Protocol deviations before and after IV tPA in community hospitals
Adelman, Eric E.; Scott, Phillip A.; Skolarus, Lesli E.; Fox, Allison K.; Frederiksen, Shirley M.; Meurer, William J.
2015-01-01
Background Protocol deviations before and after tPA treatment for ischemic stroke are common. It is unclear if patient or hospital factors predict protocol deviations. We examined predictors of protocol deviations and the effects of protocol violations on symptomatic intracerebral hemorrhage. Methods We used data from the INSTINCT trial, a cluster-randomized, controlled trial evaluating the efficacy of a barrier assessment and educational intervention to increase appropriate tPA use in 24 Michigan community hospitals, to review tPA treatments between 2007 and 2010. Protocol violations were defined as deviations from the standard tPA protocol, both before and after treatment. Multi-level logistic regression models were fitted to determine if patient and hospital variables were associated with pre-treatment or post-treatment protocol deviations. Results During the study, 557 patients (mean age 70; 52% male; median NIHSS 12) were treated with tPA. Protocol deviations occurred in 233 (42%) patients: 16% had pre-treatment deviations, 35% had post-treatment deviations, and 9% had both. The most common protocol deviations included elevated post-treatment blood pressure, antithrombotic agent use within 24 hours of treatment, and elevated pre-treatment blood pressure. Protocol deviations were not associated with symptomatic intracerebral hemorrhage, stroke severity, or hospital factors. Older age was associated with pre-treatment protocol deviations (adjusted OR 0.52; 95% confidence interval 0.30-0.92). Pre-treatment deviations were associated with post-treatment deviations (adjusted OR 3.20; 95% confidence interval 1.91-5.35). Conclusions Protocol deviations were not associated with symptomatic intracerebral hemorrhage. Aside from age, patient and hospital factors were not associated with protocol deviations. PMID:26419527
Potential Acceptability of a Pediatric Ventilator Management Computer Protocol.
Sward, Katherine A; Newth, Christopher J L; Khemani, Robinder G; Page, Kent; Meert, Kathleen L; Carcillo, Joseph A; Shanley, Thomas P; Moler, Frank W; Pollack, Murray M; Dalton, Heidi J; Wessel, David L; Berger, John T; Berg, Robert A; Harrison, Rick E; Doctor, Allan; Dean, J Michael; Holobkov, Richard; Jenkins, Tammara L; Nicholson, Carol E
2017-11-01
To examine issues regarding the granularity (size/scale) and potential acceptability of recommendations in a ventilator management protocol for children with pediatric acute respiratory distress syndrome. Survey/questionnaire. The eight PICUs in the Collaborative Pediatric Critical Care Research Network. One hundred twenty-two physicians (attendings and fellows). None. We used an online questionnaire to examine attitudes and assessed recommendations with 50 clinical scenarios. Overall 80% of scenario recommendations were accepted. Acceptance did not vary by provider characteristics but did vary by ventilator mode (high-frequency oscillatory ventilation 83%, pressure-regulated volume control 82%, pressure control 75%; p = 0.002) and variable adjusted (ranging from 88% for peak inspiratory pressure and 86% for FIO2 changes to 69% for positive end-expiratory pressure changes). Acceptance did not vary based on child size/age. There was a preference for smaller positive end-expiratory pressure changes but no clear granularity preference for other variables. Although overall acceptance rate for scenarios was good, there was little consensus regarding the size/scale of ventilator setting changes for children with pediatric acute respiratory distress syndrome. An acceptable protocol could support robust evaluation of ventilator management strategies. Further studies are needed to determine if adherence to an explicit protocol leads to better outcomes.
Chesnut, Randall M; Temkin, Nancy; Dikmen, Sureyya; Rondina, Carlos; Videtta, Walter; Petroni, Gustavo; Lujan, Silvia; Alanis, Victor; Falcao, Antonio; de la Fuenta, Gustavo; Gonzalez, Luis; Jibaja, Manuel; Lavarden, Arturo; Sandi, Freddy; Mérida, Roberto; Romero, Ricardo; Pridgeon, Jim; Barber, Jason; Machamer, Joan; Chaddock, Kelley
2018-01-01
The imaging and clinical examination (ICE) algorithm used in the Benchmark Evidence from South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial is the only prospectively investigated clinical protocol for traumatic brain injury management without intracranial pressure (ICP) monitoring. As the default literature standard, it warrants careful evaluation. We present the ICE protocol in detail and analyze the demographics, outcome, treatment intensity, frequency of intervention usage, and related adverse events in the ICE-protocol cohort. The 167 ICE protocol patients were young (median 29 years) with a median Glasgow Coma Scale motor score of 4 but with anisocoria or abnormal pupillary reactivity in 40%. This protocol produced outcomes not significantly different from those randomized to the monitor-based protocol (favorable 6-month extended Glasgow Outcome Score in 39%; 41% mortality rate). Agents commonly employed to treat suspected intracranial hypertension included low-/moderate-dose hypertonic saline (72%) and mannitol (57%), mild hyperventilation (adjusted partial pressure of carbon dioxide 30-35 mm Hg in 73%), and pressors to maintain cerebral perfusion (62%). High-dose hyperosmotics or barbiturates were uncommonly used. Adverse event incidence was low and comparable to the BEST TRIP monitored group. Although this protocol should produce similar/acceptable results under circumstances comparable to those in the trial, influences such as longer pre-hospital times and non-specialist transport personnel, plus an intensive care unit model of aggressive physician-intensive care by small groups of neurotrauma-focused intensivists, which differs from most high-resource models, support caution in expecting the same results in dissimilar settings. Finally, this protocol's ICP-titration approach to suspected intracranial hypertension (vs. crisis management for monitored ICP) warrants further study.
Iskandar, Michèle M.; Lands, Larry C.; Sabally, Kebba; Azadi, Behnam; Meehan, Brian; Mawji, Nadir; Skinner, Cameron D.; Kubow, Stan
2015-01-01
Whey proteins have well-established antioxidant and anti-inflammatory bioactivities. High hydrostatic pressure processing of whey protein isolates increases their in vitro digestibility resulting in enhanced antioxidant and anti-inflammatory effects. This study compared the effects of different digestion protocols on the digestibility of pressurized (pWPI) and native (nWPI) whey protein isolates and the antioxidant and anti-inflammatory properties of the hydrolysates. The pepsin-pancreatin digestion protocol was modified to better simulate human digestion by adjusting temperature and pH conditions, incubation times, enzymes utilized, enzyme-to-substrate ratio and ultrafiltration membrane molecular weight cut-off. pWPI showed a significantly greater proteolysis rate and rate of peptide appearance regardless of digestion protocol. Both digestion methods generated a greater relative abundance of eluting peptides and the appearance of new peptide peaks in association with pWPI digestion in comparison to nWPI hydrolysates. Hydrolysates of pWPI from both digestion conditions showed enhanced ferric-reducing antioxidant power relative to nWPI hydrolysates. Likewise, pWPI hydrolysates from both digestion protocols showed similar enhanced antioxidant and anti-inflammatory effects in a respiratory epithelial cell line as compared to nWPI hydrolysates. These findings indicate that regardless of considerable variations of in vitro digestion protocols, pressurization of WPI leads to more efficient digestion that improves its antioxidant and anti-inflammatory properties. PMID:28231198
Iskandar, Michèle M; Lands, Larry C; Sabally, Kebba; Azadi, Behnam; Meehan, Brian; Mawji, Nadir; Skinner, Cameron D; Kubow, Stan
2015-05-28
Whey proteins have well-established antioxidant and anti-inflammatory bioactivities. High hydrostatic pressure processing of whey protein isolates increases their in vitro digestibility resulting in enhanced antioxidant and anti-inflammatory effects. This study compared the effects of different digestion protocols on the digestibility of pressurized (pWPI) and native (nWPI) whey protein isolates and the antioxidant and anti-inflammatory properties of the hydrolysates. The pepsin-pancreatin digestion protocol was modified to better simulate human digestion by adjusting temperature and pH conditions, incubation times, enzymes utilized, enzyme-to-substrate ratio and ultrafiltration membrane molecular weight cut-off. pWPI showed a significantly greater proteolysis rate and rate of peptide appearance regardless of digestion protocol. Both digestion methods generated a greater relative abundance of eluting peptides and the appearance of new peptide peaks in association with pWPI digestion in comparison to nWPI hydrolysates. Hydrolysates of pWPI from both digestion conditions showed enhanced ferric-reducing antioxidant power relative to nWPI hydrolysates. Likewise, pWPI hydrolysates from both digestion protocols showed similar enhanced antioxidant and anti-inflammatory effects in a respiratory epithelial cell line as compared to nWPI hydrolysates. These findings indicate that regardless of considerable variations of in vitro digestion protocols, pressurization of WPI leads to more efficient digestion that improves its antioxidant and anti-inflammatory properties.
Ramadhan, Ali; Thompson, Geoffrey A; Maroulakos, Georgios; Berzins, David
2018-04-30
Research evaluating load-to-failure of pressed lithium disilicate glass-ceramic (LDGC) with a clinically validated test after adjustment and repair procedures is scarce. The purpose of this in vitro study was to investigate the effect of the simulated chairside adjustment of the intaglio surface of monolithic pressed LDGC and procedures intended to repair damage. A total of 423 IPS e.max Press (Ivoclar Vivadent AG) disks (15 mm diameter, 1 mm height) were used in the study. The material was tested by using an equibiaxial loading arrangement (n≥30/group) and a contact pressure test (n≥20/group). Specimens were assigned to 1 of 14 groups. One-half was assigned to the equibiaxial load test and the other half underwent contact pressure testing. Testing was performed in 2 parts, before glazing and after glazing. Before-glazing specimens were devested and entered in the test protocol, while after-glazing specimens were devested and glazed before entering the test protocol. Equibiaxial flexure test specimens were placed on a ring-on-ring apparatus and loaded until failure. Contact pressure specimens were cemented to epoxy resin blocks with a resin cement and loaded with a 50-mm diameter hemisphere until failure. Tests were performed on a universal testing machine with a crosshead speed of 0.5 mm/min. Weibull statistics and likelihood ratio contour plots determined intergroup differences (95% confidence bounds). Before glazing, the equibiaxial flexural strength test and the Weibull and likelihood ratio contour plots demonstrated a significantly higher failure strength for 1EC (188 MPa) than that of the damaged and/or repaired groups. Glazing following diamond-adjustment (1EGG) was the most beneficial post-damage procedure (176 MPa). Regarding the contact pressure test, the Weibull and likelihood ratio contour plots revealed no significant difference between the 1PC (98 MPa) and 1PGG (98 MPa) groups. Diamond-adjustment, without glazing (1EG and 1PG), resulted in the next-to-lowest equibiaxial flexure strength and the lowest contact pressure. After glazing, the strength of all the groups, when subjected to glazing following devesting, increased in comparison with corresponding groups in the before-glazing part of the study. A glazing treatment improved the mechanical properties of diamond-adjusted IPS e.max Press disks when evaluated by equibiaxial flexure and contact pressure tests. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Wilborn, Doris; Grittner, Ulrike; Dassen, Theo; Kottner, Jan
2010-12-01
The objective of this study was to describe the relationship between the German National Expert Standard Pressure Ulcer Prevention and the pressure ulcer prevalence in German nursing homes and hospitals. The patient outcome pressure ulcer does not only depend on individual characteristics of patients, but also on institutional factors. In Germany, National Expert Standards are evidence-based instruments that build the basis of continuing improvement in health care quality. It is expected that after having implemented the National Expert Standard Pressure Ulcer Prevention, the number of pressure ulcers should decrease in health care institutions. The analysed data were obtained from two cross-sectional studies from 2004-2005. A multilevel analysis was performed to show the impact of the National Expert Standard Pressure Ulcer Prevention on pressure ulcer prevalence. A total of 41.5% of hospitals and 38.8% of the nursing homes claimed to use the National Expert Standard in the process of developing their local protocols. The overall pressure ulcer prevalence grade 2-4 was 4.7%. Adjusted for hospital departments, survey year and individual characteristics, there was no significant difference in the prevalence of pressure ulcers between institutions that refer to the National Expert Standard or those referring to other sources in developing their local protocols (OR=1.14, 95% CI=0.90-1.44). There was no empirical evidence demonstrating that local protocols of pressure ulcer prevention based on the National Expert Standard were superior to local protocols which refer other sources of knowledge with regard to the pressure ulcer prevalence. The use of the National Expert Standard Pressure Ulcer Prevention can neither be recommended nor be refused. The recent definition of implementation of Expert Standards should be mandatory for all health care institutions which introduce Expert Standards. © 2010 Blackwell Publishing Ltd.
Gene delivery by direct injection (microinjection) using a controlled-flow system.
Dean, David A
2006-12-01
INTRODUCTIONThis protocol describes a method for constant-flow microinjection using the Pneumatic PicoPump (World Precision Instruments). This type of system is very simple and can be assembled on a relatively low budget. In this method, a constant flow of sample is delivered from the tip of the pipette, and the amount of sample injected into the cell is determined by how long the pipette remains in the cell. A typical system is composed of a pressure regulator that can be adjusted for two pressures (back pressure and injection pressure), a capillary holder, and a coarse and fine micromanipulator.
Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Hammel, Gertrud; Bramlage, Peter
2017-05-01
The purpose of the study was to validate the ambulatory blood pressure monitoring (ABPM) device custo screen pediatric in children aged 3 to 12 years according to the International Protocol of the European Society of Hypertension (ESH-IP revision 2010). Thirty-three children were included and systolic and diastolic blood pressure measurements were performed according to the ESH-IP. The protocol was modified for children considering data from the German Health Interview and Examination Survey for Children and Adolescents (KIGGS). The custo screen pediatric met all the requirements of the ESH-IP. The mean difference between the test device and the reference was -1.4 ± 3.0 mmHg for systolic blood pressure (SBP) and -0.7 ± 3.2 mmHg for diastolic blood pressure (DBP). For SBP and DBP, all 99 measurements were within the absolute difference of 10 mmHg between the test device and the reference. As to part 2 of the protocol, for DBP in all subjects, two out of three measurements were within 5 mmHg between the device and the standard, whereas for SBP in 32 of 33 subjects, two out of three measurements were within this range. The custo screen pediatric met all criteria of the ESH-IP review 2010, modified for children from 3 to about 12 years, and can be recommended for ABPM in children. What is Known: • Validation of blood pressure measuring devices is essential to provide patients with an accurate blood pressure measuring device. • The majority of devices has not been validated in children. What is New: • Prior to the present validation, study protocol adjustments of ESH-IP review 2010 for children were defined according to German Health Interview and Examination Survey for Children and Adolescents 2013 (KIGGS). • The custo screen pediatric test device met all criteria of ESH-IP revision 2010, modified for children, and can be recommended for ABPM in children aged 3 to about 12 years.
Makhsous, Mohsen; Lin, Fang; Knaus, Evan; Zeigler, Mary; Rowles, Diane M; Gittler, Michelle; Bankard, James; Chen, David
2009-11-01
To evaluate whether an individualized cyclic pressure-relief protocol accelerates wound healing in wheelchair users with established pressure ulcers (PrUs). Randomized controlled study. Spinal cord injury clinics. Forty-four subjects, aged 18-79 years, with a Stage II or Stage III PrU, were randomly assigned to the control (n = 22) or treatment (n = 22) groups. Subjects in the treatment group used wheelchairs equipped with an individually adjusted automated seat that provided cyclic pressure relief, and those in the control group used a standard wheelchair. All subjects sat in wheelchairs for a minimum of 4 hours per day for 30 days during their PrU treatment. Wound characteristics were assessed using the Pressure Ulcer Scale for Healing (PUSH) tool and wound dimensions recorded with digital photographs twice a week. Median healing time for a 30% healing relative to initial measurements, the percentage reduction in wound area, and the percentage improvement in PUSH score achieved at the end of the trial were compared between groups. At the end of 30 days, both groups demonstrated a general trend of healing. However, the treatment group was found to take significantly less time to achieve 30% healing for the wound measurement compared with the control group. The percentage improvement of the wound area and PUSH scores were greater in using cyclic seating (45.0 +/- 21.0, P < .003; 29.9 +/- 24. 6, P < .003) compared with standard seating (10.2 +/- 34.9, 5.8 +/- 9.2). The authors' findings show that cyclically relieving pressure in the area of a wound for seated individuals can greatly aid wound healing. The current study provides evidence that the individualized cyclic pressure-relief protocol helps promote pressure wound healing in a clinical setting. The authors concluded that the individualized cyclic pressure relief may have substantial benefits in accelerating the healing process in wheelchair users with existing PrUs, while maintaining the mobility of individuals with SCI during the PrU treatment.
Bioindicators in the MIDUS National Study: Protocol, Measures, Sample, and Comparative Context
Love, Gayle Dienberg; Seeman, Teresa E.; Weinstein, Maxine; Ryff, Carol D.
2010-01-01
Objectives MIDUS is a national study of health and aging among individuals aged 25 to 74 at baseline(1995/96). Longitudinal survey assessments (2004/05), were followed by biological assessments on a subsample aged 35–85. To facilitate public use, we describe the protocol, measures, and sample. Methods Respondents traveled to clinics for a two-day data collection protocol that included fasting blood specimens, 12-hour urine specimen, medical history, physical exam, bone densitometry, a laboratory challenge (heart rate variability, blood pressure, respiration, salivary cortisol). Results Response rates for the biological protocol (N = 1,255) were 39.3%, or 43.1% (adjusting for those who could not be located or contacted). Reasons for non-participation were travel, family obligations, and being too busy. Respondents were comparable to the recruitment pool on most demographic characteristics and health assessments. Discussion Strengths of the protocol vis-à-vis other similar studies include opportunities to link biological factors with diverse content from other MIDUS projects. PMID:20876364
Ferreira, Cesar Biselli; Bassi, Estevão; Lucena, Lucas; Carreta, Hernandez; Miranda, Leandro Costa; Tierno, Paulo Fernando Guimarães Mazorcchi; Amorim, Robson Luis; Zampieri, Fernando Godinho; Malbouisson, Luis Marcelo Sá
2015-01-01
Objective To assess the impact of intracranial pressure monitoring on the short-term outcomes of traumatic brain injury patients. Methods Retrospective observational study including 299 consecutive patients admitted due to traumatic brain injury from January 2011 through July 2012 at a Level 1 trauma center in São Paulo, Brazil. Patients were categorized in two groups according to the measurement of intracranial pressure (measured intracranial pressure and non-measured intracranial pressure groups). We applied a propensity-matched analysis to adjust for possible confounders (variables contained in the Crash Score prognostic algorithm). Results Global mortality at 14 days (16%) was equal to that observed in high-income countries in the CRASH Study and was better than expected based on the CRASH calculator score (20.6%), with a standardized mortality ratio of 0.77. A total of 28 patients received intracranial pressure monitoring (measured intracranial pressure group), of whom 26 were paired in a 1:1 fashion with patients from the non-measured intracranial pressure group. There was no improvement in the measured intracranial pressure group compared to the non-measured intracranial pressure group regarding hospital mortality, 14-day mortality, or combined hospital and chronic care facility mortality. Survival up to 14 days was also similar between groups. Conclusion Patients receiving intracranial pressure monitoring tend to have more severe traumatic brain injuries. However, after adjusting for multiple confounders using propensity scoring, no benefits in terms of survival were observed among intracranial pressure-monitored patients and those managed with a systematic clinical protocol. PMID:26761468
Ferreira, Cesar Biselli; Bassi, Estevão; Lucena, Lucas; Carreta, Hernandez; Miranda, Leandro Costa; Tierno, Paulo Fernando Guimarães Mazorcchi; Amorim, Robson Luis; Zampieri, Fernando Godinho; Malbouisson, Luis Marcelo Sá
2015-01-01
To assess the impact of intracranial pressure monitoring on the short-term outcomes of traumatic brain injury patients. Retrospective observational study including 299 consecutive patients admitted due to traumatic brain injury from January 2011 through July 2012 at a Level 1 trauma center in São Paulo, Brazil. Patients were categorized in two groups according to the measurement of intracranial pressure (measured intracranial pressure and non-measured intracranial pressure groups). We applied a propensity-matched analysis to adjust for possible confounders (variables contained in the Crash Score prognostic algorithm). Global mortality at 14 days (16%) was equal to that observed in high-income countries in the CRASH Study and was better than expected based on the CRASH calculator score (20.6%), with a standardized mortality ratio of 0.77. A total of 28 patients received intracranial pressure monitoring (measured intracranial pressure group), of whom 26 were paired in a 1:1 fashion with patients from the non-measured intracranial pressure group. There was no improvement in the measured intracranial pressure group compared to the non-measured intracranial pressure group regarding hospital mortality, 14-day mortality, or combined hospital and chronic care facility mortality. Survival up to 14 days was also similar between groups. Patients receiving intracranial pressure monitoring tend to have more severe traumatic brain injuries. However, after adjusting for multiple confounders using propensity scoring, no benefits in terms of survival were observed among intracranial pressure-monitored patients and those managed with a systematic clinical protocol.
MRI safety of a programmable shunt assistant at 3 and 7 Tesla.
Mirzayan, M Javad; Klinge, Petra M; Samii, Madjid; Goetz, Friedrich; Krauss, Joachim K
2012-06-01
Several new shunt technologies have been developed to optimize hydrocephalus treatment within the past few years. Overdrainage, however, still remains an unresolved problem. One new technology which may reduce the frequency of this complication is the use of a programmable shunt assistant (proSA). Inactive in a horizontal position, it impedes CSF flow in a vertical position according to a prescribed pressure level ranging from 0 to 40 cm H(2)O. We exposed the proSA valve in an ex vivo protocol to MR systems operating at 3 and 7 Tesla to investigate its MRI safety. Following 3 Tesla exposure, no changes in valve settings were noted. Adjustment to any pressure level was possible thereafter. The mean deflection angle was 23 ± 3°. After exposure to 7 Tesla, however, there were unintended pressure changes, and the mechanism for further adjustment of the valves even disintegrated. According to the results of this study, proSA is safe with heteropolar vertical magnet alignment at 3 Tesla. Following 7 Tesla exposure, the valves lost their functional capability.
The area postrema does not modulate the long-term salt sensitivity of arterial pressure.
Collister, J P; Osborn, J W
1998-10-01
The hindbrain circumventricular organ, the area postrema (AP), receives multiple signals linked to body fluid homeostasis. In addition to baroreceptor input, AP cells contain receptors for ANG II, vasopressin, and atrial natriuretic peptide. Hence, it has been proposed that the AP is critical in long-term adjustments in sympathetic outflow in response to changes in dietary NaCl. The present study was designed to test the hypothesis that long-term control of arterial pressure over a range of dietary NaCl requires an intact AP. Male Sprague-Dawley rats were randomly selected for lesion of the AP (APx) or sham lesion. Three months later, rats were instrumented with radiotelemetry transmitters for continuous monitoring of mean arterial pressure (MAP) and heart rate and were placed in individual metabolic cages. Rats were given 1 wk postoperative recovery. The dietary salt protocol consisted of a 7-day period of 1.0% NaCl (control), 14 days of 4.0% NaCl (high), 7 days of 1.0% NaCl, and finally 14 days of 0.1% NaCl (low). The results are reported as the average arterial pressure observed on the last day of the given dietary salt period: APx (n = 7) 114 +/- 2 (1.0%), 110 +/- 3 (4.0%), 110 +/- 3 (1.0%), and 114 +/- 4 (0.1%) mmHg; sham (n = 6) 115 +/- 2 (1.0%), 114 +/- 3 (4.0%), 111 +/- 3 (1. 0%), and 113 +/- 2 (0.1%) mmHg. Neither group of rats demonstrated significant changes in MAP throughout the entire dietary salt protocol. Furthermore, no significant differences in MAP were detected between groups throughout the protocol. All lesions were histologically verified. These results suggest that the area postrema plays no role in long-term control of arterial pressure during chronic changes in dietary salt.
Protocols for pressure ulcer prevention: are they evidence-based?
Chaves, Lidice M; Grypdonck, Mieke H F; Defloor, Tom
2010-03-01
This study is a report of a study to determine the quality of protocols for pressure ulcer prevention in home care in the Netherlands. If pressure ulcer prevention protocols are evidence-based and practitioners use them correctly in practice, this will result a reduction in pressure ulcers. Very little is known about the evidence-based content and quality of the pressure ulcer prevention protocols. In 2008, current pressure ulcer prevention protocols from 24 home-care agencies in the Netherlands were evaluated. A checklist developed and validated by two pressure ulcer prevention experts was used to assess the quality of the protocols, and weighted and unweighted quality scores were computed and analysed using descriptive statistics. The 24 pressure ulcer prevention protocols had a mean weighted quality score of 63.38 points out of a maximum of 100 (sd 5). The importance of observing the skin at the pressure points at least once a day was emphasized in 75% of the protocols. Only 42% correctly warned against the use of materials that were 'less effective or that could potentially cause harm'. Pressure ulcer prevention commands a reasonable amount of attention in home care, but the incidence of pressure ulcers and lack of a consistent, standardized document for use in actual practice indicate a need for systematic implementation of national pressure ulcer prevention standards in the Netherlands to ensure adherence to the established protocols.
Fernando, Malindu E; Crowther, Robert G; Lazzarini, Peter A; Sangla, Kunwarjit S; Wearing, Scott; Buttner, Petra; Golledge, Jonathan
2016-09-15
Current international guidelines advocate achieving at least a 30 % reduction in maximum plantar pressure to reduce the risk of foot ulcers in people with diabetes. However, whether plantar pressures differ in cases with foot ulcers to controls without ulcers is not clear. The aim of this study was to assess if plantar pressures were higher in patients with active plantar diabetic foot ulcers (cases) compared to patients with diabetes without a foot ulcer history (diabetes controls) and people without diabetes or a foot ulcer history (healthy controls). Twenty-one cases with diabetic foot ulcers, 69 diabetes controls and 56 healthy controls were recruited for this case-control study. Plantar pressures at ten sites on both feet and stance phase duration were measured using a pre-established protocol. Primary outcomes were mean peak plantar pressure, pressure-time integral and stance phase duration. Non-parametric analyses were used with Holm's correction to correct for multiple testing. Binary logistic regression models were used to adjust outcomes for age, sex and body mass index. Median differences with 95 % confidence intervals and Cohen's d values (standardised mean difference) were reported for all significant outcomes. The majority of ulcers were located on the plantar surface of the hallux and toes. When adjusted for age, sex and body mass index, the mean peak plantar pressure and pressure-time integral of toes and the mid-foot were significantly higher in cases compared to diabetes and healthy controls (p < 0.05). The stance phase duration was also significantly higher in cases compared to both control groups (p < 0.05). The main limitations of the study were the small number of cases studied and the inability to adjust analyses for multiple factors. This study shows that plantar pressures are higher in cases with active diabetic foot ulcers despite having a longer stance phase duration which would be expected to lower plantar pressure. Whether plantar pressure changes can predict ulcer healing should be the focus of future research. These results highlight the importance of offloading feet during active ulceration in addition to before ulceration.
Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito
2014-01-01
The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.
Padula, William V
The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. Retrospective observational cohort. We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (-1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (-1.13 cases/quarter; P = .035). Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products.
2017-01-01
PURPOSE: The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. DESIGN: Retrospective observational cohort. SAMPLE AND SETTING: We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. METHODS: We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. RESULTS: Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (−1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (−1.13 cases/quarter; P = .035). CONCLUSIONS: Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products. PMID:28816929
Yan, W L; Li, X S; Wang, Q; Huang, Y D; Zhang, W G; Zhai, X H; Wang, C C; Lee, J H
2015-01-01
To investigate whether the levels of blood pressure and fasting glucose differ among Chinese children of three different ethnicities (i.e., Uyghurs, Kazakhs, and Hans) and whether the differences are explained by childhood obesity. A school-based cross-sectional study was conducted in a large three ethnic pediatric population (n = 6633), whose ages ranged from 7 to 18 years. Anthropometrics and blood pressure were measured using standard protocols. Fasting glucose was measured in a subset of children (n = 2295) who were randomly selected based on ethnicity and age. The age-sex stratified Chinese national cut-offs were used to define obesity and high blood pressure (HBP). The prevalence of HBP, impaired fasting glucose (IFG), mean levels of blood pressure, and glucose were compared among three ethnic groups. 2142 Uyghurs, 2078 Han, and 1997 Kazakhs were analyzed. After adjusting for age and body mass index (BMI), the mean blood pressure for Uyghurs was on average, 2-4 mm Hg lower than those for Hans and Kazakhs. Kazakhs had the lowest mean fasting glucose compared with Hans and Uyghurs (4.5 vs. 5.0 vs. 4.8 mmol/L, respectively). The differences in blood pressure and fasting glucose persisted even after adjusting for age and BMI, and the differences among ethnic groups in blood pressure levels and fasting glucose levels were observed as early as 7-9 years of age. The prevalence of HBP and IFG differed significantly among Uyghurs, Hans, and Kazakhs, and the ethnic differences observed in childhood were consistent with those observed in adults from the same region. While childhood obesity is a significant risk factor for hypertension and elevated glucose, the differences among ethnic groups were not explained by obesity alone.
de Greeff, Annemarie; Shennan, Andrew H
2013-06-01
The Tensoval Duo Control II is an automated upper arm device that uses a combination of oscillometric and auscultatory technology to determine blood pressure noninvasively. The accuracy of this device was assessed according to the British Hypertension Society (BHS) protocol and the European Society of Hypertension International Protocol revision 2010 (ESH-IP2) in an adult population. Ethical approval was obtained. Eighty-five and 33 adult individuals, respectively, were recruited to fulfil the requirements of each protocol. Trained observers took nine sequential same-arm measurements alternating between a mercury sphygmomanometer and the device. The device had to achieve at least a B grade for both systolic and diastolic pressures to pass the BHS protocol and had to fulfil the criteria of all three phases of the ESH-IP2 protocol to receive recommendation. The device achieved an A/A grading for the BHS protocol and passed all three phases of the ESH-IP2 protocol. The mean difference±SD for the BHS/ESH protocols, respectively, was -1.8±6.5/-0.7±5.7 mmHg for systolic pressure and 1.9±5.1/2.4±4.5 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low-pressure, medium-pressure and high-pressure ranges. The Tensoval Duo Control II device is recommended for clinical and home use according to both the BHS and the ESH-IP2 standard.
Periodically Relieving Ischial Sitting Load to Decrease the Risk of Pressure Ulcers
Makhsous, Mohsen; Rowles, Diane M.; Rymer, William Z.; Bankard, James; Nam, Ellis K.; Chen, David; Lin, Fang
2010-01-01
Objective To investigate the relieving effect on interface pressure of an alternate sitting protocol involving a sitting posture that reduces ischial support. Design Repeated measures in 2 protocols on 3 groups of subjects. Setting Laboratory. Participants Twenty able-bodied persons, 20 persons with paraplegia, and 20 persons with tetraplegia. Interventions Two 1-hour protocols were used: alternate and normal plus pushup. In the alternate protocol, sitting posture was alternated every 10 minutes between normal (sitting upright with ischial support) and with partially removed ischial support (WO-BPS) postures; in the normal plus pushup protocol, sitting was in normal posture with pushups (lifting the subject off the seat) performed every 20 minutes. Main Outcome Measure Interface pressure on seat and backrest. Results In WO-BPS posture, the concentrated interface pressure observed around the ischia in normal posture was significantly repositioned to the thighs. By cyclically repositioning the interface pressure, the alternate protocol was superior to the normal plus pushup protocol in terms of a significantly lower average interface pressure over the buttocks. Conclusions A sitting protocol periodically reducing the ischial support helps lower the sitting load on the buttocks, especially the area close to ischial tuberosities. PMID:17601466
Kaitani, Toshiko; Nakagami, Gojiro; Iizaka, Shinji; Fukuda, Takashi; Oe, Makoto; Igarashi, Ataru; Mori, Taketoshi; Takemura, Yukie; Mizokami, Yuko; Sugama, Junko; Sanada, Hiromi
2015-01-01
The high prevalence of severe pressure ulcers (PUs) is an important issue that requires to be highlighted in Japan. In a previous study, we devised an advanced PU management protocol to enable early detection of and intervention for deep tissue injury and critical colonization. This protocol was effective for preventing more severe PUs. The present study aimed to compare the cost-effectiveness of the care provided using an advanced PU management protocol, from a medical provider's perspective, implemented by trained wound, ostomy, and continence nurses (WOCNs), with that of conventional care provided by a control group of WOCNs. A Markov model was constructed for a 1-year time horizon to determine the incremental cost-effectiveness ratio of advanced PU management compared with conventional care. The number of quality-adjusted life-years gained, and the cost in Japanese yen (¥) ($US1 = ¥120; 2015) was used as the outcome. Model inputs for clinical probabilities and related costs were based on our previous clinical trial results. Univariate sensitivity analyses were performed. Furthermore, a Bayesian multivariate probability sensitivity analysis was performed using Monte Carlo simulations with advanced PU management. Two different models were created for initial cohort distribution. For both models, the expected effectiveness for the intervention group using advanced PU management techniques was high, with a low expected cost value. The sensitivity analyses suggested that the results were robust. Intervention by WOCNs using advanced PU management techniques was more effective and cost-effective than conventional care. © 2015 by the Wound Healing Society.
Nascimento, L S; Santos, A C; Lucena, Jms; Silva, Lgo; Almeida, Aem; Brasileiro-Santos, M S
2017-06-02
Resistant hypertension is a specific condition that affects approximately 10% of subjects with hypertension, and is characterized by persistently high blood pressure levels even using therapy of three or more antihypertensive agents or with blood pressure control using therapy with four or more antihypertensive agents. Changes in lifestyle, such as physical exercise, are indicated for controlling blood pressure. However, investigating studies about this therapy in individuals with resistant hypertension are few. This is a randomized controlled clinical trial. Forty-eight patients with resistant hypertension will be submitted to perform four short-term interventions: aerobic exercise sessions (mild-, moderate- and high-intensity) and control session, in random order and on separate days. After the short-term sessions, the patients will be randomly allocated into four groups for 8 weeks of follow-up: mild-, moderate- and high-intensity aerobic exercise, and a control group. The primary outcome is the occurrence of blood pressure reduction (office and ambulatory analysis, and acute and chronic effects). Secondary outcomes are autonomic and hemodynamic mechanisms: cardiac and vasomotor autonomic modulation, spontaneous baroreflex sensitivity, forearm blood flow and vascular resistance. The importance of exercise for hypertension has been known for decades, but little is known about the effects on patients with resistant hypertension. This study will help to understand whether different aerobic exercise intensities can induce different responses, as well as by what mechanisms adjustments in blood pressure levels may occur. ClinicalTrials.gov, ID: NCT02670681 . Registered on 28 January 2016 (first version); Brazilian Registry Platform Clinical Trials: protocol RBR-5q24zh . Registered on 24 June 2015.
Zeng, Wei-Fang; Liu, Ming; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang
2013-08-01
The present study aimed to evaluate the accuracy of the fully automated oscillometric upper-arm blood pressure monitor TM-2656 according to the British Hypertension Society (BHS) Protocol 1993. We recruited individuals until there were 85 eligible participants and their blood pressure could meet the blood pressure distribution requirements specified by the BHS Protocol. For each individual, we sequentially measured the systolic and diastolic blood pressures using a mercury sphygmomanometer (two observers) and the TM-2656 device (one supervisor). Data analysis was carried out according to the BHS Protocol. The device achieved grade A. The percentage of blood pressure differences within 5, 10, and 15 mmHg was 62, 85, and 96%, respectively, for systolic blood pressure, and 71, 93, and 99%, respectively, for diastolic blood pressure. The average (±SD) of the device-observer differences was -2.1±7.8 mmHg (P<0.0001) and -1.1±5.8 mmHg (P<0.0001) for systolic and diastolic blood pressures, respectively. The A&D upper-arm blood pressure monitor TM-2656 has passed the requirements of the BHS Protocol, and can thus be recommended for blood pressure measurement.
Tenten-Diepenmaat, Marloes; Dekker, Joost; Steenbergen, Menno; Huybrechts, Elleke; Roorda, Leo D; van Schaardenburg, Dirkjan; Bus, Sicco A; van der Leeden, Marike
2016-03-01
Improving foot orthoses (FOs) in patients with rheumatoid arthritis (RA) by using in-shoe plantar pressure measurements seems promising. The objectives of this study were to evaluate (1) the outcome on plantar pressure distribution of FOs that were adapted using in-shoe plantar pressure measurements according to a protocol and (2) the protocol feasibility. Forty-five RA patients with foot problems were included in this observational proof-of concept study. FOs were custom-made by a podiatrist according to usual care. Regions of Interest (ROIs) for plantar pressure reduction were selected. According to a protocol, usual care FOs were evaluated using in-shoe plantar pressure measurements and, if necessary, adapted. Plantar pressure-time integrals at the ROIs were compared between the following conditions: (1) no-FO versus usual care FO and (2) usual care FO versus adapted FO. Semi-structured interviews were held with patients and podiatrists to evaluate the feasibility of the protocol. Adapted FOs were developed in 70% of the patients. In these patients, usual care FOs showed a mean 9% reduction in pressure-time integral at forefoot ROIs compared to no-FOs (p=0.01). FO adaptation led to an additional mean 3% reduction in pressure-time integral (p=0.05). The protocol was considered feasible by patients. Podiatrists considered the protocol more useful to achieve individual rather than general treatment goals. A final protocol was proposed. Using in-shoe plantar pressure measurements for adapting foot orthoses for patients with RA leads to a small additional plantar pressure reduction in the forefoot. Further research on the clinical relevance of this outcome is required. Copyright © 2016. Published by Elsevier B.V.
Xie, Peigen; Wang, Yanling; Xu, Xiaoying; Huang, Fei; Pan, Jingru
2015-04-01
The objective of this study was to determine the accuracy of the Pangao PG-800A11 wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the protocol of the British Hypertension Society (BHS). The device evaluations were performed in 85 participants, 33 of whom were included according to the ESH-IP revision 2010 and 52 of whom were included on the basis of the requirements of the BHS protocol. The validation procedure and data analysis followed the protocols precisely. The device achieved an A/A grading for the BHS protocol and passed all phases of the ESH-IP revision 2010 protocol. The mean difference ±SD for the ESH and BHS protocols, respectively, was -0.6±4.5 and -0.8±6.2 mmHg for systolic pressure and 1.2±4.6 and -0.5±5.1 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low, medium, and high-pressure ranges. The Pangao PG-800A11 wrist blood pressure monitor passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol in an adult population.
Sánchez, Manuel; García-de-Lorenzo, Abelardo; Herrero, Eva; Lopez, Teresa; Galvan, Beatriz; Asensio, María; Cachafeiro, Lucia; Casado, Cesar
2013-08-15
The use of urinary output and vital signs to guide initial burn resuscitation may lead to suboptimal resuscitation. Invasive hemodynamic monitoring may result in over-resuscitation. This study aimed to evaluate the results of a goal-directed burn resuscitation protocol that used standard measures of mean arterial pressure (MAP) and urine output, plus transpulmonary thermodilution (TPTD) and lactate levels to adjust fluid therapy to achieve a minimum level of preload to allow for sufficient vital organ perfusion. We conducted a three-year prospective cohort study of 132 consecutive critically burned patients. These patients underwent resuscitation guided by MAP (>65 mmHg), urinary output (0.5 to 1 ml/kg), TPTD and lactate levels. Fluid therapy was adjusted to achieve a cardiac index (CI) >2.5 L/minute/m² and an intrathoracic blood volume index (ITBVI) >600 ml/m2, and to optimize lactate levels. Statistical analysis was performed using mixed models. We also used Pearson or Spearman methods and the Mann-Whitney U-test. A total of 98 men and 34 women (mean age, 48 ± 18 years) was studied. The mean total body surface area (TBSA) burned was 35% ± 22%. During the early resuscitation phase, lactate levels were elevated (2.58 ± 2.05 mmol/L) and TPTD showed initial hypovolemia by the CI (2.68 ± 1.06 L/minute/m²) and the ITBVI (709 ± 254 mL/m²). At 24 to 32 hours, the CI and lactic levels were normalized, although the ITBVI remained below the normal range (744 ± 276 ml/m²). The mean fluid rate required to achieve protocol targets in the first 8 hours was 4.05 ml/kg/TBSA burned, which slightly increased in the next 16 hours. Patients with a urine output greater than or less than 0.5 ml/kg/hour did not show differences in heart rate, mean arterial pressure, CI, ITBVI or lactate levels. Initial hypovolemia may be detected by TPTD monitoring during the early resuscitation phase. This hypovolemia might not be reflected by blood pressure and hourly urine output. An adequate CI and tissue perfusion can be achieved with below-normal levels of preload. Early resuscitation guided by lactate levels and below-normal preload volume targets appears safe and avoids unnecessary fluid input.
Aggarwal, Neil R; Brower, Roy G; Hager, David N; Thompson, B Taylor; Netzer, Giora; Shanholtz, Carl; Lagakos, Adrian; Checkley, William
2018-04-01
High fractions of inspired oxygen may augment lung damage to exacerbate lung injury in patients with acute respiratory distress syndrome. Participants enrolled in Acute Respiratory Distress Syndrome Network trials had a goal partial pressure of oxygen in arterial blood range of 55-80 mm Hg, yet the effect of oxygen exposure above this arterial oxygen tension range on clinical outcomes is unknown. We sought to determine if oxygen exposure that resulted in a partial pressure of oxygen in arterial blood above goal (> 80 mm Hg) was associated with worse outcomes in patients with acute respiratory distress syndrome. Longitudinal analysis of data collected in these trials. Ten clinical trials conducted at Acute Respiratory Distress Syndrome Network hospitals between 1996 and 2013. Critically ill patients with acute respiratory distress syndrome. None. We defined above goal oxygen exposure as the difference between the fraction of inspired oxygen and 0.5 whenever the fraction of inspired oxygen was above 0.5 and when the partial pressure of oxygen in arterial blood was above 80 mm Hg. We then summed above goal oxygen exposures in the first five days to calculate a cumulative above goal oxygen exposure. We determined the effect of a cumulative 5-day above goal oxygen exposure on mortality prior to discharge home at 90 days. Among 2,994 participants (mean age, 51.3 yr; 54% male) with a study-entry partial pressure of oxygen in arterial blood/fraction of inspired oxygen that met acute respiratory distress syndrome criteria, average cumulative above goal oxygen exposure was 0.24 fraction of inspired oxygen-days (interquartile range, 0-0.38). Participants with above goal oxygen exposure were more likely to die (adjusted interquartile range odds ratio, 1.20; 95% CI, 1.11-1.31) and have lower ventilator-free days (adjusted interquartile range mean difference of -0.83; 95% CI, -1.18 to -0.48) and lower hospital-free days (adjusted interquartile range mean difference of -1.38; 95% CI, -2.09 to -0.68). We observed a dose-response relationship between the cumulative above goal oxygen exposure and worsened clinical outcomes for participants with mild, moderate, or severe acute respiratory distress syndrome, suggesting that the observed relationship is not primarily influenced by severity of illness. Oxygen exposure resulting in arterial oxygen tensions above the protocol goal occurred frequently and was associated with worse clinical outcomes at all levels of acute respiratory distress syndrome severity.
Jacobs, David R; Sluik, Diewertje; Rokling-Andersen, Merethe H; Anderssen, Sigmund A; Drevon, Christian A
2009-02-01
We hypothesized that favorable changes in dietary patterns would lead to a reduction in body size and an improvement in metabolic status. The objective was to study changes in diet patterns relative to changes in body size, blood pressure, and circulating concentrations of lipids, glucose, insulin, adiponectin, and other cytokines in the context of a 1-y randomized intervention study. For 1 y, 187 men aged 45 +/- 2 y, approximately 50% of whom met the criteria of the metabolic syndrome, were randomly assigned to a diet protocol (n = 45), an exercise protocol (n = 48), a protocol of diet plus exercise (n = 58), or a control protocol (n = 36). A previously defined a priori diet score was created by summing tertile rankings of 35 food group variables; a higher score generally reflected recommended dietary changes in the trial (mean +/- SD at baseline: 31 +/- 6.5; range: 15-47). Over the study year, the diet score increased by approximately 2 +/- 5.5 in both diet groups, with a decrease of an equivalent amount in the exercise and control groups. The weight change was -3.5 +/- 0.6 kg/10-point change in diet score (P < 0.0001), similarly within each intervention group, independently of the change in energy intake or baseline age and smoking status. Weight change was attenuated but remained significant after adjustment for intervention group and percentage body fat. Subjects with an increased diet score had more favorable changes in other body size variables, systolic blood pressure, and blood lipid, glucose, insulin, and adiponectin concentrations. Change in diet score was unrelated to resistin and several cytokines. The change toward a more favorable diet pattern was associated with improved body size and metabolic profile.
Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling
2017-02-01
The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.
Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H
2014-03-01
The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.
Chen, Liang; Li, Jiyu; Wen, Jing; Guo, Changfeng; Zhang, Jingying; Yu, Zhen
2018-02-01
This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Pangao PG-800B26 for home blood pressure monitoring according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. Systolic and diastolic blood pressures were measured sequentially in 33 and 85 adults, respectively, on the basis of the ESH-IP and BHS protocols using a mercury sphygmomanometer (two observers) and the device (one supervisor). The procedures and analysis methods of the protocols were followed precisely. The device fulfilled the criteria of the ESH-IP, with device-observer differences of 1.01±5.16 and -0.58±4.17 mmHg for systolic and diastolic blood pressure, respectively. Furthermore, the A/A grade of the BHS protocol was also achieved for overall grading and for the three pressure levels, with average differences of 0.85±6.35 and -0.15±5.65 mmHg for systolic and diastolic blood pressure, respectively, which also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800B26 fulfilled the criteria of the ESH-IP 2010 and achieved the A/A grade of the BHS protocol, and hence can be recommended for home use in adults.
Extra-Vehicular Activity (EVA) glove evaluation test protocol
NASA Technical Reports Server (NTRS)
Hinman-Sweeney, E. M.
1994-01-01
One of the most critical components of a space suit is the gloves, yet gloves have traditionally presented significant design challenges. With continued efforts at glove development, a method for evaluating glove performance is needed. This paper presents a pressure-glove evaluation protocol. A description of this evaluation protocol, and its development is provided. The protocol allows comparison of one glove design to another, or any one design to bare-handed performance. Gloves for higher pressure suits may be evaluated at current and future design pressures to drive out differences in performance due to pressure effects. Using this protocol, gloves may be evaluated during design to drive out design problems and determine areas for improvement, or fully mature designs may be evaluated with respect to mission requirements. Several different test configurations are presented to handle these cases. This protocol was run on a prototype glove. The prototype was evaluated at two operating pressures and in the unpressurized state, with results compared to bare-handed performance. Results and analysis from this test series are provided, as is a description of the configuration used for this test.
2013-01-01
Background The excess burden of hypertension among blacks has been a prominent feature of the heath disparities literature, and many scientists presume it to be a stable and inevitable phenomenon. The underlying causes of this disparity can only be disentangled in a setting in which the population does not experience racial stratification of socioeconomic opportunities. While such conditions of racial equality remain uncommon, they may be approximated in Cuba, a country with a persistent policy of social inclusion over the last 5 decades. Methods We report on a 2010–2011 stratified probability sample of those aged 15–74 years from the urban population of Cienfuegos in central Cuba. A total of 1496 adults (880 women and 616 men) were recruited and assessed for blood pressure and anthropometrics according to standardized protocols, as well as medication use, educational attainment and observed skin tone (dichotomized into “black” and “white”). Weighted tabular and regression analyses were conducted to estimate adjusted prevalences of hypertension (> 140/90 mmHg) and adjusted prevalence odds ratios for contrasts between the two skin color groups. Results Mean pressures were higher for men than for women, but overall did not differ importantly between racial groups. About half of all diagnosed hypertensive men were on medication, a proportion that did not vary by racial group. For women, however, adjusted prevalence was somewhat higher among blacks, and treatment and control rates were also somewhat advantaged for white women. Conclusions Overall, skin color was unrelated to mean blood pressure or hypertensive status in this population, although among women specifically some racial advantage appears evident in adjusted prevalence and control, and should be investigated further. The overall null result suggests that Cuba may exemplify the social conditions in which racial excess in hypertension, characteristic of much of the western world, is not a necessary reality. PMID:23433343
Zhao, Hairong; Qiao, Weichang; Zhang, Rui; Cui, Peng; Hou, Fanglin; Zhang, Wenli
2018-02-01
The aim of this study was to validate the PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. A total of 33 participants were initially included on the basis of the ESH-IP, followed by examination of 85 participants according to the BHS protocol. The procedures and analysis methods of the protocols were followed precisely with left arm/wrist sequential measurements by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The device passed the ESH-IP with an average difference of 1.45±6.46 mmHg for systolic blood pressure and 1.25±5.10 mmHg for diastolic blood pressure. Furthermore, the A/A grade of the BHS protocol was achieved with an average difference of 1.84±6.94 mmHg for systolic blood pressure and 1.15±6.49 mmHg for diastolic blood pressure, and thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800A36 passed the requirements of the ESH-IP revision 2010 and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.
Optimization of stent implantation using a high pressure inflation protocol.
Vallurupalli, Srikanth; Bahia, Amit; Ruiz-Rodriguez, Ernesto; Ahmed, Zubair; Hakeem, Abdul; Uretsky, Barry F
2016-01-01
High-pressure inflation is the universal standard for stent deployment but a specific protocol for its use is lacking. We developed a standardized "pressure optimization protocol" (POP) using time to inflation pressure stability as an endpoint for determining the required duration of stent inflation. The primary study purpose was to determine the stent inflation time (IT) in a large patient cohort using the standardized inflation protocol, to correlate various patient and lesion characteristics with IT, and ascertain in an in vitro study the time for pressure accommodation within an inflation system. Six hundred fifteen stent implants in 435 patients were studied. Multivariate analysis was performed to determine predictors of longer ITs. In an in vitro study, various stents and balloons were inflated in air to determine the pressure accommodation time of the inflation system. The mean stent IT was 104 ± 41 sec (range 30-380 sec). Stent length was the only predictor of prolonged stent inflation. The "accommodation time" in vitro of the stent inflation system itself was 33 ± 24 sec. The protocol was safe requiring premature inflation termination in <3% of stent implants. No serious adverse events occurred. Achieving stable inflation pressure requires on average over 100 sec and may require several minutes in individual cases. Stent length increases IT. These results suggest that the widespread practice of rapid inflation/deflation may not be sufficient to fully expand the stent and that the use of a pressure stability protocol will allow for safe, predictable, and more complete stent deployment. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Validation protocols for blood pressure-measuring devices: status quo and development needs.
Beime, Beate; Deutsch, Cornelia; Gomez, Timothy; Zwingers, Thomas; Mengden, Thomas; Bramlage, Peter
2016-02-01
Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy of blood pressure monitoring devices have been developed, including protocols by the Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League (Prüfsiegelprotokoll), and the International Protocol of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. In the past, most of the protocols have been reviewed and modified because of experiences gained during the validation studies carried out. However, each shows distinct differences, that is number and characteristics of patients required, blood pressure ranges, and the length of the validation procedure, which may result in unique advantages and/or limitations associated with their use. The continued standardization and evolution of these guidelines is essential to ensure the efficacy of blood pressure-measuring devices marketed for clinical and home use. Here, we aimed to compare four currently used validation protocols and to initiate a discussion on potential future improvements.
Advani, Aneel; Jones, Neil; Shahar, Yuval; Goldstein, Mary K; Musen, Mark A
2004-01-01
We develop a method and algorithm for deciding the optimal approach to creating quality-auditing protocols for guideline-based clinical performance measures. An important element of the audit protocol design problem is deciding which guide-line elements to audit. Specifically, the problem is how and when to aggregate individual patient case-specific guideline elements into population-based quality measures. The key statistical issue involved is the trade-off between increased reliability with more general population-based quality measures versus increased validity from individually case-adjusted but more restricted measures done at a greater audit cost. Our intelligent algorithm for auditing protocol design is based on hierarchically modeling incrementally case-adjusted quality constraints. We select quality constraints to measure using an optimization criterion based on statistical generalizability coefficients. We present results of the approach from a deployed decision support system for a hypertension guideline.
Nakahara, Takehiro; Jinzaki, Masahiro; Niwamae, Nogiku; Saito, Yuuichirou; Arai, Masashi; Tsushima, Yoshito; Kuribayashi, Sachio; Kurabayashi, Masahiko
2014-01-01
Despite the improvement of cardiac CT, right heart visualization remains challenging. We herein describe a new method, called the time-adjusted gradual replacement injection protocol. The aim of this study was to compare this protocol with the split-bolus injection protocol. Fifty-two patients who had undergone dual-source cardiac CT were retrospectively recruited. Twenty-six patients were injected by using the split-bolus injection protocol, and 26 patients were injected by using the time-adjusted gradual replacement injection protocol. For this method, we injected contrast medium for 10 seconds at a flow rate of 0.07 × body weight mL/s, then gradually replaced the contrast material with saline until 2 seconds before finishing the scans. The CT attenuation was measured in 4 chambers, the aorta, and the coronary arteries. The visualization of the anatomic structures and the occurrence and severity of streak artifacts were scored for the cardiac structures in the heart. For the analyses, either Welch t-test or Student t-test was performed. In the right heart, the CT values and visualization scores were significantly higher in the time-adjusted replacement injection group than in the split-bolus injection group, whereas the artifact scores were comparable between the 2 groups. The CT values, visualization scores, and artifact scores of the left heart were not significantly different between the 2 groups. In this study, the time-adjusted gradual replacement injection protocol provided excellent attenuation for visualization of the right heart. This method may help to accurately evaluate the right cardiac anatomy and thereby identify any potential diseases. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Bapodra, Priya; Cracknell, Jonathan; Wolfe, Barbara A
2014-03-01
Three adult and two subadult greater one-horned rhinoceroses (Rhinoceros unicornis) were sedated a total of nine times using two different intramuscular sedative combinations in order to compare the effectiveness of these combinations in inducing consistent standing sedation in this species. The sedation protocols compared were butorphanol tartrate (50-60 mg) and detomidine hydrochloride (20-30 mg; BD) versus butorphanol tartrate (80-120 mg) and azaperone (80-120 mg; BA). Specific doses were adjusted according to age and sex class, and based on previous experience. Parameters compared included time to achieve defined levels of sedation, time to recovery following antagonism, physiological parameters including heart rate, respiratory rate, indirect arterial blood pressure, and venous blood gas values. A hydraulic restraint chute was utilized to mechanically restrain animals during the procedures, and blood collection and ophthalmic examinations were conducted on all animals. Both protocols resulted in standing sedation for > or = 22.3 +/- 2.9 min or until antagonists were administered. The BD protocol resulted in deeper and more consistent sedation, compared to the BA protocol. Naltrexone hydrochloride (250-300 mg) and tolazoline hydrochloride (1,500-2,000 mg) were administered intramuscularly to antagonize protocol BD, whereas naltrexone alone (200-500 mg) was used to antagonize BA. Time to full antagonism, defined as normal mentation and ambulation following administration of antagonists, was prolonged in the BD protocol (132.3 +/- 17.2 min) compared with the BA protocol (7.5 +/- 2.5 min). Venous blood gas analysis did not reveal any significant blood gas deviations during sedation when compared with either conscious equine or white rhinoceros (Ceratotherium simum) venous reference ranges. In summary, both combinations resulted in adequate standing sedation for minimally invasive procedures, although BD resulted in more profound and consistent sedation.
Smit, C A J; Haverkamp, G L G; de Groot, S; Stolwijk-Swuste, J M; Janssen, T W J
2012-08-01
Ten participants underwent two electrical stimulation (ES) protocols applied using a custom-made electrode garment with built-in electrodes. Interface pressure was measured using a force-sensitive area. In one protocol, both the gluteal and hamstring (g+h) muscles were activated, in the other gluteal (g) muscles only. To study and compare the effects of electrically induced activation of g+h muscles versus g muscles only on sitting pressure distribution in individuals with a spinal cord injury (SCI). Ischial tuberosities interface pressure (ITs pressure) and pressure gradient. In all participants, both protocols of g and g+h ES-induced activation caused a significant decrease in IT pressure. IT pressure after g+h muscles activation was reduced significantly by 34.5% compared with rest pressure, whereas a significant reduction of 10.2% after activation of g muscles only was found. Pressure gradient reduced significantly only after stimulation of g+h muscles (49.3%). g+h muscles activation showed a decrease in pressure relief (Δ IT) over time compared with g muscles only. Both protocols of surface ES-induced of g and g+h activation gave pressure relief from the ITs. Activation of both g+h muscles in SCI resulted in better IT pressure reduction in sitting individuals with a SCI than activation of g muscles only. ES might be a promising method in preventing pressure ulcers (PUs) on the ITs in people with SCI. Further research needs to show which pressure reduction is sufficient in preventing PUs.
Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production.
Williams, Monique; Talbot, Prue
2011-12-01
This study investigated the performance of electronic cigarettes (e-cigarettes), compared different models within a brand, compared identical copies of the same model within a brand, and examined performance using different protocols. Airflow rate required to generate aerosol, pressure drop across e-cigarettes, and aerosol density were examined using three different protocols. First 10 puff protocol: The airflow rate required to produce aerosol and aerosol density varied among brands, while pressure drop varied among brands and between the same model within a brand. Total air hole area correlated with pressure drop for some brands. Smoke-out protocol: E-cigarettes within a brand generally performed similarly when puffed to exhaustion; however, there was considerable variation between brands in pressure drop, airflow rate required to produce aerosol, and the total number of puffs produced. With this protocol, aerosol density varied significantly between puffs and gradually declined. CONSECUTIVE TRIAL PROTOCOL: Two copies of one model were subjected to 11 puffs in three consecutive trials with breaks between trials. One copy performed similarly in each trial, while the second copy of the same model produced little aerosol during the third trial. The different performance properties of the two units were attributed to the atomizers. There was significant variability between and within brands in the airflow rate required to produce aerosol, pressure drop, length of time cartridges lasted, and production of aerosol. Variation in performance properties within brands suggests a need for better quality control during e-cigarette manufacture.
de Rooij, Susanne R; Costello, Paula M; Veenendaal, Marjolein V E; Lillycrop, Karen A; Gluckman, Peter D; Hanson, Mark A; Painter, Rebecca C; Roseboom, Tessa J
2012-06-01
Glucocorticoids are the key regulators of the biological stress response and act by binding to glucocorticoid receptors (GR). Expression of GR is altered by DNA methylation. Methylation patterns in GR promoters have been shown to be highly variable between individuals, but little is known about the functional consequences of this variation for the acute stress response. The present study investigated associations between methylation status of the GR 1-C promoter and cortisol, cardiovascular and perceived stress responses to a psychosocial stress protocol in a large healthy adult population. A total of 725 overall healthy men and women, aged 55-60 years, participated in a standardized psychosocial stress protocol consisting of three different stressors. At different stages during the stress protocol, salivary cortisol levels, continuous blood pressure and heart rate (HR) levels as well as perceived stress were measured. Stress reactivity was calculated as the increase between basal and peak measurements. Methylation status of the GR 1-C promoter was assessed in DNA isolated from peripheral blood samples using a methylation sensitive PCR assay for 675 of the 725 participants. A decrease in methylation of the GR 1-C promoter was associated with a decrease in stress reactivity as indicated by lower cortisol and lower HR reactivity. A 1% decrease in GR 1-C methylation corresponded with a cortisol decrease by 0.14% (95% CI: 0.03-0.25, p=0.02) and an HR decrease by 0.10 bpm (0.03-0.16, p=0.003). Adjusting for sex, lifestyle and education largely abolished these associations. A decrease in methylation of the GR 1-C promoter was also associated with an increase in stress perception as indicated by higher perceived stress (0.03 points [0.00-0.06, p=0.05]), lower perceived performance (-0.03 points [-0.05 to -0.01], p=0.02), and lower perceived control (-0.03 points [-0.05 to 0.00], p=0.04). After adjusting for sex and educational level the associations were no longer statistically significant. GR 1-C methylation status was not associated with blood pressure responses to the stress protocol. Although effects were small, variation in methylation status in the GR 1-C promoter was associated with physical and perceived acute stress responses. Interestingly, these associations could largely be explained by differences in lifestyle and education. Copyright © 2011 Elsevier Ltd. All rights reserved.
Intermittent pressure decreases human keratinocyte proliferation in vitro.
Nasca, Maria R; Shih, Alan T; West, Dennis P; Martinez, Wanda M; Micali, Giuseppe; Landsman, Adam S
2007-01-01
The aim of this study was to investigate the correlation between pressure changes and keratinocyte proliferation by determining whether keratinocytes exposed to altered mechanical pressures would proliferate at different rates compared to control cells not subjected to pressure changes. Tissue culture flasks of human keratinocytes plated at an approximate density of 15,000 cells/cm(2) undergoing an intermittent cyclic pressure of 362 mm Hg at a frequency of 2.28 or 5.16 cycles/min (0.038 or 0.086 Hz) for 8 h were compared to control flasks grown at ambient room pressure. An in-line pressure transducer was used to monitor and adjust pressure within the cell chambers, using a solenoid valve. A thymidine incorporation assay assessed the amount of cell proliferation in each set of experiments. Differences in proliferation between keratinocytes subjected to cyclic pressure changes and control cells were found to be statistically significant (p < 0.05) in 4 out of 5 proliferation assays. Also, a higher frequency of pressure changes consistently generated a reduced proliferation rate compared to that seen in cells exposed to a lower frequency of pressure changes. These data indicate that keratinocytes undergoing intermittent pressure changes exhibit decreased proliferation rates compared to controls. Furthermore, an increased frequency rate seems to have a greater effect on proliferation than low-frequency rate pressure changes, suggesting that the stress caused by frequently changed pressure may play a greater role in reducing keratinocyte proliferation than the actual magnitude of load applied to the cells. Our results support the current treatment protocol of reducing speed and duration of walking on the site of the wound to promote healing of foot ulcers. (c) 2007 S. Karger AG, Basel.
Cardiovascular studies using the chimpanzee (Pan troglodytes)
NASA Technical Reports Server (NTRS)
Hinds, J. E.; Cothran, L. N.; Hawthorne, E. W.
1977-01-01
Despite the phylogenetic similarities between chimpanzees and man, there exists a paucity of reliable data on normal cardiovascular function and the physiological responses of the system to standard interventions. Totally implanted biotelemetry systems or hardwire analog techniques were used to examine the maximum number of cardiovascular variables which could be simultaneously monitored without significantly altering the system's performance. This was performed in order to acquire base-line data not previously obtained in this species, to determine cardiovascular response to specific forcing functions such as ventricular pacing, drug infusions, and lower body negative pressure. A cardiovascular function profile protocol was developed in order to adjust independently the three major factors which modify ventricular performance, namely, left ventricular performance, left ventricular preload, afterload, and contractility. Cardiac pacing at three levels above the ambient rate was used to adjust end diastolic volume (preload). Three concentrations of angiotensin were infused continuously to evaluate afterload in a stepwide fashion. A continuous infusion of dobutamine was administered to raise the manifest contractile state of the heart.
A randomized trial of protocol-based care for early septic shock.
Yealy, Donald M; Kellum, John A; Huang, David T; Barnato, Amber E; Weissfeld, Lisa A; Pike, Francis; Terndrup, Thomas; Wang, Henry E; Hou, Peter C; LoVecchio, Frank; Filbin, Michael R; Shapiro, Nathan I; Angus, Derek C
2014-05-01
In a single-center study published more than a decade ago involving patients presenting to the emergency department with severe sepsis and septic shock, mortality was markedly lower among those who were treated according to a 6-hour protocol of early goal-directed therapy (EGDT), in which intravenous fluids, vasopressors, inotropes, and blood transfusions were adjusted to reach central hemodynamic targets, than among those receiving usual care. We conducted a trial to determine whether these findings were generalizable and whether all aspects of the protocol were necessary. In 31 emergency departments in the United States, we randomly assigned patients with septic shock to one of three groups for 6 hours of resuscitation: protocol-based EGDT; protocol-based standard therapy that did not require the placement of a central venous catheter, administration of inotropes, or blood transfusions; or usual care. The primary end point was 60-day in-hospital mortality. We tested sequentially whether protocol-based care (EGDT and standard-therapy groups combined) was superior to usual care and whether protocol-based EGDT was superior to protocol-based standard therapy. Secondary outcomes included longer-term mortality and the need for organ support. We enrolled 1341 patients, of whom 439 were randomly assigned to protocol-based EGDT, 446 to protocol-based standard therapy, and 456 to usual care. Resuscitation strategies differed significantly with respect to the monitoring of central venous pressure and oxygen and the use of intravenous fluids, vasopressors, inotropes, and blood transfusions. By 60 days, there were 92 deaths in the protocol-based EGDT group (21.0%), 81 in the protocol-based standard-therapy group (18.2%), and 86 in the usual-care group (18.9%) (relative risk with protocol-based therapy vs. usual care, 1.04; 95% confidence interval [CI], 0.82 to 1.31; P=0.83; relative risk with protocol-based EGDT vs. protocol-based standard therapy, 1.15; 95% CI, 0.88 to 1.51; P=0.31). There were no significant differences in 90-day mortality, 1-year mortality, or the need for organ support. In a multicenter trial conducted in the tertiary care setting, protocol-based resuscitation of patients in whom septic shock was diagnosed in the emergency department did not improve outcomes. (Funded by the National Institute of General Medical Sciences; ProCESS ClinicalTrials.gov number, NCT00510835.).
Challenges in standardization of blood pressure measurement at the population level.
Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari
2015-04-10
Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.
El Feghali, Ramzi N; Topouchian, Jirar A; Pannier, Bruno M; El Assaad, Hiba A; Asmar, Roland G
2007-06-01
A high percentage of hypertensive patients present an arm circumference of over 32 cm; the use of a large cuff is therefore recommended. Validation studies are usually performed in the general population using a standard-size cuff. The aim of this study was to assess the accuracy of the Omron M7 device in a population with an arm circumference ranging from 32 to 42 cm. A validation study was performed according to the International Protocol of the European Society of Hypertension. This protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood-pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood-pressure measurements), making a total number of 33 participants (99 pairs of blood-pressure measurements), on whom the analysis is performed. For each participant, four blood-pressure measurements were performed simultaneously by two trained observers, using mercury sphygmomanometers fitted with a Y tube; the measurements alternated with three by the test device. The difference between the blood-pressure value given by the device and that obtained by the two observers (mean of the two observations) was calculated for each measure. The 99 pairs of blood-pressure differences were classified into three categories (
Manternach, Jeremy N; Clark, Chad; Daugherty, James F
2017-07-01
Researchers have found that semi-occluded vocal tract (SOVT) exercises may increase vocal economy by reducing phonation threshold pressure and effort while increasing or maintaining consistent acoustic output. This research has focused solely on individual singers. Much singing instruction, however, takes place in choral settings. Choral singers may use different resonance strategies or unconsciously adjust their singing based on the ability to hear their own sound in relation to others. Results of studies with individual singers, then, may not be directly applicable to choral settings. The purpose of this investigation was to measure the effect of an SOVT protocol (ie, straw phonation) on acoustic changes of conglomerate, choral sound. This is a quasi-experimental, one-group, pretest-posttest design. Participants in this study constituted an intact SATB choir (soprano, alto, tenor, and bass) (N = 15 singers) who performed from memory two unaccompanied pieces of varied tempos from memory, participated in a 4-minute straw phonation protocol with a small stirring straw, and then sang each piece a second time. The long-term average spectrum results indicated small, statistically significant increases in spectral energy for both pieces in the 0-10 kHz (.32 and .20 dB Sound Pressure Level) and 2-4 kHz regions (.46 and .25 dB SPL). These results, although not likely audible to average hearing humans, seem consistent with the assertion that singers enjoy vocal benefits with consistent or increased vocal output. SOVT exercises, therefore, may be useful as a time-efficient way to evoke more efficient and economical singing during choral warm-up and voice building procedures. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Makhsous, Mohsen; Priebe, Michael; Bankard, James; Rowles, Diana; Zeigler, Mary; Chen, David; Lin, Fang
2007-01-01
Background/Objective: To study the effect on tissue perfusion of relieving interface pressure using standard wheelchair pushups compared with a mechanical automated dynamic pressure relief system. Design: Repeated measures in 2 protocols on 3 groups of subjects. Participants: Twenty individuals with motor-complete paraplegia below T4, 20 with motor-complete tetraplegia, and 20 able-bodied subjects. Methods: Two 1-hour sitting protocols: dynamic protocol, sitting configuration alternated every 10 minutes between a normal sitting configuration and an off-loading configuration; wheelchair pushup protocol, normal sitting configuration with standard wheelchair pushup once every 20 minutes. Main Outcome Measures: Transcutaneous partial pressures of oxygen and carbon dioxide measured from buttock overlying the ischial tuberosity and interface pressure measured at the seat back and buttocks. Perfusion deterioration and recovery times were calculated during changes in interface pressures. Results: In the off-loading configuration, concentrated interface pressure during the normal sitting configuration was significantly diminished, and tissue perfusion was significantly improved. Wheelchair pushups showed complete relief of interface pressure but incomplete recovery of tissue perfusion. Conclusions: Interface pressure analysis does not provide complete information about the effectiveness of pressure relief maneuvers. Measures of tissue perfusion may help establish more effective strategies. Relief achieved by standard wheelchair pushups may not be sufficient to recover tissue perfusion compromised during sitting; alternate maneuvers may be necessary. The dynamic seating system provided effective pressure relief with sustained reduction in interface pressure adequate for complete recovery of tissue perfusion. Differences in perfusion recovery times between subjects with spinal cord injury (SCI) and controls raise questions about the importance of changes in vascular responses to pressure after SCI. PMID:18092567
Shiwa, Yuh; Hachiya, Tsuyoshi; Furukawa, Ryohei; Ohmomo, Hideki; Ono, Kanako; Kudo, Hisaaki; Hata, Jun; Hozawa, Atsushi; Iwasaki, Motoki; Matsuda, Koichi; Minegishi, Naoko; Satoh, Mamoru; Tanno, Kozo; Yamaji, Taiki; Wakai, Kenji; Hitomi, Jiro; Kiyohara, Yutaka; Kubo, Michiaki; Tanaka, Hideo; Tsugane, Shoichiro; Yamamoto, Masayuki; Sobue, Kenji; Shimizu, Atsushi
2016-01-01
Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS) using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03) when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50) when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λadjusted = 1.14) by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12–1.45) and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λadjusted = 1.00–1.17). These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models. PMID:26799745
Shiwa, Yuh; Hachiya, Tsuyoshi; Furukawa, Ryohei; Ohmomo, Hideki; Ono, Kanako; Kudo, Hisaaki; Hata, Jun; Hozawa, Atsushi; Iwasaki, Motoki; Matsuda, Koichi; Minegishi, Naoko; Satoh, Mamoru; Tanno, Kozo; Yamaji, Taiki; Wakai, Kenji; Hitomi, Jiro; Kiyohara, Yutaka; Kubo, Michiaki; Tanaka, Hideo; Tsugane, Shoichiro; Yamamoto, Masayuki; Sobue, Kenji; Shimizu, Atsushi
2016-01-01
Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS) using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03) when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50) when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14) by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45) and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17). These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.
Yeates, Erin M; Molfenter, Sonja M; Steele, Catriona M
2008-01-01
Dysphagia, or difficulty swallowing, often occurs secondary to conditions such as stroke, head injury or progressive disease, many of which increase in frequency with advancing age. Sarcopenia, the gradual loss of muscle bulk and strength, can place older individuals at greater risk for dysphagia. Data are reported for three older participants in a pilot trial of a tongue-pressure training therapy. During the experimental therapy protocol, participants performed isometric strength exercises for the tongue as well as tongue pressure accuracy tasks. Biofeedback was provided using the Iowa Oral Performance Instrument (IOPI), an instrument that measures tongue pressure. Treatment outcome measures show increased isometric tongue strength, improved tongue pressure generation accuracy, improved bolus control on videofluoroscopy, and improved functional dietary intake by mouth. These preliminary results indicate that, for these three adults with dysphagia, tongue-pressure training was beneficial for improving both instrumental and functional aspects of swallowing. The experimental treatment protocol holds promise as a rehabilitative tool for various dysphagia populations.
Topouchian, Jirar A; El Assaad, Mohamed A; Orobinskaia, Ludmila V; El Feghali, Ramzi N; Asmar, Roland G
2006-06-01
Two electronic devices for self-measurement of blood pressure - a brachial monitor, the Omron M6, and a wrist monitor, the Omron R7 - were evaluated in two separate studies according to the International Protocol of the European Society of Hypertension. The International Validation Protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood pressure measurements) making a total number of 33 participants (99 pairs of blood pressure measurements) on whom the final validation is performed. The same methodology recommended by the European Society of Hypertension protocol was applied for both studies. In each study and for each participant, four blood pressure measurements were taken simultaneously by two trained observers using mercury sphygmomanometers alternately with three measurements taken by the tested device. The difference between the blood pressure value given by the device and that obtained by the two observers (mean of the two observers) was calculated for each measure. The 99 pairs of blood pressure differences were classified into three categories (
Elmståhl, Sölve; Widerström, Elisabet
2014-01-01
Introduction Contradictory results have been reported on the relationship between orthostatic hypotension (OH) and mild cognitive impairment (MCI). Objective To study the incidence of MCI and dementia and their relationship to OH and subclinical OH with orthostatic symptoms (orthostatic intolerance). Study design and setting This study used a prospective general population cohort design and was based on data from the Swedish Good Aging in Skåne study (GÅS-SNAC), they were studied 6 years after baseline of the present study, with the same study protocol at baseline and at follow-up. The study sample comprised 1,480 randomly invited subjects aged 60 to 93 years, and had a participation rate of 82% at follow-up. OH test included assessment of blood pressure and symptoms of OH. Results The 6-year incidence of MCI was 8%, increasing from 12.1 to 40.5 per 1,000 person-years for men and 6.9 to 16.9 per 1,000 person-years for women aged 60 to >80 years. The corresponding 6-year incidence of dementia was 8%. Orthostatic intolerance during uprising was related to risk for MCI at follow-up (odds ratio [OR] =1.84 [1.20–2.80][95% CI]), adjusted for age and education independently of blood pressure during testing. After stratification for hypertension (HT), the corresponding age-adjusted OR for MCI in the non-HT group was 1.71 (1.10–2.31) and 1.76 (1.11–2.13) in the HT group. Among controls, the proportion of those with OH was 16%; those with MCI 24%; and those with dementia 31% (age-adjusted OR 1.93 [1.19–3.14]). Conclusion Not only OH, but also symptoms of OH, seem to be a risk factor for cognitive decline and should be considered in the management of blood pressure among the elderly population. PMID:25429211
Kacmarek, Robert M; Villar, Jesús; Sulemanji, Demet; Montiel, Raquel; Ferrando, Carlos; Blanco, Jesús; Koh, Younsuck; Soler, Juan Alfonso; Martínez, Domingo; Hernández, Marianela; Tucci, Mauro; Borges, Joao Batista; Lubillo, Santiago; Santos, Arnoldo; Araujo, Juan B; Amato, Marcelo B P; Suárez-Sipmann, Fernando
2016-01-01
The open lung approach is a mechanical ventilation strategy involving lung recruitment and a decremental positive end-expiratory pressure trial. We compared the Acute Respiratory Distress Syndrome network protocol using low levels of positive end-expiratory pressure with open lung approach resulting in moderate to high levels of positive end-expiratory pressure for the management of established moderate/severe acute respiratory distress syndrome. A prospective, multicenter, pilot, randomized controlled trial. A network of 20 multidisciplinary ICUs. Patients meeting the American-European Consensus Conference definition for acute respiratory distress syndrome were considered for the study. At 12-36 hours after acute respiratory distress syndrome onset, patients were assessed under standardized ventilator settings (FIO2≥0.5, positive end-expiratory pressure ≥10 cm H2O). If Pao2/FIO2 ratio remained less than or equal to 200 mm Hg, patients were randomized to open lung approach or Acute Respiratory Distress Syndrome network protocol. All patients were ventilated with a tidal volume of 4 to 8 ml/kg predicted body weight. From 1,874 screened patients with acute respiratory distress syndrome, 200 were randomized: 99 to open lung approach and 101 to Acute Respiratory Distress Syndrome network protocol. Main outcome measures were 60-day and ICU mortalities, and ventilator-free days. Mortality at day-60 (29% open lung approach vs. 33% Acute Respiratory Distress Syndrome Network protocol, p = 0.18, log rank test), ICU mortality (25% open lung approach vs. 30% Acute Respiratory Distress Syndrome network protocol, p = 0.53 Fisher's exact test), and ventilator-free days (8 [0-20] open lung approach vs. 7 [0-20] d Acute Respiratory Distress Syndrome network protocol, p = 0.53 Wilcoxon rank test) were not significantly different. Airway driving pressure (plateau pressure - positive end-expiratory pressure) and PaO2/FIO2 improved significantly at 24, 48 and 72 hours in patients in open lung approach compared with patients in Acute Respiratory Distress Syndrome network protocol. Barotrauma rate was similar in both groups. In patients with established acute respiratory distress syndrome, open lung approach improved oxygenation and driving pressure, without detrimental effects on mortality, ventilator-free days, or barotrauma. This pilot study supports the need for a large, multicenter trial using recruitment maneuvers and a decremental positive end-expiratory pressure trial in persistent acute respiratory distress syndrome.
Bing, Sen; Chen, Kang; Hou, Hong; Zhang, Weijuan; Li, Linyi; Wei, Jiao; Shu, Chang; Wan, Yi
2016-04-01
This study aimed to determine the accuracy of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors according to the European Society of Hypertension International Protocol revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols. The devices were assessed on 33 participants according to the European Society of Hypertension requirements and were then tested on 85 participants according to the ANSI/AAMI/ISO 81060-2:2013 criteria. Procedures and data analysis were carried out following protocol guidelines precisely. The Microlife BP A200 Comfort and W2 Slim devices passed the criteria of the European Society of Hypertension International Protocol revision 2010 for both systolic blood pressure and diastolic blood pressure. The devices also fulfilled the ANSI/AAMI/ISO 81060-2:2013 criteria, with mean differences of SBP and DPB between the devices and observers of 0.38±5.12 and 0.28±4.29 mmHg for the BP A200 Comfort and 1.01±6.80 and 0.34±5.62 mmHg for the W2 Slim, respectively. The Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors fulfilled the European Society of Hypertension revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols, and can be recommended for self-measurement in the general population.
Remotely Adjustable Hydraulic Pump
NASA Technical Reports Server (NTRS)
Kouns, H. H.; Gardner, L. D.
1987-01-01
Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.
Liu, Bian; Lau, Kui Kai; Li, Linxin; Lovelock, Caroline; Liu, Ming; Kuker, Wilhelm; Rothwell, Peter M
2018-04-01
It has been hypothesized that cerebral small vessel disease (SVD) and chronic renal impairment may be part of a multisystem small-vessel disorder, but their association may simply be as a result of shared risk factors (eg, hypertension) rather than to a systemic susceptibility to premature SVD. However, most previous studies were hospital based, most had inadequate adjustment for hypertension, many were confined to patients with lacunar stroke, and none stratified by age. In a population-based study of transient ischemic attack and ischemic stroke (OXVASC [Oxford Vascular Study]), we evaluated the magnetic resonance imaging markers of cerebral SVD, including lacunes, white matter hyperintensities, cerebral microbleeds, and enlarged perivascular space. We studied the age-specific associations of renal impairment (estimated glomerular filtration rate <60 mL/min per 1.73 m 2 ) and total SVD burden (total SVD score) adjusting for age, sex, vascular risk factors, and premorbid blood pressure (mean blood pressure during 15 years preevent). Of 1080 consecutive patients, 1028 (95.2%) had complete magnetic resonance imaging protocol and creatinine measured at baseline. Renal impairment was associated with total SVD score (odds ratio [OR], 2.16; 95% confidence interval [CI], 1.69-2.75; P <0.001), but only at age <60 years (<60 years: OR, 3.97; 95% CI, 1.69-9.32; P =0.002; 60-79 years: OR, 1.01; 95% CI, 0.72-1.41; P =0.963; ≥80 years: OR, 0.95; 95% CI, 0.59-1.54; P =0.832). The overall association of renal impairment and total SVD score was also attenuated after adjustment for age, sex, history of hypertension, diabetes mellitus, and premorbid average systolic blood pressure (adjusted OR, 0.76; 95% CI, 0.56-1.02; P =0.067), but the independent association of renal impairment and total SVD score at age <60 years was maintained (adjusted OR, 3.11; 95% CI, 1.21-7.98; P =0.018). Associations of renal impairment and SVD were consistent for each SVD marker at age <60 years but were strongest for cerebral microbleeds (OR, 5.84; 95% CI, 1.45-23.53; P =0.013) and moderate-severe periventricular white matter hyperintensities (OR, 6.28; 95% CI, 1.54-25.63; P =0.010). The association of renal impairment and cerebral SVD was attenuated with adjustment for shared risk factors at older ages, but remained at younger ages, consistent with a shared susceptibility to premature disease. © 2018 The Authors.
Berman, D Wayne
2011-08-01
Given that new protocols for assessing asbestos-related cancer risk have recently been published, questions arise concerning how they compare to the "IRIS" protocol currently used by regulators. The newest protocols incorporate findings from 20 additional years of literature. Thus, differences between the IRIS and newer Berman and Crump protocols are examined to evaluate whether these protocols can be reconciled. Risks estimated by applying these protocols to real exposure data from both laboratory and field studies are also compared to assess the relative health protectiveness of each protocol. The reliability of risks estimated using the two protocols are compared by evaluating the degree with which each potentially reproduces the known epidemiology study risks. Results indicate that the IRIS and Berman and Crump protocols can be reconciled; while environment-specific variation within fiber type is apparently due primarily to size effects (not addressed by IRIS), the 10-fold (average) difference between amphibole asbestos risks estimated using each protocol is attributable to an arbitrary selection of the lowest of available mesothelioma potency factors in the IRIS protocol. Thus, the IRIS protocol may substantially underestimate risk when exposure is primarily to amphibole asbestos. Moreover, while the Berman and Crump protocol is more reliable than the IRIS protocol overall (especially for predicting amphibole risk), evidence is presented suggesting a new fiber-size-related adjustment to the Berman and Crump protocol may ultimately succeed in reconciling the entire epidemiology database. However, additional data need to be developed before the performance of the adjusted protocol can be fully validated. © 2011 Society for Risk Analysis.
Bing, Sen; Zhang, Cunhai; Wang, Liping; Li, Linyi; Wan, Yi
2014-12-01
The study aimed to determine the accuracy of the fully automated oscillometric upper-arm blood pressure (BP) monitor Pangao PG-800B11 according to the European Society of Hypertension-International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocol 1993. Data from 33 participants were initially examined according to the ESH-IP revision 2010. Furthermore, 52 participants were then enrolled to fulfill the BHS protocol requirements. In all participants, sequential left arm measurements were performed by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The protocols' requirements were followed precisely. The device passed all parts of the ESH protocol for systolic blood pressure (SBP) and diastolic blood pressure (DBP) and was graded A according to the criteria of the BHS protocol for both SBP and DBP. The A/A grade was achieved in low (<130/80 mmHg), medium (130-160/80-100 mmHg), and high (>160/100 mmHg) BP categories. The mean BP difference between PG-800B11 and observers in the 85 participants was -0.6±5.0 mmHg for SBP and -0.6±4.5 mmHg for DBP; thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation (AAMI). The Pangao PG-800B11 passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol across a wide range of BPs.
SU-E-I-68: Practical Considerations On Implementation of the Image Gently Pediatric CT Protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Adams, C; Lumby, C
Purpose: One limitation associated with the Image Gently pediatric CT protocols is practical implementation of the recommended manual techniques. Inconsistency as a result of different practice is a possibility among technologist. An additional concern is the added risk of data error that would result in over or underexposure. The Automatic Exposure Control (AEC) features automatically reduce radiation for children. However, they do not work efficiently for the patients of very small size and relative large size. This study aims to implement the Image Gently pediatric CT protocols in the practical setting while maintaining the use of AEC features for pediatricmore » patients of varying size. Methods: Anthropomorphological abdomen phantoms were scanned in a CT scanner using the Image Gently pediatric protocols, the AEC technique with a fixed adult baseline, and automatic protocols with various baselines. The baselines were adjusted corresponding to patient age, weight and posterioranterior thickness to match the Image Gently pediatric CT manual techniques. CTDIvol was recorded for each examination. Image noise was measured and recorded for image quality comparison. Clinical images were evaluated by pediatric radiologists. Results: By adjusting vendor default baselines used in the automatic techniques, radiation dose and image quality can match those of the Image Gently manual techniques. In practice, this can be achieved by dividing pediatric patients into three major groups for technologist reference: infant, small child, and large child. Further division can be done but will increase the number of CT protocols. For each group, AEC can efficiently adjust acquisition techniques for children. This implementation significantly overcomes the limitation of the Image Gently manual techniques. Conclusion: Considering the effectiveness in clinical practice, Image Gently Pediatric CT protocols can be implemented in accordance with AEC techniques, with adjusted baselines, to achieve the goal of providing the most appropriate radiation dose for pediatric patients of varying sizes.« less
Mamon, J; Green, L; Levine, D M; Gibson, G; Gurley, H T
1987-08-01
This study describes the development and testing of a high blood pressure protocol for use in emergency departments (ED) to enhance detection of those patients appropriate for subsequent referral. The protocol involves two serial blood pressure measurements and a patient interview to determine: 1) previous history of high blood pressure (HBP), 2) treatment in past year for HBP, and 3) usual source of medical care. The accuracy of patient reporting was validated by comparison with the patients' hospital record (reflecting outpatient and inpatient visits). Results indicate that these self-reports have high levels of sensitivity (range 90-100%) and specificity (range 79-96%). Use of the additional patient information increased the sensitivity of the screening protocol in identifying when and where a patient should be referred. Use of this methodology indicates that the protocol is a simple and effective method for HBP screening. The findings also suggest that the ED is an ideal site for screening the "hard-to-reach" hypertensive population.
The costs and cost-effectiveness of an integrated sepsis treatment protocol.
Talmor, Daniel; Greenberg, Dan; Howell, Michael D; Lisbon, Alan; Novack, Victor; Shapiro, Nathan
2008-04-01
Sepsis is associated with high mortality and treatment costs. International guidelines recommend the implementation of integrated sepsis protocols; however, the true cost and cost-effectiveness of these are unknown. To assess the cost-effectiveness of an integrated sepsis protocol, as compared with conventional care. Prospective cohort study of consecutive patients presenting with septic shock and enrolled in the institution's integrated sepsis protocol. Clinical and economic outcomes were compared with a historical control cohort. Beth Israel Deaconess Medical Center. Overall, 79 patients presenting to the emergency department with septic shock in the treatment cohort and 51 patients in the control group. An integrated sepsis treatment protocol incorporating empirical antibiotics, early goal-directed therapy, intensive insulin therapy, lung-protective ventilation, and consideration for drotrecogin alfa and steroid therapy. In-hospital treatment costs were collected using the hospital's detailed accounting system. The cost-effectiveness analysis was performed from the perspective of the healthcare system using a lifetime horizon. The primary end point for the cost-effectiveness analysis was the incremental cost per quality-adjusted life year gained. Mortality in the treatment group was 20.3% vs. 29.4% in the control group (p = .23). Implementing an integrated sepsis protocol resulted in a mean increase in cost of approximately $8,800 per patient, largely driven by increased intensive care unit length of stay. Life expectancy and quality-adjusted life years were higher in the treatment group; 0.78 and 0.54, respectively. The protocol was associated with an incremental cost of $11,274 per life-year saved and a cost of $16,309 per quality-adjusted life year gained. In patients with septic shock, an integrated sepsis protocol, although not cost-saving, appears to be cost-effective and compares very favorably to other commonly delivered acute care interventions.
Costa, Deena Kelly; Wallace, David J; Kahn, Jeremy M
2015-11-01
Daytime intensivist physician staffing is associated with improved outcomes in the ICU. However, it is unclear whether this association persists in the era of interprofessional, protocol-directed critical care. We sought to reexamine the association between daytime intensivist physician staffing and ICU mortality and determine if interprofessional rounding and protocols for mechanical ventilation in part mediate this relationship. Retrospective cohort study of ICUs in the Acute Physiology and Chronic Health Evaluation clinical information system from 2009 to 2010. Forty-nine ICUs in 25 U.S. hospitals. Adults (17 yr and older) admitted to a study ICU. None. We defined high-intensity daytime intensivist staffing as either a mandatory consult or closed ICU model; interprofessional rounds as rounds that included a respiratory therapist, pharmacist, physician and nurse; and protocol use as having protocols for liberation from mechanical ventilation and lung protective mechanical ventilation. Using multivariable logistic regression, we estimated the independent effect of daytime intensivist physician staffing on in-hospital mortality controlling for interprofessional rounds and protocols for mechanical ventilation, as well as other patient and hospital characteristics. Twenty-seven ICUs (55%) reported high-intensity daytime physician staffing, 42 ICUs (85%) reported daily interprofessional rounds, and 31 (63%) reported having protocols for mechanical ventilation. There was no association between daytime intensivist physician staffing and in-hospital mortality (adjusted odds ratio, 0.86; 95% CI, 0.65-1.14). After adjusting for interprofessional rounds and protocols for mechanical ventilation, the effect of daytime intensivist physician staffing remained nonsignificant (adjusted odds ratio, 0.90; 95% CI, 0.70-1.17). High-intensity daytime physician staffing in the ICU was not significantly associated with lower mortality in a modern cohort. This association was not affected by interprofessional rounds or protocols for mechanical ventilation.
The association between smoking and blood pressure in men: a cross-sectional study.
Li, Guoju; Wang, Hailing; Wang, Ke; Wang, Wenrui; Dong, Fen; Qian, Yonggang; Gong, Haiying; Hui, Chunxia; Xu, Guodong; Li, Yanlong; Pan, Li; Zhang, Biao; Shan, Guangliang
2017-10-10
Cigarette smoking is a known risk factor for cardiovascular disease (CVD), but the association between smoking and blood pressure is unclear. Thus, the current study examined the association between cigarette smoking and blood pressure in men. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and pulse pressure (PP) were examined using digital blood pressure measuring device, and smoking status was determined with China National Health Survey. The ANCOVA showed that the adjusted DBP and MAP were lower in current smokers versus nonsmokers and the adjusted SBP was lower in current smokers versus former smokers (P < 0.05). Additionally, the adjusted PP tend to be decreased steadily as the pack·years increased in current smokers. In a fully adjusted logistic regression model, former smokers had increased ORs (95% CI) of 1.48 (1.01, 2.18) of hypertension and current smokers had not increased ORs (95% CI) of 0.83 (0.61, 1.12), compared with never smokers. The findings revealed that the adjusted blood pressure were lower in current smokers versus nonsmokers and former smokers. No significant dose-dependent effect of current smoking on blood pressure indices except PP was observed. Smoking cessation was significantly associated with an increased risk of hypertension. However, current smoking was not a risk factor of hypertension.
Chen, Wan; Zeng, Zhaolin; Li, Lizhi; Wan, Xiaofen; Wan, Yi
2014-10-01
This study aimed to validate the Pangao PG-800B5 upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. A total of 33 participants, 16 men and 17 women, were included in the device evaluation. The protocol requirements were followed precisely. The mean age of the participants was 56.4±21.0 years (range 22-84 years). The mean systolic blood pressure was 143.6±25.5 mmHg (range 98-188 mmHg), the mean diastolic blood pressure was 85.7±17.2 mmHg (range 49-125 mmHg), and the mean arm circumference was 26.1±2.2 cm (range 23-32 cm). On average, the device overestimated the systolic blood pressure by 0.9±4.2 mmHg and diastolic blood pressure by 0.7±4.5 mmHg. The device passed all requirements, fulfilling the standards of the protocol. Therefore, the Pangao PG-800B5 upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population.
The role of premorbid adjustment in schizophrenia: Focus on cognitive remediation outcome.
Buonocore, Mariachiara; Bosinelli, Francesca; Bechi, Margherita; Spangaro, Marco; Piantanida, Marco; Cocchi, Federica; Bianchi, Laura; Guglielmino, Carmelo; Mastromatteo, Antonella Rita; Cavallaro, Roberto; Bosia, Marta
2018-02-19
Premorbid adjustment has been associated with several outcomes in schizophrenia and has been proposed as an index of cognitive reserve. This study aims to comprehensively analyse the relation between premorbid adjustment and clinical, neurocognitive, socio-cognitive and functional assessments, as well as to investigate the effect of premorbid adjustment on cognitive improvements after a cognitive remediation therapy protocol. Seventy-nine clinically stabilised outpatients with schizophrenia underwent a combined intervention consisting of cognitive remediation therapy added to standard rehabilitation therapy. All patients were assessed at baseline for psychopathology, premorbid adjustment, intellectual level, cognition and functioning. Cognitive evaluations were also repeated after the intervention. At baseline, significant correlations were observed between premorbid adjustment and working memory. The global cognitive improvement after treatment was significantly predicted by age and premorbid adjustment. This study confirms the association between premorbid adjustment and cognitive impairment and is the first to highlight the possible role of premorbid adjustment on the capacity to recover from cognitive deficits through a cognitive remediation therapy protocol. The data suggest that cognitive remediation may be particularly effective for people in the early course and that the assessment of premorbid adjustment could be of value to design individualised interventions.
Yeates, Erin M; Molfenter, Sonja M; Steele, Catriona M
2008-01-01
Dysphagia, or difficulty swallowing, often occurs secondary to conditions such as stroke, head injury or progressive disease, many of which increase in frequency with advancing age. Sarcopenia, the gradual loss of muscle bulk and strength, can place older individuals at greater risk for dysphagia. Data are reported for three older participants in a pilot trial of a tongue-pressure training therapy. During the experimental therapy protocol, participants performed isometric strength exercises for the tongue as well as tongue pressure accuracy tasks. Biofeedback was provided using the Iowa Oral Performance Instrument (IOPI), an instrument that measures tongue pressure. Treatment outcome measures show increased isometric tongue strength, improved tongue pressure generation accuracy, improved bolus control on videofluoroscopy, and improved functional dietary intake by mouth. These preliminary results indicate that, for these three adults with dysphagia, tongue-pressure training was beneficial for improving both instrumental and functional aspects of swallowing. The experimental treatment protocol holds promise as a rehabilitative tool for various dysphagia populations. PMID:19281066
Atencia, Rebeca; Stöhr, Eric J; Drane, Aimee L; Stembridge, Mike; Howatson, Glyn; Del Rio, Pablo Rodriguez Lopez; Feltrer, Yedra; Tafon, Babila; Redrobe, Sharon; Peck, Bruce; Eng, Jaclyn; Unwin, Steve; Sanchez, Carlos R; Shave, Rob E
2017-09-01
Limited data are available on hemodynamic responses to anesthetic protocols in wild-born chimpanzees (Pan troglodytes). Accordingly, this study characterized the heart rate (HR) and blood pressure responses to four anesthetic protocols in 176 clinically healthy, wild-born chimpanzees undergoing routine health assessments. Animals were anesthetized with medetomidine-ketamine (MK) (n = 101), tiletamine-zolazepam (TZ) (n = 30), tiletamine-zolazepam-medetomidine (TZM) (n = 24), or medetomidine-ketamine (maintained with isoflurane) (MKI) (n = 21). During each procedure, HR, systolic blood pressure (SBP), and diastolic blood pressure (DBP) were regularly recorded. Data were grouped according to anesthetic protocol, and mean HR, SBP, and DBP were calculated. Differences between mean HR, SBP, and DBP for each anesthetic protocol were assessed using the Kruskall-Wallis test and a Dunn multiple comparisons post hoc analysis. To assess the hemodynamic time course response to each anesthetic protocol, group mean data (±95% confidence interval [CI]) were plotted against time postanesthetic induction. Mean HR (beats/min [CI]) was significantly higher in TZ (86 [80-92]) compared to MKI (69 [61-78]) and MK (62 [60-64]) and in TZM (73 [68-78]) compared to MK. The average SBP and DBP values (mm Hg [CI]) were significantly higher in MK (130 [126-134] and 94 [91-97]) compared to TZ (104 [96-112] and 58 [53-93]) and MKI (113 [103-123] and 78 [69-87]) and in TZM (128 [120-135] and 88 [83-93]) compared to TZ. Time course data were markedly different between protocols, with MKI showing the greatest decline over time. Both the anesthetic protocol adopted and the timing of measurement after injection influence hemodynamic recordings in wild-born chimpanzees and need to be considered when monitoring or assessing cardiovascular health.
Schreiner, Markus M; Platzgummer, Hannes; Unterhumer, Sylvia; Weber, Michael; Mistelbauer, Gabriel; Loewe, Christian; Schernthaner, Ruediger E
2017-08-01
To investigate radiation exposure, objective image quality, and the diagnostic accuracy of a BMI-adjusted ultra-low-dose CT angiography (CTA) protocol for the assessment of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the standard of reference. In this prospective, IRB-approved study, 40 PAD patients (30 male, mean age 72 years) underwent CTA on a dual-source CT scanner at 80kV tube voltage. The reference amplitude for tube current modulation was personalized based on the body mass index (BMI) with 120 mAs for [BMI≤25] or 150 mAs for [25
Stagegaard, Julia; Hørlyck, Arne; Hydeskov, Helle B; Bertelsen, Mads F
2017-06-01
Six clinically healthy captive cheetahs ( Acinonyx jubatus ) were anesthetized twice using two different drug combinations to investigate if blood pressure and kidney blood flow are affected by medetomidine dosage. Protocol KM (2.0 mg/kg ketamine and 0.05 mg/kg medetomidine) was compared with protocol KMM (2.0 mg/kg ketamine, 0.02 mg/kg medetomidine, and 0.1 mg/kg midazolam). Heart rate (HR), respiratory rate (RR), body temperature, end-tidal carbon dioxide pressure (ETCO 2 ), and anesthetic depth were monitored every 10 min. Noninvasive mean (MAP), systolic (SAP), and diastolic (DAP) arterial blood pressure were measured, and Duplex Doppler ultrasonography was performed on the kidneys. The mean arterial resistive index (RI) was determined and the pulse pressure index (PPI) was calculated, as indicators for kidney blood flow. There were no significant differences in induction and recovery times. MAP was significantly higher with KM than KMM at 35 min, and in both protocols decreased significantly after atipamezole administration. DAP was significantly higher at 25 and 35 min in animals anesthetized with KM; it also decreased significantly with both protocols after atipamezole administration. The PPI was significantly lower throughout the procedure with KM, and with both protocols increased significantly after atipamezole administration. Both the higher blood pressure and the reduced PPI with KM were likely a direct effect of the higher medetomidine dosage, and these findings indicate that lower medetomidine dosages might reduce hypertension and lead to a better PPI in cheetah immobilization.
Nonpainful wide-area compression inhibits experimental pain.
Honigman, Liat; Bar-Bachar, Ofrit; Yarnitsky, David; Sprecher, Elliot; Granovsky, Yelena
2016-09-01
Compression therapy, a well-recognized treatment for lymphoedema and venous disorders, pressurizes limbs and generates massive non-noxious afferent sensory barrages. The aim of this study was to study whether such afferent activity has an analgesic effect when applied on the lower limbs, hypothesizing that larger compression areas will induce stronger analgesic effects, and whether this effect correlates with conditioned pain modulation (CPM). Thirty young healthy subjects received painful heat and pressure stimuli (47°C for 30 seconds, forearm; 300 kPa for 15 seconds, wrist) before and during 3 compression protocols of either SMALL (up to ankles), MEDIUM (up to knees), or LARGE (up to hips) compression areas. Conditioned pain modulation (heat pain conditioned by noxious cold water) was tested before and after each compression protocol. The LARGE protocol induced more analgesia for heat than the SMALL protocol (P < 0.001). The analgesic effect interacted with gender (P = 0.015). The LARGE protocol was more efficient for females, whereas the MEDIUM protocol was more efficient for males. Pressure pain was reduced by all protocols (P < 0.001) with no differences between protocols and no gender effect. Conditioned pain modulation was more efficient than the compression-induced analgesia. For the LARGE protocol, precompression CPM efficiency positively correlated with compression-induced analgesia. Large body area compression exerts an area-dependent analgesic effect on experimental pain stimuli. The observed correlation with pain inhibition in response to robust non-noxious sensory stimulation may suggest that compression therapy shares similar mechanisms with inhibitory pain modulation assessed through CPM.
Radi, Marjan; Dezfouli, Behnam; Abu Bakar, Kamalrulnizam; Abd Razak, Shukor
2014-01-01
Network connectivity and link quality information are the fundamental requirements of wireless sensor network protocols to perform their desired functionality. Most of the existing discovery protocols have only focused on the neighbor discovery problem, while a few number of them provide an integrated neighbor search and link estimation. As these protocols require a careful parameter adjustment before network deployment, they cannot provide scalable and accurate network initialization in large-scale dense wireless sensor networks with random topology. Furthermore, performance of these protocols has not entirely been evaluated yet. In this paper, we perform a comprehensive simulation study on the efficiency of employing adaptive protocols compared to the existing nonadaptive protocols for initializing sensor networks with random topology. In this regard, we propose adaptive network initialization protocols which integrate the initial neighbor discovery with link quality estimation process to initialize large-scale dense wireless sensor networks without requiring any parameter adjustment before network deployment. To the best of our knowledge, this work is the first attempt to provide a detailed simulation study on the performance of integrated neighbor discovery and link quality estimation protocols for initializing sensor networks. This study can help system designers to determine the most appropriate approach for different applications. PMID:24678277
Control of vertical posture while elevating one foot to avoid a real or virtual obstacle.
Ida, Hirofumi; Mohapatra, Sambit; Aruin, Alexander
2017-06-01
The purpose of this study is to investigate the control of vertical posture during obstacle avoidance in a real versus a virtual reality (VR) environment. Ten healthy participants stood upright and lifted one leg to avoid colliding with a real obstacle sliding on the floor toward a participant and with its virtual image. Virtual obstacles were delivered by a head mounted display (HMD) or a 3D projector. The acceleration of the foot, center of pressure, and electrical activity of the leg and trunk muscles were measured and analyzed during the time intervals typical for early postural adjustments (EPAs), anticipatory postural adjustments (APAs), and compensatory postural adjustments (CPAs). The results showed that the peak acceleration of foot elevation in the HMD condition decreased significantly when compared with that of the real and 3D projector conditions. Reduced activity of the leg and trunk muscles was seen when dealing with virtual obstacles (HMD and 3D projector) as compared with that seen when dealing with real obstacles. These effects were more pronounced during APAs and CPAs. The onsets of muscle activities in the supporting limb were seen during EPAs and APAs. The observed modulation of muscle activity and altered patterns of movement seen while avoiding a virtual obstacle should be considered when designing virtual rehabilitation protocols.
Mammographic compression after breast conserving therapy: Controlling pressure instead of force
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groot, J. E. de, E-mail: jerry.degroot@sigmascreening.com; Branderhorst, W.; Grimbergen, C. A.
Purpose: X-ray mammography is the primary tool for early detection of breast cancer and for follow-up after breast conserving therapy (BCT). BCT-treated breasts are smaller, less elastic, and more sensitive to pain. Instead of the current force-controlled approach of applying the same force to each breast, pressure-controlled protocols aim to improve standardization in terms of physiology by taking breast contact area and inelasticity into account. The purpose of this study is to estimate the potential for pressure protocols to reduce discomfort and pain, particularly the number of severe pain complaints for BCT-treated breasts. Methods: A prospective observational study including 58more » women having one BCT-treated breast and one untreated nonsymptomatic breast, following our hospital's 18 decanewton (daN) compression protocol was performed. Breast thickness, applied force, contact area, mean pressure, breast volume, and inelasticity (mean E-modulus) were statistically compared between the within-women breast pairs, and data were used as predictors for severe pain, i.e., scores 7 and higher on an 11-point Numerical Rating Scale. Curve-fitting models were used to estimate how pressure-controlled protocols affect breast thickness, compression force, and pain experience. Results: BCT-treated breasts had on average 27% smaller contact areas, 30% lower elasticity, and 30% higher pain scores than untreated breasts (allp < 0.001). Contact area was the strongest predictor for severe pain (p < 0.01). Since BCT-treatment is associated with an average 0.36 dm{sup 2} decrease in contact area, as well as increased pain sensitivity, BCT-breasts had on average 5.3 times higher odds for severe pain than untreated breasts. Model estimations for a pressure-controlled protocol with a 10 kPa target pressure, which is below normal arterial pressure, suggest an average 26% (range 10%–36%) reduction in pain score, and an average 77% (range 46%–95%) reduction of the odds for severe pain. The estimated increase in thickness is +6.4% for BCT breasts. Conclusions: After BCT, women have hardly any choice in avoiding an annual follow-up mammogram. Model estimations show that a 10 kPa pressure-controlled protocol has the potential to reduce pain and severe pain particularly for these women. The results highly motivate conducting further research in larger subject groups.« less
Galletti, F; Ferrara, I; Stinga, F; Iacone, R; Noviello, F; Strazzullo, P
1997-04-01
The "gold standard" for the assessment of salt sensitivity of hypertension is the blood pressure response to dietary NaCl restriction; nevertheless, for practical purposes, a more rapid test that would not depend on the patient's compliance to the dietary prescription would be very useful in clinical research and medical practice. The aim of this study was thus to evaluate the effectiveness and reliability of a rapid, easy-to-standardize protocol for the assessment of salt sensitivity against the blood pressure response to dietary salt restriction. A total of 108 hypertensive patients were screened for salt sensitivity by the modified protocol of Grim et al. Thereafter, nine patients identified by the test as salt sensitive and nine identified as salt resistant followed, for two consecutive periods of 1 week, a diet with normal (200 mmol/day) or low (50 mmol/day) NaCl content. Compliance to the diet was checked by repeated 24-h urine collections. The group as a whole experienced a significant fall in blood pressure during the low Na diet (mean pressure = 123 +/- 3 v 118 +/- 3 mm Hg; P < .05). However, whereas patients identified as salt sensitive by the Grim protocol had a marked and significant blood pressure decrease (systolic -12 mm Hg, diastolic -7 mm Hg), no change was observed in those classified as salt resistant (systolic -2 mm Hg, diastolic -2 mm Hg). A significant correlation between changes in urinary Na excretion and changes in blood pressure was found only in salt-sensitive hypertensive patients. In conclusion, the modified Grim protocol tested in this study was able to correctly predict a significant blood pressure response to dietary salt restriction in the majority of cases. A validation of this test in a larger patient population may be advisable.
Colombo, Davide; Cammarota, Gianmaria; Bergamaschi, Valentina; De Lucia, Marta; Corte, Francesco Della; Navalesi, Paolo
2008-11-01
Neurally adjusted ventilatory assist (NAVA) is a new mode wherein the assistance is provided in proportion to diaphragm electrical activity (EAdi). We assessed the physiologic response to varying levels of NAVA and pressure support ventilation (PSV). ICU of a University Hospital. Fourteen intubated and mechanically ventilated patients. DESIGN AND PROTOCOL: Cross-over, prospective, randomized controlled trial. PSV was set to obtain a VT/kg of 6-8 ml/kg with an active inspiration. NAVA was matched with a dedicated software. The assistance was decreased and increased by 50% with both modes. The six assist levels were randomly applied. Arterial blood gases (ABGs), tidal volume (VT/kg), peak EAdi, airway pressure (Paw), neural and flow-based timing. Asynchrony was calculated using the asynchrony index (AI). There was no difference in ABGs regardless of mode and assist level. The differences in breathing pattern, ventilator assistance, and respiratory drive and timing between PSV and NAVA were overall small at the two lower assist levels. At the highest assist level, however, we found greater VT/kg (9.1 +/- 2.2 vs. 7.1 +/- 2 ml/kg, P < 0.001), and lower breathing frequency (12 +/- 6 vs. 18 +/- 8.2, P < 0.001) and peak EAdi (8.6 +/- 10.5 vs. 12.3 +/- 9.0, P < 0.002) in PSV than in NAVA; we found mismatch between neural and flow-based timing in PSV, but not in NAVA. AI exceeded 10% in five (36%) and no (0%) patients with PSV and NAVA, respectively (P < 0.05). Compared to PSV, NAVA averted the risk of over-assistance, avoided patient-ventilator asynchrony, and improved patient-ventilator interaction.
Cho, Min Soo; Jang, Sun-Joo; Lee, Chang Hoon; Park, Chong-Hun
2012-09-01
The relationship between blood pressure (BP) response during exercise and future cardiovascular events remains unclear. We assessed the association between an increase in early systolic BP (SBP) during exercise tests and future cardiovascular events in patients with sustained hypertension (sHT). Between 2002 and 2005, we enrolled 300 patients newly diagnosed with mild-to-moderate sHT without complications from the Asan Ambulatory Blood Pressure Monitoring registry. All the patients successfully performed treadmill tests, achieving target heart rate according to the Naughton/Balke protocol. The patients were divided into quartiles according to their SBP at 8 min (7.4 metabolic equivalent tasks). The primary outcome was the composite of all-cause death, new-onset ischemic heart disease and stroke. The 5-year survival rates did not differ significantly among quartiles 1-4 (100% vs. 96.6% vs. 94.4% vs. 98.3%, P=0.211). Relative to quartile 1, the 5-year event-free survival rates were significantly lower in patients in quartiles 3 (86.9% vs. 98.3%, P=0.023) and 4 (88.2% vs. 98.3%, P=0.023). After multivariable adjustment for covariates, the risk for the composite end point was higher for patients in quartiles 3 (Hazard ratio (HR) 4.69, 95% confidence interval (CI) 1.28-17.13, P=0.020) and 4 (HR 3.65, 95% CI 0.92-14.50, P=0.065) than in quartiles 1 and 2. Cardiovascular risk was significantly higher in patients with stage 4 SBP (>180 mm Hg) even after adjustment (HR 4.00, 95% CI 1.19-13.44, P=0.025). Increased submaximal SBP response to exercise may be a predictor of future cardiovascular events in patients with mild-to-moderate sHT.
Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection.
Pravadali-Cekic, Sercan; Kocic, Danijela; Hua, Stanley; Jones, Andrew; Dennis, Gary R; Shalliker, R Andrew
2015-12-15
Active flow technology (AFT) is new form of column technology that was designed to overcome flow heterogeneity to increase separation performance in terms of efficiency and sensitivity and to enable multiplexed detection. This form of AFT uses a parallel segmented flow (PSF) column. A PSF column outlet end-fitting consists of 2 or 4 ports, which can be multiplexed to connect up to 4 detectors. The PSF column not only allows a platform for multiplexed detection but also the combination of both destructive and non-destructive detectors, without additional dead volume tubing, simultaneously. The amount of flow through each port can also be adjusted through pressure management to suit the requirements of a specific detector(s). To achieve multiplexed detection using a PSF column there are a number of parameters which can be controlled to ensure optimal separation performance and quality of results; that is tube dimensions for each port, choice of port for each type of detector and flow adjustment. This protocol is intended to show how to use and tune a PSF column functioning in a multiplexed mode of detection.
Steele, Catriona M; Bayley, Mark T; Peladeau-Pigeon, Melanie; Nagy, Ahmed; Namasivayam, Ashwini M; Stokely, Shauna L; Wolkin, Talia
2016-06-01
The objective of this study was to compare the outcomes of two tongue resistance training protocols. One protocol ("tongue-pressure profile training") emphasized the pressure-timing patterns that are typically seen in healthy swallows by focusing on gradual pressure release and saliva swallowing tasks. The second protocol ("tongue-pressure strength and accuracy training") emphasized strength and accuracy in tongue-palate pressure generation and did not include swallowing tasks. A prospective, randomized, parallel allocation trial was conducted. Of 26 participants who were screened for eligibility, 14 received up to 24 sessions of treatment. Outcome measures of posterior tongue strength, oral bolus control, penetration-aspiration and vallecular residue were made based on videofluoroscopy analysis by blinded raters. Complete data were available for 11 participants. Significant improvements were seen in tongue strength and post-swallow vallecular residue with thin liquids, regardless of treatment condition. Stage transition duration (a measure of the duration of the bolus presence in the pharynx prior to swallow initiation, which had been chosen to capture impairments in oral bolus control) showed no significant differences. Similarly, significant improvements were not seen in median scores on the penetration-aspiration scale. This trial suggests that tongue strength can be improved with resistance training for individuals with tongue weakness following stroke. We conclude that improved penetration-aspiration does not necessarily accompany improvements in tongue strength; however, tongue-pressure resistance training does appear to be effective for reducing thin liquid vallecular residue.
Randall, Edin T; Bohnert, Amy M; Travers, Lea V
2015-06-01
This cross-sectional study examined relations between affluent adolescent adjustment and culturally salient factors within parent-child relationship and extracurricular domain. Bootstrapping techniques evaluated mediated effects among parental perfectionism, perceived parental pressure, intensity of organized activity (OA) involvement, and adolescent adjustment (i.e., depressive and anxiety symptoms, life satisfaction) within a sample of 10th graders and their parents (n = 88 parent-child pairs) from four high schools in affluent communities. Findings indicated that adolescents with more perfectionistic parents perceived more parental pressure and experienced poorer adjustment. Results also demonstrated that affluent adolescents who perceived more parental pressure were more intensely involved in OAs, but that higher OA intensity was linked to better adjustment. Findings highlight the importance of considering parental perfectionism when understanding adolescent behaviors and psychological outcomes, confirm the negative direct effects of parental pressure on adjustment, and corroborate prior research dispelling that highly intense OA involvement is linked to adolescent maladjustment. Copyright © 2015 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.
Pini, Claudio; Pastori, Marco; Baccheschi, Jordan; Omboni, Stefano; Parati, Gianfranco
2007-06-01
There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). The Artsana CSI 610 device successfully passed phase 1 of study validation with the number of absolute differences between test and reference device never <35 within 5 mmHg and never <40 within 10 and 15 mmHg. The test device also passed phase 2 of the validation study with a mean (+/-SD) device-observer difference of -1.4+/-4.8 mmHg for systolic and -0.9+/-3.5 mmHg for diastolic blood pressure. According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.
Tian, Huiyong; Zeng, Sijian; Zhong, Xiaoyan; Gong, Wei; Liu, Wenjun
2015-10-01
Transtek blood pressure monitor TMB-1491 is an automatic upper arm device designed for self/home measurement in adult populations. This study aimed to evaluate its accuracy according to the European Society of Hypertension International Protocol revision 2010. The protocol requirements were followed precisely with the recruitment of 33 adult individuals on whom same-left-arm sequential systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements were obtained in this study (three pairs for each of the 33 participants). The device produced 74, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 85, 97, and 99 for DBP, respectively. The mean±SD device-observer difference was -0.6±4.4 mmHg for SBP and -0.6±3.4 mmHg for DBP. The number of participants with two or three device-observer difference within 5 mmHg was 24 for SBP and 29 for DBP. In addition, none of the participants had a device-observer difference within 5 mmHg for SBP, and three of the participants had the same for DBP. Transtek TMB-1491 has passed all phases of European Society of Hypertension International Protocol revision 2010 and can be recommended for self/home measurement in adult populations.
Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng
2014-08-01
To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.
Fuller, Brian M; Ferguson, Ian T; Mohr, Nicholas M; Drewry, Anne M; Palmer, Christopher; Wessman, Brian T; Ablordeppey, Enyo; Keeperman, Jacob; Stephens, Robert J; Briscoe, Cristopher C; Kolomiets, Angelina A; Hotchkiss, Richard S; Kollef, Marin H
2017-09-01
We evaluated the efficacy of an emergency department (ED)-based lung-protective mechanical ventilation protocol for the prevention of pulmonary complications. This was a quasi-experimental, before-after study that consisted of a preintervention period, a run-in period of approximately 6 months, and a prospective intervention period. The intervention was a multifaceted ED-based mechanical ventilator protocol targeting lung-protective tidal volume, appropriate setting of positive end-expiratory pressure, rapid oxygen weaning, and head-of-bed elevation. A propensity score-matched analysis was used to evaluate the primary outcome, which was the composite incidence of acute respiratory distress syndrome and ventilator-associated conditions. A total of 1,192 patients in the preintervention group and 513 patients in the intervention group were included. Lung-protective ventilation increased by 48.4% in the intervention group. In the propensity score-matched analysis (n=490 in each group), the primary outcome occurred in 71 patients (14.5%) in the preintervention group compared with 36 patients (7.4%) in the intervention group (adjusted odds ratio 0.47; 95% confidence interval [CI] 0.31 to 0.71). There was an increase in ventilator-free days (mean difference 3.7; 95% CI 2.3 to 5.1), ICU-free days (mean difference 2.4; 95% CI 1.0 to 3.7), and hospital-free days (mean difference 2.4; 95% CI 1.2 to 3.6) associated with the intervention. The mortality rate was 34.1% in the preintervention group and 19.6% in the intervention group (adjusted odds ratio 0.47; 95% CI 0.35 to 0.63). Implementing a mechanical ventilator protocol in the ED is feasible and is associated with significant improvements in the delivery of safe mechanical ventilation and clinical outcome. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Reid, Christopher M; Ryan, Philip; Miles, Helen; Willson, Kristyn; Beilin, Laurence J; Brown, Mark A; Jennings, Garry L; Johnston, Colin I; Macdonald, Graham J; Marley, John E; McNeil, John J; Morgan, Trefor O; West, Malcolm J; Wing, Lindon M H
2005-01-01
The characterization of blood pressure in treatment trials assessing the benefits of blood pressure lowering regimens is a critical factor for the appropriate interpretation of study results. With numerous operators involved in the measurement of blood pressure in many thousands of patients being screened for entry into clinical trials, it is essential that operators follow pre-defined measurement protocols involving multiple measurements and standardized techniques. Blood pressure measurement protocols have been developed by international societies and emphasize the importance of appropriate choice of cuff size, identification of Korotkoff sounds, and digit preference. Training of operators and auditing of blood pressure measurement may assist in reducing the operator-related errors in measurement. This paper describes the quality control activities adopted for the screening stage of the 2nd Australian National Blood Pressure Study (ANBP2). ANBP2 is cardiovascular outcome trial of the treatment of hypertension in the elderly that was conducted entirely in general practices in Australia. A total of 54 288 subjects were screened; 3688 previously untreated subjects were identified as having blood pressure >140/90 mmHg at the initial screening visit, 898 (24%) were not eligible for study entry after two further visits due to the elevated reading not being sustained. For both systolic and diastolic blood pressure recording, observed digit preference fell within 7 percentage points of the expected frequency. Protocol adherence, in terms of the required minimum blood pressure difference between the last two successive recordings, was 99.8%. These data suggest that adherence to blood pressure recording protocols and elimination of digit preferences can be achieved through appropriate training programs and quality control activities in large multi-centre community-based trials in general practice. Repeated blood pressure measurement prior to initial diagnosis and study entry is essential to appropriately characterize hypertension in these elderly patients.
Abrahams, Alferso C; Rüger, Wim; Ter Wee, Pieter M; van Ittersum, Frans J; Boer, Walther H
2017-01-01
♦ BACKGROUND: Peritonitis is a major cause of morbidity, mortality, and technique failure in peritoneal dialysis (PD) patients, especially when caused by enteric microorganisms (EM). We have implemented a treatment protocol specifically aimed at improving the outcome in EM peritonitis. The adapted protocol was applied in all PD patients 50 years and older presenting with peritonitis who were considered to be at risk of EM peritonitis and involves 3 interventions: 1) temporary discontinuation of PD without removing the catheter (peritoneal rest), 2) intravenous meropenem, and 3) meropenem intracatheter as lock (Mero-PerRest protocol). ♦ METHODS: In this observational study, we compared the outcome of 203 peritonitis episodes in 71 patients treated with the Mero-PerRest protocol, with 217 episodes in 104 patients treated with a more traditional intraperitoneal gentamicin-rifampicin-based regimen. ♦ RESULTS: In EM peritonitis episodes, the Mero-PerRest protocol resulted in a higher primary cure rate (90.0% vs 65.3%, adjusted odds ratio [OR] 4.54 [95% confidence interval (CI) 1.46 - 14.15]) and better technique survival (90.0% vs 69.4%, adjusted OR 3.41 [95% CI 1.07 - 10.87]). This effect was most distinct in patients with polymicrobial EM peritonitis (cure rate 87.5% vs 34.8%, p = 0.0003). Interestingly, primary cure rate (95.6% vs 84.7%, adjusted OR 3.92 [95% CI 1.37 - 11.19]) and technique survival (95.6% vs 85.6%, adjusted OR 3.60 [95% CI 1.25 - 10.32]) were also excellent in non-EM peritonitis episodes. Patient survival did not differ significantly. ♦ CONCLUSION: The poor outcome of peritonitis caused by EM in PD patients aged 50 years and older could be improved by applying a treatment protocol involving temporary discontinuation of PD without catheter removal and intravenous and intracatheter meropenem. Copyright © 2017 International Society for Peritoneal Dialysis.
Sun, Z; Al Ghamdi, KS; Baroum, IH
2012-01-01
Purpose: To investigate whether the multislice CT scanning protocols of head, chest and abdomen are adjusted according to patient’s age in paediatric patients. Materials and Methods: Multislice CT examination records of paediatric patients undergoing head, chest and abdomen scans from three public hospitals during a one-year period were retrospectively reviewed. Patients were categorised into the following age groups: under 4 years, 5–8 years, 9–12 years and 13–16 years, while the tube current was classified into the following ranges: < 49 mA, 50–99 mA, 100–149 mA, 150–199 mA, > 200 mA and unknown. Results: A total of 4998 patient records, comprising a combination of head, chest and abdomen CT scans, were assessed, with head CT scans representing nearly half of the total scans. Age-based adjusted CT protocols were observed in most of the scans with higher tube current setting being used with increasing age. However, a high tube current (150–199 mA) was still used in younger patients (0–8 years) undergoing head CT scans. In one hospital, CT protocols remained constant across all age groups, indicating potential overexposure to the patients. Conclusion: This analysis shows that paediatric CT scans are adjusted according to the patient’s age in most of the routine CT examinations. This indicates increased awareness regarding radiation risks associated with CT. However, high tube current settings are still used in younger patient groups, thus, optimisation of paediatric CT protocols and implementation of current guidelines, such as age-and weight-based scanning, should be recommended in daily practice. PMID:22970059
Steptoe, A; Cropley, M; Griffith, J; Joekes, K
1999-11-01
To assess the influence of abdominal obesity and work stress (operationalised as low control over work) on ambulatory blood pressure on a working day and evening. 156 school teachers (58 men and 98 women) carried out ambulatory blood pressure and heart rate monitoring on a work day and evening. Cardiovascular activity was also measured under baseline conditions on another occasion, when body weight, height, waist and hip circumference were assessed. Perceived control over work was assessed by questionnaire, along with mental health, anger expression and social support. 126 participants repeated the protocol after 12 months. Waist/hip ratio was used as the index of abdominal obesity. Baseline blood pressure was positively associated with waist/hip ratio in men, but ambulatory blood pressure and heart rate were not independently related to waist/hip ratio or job control. However, blood pressure and heart rate recorded during the working day and evening were elevated in men with high waist/hip ratio who experienced low job control, independently of age and body weight. Effects for diastolic blood pressure and heart rate were replicated after 12 months. Body mass index was not related to blood pressure or heart rate during the day or evening after adjustment for age and waist circumference. Low job control was associated with poor psychological well-being, negative mood and lack of social support. The results are consistent with the hypothesis that abdominal obesity in men is characterised by a tendency towards heightened stress-induced physiological activation, but that this tendency will only be manifest in the presence of appropriate environmental challenges such as chronic work stress.
Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang
2017-12-01
The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.
Pulse pressure variation-guided fluid therapy after cardiac surgery: a pilot before-and-after trial.
Suzuki, Satoshi; Woinarski, Nicholas C Z; Lipcsey, Miklos; Candal, Cristina Lluch; Schneider, Antoine G; Glassford, Neil J; Eastwood, Glenn M; Bellomo, Rinaldo
2014-12-01
The aim of this study is to study the feasibility, safety, and physiological effects of pulse pressure variation (PPV)-guided fluid therapy in patients after cardiac surgery. We conducted a pilot prospective before-and-after study during mandatory ventilation after cardiac surgery in a tertiary intensive care unit. We introduced a protocol to deliver a fluid bolus for a PPV≥13% for at least >10 minutes during the intervention period. We studied 45 control patients and 53 intervention patients. During the intervention period, clinicians administered a fluid bolus on 79% of the defined PPV trigger episodes. Median total fluid intake was similar between 2 groups during mandatory ventilation (1297 mL [interquartile range 549-1968] vs 1481 mL [807-2563]; P=.17) and the first 24 hours (3046 mL [interquartile range 2317-3982] vs 3017 mL [2192-4028]; P=.73). After adjusting for several baseline factors, PPV-guided fluid management significantly increased fluid intake during mandatory ventilation (P=.004) but not during the first 24 hours (P=.47). Pulse pressure variation-guided fluid therapy, however, did not significantly affect hemodynamic, renal, and metabolic variables. No serious adverse events were noted. Pulse pressure variation-guided fluid management was feasible and safe during mandatory ventilation after cardiac surgery. However, its advantages may be clinically small. Copyright © 2014 Elsevier Inc. All rights reserved.
Success and duration of dynamic bracing for pectus carinatum: A four-year prospective study.
Emil, Sherif; Sévigny, Marika; Montpetit, Kathleen; Baird, Robert; Laberge, Jean-Martin; Goyette, Jade; Finlay, Ian; Courchesne, Guylaine
2017-01-01
This study sought to establish factors that can prognosticate outcomes of bracing for pectus carinatum (PC). Prospective data were collected on all patients enrolled in a dynamic bracing protocol from July 2011 to July 2015. Pressure of correction (POC) was measured at initiation of treatment, and pressure of treatment (POT) was measured pre- and post-adjustment at every follow-up visit. Univariate and Cox regression analysis tested the following possible determinants of success and bracing duration: age, sex, symmetry, POC, and POT drop during the first two follow-up visits. Of 114 patients, 64 (56%) succeeded, 33 (29%) were still in active bracing, and 17 (15%) failed or were lost to follow-up. In successful patients, active and maintenance bracing was 5.66±3.81 and 8.80±3.94months, respectively. Asymmetry and older age were significantly associated with failure. Multivariable Cox proportional hazard analysis of time-to-maintenance showed that asymmetry (p=0.01) and smaller first drop in POT (p=0.02) were associated with longer time to reach maintenance. Pressure of correction does not predict failure of bracing, but older age, asymmetry, and smaller first drop in pressure of treatment are associated with failure and longer bracing duration. Prospective Study/Level of Evidence IV. Copyright © 2017 Elsevier Inc. All rights reserved.
Nonpainful wide-area compression inhibits experimental pain
Honigman, Liat; Bar-Bachar, Ofrit; Yarnitsky, David; Sprecher, Elliot; Granovsky, Yelena
2016-01-01
Abstract Compression therapy, a well-recognized treatment for lymphoedema and venous disorders, pressurizes limbs and generates massive non-noxious afferent sensory barrages. The aim of this study was to study whether such afferent activity has an analgesic effect when applied on the lower limbs, hypothesizing that larger compression areas will induce stronger analgesic effects, and whether this effect correlates with conditioned pain modulation (CPM). Thirty young healthy subjects received painful heat and pressure stimuli (47°C for 30 seconds, forearm; 300 kPa for 15 seconds, wrist) before and during 3 compression protocols of either SMALL (up to ankles), MEDIUM (up to knees), or LARGE (up to hips) compression areas. Conditioned pain modulation (heat pain conditioned by noxious cold water) was tested before and after each compression protocol. The LARGE protocol induced more analgesia for heat than the SMALL protocol (P < 0.001). The analgesic effect interacted with gender (P = 0.015). The LARGE protocol was more efficient for females, whereas the MEDIUM protocol was more efficient for males. Pressure pain was reduced by all protocols (P < 0.001) with no differences between protocols and no gender effect. Conditioned pain modulation was more efficient than the compression-induced analgesia. For the LARGE protocol, precompression CPM efficiency positively correlated with compression-induced analgesia. Large body area compression exerts an area-dependent analgesic effect on experimental pain stimuli. The observed correlation with pain inhibition in response to robust non-noxious sensory stimulation may suggest that compression therapy shares similar mechanisms with inhibitory pain modulation assessed through CPM. PMID:27152691
Solinsky, Ryan; Svircev, Jelena N; James, Jennifer J; Burns, Stephen P; Bunnell, Aaron E
2016-11-01
Autonomic dysreflexia is a potentially life-threatening condition which afflicts a significant proportion of individuals with spinal cord injuries (SCI). To date, the safety and efficacy of several commonly used interventions for this condition have not been studied. A retrospective chart review of the safety of a previously implemented nursing driven inpatient autonomic dysreflexia protocol. Seventy-eight male patients with SCI who experienced autonomic dysreflexia while inpatient at our Veterans Affairs SCI unit over a 3-1/2-year period were included. The safety of a nursing driven protocol utilizing conservative measures, nitroglycerin paste, and oral hydralazine was evaluated. Occurrence of adverse events and relative hypotensive events during all episodes treated with the protocol, and efficacy of attaining target blood pressure for all episodes with protocol adherence and for initial episode experienced by each patient. Four hundred forty-five episodes of autonomic dysreflexia were recorded in the study period, with 92% adherence to the protocol. When the protocol was followed, target blood pressure was achieved for 97.6% of all episodes. Twenty-three total adverse events occurred (5.2% of all episodes). All adverse events were due to hypotension and only 0.9% required interventions beyond clinical monitoring. Of each patient's initial autonomic dysreflexia episode, 97.3% resolved using the protocol without need for further escalation of care. This inpatient nursing driven-protocol for treating autonomic dysreflexia utilizing conservative measures, nitroglycerin paste and oral hydralazine achieved target blood pressure with a high success rate and a low incidence of adverse events.
Liu, Bian; Lau, Kui Kai; Li, Linxin; Lovelock, Caroline; Liu, Ming; Kuker, Wilhelm
2018-01-01
Background and Purpose— It has been hypothesized that cerebral small vessel disease (SVD) and chronic renal impairment may be part of a multisystem small-vessel disorder, but their association may simply be as a result of shared risk factors (eg, hypertension) rather than to a systemic susceptibility to premature SVD. However, most previous studies were hospital based, most had inadequate adjustment for hypertension, many were confined to patients with lacunar stroke, and none stratified by age. Methods— In a population-based study of transient ischemic attack and ischemic stroke (OXVASC [Oxford Vascular Study]), we evaluated the magnetic resonance imaging markers of cerebral SVD, including lacunes, white matter hyperintensities, cerebral microbleeds, and enlarged perivascular space. We studied the age-specific associations of renal impairment (estimated glomerular filtration rate <60 mL/min per 1.73 m2) and total SVD burden (total SVD score) adjusting for age, sex, vascular risk factors, and premorbid blood pressure (mean blood pressure during 15 years preevent). Results— Of 1080 consecutive patients, 1028 (95.2%) had complete magnetic resonance imaging protocol and creatinine measured at baseline. Renal impairment was associated with total SVD score (odds ratio [OR], 2.16; 95% confidence interval [CI], 1.69–2.75; P<0.001), but only at age <60 years (<60 years: OR, 3.97; 95% CI, 1.69–9.32; P=0.002; 60–79 years: OR, 1.01; 95% CI, 0.72–1.41; P=0.963; ≥80 years: OR, 0.95; 95% CI, 0.59–1.54; P=0.832). The overall association of renal impairment and total SVD score was also attenuated after adjustment for age, sex, history of hypertension, diabetes mellitus, and premorbid average systolic blood pressure (adjusted OR, 0.76; 95% CI, 0.56–1.02; P=0.067), but the independent association of renal impairment and total SVD score at age <60 years was maintained (adjusted OR, 3.11; 95% CI, 1.21–7.98; P=0.018). Associations of renal impairment and SVD were consistent for each SVD marker at age <60 years but were strongest for cerebral microbleeds (OR, 5.84; 95% CI, 1.45–23.53; P=0.013) and moderate–severe periventricular white matter hyperintensities (OR, 6.28; 95% CI, 1.54–25.63; P=0.010). Conclusions— The association of renal impairment and cerebral SVD was attenuated with adjustment for shared risk factors at older ages, but remained at younger ages, consistent with a shared susceptibility to premature disease. PMID:29523652
Steele, Catriona M; Bayley, Mark A; Péladeau-Pigeon, Melanie; Stokely, Shauna L
2013-05-07
It is estimated that approximately 50% of stroke survivors will experience swallowing difficulty, or dysphagia. The associated sequelae of dysphagia include dehydration, malnutrition, and aspiration pneumonia, all of which have can have serious medical consequences. To improve swallowing safety and efficiency, alternative nutritional intake methods (for example, a feeding tube) or a modified diet texture (such as pureed foods or thickened liquids) may be recommended but these modifications may negatively affect quality of life. An alternative approach to treating dysphagia has emerged over the past few years, targeting stronger lingual muscles through maximal isometric pressure tasks. Although these studies have shown promising results, thin-liquid bolus control continues to be challenging for patients with dysphagia. Previous work investigating lingual pressures when healthy participants swallow has suggested that greater task specificity in lingual exercises may yield improved results with thin liquids. This is a small, exploratory randomized clinical trial being conducted with post-stroke patients 4 to 20 weeks after onset of dysphagia secondary to impaired lingual control. At enrollment, participants are randomly assigned to one of two treatment protocols, either tongue pressure profile training (TPPT) or the control treatment, tongue pressure strength-and-accuracy training (TPSAT). Each treatment protocol consists of 24 sessions of treatment over 8 to 12 weeks with monitoring of tongue pressure as well as a baseline and outcome videofluoroscopic swallowing study. Tongue pressure measures, videofluoroscopic measures, and functional outcome measures will be obtained following training of 60 participants (30 in each condition), to determine whether TPPT yields better outcomes. This study will continue to explore options beyond tube feeding and modified diets for people with neurogenic dysphagia following stroke. Should the novel protocol, TPPT, prove to be more effective than the TPSAT protocol, this may influence standards of care and best practices for patients with dysphagia involving impaired thin-liquid control as a result of stroke. Clinicaltrials.gov http://NCT01370083.
Lucas, Rebekah A. I.; Pearson, James; Schlader, Zachary J.; Crandall, Craig G.
2016-01-01
This study tested the hypothesis that baroreceptor unloading during passive hyperthermia contributes to increases in ventilation and decreases in end-tidal partial pressure of carbon dioxide (PET,CO2) during that exposure. Two protocols were performed, in which healthy subjects underwent passive hyperthermia (increasing intestinal temperature by ~1.8°C) to cause a sustained increase in ventilation and reduction in PET,CO2. Upon attaining hyperthermic hyperventilation, in protocol 1 (n = 10; three females) a bolus (19 ± 2 ml kg−1) of warm (~38°C) isotonic saline was rapidly (5–10 min) infused intravenously to restore reductions in central venous pressure, whereas in protocol 2 (n = 11; five females) phenylephrine was infused intravenously (60–120 μg min−1) to return mean arterial pressure to normothermic levels. In protocol 1, hyperthermia increased ventilation (by 2.2 ± 1.7 l min−1, P < 0.01), while reducing PET,CO2 (by 4 ± 3 mmHg, P = 0.04) and central venous pressure (by 5 ± 1 mmHg, P <0.01). Saline infusion increased central venous pressure by 5 ± 1 mmHg (P < 0.01), restoring it to normothermic values, but did not change ventilation or PET,CO2 (P > 0.05). In protocol 2, hyperthermia increased ventilation (by 5.0 ± 2.7l min−1, P <0.01) and reduced PET ,CO2 (by 5 ± 2 mmHg, P < 0.01) and mean arterial pressure (by 9 ± 7 mmHg, P <0.01). Phenylephrine infusion increased mean arterial pressure by 12 ± 3 mmHg (P < 0.01), restoring it to normothermic values, but did not change ventilation or PET,CO2 (P > 0.05). The absence of a reduction in ventilation upon reloading the cardiopulmonary and arterial baroreceptors to pre-hyperthermic levels indicates that baroreceptor unloading with hyperthermia is unlikely to contribute to hyperthermic hyperventilation in humans. PMID:26299270
Rating long-term care facilities on pressure ulcer development: importance of case-mix adjustment.
Berlowitz, D R; Ash, A S; Brandeis, G H; Brand, H K; Halpern, J L; Moskowitz, M A
1996-03-15
To determine the importance of case-mix adjustment in interpreting differences in rates of pressure ulcer development in Department of Veterans Affairs long- term care facilities. A sample assembled from the Patient Assessment File, a Veterans Affairs administrative database, was used to derive predictors of pressure ulcer development; the resulting model was validated in a separate sample. Facility-level rates of pressure ulcer development, both unadjusted and adjusted for case mix using the predictive model, were compared. Department of Veterans Affairs long-term care facilities. The derivation sample consisted of 31 150 intermediate medicine and nursing home residents who were initially free of pressure ulcers and were institutionalized between October 1991 and April 1993. The validation sample consisted of 17 946 residents institutionalized from April 1993 to October 1993. Development of a stage 2 or greater pressure ulcer. 11 factors predicted pressure ulcer development. Validated performance properties of the resulting model were good. Model-predicted rates of pressure ulcer development at individual long-term care facilities varied from 1.9% to 6.3%, and observed rates ranged from 0% to 10.9%. Case-mix-adjusted rates and ranks of facilities differed considerably from unadjusted ratings. For example, among five facilities that were identified as high outliers on the basis of unadjusted rates, two remained as outliers after adjustment for case mix. Long-term care facilities differ in case mix. Adjustments for case mix result in different judgments about facility performance and should be used when facility incidence rates are compared.
Grace Kho, Woei Feng; Cheah, Whye Lian; Hazmi, Helmy
2018-03-01
Hypertension is a health issue affecting adolescents. Accumulating evidence affirms that elevated blood pressure begins in childhood and tracks into adulthood. This cross-sectional study was conducted to determine the prevalence of elevated blood pressure and its predictors among secondary school students in Sarawak, Malaysia. A total of 2,461 secondary school students aged 12-17 years from 19 schools in Sarawak participated in the study. Questionnaire was used to obtain socio-demographic data, parental history of hypertension, and self-reported physical activity. Anthropometric and blood pressure measurements were taken. Data was entered and analysed using SPSS version 23.0. The prevalence of adolescents with elevated blood pressure, overweight, central obesity, and overfat were 30.1%, 24.3%, 13.5%, and 6.7%, respectively. Multivariate logistic regression demonstrated the predictors significantly associated with elevated blood pressure among respondents: overweight (adjusted odds ratio=3.144), being male (adjusted odds ratio=3.073), being Chinese (adjusted odds ratio=2.321) or Iban (adjusted odds ratio=1.578), central obesity (adjusted odds ratio=2.145), being overfat (adjusted odds ratio=1.885), and being an older adolescent (adjusted odds ratio=1.109). Parental history of hypertension, locality, and physical activity showed no significant associations. The obesity epidemic must be tackled at community and school levels by health education and regulation of school canteen foods. Copyright© by the National Institute of Public Health, Prague 2018.
Kwong, Enid Wai-yung; Lee, Paul Hong; Yeung, Kwan-mo
2016-01-18
Because the demand for government-subsidized nursing homes in Hong Kong outstrips the supply, the number of for-profit private nursing homes has been increasing rapidly. However, the standard of care in such homes is always criticized. Pressure ulcers are a major long-term care issue that is closely associated with the quality of care delivered in nursing home settings. The aim of this study is to evaluate the effectiveness of a pressure ulcer prevention programme for residents in private for-profit nursing homes. This is a two-arm cluster randomized controlled trial with an estimated sample size of 1088 residents and 74 care staff from eight for-profit private nursing homes. Eligible nursing homes will be those classified as category A2 homes in the Enhanced Bought Place Scheme (EBPS), having a capacity of around 130-150 beds, and no structured PU prevention protocol and/or programmes in place. Care staff will be health workers, personal care workers, and nurses who are front-line staff providing direct care to residents. Eight nursing homes will be randomly assigned to either an experimental or control group. The experimental group will be provided with an intensive training programme and will be involved in the implementation of a 16-week pressure ulcer prevention protocol, while the control group will deliver the usual pressure ulcer prevention care. The study outcomes are the pressure ulcer prevention knowledge and skills of the care staff and the prevalence and incidence of pressure ulcers. Data on the knowledge and skills of care staff, and prevalence of pressure ulcer will be collected at the base line, and then at the 8(th) week and at completion of the implementation of the protocol. The assessment of the incidence of pressures will start from before the commencement of the intensive training course to the end of the implementation of the protocol. In view of the negative impact of pressure ulcers, it is important to have an effective and evidence-based pressure ulcer prevention programme to improve preventive care in private for-profit nursing homes. The programme will potentially improve the knowledge and skills of care staff on the prevention of pressure ulcers and also lead to a reduction in the development of pressure ulcers in nursing homes. The Current Controlled Trial is NCT02270385, 18 October 2014.
Sheleg, Sergey; Hixon, Hugh; Cohen, Bruce; Lowry, David; Nedzved, Mikhail
2008-01-01
We investigated a new cryopreservation method using xenon, a clathrate-forming gas, under medium pressure (100psi). The objective of the study was to determine whether this cryostasis protocol could protect cardiac mitochondria at cryogenic temperatures (below 100 degrees Celsius).We analyzed transmission electron microscopy images to obtain information about changes in mitochondrial morphology induced by cryopreservation of the hearts. Our data showed absence of mitochondrial swelling, rupture of inner and outer membranes, and leakage of mitochondrial matrix into the cytoplasm after applying this cryostasis protocol. The electron microscopy results provided the first evidence that a cryostasis protocol using xenon as a clathrate-forming gas under pressure may have protective effects on intracellular membranes. This cryostasis technology may find applications in developing new approaches for long-term cryopreservation protocols. PMID:18787624
Fernando, Malindu E.; Crowther, Robert G.; Lazzarini, Peter A.; Yogakanthi, Saiumaeswar; Sangla, Kunwarjit S.; Buttner, Petra; Jones, Rhondda; Golledge, Jonathan
2017-01-01
Objective High plantar pressures are implicated in the development of diabetes-related foot ulcers. Whether plantar pressures remain high in patients with chronic diabetes-related foot ulcers over time is uncertain. The primary aim of this study was to compare plantar pressures at baseline and three and six months later in participants with chronic diabetes-related foot ulcers (cases) to participants without foot ulcers (controls). Methods Standardised protocols were used to measure mean peak plantar pressure and pressure-time integral at 10 plantar foot sites (the hallux, toes, metatarsals 1 to 5, mid-foot, medial heel and lateral heel) during barefoot walking. Measurements were performed at three study visits: baseline, three and six months. Linear mixed effects random-intercept models were utilised to assess whether plantar pressures differed between cases and controls after adjusting for age, sex, body mass index, neuropathy status and follow-up time. Standardised mean differences (Cohen’s d) were used to measure effect size. Results Twenty-one cases and 69 controls started the study and 16 cases and 63 controls completed the study. Cases had a higher mean peak plantar pressure at several foot sites including the toes (p = 0.005, Cohen’s d = 0.36) and mid-foot (p = 0.01, d = 0.36) and a higher pressure-time integral at the hallux (p<0.001, d = 0.42), metatarsal 1 (p = 0.02, d = 0.33) and mid-foot (p = 0.04, d = 0.64) compared to controls throughout follow-up. A reduction in pressure-time integral at multiple plantar sites over time was detected in all participants (p<0.05, respectively). Conclusions Plantar pressures assessed during gait are higher in diabetes patients with chronic foot ulcers than controls at several plantar sites throughout prolonged follow-up. Long term offloading is needed in diabetes patients with diabetes-related foot ulcers to facilitate ulcer healing. PMID:28859075
The association of estimated salt intake with blood pressure in a Viet Nam national survey.
Jensen, Paul N; Bao, Tran Quoc; Huong, Tran Thi Thanh; Heckbert, Susan R; Fitzpatrick, Annette L; LoGerfo, James P; Ngoc, Truong Le Van; Mokdad, Ali H
2018-01-01
To evaluate the association of salt consumption with blood pressure in Viet Nam, a developing country with a high level of salt consumption. Analysis of a nationally representative sample of Vietnamese adults 25-65 years of age who were surveyed using the World Health Organization STEPwise approach to Surveillance protocol. Participants who reported acute illness, pregnancy, or current use of antihypertensive medications were excluded. Daily salt consumption was estimated from fasting mid-morning spot urine samples. Associations of salt consumption with systolic blood pressure and prevalent hypertension were assessed using adjusted linear and generalized linear models. Interaction terms were tested to assess differences by age, smoking, alcohol consumption, and rural/urban status. The analysis included 2,333 participants (mean age: 37 years, 46% male, 33% urban). The average estimated salt consumption was 10g/day. No associations of salt consumption with blood pressure or prevalent hypertension were observed at a national scale in men or women. The associations did not differ in subgroups defined by age, smoking, or alcohol consumption; however, associations differed between urban and rural participants (p-value for interaction of urban/rural status with salt consumption, p = 0.02), suggesting that higher salt consumption may be associated with higher systolic blood pressure in urban residents but lower systolic blood pressure in rural residents. Although there was no evidence of an association at a national level, associations of salt consumption with blood pressure differed between urban and rural residents in Viet Nam. The reasons for this differential association are not clear, and given the large rate of rural to urban migration experienced in Viet Nam, this topic warrants further investigation.
The association of estimated salt intake with blood pressure in a Viet Nam national survey
Bao, Tran Quoc; Huong, Tran Thi Thanh; Heckbert, Susan R.; Fitzpatrick, Annette L.; LoGerfo, James P.; Ngoc, Truong Le Van; Mokdad, Ali H.
2018-01-01
Objective To evaluate the association of salt consumption with blood pressure in Viet Nam, a developing country with a high level of salt consumption. Design and setting Analysis of a nationally representative sample of Vietnamese adults 25–65 years of age who were surveyed using the World Health Organization STEPwise approach to Surveillance protocol. Participants who reported acute illness, pregnancy, or current use of antihypertensive medications were excluded. Daily salt consumption was estimated from fasting mid-morning spot urine samples. Associations of salt consumption with systolic blood pressure and prevalent hypertension were assessed using adjusted linear and generalized linear models. Interaction terms were tested to assess differences by age, smoking, alcohol consumption, and rural/urban status. Results The analysis included 2,333 participants (mean age: 37 years, 46% male, 33% urban). The average estimated salt consumption was 10g/day. No associations of salt consumption with blood pressure or prevalent hypertension were observed at a national scale in men or women. The associations did not differ in subgroups defined by age, smoking, or alcohol consumption; however, associations differed between urban and rural participants (p-value for interaction of urban/rural status with salt consumption, p = 0.02), suggesting that higher salt consumption may be associated with higher systolic blood pressure in urban residents but lower systolic blood pressure in rural residents. Conclusions Although there was no evidence of an association at a national level, associations of salt consumption with blood pressure differed between urban and rural residents in Viet Nam. The reasons for this differential association are not clear, and given the large rate of rural to urban migration experienced in Viet Nam, this topic warrants further investigation. PMID:29346423
Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang
2015-04-01
The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.
Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying
2015-10-01
This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.
Anbarian, Mehrdad; Esmaeili, Hamed
2016-07-01
This study aimed to assess the effects of running-induced fatigue on plantar pressure parameters in novice runners with low and high medial longitudinal arch. Plantar pressure data from 42 novice runners (21 with high, and 21 with low arch) were collected before and after running-induced fatigue protocol during running at 3.3m/s along the Footscan(®) platform. Peak plantar pressure, peak force and force-time integral (impulse) were measured in ten anatomical zones. Relative time for foot roll-over phases and medio-lateral force ratio were calculated before and after the fatigue protocol. After the fatigue protocol, increases in the peak pressure under the first-third metatarsal zones and reduction under the fourth-fifth metatarsal regions were observed in the low arch individuals. In the high arch group, increases in peak pressure under the fourth-fifth metatarsal zones after the running-induced fatigue was observed. It could be concluded that running-induced fatigue had different effects on plantar pressure distribution pattern among novice runners with low and high medial longitudinal foot arch. These findings could provide some information related to several running injuries among individuals with different foot types. Copyright © 2016 Elsevier B.V. All rights reserved.
Receiver Statistics for Cognitive Radios in Dynamic Spectrum Access Networks
2012-02-28
SNR) are employed by many protocols and processes in direct-sequence ( DS ) spread-spectrum packet radio networks, including soft-decision decoding...adaptive modulation protocols, and power adjustment protocols. For DS spread spectrum, we have introduced and evaluated SNR estimators that employ...obtained during demodulation in a binary CDMA receiver. We investigated several methods to apply the proposed metric to the demodulator’s soft-decision
A nurse-led approach to preventing pressure ulcers.
Yap, Tracey L; Kennerly, Susan M
2011-01-01
This article discusses a nurse-led multidisciplinary approach that care providers can use to reduce pressure ulcers (PUs) within their organizations. Given the current understanding of PU etiology and prevention, evidence-based prevention protocols and pressure-relief strategies serve as critical foundational principles that must be applied to significantly influence PU prevalence and incidence. Because nursing plays an important role in rehabilitation facility management, nurses' expertise, leadership, and knowledge make nursing the most appropriate discipline to design protocols, implement innovative solutions, and lead the charge for PU prevention.
Li, Ingrid; Mackey, Martin G; Foley, Bridget; Pappas, Evangelos; Edwards, Kate; Chau, Josephine Y; Engelen, Lina; Voukelatos, Alexander; Whelan, Anna; Bauman, Adrian; Winkler, Elisabeth; Stamatakis, Emmanuel
2017-06-01
To examine the effects of different sit-stand protocols on work-time sitting and physical activity (PA) of office workers. Participants (n = 26, 77% women, mean age 42) were randomly allocated to usual sitting (control) or one of three sit-stand protocols (intervention) facilitated by height-adjustable workstations for a 4-week period between June and August 2015. Sitting, standing, and stepping time were assessed by inclinometry (activPAL); leisure-time physical activity (LTPA) by self-report. One-way analysis of covariance (ANCOVA) and post-hoc (Bonferroni) tests explored between-group differences. Compared with baseline, intervention groups reduced work sitting time by 113 minutes/8-hour workday (95% confidence interval [CI] [-147,-79]) and increased work standing time by 96 minutes/8-hour workday (95% CI [67,125]) without significantly impacting LTPA/sleep time. Sit-stand protocols facilitated by height-adjustable workstations appear to reduce office workers' sitting time without significant adverse effects on LTPA.
Temperature-Compensated Clock Skew Adjustment
Castillo-Secilla, Jose María; Palomares, Jose Manuel; Olivares, Joaquín
2013-01-01
This work analyzes several drift compensation mechanisms in wireless sensor networks (WSN). Temperature is an environmental factor that greatly affects oscillators shipped in every WSN mote. This behavior creates the need of improving drift compensation mechanisms in synchronization protocols. Using the Flooding Time Synchronization Protocol (FTSP), this work demonstrates that crystal oscillators are affected by temperature variations. Thus, the influence of temperature provokes a low performance of FTSP in changing conditions of temperature. This article proposes an innovative correction factor that minimizes the impact of temperature in the clock skew. By means of this factor, two new mechanisms are proposed in this paper: the Adjusted Temperature (AT) and the Advanced Adjusted Temperature (A2T). These mechanisms have been combined with FTSP to produce AT-FTSP and A2T-FTSP Both have been tested in a network of TelosB motes running TinyOS. Results show that both AT-FTSP and A2T-FTSP improve the average synchronization errors compared to FTSP and other temperature-compensated protocols (Environment-Aware Clock Skew Estimation and Synchronization for WSN (EACS) and Temperature Compensated Time Synchronization (TCTS)). PMID:23966192
McGowan, Amy; Silvestri, Giuliana; Moore, Evelyn; Silvestri, Vittorio; Patterson, Christopher C; Maxwell, Alexander P; McKay, Gareth J
2014-12-18
To evaluate the relationship between retinal vascular caliber (RVC), iris color, and age-related macular degeneration (AMD) in elderly Irish nuns. Data from 1233 participants in the cross-sectional observational Irish Nun Eye Study were assessed from digital photographs with a standardized protocol using computer-assisted software. Macular images were graded according to the modified Wisconsin Age-related Maculopathy Grading System. Regression models were used to assess associations, adjusting for age, mean arterial blood pressure, body mass index, refraction, and fellow RVC. In total, 1122 (91%) participants had gradable retinal images of sufficient quality for vessel assessment (mean age: 76.3 years [range, 56-100 years]). In an unadjusted analysis, we found some support for a previous finding that individuals with blue iris color had narrower retinal venules compared to those with brown iris color (P < 0.05), but this was no longer significant after adjustment. Age-related macular degeneration status was categorized as no AMD, any AMD, and late AMD only. Individuals with any AMD (early or late AMD) had significantly narrower arterioles and venules compared to those with no AMD in an unadjusted analysis, but this was no longer significant after adjustment. A nonsignificant reduced risk of any AMD or late AMD only was observed in association with brown compared to blue iris color, in both unadjusted and adjusted analyses. Retinal vascular caliber was not significantly associated with iris color or early/late AMD after adjustment for confounders. A lower but nonsignificant AMD risk was observed in those with brown compared to blue iris color. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Pressure-flow specificity of inspiratory muscle training.
Tzelepis, G E; Vega, D L; Cohen, M E; Fulambarker, A M; Patel, K K; McCool, F D
1994-08-01
The inspiratory muscles (IM) can be trained by having a subject breathe through inspiratory resistive loads or by use of unloaded hyperpnea. These disparate training protocols are characterized by high inspiratory pressure (force) or high inspiratory flow (velocity), respectively. We tested the hypothesis that the posttraining improvements in IM pressure or flow performance are specific to training protocols in a way that is similar to force-velocity specificity of skeletal muscle training. IM training was accomplished in 15 normal subjects by use of three protocols: high inspiratory pressure-no flow (group A, n = 5), low inspiratory pressure-high flow (group B, n = 5), and intermediate inspiratory pressure and flow (group C, n = 5). A control group (n = 4) did no training. Before and after training, we measured esophageal pressure (Pes) and inspiratory flow (VI) during single maximal inspiratory efforts against a range of external resistances including an occluded airway. Efforts originated below relaxation volume (Vrel), and peak Pes and VI were measured at Vrel. Isovolume maximal Pes-VI plots were constructed to assess maximal inspiratory pressure-flow performance. Group A (pressure training) performed 30 maximal static inspiratory maneuvers at Vrel daily, group B (flow training) performed 30 sets of three maximal inspiratory maneuvers with no added external resistance daily, and group C (intermediate training) performed 30 maximal inspiratory efforts on a midrange external resistance (7 mm ID) daily. Subjects trained 5 days/wk for 6 wk. Data analysis included comparison of posttraining Pes-VI slopes among training groups.(ABSTRACT TRUNCATED AT 250 WORDS)
Automatic control of pressure support for ventilator weaning in surgical intensive care patients.
Schädler, Dirk; Engel, Christoph; Elke, Gunnar; Pulletz, Sven; Haake, Nils; Frerichs, Inéz; Zick, Günther; Scholz, Jens; Weiler, Norbert
2012-03-15
Despite its ability to reduce overall ventilation time, protocol-guided weaning from mechanical ventilation is not routinely used in daily clinical practice. Clinical implementation of weaning protocols could be facilitated by integration of knowledge-based, closed-loop controlled protocols into respirators. To determine whether automated weaning decreases overall ventilation time compared with weaning based on a standardized written protocol in an unselected surgical patient population. In this prospective controlled trial patients ventilated for longer than 9 hours were randomly allocated to receive either weaning with automatic control of pressure support ventilation (automated-weaning group) or weaning based on a standardized written protocol (control group) using the same ventilation mode. The primary end point of the study was overall ventilation time. Overall ventilation time (median [25th and 75th percentile]) did not significantly differ between the automated-weaning (31 [19-101] h; n = 150) and control groups (39 [20-118] h; n = 150; P = 0.178). Patients who underwent cardiac surgery (n = 132) exhibited significantly shorter overall ventilation times in the automated-weaning (24 [18-57] h) than in the control group (35 [20-93] h; P = 0.035). The automated-weaning group exhibited shorter ventilation times until the first spontaneous breathing trial (1 [0-15] vs. 9 [1-51] h; P = 0.001) and a trend toward fewer tracheostomies (17 vs. 28; P = 0.075). Overall ventilation times did not significantly differ between weaning using automatic control of pressure support ventilation and weaning based on a standardized written protocol. Patients after cardiac surgery may benefit from automated weaning. Implementation of additional control variables besides the level of pressure support may further improve automated-weaning systems. Clinical trial registered with www.clinicaltrials.gov (NCT 00445289).
Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang
2014-02-01
The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.
Grim, Clarence E; Grim, Carlene M
2008-08-01
We have tested two home blood pressure monitors made by the HoMedics, Inc., 300 Pontiac Trail, Commerce Township, Michigan 48390, USA, using the European Society of Hypertension International Protocol. Both failed and we believe it is important to get this into the literature quickly to protect patients and practitioners.
Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang
2012-02-01
The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.
Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang
2014-06-01
The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.
Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang
2016-08-01
This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.
Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang
2017-08-01
The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.
Bialosky, Joel E.; Robinson, Michael E.
2014-01-01
Background Cluster analysis can be used to identify individuals similar in profile based on response to multiple pain sensitivity measures. There are limited investigations into how empirically derived pain sensitivity subgroups influence clinical outcomes for individuals with spine pain. Objective The purposes of this study were: (1) to investigate empirically derived subgroups based on pressure and thermal pain sensitivity in individuals with spine pain and (2) to examine subgroup influence on 2-week clinical pain intensity and disability outcomes. Design A secondary analysis of data from 2 randomized trials was conducted. Methods Baseline and 2-week outcome data from 157 participants with low back pain (n=110) and neck pain (n=47) were examined. Participants completed demographic, psychological, and clinical information and were assessed using pain sensitivity protocols, including pressure (suprathreshold pressure pain) and thermal pain sensitivity (thermal heat threshold and tolerance, suprathreshold heat pain, temporal summation). A hierarchical agglomerative cluster analysis was used to create subgroups based on pain sensitivity responses. Differences in data for baseline variables, clinical pain intensity, and disability were examined. Results Three pain sensitivity cluster groups were derived: low pain sensitivity, high thermal static sensitivity, and high pressure and thermal dynamic sensitivity. There were differences in the proportion of individuals meeting a 30% change in pain intensity, where fewer individuals within the high pressure and thermal dynamic sensitivity group (adjusted odds ratio=0.3; 95% confidence interval=0.1, 0.8) achieved successful outcomes. Limitations Only 2-week outcomes are reported. Conclusions Distinct pain sensitivity cluster groups for individuals with spine pain were identified, with the high pressure and thermal dynamic sensitivity group showing worse clinical outcome for pain intensity. Future studies should aim to confirm these findings. PMID:24764070
Hansson, L; Zanchetti, A
1994-09-01
The Hypertension Optimal Treatment (HOT) Study is a prospective, randomized, multicenter trial being conducted in 26 countries. Its main aim is to evaluate the relationship between three levels of target diastolic blood pressure (< or = 90, < or = 85 or < or = 80 mmHg) and cardiovascular morbidity and mortality in hypertensive patients. In addition, the study will examine the effects on morbidity and mortality of a low dose, 75 mg daily, of acetylsalicylic acid (ASA, aspirin) or placebo. In the HOT Study, basic antihypertensive treatment is initiated with the calcium antagonist felodipine at a dose of 5 mg daily. If target blood pressure is not reached, additional antihypertensive therapy with either an angiotensin converting enzyme (ACE) inhibitor or a beta-adrenoceptor blocking agent is given. Further dosage adjustments are made in accordance with a set protocol. As a fifth and final step, a diuretic may be added. Inclusion of patients was stopped on April 30, 1994. At that time 19,196 patients had been randomized. There were 9,055 (47%) women and 10,141 (53%) men with an average age of 61.5 +/- 7.5 (SD) years. At enrollment, 52% of patients were receiving antihypertensive treatment. These patients entered a wash-out period of at least 2 weeks before randomization. The average randomization blood pressure in untreated patients was 169 +/- 14/106 +/- 3 mmHg and in the treated patients 170 +/- 14/105 +/- 3 mmHg. On August 15, 1994, blood pressure data were available for 14,710 and 10,275 patients, who had completed 3 and 6 months treatment, respectively. The average reduction in diastolic blood pressure was 22 mmHg after 6 months.(ABSTRACT TRUNCATED AT 250 WORDS)
Hashimoto, Tomomi; Takase, Hiroyuki; Okado, Tateo; Sugiura, Tomonori; Yamashita, Sumiyo; Kimura, Genjiro; Ohte, Nobuyuki; Dohi, Yasuaki
2016-08-01
The close association between dietary salt and hypertension is well established. However, previous studies generally assessed salt intake without adjustment for body weight. Herein, we investigated the significance of body weight-adjusted salt intake in the general population. The present cross-sectional study included 7629 participants from our yearly physical checkup program, and their salt intake was assessed using a spot urine test to estimate 24-hour urinary salt excretion. Total salt intake increased with increasing body weight. Body weight-adjusted salt intake was greater in participants with hypertension than in those without hypertension. Systolic blood pressure, estimated glomerular filtration rate, and urinary albumin were independently correlated with body weight-adjusted salt intake after adjustment for possible cardiovascular risk factors. Excessive body weight-adjusted salt intake could be related to an increase in blood pressure and hypertensive organ damage. Adjustment for body weight might therefore provide clinically important information when assessing individual salt intake. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Comparison of two ways of altering carpal tunnel pressure with ultrasound surface wave elastography.
Cheng, Yu-Shiuan; Zhou, Boran; Kubo, Kazutoshi; An, Kai-Nan; Moran, Steven L; Amadio, Peter C; Zhang, Xiaoming; Zhao, Chunfeng
2018-06-06
Higher carpal tunnel pressure is related to the development of carpal tunnel syndrome. Currently, the measurement of carpal tunnel pressure is invasive and therefore, a noninvasive technique is needed. We previously demonstrated that speed of wave propagation through a tendon in the carpal tunnel measured by ultrasound elastography could be used as an indicator of carpal tunnel pressure in a cadaveric model, in which a balloon had to be inserted into the carpal tunnel to adjust the carpal tunnel pressure. However, the method for adjusting the carpal tunnel pressure in the cadaveric model is not applicable for the in vivo model. The objective of this study was to utilize a different technique to adjust carpal tunnel pressure via pressing the palm and to validate it with ultrasound surface wave elastography in a human cadaveric model. The outcome was also compared with a previous balloon insertion technique. Results showed that wave speed of intra-carpal tunnel tendon and the ratio of wave speed of intra-and outer-carpal tunnel tendons increased linearly with carpal tunnel pressure. Moreover, wave speed of intra carpal tunnel tendon via both ways of altering carpal tunnel pressure showed similar results with high correlation. Therefore, it was concluded that the technique of pressing the palm can be used to adjust carpal tunnel pressure, and pressure changes can be detected via ultrasound surface wave elastography in an ex vivo model. Future studies will utilize this technique in vivo to validate the usefulness of ultrasound surface wave elastography for measuring carpal tunnel pressure. Copyright © 2018 Elsevier Ltd. All rights reserved.
Controlled differential pressure system for an enhanced fluid blending apparatus
Hallman, Jr., Russell Louis
2009-02-24
A system and method for producing a controlled blend of two or more fluids. Thermally-induced permeation through a permeable tube is used to mix a first fluid from outside the tube with a second fluid flowing through the tube. Mixture ratios may be controlled by adjusting the temperature of the first fluid or by adjusting the pressure drop through the permeable tube. The combination of a back pressure control valve and a differential regulator is used to control the output pressure of the blended fluid. The combination of the back pressure control valve and differential regulator provides superior flow control of the second dry gas. A valve manifold system may be used to mix multiple fluids, and to adjust the volume of blended fluid produced, and to further modify the mixture ratio.
Oral intradialytic nutritional supplement use and mortality in hemodialysis patients.
Weiner, Daniel E; Tighiouart, Hocine; Ladik, Vladimir; Meyer, Klemens B; Zager, Philip G; Johnson, Douglas S
2014-02-01
Hemodialysis patients have high mortality rates, potentially reflecting underlying comorbid conditions and ongoing catabolism. Intradialytic oral nutritional supplements may reduce this risk. Retrospective propensity-matched cohort. Maintenance hemodialysis patients treated at Dialysis Clinic Inc facilities who were initiated on a nutritional supplement protocol in September to October 2010 were matched using a propensity score to patients at facilities at which the protocol was not used. Prescription of the protocol, whereby hemodialysis patients with serum albumin levels ≤3.5g/dL would initiate oral protein supplementation during the dialysis procedure. Sensitivity analyses matched on actual supplement intake during the first 3 study months. Covariates included patient and facility characteristics, which were used to develop the propensity scores and adjust multivariable models. All-cause mortality, ascertained though March 2012. Of 6,453 eligible patients in 101 eligible hemodialysis facilities, the protocol was prescribed to 2,700, and 1,278 of these were propensity matched to controls. Mean age was 61 ± 15 (SD) years and median dialysis vintage was 34 months. There were 258 deaths among protocol assignees versus 310 among matched controls during a mean follow-up of 14 months. In matched analyses, protocol prescription was associated with a 29% reduction in the hazard of all-cause mortality (HR, 0.71; 95% CI, 0.58-0.86); adjustment had minimal impact on models. In time-dependent models incorporating change in albumin level, protocol status remained significant but was attenuated in models incorporating a 30-day lag. Similar results were seen in sensitivity analyses of 439 patients receiving supplements who were propensity-matched to controls, with 116 deaths among supplement users versus 140 among controls (HR, 0.79; 95% CI, 0.60-1.05), achieving statistical significance in adjusted models. Observational design, potential residual confounding. Prescription of an oral nutritional supplement protocol and use of oral protein nutritional supplements during hemodialysis are associated with reduced mortality among in-center maintenance hemodialysis patients, an effect likely not mediated by change in serum albumin levels. Copyright © 2014 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Adjustable valves in normal-pressure hydrocephalus: a retrospective study of 218 patients.
Zemack, Göran; Romner, Bertil
2002-12-01
We sought to assess the value of adjusting shunt valve opening pressure, complications, and outcomes with the use of an adjustable shunt valve in the treatment of patients with normal-pressure hydrocephalus (NPH). In a single-center retrospective study, 231 adjustable valves (range, 30-200 mm H(2)O) were the first shunt implantations in 147 patients with idiopathic NPH (INPH) and 71 patients with secondary NPH (SNPH). The effect of adjustment on gait disturbance, cognitive impairment, urinary incontinence and other symptoms were evaluated, and an improvement index was created. In the INPH group, 138 adjustments were performed in 49.0% of the patients (average, 0.94 adjustments/patient). For the SNPH group, 49 adjustments were performed in 32.4% of the patients (average, 0.69 adjustments/patient). The reasons for adjustment were overdrainage in 48 patients (25.7%), underdrainage in 98 patients (52.4%), subdural hematoma in 37 patients (19.8%), and other reasons in 2 patients (2.1%). Clinical status improved after 56 (49.1%) of all 114 adjustments, whereas 23 (42.6%) of 54 minor (< or =20 mm H2O) and 33 (66.0%) of 50 larger adjustments improved the patient's clinical status. The correlation of the improvement index with the size of the individual adjustments was not significant. Complications occurred in 43 (19.7%) of 218 patients, valve malfunction occurred in 3 patients (1.3%), infection occurred in 14 patients (6.4%), and nontraumatic subdural effusion occurred in 15 patients (6.9%; 8 were treated by adjustment alone). The 5-year shunt survival rate was 80.2%. Outcomes were excellent or good in 71 (78.9%) of 90 patients with INPH and in 30 (69.8%) of 43 patients with SNPH. Noninvasive, particularly consecutive, minor or single larger adjustments to the valve opening pressure can further improve outcome in patients with NPH who undergo shunting.
Evaluation of the Stress Adjustment and Adaptation Model among Families Reporting Economic Pressure
ERIC Educational Resources Information Center
Vandsburger, Etty; Biggerstaff, Marilyn A.
2004-01-01
This research evaluates the Stress Adjustment and Adaptation Model (double ABCX model) examining the effects resiliency resources on family functioning when families experience economic pressure. Families (N = 128) with incomes at or below the poverty line from a rural area of a southern state completed measures of perceived economic pressure,…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-08
... using the NASDAQ Information Exchange (``QIX'') protocol,\\7\\ (ii) Financial Information Exchange (``FIX'') trading ports,\\8\\ and (iii) ports using other trading telecommunications protocols.\\9\\ Beginning July 1... because market participants may readily adjust their order routing practices, NASDAQ believes that the...
Toward a single nursery protocol for oak seedlings
Paul P. Kormanik; Shi-Jean S. Sung; T.L. Kormanik
1994-01-01
After a soil fertility baseline had been determined for the Georgia Forestry Commission's (GFC) Morgan Nursery, and single nursery protocol consistently produced high quality oak seedlings. The fertility baseline developed at the Institute of Tree Root Biology's Whitehall Experimental Nursery and adjusted for three GFC nurseries has a background target level...
Chen, Qi; Lei, Lei; Li, Yan; Wang, Ji-Guang
2017-10-01
The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor YuWell YE690A for blood pressure measurement according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese (12 women, 44.2 years of mean age) using a mercury sphygmomanometer (two observers) and the YE690A device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The YuWell YE690A device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 79/99, 96/99, and 97/99, respectively, for systolic blood pressure and 72/99, 95/99, and 98/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Thirty-one and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant for systolic and two participants for diastolic blood pressure had all the three device-observer comparisons greater than 5 mmHg. The YuWell blood pressure monitor YE690A has passed the requirements of the International Protocol revision 2010 and hence can be recommended for blood pressure measurement in adults.
Automated Weaning from Mechanical Ventilation after Off-Pump Coronary Artery Bypass Grafting.
Fot, Evgenia V; Izotova, Natalia N; Yudina, Angelika S; Smetkin, Aleksei A; Kuzkov, Vsevolod V; Kirov, Mikhail Y
2017-01-01
The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning ( n = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning ( n = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO 2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group ( p < 0.01). The average time until tracheal extubation did not differ in the automated weaning and the protocolized weaning groups: 193 (115-309) and 197 (158-253) min, respectively, but increased to 290 (210-411) min in the standard weaning group. The automated weaning system after off-pump coronary surgery might provide postoperative ventilation in a more protective way, reduces the workload on medical staff, and does not prolong the duration of weaning from ventilator. The use of automated or protocolized weaning can reduce the duration of postoperative mechanical ventilation in comparison with non-protocolized weaning based on the physician's decision.
Bilo, Grzegorz; Zorzi, Cristina; Ochoa Munera, Juan E; Torlasco, Camilla; Giuli, Valentina; Parati, Gianfranco
2015-10-01
The present study aimed to evaluate the accuracy of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults (11 women, mean age 63.5±11.9 years) using a mercury sphygmomanometer (two observers) and the Somnotouch-NIBP device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the validation requirements were fulfilled. The Somnotouch-NIBP device fulfilled the requirements of the part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 75/99, 90/99, and 96/99, respectively, for systolic blood pressure and 90/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-seven and 31 participants had at least two of the three device-observers differences less than or equal to 5 mmHg for systolic and diastolic blood pressure, respectively. All three device-observer differences were greater than 5 mmHg in two participants for systolic and in one participant for diastolic blood pressure. The Somnotouch-NIBP noninvasive continuous blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure monitoring in adults, at least under conditions corresponding to those investigated in our study.
Prebreathe Protocol for Extravehicular Activity Technical Consultation Report
NASA Technical Reports Server (NTRS)
Ross, Jerry; Duncan, Michael
2008-01-01
In the performance of EVA by that National Aeronautics and Space Administration (NASA) astronauts, there exists a risk of DCS as the suit pressure is reduced to 4.3 pounds per square inch, absolute (psia) from the International Space Station (ISS) pressure of 14.7 psia. Several DCS-preventive procedures have been developed and implemented. Each of these procedures involve the use of oxygen (O2) prebreathe to effectively washout tissue nitrogen (N2).The management of the ISS Programs convened an expert independent peer review Team to conduct a review of the Decompression Sickness (DCS) risks associated with the Extra Vehicular Activity (EVA) Campout Prebreathe (PB) protocol for its consideration for use on future missions. The major findings and recommendations of the expert panel are: There is no direct experimental data to confirm the potential DCS risks of the Campout PB protocol. However, based on model data, statistical probability, physiology, and information derived from similar PB protocols, there is no compelling evidence to suggest that the Campout PB protocol is less safe than the other NASA approved PB protocols.
Woodhouse, Marjolein; Worsley, Peter R; Voegeli, David; Schoonhoven, Lisette; Bader, Dan L
2015-02-01
Individuals who have reduced mobility are at risk of developing pressure ulcers if they are subjected to sustained static postures. To reduce this risk, clinical guidelines advocate healthcare professionals reposition patients regularly. Automated tilting mechanisms have recently been introduced to provide periodic repositioning. This study compared the performance of such a prototype mattress to conventional manual repositioning. Ten healthy participants (7 male and 3 female, aged 23-66 years) were recruited to compare the effects of an automated tilting mattress to standard manual repositioning, using the 30° tilt. Measures during the tilting protocols (supine, right and left tilt) included comfort and safety scores, interface pressures, inclinometer angles and transcutaneous gas tensions (sacrum and shoulder). Data from these outcomes were compared between each protocol. Results indicated no significant differences for either interface pressures or transcutaneous gas responses between the two protocols (P>0.05 in both cases). Indeed a small proportion of participants (~30%) exhibited changes in transcutaneous oxygen and carbon dioxide values in the shoulder during a right tilt for both protocols. The tilt angles at the sternum and the pelvis were significantly less in the automated tilt compared to the manual tilt (mean difference=9.4-11.5°, P<0.001). Participants reported similar comfort scores for both protocols, although perceived safety was reduced on the prototype mattress. Although further studies are required to assess its performance in maintaining tissue viability, an automated tilting mattress offers the ability to periodically reposition vulnerable individuals, with potential economic savings to health services. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Waligora, J. M.; Horrigan, D. J., Jr.; Conkin, J.; Hadley, A. T., III
1984-01-01
Three test series involving 173-man tess were conducted to define and verify a pre-extravehicular activity (EVA) denitrogenation procedure that would provide acceptable protection against altitude decompression sickness while minimizing the required duration of oxygen (O2) prebreathe in the suit prior to EVA. The tests also addressed the safety, in terms of incidence of decompression sickness, of conducting EVA's on consecutive days rather than on alternate days. The tests were conducted in an altitude chamber, subjects were selected as representative of the astronaut population, and EVA periods were simulated by reducing the chamber pressure to suit pressure while the subjects breathed O2 with masks and worked at EVA representative work rates. A higher than anticipated incidence of both venous bubbles (55%) and symptoms (26%) was measured following all denitrogenation protocols in this test. For the most part, symptoms were very minor and stabilized, diminished, or disappeared in the six-hour tests. Instances of clear, possible, or potential systemic symptoms were encountered only after use of the unmodified 10.2 psi protocol and not after the modified 10.2 psi protocol, the 3.5-hour O2 prebreathed protocol, or the 4.0-hour O2 prebreathe protocol. The high incidence of symptoms is ascribed to the type and duration of exercise and the sensitivity of the reporting technique to minor symptoms. Repeated EVA exposures after only 17 hours did not increase symptom or bubble incidence.
Controlled breathing protocols probe human autonomic cardiovascular rhythms
NASA Technical Reports Server (NTRS)
Cooke, W. H.; Cox, J. F.; Diedrich, A. M.; Taylor, J. A.; Beightol, L. A.; Ames, J. E. 4th; Hoag, J. B.; Seidel, H.; Eckberg, D. L.
1998-01-01
The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Gases), 2.5 (Test Pressures and Burner Adjustments), 2.6 (Static Pressure and Air Flow Adjustments), 2... pressure, as specified in Section 2.5.1 of ANSI Standard Z21.47-1998, (Incorporated by reference, see § 431... thermal efficiency test), 41 (Initial Test Conditions), 42 (Combustion Test—Burner and Furnace), 43.2...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Gases), 2.5 (Test Pressures and Burner Adjustments), 2.6 (Static Pressure and Air Flow Adjustments), 2... pressure, as specified in Section 2.5.1 of ANSI Standard Z21.47-1998, (Incorporated by reference, see § 431... thermal efficiency test), 41 (Initial Test Conditions), 42 (Combustion Test—Burner and Furnace), 43.2...
Prosthetic occlusive device for an internal passageway
NASA Technical Reports Server (NTRS)
Tenney, J. B., Jr. (Inventor)
1983-01-01
An occlusive device is disclosed for surgical implant to occlude the lumen of an internal organ. The device includes a cuff having a backing collar and two isolated cuff chambers. The fluid pressure of one chamber is regulated by a pump/valve reservoir unit. The other chamber is unregulated in pressure but its fluid volume is adjusted by removing or adding fluid to a septum/reservoir by means of a hypodermic needle. Pressure changes are transmitted between the two cuff chambers via faying surfaces which are sufficiently large in contact area and thin as to transmit pressure generally without attenuation. By adjusting the fluid volume of the septum, the operating pressure of the device may be adjusted to accommodate tubular organs of different diameter sizes as well as to compensate for changes in the organ following implant without reoperation.
Watret, L
1999-10-01
The Glasgow Acute Clinical Audit Sub-Committee on Pressure Sores has previously carried out studies of incidence of pressure ulcers in the medical directorates and case-mix-adjusted the figures for length of hospital stay and risk assessment score. Case-mix classification is 'classification of people or treatment placed into groups using characteristics associated with condition, treatment or outcome that can be used to predict need, resource, use of outcomes'. In this instance, crude pressure ulcer incidence figures may be adjusted for length of hospital stay and pressure sore risk assessment score, and stratified into groups, which allows like to be compared with like. The value in case-mix-adjusted figures lies in repeating the exercise, thus determining the trend for individual areas and assessing whether improvement in the quality of care is being achieved. This is more positive than creation of 'league tables' comparing simultaneous studies in a number of areas. The figures showed that there was no statistically significant difference between surgical directorates in trusts with regard to risk assessment scores and length of hospital stay. Gathering data on the incidence of pressure ulcer development allows us to identify where new sores are occurring, but does not critically analyse the nursing intervention taken in individual cases, which identifies preventive strategies. The Glasgow group's primary aim was to gather data on case-mix-adjusted incidence of pressure damage; the secondary objectives were to scrutinize the data to gather more general information on intrinsic and extrinsic factors which may predispose to pressure ulcer development. The study was carried out in the surgical directorate. Findings showed that incidence was low (1.1%), with the majority of sores being superficial. There was a correlation between pressure ulcer development and incontinence, evidence of under-utilization of moving and handling aids for prevention of pressure ulcers, and a need for greater collaboration between nursing staff and dietitians. All patients had access to pressure-reducing surfaces, with cut-foam pressure-reducing mattresses with vapour-permeable covers on all beds. Dynamic systems were available if the primary nurse identified a need for them.
Universal Barenco quantum gates via a tunable noncollinear interaction
NASA Astrophysics Data System (ADS)
Shi, Xiao-Feng
2018-03-01
The Barenco gate (B ) is a type of two-qubit quantum gate based on which alone universal quantum computation can be achieved. Each B is characterized by three angles (α , θ , and ϕ ), though it works in a two-qubit Hilbert space. Here we design B via a noncollinear interaction V | r1r2>< r1r3|+H .c . , where | ri> is a state that can be excited from a qubit state and V is adjustable. We present two protocols for B . The first (second) protocol consists of two (six) pulses and one (two) wait period(s), where the former causes rotations between qubit states and excited states, and the latter induces gate transformation via the noncollinear interaction. In the first protocol, the variable ϕ can be tuned by varying the phases of external controls, and the other two variables α and θ , tunable via adjustment of the wait duration, have a linear dependence on each other. Meanwhile, the first protocol can give rise to cnot and controlled-y gates. In the second protocol, α ,θ , and ϕ can be varied by changing the interaction amplitudes and wait durations, and the latter two are dependent on α nonlinearly. Both protocols can also lead to another universal gate when {α ,ϕ }={1 /4 ,1 /2 }π with appropriate parameters. Implementation of these universal gates is analyzed based on the van der Waals interaction of neutral Rydberg atoms.
MAC Protocol for Ad Hoc Networks Using a Genetic Algorithm
Elizarraras, Omar; Panduro, Marco; Méndez, Aldo L.
2014-01-01
The problem of obtaining the transmission rate in an ad hoc network consists in adjusting the power of each node to ensure the signal to interference ratio (SIR) and the energy required to transmit from one node to another is obtained at the same time. Therefore, an optimal transmission rate for each node in a medium access control (MAC) protocol based on CSMA-CDMA (carrier sense multiple access-code division multiple access) for ad hoc networks can be obtained using evolutionary optimization. This work proposes a genetic algorithm for the transmission rate election considering a perfect power control, and our proposition achieves improvement of 10% compared with the scheme that handles the handshaking phase to adjust the transmission rate. Furthermore, this paper proposes a genetic algorithm that solves the problem of power combining, interference, data rate, and energy ensuring the signal to interference ratio in an ad hoc network. The result of the proposed genetic algorithm has a better performance (15%) compared to the CSMA-CDMA protocol without optimizing. Therefore, we show by simulation the effectiveness of the proposed protocol in terms of the throughput. PMID:25140339
Jiang, Jieying; Liu, Mengling; Parvez, Faruque; Wang, Binhuan; Wu, Fen; Eunus, Mahbub; Bangalore, Sripal; Newman, Jonathan D; Ahmed, Alauddin; Islam, Tariqul; Rakibuz-Zaman, Muhammad; Hasan, Rabiul; Sarwar, Golam; Levy, Diane; Slavkovich, Vesna; Argos, Maria; Scannell Bryan, Molly; Farzan, Shohreh F; Hayes, Richard B; Graziano, Joseph H; Ahsan, Habibul; Chen, Yu
2015-08-01
Cross-sectional studies have shown associations between arsenic exposure and prevalence of high blood pressure; however, studies examining the relationship of arsenic exposure with longitudinal changes in blood pressure are lacking. We evaluated associations of arsenic exposure in relation to longitudinal change in blood pressure in 10,853 participants in the Health Effects of Arsenic Longitudinal Study (HEALS). Arsenic was measured in well water and in urine samples at baseline and in urine samples every 2 years after baseline. Mixed-effect models were used to estimate the association of baseline well and urinary creatinine-adjusted arsenic with annual change in blood pressure during follow-up (median, 6.7 years). In the HEALS population, the median water arsenic concentration at baseline was 62 μg/L. Individuals in the highest quartile of baseline water arsenic or urinary creatinine-adjusted arsenic had a greater annual increase in systolic blood pressure compared with those in the reference group (β = 0.48 mmHg/year; 95% CI: 0.35, 0.61, and β = 0.43 mmHg/year; 95% CI: 0.29, 0.56 for water arsenic and urinary creatinine-adjusted arsenic, respectively) in fully adjusted models. Likewise, individuals in the highest quartile of baseline arsenic exposure had a greater annual increase in diastolic blood pressure for water arsenic and urinary creatinine-adjusted arsenic, (β = 0.39 mmHg/year; 95% CI: 0.30, 0.49, and β = 0.45 mmHg/year; 95% CI: 0.36, 0.55, respectively) compared with those in the lowest quartile. Our findings suggest that long-term arsenic exposure may accelerate age-related increases in blood pressure. These findings may help explain associations between arsenic exposure and cardiovascular disease.
Variable pressure power cycle and control system
Goldsberry, Fred L.
1984-11-27
A variable pressure power cycle and control system that is adjustable to a variable heat source is disclosed. The power cycle adjusts itself to the heat source so that a minimal temperature difference is maintained between the heat source fluid and the power cycle working fluid, thereby substantially matching the thermodynamic envelope of the power cycle to the thermodynamic envelope of the heat source. Adjustments are made by sensing the inlet temperature of the heat source fluid and then setting a superheated vapor temperature and pressure to achieve a minimum temperature difference between the heat source fluid and the working fluid.
Rickards, Caroline A; Sprick, Justin D; Colby, Hannah B; Kay, Victoria L; Tzeng, Yu-Chieh
2015-04-01
We tested the hypothesis that transmission of arterial pressure to brain tissue oxygenation is low under conditions of arterial pressure instability. Two experimental models of hemodynamic instability were used in healthy human volunteers; (1) oscillatory lower body negative pressure (OLBNP) (N = 8; 5 male, 3 female), and; (2) maximal LBNP to presyncope (N = 21; 13 male, 8 female). Mean arterial pressure (MAP), middle cerebral artery velocity (MCAv), and cerebral tissue oxygen saturation (ScO2) were measured non-invasively. For the OLBNP protocol, between 0 and -60 mmHg negative pressure was applied for 20 cycles at 0.05 Hz, then 20 cycles at 0.1 Hz. For the maximal LBNP protocol, progressive 5 min stages of chamber decompression were applied until the onset of presyncope. Spectral power of MAP, mean MCAv, and ScO2 were calculated within the VLF (0.04-0.07 Hz), and LF (0.07-0.2 Hz) ranges, and cross-spectral coherence was calculated for MAP-mean MCAv, MAP-ScO2, and mean MCAv-ScO2 at baseline, during each OLBNP protocol, and at the level prior to pre-syncope during maximal LBNP (sub-max). The key findings are (1) both 0.1 Hz OLBNP and sub-max LBNP elicited increases in LF power for MAP, mean MCAv, and ScO2 (p ≤ 0.08); (2) 0.05 Hz OLBNP increased VLF power in MAP and ScO2 only (p ≤ 0.06); (3) coherence between MAP-mean MCAv was consistently higher (≥0.71) compared with MAP-ScO2, and mean MCAv-ScO2 (≤0.43) during both OLBNP protocols, and sub-max LBNP (p ≤ 0.04). These data indicate high linearity between pressure and cerebral blood flow variations, but reduced linearity between cerebral tissue oxygenation and both arterial pressure and cerebral blood flow. Measuring arterial pressure variability may not always provide adequate information about the downstream effects on cerebral tissue oxygenation, the key end-point of interest for neuronal viability.
Pereira, Telmo; Maldonado, João
2005-11-01
To evaluate the performance of the Colson MAM BP 3AA1-2 oscillometric automatic blood pressure monitor according to the validation protocol of the European Society of Hypertension, testing its suitability for self-measurement of blood pressure. The performance of the device was assessed in relation to various clinical variables, including age, gender, body mass index, arm circumference and arterial stiffness. 33 subjects (15 men and 18 women), with a mean age of 47 +/- 10 years, were studied according to the procedures laid down in the European Society of Hypertension validation protocol. Sequential same-arm blood pressure measurements were made, alternating between a mercury standard and the automatic device. The differences among the test-control measurements were assessed and divided into categorization zones of 5, 10 and 15 mmHg discrepancy. Aortic pulse wave velocity was assessed in all subjects with a Complior device (Colson, Paris). The Colson MAM BP 3AA1-2 passed all three phases of the protocol for both systolic and diastolic blood pressure. The mean differences between the test and control measurements were -1.0 +/- 5.0 mmHg for systolic blood pressure and -1.1 +/- 4.1 mmHg for diastolic blood pressure. Both standard deviations are well below the 8 mmHg limit proposed by the Association for the Advancement of Medical Instrumentation. The predictive value of various clinical variables for the discrepancies was assessed by a regression model analysis, with no variable being found that independently undermined the performance of the monitor. In another regression analysis, we found a similar relation between test and control blood pressures and aortic pulse wave velocity, a widely recognized and validated index of target organ damage. These data show that the Colson MAM BP 3AA1-2 satisfies the quality requirements proposed by the European Society of Hypertension, demonstrating its suitability for inclusion in integrated programs of clinical surveillance based on self-measurement of blood pressure. The uniformity of its performance over a wide spectrum of clinical characteristics and the relation found with pulse wave velocity further reinforce its clinical validity.
NASA Technical Reports Server (NTRS)
Abercromby, Andrew F. J.; Conkin, Johnny; Gernhardt, Michael L.
2017-01-01
Exploration missions are expected to use variable pressure extravehicular activity (EVA) spacesuits as well as a spacecraft "exploration atmosphere" of 56.5 kPa (8.2 psia), 34% O2, both of which provide the possibility of reducing the oxygen prebreathe times necessary to reduce decompression sickness (DCS) risk. Previous modeling work predicted 8.4% DCS risk for an EVA beginning at the exploration atmosphere, followed by 15 minutes of in-suit O2 prebreathe, and 6 hours of EVA at 29.6 kPa (4.3 psia). In this study we model notional prebreathe protocols for a variable pressure suit where the exploration atmosphere is unavailable.
Comparison of Physiological and Perceptual Responses Between Continuous and Intermittent Cycling
Brasil, Roxana M.; Barreto, Ana C.; Nogueira, Leandro; Santos, Edil; Novaes, Jefferson S.; Reis, Victor M.
2011-01-01
The present study tested the hypothesis that the exercise protocol (continuous vs. intermittent) would affect the physiological response and the perception of effort during aquatic cycling. Each protocol was divided on four stages. Heart rate, arterial blood pressure, blood lactate concentration, central and peripheral rate of perceived exertion were collected in both protocols in aquatic cycling in 10 women (values are mean ± SD): age=32.8 ± 4.8 years; height=1.62 ± 0.05 cm; body mass=61.60 ± 5.19 kg; estimated body fat=27.13 ± 4.92%. Protocols were compared through two way ANOVA with Scheffé’s post-hoc test and the test of Mann- Whitney for rate of perceived exertion with α=0.05. No systematic and consistent differences in heart rate, arterial blood pressure, double product and blood lactate concentration were found between protocols. On the other hand, central rate of perceived exertion was significantly higher at stage four during continuous protocol compared with intermittent protocol (p=0.01), while the peripheral rate of perceived exertion presented higher values at stages three (p=0.02) and four (p=0.00) in the continuous protocol when compared to the results found in intermittent protocol. These findings suggest that although the aquatic cycling induces similar physiologic demands in both protocols, the rate of perceived exertion may vary according to the continuous vs. intermittent nature of the exercise. PMID:23487483
DOT National Transportation Integrated Search
2002-06-01
Two separate studies were accomplished to investigate human factors issues related to the use of lap belts. Human performance trials were conducted under two protocols to measure and assess: (1) seat belt tension adjustment during normal flight and e...
Cardiovascular responses to plyometric exercise are affected by workload in athletes.
Arazi, Hamid; Asadi, Abbas; Mahdavi, Seyed Amir; Nasiri, Seyed Omid Mirfalah
2014-01-01
With regard to blood pressure responses to plyometric exercise and decreasing blood pressure after exercise (post-exercise hypotension), the influence of different workloads of plyometric exercise on blood pressure is not clear. The purpose of this investigation was to examine the effects of a low, moderate and high workload of plyometric exercise on the post-exercise systolic (SBP) and diastolic blood pressure (DBP), heart rate (HR) and rate-pressure product (RPP) responses in athletes. TEN MALE ATHLETES (AGE: 22.6 ±0.5 years; height: 178.2 ±3.3 cm; and body mass: 75.2 ±2.8 kg) underwent PE protocols involving 5 × 10 reps (Low Workload - LW), 10 × 10 reps (Moderate Workload - MW), and 15 × 10 reps (High Workload - HW) depth jump exercise from a 50-cm box in 3 non-consecutive days. After each exercise session, SBP, DBP and HR were measured every 10 min for a period of 70 min. No significant differences were observed among post-exercise SBP and DBP when the protocols (LW, MW and HW) were compared. The MW and HW protocols showed greater increases in HR compared with LW. Also the HW indicated greater increases than LW in RPP at post-exercise (p < 0.05). All protocols increased SBP, HR and RPP responses at the 10(th) and 20(th) min of post-exercise. With regard to different workloads of plyometric exercise, HW condition indicated greater increases in HR and RPP and strength and conditioning professionals and athletes must keep in their mind that HW of plyometric exercise induces greater cardiovascular responses.
Cho, K; Tian, M; Lan, Y; Zhao, X; Yan, L L
2013-08-01
Few studies have been conducted on blood pressure monitors and their use at high altitude. This study is the first to evaluate the accuracy of an automatic blood pressure monitor in a high-altitude environment following a standard validation protocol. The Omron HEM-7201 upper arm blood pressure monitor was tested for accuracy in Lhasa, Tibet, China (3650 m above sea level) according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2). Thirty-three participants received 9-10 sequential blood pressure measurements alternating between a mercury sphygmomanometer and the device. The mean device-observer measurement difference was 1.0±5.9 mm Hg for systolic blood pressure (SBP) and -3.1±4.6 mm Hg for diastolic blood pressure (DBP). Of the 99 measurement pairs analyzed, 72, 90 and 97 device readings were within 5, 10 and 15 mm Hg, respectively, of the observer measurements for SBP, and 68, 92 and 99 readings for DBP. The number of participants with at least two out of three measurements within 5 mm Hg was 27 for SBP and 25 for DBP. Three participants had no measurements within 5 mm Hg for either SBP or DBP. As a result, the Omron HEM-7201 passes the ESH-IP2 validation criteria and can therefore be recommended for use in adults in this setting.
Chen, Can; Shang, Fujun; Wang, Jiepin; Chen, Jianghong; Ji, Na; Wan, Yi
2012-12-01
This study aimed to evaluate the performance of the iHealth BP3 upper-arm blood pressure monitor, which is designed for clinic use and self-measurement of blood pressure using Apple touch devices as an interface. The European Society of Hypertension International Protocol (ESH-IP) revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. Ninty-nine couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The 33 participants, age 47.1±12.3 years (age range 27-69 years) and arm circumference 30.0±4.4 cm, had a mean systolic blood pressure (SBP) of 143.9±27.4 mmHg and a mean diastolic blood pressure (DBP) of 90.1±18.3 mmHg. The device passed all of the requirements fulfilling the standards of the protocol, and the mean±SD device-observer difference was 2.8±4.2 mmHg for SBP and -0.4±3.5 mmHg for DBP. According to the results of the validation study on the basis of the ESH-IP revision 2010, the iHealth BP3 can be recommended for clinic use and self-measurement in an adult population. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Ibanez, Isabel; Khabouth, Jose; Khawaja, Salwa; Beaino, Layale; Asmar, Roland
2011-01-01
Four oscillometric devices for self-measurement of blood pressure (SBPM) were evaluated according to the European Society of Hypertension (ESH) international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP) at the brachial level, while the Omron R2 measures BP at the wrist level. The international protocol requires a total number of 33 subjects in which the validation is performed. The Omron M2 and Omron R2 were validated in 2009 according to the ESH international protocol, while the Omron M3 and Omron M6 were validated in 2010-2011 according to the 2010 ESH international protocol revision. The protocol procedures were followed precisely. All four tested devices passed the validation process. The mean differences between the device and mercury readings were 2.7 ± 5.0 and -1.4 ± 3.2 mmHg for systolic and diastolic BP, respectively, using the Omron M2 device, and 1.7 ± 3.2 and -0.9 ± 2.6 mmHg using the Omron M3, 1.6 ± 2.9 and -0.9 ± 2.5 mmHg using the Omron M6, and -1.1 ± 4.8 and -0.9 ± 4.3 mmHg using the Omron R2. Readings from the Omron M2, Omron M3, Omron M6, and Omron R2, differing by less than 5, 10, and 15 mmHg, fulfill the ESH international protocol and its 2010 revision requirements. Therefore, each of these four devices can be used by patients for SBPM.
Adjustable Tuning Spring for Bellows Pump
NASA Technical Reports Server (NTRS)
Green, G. L.; Tu Duc, D.; Hooper, S.
1985-01-01
Adjustable leaf spring increases maximum operating pressure of pump from 2 to over 60 psi (13 to over 400 kN/m2). Small commercial bellows pump using ac-powered electromagnet to vibrate bellows at mechanical resonance modified to operate over wider pressure range.
Martín-Láez, Rubén; Vázquez-Barquero, Alfonso
Despite the existence of published guidelines for more than a decade, there is still a substantial variation in the management of idiopathic normal pressure hydrocephalus due to its diagnostic and therapeutic complexity. The diagnostic and therapeutic protocol for the management of idiopathic normal pressure hydrocephalus in use at the Department of Neurosurgery of the University Hospital Marqués de Valdecilla is presented. The diagnostic process includes neuropsychological testing, phase contrast cine MRI, urodynamic evaluation, continuous intracranial pressure monitoring, cerebrospinal fluid hydrodynamics by means of lumbar infusion testing, and intra-abdominal pressure measurement. A patient is considered a surgical candidate if any of the following criteria is met: mean intracranial pressure >15mmHg, or B-waves present in >10% of overnight recording; pressure-volume index <15ml, or resistance to cerebrospinal fluid outflow (R OUT ) >4.5mmHg/ml/min in bolus infusion test; R OUT >12mmHg/ml/min, intracranial pressure >22mmHg, or high amplitude B-waves in the steady-state of the continuous rate infusion test; or a clinical response to high-volume cerebrospinal fluid withdrawal. The implementation of a diagnostic and therapeutic protocol for idiopathic normal pressure hydrocephalus management could improve various aspects of patient care. It could reduce variability in clinical practice, optimise the use of health resources, and help in identifying scientific uncertainty areas, in order to direct research efforts in a more appropriate way. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.
Cattet, Marc; Zedrosser, Andreas; Stenhouse, Gordon B.; Küker, Susanne; Evans, Alina L.; Arnemo, Jon M.
2017-01-01
We compared anesthetic features, blood parameters, and physiological responses to either medetomidine-tiletamine-zolazepam or dexmedetomidine-tiletamine-zolazepam using a double-blinded, randomized experimental design during 40 anesthetic events of free-ranging brown bears (Ursus arctos) either captured by helicopter in Sweden or by culvert trap in Canada. Induction was smooth and predictable with both anesthetic protocols. Induction time, the need for supplemental drugs to sustain anesthesia, and capture-related stress were analyzed using generalized linear models, but anesthetic protocol did not differentially affect these variables. Arterial blood gases and acid-base status, and physiological responses were examined using linear mixed models. We documented acidemia (pH of arterial blood < 7.35), hypoxemia (partial pressure of arterial oxygen < 80 mmHg), and hypercapnia (partial pressure of arterial carbon dioxide ≥ 45 mmHg) with both protocols. Arterial pH and oxygen partial pressure were similar between groups with the latter improving markedly after oxygen supplementation (p < 0.001). We documented dose-dependent effects of both anesthetic protocols on induction time and arterial oxygen partial pressure. The partial pressure of arterial carbon dioxide increased as respiratory rate increased with medetomidine-tiletamine-zolazepam, but not with dexmedetomidine-tiletamine-zolazepam, demonstrating a differential drug effect. Differences in heart rate, respiratory rate, and rectal temperature among bears could not be attributed to the anesthetic protocol. Heart rate increased with increasing rectal temperature (p < 0.001) and ordinal day of capture (p = 0.002). Respiratory rate was significantly higher in bears captured by helicopter in Sweden than in bears captured by culvert trap in Canada (p < 0.001). Rectal temperature significantly decreased over time (p ≤ 0.05). Overall, we did not find any benefit of using dexmedetomidine-tiletamine-zolazepam instead of medetomidine-tiletamine-zolazepam in the anesthesia of brown bears. Both drug combinations appeared to be safe and reliable for the anesthesia of free-ranging brown bears captured by helicopter or by culvert trap. PMID:28118413
Heart rate, blood pressure and repolarization effects of an energy drink as compared to coffee.
Brothers, R Matthew; Christmas, Kevin M; Patik, Jordan C; Bhella, Paul S
2017-11-01
The goal of this study was to investigate the impact of energy drinks on haemodynamic and cardiac physiology. Comparisons were made to coffee as well as water consumption. In Protocol #1 the caffeine content was normalized to body weight to represent a controlled environment. Heart rate, blood pressure and cardiac QTc interval were assessed in 15 participants, on 4 days, prior to and for 6·5 h postconsumption of (i) energy drink (2 mg caffeine per kg body weight; low dose), (ii) energy drink (3 mg caffeine per kg body weight; medium dose), (iii) coffee (2 mg caffeine per kg body weight) and (iv) 250 ml water. In Protocol #2, the beverages were consumed in volumes that they are purchased to represent real-life conditions. The aforementioned measurements were repeated in 15 participants following (i) 1 16 oz can of energy drink (16 oz Monster), (ii) 1 24 oz can of energy drink (24 oz Monster), (iii) 1 packet of Keurig K-Cup Starbucks coffee (coffee) and (iv) 250 ml water. The order of the beverages was performed in a randomized double-blinded fashion. For both protocols, QTc interval, heart rate and systolic blood pressure were unchanged in any condition (P>0·05). Diastolic blood pressure and mean blood pressure were slightly elevated in Protocol #1 (P<0·05, main effect of time) with no difference between beverages (P<0·05, interaction of beverage × time); however, they were unaffected in Protocol #2 (P>0·05). These findings suggest that acute consumption of these commonly consumed beverages has no negative effect on cardiac QTc interval. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Jackson, Colette E; Castagno, Davide; Maggioni, Aldo P; Køber, Lars; Squire, Iain B; Swedberg, Karl; Andersson, Bert; Richards, A Mark; Bayes-Genis, Antoni; Tribouilloy, Christophe; Dobson, Joanna; Ariti, Cono A; Poppe, Katrina K; Earle, Nikki; Whalley, Gillian; Pocock, Stuart J; Doughty, Robert N; McMurray, John J V
2015-05-07
Low pulse pressure is a marker of adverse outcome in patients with heart failure (HF) and reduced ejection fraction (HF-REF) but the prognostic value of pulse pressure in patients with HF and preserved ejection fraction (HF-PEF) is unknown. We examined the prognostic value of pulse pressure in patients with HF-PEF [ejection fraction (EF) ≥ 50%] and HF-REF. Data from 22 HF studies were examined. Preserved left ventricular ejection fraction (LVEF) was defined as LVEF ≥ 50%. All-cause mortality at 3 years was evaluated in 27 046 patients: 22 038 with HF-REF (4980 deaths) and 5008 with HF-PEF (828 deaths). Pulse pressure was analysed in quintiles in a multivariable model adjusted for the previously reported Meta-Analysis Global Group in Chronic Heart Failure prognostic variables. Heart failure and reduced ejection fraction patients in the lowest pulse pressure quintile had the highest crude and adjusted mortality risk (adjusted hazard ratio 1.68, 95% confidence interval 1.53-1.84) compared with all other pulse pressure groups. For patients with HF-PEF, higher pulse pressure was associated with the highest crude mortality, a gradient that was eliminated after adjustment for other prognostic variables. Lower pulse pressure (especially <53 mmHg) was an independent predictor of mortality in patients with HF-REF, particularly in those with an LVEF < 30% and systolic blood pressure <140 mmHg. Overall, this relationship between pulse pressure and outcome was not consistently observed among patients with HF-PEF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Xavier, Vivian Bertoni; Roxo, Renata Spósito; Miorin, Luiz Antônio; Dos Santos Alves, Vera Lúcia; Dos Santos Sens, Yvoty Alves
2015-06-01
Chronic kidney disease (CKD) patients on long-term dialysis present changes in pulmonary function and respiratory muscle strength, negatively influencing physical capacity. To analyze the impact of a continuous positive airway pressure (CPAP) protocol on the respiratory capacity of CKD patients under hemodialysis. A randomized clinical trial was conducted involving 40 CKD patients 19-83 years old divided into two groups: control (n = 20) and CPAP (n = 20). Subjects were assessed on the respiratory muscle function test, maximal respiratory pressures, peak flow and 6-min walk test, at baseline and again at the 2-month follow-up. CPAP group patients were submitted to CPAP protocol (PEEP: 5 cm H2O, flow: 15 L/min, FiO2: 33 %) three times per week during hemodialysis sessions. The CPAP group showed higher forced vital capacity, forced expiratory volume in one second, peak expiratory flow, maximal inspiratory pressure, peak flow, as well as lower systolic blood pressure, heart rate, respiratory rate and Borg scale, in addition to a longer distance travelled on the 6-min walk test, compared with the control group. The introduction of a CPAP protocol during hemodialysis sessions had a positive impact on pulmonary function and physical capacity in CKD patients.
Cost-effectiveness of wound management in France: pressure ulcers and venous leg ulcers.
Meaume, S; Gemmen, E
2002-06-01
This study set out to define realistic protocols of care for the treatment of chronic venous leg ulcers and pressure ulcers in France and, by developing cost-effectiveness models, to compare the different protocols of care for the two ulcer groups, enabling a calculation of direct medical costs per ulcer healed in a typical French health insurance plan. Clinical outcomes and some treatment patterns were obtained from published literature. Validations of different treatment patterns were developed using an expert consensus panel similar to the Delphi approach. Costs were calculated based on national averages and estimates from the UK and Germany. The models were used to measure costs per healed ulcer over a 12-week period. For both the pressure ulcer and venous leg ulcer models, three protocols of care were identified. For pressure ulcers and venous leg ulcers, the hydrocolloid DuoDERM (ConvaTec, also known as Granuflex in the UK and Varihesive in Germany) was most cost-effective in France. The combination of published data and expert consensus opinion is a valid technique, and in this case suggests that treating pressure ulcers and venous leg ulcers with hydrocolloid dressings is more cost-effective than treating them with saline gauze, in spite of the lower unit cost of the latter.
Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality.
Banegas, José R; Ruilope, Luis M; de la Sierra, Alejandro; Vinyoles, Ernest; Gorostidi, Manuel; de la Cruz, Juan J; Ruiz-Hurtado, Gema; Segura, Julián; Rodríguez-Artalejo, Fernando; Williams, Bryan
2018-04-19
Evidence for the influence of ambulatory blood pressure on prognosis derives mainly from population-based studies and a few relatively small clinical investigations. This study examined the associations of blood pressure measured in the clinic (clinic blood pressure) and 24-hour ambulatory blood pressure with all-cause and cardiovascular mortality in a large cohort of patients in primary care. We analyzed data from a registry-based, multicenter, national cohort that included 63,910 adults recruited from 2004 through 2014 in Spain. Clinic and 24-hour ambulatory blood-pressure data were examined in the following categories: sustained hypertension (elevated clinic and elevated 24-hour ambulatory blood pressure), "white-coat" hypertension (elevated clinic and normal 24-hour ambulatory blood pressure), masked hypertension (normal clinic and elevated 24-hour ambulatory blood pressure), and normotension (normal clinic and normal 24-hour ambulatory blood pressure). Analyses were conducted with Cox regression models, adjusted for clinic and 24-hour ambulatory blood pressures and for confounders. During a median follow-up of 4.7 years, 3808 patients died from any cause, and 1295 of these patients died from cardiovascular causes. In a model that included both 24-hour and clinic measurements, 24-hour systolic pressure was more strongly associated with all-cause mortality (hazard ratio, 1.58 per 1-SD increase in pressure; 95% confidence interval [CI], 1.56 to 1.60, after adjustment for clinic blood pressure) than the clinic systolic pressure (hazard ratio, 1.02; 95% CI, 1.00 to 1.04, after adjustment for 24-hour blood pressure). Corresponding hazard ratios per 1-SD increase in pressure were 1.55 (95% CI, 1.53 to 1.57, after adjustment for clinic and daytime blood pressures) for nighttime ambulatory systolic pressure and 1.54 (95% CI, 1.52 to 1.56, after adjustment for clinic and nighttime blood pressures) for daytime ambulatory systolic pressure. These relationships were consistent across subgroups of age, sex, and status with respect to obesity, diabetes, cardiovascular disease, and antihypertensive treatment. Masked hypertension was more strongly associated with all-cause mortality (hazard ratio, 2.83; 95% CI, 2.12 to 3.79) than sustained hypertension (hazard ratio, 1.80; 95% CI, 1.41 to 2.31) or white-coat hypertension (hazard ratio, 1.79; 95% CI, 1.38 to 2.32). Results for cardiovascular mortality were similar to those for all-cause mortality. Ambulatory blood-pressure measurements were a stronger predictor of all-cause and cardiovascular mortality than clinic blood-pressure measurements. White-coat hypertension was not benign, and masked hypertension was associated with a greater risk of death than sustained hypertension. (Funded by the Spanish Society of Hypertension and others.).
Altunkan, Sekip; Ilman, Nevzat; Altunkan, Erkan
2007-04-01
A variety of automatic blood measurement devices with diverse features have been introduced to the medical markets recently. Among these devices, models that measure at the wrist have become increasingly popular in self measurements. The objective of this study was to evaluate the accuracy of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure devices against the mercury sphygmomanometer in adults according to the International Protocol criteria. Fifty-four patients over 30 years of age were studied and classified based on the International Protocol range. Blood pressure measurements at the wrist with the Samsung SBM-100A and Microlife BP 3BU1-5 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 participants with randomly distributed arm circumferences were selected for both of the validation studies. During each validation study, 99 measurements were obtained for comparison from 33 participants. The first phase was performed on 15 participants and if the device passed this phase, 18 more participants were selected. Mean discrepancies and standard deviations of the device-sphygmomanometer were 0.9+/-9.2 and -2.7+/-9.3 mmHg for systolic blood pressure and -1.4+/-8.0 mmHg and 1.4+/-5.7 for diastolic blood pressure in the Samsung and Microlife study groups, respectively. The Samsung SBM-100A passed Phase 1 in 15 participants. Despite the fact that Microlife BP 3BU1-5 passed Phase 1 for diastolic pressure, it failed according to the systolic pressure criteria. Eighteen patients were added and Phase 2 was continued, in which Samsung SBM-100A failed to meet the criteria of Phases 2.1 and 2.2 for adults in systolic and diastolic blood pressure. It was found that the Microlife BP 3BU1-5 does not meet the criteria of either of Phases 2.1 and 2.2 for systolic blood pressure and Phase 2.2 for diastolic blood pressure. In this study, Samsung SBM-100A and Microlife blood pressure 3BU1-5 wrist blood pressure monitoring devices were found to be incompetent to meet the criteria of the International Protocol and it has not been possible to suggest any one of them for clinical use in adults.
Gender- and hydration- associated differences in the physiological response to spinning.
Ramos-Jiménez, Arnulfo; Hernández-Torres, Rosa Patricia; Wall-Medrano, Abraham; Torres-Durán, Patricia Victoria; Juárez-Oropeza, Marco Antonio; Viloria, María; Villalobos-Molina, Rafael
2014-03-01
There is scarce and inconsistent information about gender-related differences in the hydration of sports persons, as well as about the effects of hydration on performance, especially during indoor sports. To determine the physiological differences between genders during in indoor physical exercise, with and without hydration. 21 spinning sportspeople (12 men and 9 women) participated in three controlled, randomly assigned and non-sequential hydration protocols, including no fluid intake and hydration with plain water or a sports drink (volume adjusted to each individual every 15 min), during 90 min of spinning exercise. The response variables included body mass, body temperature, heart rate and blood pressure. During exercise without hydration, men and women lost ~2% of body mass, and showed higher body temperature (~0.2°C), blood pressure (~4 mmHg) and heart rate (~7 beats/min) compared to exercises with hydration. Body temperature and blood pressure were higher for men than for women during exercise without hydration, differences not observed during exercise with hydration. Between 42-99% of variance in body temperature, blood pressure and heart rate could be explained by the physical characteristics of subjects and the work done. During exercise with hydration (either with water or sport drink), the physiological response was similar for both genders. Exercise without hydration produced physical stress, which could be prevented with either of the fluids (plain water was sufficient). Gender differences in the physiological response to spinning (body temperature, mean blood pressure and heart rate) can be explained in part by the distinct physical characteristics of each individual. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
O'Brien, Claire; Bray, Emma P; Bryan, Stirling; Greenfield, Sheila M; Haque, M Sayeed; Hobbs, F D Richard; Jones, Miren I; Jowett, Sue; Kaambwa, Billingsley; Little, Paul; Mant, Jonathan; Penaloza, Cristina; Schwartz, Claire; Shackleford, Helen; Varghese, Jinu; Williams, Bryan; McManus, Richard J
2013-03-23
Self-monitoring of hypertension with self-titration of antihypertensives (self-management) results in lower systolic blood pressure for at least one year. However, few people in high risk groups have been evaluated to date and previous work suggests a smaller effect size in these groups. This trial therefore aims to assess the added value of self-management in high risk groups over and above usual care. The targets and self-management for the control of blood pressure in stroke and at risk groups (TASMIN-SR) trial will be a pragmatic primary care based, unblinded, randomised controlled trial of self-management of blood pressure (BP) compared to usual care. Eligible patients will have a history of stroke, coronary heart disease, diabetes or chronic kidney disease and will be recruited from primary care. Participants will be individually randomised to either usual care or self-management. The primary outcome of the trial will be difference in office SBP between intervention and control groups at 12 months adjusted for baseline SBP and covariates. 540 patients will be sufficient to detect a difference in SBP between self-management and usual care of 5 mmHg with 90% power. Secondary outcomes will include self-efficacy, lifestyle behaviours, health-related quality of life and adverse events. An economic analysis will consider both within trial costs and a model extrapolating the results thereafter. A qualitative analysis will gain insights into patients' views, experiences and decision making processes. The results of the trial will be directly applicable to primary care in the UK. If successful, self-management of blood pressure in people with stroke and other high risk conditions would be applicable to many hundreds of thousands of individuals in the UK and beyond. ISRCTN87171227.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Arrangements), 2.3 (Test Ducts and Plenums), 2.4 (Test Gases), 2.5 (Test Pressures and Burner Adjustments), 2.6 (Static Pressure and Air Flow Adjustments), 2.39 (Thermal Efficiency) (note, this is 2.38 in ANSI Z21.47... test must be conducted only at the normal inlet test pressure, as specified in section 2.5.1 of ANSI...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Arrangements), 2.3 (Test Ducts and Plenums), 2.4 (Test Gases), 2.5 (Test Pressures and Burner Adjustments), 2.6 (Static Pressure and Air Flow Adjustments), 2.39 (Thermal Efficiency) (note, this is 2.38 in ANSI Z21.47... test must be conducted only at the normal inlet test pressure, as specified in section 2.5.1 of ANSI...
Nair, Erika L; Sousa, Rhonda; Wannagot, Shannon
Guidelines established by the AAA currently recommend behavioral testing when fitting frequency modulated (FM) systems to individuals with cochlear implants (CIs). A protocol for completing electroacoustic measures has not yet been validated for personal FM systems or digital modulation (DM) systems coupled to CI sound processors. In response, some professionals have used or altered the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting FM systems to CI sound processors. More recently steps were outlined in a proposed protocol. The purpose of this research is to review and compare the electroacoustic test measures outlined in a 2013 article by Schafer and colleagues in the Journal of the American Academy of Audiology titled "A Proposed Electroacoustic Test Protocol for Personal FM Receivers Coupled to Cochlear Implant Sound Processors" to the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting DM systems to CI users. Electroacoustic measures were conducted on 71 CI sound processors and Phonak Roger DM systems using a proposed protocol and an adapted AAA protocol. Phonak's recommended default receiver gain setting was used for each CI sound processor manufacturer and adjusted if necessary to achieve transparency. Electroacoustic measures were conducted on Cochlear and Advanced Bionics (AB) sound processors. In this study, 28 Cochlear Nucleus 5/CP810 sound processors, 26 Cochlear Nucleus 6/CP910 sound processors, and 17 AB Naida CI Q70 sound processors were coupled in various combinations to Phonak Roger DM dedicated receivers (25 Phonak Roger 14 receivers-Cochlear dedicated receiver-and 9 Phonak Roger 17 receivers-AB dedicated receiver) and 20 Phonak Roger Inspiro transmitters. Employing both the AAA and the Schafer et al protocols, electroacoustic measurements were conducted with the Audioscan Verifit in a clinical setting on 71 CI sound processors and Phonak Roger DM systems to determine transparency and verify FM advantage, comparing speech inputs (65 dB SPL) in an effort to achieve equal outputs. If transparency was not achieved at Phonak's recommended default receiver gain, adjustments were made to the receiver gain. The integrity of the signal was monitored with the appropriate manufacturer's monitor earphones. Using the AAA hearing aid protocol, 50 of the 71 CI sound processors achieved transparency, and 59 of the 71 CI sound processors achieved transparency when using the proposed protocol at Phonak's recommended default receiver gain. After the receiver gain was adjusted, 3 of 21 CI sound processors still did not meet transparency using the AAA protocol, and 2 of 12 CI sound processors still did not meet transparency using the Schafer et al proposed protocol. Both protocols were shown to be effective in taking reliable electroacoustic measurements and demonstrate transparency. Both protocols are felt to be clinically feasible and to address the needs of populations that are unable to reliably report regarding the integrity of their personal DM systems. American Academy of Audiology
Akar, Gülcan Coşkun; Pekkan, Gürel; Çal, Ebru; Eskitaşçıoğlu, Gürcan; Özcan, Mutlu
2014-08-01
Surface-finishing protocols have a mechanical impact on ceramic surfaces that could eventually affect surface topography and light scattering. An optimum protocol is needed to avoid damaging the optical properties of ceramics. The purpose of this study was to determine the effects of different surface-finishing protocols on the surface roughness, color change, and translucency of ceramic and metal ceramic restorations. Standardized disk-shaped specimens (1.5 × 10 mm, n=128) were fabricated from 3 different ceramic core materials (aluminum oxide [Al2O3]-AL, zirconium oxide [ZrO2]-ZR, lithium disilicate [Li2Si2O5]-LIT), veneered (V) with dentin ceramics (n=32 per group), and placed in the following groups: ALV, ZRV, and LITV. The metal ceramic group acted as the control (n=32). Four different surface-finishing methods were tested. Airborne-particle abrasion with 50 μm Al2O3, polishing with adjustment kit, polishing with adjustment kit plus diamond polishing paste, and autoglazing (n=8 subgroup) were applied on the veneering ceramics. The specimens were analyzed with a profilometer for surface roughness, and color change and translucency were measured with a clinical spectrophotometer. Statistical analyses were performed with 1-way ANOVA and the Tukey honest significant difference tests (α=.05). Specimens treated with the airborne particle abrasion method showed significantly higher mean profilometer for surface roughness values in all groups (P<.05). The polishing with adjustment kit and autoglazing methods revealed statistically similar surface roughness values in all groups (P>.05). With the diamond polishing paste method, lower surface roughness values were achieved in the ZRV and metal ceramic groups acted as the control groups. Different surface-finishing methods affected the color change of the ceramic systems, except for ZRV. Surface-finishing protocols significantly affected the translucency values of the ALV, LITV, and metal ceramic groups (P<.05). No single surface-finishing protocol can be recommended to obtain the smoothest surface and the least color change without affecting translucency for the ceramics tested. The airborne-particle abrasion protocol created rougher surfaces and decreased translucency, and color change in zirconia was not affected by the finishing protocols. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Chansangpetch, Sunee; Huang, Guofu; Coh, Paul; Oldenburg, Catherine; Amoozgar, Behzad; He, Mingguang; Lin, Shan C
2018-04-01
To compare optic nerve head, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell complex (GCC) parameters between Caucasian and ethnic Chinese. Normal subjects above 40 years old and self-identified as being Caucasian and Chinese were recruited. They were evaluated with spectral-domain optical coherence tomography (RTVue-100). Parameters related to the optic nerve head, pRNFL, and GCC analysis protocols were acquired. Multivariable linear regression was performed adjusting for potential confounders. Data from 116 Caucasian and 130 Chinese subjects were available for analysis. Mean age of all participants was 66.72 (SD 10.82) years. There were statistically significant differences for disc area (DA), area cup-to-disc, vertical cup-to-disc, and cup volume (P=0.02, 0.004, 0.02, and 0.03, respectively), greater in Chinese. After adjusting for age, sex, axial length (AL), intraocular pressure (IOP), DA, and GCC thickness, Chinese subjects had significantly greater thickness in all pRNFL parameters (mean differences ranged between 4.29 and 9.93 μm; all P<0.001) except the nasal quadrant. GCC outcomes were also adjusted for DA and pRNFL; Caucasians had significantly higher average GCC and inferior GCC (mean difference 2.97 and 3.45 μm, respectively; P<0.01), whereas the Chinese group had significantly higher ganglion cell global loss volume (mean difference 2.47 %, P<0.001). This study suggests there is significantly greater pRNFL thickness in Chinese, which were independent of age, AL, IOP, and DA, and possibly greater GCC in Caucasians after adjustment for age, AL, IOP, DA, and pRNFL thickness.
Geelhoed, J J Miranda; Fraser, Abigail; Tilling, Kate; Benfield, Li; Davey Smith, George; Sattar, Naveed; Nelson, Scott M; Lawlor, Debbie A
2010-09-21
Offspring of women with hypertensive disorders of pregnancy are at increased risk of cardiovascular complications later in life, but the mechanisms underlying these associations are unclear. Our aim was to examine whether adjusting for birth weight and familial adiposity changed the association of hypertensive disorders of pregnancy with offspring blood pressure. Using data from 6343 nine-year-old participants in the Avon Longitudinal Study of Parents and Children, we examined the association between hypertensive disorders of pregnancy (preeclampsia and gestational hypertension) and offspring blood pressure. Both preeclampsia and gestational hypertension were associated with systolic and diastolic blood pressures in the 9-year-old offspring; after adjustment for parental and own adiposity and for other potential confounders, the mean difference in systolic blood pressure was 2.05 mm Hg (95 confidence interval, 0.72 to 3.38) and 2.04 mm Hg (95 confidence interval, 1.42 to 2.67) for preeclampsia and gestational hypertension, respectively, compared with those with no hypertensive disorders of pregnancy. Equivalent results for diastolic blood pressure were 1.00 mm Hg (95 confidence interval, -0.01 to 2.10) and 1.07 mm Hg (95 confidence interval, 0.60 to 1.54). The association of preeclampsia with offspring systolic and diastolic blood pressures attenuated toward the null with further adjustment for birth weight and gestational age, whereas these adjustments did not attenuate the association of gestational hypertension with offspring blood pressure. The associations of hypertensive disorders of pregnancy with higher offspring blood pressure are not explained by familial adiposity. The mechanisms linking preeclampsia and gestational hypertension with offspring blood pressure may differ, with the former mediated at least in part by the effect of preeclampsia on intrauterine growth restriction.
Practice, clinical management, and financial arrangements of practicing generalists.
Keating, Nancy L; Landon, Bruce E; Ayanian, John Z; Borbas, Catherine; Guadagnoli, Edward
2004-05-01
To describe the practice settings, financial arrangements, and management strategies experienced by generalist physicians and identify factors associated with reporting pressure to limit referrals, pressure to see more patients, and career dissatisfaction. Cross-sectional mail survey. Six hundred nineteen generalist physicians (62% response rate) caring for managed care patients in 3 Minnesota health plans during 1999. Twenty-six percent of physicians reported pressure to limit referrals. In adjusted analyses, female physicians and those who were board certified acted as gatekeepers for most of their patients, received incentives based on performance reports and quality profiles, and received direct income from capitation, and were more likely than others to report this pressure (all P <.05). Sixty-two percent reported pressure to see more patients. In adjusted analyses, this pressure was more frequent among physicians in practices owned by health systems, those using physician extenders, and among physicians paid by salary with performance adjustment or those receiving at least some capitation (all P <.05). One-quarter (24%) of physicians were dissatisfied with their career in medicine. In adjusted analyses, physicians reporting pressure to limit referrals (risk ratio, 1.12; 95% confidence interval, 1.01 to 1.19) and those reporting pressure to see more patients (risk ratio, 1.37; 95% confidence interval, 1.08 to 1.66) were more likely to be dissatisfied than other physicians. Pressures to limit referrals and to see more patients are common, particularly among physicians paid based on productivity or capitation, and they are associated with career dissatisfaction. Whether future changes in practice arrangements or compensation strategies can decrease such physician-reported pressures, and ultimately improve physician satisfaction, will be an important area for future study.
Adult Adjustment of Survivors of Institutional Child Abuse in Ireland
ERIC Educational Resources Information Center
Carr, Alan; Dooley, Barbara; Fitzpatrick, Mark; Flanagan, Edel; Flanagan-Howard, Roisin; Tierney, Kevin; White, Megan; Daly, Margaret; Egan, Jonathan
2010-01-01
Objective: To document the adult adjustment of survivors of childhood institutional abuse. Method: Two hundred and forty-seven adult survivors of institutional abuse with a mean age of 60 were interviewed with a protocol that included the Childhood Trauma Questionnaire, modules from the Structured Clinical Interview for Axis I Disorders of DSM IV…
Singhi, Sunit; Kumar, Ramesh; Singhi, Pratibha; Jayashree, Muralidharan; Bansal, Arun
2015-06-01
Intracranial pressure monitoring can help in early identification of raised intracranial pressure and in setting more informed goals for treatment. We describe our 10-year experience of bedside burr holes performed by pediatric intensivists to establish intracranial pressure monitoring in children with CNS infections in a resource-limited setting and the technical difficulties and complications encountered. Descriptive study of prospectively recorded data. PICU of a tertiary care academic institute. Consecutive comatose patients with raised intracranial pressure who underwent intracranial pressure monitoring from 2004 to 2013. An intraparenchymal (1.2 mm) or an intraventricular transducer (3.4 mm) (Codman) was placed by a pediatric intensivist through a micro burr hole using a standard protocol. Technical difficulties during the procedure and complications were recorded. Over 10 years, 265 intracranial pressure catheters were placed in 259 patients, mainly for acute CNS infections (n = 242, 93.4%). Median age of patients was 4.8 years, youngest being 6 weeks; 21 patients (8.1%) were younger than 1 year. Intraparenchymal transducer was used in 252 patients (97.3%). Median (interquartile range) duration of intracranial pressure monitoring was 96 hours (72-144 hr). Complications were seen in 3.5% of patients (n = 9/259); the incidence was 0.28 per 1,000 hours of intracranial pressure monitoring. Procedure-related ventriculitis occurred in three of seven patients (42.8%) with intraventricular catheter, in contrast to none in patients with intraparenchymal transducer. Overall mortality was 32.8% (n = 85). On Cox-regression analysis, "blood component therapy" was an independent predictor of poor outcome defined as death or severe neurodisability (adjusted hazard ratio, 1.58; 95% CI, 1.16-2.16; p = 0.004). In a resource-limited setting, pediatric intensivists can safely and successfully perform burr holes at bedside for establishing intraparenchymal intracranial pressure monitoring in children with acute CNS infections. However, our data do not support placement of ventriculostomy catheters by pediatric intensivists in similar settings.
Macintyre, Lisa; Stewart, Hazel; Rae, Michelle
2016-12-01
Deep vein thrombosis is a major global health issue, responsible for thousands of deaths each year. While thrombi can form under a variety of circumstances, lack of mobility significantly increases risk and therefore non-ambulant patients are frequently fitted with anti-embolism stockings on admission to hospital, to aid blood flow, prevent pooling and thus clotting. Anti-embolism stockings are the most widely used non-invasive medical device on the market and are believed to reduce the risk of deep vein thrombosis by 40%. Despite their widespread use in hospitals world-wide, there is remarkably little research addressing their use or reconditioning and a wide variety of different reconditioning protocols are used in hospitals. The objective of this study was to establish the impact of different wear and reconditioning protocols on the pressure delivering ability of anti-embolism stockings. A laboratory investigation was undertaken to evaluate the pressure delivering ability of 2 major global brands of anti-embolism stockings over 5-8days of simulated wear (extension on static cylinders) and 4 different reconditioning protocols. 1 set of samples was continuously 'worn' for 8days without reconditioning, 1 set of samples was 'worn' for 5days with a day of relaxation between each day of 'wear', 1 set was 'hand washed' and 1 set was machine washed and then allowed to relax between each day of 'wear'. The pressure was measured at the beginning and end of each period of 'wear'. This study was undertaken in a conditioned textile testing laboratory that complies with BS EN ISO 139:2005+A1:2011. The pressure exerted by anti-embolism stockings reduced by between 15 and 24% after 24h of wear, it reduced by between 21 and 32% when worn continuously for 8days. Allowing stockings to rest for a day between days of wear allowed them to recover slightly but this recovery was only temporary. Washing stockings regenerated their pressure delivering potential significantly and machine washing allowed some to recover to exert more pressure than they had when new. Different brands of anti-embolism stockings exert different pressures on the same size of leg, when correctly fitted. The pressure exerted by anti-embolism stockings decreases with use but the correct pressure gradient is maintained if correctly fitted. Washing stockings after 24h of wear is effective in restoring their pressure delivering abilities and in some cases can surpass their 'as new' pressure delivering ability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Protocol for determining bull trout presence
Peterson, James; Dunham, Jason B.; Howell, Philip; Thurow, Russell; Bonar, Scott
2002-01-01
The Western Division of the American Fisheries Society was requested to develop protocols for determining presence/absence and potential habitat suitability for bull trout. The general approach adopted is similar to the process for the marbled murrelet, whereby interim guidelines are initially used, and the protocols are subsequently refined as data are collected. Current data were considered inadequate to precisely identify suitable habitat but could be useful in stratifying sampling units for presence/absence surveys. The presence/absence protocol builds on previous approaches (Hillman and Platts 1993; Bonar et al. 1997), except it uses the variation in observed bull trout densities instead of a minimum threshold density and adjusts for measured differences in sampling efficiency due to gear types and habitat characteristics. The protocol consists of: 1. recommended sample sizes with 80% and 95% detection probabilities for juvenile and resident adult bull trout for day and night snorkeling and electrofishing adjusted for varying habitat characteristics for 50m and 100m sampling units, 2. sampling design considerations, including possible habitat characteristics for stratification, 3. habitat variables to be measured in the sampling units, and 3. guidelines for training sampling crews. Criteria for habitat strata consist of coarse, watershed-scale characteristics (e.g., mean annual air temperature) and fine-scale, reach and habitat-specific features (e.g., water temperature, channel width). The protocols will be revised in the future using data from ongoing presence/absence surveys, additional research on sampling efficiencies, and development of models of habitat/species occurrence.
de Almeida, Antonio Eduardo Monteiro; Stein, Ricardo; Gus, Miguel; Nascimento, João Agnaldo; Belli, Karlyse Claudino; Arévalo, Jorge Rene Garcia; Fuchs, Flávio Dani
2014-01-01
Background The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers. PMID:25352508
Cardiovascular responses to plyometric exercise are affected by workload in athletes
Arazi, Hamid; Mahdavi, Seyed Amir; Nasiri, Seyed Omid Mirfalah
2014-01-01
Introduction With regard to blood pressure responses to plyometric exercise and decreasing blood pressure after exercise (post-exercise hypotension), the influence of different workloads of plyometric exercise on blood pressure is not clear. Aim The purpose of this investigation was to examine the effects of a low, moderate and high workload of plyometric exercise on the post-exercise systolic (SBP) and diastolic blood pressure (DBP), heart rate (HR) and rate-pressure product (RPP) responses in athletes. Material and methods Ten male athletes (age: 22.6 ±0.5 years; height: 178.2 ±3.3 cm; and body mass: 75.2 ±2.8 kg) underwent PE protocols involving 5 × 10 reps (Low Workload – LW), 10 × 10 reps (Moderate Workload – MW), and 15 × 10 reps (High Workload – HW) depth jump exercise from a 50-cm box in 3 non-consecutive days. After each exercise session, SBP, DBP and HR were measured every 10 min for a period of 70 min. Results No significant differences were observed among post-exercise SBP and DBP when the protocols (LW, MW and HW) were compared. The MW and HW protocols showed greater increases in HR compared with LW. Also the HW indicated greater increases than LW in RPP at post-exercise (p < 0.05). Conclusions All protocols increased SBP, HR and RPP responses at the 10th and 20th min of post-exercise. With regard to different workloads of plyometric exercise, HW condition indicated greater increases in HR and RPP and strength and conditioning professionals and athletes must keep in their mind that HW of plyometric exercise induces greater cardiovascular responses. PMID:24799919
Hu, G; Jousilahti, P; Peltonen, M; Bidel, S; Tuomilehto, J
2006-12-01
To examine joint associations of coffee consumption and other factors (including physical activity, obesity and alcohol consumption) with the risk of type 2 diabetes. Prospective follow-up study. In all, 10 188 Finnish men and 11 197 women aged 35-74 years without a history of stroke, coronary heart disease or diabetes at baseline. A self-administered questionnaire data on coffee, tea, alcohol and other food consumption, physical activity, smoking, socio-economic factors and medical history, together with measured height, weight and blood pressure using standardized protocol. During a mean follow-up of 13.4 years, there were 964 incident cases of type 2 diabetes. Multivariate-adjusted (age, study year, systolic blood pressure, education, smoking, physical activity, body mass index (BMI) and fruit, vegetable, sausage, bread, alcohol and tea consumption) hazard ratio of type 2 diabetes in participants who drank 0-2, 3-6 and > or =7 cups of coffee were 1.00, 0.77 and 0.66 (P=0.022 for trend) in men, 1.00, 0.71 and 0.52 (P=0.001 for trend) in women, and 1.00, 0.75 and 0.61 (P<0.001 for trend) in men and women combined (adjusted also for sex), respectively. This inverse association was consistent in subjects with any joint levels of physical activity and BMI, and in alcohol drinkers and non-drinkers. Among obese and inactive people, coffee drinking of seven cups or more daily reduced the risk of type 2 diabetes to half. Coffee drinking was associated with a reduced risk of type 2 diabetes in both men and women, and this association was observed regardless of the levels of physical activity, BMI and alcohol consumption.
2014-01-01
BACKGROUND Elevated blood pressure (BP), a heritable risk factor for many age-related disorders, is commonly investigated in population and genetic studies, but antihypertensive use can confound study results. Routine methods to adjust for antihypertensives may not sufficiently account for newer treatment protocols (i.e., combination or multiple drug therapy) found in contemporary cohorts. METHODS We refined an existing method to impute unmedicated BP in individuals on antihypertensives by incorporating new treatment trends. We assessed BP and antihypertensive use in male twins (n = 1,237) from the Vietnam Era Twin Study of Aging: 36% reported antihypertensive use; 52% of those treated were on multiple drugs. RESULTS Estimated heritability was 0.43 (95% confidence interval (CI) = 0.20–0.50) and 0.44 (95% CI = 0.22–0.61) for measured systolic BP (SBP) and diastolic BP (DBP), respectively. We imputed BP for antihypertensives by 3 approaches: (i) addition of a fixed value of 10/5mm Hg to measured SBP/DBP; (ii) incremented addition of mm Hg to BP based on number of medications; and (iii) a refined approach adding mm Hg based on antihypertensive drug class and ethnicity. The imputations did not significantly affect estimated heritability of BP. However, use of our most refined imputation method and other methods resulted in significantly increased phenotypic correlations between BP and body mass index, a trait known to be correlated with BP. CONCLUSIONS This study highlights the potential usefulness of applying a representative adjustment for medication use, such as by considering drug class, ethnicity, and the combination of drugs when assessing the relationship between BP and risk factors. PMID:24532572
Kaczka, David W.; Herrmann, Jacob; Zonneveld, C. Elroy; Tingay, David G.; Lavizzari, Anna; Noble, Peter B.; Pillow, J. Jane
2015-01-01
Background Despite the theoretical benefits of high-frequency oscillatory ventilation (HFOV) in preterm infants, systematic reviews of randomized clinical trials do not confirm improved outcomes. We hypothesized that oscillating a premature lung with multiple frequencies simultaneously would improve gas exchange compared to traditional single-frequency oscillatory ventilation (SFOV). The goal of this study was to develop a novel method for HFOV, termed ‘multi-frequency oscillatory ventilation’ (MFOV), which relies on a broadband flow waveform more suitable for the heterogeneous mechanics of the immature lung. Methods Thirteen intubated preterm lambs were randomized to either SFOV or MFOV for 1 hour, followed by crossover to the alternative regimen for 1 hour. The SFOV waveform consisted of a pure sinusoidal flow at 5 Hz, while the customized MFOV waveform consisted of a 5 Hz fundamental with additional energy at 10 and 15 Hz. Per standardized protocol, mean pressure at airway opening (P̅ao) and inspired O2 fraction were adjusted as needed, and root mean square of the delivered oscillatory volume waveform (Vrms) was adjusted 15-minute intervals. A ventilatory cost function for SFOV and MFOV was defined as VC=(Vrms2PaCO2)Wt−1, where Wt denotes body weight. Results Averaged over all time points, MFOV resulted in significantly lower VC (246.9±6.0 vs. 363.5±15.9 mL2 mmHg kg−1) and P̅ao (12.8±0.3 vs. 14.1±0.5 cmH2O) compared to SFOV, suggesting more efficient gas exchange and enhanced lung recruitment at lower mean airway pressures. Conclusions Oscillation with simultaneous multiple frequencies may be a more efficient ventilator modality in premature lungs compared to traditional single-frequency HFOV. PMID:26495977
Improving Pressure Ulcer Reconstruction: Our Protocol and the COP (Cone of Pressure) Flap
Edstrom, Lee; Szymanski, Karen; Schmidt, Scott; Bevivino, Jack; Zienowicz, Richard; Stark, Jennifer; Taylor, Helena O.; Podda, Silvio; Liu, Paul
2017-01-01
Background: Surgical treatment of pressure ulcers is challenging for high recurrence rates. Deepithelialized flaps have been used previously with the aim to eliminate shearing forces and the cone of pressure (COP) effect. The goal of this study is to adopt a standardized protocol and evaluate if 2 different flap techniques affect outcomes. Methods: The novel COP flap is illustrated. Twenty patients were prospectively treated with flap coverage over a 36-month period. According to the flap type, patients were assigned to 2 groups: group 1 with 11 patients treated with the COP flap and group 2 with 9 patients treated with conventional flap without anchoring technique. We adopted a standardized protocol of debridement, tissue cultures, and negative-pressure wound therapy. Rotation fasciocutaneous flaps were used for both groups and mean follow-up was 19 months. The COP flap is a large deepithelialized rotation flap inset with transcutaneous nonabsorbable bolster sutures. The 2 groups were comparable for demographics and ulcer location and size (P < 0.05). Five patients showed positive cultures and were treated with antibiotics and negative-pressure therapy before surgery. Results: Recurrence rates were 12% in the COP flap group and 60% in the conventional flap coverage group (P < 0.001). Results were compared at 16-month follow-up. Conclusions: The COP flap significantly reduces recurrences and eliminates shearing forces, suture ripping, and tension on superficial soft-tissue layers. The technique can be applied to both ischial and sacral pressure sores. The flap provides padding over bony prominence without jeopardizing flap vascularity. PMID:28458961
Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon
2013-05-01
The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.
NASA Technical Reports Server (NTRS)
Bard, Steven (Inventor); Wu, Jiunn-Jeng (Inventor); Trimble, Curtis A. (Inventor)
1992-01-01
A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.
NASA Astrophysics Data System (ADS)
Bard, Steven; Wu, Jiunn-Jeng; Trimble, Curtis A.
1992-06-01
A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.
Prevention of Tracheostomy-Related Hospital-Acquired Pressure Ulcers.
O'Toole, Thomas R; Jacobs, Natalie; Hondorp, Brian; Crawford, Laura; Boudreau, Lisa R; Jeffe, Jill; Stein, Brian; LoSavio, Phillip
2017-04-01
Objective To determine if standardization of perioperative tracheostomy care procedures decreased the incidence of hospital-acquired tracheostomy-related pressure ulcers. Methods All patients at least 18 years old who underwent placement of a tracheostomy tube in the operating room from July 1, 2014, through June 30, 2015, were cared for postoperatively through an institutionally adopted quality improvement protocol. This included 4 elements: (1) placement of a hydrocolloid dressing underneath the tracheostomy flange in the postoperative period, (2) removal of plate sutures within 7 days of the tracheostomy procedure, (3) placement of a polyurethane foam dressing after suture removal, and (4) neutral positioning of the head. One year after the bundle was initiated, a retrospective analysis was performed to compare the percentage of tracheostomy patients who developed pressure ulcers versus the preintervention period. Results The incidence of tracheostomy-related pressure ulcers decreased from 20 of 183 tracheostomies (10.93%) prior to use of the standardized protocol to 2 of 155 tracheostomies (1.29%). Chi-square analysis showed a significant difference between the groups, with a P value of .0003. Discussion Adoption of this care bundle at our institution resulted in a significant reduction in the incidence of hospital-acquired tracheostomy-related pressure ulcers. The impact of any single intervention within our protocol was not assessed and could be an area of further investigation. Implications for Practice Adoption of a standardized posttracheostomy care bundle at the institution level may result in the improved care of patients with tracheostomies and specifically may reduce the incidence of pressure ulcers.
Muller, Matthew D.; Gao, Zhaohui; Drew, Rachel C.; Herr, Michael D.; Leuenberger, Urs A.
2011-01-01
The effects of cold air inhalation and isometric exercise on coronary blood flow are currently unknown, despite the fact that both cold air and acute exertion trigger angina in clinical populations. In this study, we used transthoracic Doppler echocardiography to measure coronary blood flow velocity (CBV; left anterior descending coronary artery) and myocardial function during cold air inhalation and handgrip exercise. Ten young healthy subjects underwent the following protocols: 5 min of inhaling cold air (cold air protocol), 5 min of inhaling thermoneutral air (sham protocol), 2 min of isometric handgrip at 30% of maximal voluntary contraction (grip protocol), and 5 min of isometric handgrip at 30% maximal voluntary contraction while breathing cold air (cold + grip protocol). Heart rate, blood pressure, inspired air temperature, CBV, myocardial function (tissue Doppler imaging), O2 saturation, and pulmonary function were measured. The rate-pressure product (RPP) was used as an index of myocardial O2 demand, whereas CBV was used as an index of myocardial O2 supply. Compared with the sham protocol, the cold air protocol caused a significantly higher RPP, but there was a significant reduction in CBV. The cold + grip protocol caused a significantly greater increase in RPP compared with the grip protocol (P = 0.045), but the increase in CBV was significantly less (P = 0.039). However, myocardial function was not impaired during the cold + grip protocol relative to the grip protocol alone. Collectively, these data indicate that there is a supply-demand mismatch in the coronary vascular bed when cold ambient air is breathed during acute exertion but myocardial function is preserved, suggesting an adequate redistribution of blood flow. PMID:21940852
White, Scott C; Hostler, David
2017-08-01
Fire suppression wearing thermal protective clothing (TPC) and self-contained breathing apparatus (SCBA) challenges a firefighter's balance and may explain firefighter falls. Postural control based on force plate centre of pressure (COP) was compared for healthy subjects wearing TPC and SCBA before and after 20 min of heavy physical exertion in hot conditions. Baseline measures with and without TPC and SCBA (two different SCBA cylinder masses) were compared before and after exertion that included elements of fire suppression activities in an environmental chamber. COP excursion and variability increased with exertion for TPC and SCBA conditions compared to non-stressed conditions. The two different cylinder masses had no significant effect. Wearing TPC and SCBA when physically stressed in a hot environment increases postural sway and exacerbates postural control. Subjects compensated for the extra mass and adjusted to control postural sway with the addition of TPC and SCBA, but the stress protocol amplified these adjustments. Practitioner Summary: Firefighters wear thermal protective clothing (TPC) and self-contained breathing apparatus (SCBA) when heat-stressed and fatigued. Wearing TPC and SCBA was found to negatively impact balance when stressed, but not for non-stressed or two different sized SCBA tanks. Simulating fire-ground conditions wearing TPC and SCBA should be considered for improving balance.
Newth, Christopher J L; Sward, Katherine A; Khemani, Robinder G; Page, Kent; Meert, Kathleen L; Carcillo, Joseph A; Shanley, Thomas P; Moler, Frank W; Pollack, Murray M; Dalton, Heidi J; Wessel, David L; Berger, John T; Berg, Robert A; Harrison, Rick E; Holubkov, Richard; Doctor, Allan; Dean, J Michael; Jenkins, Tammara L; Nicholson, Carol E
2017-11-01
Although pediatric intensivists philosophically embrace lung protective ventilation for acute lung injury and acute respiratory distress syndrome, we hypothesized that ventilator management varies. We assessed ventilator management by evaluating changes to ventilator settings in response to blood gases, pulse oximetry, or end-tidal CO2. We also assessed the potential impact that a pediatric mechanical ventilation protocol adapted from National Heart Lung and Blood Institute acute respiratory distress syndrome network protocols could have on reducing variability by comparing actual changes in ventilator settings to those recommended by the protocol. Prospective observational study. Eight tertiary care U.S. PICUs, October 2011 to April 2012. One hundred twenty patients (age range 17 d to 18 yr) with acute lung injury/acute respiratory distress syndrome. Two thousand hundred arterial and capillary blood gases, 3,964 oxygen saturation by pulse oximetry, and 2,757 end-tidal CO2 values were associated with 3,983 ventilator settings. Ventilation mode at study onset was pressure control 60%, volume control 19%, pressure-regulated volume control 18%, and high-frequency oscillatory ventilation 3%. Clinicians changed FIO2 by ±5 or ±10% increments every 8 hours. Positive end-expiratory pressure was limited at ~10 cm H2O as oxygenation worsened, lower than would have been recommended by the protocol. In the first 72 hours of mechanical ventilation, maximum tidal volume/kg using predicted versus actual body weight was 10.3 (8.5-12.9) (median [interquartile range]) versus 9.2 mL/kg (7.6-12.0) (p < 0.001). Intensivists made changes similar to protocol recommendations 29% of the time, opposite to the protocol's recommendation 12% of the time and no changes 56% of the time. Ventilator management varies substantially in children with acute respiratory distress syndrome. Opportunities exist to minimize variability and potentially injurious ventilator settings by using a pediatric mechanical ventilation protocol offering adequately explicit instructions for given clinical situations. An accepted protocol could also reduce confounding by mechanical ventilation management in a clinical trial.
Delwel, Ernst J; de Jong, Dirk A; Dammers, Ruben; Kurt, Erkan; van den Brink, Wimar; Dirven, Clemens M F
2013-07-01
In treating idiopathic normal pressure hydrocephalus (INPH) with a shunt there is always a risk of underdrainage or overdrainage. The hypothesis is tested whether patients treated using an adjustable valve preset at the highest opening pressure leads to comparable good clinical results with less subdural effusions than in a control group with an opening pressure preset at a low pressure level. A multicentre prospective randomised trial was performed on a total of 58 patients suspected of INPH. Thirty patients were assigned to (control) group 1 and received a Strata shunt (Medtronic, Goleta, USA) with the valve preset at a performance level (PL) of 1.0, while 28 patients were assigned to group 2 and received a Strata shunt with the valve preset at PL 2.5. In this group the PL was allowed to be lowered until improvement or radiological signs of overdrainage were met. Significantly more subdural effusions were observed in the improved patients of group 1. There was no statistically significant difference in improvement between both groups overall. On the basis of this multicentre prospective randomised trial it is to be recommended to treat patients with INPH with a shunt with an adjustable valve, preset at the highest opening pressure and lowered until clinical improvement or radiological signs of overdrainage occur although slower improvement and more shunt adjustments might be the consequence.
Yuan, Qiang; Wu, Xing; Yu, Jian; Sun, Yirui; Li, Zhiqi; Du, Zhuoying; Mao, Ying; Zhou, Liangfu; Hu, Jin
2015-07-01
To evaluate the efficacy of traumatic brain injury management guided by intracranial pressure monitoring and to explore the specific subgroups for which intracranial pressure monitoring might be significantly associated with improved outcomes based on a classification of the various traumatic brain injury pathophysiologies using the clinical features and CT scans. Retrospective observational multicenter study. Twenty-two hospitals (16 level I trauma centers and six level II trauma centers) in nine provinces in China. Moderate or severe traumatic brain injury patients who were more than 14 years old. Intracranial pressure monitoring. All data were collected by physicians from medical records. The 6-month mortality and favorable outcome were assessed with the Glasgow Outcome Scale Extended score. An intracranial pressure monitor was inserted into 838 patients (58.1%). The mean duration of intracranial pressure monitoring was 4.44 ± 3.65 days. The significant predictors of intracranial pressure monitoring included the mechanism of injury, a Glasgow Coma Scale score of 9-12 at admission that dropped to a score of 3-8 within 24 hours after injury, a Marshall CT classification of III-IV, the presence of a major extracranial injury, subdural hematoma, intraparenchymal lesions, trauma center level, and intracranial pressure monitoring utilization of hospital. The intracranial pressure monitoring and no intracranial pressure monitoring groups did not significantly differ in terms of complications. For the total sample, the placement of intracranial pressure monitoring was not associated with either 6-month mortality (16.9% vs 20.5%; p = 0.086) or 6-month unfavorable outcome (49.4% vs 45.8%; p = 0.175). For patients with a Glasgow Coma Scale score of 3-8 at admission, intracranial pressure monitoring was also not significantly associated with 6-month mortality (20.9% vs 26.0%; p = 0.053) or an unfavorable outcome (56.9% vs 55.5%; p = 0.646). Multivariate logistic regression analyses showed that intracranial pressure monitoring resulted in a significantly lower 6-month mortality for patients who had a Glasgow Coma Scale score of 3-5 at admission (adjusted odds ratio, 0.57; 95% CI, 0.36-0.90; adjusted p = 0.016), those who had a Glasgow Coma Scale score of 9-12 at admission that dropped to 3-8 within 24 hours after injury (adjusted odds ratio, 0.28; 95% CI, 0.08-0.96; adjusted p = 0.043), and those who had a probability of death at 6 months greater than 0.6 (adjusted odds ratio, 0.55; 95% CI, 0.32-0.94; adjusted p = 0.029). There were multiple differences between the intracranial pressure monitoring and no intracranial pressure monitoring groups regarding patient characteristics, injury severity, characteristics of CT scan, and hospital type. Intracranial pressure monitoring in conjunction with intracranial pressure-targeted therapies is significantly associated with lower mortality in some special traumatic brain injury subgroups. The prospective randomized controlled trials specifically investigating these subgroups will be required to further characterize the effects of intracranial pressure monitoring on behavioral outcomes in patients with traumatic brain injury.
2010-01-01
Summary: Noninvasive positive pressure ventilation (NPPV) devices are used during sleep to treat patients with diurnal chronic alveolar hypoventilation (CAH). Bilevel positive airway pressure (BPAP) using a mask interface is the most commonly used method to provide ventilatory support in these patients. BPAP devices deliver separately adjustable inspiratory positive airway pressure (IPAP) and expiratory positive airway pressure (EPAP). The IPAP and EPAP levels are adjusted to maintain upper airway patency, and the pressure support (PS = IPAP-EPAP) augments ventilation. NPPV devices can be used in the spontaneous mode (the patient cycles the device from EPAP to IPAP), the spontaneous timed (ST) mode (a backup rate is available to deliver IPAP for the set inspiratory time if the patient does not trigger an IPAP/EPAP cycle within a set time window), and the timed (T) mode (inspiratory time and respiratory rate are fixed). During NPPV titration with polysomnography (PSG), the pressure settings, backup rate, and inspiratory time (if applicable) are adjusted to maintain upper airway patency and support ventilation. However, there are no widely available guidelines for the titration of NPPV in the sleep center. A NPPV Titration Task Force of the American Academy of Sleep Medicine reviewed the available literature and developed recommendations based on consensus and published evidence when available. The major recommendations derived by this consensus process are as follows: General Recommendations:The indications, goals of treatment, and side effects of NPPV treatment should be discussed in detail with the patient prior to the NPPV titration study.Careful mask fitting and a period of acclimatization to low pressure prior to the titration should be included as part of the NPPV protocol.NPPV titration with PSG is the recommended method to determine an effective level of nocturnal ventilatory support in patients with CAH. In circumstances in which NPPV treatment is initiated and adjusted empirically in the outpatient setting based on clinical judgment, a PSG should be utilized if possible to confirm that the final NPPV settings are effective or to make adjustments as necessary.NPPV treatment goals should be individualized but typically include prevention of worsening of hypoventilation during sleep, improvement in sleep quality, relief of nocturnal dyspnea, and providing respiratory muscle rest.When OSA coexists with CAH, pressure settings for treatment of OSA may be determined during attended NPPV titration PSG following AASM Clinical Guidelines for the Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea.Attended NPPV titration with PSG is the recommended method to identify optimal treatment pressure settings for patients with the obesity hypoventilation syndrome (OHS), CAH due to restrictive chest wall disease (RTCD), and acquired or central CAH syndromes in whom NPPV treatment is indicated.Attended NPPV titration with PSG allows definitive identification of an adequate level of ventilatory support for patients with neuromuscular disease (NMD) in whom NPPV treatment is planned. Recommendations for NPPV Titration Equipment:The NPPV device used for titration should have the capability of operating in the spontaneous, spontaneous timed, and timed mode.The airflow, tidal volume, leak, and delivered pressure signals from the NPPV device should be monitored and recorded if possible. The airflow signal should be used to detect apnea and hypopnea, while the tidal volume signal and respiratory rate are used to assess ventilation.Transcutaneous or end-tidal PCO2 may be used to adjust NPPV settings if adequately calibrated and ideally validated with arterial blood gas testing.An adequate assortment of masks (nasal, oral, and oronasal) in both adult and pediatric sizes (if children are being titrated), a source of supplemental oxygen, and heated humidification should be available. Recommendations for Limits of IPAP, EPAP, and PS Settings:The recommended minimum starting IPAP and EPAP should be 8 cm H2O and 4 cm H2O, respectively.The recommended maximum IPAP should be 30 cm H2O for patients ≥ 12 years and 20 cm H2O for patients < 12 years.The recommended minimum and maximum levels of PS are 4 cm H2O and 20 cm H2O, respectively.The minimum and maximum incremental changes in PS should be 1 and 2 cm H2O, respectively. Recommendations for Adjustment of IPAP, EPAP, and PS:IPAP and/or EPAP should be increased as described in AASM Clinical Guidelines for the Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea until the following obstructive respiratory events are eliminated (no specific order): apneas, hypopneas, respiratory effort-related arousals, and snoring.The pressure support (PS) should be increased every 5 minutes if the tidal volume is low (< 6 to 8 mL/kg)The PS should be increased if the arterial PCO2 remains 10 mm Hg or more above the PCO2 goal at the current settings for 10 minutes or more. An acceptable goal for PCO2 is a value less than or equal to the awake PCO2.The PS may be increased if respiratory muscle rest has not been achieved by NPPV treatment at the current settings for 10 minutes of more.The PS may be increased if the SpO2 remains below 90% for 5 minutes or more and tidal volume is low (< 6 to 8 mL/kg). Recommendations for Use and Adjustment of the Backup Rate/Respiratory Rate:A backup rate (i.e., ST mode) should be used in all patients with central hypoventilation, those with a significant number of central apneas or an inappropriately low respiratory rate, and those who unreliably trigger IPAP/EPAP cycles due to muscle weakness.The ST mode may be used if adequate ventilation or adequate respiratory muscle rest is not achieved with the maximum (or maximum tolerated) PS in the spontaneous mode.The starting backup rate should be equal to or slightly less than the spontaneous sleeping respiratory rate (minimum of 10 bpm).The backup rate should be increased in 1 to 2 bpm increments every 10 minutes if the desired goal of the backup rate has not been attained.The IPAP time (inspiratory time) should be set based on the respiratory rate to provide an inspiratory time (IPAP time) between 30% and 40% of the cycle time (60/respiratory rate in breaths per minute).If the spontaneous timed mode is not successful at meeting titration goals then the timed mode can be tried. Recommendations Concerning Supplemental Oxygen:Supplemental oxygen may be added in patients with an awake SpO2 < 88% or when the PS and respiratory rate have been optimized but the SpO2 remains < 90% for 5 minutes or more.The minimum starting supplemental oxygen rate should be 1 L/minute and increased in increments of 1 L/minute about every 5 minutes until an adequate SpO2 is attained (> 90%). Recommendations to Improve Patient Comfort and Patient-NPPV Device Synchrony:If the patient awakens and complains that the IPAP and/or EPAP is too high, pressure should be lowered to a level comfortable enough to allow return to sleep.NPPV device parameters (when available) such as pressure relief, rise time, maximum and minimum IPAP durations should be adjusted for patient comfort and to optimize synchrony between the patient and the NPPV device.During the NPPV titration mask refit, adjustment, or change in mask type should be performed whenever any significant unintentional leak is observed or the patient complains of mask discomfort. If mouth leak is present and is causing significant symptoms (e.g., arousals) use of an oronasal mask or chin strap may be tried. Heated humidification should be added if the patient complains of dryness or significant nasal congestion. Recommendations for Follow-Up:Close follow-up after initiation of NPPV by appropriately trained health care providers is indicated to establish effective utilization patterns, remediate side effects, and assess measures of ventilation and oxygenation to determine if adjustment to NPPV is indicated. Citation: Berry RB; Chediak A; Brown LK; Finder J; Gozal D; Iber C; Kushida CA; Morgenthaler T; Rowley JA; Davidson-Ward SL. Best clinical practices for the sleep center adjustment of noninvasive positive pressure ventilation (NPPV) in stable chronic alveolar hypoventilation syndromes. J Clin Sleep Med 2010;6(5):497-509. PMID:20957853
Wu, Ning; Zhang, Xuezhong; Wang, Wen; Zhang, Hongye
2016-04-01
This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Andon KD595 for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were sequentially measured in 33 participants using the standard mercury sphygmomanometer and the Andon KD595 device. Ninety-nine pairs of comparisons were obtained from 33 participants for analysis. The KD595 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and the observers within a range of 5, 10, and 15 mmHg was 72/99, 93/99, and 96/99, respectively, for SBP and 72/99, 96/99, and 99/99, respectively, for DBP. The device also achieved the targets in part 2 of the validation study. A total of 28 and 25 participants had at least two of the three device-observer differences within 5 mmHg (required≥24) for SBP and DBP, respectively. The number of participants without device-observer difference within 5 mmHg was two for SBP and two for DBP (required≤3). The Andon upper arm blood pressure monitor KD595 has passed the International Protocol requirements and it can be recommended for clinical use and self-measurement in adults.
Herts, Brian R; Baker, Mark E; Obuchowski, Nancy; Primak, Andrew; Schneider, Erika; Rhana, Harpreet; Dong, Frank
2013-06-01
The purpose of this article is to determine the decrease in volume CT dose index (CTDI(vol)) and dose-length product (DLP) achieved by switching from fixed quality reference tube current protocols with automatic tube current modulation to protocols adjusting the quality reference tube current, slice collimation, and peak kilovoltage according to patient weight. All adult patients who underwent CT examinations of the abdomen or abdomen and pelvis during 2010 using weight-based protocols who also underwent a CT examination in 2008 or 2009 using fixed quality reference tube current protocols were identified from the radiology information system. Protocol pages were electronically retrieved, and the CT model, examination date, scan protocol, CTDI(vol), and DLP were extracted from the DICOM header or by optical character recognition. There were 15,779 scans with dose records for 2700 patients. Changes in CTDI(vol) and DLP were compared only between examinations of the same patient and same CT system model for examinations performed in 2008 or 2009 and those performed in 2010. The final analysis consisted of 1117 comparisons in 1057 patients, and 1209 comparisons in 988 patients for CTDI(vol) and DLP, respectively. The change to a weight-based protocol resulted in a statistically significant reduction in CTDI(vol) and DLP on three MDCT system models (p < 0.001). The largest average CTDI(vol) decrease was 13.9%, and the largest average DLP decrease was 16.1% on a 64-MDCT system. Both the CTDI(vol) and DLP decreased the most for patients who weighed less than 250 lb (112.5 kg). Adjusting the CT protocol by selecting parameters according to patient weight is a viable method for reducing CT radiation dose. The largest reductions occurred in the patients weighing less than 250 lb.
Private database queries based on counterfactual quantum key distribution
NASA Astrophysics Data System (ADS)
Zhang, Jia-Li; Guo, Fen-Zhuo; Gao, Fei; Liu, Bin; Wen, Qiao-Yan
2013-08-01
Based on the fundamental concept of quantum counterfactuality, we propose a protocol to achieve quantum private database queries, which is a theoretical study of how counterfactuality can be employed beyond counterfactual quantum key distribution (QKD). By adding crucial detecting apparatus to the device of QKD, the privacy of both the distrustful user and the database owner can be guaranteed. Furthermore, the proposed private-database-query protocol makes full use of the low efficiency in the counterfactual QKD, and by adjusting the relevant parameters, the protocol obtains excellent flexibility and extensibility.
Stergiou, George S; Asmar, Roland; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Shennan, Andrew; Wang, Jiguang; O'Brien, Eoin
2018-03-01
The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols. A review of published (PubMed) validation studies from 2002 to 2017 was performed. One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function). The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.
Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi
2017-04-01
To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.
A longitudinal study of altered taste and smell perception and change in blood pressure.
Liu, Y-H; Huang, Z; Vaidya, A; Li, J; Curhan, G C; Wu, S; Gao, X
2018-05-29
Previous studies suggest that olfactory receptors, which mediate smell chemosensation, are located in the kidney and involved in blood pressure regulation. Mammalian epithelial sodium channels located in taste receptor cells are also found to participate in blood pressure regulation. However, there is currently no human study that has examined the association between taste and smell function and blood pressure. We thus conducted a longitudinal study to examine whether participants with altered taste and smell perception had larger increases in blood pressure compared with those without altered perception in a community-based cohort. The study included 5190 Chinese adults (4058 men and 1132 women) who were normotensive at baseline. Taste and smell perception were assessed via questionnaire in 2012 (baseline). Blood pressure was measured in 2012 and 2014 to determine relative change in blood pressure. Mean differences of 2-year blood pressure change and 95% confidence intervals (CIs) across four categories of taste and smell perception were calculated after adjusting for known risk factors for hypertension. After adjusting for potential confounders, individuals with altered taste and smell perception had larger increases in systolic blood pressure (adjusted mean difference = 5.1 mmHg, 95% CI: 0.1-10.0, p-value: 0.04) and mean arterial pressure (adjusted mean difference = 3.8 mmHg, 95% CI: 0.4-7.1, p-value: 0.03) after two years of follow-up compared with those having neither altered taste nor altered smell perception. No significant association was observed in individuals with altered taste or smell perception only. Our results suggest an association between chemosensory function and blood pressure. Copyright © 2018 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.
Differential high pressure survival in stationary-phase Escherichia coli MG1655
NASA Astrophysics Data System (ADS)
Griffin, Patrick L.; Kish, Adrienne; Steele, Andrew; Hemley, Russell J.
2011-06-01
Hydrostatic pressure exerts a profound influence on nearly all facets of cellular structure and function with exposures to sufficiently high pressure leading to microbial inactivation. We report the first observation of a persistent, pressure-resistant subpopulation within stationary-phase samples of Escherichia coli MG1655, a mesophilic bacterium adapted to surface pressure. This high pressure-resistant subpopulation exhibits pressure survival ranging from 0.6 to 2.0 orders of magnitude greater survival than high pressure treatments at pressures of 225-400 MPa. We also examine some aspects of pressure treatment protocol that may influence the measurements of high pressure survival.
Gentles, Dudley; Metcalf, Patricia; Dyall, Lorna; Scragg, Robert; Black, Peter; Schaaf, David; Sundborn, Gerhard; Jackson, Rod
2006-11-17
To estimate ethnic-specific raised blood pressure (RBP) prevalences, blood pressure levels, and associations of systolic blood pressure (SBP) in the Auckland region. A cross-sectional survey of adults aged between 35-74 years in the Auckland region. There were 1006 Maori, 996 Pacific people (mostly of Samoan, Tongan, Niuean, or Cook Islands origin), and 2021 Others (mainly Europeans). Approximately 1 in 3 Maori and Pacific people had RBP (defined arbitrarily as greater than and equal to 140/90 mmHg or on blood pressure-lowering treatment), compared to 1 in 5 Others. The prevalences of RBP (adjusted for age and gender) were: Maori 37%, Pacific people 38%, and Others 22%. Maori and Pacific people had higher average systolic and diastolic blood pressure levels than Others (adjusted for age and gender). This difference became non-significant when adjusted for body mass index (BMI). SBP was (on average) higher for: male gender, increased age, increased BMI, no tertiary education, high pulse rate, high cholesterol, high triglycerides, those on current blood pressure-lowering medication. SBP was (on average) lower for current cigarette smokers. Average blood pressure levels and the prevalences of RBP were higher in Pacific people and Maori compared to Others. BMI was identified as the major modifiable factor.
Chen, Zhengming; Smith, Margaret; Du, Huaidong; Guo, Yu; Clarke, Robert; Bian, Zheng; Collins, Rory; Chen, Junshi; Qian, Yijian; Wang, Xiaoping; Chen, Xiaofang; Tian, Xiaocao; Wang, Xiaohuan; Peto, Richard; Li, Liming
2015-08-01
Greater adiposity is associated with higher blood pressure. Substantial uncertainty remains, however, about which measures of adiposity most strongly predict blood pressure and whether these associations differ materially between populations. We examined cross-sectional data on 500 000 adults recruited from 10 diverse localities across China during 2004-08. Multiple linear regression was used to estimate the effects on systolic blood pressure (SBP) of general adiposity [e.g. body mass index (BMI), body fat percentage, height-adjusted weight] vs central adiposity [e.g. waist circumference (WC), hip circumference (HC), waist-hip ratio (WHR)], before and after adjustment for each other. The main analyses excluded those reported taking any antihypertensive medication, and were adjusted for age, region and education. The overall mean [standard deviation (SD)] BMI was 23.6 (3.3) kg/m(2) and mean WC was 80.0 (9.5) cm. The differences in SBP (men/women, mmHg) per 1SD higher general adiposity (height-adjusted weight: 6.6/5.6; BMI: 5.5/4.9; body fat percentage: 5.5/5.0) were greater than for central adiposity (WC: 5.0/4.3; HC: 4.8/4.1; WHR: 3.7/3.2), with a 10 kg/m(2) greater BMI being associated on average with 16 (men/women: 17/14) mmHg higher SBP. The associations of blood pressure with measures of general adiposity were not materially altered by adjusting for WC and HC, but those for central adiposity were significantly attenuated after adjusting for BMI (WC: 1.1/0.7; HC: 0.3/-0.2; WHR: 0.6/0.6). In adult Chinese, blood pressure is more strongly associated with general adiposity than with central adiposity, and the associations with BMI were about 50% stronger than those observed in Western populations. © The Author 2015. Published by Oxford University Press on behalf of the International Epidemiological Association.
Low pressure treatments for codling moth on fresh fruits
USDA-ARS?s Scientific Manuscript database
The primary phytosanitary treatment used for fresh fruits exported to markets requiring quarantine protocols is fumigation with methyl bromide. Quarantine and pre-shipment (QPS) treatments are currently allowable under the Montreal Protocol, but there is growing concern that the QPS exemption will e...
Ultrastructural localization of proteins involved in sea urchin biomineralization.
Ameye, L; Hermann, R; Killian, C; Wilt, F; Dubois, P
1999-09-01
Three skeletal tissues of the adult echinoid Paracentrotus lividus (the pedicellaria primordium, the test, and the tooth) were immunolabeled with three sera raised against the total mineralization organic matrix and two specific matrix proteins (SM30 and SM50) from the embryo of the echinoid Strongylocentrotus purpuratus. Two conventional chemical fixation protocols and two high-pressure freezing/freeze-substitution protocols were tested. One conventional protocol is recommended for its good preservation of the ultrastructure, and one high-pressure freezing/freeze-substitution protocol is recommended for its good retention of antigenicity. Immunolabeling was obtained in the three adult tissues. It was confined to the active skeleton-forming cells and to the structured organic matrix. The results indicate that the matrix proteins follow the classical routes of secretory protein assembly and export and suggest that SM30 and SM50 are a part of the tridimensional network formed by the organic matrix before the onset of mineralization. They show that the genetic program of part of skeletogenesis is conserved among different calcification models and developmental stages.
Kwong, Enid Wy; Hung, Maria Sy; Woo, Kevin
2016-11-25
A need exits to develop a protocol for preventing pressure ulcers (PUs) in private for-profit nursing homes in Hong Kong, where the incidence of PUs is relatively high and which have high proportion of non-professional care staff. The implementation of such protocol would involve changes in the practice of care, likely evoking feelings of fear and uncertainty that may become a barrier to staff adherence. We thus adopted the Systems Model of Action Research in this study to manage the process of change for improving PU prevention care and to develop a pressure ulcer prevention protocol for private for-profit nursing homes. A total of 474 residents and care staff who were health workers, personal care workers, and/or nurses from four private, for-profit nursing homes in Hong Kong participated in this study. Three cyclic stages and steps, namely, unfreezing (planning), changing (action), and refreezing (results) were carried out. During each cycle, focus group interviews, field observations of the care staff's practices and inspections of the skin of the residents for pressure ulcers were conducted to evaluate the implementation of the protocol. Qualitative content analysis was adopted to analyse the data. The data and methodological triangulation used in this study increased the credibility and validity of the results. The following nine themes emerged from this study: prevention practices after the occurrence of PUs, the improper use of pressure ulcer prevention materials, non-compliance with several prevention practices, improper prevention practices, the perception that the preventive care was being performed correctly, inadequate readiness to use the risk assessment tool, an undesirable environment, the supplying of unfavorable resources, and various management styles in the homes with or without nurses. At the end of the third cycle, the changes that were identified included improved compliance with the revised risk assessment method, the timely and appropriate use of PU prevention materials, the empowering of staff to improve the quality of PU care, and improved home management. Through the action research approach, the care staff were empowered and their PU prevention care practices had improved, which contributed to the decreased incidence of pressure ulcers. A PU prevention protocol that was accepted by the staff was finally developed as the standard of care for such homes.
Nanowire growth kinetics in aberration corrected environmental transmission electron microscopy
Chou, Yi -Chia; Panciera, Federico; Reuter, Mark C.; ...
2016-03-15
Here, we visualize atomic level dynamics during Si nanowire growth using aberration corrected environmental transmission electron microscopy, and compare with lower pressure results from ultra-high vacuum microscopy. We discuss the importance of higher pressure observations for understanding growth mechanisms and describe protocols to minimize effects of the higher pressure background gas.
Therapeutic benefit of internet-based lifestyle counselling for hypertension.
Nolan, Robert P; Liu, Sam; Shoemaker, J Kevin; Hachinski, Vladimir; Lynn, Hazel; Mikulis, David J; Wennberg, Richard A; Moy Lum-Kwong, Margaret; Zbib, Ahmad
2012-05-01
Preventive electronic (e)-counselling has been shown to reduce cardiovascular risk factors. However, heterogeneity in outcomes is commonly reported due to differences in e-protocols. We incorporated key features of an established behavioural therapy, motivational interviewing, to help standardize e-counselling in order to reduce blood pressure in patients with hypertension. Subjects (n = 387, mean age = 56 years, 59% female, 72% taking ≥ 1 antihypertensive drug) were diagnosed with stage 1 or 2 hypertension. Subjects were randomized to a 4-month protocol of e-counselling (beta version of the "Blood Pressure Action Plan", Heart and Stroke Foundation of Canada) vs waitlist control (general e-information on heart-healthy living). Outcomes were systolic, diastolic, and pulse pressures, and total lipoprotein cholesterol after treatment. Intention to treat analysis did not find a significant group difference in outcomes due to contamination across the 2 arms of this trial. However, per protocol analysis indicated that subjects receiving ≥ 8 e-counselling messages (a priori therapeutic dose) vs 0 e-counselling messages (control) demonstrated greater reduction in systolic blood pressure (mean, -8.9 mm Hg; 95% confidence interval [CI], -11.5 to -6.4 vs -5.0 mm Hg; 95% CI, -6.7 to -3.3, P = 0.03), pulse pressure (-6.1 mm Hg; 95% CI, -8.1 to -4.1 vs -3.1 mm Hg; 95% CI, -4.3 to -1.8, P = 0.02) and total cholesterol (-0.24 mmol/L; 95% CI, -0.43 to -0.06 vs 0.05 mmol/L; 95% CI, -0.06 to 0.16, P = 0.03), but not diastolic blood pressure. These findings support the merit of evaluating whether e-counselling can improve blood pressure control and reduce cardiovascular risk over the long-term. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Koudryavtcev, Sergey A; Lazarev, Vyacheslav M
2011-01-01
Automatic blood pressure (BP) measuring devices are more and more often used in BP self-checks and in 24-hour BP monitoring. Nowadays, 24-hour BP monitoring is a necessary procedure in arterial hypertension treatment. The aim of this study was to validate the BPLab(®) ambulatory blood pressure monitor according to the European standard BS EN 1060-4:2004 and the British Hypertension Society (BHS) protocol, as well as to work out solutions regarding the suitability of using this device in clinical practice. A group of 85 patients of both sexes and different ages, who voluntarily agreed to take part in the tests and were given detailed instructions on the measurement technique were recruited for this study. The results of the BP measurement obtained by a qualified operator using the BPLab(®) device were compared with the BP values measured using the Korotkov auscultatory method. Data were obtained simultaneously by two experts with experience of over 10 years and had completed a noninvasive BP measurement standardization training course. Discrepancies in the systolic and diastolic BP measurements (N = 510; 255 for each expert) were analyzed according to the criteria specified in the BHS-93 protocol. The device passed the requirements of the European Standard BS EN 1060-4:2004 and was graded 'A' according to the criteria of the BHS protocol for both systolic BP and diastolic BP. The BPLab(®) 24-hour ambulatory blood pressure monitoring device may be recommended for extensive clinical use.
A neutron spectrometer based on temperature variations in superheated drop compositions
NASA Astrophysics Data System (ADS)
Apfel, Robert E.; d'Errico, Francesco
2002-01-01
The response of superheated drop detectors (SDDs) to neutron radiation varies in a self-consistent manner with variations in temperature and pressure, making such compositions suitable for neutron spectrometry. The advantage of this approach is that the response functions of candidate materials versus energy as the temperature or pressure is varied are nested and have distinct thresholds, with no thermal neutron response. These characteristics permit unfolding without the uncertainties associated with other spectrometry techniques, where multiple solutions are possible, thus requiring an initial guess of the spectrum. A spectrometer was developed based on the well-established technology for acoustic sensing of bubble events interfaced with a proportional-integral-derivative temperature controller. The active monitor for neutrons, called REMbrandt™, was used as the platform for controlling temperature on a SDD probe and for data acquisition, thereby automating the process of measuring the neutron energy spectrum. The new instrument, called REM-SPEC™, implements and automates the original BINS approach: it adjusts the temperature of the SDD vial in increasing steps and measures the bubble event rate at each step. By using two distinct SDD materials with overlapping responses, the 0.1-20 MeV range of energies relevant to practical spectrometry is readily covered. Initial experiments with an Am-Be source validate the operational protocols of this device.
A Push-pull Protocol to Reduce Colonization of Bird Nest Boxes by Honey Bees.
Efstathion, Caroline A; Kern, William H
2016-09-04
Introduction of the invasive Africanized honey bee (AHB) into the Neotropics is a serious problem for many cavity nesting birds, specifically parrots. These bees select cavities that are suitable nest sites for birds, resulting in competition. The difficulty of removing bees and their defensive behavior makes a prevention protocol necessary. Here, we describe a push-pull integrated pest management protocol to deter bees from inhabiting bird boxes by applying a bird safe insecticide, permethrin, to repel bees from nest boxes, while simultaneously attracting them to pheromone-baited swarm traps. Shown here is an example experiment using Barn Owl nest boxes. This protocol successfully reduced colonization of Barn Owl nest boxes by Africanized honey bees. This protocol is flexible, allowing adjustments to accommodate a wide range of bird species and habitats. This protocol could benefit conservation efforts where AHB are located.
Automatic efficiency optimization of an axial compressor with adjustable inlet guide vanes
NASA Astrophysics Data System (ADS)
Li, Jichao; Lin, Feng; Nie, Chaoqun; Chen, Jingyi
2012-04-01
The inlet attack angle of rotor blade reasonably can be adjusted with the change of the stagger angle of inlet guide vane (IGV); so the efficiency of each condition will be affected. For the purpose to improve the efficiency, the DSP (Digital Signal Processor) controller is designed to adjust the stagger angle of IGV automatically in order to optimize the efficiency at any operating condition. The A/D signal collection includes inlet static pressure, outlet static pressure, outlet total pressure, rotor speed and torque signal, the efficiency can be calculated in the DSP, and the angle signal for the stepping motor which control the IGV will be sent out from the D/A. Experimental investigations are performed in a three-stage, low-speed axial compressor with variable inlet guide vanes. It is demonstrated that the DSP designed can well adjust the stagger angle of IGV online, the efficiency under different conditions can be optimized. This establishment of DSP online adjustment scheme may provide a practical solution for improving performance of multi-stage axial flow compressor when its operating condition is varied.
[Water parameters of desert xeric shrubs in west Erdos region].
Li, Xiao; Wang, Ying-chun; Zheng, Rong
2007-05-01
By using PV technique, this paper studied the turgor pressure (psi P), cell elastic modulus (epsilon), and relative cell volume (RCV) of super xerophytes Potaninia mongolica, Reaumuria soongorica, Tetraena mongolica and Zygophyllum xanthoxylon in west Alashan, with the relationships among the parameters analyzed. The results showed that R. soongorica had the strongest ability to maintain maximum turgor pressure (a = 2.4593). The four plants maintained their turgor pressure by different ways, i.e., P. mongolica maintained it by elastic adjustment (epsilon max = 8.4005 MPa), R. soongorica by osmotic adjustment (psi pi100 = -3.1302 MPa; psi0 = -3.5074 MPa), T. mongolica by both osmotic and elastic adjustment, and Z. xanthoxylon by osmotic adjustment, which had weak adjustment ability. The cell wall of P. mongolica was soft and highly elastic, benefiting to the water absorption by root and stem and to the fast water transmission. T. mongolica also had relatively soft and high elastic cell wall, and its psi P, and epsilon changed slowly with decreasing RCV, suggesting that this plant had strong ability of holding water and resisting dehydration.
Adams, Jenny; Pullum, Gwen; Stafford, Pamala; Hanners, Nava; Hartman, Julie; Strauss, Danielle; Hubbard, Matt; Lawrence, Anne; Anderson, Valerie; McCullough, Tiffany
2008-01-01
Physician advice and restrictions to patients following a cardiac event can, in some instances, lead patients to be fearful regarding their activities even to the point of inactivity. The purpose of this study was to test whether lawn mowing, one of the activities most strongly discouraged after coronary artery bypass surgery, could be safely performed in a supervised setting. Subjects participated in a 6-session simulated lawn-mowing protocol, calibrated to match the push and pull forces of using an outdoor nonpropelled lawn mower. Plain chest radiographs were taken before and after the protocol period. During each session, subjects' sternums were carefully palpated and electrocardiograms, heart rates, and blood pressures were monitored. None of the 13 subjects experienced adverse arrhythmia events or detrimental heart rate, blood pressure, or sternal palpation findings that led to study discontinuation. The radiographs taken after protocol completion showed stable sternal wires with no evidence of sternal dehiscence. Simulated lawn mowing did not negatively affect the sternal incision, electrocardiogram findings, blood pressure, or heart rate in this small sample.
Ascending Aortic Dimensions in Former National Football League Athletes.
Gentry, James L; Carruthers, David; Joshi, Parag H; Maroules, Christopher D; Ayers, Colby R; de Lemos, James A; Aagaard, Philip; Hachamovitch, Rory; Desai, Milind Y; Roselli, Eric E; Dunn, Reginald E; Alexander, Kezia; Lincoln, Andrew E; Tucker, Andrew M; Phelan, Dermot M
2017-11-01
Ascending aortic dimensions are slightly larger in young competitive athletes compared with sedentary controls, but rarely >40 mm. Whether this finding translates to aortic enlargement in older, former athletes is unknown. This cross-sectional study involved a sample of 206 former National Football League (NFL) athletes compared with 759 male subjects from the DHS-2 (Dallas Heart Study-2; mean age of 57.1 and 53.6 years, respectively, P <0.0001; body surface area of 2.4 and 2.1 m 2 , respectively, P <0.0001). Midascending aortic dimensions were obtained from computed tomographic scans performed as part of a NFL screening protocol or as part of the DHS. Compared with a population-based control group, former NFL athletes had significantly larger ascending aortic diameters (38±5 versus 34±4 mm; P <0.0001). A significantly higher proportion of former NFL athletes had an aorta of >40 mm (29.6% versus 8.6%; P <0.0001). After adjusting for age, race, body surface area, systolic blood pressure, history of hypertension, current smoking, diabetes mellitus, and lipid profile, the former NFL athletes still had significantly larger ascending aortas ( P <0.0001). Former NFL athletes were twice as likely to have an aorta >40 mm after adjusting for the same parameters. Ascending aortic dimensions were significantly larger in a sample of former NFL athletes after adjusting for their size, age, race, and cardiac risk factors. Whether this translates to an increased risk is unknown and requires further evaluation. © 2017 American Heart Association, Inc.
Umesawa, Mitsumasa; Yamagishi, Kazumasa; Noda, Hiroyuki; Ikeda, Ai; Sawachi, Shinobu; Muraki, Isao; Chei, Choy-Lye; Cui, Renzhe; Nagao, Masanori; Ohira, Tetsuya; Sankai, Tomoko; Tanigawa, Takeshi; Kitamura, Akihiko; Kiyama, Masahiko; Iso, Hiroyasu
2016-03-05
Although several cross-sectional and intervention studies showed that sodium intake or excretion was associated with blood pressure levels, no prospective study has examined the long-term association between sodium excretion in spot urine and blood pressure changes. We conducted a prospective study of 889 normotensive subjects (295 men and 594 women, mean age 57.3 years) who underwent the baseline survey including spot urine test in 2005 and the follow-up survey in 2009 to 2011 (mean follow-up period: 5.8 years). We examined the association between sodium concentration in spot urine, a validated index of sodium excretion occurring over 24-h, and blood pressure changes between baseline and follow-up survey in all, non-overweight (body mass index(BMI) ≤ 25 kg/m(2)) and overweight normotensives. For all subjects, sodium concentrations in spot urine were not associated with either systolic or diastolic blood pressure changes. When stratified by BMI at baseline survey, sodium concentrations were positively associated with systolic blood pressure changes in non-overweight subjects, but not in overweight subjects. After adjustment for age, sex, BMI, alcohol intake status, current smoking and estimated glomerular filtration rate, the multivariable-adjusted mean values of the systolic blood pressure change among non-overweight subjects was +7.3 mmHg in the highest quartiles of sodium concentrations, while it was +3.9 mmHg in the lowest quartile (P for difference = 0.021, P for trend = 0.040). After further adjustment of baseline blood pressure levels, the association was slightly weakened; the multivariable-adjusted mean values of the systolic blood pressure changes were +7.0 mmHg and +4.2 mmHg (P for difference = 0.047, P for trend = 0.071). High sodium concentrations in spot urine were associated with subsequent systolic blood pressure increases among non-overweight normotensive individuals. (272 words).
Carl, Daniel L; Boyne, Pierce; Rockwell, Bradley; Gerson, Myron; Khoury, Jane; Kissela, Brett; Dunning, Kari
2017-03-01
The purpose of this study was to assess safety via electrocardiographic (ECG), blood pressure (BP), heart rate (HR), and orthopedic responses to 3 different high-intensity interval training (HIIT) protocols in persons with stroke. Eighteen participants (10 male; 61.9 + 8.3 years of age; 5.8 + 4.2 years poststroke) completed a symptom-limited graded exercise test (GXT) with ECG monitoring to screen for eligibility and determine HR peak. The 3 HIIT protocols involved repeated 30 s bursts of treadmill walking at maximum speed alternated with rest periods of 30 s (P30), 1 min (P60), or 2 min (P120). Sessions were performed in random order and included 5 min warm up, 20 min HIIT, and 5 min cool down. Variables measured included ECG activity, BP, HR, signs and symptoms of cardiovascular intolerance, and orthopedic concerns. Generalized linear mixed models and Tukey-Kramer adjustment were used to compare protocols using p < 0.05. No signs or symptoms of cardiovascular intolerance, significant arrhythmias, ST segment changes, or orthopedic responses resulted in early termination of any HIIT session. HIIT elicited HRs in excess of 88% of measured HR peak including 6 (P30), 8 (P60), and 2 (P120) participants eliciting a HR response above their GXT HR peak . Both maximum BP and HR were significantly higher in P30 and P60 relative to P120. Preliminary data indicate that persons with chronic stroke who have been prescreened with an ECG stress test, a symptom-limited GXT, and a harness for fall protection may safely participate in HIIT, generating substantially higher HRs than what is seen in traditional moderate intensity training.
Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark
2018-05-01
Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo
2014-02-01
The objective of this study was to determine the accuracy of the A&D BP UA-651 device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Device evaluation was carried out in 33 patients. The mean age of the patients was 48.3±15.5 years, the mean systolic BP was 138.3±24.9 mmHg (range 90-180), the mean diastolic BP was 88.3±13.8 mmHg (range 60-108), and the mean arm circumference was 28.6±3.4 cm (range 23-36). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device underestimated the systolic BP by 0.4±4.4 mmHg and diastolic BP by 1.3±3.5 mmHg. The device-observer discrepancies were unrelated to patients' clinical characteristics. These data show that the A&D BP UA-651 device fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.
Maximal inspiratory pressure is influenced by intensity of the warm-up protocol.
Arend, Mati; Kivastik, Jana; Mäestu, Jarek
2016-08-01
The aim of the study was to compare the effect of inspiratory muscle warm-up protocols with different intensities and breathing repetitions on maximal inspiratory pressure (MIP). Ten healthy and recreationally active men (183.3±5.5cm, 83.7±7.8kg, 26.4±4.1years) completed four different inspiratory muscle (IM) warm-up protocols (2×30 inspirations at 40% MIP, 2×12 inspirations at 60% MIP, 2×6 inspirations at 80% MIP, 2×30 inspirations at 15% MIP) on separate, randomly assigned visits. Pre-post values of MIP using MicroRPM (Micro Medical, Kent, UK) showed a significant increase in the mean values after the IM warm-up (POWERbreathe(®) K1, Warwickshire, UK) with 40% MIP and 60% MIP warm-up protocols, when MIP increased by 7cm H2O (95% CI: 0.10…13.89) (p=0.047) and by 6.4cm H2O (95% CI: 2.98…13.83) (p=0.027), respectively. In conclusion, a higher intensity inspiratory muscle warm-up protocol (2×12 breaths at 60% of MIP) can increase IM strength. Copyright © 2016 Elsevier B.V. All rights reserved.
Taing, Kevin Y; Farkouh, Michael E; Moineddin, Rahim; Tu, Jack V; Jha, Prabhat
2016-12-01
A determinant of blood pressure is adiposity; however, there are uncertainties surrounding whether general or central adiposity is the more important determinant of blood pressure. Further, inconsistent results exist for the relationships of anthropometric measures with blood pressure and hypertension, and whether these relationships differ substantially by age and sex is unclear. We aimed to elucidate the associations of anthropometric measures of general and central adiposity with blood pressure and hypertension, and determine the effect of age and sex on these relationships. We used cross-sectional data from the Centre for Global Health Research health check-up survey conducted during 2006-2007 of the general population in India (n = 7 601; age 18-59 years). We examined the associations of anthropometric measures (body mass index, waist circumference, hip circumference, waist-hip ratio, waist-height ratio) with blood pressure components (systolic pressure, diastolic pressure, pulse pressure, mean arterial pressure, mid-blood pressure) and hypertension within four (18-29 years, 30-39 years, 40-49 years, 50-59 years) age groups, by sex. We adjusted all analyses for education and location, with further adjustments, variously, for either a measure of central (waist circumference) or general (body mass index) adiposity. On average, every 5 kg/m 2 greater body mass index or 10 cm wider waist circumference was associated with a 5 and 4 mmHg higher systolic blood pressure, respectively. When considered separately, each anthropometric measure was strongly and positively associated with most blood pressure components in all age groups, and for both sexes. However, with few exceptions, when considered jointly (body mass index adjusted for waist circumference), the associations of body mass index with blood pressure components and hypertension were greatly diminished for both sexes, and particularly in the ≥30 years age groups. By contrast, further adjustment of waist circumference for body mass index did not materially alter the associations of waist circumference with blood pressure components and hypertension. Our findings indicate that central adiposity, as assessed with anthropometric measures, may be a more important determinant of blood pressure and hypertension than general adiposity for adults in India.
Franssen, Marloes; Farmer, Andrew; Grant, Sabrina; Greenfield, Sheila; Heneghan, Carl; Hobbs, Richard; Hodgkinson, James; Jowett, Susan; Mant, Jonathan; Martin, Una; Milner, Siobhan; Monahan, Mark; Ogburn, Emma; Perera-Salazar, Rafael; Schwartz, Claire; Yu, Ly-Mee; McManus, Richard J
2017-02-13
Self-monitoring of hypertension is associated with lower systolic blood pressure (SBP). However, evidence for the use of self-monitoring to titrate antihypertensive medication by physicians is equivocal. Furthermore, there is some evidence for the efficacy of telemonitoring in the management of hypertension but it is not clear what this adds over and above self-monitoring. This trial aims to evaluate whether GP led antihypertensive titration using self-monitoring results in lower SBP compared to usual care and whether telemonitoring adds anything to self-monitoring alone. This will be a pragmatic primary care based, unblinded, randomised controlled trial of self-monitoring of BP with or without telemonitoring compared to usual care. Eligible patients will have poorly controlled hypertension (>140/90 mmHg) and will be recruited from primary care. Participants will be individually randomised to either usual care, self-monitoring alone, or self-monitoring with telemonitoring. The primary outcome of the trial will be difference in clinic SBP between intervention and control groups at 12 months adjusted for baseline SBP, gender, BP target and practice. At least 1110 patients will be sufficient to detect a difference in SBP between self-monitoring with or without telemonitoring and usual care of 5 mmHg with 90% power with an adjusted alpha of 0.017 (2-sided) to adjust for all three pairwise comparisons. Other outcomes will include adherence of anti-hypertensive medication, lifestyle behaviours, health-related quality of life, and adverse events. An economic analysis will consider both within trial costs and a model extrapolating the results thereafter. A qualitative sub study will gain insights into the views, experiences and decision making processes of patients and health care professionals focusing on the acceptability of self-monitoring and telemonitoring in the routine management of hypertension. The results of the trial will be directly applicable to primary care in the UK. If successful, self-monitoring of BP in people with hypertension would be applicable to hundreds of thousands of individuals in the UK. ISRCTN 83571366 . Registered 17 July 2014.
Comparison of Three Exit-Area Control Devices on an N.A.C.A. Cowling, Special Report
NASA Technical Reports Server (NTRS)
McHugh, James G.
1940-01-01
Adjustable cowling flaps, an adjustable-length cowling skirt, and a bottom opening with adjustable flap were tested as means of controlling the rate of cooling-air flow through an air-cooled radial-engine cowling. The devices were tested in the NACA 20-foot tunnel on a model wing-nacelle-propeller combination, through an airspeed range of 20 to 80 miles per hour, and with the propeller blade angle set 23 degrees at 0.75 of the tip radius. The resistance of the engine to air flow through the cowling was simulated by a perforated plate. The results indicated that the adjustable cowling flap and the bottom opening with adjustable flap were about equally effective on the basis of pressure drop obtainable and that both were more effective means of increasing the pressure drop through the cowling than the adjustable-length skirt. At conditions of equal cooling-air flow, the net efficiency obtained with the adjustable cowling flaps and the adjustable-length cowling skirt was about 1% greater than the net efficiency obtained with the bottom opening with adjustable flap.
Wound-healing outcomes using standardized assessment and care in clinical practice.
Bolton, Laura; McNees, Patrick; van Rijswijk, Lia; de Leon, Jean; Lyder, Courtney; Kobza, Laura; Edman, Kelly; Scheurich, Anne; Shannon, Ron; Toth, Michelle
2004-01-01
Wound-healing outcomes applying standardized protocols have typically been measured within controlled clinical trials, not natural settings. Standardized protocols of wound care have been validated for clinical use, creating an opportunity to measure the resulting outcomes. Wound-healing outcomes were explored during clinical use of standardized validated protocols of care based on patient and wound assessments. This was a prospective multicenter study of wound-healing outcomes management in real-world clinical practice. Healing outcomes from March 26 to October 31, 2001, were recorded on patients in 3 long-term care facilities, 1 long-term acute care hospital, and 12 home care agencies for wounds selected by staff to receive care based on computer-generated validated wound care algorithms. After diagnosis, wound dimensions and status were assessed using a tool adapted from the Pressure Sore Status Toolfor use on all wounds. Wound, ostomy, and continence nursing professionals accessed consistent protocols of care, via telemedicine in home care or paper forms in long-term care. A physician entered assessments into a desktop computer in the wound clinic. Based on evidence that healing proceeds faster with fewer infections in environments without gauze, the protocols generally avoided gauze dressings. Most of the 767 wounds selected to receive the standardized-protocols of care were stage III-IV pressure ulcers (n = 373; mean healing time 62 days) or full-thickness venous ulcers (n = 124; mean healing time 57 days). Partial-thickness wounds healed faster than same-etiology full-thickness wounds. These results provide benchmarks for natural-setting healing outcomes and help to define and address wound care challenges. Outcomes primarily using nongauze protocols of care matched or surpassed best previously published results on similar wounds using gauze-based protocols of care, including protocols applying gauze impregnated with growth factors or other agents.
[Treatment of pubic osteomyelitis secondary to pressure sores].
Brunel, Anne-Sophie; Téot, Luc; Lamy, Brigitte; Masson, Raphaël; Morquin, David; Reynes, Jacques; Le Moing, Vincent
2014-01-01
There is no consensus regarding the diagnostic and therapeutic strategy for pubic osteomyelitis secondary to pelvic pressure sores. Diagnosis is often difficult and bone biopsies with microbiological and anatomical-pathological examination remain the gold standard. The rate of cicatrisation of pressure sores is low. Cleansing and negative pressure treatment are key elements of the treatment. Optimising the care management with medical-surgical collaboration is being studied in the Ostear protocol.
Piotrowski-Daspit, Alexandra S; Simi, Allison K; Pang, Mei-Fong; Tien, Joe; Nelson, Celeste M
2017-01-01
Cells are surrounded by mechanical stimuli in their microenvironment. It is important to determine how cells respond to the mechanical information that surrounds them in order to understand both development and disease progression, as well as to be able to predict cell behavior in response to physical stimuli. Here we describe a protocol to determine the effects of interstitial fluid flow on the migratory behavior of an aggregate of epithelial cells in a three-dimensional (3D) culture model. This protocol includes detailed methods for the fabrication of a 3D cell culture chamber with hydrostatic pressure control, the culture of epithelial cells as an aggregate in a collagen gel, and the analysis of collective cell behavior in response to pressure-driven flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romberger, Jeff
An adjustable-speed drive (ASD) includes all devices that vary the speed of a rotating load, including those that vary the motor speed and linkage devices that allow constant motor speed while varying the load speed. The Variable Frequency Drive Evaluation Protocol presented here addresses evaluation issues for variable-frequency drives (VFDs) installed on commercial and industrial motor-driven centrifugal fans and pumps for which torque varies with speed. Constant torque load applications, such as those for positive displacement pumps, are not covered by this protocol.
Gonzaga, Luana Almeida; Vanderlei, Luiz Carlos Marques; Gomes, Rayana Loch; Valenti, Vitor Engrácia
2017-10-26
The post-exercise recovery period is associated with changes in autonomic modulation, which can promote an intercurrent-favorable environment. Caffeine has the ability to release catecholamines, but its effects after exercises is little explored. The present study aims to evaluate the acute effects of caffeine on the autonomic control and cardiorespiratory parameters after moderate intensity aerobic exercise. 32 young males (23,59 ± 3,45 years) were submitted to two protocols: Placebo and Caffeine, consisting of 15 minutes of rest, 30 minutes of exercise on a treadmill to 60% on VO2peak, followed by 60 minutes of recovery. Heart rate variability indices and cardiorespiratory parameters were determined at different times during the protocols. The RMSSD and SD1 indices recovered faster in placebo (p < 0.05). The systolic blood pressure differences were found from the 1st to the 5th minute of recovery with the caffeine protocol and from the 1st and 3rd minute with the placebo, whereas, for diastolic blood pressure, significant differences (p < 0.0001) were observed only for the caffeine protocol at the 1st and 3rd minutes of recovery. Caffeine was shown to be capable of delaying parasympathetic recovery but did not influence the behavior of the respiratory rate, oxygen saturation or frequency-domain HRV indices.
Constitutive properties of adult mammalian cardiac muscle cells
NASA Technical Reports Server (NTRS)
Zile, M. R.; Richardson, K.; Cowles, M. K.; Buckley, J. M.; Koide, M.; Cowles, B. A.; Gharpuray, V.; Cooper, G. 4th
1998-01-01
BACKGROUND: The purpose of this study was to determine whether changes in the constitutive properties of the cardiac muscle cell play a causative role in the development of diastolic dysfunction. METHODS AND RESULTS: Cardiocytes from normal and pressure-hypertrophied cats were embedded in an agarose gel, placed on a stretching device, and subjected to a change in stress (sigma), and resultant changes in cell strain (epsilon) were measured. These measurements were used to examine the passive elastic spring, viscous damping, and myofilament activation. The passive elastic spring was assessed in protocol A by increasing the sigma on the agarose gel at a constant rate to define the cardiocyte sigma-versus-epsilon relationship. Viscous damping was assessed in protocol B from the loop area between the cardiocyte sigma-versus-epsilon relationship during an increase and then a decrease in sigma. In both protocols, myofilament activation was minimized by a reduction in [Ca2+]i. Myofilament activation effects were assessed in protocol C by defining cardiocyte sigma versus epsilon during an increase in sigma with physiological [Ca2+]i. In protocol A, the cardiocyte sigma-versus-epsilon relationship was similar in normal and hypertrophied cells. In protocol B, the loop area was greater in hypertrophied than normal cardiocytes. In protocol C, the sigma-versus-epsilon relation in hypertrophied cardiocytes was shifted to the left compared with normal cells. CONCLUSIONS: Changes in viscous damping and myofilament activation in combination may cause pressure-hypertrophied cardiocytes to resist changes in shape during diastole and contribute to diastolic dysfunction.
Nobles, Carrie J; Mendola, Pauline; Mumford, Sunni L; Naimi, Ashley I; Yeung, Edwina H; Kim, Keewan; Park, Hyojun; Wilcox, Brian; Silver, Robert M; Perkins, Neil J; Sjaarda, Lindsey; Schisterman, Enrique F
2018-05-01
Elevated blood pressure in young adulthood is an early risk marker for cardiovascular disease. Despite a strong biological rationale, little research has evaluated whether incremental increases in preconception blood pressure have early consequences for reproductive health. We evaluated preconception blood pressure and fecundability, pregnancy loss, and live birth in the EAGeR trial (Effects of Aspirin on Gestational and Reproduction; 2007-2011), a randomized clinical trial of aspirin and reproductive outcomes among 1228 women attempting pregnancy with a history of pregnancy loss. Systolic and diastolic blood pressure were measured during preconception in the first observed menstrual cycle and in early pregnancy and used to derive mean arterial pressure. Fecundability was assessed as number of menstrual cycles until pregnancy, determined through human chorionic gonadotropin testing. Pregnancy loss included both human chorionic gonadotropin-detected and clinical losses. Analyses adjusted for treatment assignment, age, body mass index, race, marital status, smoking, parity, and time since last loss. Mean preconception systolic and diastolic blood pressure were 111.6 mm Hg (SD, 12.1) and 72.5 (SD, 9.4) mm Hg. Risk of pregnancy loss increased 18% per 10 mm Hg increase in diastolic blood pressure (95% confidence interval, 1.03-1.36) and 17% per 10 mm Hg increase in mean arterial pressure (95% confidence interval, 1.02-1.35) in adjusted analyses. Findings were similar for early pregnancy blood pressure. Preconception blood pressure was not related to fecundability or live birth in adjusted analyses. Findings suggest that preconception blood pressure among healthy women is associated with pregnancy loss, and lifestyle interventions targeting blood pressure among young women may favorably impact reproductive health. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00467363. © 2018 American Heart Association, Inc.
Mikkelsson, L; Kaprio, J; Kautiainen, H; Nupponen, H; Tikkanen, M J; Kujala, U M
2005-01-01
The aim was to study whether aerobic fitness measured by a maximal endurance running test at adolescence predicts prevalence of hypertension or blood pressure levels in adulthood. From the 413 (197 slow runners and 216 fast runners) participating in a 2000-meter running test at adolescence in 1976 and responding to a health and fitness questionnaire in 2001, 29 subjects (15 very slow runners and 14 very fast runners) participated in a clinical follow-up study in 2001. Compared to those who were fast runners in adolescence, those who were slow runners tended to have higher age-adjusted risk of hypertension at follow-up (OR 2.7, 95 % CI 0.9 to 7.5; p=0.07). The result persisted after further adjustment for body mass index at follow-up (OR 2.9, 95 % CI 1.0 to 8.3; p=0.05). Diastolic blood pressure was higher for very slow runners at adolescence compared to very fast runners, the age-adjusted mean diastolic blood pressure being 90 mm Hg (95 % CI 86 to 93) vs. 83 mm Hg (95 % CI 80 to 87), age-adjusted p=0.013. High endurance type fitness in adolescence predicts low risk of hypertension and low resting diastolic blood pressure levels in adult men.
Recovery of anhydrous hydrogen iodide
O'Keefe, Dennis R.; McCorkle, Jr., Kenneth H.; de Graaf, Johannes D.
1982-01-01
Relatively dry hydrogen iodide can be recovered from a mixture of HI, I.sub.2 and H.sub.2 O. After the composition of the mixture is adjusted so that the amounts of H.sub.2 O and I.sub.2 do not exceed certain maximum limits, subjection of the mixture to superatmospheric pressure in an amount equal to about the vapor pressure of HI at the temperature in question causes distinct liquid phases to appear. One of the liquid phases contains HI and not more than about 1 weight percent water. Often the adjustment in the composition will include the step of vaporization, and the distinct layers appear following the increase in pressure of the vapor mixture. Adjustment in the composition may also include the addition of an extraction agent, such as H.sub.3 PO.sub.4, and even though the adjusted composition mixture contains a significant amount of such an agent, the creation of the distinct liquid phases is not adversely affected.
Morton, Katherine; Stuart, Beth; Raftery, James; Bradbury, Katherine; Yao, Guiqing Lily; Zhu, Shihua; Little, Paul; Yardley, Lucy
2016-01-01
Introduction Self-management of hypertension, including self-monitoring and antihypertensive medication titration, lowers blood pressure (BP) at 1 year compared to usual care. The aim of the current trial is to assess the effectiveness of the Home and Online Management and Evaluation of Blood Pressure (HOME BP) intervention for the self-management of hypertension in primary care. Methods and analysis The HOME BP trial will be a randomised controlled trial comparing BP self-management—consisting of the HOME BP online digital intervention with self-monitoring, lifestyle advice and antihypertensive drug titration—with usual care for people with uncontrolled essential hypertension. Eligible patients will be recruited from primary care and randomised to usual care or to self-management using HOME BP. The primary outcome will be the difference in mean systolic BP (mm Hg) at 12-month follow-up between the intervention and control groups adjusting for baseline BP and covariates. Secondary outcomes (also adjusted for baseline and covariates where appropriate) will be differences in mean BP at 6 months and diastolic BP at 12 months; patient enablement; quality of life, and economic analyses including all key resources associated with the intervention and related services, adopting a broad societal perspective to include NHS, social care and patient costs, considered within trial and modelled with a lifetime horizon. Medication beliefs, adherence and changes; self-efficacy; perceived side effects and lifestyle changes will be measured for process analyses. Qualitative analyses will explore patient and healthcare professional experiences of HOME BP to gain insights into the factors affecting acceptability, feasibility and adherence. Ethics and dissemination This study has received NHS ethical approval (REC reference 15/SC/0082). The findings from HOME BP will be disseminated widely through peer-reviewed publications, scientific conferences and workshops. If successful, HOME BP will be directly applicable to UK primary care management of hypertension. Trial registration number ISRCTN13790648; pre-results. PMID:27821598
Valera, Beatriz; Dewailly, Eric; Poirier, Paul
2013-01-01
Epidemiological evidence suggests a negative impact of methylmercury (MeHg) on cardiovascular risk factors such as blood pressure (BP) and heart rate (HR). This issue is of concern in Arctic populations such as in the Inuit of Nunavik since this contaminant is accumulated in fish and marine mammals, which still represent the subsistence diet of this population. We examined the associations between MeHg and BP and resting HR among Inuit adults. The "Santé Quebec" health survey was conducted in 1992 in the 14 villages of Nunavik and a complete set of data was obtained for 313 Inuit adults≥18 years. Blood samples were collected in order to determine total mercury, lead, total polychlorinated biphenyls (PCBs), n-3 polyunsaturated fatty acids (PUFAs), fasting glucose and lipid profile while socio-demographic variables were obtained through questionnaires. Anthropometric measurements as well as BP and resting HR were obtained using standardised protocols. Pulse pressure (PP: systolic BP minus diastolic BP) was also calculated. Multiple linear regression was used in order to determine the change in the dependent variables associated with the quartiles of MeHg concentration, taking the quartile 1 as reference. The mean age of the participants was 38±14 years and the sample was composed of 132 men (42.2%) and 181 women (57.8%). MeHg geometric mean was 15.4 μg/L (95%CI: 13.9-17.0) and levels ranged from 0.8 to 112.0 μg/L. Resting HR increased linearly across quartiles of blood MeHg concentration after adjusting for confounders (p for trend=0.02). An increase of 6.9 beats per minute (bpm) between the 4th and 1st quartile was observed after adjusting for confounders. No significant association was observed between blood MeHg and systolic BP, diastolic BP or PP. MeHg was associated with increasing resting HR after considering traditional risk factors as well as other contaminants (lead and total PCBs) and n-3 PUFAs. In contrast, no significant association with blood pressure was observed in this study. Copyright © 2012 Elsevier Inc. All rights reserved.
Bobik, Krzysztof; Dunlap, John R.; Burch-Smith, Tessa M.
2014-01-01
Since the 1940s transmission electron microscopy (TEM) has been providing biologists with ultra-high resolution images of biological materials. Yet, because of laborious and time-consuming protocols that also demand experience in preparation of artifact-free samples, TEM is not considered a user-friendly technique. Traditional sample preparation for TEM used chemical fixatives to preserve cellular structures. High-pressure freezing is the cryofixation of biological samples under high pressures to produce very fast cooling rates, thereby restricting ice formation, which is detrimental to the integrity of cellular ultrastructure. High-pressure freezing and freeze substitution are currently the methods of choice for producing the highest quality morphology in resin sections for TEM. These methods minimize the artifacts normally associated with conventional processing for TEM of thin sections. After cryofixation the frozen water in the sample is replaced with liquid organic solvent at low temperatures, a process called freeze substitution. Freeze substitution is typically carried out over several days in dedicated, costly equipment. A recent innovation allows the process to be completed in three hours, instead of the usual two days. This is typically followed by several more days of sample preparation that includes infiltration and embedding in epoxy resins before sectioning. Here we present a protocol combining high-pressure freezing and quick freeze substitution that enables plant sample fixation to be accomplished within hours. The protocol can readily be adapted for working with other tissues or organisms. Plant tissues are of special concern because of the presence of aerated spaces and water-filled vacuoles that impede ice-free freezing of water. In addition, the process of chemical fixation is especially long in plants due to cell walls impeding the penetration of the chemicals to deep within the tissues. Plant tissues are therefore particularly challenging, but this protocol is reliable and produces samples of the highest quality. PMID:25350384
Are middle-age blood pressure levels related to color vision impairment? The Okubo Color Study.
Shoji, Takuhei; Sato, Hiroki; Chihara, Etsuo; Sakurai, Yutaka
2015-01-01
We sought to investigate the association between blood pressure levels and prevalence of acquired color vision impairment in middle-aged Japanese men. Participants underwent color vision testing, ophthalmological examination, standardized interview, physical record examination, and venous blood examination. Cardiovascular disease risk factors were determined based on blood and physical examination results and the interview. Logistic regression analysis was performed after adjusting for body mass index, systemic dyslipidemia, diabetes, cataract, glaucoma, smoking status, and drinking status. Of 1,042 men, 872 were eligible for the study, 130 failed the Lanthony 15-hue desaturated panel (D-15 DS) diagnosed as acquired color vision impairment 15-hue, and 31 failed the Farnsworth-Munsell 100-hue test diagnosed as acquired color vision impairment 100-hue. Diastolic blood pressure was significantly correlated with both acquired color vision impairment in 100-hue patients (adjusted odds ratio (OR) for 10-mm Hg increases = 1.42; 95% confidence interval (CI) = 1.00-2.02) and acquired color vision impairment in 15-hue patients (adjusted OR for 10-mm Hg increases = 1.25; 95% CI = 1.04-1.51). The multiple-adjusted ORs for acquired color vision impairment 100-hue patients and acquired color vision impairment 15-hue patients were 7.13 (95% CI = 1.72-27.88) and 4.37 (95% CI = 1.69-11.03), respectively, for the highest blood pressure category (systolic blood pressure ≥ 160 and diastolic blood pressure ≥ 100 mm Hg) compared with those for the lowest blood pressure category (systolic blood pressure <120 and diastolic blood pressure <80 mm Hg). Tests for trends were significant (P < 0.05) in both analyses. Hypertension in middle-aged men may negatively modify vision-associated neuronal function. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Adiposity and Blood Pressure in 110 000 Mexican Adults
Gnatiuc, Louisa; Halsey, Jim; Herrington, William G.; López-Cervantes, Malaquías; Lewington, Sarah; Collins, Rory; Tapia-Conyer, Roberto; Peto, Richard; Kuri-Morales, Pablo
2017-01-01
Previous studies have reached differing conclusions about the importance of general versus central markers of adiposity to blood pressure, leading to suggestions that population-specific adiposity thresholds may be needed. We examined the relevance of adiposity to blood pressure among 111 911 men and women who, when recruited into the Mexico City Prospective Study, were aged 35 to 89 years, had no chronic disease, and were not taking antihypertensives. Linear regression was used to estimate the effects on systolic and diastolic blood pressure of 2 markers of general adiposity (body mass index and height-adjusted weight) and 4 markers of central adiposity (waist circumference, hip circumference, waist:hip ratio, and waist:height ratio), adjusted for relevant confounders. Mean (SD) adiposity levels were: body mass index (28.7±4.5 kg/m2), height-adjusted weight (70.2±11.2 kg), waist circumference (93.3±10.6 cm), hip circumference (104.0±9.0 cm), waist:hip ratio (0.90±0.06), and waist:height ratio (0.60±0.07). Associations with blood pressure were linear with no threshold levels below which lower general or central adiposity was not associated with lower blood pressure. On average, each 1 SD higher measured adiposity marker was associated with a 3 mm Hg higher systolic blood pressure and 2 mm Hg higher diastolic blood pressure (SEs <0.1 mm Hg), but for the waist:hip ratio, associations were only approximately half as strong. General adiposity associations were independent of central adiposity, but central adiposity associations were substantially reduced by adjustment for general adiposity. Findings were similar for men and women. In Mexican adults, often overweight or obese, markers of general adiposity were stronger independent predictors of blood pressure than measured markers of central adiposity, with no threshold effects. PMID:28223471
Schell-Chaple, Hildy M; Liu, Kathleen D; Matthay, Michael A; Sessler, Daniel I; Puntillo, Kathleen A
2017-07-01
To determine the effects of IV acetaminophen on core body temperature, blood pressure, and heart rate in febrile critically ill patients. Randomized, double-blind, placebo-controlled clinical trial. Three adult ICUs at a large, urban, academic medical center. Forty critically ill adults with fever (core temperature, ≥ 38.3°C). An infusion of acetaminophen 1 g or saline placebo over 15 minutes. Core temperature and vital signs were measured at baseline and at 5-15-minute intervals for 4 hours after infusion of study drug. The primary outcome was time-weighted average core temperature adjusted for baseline temperature. Secondary outcomes included adjusted time-weighted average heart rate, blood pressure, and respiratory rate, along with changes-over-time for each. Baseline patient characteristics were similar in those given acetaminophen and placebo. Patients given acetaminophen had an adjusted time-weighted average temperature that was 0.47°C less than those given placebo (95% CI, -0.76 to -0.18; p = 0.002). The acetaminophen group had significantly lower adjusted time-weighted average systolic blood pressure (-17 mm Hg; 95% CI, -25 to -8; p < 0.001), mean arterial pressure (-7 mm Hg; 95% CI, -12 to -1; p = 0.02), and heart rate (-6 beats/min; 95% CI, -10 to -1; p = 0.03). Changes-over-time temperature, blood pressure, and heart rate outcomes were also significantly lower at 2 hours, but not at 4 hours. Among febrile critically ill adults, treatment with acetaminophen decreased temperature, blood pressure, and heart rate. IV acetaminophen thus produces modest fever reduction in critical care patients, along with clinically important reductions in blood pressure.
Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi
2016-08-01
The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.
Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel
2017-01-01
ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile. PMID:29340488
Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel
2017-01-01
To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.
Wu, Lili; Jiao, Yinghui; Wang, Chengdong; Chen, Lei; Di, Dalin; Zhang, Haiyan
2015-08-01
This study aimed to validate the Andon KD-5851 upper arm blood pressure (BP) monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 33 eligible participants were included in the study. Sequential measurements of BPs were performed using a mercury sphygmomanometer and the device, and the data analysis was carried out following precisely the ESH-IP revision 2010. The device had 82, 98, and 99 measurements within 5, 10, and 15 mmHg for systolic blood pressure and 85, 95, and 99 measurements for diastolic blood pressure, respectively. The average device-observer difference was -0.53±4.00 mmHg for systolic blood pressure and -1.15±4.06 mmHg for diastolic blood pressure. The device passed all the criteria according to the ESH-IP revision 2010. According to the validation results on the basis of the ESH-IP revision 2010, the Andon KD-5851 upper arm BP monitor can be recommended for self/home measurement in adults. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.
Choroidal Blood Flow Decreases with Age: An MRI Study
San Emeterio Nateras, Oscar; Harrison, Joseph M.; Muir, Eric R.; Zhang, Yi; Peng, Qi; Chalfin, Steven; Gutierrez, Juan E.; Johnson, Daniel A.; Kiel, Jeffrey W.; Duong, Timothy Q.
2014-01-01
Purpose To verify that a visual fixation protocol with cued eye blinks achieves sufficient stability for magnetic resonance imaging (MRI) blood-flow measurements and to determine if choroidal blood flow (ChBF) changes with age in humans. Methods The visual fixation stability achievable during an MRI scan was measured in five normal subjects using an eye-tracking camera outside the MRI scanner. Subjects were instructed to blink immediately after recorded MRI sound cues but to otherwise maintain stable visual fixation on a small target. Using this fixation protocol, ChBF was measured with MRI using a 3 Tesla clinical scanner in 17 normal subjects (24–68 years old). Arterial and intraocular pressures (IOP) were measured to calculate perfusion pressure in the same subjects. Results The mean temporal fluctuations (standard deviation) of the horizontal and vertical displacements were 29 ± 9 μm and 38 ± 11 μm within individual fixation periods, and 50 ± 34 μm and 48 ± 19 μm across different fixation periods. The absolute displacements were 67 ± 31 μm and 81 ± 26 μm. ChBF was negatively correlated with age (R =−0.7, p = 0.003), declining 2.7 ml/100 ml/min per year. There were no significant correlations between ChBF versus perfusion pressure, arterial pressure, or IOP. There were also no significant correlations between age versus perfusion pressure, arterial pressure, or IOP. Multiple regression analysis indicated that age was the only measured independent variable that was significantly correlated with ChBF (p = 0.03). Conclusions The visual fixation protocol with cued eye blinks was effective in achieving sufficient stability for MRI measurements. ChBF had a significant negative correlation with age. PMID:24655028
ERIC Educational Resources Information Center
Crouter, Ann C.; Bumpus, Matthew F.; Maguire, Mary C.; McHale, Susan M.
1999-01-01
Examined connections between parents' work pressure and adolescent adjustment in 190 dual-earner families. Found that effects of work pressure on adolescent well-being were mediated by parental role overload and parent-adolescent conflict. Fathers' work pressure predicted both parents' feelings of role overload. Mothers' work pressure predicted…
Semenistaya, Ekaterina; Zvereva, Irina; Krotov, Grigory; Rodchenkov, Grigory
2016-09-01
Currently liquid chromatography - mass spectrometry (LC-MS) analysis after solid-phase extraction (SPE) on weak cation-exchange cartridges is a method of choice for anti-doping analysis of small bioactive peptides such as growth hormone releasing peptides (GHRPs), desmoporessin, LHRH, and TB-500 short fragment. Dilution of urine samples with phosphate buffer for pH adjustment and SPE on weak cation exchange microelution plates was tested as a means to increase throughput of this analysis. Dilution using 200 mM phosphate buffer provides good buffering capacity without affecting the peptides recoveries. SPE on microelution plates was performed on Waters Positive Pressure-96 Processor with subsequent evaporation of eluates in nitrogen flow. Though the use of smaller sample volume decreases the pre-concentration factor and increases the limits of detection of 5 out of 17 detected peptides, the recovery, linearity, and reproducibility of the microelution extraction were comparable with cartridge SPE. The effectiveness of protocols was confirmed by analysis of urine samples containing ipamorelin, and GHRP-6 and its metabolites. SPE after urine sample dilution with buffer can be used for faster sample preparation. The use of microelution plates decreases consumption of solvents and allows processing of up to 96 samples simultaneously. Cartridge SPE with manual рН adjustment remains the best option for confirmation. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Clark, Christopher E; Taylor, Rod S; Butcher, Isabella; Stewart, Marlene CW; Price, Jackie; Fowkes, F Gerald R; Shore, Angela C; Campbell, John L
2016-01-01
Background Differences in blood pressure between arms are associated with increased cardiovascular mortality in cohorts with established vascular disease or substantially elevated cardiovascular risk. Aim To explore the association of inter-arm difference (IAD) with mortality in a community-dwelling cohort that is free of cardiovascular disease. Design and setting Cohort analysis of a randomised controlled trial in central Scotland, from April 1998 to October 2008. Method Volunteers from Lanarkshire, Glasgow, and Edinburgh, free of pre-existing vascular disease and with an ankle-brachial index ≤0.95, had systolic blood pressure measured in both arms at recruitment. Inter-arm blood pressure differences were calculated and examined for cross-sectional associations and differences in prospective survival. Outcome measures were cardiovascular events and all-cause mortality during mean follow-up of 8.2 years. Results Based on a single pair of measurements, 60% of 3350 participants had a systolic IAD ≥5 mmHg and 38% ≥10 mmHg. An IAD ≥5 mmHg was associated with increased cardiovascular mortality (adjusted hazard ratio [HR] 1.91, 95% confidence interval [CI] = 1.19 to 3.07) and all-cause mortality (adjusted HR 1.44, 95% CI = 1.15 to 1.79). Within the subgroup of 764 participants who had hypertension, IADs of ≥5 mmHg or ≥10 mmHg were associated with both cardiovascular mortality (adjusted HR 2.63, 95% CI = 0.97 to 7.02, and adjusted HR 2.96, 95% CI = 1.27 to 6.88, respectively) and all-cause mortality (adjusted HR 1.67, 95% CI = 1.05 to 2.66, and adjusted HR 1.63, 95% CI = 1.06 to 2.50, respectively). IADs ≥15 mmHg were not associated with survival differences in this population. Conclusion Systolic IADs in blood pressure are associated with increased risk of cardiovascular events, including mortality, in a large cohort of people free of pre-existing vascular disease. PMID:27080315
Clark, Christopher E; Taylor, Rod S; Butcher, Isabella; Stewart, Marlene Cw; Price, Jackie; Fowkes, F Gerald R; Shore, Angela C; Campbell, John L
2016-05-01
Differences in blood pressure between arms are associated with increased cardiovascular mortality in cohorts with established vascular disease or substantially elevated cardiovascular risk. To explore the association of inter-arm difference (IAD) with mortality in a community-dwelling cohort that is free of cardiovascular disease. Cohort analysis of a randomised controlled trial in central Scotland, from April 1998 to October 2008. Volunteers from Lanarkshire, Glasgow, and Edinburgh, free of pre-existing vascular disease and with an ankle-brachial index ≤0.95, had systolic blood pressure measured in both arms at recruitment. Inter-arm blood pressure differences were calculated and examined for cross-sectional associations and differences in prospective survival. Outcome measures were cardiovascular events and all-cause mortality during mean follow-up of 8.2 years. Based on a single pair of measurements, 60% of 3350 participants had a systolic IAD ≥5 mmHg and 38% ≥10 mmHg. An IAD ≥5 mmHg was associated with increased cardiovascular mortality (adjusted hazard ratio [HR] 1.91, 95% confidence interval [CI] = 1.19 to 3.07) and all-cause mortality (adjusted HR 1.44, 95% CI = 1.15 to 1.79). Within the subgroup of 764 participants who had hypertension, IADs of ≥5 mmHg or ≥10 mmHg were associated with both cardiovascular mortality (adjusted HR 2.63, 95% CI = 0.97 to 7.02, and adjusted HR 2.96, 95% CI = 1.27 to 6.88, respectively) and all-cause mortality (adjusted HR 1.67, 95% CI = 1.05 to 2.66, and adjusted HR 1.63, 95% CI = 1.06 to 2.50, respectively). IADs ≥15 mmHg were not associated with survival differences in this population. Systolic IADs in blood pressure are associated with increased risk of cardiovascular events, including mortality, in a large cohort of people free of pre-existing vascular disease. © British Journal of General Practice 2016.
Effects of Structured Versus Usual Care on Renal Endpoint in Type 2 Diabetes: The SURE Study
Chan, Juliana C.; So, Wing-Yee; Yeung, Chun-Yip; Ko, Gary T.; Lau, Ip-Tim; Tsang, Man-Wo; Lau, Kam-Piu; Siu, Sing-Chung; Li, June K.; Yeung, Vincent T.; Leung, Wilson Y.; Tong, Peter C.
2009-01-01
OBJECTIVE Multifaceted care has been shown to reduce mortality and complications in type 2 diabetes. We hypothesized that structured care would reduce renal complications in type 2 diabetes. RESEARCH DESIGN AND METHODS A total of 205 Chinese type 2 diabetic patients from nine public hospitals who had plasma creatinine levels of 150–350 μmol/l were randomly assigned to receive structured care (n = 104) or usual care (n = 101) for 2 years. The structured care group was managed according to a prespecified protocol with the following treatment goals: blood pressure <130/80 mmHg, A1C <7%, LDL cholesterol <2.6 mmol/l, triglyceride <2 mmol/l, and persistent treatment with renin-angiotensin blockers. The primary end point was death and/or renal end point (creatinine >500 μmol/l or dialysis). RESULTS Of these 205 patients (mean ± SD age 65 ± 7.2 years; disease duration 14 ± 7.9 years), the structured care group achieved better control than the usual care group (diastolic blood pressure 68 ± 12 vs. 71 ± 12 mmHg, respectively, P = 0.02; A1C 7.3 ± 1.3 vs. 8.0 ± 1.6%, P < 0.01). After adjustment for age, sex, and study sites, the structured care (23.1%, n = 24) and usual care (23.8%, n = 24; NS) groups had similar end points, but more patients in the structured care group attained ≥3 treatment goals (61%, n = 63, vs. 28%, n = 28; P < 0.001). Patients who attained ≥3 treatment targets (n = 91) had reduced risk of the primary end point (14 vs. 34; relative risk 0.43 [95% CI 0.21–0.86] compared with that of those who attained ≤2 targets (n = 114). CONCLUSIONS Attainment of multiple treatment targets reduced the renal end point and death in type 2 diabetes. In addition to protocol, audits and feedback are needed to improve outcomes. PMID:19460913
Stergiou, G S; Tzamouranis, D; Nasothimiou, E G; Protogerou, A D
2008-11-01
An appropriate cuff according to the individual's arm circumference is recommended with all blood pressure (BP) monitors. An electronic device for home monitoring has been developed (Visomat Comfort 20/40) that estimates the individual's arm circumference by measuring the cuff filing volume and makes an adjustment of measured BP taking into account the estimated arm circumference. Thus the manufacturer recommends the use of a single cuff for arm circumference 23-43 cm. The device accuracy was assessed using the European Society of Hypertension International Protocol. Simultaneous BP measurements were obtained in 33 adults by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements taken using the tested device. Absolute device-observer BP differences were classified into < or =5, < or =10 and < or =15 mm Hg zones. For each participant the number of measurements with a difference < or =5 mm Hg was calculated. The device produced 60/89/97 measurements within 5/10/15 mm Hg respectively for systolic BP, and 72/97/98 for diastolic. Twenty-three subjects had at least two of their systolic BP differences < or =5 mm Hg and three had no differences < or =5 mm Hg (for diastolic 27 and 1, respectively). Mean device-observer BP difference (systolic/diastolic) was 3.7 +/- 5.6/-1.5 +/- 4.7 mm Hg (4.7 +/- 4.9/ - 1.7 +/- 4.3 in arm circumference 23-29 cm [39 readings] and 3.1 +/- 5.9/-1.4 +/- 5.0 in arm 30-34 cm [60 readings], P=NS). In conclusion, the device fulfils the International Protocol requirements and can be recommended for clinical use. Interestingly, the device was accurate using a single cuff in a wide range of arm circumference (23-34 cm). This study provides no information about the device accuracy in larger arms.
Du, Yu-Zheng; Gao, Xin-Xin; Wang, Cheng-Ting; Zheng, Hai-Zhen; Lei, Yun; Wu, Meng-Han; Shi, Xue-Min; Ban, Hai-Peng; Gu, Wen-Long; Meng, Xiang-Gang; Wei, Mao-Ti; Hu, Chun-Xiao
2017-09-15
Stroke is the prime cause of morbidity and mortality in the general population, and hypertension will increase the recurrence and mortality of stroke. We report a protocol of a pragmatic randomized controlled trial (RCT) using blood pressure (BP)-lowering acupuncture add-on treatment to treat patients with hypertension and stroke. This is a large-scale, multicenter, subject-, assessor- and analyst-blinded, pragmatic RCT. A total of 480 patients with hypertension and ischemic stroke will be randomly assigned to two groups: an experimental group and a control group. The experimental group will receive "HuoXueSanFeng" acupuncture combined with one antihypertensive medication in addition to routine ischemic stroke treatment. The control group will only receive one antihypertensive medication and basic treatments for ischemic stroke. HuoXueSanFeng acupuncture will be given for six sessions weekly for the first 6 weeks and three times weekly for the next 6 weeks. A 9-month follow-up will, thereafter, be conducted. Antihypertensive medication will be adjusted based on BP levels. The primary outcome will be the recurrence of stroke. The secondary outcomes including 24-h ambulatory BP, the TCM syndrome score, the Short Form 36-item Health Survey (SF-36), the National Institute of Health Stroke Scale (NIHSS), as well as the Barthel Index (BI) scale will be assessed at baseline, 6 weeks and 12 weeks post initiating treatments; cardiac ultrasound, carotid artery ultrasound, transcranial Doppler, and lower extremity ultrasound will be evaluated at baseline and 12 weeks after treatment. The safety of acupuncture will also be assessed. We aim to determine the clinical effects of controlling BP for secondary prevention of stroke with acupuncture add-on treatment. ClinicalTrials.gov, ID: NCT02967484 . Registered on 13 February 2017; last updated on 27 June 2017.
Chan, Juliana C; So, Wing-Yee; Yeung, Chun-Yip; Ko, Gary T; Lau, Ip-Tim; Tsang, Man-Wo; Lau, Kam-Piu; Siu, Sing-Chung; Li, June K; Yeung, Vincent T; Leung, Wilson Y; Tong, Peter C
2009-06-01
Multifaceted care has been shown to reduce mortality and complications in type 2 diabetes. We hypothesized that structured care would reduce renal complications in type 2 diabetes. A total of 205 Chinese type 2 diabetic patients from nine public hospitals who had plasma creatinine levels of 150-350 micromol/l were randomly assigned to receive structured care (n = 104) or usual care (n = 101) for 2 years. The structured care group was managed according to a prespecified protocol with the following treatment goals: blood pressure <130/80 mmHg, A1C <7%, LDL cholesterol <2.6 mmol/l, triglyceride <2 mmol/l, and persistent treatment with renin-angiotensin blockers. The primary end point was death and/or renal end point (creatinine >500 micromol/l or dialysis). Of these 205 patients (mean +/- SD age 65 +/- 7.2 years; disease duration 14 +/- 7.9 years), the structured care group achieved better control than the usual care group (diastolic blood pressure 68 +/- 12 vs. 71 +/- 12 mmHg, respectively, P = 0.02; A1C 7.3 +/- 1.3 vs. 8.0 +/- 1.6%, P < 0.01). After adjustment for age, sex, and study sites, the structured care (23.1%, n = 24) and usual care (23.8%, n = 24; NS) groups had similar end points, but more patients in the structured care group attained >or=3 treatment goals (61%, n = 63, vs. 28%, n = 28; P < 0.001). Patients who attained >or=3 treatment targets (n = 91) had reduced risk of the primary end point (14 vs. 34; relative risk 0.43 [95% CI 0.21-0.86] compared with that of those who attained
Bocchiardo, M; Alciati, M; Buscemi, A; Cravetto, A; Richiardi, E; Gaita, F
1995-05-01
Carotid sinus massage is a first level test when investigating the cause of syncope. It is normally performed in the supine and erect positions. However, there is no standard complete protocol. So we have devised a new protocol to evaluate the utility of carotid sinus massage in different postures and the influence of patients age on the response. Two groups of subjects were selected: a group of 167 patients (mean age 50 ys +/- 18, 105 males, 62 females) with a history of syncope without cardiovascular and neurological disease and 20 asymptomatic control subjects (mean age 52 ys +/- 13, 11 males, 9 females). Carotid sinus massage was performed supine, just after passive tilt, after 5 minutes of tilt and just after passive return to supine. If a pause > 3" was detected, the protocol was repeated after atropine i.v. injection. Borderline vasodepressor: blood pressure reduction > 30 but < 50 mm Hg without symptoms; vasodepressor: blood pressure reduction > 50 mm Hg or > 30 mm Hg with symptoms like dizziness, vertigo or syncope; cardioinhibitory: pause > 3"; mixed: cardioinhibitory with blood pressure reduction > 30 mm Hg after atropine. Carotid sinus massage gave all informations in the supine position in 14 (12%) patients, after passive tilt in 67 (57%), after 5 minutes of tilt in 30 (26%), and after return to supine in 6 (5%). The responses were: 13 (8%) borderline vasodepressor, 32 (19%) vasodepressor, 2 (1%) cardioinhibitory, 70 (42%) mixed, 50 (30%) negative. Positive responses were more frequent in patients over 45 years (90% versus 43%). In the control group only 3 (15%) positive responses were elicited (2 borderline vasodepressor, and 1 vasodepressor, all in subjects over 45). This protocol for carotid sinus massage evidenced positive responses in 70% of patients with syncope without cardiovascular and neurological disease; cardioinhibitory responses are rare (2%); positive responses are more frequent in patients over 45 years; the protocol specificity was 85%.
Patrick, Kelli; Martin, Tina
2017-09-01
The question of this review is: what is the effectiveness of droxidopa compared to midodrine on standing blood pressure and orthostatic intolerance symptoms in adults with neurogenic orthostatic hypotension?
James, Lauren; Nzelu, Diane; Hay, Anna; Shennan, Andrew; Kametas, Nikos A
2017-04-01
The aim of this study was to evaluate the accuracy of the Omron MIT Elite automated device in pregnant women with an arm circumference of or above 32 cm, using the British Hypertension Society validation protocol. Blood pressure was measured sequentially in 46 women of any gestation requiring the use of a large cuff (arm circumference ≥32 cm) alternating between the mercury sphygmomanometer and the Omron MIT Elite device. The Omron MIT Elite achieved an overall D/D grade with a mean of the device-observer difference being 7.17±6.67 and 9.31±6.59 for systolic and diastolic blood pressure respectively. Interobserver accuracy was 94.6% for systolic and 95% for diastolic readings within 5 mmHg. The Omron MIT Elite overestimates blood pressure and has failed the British Hypertension Society protocol requirements. Therefore, it cannot be recommended for use in pregnant women with an arm circumference of or above 32 cm.
Coagulation changes during lower body negative pressure and blood loss in humans.
van Helmond, Noud; Johnson, Blair D; Curry, Timothy B; Cap, Andrew P; Convertino, Victor A; Joyner, Michael J
2015-11-01
We tested the hypothesis that markers of coagulation activation are greater during lower body negative pressure (LBNP) than those obtained during blood loss (BL). We assessed coagulation using both standard clinical tests and thrombelastography (TEG) in 12 men who performed a LBNP and BL protocol in a randomized order. LBNP consisted of 5-min stages at 0, -15, -30, and -45 mmHg of suction. BL included 5 min at baseline and following three stages of 333 ml of blood removal (up to 1,000 ml total). Arterial blood draws were performed at baseline and after the last stage of each protocol. We found that LBNP to -45 mmHg is a greater central hypovolemic stimulus versus BL; therefore, the coagulation markers were plotted against central venous pressure (CVP) to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Paired t-tests were used to determine whether the slopes of these regression lines fell on similar trajectories for each protocol. Mean regression line slopes for coagulation markers versus CVP fell on similar trajectories during both protocols, except for TEG α° angle (-0.42 ± 0.96 during LBNP vs. -2.41 ± 1.13°/mmHg during BL; P < 0.05). During both LBNP and BL, coagulation was accelerated as evidenced by shortened R-times (LBNP, 9.9 ± 2.4 to 6.2 ± 1.1; BL, 8.7 ± 1.3 to 6.4 ± 0.4 min; both P < 0.05). Our results indicate that LBNP models the general changes in coagulation markers observed during BL. Copyright © 2015 the American Physiological Society.
Simões, Rodrigo Polaquini; Castello-Simões, Viviane; Mendes, Renata Gonçalves; Archiza, Bruno; Dos Santos, Daniel Augusto; Bonjorno, José Carlos; de Oliveira, Claudio Ricardo; Catai, Aparecida Maria; Arena, Ross; Borghi-Silva, Audrey
2014-03-01
The purposes of this study were to determine anaerobic threshold (AT) during discontinuous dynamic and resistive exercise protocols by analysing of heart rate variability (HRV) and blood lactate (BL) in healthy elderly subjects and compare the cardiovascular, metabolic and autonomic variables obtained from these two forms of exercise. Fourteen elderly (70 ± 4 years) apparently healthy males underwent the following tests: (i) incremental ramp test on cycle ergometer, (ii) one repetition maximum (1RM) leg press at 45°, (iii) a discontinuous exercise test on a cycle ergometer (DET-C) protocol and (iv) a resistance exercise leg press (DET-L) protocol. Heart rate, blood pressure and BL were obtained during each increment of exercise intensity. No significant differences (P>0·05) were found between methods of AT determination (BL and HRV) nor the relative intensity corresponding to AT (30% of maximum intensity) between the types of exercise (DET-C and DET-L). Furthermore, no significant differences (P>0·05) were found between the DET-C and DET-L in relation to HRV, however, the DET-L provided higher values of systolic blood pressure and BL (P<0·05) from the intensity corresponding to AT. We conclude that HRV was effective in determination of AT, and the parasympathetic modulation responses obtained during dynamic and resistive exercise protocols were similar when compared at the same relative intensity. However, DET-L resulted in higher values of blood pressure and BL at workloads beyond AT. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Pavela, James; Suresh, Rahul; Blue, Rebecca S; Mathers, Charles H; Belalcazar, L Maria
2018-02-01
Individuals with diabetes are increasingly seeking pretravel advice, but updated professional recommendations remain scant. We performed a systematic review on diabetes management during air travel to summarize current recommendations, assess supporting evidence, and identify areas of future research. A systematic review of the English literature on diabetes management during air travel was undertaken utilizing PubMed and MEDLINE. Publications regarding general travel advice; adjustment of insulin and noninsulin therapies; and the use of insulin pumps, glucometers and subcutaneous glucose sensors at altitude were included. Gathered information was used to create an updated summary of glucose-lowering medication adjustment during air travel. Sixty-one publications were identified, most providing expert opinion and few offering primary data (47 expert opinion, 2 observational studies, 2 case reports, 10 device studies). General travel advice was uniform, with increasing attention to preflight security. Indications for oral antihyperglycemic therapy adjustments varied. There were few recommendations on contemporary agents and on nonhypoglycemic adverse events. There was little consensus on insulin adjustment protocols, many antedating current insulin formulations. Most publications advocated adjusting insulin pump time settings after arrival; however, there was disagreement on timing and rate adjustments. Glucometers and subcutaneous glucose sensors were reported to be less accurate at altitude, but not to an extent that would preclude their clinical use. Recommendations for diabetes management during air travel vary significantly and are mostly based on expert opinion. Data from systematic investigation on glucose-lowering medication adjustment protocols may support the development of a future consensus statement. CSII = continuous subcutaneous insulin infusion (device) DPP-4 = dipeptidyl peptidase 4 EGA = error grid analysis GDH = glucose dehydrogenase GOX = glucose oxidase GLP1 = glucagon-like peptide-1 NPH = neutral protamine Hagedorn SGLT2 = sodium-glucose cotransporter-2.
Moppett, Iain Keith; White, Stuart; Griffiths, Richard; Buggy, Donal
2017-07-25
Hypotension during anaesthesia for hip fracture surgery is common. Recent data suggest that there is an association between the lowest intra-operative blood pressure and mortality, even when adjusted for co-morbidities. This is consistent with data derived from the wider surgical population, where magnitude and duration of hypotension are associated with mortality and peri-operative complications. However, there are no trial to data to support more aggressive blood pressure control. We are conducting a three-centre, randomised, double-blinded pilot study in three hospitals in the United Kingdom. The sample size will be 75 patients (25 from each centre). Randomisation will be done using computer-generated concealed tables. Both participants and investigators will be blinded to group allocation. Participants will be aged >70 years, cognitively intact (Abbreviated Mental Test Score 7 or greater), able to give informed consent and admitted directly through the emergency department with a fractured neck of the femur requiring operative repair. Patients randomised to tight blood pressure control or avoidance of intra-operative hypotension will receive active treatment as required to maintain both of the following: systolic arterial blood pressure >80% of baseline pre-operative value and mean arterial pressure >75 mmHg throughout. All participants will receive standard hospital care, including spinal or general anaesthesia, at the discretion of the clinical team. The primary outcome is a composite of the presence or absence of defined cardiovascular, renal and delirium morbidity within 7 days of surgery (myocardial injury, stroke, acute kidney injury, delirium). Secondary endpoints will include the defined individual morbidities, mortality, early mobility and discharge to usual residence. This is a small-scale pilot study investigating the feasibility of a trial of tight intra-operative blood pressure control in a frail elderly patient group with known high morbidity and mortality. Positive findings will provide the basis for a larger-scale study. ISRCTN Registry identifier: ISRCTN89812075 . Registered on 30 August 2016.
Walther, Paul; Schmid, Eberhard; Höhn, Katharina
2013-01-01
Using an electron microscope's scanning transmission mode (STEM) for collection of tomographic datasets is advantageous compared to bright field transmission electron microscopic (TEM). For image formation, inelastic scattering does not cause chromatic aberration, since in STEM mode no image forming lenses are used after the beam has passed the sample, in contrast to regular TEM. Therefore, thicker samples can be imaged. It has been experimentally demonstrated that STEM is superior to TEM and energy filtered TEM for tomography of samples as thick as 1 μm. Even when using the best electron microscope, adequate sample preparation is the key for interpretable results. We adapted protocols for high-pressure freezing of cultivated cells from a physiological state. In this chapter, we describe optimized high-pressure freezing and freeze substitution protocols for STEM tomography in order to obtain high membrane contrast.
Blood flow dynamics in heart failure
NASA Technical Reports Server (NTRS)
Shoemaker, J. K.; Naylor, H. L.; Hogeman, C. S.; Sinoway, L. I.
1999-01-01
BACKGROUND: Exercise intolerance in heart failure (HF) may be due to inadequate vasodilation, augmented vasoconstriction, and/or altered muscle metabolic responses that lead to fatigue. METHODS AND RESULTS: Vascular and metabolic responses to rhythmic forearm exercise were tested in 9 HF patients and 9 control subjects (CTL) during 2 protocols designed to examine the effect of HF on the time course of oxygen delivery versus uptake (protocol 1) and on vasoconstriction during exercise with 50 mm Hg pressure about the forearm to evoke a metaboreflex (protocol 2). In protocol 1, venous lactate and H+ were greater at 4 minutes of exercise in HF versus CTL (P<0.05) despite similar blood flow and oxygen uptake responses. In protocol 2, mean arterial pressure increased similarly in each group during ischemic exercise. In CTL, forearm blood flow and vascular conductance were similar at the end of ischemic and ambient exercise. In HF, forearm blood flow and vascular conductance were reduced during ischemic exercise compared with the ambient trial. CONCLUSIONS: Intrinsic differences in skeletal muscle metabolism, not vasodilatory dynamics, must account for the augmented glycolytic metabolic responses to moderate-intensity exercise in class II and III HF. The inability to increase forearm vascular conductance during ischemic handgrip exercise, despite a normal pressor response, suggests that enhanced vasoconstriction of strenuously exercising skeletal muscle contributes to exertional fatigue in HF.
Fania, Claudio; Albertini, Federica; Palatini, Paolo
2017-08-01
The aim of this study was to determine the accuracy of the A&D UM-201 device coupled to several cuffs for different arm sizes for office blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Evaluation was carried out in 33 individuals. The mean age of the individuals was 59.3±13.2 years, systolic BP was 145.4±20.6 mmHg (range: 109-186 mmHg), diastolic BP was 87.3±18.0 mmHg (range: 50-124 mmHg), and arm circumference was 30.4±4.2 cm (range: 23-39 cm). The protocol requirements were followed precisely. The UM-201 monitor passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated systolic BP by 3.0±2.1 mmHg and diastolic BP by 2.6±2.0 mmHg. These data show that the A&D UM-201 device coupled to several cuffs for different ranges of arm circumference fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.
Saladini, Francesca; Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo
2013-08-01
The objective of this study was to determine the accuracy of the A&D BP UB-542 wrist device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension (ESH). Device evaluation was carried out in 33 patients. The mean age was 50.9±10.1 years, the mean systolic BP was 141.6±22.8 mmHg (range 92 : 189), the mean diastolic BP was 89.2±11.4 mmHg (range 62 : 120), the mean arm circumference was 28.8±3.2 cm (range 23-35), and the mean wrist circumference was 17.1±1.4 cm (range 14-19.5). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated the systolic BP by 1.8±7.2 mmHg and diastolic BP by 1.6±5.7 mmHg. These data show that the A&D BP UB-542 wrist device met the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.
Islam, Mohammad Rafiqul; Khan, Ismail; Attia, John; Hassan, Sheikh Mohammad Nazmul; McEvoy, Mark; D'Este, Catherine; Azim, Syed; Akhter, Ayesha; Akter, Shahnaz; Shahidullah, Sheikh Mohammad; Milton, Abul Hasnat
2012-12-07
Chronic arsenic exposure and its association with hypertension in adults are inconclusive and this cross-sectional study investigated the association. The study was conducted between January and July 2009 among 1,004 participants from 1,682 eligible women and men aged ≥30 years living in rural Bangladesh who had continuously consumed arsenic-contaminated drinking water for at least 6 months. Hypertension was defined as systolic blood pressure ≥140 mmHg (systolic hypertension) and diastolic blood pressure ≥90 mmHg (diastolic hypertension). Pulse pressure was calculated by deducting diastolic from systolic pressure and considered to be increased when the difference was ≥55 mmHg. The prevalence of hypertension was 6.6% (95% CI: 5.1-8.3%). After adjustment for other factors, no excess risk of hypertension was observed for arsenic exposure >50 μg/L or to that of arsenic exposure as quartiles or as duration. Arsenic concentration as quartiles and >50 μg/L did show a strong relationship with increased pulse pressure (adjusted OR: 3.54, 95% CI: 1.46-8.57), as did arsenic exposure for ≥10 years (adjusted OR: 5.25, 95% CI: 1.41-19.51). Arsenic as quartiles showed a dose response relationship with increased pulse pressure. Our study suggests an association between higher drinking water arsenic or duration and pulse pressure, but not hypertension.
Islam, Mohammad Rafiqul; Khan, Ismail; Attia, John; Hassan, Sheikh Mohammad Nazmul; McEvoy, Mark; D’Este, Catherine; Azim, Syed; Akhter, Ayesha; Akter, Shahnaz; Shahidullah, Sheikh Mohammad; Milton, Abul Hasnat
2012-01-01
Chronic arsenic exposure and its association with hypertension in adults are inconclusive and this cross-sectional study investigated the association. The study was conducted between January and July 2009 among 1,004 participants from 1,682 eligible women and men aged ≥30 years living in rural Bangladesh who had continuously consumed arsenic-contaminated drinking water for at least 6 months. Hypertension was defined as systolic blood pressure ≥140 mmHg (systolic hypertension) and diastolic blood pressure ≥90 mmHg (diastolic hypertension). Pulse pressure was calculated by deducting diastolic from systolic pressure and considered to be increased when the difference was ≥55 mmHg. The prevalence of hypertension was 6.6% (95% CI: 5.1–8.3%). After adjustment for other factors, no excess risk of hypertension was observed for arsenic exposure >50μg/L or to that of arsenic exposure as quartiles or as duration. Arsenic concentration as quartiles and >50 μg/L did show a strong relationship with increased pulse pressure (adjusted OR: 3.54, 95% CI: 1.46–8.57), as did arsenic exposure for ≥10 years (adjusted OR: 5.25, 95% CI: 1.41–19.51). Arsenic as quartiles showed a dose response relationship with increased pulse pressure. Our study suggests an association between higher drinking water arsenic or duration and pulse pressure, but not hypertension. PMID:23222207
Padilha, Gisele de A; Horta, Lucas F B; Moraes, Lillian; Braga, Cassia L; Oliveira, Milena V; Santos, Cíntia L; Ramos, Isalira P; Morales, Marcelo M; Capelozzi, Vera Luiza; Goldenberg, Regina C S; de Abreu, Marcelo Gama; Pelosi, Paolo; Silva, Pedro L; Rocco, Patricia R M
2016-12-01
In patients with emphysema, invasive mechanical ventilation settings should be adjusted to minimize hyperinflation while reducing respiratory effort and providing adequate gas exchange. We evaluated the impact of pressure-controlled ventilation (PCV) and pressure support ventilation (PSV) on pulmonary and diaphragmatic damage, as well as cardiac function, in experimental emphysema. Emphysema was induced by intratracheal instillation of porcine pancreatic elastase in Wistar rats, once weekly for 4 weeks. Control animals received saline under the same protocol. Eight weeks after first instillation, control and emphysema rats were randomly assigned to PCV (n = 6/each) or PSV (n = 6/each) under protective tidal volume (6 ml/kg) for 4 h. Non-ventilated control and emphysema animals (n = 6/group) were used to characterize the model and for molecular biology analysis. Cardiorespiratory function, lung histology, diaphragm ultrastructure alterations, extracellular matrix organization, diaphragmatic proteolysis, and biological markers associated with pulmonary inflammation, alveolar stretch, and epithelial and endothelial cell damage were assessed. Emphysema animals exhibited cardiorespiratory changes that resemble human emphysema, such as increased areas of lung hyperinflation, pulmonary amphiregulin expression, and diaphragmatic injury. In emphysema animals, PSV compared to PCV yielded: no changes in gas exchange; decreased mean transpulmonary pressure (Pmean,L), ratio between inspiratory and total time (Ti/Ttot), lung hyperinflation, and amphiregulin expression in lung; increased ratio of pulmonary artery acceleration time to pulmonary artery ejection time, suggesting reduced right ventricular afterload; and increased ultrastructural damage to the diaphragm. Amphiregulin correlated with Pmean,L (r = 0.99, p < 0.0001) and hyperinflation (r = 0.70, p = 0.043), whereas Ti/Ttot correlated with hyperinflation (r = 0.81, p = 0.002) and Pmean,L (r = 0.60, p = 0.04). In the model of elastase-induced emphysema used herein, PSV reduced lung damage and improved cardiac function when compared to PCV, but worsened diaphragmatic injury.
Erdem, Emre; Aydogdu, Türkan; Akpolat, Tekin
2011-02-01
Standard validation protocols are objective guides for healthcare providers, physicians, and patients. The purpose of this study was to test validation of the Medisana MTP Plus upper arm blood pressure (BP) measuring monitor for self-measurement according to the European Society of Hypertension International Protocol (ESH-IP2) in adults. The Medisana MTP Plus monitor is an automated and oscillometric upper arm device for home BP monitoring. Nine consecutive measurements were made according to the ESH-IP2. Overseen by an independent supervisor, measurements were recorded by two observers blinded from both each other's readings and from the device readings. The Medisana MTP Plus device fulfills the validation criteria of the ESH-IP2 for the general population. The mean (standard deviation) of the difference between the observers and the device measurements was 0.6 mmHg (5.1 mmHg) for systolic and 2.7 mmHg (3.4 mmHg) for diastolic pressures, respectively. As the Medisana MTP Plus device has achieved the required standards, it is recommended for home BP monitoring in an adult population.
NASA Astrophysics Data System (ADS)
He, Xiao-Xiao; Li, Jin-Tao; Jia, Xian-Sheng; Tong, Lu; Wang, Xiao-Xiong; Zhang, Jun; Zheng, Jie; Ning, Xin; Long, Yun-Ze
2017-08-01
A multi-hierarchical porous polyaniline (PANI) composite which could be used in good performance pressure sensor and adjustable sensitivity gas sensor has been fabricated by a facile in situ polymerization. Commercial grade sponge was utilized as a template scaffold to deposit PANI via in situ polymerization. With abundant interconnected pores throughout the whole structure, the sponge provided sufficient surface for the growth of PANI nanobranches. The flexible porous structure helped the composite to show high performance in pressure detection with fast response and favorable recoverability and gas detection with adjustable sensitivity. The sensing mechanism of the PANI/sponge-based flexible sensor has also been discussed. The results indicate that this work provides a feasible approach to fabricate efficient sensors with advantages of low cost, facile preparation, and easy signal collection.
He, Xiao-Xiao; Li, Jin-Tao; Jia, Xian-Sheng; Tong, Lu; Wang, Xiao-Xiong; Zhang, Jun; Zheng, Jie; Ning, Xin; Long, Yun-Ze
2017-12-01
A multi-hierarchical porous polyaniline (PANI) composite which could be used in good performance pressure sensor and adjustable sensitivity gas sensor has been fabricated by a facile in situ polymerization. Commercial grade sponge was utilized as a template scaffold to deposit PANI via in situ polymerization. With abundant interconnected pores throughout the whole structure, the sponge provided sufficient surface for the growth of PANI nanobranches. The flexible porous structure helped the composite to show high performance in pressure detection with fast response and favorable recoverability and gas detection with adjustable sensitivity. The sensing mechanism of the PANI/sponge-based flexible sensor has also been discussed. The results indicate that this work provides a feasible approach to fabricate efficient sensors with advantages of low cost, facile preparation, and easy signal collection.
Gas flow meter and method for measuring gas flow rate
Robertson, Eric P.
2006-08-01
A gas flow rate meter includes an upstream line and two chambers having substantially equal, fixed volumes. An adjustable valve may direct the gas flow through the upstream line to either of the two chambers. A pressure monitoring device may be configured to prompt valve adjustments, directing the gas flow to an alternate chamber each time a pre-set pressure in the upstream line is reached. A method of measuring the gas flow rate measures the time required for the pressure in the upstream line to reach the pre-set pressure. The volume of the chamber and upstream line are known and fixed, thus the time required for the increase in pressure may be used to determine the flow rate of the gas. Another method of measuring the gas flow rate uses two pressure measurements of a fixed volume, taken at different times, to determine the flow rate of the gas.
Special report: Occlusive cuff controller
NASA Technical Reports Server (NTRS)
Baker, J. T.
1975-01-01
A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.
Exercise countermeasure protocol management expert system.
Webster, L; Chen, J G; Flores, L; Tan, S
1993-04-01
Exercise will be used primarily to countermeasure against deconditioning on extended space flight. In this paper we describe the development and evaluation of an expert system for exercise countermeasure protocol management. Currently, the system includes two major subsystems: baseline prescription and prescription adjustment. The baseline prescription subsystem is designed to provide initial exercise prescriptions while prescription adjustment subsystem is designed to modify the initial prescription based on the exercised progress. The system runs under three different environments: PC, SUN workstation, and Symbolic machine. The inference engine, baseline prescription module, prescription adjustment module and explanation module are developed under the Symbolic environment by using the ART (Automated Reasoning Tool) software. The Sun environment handles database management features and interfaces with PC environment to obtain physical and physiological data from exercise units on-board during the flight. Eight subjects' data have been used to evaluate the system performance by comparing the prescription of nine experienced exercise physiologists and the one prescribed by the expert system. The results of the validation test indicated that the performance of the expert system was acceptable.
Exercise countermeasure protocol management expert system
NASA Technical Reports Server (NTRS)
Webster, L.; Chen, J. G.; Flores, L.; Tan, S.
1993-01-01
Exercise will be used primarily to countermeasure against deconditioning on extended space flight. In this paper we describe the development and evaluation of an expert system for exercise countermeasure protocol management. Currently, the system includes two major subsystems: baseline prescription and prescription adjustment. The baseline prescription subsystem is designed to provide initial exercise prescriptions while prescription adjustment subsystem is designed to modify the initial prescription based on the exercised progress. The system runs under three different environments: PC, SUN workstation, and Symbolic machine. The inference engine, baseline prescription module, prescription adjustment module and explanation module are developed under the Symbolic environment by using the ART (Automated Reasoning Tool) software. The Sun environment handles database management features and interfaces with PC environment to obtain physical and physiological data from exercise units on-board during the flight. Eight subjects' data have been used to evaluate the system performance by comparing the prescription of nine experienced exercise physiologists and the one prescribed by the expert system. The results of the validation test indicated that the performance of the expert system was acceptable.
Multi-modal anatomical optical coherence tomography and CT for in vivo dynamic upper airway imaging
NASA Astrophysics Data System (ADS)
Balakrishnan, Santosh; Bu, Ruofei; Price, Hillel; Zdanski, Carlton; Oldenburg, Amy L.
2017-02-01
We describe a novel, multi-modal imaging protocol for validating quantitative dynamic airway imaging performed using anatomical Optical Coherence Tomography (aOCT). The aOCT system consists of a catheter-based aOCT probe that is deployed via a bronchoscope, while a programmable ventilator is used to control airway pressure. This setup is employed on the bed of a Siemens Biograph CT system capable of performing respiratory-gated acquisitions. In this arrangement the position of the aOCT catheter may be visualized with CT to aid in co-registration. Utilizing this setup we investigate multiple respiratory pressure parameters with aOCT, and respiratory-gated CT, on both ex vivo porcine trachea and live, anesthetized pigs. This acquisition protocol has enabled real-time measurement of airway deformation with simultaneous measurement of pressure under physiologically relevant static and dynamic conditions- inspiratory peak or peak positive airway pressures of 10-40 cm H2O, and 20-30 breaths per minute for dynamic studies. We subsequently compare the airway cross sectional areas (CSA) obtained from aOCT and CT, including the change in CSA at different stages of the breathing cycle for dynamic studies, and the CSA at different peak positive airway pressures for static studies. This approach has allowed us to improve our acquisition methodology and to validate aOCT measurements of the dynamic airway for the first time. We believe that this protocol will prove invaluable for aOCT system development and greatly facilitate translation of OCT systems for airway imaging into the clinical setting.
Londra, Laura; Moreau, Caroline; Strobino, Donna; Bhasin, Aarti; Zhao, Yulian
2016-09-01
To evaluate the association between different ovarian hyperstimulation protocols and ectopic pregnancy (EP) in in vitro fertilization (IVF) cycles in fresh autologous embryo transfer cycles in the United States between 2008 and 2011 as reported to the Society of Assisted Reproductive Technology (SART). Historical cohort study. Not applicable. None. None. All autologous cycles that resulted in a clinical pregnancy after a fresh, intrauterine embryo transfer and described characteristics of cycles according to protocol were included: luteal GnRH agonist, GnRH agonist flare, or GnRH antagonist. Multivariate logistic regression was conducted to investigate the association between type of protocol and EP. Among 136,605 clinical pregnancies, 2,645 (1.94%) were EP. Ectopic pregnancy was more frequent with GnRH antagonist (2.4%) cycles than with GnRH agonist flare (2.1%) or luteal GnRH agonist (1.6%) cycles. After adjusting for maternal and treatment characteristics, the GnRH antagonist and the GnRH agonist flare protocols were associated with increased odds of EP (adjusted odds ratio [aOR] 1.52; 95% confidence interval [CI], 1.39-1.65; and aOR 1.25; 95% CI, 1.09-1.44, respectively) compared with luteal GnRH agonist. Analysis of differences in the factors related to EP in luteal GnRH agonist versus GnRH antagonist protocols indicated that diminished ovarian reserve was associated with an increased risk of EP in luteal GnRH agonist but not in GnRH antagonist cycles. The type of protocol used during ovarian hyperstimulation in fresh autologous cycles was associated with EP. This finding suggests a role for extrapituitary GnRH on the tubal and uterine environment during ovarian hyperstimulation treatment for IVF. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Eze, N; Murphy, D; Dhar, V; Rehan, V K
2018-02-01
Though nasal continuous positive airway pressure (NCPAP) is commonly used for non-invasive neonatal respiratory support, the optimal method of weaning NCPAP is not established. In this prospective, two-center randomized control trial we hypothesize that gradually increasing spontaneous breathing time off NCPAP increases successful weaning from NCPAP in infants born <31 weeks gestational age. Infants were randomized to one of the two NCPAP weaning protocols, a sprinting, that is, gradually increasing spontaneous breathing time off CPAP, protocol vs a non-sprinting (weaning pressure down) protocol. Eighty-six infants were enrolled in one of the two study groups. Thirty-one infants (77%) in the sprinting group and 30 (75%) in the non-sprinting group were successfully weaned off NCPAP at the first attempt (P>0.05). It took 1.3 (1 to 1.75) (median (IQR)) attempts and 7 (7 to 7) days to wean NCPAP off in the sprinting group vs 1.3 (1 to 1.75) attempts and 7 (7 to 10) days in the non-sprinting group (P>0.05). Additionally, no differences in the secondary outcomes of bronchopulmonary dysplasia, severe retinopathy of prematurity (⩾stage 3), periventricular leukomalacia and length of stay were noted between the two groups. Weaning NCPAP via sprinting or non-sprinting protocol is comparable, not only for successful weaning but also for the occurrence of common neonatal morbidities that impact the long-term outcome in premature infants (ClinicalTrials.gov number, NCT02819050).
A soundproof pressure chamber.
Kitahara, M; Kodama, A; Ozawa, H; Inoue, S
1994-01-01
For neurotological research we designed a soundproof pressure chamber in which pressure can be adjusted +/- 1000 mmH2O at the rate of less than 100 mmH2O per second. Noise in the chamber can be maintained under 30-35 dB while pressure is kept at a given level.
An Ultra-low-power Medium Access Control Protocol for Body Sensor Network.
Li, Huaming; Tan, Jindong
2005-01-01
In this paper, a medium access control (MAC) protocol designed for Body Sensor Network (BSN-MAC) is proposed. BSN-MAC is an adaptive, feedback-based and IEEE 802.15.4-compatible MAC protocol. Due to the traffic coupling and sensor diversity characteristics of BSNs, common MAC protocols can not satisfy the unique requirements of the biomedical sensors in BSN. BSN-MAC exploits the feedback information from the deployed sensors to form a closed-loop control of the MAC parameters. A control algorithm is proposed to enable the BSN coordinator to adjust parameters of the IEEE 802.15.4 superframe to achieve both energy efficiency and low latency on energy critical nodes. We evaluate the performance of BSN-MAC using energy efficiency as the primary metric.
NASA Astrophysics Data System (ADS)
Yu, Si-Ming; Laromaine, Anna; Roig, Anna
2014-07-01
Superparamagnetic iron oxide nanoparticles (SPIONs) are widely used for biological applications due to their unique properties compared to their bulk counterparts, simplified SPIONs stabilization protocols applicable for a wide spectra of biological media remains a challenging issue. In this work, SPIONs with different surface coatings, tetramethylammonium hydroxide-coated SPIONs (T-SPIONs), and citrate-coated SPIONs (C-SPIONs) were synthesized by a facile, rapid and cost effective microwave-assisted method. C-SPIONs show robust stability in biological media of phosphate buffered saline and Roswell Park Memorial Institute Medium, while destabilize in DMEM. T-SPIONs were found to aggregate rapidly and significantly in all tested media. Then, a modified pH adjusted-BSA adsorption protocol and an addition of excess trisodium citrate dihydrate (Na3Cit) were used to enhance their stability in the media. The BSA adsorption protocol showed great efficiency in stabilizing the dispersed state of both SPIONs in the tested media, while the addition of excess Na3Cit showed limited effect, and it was only applicable for C-SPIONs. The formed BSA layer on SPIONs could be imaged by negative staining TEM, and revealed by Cryo-TEM, FTIR, DLS, and the zeta potential measurements. Results indicated that BSA forms a monolayer of a thickness of about 3 ± 1 nm and BSA interacts with C-SPIONs and T-SPIONs through their coating, rather than by replacing them. This synthetic method and stabilization protocol offer a general methodology to obtain SPIONs with a variety of surfactants, stable in different biological media in few minutes.
A standardised protocol for the validation of banking methodologies for arterial allografts.
Lomas, R J; Dodd, P D F; Rooney, P; Pegg, D E; Hogg, P A; Eagle, M E; Bennett, K E; Clarkson, A; Kearney, J N
2013-09-01
The objective of this study was to design and test a protocol for the validation of banking methodologies for arterial allografts. A series of in vitro biomechanical and biological assessments were derived, and applied to paired fresh and banked femoral arteries. The ultimate tensile stress and strain, suture pullout stress and strain, expansion/rupture under hydrostatic pressure, histological structure and biocompatibility properties of disinfected and cryopreserved femoral arteries were compared to those of fresh controls. No significant differences were detected in any of the test criteria. This validation protocol provides an effective means of testing and validating banking protocols for arterial allografts.
Blood pressure and neuropsychological test performance in healthy postmenopausal women.
Alsumali, Adnan; Mekary, Rania A; Seeger, John; Regestein, Quentin
2016-06-01
To study the association between blood pressure and neuropsychological test performance in healthy postmenopausal women. Data from 88 healthy postmenopausal women aged 46-73 years, who were not experiencing hot flashes, and who had participated in a prior drug trial, were analyzed to find whether baseline blood pressure was associated with impaired performance on neuropsychological testing done at 3 follow-up visits separated by 4 weeks. Factor analysis was used to reduce the dimensions of neuropsychological test performance. Mixed linear modeling was used to evaluate the association between baseline blood pressure and repeatedly measured neuropsychological test performance at follow-up in a complete case analysis (n=53). In a sensitivity analysis (n=88), multiple-imputation using the Markov Chain Monte Carlo method was used to account for missing data (blood pressure results) for some visits. The variables recording neuropsychological test performance were reduced to two main factors (Factor 1=selective attention; Factor 2=complex processing). In the complete case analysis, the association between a 20-mmHg increase in diastolic blood pressure and Factor 1 remained statistically significant after adjusting for potential confounders, before adjusting for systolic blood pressure (slope=0.60; 95%CI=0.04,1.16), and after adjusting for systolic blood pressure (slope=0.76; 95%CI=0.06, 1.47). The positive slopes indicated an increase in the time spent performing a given task (i.e., a decrease in neuropsychological test performance). No other significant associations were found between systolic blood pressure and either factor. The results did not materially change after applying the multiple-imputation method. An increase in diastolic blood pressure was associated with a decrease in neuropsychological test performance among older healthy postmenopausal women experiencing hot flashes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pham, Ba'; Teague, Laura; Mahoney, James; Goodman, Laurie; Paulden, Mike; Poss, Jeff; Li, Jianli; Ieraci, Luciano; Carcone, Steven; Krahn, Murray
2011-11-01
Every year, approximately 6.2 million hospital admissions through emergency departments (ED) involve elderly patients who are at risk of developing pressure ulcers. We evaluated the cost-effectiveness of pressure-redistribution foam mattresses on ED stretchers and beds for early prevention of pressure ulcers in elderly admitted ED patients. Using a Markov model, we evaluated the incremental effectiveness (quality-adjusted life-days) and incremental cost (hospital and home care costs) between early prevention and current practice (with standard hospital mattresses) from a health care payer perspective during a 1-year time horizon. The projected incidence of ED-acquired pressure ulcers was 1.90% with current practice and 1.48% with early prevention, corresponding to a number needed to treat of 238 patients. The average upgrading cost from standard to pressure-redistribution mattresses was $0.30 per patient. Compared with current practice, early prevention was more effective, with 0.0015 quality-adjusted life-days gained, and less costly, with a mean cost saving of $32 per patient. If decisionmakers are willing to pay $50,000 per quality-adjusted life-year gained, early prevention was cost-effective even for short ED stay (ie, 1 hour), low hospital-acquired pressure ulcer risk (1% prevalence), and high unit price of pressure-redistribution mattresses ($3,775). Taking input uncertainty into account, early prevention was 81% likely to be cost-effective. Expected value-of-information estimates supported additional randomized controlled trials of pressure-redistribution mattresses to eliminate the remaining decision uncertainty. The economic evidence supports early prevention with pressure-redistribution foam mattresses in the ED. Early prevention is likely to improve health for elderly patients and save hospital costs. Copyright © 2011 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Effect of test exercises and mask donning on measured respirator fit.
Crutchfield, C D; Fairbank, E O; Greenstein, S L
1999-12-01
Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.
Evaluation of Plastic Media Blasting Equipment
1987-04-01
the differential pressure across the filter element or by a timer with a differential pressure switch override. The timer and the differential pressure ...automatic. The mechanism should be activated by the differential pressure across the filter element or by a timer with a differential pressure switch override...The timer and the differential pressure switch settings should be adjustable. The dust then falls to the bottom of the baghouse for
1975-01-29
will shut down automatically when condenser high pressure causes Pressure Limit Control high pressure switch to release. Press START switch (3...power cable (1) from facility pow- er. Troubleshoot cooling unit, for HI-LOW pressure switch repeated cutout. Refer to AGE ECU Cooling Unit...acti- vate when loss of air flow oc- curred, the pressure switch (3) failed to open circuit. Adjust or replace pressure switch . Refer to
NASA Technical Reports Server (NTRS)
Rackl, Robert; Weston, Adam
2005-01-01
The literature on turbulent boundary layer pressure fluctuations provides several empirical models which were compared to the measured TU-144 data. The Efimtsov model showed the best agreement. Adjustments were made to improve its agreement further, consisting of the addition of a broad band peak in the mid frequencies, and a minor modification to the high frequency rolloff. The adjusted Efimtsov predicted and measured results are compared for both subsonic and supersonic flight conditions. Measurements in the forward and middle portions of the fuselage have better agreement with the model than those from the aft portion. For High Speed Civil Transport supersonic cruise, interior levels predicted by use of this model are expected to increase by 1-3 dB due to the adjustments to the Efimtsov model. The space-time cross-correlations and cross-spectra of the fluctuating surface pressure were also investigated. This analysis is an important ingredient in structural acoustic models of aircraft interior noise. Once again the measured data were compared to the predicted levels from the Efimtsov model.
Kvitvang, Hans F N; Bruheim, Per
2015-08-15
Capillary ion chromatography (capIC) is the premium separation technology for low molecular phosphometabolites and nucleotides in biological extracts. Removal of excessive amounts of salt during sample preparation stages is a prerequisite to enable high quality capIC separation in combination with reproducible and sensitive MS detection. Existing sampling protocols for mammalian cells used for GC-MS and LC-MS metabolic profiling can therefore not be directly applied to capIC separations. Here, the development of a fast filtration sampling protocol for mammalian suspension cells tailored for quantitative profiling of the phosphometabolome on capIC-MS/MS is presented. The whole procedure from sampling the culture to transfer of filter to quenching and extraction solution takes less than 10s. To prevent leakage it is critical that a low vacuum pressure is applied, and satisfactorily reproducibility was only obtained by usage of a vacuum pressure controlling device. A vacuum of 60mbar was optimal for filtration of multiple myeloma Jjn-3 cell cultures through 5μm polyvinylidene (PVDF) filters. A quick deionized water (DI-water) rinse step prior to extraction was tested, and significantly higher metabolite yields were obtained during capIC-MS/MS analyses in this extract compared to extracts prepared by saline and reduced saline (25%) washing steps only. In addition, chromatographic performance was dramatically improved. Thus, it was verified that a quick DI-water rinse is tolerated by the cells and can be included as the final stage during filtration. Over 30 metabolites were quantitated in JJN-3 cell extracts by using the optimized sampling protocol with subsequent capIC-MS/MS analysis, and up to 2 million cells can be used in a single filtration step for the chosen filter and vacuum pressure. The technical set-up is also highly advantageous for microbial metabolome filtration protocols after optimization of vacuum pressure and washing solutions, and the reduced salt content of the extract will also improve the quality of LC-MS analysis due to lower salt adduct ion formation. Copyright © 2015 Elsevier B.V. All rights reserved.
The effects of a dynamic tuberal support on ischial buttock load and pattern of blood supply.
van Geffen, Paul; Reenalda, Jasper; Veltink, Peter H; Koopman, Bart F J M
2010-02-01
Sitting acquired pressure ulcers are places of tissue breakdown that mainly occur under the ischial tuberosities (ITs). Successive durations of pressure relief help the buttock tissue recover from sustained deformation and blood-flow stagnation. A computer-aided simulator chair was developed with two adjustable tuberal support elements (TSE) integrated in a force-sensing seating plane (FSP). This study investigated the redistribution of external buttock load in relation to the pattern (i.e., dynamics) of subtuberal blood supply in sitting with a dynamic tuberal support of 1/60 Hz (80 mm/min). Fifteen healthy male subjects were seated with their ITs on the TSE. The experiment involved periodic TSE adjustment in which buttock interface pressure was measured with the FSP and an external pressure mapping device (PMD). Light-guide tissue spectrophotometry was used for simultaneous noninvasive measurement of oxygenation and perfusion in the skin ( < 2 mm) and subcutaneous ( < 8 mm) tissue under the ITs. TSE adjustment seemed effective to regulate centre of buttock pressure and the forces under the ITs. Differences in measurement with the FSP and PMD have been found due to Hammocking at the seat interface and inaccurate peak pressure readings. Subtuberal blood supply was inversely related to the contact load under the ITs. A rapid inflow of blood in the initial stage of tuberal unloading, followed by a gradual outflow in the rest of the movement cycle indicates that the average blood supply increases when the adjustment frequency increases. Future studies must address the influence of a dynamic tuberal support on the ischial buttock load and pattern of blood supply in impaired individuals.
Angiotensin-(1-7)/Mas axis modulates fear memory and extinction in mice.
Lazaroni, Thiago Luiz do Nascimento; Bastos, Cristiane Perácio; Moraes, Márcio Flávio Dutra; Santos, Robson Souza; Pereira, Grace Schenatto
2016-01-01
Inappropriate defense-alerting reaction to fear is a common feature of neuropsychiatric diseases. Therefore, impairments in brain circuits, as well as in molecular pathways underlying the neurovegetative adjustments to fear may play an essential role on developing neuropsychiatric disorders. Here we tested the hypothesis that interfering with angiotensin-(1-7) [Ang-(1-7)]/Mas receptor axis homeostasis, which appears to be essential to arterial pressure control, would affect fear memory and extinction. Mas knockout (MasKO) mice, in FVB/N background, showed normal cued fear memory and extinction, but increased freezing in response to context. Next, as FVB/N has poor performance in contextual fear memory, we tested MasKO in mixed 129xC57BL/6 background. MasKO mice behaved similarly to wild-type (WT), but memory extinction was slower in contextual fear conditioning to a weak protocol (1CS/US). In addition, delayed extinction in MasKO mice was even more pronounced after a stronger protocol (3CS/US). We showed previously that Angiotensin II receptor AT1 antagonist, losantan, rescued object recognition memory deficit in MasKO mice. Here, losartan was also effective. Memory extinction was accelerated in MasKO mice after treatment with losartan. In conclusion, we showed for the first time that Ang-(1-7)/Mas axis may modulate fear memory extinction. Furthermore, we suggest MasKO mice as an animal model to study post-traumatic stress disorder (PTSD). Copyright © 2015 Elsevier Inc. All rights reserved.
2011-01-01
We describe difficult weaning after prolonged mechanical ventilation in three tracheostomized children affected by respiratory virus infection. Although the spontaneous breathing trials were successful, the patients failed all extubations. Therefore a tracheostomy was performed and the weaning plan was begun. The strategy for weaning was the decrease of ventilation support combining pressure control ventilation (PCV) with increasing periods of continuous positive airway pressure + pressure support ventilation (CPAP + PSV) and then CPAP + PSV with increasing intervals of T-piece. They presented acute respiratory distress syndrome on admission with high requirements of mechanical ventilation (MV). Intervening factors in the capabilities and loads of the respiratory system were considered and optimized. The average MV time was 69 days and weaning time 31 days. We report satisfactory results within the context of a directed weaning protocol. PMID:21244710
Protocolized fluid therapy in brain-dead donors: The multi-center randomized MOnIToR trial
Al-Khafaji, Ali; Elder, Michele; Lebovitz, Daniel J; Murugan, Raghavan; Souter, Michael; Stuart, Susan; Wahed, Abdus S.; Keebler, Ben; Dils, Dorrie; Mitchell, Stephanie; Shutterly, Kurt; Wilkerson, Dawn; Pearse, Rupert; Kellum, John A
2015-01-01
BACKGROUND Critical shortages of organs for transplantation jeopardize many lives. Observational data suggest that better fluid management for deceased organ donors could increase organ recovery. We conducted the first large multi-center randomized trial in brain-dead donors to determine whether protocolized fluid therapy increases organs transplanted. METHODS We randomly assigned donors to either protocolized or usual care in eight organ procurement organizations. A “protocol-guided fluid therapy” algorithm targeting cardiac index, mean arterial pressure and pulse pressure variation was used. Our primary outcome was the number of organs transplanted per donor and our primary analysis was intention-to-treat. Secondary analyses included: 1) modified intention-to-treat where only subjects able to receive the intervention were included, and 2) twelve-month survival in transplant recipients. The study was stopped early. RESULTS We enrolled 556 donors; 279 protocolized care, 277 usual care. Groups had similar characteristics at baseline. The study protocol could be implemented in 76% of subjects randomized to the intervention. There was no significant difference in mean number of organs transplanted per donor: 3.39 organs per donor, (95%CI: 3.14-3.63) with protocolized care, compared to usual care 3.29 (95%CI: 3.04-3.54) (mean difference, 0.1, 95%CI: -0.25 to 0.45; p=0.56). In modified intention-to-treat analysis the mean number of organs increased (3.52 organs per donor, 95%CI: 3.23-3.8) but was not statistically significant (mean difference, 0.23, 95%CI: -0.15-0.61; p=0.23). Among the 1430 recipients of organs from study subjects, with data available, 56 deaths (7.8%) occurred in the protocolized care arm and 56 (7.9%) in the usual care arm in the first year (Hazard Ratio: 0.97, p=0.86). CONCLUSIONS In brain-dead organ donors, protocol-guided fluid therapy compared to usual care may not increase the number of organs transplanted per donor. PMID:25583616
Sakka, Laurent; Chomicki, Alexandre; Gabrillargues, Jean; Khalil, Toufic; Chazal, Jean; Avan, Paul
2016-02-01
Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21-87 years (mean age 64.3 years), and the range of the follow-up period was 1-3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3-6 months, 7-15 months, 16-24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors' diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.
Direct Measurement of Intracellular Pressure
Petrie, Ryan J.; Koo, Hyun
2014-01-01
A method to directly measure the intracellular pressure of adherent, migrating cells is described in the Basic Protocol. This approach is based on the servo-null method where a microelectrode is introduced into the cell to directly measure the physical pressure of the cytoplasm. We also describe the initial calibration of the microelectrode as well as the application of the method to cells migrating inside three-dimensional (3D) extracellular matrix (ECM). PMID:24894836
Takahashi, Hakuo; Yoshika, Masamichi; Yokoi, Toyohiko
2013-01-01
Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. This study aimed to evaluate the performance of the wrist-type blood pressure monitors Omron RS8 (HEM-6310F-E), Omron RS6 (HEM-6221-E), and Omron RS3 (HEM-6130-E). A team of three trained doctors validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. All the devices met the validation requirements of the European Society of Hypertension International Protocol revision 2010. The difference in blood pressure readings between the tested device and the standard mercury sphygmomanometer was within 3 mmHg, which is acceptable according to the European Society of Hypertension guidelines. All the home devices tested were found to be suitable for measuring blood pressure at home because their performance fulfilled the requirement of the guidelines.
Schujmann, Debora Stripari; Lunardi, Adriana Claudia; Fu, Carolina
2018-05-10
Enhanced mobility in the Intensive Care Unit (ICU) could minimize the negative effects of critical illness, such as declines in cognitive, muscular, respiratory, and functional capacity. We aim to compare the functional status at ICU discharge of patients who underwent a progressive mobilization protocol versus patients who received conventional physiotherapy. We also examine the level of physical activity in the ICU, the degree of pulmonary and muscle function, and the length of stay to analyze correlations between these variables. This is a protocol for a randomized controlled trial with blind evaluation. Ninety-six ICU patients will be recruited from a single center and randomly assigned to a control group or an intervention group. To determine the level of protocol activity the patient will receive, the patients' ability to participate actively and their muscle strength will be considered. The protocol consists of five phases, ranging from passive therapies to walking and climbing stairs. The primary outcome will be the functional status at ICU discharge, measured with the Barthel Index and the ICU Mobility Scale (IMS). Measured secondary outcomes will include the level of physical activity, maximal inspiratory and expiratory pressures, forced expiratory volume in 1 second, maximum voluntary ventilation, handgrip strength, surface electromyography of the lower limb muscles, and results of the Timed Up and Go and 2-Minute Walk tests. Evaluations will be made within 2 days of ICU discharge except for the level of activity, which will be evaluated daily. Physiological variables and activity level will be analyzed by chi-square and t tests, according to the intention-to-treat paradigm. Mobility and exercise in the ICU should be undertaken with intensity, quantity, duration, and frequency adjusted according to the patients' status. The results of this study may contribute to new knowledge of early mobility in the ICU, activity level, and varying benefits in critical patients, directing new approaches to physiotherapeutic interventions in these patients. Recruitment will begin in February 2017, and the expected completion date is August 2018. Patients are already being recruited. ClinicalTrials.gov, ID: NCT02889146 . Registered on 3 March 2016.
Tong, Tammy YN; Key, Timothy J; Sobiecki, Jakub G; Bradbury, Kathryn E
2018-01-01
ABSTRACT Background A detailed description of anthropometric and physiologic characteristics of persons in different diet groups is lacking. Objective We aimed to perform cross-sectional analyses of diet group with anthropometric and physiologic characteristics in a large cohort in the United Kingdom. Design The UK Biobank recruited ∼500,000 middle-aged participants throughout the United Kingdom in 2006–2010. Anthropometric indexes (height, weight, waist and hip circumference, body composition) and other physiologic characteristics (heel bone mineral density, grip strength, blood pressure, pulse rate) were measured following standardized protocols. We estimated the age-adjusted means of each characteristic in 6 diet groups (198,166 regular meat eaters, 199,784 low meat eaters, 4381 poultry eaters, 9674 fish eaters, 6366 vegetarians, and 378 vegans) in white women and men, and in 2 diet groups (3322 meat eaters and 1186 vegetarians) in British Indian women and men. Results In white women, after adjustment for age and compared with regular meat eaters, non–red meat eaters had lower adiposity (e.g., 4.5% lower body fat in vegan women) and lower systolic and diastolic blood pressure (−4.2 and −3.3 mm Hg, respectively), and generally lower heel bone mineral density t-score (−0.26). Patterns of differences by diet group were similar in white men. In the Indian population, compared with meat eaters, vegetarian women were shorter (−1.1 cm) and had lower lean mass (−0.5 kg), and both vegetarian women and men had lower grip strength (−1.3 and −1.4 kg, respectively). No significant differences in the other characteristics were observed. Conclusions Differences in anthropometric and physiologic characteristics were observed across diet groups in white participants, but fewer differences were observed in British Indian participants. The observed differences may be important as intermediate markers of long-term health in different diet groups. This observational study was registered at http://www.isrctn.com/ as ISRCTN10125697. PMID:29868910
Castetbon, Katia; Grange, Dorothée; Guibert, Gaëlle; Vernay, Michel; Escalon, Hélène; Vincelet, Catherine
2016-08-12
In 2004-2005, a survey carried out on food recipients in France revealed an alarming nutritional situation. In 2011-2012, and using a protocol similar to that of 2004-2005, our objective was to update the description of sociodemographic characteristics, dietary behaviors and clinical parameters of food assistance recipients and to analyze changes since 2004-2005. Both surveys included multistage random sampling of adults benefitting from structures that supply food pantries and charitable grocery stores. Data on sociodemographic characteristics and dietary behaviors were collected along with weight, height and blood pressure measurements. Comparisons between the 2004-2005 (n = 883) and 2011-2012 (n = 1,058) survey observations were made, adjusting for socio-demographic changes which had occurred in the meantime. Since 2004-2005, proportions of food recipients ≥55 years (13.1-19.1 %), born in France (29.2-36.8 %) and employed (5.5-11.7 %) have increased; food insufficiency has decreased (95-74 %). For over half of the recipients, canned (52.4 %) and non-perishable (50.9 %) foods were obtained only from food assistance. Frequency of consumption significantly increased even after adjustment for socio-demographic changes; this was the case for dairy products (for twice a day consumption, 30.2-36.4 %), fruits and vegetables (three times a day, 7.8-13.9 %), and meat, eggs and fish (twice a day, 9.4-19.2 %). In 2011-2012, 15.6 % of men and 36.0 % of women were obese, while 44.5 and 35.1 % had high blood pressure, respectively. Between 2004-2005 and 2011-2012 in France, consumption of staple foods has been slightly improved in food assistance recipients. However, prevalence of cardiovascular risk factors remains high, which underlines the need for long-term efforts at better quality of foods delivered.
Elias, Merrill F; Sullivan, Lisa M; Elias, Penelope K; D'Agostino, Ralph B; Wolf, Philip A; Seshadri, Sudha; Au, Rhoda; Benjamin, Emelia J; Vasan, Ramachandran S
2007-03-01
The purpose of this study was to determine whether echocardiographic left ventricular mass is related to cognitive performance beyond casual blood pressure adjusting for the influence of other vascular risk factors. We used multivariable regression analyses to relate left ventricular mass assessed at a routine examination (1995-1998) to measures of cognitive ability obtained routinely (1998-2001) in 1673 Framingham Offspring Study participants (56% women; mean age: 57 years) free from stroke, transient ischemic attack, and dementia. We adjusted for the following covariates hierarchically: (1) age, education, sex, body weight, height, interval between left ventricular mass measurement and neuropsychological testing (basic model); (2) basic model+blood pressure+treatment for hypertension; and (3) basic model+blood pressure+treatment for hypertension+vascular risk factors and prevalent cardiovascular disease. For the basic model, left ventricular mass was inversely associated with abstract reasoning (similarities), visual-spatial memory and organization, and verbal memory. For the basic model+blood pressure+treatment for hypertension, left ventricular mass was inversely associated with similarities and visual-spatial memory and organization. For the basic+blood pressure+treatment for hypertension+risk factors+cardiovascular disease model, no significant associations were observed. Echocardiographic left ventricular mass is associated with cognitive performance beyond casual and time-averaged systolic blood pressure, but this association is attenuated and rendered nonsignificant with additional adjustment for cardiovascular risk factors and cardiovascular disease, thus suggesting that these variables play an important role in mediating the association between left ventricular mass and cognition.
Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin
2018-03-01
: In the last 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and the International Organization for Standardization (ISO) have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers and manufacturers would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by AAMI, ESH and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols.
Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin
2018-03-01
In the past 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers, and manufacturers, would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by the AAMI, ESH, and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH, and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols. © 2018 American Heart Association, Inc., and Wolters Kluwer Health, Inc.
Grover-Páez, Fernando; Cardona-Muñoz, Ernesto G; Cardona-Müller, David; Guzmán-Saldívar, Víctor H; Rodríguez-De la Cerda, Mariana; Jiménez-Cázarez, Mayra B; Totsuka-Sutto, Sylvia E; Alanis-Sánchez, Guillermo A; Ramos-Becerra, Carlos G
2017-12-01
The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.
Yi, Jun; Wan, Yi; Pan, Feng; Yu, Xiaorong; Zhao, Huadong; Shang, Fujun; Xu, Yongyong
2011-08-01
The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. A total of 99 couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The device produced 73, 93, and 98 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 79, 93, and 96 for diastolic blood pressure (DBP), respectively. The mean standard deviation device-observer difference was 1.4 ± 5.2 mmHg for SBP and 0.02±5.8 mmHg for DBP. The number of participants with two or three of the device-observer differences within 5 mmHg was 24 for SBP and 30 for DBP, whereas there was no participant with none of the device-observer differences within 5 mmHg. According to the results of the validation study based on the ESH-IP revision 2010, the Medipro MediCare 100f can be recommended for self-measurement in an adult population.
Wang, Qing; Zhao, Huadong; Chen, Wan; Li, Ni; Wan, Yi
2014-02-01
The aim of this study was to validate the iHealth BP7 wireless wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained for validation. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. The device produced 66, 87, and 97 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 72, 93, and 99 mmHg for diastolic blood pressure (DBP), respectively. The mean±SD device-observer difference was -0.7±6.9 mmHg for SBP and -1.0±5.1 mmHg for DBP. The number of participants with two or three device-observer differences within 5 mmHg was 25 for SBP and 26 for DBP; furthermore, there were three participants for SBP and one participant for DBP, with none of the device-observer differences within 5 mmHg. On the basis of the validation results, the iHealth BP7 wireless wrist blood pressure monitor can be recommended for self-measurement in an adult population.
Age, arterial stiffness, and components of blood pressure in Chinese adults.
Zheng, Meili; Xu, Xiping; Wang, Xiaobin; Huo, Yong; Xu, Xin; Qin, Xianhui; Tang, Genfu; Xing, Houxun; Fan, Fangfang; Cui, Wei; Yang, Xinchun
2014-12-01
Blood pressure (BP) changes with age. We conducted a cross-sectional study in rural Chinese adults to investigate: (1) what is the relationship between age, arterial stiffness, and BP in Chinese men and women; and (2) to what degree can the age-BP relationship be explained by arterial stiffness, controlling for other covariables. These analyses included a total of 1688 subjects (males/females: 623/1065), aged 40 to 88 years. Among them, 353 (20.9%) had hypertension (defined as systolic blood pressure (SBP) ≥ 140 mm Hg or diastolic blood pressure (DBP) ≥ 90 mm Hg). Arterial stiffness was measured by brachial-ankle pulse wave velocity (baPWV). baPWV appeared to be more strongly correlated with BP (including SBP, DBP, mean arterial pressure [MAP], pulse pressure [PP]) than age (P < 0.001 for comparisons between Spearman correlation coefficients). Furthermore, baPWV was associated with BP (including SBP, DBP, MAP, and PP) and risk of hypertension in a dose-response fashion, independent of age; in contrast, the age-BP associations were either attenuated or became negative after adjusting for baPWV. Arterial stiffness appears to be an independent contributor to hypertension, even after adjusting for age and other covariables. In contrast, age-BP associations became attenuated or negative after adjusting for baPWV. The utility of baPWV as a diagnostic, prognostic, and therapeutic indicator for hypertension warrants further investigation.
Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang
2005-01-01
To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.
Management of Gastric Obstruction Caused by Adjustable Gastric Band.
Czeiger, David; Abu-Swis, Shadi; Shaked, Gad; Ovnat, Amnon; Sebbag, Gilbert
2016-12-01
Optimal adjustment of the filling volume of laparoscopic adjustable gastric banding is challenging and commonly performed empirically. Patients with band over-inflation and gastric obstruction arrive at the emergency department complaining of recurrent vomiting. In cases of gastric obstruction, intra-band pressure measurement may assist in determining the amount of fluid that should be removed from the band; however, our investigations have determined that intra-band pressure assessment need not play a role in the treatment of gastric band obstruction. In patients coming to the emergency department with gastric band obstruction, we measured intra-band pressure at arrival and following stepped removal of fluid, comparing the initial pressure with post-deflation pressure and measuring the volume of fluid removed. Forty-eight patients participated in the study. Forty-five patients had a low-pressure/high-volume band. Their mean baseline pressure was 54.6 ± 22.3 mmHg. The mean volume of fluid removed from the band was 1.3 ± 0.8 ml. The mean post-deflation pressure was 22.5 ± 16.3 mmHg. Nearly 30 % of patients required as little as 0.5 ml of fluid removal, and 60 % of them were free of symptoms with removal of 1 ml. Our results indicate that intra-band pressure measurement is of little value for determining the amount of fluid that should be removed for treatment of band obstruction. We suggest the removal of fluid in volumes of 0.5 ml until symptoms are relieved. Only in complicated cases, such as in patients having recurrent obstructions, should additional modalities be employed for further management guidance.
Levine, David Michael; Dixon, Ronald F; Linder, Jeffrey A
2018-04-23
Optimal management of hypertension requires frequent monitoring and follow-up. Novel, pragmatic interventions have the potential to engage patients, maintain blood pressure control, and enhance access to busy primary care practices. "Virtual visits" are structured asynchronous online interactions between a patient and a clinician to extend medical care beyond the initial office visit. To compare blood pressure control and healthcare utilization between patients who received virtual visits compared to usual hypertension care. Propensity score-matched, retrospective cohort study with adjustment by difference-in-differences. Primary care patients with hypertension. Patient participation in at least one virtual visit for hypertension. Usual care patients did not use a virtual visit but were seen in-person for hypertension. Adjusted difference in mean systolic blood pressure, primary care office visits, specialist office visits, emergency department visits, and inpatient admissions in the 180 days before and 180 days after the in-person visit. Of the 1051 virtual visit patients and 24,848 usual care patients, we propensity score-matched 893 patients from each group. Both groups were approximately 61 years old, 44% female, 85% White, had about five chronic conditions, and about 20% had a mean pre-visit systolic blood pressure of 140-160 mmHg. Compared to usual care, virtual visit patients had an adjusted 0.8 (95% CI, 0.3 to 1.2) fewer primary care office visits. There was no significant adjusted difference in systolic blood pressure control (0.6 mmHg [95% CI, - 2.0 to 3.1]), specialist visits (0.0 more visits [95% CI, - 0.3 to 0.3]), emergency department visits (0.0 more visits [95% CI, 0.0 to 0.01]), or inpatient admissions (0.0 more admissions [95% CI, 0.0 to 0.1]). Among patients with reasonably well-controlled hypertension, virtual visit participation was associated with equivalent blood pressure control and reduced in-office primary care utilization.
On-farm comparisons of different cleaning protocols in broiler houses.
Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K
2015-08-01
The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.
López-de-Uralde-Villanueva, Ibai; Candelas-Fernández, Pablo; de-Diego-Cano, Beatriz; Mínguez-Calzada, Orcález; Del Corral, Tamara
2018-06-01
The objective of this study was to evaluate whether the addition of manual therapy and therapeutic exercise protocol to inspiratory muscle training was more effective in improving maximum inspiratory pressure than inspiratory muscle training in isolation. This is a single-blinded, randomized controlled trial. In total, 43 patients with asthma were included in this study. The patients were allocated into one of the two groups: (1) inspiratory muscle training ( n = 21; 20-minute session) or (2) inspiratory muscle training (20-minute session) combined with a program of manual therapy (15-minute session) and therapeutic exercise (15-minute session; n = 22). All participants received 12 sessions, two days/week, for six weeks and performed the domiciliary exercises protocol. The main measures such as maximum inspiratory pressure, spirometric measures, forward head posture, and thoracic kyphosis were recorded at baseline and after the treatment. For the per-protocol analysis, between-group differences at post-intervention were observed in maximum inspiratory pressure (19.77 cmH 2 O (11.49-28.04), P < .05; F = 22.436; P < .001; η 2 p = 0.371) and forward head posture (-1.25 cm (-2.32 to -0.19), P < .05; F = 5.662; P = .022; η 2 p = 0.13). The intention-to-treat analysis showed the same pattern of findings. The inspiratory muscle training combined with a manual therapy and therapeutic exercise program is more effective than its application in isolation for producing short-term maximum inspiratory pressure and forward head posture improvements in patients with asthma.
W-MAC: A Workload-Aware MAC Protocol for Heterogeneous Convergecast in Wireless Sensor Networks
Xia, Ming; Dong, Yabo; Lu, Dongming
2011-01-01
The power consumption and latency of existing MAC protocols for wireless sensor networks (WSNs) are high in heterogeneous convergecast, where each sensor node generates different amounts of data in one convergecast operation. To solve this problem, we present W-MAC, a workload-aware MAC protocol for heterogeneous convergecast in WSNs. A subtree-based iterative cascading scheduling mechanism and a workload-aware time slice allocation mechanism are proposed to minimize the power consumption of nodes, while offering a low data latency. In addition, an efficient schedule adjustment mechanism is provided for adapting to data traffic variation and network topology change. Analytical and simulation results show that the proposed protocol provides a significant energy saving and latency reduction in heterogeneous convergecast, and can effectively support data aggregation to further improve the performance. PMID:22163753
UV Impacts Avoided by the Montreal Protocol
NASA Technical Reports Server (NTRS)
Newman, Paul; McKenzie, Richard
2010-01-01
Temporal and geographical variabilities in the future "World Expected" UV environment are compared with the "World Avoided", which would have occurred without the Montreal Protocol on protection of the ozone layer and its subsequent amendments and adjustments. Based on calculations of clear-sky UV irradiances, the effects of the Montreal Protocol have been hugely beneficial to avoid the health risks, such as skin cancer, which are associated with high UV, while there is only a small increase in health risks, such as vitamin D deficiency, that are associated with low UV. However, interactions with climate change may lead to changes in cloud and albedo, and possibly behavioural changes which could also be important.
UV impacts avoided by the Montreal Protocol.
Newman, Paul A; McKenzie, Richard
2011-07-01
Temporal and geographical variabilities in the future "world expected" UV environment are compared with the "world avoided", which would have occurred without the Montreal Protocol on Substances That Deplete the Ozone Layer and its subsequent amendments and adjustments. Based on calculations of clear-sky UV irradiances, the effects of the Montreal Protocol have been hugely beneficial to avoid the health risks, such as skin cancer, which are associated with high UV, while there is only a small increase in health risks, such as vitamin D deficiency, that are associated with low UV. However, interactions with climate change may lead to changes in cloud and albedo, and possibly behavioural changes that could also be important.
Peterson, David A.; Zumberge, Jeremy R.
2006-01-01
Samples of benthic macroinvertebrates were collected side-by-side from riffles at 12 stream sites in Wyoming, Colorado, and Montana during 2000-2001, following protocols established by the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program and the U.S. Environmental Protection Agency Environmental Monitoring and Assessment Program (EMAP). Samples from riffles were collected following NAWQA protocols, using a sampler with 425-micron net mesh-opening size from a total area of 1.25 m2 per sample in multiple riffles. Samples also were collected following EMAP protocols, using a sampler with 500-micron net mesh-opening size from a total area of 0.72 m2 per sample in multiple riffles. The taxonomic identification and enumeration of the samples followed procedures established for each program. Benthic macroinvertebrate community structure was compared between the data sets using individual metrics, a multimetric index, and multivariate analysis. Comparisons between the macroinvertebrate community structures were made after sequentially adjusting both data sets for: (1) ambiguous taxa, (2) taxonomic inconsistencies, and (3) differences in laboratory subsampling. After removal of ambiguous taxa, pair-wise differences in total taxa richness and Ephemeroptera taxa richness were statistically significant (p < 0.05). Differences between the data sets generally were not significant for richness of other taxa, tolerant taxa, semi-voltine taxa, functional feeding groups, diversity, and dominance. Sample scores calculated using the Wyoming Stream Integrity Index were not significantly different between the two data sets. After reconciling both data sets for taxonomic inconsistencies, total taxa richness and Ephemeroptera taxa richness remained significantly different between the data sets. After adjusting the data for differences in laboratory subsampling, the differences in taxa richness were no longer significant. Bray-Curtis similarity coefficients and non-metric multi-dimensional scaling were used to examine macroinvertebrate community structure. Similarity in community structure between sites was affected to a greater extent by taxa reconciliation than by adjustment for subsampling.
Montzka, S A; McFarland, M; Andersen, S O; Miller, B R; Fahey, D W; Hall, B D; Hu, L; Siso, C; Elkins, J W
2015-05-14
Global-scale atmospheric measurements are used to investigate the effectiveness of recent adjustments to production and consumption controls on hydrochlorofluorocarbons (HCFCs) under the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) and to assess recent projections of large increases in hydrofluorocarbon (HFC) production and emission. The results show that aggregate global HCFC emissions did not increase appreciably during 2007-2012 and suggest that the 2007 Adjustments to the Montreal Protocol played a role in limiting HCFC emissions well in advance of the 2013 cap on global production. HCFC emissions varied between 27 and 29 kt CFC-11-equivalent (eq)/y or 0.76 and 0.79 GtCO2-eq/y during this period. Despite slower than projected increases in aggregate HCFC emissions since 2007, total emissions of HFCs used as substitutes for HCFCs and chlorofluorocarbons (CFCs) have not increased more rapidly than rates projected [Velders, G. J. M.; Fahey, D. W.; Daniel, J. S.; McFarland, M.; Andersen, S. O. The Large Contribution of Projected HFC Emissions to Future Climate Forcing. Proc. Natl. Acad. Sci. U.S.A. 2009, 106, 10949-10954] for 2007-2012. HFC global emission magnitudes related to this substitution totaled 0.51 (-0.03, +0.04) GtCO2-eq/y in 2012, a magnitude about two times larger than emissions reported to the United Nations Framework Convention on Climate Change (UNFCCC) for these HFCs. Assuming accurate reporting to the UNFCCC, the results imply that developing countries (non-Annex I Parties) not reporting to the UNFCCC now account for nearly 50% of global HFC emissions used as substitutes for ozone-depleting substances (ODSs). Global HFC emissions (as CO2-eq) from ODS substitution can be attributed approximately equally to mobile air conditioning, commercial refrigeration, and the sum of all other applications.
Lucas, Rebekah A I; Pearson, James; Schlader, Zachary J; Crandall, Craig G
2015-11-01
What is the central question of this study? Does baroreceptor unloading during passive hyperthermia contribute to increases in ventilation and decreases in end-tidal carbon dioxide during that exposure? What is the main finding and its importance? Hyperthermic hyperventilation is not mitigated by expanding central blood volume and reloading the cardiopulmonary baroreceptors via rapid saline infusion or by reloading the arterial baroreceptors via phenylephrine administration. The absence of a reduction in ventilation upon reloading the baroreceptors to pre-hyperthermic levels indicates that cardiopulmonary and arterial baroreceptor unloading with hyperthermia is unlikely to contribute to hyperthermic hyperventilation in humans. This study tested the hypothesis that baroreceptor unloading during passive hyperthermia contributes to increases in ventilation and decreases in end-tidal partial pressure of carbon dioxide (P ET ,CO2) during that exposure. Two protocols were performed, in which healthy subjects underwent passive hyperthermia (increasing intestinal temperature by ∼1.8°C) to cause a sustained increase in ventilation and reduction in P ET ,CO2. Upon attaining hyperthermic hyperventilation, in protocol 1 (n = 10; three females) a bolus (19 ± 2 ml kg(-1) ) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to restore reductions in central venous pressure, whereas in protocol 2 (n = 11; five females) phenylephrine was infused intravenously (60-120 μg min(-1) ) to return mean arterial pressure to normothermic levels. In protocol 1, hyperthermia increased ventilation (by 2.2 ± 1.7 l min(-1) , P < 0.01), while reducing P ET ,CO2 (by 4 ± 3 mmHg, P = 0.04) and central venous pressure (by 5 ± 1 mmHg, P <0.01). Saline infusion increased central venous pressure by 5 ± 1 mmHg (P < 0.01), restoring it to normothermic values, but did not change ventilation or P ET ,CO2 (P > 0.05). In protocol 2, hyperthermia increased ventilation (by 5.0 ± 2.7 l min(-1) , P <0.01) and reduced P ET ,CO2 (by 5 ± 2 mmHg, P < 0.01) and mean arterial pressure (by 9 ± 7 mmHg, P <0.01). Phenylephrine infusion increased mean arterial pressure by 12 ± 3 mmHg (P < 0.01), restoring it to normothermic values, but did not change ventilation or P ET ,CO2 (P > 0.05). The absence of a reduction in ventilation upon reloading the cardiopulmonary and arterial baroreceptors to pre-hyperthermic levels indicates that baroreceptor unloading with hyperthermia is unlikely to contribute to hyperthermic hyperventilation in humans. © 2015 The Authors. Experimental Physiology © 2015 The Physiological Society.
Yurimoto, Terumi; Hara, Shintaro; Isoyama, Takashi; Saito, Itsuro; Ono, Toshiya; Abe, Yusuke
2016-09-01
Estimation of pressure and flow has been an important subject for developing implantable artificial hearts. To realize real-time viscosity-adjusted estimation of pressure head and pump flow for a total artificial heart, we propose the table estimation method with quasi-pulsatile modulation of rotary blood pump in which systolic high flow and diastolic low flow phased are generated. The table estimation method utilizes three kinds of tables: viscosity, pressure and flow tables. Viscosity is estimated from the characteristic that differential value in motor speed between systolic and diastolic phases varies depending on viscosity. Potential of this estimation method was investigated using mock circulation system. Glycerin solution diluted with salty water was used to adjust viscosity of fluid. In verification of this method using continuous flow data, fairly good estimation could be possible when differential pulse width modulation (PWM) value of the motor between systolic and diastolic phases was high. In estimation under quasi-pulsatile condition, inertia correction was provided and fairly good estimation was possible when the differential PWM value was high, which was not different from the verification results using continuous flow data. In the experiment of real-time estimation applying moving average method to the estimated viscosity, fair estimation could be possible when the differential PWM value was high, showing that real-time viscosity-adjusted estimation of pressure head and pump flow would be possible with this novel estimation method when the differential PWM value would be set high.
Excercise Within LBNP as an Artificial Gravity Countermeasure
NASA Technical Reports Server (NTRS)
Hargens, A. R.; Watenpaugh, D. E.; Lee, S. M. C.; Meyer, R. S.; Macias, B.; Tanaka, K.; Kimura, S.; Steinbach, G.; Groppo, E.; Khalili, N.;
2003-01-01
Previous exercise in space has lacked sufficient loads to maintain preflight cardiovascular and musculoskeletal mass and function. Lower body negative pressure (LBNP) produces a static force equivalent to one Earth body weight by each 52 mm Hg of LBNP during supine posture. LBNP also provides transmural blood pressures simulating upright exercise. Thus, this artificial-gravity concept may help maintain cardiovascular and musculoskeletal systems of crewmembers during prolonged exposure to microgravity. Currently available, bungee cord assisted, treadmill exercise is limited by harness discomfort, lower than normal loads, abnormal post-flight gait, and the absence of gravitational blood pressures within the vascular system. PURPOSE: This project evaluates a method to create artificial gravity using supine LBNP treadmill exercise to prevent loss of physiologic function in microgravity simulated by 30 days of bed rest. Identical twins were used as volunteers so that statistical power could be maximized. This countermeasure is being transitioned to space flight. CURRENT STATUS OF RESEARCH Methods: Six sets of identical twins (6 females and 14 males, 21-36 years) remained in 6 head-down tilt (HDT) bed rest for 30 days to simulate prolonged microgravity. Six subjects were randomly selected to exercise supine in an LBNP chamber for 40 minutes six days per week (EX group), while their twin brothers served as non-exercise controls (CON). Pressure within the exercise LBNP chamber was adjusted to increase load, hence increasing exercise intensity. During supine treadmill exercise, LBNP (52-63 mmHg) was applied to produce foot ward forces equivalent to those for upright running on Earth at 1.0-1.2 times body weight (BW) and subjects performed an interval exercise protocol (40-80% peak exercise capacity [VO2pk]). Five minutes of resting LBNP immediately followed each exercise session. Results: Orthostatic tolerance time decreased significantly after 30 days bed rest in the CON group, but was relatively maintained in the EX group. VO2pk was maintained in EX males, but not in CON males. Isokinetic knee strength (extension, peak torque) decreased significantly in CON males, but was preserved in EX males. The EX group had significantly higher spine muscle strength after bed rest than the CON group. The cross-sectional area of spinal muscle at L4/5 level decreased significantly in the CON group but not in the EX group. Urinary n-telopeptide excretion, an index of bone resorption, was increased during bed rest in CON, but not in EX subjects. This suggests protection by LBNP exercise against the increase in bone resorption typically seen in simulated and actual microgravity. Significant changes in bone mineral density (BMD) in the spine and ribs were observed in CON subjects, but not in EX subjects. Conclusions: Our treadmill exercise protocol within LBNP plus a short period of post-exercise LBNP maintains orthostatic responses, upright exercise capacity and other important physiologic parameters during bed rest. These results document the efficacy of our apparatus and exercise protocol for maintaining physiologic structure and function during long-duration microgravity as simulated by 30 days of HDT bed rest. FUTURE PLANS: More sets of female identical twins are needed to reach significance. The LBNP exercise chamber will be redesigned for flight.
4D pressure MRI: validation through in-vitro experiments and simulations
NASA Astrophysics Data System (ADS)
Schiavazzi, Daniele; Amili, Omid; Coletti, Filippo
2017-11-01
Advances in MRI scan technology and recently developed acquisition sequences have led to the development of 4D flow MRI, a protocol capable of characterizing in-vivo hemodynamics in patients. Thus, the availability of phase-averaged time-resolved three-dimensional blood velocities has opened new opportunities for computing a wide spectrum of totally non-invasive hemodynamic indicators. In this regard, relative pressures play a particularly important role, as they are routinely employed in the clinic to detect cardiovascular abnormalities (e.g., in peripheral artery disease, valve stenosis, hypertension, etc.). In the first part of the talk, we discuss how the relative pressures can be robustly computed through the solution of a pressure Poisson equation and how noise in the velocities affects their estimate. Routine application of these techniques in the clinic, require however a thorough validation on multiple patients/anatomies and systematic comparisons with in-vitro and simulated representations. Thus, the second part of the talk illustrates the use of numerical simulation and in-vitro experimental protocols to validate these indicators with reference to aortic and cerebral vascular anatomies.
Dutra, Rosane Menezes Faria; Neves, Itamara Lucia Itagiba; Neves, Ricardo Simões; Atik, Edmar; de Paula Santos, Ubiratan
2014-01-01
OBJECTIVES: In this observational study, we evaluated the peripheral oxygen saturation (SpO2), heart rate, and blood pressure of children with cyanotic congenital heart disease who were undergoing dental extraction. METHODS: Forty-four patients between the ages of 6 and 12 years who underwent upper primary tooth extraction were included in the study. Of these, 20 patients were in the cyanotic congenital heart disease group and 24 were in the control group. RESULTS: Peripheral oxygen saturation, heart rate, and systolic blood pressure in the cyanotic congenital heart disease group varied quite significantly during the treatment protocol (p<0.05), with values of 80.5% (±7.6) to 82.8% (±7.8), 95.3 beats per minute (bpm) (±11.3) to 101.3 bpm (±9.8), and 93.6 mm Hg (±13,3) to 103.8 mm Hg (±12.7), respectively. The variations in the control group during the procedure were also significant. CONCLUSIONS: The changes observed during the study protocol, although statistically significant, were mild and lacked clinical relevance. The results indicate that dental treatment of children with cyanotic heart disease using a standardized protocol in decentralized offices without the support of a surgical center is safe. PMID:24838895
Lansdorp, C A; van Hulst, Rob A
2018-06-01
Background Hyperbaric oxygen therapy, which consists of breathing 100% oxygen under a higher atmospheric pressure than normal, is utilized worldwide in the treatment of several diseases. With the growing demand for evidence-based research, hyperbaric oxygen therapy has been criticized for delivering too little high-quality research, mainly in the form of randomized controlled trials. While not always indispensable, the addition of a sham-controlled group to such a trial can contribute to the quality of the research. However, the design of a sham (hyperbaric) treatment is associated with several considerations regarding adequate blinding and the use of pressure and oxygen. This narrative review discusses information on the sham profile and the blinding and safety of double-blind trials in hyperbaric medicine, irrespective of the indication for treatment. Methods MEDLINE, Embase and CENTRAL were searched for sham-controlled trials on hyperbaric oxygen therapy. The control treatment was considered sham if patients were blinded to their allocation and treatment took place in a hyperbaric chamber, with no restrictions regarding pressurization, oxygen levels or indication. Studies involving children or only one session of hyperbaric oxygen were excluded. Information on (the choice of) treatment profile, blinding measures, patient's perception regarding allocation and safety issues was extracted from eligible studies. Results A total of 42 eligible trials were included. The main strategies for sham treatment were (1) use of a lower pressure than that of the hyperbaric oxygen group, while breathing 21% oxygen; (2) use of the same pressure as the hyperbaric oxygen group, while breathing an adjusted percentage of oxygen; and (3) use of the same pressure as the hyperbaric oxygen group, while breathing 21% oxygen. The advantages and disadvantages of each strategy are discussed using the information provided by the trials. Conclusion Based on this review, using a lower pressure than the hyperbaric oxygen group while breathing 21% oxygen best matches the inertness of the placebo. Although studies show that use of a lower pressure does allow adequate blinding, this is associated with more practical issues than with the other strategies. The choice of which sham profile to use requires careful consideration; moreover, to ensure proper performance, a clear and detailed protocol is also required.
Cardiorespiratory fitness and components of the metabolic syndrome in sedentary men.
Riou, Marie-Eve; Pigeon, Etienne; St-Onge, Josée; Tremblay, Angelo; Marette, André; Weisnagel, John; Joanisse, Denis R
2009-01-01
To investigate the relationships between fitness and components of the metabolic syndrome in sedentary men. 39 subjects (34-53 years) were evaluated for fitness (VO(2max)) and anthropometric, metabolic, and skeletal muscle phenotypes. VO(2max) was assessed on a bicycle ergometer whereas other variables were obtained from an oral glucose tolerance test (OGTT), hydrostatic weighing, and a muscle biopsy. Pearson and partial correlations adjusted for fat mass (FM), waist circumference (WC), muscle enzyme activities (citrate synthase (CS), cytochrome c oxidase (COX)), and capillary density were used to investigate the independent relationships be tween variables. Negative correlations between VO(2max) and WC as well as blood pressure and OGTT test were observed. When adjusted for FM, correlations remained between VO(2max) and WC (r = -0.46, p < 0.01) and systolic blood pressure (r = -0.35, p < 0.05). When adjusted for WC and CS activity, all correlations were lost except for high-sensitivity C-reactive protein (hs-CRP) (r = -0.34, p < 0.05) which remained when adjusted for CS activity. Adjustment for COX activity failed to remove correlations with hs-CRP (r = -0.36, p < 0.05), age (r = 0.34, p < 0.05), WC (r = -0.35, p < 0.05), and blood pressure. Negative correlations persisted when fitness was adjusted for the mean number of capillaries. The effects of fitness on components of the metabolic syndrome in sedentary men are explained by abdominal obesity and muscle phenotypes.
Yu, Yang; Rajagopal, Ram
2015-02-17
Two dispatch protocols have been adopted by electricity markets to deal with the uncertainty of wind power but the effects of the selection between the dispatch protocols have not been comprehensively analyzed. We establish a framework to compare the impacts of adopting different dispatch protocols on the efficacy of using wind power and implementing a carbon tax to reduce emissions. We suggest that a market has high potential to achieve greater emission reduction by adopting the stochastic dispatch protocol instead of the static protocol when the wind energy in the market is highly uncertain or the market has enough adjustable generators, such as gas-fired combustion generators. Furthermore, the carbon-tax policy is more cost-efficient for reducing CO2 emission when the market operates according to the stochastic protocol rather than the static protocol. An empirical study, which is calibrated according to the data from the Electric Reliability Council of Texas market, confirms that using wind energy in the Texas market results in a 12% CO2 emission reduction when the market uses the stochastic dispatch protocol instead of the 8% emission reduction associated with the static protocol. In addition, if a 6$/ton carbon tax is implemented in the Texas market operated according to the stochastic protocol, the CO2 emission is similar to the emission level from the same market with a 16$/ton carbon tax operated according to the static protocol. Correspondingly, the 16$/ton carbon tax associated with the static protocol costs 42.6% more than the 6$/ton carbon tax associated with the stochastic protocol.
Cotte, Uwe V; Faltenbacher, Verena H; von Willich, Werner; Bogner, Johannes R
2008-02-01
Two devices for self-measurement of blood pressure, one at the upper arm (Citizen CH-432B) and one at the wrist (Citizen CH-656C), were evaluated according to the International Protocol of the European Society of Hypertension. The International Protocol is divided into two phases: the first phase is performed on 15 selected participants with five participants in three different blood pressure ranges. If the devices passed this phase, 18 additional participants selected on the basis of the same criteria as in phase 1 were included. Two skilled observers performed the following blood pressure measurements: five measurements were performed with the mercury standard alternating with four measurements with each of the test devices per participant. The first measurement result from each device instrument was not included in the analysis. The difference between the blood pressure value given by the devices and that obtained by the two observers (mean of the two observers) was calculated for each pair of measurements and classified into three categories (within 5, 10 and 15 mmHg). The results were compared to the pass criteria established by the European Society of Hypertension. Afterwards the number of measurement differences falling within 5 mmHg was determined for every person. At least 22 of the 33 participants should have two of their three comparisons within 5 mmHg and there should be a maximum of three participants without a measurement difference within the 5 mmHg range. Both tested devices passed the first phase of the validation process by exceeding the required number of comparisons falling within the 5, 10 and 15 mmHg error zones. Even the second phase confirmed the validation criteria with average differences between the device and the mercury sphygmomanometer of 0.7+/-4.4 and -3.6+/-4.0 mmHg for systolic blood pressure and diastolic blood pressure, respectively, for the Citizen CH-432B device and -0.7+/-6.0 and -1.2+/-4.5 mmHg for the Citizen CH-656C device. Phase 2 contains furthermore an individual analysis of the 33 participants, the requirements of which were also fulfilled by both devices. The Citizen CH-432B and the Citizen CH-656C devices pass the validation recommendations of the International Protocol. They can be recommended for clinical use.
The role of the cardiac nerves in regulation of sodium excretion in conscious dogs.
Kaczmarczyk, G; Drake, A; Eisele, R; Mohnhaupt, R; Noble, M I; Simgen, B; Stubbs, J; Reinhardt, H W
1981-05-01
Conscious, chronically instrumented dogs, maintained on a high sodium intake, were used to investigate whether surgical cardiac denervation impairs the natriuresis associated with left atrial pressure increase produced in three ways: during an increase in left atrial pressure by means of a reversible mitral stenosis (protocol 1); after an i.v. saline load (1.0 ml 0.9% saline min-1 . kg-1 over 60 min) (protocol 2); after an oral saline load (14.5 mmol Na . kg-1 given with the food as isotonic solution) (protocol 3). During a reversible mitral stenosis, in intact dogs, urine volume and sodium excretion increased markedly (from 34--145 microliters . min-1 . kg-1 and from 3--12 mumol . min-1 . kg-1); mean arterial pressure increased by an average of 2 kPa (15 mm Hg) and heart rate by 53 b/min; plasma renin activity fell from 0.37--0.21 ng AI . ml-1 . h-1 . Cardiac denervation eliminated these effects of left atrial distension except for a small increase in heart rate (12 b/min). This indicates that the natriuresis and diuresis during left atrial distension resulted from stimulation of receptors located in the left atrium. In contrast, during protocol 2 and 3, the same amounts of sodium and water were excreted in the cardiac denervated dogs as compared to the intact dogs. A comparable decrease in plasma renin activity also was observed. -- Apparently the presence of the cardiac nerves is not a prerequisite for maintenance of sodium and water homeostasis.
Session: Monitoring wind turbine project sites for avian impacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, Wally
This third session at the Wind Energy and Birds/Bats workshop consisted of one presentation followed by a discussion/question and answer period. The focus of the session was on existing wind projects that are monitored for their impacts on birds and bats. The presentation given was titled ''Bird and Bat Fatality Monitoring Methods'' by Wally Erickson, West, Inc. Sections included protocol development and review, methodology, adjusting for scavenging rates, and adjusting for observer detection bias.
Zgibor, Janice C; Maloney, Maura A; Malmi, Markku; Fabio, Anthony; Kuo, Shihchen; Solano, Francis X; Tilves, Debra; Tu, Lichuan; Davidson, Mayer B
2018-01-01
To evaluate changes in HbA1c, blood pressure, and LDLc levels in participants from practices where certified diabetes educators (CDEs) implemented standardized protocols to intensify treatment compared with those receiving usual care. This clustered, randomized, clinical trial was implemented in community-based primary care practices. Fifteen primary care practices and 240 patients with type 2 diabetes were randomized to the intervention (n=175) or usual care (n=65). Participants had uncontrolled HbA1c, blood pressure, or LDLc. The one-year intervention included CDEs implementing pre-approved protocols to intensify treatment. Diabetes self-management education was also provided in both study groups. The population was 50.8% male with a mean age of 61years. The HbA1c in the intervention group decreased from 8.8% to 7.8%, (p=0.001) while the HbA1c in the usual care group increased slightly from 8.2% to 8.3%. There was also a significant difference in HbA1c between the two groups (p=0.004). There was not a significant difference between groups for systolic blood pressure (SBP) or LDLc at the end of the intervention. Those in the intervention group were more likely to have glucose-lowering medications intensified and were more likely to have their HbA1c (35% vs 15%), SBP (80% vs 77%) and HbA1c, SBP, and LDLc at goal (11% vs 1.5%) compared with the usual care group. There was no significant difference in intensification of blood pressure or cholesterol medication. Findings suggest that CDEs following standardized protocols in primary care is feasible and can effectively intensify treatment and improve glycemic control. Copyright © 2017 Elsevier Inc. All rights reserved.
Golden, Sherita Hill; Sánchez, Brisa N.; DeSantis, Amy S.; Wu, Meihua; Castro, Cecilia; Seeman, Teresa E.; Tadros, Sameh; Shrager, Sandi; Diez Roux, Ana V.
2014-01-01
Collection of salivary cortisol has become increasingly popular in large population-based studies. However, the impact of protocol compliance on day-to-day reliabilities of measures, and the extent to which reliabilities differ systematically according to socio-demographic characteristics, has not been well characterized in large-scale population-based studies to date. Using data on 935 men and women from the Multi-ethnic Study of Atherosclerosis, we investigated whether sampling protocol compliance differs systematically according to socio-demographic factors and whether compliance was associated with cortisol estimates, as well as whether associations of cortisol with both compliance and socio-demographic characteristics were robust to adjustments for one another. We further assessed the day-to-day reliability for cortisol features and the extent to which reliabilities vary according to socio-demographic factors and sampling protocol compliance. Overall, we found higher compliance among persons with higher levels of income and education. Lower compliance was significantly associated with a less pronounced cortisol awakening response (CAR) but was not associated with any other cortisol features, and adjustment for compliance did not affect associations of socio-demographic characteristics with cortisol. Reliability was higher for area under the curve (AUC) and wake up values than for other features, but generally did not vary according to socio-demographic characteristics, with few exceptions. Our findings regarding intra-class correlation coefficients (ICCs) support prior research indicating that multiple day collection is preferable to single day collection, particularly for CAR and slopes, more so than wakeup and AUC. There were few differences in reliability by socio-demographic characteristics. Thus, it is unlikely that group-specific sampling protocols are warranted. PMID:24703168
Roberts, Laura Weiss; Warner, Teddy D; Anderson, Charles T; Smithpeter, Megan V; Rogers, Melinda K
2004-04-01
To examine the perspectives and preferences regarding ethically important aspects of recruitment, consent, and debriefing of people with schizophrenia who volunteered for research protocols. A structured interview to assess research-related views of people with schizophrenia was developed and piloted. Data collection occurred at three sites. For this analysis, we examined the subset of responses from schizophrenia patients currently enrolled in a protocol. Data from 28 schizophrenia research volunteers were analyzed. Of these, 22 were men and 11 were voluntary inpatients. Most (n=23) recalled speaking with someone before enrolling in the protocol, and most (n=26) reported trusting the person who told them about it. Participants reported a moderate understanding of their protocols. All but one person (n=27) remembered signing a consent form. Twenty-one volunteers indicated that consent forms are meant to help both the patient and the researcher. Most (n=23) reported making the enrollment decision alone, with 22 making this decision prior to reviewing the consent form. The decision was described as relatively easy. Respondents felt some pressure to enroll, with women experiencing more pressure. Debriefing practices were strongly endorsed by participants. All 28 of the volunteers wished to be informed if a health problem (i.e., "something wrong") was discovered during the protocol. The persons living with schizophrenia who were interviewed for this project expressed interesting perspectives and preferences regarding ethically important aspects of recruitment, consent, and debriefing in clinical research that may help guide efforts to make research processes more attuned to participants and merit further inquiry.
Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang
2009-06-01
This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.
Prenatal exposure to the Great Chinese Famine and mid-age hypertension
Ding, Yi; Zhou, Xiuwen
2017-01-01
Background One of the most terrible famines last century was Great Chinese Famine (GCF) in 1959~1961 when millions of people died from starving. Under-nutrition during famine between the Western and Eastern (Dutch Hungry vs. GCF) was similar, while cardiovascular consequences might not be the same. Addressing such questions may gain new insight into prevention of cardiovascular diseases. Methods A retrospective cohort of 18,593 participants aged 43–49 years of old, was from Suzhou, China. Logistic regression model was used to calculate the relative risk (RR) of hypertension and corresponding 95% confidence interval (CI). The multivariate RRs were adjusted for age, plasma glucose, triglyceride, and cholesterol. Results The multivariate RRs of systolic and diastolic pressure were not significantly elevated in the rural subgroups, but was higher in the urban population born in the famine (systolic pressure adjust RR 1.382, 95% CI 1.235–1.545, diastolic pressure adjust RR 1.569, 95% CI 1.415–1.740). The risks of hypertension were significantly higher among the urban subjects than that in the rural subgroups (systolic hypertension adjust RR 2.915, 95% CI 2.616–3.249, diastolic hypertension adjust RR 4.568, 95% CI 4.079–5.116). Percentile of optimal diastolic pressure at mid-age was significantly lower in the urban population prenatally exposed to the famine regardless of sexes. However, a similar reduction of percentage of optimal systolic pressure was only seen in the female, not the male population in the urban region. Conclusion The data suggest Asian genetic basis was not able to block famine-programmed vascular diseases as that happened in Europe, and the programmed problems due to under-nutrition could be reversed after birth. Protective mechanisms may be related to diet habits before age of 30 years old, which is important contribution to early prevention of hypertension. PMID:28498832
[Mechanism of neoglottic adjustment for voice variation in tracheoesophageal speech].
Fujimoto, T; Kinishi, M; Mohri, M; Amatsu, M
1994-06-01
Over the past 17 years, we have been performing tracheoesophageal (TE) fistulization for voice restoration following total laryngectomy. The purpose of this technique is to divert the exhaled air through the TE fistula into the hypopharynx where the inferior constrictor muscle forms the retropharyngeal prominence on which the neoglottis is located. It is generally accepted that both pulmonary power and laryngeal adjustment control voice frequency and intensity change in laryngeal phonation. Regularity at various pitches and voice intensities was seen in TE phonation, despite laryngeal adjustment being lost. Regular voice production with various pitches and intensities requires a regulatory mechanism for both pulmonary power and the neoglottis. This study was designed to clarify the mechanism of neoglottic adjustment in TE phonation. Ten speakers with TE fistula were subjected to aerodynamic and electrophysiological investigations. Tracheal pressure, fundamental frequency, intensity, and airflow rate were measured for easy phonation, a high-pitched voice, and a loud voice. Resistance and efficiency of the neoglottis were calculated from the data obtained. Electromyograms of the inferior constrictor muscle and tracheal pressure were simultaneously recorded when the pitch or intensity of the voice increased. Six of the ten subjects examined were able to produce a high-pitched voice. Tracheal pressure increased in all six, the airflow rate in four, and neoglottal resistance in five, as compared with the data obtained during easy phonation. Nine of the ten subjects examined were able to produce a loud voice. In all nine, both tracheal pressure and the airflow rate increased as compared with the values measured during easy phonation. Neoglottal resistance had no definite pattern in relation to voice intensity changes. Electrophysiological study demonstrated that the activity of the inferior constrictor muscle increased as tracheal pressure increased so as to raise the pitch or increase the intensity of the voice. These results indicate that the adjustment of neoglottic closure and stiffness produced by the inferior constrictor muscle has the role of varying the frequency or intensity of the voice.
Gender identity: a multidimensional analysis with implications for psychosocial adjustment.
Egan, S K; Perry, D G
2001-07-01
This study examined the relations between components of gender identity and psychosocial adjustment. The aspects of gender identity assessed were (a) feelings of psychological compatibility with one's gender (i.e.. feeling one is a typical member of one's sex and feeling content with one's biological sex), (b) feelings of pressure from parents, peers, and self for conformity to gender stereotypes. and (c) the sentiment that one's own sex is superior to the other (intergroup bias). Adjustment was assessed in terms of self-esteem and peer acceptance. Participants were 182 children in Grades 4 through 8. Felt gender compatibility (when operationalized as either self-perceived gender typicality or feelings of contentment with one's biological sex) was positively related to adjustment, whereas felt pressure and intergroup bias were negatively associated with adjustment. The results provide new insights into the role of gender identity in children's well-being, help identify sources of confusion in previous work, and suggest directions for future inquiry.
Measuring bioenergetics in T cells using a Seahorse Extracellular Flux Analyzer
van der Windt, Gerritje J.W.; Chang, Chih-Hao; Pearce, Erika L.
2016-01-01
This unit contains several protocols to determine the energy utilization of T cells in real-time using a Seahorse Extracellular Flux Analyzer (www.seahorsebio.com). The advantages to using this machine over traditional metabolic assays include the simultaneous measurement of glycolysis and mitochondrial respiration, in real-time, on relatively small numbers of cells, without any radioactivity. The Basic Protocol describes a standard mitochondrial stress test on the XFe96, which yields information about oxidative phosphorylation and glycolysis, two energy-generating pathways. The alternate protocols provide examples of adaptations to the Basic Protocol, including adjustments for the use of the XFe24. A protocol for real-time bioenergetic responses to T cell activation allows for the analysis of immediate metabolic changes after T cell receptor stimulation. Specific substrate utilization can be determined by the use of differential assay media, or the injection of drugs that specifically affect certain metabolic processes. Accurate cell numbers, purity, and viability are critical to obtain reliable results. PMID:27038461
Measuring Bioenergetics in T Cells Using a Seahorse Extracellular Flux Analyzer.
van der Windt, Gerritje J W; Chang, Chih-Hao; Pearce, Erika L
2016-04-01
This unit contains several protocols to determine the energy utilization of T cells in real-time using a Seahorse Extracellular Flux Analyzer (http://www.seahorsebio.com). The advantages to using this machine over traditional metabolic assays include the simultaneous measurement of glycolysis and mitochondrial respiration, in real-time, on relatively small numbers of cells, without any radioactivity. The Basic Protocol describes a standard mitochondrial stress test on the XF(e) 96, which yields information about oxidative phosphorylation and glycolysis, two energy-generating pathways. The alternate protocols provide examples of adaptations to the Basic Protocol, including adjustments for the use of the XF(e) 24. A protocol for real-time bioenergetic responses to T cell activation allows for the analysis of immediate metabolic changes after T cell receptor stimulation. Specific substrate utilization can be determined by the use of differential assay media, or the injection of drugs that specifically affect certain metabolic processes. Accurate cell numbers, purity, and viability are critical to obtain reliable results. Copyright © 2016 John Wiley & Sons, Inc.
NASA Astrophysics Data System (ADS)
Balcerzyk, Marcin; Fernández-López, Rosa; Parrado-Gallego, Ángel; Pachón-Garrudo, Víctor Manuel; Chavero-Royan, José; Hevilla, Juan; Jiménez-Ortega, Elisa; Leal, Antonio
2017-11-01
Tumour uptake value is a critical result in [18F]FDG-PET/CT ([18F]fluorodeoxyglucose) quantitative scans such as the dose prescription for radiotherapy and oncology. The quantification is highly dependent on the protocol of acquisition and reconstruction of the image, especially in low activity tumours. During adjusting acquisition and reconstruction protocols available in our Siemens Biograph mCT scanner for EARL (ResEARch 4 Life®) [18F]FDG-PET/CT accreditation requirements, we developed reconstruction protocols which will be used in PET based radiotherapy planning able to reduce inter-/intra-institute variability in Standard Uptake Value (SUV) results, and to bring Recovery Coefficient to 1 as close as possible for Image Quality NEMA 2007 phantom. Primary and secondary tumours from two patients were assessed by four independent evaluators. The influence of reconstruction protocols on tumour clinical assessment was presented. We proposed the improvement route for EARL accredited protocols so that they may be developed in classes to take advantage of scanner possibilities. The application of optimized reconstruction protocol eliminates the need of partial volume corrections.
Modelling the protocol stack in NCS with deterministic and stochastic petri net
NASA Astrophysics Data System (ADS)
Hui, Chen; Chunjie, Zhou; Weifeng, Zhu
2011-06-01
Protocol stack is the basis of the networked control systems (NCS). Full or partial reconfiguration of protocol stack offers both optimised communication service and system performance. Nowadays, field testing is unrealistic to determine the performance of reconfigurable protocol stack; and the Petri net formal description technique offers the best combination of intuitive representation, tool support and analytical capabilities. Traditionally, separation between the different layers of the OSI model has been a common practice. Nevertheless, such a layered modelling analysis framework of protocol stack leads to the lack of global optimisation for protocol reconfiguration. In this article, we proposed a general modelling analysis framework for NCS based on the cross-layer concept, which is to establish an efficiency system scheduling model through abstracting the time constraint, the task interrelation, the processor and the bus sub-models from upper and lower layers (application, data link and physical layer). Cross-layer design can help to overcome the inadequacy of global optimisation based on information sharing between protocol layers. To illustrate the framework, we take controller area network (CAN) as a case study. The simulation results of deterministic and stochastic Petri-net (DSPN) model can help us adjust the message scheduling scheme and obtain better system performance.
Debaty, Guillaume; Metzger, Anja; Rees, Jennifer; McKnite, Scott; Puertas, Laura; Yannopoulos, Demetris; Lurie, Keith
2016-01-01
Objective To improve the likelihood for survival with favorable neurologic function after cardiac arrest, we assessed a new advanced life support approach using active compression-decompression cardiopulmonary resuscitation plus an intrathoracic pressure regulator. Design Prospective animal investigation. Setting Animal laboratory. Subjects Female farm pigs (n = 25) (39 ± 3 kg). Interventions Protocol A: After 12 minutes of untreated ventricular fibrillation, 18 pigs were randomized to group A—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with standard cardiopulmonary resuscitation; group B—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator; and group C—3 minutes of basic life support with active compression-decompression cardiopulmonary resuscitation plus an impedance threshold device, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator. Advanced life support always included IV epinephrine (0.05 μg/kg). The primary endpoint was the 24-hour Cerebral Performance Category score. Protocol B: Myocardial and cerebral blood flow were measured in seven pigs before ventricular fibrillation and then following 6 minutes of untreated ventricular fibrillation during sequential 5 minutes treatments with active compression-decompression plus impedance threshold device, active compression-decompression plus intrathoracic pressure regulator, and active compression-decompression plus intrathoracic pressure regulator plus epinephrine. Measurements and Main Results Protocol A: One of six pigs survived for 24 hours in group A versus six of six in groups B and C (p = 0.002) and Cerebral Performance Category scores were 4.7 ± 0.8, 1.7 ± 0.8, and 1.0 ± 0, respectively (p = 0.001). Protocol B: Brain blood flow was significantly higher with active compression-decompression plus intrathoracic pressure regulator compared with active compression-decompression plus impedance threshold device (0.39 ± 0.23 vs 0.27 ± 0.14 mL/min/g; p = 0.03), whereas differences in myocardial perfusion were not statistically significant (0.65 ± 0.81 vs 0.42 ± 0.36 mL/min/g; p = 0.23). Brain and myocardial blood flow with active compression-decompression plus intrathoracic pressure regulator plus epinephrine were significantly increased versus active compression-decompression plus impedance threshold device (0.40 ± 0.22 and 0.84 ± 0.60 mL/min/g; p = 0.02 for both). Conclusion Advanced life support with active compression-decompression plus intrathoracic pressure regulator significantly improved cerebral perfusion and 24-hour survival with favorable neurologic function. These findings support further evaluation of this new advanced life support methodology in humans. PMID:25756411
Lin, Michael Y; Catalano, Paul; Dennerlein, Jack T
2016-06-01
The aim of this study was to determine user self-selected setup for both sitting and standing computer workstations and identify major differences. No current ergonomic setup guideline for standing computer workstations is available. Twenty adult participants completed four 45-min sessions of simulated office computer work with an adjustable sit-stand computer workstation. Placement and relative position of all workstation components, including a cordless mouse, a cordless keyboard, a height-adjustable desk, and a 22-inch monitor mounted on a mechanical-assisted arm were recorded during the four sessions, which alternated between sitting and standing for each session. Participants were interrupted four times within each session, and the workstation was "reset" to extreme locations. Participants were instructed to adjust the location to achieve the most comfortable arrangement and to make as many adjustments during the session to achieve this goal. Overall, users placed the keyboard closer to their body (sternum), set desk height lower than their elbow, and set the monitor lower relative to their eyes with a greater upward tilt while standing compared to sitting. During the 45-min sessions, the number of adjustments participants made became smaller and over the four sessions was consistent, suggesting the psychophysical protocol was effective and consistent. Users preferred different workstation setups for sitting and standing computer workstations. Therefore, future setup guidelines and principles for standing computer workstations may not be simply translated from those for sitting. These results can serve as the first step toward making recommendations to establish ergonomic guidelines for standing computer workstation arrangement. © 2016, Human Factors and Ergonomics Society.
Sevransky, Jonathan E; Checkley, William; Herrera, Phabiola; Pickering, Brian W; Barr, Juliana; Brown, Samuel M; Chang, Steven Y; Chong, David; Kaufman, David; Fremont, Richard D; Girard, Timothy D; Hoag, Jeffrey; Johnson, Steven B; Kerlin, Mehta P; Liebler, Janice; O'Brien, James; O'Keefe, Terence; Park, Pauline K; Pastores, Stephen M; Patil, Namrata; Pietropaoli, Anthony P; Putman, Maryann; Rice, Todd W; Rotello, Leo; Siner, Jonathan; Sajid, Sahul; Murphy, David J; Martin, Greg S
2015-10-01
Clinical protocols may decrease unnecessary variation in care and improve compliance with desirable therapies. We evaluated whether highly protocolized ICUs have superior patient outcomes compared with less highly protocolized ICUs. Observational study in which participating ICUs completed a general assessment and enrolled new patients 1 day each week. A total of 6,179 critically ill patients. Fifty-nine ICUs in the United States Critical Illness and Injury Trials Group Critical Illness Outcomes Study. None. The primary exposure was the number of ICU protocols; the primary outcome was hospital mortality. A total of 5,809 participants were followed prospectively, and 5,454 patients in 57 ICUs had complete outcome data. The median number of protocols per ICU was 19 (interquartile range, 15-21.5). In single-variable analyses, there were no differences in ICU and hospital mortality, length of stay, use of mechanical ventilation, vasopressors, or continuous sedation among individuals in ICUs with a high versus low number of protocols. The lack of association was confirmed in adjusted multivariable analysis (p = 0.70). Protocol compliance with two ventilator management protocols was moderate and did not differ between ICUs with high versus low numbers of protocols for lung protective ventilation in acute respiratory distress syndrome (47% vs 52%; p = 0.28) and for spontaneous breathing trials (55% vs 51%; p = 0.27). Clinical protocols are highly prevalent in U.S. ICUs. The presence of a greater number of protocols was not associated with protocol compliance or patient mortality.
Standardized quality-assessment system to evaluate pressure ulcer care in the nursing home.
Bates-Jensen, Barbara M; Cadogan, Mary; Jorge, Jennifer; Schnelle, John F
2003-09-01
To demonstrate reliability and feasibility of a standardized protocol to assess and score quality indicators relevant to pressure ulcer (PU) care processes in nursing homes (NHs). Descriptive. Eight NHs. One hundred ninety-one NH residents for whom the PU Resident Assessment Protocol of the Minimum Data Set was initiated. Nine quality indicators (two related to screening and prevention of PU, two focused on assessment, and five addressing management) were scored using medical record data, direct human observation, and wireless thigh monitor observation data. Feasibility and reliability of medical record, observation, and thigh monitor protocols were determined. The percentage of participants who passed each of the indicators, indicating care consistent with practice guidelines, ranged from 0% to 98% across all indicators. In general, participants in NHs passed fewer indicators and had more problems with medical record accuracy before a PU was detected (screening/prevention indicators) than they did once an ulcer was documented (assessment and management indicators). Reliability of the medical record protocol showed kappa statistics ranging from 0.689 to 1.00 and percentage agreement from 80% to 100%. Direct observation protocols yielded kappa statistics of 0.979 and 0.928. Thigh monitor protocols showed kappa statistics ranging from 0.609 to 0.842. Training was variable, with the observation protocol requiring 1 to 2 hours, medical records requiring joint review of 20 charts with average time to complete the review of 20 minutes, and the thigh monitor data requiring 1 week for training in data preparation and interpretation. The standardized quality assessment system generated scores for nine PU quality indicators with good reliability and provided explicit scoring rules that permit reproducible conclusions about PU care. The focus of the indicators on care processes that are under the control of NH staff made the protocol useful for external survey and internal quality improvement purposes, and the thigh monitor observational technology provided a method for monitoring repositioning care processes that were otherwise difficult to monitor and manage.
Khemani, Robinder G; Sward, Katherine; Morris, Alan; Dean, J Michael; Newth, Christopher J L
2011-11-01
Although pediatric intensivists claim to embrace lung protective ventilation for acute lung injury (ALI), ventilator management is variable. We describe ventilator changes clinicians made for children with hypoxemic respiratory failure, and evaluate the potential acceptability of a pediatric ventilation protocol. This was a retrospective cohort study performed in a tertiary care pediatric intensive care unit (PICU). The study period was from January 2000 to July 2007. We included mechanically ventilated children with PaO(2)/FiO(2) (P/F) ratio less than 300. We assessed variability in ventilator management by evaluating actual changes to ventilator settings after an arterial blood gas (ABG). We evaluated the potential acceptability of a pediatric mechanical ventilation protocol we adapted from National Institutes of Health/National Heart, Lung, and Blood Institute (NIH/NHLBI) Acute Respiratory Distress Syndrome (ARDS) Network protocols by comparing actual practice changes in ventilator settings to changes that would have been recommended by the protocol. A total of 2,719 ABGs from 402 patients were associated with 6,017 ventilator settings. Clinicians infrequently decreased FiO(2), even when the PaO(2) was high (>68 mmHg). The protocol would have recommended more positive end expiratory pressure (PEEP) than was used in actual practice 42% of the time in the mid PaO(2) range (55-68 mmHg) and 67% of the time in the low PaO(2) range (<55 mmHg). Clinicians often made no change to either peak inspiratory pressure (PIP) or ventilator rate (VR) when the protocol would have recommended a change, even when the pH was greater than 7.45 with PIP at least 35 cmH(2)O. There may be lost opportunities to minimize potentially injurious ventilator settings for children with ALI. A reproducible pediatric mechanical ventilation protocol could prompt clinicians to make ventilator changes that are consistent with lung protective ventilation.
Biomechanical investigation of prolonged driving in an ergonomically designed truck seat prototype.
Cardoso, Michelle; McKinnon, Colin; Viggiani, Dan; Johnson, Michel J; Callaghan, Jack P; Albert, Wayne J
2018-03-01
A postural evaluation during a prolonged driving task was conducted to determine the ergonomic validity of a new freely adjustable truck seat prototype. Twenty participants were recruited to perform two 2-h simulated driving sessions. Postures were assessed using motion capture, accelerometers and pressure pads. Subjective discomfort was also monitored in 15-min increments using ratings of perceived discomfort (RPD) and the Automotive Seating Discomfort Questionnaire. Participants had a more neutral spine posture during the first hour of the drive and reported lower RPDs while sitting in the prototype. Pairing the gluteal backrest panel with the adjustable seat pan helped reduce the average sitting pressure. The industry-standard truck seat may lead to the development of poor whole body posture, and the proposed ergonomic redesign of a new truck seat helped improve sitting posture and reduce perceived discomfort. Practitioner Summary: A new freely adjustable truck seat prototype was compared to an Industry standard seat to assess hypothesised improvements to sitting posture and discomfort for long haul driving. It was found that the adjustable panels in the prototype helped promote spine posture, reduce sitting pressure and improved discomfort ratings.
Correction of aortic insufficiency with an external adjustable prosthetic aortic ring.
Gogbashian, Andrew; Ghanta, Ravi K; Umakanthan, Ramanan; Rangaraj, Aravind T; Laurence, Rita G; Fox, John A; Cohn, Lawrence H; Chen, Frederick Y
2007-09-01
Less invasive, valve-sparing options are needed for patients with aortic insufficiency (AI). We sought to evaluate the feasibility of reducing AI with an external adjustable aortic ring in an ovine model. To create AI, five sheep underwent patch plasty enlargement of the aortic annulus and root by placement of a 10 x 15 mm pericardial patch between the right and noncoronary cusps. An adjustable external ring composed of a nylon band was fabricated and placed around the aortic root. Aortic flow, aortic pressure, and left ventricular pressures were measured with the ring loose (off) and tightened (on). Mean regurgitant orifice area decreased by 86%, from 0.07 +/- 0.03 cm2 (ring loose, off) to 0.01 +/- 0.00 cm2 (ring tightened, on) [p < 0.01]. The regurgitant fraction decreased from 18 +/- 4% to 2 +/- 1% [p < 0.01]. The ring did not significantly affect stroke volume and aortic pressure. An ovine model of aortic root dilatation resulting in acute AI has been developed. In this model, application of an external, adjustable constricting aortic ring eliminated AI. An aortic ring may be a useful adjunct in reducing AI secondary to annular dilatation.
Skruibis, Paulius; Eimontas, Jonas; Dovydaitiene, Migle; Mazulyte, Egle; Zelviene, Paulina; Kazlauskas, Evaldas
2016-07-26
Adjustment disorder is one of the most common mental health diagnoses. Still it receives relatively little attention from researchers trying to establish best interventions to treat it. With high prevalence of stressful life events, which might be leading to adjustment disorder, and limited resources of mental health service providers, online interventions could be a very practical way of helping people who have these disorders or are in the risk to develop them. The proposed study protocol is aimed to describe a randomized controlled trial of an internet-based modular intervention for adjustment disorder as it is defined in a proposal for the ICD-11. This study is a two-armed Randomized Controlled Trial (RCT) to examine the effectiveness of a web-based intervention BADI (Brief Adjustment Disorder Intervention) for adjustment disorder symptoms. BADI has four modules: Relaxation, Time management, Mindfulness and Strengthening relationships. It is based on stress and coping research and integrates evidence-based treatment approaches such as Cognitive Behavioural therapy (CBT), mindfulness and body-mind practices, as well as exercises for enhancing social support. Primary outcome of the study are symptoms of adjustment disorder and well-being. Engagement into the program and motivation for change is a secondary outcome. All participants after completing the baseline assessment are randomly assigned to one of the two groups: either to the one in which participant will instantly gain access to the BADI intervention or a group in which participants will be given access to the BADI program after waiting one month. Participants of BADI can choose exercises of the program flexibly. There is no particular order in which the exercises should be completed. Study will provide new insights of modular internet-based interventions efficacy for adjustment disorders. The study will also provide information about the role of motivation and expectancies on engagement in modular internet-based interventions. In case this RCT supports effectiveness of fully automated version of BADI, it could be used very broadly. It could become a cost-effective and accessible intervention for adjustment disorder. The study was retrospectively registered with the Australian and New Zealand Clinical Trials Registry with the registration number ACTRN12616000883415 . Registered 5 July, 2016.
Quantitative assessment of early diabetic retinopathy using fractal analysis.
Cheung, Ning; Donaghue, Kim C; Liew, Gerald; Rogers, Sophie L; Wang, Jie Jin; Lim, Shueh-Wen; Jenkins, Alicia J; Hsu, Wynne; Li Lee, Mong; Wong, Tien Y
2009-01-01
Fractal analysis can quantify the geometric complexity of the retinal vascular branching pattern and may therefore offer a new method to quantify early diabetic microvascular damage. In this study, we examined the relationship between retinal fractal dimension and retinopathy in young individuals with type 1 diabetes. We conducted a cross-sectional study of 729 patients with type 1 diabetes (aged 12-20 years) who had seven-field stereoscopic retinal photographs taken of both eyes. From these photographs, retinopathy was graded according to the modified Airlie House classification, and fractal dimension was quantified using a computer-based program following a standardized protocol. In this study, 137 patients (18.8%) had diabetic retinopathy signs; of these, 105 had mild retinopathy. Median (interquartile range) retinal fractal dimension was 1.46214 (1.45023-1.47217). After adjustment for age, sex, diabetes duration, A1C, blood pressure, and total cholesterol, increasing retinal vascular fractal dimension was significantly associated with increasing odds of retinopathy (odds ratio 3.92 [95% CI 2.02-7.61] for fourth versus first quartile of fractal dimension). In multivariate analysis, each 0.01 increase in retinal vascular fractal dimension was associated with a nearly 40% increased odds of retinopathy (1.37 [1.21-1.56]). This association remained after additional adjustment for retinal vascular caliber. Greater retinal fractal dimension, representing increased geometric complexity of the retinal vasculature, is independently associated with early diabetic retinopathy signs in type 1 diabetes. Fractal analysis of fundus photographs may allow quantitative measurement of early diabetic microvascular damage.
Measuring ocular characteristics after gel injection adjustable keratoplasty (GIAK) in the rabbit
NASA Astrophysics Data System (ADS)
Comander, Jason I.; Parel, Jean-Marie A.; Simon, Gabriel; Takesue, Yoshiko; Villain, Franck L.
1995-05-01
Gel Injection Adjustable Keratoplasty (GIAK) is a refractive surgery procedure which uses an ocular ring implant made of a polyethylene oxide hydrogel to cause a refractive change in the cornea. Unlike laser photo refractive keratectomy, GIAK does not interfere with the central cornea because the ring lies around the optical axis. Thus, vision can be assessed immediately after surgery. Our in vivo study was designed to quantify GIAK's effects on tissues, the biocompatibility of the polymer and in the process investigate which ocular changes in the rabbit model can be monitored with precision using current technology. Thirty-two young rabbits underwent a delamination in one eye, 22 of which were injected with a new polymeric gel. Corneal topography, keratometry, pachymetry, and tonometry were performed on both eyes for up to 105 days. All corneas flattened with growth. In GIAK animals, we found an average flattening of 6.51 +/- 1.23 diopters (p < 0.0001) relative to the fellow eye. No statistically significant regression over the 102 days was observed. Intraocular pressure dropped slightly by 0.69 +/- 1.21 mmHg (p equals 0.025), a clinically insignificant value, while no significant change was detected in corneal thickness. Keratometry can be tracked in rabbits after GIAK surgery from POD 1. Measuring unoperated fellow eyes allows for the effects of surgery to be assessed without bias from growth. Using this protocol, GIAK was shown to be stable. It was more difficult to draw conclusions from pachymetry, tonometry, and topography data.
Smoking cessation and outcome after ischemic stroke or TIA.
Epstein, Katherine A; Viscoli, Catherine M; Spence, J David; Young, Lawrence H; Inzucchi, Silvio E; Gorman, Mark; Gerstenhaber, Brett; Guarino, Peter D; Dixit, Anand; Furie, Karen L; Kernan, Walter N
2017-10-17
To assess whether smoking cessation after an ischemic stroke or TIA improves outcomes compared to continued smoking. We conducted a prospective observational cohort study of 3,876 nondiabetic men and women enrolled in the Insulin Resistance Intervention After Stroke (IRIS) trial who were randomized to pioglitazone or placebo within 180 days of a qualifying stroke or TIA and followed up for a median of 4.8 years. A tobacco use history was obtained at baseline and updated during annual interviews. The primary outcome, which was not prespecified in the IRIS protocol, was recurrent stroke, myocardial infarction (MI), or death. Cox regression models were used to assess the differences in stroke, MI, and death after 4.8 years, with correction for adjustment variables prespecified in the IRIS trial: age, sex, stroke (vs TIA) as index event, history of stroke, history of hypertension, history of coronary artery disease, and systolic and diastolic blood pressures. At the time of their index event, 1,072 (28%) patients were current smokers. By the time of randomization, 450 (42%) patients had quit smoking. Among quitters, the 5-year risk of stroke, MI, or death was 15.7% compared to 22.6% for patients who continued to smoke (adjusted hazard ratio 0.66, 95% confidence interval 0.48-0.90). Cessation of cigarette smoking after an ischemic stroke or TIA was associated with significant health benefits over 4.8 years in the IRIS trial cohort. © 2017 American Academy of Neurology.
Choi, Younsung; Lee, Donghoon; Kim, Jiye; Jung, Jaewook; Nam, Junghyun; Won, Dongho
2014-01-01
Wireless sensor networks (WSNs) consist of sensors, gateways and users. Sensors are widely distributed to monitor various conditions, such as temperature, sound, speed and pressure but they have limited computational ability and energy. To reduce the resource use of sensors and enhance the security of WSNs, various user authentication protocols have been proposed. In 2011, Yeh et al. first proposed a user authentication protocol based on elliptic curve cryptography (ECC) for WSNs. However, it turned out that Yeh et al.'s protocol does not provide mutual authentication, perfect forward secrecy, and key agreement between the user and sensor. Later in 2013, Shi et al. proposed a new user authentication protocol that improves both security and efficiency of Yeh et al.'s protocol. However, Shi et al.'s improvement introduces other security weaknesses. In this paper, we show that Shi et al.'s improved protocol is vulnerable to session key attack, stolen smart card attack, and sensor energy exhausting attack. In addition, we propose a new, security-enhanced user authentication protocol using ECC for WSNs. PMID:24919012
Choi, Younsung; Lee, Donghoon; Kim, Jiye; Jung, Jaewook; Nam, Junghyun; Won, Dongho
2014-06-10
Wireless sensor networks (WSNs) consist of sensors, gateways and users. Sensors are widely distributed to monitor various conditions, such as temperature, sound, speed and pressure but they have limited computational ability and energy. To reduce the resource use of sensors and enhance the security of WSNs, various user authentication protocols have been proposed. In 2011, Yeh et al. first proposed a user authentication protocol based on elliptic curve cryptography (ECC) for WSNs. However, it turned out that Yeh et al.'s protocol does not provide mutual authentication, perfect forward secrecy, and key agreement between the user and sensor. Later in 2013, Shi et al. proposed a new user authentication protocol that improves both security and efficiency of Yeh et al.'s protocol. However, Shi et al.'s improvement introduces other security weaknesses. In this paper, we show that Shi et al.'s improved protocol is vulnerable to session key attack, stolen smart card attack, and sensor energy exhausting attack. In addition, we propose a new, security-enhanced user authentication protocol using ECC for WSNs.
Isgrò, S; Zanella, A; Giani, M; Abd El Aziz El Sayed Deab, S; Pesenti, A; Patroniti, N
2012-10-01
Aim of the paper was to assess the performance of different expiratory valves and the resistance of helmet outlet ports at increasing gas flow rates. A gas flow-meter was connected to 10 different expiratory peep valves: 1 water-seal valve, 4 precalibrated fixed PEEP valves and 5 adjustable PEEP valves. Three new valves of each brand, set at different pressure levels (5-7.5-10-12.5-15 cmH(2)O, if available), were tested at increasing gas flow rates (from 30 to 150 L/min). We measured the pressure generated just before the valves. Three different helmets sealed on a mock head were connected at the inlet port with a gas flow-meter while the outlet was left clear. We measured the pressure generated inside the helmet (due to the flow-resistance of the outlet port) at increasing gas flow rates. Adjustable valves showed a variable degree flow-dependency (increasing difference between the measured and the expected pressure at increasing flow rates), while pre-calibrated valves revealed a flow-independent behavior. Water seal valve showed low degree flow-dependency. The pressures generated by the outlet port of the tested helmets ranged from 0.02 to 2.29 cmH(2)O at the highest gas flow rate. Adjustable PEEP valves are not suggested for continuous-flow CPAP systems as their flow-dependency can lead to pressures higher than expected. Precalibrated and water seal valves exhibit the best performance. Different helmet outlet ports do not significantly affect the pressure generated during helmet CPAP. In order to avoid iatrogenic complications gas flow and pressure delivered during helmet CPAP must always be monitored.
COMT GENOTYPE INFLUENCES THE EFFECT OF ALCOHOL ON BLOOD PRESSURE: RESULTS FROM THE COMBINE STUDY
Stewart, SH; Oroszi, G; Randall, PK; Anton, RF
2009-01-01
Background Heavy drinking can cause chronic hypertension, possibly due to effects on the autonomic nervous system. Catechol-O-methyltransferase (COMT) inactivates catecholamines, and a G to A substitution in codon 108 in the soluble COMT mRNA (or codon 158 in the membrane bound form) substitutes methionine for valine and alters enzyme activity. Methods We evaluated the association of COMT genotype at this locus with blood pressure in 839 alcohol dependent individuals before and during participation in an alcoholism treatment trial. Hierarchical linear models were used to account for within-subject correlation on repeated blood pressure measurements, and findings were adjusted for age, gender, ethnicity, alcohol use, body-mass index, current smoking, hypertension history, and study site. Results Relative to those with the val-val genotype, those with the met-met genotype had higher adjusted systolic (+4.9 mm Hg, p<0.01) and diastolic (+3.2 mm Hg, p<0.01) blood pressure at baseline. Those with the val-met genotype did not significantly differ from the val-val genotype. Changes in blood pressure between baseline and 4 weeks of alcohol treatment also differed by genotype. Relative to the val-val genotype, the met-met genotype had a greater reduction in adjusted systolic pressure (-3.9 mm Hg, p<0.01) and diastolic pressure (-2.8 mm Hg, p<0.01). Corresponding relative reductions for the val-met genotype were -2.2 mm Hg systolic (p=0.070) and -1.5 mm Hg diastolic (p<0.05). Conclusion Findings suggest that alcohol-induced blood pressure elevation may be related to the effects of catecholamines and their genetically determined inactivation. PMID:19023276
Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland
2014-01-01
Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. All four tested devices passed the validation process. The mean differences between the device and mercury readings were: -1.8±5.1 mmHg and -0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and -1.2±4.3 mmHg for the Omron HEM-7420 device; -0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly.
Evaluation of Pressure Pain Threshold as a Measure of Perceived Stress and High Job Strain.
Hven, Lisbeth; Frost, Poul; Bonde, Jens Peter Ellekilde
2017-01-01
To investigate whether pressure pain threshold (PPT), determined by pressure algometry, can be used as an objective measure of perceived stress and job strain. We used cross-sectional base line data collected during 1994 to 1995 within the Project on Research and Intervention in Monotonous work (PRIM), which included 3123 employees from a variety of Danish companies. Questionnaire data included 18 items on stress symptoms, 23 items from the Karasek scale on job strain, and information on discomfort in specified anatomical regions was also collected. Clinical examinations included pressure pain algometry measurements of PPT on the trapezius and supraspinatus muscles and the tibia. Associations of stress symptoms and job strain with PPT of each site was analyzed for men and women separately with adjustment for age body mass index, and discomfort in the anatomical region closest to the point of pressure algometry using multivariable linear regression. We found significant inverse associations between perceived stress and PPT in both genders in models adjusting for age and body mass index: the higher level of perceived stress, the lower the threshold. For job strain, associations were weaker and only present in men. In men all associations were attenuated when adjusting for reported discomfort in regions close to the site of pressure algometry. The distributions of PPT among stressed and non-stressed persons were strongly overlapping. Despite significant associations between perceived stress and PPT, the discriminative capability of PPT to distinguish individuals with and without stress is low. PPT measured by pressure algometry seems not applicable as a diagnostic tool of a state of mental stress.
The LISST-SL streamlined isokinetic suspended-sediment profiler
Gray, John R.; Agrawal, Yogesh C.; Pottsmith, H. Charles
2004-01-01
The new manually deployed Laser In Situ Scattering Transmissometer-StreamLined profiler (LISST-SL) represents a major technological advance for suspended-sediment measurements in rivers. The LISST-SL is being designed to provide real-time data on sediment concentrations and particle-size distributions. A pressure sensor and current meter provide real-time depth and ambient velocity data, respectively. The velocity data are also used to control pumpage across an internal laser so that the intake velocity is constantly adjusted to match the ambient stream velocity. Such isokinetic withdrawal is necessary for obtaining representative sedimentary measurements in streamflow, and ensures compliance with established practices. The velocity and sediment-concentration data are used to compute fluxes for up to 32 particle-size classes at points, verticals, or in the entire stream cross section. All data are stored internally, as well as transmitted via a 2-wire conductor to the operator using a specially developed communication protocol. The LISST-SL's performance will be measured and compared to published sedimentological accuracy criteria, and a performance summary will be placed on-line.
Leazer, Johnnie L; Gant, Sean; Houck, Anthony; Leonard, William; Welch, Christopher J
2009-03-15
Supercritical CO2 extraction of aqueous streams is a convenient and effective method to remove commonly used solvents of varying polarities from aqueous waste streams. The resulting aqueous layers can potentially be sewered; whereas the organic layer can be recovered for potential reuse. Supercritical fluid extraction (SFE) is a technology that is increasingly being used in commercial processes (1). Supercritical fluids are well suited for extraction of a variety of media, including solids, natural products, and liquid products. Many supercritical fluids have low critical temperatures, allowing for extractions to be done at modestly low temperatures, thus avoiding any potential thermal decomposition of the solutes under study (2). Furthermore, the CO2 solvent strength is easily tuned by adjusting the density of the supercritical fluid (The density is proportional to the pressure of the extraction process). Since many supercritical fluids are gases at ambient temperature, the extract can be concentrated by simply venting the reaction mixture to a cyclone collection vessel, using appropriate safety protocols.
Preparticipation Screening of Athletic Officials: SEC Football Referees at Risk.
Turner, John L; Walters, Rod; Leski, Mark J; Saywell, Robert M; Wooldridge, J Scott
2003-03-01
Although preparticipation screening for athletes is commonplace, few studies have addressed the issue for those officiating at games. To review current data on physiologic stress on sports officials, to obtain prevalence data on health parameters for football officials, and to determine the outcomes when screening criteria are applied in preseason exams. A protocol was established using health history questionnaires and physical exams with laboratory screening to assess the health of all football officials working in the Southeastern Conference (SEC) from 1997 to 2000. The main outcome measure was the prevalence of cardiac risk factors as determined by American College of Sports Medicine guidelines. Initial screening of 102 football officials revealed that 10.1% of SEC referees had elevated systolic blood pressure, 13.9% had elevated diastolic blood pressure, and 3.8% had resting tachycardia. Average body mass index (BMI) was 28.6 kg/m2, with 87.3% having a BMI that exceeded 25 (overweight). About one-third (31.6%) had a BMI greater than 30 (obese). Total fasting cholesterol exceeded 200 mg/dL in 44.2%, HDL levels were below 35 mg/dL in 34.3%, and LDL levels were above 120 mg/dL in 62.3%. Compared with age-adjusted national data, there were more overweight and more obese officials, but they had lower systolic and diastolic blood pressures and lower mean total cholesterol levels. Using the Framingham Study prediction model to estimate coronary heart disease (CHD) risk, analysis revealed that referees had a lower risk than the national 10-year CHD risk but a higher risk compared with that of the low-risk population. These data reveal a greater need for graded exercise testing. The higher rates of obesity among officials will promote further screening for CHD risk factors.
Use of the proGAV shunt valve in normal-pressure hydrocephalus.
Toma, Ahmed K; Tarnaris, Andrew; Kitchen, Neil D; Watkins, Laurence D
2011-06-01
Overdrainage is a common complication associated with shunt insertion in normal-pressure hydrocephalus (NPH) patients. Using adjustable valves with antigravity devices has been shown to reduce its incidence. The optimal starting setting of an adjustable shunt valve in NPH is debatable. To audit our single-center practice of setting adjustable valves. We performed a retrospective review of clinical records of all NPH patients treated in our unit between 2006 and 2009 by the insertion of shunts with a proGAV valve, recording demographic and clinical data, shunt complications, and revision rates. Radiological reports of postoperative follow-up computed tomography scans of the brain were reviewed for detected subdural hematomas. A proGAV adjustable valve was inserted in 50 probable NPH patients between July 2006 and November 2009. Mean ± SD age was 76 ± 7 years. Mean follow-up was 15 months. The initial shunt setting was 6 ± 3 cm H2O, and the final setting was 4.9 ± 1.9 cm H2O. Nineteen patients required 24 readjustment procedures (readjustment rate, 38%; readjustment number, 0.48 times per patient). One patient (2%) developed delayed bilateral subdural hematoma after readjustment of his shunt valve setting as an outpatient. Starting with a low opening pressure setting on a proGAV adjustable shunt valve does not increase the chances of overdrainage complications and reduces the need for repeated readjustments.
Pfister, Roman; Michels, Guido; Sharp, Stephen J; Luben, Robert; Wareham, Nick J; Khaw, Kay-Tee
2014-04-01
Interventional trials provide evidence for a beneficial effect of reduced dietary sodium intake on blood pressure. The association of sodium intake with heart failure which is a long-term complication of hypertension has not been examined. Hazard ratios [HRs, 95% confidence interval (CI)] of heart failure comparing quintiles of estimated 24 h urinary sodium excretion (USE) were calculated in apparently healthy men (9017) and women (10,840) aged 39–79 participating in the EPIC study in Norfolk. During a mean follow-up of 12.9 years, 1210 incident cases of heart failure occurred. Compared with the reference category (128 mmol/day≤USE≤148 mmol/day), the top quintile (USE≥191 mmol/day) was associated with a significantly increased hazard of heart failure (1.32, 1.07–1.62) in multivariable analysis adjusting for age, sex, body mass index, diabetes, cholesterol, social class, educational level, smoking, physical activity, and alcohol consumption, with a marked attenuation (1.21, 0.98–1.49) when further adjusting for blood pressure. The bottom quintile (USE≤127 mmol/day) was also associated with an increased hazard of heart failure (1.29, 1.04–1.60) in multivariable analysis without relevant attenuation by blood pressure adjustment (1.26, 1.02–1.56), but with substantial attenuation when adjusting for interim ischaemic heart disease and baseline C-reactive protein levels and exclusion of events during the first 2 years (1.18, 0.96–1.47). We demonstrate a U-shaped association between USE and heart failure risk in an apparently healthy middle-aged population. The risk associated with the high range of USE was attenuated after adjustment for blood pressure, whereas the risk associated with the low range of USE was attenuated after adjustment for pre-existing disease processes. © 2014 The Authors. European Journal of Heart Failure © 2014 European Society of Cardiology.
Internal combustion engine cylinder-to-cylinder balancing with balanced air-fuel ratios
Harris, Ralph E.; Bourn, Gary D.; Smalley, Anthony J.
2006-01-03
A method of balancing combustion among cylinders of an internal combustion engine. For each cylinder, a normalized peak firing pressure is calculated as the ratio of its peak firing pressure to its combustion pressure. Each cylinder's normalized peak firing pressure is compared to a target value for normalized peak firing pressure. The fuel flow is adjusted to any cylinder whose normalized peak firing pressure is not substantially equal to the target value.
Serra, M; Pereiro, I; Yamada, A; Viovy, J-L; Descroix, S; Ferraro, D
2017-02-14
The sealing of microfluidic devices remains a complex and time-consuming process requiring specific equipment and protocols: a universal method is thus highly desirable. We propose here the use of a commercially available sealing tape as a robust, versatile, reversible solution, compatible with cell and molecular biology protocols, and requiring only the application of manually achievable pressures. The performance of the seal was tested with regards to the most commonly used chip materials. For most materials, the bonding resisted 5 bars at room temperature and 1 bar at 95 °C. This method should find numerous uses, ranging from fast prototyping in the laboratory to implementation in low technology environments or industrial production.
Gender Identity and Adjustment in Black, Hispanic, and White Preadolescents
ERIC Educational Resources Information Center
Corby, Brooke C.; Hodges, Ernest V. E.; Perry, David G.
2007-01-01
The generality of S. K. Egan and D. G. Perry's (2001) model of gender identity and adjustment was evaluated by examining associations between gender identity (felt gender typicality, felt gender contentedness, and felt pressure for gender conformity) and social adjustment in 863 White, Black, and Hispanic 5th graders (mean age = 11.1 years).…
ERIC Educational Resources Information Center
Searl, Jeff; Knollhoff, Stephanie; Barohn, Richard J.
2017-01-01
Purpose: This preliminary study on lingual-alveolar contact pressures (LACP) in people with amyotrophic lateral sclerosis (ALS) had several aims: (a) to evaluate whether the protocol induced fatigue, (b) to compare LACP during speech (LACP-Sp) and during maximum isometric pressing (LACP-Max) in people with ALS (PALS) versus healthy controls, (c)…
Response of the Cardiovascular System to Vibration and Combined Stresses
1975-08-31
Canines were chronically instrumented for continuous measurements of ascending aortic flow ( Zepeda ), left ventricular pressure (Konigsberg), circum- flex...different animals. Each dog was chronically instrumented for continuous measuremernt of ascending aortic flow ( Zepeda ), left ventricular pressure...vibration protocol as those animals restrained vertically. METHODS Canines (16 to 22 kg) were chronically instrumented with electromagnetic flow cuffs ( Zepeda
Using generalizability theory to develop clinical assessment protocols.
Preuss, Richard A
2013-04-01
Clinical assessment protocols must produce data that are reliable, with a clinically attainable minimal detectable change (MDC). In a reliability study, generalizability theory has 2 advantages over classical test theory. These advantages provide information that allows assessment protocols to be adjusted to match individual patient profiles. First, generalizability theory allows the user to simultaneously consider multiple sources of measurement error variance (facets). Second, it allows the user to generalize the findings of the main study across the different study facets and to recalculate the reliability and MDC based on different combinations of facet conditions. In doing so, clinical assessment protocols can be chosen based on minimizing the number of measures that must be taken to achieve a realistic MDC, using repeated measures to minimize the MDC, or simply based on the combination that best allows the clinician to monitor an individual patient's progress over a specified period of time.
Scalable Lunar Surface Networks and Adaptive Orbit Access
NASA Technical Reports Server (NTRS)
Wang, Xudong
2015-01-01
Teranovi Technologies, Inc., has developed innovative network architecture, protocols, and algorithms for both lunar surface and orbit access networks. A key component of the overall architecture is a medium access control (MAC) protocol that includes a novel mechanism of overlaying time division multiple access (TDMA) and carrier sense multiple access with collision avoidance (CSMA/CA), ensuring scalable throughput and quality of service. The new MAC protocol is compatible with legacy Institute of Electrical and Electronics Engineers (IEEE) 802.11 networks. Advanced features include efficiency power management, adaptive channel width adjustment, and error control capability. A hybrid routing protocol combines the advantages of ad hoc on-demand distance vector (AODV) routing and disruption/delay-tolerant network (DTN) routing. Performance is significantly better than AODV or DTN and will be particularly effective for wireless networks with intermittent links, such as lunar and planetary surface networks and orbit access networks.
Liu, Lilly Y; Feinglass, Joe M; Khan, Janine Y; Gerber, Susan E; Grobman, William A; Yee, Lynn M
2017-05-01
To evaluate adherence to a delayed cord clamping protocol for preterm births in the first 2 years after its introduction, perform a quality improvement assessment, and determine neonatal outcomes associated with protocol implementation and adherence. This is a retrospective cohort study of women delivering singleton neonates at 23-32 weeks of gestation in the 2 years before (preprotocol) and 2 years after (postprotocol) introduction of a 30-second delayed cord clamping protocol at a large-volume academic center. This policy was communicated to obstetric and pediatric health care providers and nurses and reinforced with intermittent educational reviews. Barriers to receiving delayed cord clamping were assessed using χ tests and multivariable logistic regression. Neonatal outcomes then were compared between all neonates in the preprotocol period and all neonates in the postprotocol period and between all neonates in the preprotocol period and neonates receiving delayed cord clamping in the postprotocol period using multivariable linear and logistic regression analyses. Of the 427 eligible neonates, 187 were born postprotocol. Of these, 53.5% (n=100) neonates received delayed cord clamping according to the protocol. The rate of delayed cord clamping preprotocol was 0%. Protocol uptake and frequency of delayed cord clamping increased over the 2 years after its introduction. In the postprotocol period, cesarean delivery was the only factor independently associated with failing to receive delayed cord clamping (adjusted odds ratio [OR] 0.49, 95% confidence interval [CI] 0.25-0.96). In comparison with the preprotocol period, those who received delayed cord clamping in the postprotocol period had significantly higher birth hematocrit (β=2.46, P=.007) and fewer blood transfusions in the first week of life (adjusted OR 0.49, 95% CI 0.25-0.96). After introduction of an institutional delayed cord clamping protocol followed by continued health care provider education and quality feedback, the frequency of delayed cord clamping progressively increased. Compared with historical controls, performing delayed cord clamping in eligible preterm neonates was associated with improved neonatal hematologic indices, demonstrating the effectiveness of delayed cord clamping in a large-volume maternity unit.
Samuelsson, Kersti; Björk, Maarit; Erdugan, Ann-Marie; Hansson, Anna-Karin; Rustner, Birgitta
2009-09-01
A wheelchair seat and position help clients perform daily activities. The comfort of the wheelchair can encourage clients to participate in daily activities and can help prevent future complications. This study evaluates how a shaped seat-cushion and two different back supports affect under-seat pressure, comfort, and pelvic rotation. Thirty healthy subjects were tested using two differently equipped manual wheelchairs. One wheelchair had a Velcro adjustable back seat and a plane seat-cushion. The other wheelchair had a non-adjustable sling-back seat and a plane cushion. The second wheelchair was also equipped with a shaped cushion and/or a detachable lumbar support. Under-seat pressure, estimated comfort, and pelvic rotation were measured after 10 min in each wheelchair outfit. Peak pressure increased with the shaped cushion compared to the plane cushion. No significant difference in estimated comfort was found. Pelvic posterior-rotation was reduced with the adjustable or detachable back-support irrespective of the shape of the seat cushion. To support a neutral pelvic position and spinal curvature, a combination of a shaped cushion and a marked lumbar support is most effective.
Karamat, Fares A; Horjus, Deborah L; Haan, Yentl C; van der Woude, Lisa; Oudman, Inge; van Montfrans, Gert A; Clark, Joseph F; Brewster, Lizzy M
2015-02-22
Despite adequate treatment, up to 30% of treated antihypertensive patients with primary, uncomplicated hypertension remain uncontrolled. We proposed that high intracellular activity of the ATP regenerating enzyme creatine kinase (CK) increases pressor responses and hypertension risk. In line with this, we found that plasma CK activity after rest, a surrogate measure of tissue activity, is the main predictor of blood pressure levels and failure of antihypertensive therapy in the general population. In addition, the creatine analog and competitive oral creatine kinase inhibitor beta-guanidinopropionic acid effectively and safely reduced blood pressure in the spontaneously hypertensive rat. However, to our knowledge there are no human data on the safety of oral supplementation with this substance. Therefore, we will assess the tolerability of beta-guanidinopropionic acid in men, compared to creatine and placebo. This is a randomized, active and placebo controlled, triple blind, double dummy, single center clinical intervention trial in 24 healthy male volunteers, 18 to 50 years old, recruited in the Netherlands. The intervention consists of one week of daily oral administration of beta-guanidinopropionic acid 100 mg, creatine 5 gram, or placebo. The primary outcome is the tolerability of beta-guanidinopropionic acid as a descriptive measure, in an intent-to-treat analysis. Other outcomes include the placebo-adjusted differences with baseline in biochemical and hemodynamic parameters, including plasma markers of muscle tissue damage, urine sodium excretion, resting sitting systolic and diastolic brachial blood pressure, supine systolic and diastolic central blood pressure, pulse wave velocity and augmentation index, heart rate, cardiac contractility, cardiac output, and total peripheral resistance. There is an unfulfilled need for new conservative options to treat resistant hypertension. This study will provide first-in-men data on creatine kinase inhibition as a potential new class of antihypertensive drugs. The Netherlands National Trial Register Trialregister.nl (identifier NTR 4444) , registered 9 March 2014.
Probabilistic direct counterfactual quantum communication
NASA Astrophysics Data System (ADS)
Zhang, Sheng
2017-02-01
It is striking that the quantum Zeno effect can be used to launch a direct counterfactual communication between two spatially separated parties, Alice and Bob. So far, existing protocols of this type only provide a deterministic counterfactual communication service. However, this counterfactuality should be payed at a price. Firstly, the transmission time is much longer than a classical transmission costs. Secondly, the chained-cycle structure makes them more sensitive to channel noises. Here, we extend the idea of counterfactual communication, and present a probabilistic-counterfactual quantum communication protocol, which is proved to have advantages over the deterministic ones. Moreover, the presented protocol could evolve to a deterministic one solely by adjusting the parameters of the beam splitters. Project supported by the National Natural Science Foundation of China (Grant No. 61300203).
Protocol dependence of mechanical properties in granular systems.
Inagaki, S; Otsuki, M; Sasa, S
2011-11-01
We study the protocol dependence of the mechanical properties of granular media by means of computer simulations. We control a protocol of realizing disk packings in a systematic manner. In 2D, by keeping material properties of the constituents identical, we carry out compaction with various strain rates. The disk packings exhibit the strain rate dependence of the critical packing fraction above which the pressure becomes non-zero. The observed behavior contrasts with the well-studied jamming transitions for frictionless disk packings. We also observe that the elastic moduli of the disk packings depend on the strain rate logarithmically. Our results suggest that there exists a time-dependent state variable to describe macroscopic material properties of disk packings, which depend on its protocol.
Moy, Foong-Ming; Bulgiba, Awang
2011-09-27
Vitamin D status, as indicated by 25-hydroxyvitamin D is inversely associated with adiposity, glucose homeostasis, lipid profiles, and blood pressure along with its classic role in calcium homeostasis and bone metabolism. It is also shown to be inversely associated with metabolic syndrome and cardiovascular diseases in western populations. However, evidence from the Asian population is limited. Therefore, we aim to study the prevalence of vitamin D insufficiency (< 50 nmol/L) and the association of 25-hydroxyvitamin D with metabolic risk factors among an existing Malay cohort in Kuala Lumpur. This is an analytical cross sectional study. A total of 380 subjects were sampled and their vitamins D status (25-hydroxyvitamin D), fasting blood glucose, full lipid profile were assessed using venous blood. Systolic and diastolic blood pressure, weight, height and waist circumference were measured following standard protocols. Socio-demographic data such as sex, age, smoking status etc were also collected. Data was analysed using t-test, chi-square test, General Linear Model and multiple logistic regression. Females made up 58% of the sample. The mean age of respondents was 48.5 (SD 5.2) years. Females had significantly lower mean Vitamin D levels (36.2; 95% CI: 34.5, 38.0 nmol/L) compared to males (56.2; 95% CI: 53.2, 59.2 nmol/L). Approximately 41% and 87% of males and females respectively had insufficient (< 50 nmol/L) levels of 25-hydroxyvitamin D (p < 0.001). The prevalence of Metabolic Syndrome for the whole sample was 38.4 (95% CI: 33.5, 43.3)%. In the multivariate model (adjusted for age, sex, abdominal obesity, HDL-cholesterol, diastolic blood pressure), insufficient Vitamin D status was significantly associated with 1-year age increments (OR: 0.93; 95% CI: 0.88, 0.98), being female (OR: 8.68; 95% CI: 5.08, 14.83) and abdominal obesity (OR: 2.57; 95% CI: 1.51, 4.39). Respondents with insufficient vitamin D were found to have higher odds of having Metabolic Syndrome (OR: 1.73; 95% CI: 1.02, 2.92) after adjusting for age and sex. Our results highlight the high prevalence of vitamin D insufficiency among Malay adults in Kuala Lumpur. Vitamin D insufficiency is independently associated with younger age, female sex and greater abdominal obesity. Vitamin D insufficiency is also associated with Metabolic Syndrome.
Comparison between two physiotherapy protocols for patients with chronic kidney disease on dialysis
Neto, José Roberto Sostena; Figueiredo e Castro, Letícia Magalhães; Santos de Oliveira, Fernanda; Silva, Andréia Maria; Maria dos Reis, Luciana; Quirino, Ana Paula Assunção; Dragosavac, Desanka; Kosour, Carolina
2016-01-01
[Purpose] To compare the effects of two physiotherapy protocols for chronic kidney disease patients on dialysis. [Subjects and Methods] This is a prospective, randomized study, in chronic kidney disease patients 18 years of age or older on dialysis. Sessions for each group (were conducted three times per week for a total of 10 sessions), during hemodialysis. Respiratory muscle strength (maximal inspiratory and expiratory pressure), peak expiratory flow, and peripheral muscle strength were evaluated. The study group received motor and respiratory physiotherapy, and the control group received motor physiotherapy alone. [Results] We observed a significant increase in the maximal inspiratory pressure in the study group in the 5th and 10th sessions and in the maximal expiratory pressure in the 1st session, peak flow in the 1st and 10th sessions, and dynamometry in the 10th session. In the control group, there was a significant decrease in maximal inspiratory pressure in the 5th and 10th sessions, and in maximal expiratory pressure in the 10th session, peak flow in the 5th and 10th sessions, and dynamometry in the 5th session. [Conclusion] Implementation of motor physiotherapy combined with respiratory physiotherapy may have contributed to the improvement of the variables analyzed in the study group. PMID:27313390
A validation of the Mobil O Graph (version 12) ambulatory blood pressure monitor.
Jones, C R; Taylor, K; Chowienczyk, P; Poston, L; Shennan, A H
2000-08-01
To assess the clinical accuracy of the Mobil O Graph (version 12) ambulatory blood pressure monitor in an adult population. The accuracy of the device was assessed by predefined criteria (British Hypertension Society, BHS) in 85 subjects recruited from the patients and staff in a teaching hospital. A series of same-arm sequential blood pressure measurements were taken: first two observers taking simultaneous mercury readings, followed by a reading with the Mobil O Graph ambulatory monitor. A total of seven readings were taken from each subject in the sitting position. The data were then analysed according to the BHS protocol and the criteria of the Association for the Advancement of Medical Instrumentation (AAMI). The Mobil O Graph ambulatory monitor fulfilled the criteria of the BHS protocol, achieving a grade B for systolic blood pressure (SBP) and a grade A for diastolic blood pressure (DBP). The mean differences were -2+/-8 mmHg for SBP and -2+/-7 mmHg for DBP. The device therefore also passed the AAMI standard (the mean to be within 5+/-8 mmHg). The Mobil O Graph ambulatory monitor performed in a satisfactory manner according to the BHS and the AAMI criteria and can therefore be recommended for clinical use in the general population.
JPRS Report, Near East & South Asia India.
1992-11-12
Pressure [THE HINDU 25 Oct] 19 ECONOMIC Frontier With China Slated for Opening to Tourism [TIMES OF INDIA 19 Oct] 21 Trade Protocol With CIS...extensive promotion of bilateral trade , develop- ment of civil project cooperation and consolidation of defence cooperation with adequate financing. It...three million tonnes of crude next year. Also, Indian exports to Russia outside the 1992 trade protocol registered $471 millions in the first six
Hydroxylapatite chromatography.
Broadhurst, A V
2001-05-01
Hydroxylapatite (also called hydroxyapatite), a form of calcium phosphate, can be used as a matrix for the chromatography of both proteins and nucleic acids. Protocols are provided for both standard low-pressure chromatography of a protein mixture using a hydroxylapatite column prepared in the laboratory, and an HPLC method, applicable to proteins and nucleic acids, that uses a commercially available column. Alternate protocols describe column chromatography using a step gradient or batch binding and step-gradient elution.
Chung, Charles S; Granzier, Henk L
2011-01-01
It remains to be established to what degree titin and the extracellular matrix (ECM) contribute to passive pressure in the left ventricle (LV). Thus, we aimed to elucidate the contribution of major molecular determinants of passive pressure in the normal mouse LV. Furthermore, we determined the working sarcomere length (SL) range of the LV to bridge our findings to earlier work in skinned muscle fibers. We utilized Frank-Starling type protocols to obtain diastolic pressure-volume relationships (PVR) in Langendorff perfused isolated LVs. To quantify the molecular contribution of titin and ECM, we innovated on methods of fiber mechanics to chemically permeabilize intact LVs and measure a fully passive PVR. To differentially dissect the contributions of the ECM and titin, we utilized myofilament extraction techniques in permeabilized LVs, measuring passive PVRs at each stage in the protocol. Myofilament extraction suggests that titin contributes ~80% of passive pressures in the heart. Langendorff perfusion was also used to chemically fix passive and BaCl2 activated hearts at specific volumes to determine that the maximal working SL range of the midwall LV fibers is approximately 1.8-2.2 μm. A model of the passive SL-Volume relationship was then used to estimate the pressure-SL relationships, indicating that the ECM contribution does not exceed titin's contribution until large volumes with SLs>~2.2μm. In conclusion, within physiological volumes titin is the dominant contributor to LV passive pressure, and ECM-based pressures dominates at larger volumes. PMID:21255582
Woc Colburn, A Margarita; Murray, Suzan; Hayek, Lee-Ann C; Marker, Laurie; Sanchez, Carlos R
2017-03-01
Multiple anesthesia protocols have been used in the cheetah ( Acinonyx jubatus ). Twenty healthy, captive cheetahs were immobilized with dexmedetomidine (15.8 ± 1.9 μg/kg), butorphanol (0.22 ± 0.03 mg/kg), and midazolam (0.18 ± 0.03 mg/kg) by intramuscular injection. Induction, recumbency, and recovery times were recorded, and physiologic parameters were monitored. Anesthesia was antagonized with atipamezole (0.125 ± 0.02 mg/kg) and naltrexone (0.1 ± 0.014 mg/kg) intramuscularly. All cheetahs were safely anesthetized with this protocol. Cheetahs were laterally recumbent by 8 ± 3.5 min. Cardiorespiratory values were stable throughout the length of anesthesia. Moderate hypertension, with systolic blood pressure ranging from 178 ± 19.8 mm Hg, was initially observed but decreased over time. There was a statistical decreasing trend in temperature; SpO2; and systolic, mean, and diastolic blood pressure, but not in heart rate and end-tidal CO 2 . Recoveries were rapid, with cheetahs standing by 11.3 ± 5.7 min postreversal administration. This is the first report of a dexmedetomidine-butorphanol-midazolam anesthetic combination in cheetahs. Overall, this anesthetic protocol proved to be safe and effective.
Ecological quality boundary-setting procedures: the Gulf of Riga case study.
Aigars, Juris; Müller-Karulis, Bärbel; Martin, Georg; Jermakovs, Vadims
2008-03-01
Two approaches for setting ecological class boundaries, response curves and a simplified mathematical boundary-setting protocol, were tested for coastal, transitional and open waters in the Gulf of Riga, Baltic Sea. The simplified mathematical boundary-setting protocol defines acceptable ecological status based on expert judgment by a uniform relative deviation from reference conditions. In contrast, response curves derive class boundary definitions from observed changes in biological quality elements along environmental pressure gradients for class boundary definitions. Identification of relevant environmental pressures for the construction of response curves was based on a conceptual model of eutrophication in the Gulf of Riga. Response curves were successfully established for summer chlorophyll a and transparency, as well as for macrozoobenthos abundance in the Central Gulf, macrozoobenthos biotic coefficient in the Southern Gulf, and maximum depth of phytobenthos in the Northern Gulf. In the Gulf of Riga response curves almost always permitted a larger deviation from reference conditions than the 50% deviation applied for the simplified mathematical boundary-setting protocol. The case study clearly demonstrated that class boundary definitions should take into account the sensitivity of the target water body. Also, the class boundaries for different ecological quality elements were internally more consistent than those derived by the simplified mathematical boundary-setting protocol.
Buldt, Andrew K; Allan, Jamie J; Landorf, Karl B; Menz, Hylton B
2018-02-23
Foot posture is a risk factor for some lower limb injuries, however the underlying mechanism is not well understood. Plantar pressure analysis is one technique to investigate the interaction between foot posture and biomechanical function of the lower limb. The aim of this review was to investigate the relationship between foot posture and plantar pressure during walking. A systematic database search was conducted using MEDLINE, CINAHL, SPORTDiscus and Embase to identify studies that have assessed the relationship between foot posture and plantar pressure during walking. Included studies were assessed for methodological quality. Meta-analysis was not conducted due to heterogeneity between studies. Inconsistencies included foot posture classification techniques, gait analysis protocols, selection of plantar pressure parameters and statistical analysis approaches. Of the 4213 citations identified for title and abstract review, sixteen studies were included and underwent quality assessment; all were of moderate methodological quality. There was some evidence that planus feet display higher peak pressure, pressure-time integral, maximum force, force-time integral and contact area predominantly in the medial arch, central forefoot and hallux, while these variables are lower in the lateral and medial forefoot. In contrast, cavus feet display higher peak pressure and pressure-time integral in the heel and lateral forefoot, while pressure-time integral, maximum force, force-time integral and contact area are lower for the midfoot and hallux. Centre of pressure was more laterally deviated in cavus feet and more medially deviated in planus feet. Overall, effect sizes were moderate, but regression models could only explain a small amount of variance in plantar pressure variables. Despite these significant findings, future research would benefit from greater methodological rigour, particularly in relation to the use of valid foot posture measurement techniques, gait analysis protocols, and standardised approaches for analysis and reporting of plantar pressure variables. Copyright © 2018 Elsevier B.V. All rights reserved.
Zamani, Nader; Sharath, Sherene E; Vo, Elaine; Awad, Samir S; Kougias, Panos; Barshes, Neal R
2018-01-01
Wound complications remain a significant source of morbidity for patients undergoing open infra-inguinal re-vascularization. The purpose of this study was to determine the impact of several infection-control strategies on post-operative wound complications after open infra-inguinal re-vascularization. A retrospective cohort study was conducted among all patients who underwent an open infra-inguinal re-vascularization procedure before and after 2014. Since 2014, we have implemented strategies to reduce post-operative wound complications, including: (1) Decreasing the use of incisional skin staples, (2) increasing the use of negative pressure wound therapy (NPWT) dressings, and (3) implementing an outpatient elective decontamination protocol for methicillin-resistant Staphylococcus aureus. "Pre-era" is defined as the period between January 2012 and December 2013, before the implementation of infection control strategies; "Post-era" is between January 2015 and August 2016, after implementation. The primary outcome of interest is 30-day wound complications (infection or dehiscence). Multi-variable logistic regression analysis was used to identify significant predictors of wound-related complications between the two cohorts. Propensity score adjustment controlled for baseline patient characteristics, peri-operative variables, and surgeon experience. A total of 338 open infra-inguinal procedures were performed: 175 in the pre-era and 163 in the post-era. Chlorhexidine skin preparation was used in the majority (321 [95%]) of cases. Comparing the periods, the post-era is characterized by a significant decrease in the use of groin staples (118 [67%] vs. 51 [31%], p < 0.001), and an increased application of NPWT dressings (6 [4%] vs. 66 [43%], p < 0.001). Thirty-five (37%) outpatient elective cases received the pre-operative decontamination protocol in the post-era. Compared with the pre-era, there was a decrease in the 30-day rate of wound complications (68 [39%] to 42 [26%], p = 0.011), and infection-related re-admissions (31 [17.7%] to 21 [12.9%], p = 0.220). When adjusting for patient characteristics, operative variables, and surgeon experience, post-era had significantly lower wound complications (odds ratio [OR] 0.33, p = 0.002) and re-operations (OR 0.16, p = 0.007). Among outpatient elective cases, the decontamination protocol was also independently associated with these two outcomes (wound complications: OR 0.05, p = 0.006; re-operations: 0.06, p = 0.002). The use of groin staples was an independent predictor of deep groin infections (OR 248, p < 0.001) and re-operations (OR 8.16, p = 0.032). Wound complications after open infra-inguinal re-vascularization have decreased significantly after the implementation of several infection-control strategies. Findings suggest that skin staples should be avoided in groin wounds, and anti-staphylococcal decontamination protocols decrease wound complications and prevent re-operations.
Development of a 30mm Frangible Projectile Crimper
1977-02-01
located at end of tank. Open drain valve to drain condensation Tht outomatic lank drain equipped compressor makes this unnecessary. PRESSURE SWITCH : The... pressure switch is automatic and will start compressor at the low pressure and stop when the maximum pressure is leached. It is adjusted to start...of the check valve, located between the compressor and the tank, together with the relief valve on pressure switch relief valve units, and the cen
Lessons Learned From Developing Reactor Pressure Vessel Steel Embrittlement Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John
Materials behaviors caused by neutron irradiation under fission and/or fusion environments can be little understood without practical examination. Easily accessible material information system with large material database using effective computers is necessary for design of nuclear materials and analyses or simulations of the phenomena. The developed Embrittlement Data Base (EDB) at ORNL is this comprehensive collection of data. EDB database contains power reactor pressure vessel surveillance data, the material test reactor data, foreign reactor data (through bilateral agreements authorized by NRC), and the fracture toughness data. The lessons learned from building EDB program and the associated database management activity regardingmore » Material Database Design Methodology, Architecture and the Embedded QA Protocol are described in this report. The development of IAEA International Database on Reactor Pressure Vessel Materials (IDRPVM) and the comparison of EDB database and IAEA IDRPVM database are provided in the report. The recommended database QA protocol and database infrastructure are also stated in the report.« less
Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S
2015-04-01
Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.
Socioeconomic disadvantage and change in blood pressure associated with aging.
Diez Roux, Ana V; Chambless, Lloyd; Merkin, Sharon Stein; Arnett, Donna; Eigenbrodt, Marsha; Nieto, F Javier; Szklo, Moyses; Sorlie, Paul
2002-08-06
Few studies have examined how the longitudinal change in blood pressure associated with aging differs across social groups within industrialized countries. Data from the Atherosclerosis Risk In Communities Study were used to investigate differences in the incidence of hypertension and in aging-related changes in blood pressure by neighborhood and individual socioeconomic factors over a 9-year follow-up. Disadvantage in multiple socioeconomic dimensions was associated with the greatest risk of developing hypertension (age- and sex-adjusted hazard ratio [HR] and 95% CI: HR 1.95, 95% CI 1.38 to 2.75 in whites and HR 1.43, 95% CI 0.96 to 2.13 in blacks). Aging-related increases in systolic blood pressure were inversely associated with socioeconomic position in whites (mean [SEM] 5-year increase in systolic blood pressure 7 [0.7] mm Hg in the most disadvantaged category and 5.4 [0.4] mm Hg in the most advantaged category). In whites, low socioeconomic position was also associated with more rapid declines in diastolic blood pressure after 50 years of age. Socioeconomic differences in hypertension incidence and changes in systolic blood pressure were reduced after adjustment for baseline blood pressure. The change in blood pressure associated with aging varies by social groups within the United States.
Protocolized fluid therapy in brain-dead donors: the multicenter randomized MOnIToR trial.
Al-Khafaji, Ali; Elder, Michele; Lebovitz, Daniel J; Murugan, Raghavan; Souter, Michael; Stuart, Susan; Wahed, Abdus S; Keebler, Ben; Dils, Dorrie; Mitchell, Stephanie; Shutterly, Kurt; Wilkerson, Dawn; Pearse, Rupert; Kellum, John A
2015-03-01
Critical shortages of organs for transplantation jeopardize many lives. Observational data suggest that better fluid management for deceased organ donors could increase organ recovery. We conducted the first large multicenter randomized trial in brain-dead donors to determine whether protocolized fluid therapy increases the number of organs transplanted. We randomly assigned donors to either protocolized or usual care in eight organ procurement organizations. A "protocol-guided fluid therapy" algorithm targeting the cardiac index, mean arterial pressure and pulse pressure variation was used. Our primary outcome was the number of organs transplanted per donor, and our primary analysis was intention to treat. Secondary analyses included: (1) modified intention to treat where only subjects able to receive the intervention were included and (2) 12-month survival in transplant recipients. The study was stopped early. We enrolled 556 donors: 279 protocolized care and 277 usual care. Groups had similar characteristics at baseline. The study protocol could be implemented in 76 % of subjects randomized to the intervention. There was no significant difference in mean number of organs transplanted per donor: 3.39 organs per donor (95 % CI 3.14-3.63) with protocolized care compared to 3.29 usual care (95 % CI 3.04-3.54; mean difference, 0.1, 95 % CI -0.25 to 0.45; p = 0.56). In modified intention-to-treat analysis the mean number of organs increased (3.52 organs per donor, 95 % CI 3.23-3.8), but not statistically significantly (mean difference, 0.23, 95 % CI -0.15 to 0.61; p = 0.23). Among the 1,430 recipients of organs from study subjects with data available, 56 deaths (7.8 %) occurred in the protocolized care arm and 56 (7.9 %) in the usual care arm in the first year (hazard ratio: 0.97, p = 0.86). In brain-dead organ donors, protocol-guided fluid therapy compared to usual care may not increase the number of organs transplanted per donor.
An alternative to reduction of surface pressure to sea level
NASA Technical Reports Server (NTRS)
Deardorff, J. W.
1982-01-01
The pitfalls of the present method of reducing surface pressure to sea level are reviewed, and an alternative, adjusted pressure, P, is proposed. P is obtained from solution of a Poisson equation over a continental region, using the simplest boundary condition along the perimeter or coastline where P equals the sea level pressure. The use of P would avoid the empiricisms and disadvantages of pressure reduction to sea level, and would produce surface pressure charts which depict the true geostrophic wind at the surface.
Zeng, Wei-Fang; Kang, Yuan-Yuan; Liu, Ming; Li, Yan; Wang, Ji-Guang
2013-06-01
The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor A&D UA-1020 with two different-shaped cuffs for home BP monitoring according to the British Hypertension Society (BHS) Protocol. We recruited individuals for each of the two cuffs (D-ring and cylindrical) until there were 85 eligible participants (255 pairs of comparisons) and their BP could meet the BP distribution requirements specified by the BHS Protocol. For each participant, we sequentially measured the systolic and diastolic BP using a mercury sphygmomanometer (two observers) and the UA-1020 device (one supervisor). For the D-ring cuff, the device achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 87, and 96%, respectively, for systolic BP, and 70, 90, and 99%, respectively, for diastolic BP. The average (±SD) of the device-observer differences was -0.2±7.3 mmHg (P=0.64) and 1.7±5.8 mmHg (P<0.0001) for systolic and diastolic BP, respectively. For the cylindrical cuff, the device also achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 88, and 97%, respectively, for systolic BP and 64, 89, and 98%, respectively, for diastolic BP. The average of the device-observer differences was -0.1±7.0 mmHg (P=0.89) and 2.0±6.3 mmHg (P<0.0001) for systolic and diastolic BP, respectively. The UA-1020 device has passed the requirements of the BHS Protocol with both the D-ring and the cylindrical cuffs, and hence can be recommended for home use in adults.
Vallejos, Augusto; Alperovich, Gabriela; Moreso, Francesc; Cañas, Concepcion; de Lama, M Eugenia; Gomà, Montserrat; Fulladosa, Xavier; Carrera, Marta; Hueso, Miguel; Grinyó, Josep M; Serón, Daniel
2005-11-01
The presence of chronic allograft nephropathy (CAN) in protocol biopsies is negatively associated with graft survival. Although recent studies have indicated that the resistive index (RI) is a predictor of graft failure, it does not correlate with CAN in stable grafts. We therefore studied the relationship between RI and CAN and examined the predictive value of both parameters on graft outcome. Included were patients transplanted between 1997 and 2002 and who had protocol biopsies and RI determinations. Renal lesions were blindly evaluated according to Banff 97 criteria. Mean glomerular volume, cortical interstitial volume fraction and intimal arterial volume fraction were estimated using a point counting technique. RI was determined before biopsy in at least two different renal locations. The outcome variable was defined as graft failure or a 30% serum creatinine increase between protocol biopsy and last follow-up. Eighty-seven patients were included. RI correlated with recipient age (R = 0.52, P < 0.0001), diastolic blood pressure (R = -0.36, P = 0.0006), pulse pressure index (R = 0.27, P = 0.009) and g-score for histological glomerulitis (rho = 0.30, P = 0.0054), but there were no correlations between RI and chronic Banff scores or any morphometric parameter. The presence of CAN (relative risk, 3.5; 95% confidence interval 1.2-10.2; P = 0.02) but not RI was associated with the outcome variable. RI was associated with surrogate measures of vascular compliance such as recipient age and pulse pressure index but not with chronic allograft damage, even when it was evaluated by histomorphometry. Our results indicate that histology may be superior to RI in predicting graft function deterioration, at least in patients with stable renal function.
NASA Astrophysics Data System (ADS)
Livshts, Mikhail A.; Khomyakova, Elena; Evtushenko, Evgeniy G.; Lazarev, Vassili N.; Kulemin, Nikolay A.; Semina, Svetlana E.; Generozov, Edward V.; Govorun, Vadim M.
2015-11-01
Exosomes, small (40-100 nm) extracellular membranous vesicles, attract enormous research interest because they are carriers of disease markers and a prospective delivery system for therapeutic agents. Differential centrifugation, the prevalent method of exosome isolation, frequently produces dissimilar and improper results because of the faulty practice of using a common centrifugation protocol with different rotors. Moreover, as recommended by suppliers, adjusting the centrifugation duration according to rotor K-factors does not work for “fixed-angle” rotors. For both types of rotors - “swinging bucket” and “fixed-angle” - we express the theoretically expected proportion of pelleted vesicles of a given size and the “cut-off” size of completely sedimented vesicles as dependent on the centrifugation force and duration and the sedimentation path-lengths. The proper centrifugation conditions can be selected using relatively simple theoretical estimates of the “cut-off” sizes of vesicles. Experimental verification on exosomes isolated from HT29 cell culture supernatant confirmed the main theoretical statements. Measured by the nanoparticle tracking analysis (NTA) technique, the concentration and size distribution of the vesicles after centrifugation agree with those theoretically expected. To simplify this “cut-off”-size-based adjustment of centrifugation protocol for any rotor, we developed a web-calculator.
Reduced Lung Cancer Mortality With Lower Atmospheric Pressure.
Merrill, Ray M; Frutos, Aaron
2018-01-01
Research has shown that higher altitude is associated with lower risk of lung cancer and improved survival among patients. The current study assessed the influence of county-level atmospheric pressure (a measure reflecting both altitude and temperature) on age-adjusted lung cancer mortality rates in the contiguous United States, with 2 forms of spatial regression. Ordinary least squares regression and geographically weighted regression models were used to evaluate the impact of climate and other selected variables on lung cancer mortality, based on 2974 counties. Atmospheric pressure was significantly positively associated with lung cancer mortality, after controlling for sunlight, precipitation, PM2.5 (µg/m 3 ), current smoker, and other selected variables. Positive county-level β coefficient estimates ( P < .05) for atmospheric pressure were observed throughout the United States, higher in the eastern half of the country. The spatial regression models showed that atmospheric pressure is positively associated with age-adjusted lung cancer mortality rates, after controlling for other selected variables.
A Simple Membrane Osmometer System & Experiments that Quantitatively Measure Osmotic Pressure
ERIC Educational Resources Information Center
Marvel, Stephen C.; Kepler, Megan V.
2009-01-01
It is important for students to be exposed to the concept of osmotic pressure. Understanding this concept lays the foundation for deeper discussions that lead to more theoretical aspects of water movement associated with the concepts of free energy, water potential, osmotic potential, pressure potential, and osmotic adjustment. The concept of…
Sandset, Else Charlotte; Sanossian, Nerses; Woodhouse, Lisa J; Anderson, Craig; Berge, Eivind; Lees, Kennedy R; Potter, John F; Robinson, Thompson G; Sprigg, Nikola; Wardlaw, Joanna M; Bath, Philip M
2018-01-01
Rationale Despite several large clinical trials assessing blood pressure lowering in acute stroke, equipoise remains particularly for ischemic stroke. The "Blood pressure in Acute Stroke Collaboration" commenced in the mid-1990s focussing on systematic reviews and meta-analysis of blood pressure lowering in acute stroke. From the start, Blood pressure in Acute Stroke Collaboration planned to assess safety and efficacy of blood pressure lowering in acute stroke using individual patient data. Aims To determine the optimal management of blood pressure in patients with acute stroke, including both intracerebral hemorrhage and ischemic stroke. Secondary aims are to assess which clinical and therapeutic factors may alter the optimal management of high blood pressure in patients with acute stroke and to assess the effect of vasoactive treatments on hemodynamic variables. Methods and design Individual patient data from randomized controlled trials of blood pressure management in participants with ischemic stroke and/or intracerebral hemorrhage enrolled during the ultra-acute (pre-hospital), hyper-acute (<6 h), acute (<48 h), and sub-acute (<168 h) phases of stroke. Study outcomes The primary effect variable will be functional outcome defined by the ordinal distribution of the modified Rankin Scale; analyses will also be carried out in pre-specified subgroups to assess the modifying effects of stroke-related and pre-stroke patient characteristics. Key secondary variables will include clinical, hemodynamic and neuroradiological variables; safety variables will comprise death and serious adverse events. Discussion Study questions will be addressed in stages, according to the protocol, before integrating these into a final overreaching analysis. We invite eligible trials to join the collaboration.
Johnson, Davin; Winterborn, Andrew; Kratky, Vladimir
2016-01-01
To report the efficacy of intravenous mannitol in the treatment of orbital compartment syndrome. An experimental study was conducted on 4 nonhuman primates (8 orbits). Orbital compartment syndrome was simulated by injecting autologous blood into both orbits of each nonhuman primate until a pressure of 80 mm Hg was reached (time 0). After 10 minutes, nonhuman primates were randomized to receive an infusion of either mannitol or saline, given over 15 minutes. Five minutes after the infusion was complete, lateral canthotomy and cantholysis was performed on both orbits in isolated steps every 5 minutes. During the study protocol, orbital and intraocular pressures were recorded every 5 minutes, with a final set of measurements at 60 minutes. The primary outcome measures were the mean change in pressure from time 0 to 60 minutes, as well as the mean change in pressure during the infusion period. There was no statistically significant difference in the mean changes in orbital or intraocular pressure from time 0 to 60 minutes of the protocol. However, during the infusion period there was significantly greater decrease in both orbital and intraocular pressure in the mannitol compared with saline group (-34.0 vs. -9.3 mm Hg for orbital pressure [p = 0.03]; -34.8 vs. -9.7 mm Hg for intraocular pressure [p = 0.04]). While the definitive treatment of orbital compartment syndrome is lateral canthotomy and cantholysis, mannitol results in a rapid and clinically meaningful drop in orbital and intraocular pressure. The authors believe that their data support the routine use of mannitol in orbital compartment syndrome, especially when there is a delay in timely surgical management.
Makiyama, Kiyoshi; Yoshihashi, Hidetaka; Mogitate, Manabu; Kida, Akinori
2005-04-01
To determine the role of the adjustment of expiratory effort in the control of vocal intensity. An intensity-loading test was performed by using the airway interruption method. Three groups of subjects were used: a control group thought to resemble normal vocal fold closure, a group of patients with Reinke's edema thought to represent increased mass at the level of the vocal folds, and a group with vocal fold paralysis that was thought to represent a group with lack of adequate vocal fold closure. In the control group, expiratory lung pressure and airway resistance slightly increased. In the patients with Reinke's edema, expiratory lung pressure, and airway resistance significantly increased. In this group, the voice intensity was controlled by laryngeal adjustment, but a greater expiratory effort was needed because of a greater increase in glottal resistance. In the patients with vocal cord paralysis, airway resistance did not increase even with a high-intensity voice. Vocal intensity was controlled by expiratory effort. If there is sufficient ability for laryngeal adjustment, vocal intensity is controlled primarily by laryngeal adjustment and by expiratory adjustment in response to increased glottal resistance. However, vocal intensity is controlled by expiratory effort when laryngeal adjustment ability is poor.
Cardiorespiratory effects of water ingestion during and after exercise
2013-01-01
Background In prolonged exercise, the state of hypohydration due to sweating raises physiological stress and induces a drop in sports performance. However, the impact of water intake in cardiorespiratory parameters when administered during and after physical activity has not been well studied. This study aimed to analyze the effects of water intake in heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), partial oxygen saturation (SpO2) and respiratory rate during and after prolonged exercise. Methods Thirty-one young males (21.55 ± 1.89 yr) performed three different protocols (48 h interval between each stage): I) maximal exercise test to determine the load for the protocols; II) Control protocol (CP) and; III) Experimental protocol (EP). The protocols consisted of 10 min at rest with the subject in the supine position, 90 min of treadmill exercise (60% of VO2 peak) and 60 min of rest placed in the dorsal decubitus position. No rehydration beverage consumption was allowed during CP. During EP, however, the subjects were given water (Vittalev, Spaipa, Brazil). The parameters HR, SBP, DBP, SpO2 and respiratory rate were measured at the end of the rest, in 30, 60 and 90 minutes of the activity, except the respiratory rate parameter, and at 1, 3, 5, 7, 10, 20, 30, 40, 50 and 60 minute post- exercise. Results The hydration protocol provided minimal changes in SBP and DBP and a smaller increase in HR and did not significantly affect SpO2 during exercise and better HR recovery, faster return of SBP and DBP and a better performance for SpO2 and respiratory rate post-exercise. Conclusion Hydration with water influenced the behavior of cardiorespiratory parameters in healthy young subjects. PMID:24059759
NASA Technical Reports Server (NTRS)
Ashby, George C., Jr.; Robbins, W. Eugene; Horsley, Lewis A.
1991-01-01
Probe readily positionable in core of uniform flow in hypersonic wind tunnel. Formed of pair of mating cylindrical housings: transducer housing and pitot-tube housing. Pitot tube supported by adjustable wedge fairing attached to top of pitot-tube housing with semicircular foot. Probe adjusted both radially and circumferentially. In addition, pressure-sensing transducer cooled internally by water or other cooling fluid passing through annulus of cooling system.
Nizar, Jonathan M; Bouby, Nadine; Bankir, Lise; Bhalla, Vivek
2018-06-01
Many experimental protocols in rodents require the comparison of groups that are fed different diets. Changes in dietary electrolyte and/or fat content can influence food intake, which can potentially introduce bias or confound the results. Unpalatable diets slow growth or cause weight loss, which is exacerbated by housing the animals in individual metabolic cages or by surgery. For balance studies in mice, small changes in body weight and food intake and low urinary flow can amplify these challenges. Powder food can be administered as gel with the addition of a desired amount of water, electrolytes, drugs (if any), and a small amount of agar. We describe here how the use of gel food to vary water, Na, K, and fat content can reduce weight loss and improve reproducibility of intake, urinary excretion, and blood pressure in rodents. In addition, mild food restriction reduces the interindividual variability and intergroup differences in food intake and associated variables, thus improving the statistical power of an experiment. Finally, we also demonstrate the advantages of using gel food for weight-based drug dosing. These protocols can improve the accuracy and reproducibility of experimental data where dietary manipulations are needed and are especially advisable in rodent studies related to water balance, obesity, and blood pressure.
Wu, Ning; Zhang, Xuezhong; Wang, Wen; Zhang, Hongye
2016-10-01
This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor Andon KD5031 for home BP monitoring according to the European Society of Hypertension International Protocol revision 2010. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were sequentially measured in 33 participants using the standard mercury sphygmomanometer and the Andon KD5031 device. Ninety-nine pairs of comparisons were obtained from 33 participants for analysis. The KD5031 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and the observers within a range of 5, 10, and 15 mmHg was 66/99, 93/99, and 98/99, respectively, for SBP and 72/99, 94/99, and 99/99, respectively, for DBP. The device also achieved the targets in part 2 of the validation study. Twenty-six participants for both SBP and DBP had at least two of the three device-observer differences within 5 mmHg (required ≥24). The number of participants without a device-observer difference within 5 mmHg was one for SBP and three for DBP (required ≤3). The Andon upper arm BP monitor KD5031 has passed the International Protocol requirements, and it can be recommended for clinical use and self-measurement in adults.
Evaluation of a Progressive Mobility Protocol in Postoperative Cardiothoracic Surgical Patients.
Floyd, Shawn; Craig, Sarah W; Topley, Darla; Tullmann, Dorothy
2016-01-01
Cardiothoracic surgical patients are at high risk for complications related to immobility, such as increased intensive care and hospital length of stay, intensive care unit readmission, pressure ulcer development, and deep vein thrombosis/pulmonary embolus. A progressive mobility protocol was started in the thoracic cardiovascular intensive care unit in a rural academic medical center. The purpose of the progressive mobility protocol was to increase mobilization of postoperative patients and decrease complications related to immobility in this unique patient population. A matched-pairs design was used to compare a randomly selected sample of the preintervention group (n = 30) to a matched postintervention group (n = 30). The analysis compared outcomes including intensive care unit and hospital length of stay, intensive care unit readmission occurrence, pressure ulcer prevalence, and deep vein thrombosis/pulmonary embolism prevalence between the 2 groups. Although this comparison does not achieve statistical significance (P < .05) for any of the outcomes measured, it does show clinical significance in a reduction in hospital length of stay, intensive care unit days, in intensive care unit readmission rate, and a decline in pressure ulcer prevalence, which is the overall goal of progressive mobility. This study has implications for nursing, hospital administration, and therapy services with regard to staffing and cost savings related to fewer complications of immobility. Future studies with a larger sample size and other populations are warranted.
Sevransky, Jonathan E.; Checkley, William; Herrera, Phabiola; Pickering, Brian W.; Barr, Juliana; Brown, Samuel M; Chang, Steven Y; Chong, David; Kaufman, David; Fremont, Richard D; Girard, Timothy D; Hoag, Jeffrey; Johnson, Steven B; Kerlin, Mehta P; Liebler, Janice; O'Brien, James; O'Keefe, Terence; Park, Pauline K; Pastores, Stephen M; Patil, Namrata; Pietropaoli, Anthony P; Putman, Maryann; Rice, Todd W.; Rotello, Leo; Siner, Jonathan; Sajid, Sahul; Murphy, David J; Martin, Greg S
2015-01-01
Objective Clinical protocols may decrease unnecessary variation in care and improve compliance with desirable therapies. We evaluated whether highly protocolized intensive care units have superior patient outcomes compared with less highly protocolized intensive care units. Design Observational study in which participating intensive care units completed a general assessment and enrolled new patients one day each week. Setting and Patients 6179 critically ill patients across 59 intensive care units in the United States Critical Illness and Injury Trials Group Critical Illness Outcomes Study Interventions: None Measurements and Main Results The primary exposure was the number of intensive care unit protocols; the primary outcome was hospital mortality. 5809 participants were followed prospectively and 5454 patients in 57 intensive care units had complete outcome data. The median number of protocols per intensive care unit was 19 (IQR 15 to 21.5). In single variable analyses, there were no differences in intensive care unit and hospital mortality, length of stay, use of mechanical ventilation, vasopressors, or continuous sedation among individuals in intensive care units with a high vs. low number of protocols. The lack of association was confirmed in adjusted multivariable analysis (p=0.70). Protocol compliance with two ventilator management protocols was moderate and did not differ between intensive care units with high vs. low numbers of protocols for lung protective ventilation in ARDS (47% vs. 52%; p=0.28) and for spontaneous breathing trials (55% vs. 51%; p=0.27). Conclusions Clinical protocols are highly prevalent in United States intensive care units. The presence of a greater number of protocols was not associated with protocol compliance or patient mortality. PMID:26110488
Influence of apixaban on antifactor Xa levels in a patient with acute kidney injury.
Wendte, Jodi; Voss, Glenn; VanOverschelde, Beau
2016-04-15
The case of a patient requiring conversion from apixaban to heparin in the setting of acute kidney injury is reported. A 70-year-old man was initiated on apixaban 5 mg twice daily for new-onset, nonvalvular atrial fibrillation with a CHA2DS2-VASc score of 4, indicating a high risk of stroke. Soon after starting apixaban, he experienced pulmonary edema with pneumonia requiring hospitalization. During the course of hospitalization, the patient developed acute kidney injury requiring hemodialysis, and apixaban was stopped due to concerns about altered pharmacokinetics and impaired drug elimination in this setting. A heparin infusion was started 36 hours after the last dose of apixaban was administered. Antifactor Xa levels were monitored consistent with the hospital's standard practice protocols. The initial and repeat antifactor Xa concentrations were elevated (1.8-4.4 IU/mL) for up 72 hours after stopping the heparin infusion. Given the suspected interference of apixaban with standard antifactor Xa level monitoring, the heparin protocol was modified to reflect drip-rate adjustments based on activated partial thromboplastin times (aPTTs). The hospital protocol for heparin infusions was reinstituted on hospital day 7, with dosage adjustments based on antifactor Xa levels. The patient remained on a continuous heparin infusion for atrial fibrillation for the remainder of his hospitalization without complications or bleeding events. A 70-year-old man with new-onset nonvalvular atrial fibrillation and receiving apixaban discontinued this therapy and was given heparin instead due to acute kidney injury. His heparin dosage was successfully adjusted based on antifactor Xa levels and aPPTs. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Hodne, Kjetil; von Krogh, Kristine; Weltzien, Finn-Arne; Sand, Olav; Haug, Trude M
2012-09-01
Protocols for primary cultures of teleost cells are commonly only moderately adjusted from similar protocols for mammalian cells, the main adjustment often being of temperature. Because aquatic habitats are in general colder than mammalian body temperatures and teleosts have gills in direct contact with water, pH and buffer capacity of blood and extracellular fluid are different in fish and mammals. Plasma osmolality is generally higher in marine teleosts than in mammals. Using Atlantic cod (Gadus morhua) as a model, we have optimized these physiological parameters to maintain primary pituitary cells in culture for an extended period without loosing key properties. L-15 medium with adjusted osmolality, adapted to low pCO(2) (3.8mm Hg) and temperature (12°C), and with pH 7.85, maintained the cells in a physiologically sounder state than traditional culture medium, significantly improving cell viability compared to the initial protocol. In the optimized culture medium, resting membrane potential and response to releasing hormone were stable for at least two weeks, and the proportion of cells firing action potentials during spawning season was about seven times higher than in the original culture medium. The cells were moderately more viable when the modified medium was supplemented with newborn calf serum or artificial serum substitute. Compared to serum-free L-15 medium, expression of key genes (lhb, fshb, and gnrhr2a) was better maintained in medium containing SSR, whereas NCS tended to decrease the expression level. Although serum-free medium is adequate for many applications, serum supplement may be preferable for experiments dependent on membrane integrity. Copyright © 2012 Elsevier Inc. All rights reserved.
Mistiaen, Patriek; Achterberg, Wilco; Ament, Andre; Halfens, Ruud; Huizinga, Janneke; Montgomery, Ken; Post, Henri; Francke, Anneke L
2008-01-07
Pressure ulcers are a major problem, especially in nursing home patients, although they are regarded as preventable and there are many pressure relieving methods and materials. One such pressure relieving material is the recently developed Australian Medical Sheepskin, which has been shown in two randomized controlled trials 12 to be an effective intervention in the prevention of sacral pressure ulcers in hospital patients. However, the use of sheepskins has been debated and in general discouraged by most pressure ulcer working groups and pressure ulcer guidelines, but these debates were based on old forms of sheepskins. Furthermore, nothing is yet known about the (cost-)effectiveness of the Australian Medical sheepskin in nursing home patients. The objective of this study is to assess the effects and costs of the use of the Australian Medical Sheepskin combined with usual care with regard to the prevention of sacral pressure ulcers in somatic nursing home patients, versus usual care only. In a multi-centre randomised controlled trial 750 patients admitted for a primarily somatic reason to one of the five participating nursing homes, and not having pressure ulcers on the sacrum at admission, will be randomized to either usual care only or usual care plus the use of the Australian Medical Sheepskin as an overlay on the mattress. Outcome measures are: incidence of sacral pressure ulcers in the first month after admission; sacrum pressure ulcer free days; costs; patient comfort; and ease of use. The skin of all the patients will be observed once a day from admission on for 30 days. Patient characteristics and pressure risk scores are assessed at admission and at day 30 after it. Additional to the empirical phase, systematic reviews will be performed in order to obtain data for economic weighting and modelling. The protocol is registered in the Controlled Trial Register as ISRCTN17553857.
Mehani, Sherin Hassan Mohammed
2017-01-01
The aim of the present study was to compare threshold inspiratory muscle training (IMT) and expiratory muscle training (EMT) in elderly male patients with moderate degree of COPD. Forty male patients with moderate degree of COPD were recruited for this study. They were randomly divided into two groups: the IMT group who received inspiratory training with an intensity ranging from 15% to 60% of their maximal inspiratory pressure, and the EMT group who received expiratory training with an equal intensity which was adjusted according to the maximal expiratory pressure. Both groups received training three times per week for 2 months, in addition to their prescribed medications. Both IMT and EMT groups showed a significant improvement in forced vital capacity, forced expiratory volume in the first second, forced expiratory volume in the first second% from the predicted values, and forced vital capacity% from the predicted value, with no difference between the groups. Both types of training resulted in a significant improvement in blood gases (SaO 2 %, PaO 2 , PaCO 2 , and HCO 3 ), with the inspiratory muscle group showing the best results. Both groups showed a significant improvement in the 6-min walking distance: an increase of about 25% in the inspiratory muscle group and about 2.5% in the expiratory muscle group. Both IMT and EMT must be implemented in pulmonary rehabilitation programs in order to achieve improvements in pulmonary function test, respiratory muscle strength, blood oxygenation, and 6-min walking distance.
Olszewski, Waldemar L; Zaleska, Marzanna; Michelin, Sandro
2016-12-01
Edema fluid in lymphedematous limbs should be evacuated to sites where it can be absorbed. It should be moved either to the hypogastrium or arm/scapular regions along tissue channels or implanted silicon channels or through lymphovenous anastomoses. For that purpose, the manual lymphatic drainage of limb is an effective method. Standardization of manual massage applied force and timing becomes necessary. A device with known pressing area and continuously showing the applied force while moving it toward the root of the limb is needed. Moreover, force could be adjusted to the stiffness of the massaged tissues that varies at different levels of the limb. Results from such a device would be repeatable and reproducible by others. In this study we present data on tissue fluid hydromechanics obtained from 20 patients with obstructive limb lymphedema during massage with a massaging roller called Linforoll. Linforoll is composed of a hand piece with roller and pressure sensor connected wireless to the computer displaying the pressure curve of the applied force. Electron microscopy studies for checking eventual tissue changes were done. Linforoll provides the possibilities of: 1) regulating the applied force according to the hydromechanic conditions of the massaged tissues; 2) standardization of massage repeatable in the same patient; 3) decrease of limb volume; 4) evident increase in tissue elasticity; 5) application as a driving force for fluid flow along the surgically implanted tubing and vessels running to the lymphovenous shunts.
Arsenic exposure assists ccm3 genetic polymorphism in elevating blood pressure
Liu, Xinxia; Xing, Xiumei; Zhang, Huimin; Yun, Jianpei; Ou, Xiaoyan; Su, Xiaolin; Lu, Yao; Sun, Yi; Yang, Yarui; Jiang, Jun; Cui, Dong; Zhuang, Zhixiong; He, Yun
2018-01-01
Epidemiologic study has suggested that arsenic exposure is positively related to increased blood pressure. However, the underlying mechanism concerning interaction between genetic polymorphisms and arsenic exposure remains unclear. In present study, within 395 Chinese, the effects of interaction between arsenic exposure and CCM3 gene polymorphisms on elevation of blood pressure were probed by multiple Logistic regression models after adjusting for confounding factors. Firstly, we found that serum arsenic was positively associated with blood pressure, cholesterol, glucose and C-reactive protein. Then, adjusted for confounding factors of age, gender, smoking, alcohol consumption, BMI and degree of education, arsenic exposure incurred the hazard of increased systolic pressure and diastolic pressure, with odds ratios (ORs) being 1.725 and 1.425, respectively. Distinctly, we found that interactions between rs3804610* rs9818496, rs6784267*rs9818496, and rs3804610* rs6784267 variant genotype can increase significantly risks of SBP. Additionally, interactions between rs9818496, rs3804610 and rs6784267 genotypic variantions and arsenic exposure boosted the hazard of increased systolic pressure, with ORs being 1.496, 1.496 and 1.312. In conclusion, our fingdings suggest that As exposure of population can assist CCM3 polymorphism in elevating SBP. PMID:29435151
Zhu, Pengli; Huang, Feng; Lin, Fan; Yuan, Yin; Chen, Falin; Li, Qiaowei
2013-11-01
To describe the relationship of plasma apelin levels with blood pressure in a coastal Chinese population. This cross-sectional study included a total of 1031 subjects from the coastal areas of China. One-way analysis of variance (ANOVA) and linear trend test, Pearson's correlation analysis, as well as multivariate linear regression analysis were used to evaluate the association between plasma apelin levels and blood pressure. Plasma apelin levels dropped with increasing quartiles of systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial blood pressure (MABP) (all P<0.001). SBP, DBP, and MABP values decreased as the apelin levels increased within the quartiles. After adjusting for age and gender, the significant differences in SBP, DBP, and MABP between the groups within the apelin quartiles remained (all P<0.05). A significant negative correlation between SBP, DBP, as well as MABP and apelin levels was observed (all P<0.01); even after adjusting for cardiovascular confounding factors, this negative correlation remained (all P<0.001). A negative correlation between plasma apelin levels and blood pressure was found in this 1000-population-based epidemiological study. Apelin may become a potential therapeutic target of anti-hypertensive treatment.
Fortier, Catherine; Desjardins, Marie-Pier; Agharazii, Mohsen
2018-03-01
Aortic stiffness, measured by carotid-femoral pulse wave velocity (cf-PWV), is used for the prediction of cardiovascular risk. This mini-review describes the nonlinear relationship between cf-PWV and operational blood pressure, presents the proposed methods to adjust for this relationship, and discusses a potential place for aortic-brachial PWV ratio (a measure of arterial stiffness gradient) as a blood pressure-independent measure of vascular aging. PWV is inherently dependent on the operational blood pressure. In cross-sectional studies, PWV adjustment for mean arterial pressure (MAP) is preferred, but still remains a nonoptimal approach, as the relationship between PWV and blood pressure is nonlinear and varies considerably among individuals due to heterogeneity in genetic background, vascular tone, and vascular remodeling. Extrapolations from the blood pressure-independent stiffness parameter β (β 0 ) have led to the creation of stiffness index β, which can be used for local stiffness. A similar approach has been used for cardio-ankle PWV to generate a blood pressure-independent cardio-ankle vascular index (CAVI). It was recently demonstrated that stiffness index β and CAVI remain slightly blood pressure-dependent, and a more appropriate formula has been proposed to make the proper adjustments. On the other hand, the negative impact of aortic stiffness on clinical outcomes is thought to be mediated through attenuation or reversal of the arterial stiffness gradient, which can also be influenced by a reduction in peripheral medium-sized muscular arteries in conditions that predispose to accelerate vascular aging. Arterial stiffness gradient, assessed by aortic-brachial PWV ratio, is emerging to be at least as good as cf-PWV for risk prediction, but has the advantage of not being affected by operating MAP. The negative impacts of aortic stiffness on clinical outcomes are proposed to be mediated through attenuation or reversal of arterial stiffness gradient. Aortic-brachial PWV ratio, a measure of arterial stiffness gradient, is independent of MAP.
Hand-held instrument should relieve hematoma pressure
NASA Technical Reports Server (NTRS)
Raggio, L. J.; Robertson, T. L.
1967-01-01
Portable instrument relieves hematomas beneath fingernails and toenails without surgery. This device simplifies the operative procedure with an instant variable heating tip, adjustable depth settings and interchangeable tip sizes for cauterizing small areas and relieving pressurized clots.
Apitz, Christian; Honjo, Osami; Humpl, Tilman; Li, Jing; Assad, Renato S; Cho, Mi Y; Hong, James; Friedberg, Mark K; Redington, Andrew N
2012-12-01
Chronic right ventricular (RV) pressure overload results in pathologic RV hypertrophy and diminished RV function. Although aortic constriction has been shown to improve systolic function in acute RV failure, its effect on RV responses to chronic pressure overload is unknown. Adjustable vascular banding devices were placed on the main pulmonary artery and descending aorta. In 5 animals (sham group), neither band was inflated. In 9 animals (PAB group), only the pulmonary arterial band was inflated, with adjustments on a weekly basis to generate systemic or suprasystemic RV pressure at 28 days. In 9 animals, both pulmonary arterial and aortic devices were inflated (PAB + AO group), the pulmonary arterial band as for the PAB group and the aortic band adjusted to increase proximal systolic blood pressure by approximately 20 mm Hg. Effects on the functional performance were assessed 5 weeks after surgery by conductance catheters, followed by histologic and molecular assessment. Contractile performance was significantly improved in the PAB + AO group versus the PAB group for both ventricles. Relative to sham-operated animals, both banding groups showed significant differences in myocardial histologic and molecular responses. Relative to the PAB group, the PAB + AO group showed significantly decreased RV cardiomyocyte diameter, decreased RV collagen content, and reduced RV expression of endothelin receptor type B, matrix metalloproteinase 9, and transforming growth factor β genes. Aortic constriction in an experimental model of chronic RV pressure overload not only resulted in improved biventricular systolic function but also improved myocardial remodeling. These data suggest that chronically increased left ventricular afterload leads to a more physiologically hypertrophic response in the pressure-overloaded RV. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Evaluation of Pressure Pain Threshold as a Measure of Perceived Stress and High Job Strain
Hven, Lisbeth; Frost, Poul
2017-01-01
Objective To investigate whether pressure pain threshold (PPT), determined by pressure algometry, can be used as an objective measure of perceived stress and job strain. Methods We used cross-sectional base line data collected during 1994 to 1995 within the Project on Research and Intervention in Monotonous work (PRIM), which included 3123 employees from a variety of Danish companies. Questionnaire data included 18 items on stress symptoms, 23 items from the Karasek scale on job strain, and information on discomfort in specified anatomical regions was also collected. Clinical examinations included pressure pain algometry measurements of PPT on the trapezius and supraspinatus muscles and the tibia. Associations of stress symptoms and job strain with PPT of each site was analyzed for men and women separately with adjustment for age body mass index, and discomfort in the anatomical region closest to the point of pressure algometry using multivariable linear regression. Results We found significant inverse associations between perceived stress and PPT in both genders in models adjusting for age and body mass index: the higher level of perceived stress, the lower the threshold. For job strain, associations were weaker and only present in men. In men all associations were attenuated when adjusting for reported discomfort in regions close to the site of pressure algometry. The distributions of PPT among stressed and non-stressed persons were strongly overlapping. Conclusions Despite significant associations between perceived stress and PPT, the discriminative capability of PPT to distinguish individuals with and without stress is low. PPT measured by pressure algometry seems not applicable as a diagnostic tool of a state of mental stress. PMID:28052089
Kaess, Bernhard M; Rong, Jian; Larson, Martin G; Hamburg, Naomi M; Vita, Joseph A; Cheng, Susan; Aragam, Jayashree; Levy, Daniel; Benjamin, Emelia J; Vasan, Ramachandran S; Mitchell, Gary F
2016-03-25
The differing relations of steady and pulsatile components of central hemodynamics and aortic stiffness with cardiac dimensions and function have not been fully elucidated. Central hemodynamics and carotid-femoral pulse wave velocity (CFPWV, a measure of aortic stiffness) were measured by arterial tonometry in 5799 participants of the Framingham Heart Study (mean age 51 years, 54% women) and related to echocardiographic left ventricular (LV) dimensions and systolic and diastolic function using multivariable-adjusted partial Pearson correlations. Mean arterial pressure (MAP, steady component of central blood pressure) was associated positively with LV wall thickness (r=0.168; P<0.0001) but showed only a weak direct association with LV diastolic dimension (r=0.035, P=0.006). Central pulse pressure (pulsatile component of central blood pressure) showed a direct correlation with both LV diastolic dimension and LV wall thickness (r=0.08 and 0.044, both P<0.0001 in multivariable models that included MAP). CFPWV was not associated with LV structure (all P≥0.27) in MAP-adjusted models). Both MAP and CFPWV were associated inversely with LV diastolic function (E'; r=-0.140 and -0.153, respectively; both P<0.0001), and these associations persisted after additional adjustment for LV mass and central pulse pressure (r=-0.142 and -0.108, both P<0.0001). MAP and CFPWV were not associated with LV fractional shortening (P≥0.10), whereas central pulse pressure was positively related (r=0.064, P<0.0001). Pulsatile and steady components of central pressure are conjointly yet variably related to LV structure. CFPWV is related to LV diastolic function but not to systolic function. Additional studies are warranted to confirm these observations. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Lightweight and confidential data discovery and dissemination for wireless body area networks.
He, Daojing; Chan, Sammy; Zhang, Yan; Yang, Haomiao
2014-03-01
As a special sensor network, a wireless body area network (WBAN) provides an economical solution to real-time monitoring and reporting of patients' physiological data. After a WBAN is deployed, it is sometimes necessary to disseminate data into the network through wireless links to adjust configuration parameters of body sensors or distribute management commands and queries to sensors. A number of such protocols have been proposed recently, but they all focus on how to ensure reliability and overlook security vulnerabilities. Taking into account the unique features and application requirements of a WBAN, this paper presents the design, implementation, and evaluation of a secure, lightweight, confidential, and denial-of-service-resistant data discovery and dissemination protocol for WBANs to ensure the data items disseminated are not altered or tampered. Based on multiple one-way key hash chains, our protocol provides instantaneous authentication and can tolerate node compromise. Besides the theoretical analysis that demonstrates the security and performance of the proposed protocol, this paper also reports the experimental evaluation of our protocol in a network of resource-limited sensor nodes, which shows its efficiency in practice. In particular, extensive security analysis shows that our protocol is provably secure.
Sacrificial adhesive bonding: a powerful method for fabrication of glass microchips
Lima, Renato S.; Leão, Paulo A. G. C.; Piazzetta, Maria H. O.; Monteiro, Alessandra M.; Shiroma, Leandro Y.; Gobbi, Angelo L.; Carrilho, Emanuel
2015-01-01
A new protocol for fabrication of glass microchips is addressed in this research paper. Initially, the method involves the use of an uncured SU-8 intermediate to seal two glass slides irreversibly as in conventional adhesive bonding-based approaches. Subsequently, an additional step removes the adhesive layer from the channels. This step relies on a selective development to remove the SU-8 only inside the microchannel, generating glass-like surface properties as demonstrated by specific tests. Named sacrificial adhesive layer (SAB), the protocol meets the requirements of an ideal microfabrication technique such as throughput, relatively low cost, feasibility for ultra large-scale integration (ULSI), and high adhesion strength, supporting pressures on the order of 5 MPa. Furthermore, SAB eliminates the use of high temperature, pressure, or potential, enabling the deposition of thin films for electrical or electrochemical experiments. Finally, the SAB protocol is an improvement on SU-8-based bondings described in the literature. Aspects such as substrate/resist adherence, formation of bubbles, and thermal stress were effectively solved by using simple and inexpensive alternatives. PMID:26293346
Walia, Kavita; Argüello, Hector; Lynch, Helen; Grant, Jim; Leonard, Finola C; Lawlor, Peadar G; Gardiner, Gillian E; Duffy, Geraldine
2017-04-04
This study investigated several cleaning and disinfection protocols for their ability to eliminate Salmonella and to reduce levels of Enterobacteriaceae, within the lairage pens of a commercial pig abattoir. Eight protocols were evaluated in each of 12 lairage pens at the end of the slaughtering day on 3 occasions (36 pens/protocol): (P1) high-pressure cold water wash (herein referred to as high-pressure wash); (P2) high-pressure wash followed by a quaternary ammonium compound (QAC)-based disinfectant without rinsing; (P3) high-pressure wash followed by a chlorocresol-based disinfectant without rinsing; (P4) high-pressure wash followed by a sodium hydroxide/sodium hypochlorite detergent with rinsing; (P5) P4 followed by P2; (P6) P4 followed by P3; (P7) P5 with drying for 24-48h; and (P8) P6 with drying for 24-48h. Two floor swabs and one wall swab were taken from each lairage pen before and after each protocol was applied, and examined for the presence of Salmonella and enumeration of Enterobacteriaceae. High-pressure washing alone (P1) did not reduce the prevalence of Salmonella in the lairage pens. When high-pressure washing, the probability of detecting Salmonella following application of the chlorocresol-based disinfectant (P3) was lower than with the QAC-based disinfectant, P2 (14.2% versus 34.0%, respectively; p<0.05). The probability of detecting Salmonella after the combined use of detergent and the chlorocresol-based disinfectant (P6) was also lower than application of detergent followed by the QAC-based disinfectant, P5 (2.2% versus 17.1%, respectively; p<0.05). Drying of pens (P7 and P8) greatly reduced the probability of detecting Salmonella. Only 3.8% of swabs were Salmonella-positive 48h after cleaning with detergent and the QAC-based disinfectant (P7); while an eradication of Salmonella was achieved 24h after cleaning with detergent and the chlorocresol-based disinfectant, P8. A reduction in Enterobacteriaceae counts to below the limit of detection (LOD; 10CFU/cm 2 ) was achieved following cleaning with detergent and disinfection with the chlorocresol-based disinfectant, regardless of drying (p<0.05), whereas, applying detergent and the QAC-based disinfectant (P7) did not reduce Enterobacteriaceae counts to below the LOD. Therefore ensuring that lairage pens are allowed to dry after intensive cleaning with detergent and a chlorocresol-based disinfectant is recommended as the most effective hygiene routine to eliminate Salmonella and reduce Enterobacteriaceae counts. Copyright © 2017 Elsevier B.V. All rights reserved.
Cardiovascular and Body Fluid Adjustments During Bed Rest and Space Flight
NASA Technical Reports Server (NTRS)
Greenleaf, John E.; Tomko, David L. (Technical Monitor)
1995-01-01
Although a few scientific bed rest (BR) studies were conducted soon after World War II, advent of the space program provided impetus for utilizing prolonged (days-months) BR, which employed the horizontal or 6 degree head-down tilt (HDT) body positions, to simulate responses of healthy people to microgravity. Shorter (hours) HDT protocols were used to study initial mechanisms of the acclimation-deconditioning (reduction of physical fitness) syndromes. Of the major physiological factors modified during BR, reduced force on bones, ligaments, and muscles, and greatly reduced hydrostatic pressure within the cardiovascular system, the latter: which involves shifts of blood from the lower extremities into the upper body, increase in central venous pressure, and diuresis, appears to be the initial stimulus for acclimation. Increase in central venous pressure occurs in subjects during weightless parabolic flight, but not in astronauts early during orbital flight. But significant reduction in total body water (hypohydration) and plasma volume (hypovolemia) occurs in subjects during both BR and microgravity. Response of interstitial fluid volume is not as clear, It has been reported to increase during BR, and it may have increased in Skylab II and IV astronauts. Reduction of total body water, and greater proportional reduction of extracellular volume, indicates increased cellular volume which may contribute to inflight cephalic edema. Cerebral pressure abates after a few days of HDT, but not during flight. accompanied by normal (eugravity) blood constituent concentrations suggesting some degree of acclimation had occurred. But during reentry, with moderately increased +Gz (head-to-foot) acceleration and gravitational force, the microgravity "euhydration" becomes functional progressive dehydration contributing to the general reentry syndrome (GRS) which, upon landing the Shuttle, can and often results in gastrointestinal distress, disorientation, vertigo, fatigue, and fainting. Various pre-reentry hyperhydration procedures have been utilized to counteract the GRS. Thus, the somewhat decreased central venous pressure and lack of diuresis early in spaceflight suggests mechanisms other than the Gauer-Henry reflex are more important for maintaining fluid volume homeostasis in astronauts. Inflight hypohydration and hypovolemia are more important for maintaining fluid volume homeostasis in astronauts.
Rajachandrakumar, Roshanth; Fraser, Julia E; Schinkel-Ivy, Alison; Inness, Elizabeth L; Biasin, Lou; Brunton, Karen; McIlroy, William E; Mansfield, Avril
2017-02-01
Anticipatory postural adjustments, executed prior to gait initiation, help preserve lateral stability when stepping. Atypical patterns of anticipatory activity prior to gait initiation may occur in individuals with unilateral impairment (e.g., stroke). This study aimed to determine the prevalence, correlates, and consequences of atypical anticipatory postural adjustment patterns prior to gait initiation in a sub-acute stroke population. Forty independently-ambulatory individuals with sub-acute stroke stood on two force plates and initiated gait at a self-selected speed. Medio-lateral centre of pressure displacement was calculated and used to define anticipatory postural adjustments (shift in medio-lateral centre of pressure >10mm from baseline). Stroke severity, motor recovery, and functional balance and mobility status were also obtained. Three patterns were identified: single (typical), absent (atypical), and multiple (atypical) anticipatory postural adjustments. Thirty-five percent of trials had atypical anticipatory postural adjustments (absent and multiple). Frequency of absent anticipatory postural adjustments was negatively correlated with walking speed. Multiple anticipatory postural adjustments were more prevalent when leading with the non-paretic than the paretic limb. Trials with multiple anticipatory postural adjustments had longer duration of anticipatory postural adjustment and time to foot-off, and shorter unloading time than trials with single anticipatory postural adjustments. A high prevalence of atypical anticipatory control prior to gait initiation was found in individuals with stroke. Temporal differences were identified with multiple anticipatory postural adjustments, indicating altered gait initiation. These findings provide insight into postural control during gait initiation in individuals with sub-acute stroke, and may inform interventions to improve ambulation in this population. Copyright © 2016 Elsevier B.V. All rights reserved.
ASSOCIATION OF DAIRY CONSUMPTION AND 24-HOUR BLOOD PRESSURE IN OLDER ADULTS WITH HYPERTENSION.
Lana, Alberto; Banegas, Jose R; Guallar-Castillón, Pilar; Rodríguez-Artalejo, Fernando; Lopez-Garcia, Esther
2018-05-25
The aim was to examine the association between habitual consumption of dairy products and 24-h ambulatory blood pressure monitoring among older adults with hypertension. We conducted an analysis of 715 community-living hypertensive adults aged ≥60. Habitual dairy consumption was assessed with a validated diet history. Blood pressure was recorded by 24-hour ambulatory blood pressure monitoring; controlled blood pressure was defined as 24-hour blood pressure <130/80 mm Hg in those under drug treatment. Analyses were adjusted for main confounders, including diet, hypertension duration, and being on antihypertensive treatment. After adjustment for confounders, consumers of ≥7 servings/wk of whole milk/yogurt had a diastolic blood pressure 1.40 mm Hg higher (95% confidence interval: 0.01, 2.81) than consumers of <1 serving/wk. By contrast, consumers of ≥7 servings/wk of low-fat milk/yogurt had a diastolic blood pressure 1.74 mm Hg lower (95% confidence interval: -3.26, -0.23) than consumers of <1 serving/wk. Moreover, the odds ratio (95% confidence interval) for controlled blood pressure was 1.83 (1.05-3.08) for those consuming ≥7 servings/wk of low-fat milk/yogurt, when comparing with consumers of <1 serving/wk. Cheese consumption was not associated with blood pressure. Regular consumption of low-fat milk/yogurt was associated with lower 24-h diastolic blood pressure and with better blood pressure control among older adults with hypertension. Copyright © 2018. Published by Elsevier Inc.
Armelin, Vinicius Araújo; da Silva Braga, Victor Hugo; Abe, Augusto Shinya; Rantin, Francisco Tadeu; Florindo, Luiz Henrique
2014-10-01
Orthostasis dramatically influences the hemodynamics of terrestrial vertebrates, especially large and elongated animals such as snakes. When these animals assume a vertical orientation, gravity tends to reduce venous return, cardiac filling, cardiac output and blood pressure to the anterior regions of the body. The hypotension triggers physiological responses, which generally include vasomotor adjustments and tachycardia to normalize blood pressure. While some studies have focused on understanding the regulation of these vasomotor adjustments in ectothermic vertebrates, little is known about regulation and the importance of heart rate in these animals during orthostasis. We acquired heart rate and carotid pulse pressure (P PC) in pythons in their horizontal position, and during 30 and 60° inclinations while the animals were either untreated (control) or upon muscarinic cholinoceptor blockade and a double autonomic blockade. Double autonomic blockade completely eradicated the orthostatic-tachycardia, and without this adjustment, the P PC reduction caused by the tilts became higher than that which was observed in untreated animals. On the other hand, post-inclinatory vasomotor adjustments appeared to be of negligible importance in counterbalancing the hemodynamic effects of gravity. Finally, calculations of cardiac autonomic tones at each position revealed that the orthostatic-tachycardia is almost completely elicited by a withdrawal of vagal drive.
Diamond-anvil high-pressure cell with improved X-ray collimation system
Schiferl, David; Olinger, Barton W.; Livingston, Robert W.
1986-01-01
An adjustable X-ray collimation system for a diamond-anvil high-pressure cell of the type including a cooperable piston and cylinder and a pair of opposing diamonds located between the head of the piston and the head of the cylinder. The X-ray collimation system includes a tubular insert which contains an X-ray collimator. The insert is engageable in the bore of the piston. The collimator is mounted within the insert by means of an elastomeric O-ring at the end closest the opposed diamonds, and by means of a set of adjustable set screws at the opposite end. By adjustment of the set screws the collimator can be pivoted about the O-ring and brought into alignment with the opposed diamonds and the sample contained therein. In the preferred embodiment there is further provided a set of plugs which are insertable in the bore of the collimator. The plugs have bores of different diameters. By successively inserting plugs of progressively smaller bore diameters and adjusting the alignment of the collimator with each plug, the collimator can be quickly brought into accurate alignment with the diamonds. The collimation system allows alignment of the collimator either before or after the cell has been loaded and pressurized.
Diamond-anvil high-pressure cell with improved x-ray collimation system
Schiferl, D.; Olinger, B.W.; Livingston, R.W.
1984-03-30
An adjustable x-ray collimation system for a diamond-anvil high-pressure cell of the type including a cooperable piston and cylinder and a pair of opposing diamonds located between the head of the piston and the head of the cylinder. The x-ray collimation system includes a tubular insert which contains an x-ray collimator. The insert is engageable in the bore of the piston. The collimator is mounted within the insert by means of an elastomeric o-ring at the end closest the opposed diamonds, and by means of a set of adjustable set screws at the opposite end. By adjustment of the set screws the collimator can be pivoted about the o-ring and brought into alignment with the opposed diamonds and the sample contained therein. In the preferred embodiment there is further provided a set of plugs which are insertable in the bore of the collimator. The plugs have bores of different diameters. By successively inserting plugs of progressively smaller bore diameters and adjusting the alignment of the collimator with each plug, the collimator can be quickly brought into accurate alignment with the diamonds. The collimation system allows alignment of the collimator either before or after the cell has been loaded and pressurized.
A review of protocols for 308 nm excimer laser phototherapy in psoriasis.
Mudigonda, Tejaswi; Dabade, Tushar S; Feldman, Steven R
2012-01-01
308 nm excimer laser phototherapy is efficacious in the treatment of localized psoriasis. Different approaches regarding dose fluency, number of treatments, and maintenance have been utilized, and there is yet to be a consensus on standard protocol. To characterize treatment parameters for 308 nm excimer laser phototherapy. We performed a PubMed search for studies describing excimer laser treatment protocol with particular attention to dosage determination, dose adjustment, dose fluency, number of treatments, and maintenance. Seven prospective studies were found describing the excimer efficacy for psoriasis. All studies determined the initial treatment dose using either the minimal erythema dose (MED) or induration. Fluency ranged from 0.5 MED (low) to 16 MED (high); one study demonstrated that medium to high fluencies yielded better improvement in fewer number of treatments. Fluency adjustments during the course of treatment were important to minimize phototherapy-associated side effects. The use of higher fluencies was reported to result in higher occurrences of blistering. One study implemented a maintenance tapering of dose-frequency phase to better manage psoriasis flare-ups. The 308 nm excimer laser is an effective therapy for psoriasis regardless of the method used to determine initial dosage, dose fluency, or number of treatments. As its usage as a targeted monotherapy increases, future trials should consider evaluating and modifying these parameters to determine the most optimal management of localized psoriasis. Based on our reviewed studies, there is no consensus for a single excimer laser therapy protocol and as a result, patient preferences should continue to be an important consideration for phototherapy regimen planning.
Tsujimoto, Yasushi; Tsujimoto, Hiraku; Kataoka, Yuki; Kimachi, Miho; Shimizu, Sayaka; Ikenoue, Tatsuyoshi; Fukuma, Shingo; Yamamoto, Yosuke; Fukuhara, Shunichi
2017-04-01
To describe the registration of systematic review (SR) protocols and examine whether or not registration reduced the outcome reporting bias in high-impact journals. We searched MEDLINE via PubMed to identify SRs of randomized controlled trials of interventions. We included SRs published between August 2009 and June 2015 in the 10 general and internal medicinal journals with the highest impact factors in 2013. We examined the proportion of SR protocol registration and investigated the relationship between registration and outcome reporting bias using multivariable logistic regression. Among the 284 included reviews, 60 (21%) protocols were registered. The proportion of registration increased from 5.6% in 2009 to 27% in 2015 (P for trend <0.001). Protocol registration was not associated with outcome reporting bias (adjusted odds ratio [OR] 0.85, 95% confidence interval [CI] 0.39-1.86). The association between Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) adherence and protocol registration was not statistically significant (OR 1.09, 95% CI 0.59-2.01). Six years after the launch of the PRISMA statement, the proportion of protocol registration in high-impact journals has increased some but remains low. The present study found no evidence suggesting that protocol registration reduced outcome reporting bias. Copyright © 2017 Elsevier Inc. All rights reserved.
Interagency Dosimetry Project: Methods for Dosimetry Adjustment Based on Mode of Action
As the science of toxicology evolves, many laboratories are adding new testing protocols or assays in their programs directed at ascertaining mechanistic information on uptake and toxic action of chemicals. In response to the increasing complexity and comprehensiveness of these ...
Pérez, Glòria; Gotsens, Mercè; Palència, Laia; Marí-Dell'Olmo, Marc; Domínguez-Berjón, M Felicitas; Rodríguez-Sanz, Maica; Puig, Vanessa; Bartoll, Xavier; Gandarillas, Ana; Martín, Unai; Bacigalupe, Amaia; Díez, Elia; Ruiz, Miguel; Esnaola, Santiago; Calvo, Montserrat; Sánchez, Pablo; Luque Fernández, Miguel Ángel; Borrell, Carme
The aim is to present the protocol of the two sub-studies on the effect of the economic crisis on mortality and reproductive health and health inequalities in Spain. Substudy 1: describe the evolution of mortality and reproductive health between 1990 and 2013 through a longitudinal ecological study in the Autonomous Communities. This study will identify changes caused by the economic crisis in trends or reproductive health and mortality indicators using panel data (17 Autonomous Communities per study year) and adjusting Poisson models with random effects variance. Substudy 2: analyse inequalities by socioeconomic deprivation in mortality and reproductive health in several areas of Spain. An ecological study analysing trends in the pre-crisis (1999-2003 and 2004-2008) and crisis (2009-2013) periods will be performed. Random effects models Besag York and Mollié will be adjusted to estimate mortality indicators softened in reproductive health and census tracts. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.
An Efficient and QoS Supported Multichannel MAC Protocol for Vehicular Ad Hoc Networks
Tan, Guozhen; Yu, Chao
2017-01-01
Vehicular Ad Hoc Networks (VANETs) employ multichannel to provide a variety of safety and non-safety (transport efficiency and infotainment) applications, based on the IEEE 802.11p and IEEE 1609.4 protocols. Different types of applications require different levels Quality-of-Service (QoS) support. Recently, transport efficiency and infotainment applications (e.g., electronic map download and Internet access) have received more and more attention, and this kind of applications is expected to become a big market driver in a near future. In this paper, we propose an Efficient and QoS supported Multichannel Medium Access Control (EQM-MAC) protocol for VANETs in a highway environment. The EQM-MAC protocol utilizes the service channel resources for non-safety message transmissions during the whole synchronization interval, and it dynamically adjusts minimum contention window size for different non-safety services according to the traffic conditions. Theoretical model analysis and extensive simulation results show that the EQM-MAC protocol can support QoS services, while ensuring the high saturation throughput and low transmission delay for non-safety applications. PMID:28991217
Fuller, Brian M; Page, David; Stephens, Robert J; Roberts, Brian W; Drewry, Anne M; Ablordeppey, Enyo; Mohr, Nicholas M; Kollef, Marin H
2018-03-01
Driving pressure has been proposed as a major determinant of outcome in patients with acute respiratory distress syndrome (ARDS), but there is little data examining the association between pulmonary mechanics, including driving pressure, and outcomes in mechanically ventilated patients without ARDS. Secondary analysis from 1,705 mechanically ventilated patients enrolled in a clinical study that examined outcomes associated with the use of early lung-protective mechanical ventilation. The primary outcome was mortality and the secondary outcome was the incidence of ARDS. Multivariable models were constructed to: define the association between pulmonary mechanics (driving pressure, plateau pressure, and compliance) and mortality; and evaluate if driving pressure contributed information beyond that provided by other pulmonary mechanics. The mortality rate for the entire cohort was 26.0%. Compared with survivors, non-survivors had significantly higher driving pressure [15.9 (5.4) vs. 14.9 (4.4), P = 0.005] and plateau pressure [21.4 (5.7) vs. 20.4 (4.6), P = 0.001]. Driving pressure was independently associated with mortality [adjusted OR, 1.04 (1.01-1.07)]. Models related to plateau pressure also revealed an independent association with mortality, with similar effect size and interval estimates as driving pressure. There were 152 patients who progressed to ARDS (8.9%). Along with driving pressure and plateau pressure, mechanical power [adjusted OR, 1.03 (1.00-1.06)] was also independently associated with ARDS development. In mechanically ventilated patients, driving pressure and plateau pressure are risk factors for mortality and ARDS, and provide similar information. Mechanical power is also a risk factor for ARDS.
Wheat flour dough Alveograph characteristics predicted by Mixolab regression models.
Codină, Georgiana Gabriela; Mironeasa, Silvia; Mironeasa, Costel; Popa, Ciprian N; Tamba-Berehoiu, Radiana
2012-02-01
In Romania, the Alveograph is the most used device to evaluate the rheological properties of wheat flour dough, but lately the Mixolab device has begun to play an important role in the breadmaking industry. These two instruments are based on different principles but there are some correlations that can be found between the parameters determined by the Mixolab and the rheological properties of wheat dough measured with the Alveograph. Statistical analysis on 80 wheat flour samples using the backward stepwise multiple regression method showed that Mixolab values using the ‘Chopin S’ protocol (40 samples) and ‘Chopin + ’ protocol (40 samples) can be used to elaborate predictive models for estimating the value of the rheological properties of wheat dough: baking strength (W), dough tenacity (P) and extensibility (L). The correlation analysis confirmed significant findings (P < 0.05 and P < 0.01) between the parameters of wheat dough studied by the Mixolab and its rheological properties measured with the Alveograph. A number of six predictive linear equations were obtained. Linear regression models gave multiple regression coefficients with R²(adjusted) > 0.70 for P, R²(adjusted) > 0.70 for W and R²(adjusted) > 0.38 for L, at a 95% confidence interval. Copyright © 2011 Society of Chemical Industry.
Hozawa, Atsushi; Ohkubo, Takayoshi; Obara, Taku; Metoki, Hirohito; Kikuya, Masahiro; Asayama, Kei; Totsune, Kazuhito; Hashimoto, Junichiro; Hoshi, Haruhisa; Arai, Yumiko; Satoh, Hiroshi; Hosokawa, Toru; Imai, Yutaka
2006-11-01
To explore the effect of personality on screening blood pressures measured in clinical settings and home blood pressure measurements. From 1997 to 1999, 699 participants underwent screening and home blood pressure measurements and completed the Japanese version of the short-form Eysenck personality questionnaire. An increased screening blood pressure was defined as screening blood pressure > or = 140/90 mmHg and an increased home blood pressure was defined as home blood pressure > or = 135/85 mmHg. Participants with lower extroversion scores (i.e., introversion) showed a greater difference between screening and home systolic blood pressure. The association between introversion and differences was statistically significant, even after adjustment for other possible factors (younger age, female, wide screening pulse pressure, never smoked, and no antihypertensive medication). The adjusted means of SBP differences were 7.3 and 4.4 mmHg among the lowest and highest extroversion quartiles, respectively (P for trend = 0.02). Other personality scores (psychoticism or neuroticism) were not associated with screening and home blood pressure differences. The incorporation of an extroversion score in the basic model consisting of the above factors that affected the difference between screening and home blood pressure slightly improved the prediction of a high home blood pressure. The area under the receiver operating characteristic curve increased by 0.037 among participants with high screening blood pressure and 0.006 for those with normal screening blood pressure compared with the basic model. Physicians may need to be aware of 'introverted' patients who have high blood pressure in clinic settings, because they have the potential for 'white-coat' hypertension.
Sandrock, H.E.
1982-05-06
Static axial mixing apparatus includes a plurality of channels, forming flow paths of different dimensions. The axial mixer includes a flow adjusting device for adjustable selective control of flow resistance of various flow paths in order to provide substantially identical flows through the various channels, thereby reducing nonuniform coating of interior surfaces of the channels. The flow adjusting device may include diaphragm valves, and may further include a pressure regulating system therefor.
NASA Technical Reports Server (NTRS)
Breit, G. A.; Watenpaugh, D. E.; Buckley, T. M.; Ballard, R. E.; Murthy, G.; Hargens, A. R.
1994-01-01
The response of the cutaneous microcirculation to orthostatic stress varies along the length of the body due to the interaction of central controls with regional responses to local blood pressure. We hypothesize that artificial orthostatic stresses such as Gz centrifugation and LBNP differ from whole-body tilting in terms of the distribution of microvascular blood flow. Cutaneous microvascular flows were measured by laser Doppler flowmetry at the neck, thigh, and leg of 15 normal subjects. Volunteers underwent stepwise head-up tilt (HUT) and short- and long-arm centrifugation protocols from supine control (0 Gz) to 0.2, 0.4, 0.6, 0.8, 1.0, 0.8, 0.6, 0.4, 0.2, and 0 Gz at the feet, for 30-s periods with 10-s transitions between levels. The same subjects underwent a corresponding supine LBNP protocol, up to 100 mmHg (in 20 mmHg increments) and back to zero pressure, which produced transmural pressure across blood vessels in the foot approximately equal to the HUT protocol. In general, application of all orthostatic stresses produced significant flow reductions in the lower body (p less than 0.05) and inconsistent changes in the neck. At low levels of each stress (0.4 Gz, 40 mmHg), LBNP generated the greatest relative reduction in flow in the lower body (-66.9+/-5.7%, thigh; -60.6 +/-5.7%, leg, mean +/- SE). HUT caused a less severe flow reduction than LBNP at the thigh and leg (-39.9 +/- 8.1% and -55.9+/-4.8%), while the effects induced by both forms of centrifugation were the least profound. Higher levels of each stress generally resulted in similar responses. These responses exhibit a consistent relationship to hypothesized changes in local microvascular transmural pressure, suggesting that myogenic and veno-arteriolar reflexes play a significant role in determining microvascular perfusion during orthostatic stress.
Driver, Vickie R; Eckert, Kristen A; Carter, Marissa J; French, Michael A
2016-11-01
This study analyzed a cross-section of patients with severe chronic wounds and multiple comorbidities at an outpatient wound clinic, with regard to the cost-effectiveness and cost-benefit of negative pressure wound therapy (intervention) vs. no negative pressure wound therapy (control) at 1 and 2 years. Medicare reimbursement charges for wound care were used to calculate costs. Amputation charges were assessed using diagnosis-related groups. Cost-benefit analysis was based on ulcer-free months and cost-effectiveness on quality-adjusted life-years. Undiscounted costs, benefits, quality-adjusted life-years, undiscounted and discounted incremental net health benefits, and incremental cost-effectiveness ratios were calculated for unmatched and matched cohorts. There were 150 subjects in the intervention group and 154 controls before matching and 103 subjects in each of the matched cohorts. Time to heal for the intervention cohort was significantly shorter compared to the controls (270 vs. 635 days, p = 1.0 × 10 -7 , matched cohorts). The intervention cohort had higher benefits and quality-adjusted life-year gains compared to the control cohort at years 1 and 2; by year 2, the gains were 68-73% higher. In the unmatched cohorts, the incremental net health benefit was $9,933 per ulcer-free month at year 2 for the intervention; the incremental cost-effectiveness ratio was -825,271 per quality-adjusted life-year gained (undiscounted costs and benefits). For the matched cohorts, the incremental net health benefits was only $1,371 per ulcer-free month for the intervention, but the incremental cost-effectiveness ratio was $366,683 per quality-adjusted life-year gained for year 2 (discounted costs and benefits). In a patient population with severe chronic wounds and serious comorbidities, negative pressure wound therapy resulted in faster healing wounds and was more cost-effective with greater cost-benefits than not using negative pressure wound therapy. Regarding overall cost-effectiveness, the intervention was still expensive, but that is the reality amidst limited treatment options for such serious cases of chronic wounds. © 2016 by the Wound Healing Society.
Martínez-García, Miguel-Angel; Capote, Francisco; Campos-Rodríguez, Francisco; Lloberes, Patricia; Díaz de Atauri, María Josefa; Somoza, María; Masa, Juan F; González, Mónica; Sacristán, Lirios; Barbé, Ferrán; Durán-Cantolla, Joaquín; Aizpuru, Felipe; Mañas, Eva; Barreiro, Bienvenido; Mosteiro, Mar; Cebrián, Juan J; de la Peña, Mónica; García-Río, Francisco; Maimó, Andrés; Zapater, Jordi; Hernández, Concepción; Grau SanMarti, Nuria; Montserrat, Josep María
2013-12-11
More than 70% of patients with resistant hypertension have obstructive sleep apnea (OSA). However, there is little evidence about the effect of continuous positive airway pressure (CPAP) treatment on blood pressure in patients with resistant hypertension. To assess the effect of CPAP treatment on blood pressure values and nocturnal blood pressure patterns in patients with resistant hypertension and OSA. Open-label, randomized, multicenter clinical trial of parallel groups with blinded end point design conducted in 24 teaching hospitals in Spain involving 194 patients with resistant hypertension and an apnea-hypopnea index (AHI) of 15 or higher. Data were collected from June 2009 to October 2011. CPAP or no therapy while maintaining usual blood pressure control medication. The primary end point was the change in 24-hour mean blood pressure after 12 weeks. Secondary end points included changes in other blood pressure values and changes in nocturnal blood pressure patterns. Both intention-to-treat (ITT) and per-protocol analyses were performed. A total of 194 patients were randomly assigned to receive CPAP (n = 98) or no CPAP (control; n = 96). The mean AHI was 40.4 (SD, 18.9) and an average of 3.8 antihypertensive drugs were taken per patient. Baseline 24-hour mean blood pressure was 103.4 mm Hg; systolic blood pressure (SBP), 144.2 mm Hg; and diastolic blood pressure (DBP), 83 mm Hg. At baseline, 25.8% of patients displayed a dipper pattern (a decrease of at least 10% in the average nighttime blood pressure compared with the average daytime blood pressure). The percentage of patients using CPAP for 4 or more hours per day was 72.4%. When the changes in blood pressure over the study period were compared between groups by ITT, the CPAP group achieved a greater decrease in 24-hour mean blood pressure (3.1 mm Hg [95% CI, 0.6 to 5.6]; P = .02) and 24-hour DBP (3.2 mm Hg [95% CI, 1.0 to 5.4]; P = .005), but not in 24-hour SBP (3.1 mm Hg [95% CI, -0.6 to 6.7]; P = .10) compared with the control group. Moreover, the percentage of patients displaying a nocturnal blood pressure dipper pattern at the 12-week follow-up was greater in the CPAP group than in the control group (35.9% vs 21.6%; adjusted odds ratio [OR], 2.4 [95% CI, 1.2 to 5.1]; P = .02). There was a significant positive correlation between hours of CPAP use and the decrease in 24-hour mean blood pressure (r = 0.29, P = .006), SBP (r = 0.25; P = .02), and DBP (r = 0.30, P = .005). Among patients with OSA and resistant hypertension, CPAP treatment for 12 weeks compared with control resulted in a decrease in 24-hour mean and diastolic blood pressure and an improvement in the nocturnal blood pressure pattern. Further research is warranted to assess longer-term health outcomes. clinicaltrials.gov Identifier: NCT00616265.
Foster, Glen E; Hanly, Patrick J; Ahmed, Sofia B; Beaudin, Andrew E; Pialoux, Vincent; Poulin, Marc J
2010-09-01
Intermittent hypoxia (IH) is believed to contribute to the pathogenesis of hypertension in obstructive sleep apnea through mechanisms that include activation of the renin-angiotensin system. The objective of this study was to assess the role of the type I angiotensin II receptor in mediating an increase in arterial pressure associated with a single 6-hour IH exposure. Using a double-blind, placebo-controlled, randomized, crossover study design, we exposed 9 healthy male subjects to sham IH, IH with placebo medication, and IH with the type I angiotensin II receptor antagonist losartan. We measured blood pressure, cerebral blood flow, and ventilation at baseline and after exposure to 6 hours of IH. An acute isocapnic hypoxia experimental protocol was conducted immediately before and after exposure to IH. IH with placebo increased resting mean arterial pressure by 7.9+/-1.6 mm Hg, but mean arterial pressure did not increase with sham IH (1.9+/-1.5 mm Hg) or with losartan IH (-0.2+/-2.4 mm Hg; P<0.05). Exposure to IH prevented the diurnal decrease in the cerebral blood flow response to hypoxia, independently of the renin-angiotensin system. Finally, in contrast to other models of IH, the acute hypoxic ventilatory response did not change throughout the protocol. IH increases arterial blood pressure through activation of the type I angiotensin II receptor, without a demonstrable impact on the cerebrovascular or ventilatory response to acute hypoxia.
Bartholdy, Cecilie; Zangger, Graziella; Hansen, Lisbeth; Ginnerup-Nielsen, Elisabeth; Bliddal, Henning; Henriksen, Marius
2016-07-01
Stretching is often used in clinical practice for a variety of purposes, including pain therapy. The possible mechanism behind the effect of stretching remains to be clarified. To investigate whether 4 weeks of unilateral stretching of the calf muscles would affect local and central pain sensitivity. This study was a randomized assessor-blinded clinical study. Healthy participants (age 18 to 40) were included and randomized. Participants in the intervention group were instructed to perform 2 stretching exercises targeting the calf muscles; 3 times 30 seconds, 7 days a week for 4 weeks on the dominant leg. Participants in the control group were instructed not to do any stretching for 4 weeks. Pressure pain threshold (PPT) and temporal summation (TS) of pressure pain were measured on the stretched calf, the contra-lateral calf, and contra-lateral lower arm using a computerized cuff algometer. Analyses of variance on the per-protocol population (defined as participants that adhered to the protocol) were used to assess group differences in the changes from baseline. Forty healthy volunteers were included, of which 34 participants adhered to the protocol (15 intervention group/19 control group). No statistically significant group differences in the changes from baseline were found regarding PPT and TS measurements for the stretched calf, the contra-lateral calf, and the arm. Four weeks of regular stretching of the calf muscles does not affect pressure pain sensitivity, suggesting that pressure pain sensitivity is unaffected by stretching in a healthy population. The mechanisms underlying any benefits of regular stretching remain to be explained. © 2015 World Institute of Pain.
L'Her, E; Duquesne, F; Paris, A; Mouline, J; Renault, A; Garo, B; Boles, J M
1998-06-20
Intubation and ventilatory assistance are often required in patients presenting severe hypoxemic respiratory distress, but may be contraindicated in elderly subjects due to an underlying condition. The aim of this study was to assess the feasibility, acceptability and contribution of early assistance with spontaneous positive end-expiratory pressure ventilation for elderly subjects admitted to an emergency unit for acute respiratory distress due to cardiogenic pulmonary edema. In our emergency admission unit, all patients with life-threatening hypoxemic respiratory distress are initially assisted with noninvasive spontaneous positive end-expiratory pressure ventilation using a standardized commercial device. We retrospectively analyzed the the files of all patients aged over 70 years who were treated with this standard protocol for cardiogenic pulmonary edema from April 1996 through September 1997. During the study period, 36 patients aged over 70 years required ventilatory assistance according to the standard protocol. Intubation was not reasonable in most of the patients (n = 30). After 1 hour of ventilation, none of the patients developed clinical signs of life-threatening distress. Blood gases demonstrated improved oxygenation (AEPO2 = +184.9 +/- 105.4 mmHg; p < 0.000001). Thirty-two patients were considered to be cured (88.9%) and were discharged; the cardiovascular condition was fatal in 4 patients (11.1%). The rapid improvement in clinical signs and blood gases as well as the final outcome suggests that early assistance with spontaneous positive end-expiratory pressure ventilation is warranted at admission for elderly patients with respiratory distress due to cardiogenic pulmonary edema. Compared with a control group of hospitalized patients cared for during the preceding year and who were not treated with the standard protocol, we also demonstrated a clear improvement in mortality (11% versus 20%).
Hasan, Y; Go, J; Hashmi, S M; Valestin, J; Schey, R
2015-04-01
The standard protocol for esophageal manometry involves placing the patient in the supine position with head turned to left (supine head left [SHL]) while evaluating liquid bolus swallows. Routinely, semisolid or solid boluses are not evaluated. Currently, the daily American diet includes up to 40% solid or semisolid texture. Thus far, the data on the effect of different bolus on high-resolution esophageal pressure topography (HREPT) parameters are scarce. This study aims to evaluate the effect of every day bolus consistencies in different body positions on HREPT variables. HREPT was performed on healthy volunteers with a modified protocol including liquid swallows in the SHL position followed by applesauce (semisolid), cracker (solid), and marshmallow (soft solid) in three different positions (SHL, sitting, and standing). A total of 38 healthy adult subjects (22 males and 16 females, median age = 27, and mean body mass index = 25) were evaluated. The resting upper esophageal sphincter pressure was significantly different while subjects swallowed crackers, applesauce, and marshmallows in most positions compared with liquid SHL (P < 0.05). The lower esophageal sphincter, contractile front velocity, and distal contractile integral pressures did not differ in all different consistencies compared with SHL. The integrated relaxation period was significantly higher with solid bolus compared with liquid bolus only in SHL position. The intrabolus pressure was significantly different with solid and soft solid boluses in all postures compared to liquid SHL. The American diet consistency affects upper esophageal sphincter pressure and partially integrated relaxation period and intrabolus pressure in various positions. Semisolid bolus swallows do not cause substantial pressure changes and are safe for evaluation and maintaining adequate caloric intake in patients with dysphagia who cannot tolerate solids. © 2014 International Society for Diseases of the Esophagus.
Pressure-flow reducer for aerosol focusing devices
Gard, Eric; Riot, Vincent; Coffee, Keith; Woods, Bruce; Tobias, Herbert; Birch, Jim; Weisgraber, Todd
2008-04-22
A pressure-flow reducer, and an aerosol focusing system incorporating such a pressure-flow reducer, for performing high-flow, atmosphere-pressure sampling while delivering a tightly focused particle beam in vacuum via an aerodynamic focusing lens stack. The pressure-flow reducer has an inlet nozzle for adjusting the sampling flow rate, a pressure-flow reduction region with a skimmer and pumping ports for reducing the pressure and flow to enable interfacing with low pressure, low flow aerosol focusing devices, and a relaxation chamber for slowing or stopping aerosol particles. In this manner, the pressure-flow reducer decouples pressure from flow, and enables aerosol sampling at atmospheric pressure and at rates greater than 1 liter per minute.
Patel, Akash R; Ganley, Jamie; Zhu, Xiaowei; Rome, Jonathan J; Shah, Maully; Glatz, Andrew C
2014-10-01
Radiation exposure during pediatric catheterization is significant. We sought to describe radiation exposure and the effectiveness of radiation safety protocols in reducing exposure during catheter ablations with electrophysiology studies in children and patients with congenital heart disease. We additionally sought to identify at-risk patients. We retrospectively reviewed all interventional electrophysiology procedures performed from April 2009 to September 2011 (6 months preceding intervention, 12 months following implementation of initial radiation safety protocol, and 8 months following implementation of modified protocol). The protocols consisted of low pulse rate fluoroscopy settings, operator notification of skin entrance dose every 1,000 mGy, adjusting cameras by >5 at every 1,000 mGy, and appropriate collimation. The cohort consisted of 291 patients (70 pre-intervention, 137 after initial protocol implementation, 84 after modified protocol implementation) at a median age of 14.9 years with congenital heart disease present in 11 %. Diagnoses included atrioventricular nodal reentrant tachycardia (25 %), atrioventricular reentrant tachycardia (61 %), atrial tachycardias (12 %), and ventricular tachycardia (2 %). There were no differences between groups based on patient, arrhythmia, and procedural characteristics. Following implementation of the protocols, there were significant reductions in all measures of radiation exposure: fluoroscopy time (17.8 %), dose area product (80.2 %), skin entry dose (81.0 %), and effective dose (76.9 %), p = 0.0001. Independent predictors of increased radiation exposure included larger patient weight, longer fluoroscopy time, and lack of radiation safety protocol. Implementation of a radiation safety protocol for pediatric and congenital catheter ablations can drastically reduce radiation exposure to patients without affecting procedural success.
Engelhardt, Othmar G.; Wood, John; Heath, Alan; Katz, Jacqueline M.; Peiris, Malik; Hoschler, Katja; Hungnes, Olav; Zhang, Wenqing; Van Kerkhove, Maria D.
2015-01-01
The microneutralization assay is commonly used to detect antibodies to influenza virus, and multiple protocols are used worldwide. These protocols differ in the incubation time of the assay as well as in the order of specific steps, and even within protocols there are often further adjustments in individual laboratories. The impact these protocol variations have on influenza serology data is unclear. Thus, a laboratory comparison of the 2-day enzyme-linked immunosorbent assay (ELISA) and 3-day hemagglutination (HA) microneutralization (MN) protocols, using A(H1N1)pdm09, A(H3N2), and A(H5N1) viruses, was performed by the CONSISE Laboratory Working Group. Individual laboratories performed both assay protocols, on multiple occasions, using different serum panels. Thirteen laboratories from around the world participated. Within each laboratory, serum sample titers for the different assay protocols were compared between assays to determine the sensitivity of each assay and were compared between replicates to assess the reproducibility of each protocol for each laboratory. There was good correlation of the results obtained using the two assay protocols in most laboratories, indicating that these assays may be interchangeable for detecting antibodies to the influenza A viruses included in this study. Importantly, participating laboratories have aligned their methodologies to the CONSISE consensus 2-day ELISA and 3-day HA MN assay protocols to enable better correlation of these assays in the future. PMID:26108286
Polo Friz, Hernan; Punzi, Veronica; Petri, Francesco; Orlandi, Riccardo; Maggiolini, Daniele; Polo Friz, Melisa; Primitz, Laura; Vighi, Giuseppe
2017-10-01
This study aimed to perform a simultaneous, third-party, independent validation of the oscillometric SunTech CT40 device for blood pressure (BP) measurement, according to the 1993 protocol of the British Hypertension Society and the standard of the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) 81060-2:2013. Patient recruitment, study procedures, and data analysis followed the recommendations stated by the protocols. The study was approved by the institutional review board. A total of 94 participants were included, 52 (55.3%) women, mean±SD age: 63.1±18.0 years, mean±SD arm circumference: 35.0±9.0 cm. The average of observers' entry BPs was 146.9±37.2 mmHg for systolic blood pressure (SBP) and 82.2±22.1 mmHg for diastolic blood pressure (DBP). Differences between the standard measurement and the test device within 5, 10, and 15 mmHg, for the better observer, were 79.4, 96.5, and 100.0% for SBP and 82.6, 97.5, and 100.0% for DBP, respectively. The mean±SD differences between the readings obtained using the test device and those obtained by the observers (AAMI/ISO 81060-2:2013 standard criterion 1) were 0.3±5.0 mmHg (SBP) and -0.8±4.3 mmHg (DBP), and the mean±SD differences between average of reference readings and average of test device readings in each patient (criterion 2) were 0.3±3.9 and -0.8±3.5 mmHg for SBP and DBP, respectively. The CT40 BP device achieved A/A grade of the British Hypertension Society protocol and fulfilled the requirements (criteria 1 and 2) of the AAMI/ISO standard. CT40 can be recommended for BP measurement in adults.
Roy R. Rosenberger; Carl J. Houtman
2000-01-01
The USPS Image Analysis (IA) protocol recommends the use of hydrophobic dyes to develop contrast between pressure sensitive adhesive (PSA) particles and cellulosic fibers before using a dirt counter to detect all contaminants that have contrast with the handsheet background. Unless the sample contains no contaminants other than those of interest, two measurement steps...
Beime, Beate; Krüger, Ralf; Hammel, Gertrud; Bramlage, Peter; Deutsch, Cornelia
2018-02-01
The aim of the present study was to validate the blood pressure (BP) measurement device, Microlife BP A3 PC, in patients with diabetes mellitus, according to the ANSI/AAMI/ISO 81060-2:2013 protocol. In 85 individuals aged 56-88 years, with predefined criteria for diabetes mellitus, BP measurements on the upper arm were performed alternately using the Microlife BP A3 PC and a standard mercury reference sphygmomanometer. A total of 333 comparisons were included for analysis. The mean difference between the Microlife BP A3 PC and the reference was -1.5±6.3 mmHg for systolic BP (SBP) and -1.3±5.2 mmHg for diastolic BP (DBP) according to criterion 1 of the protocol. For SBP, a total of 209 of the 333 measurements were within the range of 5 mmHg (62.8%), whereas the corresponding numbers for DBP were 232 of 333 (69.7%). For criterion 2, the intraindividual differences for the test device and the reference were -1.50±4.73 mmHg for SBP and -1.30±4.55 mmHg for DBP, thus being within the defined ranges provided by the protocol. The Microlife BP A3 PC fulfilled the requirements of criteria 1 and 2 of the ANSI/AAMI/ISO 81060-2:2013 protocol and can also be recommended for BP measurement in diabetic patients.
The Effects of Compression-Garment Pressure on Recovery After Strenuous Exercise.
Hill, Jessica; Howatson, Glyn; van Someren, Ken; Gaze, David; Legg, Hayley; Lineham, Jack; Pedlar, Charles
2017-09-01
Compression garments are frequently used to facilitate recovery from strenuous exercise. To identify the effects of 2 different grades of compression garment on recovery indices after strenuous exercise. Forty-five recreationally active participants (n = 26 male and n = 19 female) completed an eccentric-exercise protocol consisting of 100 drop jumps, after which they were matched for body mass and randomly but equally assigned to a high-compression pressure (HI) group, a low-compression pressure (LOW) group, or a sham ultrasound group (SHAM). Participants in the HI and LOW groups wore the garments for 72 h postexercise; participants in the SHAM group received a single treatment of 10-min sham ultrasound. Measures of perceived muscle soreness, maximal voluntary contraction (MVC), countermovement-jump height (CMJ), creatine kinase (CK), C-reactive protein (CRP), and myoglobin (Mb) were assessed before the exercise protocol and again at 1, 24, 48, and 72 h postexercise. Data were analyzed using a repeated-measures ANOVA. Recovery of MVC and CMJ was significantly improved with the HI compression garment (P < .05). A significant time-by-treatment interaction was also observed for jump height at 24 h postexercise (P < .05). No significant differences were observed for parameters of soreness and plasma CK, CRP, and Mb. The pressures exerted by a compression garment affect recovery after exercise-induced muscle damage, with higher pressure improving recovery of muscle function.
Yip, Gabriel Wai-Kwok; So, Hung-Kwan; Li, Albert Martin; Tomlinson, Brian; Wong, Sik-Nin; Sung, Rita Yn-Tz
2012-04-01
The A&D TM-2430 ambulatory blood pressure (BP) monitor has been validated in adults but not in a young population. We sought to validate the device monitoring in children and adolescents, according to the British Hypertension Society (BHS) protocol. The A&D TM-2430 is an automated oscillometric upper-arm device for ambulatory BP monitoring. Nine consecutive measurements were taken in 61 children (mean age, 9.8 years; range, 5-15 years) according to the BHS criteria. Overseen by an independent supervisor, measurements were recorded by two observers blinded from each other's readings and from the device readings. The mean difference ± SD between the observers and device measurements was 0.73 ± 1.64 mmHg for systolic blood pressure (SBP) and -1.23 ± 1.65 mmHg for diastolic blood pressure (DBP), respectively, with an interobserver difference of 4 mmHg. The cumulative percentages of differences within 5, 10, and 15 mmHg were 89, 95, and 98% for SBP and 67, 88, and 98% for DBP. The device achieved a grade A rating for SBP and a B grade for DBP. The A&D TM-2430 upper-arm BP monitor has fulfilled the required BHS standards and can be recommended for measuring ambulatory BP in children and adolescent populations.
Blankman, Paul; Hasan, Djo; van Mourik, Martijn S; Gommers, Diederik
2013-06-01
The purpose of this study was to compare the effect of varying levels of assist during pressure support (PSV) and Neurally Adjusted Ventilatory Assist (NAVA) on the aeration of the dependent and non-dependent lung regions by means of Electrical Impedance Tomography (EIT). We studied ten mechanically ventilated patients with Acute Lung Injury (ALI). Positive-End Expiratory Pressure (PEEP) and PSV levels were both 10 cm H₂O during the initial PSV step. Thereafter, we changed the inspiratory pressure to 15 and 5 cm H₂O during PSV. The electrical activity of the diaphragm (EAdi) during pressure support ten was used to define the initial NAVA gain (100 %). Thereafter, we changed NAVA gain to 150 and 50 %, respectively. After each step the assist level was switched back to PSV 10 cm H₂O or NAVA 100 % to get a new baseline. The EIT registration was performed continuously. Tidal impedance variation significantly decreased during descending PSV levels within patients, whereas not during NAVA. The dorsal-to-ventral impedance distribution, expressed according to the center of gravity index, was lower during PSV compared to NAVA. Ventilation contribution of the dependent lung region was equally in balance with the non-dependent lung region during PSV 5 cm H₂O, NAVA 50 and 100 %. Neurally Adjusted Ventilatory Assist ventilation had a beneficial effect on the ventilation of the dependent lung region and showed less over-assistance compared to PSV in patients with ALI.
Critical scaling of a jammed system after a quench of temperature.
Otsuki, Michio; Hayakawa, Hisao
2012-09-01
Critical behavior of soft repulsive particles after quench of temperature near the jamming transition is numerically investigated. It is found that the plateau of the mean-square displacement of tracer particles and the pressure satisfy critical scaling laws. The critical density for the jamming transition depends on the protocol to prepare the system, while the values of the critical exponents which are consistent with the prediction of a phenomenology are independent of the protocol.
Women’s bike seats: a pressing matter for competitive female cyclists
Guess, Marsha K.; Partin, Sarah N.; Schrader, Steven; Lowe, Brian; LaCombe, Julie; Reutman, Susan; Wang, Andrea; Toennis, Christine; Melman, Arnold; Mikhail, Madgy; Connell, Kathleen A.
2011-01-01
Introduction There are numerous genital complaints in women cyclists, including pain, numbness and edema of pelvic floor structures. Debate ensues about the best saddle design for protection of the pelvic floor. Aim To investigate the relationships between saddle design, seat pressures and genital nerve function in female, competitive cyclists. Methods We previously compared genital sensation in healthy, premenopausal, competitive women bicyclists and runners. The 48 cyclists from our original study comprise the study group in this sub-analysis. Main Outcome Measures (1) Genital vibratory thresholds (VT) were determined using the Medoc Vibratory Sensation Analyzer 3000. (2) Saddle pressures as determined using a specially designed map sensor. Results More than half of the participants (54.8%) used traditional saddles and the remainder (45.2%), rode with cut-out saddles. On bivariate analysis, use of traditional saddles was associated with lower mean perineal saddle pressures (MPSP) than riding on cut-out saddles. Peak perineal saddle pressures (PPSP) were also lower; however, the difference did not reach statistical significance. Saddle design did not affect mean or peak total saddle pressures (MTSP, PTSP). Saddle width was significantly associated with PPSP, MTSP and PTSP, but not with MPSP. Women riding cut-out saddles had, on average, a 4 and 11 kPa increase in MPSP and PPSP, respectively, compared to women using traditional saddles (p= 0.008 and p= 0.010), after adjustment for other variables. Use of wider saddles was associated with lower PPSP and MTSP after adjustment. Although an inverse correlation was seen between saddle pressures and VTs on bivariate analysis, these differences were not significant after adjusting for age. Conclusion Cut-out and narrower saddles negatively affect saddle pressures in female cyclists. Effects of saddle design on pudendal nerve sensory function were not apparent in this cross-sectional analysis. Longitudinal studies evaluating the long-term effects of saddle pressure on the integrity of the pudendal nerve, pelvic floor and sexual function are warranted. PMID:21834869
Women's bike seats: a pressing matter for competitive female cyclists.
Guess, Marsha K; Partin, Sarah N; Schrader, Steven; Lowe, Brian; LaCombe, Julie; Reutman, Susan; Wang, Andrea; Toennis, Christine; Melman, Arnold; Mikhail, Madgy; Connell, Kathleen A
2011-11-01
There are numerous genital complaints in women cyclists, including pain, numbness, and edema of pelvic floor structures. Debate ensues about the best saddle design for protection of the pelvic floor. To investigate the relationships between saddle design, seat pressures, and genital nerve function in female, competitive cyclists. We previously compared genital sensation in healthy, premenopausal, competitive women bicyclists and runners. The 48 cyclists from our original study comprise the study group in this subanalysis. Main outcome measures were: (i) genital vibratory thresholds (VTs) determined using the Medoc Vibratory Sensation Analyzer 3000 and (ii) saddle pressures as determined using a specially designed map sensor. More than half of the participants (54.8%) used traditional saddles, and the remainder (45.2%) rode with cut-out saddles. On bivariate analysis, use of traditional saddles was associated with lower mean perineal saddle pressures (MPSP) than riding on cut-out saddles. Peak perineal saddle pressures (PPSP) were also lower; however, the difference did not reach statistical significance. Saddle design did not affect mean or peak total saddle pressures (MTSP, PTSP). Saddle width was significantly associated with PPSP, MTSP, and PTSP but not with MPSP. Women riding cut-out saddles had, on average, a 4 and 11 kPa increase in MPSP and PPSP, respectively, compared with women using traditional saddles (P = 0.008 and P = 0.010), after adjustment for other variables. Use of wider saddles was associated with lower PPSP and MTSP after adjustment. Although an inverse correlation was seen between saddle pressures and VTs on bivariate analysis, these differences were not significant after adjusting for age. Cut-out and narrower saddles negatively affect saddle pressures in female cyclists. Effects of saddle design on pudendal nerve sensory function were not apparent in this cross-sectional analysis. Longitudinal studies evaluating the long-term effects of saddle pressure on the integrity of the pudendal nerve, pelvic floor, and sexual function are warranted. © 2011 International Society for Sexual Medicine.
Retnakaran, Ravi; Wen, Shi Wu; Tan, Hongzhuan; Zhou, Shujin; Ye, Chang; Shen, Minxue; Smith, Graeme N; Walker, Mark C
2017-04-01
Population-level sociologic studies have suggested that adverse societal conditions may affect fetal viability in a sex-specific manner and thereby modify the ratio of male vs. female babies. This concept suggests that there may exist certain physiologic features in a woman that relate to her likelihood of delivering a boy or girl. We thus established a preconception cohort to prospectively evaluate the relationship between maternal pregravid health and sex of the baby. In this analysis nested within an observational cohort study, 1,411 newly married women in Liuyang, China, underwent pregravid cardiometabolic characterization (including anthropometry and measurement of blood pressure, cholesterol, triglycerides, and glucose) at median 26.3 weeks before a singleton pregnancy, delivering at 39.0 ± 1.3 weeks gestation. Systolic blood pressure before pregnancy was higher in women who delivered a boy than in those who had a girl (112.5 ± 11.9 vs. 109.6 ± 12.0 mm Hg, P < 0.0001). The prevalence of a male baby progressively increased across quintiles of pregravid systolic blood pressure (P < 0.0001). After covariate adjustment, mean adjusted pregravid systolic blood pressure was higher in mothers of boys vs. girls (106.0 vs. 103.3 mm Hg, P = 0.0015). On logistic regression analysis, pregravid systolic blood pressure emerged as the only significant predictor of having a male baby (adjusted odds ratio = 1.017 per mm Hg, 95% confidence interval = 1.007-1.028). The pregravid difference in blood pressure between mothers of boys and girls was not present during any trimester of pregnancy. Maternal blood pressure before pregnancy is a previously unrecognized factor that may be associated with the likelihood of delivering a boy or girl. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com
NASA Astrophysics Data System (ADS)
Cai, Le; Mao, Xiaobing; Ma, Zhexuan
2018-02-01
This study first constructed the nonlinear mathematical model of the high-pressure common rail (HPCR) system in the diesel engine. Then, the nonlinear state transformation was performed using the flow’s calculation and the standard state space equation was acquired. Based on sliding-mode variable structure control (SMVSC) theory, a sliding-mode controller for nonlinear systems was designed for achieving the control of common rail pressure and the diesel engine’s rotational speed. Finally, on the simulation platform of MATLAB, the designed nonlinear HPCR system was simulated. The simulation results demonstrate that sliding-mode variable structure control algorithm shows favorable control performances and overcome the shortcomings of traditional PID control in overshoot, parameter adjustment, system precision, adjustment time and ascending time.
Potential Biomarkers for Bevacizumab-Induced High Blood Pressure in Patients With Solid Tumor
2012-02-23
Breast Cancer; Cardiovascular Complications; Colorectal Cancer; Fallopian Tube Cancer; Head and Neck Cancer; Lung Cancer; Ovarian Cancer; Peritoneal Cavity Cancer; Unspecified Adult Solid Tumor, Protocol Specific
Hussain, I; Brady, C; Swinn, M; Mathias, C; Fowler, C
2001-01-01
OBJECTIVES—To assess the efficacy and safety of sildenafil citrate (Viagra) in men with erectile dysfunction and parkinsonism due either to Parkinson's disease or multiple system atrophy. METHODS—Twenty four patients with erectile disease were recruited, 12 with Parkinson's disease and 12 with multiple system atrophy, into a randomised, double blind, placebo controlled, crossover study of sildenafil citrate. The starting dose was 50 mg active or placebo medication with the opportunity for dose adjustment depending on efficacy and tolerability. The international index of erectile function questionnaire (IIEF) was used to assess treatment efficacy and a quality of life questionnaire to assess the effect of treatment on sex life and whole life. Criteria for entry included a definite neurological diagnosis and a standing systolic blood pressure of 90-180 mm Hg and diastolic blood pressure of 50-110 mm Hg, on treatment if necessary. Blood pressure was taken at randomisation (visit 2) and crossover (visit 5) lying, sitting, and standing, before and 1 hour after taking the study medication in hospital. RESULTS—Sidenafil citrate was efficacious in men with parkinsonism with a significant improvement, as demonstrated in questionnaire responses, in ability to achieve and maintain an erection and improvement in quality of sex life. In Parkinson's disease there was minimal change in blood pressure between active and placebo medication. In multiple system atrophy, six patients were studied before recruitment was stopped because three men showed a severe drop in blood pressure 1 hour after taking the active medication. Two were already known to have orthostatic hypotension and were receiving treatment with ephedrine and midodrine but the third had asymptomatic hypotension. However, the blood pressures in all three had been within the inclusion criterion for the study protocol. Despite a significant postural fall in blood pressure after sildenafil, all patients with multiple system atrophy reported a good erectile response and were reluctant to discontinue the medication. CONCLUSIONS—Sidenafil citrate (50 mg) is efficacious in the treatment of erectile dysfunction in parkinsonism due to Parkinson's disease or multiple system atrophy; however, it may unmask or exacerbate hypotension in multiple system atrophy. As Parkinson's disease may be diagnostically difficult to distinguish from multiple system atrophy, especially in the early stages, we recommend measurement of lying and standing blood pressure before prescribing sildenafil to men with parkinsonism. Furthermore, such patients should be made aware of seeking medical advice if they develop symptoms on treatment suggestive of orthostatic hypotension. PMID:11511713
Mexican-Origin Parents’ Work Conditions and Adolescents’ Adjustment
Wheeler, Lorey A.; Updegraff, Kimberly A.; Crouter, Ann
2015-01-01
Mexican-origin parents’ work experiences are a distal extra-familial context for adolescents’ adjustment. This two-wave multi-informant study examined the prospective mechanisms linking parents’ work conditions (i.e., self-direction, work pressure, workplace discrimination) to adolescents’ adjustment (i.e., educational expectations, depressive symptoms, risky behavior) across the transition to high school drawing on work socialization and spillover models. We examined the indirect effects of parental work conditions on adolescent adjustment through parents’ psychological functioning (i.e., depressive symptoms, role overload) and aspects of the parent-adolescent relationship (i.e., parental solicitation, parent-adolescent conflict), as well as moderation by adolescent gender. Participants were 246 predominantly immigrant, Mexican-origin, two-parent families who participated in home interviews when adolescents were approximately 13 and 15 years of age. Results supported the positive impact of fathers’ occupational self-direction on all three aspects of adolescents’ adjustment through decreased father-adolescent conflict, after controlling for family socioeconomic status and earner status, and underemployment. Parental work pressure and discrimination were indirectly linked to adolescents’ adjustment, with different mechanisms emerging for mothers and fathers. Adolescents’ gender moderated the associations between fathers’ self-direction and girls’ depressive symptoms, and fathers’ experiences of discrimination and boys’ risk behavior. Results suggest that Mexican-origin mothers’ and fathers’ perceptions of work conditions have important implications for multiple domains of adolescents’ adjustment across the transition to high school. PMID:25938710
Mexican-origin parents' work conditions and adolescents' adjustment.
Wheeler, Lorey A; Updegraff, Kimberly A; Crouter, Ann
2015-06-01
Mexican-origin parents' work experiences are a distal extrafamilial context for adolescents' adjustment. This 2-wave multiinformant study examined the prospective mechanisms linking parents' work conditions (i.e., self-direction, work pressure, workplace discrimination) to adolescents' adjustment (i.e., educational expectations, depressive symptoms, risky behavior) across the transition to high school drawing on work socialization and spillover models. We examined the indirect effects of parental work conditions on adolescent adjustment through parents' psychological functioning (i.e., depressive symptoms, role overload) and aspects of the parent-adolescent relationship (i.e., parental solicitation, parent-adolescent conflict), as well as moderation by adolescent gender. Participants were 246 predominantly immigrant, Mexican-origin, 2-parent families who participated in home interviews when adolescents were approximately 13 and 15 years of age. Results supported the positive impact of fathers' occupational self-direction on all 3 aspects of adolescents' adjustment through decreased father-adolescent conflict, after controlling for family socioeconomic status and earner status, and underemployment. Parental work pressure and discrimination were indirectly linked to adolescents' adjustment, with different mechanisms emerging for mothers and fathers. Adolescents' gender moderated the associations between fathers' self-direction and girls' depressive symptoms, and fathers' experiences of discrimination and boys' risk behavior. Results suggest that Mexican-origin mothers' and fathers' perceptions of work conditions have important implications for multiple domains of adolescents' adjustment across the transition to high school. (c) 2015 APA, all rights reserved).
Validation of a Cephalad Fluid Shift Countermeasure
NASA Technical Reports Server (NTRS)
Macias, B.; Cole, C.; Kesari, S.; Hargens, A.; Stenger, M.; Ebert, D.; Lee, S. M. C.; Sargsyan, A.; Liu, J.
2016-01-01
INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.
Sorenmo, Karin; Overley, B; Krick, E; Ferrara, T; LaBlanc, A; Shofer, F
2010-09-01
A dose-intensified/dose-dense chemotherapy protocol for canine lymphoma was designed and implemented at the Veterinary Hospital of the University of Pennsylvania. In this study, we describe the clinical characteristics, prognostic factors, efficacy and toxicity in 130 dogs treated with this protocol. The majority of the dogs had advanced stage disease (63.1% stage V) and sub-stage b (58.5%). The median time to progression (TTP) and lymphoma-specific survival were 219 and 323 days, respectively. These results are similar to previous less dose-intense protocols. Sub-stage was a significant negative prognostic factor for survival. The incidence of toxicity was high; 53.9 and 45% of the dogs needed dose reductions and treatment delays, respectively. Dogs that required dose reductions and treatment delays had significantly longer TTP and lymphoma-specific survival times. These results suggest that dose density is important, but likely relative, and needs to be adjusted according to the individual patient's toxicity for optimal outcome.
Middleton, Sandy; Coughlan, Kelly; Mnatzaganian, George; Low Choy, Nancy; Dale, Simeon; Jammali-Blasi, Asmara; Levi, Chris; Grimshaw, Jeremy M; Ward, Jeanette; Cadilhac, Dominique A; McElduff, Patrick; Hiller, Janet E; D'Este, Catherine
2017-05-01
Implementation of nurse-initiated protocols to manage fever, hyperglycemia, and swallowing dysfunction decreased death and disability 90 days poststroke in the QASC trial (Quality in Acute Stroke Care) conducted in 19 Australian acute stroke units (2005-2010). We now examine long-term all-cause mortality. Mortality was ascertained using Australia's National Death Index. Cox proportional hazards regression compared time to death adjusting for correlation within stroke units using the cluster sandwich (Huber-White estimator) method. Primary analyses included treatment group only unadjusted for covariates. Secondary analysis adjusted for age, sex, marital status, education, and stroke severity using multiple imputation for missing covariates. One thousand and seventy-six participants (intervention n=600; control n=476) were followed for a median of 4.1 years (minimum 0.3 to maximum 70 months), of whom 264 (24.5%) had died. Baseline demographic and clinical characteristics were generally well balanced by group. The QASC intervention group had improved long-term survival (>20%), but this was only statistically significant in adjusted analyses (unadjusted hazard ratio [HR], 0.79; 95% confidence interval [CI], 0.58-1.07; P =0.13; adjusted HR, 0.77; 95% CI, 0.59-0.99; P =0.045). Older age (75-84 years; HR, 4.9; 95% CI, 2.8-8.7; P <0.001) and increasing stroke severity (HR, 1.5; 95% CI, 1.3-1.9; P <0.001) were associated with increased mortality, while being married (HR, 0.70; 95% CI, 0.49-0.99; P =0.042) was associated with increased likelihood of survival. Cardiovascular disease (including stroke) was listed either as the primary or secondary cause of death in 80% (211/264) of all deaths. Our results demonstrate the potential long-term and sustained benefit of nurse-initiated multidisciplinary protocols for management of fever, hyperglycemia, and swallowing dysfunction. These protocols should be a routine part of acute stroke care. URL: http://www.anzctr.org.au. Unique identifier: ACTRN12608000563369. © 2017 American Heart Association, Inc.
Bird, Yelena; Lemstra, Mark; Rogers, Marla
2017-03-01
Stroke is a major chronic disease and a common cause of adult disability and mortality. Although there are many known risk factors for stroke, lower income is not one that is often discussed. To determine the unadjusted and adjusted association of income distribution on the prevalence of stroke in Saskatchewan, Canada. Information was collected from the Canadian Community Health Survey conducted by Statistics Canada for 2000-2008. In total, 178 variables were analysed for their association with stroke. Prior to statistical adjustment, stroke was seven times more common for lower income residents than higher income residents. After statistical adjustment, only four covariates were independently associated with stroke prevalence, including having high blood pressure (odds ratio (OR) = 2.62; 95% confidence interval (CI) = 2.12-3.24), having a household income below CAD$30,000 per year (OR = 2.49; 95% CI = 1.88-3.29), being a daily smoker (OR = 1.36; 95% CI = 1.16-1.58) and being physically inactive (OR = 1.27; 95% CI = 1.13-1.43). After statistical adjustment, there were five covariates independently associated with high blood pressure prevalence, including having a household income below CAD$30,000 per year (OR = 1.52; 95% CI = 1.41-1.63). After statistical adjustment, there were five covariates independently associated with daily smoking prevalence, including having a household income below CAD$30,000 per year (OR = 1.29; 95% CI = 1.25-1.33). Knowledge of disparities in the prevalence, severity, disability and mortality of stroke is critically important to medical and public health professionals. Our study found that income distribution was strongly associated with stroke, its main disease intermediary - high blood pressure - and its main risk factor - smoking. As such, income is an important variable worthy of public debate as a modifiable risk factor for stroke.
Topouchian, Jirar; Agnoletti, Davide; Blacher¹, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland
2014-01-01
Background Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. Methods The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. Results All four tested devices passed the validation process. The mean differences between the device and mercury readings were: −1.8±5.1 mmHg and −0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and −1.2±4.3 mmHg for the Omron HEM-7420 device; −0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Conclusion Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly. PMID:24476688
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, John R.; Brubaker, Erik; Vetter, Kai
In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. Furthermore, the expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate.more » Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. In the three areas we analyzed, San Francisco, Downtown Oakland, and Berkeley, all demonstrated a suppression in the background rate of over 50% for the range of sky-view factors measured. This effect, which is due to the shielding of cosmic-ray produced neutrons by surrounding buildings, was comparable to the pressure influence which yielded a 32% suppression in the count rate over the range of pressures measured.« less
Hosseinpour-Niazi, Somayeh; Mirmiran, Parvin; Sohrab, Golbon; Hosseini-Esfahani, Firoozeh; Azizi, Fereidoun
2011-11-01
To evaluate the association between total dietary fiber and its types and sources with the risk of MetS. This population-based cross-sectional study was conducted on a representative sample of 2457 adults (1327 male and 1130 female), aged 19-84 years. Dietary intake was assessed using a validated semiquantitative food-frequency questionnaire. Anthropometrics, blood pressure, and fasting blood glucose and lipids were measured according to standard protocols. The MetS was defined according to definition by Adult Treatment Panel III. Multivariate-adjusted odds ratio of MetS between highest and lowest quartiles was 0.53 (95% CI: 0.39-0.74; P for trend <0.05) for total dietary fiber, 0.60 (0.43-0.84; P for trend <0.05) for soluble fiber, and 0.51 (0.35-0.72; P for trend <0.05) for insoluble fiber. Among sources of dietary fiber, fruit fiber (OR: 0.51; 95% CI: 0.37-0.72), cereal fiber (0.74; 0.57-0.97), and legume fiber (0.73; 0.53-0.99) were inversely associated with the risk of MetS, after adjustment for confounding factors. Intake of vegetable fiber and nut fiber were unrelated to the risk of MetS. Total dietary fiber, soluble- and insoluble fiber, fruit fiber, cereal fiber and legume fiber were associated with a protective effect for the presence of MetS among this Tehranian population. Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All rights reserved.
Prehospital Nitroglycerin in Tachycardic Chest Pain Patients: A Risk for Hypotension or Not?
Proulx, Marie-Hélène; de Montigny, Luc; Ross, Dave; Vacon, Charlene; Juste, Louis Enock; Segal, Eli
2017-01-01
The American Heart Association guidelines (AHA) guidelines list tachycardia as a contraindication for the administration of nitroglycerin (NTG), despite limited evidence of adverse events. We sought to determine whether NTG administered for chest pain was a predictor of hypotension (systolic blood pressure <90 mmHg) in patients with tachycardia, compared to patients without tachycardia (50≥ heart rate ≤100). We performed a retrospective cohort study using patient care reports completed by basic life support (BLS) providers in a large urban Canadian EMS system for the period 2010-2012. We used logistic regression to test the association between post-NTG hypotension and tachycardia, independent of pre-NTG blood pressure, age, sex, and comorbidities. Using identical models, we tested four secondary outcomes (drop in blood pressure, reduced consciousness, bradycardia, and cardiac arrest). The cohort included 10,308 patients who were administered NTG by BLS in the prehospital setting; 2,057 (20%) of patients were tachycardic before NTG administration. Hypotension occurred in 320 of all patients (3.1%): 239 without tachycardia (2.9%) and 81 with tachycardia (3.9%). Compared to non-tachycardic patients, tachycardic patients showed increased adjusted odds of hypotension (AOR: 1.60; 95% CI: 1.23-2.08) or of a drop in blood pressure of 30mm Hg or greater (AOR: 1.11; CI: 1.00-1.24). Tachycardia was associated with decreased odds of bradycardia (OR: 0.33; CI: 0.17-0.64). We did not find a significant association between tachycardia and either post-NTG reduced level of consciousness or cardiac arrest. We did find a strong, significant association between pre-NTG blood pressure and post-NTG hypotension (AOR for units of 10mmHg: 0.64; CI: 0.61-0.69). Hypotension following prehospital administration of NTG was infrequent in patients with chest pain. However, while the absolute risk of NTG-induced hypotension was low, patients with pre-NTG tachycardia had a significant increase in the relative risk of hypotension. In addition, hypotension occurred most frequently in patients presenting with a lower pre-NTG blood pressure, which may prove to be a more discriminating basis for future guidelines. EMS medical directors should review BLS chest pain protocols to weigh the benefits of NTG administration against its risks.
A pressure ulcer prevention programme specially designed for nursing homes: does it work?
Kwong, Enid W-Y; Lau, Ada T-Y; Lee, Rainbow L-P; Kwan, Rick Y-C
2011-10-01
The aim of this study was to evaluate a pressure ulcer prevention programme for nursing homes to ascertain the feasibility of its implementation, impact on care staff and outcomes for pressure ulcer knowledge and skills and pressure ulcer reduction. No pressure ulcer prevention protocol for long-term care settings has been established to date. The first author of this study thus developed a pressure ulcer prevention programme for nursing homes. A quasi-experimental pretest and post-test design was adopted. Forty-one non-licensed care providers and eleven nurses from a government-subsidised nursing home voluntarily participated in the study. Knowledge and skills of the non-licensed care providers were assessed before, immediately after and six weeks after the training course, and pressure ulcer prevalence and incidence were recorded before and during the protocol implementation. At the end of the programme implementation, focus group interviews with the subjects were conducted to explore their views on the programme. A statistically significant improvement in knowledge and skills scores amongst non-licensed care providers was noted. Pressure ulcer prevalence and incidence rates dropped from 9-2·5% and 2·5-0·8%, respectively, after programme implementation. The focus group findings indicated that the programme enhanced the motivation of non-licensed care providers to improve their performance of pressure ulcer prevention care and increased communication and cooperation amongst care staff, but use of the modified Braden scale was considered by nurses to increase their workload. A pressure ulcer prevention programme for nursing homes, which was feasible and acceptable, with positive impact and outcome in a nursing home was empirically developed. The study findings can be employed to modify the programme and its outcomes for an evaluation of effectiveness of the programme through a randomised controlled trial. © 2011 Blackwell Publishing Ltd.
Family Economic Stress and Adjustment of Early Adolescent Girls.
ERIC Educational Resources Information Center
Conger, Rand D.; And Others
1993-01-01
Adolescent girls and their parents and a sibling completed questionnaires that measured several family variables and were observed interacting. Found that family economic pressures led to parents' depression, marital conflict, and disrupted parenting. Parents' depressed mood and disrupted child-rearing practices affected girls' adjustment. (BC)
Campbell, Eric G; Vogeli, Christine; Rao, Sowmya R; Abraham, Melissa; Pierson, Roz; Applebaum, Sandra
2015-09-01
For the past decade, more attention and concern has been directed toward financial relationships between the life science industry and physicians. Relationships between industry and institutional review board (IRB) members represent an important subclass that has the potential to broadly influence decisions regarding medical research. To study the nature, extent, and perceived consequences of industry relationships among IRB members in academic health centers and to compare our results with findings from 2005. A survey mailed to IRB members from the 115 most research-intensive medical schools and teaching hospitals in the United States from January 16 through May 16, 2014. The survey included questions identical to those used in 2005. Data analysis was conducted from June through October 2014. The frequency of industry relationships among IRB members and the perceived effect of those relationships on IRB-related activities. We found no significant change in the percentage of IRB members with an industry relationship from 2005 through 2014 (2005: 37.2%; 95% CI, 32.7%-42.0%; 2014: 32.1%; 95% CI, 28.0%-36.4%; P = .09). However, since 2005, the percentage of members who felt another member did not properly disclose a financial relationship decreased from 10.8% (95% CI, 8.0%-14.4%) to 6.7% (95% CI, 4.7%-9.4%) (P = .04), as did the percentage who felt pressure from their institution or department to approve a protocol (2005: 18.6%; 95% CI, 15.0%-22.9%; 2014: 10.0%; 95% CI, 7.6%-13.0%; P < .001). The percentage of members with a conflict of interest who voted on protocols with which they have a conflict has not changed, although the percentage who said they always disclose relationships increased significantly from 54.9% in 2005 (95% CI, 42.2%-66.9%) to 80.0% in 2014 (95% CI, 65.3%-89.4%) (P = .01). We also found evidence of anti-industry bias in the presentation of protocols to the IRB. The results show significant positive progress in the reporting and management of conflicts of interest among IRB members in academic health centers since 2005 after adjusting for other factors. Additional attention should be focused on deterring IRB members from inappropriately voting on or presenting protocols in a biased manner.
Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System
NASA Astrophysics Data System (ADS)
Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren
2017-11-01
The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.
Palmer, Suetonia C; Ruospo, Marinella; Barulli, Maria Rosaria; Iurillo, Annalisa; Saglimbene, Valeria; Natale, Patrizia; Gargano, Letizia; Murgo, Angelo M; Loy, Clement; van Zwieten, Anita; Wong, Germaine; Tortelli, Rosanna; Craig, Jonathan C; Johnson, David W; Tonelli, Marcello; Hegbrant, Jörgen; Wollheim, Charlotta; Logroscino, Giancarlo; Strippoli, G F M
2015-12-09
The prevalence of cognitive impairment may be increased in adults with end-stage kidney disease compared with the general population. However, the specific patterns of cognitive impairment and association of cognitive dysfunction with activities of daily living and clinical outcomes (including withdrawal from treatment) among haemodialysis patients remain incompletely understood. The COGNITIVE impairment in adults with end-stage kidney disease treated with HemoDialysis (COGNITIVE-HD) study aims to characterise the age-adjusted and education-adjusted patterns of cognitive impairment (using comprehensive testing for executive function, perceptual-motor function, language, learning and memory, and complex attention) in patients on haemodialysis and association with clinical outcomes. A prospective, longitudinal, cohort study of 750 adults with end-stage kidney disease treated with long-term haemodialysis has been recruited within haemodialysis centres in Italy (July 2013 to April 2014). Testing for neurocognitive function was carried out by a trained psychologist at baseline to assess cognitive functioning. The primary study factor is cognitive impairment and secondary study factors will be specific domains of cognitive function. The primary outcome will be total mortality. Secondary outcomes will be cause-specific mortality, major cardiovascular events, fatal and non-fatal myocardial infarction and stroke, institutionalisation, and withdrawal from treatment at 12 months. This protocol was approved before study conduct by the following responsible ethics committees: Catania (approval reference 186/BE; 26/09/2013), Agrigento (protocol numbers 61-62; 28/6/2013), USL Roma C (CE 39217; 24/6/2013), USL Roma F (protocol number 0041708; 23/7/2013), USL Latina (protocol number 20090/A001/2011; 12/7/2013), Trapani (protocol number 3413; 16/7/2013) and Brindisi (protocol number 40259; 6/6/2013). All participants have provided written and informed consent and can withdraw from the study at any time. The findings of the study will be disseminated through peer-reviewed journals and national and international conference presentations and to the participants through communication within the dialysis network in which this study is conducted. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Pressure vessel and method therefor
Saunders, Timothy
2017-09-05
A pressure vessel includes a pump having a passage that extends between an inlet and an outlet. A duct at the pump outlet includes at least one dimension that is adjustable to facilitate forming a dynamic seal that limits backflow of gas through the passage.
NASA Technical Reports Server (NTRS)
Walker, Neil (Inventor); Day, Stanley G. (Inventor); Collopy, Paul D. (Inventor); Bennett, George W. (Inventor)
1988-01-01
An integrated control system for coaxial counterrotating aircraft propulsors driven by a common gas turbine engine. The system establishes an engine pressure ratio by control of fuel flow and uses the established pressure ratio to set propulsor speed. Propulsor speed is set by adjustment of blade pitch.
Donovan, Michelle L; Muller, Michael J; Simpson, Claire; Rudd, Michael; Paratz, Jennifer
2016-04-26
Pressure garment therapy (PGT) is well accepted and commonly used by clinicians in the treatment of burns scars and grafts. The medium to high pressures (24-40 mmHg) in these garments can support scar minimisation, and evidence is well documented for this particular application. However, PGT specifically for burn donor sites, of which a sequela is also scarring, is not well documented. This study protocol investigates the impact of a low pressure (4-6 mmHg) interim garment on donor site healing and scarring. With a primary purpose of holding donor dressings in place, the application of the interim pressure garment (IPG) appears to have been twofold. IPGs for donor sites have involved inconsistent application with a focus on securing wound dressing rather than scar management. However, anecdotal and observational evidence suggests that IPGs also make a difference to some patient's scar outcomes for donor sites. This study protocol outlines a randomised controlled trial designed to test the effectiveness of this treatment on reducing scarring to burn donor sites. This study is a single-centre, single (assessor)-blinded, randomised control trial in patients with burns donor sites to their thighs. Patients will be randomly allocated to a control group (with no compression to donor sites) or to an experimental group (with compression to donor sites) as the comparative treatment. Groups will be compared at baseline regarding the important prognostic indicators: donor site location, depth, size, age, and time since graft (5 days). The IPG treatment will be administered post-operatively (on day 5). Follow-up assessments and garment replacement will be undertaken fortnightly for a period of 2 months. This study focuses on a unique area of burns scar management using a low-pressure tubular support garment for the reduction of donor site scars. Such therapy specifically for donor scar management is poorly represented in the literature. This study was designed to test a potentially cost-effective scar prevention for patients with donor sites to the thigh. No known studies of this nature have been carried out to date, and there is a need for rigorous clinical evidence for low-pressure support garments for donor site scar minimisation. Australian New Zealand Clinical Trials Registry identifier ACTRN12610000127000 . Registered 8 Mar 2010.
Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang
2018-02-01
The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.
Arazi, Hamid; Asadi, Abbas; Rahimzadeh, Mehdi; Moradkhani, Amir-Hossein
2013-12-01
The purpose of this study was to compare the effects of high, moderate and low intensity plyometric exercise on the post-exercise systolic and diastolic blood pressure and heart rate responses. Ten healthy normotensive men (age, 21.1±0.9 years; height, 175.8±6 cm; and body mass, 69.1±13.6 kg) volunteered to participate in this study and were evaluated for three non-consecutive days in depth jump exercise from 20-cm box (low intensity [LI]), 40-cm box (moderate intensity [MI]) and 60-cm box (high intensity [HI]) for 5 sets of 20 repetitions. After each exercise session, systolic blood pressure (SBP), diastolic blood pressure (DBP) and heart rate (HR) were measured every 10 min for a period of 90 min. No significant differences were observed among post-exercise SBP, DBP and HR when the protocols (LI, MI and HI) were compared. The LI and HI protocols showed greater reduction in SBP at 40(th)-70(th) min of post-exercise (~9%), whereas the LI and MI protocols indicated greater reduction in DBP at 10(th)-50(th) min of post exercise (~10%). In addition, the change in the DBP for HI was not significant and the increases in the HR were similar for all intensities. It can be concluded that a plyometric exercise (PE) can reduce SBP and DBP post-exercise and therefore we can say that PE has significant effects for reducing BP and HR or post-exercise hypotension.
2017-08-01
iss052e024957 (Aug. 1, 2017) --- Astronaut Paolo Nespoli ingressed the Muscle Atrophy Research & Exercise System (MARES) chair in the Columbus module and adjusted pads and constraints for the Sarcolab-3 ankle protocol. The data collected for Sarcolab-3 will be compared to pre and postflight measurements to assess the impact of hypothesized microgravity induced muscle loss.
ERIC Educational Resources Information Center
Villeneuve, Julie; Lamarre, Diane; Lussier, Marie-Therese; Vanier, Marie-Claude; Genest, Jacques; Blais, Lucie; Hudon, Eveline; Perreault, Sylvie; Berbiche, Djamal; Lalonde, Lyne
2009-01-01
Introduction: In a physician-pharmacist collaborative-care (PPCC) intervention, community pharmacists were responsible for initiating lipid-lowering pharmacotherapy and adjusting the medication dosage. They attended a 1-day interactive workshop supported by a treatment protocol and clinical and communication tools. Afterwards, changes in…
Cochrane, Suzanne; Smith, Caroline A.; Possamai-Inesedy, Alphia; Bensoussan, Alan
2016-01-01
The global average of couples with fertility problems is 9%. Assisted reproductive technologies are often inaccessible. Evidence points to acupuncture offering an opportunity to promote natural fertility. This study asked whether providing a multiphasic fertility acupuncture protocol to women with sub/infertility would increase their awareness of fertility and achieve normalisation of their menstrual cycle compared with a lifestyle control. In a pragmatic randomised controlled trial sub/infertile women were offered an intervention of acupuncture and lifestyle modification or lifestyle modification only. There was a statistically significant increase in fertility awareness in the acupuncture group (86.4%, 19) compared to 40% (n = 8) of the lifestyle only participants (Relative Risk (RR) 2.38, 95% confidence interval (CI) of 1.25, 4.50), with an adjusted p value of 0.011. Changes in menstrual regularity were not statistically significant. There was no statistical difference in the pregnancy rate with seven women (adjusted p = 0.992) achieving pregnancy during the course of the study intervention. Those receiving the acupuncture conceived within an average of 5.5 weeks compared to 10.67 weeks for the lifestyle only group (p = 0.422). The acupuncture protocol tested influenced women who received it compared to women who used lifestyle modification alone: their fertility awareness and wellbeing increased, and those who conceived did so in half the time. PMID:27242910
Idiopathic constipation: A challenging but manageable problem.
Bischoff, Andrea; Brisighelli, Giulia; Dickie, Belinda; Frischer, Jason; Levitt, Marc A; Peña, Alberto
2017-10-10
A protocol to treat idiopathic constipation is presented. A contrast enema is performed in every patient and, when indicated, patients are initially submitted to a "clean out" protocol. All patients are started on a Senna-based laxative. The initial dosage is empirically determined and adjusted daily, during a one week period, based on history and abdominal radiographs, until the amount of Senna that empties the colon is reached. The management is considered successful when patients empty their colon daily and stop soiling. If the laxatives dose provokes abdominal cramping, distension, and vomiting, without producing bowel movements, patients are considered nonmanageable. From 2005 to 2012, 215 patients were treated. 121 (56%) were males. The average age was 8.2years (range: 1-20). 160 patients (74%) presented encopresis. 67 patients (32%) needed a clean out. After one week, 181 patients (84%) achieved successful management, with an average Senna dose of 67mg (range: 5-175mg). In 34 patients (16%) the treatment was unsuccessful: 19 were nonmanageable, 3 noncompliant, and 12 continued soiling. At a later follow-up (median: 329days) the success rate for 174 patients was 81%. We designed a successful protocol to manage idiopathic constipation. The key points are clean out before starting laxatives, individual adjustments of laxative, and radiological monitoring of colonic emptying. Level IV. Copyright © 2017 Elsevier Inc. All rights reserved.
Bret, P; Guyotat, J; Ricci, A C; Mottolese, C; Jouanneau, E
1999-05-01
Evaluate the advantages, results and drawbacks of the Sophy adjustable valve (SV) in the treatment of hydrocephalus in the adult. One-hundred and forty-seven adult hydrocephalic patients (mean age = 64.5 years) shunted with a SV between 1990 and 1997 were retrospectively reviewed. Etiologies of hydrocephalus were: "normal pressure" chronic hydrocephalus (NPH) in 124 and tumoral hydrocephalus with intracranial hypertension in 23 patients. One-hundred fifty shunts were established in 147 patients: 14 ventriculoatrial and 136 ventriculoperitoneal shunts. The initial pressure settings of the SV were: high pressure: 12 times (8%), medium pressure: 136 times (90.6%) and low pressure: 2 times (1.3%). Sixteen patients were lost to follow-up. Two patients died within hours following the procedure. So, the results were analyzed in the 129 remaining patients, with a follow-up of 16.7 months (+/- 17.8). Three patients died from shunted-related causes (2.3%). Eighty-four patients had good results (65%), 25 had fair results (19.5%) and 20 failed to improve or deteriorated (15.5%) after shunting. Fifty-three reoperations were performed in 44 patients (34%), including 37 procedures for mechanical obstruction and 6 for septic complications. Subdural effusions (SDE) occurred in 16 patients (12.5%): 10 surgical evacuations were required in 7 patients; 8 patients were successfully treated using uprating of the SV pressure alone; one was managed conservatively. Fifty-eight pressure readjustments were performed in 47 patients. The pressure settings were uprated 28 times in patients showing clinical or computerized tomographic (CT) features suggesting overdrainage; 20 of those proved to be successful (71.5%). The pressure settings were lowered 30 times in patients showing a lack of improvement after shunting, attributed to underdrainage; only 12 of those proved to be successful (40%). Spontaneous changes of the pressure settings were observed in 14 patients (10.8%). After a MRI exposure, SV pressure changes were observed in 64% of patients. The technological refinements that have been proposed to eliminate the overdrainage which occurs in most usual cerebrospinal fluid shunts are reviewed. The SV valve has allowed non-invasive adjustments of its opening pressure in patients showing complications ascribed to inappropriate drainage. The need for additional surgery was eliminated in 20% to 25% of patients of the present series. Because of frequent spontaneous and magnetic resonance-induced pressure changes, the need for repeated controls of valve pressure is to be reemphasized. This experience suggests that the SV represents a substantial improvement over standard fixed-pressure valves.
Arterial stiffness in normotensive and hypertensive subjects: Frequency in community pharmacies.
Rodilla Sala, Enrique; Adell Alegre, Manuel; Giner Galvañ, Vicente; Perseguer Torregrosa, Zeneida; Pascual Izuel, Jose Maria; Climent Catalá, María Teresa
2017-12-07
Arterial stiffness (AS) is a well-recognized target organ lesion. This study aims to determine: 1) the frequency of AS in community pharmacies; 2) if stiffened subjects identified by brachial oscillometry have more CV risk factors than normal subjects, and 3) the dependence of stiffness on using either age-adjusted values or a fixed threshold. Observational, cross-sectional study in 32 community pharmacies of the Valencia Community, between November/2015 and April/2016. Stiffness was as pulse wave velocity (PWV) measured with a semi-automatic, validated device (Mobil-O-Graph ® , IEM), followed by a 10-item questionnaire. Mean age of the 1,427 consecutive recruited patients was 56.6 years. Overall proportion of patients with AS was 17.4% with age-adjusted PWV (9.4% in normotensives, 28.3% in hypertensives). Multivariate logistic regression showed independent association of stiffness in normotensives with male gender, obesity, higher pulse pressure and heart rate, in hypertensives, with higher pulse pressure and lower age. AS was globally found in 20.5% of subjects, defining stiffness by PWV>10m/s (6.2% in normotensives, 40.2% in hypertensives). It was associated with higher age and pulse pressure in both groups. Concordance in classifying stiffness was 74.6%. Frequency of AS varied between 17.4-20.5%. Age-adjusted stiffness is associated in normotensives with male gender, pulse pressure, obesity and heart rate, in hypertensives with pulse pressure and inversely to age. Stiffness by 10m/s is determined by higher pulse pressure and higher age. Both definitions of PWV are not interchangeable. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.
Hajjar, Ihab; Goldstein, Felicia C; Martin, Greg S; Quyyumi, Arshed A
2016-01-01
Although there is strong evidence that hypertension leads to cognitive decline, especially in the executive domain, the relationship between blood pressure and cognition has been conflicted. Hypertension is characterized by blood pressure elevation and increased arterial stiffness. We aimed at investigating whether arterial stiffness would be superior to blood pressure in predicting cognitive decline and explaining the hypertension-executive decline association. A randomly selected asymptomatic population (n=591, age=49.2 years, 70% women, 27% black, and education=18 years) underwent annual vascular and cognitive assessments. Cognition was assessed using computerized versions commonly used cognitive tests, and principal component analysis was used for deriving cognitive scores for executive function, memory, and working memory. Arterial stiffness was measured by carotid-femoral pulse wave velocity (PWV). Higher PWV, but not blood pressure, was associated with a steeper decline in executive (P=0.0002), memory (P=0.05), and working memory (P=0.02) scores after adjusting for demographics, education, and baseline cognitive performance. This remained true after adjusting for hypertension. Hypertension was associated with greater decline in executive score (P=0.0029) and those with combined hypertension and elevated PWV (>7 m/s) had the greatest decline in executive score (P value hypertension×PWV=0.02). PWV explained the association between hypertension and executive function (P value for hypertension=0.0029 versus 0.24 when adjusting for PWV). In healthy adults, increased arterial stiffness is superior to blood pressure in predicting cognitive decline in all domains and in explaining the hypertension-executive function association. Arterial stiffness, especially in hypertension, may be a target in the prevention of cognitive decline. © 2015 American Heart Association, Inc.
Markus, Marcello Ricardo Paulista; Stritzke, Jan; Lieb, Wolfgang; Mayer, Björn; Luchner, Andreas; Döring, Angela; Keil, Ulrich; Hense, Hans-Werner; Schunkert, Heribert
2008-10-01
It is unclear whether persistent prehypertension causes structural or functional alterations of the heart. We examined echocardiographic data of 1005 adults from a population-based survey at baseline in 1994/1995 and at follow-up in 2004/2005. We compared individuals who had either persistently normal (<120 mmHg systolic and <80 mmHg diastolic, n = 142) or prehypertensive blood pressure (120-139 mmHg or 80-89 mmHg, n = 119) at both examinations using multivariate regression modeling. Over 10 years, left ventricular end-diastolic diameters were stable and did not differ between the two groups. However, the prehypertensive blood pressure group displayed more pronounced ageing-related increases of left ventricular wall thickness (+4.7 versus +11.9%, P < 0.001) and left ventricular mass (+8.6 versus +15.7%, P = 0.006). Prehypertension was associated with a raised incidence of left ventricular concentric remodeling (adjusted odds ratio 10.7, 95% confidence interval 2.82-40.4) and left ventricular hypertrophy (adjusted odds ratio 5.33, 1.58-17.9). The ratio of early and late diastolic peak transmitral flow velocities (E/A) decreased by 7.7% in the normal blood pressure versus 15.7% in the prehypertensive blood pressure group (P = 0.003) and at follow-up the ratio of early diastolic peak transmitral flow and early diastolic peak myocardial relaxation velocities (E/EM) was higher (9.1 versus 8.5, P = 0.031) and left atrial size was larger (36.5 versus 35.3 mm, P = 0.024) in the prehypertensive blood pressure group. Finally, the adjusted odds ratio for incident diastolic dysfunction was 2.52 (1.01-6.31) for the prehypertensive blood pressure group. Persistent prehypertension accelerates the development of hypertrophy and diastolic dysfunction of the heart.
da Silva, Fabiana Alves; Vidal, Cláudia Fernanda de Lacerda; de Araújo, Ednaldo Cavalcante
2015-01-01
Abstract Objective: to validate the content of the prevention protocol for early sepsis caused by Streptococcus agalactiaein newborns. Method: a transversal, descriptive and methodological study, with a quantitative approach. The sample was composed of 15 judges, 8 obstetricians and 7 pediatricians. The validation occurred through the assessment of the content of the protocol by the judges that received the instrument for data collection - checklist - which contained 7 items that represent the requisites to be met by the protocol. The validation of the content was achieved by applying the Content Validity Index. Result: in the judging process, all the items that represented requirements considered by the protocol obtained concordance within the established level (Content Validity Index > 0.75). Of 7 items, 6 have obtained full concordance (Content Validity Index 1.0) and the feasibility item obtained a Content Validity Index of 0.93. The global assessment of the instruments obtained a Content Validity Index of 0.99. Conclusion: the validation of content that was done was an efficient tool for the adjustment of the protocol, according to the judgment of experienced professionals, which demonstrates the importance of conducting a previous validation of the instruments. It is expected that this study will serve as an incentive for the adoption of universal tracking by other institutions through validated protocols. PMID:26444165
Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong
2012-11-01
The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.
Embracing additive manufacture: implications for foot and ankle orthosis design
2012-01-01
Background The design of foot and ankle orthoses is currently limited by the methods used to fabricate the devices, particularly in terms of geometric freedom and potential to include innovative new features. Additive manufacturing (AM) technologies, where objects are constructed via a series of sub-millimetre layers of a substrate material, may present the opportunity to overcome these limitations and allow novel devices to be produced that are highly personalised for the individual, both in terms of fit and functionality. Two novel devices, a foot orthosis (FO) designed to include adjustable elements to relieve pressure at the metatarsal heads, and an ankle foot orthosis (AFO) designed to have adjustable stiffness levels in the sagittal plane, were developed and fabricated using AM. The devices were then tested on a healthy participant to determine if the intended biomechanical modes of action were achieved. Results The adjustable, pressure relieving FO was found to be able to significantly reduce pressure under the targeted metatarsal heads. The AFO was shown to have distinct effects on ankle kinematics which could be varied by adjusting the stiffness level of the device. Conclusions The results presented here demonstrate the potential design freedom made available by AM, and suggest that it may allow novel personalised orthotic devices to be produced which are beyond the current state of the art. PMID:22642941
NASA Technical Reports Server (NTRS)
Norcross, Jason; Jarvis, Sarah; Bekdash, Omar; Cupples, Scott; Abercromby, Andrew
2017-01-01
The primary objective of this study is to develop a protocol to reliably characterize human health and performance metrics for individuals working inside various EVA suits under realistic spaceflight conditions. Expected results and methodologies developed during this study will provide the baseline benchmarking data and protocols with which future EVA suits and suit configurations (e.g., varied pressure, mass, center of gravity [CG]) and different test subject populations (e.g., deconditioned crewmembers) may be reliably assessed and compared. Results may also be used, in conjunction with subsequent testing, to inform fitness-for-duty standards, as well as design requirements and operations concepts for future EVA suits and other exploration systems.
Effects of Thermal Status on Markers of Blood Coagulation During Simulated Hemorrhage
2017-06-01
analogous to the effects of salt consumption on blood pressure where individuals are often defined as “salt-sensitive” or “salt-insensitive” (40). For...Ventilatory parameters ( ventilation , tidal volume and breathing rate) were measured (body temperature and pressure saturated) using an automated gas...method of cooling rapidly decreases the mean skin temperature with little initial effect on Tcore (see Results). Experimental protocol 2 This
Lopez, Michele Antonio; Andreasi Bassi, Mirko; Confalone, Luca; Carinci, Francesco
2014-01-01
The current study describes an innovative protocol for the surgical maxillary sinus augmentation via a crestal approach that uses hydraulic pressure to lift the Schneiderian membrane and simultaneously fill the subantral space with a biomaterial for bone regeneration (nanocrystalline hydroxyapatite in aqueous solution). The technique in question combines the advantages of large amounts of grafted biomaterial with reduced trauma, high precision, and predictability.
Effect of an Exercise Protocol on Pelvic Muscle Resting Pressure in Healthy Adult Women.
1992-01-01
function as it related to the postpartum period, parity, type of delivery, episiotomy, age, breastfeeding, physical activity, body mass, stress urinary...incontinence, and orgasm in 98 healthy postpartal and nonpostpartal women. Pelvic muscle pressure measurements were made with the intravaginal balloon...subjects may be performing contractions while the pelvic muscles are still in a partially contracted state from the previous stimulation . The longer resting
Temporal trends of postinjury multiple-organ failure: Still resource intensive, morbid, and lethal
Sauaia, Angela; Moore, Ernest E.; Johnson, Jeffrey L.; Chin, Theresa L.; Banerjee, Anirban; Sperry, Jason L.; Maier, Ronald V.; Burlew, C. Cothren
2014-01-01
BACKGROUND While the incidence of postinjury multiple-organ failure (MOF) has declined during the past decade, temporal trends of its morbidity, mortality, presentation patterns, and health care resources use have been inconsistent. The purpose of this study was to describe the evolving epidemiology of postinjury MOF from 2003 to 2010 in multiple trauma centers sharing standard treatment protocols. METHODS “Inflammation and Host Response to Injury Collaborative Program” institutions that enrolled more than 20 eligible patients per biennial during the 2003 to 2010 study period were included. The patients were aged 16 years to 90 years, sustained blunt torso trauma with hemorrhagic shock (systolic blood pressure < 90 mm Hg, base deficit ≥ 6 mEq/L, blood transfusion within the first 12 hours), but without severe head injury (motor Glasgow Coma Scale [GCS] score < 4). MOF temporal trends (Denver MOF score > 3) were adjusted for admission risk factors (age, sex, body max index, Injury Severity Score [ISS], systolic blood pressure, and base deficit) using survival analysis. RESULTS A total of 1,643 patients from four institutions were evaluated. MOF incidence decreased over time (from 17% in 2003–2004 to 9.8% in 2009–2010). MOF-related death rate (33% in 2003–2004 to 36% in 2009–2010), intensive care unit stay, and mechanical ventilation duration did not change over the study period. Adjustment for admission risk factors confirmed the crude trends. MOF patients required much longer ventilation and intensive care unit stay, compared with non-MOF patients. Most of the MOF-related deaths occurred within 2 days of the MOF diagnosis. Lung and cardiac dysfunctions became less frequent (57.6% to 50.8%, 20.9% to 12.5%, respectively), but kidney and liver failure rates did not change (10.1% to 12.5%, 15.2% to 14.1%). CONCLUSION Postinjury MOF remains a resource-intensive, morbid, and lethal condition. Lung injury is an enduring challenge and should be a research priority. The lack of outcome improvements suggests that reversing MOF is difficult and prevention is still the best strategy. LEVEL OF EVIDENCE Epidemiologic study, level III. PMID:24553523
Zhang, Xia; Li, Yuqian; Wang, Fang; Zang, Jianguo; Liu, Xiaotian; Zhang, Honglei; Yang, Kaili; Zhang, Gongyuan; Wang, Chongjian
2018-06-07
We examined the independent and cumulative associations of resting heart rate and pulse pressure with metabolic syndrome in Chinese rural population based on epidemiological research. A total of 38,708 participants were derived from the Henan Rural Cohort study. Restricted cubic splines and logistic regression model were used to estimate the odds ratios and 95% confidence intervals of metabolic syndrome risk in relation to resting heart rate and pulse pressure. After adjusting for potential confounders, the odds ratio (95% confidence intervals) of resting heart rate and pulse pressure in the highest quartile with the risk of metabolic syndrome were 1.59 (1.48-1.70) and1.81 (1.67-1.95), respectively. Simultaneously, the cumulative effect analysis indicated that the adjusted the odd ratio of resting heart rate and pulse pressure in the highest quartile was 2.89 (2.40-3.47). Furthermore, there was a significantly additive interaction between resting heart rate and pulse pressure on the risk of metabolic syndrome. Increased resting heart rate and pulse pressure are associated with the higher risk of metabolic syndrome as well as the influences of resting heart rate with pulse pressure might cumulatively increase the risk of metabolic syndrome. However, the potential clinical application remains to be determined. Copyright © 2018. Published by Elsevier B.V.
Scanning electron microscopy of high-pressure-frozen sea urchin embryos.
Walther, P; Chen, Y; Malecki, M; Zoran, S L; Schatten, G P; Pawley, J B
1993-12-01
High-pressure-freezing permits direct cryo-fixation of sea urchin embryos having a defined developmental state without the formation of large ice crystals. We have investigated preparation protocols for observing high-pressure-frozen and freeze-fractured samples in the scanning electron microscope. High-pressure-freezing was superior to other freezing protocols, because the whole bulk sample was reasonably well frozen and the overall three-dimensional shape of the embryos was well preserved. The samples were either dehydrated by freeze-substitution and critical-point-drying, or imaged in the partially hydrated state, using a cold stage in the SEM. During freeze-substitution the samples were stabilized by fixatives. The disadvantage of this method was that shrinking and extraction effects, caused by the removal of the water, could not be avoided. These disadvantages were avoided when the sample was imaged in the frozen-hydrated state using a cold-stage in the SEM. This would be the method of choice for morphometric studies. Frozen-hydrated samples, however, were very beam sensitive and many structures remained covered by the ice and were not visible. Frozen-hydrated samples were partially freeze-dried to make visible additional structures that had been covered by ice. However, this method also caused drying artifacts when too much water was removed.
Type 2 diabetes management in nurse-led primary healthcare settings in urban and rural Cameroon.
Kengne, Andre Pascal; Fezeu, Leopold; Sobngwi, Eugene; Awah, Paschal Kum; Aspray, Terence J; Unwin, Nigel C; Mbanya, Jean-Claude
2009-08-01
To implement a protocol-driven primary nurse-led care for type 2 diabetes in rural and urban Cameroon. We set-up three primary healthcare clinics in Yaounde (Capital city) and two in the Bafut rural health district. Participants were 225 (17% rural) patients with known or newly diagnosed type 2 diabetes, not requiring insulin, referred either from a baseline survey (38 patients, 17%), or secondarily attracted to the clinics. Protocol-driven glucose and blood pressure control were delivered by trained nurses. The main outcomes were trajectories of fasting capillary glucose and blood pressure indices, and differences in the mean levels between baseline and final visits. The total duration of follow-up was 1110 patient-months. During follow-up, there was a significant downward trend in fasting capillary glucose overall (p<0.001) and in most subgroups of participants. Between baseline and final visits, mean fasting capillary glucose dropped by 1.6 mmol/L (95% CI: 0.8-2.3; p< or =0.001). Among those with hypertension, blood pressure also decreased significantly for systolic and marginally for diastolic blood pressure. No major significant change was noticed for body weight. Nurses may be potential alternatives to improve access to diabetes care in settings where physicians are not available.
Improved rat liver decellularization by arterial perfusion under oscillating pressure conditions.
Struecker, Benjamin; Butter, Antje; Hillebrandt, Karl; Polenz, Dietrich; Reutzel-Selke, Anja; Tang, Peter; Lippert, Steffen; Leder, Anne; Rohn, Susanne; Geisel, Dominik; Denecke, Timm; Aliyev, Khalid; Jöhrens, Korinna; Raschzok, Nathanael; Neuhaus, Peter; Pratschke, Johann; Sauer, Igor M
2017-02-01
One approach of regenerative medicine to generate functional hepatic tissue in vitro is decellularization and recellularization, and several protocols for the decellularization of livers of different species have been published. This appears to be the first report on rat liver decellularization by perfusion under oscillating pressure conditions, intending to optimize microperfusion and minimize damage to the ECM. Four decellularization protocols were compared: perfusion via the portal vein (PV) or the hepatic artery (HA), with (+P) or without (-P) oscillating pressure conditions. All rat livers (n = 24) were perfused with 1% Triton X-100 and 1% sodium dodecyl sulphate, each for 90 min with a perfusion rate of 5 ml/min. Perfusion decellularization was observed macroscopically and the decellularized liver matrices were analysed by histology and biochemical analyses (e.g. levels of DNA, glycosaminoglycans and hepatocyte growth factor). Livers decellularized via the hepatic artery and under oscillating pressure showed a more homogeneous decellularization and less remaining DNA, compared with the livers of the other experimental groups. The novel decellularization method described is effective, quick (3 h) and gentle to the extracellular matrix and thus represents an improvement of existing methodology. Copyright © 2014 John Wiley & Sons, Ltd. Copyright © 2014 John Wiley & Sons, Ltd.
Mexican American Fathers' Occupational Conditions: Links to Family Members' Psychological Adjustment
ERIC Educational Resources Information Center
Crouter, Ann C.; Davis, Kelly D.; Updegraff, Kimberly; Delgado, Melissa; Fortner, Melissa
2006-01-01
To examine the implications of fathers' occupational conditions (i.e., income, work hours, shift work, pressure, workplace racism, and underemployment) for family members' psychological adjustment, home interviews were conducted with fathers, mothers, and two adolescent offspring in each of 218 Mexican American families. Results underscored the…
Southeast Asian International Students Adjusting to Jordanian Universities: Views from the Field
ERIC Educational Resources Information Center
Alazzi, Khaled; Al-Jarrah, Abdelnaser
2016-01-01
Using a qualitative research methodology, we interviewed 20 Southeast Asian undergraduate students from Malaysia and Indonesia attending universities in northern Jordan to identify any adjustment problems they may have been facing. These international students experienced pressure to succeed from their sponsoring agencies and families, a very…
Bires, Angela Macci; Lawson, Dori; Wasser, Thomas E; Raber-Baer, Donna
2013-12-01
Clinically valid cardiac evaluation via treadmill stress testing requires patients to achieve specific target heart rates and to successfully complete the cardiac examination. A comparison of the standard Bruce protocol and the ramped Bruce protocol was performed using data collected over a 1-y period from a targeted patient population with a body mass index (BMI) equal to or greater than 30 to determine which treadmill protocol provided more successful examination results. The functional capacity, metabolic equivalent units achieved, pressure rate product, and total time on the treadmill as measured for the obese patients were clinically valid and comparable to normal-weight and overweight patients (P < 0.001). Data gathered from each protocol demonstrated that the usage of the ramped Bruce protocol achieved more consistent results in comparison across all BMI groups in achieving 80%-85% of their age-predicted maximum heart rate. This study did not adequately establish that the ramped Bruce protocol was superior to the standard Bruce protocol for the examination of patients with a BMI equal to or greater than 30.
Ediani Machado, Michely; Tomazoni, Fernanda; Ruffo Ortiz, Fernanda; Ardenghi, Thiago Machado; Zanatta, Fabricio Batistin
2017-07-01
It is not clear how using partial-mouth periodontal examination (PMPE) protocols affects estimates of the association between gingival bleeding (GB) and oral health-related quality of life (OHRQoL). The aim of the present study is to assess impact of different PMPEs on the association between GB and OHRQoL in 12-year-old adolescents. A total of 1,134 adolescents were evaluated for clinical and subjective variables. GB was determined by full-mouth examination (FME) of six sites (disto-buccal [DB], mid-buccal [B], mesio-buccal [MB], disto-lingual [DL], mid-lingual, and mesio-lingual [ML]) and different PMPEs were calculated using a 15% cut-off point: 1) full-mouth (MB-B-DB/MB-B-DL); 2) two diagonal quadrants (six sites/MB-B-DB/MB-B-DL); 3) two randomly selected half-mouth quadrants (six sites/MB-B-DB/ MB-B-DL/MB-DB-ML-DL); and 4) the community periodontal index. OHRQoL was assessed using the Child Perceptions Questionnaire (CPQ 11-14 ). Adjusted negative binomial regression models were used to calculate the rate ratio of CPQ 11-14 scores for each PMPE. Adolescents with GB showed significantly poorer OHRQoL than their counterparts when FME was used. In contrast, more than half of PMPE protocols did not detect significant associations between GB and CPQ 11-14 scores in the adjusted analysis. Using PMPE to assess GB in adolescents significantly affects associations with OHRQoL outcomes, depending on the protocol used. PMPEs that evaluated MB-B-DL sites of randomly selected half-mouth quadrants (1 or 2 and 3 or 4) achieved results closer to those obtained with FME.
Eriksson, Bjorn O.; Docherty Skogh, Ann-Charlott; Sommar, Pehr; Hammarstedt, Lalle; Gahm, Caroline
2017-01-01
Background: The impact of preoperative radiotherapy on microvascular reconstructive surgery outcome has been a subject of debate. However, data are conflicting and often dependent on local treatment protocols. We have studied the effects of radiotherapy in a unique, single-center setting where a treatment protocol change was undertaken from pre- to postoperative radiotherapy administration for microsurgical head and neck reconstructions. Methods: A cohort study was conducted for 200 consecutive head and neck free flap cases, where 100 were operated on before and 100 after the treatment protocol adjustment in 2006. Only direct cancer reconstructions were included. Complication rates of anastomosis-related (flap necrosis) and flap bed–related (infection, fistula, and wound dehiscence) complications were compared between irradiated and nonirradiated patients. A multivariate analysis was performed to correct for treatment period. Results: One hundred twenty-six patients had received radiotherapy before reconstruction due to cases of cancer recurrence. There were no significant differences in demographic data or risk factors between irradiated and nonirradiated cases. Irradiated cases had a higher rate of both flap loss (9.5% versus 1.4%; P = 0.034) and flap bed–related complications (29% versus 13%; P = 0.014). However, after multivariate analysis, there was only a significant relationship between preoperative irradiation and infection (odds ratio = 2.51; P = 0.033) and fistula formation (odds ratio = 3.13; P = 0.034). Conclusions: The current single-center study clearly indicates that preoperative radiotherapy is a risk factor for both infection and fistula formation, most likely related to an impaired flap bed. We suggest postoperative radiotherapy administration whenever possible for oncological reasons, otherwise proper antibiotic cover and meticulous flap insetting to prevent radiation-related infection and fistula formation. PMID:28458967
Protocolized treatment is associated with decreased organ dysfunction in pediatric severe sepsis
Balamuth, Fran; Weiss, Scott L.; Fitzgerald, Julie C.; Hayes, Katie; Centkowski, Sierra; Chilutti, Marianne; Grundmeier, Robert W.; Lavelle, Jane; Alpern, Elizabeth R.
2016-01-01
Objective To determine whether treatment with a protocolized sepsis guideline in the emergency department (ED) was associated with a lower burden of organ dysfunction (OD) by hospital day 2 compared to non-protocolized usual care in pediatric patients with severe sepsis. Design Retrospective cohort study Setting Tertiary care children’s hospital from January 1, 2012–March 31, 2014. Measurements and Main Results Subjects with international consensus defined severe sepsis and pediatric intensive care unit (PICU) admission within 24 hours of ED arrival were included. The exposure was the use of a protocolized ED sepsis guideline. The primary outcome was complete resolution of OD by hospital day 2. One hundred eighty nine subjects were identified during the study period. Of these, 121 (64%) were treated with the protocolized ED guideline and 68 were not. There were no significant differences between the groups in age, sex, race, number of comorbid conditions, ED triage level, or OD on arrival to the ED. Patients treated with protocolized ED care were more likely to be free of OD on hospital day 2 after controlling for sex, comorbid condition, indwelling central venous catheter, PIM-2 score, and timing of antibiotics and intravenous fluids (adjusted OR 4.2, 95% CI 1.7, 10.4). Conclusions Use of a protocolized ED sepsis guideline was independently associated with resolution of OD by hospital day 2 compared to non-protocolized usual care. These data indicate that morbidity outcomes in children can be improved with the use of protocolized care. PMID:27455114
USDA-ARS?s Scientific Manuscript database
Objective: Absolute systolic blood pressure during exercise and a greater increase above baseline, or reactivity, in systolic blood pressure during psychological stress are correlated with an increased risk for cardiovascular disease. Most studies hypothesize that increased cardiovascular responses...