temperatures for most of the studied stations, particularly at the urban stations. These increases are suspected to be linked with the effect of urban heat island other than El Niño event.
Trend analysis of long-term temperature time series in the Greater Toronto Area (GTA)
NASA Astrophysics Data System (ADS)
Mohsin, Tanzina; Gough, William A.
2010-08-01
As the majority of the world’s population is living in urban environments, there is growing interest in studying local urban climates. In this paper, for the first time, the long-term trends (31-162 years) of temperature change have been analyzed for the Greater Toronto Area (GTA). Annual and seasonal time series for a number of urban, suburban, and rural weather stations are considered. Non-parametric statistical techniques such as Mann-Kendall test and Theil-Sen slope estimation are used primarily for the assessing of the significance and detection of trends, and the sequential Mann test is used to detect any abrupt climate change. Statistically significant trends for annual mean and minimum temperatures are detected for almost all stations in the GTA. Winter is found to be the most coherent season contributing substantially to the increase in annual minimum temperature. The analyses of the abrupt changes in temperature suggest that the beginning of the increasing trend in Toronto started after the 1920s and then continued to increase to the 1960s. For all stations, there is a significant increase of annual and seasonal (particularly winter) temperatures after the 1980s. In terms of the linkage between urbanization and spatiotemporal thermal patterns, significant linear trends in annual mean and minimum temperature are detected for the period of 1878-1978 for the urban station, Toronto, while for the rural counterparts, the trends are not significant. Also, for all stations in the GTA that are situated in all directions except south of Toronto, substantial temperature change is detected for the periods of 1970-2000 and 1989-2000. It is concluded that the urbanization in the GTA has significantly contributed to the increase of the annual mean temperatures during the past three decades. In addition to urbanization, the influence of local climate, topography, and larger scale warming are incorporated in the analysis of the trends.
Natural gas pipeline leak detector based on NIR diode laser absorption spectroscopy.
Gao, Xiaoming; Fan, Hong; Huang, Teng; Wang, Xia; Bao, Jian; Li, Xiaoyun; Huang, Wei; Zhang, Weijun
2006-09-01
The paper reports on the development of an integrated natural gas pipeline leak detector based on diode laser absorption spectroscopy. The detector transmits a 1.653 microm DFB diode laser with 10 mW and detects a fraction of the backscatter reflected from the topographic targets. To eliminate the effect of topographic scatter targets, a ratio detection technique was used. Wavelength modulation and harmonic detection were used to improve the detection sensitivity. The experimental detection limit is 50 ppmm, remote detection for a distance up to 20 m away topographic scatter target is demonstrated. Using a known simulative leak pipe, minimum detectable pipe leak flux is less than 10 ml/min.
Davis, Joe M
2011-10-28
General equations are derived for the distribution of minimum resolution between two chromatographic peaks, when peak heights in a multi-component chromatogram follow a continuous statistical distribution. The derivation draws on published theory by relating the area under the distribution of minimum resolution to the area under the distribution of the ratio of peak heights, which in turn is derived from the peak-height distribution. Two procedures are proposed for the equations' numerical solution. The procedures are applied to the log-normal distribution, which recently was reported to describe the distribution of component concentrations in three complex natural mixtures. For published statistical parameters of these mixtures, the distribution of minimum resolution is similar to that for the commonly assumed exponential distribution of peak heights used in statistical-overlap theory. However, these two distributions of minimum resolution can differ markedly, depending on the scale parameter of the log-normal distribution. Theory for the computation of the distribution of minimum resolution is extended to other cases of interest. With the log-normal distribution of peak heights as an example, the distribution of minimum resolution is computed when small peaks are lost due to noise or detection limits, and when the height of at least one peak is less than an upper limit. The distribution of minimum resolution shifts slightly to lower resolution values in the first case and to markedly larger resolution values in the second one. The theory and numerical procedure are confirmed by Monte Carlo simulation. Copyright © 2011 Elsevier B.V. All rights reserved.
Wu, Ye; Li, Xiaoming; Wei, Yi; Gu, Yu; Zeng, Haibo
2017-12-21
Photo-communication has attracted great attention because of the rapid development of wireless information transmission technology. However, it is still a great challenge in cryptography communications, where it is greatly weakened by the openness of the light channels. Here, visible-infrared dual-mode narrowband perovskite photodetectors were fabricated and a new photo-communication encryption technique was proposed. For the first time, highly narrowband and two-photon absorption (TPA) resultant photoresponses within a single photodetector are demonstrated. The full width at half maximum (FWHM) of the photoresponse is as narrow as 13.6 nm in the visible range, which is superior to state-of-the-art narrowband photodetectors. Furthermore, these two merits of narrowband and TPA characteristics are utilized to encrypt the photo-communication based on the above photodetectors. When sending information and noise signals with 532 and 442 nm laser light simultaneously, the perovskite photodetectors only receive the main information, while the commercial Si photodetector responds to both lights, losing the main information completely. The final data are determined by the secret key through the TPA process as preset. Such narrowband and TPA detection abilities endow the perovskite photodetectors with great potential in future security communication and also provide new opportunities and platforms for encryption techniques.
Wonnemann, Meinolf; Frömke, Cornelia; Koch, Armin
2015-01-01
We investigated different evaluation strategies for bioequivalence trials with highly variable drugs on their resulting empirical type I error and empirical power. The classical 'unscaled' crossover design with average bioequivalence evaluation, the Add-on concept of the Japanese guideline, and the current 'scaling' approach of EMA were compared. Simulation studies were performed based on the assumption of a single dose drug administration while changing the underlying intra-individual variability. Inclusion of Add-on subjects following the Japanese concept led to slight increases of the empirical α-error (≈7.5%). For the approach of EMA we noted an unexpected tremendous increase of the rejection rate at a geometric mean ratio of 1.25. Moreover, we detected error rates slightly above the pre-set limit of 5% even at the proposed 'scaled' bioequivalence limits. With the classical 'unscaled' approach and the Japanese guideline concept the goal of reduced subject numbers in bioequivalence trials of HVDs cannot be achieved. On the other hand, widening the acceptance range comes at the price that quite a number of products will be accepted bioequivalent that had not been accepted in the past. A two-stage design with control of the global α therefore seems the better alternative.
Design of a microbial contamination detector and analysis of error sources in its optical path.
Zhang, Chao; Yu, Xiang; Liu, Xingju; Zhang, Lei
2014-05-01
Microbial contamination is a growing concern in the food safety today. To effectively control the types and degree of microbial contamination during food production, this paper introduces a design for a microbial contamination detector that can be used for quick in-situ examination. The designed detector can identify the category of microbial contamination by locating its characteristic absorption peak and then can calculate the concentration of the microbial contamination by fitting the absorbance vs. concentration lines of standard samples with gradient concentrations. Based on traditional scanning grating detection system, this design improves the light splitting unit to expand the scanning range and enhance the accuracy of output wavelength. The motor rotation angle φ is designed to have a linear relationship with the output wavelength angle λ, which simplifies the conversion of output spectral curves into wavelength vs. light intensity curves. In this study, we also derive the relationship between the device's major sources of errors and cumulative error of the output wavelengths, and suggest a simple correction for these errors. The proposed design was applied to test pigments and volatile basic nitrogen (VBN) which evaluated microbial contamination degrees of meats, and the deviations between the measured values and the pre-set values were only in a low range of 1.15% - 1.27%.
High voltage plasma sheath analysis related to TSS-1
NASA Technical Reports Server (NTRS)
Sheldon, John W.
1990-01-01
On the first mission of the Tethered Satellite System (TSS-1), a 1.8 m diameter spherical satellite will be deployed a distance of 20 km above the Space Shuttle Orbiter on an insulated conducting tether. The satellite will be held at electric potentials up to 5000 volts positive with respect to the ambient plasma. Due to the passage of the conducting tether through the Earth's magnetic field, an electromagnetic field (EMF) will be created, driving electrons down the tether to the Orbiter, out through an electron gun into the ionosphere and back into the positive-biased satellite. The main problem addressed here is the current-voltage characteristics of the ionospheric interaction with the satellite. The first problem is that while the satellite will be capable of measuring charged particle flow to the surface at several locations, the detectors have a limited range of acceptance angle. The second problem is that the angle of incidence of the incoming electrons will have to be relative to the local normal. This will be important in order to predict the magnitude of the detectable current at each detector location so the detector gain can be pre-set to the correct range. The plasma sheath was analyzed mathematically, and subroutines were written to solve relevant finite element, Taylor-Vlasov, and Poisson equations.
Li, Kui; Wang, Lei; Lv, Yanhong; Gao, Pengyu; Song, Tianxiao
2015-01-01
Getting a land vehicle’s accurate position, azimuth and attitude rapidly is significant for vehicle based weapons’ combat effectiveness. In this paper, a new approach to acquire vehicle’s accurate position and orientation is proposed. It uses biaxial optical detection platform (BODP) to aim at and lock in no less than three pre-set cooperative targets, whose accurate positions are measured beforehand. Then, it calculates the vehicle’s accurate position, azimuth and attitudes by the rough position and orientation provided by vehicle based navigation systems and no less than three couples of azimuth and pitch angles measured by BODP. The proposed approach does not depend on Global Navigation Satellite System (GNSS), thus it is autonomous and difficult to interfere. Meanwhile, it only needs a rough position and orientation as algorithm’s iterative initial value, consequently, it does not have high performance requirement for Inertial Navigation System (INS), odometer and other vehicle based navigation systems, even in high precise applications. This paper described the system’s working procedure, presented theoretical deviation of the algorithm, and then verified its effectiveness through simulation and vehicle experiments. The simulation and experimental results indicate that the proposed approach can achieve positioning and orientation accuracy of 0.2 m and 20″ respectively in less than 3 min. PMID:26492249
Gastrocnemius tightness on joint angle and work of lower extremity during gait.
You, Jia-Yuan; Lee, Hsin-Min; Luo, Hong-Ji; Leu, Chwan-Chin; Cheng, Pen-Gang; Wu, Shyi-Kuen
2009-11-01
Muscular tightness is a common clinical musculoskeletal disorder and is regarded as a predisposing factor for muscle injuries. In this study, a two-way mixed design ANOVA was applied to investigate the effects of the gastrocnemius tightness on the joint angle and joint work during walking. Twenty-two patients with muscular tightness of gastrocnemius muscle (<12 degrees of ankle dorsiflexion with knee extended) and 22 age- and gender-matched subjects with normal gastrocnemius flexibility (>15 degrees of ankle dorsiflexion with knee extended) participated in this study. The joint angle and work at hip, knee, and ankle joints during the stance phase were analyzed at two preset cadences of 100 steps/min and 140 steps/min. Significantly greater flexion angles at hip (P=0.025) and knee (P=0.001) were found in the tightness group at the time of maximal ankle dorsiflexion. Significantly less work generation at knee (P=0.034) and greater work absorption at ankle (P=0.024) were detected in the tightness group. The subjects with gastrocnemius tightness revealed a compensatory gait pattern, which included the changes in the joint angles and associated work productions. The potential disturbance of the knee control and strain injuries of plantar flexors might be crucial in the clinical considerations for subjects with gastrocnemius tightness.
Li, Kui; Wang, Lei; Lv, Yanhong; Gao, Pengyu; Song, Tianxiao
2015-10-20
Getting a land vehicle's accurate position, azimuth and attitude rapidly is significant for vehicle based weapons' combat effectiveness. In this paper, a new approach to acquire vehicle's accurate position and orientation is proposed. It uses biaxial optical detection platform (BODP) to aim at and lock in no less than three pre-set cooperative targets, whose accurate positions are measured beforehand. Then, it calculates the vehicle's accurate position, azimuth and attitudes by the rough position and orientation provided by vehicle based navigation systems and no less than three couples of azimuth and pitch angles measured by BODP. The proposed approach does not depend on Global Navigation Satellite System (GNSS), thus it is autonomous and difficult to interfere. Meanwhile, it only needs a rough position and orientation as algorithm's iterative initial value, consequently, it does not have high performance requirement for Inertial Navigation System (INS), odometer and other vehicle based navigation systems, even in high precise applications. This paper described the system's working procedure, presented theoretical deviation of the algorithm, and then verified its effectiveness through simulation and vehicle experiments. The simulation and experimental results indicate that the proposed approach can achieve positioning and orientation accuracy of 0.2 m and 20″ respectively in less than 3 min.
NASA Astrophysics Data System (ADS)
Clifton, K. S.; Owens, J. K.
1983-04-01
Efforts continue regarding the analysis of particulate contamination recorded by the Camera/Photometers on STS-2. These systems were constructed by Epsilon Laboratories, Inc. and consisted of two 16-mm photographic cameras, using Kodak Double X film, Type 7222, to make stereoscopic observations of contaminant particles and background. Each was housed within a pressurized canister and operated automatically throughout the mission, making simultaneous exposures on a continuous basis every 150 sec. The cameras were equipped with 18-mm f/0.9 lenses and subtended overlapping 20° fields-of-view. An integrating photometer was used to inhibit the exposure sequences during periods of excessive illumination and to terminate the exposures at preset light levels. During the exposures, a camera shutter operated in a chopping mode in order to isolate the movement of particles for velocity determinations. Calculations based on the preflight film calibration indicate that particles as small as 25 μm can be detected from ideal observing conditions. Current emphasis is placed on the digitization of the photographic data frames and the determination of particle distances, sizes, and velocities. It has been concluded that background bright-ness measurements cannot be established with any reliability on the STS-2 mission, due to the preponderance of Earth-directed attitudes and the incidence of light reflected from nearby surfaces.
1992-05-31
Samples were preserved (27) stemmed from a loss in titer that occurred when viruses in 1% glutaraldehyde before application to carbon-coated were added to...counting a minimum of 100 VLPs from 5 random fields at a magnification of 10,000 x. For most applications counting a minimum of 20 fields containing at...biological applications , Vol. 4, Hayat, M.A., editor, Van Nostrom Reinhold, N.Y., 1974, pp 79-104. 15. Proctor, L.M., and Fuhrman, J.A., Viral mortality
1992-05-22
Frobenius Theory : Why Hilberts Metric ?," Mathematics of Operations Research 7 (1982) pp.198-210. 11. H. S. M. Cnxeter, Regular Complex Poly- topes...can be made to perform logic functions by pre-setting the device to a given state. We can, in theory , achieve arbitrary logical functionality by using...then extrapolating on the basis of this theory , is about 2000 two diffracted spots appear in the focal plane of the channels. output lenslet array
GenIce: Hydrogen-Disordered Ice Generator.
Matsumoto, Masakazu; Yagasaki, Takuma; Tanaka, Hideki
2018-01-05
GenIce is an efficient and user-friendly tool to generate hydrogen-disordered ice structures. It makes ice and clathrate hydrate structures in various file formats. More than 100 kinds of structures are preset. Users can install their own crystal structures, guest molecules, and file formats as plugins. The algorithm certifies that the generated structures are completely randomized hydrogen-disordered networks obeying the ice rule with zero net polarization. © 2017 The Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc. © 2017 The Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc.
Design and Specification of Low Pressure Sewer Systems for Recreation Areas.
1985-02-01
holding tank receives wastewater Iflows by gravity. Level scitsors act ivate the grinder pump operation pump at preset levels. Emergency 40 overf low aid...above the septic 0 Lank floor, the septic tank should be secured against flotation . Test in. 70. Septir t.ank s shouldt Ihe wat’rtight and must be...8217 , pump i rig je,j , aind powt, r cost . Annual power cost can he estimated using the fo I I owi rig express ion: APC =ae PC (4) whe -e 0 APIC annual
STS-96 crew plays cards in the Node 1/Unity module
2017-04-20
S96-E-5173 (2 June 1999) --- A pre-set electronic still camera (ESC) recorded this image of the STS-96 crewmembers playing cards on a break aboard the International Space Station (ISS). From the left are cosmonaut Valery I. Tokarev, Daniel T. Barry, Tamara E. Jernigan, Rick D. Husband, Ellen Ochoa, Julie Payette and Kent V. Rominger. Tokarev represents the Russian Space Agency (RSA) and Payette represents the Canadian Space Agency (CSA). The photograph was taken at 11:13:59 GMT, June 2, 1999.
Adaptive Sampling using Support Vector Machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. Mandelli; C. Smith
2012-11-01
Reliability/safety analysis of stochastic dynamic systems (e.g., nuclear power plants, airplanes, chemical plants) is currently performed through a combination of Event-Tress and Fault-Trees. However, these conventional methods suffer from certain drawbacks: • Timing of events is not explicitly modeled • Ordering of events is preset by the analyst • The modeling of complex accident scenarios is driven by expert-judgment For these reasons, there is currently an increasing interest into the development of dynamic PRA methodologies since they can be used to address the deficiencies of conventional methods listed above.
Spinal cord testing: auditing for quality assurance.
Marr, J A; Reid, B
1991-04-01
A quality assurance audit of spinal cord testing as documented by staff nurses was carried out. Twenty-five patient records were examined for accuracy of documented testing and compared to assessments performed by three investigators. A pilot study established interrater reliability of a tool that was designed especially for this study. Results indicated staff nurses failed to meet pre-established 100% standard in all categories of testing when compared with investigator's findings. Possible reasons for this disparity are discussed as well as indications for modifications in the spinal testing record, teaching program and preset standards.
A method for monitoring the variability in nuclear absorption characteristics of aviation fuels
NASA Technical Reports Server (NTRS)
Sprinkle, Danny R.; Shen, Chih-Ping
1988-01-01
A technique for monitoring variability in the nuclear absorption characteristics of aviation fuels has been developed. It is based on a highly collimated low energy gamma radiation source and a sodium iodide counter. The source and the counter assembly are separated by a geometrically well-defined test fuel cell. A computer program for determining the mass attenuation coefficient of the test fuel sample, based on the data acquired for a preset counting period, has been developed and tested on several types of aviation fuel.
Safety and performance enhancement circuit for primary explosive detonators
Davis, Ronald W [Tracy, CA
2006-04-04
A safety and performance enhancement arrangement for primary explosive detonators. This arrangement involves a circuit containing an energy storage capacitor and preset self-trigger to protect the primary explosive detonator from electrostatic discharge (ESD). The circuit does not discharge into the detonator until a sufficient level of charge is acquired on the capacitor. The circuit parameters are designed so that normal ESD environments cannot charge the protection circuit to a level to achieve discharge. When functioned, the performance of the detonator is also improved because of the close coupling of the stored energy.
DeShong, J.A.
1960-03-01
A control-limiting device for monltoring a control system is described. The system comprises a conditionsensing device, a condition-varying device exerting a control over the condition, and a control means to actuate the condition-varying device. A control-limiting device integrates the total movement or other change of the condition-varying device over any interval of time during a continuum of overlapping periods of time, and if the tothl movement or change of the condition-varying device exceeds a preset value, the control- limiting device will switch the control of the operated apparatus from automatic to manual control.
Investigation of Altitude Starting and Acceleration Characteristics of J47 Turbojet Engine
NASA Technical Reports Server (NTRS)
Golladay, Richard L; Bloomer, Harry E
1951-01-01
An investigation was conducted on an axial-flow-compressor type turbojet engine in the NACA Lewis altitude wind tunnel to determine the operational characteristics of several ignition systems, cross-fire tube configurations and fuel systems over a range of simulated flight conditions. The opposite-polarity-type spark plug provided the most satisfactory ignition. Increasing the cross-fire-tube diameter improved intercombustor flame propagation. At high windmilling speeds, accelerations to approximately 6200 rpm could be made at a preset constant throttle position. The use of a variable-area nozzle reduced acceleration time.
The Timer-Logger-Communicator for Continuous, Mobile Measurement of Wheelchair Pressure Reliefs
Grip, Jeffrey C.; Merbitz, Charles T.
1985-01-01
A recently developed device which provides continuous, direct monitoring of the pressure-relief performance of persons confined to wheelchairs is reported. A custom portable computer records the data, which is transferred for analysis to an Apple IIe. The mobile computer can also signal the patient to relieve pressure based on preset criteria and the patient's performance. Teaching lift-offs to prevent ischial pressure sores is the object. Data collected with the device are used clinically and for research. Examples of such data are presented. The benefits of the device are reviewed.
Expedition One and STS-97 crew pose for portrait
2000-12-08
S97-E-5144 (8 December 2000) --- The STS-97 astronauts and the Expedition 1 crew members pose for an historic portrait onboard the International Space Station (ISS) shortly after hatches were opened between the Space Shuttle Endeavour and the station. In front, from the left, are Sergei K. Krikalev, Brent W. Jett, Jr., William M. Shepherd and Joseph R. Tanner. In back, from the left, are Marc Garneau, Carlos I. Noriega, Yuri P. Gidzenko and Michael J. Bloomfield. A pre-set digital still camera was used to record the scene.
Study of statistical coding for digital TV
NASA Technical Reports Server (NTRS)
Gardenhire, L. W.
1972-01-01
The results are presented for a detailed study to determine a pseudo-optimum statistical code to be installed in a digital TV demonstration test set. Studies of source encoding were undertaken, using redundancy removal techniques in which the picture is reproduced within a preset tolerance. A method of source encoding, which preliminary studies show to be encouraging, is statistical encoding. A pseudo-optimum code was defined and the associated performance of the code was determined. The format was fixed at 525 lines per frame, 30 frames per second, as per commercial standards.
1991-12-01
the cartesian coordinate system, ( hkl ) is the general mathematical representation for a crystal plane. The planar densities of a crystal and the...furnace’s temperature was pre-equilibrated to the pre- set oxidation temperature of 1075 °C. Oxygen was bubbled through DIW at 95 °C to promote the growth...to the pre-set oxidation temperature of 1075 °C. An oxygen flow was initiated at 1 liter per minute to realize a high quality, dry SiO 2 thin-film on
Summary of Aerodynamic Data for Structural Analysis of the B-36 Airplane, Revision 1,
1950-06-01
b° 31 7c aw • 7.700 327d 0 % - 12.900 3 AA_ b• -- 5°O " -00% 6034 8b aw - 4.25 358C - 7.25, 36 6da • 12.550 M 7 ga 6 --10, a - -0.700 389b C11 :x...span loadi, aret 3.v"fl- cleatly accurate ani realistic, anl are not as mcnservative as a oarprison with prese-t test dita ww.d i-ldia-te. a, bAo.’ i
USDA-ARS?s Scientific Manuscript database
Accurate estimation of soil organic carbon (SOC) is crucial to efforts to improve soil fertility and stabilize atmospheric CO2 concentrations by sequestering carbon (C) in soils. Soil organic C measurements are, however, often highly variable and management practices can take a long time to produce ...
Ammonia Optical Sensing by Microring Resonators.
Passaro, Vittorio M N; Dell'Olio, Francesco; De Leonardis, Francesco
2007-11-15
A very compact (device area around 40 μm²) optical ammonia sensor based on amicroring resonator is presented in this work. Silicon-on-insulator technology is used insensor design and a dye doped polymer is adopted as sensing material. The sensor exhibitsa very good linearity and a minimum detectable refractive index shift of sensing materialas low as 8x10 -5 , with a detection limit around 4 ‰.
Target Glint Suppression Technology.
1980-09-01
report is organized into two principal sections. Section 2 addresses the impact of target effects on the noncoherent detection problem associated with...zero pulse-to-pulse correlation. Results are presented for a scanning search radar which is assumed to noncoherently integrate N pulses. Generally...speaking, detection performance is shown to be a maximum when the pulse-to-pulse correlation is a minimum. As a result noncoherent search radars should
NASA Astrophysics Data System (ADS)
Loboda, I. P.; Bogachev, S. A.
2015-07-01
We employ an automated detection algorithm to perform a global study of solar prominence characteristics. We process four months of TESIS observations in the He II 304Å line taken close to the solar minimum of 2008-2009 and mainly focus on quiescent and quiescent-eruptive prominences. We detect a total of 389 individual features ranging from 25×25 to 150×500 Mm2 in size and obtain distributions of many of their spatial characteristics, such as latitudinal position, height, size, and shape. To study their dynamics, we classify prominences as either stable or eruptive and calculate their average centroid velocities, which are found to rarely exceed 3 km/s. In addition, we give rough estimates of mass and gravitational energy for every detected prominence and use these values to estimate the total mass and gravitational energy of all simultaneously existing prominences (1012 - 1014 kg and 1029 - 1031 erg). Finally, we investigate the form of the gravitational energy spectrum of prominences and derive it to be a power-law of index -1.1 ± 0.2.
Bader, Chris; Jesudoss Chelladurai, Jeba; Starling, David E; Jones, Douglas E; Brewer, Matthew T
2017-10-01
Control of parasitic infections may be achieved by eliminating developmental stages present within intermediate hosts, thereby disrupting the parasite life cycle. For several trematodes relevant to human and veterinary medicine, this involves targeting the metacercarial stage found in fish intermediate hosts. Treatment of fish with praziquantel is one potential approach for targeting the metacercaria stage. To date, studies investigating praziquantel-induced metacercarial death in fish rely on counting parasites and visually assessing morphology or movement. In this study, we investigate quantitative methods for detecting praziquantel-induced death using a Posthodiplostomum minimum model. Our results revealed that propidium iodide staining accurately identified praziquantel-induced death and the level of staining was proportional to the concentration of praziquantel. In contrast, detection of ATP, resazurin metabolism, and trypan blue staining were poor indicators of metacercarial death. The propidium iodide method offers an advantage over simple visualization of parasite movement and could be used to determine EC 50 values relevant for comparison of praziquantel sensitivity or resistance. Copyright © 2017 Elsevier Inc. All rights reserved.
Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance
NASA Technical Reports Server (NTRS)
Seasly, Elaine; Dever, Jason; Stuban, Steven M. F.
2016-01-01
Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.
3D facial expression recognition using maximum relevance minimum redundancy geometrical features
NASA Astrophysics Data System (ADS)
Rabiu, Habibu; Saripan, M. Iqbal; Mashohor, Syamsiah; Marhaban, Mohd Hamiruce
2012-12-01
In recent years, facial expression recognition (FER) has become an attractive research area, which besides the fundamental challenges, it poses, finds application in areas, such as human-computer interaction, clinical psychology, lie detection, pain assessment, and neurology. Generally the approaches to FER consist of three main steps: face detection, feature extraction and expression recognition. The recognition accuracy of FER hinges immensely on the relevance of the selected features in representing the target expressions. In this article, we present a person and gender independent 3D facial expression recognition method, using maximum relevance minimum redundancy geometrical features. The aim is to detect a compact set of features that sufficiently represents the most discriminative features between the target classes. Multi-class one-against-one SVM classifier was employed to recognize the seven facial expressions; neutral, happy, sad, angry, fear, disgust, and surprise. The average recognition accuracy of 92.2% was recorded. Furthermore, inter database homogeneity was investigated between two independent databases the BU-3DFE and UPM-3DFE the results showed a strong homogeneity between the two databases.
Natural and anthropogenic radioactivity in the environment of Kopaonik mountain, Serbia.
Mitrović, Branislava; Ajtić, Jelena; Lazić, Marko; Andrić, Velibor; Krstić, Nikola; Vranješ, Borjana; Vićentijević, Mihajlo
2016-08-01
To evaluate the state of the environment in Kopaonik, a mountain in Serbia, the activity concentrations of (4) K, (226)Ra, (232)Th and (137)Cs in five different types of environmental samples are determined by gamma ray spectrometry, and radiological hazard due to terrestrial radionuclides is calculated. The mean activity concentrations of natural radionuclides in the soil are higher than the global average. However, with an exception of two sampling locations, the external radiation hazard index is below one, implying an insignificant radiation hazard. Apart from (40)K, content of the natural radionuclides is predominantly below minimum detectable activities in grass and cow milk, but not in mosses. Although (137)Cs is present in the soil, grass, mosses and herbal plants, its specific activity in cow milk is below minimum detectable activity. Amongst the investigated herbal plants, Vaccinium myrtillus L. shows accumulating properties, as a high content of (137)Cs is detected therein. Therefore, moderation is advised in consuming Vaccinium myrtillus L. tea. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effect of nonideal square-law detection on static calibration in noise-injection radiometers
NASA Technical Reports Server (NTRS)
Hearn, C. P.
1984-01-01
The effect of nonideal square-law detection on the static calibration for a class of Dicke radiometers is examined. It is shown that fourth-order curvature in the detection characteristic adds a nonlinear term to the linear calibration relationship normally ascribed to noise-injection, balanced Dicke radiometers. The minimum error, based on an optimum straight-line fit to the calibration curve, is derived in terms of the power series coefficients describing the input-output characteristics of the detector. These coefficients can be determined by simple measurements, and detection nonlinearity is, therefore, quantitatively related to radiometric measurement error.
42 CFR 84.205 - Facepiece test; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
...; (ii) Two minutes, calisthenic arm movements; (iii) Two minutes, running in place; and (iv) Two minutes, pumping with a tire pump into a 28-liter (1 cubic-foot) container. (4) Each wearer shall not detect the...
Mao, Weihua; Riaz, Nadeem; Lee, Louis; Wiersma, Rodney; Xing, Lei
2008-01-01
The advantage of highly conformal dose techniques such as 3DCRT and IMRT is limited by intrafraction organ motion. A new approach to gain near real-time 3D positions of internally implanted fiducial markers is to analyze simultaneous onboard kV beam and treatment MV beam images (from fluoroscopic or electronic portal image devices). Before we can use this real-time image guidance for clinical 3DCRT and IMRT treatments, four outstanding issues need to be addressed. (1) How will fiducial motion blur the image and hinder tracking fiducials? kV and MV images are acquired while the tumor is moving at various speeds. We find that a fiducial can be successfully detected at a maximum linear speed of 1.6 cm∕s. (2) How does MV beam scattering affect kV imaging? We investigate this by varying MV field size and kV source to imager distance, and find that common treatment MV beams do not hinder fiducial detection in simultaneous kV images. (3) How can one detect fiducials on images from 3DCRT and IMRT treatment beams when the MV fields are modified by a multileaf collimator (MLC)? The presented analysis is capable of segmenting a MV field from the blocking MLC and detecting visible fiducials. This enables the calculation of nearly real-time 3D positions of markers during a real treatment. (4) Is the analysis fast enough to track fiducials in nearly real time? Multiple methods are adopted to predict marker positions and reduce search regions. The average detection time per frame for three markers in a 1024×768 image was reduced to 0.1 s or less. Solving these four issues paves the way to tracking moving fiducial markers throughout a 3DCRT or IMRT treatment. Altogether, these four studies demonstrate that our algorithm can track fiducials in real time, on degraded kV images (MV scatter), in rapidly moving tumors (fiducial blurring), and even provide useful information in the case when some fiducials are blocked from view by the MLC. This technique can provide a gating signal or be used for intra-fractional tumor tracking on a Linac equipped with a kV imaging system. Any motion exceeding a preset threshold can warn the therapist to suspend a treatment session and reposition the patient. PMID:18777916
Detection of Thermal Erosion Gullies from High-Resolution Images Using Deep Learning
NASA Astrophysics Data System (ADS)
Huang, L.; Liu, L.; Jiang, L.; Zhang, T.; Sun, Y.
2017-12-01
Thermal erosion gullies, one type of thermokarst landforms, develop due to thawing of ice-rich permafrost. Mapping the location and extent of thermal erosion gullies can help understand the spatial distribution of thermokarst landforms and their temporal evolution. Remote sensing images provide an effective way for mapping thermokarst landforms, especially thermokarst lakes. However, thermal erosion gullies are challenging to map from remote sensing images due to their small sizes and significant variations in geometric/radiometric properties. It is feasible to manually identify these features, as a few previous studies have carried out. However manual methods are labor-intensive, therefore, cannot be used for a large study area. In this work, we conduct automatic mapping of thermal erosion gullies from high-resolution images by using Deep Learning. Our study area is located in Eboling Mountain (Qinghai, China). Within a 6 km2 peatland area underlain by ice-rich permafrost, at least 20 thermal erosional gullies are well developed. The image used is a 15-cm-resolution Digital Orthophoto Map (DOM) generated in July 2016. First, we extracted 14 gully patches and ten non-gully patches as training data. And we performed image augmentation. Next, we fine-tuned the pre-trained model of DeepLab, a deep-learning algorithm for semantic image segmentation based on Deep Convolutional Neural Networks. Then, we performed inference on the whole DOM and obtained intermediate results in forms of polygons for all identified gullies. At last, we removed misidentified polygons based on a few pre-set criteria on the size and shape of each polygon. Our final results include 42 polygons. Validated against field measurements using GPS, most of the gullies are detected correctly. There are 20 false detections due to the small number and low quality of training images. We also found three new gullies that missed in the field observations. This study shows that (1) despite a challenging mapping task, DeepLab can detect small, irregular-shaped thermal erosion gullies with high accuracy. (2) Automatic detection is critical for mapping thermal erosion gully since manual mapping or field work may miss some targets even in a relatively small region. (3) The quantity and quality of training data are crucial for detection accuracy.
Detection of severe Midwest thunderstorms using geosynchronous satellite data
NASA Technical Reports Server (NTRS)
Adler, R. F.; Markus, M. J.; Fenn, D. D.
1985-01-01
In the present exploration of the effectiveness of severe thunderstorm detection in the Midwestern region of the U.S. by means of approximately 5-min interval geosynchronous satellite data, thunderstorms are defined in IR data as points of relative minimum in brightness temperature T(B) having good time continuity and exhibiting a period of rapid growth. The four parameters of rate of T(B) decrease in the upper troposphere and stratosphere, isotherm expansion, and storm lifetime minimum T(B), are shown to be statistically related to the occurrence of severe weather on four case study days and are combined into a Thunderstorm Index which varies among values from 1 to 9. Storms rating higher than 6 have a much higher probability of severe weather reports, yielding a warning time lead of 15 min for hail and 30 min for the first tornado report.
Production, fixation, and staining of cells on slides for maximum photometric sensitivity
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Harlow, Patrick M.; Vallarino, Lidia M.
1994-07-01
The need to detect increasingly low levels of antigens or polynucleotides in cells requires improvements in both the preparation and the staining of samples. The combination of centrifugal cytology with the use of glyoxal as cross-linking fixative produces monolayers of cells having minimum background fluorescence. Detection can be further improved by the use of a recently developed type of luminescent tag containing a lanthanide(III) ion as the light- emitting center. These novel tags are macrocyclic complexes functionalized with an isothiocyanate group to allow covalent coupling to a biosubstrate. The Eu(III) complex possesses a set of properties -- water solubility, inertness to metal release over a wide pH range, ligand-sensitized narrow-band luminescence, large Stoke's shift, and long excited-state lifetime -- that provides ease of staining as well as maximum signal with minimum interference from background autofluorescence. Luminescence efficiency studies indicate significant solvent effects.
Thermoluminescence response of flat optical fiber subjected to 9 MeV electron irradiations
NASA Astrophysics Data System (ADS)
Hashim, S.; Omar, S. S. Che; Ibrahim, S. A.; Hassan, W. M. S. Wan; Ung, N. M.; Mahdiraji, G. A.; Bradley, D. A.; Alzimami, K.
2015-01-01
We describe the efforts of finding a new thermoluminescent (TL) media using pure silica flat optical fiber (FF). The present study investigates the dose response, sensitivity, minimum detectable dose and glow curve of FF subjected to 9 MeV electron irradiations with various dose ranges from 0 Gy to 2.5 Gy. The above-mentioned TL properties of the FF are compared with commercially available TLD-100 rods. The TL measurements of the TL media exhibit a linear dose response over the delivered dose using a linear accelerator. We found that the sensitivity of TLD-100 is markedly 6 times greater than that of FF optical fiber. The minimum detectable dose was found to be 0.09 mGy for TLD-100 and 8.22 mGy for FF. Our work may contribute towards the development of a new dosimeter for personal monitoring purposes.
NASA Astrophysics Data System (ADS)
Szu, Harold H.; Buss, James R.; Kopriva, Ivica
2004-04-01
We proposed the physics approach to solve a physical inverse problem, namely to choose the unique equilibrium solution (at the minimum free energy: H= E - ToS, including the Wiener, l.m.s E, and ICA, Max S, as special cases). The "unsupervised classification" presumes that required information must be learned and derived directly and solely from the data alone, in consistence with the classical Duda-Hart ATR definition of the "unlabelled data". Such truly unsupervised methodology is presented for space-variant imaging processing for a single pixel in the real world case of remote sensing, early tumor detections and SARS. The indeterminacy of the multiple solutions of the inverse problem is regulated or selected by means of the absolute minimum of isothermal free energy as the ground truth of local equilibrium condition at the single-pixel foot print.
Optical tomographic detection of rheumatoid arthritis with computer-aided classification schemes
NASA Astrophysics Data System (ADS)
Klose, Christian D.; Klose, Alexander D.; Netz, Uwe; Beuthan, Jürgen; Hielscher, Andreas H.
2009-02-01
A recent research study has shown that combining multiple parameters, drawn from optical tomographic images, leads to better classification results to identifying human finger joints that are affected or not affected by rheumatic arthritis RA. Building up on the research findings of the previous study, this article presents an advanced computer-aided classification approach for interpreting optical image data to detect RA in finger joints. Additional data are used including, for example, maximum and minimum values of the absorption coefficient as well as their ratios and image variances. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index and area under the curve AUC. Results were compared to different benchmarks ("gold standard"): magnet resonance, ultrasound and clinical evaluation. Maximum accuracies (AUC=0.88) were reached when combining minimum/maximum-ratios and image variances and using ultrasound as gold standard.
Urinary orotic acid-to-creatinine ratios in cats with hepatic lipidosis.
VanSteenhouse, J L; Dimski, D S; Swenson, D H; Taboada, J
1999-06-01
To determine urinary orotic acid (OA) concentration and evaluate the urinary OA-to-creatinine ratio (OACR) in cats with hepatic lipidosis (HL). 20 cats with HL and 20 clinically normal cats. Hepatic lipidosis was diagnosed on the basis of clinical signs, results of serum biochemical analyses, exclusion of other concurrent illness, and cytologic or histologic evaluation of liver biopsy specimens. Urine samples were collected from each cat and frozen at -20 C until assayed. Urine creatinine concentrations were determined, using an alkaline picrate method followed by spectrophotometric assay. Urine OA concentration was determined, using high-performance liquid chromatography. Minimum amount of detectable OA in feline urine was 1 microg/ml. Because of small interfering peaks near the base of the OA peak, the minimum quantifiable concentration of OA was determined to be 5 microg/ml. Urinary OACR was compared in both groups of cats. Differences in urinary OACR were not detected between clinically normal cats and cats with HL. Peaks were not detected for urinary OA in any of the 20 clinically normal cats. Of the 20 HL cats, 14 did not have detectable peaks for urinary OA. Of the 6 HL cats that had detectable urinary OA peaks, 3 had values of <5 microg/ml. Apparently, OACR does not increase significantly in cats with HL. Urinary OACR is not a useful diagnostic test for HL in cats.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Wenfang; Du, Jinjin; Wen, Ruijuan
We have investigated the transmission spectra of a Fabry-Perot interferometer (FPI) with squeezed vacuum state injection and non-Gaussian detection, including photon number resolving detection and parity detection. In order to show the suitability of the system, parallel studies were made of the performance of two other light sources: coherent state of light and Fock state of light either with classical mean intensity detection or with non-Gaussian detection. This shows that by using the squeezed vacuum state and non-Gaussian detection simultaneously, the resolution of the FPI can go far beyond the cavity standard bandwidth limit based on the current techniques. Themore » sensitivity of the scheme has also been explored and it shows that the minimum detectable sensitivity is better than that of the other schemes.« less
Rosotti, Giovanni P; Juhasz, Attila; Booth, Richard A; Clarke, Cathie J
2016-07-01
We investigate the minimum planet mass that produces observable signatures in infrared scattered light and submillimetre (submm) continuum images and demonstrate how these images can be used to measure planet masses to within a factor of about 2. To this end, we perform multi-fluid gas and dust simulations of discs containing low-mass planets, generating simulated observations at 1.65, 10 and 850 μm. We show that the minimum planet mass that produces a detectable signature is ∼15 M ⊕ : this value is strongly dependent on disc temperature and changes slightly with wavelength (favouring the submm). We also confirm previous results that there is a minimum planet mass of ∼20 M ⊕ that produces a pressure maximum in the disc: only planets above this threshold mass generate a dust trap that can eventually create a hole in the submm dust. Below this mass, planets produce annular enhancements in dust outwards of the planet and a reduction in the vicinity of the planet. These features are in steady state and can be understood in terms of variations in the dust radial velocity, imposed by the perturbed gas pressure radial profile, analogous to a traffic jam. We also show how planet masses can be derived from structure in scattered light and submm images. We emphasize that simulations with dust need to be run over thousands of planetary orbits so as to allow the gas profile to achieve a steady state and caution against the estimation of planet masses using gas-only simulations.
Tak, Erwin C P M; van Hespen, Ariëtte T H; Verhaak, Peter F M; Eekhof, Just; Hopman-Rock, Marijke
2016-07-01
Even though the prevalence of mental disorders and social problems is high among elderly patients, it is difficult to detect these in a primary (home) care setting. Goal was the development and preliminary validation of a short observation list to detect six problem areas: anxiety, depression, cognition, suspicion, loneliness, and somatisation. A draft list of indicators identified from a short review of the literature and the opinions of 22 experts was evaluated by general practitioners (GPs) and home care organisations for feasibility. It was then used by GPs and home care personnel to observe patients, who also completed validated tests for psychological disorders (General Health Questionnaire 12 item version (GHQ-12)), depression (Geriatric Depression Scale 15-item version (GDS-15)), anxiety and suspicion (Symptom Checklist-90 (SCL-90)), loneliness (University of California, Los Angeles (UCLA)), somatisation (Illness Attitude Scale (IAS)), and cognition (Mini-Mental State Examination (MMSE)). GPs and home care personnel observed 180 patients (mean age 78.4 years; 66% female) and evaluated the draft list during a regular visit. Cronbach's α was 0.87 for the draft list and ≥0.80 for the draft problem areas (loneliness and suspicion excepted). Principal component analysis identified six components (cognition, depression + loneliness, somatisation, anxiety + suspicion, depression (other signs), and an ambiguous component). Convergent validity was shown for the indicators list as a whole (using the GHQ-12), and the subscales of depression, anxiety, loneliness, cognition, and somatisation. Using pre-set agreed criteria, the list was reduced to 14 final indicators divided over five problem areas. The Observation List for mental disorders and social Problems (OLP) proved to be preliminarily valid, reliable, and feasible for use in primary and home care settings. Copyright © John Wliey & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Enhancing reproducibility of ultrasonic measurements by new users
NASA Astrophysics Data System (ADS)
Pramanik, Manojit; Gupta, Madhumita; Krishnan, Kajoli Banerjee
2013-03-01
Perception of operator influences ultrasound image acquisition and processing. Lower costs are attracting new users to medical ultrasound. Anticipating an increase in this trend, we conducted a study to quantify the variability in ultrasonic measurements made by novice users and identify methods to reduce it. We designed a protocol with four presets and trained four new users to scan and manually measure the head circumference of a fetal phantom with an ultrasound scanner. In the first phase, the users followed this protocol in seven distinct sessions. They then received feedback on the quality of the scans from an expert. In the second phase, two of the users repeated the entire protocol aided by visual cues provided to them during scanning. We performed off-line measurements on all the images using a fully automated algorithm capable of measuring the head circumference from fetal phantom images. The ground truth (198.1±1.6 mm) was based on sixteen scans and measurements made by an expert. Our analysis shows that: (1) the inter-observer variability of manual measurements was 5.5 mm, whereas the inter-observer variability of automated measurements was only 0.6 mm in the first phase (2) consistency of image appearance improved and mean manual measurements was 4-5 mm closer to the ground truth in the second phase (3) automated measurements were more precise, accurate and less sensitive to different presets compared to manual measurements in both phases. Our results show that visual aids and automation can bring more reproducibility to ultrasonic measurements made by new users.
Neumann, K; Holler-Zittlau, I; van Minnen, S; Sick, U; Zaretsky, Y; Euler, H A
2011-01-01
The German Kindersprachscreening (KiSS) is a universal speech and language screening test for large-scale identification of Hessian kindergarten children requiring special educational language training or clinical speech/language therapy. To calculate the procedural screening validity, 257 children (aged 4.0 to 4.5 years) were tested using KiSS and four language tests (Reynell Development Language Scales III, Patholinguistische Diagnostik, PLAKSS, AWST-R). The majority or consensus judgements of three speech-language professionals, based on the language test results, served as a reference criterion. The base (fail) rates of the professionals were either self-determined or preset based on known prevalence rates. Screening validity was higher for preset than for self-determined base rates due to higher inter-judge agreement. The confusion matrices of the overall index classification of the KiSS (speech-language abnormalities with educational or clinical needs) with the fixed base rate expert judgement about language impairment, including fluency or voice disorders, yielded a sensitivity of 88% and a specificity of 78%, for just language impairment 84% and 75%, respectively. Specificities for disorders requiring clinical diagnostics in the KiSS (language impairment alone or combined with fluency/voice disorders) related to the test-based consensus expert judgment was about 93%. Sensitivities were unsatisfactory because the differentiation between educational and clinical needs requires improvement. Since the judgement concordances between the speech-language professionals was only moderate, the development of a comprehensive German reference test for speech and language disorders with evidence-based algorithmic decision rules rather than subjective clinical judgement is advocated.
Foreign body detection in food materials using compton scattered x-rays
NASA Astrophysics Data System (ADS)
McFarlane, Nigel James Bruce
This thesis investigated the application of X-ray Compton scattering to the problem of foreign body detection in food. The methods used were analytical modelling, simulation and experiment. A criterion was defined for detectability, and a model was developed for predicting the minimum time required for detection. The model was used to predict the smallest detectable cubes of air, glass, plastic and steel. Simulations and experiments were performed on voids and glass in polystyrene phantoms, water, coffee and muesli. Backscatter was used to detect bones in chicken meat. The effects of geometry and multiple scatter on contrast, signal-to-noise, and detection time were simulated. Compton scatter was compared with transmission, and the effect of inhomogeneity was modelled. Spectral shape was investigated as a means of foreign body detection. A signal-to-noise ratio of 7.4 was required for foreign body detection in food. A 0.46 cm cube of glass or a 1.19 cm cube of polystyrene were detectable in a 10 cm cube of water in one second. The minimum time to scan a whole sample varied as the 7th power of the foreign body size, and the 5th power of the sample size. Compton scatter inspection produced higher contrasts than transmission, but required longer measurement times because of the low number of photon counts. Compton scatter inspection of whole samples was very slow compared to production line speeds in the food industry. There was potential for Compton scatter in applications which did not require whole-sample scanning, such as surface inspection. There was also potential in the inspection of inhomogeneous samples. The multiple scatter fraction varied from 25% to 55% for 2 to 10 cm cubes of water, but did not have a large effect on the detection time. The spectral shape gave good contrasts and signal-to-noise ratios in the detection of chicken bones.
Taylor, Alexander J; Granwehr, Josef; Lesbats, Clémentine; Krupa, James L; Six, Joseph S; Pavlovskaya, Galina E; Thomas, Neil R; Auer, Dorothee P; Meersmann, Thomas; Faas, Henryk M
2016-01-01
Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI) using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.
Not Available
1981-01-29
Temperature profiles at elevated temperature conditions are monitored by use of an elongated device having two conductors spaced by the minimum distance required to normally maintain an open circuit between them. The melting point of one conductor is selected at the elevated temperature being detected, while the melting point of the other is higher. As the preselected temperature is reached, liquid metal will flow between the conductors creating short circuits which are detectable as to location.
Tokarz, Richard D.
1983-01-01
Temperature profiles at elevated temperature conditions are monitored by use of an elongated device having two conductors spaced by the minimum distance required to normally maintain an open circuit between them. The melting point of one conductor is selected at the elevated temperature being detected, while the melting point of the other is higher. As the preselected temperature is reached, liquid metal will flow between the conductors, creating short circuits which are detectable as to location.
Night Vision Laboratory Static Performance Model for Thermal Viewing Systems
1975-04-01
Research and Development Technical Report f ECOM- • i’.__1’=• =•NIGHT VISION LABORATORY STATIC PERFORMANCE MODEL 1 S1=• : FOR THERMAL VIEWING...resolvable temperature Infrared imaging Minimum detectable temperature1.Detection and recognition performance Night visi,-)n Noise equivalent temperature...modulation transfer function (MTF). The noise charactcristics are specified by the noise equivalent temper- ature difference (NE AT), The next sections
Liu, Anne; Fong, Amie; Becket, Elinne; Yuan, Jessica; Tamae, Cindy; Medrano, Leah; Maiz, Maria; Wahba, Christine; Lee, Catherine; Lee, Kim; Tran, Katherine P; Yang, Hanjing; Hoffman, Robert M; Salih, Anya; Miller, Jeffrey H
2011-03-01
Many studies have examined the evolution of bacterial mutants that are resistant to specific antibiotics, and many of these focus on concentrations at and above the MIC. Here we ask for the minimum concentration at which existing resistant mutants can outgrow sensitive wild-type strains in competition experiments at antibiotic levels significantly below the MIC, and we define a minimum selective concentration (MSC) in Escherichia coli for two antibiotics, which is near 1/5 of the MIC for ciprofloxacin and 1/20 of the MIC for tetracycline. Because of the prevalence of resistant mutants already in the human microbiome, allowable levels of antibiotics to which we are exposed should be below the MSC. Since this concentration often corresponds to low or trace levels of antibiotics, it is helpful to have simple tests to detect such trace levels. We describe a simple ultrasensitive test for detecting the presence of antibiotics and genotoxic agents. The test is based on the use of chromogenic proteins as color markers and the use of single and multiple mutants of Escherichia coli that have greatly increased sensitivity to either a wide range of antibiotics or specific antibiotics, antibiotic families, and genotoxic agents. This test can detect ciprofloxacin at 1/75 of the MIC.
Time and frequency constrained sonar signal design for optimal detection of elastic objects.
Hamschin, Brandon; Loughlin, Patrick J
2013-04-01
In this paper, the task of model-based transmit signal design for optimizing detection is considered. Building on past work that designs the spectral magnitude for optimizing detection, two methods for synthesizing minimum duration signals with this spectral magnitude are developed. The methods are applied to the design of signals that are optimal for detecting elastic objects in the presence of additive noise and self-noise. Elastic objects are modeled as linear time-invariant systems with known impulse responses, while additive noise (e.g., ocean noise or receiver noise) and acoustic self-noise (e.g., reverberation or clutter) are modeled as stationary Gaussian random processes with known power spectral densities. The first approach finds the waveform that preserves the optimal spectral magnitude while achieving the minimum temporal duration. The second approach yields a finite-length time-domain sequence by maximizing temporal energy concentration, subject to the constraint that the spectral magnitude is close (in a least-squares sense) to the optimal spectral magnitude. The two approaches are then connected analytically, showing the former is a limiting case of the latter. Simulation examples that illustrate the theory are accompanied by discussions that address practical applicability and how one might satisfy the need for target and environmental models in the real-world.
Farley, Carlton; Kassu, Aschalew; Bose, Nayana; Jackson-Davis, Armitra; Boateng, Judith; Ruffin, Paul; Sharma, Anup
2017-06-01
A short distance standoff Raman technique is demonstrated for detecting economically motivated adulteration (EMA) in extra virgin olive oil (EVOO). Using a portable Raman spectrometer operating with a 785 nm laser and a 2-in. refracting telescope, adulteration of olive oil with grapeseed oil and canola oil is detected between 1% and 100% at a minimum concentration of 2.5% from a distance of 15 cm and at a minimum concentration of 5% from a distance of 1 m. The technique involves correlating the intensity ratios of prominent Raman bands of edible oils at 1254, 1657, and 1441 cm -1 to the degree of adulteration. As a novel variation in the data analysis technique, integrated intensities over a spectral range of 100 cm -1 around the Raman line were used, making it possible to increase the sensitivity of the technique. The technique is demonstrated by detecting adulteration of EVOO with grapeseed and canola oils at 0-100%. Due to the potential of this technique for making measurements from a convenient distance, the short distance standoff Raman technique has the promise to be used for routine applications in food industry such as identifying food items and monitoring EMA at various checkpoints in the food supply chain and storage facilities.
Reflective measurement of water concentration using millimeter wave illumination
NASA Astrophysics Data System (ADS)
Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren
2011-04-01
THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.
Ma, Chi; Yu, Lifeng; Chen, Baiyu; Favazza, Christopher; Leng, Shuai; McCollough, Cynthia
2016-04-01
Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model's template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, [Formula: see text], was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using [Formula: see text] from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO.
Ma, Chi; Yu, Lifeng; Chen, Baiyu; Favazza, Christopher; Leng, Shuai; McCollough, Cynthia
2016-01-01
Abstract. Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model’s template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, Az, was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using Az from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO. PMID:27284547
Tactical Miniature Crystal Oscillator.
1980-08-01
manufactured by this process are expected to require 30 days to achieve minimum aging rates. (4) FUNDEMENTAL CRYSTAL RETRACE MEASUREMENT. An important crystal...considerable measurement time to detect differences and characterize components. Before investing considerable time in a candidate reactive element, a
NASA Astrophysics Data System (ADS)
Silverman, N. L.; Maneta, M. P.
2016-06-01
Detecting long-term change in seasonal precipitation using ground observations is dependent on the representativity of the point measurement to the surrounding landscape. In mountainous regions, representativity can be poor and lead to large uncertainties in precipitation estimates at high elevations or in areas where observations are sparse. If the uncertainty in the estimate is large compared to the long-term shifts in precipitation, then the change will likely go undetected. In this analysis, we examine the minimum detectable change across mountainous terrain in western Montana, USA. We ask the question: What is the minimum amount of change that is necessary to be detected using our best estimates of precipitation in complex terrain? We evaluate the spatial uncertainty in the precipitation estimates by conditioning historic regional climate model simulations to ground observations using Bayesian inference. By using this uncertainty as a null hypothesis, we test for detectability across the study region. To provide context for the detectability calculations, we look at a range of future scenarios from the Coupled Model Intercomparison Project 5 (CMIP5) multimodel ensemble downscaled to 4 km resolution using the MACAv2-METDATA data set. When using the ensemble averages we find that approximately 65% of the significant increases in winter precipitation go undetected at midelevations. At high elevation, approximately 75% of significant increases in winter precipitation are undetectable. Areas where change can be detected are largely controlled by topographic features. Elevation and aspect are key characteristics that determine whether or not changes in winter precipitation can be detected. Furthermore, we find that undetected increases in winter precipitation at high elevation will likely remain as snow under climate change scenarios. Therefore, there is potential for these areas to offset snowpack loss at lower elevations and confound the effects of climate change on water resources.
Compact TDLAS based sensor design using interband cascade lasers for mid-IR trace gas sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Lei; Tittel, Frank K.; Li, Chunguang
2016-02-25
Two compact TDLAS sensor systems based on different structural optical cores were developed. The two optical cores combine two recent developments, gallium antimonide (GaSb)-based ICL and a compact multipass gas cell (MPGC) with the goal to create compact TDLAS based sensors for the mid-IR gas detection with high detection sensitivity and low power consumption. The sensors achieved minimum detection limits of ~5 ppbv and ~8 ppbv, respectively, for CH 4 and C 2H 6 concentration measurements with a 3.7-W power consumption.