The effect of closed system suction on airway pressures when using the Servo 300 ventilator.
Frengley, R W; Closey, D N; Sleigh, J W; Torrance, J M
2001-12-01
To measure airway pressures during closed system suctioning with the ventilator set to three differing modes of ventilation. Closed system suctioning was conducted in 16 patients following cardiac surgery. Suctioning was performed using a 14 French catheter with a vacuum level of -500 cmH2O through an 8.0 mm internal diameter endotracheal tube. The lungs were mechanically ventilated with a Servo 300 ventilator set to one of three ventilation modes: volume-control, pressure-control or CPAP/pressure support. Airway pressures were measured via a 4 French electronic pressure transducer in both proximal and distal airways. Following insertion of the suction catheter, end-expiratory pressure increased significantly (p < 0.001) in both pressure-control and volume-control ventilation. This increase was greatest (p = 0.018) in volume-control mode (2.7 +/- 1.7 cmH2O). On performing a five second suction, airway pressure decreased in all modes, however the lowest airway pressure in volume-control mode (-4.9 +/- 4.0 cmH2O) was significantly (p = 0.001) less than the lowest airway pressure recorded in either pressure-control (0.8 +/- 1.9 cmH2O) or CPAP/pressure support (0.4 +/- 2.8 cmH2O) modes. In CPAP/pressure support mode, 13 of the 16 patients experienced a positive pressure 'breath' at the end of suctioning with airway pressures rising to 21 +/- 1.6 cmH2O. Closed system suctioning in volume control ventilation may result in elevations of end-expiratory pressure following catheter insertion and subatmospheric airway pressures during suctioning. Pressure control ventilation produces less elevation of end-expiratory pressure following catheter insertion and is less likely to be associated with subatmospheric airway pressures during suctioning. CPAP/pressure support has no effect on end-expiratory pressure following catheter insertion and subatmospheric airway pressures are largely avoided during suctioning.
Simulation Analysis of Computer-Controlled pressurization for Mixture Ratio Control
NASA Technical Reports Server (NTRS)
Alexander, Leslie A.; Bishop-Behel, Karen; Benfield, Michael P. J.; Kelley, Anthony; Woodcock, Gordon R.
2005-01-01
A procedural code (C++) simulation was developed to investigate potentials for mixture ratio control of pressure-fed spacecraft rocket propulsion systems by measuring propellant flows, tank liquid quantities, or both, and using feedback from these measurements to adjust propellant tank pressures to set the correct operating mixture ratio for minimum propellant residuals. The pressurization system eliminated mechanical regulators in favor of a computer-controlled, servo- driven throttling valve. We found that a quasi-steady state simulation (pressure and flow transients in the pressurization systems resulting from changes in flow control valve position are ignored) is adequate for this purpose. Monte-Carlo methods are used to obtain simulated statistics on propellant depletion. Mixture ratio control algorithms based on proportional-integral-differential (PID) controller methods were developed. These algorithms actually set target tank pressures; the tank pressures are controlled by another PID controller. Simulation indicates this approach can provide reductions in residual propellants.
Allsop, Jonathan E; Lawrence, Gavin P; Gray, Robert; Khan, Michael A
2017-09-01
Pressure to perform often results in decrements to both outcome accuracy and the kinematics of motor skills. Furthermore, this pressure-performance relationship is moderated by the amount of accumulated practice or the experience of the performer. However, the interactive effects of performance pressure and practice on the underlying processes of motor skills are far from clear. Movement execution involves both an offline pre-planning process and an online control process. The present experiment aimed to investigate the interaction between pressure and practice on these two motor control processes. Two groups of participants (control and pressure; N = 12 and 12, respectively) practiced a video aiming amplitude task and were transferred to either a non-pressure (control group) or a pressure condition (pressure group) both early and late in practice. Results revealed similar accuracy and movement kinematics between the control and pressure groups at early transfer. However, at late transfer, the introduction of pressure was associated with increased performance compared to control conditions. Analysis of kinematic variability throughout the movement suggested that the performance increase was due to participants adopting strategies to improve movement planning in response to pressure reducing the effectiveness of the online control system.
Capabilities of a New Pressure Controller for Gas-Controlled Heat Pipes
NASA Astrophysics Data System (ADS)
Giunta, S.; Merlone, A.; Marenco, S.; Marcarino, P.; Tiziani, A.
2008-10-01
Pressure control is used in many metrological applications and for the control of thermodynamic quantities. At the Italian National Research Institute of Metrology (INRiM), a new pressure controller has been designed and assembled, operating in the pressure range between 4 kPa and 400 kPa. This innovative instrument uses a commercial pressure transducer with a sensitivity of 10-4 and several electro-valves interposed among calibrated volumes of different dimensions in order to realize known ratios for very fine pressure changes. The device is provided with several circuits to drive the electro-valve actions, for signal processing and transmission, and for both manual and automatic control. Input/output peripherals, such as a 4 × 20 dot matrix display and a 4 × 4 keyboard, allow setting of the parameters and data visualization, while a remote control port allows interfacing with a computer. The operating principle of this pressure controller has been recently applied, with excellent results, to control the pressure in gas-controlled heat pipes by using a standard platinum resistance thermometer as a temperature/pressure sensor, achieving in this case a relative sensitivity better than 10-6 in pressure. Several tests were also made to control the pressure by means of a commercial sensor. The device, its main components, and its capabilities are here reported, together with application tests and results.
10 Ways to Control High Blood Pressure without Medication
10 ways to control high blood pressure without medication By making these 10 lifestyle changes, you can lower your blood pressure and reduce ... treating your high blood pressure. If you successfully control your blood pressure with a healthy lifestyle, you ...
Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas
2010-04-14
Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range
Pressurized tundish for controlling a continuous flow of molten metal
Lewis, Thomas W.; Hamill, Jr., Paul E.; Ozgu, Mustafa R.; Padfield, Ralph C.; Rego, Donovan N.; Brita, Guido P.
1990-01-01
A pressurized tundish for controlling a continous flow of molten metal characterized by having a pair of principal compartments, one being essentially unpressurized and receiving molten metal introduced thereto, and the other being adapted for maintaining a controlled gaseous pressure over the surface of the fluid metal therein, whereby, by controlling the pressure within the pressurized chamber, metal exiting from the tundish is made to flow continually and at a controlled rate.
Shuttle Orbiter Atmospheric Revitalization Pressure Control Subsystem
NASA Technical Reports Server (NTRS)
Walleshauser, J. J.; Ord, G. R.; Prince, R. N.
1982-01-01
The Atmospheric Revitalization Pressure Control Subsystem (ARPCS) provides oxygen partial pressure and total pressure control for the habitable atmosphere of the Shuttle for either a one atmosphere environment or an emergency 8 PSIA mode. It consists of a Supply Panel, Control Panel, Cabin Pressure Relief Valves and Electronic Controllers. The panels control and monitor the oxygen and nitrogen supplies. The cabin pressure relief valves protect the habitable environment from overpressurization. Electronic controllers provide proper mixing of the two gases. This paper describes the ARPCS, addresses the changes in hardware that have occurred since the inception of the program; the performance of this subsystem during STS-1 and STS-2; and discusses future operation modes.
Research on pressure control of pressurizer in pressurized water reactor nuclear power plant
NASA Astrophysics Data System (ADS)
Dai, Ling; Yang, Xuhong; Liu, Gang; Ye, Jianhua; Qian, Hong; Xue, Yang
2010-07-01
Pressurizer is one of the most important components in the nuclear reactor system. Its function is to keep the pressure of the primary circuit. It can prevent shutdown of the system from the reactor accident under the normal transient state while keeping the setting value in the normal run-time. This paper is mainly research on the pressure system which is running in the Daya Bay Nuclear Power Plant. A conventional PID controller and a fuzzy controller are designed through analyzing the dynamic characteristics and calculating the transfer function. Then a fuzzy PID controller is designed by analyzing the results of two controllers. The fuzzy PID controller achieves the optimal control system finally.
Pressurized tundish for controlling a continuous flow of molten metal
Lewis, T.W.; Hamill, P.E. Jr.; Ozgu, M.R.; Padfield, R.C.; Rego, D.N.; Brita, G.P.
1990-07-24
A pressurized tundish for controlling a continuous flow of molten metal is characterized by having a pair of principal compartments, one being essentially unpressurized and receiving molten metal introduced thereto, and the other being adapted for maintaining a controlled gaseous pressure over the surface of the fluid metal therein, whereby, by controlling the pressure within the pressurized chamber, metal exiting from the tundish is made to flow continually and at a controlled rate. 1 fig.
46 CFR 62.35-50 - Tabulated monitoring and safety control requirements for specific systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... lubrication Pressure Low Main propulsion, controllable pitch propeller Hydraulic oil Pressure High, Low... ......ditto (3) Trial for ignition Status Failure ......ditto Control power Available (pressure) Failure (low... Activated Starting power Pressure (voltage) Low Limit (2) Location in control Status Override (6) Shaft...
46 CFR 62.35-50 - Tabulated monitoring and safety control requirements for specific systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... lubrication Pressure Low Main propulsion, controllable pitch propeller Hydraulic oil Pressure High, Low... ......ditto (3) Trial for ignition Status Failure ......ditto Control power Available (pressure) Failure (low... Activated Starting power Pressure (voltage) Low Limit (2) Location in control Status Override (6) Shaft...
46 CFR 62.35-50 - Tabulated monitoring and safety control requirements for specific systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... lubrication Pressure Low Main propulsion, controllable pitch propeller Hydraulic oil Pressure High, Low... ......ditto (3) Trial for ignition Status Failure ......ditto Control power Available (pressure) Failure (low... Activated Starting power Pressure (voltage) Low Limit (2) Location in control Status Override (6) Shaft...
46 CFR 154.701 - Cargo pressure and temperature control: General.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Cargo pressure and temperature control: General. 154.701... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.701 Cargo pressure and temperature control: General...
46 CFR 154.701 - Cargo pressure and temperature control: General.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Cargo pressure and temperature control: General. 154.701... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.701 Cargo pressure and temperature control: General...
46 CFR 154.701 - Cargo pressure and temperature control: General.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Cargo pressure and temperature control: General. 154.701... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.701 Cargo pressure and temperature control: General...
46 CFR 154.701 - Cargo pressure and temperature control: General.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pressure and temperature control: General. 154.701... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.701 Cargo pressure and temperature control: General...
46 CFR 154.701 - Cargo pressure and temperature control: General.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Cargo pressure and temperature control: General. 154.701... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.701 Cargo pressure and temperature control: General...
NASA Technical Reports Server (NTRS)
Kassemi, Mohammad; Hylton, Sonya; Kartizova, Olga
2013-01-01
The Zero-Boil-Off Tank (ZBOT) Experiment is a small-scale experiment that uses a transparent ventless Dewar and a transparent simulant phase-change fluid to study sealed tank pressurization and pressure control with applications to on-surface and in-orbit storage of propellant cryogens. The experiment will be carried out under microgravity conditions aboard the International Space Station in the 2014 timeframe. This paper presents preliminary results from ZBOT's ground-based research that focuses on the effects of residual noncondensable gases in the ullage on both pressurization and pressure reduction trends in the sealed Dewar. Tank pressurization is accomplished through heating of the test cell wall in the wetted and un-wetted regions simultaneously or separately. Pressure control is established through mixing and destratification of the bulk liquid using a temperature controlled forced jet flow with different degrees of liquid jet subcooling. A Two-Dimensional axisymmetric two-phase CFD model for tank pressurization and pressure control is also presented. Numerical prediction of the model are compared to experimental 1g results to both validate the model and also indicate the effect of the noncondensable gas on evolution of pressure and temperature distributions in the ullage during pressurization and pressure control. Microgravity simulations case studies are also performed using the validated model to underscore and delineate the profound effect of the noncondensables on condensation rates and interfacial temperature distributions with serious implications for tank pressure control in reduced gravity.
CDC Vital Signs: Blood Pressure Control -- Helping Patients Take Their Medicine
... Kit Read the MMWR Science Clips Blood Pressure Control Helping Patients Take Their Medicine Language: English (US) ... pressure and only about half have it under control (less than 140/90 mmHg). Blood pressure medicine ( ...
Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System
NASA Astrophysics Data System (ADS)
Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren
2017-11-01
The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.
System for throttling and compensation for variable feedstock properties
Meyer, J. W.
1981-05-05
Apparatus is shown for adjusting the feed rate of pulverized feed material into a pressurized container. The apparatus also has utility for compensating for variations in the permeability of the feed material. A rotor that includes sprues with provision for controlling the pressure distribution along the sprues is located within the pressurized container. The rotor hub is connected to a drive means and a material supply means which extend through the wall of the container. A line for controlling pressure along the sprues by gas injection is connected to a chamber between sections of the sprue for controlling gas pressure at that point. The gas pressure control line is connected to a pressurized gas source and a control system external to the rotor. 10 figs.
System for throttling and compensation for variable feedstock properties
Meyer, John W.
1981-01-01
Apparatus is shown for adjusting the feed rate of pulverized feed material into a pressurized container. The apparatus also has utility for compensating for variations in the permeability of the feed material. A rotor that includes sprues with provision for controlling the pressure distribution along the sprues is located within the pressurized container. The rotor hub is connected to a drive means and a material supply means which extend through the wall of the container. A line for controlling pressure along the sprues by gas injection is connected to a chamber between sections of the sprue for controlling gas pressure at that point. The gas pressure control line is connected to a pressurized gas source and a control system external to the rotor.
Importance of pressure reducing valves (PRVs) in water supply networks.
NASA Astrophysics Data System (ADS)
Signoreti, R. O. S.; Camargo, R. Z.; Canno, L. M.; Pires, M. S. G.; Ribeiro, L. C. L. J.
2016-08-01
Challenged with the high rate of leakage from water supply systems, these managers are committed to identify control mechanisms. In order to standardize and control the pressure Pressure Reducing Valves (VRP) are installed in the supply network, shown to be more effective and provide a faster return for the actual loss control measures. It is known that the control pressure is while controlling the occurrence of leakage. Usually the network is sectored in areas defined by pressure levels according to its topography, once inserted the VRP in the same system will limit the downstream pressure. This work aims to show the importance of VRP as loss reduction for tool.
Controlling the vapor pressure of a mercury lamp
Grossman, Mark W.; George, William A.
1988-01-01
The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.
Delgado, Jose; Jacobs, Elizabeth A; Lackland, Daniel T; Evans, Denis A; de Leon, Carlos F Mendes
2012-11-01
Cardiovascular disease is the main cause of death in older adults. Uncontrolled blood pressure is an important risk factor for cardiovascular disease. African Americans have poorer blood pressure control than non-Hispanic whites. Little is known about whether this difference persists in older ages or the factors that contribute to this racial gap. Data were obtained from participants of the Chicago Health and Aging Program. Blood pressure control was defined according to JNC-7 criteria. Univariate chi-square analyses were used to determine racial differences in hypertension and blood pressure control, whereas sequential multivariate logistic regression models were used to determine the effect of race on blood pressure control. African Americans had a higher prevalence of hypertension (74% vs 63%; p < .001), higher awareness of hypertension (81% vs 72%; p < .001), and poorer blood pressure control (45% vs 51%, p < .001) than non-Hispanic whites. Racial differences in blood pressure control persisted after adjustment for socioeconomic status, medical conditions, obesity, and use of antihypertensive medications (odds ratio = 0.84, 95% confidence interval = 0.70-0.94). From 1993 to 2008, blood pressure control improved more among non-Hispanic whites than among African Americans. Racial differences in blood pressure control in older adults were not explained by socioeconomic status. The racial disparity in the prevalence and control of hypertension remained consistent for older hypertensive individuals eligible for Medicare. Although the rates of hypertension control improved for both racial groups, the improvement was greater among whites, thus widening the gap in this older population at high risk for cardiovascular disease.
Vanadium hydride deuterium-tritium generator
Christensen, Leslie D.
1982-01-01
A pressure controlled vanadium hydride gas generator to provide deuterium-tritium gas in a series of pressure increments. A high pressure chamber filled with vanadium-deuterium-tritium hydride is surrounded by a heater which controls the hydride temperature. The heater is actuated by a power controller which responds to the difference signal between the actual pressure signal and a programmed pressure signal.
49 CFR 192.197 - Control of the pressure of gas delivered from high-pressure distribution systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Control of the pressure of gas delivered from high-pressure distribution systems. 192.197 Section 192.197 Transportation Other Regulations Relating to... STANDARDS Design of Pipeline Components § 192.197 Control of the pressure of gas delivered from high...
Power control system for a hot gas engine
Berntell, John O.
1986-01-01
A power control system for a hot gas engine of the type in which the power output is controlled by varying the mean pressure of the working gas charge in the engine has according to the present invention been provided with two working gas reservoirs at substantially different pressure levels. At working gas pressures below the lower of said levels the high pressure gas reservoir is cut out from the control system, and at higher pressures the low pressure gas reservoir is cut out from the system, thereby enabling a single one-stage compressor to handle gas within a wide pressure range at a low compression ratio.
A Pressure Control Method for Emulsion Pump Station Based on Elman Neural Network
Tan, Chao; Qi, Nan; Yao, Xingang; Wang, Zhongbin; Si, Lei
2015-01-01
In order to realize pressure control of emulsion pump station which is key equipment of coal mine in the safety production, the control requirements were analyzed and a pressure control method based on Elman neural network was proposed. The key techniques such as system framework, pressure prediction model, pressure control model, and the flowchart of proposed approach were presented. Finally, a simulation example was carried out and comparison results indicated that the proposed approach was feasible and efficient and outperformed others. PMID:25861253
Pressure-Aware Control Layer Optimization for Flow-Based Microfluidic Biochips.
Wang, Qin; Xu, Yue; Zuo, Shiliang; Yao, Hailong; Ho, Tsung-Yi; Li, Bing; Schlichtmann, Ulf; Cai, Yici
2017-12-01
Flow-based microfluidic biochips are attracting increasing attention with successful biomedical applications. One critical issue with flow-based microfluidic biochips is the large number of microvalves that require peripheral control pins. Even using the broadcasting addressing scheme, i.e., one control pin controls multiple microvalves simultaneously, thousands of microvalves would still require hundreds of control prins, which is unrealistic. To address this critical challenge in control scalability, the control-layer multiplexer is introduced to effectively reduce the number of control pins into log scale of the number of microvalves. There are two practical design issues with the control-layer multiplexer: (1) the reliability issue caused by the frequent control-valve switching, and (2) the pressure degradation problem caused by the control-valve switching without pressure refreshing from the pressure source. This paper addresses these two design issues by the proposed Hamming-distance-based switching sequence optimization method and the XOR-based pressure refreshing method. Simulation results demonstrate the effectiveness and efficiency of the proposed methods with an average 77.2% (maximum 89.6%) improvement in total pressure refreshing cost, and an average 88.5% (maximum 90.0%) improvement in pressure deviation.
Functional Changes of Diaphragm Type Shunt Valves Induced by Pressure Pulsation
NASA Astrophysics Data System (ADS)
Lee, Chong-Sun; Suh, Chang-Min; Ra, Young-Shin
Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of pressure pulsation on their flow control characteristics. Our focus was on flow dynamic and functional changes of the small and thin diaphragms in the valves that serve as the main flow control mechanism and are made from silicone elastomer. Firstly, pressure-flow control curves were compared under pulsed and steady flow (without pulsation) conditions. Secondly, functional changes of the valves were tested after a long-term continuous pulsation with a peristaltic pump. Thirdly, flushing procedures selectively conducted by neurosurgeons were simulated with a fingertip pressed on the dome of the valves. As 20cc/hr of flow rate was adjusted at a constant pressure, application of 40mmH2O of pressure pulse increased flow rate through shunt valves more than 60%. As a 90cm length silicone catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to 17.5%. Pressure-flow control characteristics of some valves showed significant changes after twenty-eight days of pressure pulsation at 1.0 Hz under 50.0cc/hr of flow rate. Flushing simulation resulted in temporary decrease in the pressure level. It took three hours to fully recover the normal pressure-flow control characteristics after the flushing. Our results suggest that shunt valves with a thin elastic diaphragm as the main flow control mechanism are sensitive to intracranial pressure pulsation or pressure spikes enough to change their pressure-flow control characteristics.
The pressure control technology of the active stressed lap
NASA Astrophysics Data System (ADS)
Li, Ying; Wang, Daxing
2010-10-01
The active stressed lap polishing technology is a kind of new polishing technology that can actively deform the lap surface to become an off-axis asphere according to different lap position on mirror surface and different angle of lap. The pressure of the lap on the mirror is an important factor affecting the grinding efficiency of the optics mirror. The active stressed lap technology using dynamic pressure control solution in the process of polishing astronomical Aspheric Mirror with faster asphericity will provide the advantage like high polishing speed and natural smooth, etc. This article puts emphases on the pressure control technology of the active stressed lap technology. It requires that the active stressed lap keeps symmetrical vertical compression on the mirrors in the process of grinding mirrors. With a background of an active stressed lap 450mm in diameter, this article gives an outline of the pressure control organization, analyzes the principle of pressure control and proposes the limitations of the present pressure control organization and the relevant solutions, designs a digital pressure controller with C32-bit RISC embedded and gives the relevant experimental test result finally.
Vanadium hydride deuterium-tritium generator
Christensen, L.D.
1980-03-13
A pressure controlled vanadium hydride gas generator was designed to provide deuterium-tritium gas in a series of pressure increments. A high pressure chamber filled with vanadium-deuterium-tritium hydride is surrounded by a heater which controls the hydride temperature. The heater is actuated by a power controller which responds to the difference signal between the actual pressure signal and a programmed pressure signal.
Darrah, Shaun D; Dicianno, Brad E; Berthold, Justin; McCoy, Andrew; Haas, Matthew; Cooper, Rory A
2016-01-01
To determine whether sledge hockey players with physical disability have higher average seated pressures compared to non-disabled controls. Fifteen age-matched controls without physical disability and 15 experimental participants with physical disability were studied using a pressure mapping device to determine risk for skin pressure ulceration and the impact of cushioning and knee angle positioning on seated pressure distributions. Regardless of participant group, cushioning, or knee angle, average seated pressures exceeded clinically acceptable seated pressures. Controls had significantly higher average seated pressures than the disability group when knees were flexed, both with the cushion (p = 0.013) and without (p = 0.015). Knee extension showed significantly lower average pressures in controls, both with the cushion (p < 0.001) and without (p < 0.001). Placement of the cushion resulted in significantly lower average pressure in controls when knees were extended (p = 0.024) but not when flexed (p = 0.248). Placement of the cushion resulted in no difference in pressure (p = 0.443) in the disability group. Pressures recorded indicate high risk for skin ulceration. Cushioning was effective only in the control group with knees extended. That knee extension significantly lowered average seated pressures is important, as many sledge hockey players utilize positioning with larger knee flexion angles. Implications for Rehabilitation Ice sledge hockey is a fast growing adaptive sport. Adaptive sports have been associated with several positive improvements in overall health and quality of life, though may be putting players at risk for skin ulceration. Measured static seated pressure in sledges greatly exceeds current clinically accepted clinical guidelines. With modern improvements in wheelchair pressure relief/cushioning there are potential methods for improvement of elevated seated pressure in ice hockey sledges.
Fortescue, P.; Nicoll, D.
1962-04-24
A control system employed with a high pressure gas cooled reactor in which a control rod is positioned for upward and downward movement into the neutron field from a position beneath the reactor is described. The control rod is positioned by a coupled piston cylinder releasably coupled to a power drive means and the pressurized coolant is directed against the lower side of the piston. The coolant pressure is offset by a higher fiuid pressure applied to the upper surface of the piston and means are provided for releasing the higher pressure on the upper side of the piston so that the pressure of the coolant drives the piston upwardly, forcing the coupled control rod into the ncutron field of the reactor. (AEC)
Controlling the vapor pressure of a mercury lamp
Grossman, M.W.; George, W.A.
1988-05-24
The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.
Provol, Steve J.; Russell, David B.; Isaksson, Matti J.
1994-01-01
A power plant having a system for converting coal to power in a gas turbine comprises a coal fed pressurized circulating bed for converting coal to pressurized gases, a gas turbine having a compressor for pressurizing air for the pressurized circulating bed and expander for receiving and expanding hot combustion gases for powering a generator, a first fast acting valve for controlling the pressurized air, a second fast acting valve means for controlling pressurized gas from the compressor to the expander.
40 CFR 60.5430 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... control vessels, bottoms receivers or knockout vessels. (3) Pressure vessels designed to operate in excess... supply natural gas to the process control device (e.g., level control, temperature control, pressure control) where the supply gas pressure is modulated by the process condition, and then flows to the valve...
ERIC Educational Resources Information Center
National Institutes of Health (DHEW), Bethesda, MD. High Blood Pressure Information Center.
This curriculum guide on high blood pressure (hypertension) for nursing educators has five sections: (1) Introduction and Objectives provides information regarding the establishment and objectives of the National Task Force on the Role of Nursing in High Blood Pressure Control and briefly discusses nursing's role in hypertension control; (2) Goals…
Saindane, A M; Qiu, D; Oshinski, J N; Newman, N J; Biousse, V; Bruce, B B; Holbrook, J F; Dale, B M; Zhong, X
2018-02-01
Intracranial pressure is estimated invasively by using lumbar puncture with CSF opening pressure measurement. This study evaluated displacement encoding with stimulated echoes (DENSE), an MR imaging technique highly sensitive to brain motion, as a noninvasive means of assessing intracranial pressure status. Nine patients with suspected elevated intracranial pressure and 9 healthy control subjects were included in this prospective study. Controls underwent DENSE MR imaging through the midsagittal brain. Patients underwent DENSE MR imaging followed immediately by lumbar puncture with opening pressure measurement, CSF removal, closing pressure measurement, and immediate repeat DENSE MR imaging. Phase-reconstructed images were processed producing displacement maps, and pontine displacement was calculated. Patient data were analyzed to determine the effects of measured pressure on pontine displacement. Patient and control data were analyzed to assess the effects of clinical status (pre-lumbar puncture, post-lumbar puncture, or control) on pontine displacement. Patients demonstrated imaging findings suggesting chronically elevated intracranial pressure, whereas healthy control volunteers demonstrated no imaging abnormalities. All patients had elevated opening pressure (median, 36.0 cm water), decreased by the removal of CSF to a median closing pressure of 17.0 cm water. Patients pre-lumbar puncture had significantly smaller pontine displacement than they did post-lumbar puncture after CSF pressure reduction ( P = .001) and compared with controls ( P = .01). Post-lumbar puncture patients had statistically similar pontine displacements to controls. Measured CSF pressure in patients pre- and post-lumbar puncture correlated significantly with pontine displacement ( r = 0.49; P = .04). This study establishes a relationship between pontine displacement from DENSE MR imaging and measured pressure obtained contemporaneously by lumbar puncture, providing a method to noninvasively assess intracranial pressure status in idiopathic intracranial hypertension. © 2018 by American Journal of Neuroradiology.
Gunningberg, Lena; Sedin, Inga-Maj; Andersson, Sara; Pingel, Ronnie
2017-07-01
Pressure ulcers cause suffering to patients and costs to society. Reducing pressure at the interface between the patient's body and the support surface is a valid clinical intervention for reducing the risk of pressure ulcers. However, studies have shown that knowledge of how to reduce pressure and shear and to prevent pressure ulcers is lacking. To evaluate the effect of a pressure mapping system on pressure ulcer prevalence and incidence in a hospital setting. Pragmatic randomised controlled trial. A geriatric/internal medical ward with 26 beds in a Swedish university hospital. 190 patients were recruited (intervention: n=91; control: n=99) over a period of 9 months. Patients were eligible if they were over 50 years old, admitted to the ward between Sunday 4pm and Friday 4pm, and expected to stay in the ward ≥3 days. The continuous bedside pressure mapping system displays the patient's pressure points in real-time colour imagery showing how pressure is distributed at the body-mat interface. The system gives immediate feedback to staff about the patient's pressure points, facilitating preventive interventions related to repositioning. It was used from admittance to discharge from the ward (or 14 days at most). Both intervention and control groups received standard pressure ulcer prevention care. No significant difference in the prevalence and incidence of pressure ulcers was shown between intervention and control groups. The prevalence of pressure ulcers in the intervention group was 24.2% on day 1 and 28.2% on day 14. In the control group the corresponding numbers were 18.2% and 23.8%. Seven of 69 patients (10.1%) in the intervention group and seven of 81 patients (8.6%) in the control group who had no pressure ulcers on admission developed category 1 and category 2 ulcers during their hospital stay. The incidence rate ratio between the intervention and control groups was 1.13 (95% CI: 0.34-3.79). This study failed to demonstrate a beneficial effect of a pressure mapping system on pressure ulcer prevalence and incidence. However, the study could have increased staff awareness and focus on pressure ulcer prevention, thus affecting the prevalence and incidence of pressure ulcers in a positive way in both study groups. It is important to further investigate the experience of the multidisciplinary team and the patients regarding their use of the pressure mapping system, as well as strengths and weaknesses of the system. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pahari, S.; Hajela, S.; Rammohan, H. P.
2012-07-01
700 MWe Indian Pressurized Heavy Water Reactor (IPHWR) is horizontal channel type reactor with partial boiling at channel outlet. Due to boiling, it has a large volume of vapor present in the primary loops. It has two primary loops connected with the help of pressurizer surge line. The pressurizer has a large capacity and is partly filled by liquid and partly by vapor. Large vapor volume improves compressibility of the system. During turbine trip or load rejection, pressure builds up in Steam Generator (SG). This leads to pressurization of Primary Heat Transport System (PHTS). To control pressurization of SG andmore » PHTS, around 70% of the steam generated in SG is dumped into the condenser by opening Condenser Steam Dump Valves (CSDVs) and rest of the steam is released to the atmosphere by opening Atmospheric Steam Discharge Valves (ASDVs) immediately after sensing the event. This is accomplished by adding anticipatory signal to the output of SG pressure controller. Anticipatory signal is proportional to the thermal power of reactor and the proportionality constant is set so that SG pressure controller's output jacks up to ASDV opening range when operating at 100% FP. To simulate this behavior for 700 MWe IPHWR, Primary and secondary heat transport system is modeled. SG pressure control and other process control program have also been modeled to capture overall plant dynamics. Analysis has been carried out with 3-D neutron kinetics coupled thermal hydraulic computer code ATMIKA.T to evaluate the effect of the anticipatory signal on PHT pressure and over all plant dynamics during turbine trip in 700 MWe IPHWR. This paper brings out the results of the analysis with and without considering anticipatory signal in SG pressure control program during turbine trip. (authors)« less
Esselman, W.H.; Kaplan, G.M.
1961-06-20
The control of pressure in pressurized liquid systems, especially a pressurized liquid reactor system, may be achieved by providing a bias circuit or loop across a closed loop having a flow restriction means in the form of an orifice, a storage tank, and a pump connected in series. The subject invention is advantageously utilized where control of a reactor can be achieved by response to the temperature and pressure of the primary cooling system.
Servo Controlled Variable Pressure Modification to Space Shuttle Hydraulic Pump
NASA Technical Reports Server (NTRS)
Kouns, H. H.
1983-01-01
Engineering drawings show modifications made to the constant pressure control of the model AP27V-7 hydraulic pump to an electrically controlled variable pressure setting compensator. A hanger position indicator was included for continuously monitoring hanger angle. A simplex servo driver was furnished for controlling the pressure setting servovalve. Calibration of the rotary variable displacement transducer is described as well as pump performance and response characteristics.
The Impact of Social Pressure and Monetary Incentive on Cognitive Control.
Ličen, Mina; Hartmann, Frank; Repovš, Grega; Slapničar, Sergeja
2016-01-01
We compare the effects of two prominent organizational control mechanisms-social pressure and monetary incentive-on cognitive control. Cognitive control underlies the human ability to regulate thoughts and actions in the pursuit of behavioral goals. Previous studies show that monetary incentives can contribute to goal-oriented behavior by activating proactive control. There is, however, much less evidence of how social pressure affects cognitive control and task performance. In a within-subject experimental design, we tested 47 subjects performing the AX-CPT task to compare the activation of cognitive control modes under social pressure and monetary incentive beyond mere instructions to perform better. Our results indicate that instructing participants to improve their performance on its own leads to a significant shift from a reactive to a proactive control mode and that both social pressure and monetary incentive further enhance performance.
Kawanishi, Makoto; Oura, Atsuhiro; Furukawa, Katsuko; Fukubayashi, Toru; Nakamura, Kozo; Tateishi, Tetsuya; Ushida, Takashi
2007-05-01
Hydrostatic pressure is one of the most frequently used mechanical stimuli in chondrocyte experiments. A variety of hydrostatic pressure loading devices have been used in cartilage cell experiments. However, no gas-controlled system with other than a low pressure load was used up to this time. Hence we used a polyolefin bag from which gas penetration was confirmed. Chondrocytes were extracted from bovine normal knee joint cartilage. After 3 passages, dedifferentiated chondrocytes were applied to form a pellet. These pellets were cultured in chemically defined serum-free medium with ITS+Premix for 3 days. Then 5 MPa of cyclic hydrostatic pressure was applied at 0.5 Hz for 4 h per day for 4 days. Semiquantitative reverse transcriptase-polymerase chain reaction showed a 5-fold increase in the levels of aggrecan mRNA due to cyclic hydrostatic pressure load (p<0.01). Type II collagen mRNA levels were also upregulated 4-fold by a cyclic hydrostatic pressure load (p<0.01). Type I collagen mRNA levels were similarly reduced in the cyclic hydrostatic pressure load group and in the control group. The partial oxygen pressure (PO2) and partial carbon dioxide pressure (PCO2) of the medium in the bag reached equilibrium in 24 h, and no significant change was observed for 3 days afterwards. PO2 and PCO2 were very well controlled. The loaded pellet showed better safranin O/fast green staining than did the control pellet. Metachromatic staining by Alcian blue staining was found to be stronger in the loaded than in the control pellets. The extracellular matrices excretion of loaded pellets was higher than that of control pellets. These results suggest that gas-controlled cyclic hydrostatic pressure enhanced the cartilaginous matrix formation of dedifferentiated cells differentiated in vitro.
Controlled differential pressure system for an enhanced fluid blending apparatus
Hallman, Jr., Russell Louis
2009-02-24
A system and method for producing a controlled blend of two or more fluids. Thermally-induced permeation through a permeable tube is used to mix a first fluid from outside the tube with a second fluid flowing through the tube. Mixture ratios may be controlled by adjusting the temperature of the first fluid or by adjusting the pressure drop through the permeable tube. The combination of a back pressure control valve and a differential regulator is used to control the output pressure of the blended fluid. The combination of the back pressure control valve and differential regulator provides superior flow control of the second dry gas. A valve manifold system may be used to mix multiple fluids, and to adjust the volume of blended fluid produced, and to further modify the mixture ratio.
Parasitic load control system for exhaust temperature control
Strauser, Aaron D.; Coleman, Gerald N.; Coldren, Dana R.
2009-04-28
A parasitic load control system is provided. The system may include an exhaust producing engine and a fuel pumping mechanism configured to pressurize fuel in a pressure chamber. The system may also include an injection valve configured to cause fuel pressure to build within the pressure chamber when in a first position and allow injection of fuel from the pressure chamber into one or more combustion chambers of the engine when in a second position. The system may further include a controller configured to independently regulate the pressure in the pressure chamber and the injection of fuel into the one or more combustion chambers, to increase a load on the fuel pumping mechanism, increasing parasitic load on the engine, thereby increasing a temperature of the exhaust produced by the engine.
Luo, Hong-Ji; Lin, Shi-Xiang; Wu, Shyi-Kuen; Tsai, Mei-Wun; Lee, Shwn-Jen
2017-01-01
Postural rehabilitation emphasizing on motor control training of segmental spinal movements has been proposed to effectively reduce the scoliotic spinal deformities in adolescent idiopathic scoliosis (AIS). However, information regarding the impairments of segmental spinal movement control involving segmental spinal stabilizers in adolescent idiopathic scoliosis remains limited. Examination of segmental spinal movement control may provide a window for investigating the features of impaired movement control specific to spinal segments that may assist in the development of physiotherapeutic management of AIS. To compare segmental spinal movement control in adolescents with and without idiopathic scoliosis using modified pressure biofeedback unit. Segmental spinal movement control was assessed in twenty adolescents with idiopathic scoliosis (AISG) and twenty healthy adolescents (CG) using a modified pressure biofeedback unit. Participants performed segmental spinal movements that primarily involved segmental spinal stabilizing muscles with graded and sustained muscle contraction against/off a pressure cuff from baseline to target pressures and then maintained for 1 min. Pressure data during the 1-minute maintenance phase were collected for further analysis. Pressure deviation were calculated and compared between groups. The AISG had significantly greater pressure deviations for all segmental spinal movements of cervical, thoracic, and lumbar spine than the CG. Pressure biofeedback unit was feasible for assessing segmental spinal movement control in AIS. AISG exhibited poorer ability to grade and sustain muscle activities for local movements of cervical, thoracic, and lumbar spine, suggesting motor control training of segmental spinal movements involving segmental spinal stabilizing muscles on frontal, sagittal, and transverse planes were required.
A model of psychosocial and cultural antecedents of blood pressure control.
Bosworth, Hayden B.; Oddone, Eugene Z.
2002-01-01
Hypertension is a major modifiable risk factor for stroke, congestive heart failure, and end-stage renal disease. Hypertension is particularly prevalent and deadly among African Americans. Effective treatment for hypertension has been available for decades, yet only one fourth of all individuals have their blood pressure under control. Despite the potential impact of hypertension, interventions to improve control have had limited success. We present a model of how to understand antecedents of blood pressure control according to three interrelated categories: patient characteristics, social and cultural environment, and medical environment. This theoretical paper was conducted using a literature review and a model to explain psychosocial antecedents of blood pressure control is presented. We conclude that improved understanding of important antecedents of blood pressure control coupled with technological advances, such as tailored interventions, provide clinicians with a tool that may lead to improved blood pressure control. These interventions will require the involvement of clinicians and consideration of sociocultural factors to be successful. PMID:11991336
Effect of Sahaja yoga meditation on quality of life, anxiety, and blood pressure control.
Chung, Sheng-Chia; Brooks, Maria M; Rai, Madhur; Balk, Judith L; Rai, Sandeep
2012-06-01
The present study investigates the effect of Sahaja yoga meditation on quality of life, anxiety, and blood pressure control. The prospective observational cohort study enrolled two study groups: those receiving treatment from the International Sahaja Yoga Research and Health Center (meditation group) and those receiving treatment from the Mahatma Gandhi Mission Hospital (control group). Researchers measured quality of life, anxiety, and blood pressure before and after treatment. Sixty-seven (67) participants in the meditation group and 62 participants in the control group completed the study. The two groups were comparable in demographic and clinical characteristics. At baseline, the meditation group had higher quality of life (p<0.001) than controls but similar anxiety level (p=0.74) to controls. Within-group pre- versus post-treatment comparisons showed significant improvement in quality of life, anxiety, and blood pressure in the meditation group (p<0.001), while in controls, quality of life deteriorated and there was no improvement in blood pressure. The improvement in quality of life, anxiety reduction, and blood pressure control was greater in the meditation group. The beneficial effect of meditation remained significant after adjusting for confounders. Meditation treatment was associated with significant improvements in quality of life, anxiety reduction, and blood pressure control.
NASA Technical Reports Server (NTRS)
1986-01-01
Engineering Development Laboratory developed a system for the cardiovascular study of weightless astronauts. This was designed to aid people with congestive heart failure and diabetes. While in space, astronauts' blood pressure rises, heart rate becomes unstable, and there are sometimes postflight lightheadedness or blackouts. The Baro-Cuff studies the resetting of blood pressure. When a silicone rubber chamber is strapped to the neck, the Baro-Cuff stimulates the carotid arteries by electronically controlled pressure application. Blood pressure controls in patients may be studied.
NASA Technical Reports Server (NTRS)
Kassemi, Mohammad; Hylton, Sonya; Kartuzova, Olga
2017-01-01
Integral to all phases of NASA's projected space and planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. Cryogen vaporization due to heat leaks into the tank from its surroundings and support structure can cause self-pressurization relieved through venting. This has led to a desire to develop innovative pressure control designs based on mixing of the bulk tank fluid together with some form of active or passive cooling to allow storage of the cryogenic fluid with zero or reduced boil-off. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small scale tank pressurization and pressure control experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. The hardware for ZBOT-1 flew to ISS on the OA-7 flight in April 2017 and operations are planned to begin in September 2017, encompassing more than 90 tests. This paper presents preliminary results from ZBOT's ground-based research delineating both pressurization and pressure reduction trends in the sealed test tank. Tank self-pressurization tests are conducted under three modes: VJ heating, strip heating and simultaneous VJ and strip heating in attempt to simulate heat leaks from the environment, the support structure and both. The jet mixing pressure control studies are performed either from an elevated uniform temperature condition or from thermally stratified conditions following a self-pressurization run. Jet flow rates are varied from 2-25 cm/s spanning a range of jet Re number in laminar, transitional, and turbulent regimes and a range of Weber numbers covering no ullage penetration, partial penetration and complete ullage penetration and break-up (only in microgravity). Numerical prediction of a two-phase CFD model are compared to experimental 1g results to both validate the model and also indicate the effect of the residual non-condensable gas on evolution of pressure and temperature distributions in the tank during pressurization and pressure control.
Şenay, Hasan; Sıvacı, Remziye; Kokulu, Serdar; Koca, Buğra; Bakı, Elif Doğan; Ela, Yüksel
2016-08-01
The aim of this present study is to compare the effect of pressure-controlled ventilation and volume-controlled ventilation on pulmonary mechanics and inflammatory markers in prone position. The study included 41 patients undergoing to vertebrae surgery. The patients were randomized into two groups: Group 1 received volume-controlled ventilation, while group 2 received pressure-controlled ventilation. The demographic data, pulmonary mechanics, the inflammatory marker levels just after the induction of anesthetics, at the 6th and 12th hours, and gas analysis from arterial blood samples taken at the beginning and the 30th minute were recorded. The inflammatory marker levels increased in both groups, without any significant difference among groups. Peak inspiratory pressure level was higher in the volume-controlled ventilation group. This study revealed that there is no difference regarding inflammatory marker levels between volume- and pressure-controlled ventilation.
The Impact of Social Pressure and Monetary Incentive on Cognitive Control
Ličen, Mina; Hartmann, Frank; Repovš, Grega; Slapničar, Sergeja
2016-01-01
We compare the effects of two prominent organizational control mechanisms—social pressure and monetary incentive—on cognitive control. Cognitive control underlies the human ability to regulate thoughts and actions in the pursuit of behavioral goals. Previous studies show that monetary incentives can contribute to goal-oriented behavior by activating proactive control. There is, however, much less evidence of how social pressure affects cognitive control and task performance. In a within-subject experimental design, we tested 47 subjects performing the AX-CPT task to compare the activation of cognitive control modes under social pressure and monetary incentive beyond mere instructions to perform better. Our results indicate that instructing participants to improve their performance on its own leads to a significant shift from a reactive to a proactive control mode and that both social pressure and monetary incentive further enhance performance. PMID:26903901
High pressure common rail injection system modeling and control.
Wang, H P; Zheng, D; Tian, Y
2016-07-01
In this paper modeling and common-rail pressure control of high pressure common rail injection system (HPCRIS) is presented. The proposed mathematical model of high pressure common rail injection system which contains three sub-systems: high pressure pump sub-model, common rail sub-model and injector sub-model is a relative complicated nonlinear system. The mathematical model is validated by the software Matlab and a virtual detailed simulation environment. For the considered HPCRIS, an effective model free controller which is called Extended State Observer - based intelligent Proportional Integral (ESO-based iPI) controller is designed. And this proposed method is composed mainly of the referred ESO observer, and a time delay estimation based iPI controller. Finally, to demonstrate the performances of the proposed controller, the proposed ESO-based iPI controller is compared with a conventional PID controller and ADRC. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Control rod drive hydraulic system
Ose, Richard A.
1992-01-01
A hydraulic system for a control rod drive (CRD) includes a variable output-pressure CR pump operable in a charging mode for providing pressurized fluid at a charging pressure, and in a normal mode for providing the pressurized fluid at a purge pressure, less than the charging pressure. Charging and purge lines are disposed in parallel flow between the CRD pump and the CRD. A hydraulic control unit is disposed in flow communication in the charging line and includes a scram accumulator. An isolation valve is provided in the charging line between the CRD pump and the scram accumulator. A controller is operatively connected to the CRD pump and the isolation valve and is effective for opening the isolation valve and operating the CRD pump in a charging mode for charging the scram accumulator, and closing the isolation valve and operating the CRD pump in a normal mode for providing to the CRD through the purge line the pressurized fluid at a purge pressure lower than the charging pressure.
Numerical Modeling of Cavitating Venturi: A Flow Control Element of Propulsion System
NASA Technical Reports Server (NTRS)
Majumdar, Alok; Saxon, Jeff (Technical Monitor)
2002-01-01
In a propulsion system, the propellant flow and mixture ratio could be controlled either by variable area flow control valves or by passive flow control elements such as cavitating venturies. Cavitating venturies maintain constant propellant flowrate for fixed inlet conditions (pressure and temperature) and wide range of outlet pressures, thereby maintain constant, engine thrust and mixture ratio. The flowrate through the venturi reaches a constant value and becomes independent of outlet pressure when the pressure at throat becomes equal to vapor pressure. In order to develop a numerical model of propulsion system, it is necessary to model cavitating venturies in propellant feed systems. This paper presents a finite volume model of flow network of a cavitating venturi. The venturi was discretized into a number of control volumes and mass, momentum and energy conservation equations in each control volume are simultaneously solved to calculate one-dimensional pressure, density, and flowrate and temperature distribution. The numerical model predicts cavitations at the throat when outlet pressure was gradually reduced. Once cavitation starts, with further reduction of downstream pressure, no change in flowrate is found. The numerical predictions have been compared with test data and empirical equation based on Bernoulli's equation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... level sensing devices that activate an alarm or control the flow, or otherwise prevent discharges. (f) Equip pressure containers with high and low pressure sensing devices that activate an alarm or control... flow conditions, combination of pressure and flow, manual or remote control mechanisms. (k) Install a...
Pressure ramp programmer; IMBLMS Phase B4 Additional Tasks: Task 3.0 pressure ramp programmer
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Reinhardt, C. G.
1972-01-01
A pressure ramp programmer model was designed, fabricated and tested. This model, in conjunction with an automatic blood pressure monitor, automatically controls the pressure in the blood pressure monitor arterial cuff. The cuff pressurization cycle is designed to maximize accuracy and repeatability of blood pressure measurements. The key feature of this automatic cycle is rapid blood pressure cuff bleed down from an initial setting until systolic (diastolic) pressure is encountered followed by a short repressurization and slow bleed, long enough to permit accurate systolic (diastolic) pressure determination. The system includes a pressure reservoir which bleeds the cuff through a precision needle valve; a solenoid valve which permits rapid pressurization from the reservoir; and a pressure sensor which provides information for bleed rate and set point controls. Korotkoff sound signals from a microphone in the blood pressure cuff (not part of the system) provide decision information to the digital control system. The system completed a series of engineering tests using simulated Korotkoff sound inputs. The system performed successfully in all cases and was stable over an extended period of time.
2000-04-12
Investigation S..showed that the pressure reading saturated at 13 bar (maximum limit) compared to 10 bar which the pressure switch should have...controlled to. It was concluded that the commercial grade pressure switch had failed and that the pressure Figure 5: Nitrous Oxide feed system control valve...firing on 11 th April 2000. The performance using a pressure switch to control a solenoid results of this firing are shown in Figure 7. valve giving
A program to evaluate a control system based on feedback of aerodynamic pressure differentials
NASA Technical Reports Server (NTRS)
Levy, D. W.; Finn, P.; Roskam, J.
1981-01-01
The use of aerodynamic pressure differentials to position a control surface is evaluated. The system is a differential pressure command loop, analogous to a position command loop, where the surface is commanded to move until a desired differential pressure across the surface is achieved. This type of control is more direct and accurate because it is the differential pressure which causes the control forces and moments. A frequency response test was performed in a low speed wind tunnel to measure the performance of the system. Both pressure and position feedback were tested. The pressure feedback performed as well as position feedback implying that the actuator, with a break frequency on the order of 10 Rad/sec, was the limiting component. Theoretical considerations indicate that aerodynamic lags will not appear below frequencies of 50 Rad/sec, or higher.
Izumi, So; Okada, Kenji; Hasegawa, Tomomi; Omura, Atsushi; Munakata, Hiroshi; Matsumori, Masamichi; Okita, Yutaka
2010-05-01
Paraplegia from spinal cord ischemia remains an unresolved complication in thoracoabdominal aortic surgery, with high morbidity and mortality. This study investigated postoperative effects of systemic blood pressure augmentation during ischemia. Spinal cord ischemia was induced in rabbits by infrarenal aortic occlusion for 15 minutes with infused phenylephrine (high blood pressure group, n = 8) or nitroprusside (low blood pressure group, n = 8) or without vasoactive agent (control, n = 8). Spinal cord blood flow, transcranial motor evoked potentials, neurologic outcome, and motor neuron cell damage (apoptosis, necrosis, superoxide generation, myeloperoxidase activity) were evaluated. Mean arterial pressures during ischemia were controlled at 121.9 +/- 2.8, 50.8 +/- 4.3, and 82.3 +/- 10.7 mm Hg in high blood pressure, low blood pressure, and control groups, respectively. In high blood pressure group, high spinal cord blood flow (P < .01), fast recovery of transcranial motor evoked potentials (P < .01), and high neurologic score (P < .05) were observed after ischemia relative to low blood pressure and control groups. At 48 hours after ischemia, there were significantly more viable neurons, fewer terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate nick-end labeling-positive neurons, and less alpha-fodrin expression in high blood pressure group than low blood pressure and control groups. Superoxide generation and myeloperoxidase activity at 3 hours after ischemia were suppressed in high blood pressure group relative to low blood pressure group. Augmentation of systemic blood pressure during spinal cord ischemia can reduce ischemic insult and postoperative neurologic adverse events. 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Komori, Yoko; Iwashita, Yukio; Ohta, Masayuki; Kawano, Yuichiro; Inomata, Masafumi; Kitano, Seigo
2014-08-01
A recent study demonstrated that high pressure of carbon dioxide (CO2) pneumoperitoneum before liver resection impairs postoperative liver regeneration. This study was aimed to investigate effects of varying insufflation pressures of CO2 pneumoperitoneum on liver regeneration using a rat model. 180 male Wistar rats were randomly divided into three groups: control group (without preoperative pneumoperitoneum), low-pressure group (with preoperative pneumoperitoneum at 5 mmHg), and high-pressure group (with preoperative pneumoperitoneum at 10 mmHg). After pneumoperitoneum, all rats were subjected to 70% partial hepatic resection and then euthanized at 0 min, 12 h, and on postoperative days (PODs) 1, 2, 4, and 7. Following outcome parameters were used: liver regeneration (liver regeneration rate, mitotic count, Ki-67 labeling index), hepatocellular damage (serum aminotransferases), oxidative stress [serum malondialdehyde (MDA)], interleukin-6 (IL-6), and hepatocyte growth factor (HGF) expression in the liver tissue. No significant differences were observed for all parameters between control and low-pressure groups. The liver regeneration rate and mitotic count were significantly decreased in the high-pressure group than in control and low-pressure groups on PODs 2 and 4. Postoperative hepatocellular damage was significantly greater in the high-pressure group on PODs 1, 2, 4, and 7 compared with control and/or low-pressure groups. Serum MDA levels were significantly higher in the high-pressure group on PODs 1 and 2, and serum IL-6 levels were significantly higher in the high-pressure group at 12 h and on POD 1, compared with control and/or low-pressure groups. The HGF tissue expression was significantly lower in the high-pressure group at 12 h and on PODs 1 and 4, compared with that in control and/or low-pressure groups. High-pressure pneumoperitoneum before 70% liver resection impairs postoperative liver regeneration, but low-pressure pneumoperitoneum has no adverse effects. This study suggests that following laparoscopic liver resection using appropriate pneumoperitoneum pressure, no impairment of liver regeneration occurs.
Ogihara, Toshio; Saruta, Takao; Rakugi, Hiromi; Matsuoka, Hiroaki; Shimamoto, Kazuaki; Shimada, Kazuyuki; Imai, Yutaka; Kikuchi, Kenjiro; Ito, Sadayoshi; Eto, Tanenao; Kimura, Genjiro; Imaizumi, Tsutomu; Takishita, Shuichi; Ueshima, Hirotsugu
2010-08-01
In this prospective, randomized, open-label, blinded end point study, we aimed to establish whether strict blood pressure control (<140 mm Hg) is superior to moderate blood pressure control (> or =140 mm Hg to <150 mm Hg) in reducing cardiovascular mortality and morbidity in elderly patients with isolated systolic hypertension. We divided 3260 patients aged 70 to 84 years with isolated systolic hypertension (sitting blood pressure 160 to 199 mm Hg) into 2 groups, according to strict or moderate blood pressure treatment. A composite of cardiovascular events was evaluated for > or =2 years. The strict control (1545 patients) and moderate control (1534 patients) groups were well matched (mean age: 76.1 years; mean blood pressure: 169.5/81.5 mm Hg). Median follow-up was 3.07 years. At 3 years, blood pressure reached 136.6/74.8 mm Hg and 142.0/76.5 mm Hg, respectively. The blood pressure difference between the 2 groups was 5.4/1.7 mm Hg. The overall rate of the primary composite end point was 10.6 per 1000 patient-years in the strict control group and 12.0 per 1000 patient-years in the moderate control group (hazard ratio: 0.89; [95% CI: 0.60 to 1.34]; P=0.38). In summary, blood pressure targets of <140 mm Hg are safely achievable in relatively healthy patients > or = 70 years of age with isolated systolic hypertension, although our trial was underpowered to definitively determine whether strict control was superior to less stringent blood pressure targets.
Tank Pressure Control Experiment (TPCE)
NASA Technical Reports Server (NTRS)
Bentz, Mike
1992-01-01
The Tank Pressure Control Experiment (TPCE) is a small self-contained STS payload designed to test a jet mixer for cryogenic fluid pressure control. Viewgraphs are presented that describe project organization, experiment objectives and approach, risk management, payload concept and mission plan, and initial test data.
Uncontrolled Hemorrhage Differs From Volume- or Pressure-Matched Controlled Hemorrhage in Swine
2007-10-01
differences between these models, we evaluated the relationship between blood volume loss and blood pressure in controlled versus uncontrolled hemorrhage...aortotomy; (2) group P, controlled hemorrhage matched to the blood pressure profile of group U; or (3) group V, controlled hemorrhage matched to the...hemorrhage and received no fluid resuscitation. Group U resulted in a blood loss of 17.6 T 0.7 mL kgj1 and a reduction in blood pressure to 28 T 3 mmHg at
Demand-type gas supply system for rocket borne thin-window proportional counters
NASA Technical Reports Server (NTRS)
Acton, L. W.; Caravalho, R.; Catura, R. C.; Joki, E. G.
1977-01-01
A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.
Fernando, Malindu E; Crowther, Robert G; Lazzarini, Peter A; Sangla, Kunwarjit S; Wearing, Scott; Buttner, Petra; Golledge, Jonathan
2016-09-15
Current international guidelines advocate achieving at least a 30 % reduction in maximum plantar pressure to reduce the risk of foot ulcers in people with diabetes. However, whether plantar pressures differ in cases with foot ulcers to controls without ulcers is not clear. The aim of this study was to assess if plantar pressures were higher in patients with active plantar diabetic foot ulcers (cases) compared to patients with diabetes without a foot ulcer history (diabetes controls) and people without diabetes or a foot ulcer history (healthy controls). Twenty-one cases with diabetic foot ulcers, 69 diabetes controls and 56 healthy controls were recruited for this case-control study. Plantar pressures at ten sites on both feet and stance phase duration were measured using a pre-established protocol. Primary outcomes were mean peak plantar pressure, pressure-time integral and stance phase duration. Non-parametric analyses were used with Holm's correction to correct for multiple testing. Binary logistic regression models were used to adjust outcomes for age, sex and body mass index. Median differences with 95 % confidence intervals and Cohen's d values (standardised mean difference) were reported for all significant outcomes. The majority of ulcers were located on the plantar surface of the hallux and toes. When adjusted for age, sex and body mass index, the mean peak plantar pressure and pressure-time integral of toes and the mid-foot were significantly higher in cases compared to diabetes and healthy controls (p < 0.05). The stance phase duration was also significantly higher in cases compared to both control groups (p < 0.05). The main limitations of the study were the small number of cases studied and the inability to adjust analyses for multiple factors. This study shows that plantar pressures are higher in cases with active diabetic foot ulcers despite having a longer stance phase duration which would be expected to lower plantar pressure. Whether plantar pressure changes can predict ulcer healing should be the focus of future research. These results highlight the importance of offloading feet during active ulceration in addition to before ulceration.
A Mechanism for Frequency Modulation in Songbirds Shared with Humans
Margoliash, Daniel
2013-01-01
In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways. PMID:23825417
A mechanism for frequency modulation in songbirds shared with humans.
Amador, Ana; Margoliash, Daniel
2013-07-03
In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways.
Evaluation of a Quartz Bourdon Pressure Gage of Wind Tunnel Mach Number Control System Application
NASA Technical Reports Server (NTRS)
Chapin, W. G.
1986-01-01
A theoretical and experimental study was undertaken to determine the feasibility of using the National Transonic Facility's high accuracy Mach number measurement system as part of a closed loop Mach number control system. The theoretical and experimental procedures described are applicable to the engineering design of pressure control systems. The results show that the dynamic response characteristics of the NTF Mach number gage (a Ruska DDR-6000 quartz absolute pressure gage) coupled to a typical length of pressure tubing were only marginally acceptable within a limited range of the facility's total pressure envelope and could not be used in the Mach number control system.
1987-04-01
Pressure Switch Control Circuit . . . . . . ........ 14 13. Pressure Switch Calibration Fixture . . .......... 16...with the pressure switch control oirouit boards. The solenoid oonneoto (SOL) interfaces with the PCD, while the function of the pressure switch (PRESS...signal out 4 Pressure switch (415 VDC) 5 Pressure switch return 6 + 15 VDC CVCC) V 15 VDC (VEE) 8 Instrument ground 9 open 10 Open 11 115 VAC hot (Blk)
Pressure tracking control of vehicle ABS using piezo valve modulator
NASA Astrophysics Data System (ADS)
Jeon, Juncheol; Choi, Seung-Bok
2011-03-01
This paper presents a wheel slip control for the ABS(anti-lock brake system) of a passenger vehicle using a controllable piezo valve modulator. The ABS is designed to optimize for braking effectiveness and good steerability. As a first step, the principal design parameters of the piezo valve and pressure modulator are appropriately determined by considering the braking pressure variation during the ABS operation. The proposed piezo valve consists of a flapper, pneumatic circuit and a piezostack actuator. In order to get wide control range of the pressure, the pressure modulator is desired. The modulator consists of a dual-type cylinder filled with different substances (fluid and gas) and a piston rod moving vertical axis to transmit the force. Subsequently, a quarter car wheel slip model is formulated and integrated with the governing equation of the piezo valve modulator. A sliding mode controller to achieve the desired slip rate is then designed and implemented. Braking control performances such as brake pressure and slip rate are evaluated via computer simulations.
Dervan, Edward; Lee, Edward; Giubilato, Antonio; Khanam, Tina; Maghsoudlou, Panayiotis; Morgan, William H
2017-11-01
This study provides results of a treatment option for patients with failed primary glaucoma drainage device. The study aimed to describe and evaluate the long-term intraocular pressure control and complications of a new technique joining a second glaucoma drainage device directly to an existing glaucoma drainage device termed 'piggyback drainage'. This is a retrospective, interventional cohort study. Eighteen eyes of 17 patients who underwent piggyback drainage between 2004 and 2013 inclusive have been studied. All patients had prior glaucoma drainage device with uncontrolled intraocular pressure. The piggyback technique involved suturing a Baerveldt (250 or 350 mm) or Molteno3 glaucoma drainage device to an unused scleral quadrant and connecting the silicone tube to the primary plate bleb. Failure of intraocular pressure control defined as an intraocular pressure greater than 21 mmHg on maximal therapy on two separate occasions or further intervention to control intraocular pressure. The intraocular pressure was controlled in seven eyes (39%) at last follow-up with a mean follow-up time of 74.2 months. The mean preoperative intraocular pressure was 27.1 mmHg (95% confidence interval 23.8-30.3) compared with 18.4 mmHg (95% confidence interval 13.9-22.8) at last follow-up. The mean time to failure was 57.1 months (95% confidence interval 32.2-82), and the mean time to further surgery was 72.3 months (95% confidence interval 49.9-94.7). Lower preoperative intraocular pressure was associated with longer duration of intraocular pressure control (P = 0.048). If the intraocular pressure was controlled over 2 years, it continued to be controlled over the long term. Two eyes (11%) experienced corneal decompensation. Piggyback drainage represents a viable surgical alternative for the treatment of patients with severe glaucoma with failing primary glaucoma drainage device, particularly in those at high risk of corneal decompensation. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
Increased in-shoe lateral plantar pressures with chronic ankle instability.
Schmidt, Heather; Sauer, Lindsay D; Lee, Sae Yong; Saliba, Susan; Hertel, Jay
2011-11-01
Previous plantar pressure research found increased loads and slower loading response on the lateral aspect of the foot during gait with chronic ankle instability compared to healthy controls. The studies had subjects walking barefoot over a pressure mat and results have not been confirmed with an in-shoe plantar pressure system. Our purpose was to report in-shoe plantar pressure measures for chronic ankle instability subjects compared to healthy controls. Forty-nine subjects volunteered (25 healthy controls, 24 chronic ankle instability) for this case-control study. Subjects jogged continuously on a treadmill at 2.68 m/s (6.0 mph) while three trials of ten consecutive steps were recorded. Peak pressure, time-to-peak pressure, pressure-time integral, maximum force, time-to-maximum force, and force-time integral were assessed in nine regions of the foot with the Pedar-x in-shoe plantar pressure system (Novel, Munich, Germany). Chronic ankle instability subjects demonstrated a slower loading response in the lateral rearfoot indicated by a longer time-to-peak pressure (16.5% +/- 10.1, p = 0.001) and time-to-maximum force (16.8% +/- 11.3, p = 0.001) compared to controls (6.5% +/- 3.7 and 6.6% +/- 5.5, respectively). In the lateral midfoot, ankle instability subjects demonstrated significantly greater maximum force (318.8 N +/- 174.5, p = 0.008) and peak pressure (211.4 kPa +/- 57.7, p = 0.008) compared to controls (191.6 N +/- 74.5 and 161.3 kPa +/- 54.7). Additionally, ankle instability subjects demonstrated significantly higher force-time integral (44.1 N/s +/- 27.3, p = 0.005) and pressure-time integral (35.0 kPa/s +/- 12.0, p = 0.005) compared to controls (23.3 N/s +/- 10.9 and 24.5 kPa/s +/- 9.5). In the lateral forefoot, ankle instability subjects demonstrated significantly greater maximum force (239.9N +/- 81.2, p = 0.004), force-time integral (37.0 N/s +/- 14.9, p = 0.003), and time-to-peak pressure (51.1% +/- 10.9, p = 0.007) compared to controls (170.6 N +/- 49.3, 24.3 N/s +/- 7.2 and 43.8% +/- 4.3). Using an in-shoe plantar pressure system, chronic ankle instability subjects had greater plantar pressures and forces in the lateral foot compared to controls during jogging. These findings may have implications in the etiology and treatment of chronic ankle instability.
A switched energy saving position controller for variable-pressure electro-hydraulic servo systems.
Tivay, Ali; Zareinejad, Mohammad; Rezaei, S Mehdi; Baghestan, Keivan
2014-07-01
The electro-hydraulic servo system (EHSS) demonstrates a relatively low level of efficiency compared to other available actuation methods. The objective of this paper is to increase this efficiency by introducing a variable supply pressure into the system and controlling this pressure during the task of position tracking. For this purpose, an EHSS structure with controllable supply pressure is proposed and its dynamic model is derived from the basic laws of physics. A switching control structure is then proposed to control both the supply pressure and the cylinder position at the same time, in a way that reduces the overall energy consumption of the system. The stability of the proposed switching control system is guaranteed by proof, and its performance is verified by experimental testing. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Stankovicha, Joseph J; Gritti, Fabrice; Beaver, Lois Ann; Stevensona, Paul G; Guiochon, Georges
2013-11-29
Five methods were used to implement fast gradient separations: constant flow rate, constant column-wall temperature, constant inlet pressure at moderate and high pressures (controlled by a pressure controller),and programmed flow constant pressure. For programmed flow constant pressure, the flow rates and gradient compositions are controlled using input into the method instead of the pressure controller. Minor fluctuations in the inlet pressure do not affect the mobile phase flow rate in programmed flow. There producibilities of the retention times, the response factors, and the eluted band width of six successive separations of the same sample (9 components) were measured with different equilibration times between 0 and 15 min. The influence of the length of the equilibration time on these reproducibilities is discussed. The results show that the average column temperature may increase from one separation to the next and that this contributes to fluctuation of the results.
Nilius, Georg; Katamadze, Nato; Domanski, Ulrike; Schroeder, Maik; Franke, Karl-Josef
2017-01-01
COPD patients who develop chronic hypercapnic respiratory failure have a poor prognosis. Treatment of choice, especially the best form of ventilation, is not well known. This study compared the effects of pressure-controlled (spontaneous timed [ST]) non-invasive ventilation (NIV) and NIV with intelligent volume-assured pressure support (IVAPS) in chronic hypercapnic COPD patients regarding the effects on alveolar ventilation, adverse patient/ventilator interactions and sleep quality. This prospective, single-center, crossover study randomized patients to one night of NIV using ST then one night with the IVAPS function activated, or vice versa. Patients were monitored using polysomnography (PSG) and transcutaneous carbon dioxide pressure (PtcCO 2 ) measurement. Patients rated their subjective experience (total score, 0-45; lower scores indicate better acceptability). Fourteen patients were included (4 females, age 59.4±8.9 years). The total number of respiratory events was low, and similar under pressure-controlled (5.4±6.7) and IVAPS (8.3±10.2) conditions ( P =0.064). There were also no clinically relevant differences in PtcCO 2 between pressure-controlled and IVAPS NIV (52.9±6.2 versus 49.1±6.4 mmHg). Respiratory rate was lower under IVAPS overall; between-group differences reached statistical significance during wakefulness and non-rapid eye movement sleep. Ventilation pressures were 2.6 cmH 2 O higher under IVAPS versus pressure-controlled ventilation, resulting in a 20.1 mL increase in breathing volume. Sleep efficiency was slightly higher under pressure-controlled ventilation versus IVAPS. Respiratory arousals were uncommon (24.4/h [pressure-controlled] versus 25.4/h [IVAPS]). Overall patient assessment scores were similar, although there was a trend toward less discomfort during IVAPS. Our results show that IVAPS NIV allows application of higher nocturnal ventilation pressures versus ST without affecting sleep quality or inducing ventilation- associated events.
Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort.
Yoshida, Takeshi; Nakahashi, Susumu; Nakamura, Maria Aparecida Miyuki; Koyama, Yukiko; Roldan, Rollin; Torsani, Vinicius; De Santis, Roberta R; Gomes, Susimeire; Uchiyama, Akinori; Amato, Marcelo B P; Kavanagh, Brian P; Fujino, Yuji
2017-09-01
Spontaneous breathing during mechanical ventilation increases transpulmonary pressure and Vt, and worsens lung injury. Intuitively, controlling Vt and transpulmonary pressure might limit injury caused by added spontaneous effort. To test the hypothesis that, during spontaneous effort in injured lungs, limitation of Vt and transpulmonary pressure by volume-controlled ventilation results in less injurious patterns of inflation. Dynamic computed tomography was used to determine patterns of regional inflation in rabbits with injured lungs during volume-controlled or pressure-controlled ventilation. Transpulmonary pressure was estimated by using esophageal balloon manometry [Pl(es)] with and without spontaneous effort. Local dependent lung stress was estimated as the swing (inspiratory change) in transpulmonary pressure measured by intrapleural manometry in dependent lung and was compared with the swing in Pl(es). Electrical impedance tomography was performed to evaluate the inflation pattern in a larger animal (pig) and in a patient with acute respiratory distress syndrome. Spontaneous breathing in injured lungs increased Pl(es) during pressure-controlled (but not volume-controlled) ventilation, but the pattern of dependent lung inflation was the same in both modes. In volume-controlled ventilation, spontaneous effort caused greater inflation and tidal recruitment of dorsal regions (greater than twofold) compared with during muscle paralysis, despite the same Vt and Pl(es). This was caused by higher local dependent lung stress (measured by intrapleural manometry). In injured lungs, esophageal manometry underestimated local dependent pleural pressure changes during spontaneous effort. Limitation of Vt and Pl(es) by volume-controlled ventilation could not eliminate harm caused by spontaneous breathing unless the level of spontaneous effort was lowered and local dependent lung stress was reduced.
A New Low-frequency Sonophoresis System Combined with Ultrasonic Motor and Transducer
NASA Astrophysics Data System (ADS)
Zhu, Pancheng; Peng, Hanmin; Yang, Jianzhi; Mao, Ting; Sheng, Juan
2018-03-01
Low frequency sonophoresis (LFS) is currently being attempted as a transdermal drug delivery method in clinical areas. However, it lacks both an effective control method and the equipment to satisfy the varying drug dosage requirements of individual patients. Herein, a novel method aimed at controlling permeability is proposed and developed, using a pressure control strategy which is based on an accurate, adjustable and non-invasive ultrasound transdermal drug delivery system in in vitro LFS. The system mainly consists of a lead screw linear ultrasonic motor and an ultrasonic transducer, in which the former offers pressure and the latter provides ultrasound wave in the liquid. The ultrasound can enhance non-invasive permeation and the pressure from the motor can control the permeability. The calculated and experimental results demonstrate that the maximum pressure on artificial skin is under the area with the maximum vibration amplitude of the ultrasonic transducer, and the total pressure consists of acoustic pressure from the transducer and approximate static pressure from the motor. Changing the static pressure from the ultrasonic motor can effectively control the non-invasive permeability, by adjusting the duty ratio or the amplitude of the motor’s driving voltage. In addition, the permeability control of calcein by thrust control is realized in 15 min, indicating the suitability of this method for application in accurate medical technology. The obtained results reveal that the issue of difficult permeability control can be addressed, using this control method in in vitro LFS to open up a route to the design of accurate drug delivery technology for individual patients.
Flight evaluation of an engine static pressure noseprobe in an F-15 airplane
NASA Technical Reports Server (NTRS)
Foote, C. H.; Jaekel, R. F.
1981-01-01
The flight testing of an inlet static pressure probe and instrumented inlet case produced results consistent with sea-level and altitude stand testing. The F-15 flight test verified the basic relationship of total to static pressure ratio versus corrected airflow and automatic distortion downmatch with the engine pressure ratio control mode. Additionally, the backup control inlet case statics demonstrated sufficient accuracy for backup control fuel flow scheduling, and the station 6 manifolded production probe was in agreement with the flight test station 6 tota pressure probes.
Yi, Stella S; Tabaei, Bahman P; Angell, Sonia Y; Rapin, Anne; Buck, Michael D; Pagano, William G; Maselli, Frank J; Simmons, Alvaro; Chamany, Shadi
2015-03-01
Hypertension is a leading risk factor for cardiovascular disease. Although control rates have improved over time, racial/ethnic disparities in hypertension control persist. Self-blood pressure monitoring, by itself, has been shown to be an effective tool in predominantly white populations, but less studied in minority, urban communities. These types of minimally intensive approaches are important to test in all populations, especially those experiencing related health disparities, for broad implementation with limited resources. The New York City Health Department in partnership with community clinic networks implemented a randomized clinical trial (n=900, 450 per arm) to investigate the effectiveness of self-blood pressure monitoring in medically underserved and largely black and Hispanic participants. Intervention participants received a home blood pressure monitor and training on use, whereas control participants received usual care. After 9 months, systolic blood pressure decreased (intervention, 14.7 mm Hg; control, 14.1 mm Hg; P=0.70). Similar results were observed when incorporating longitudinal data and calculating a mean slope over time. Control was achieved in 38.9% of intervention and 39.1% of control participants at the end of follow-up; the time-to-event experience of achieving blood pressure control in the intervention versus control groups were not different from each other (logrank P value =0.91). Self-blood pressure monitoring was not shown to improve control over usual care in this largely minority, urban population. The patient population in this study, which included a high proportion of Hispanics and uninsured persons, is understudied. Results indicate these groups may have additional meaningful barriers to achieving blood pressure control beyond access to the monitor itself. http://clinicaltrials.gov. Unique Identifier: NCT01123577. © 2015 American Heart Association, Inc.
NASA Technical Reports Server (NTRS)
Flachbart, R. H.; Hastings, L. J.; Hedayat, A.; Nelson, S.; Tucker, S.
2006-01-01
In support of the development of a zero gravity pressure control capability for liquid hydrogen, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the effects of helium pressurant on the performance of a spray bar thermodynamic vent system (TVS). Fourteen days of testing was performed in August - September 2005, with an ambient heat leak of about 70-80 watts and tank fill levels of 90%, 50%, and 25%. The TVS successfully controlled the tank pressure within a +/- 3.45 kPa (+/- 0.5 psi) band with various helium concentration levels in the ullage. Relative to pressure control with an "all hydrogen" ullage, the helium presence resulted in 10 to 30 per cent longer pressure reduction durations, depending on the fill level, during the mixing/venting phase of the control cycle. Additionally, the automated control cycle was based on mixing alone for pressure reduction until the pressure versus time slope became positive, at which time the Joule-Thomson vent was opened. Testing was also conducted to evaluate thermodynamic venting without the mixer operating, first with liquid then with vapor at the recirculation line inlet. Although ullage stratification was present, the ullage pressure was successfully controlled without the mixer operating. Thus, if vapor surrounded the pump inlet in a reduced gravity situation, the ullage pressure can still be controlled by venting through the TVS Joule Thomson valve and heat exchanger. It was evident that the spray bar configuration, which extends almost the entire length of the tank, enabled significant thermal energy removal from the ullage even without the mixer operating. Details regarding the test setup and procedures are presented in the paper. 1
The effect of adjunctive noncontact low frequency ultrasound on deep tissue pressure injury.
Honaker, Jeremy S; Forston, Michael R; Davis, Emily A; Weisner, Michelle M; Morgan, Jennifer A; Sacca, Emily
2016-11-01
The optimal treatment for deep tissue pressure injuries has not been determined. Deep tissue pressure injuries represent a more ominous early stage pressure injury that may evolve into full thickness ulceration despite implementing the standard of care for pressure injury. A longitudinal prospective historical case control study design was used to determine the effectiveness of noncontact low frequency ultrasound plus standard of care (treatment group) in comparison to standard of care (control group) in reducing deep tissue pressure injury severity, total surface area, and final pressure injury stage. The Honaker Suspected Deep Tissue Injury Severity Scale (range 3-18[more severe]) was used to determine deep tissue pressure injury severity at enrollment (Time 1) and discharge (Time 2). A total of 60 subjects (Treatment = 30; Control= 30) were enrolled in the study. In comparison to the control group mean deep tissue pressure injury total surface area change at Time 2 (0.3 cm 2 ), the treatment group had a greater decrease (8.8 cm 2 ) that was significant (t = 2.41, p = 0.014, r 2 = 0.10). In regards to the Honaker Suspected Deep Tissue Injury Severity Scale scores, the treatment group had a significantly lower score (7.6) in comparison to the control group (11.9) at time 2, with a mean difference of 4.6 (t = 6.146, p = 0.0001, r 2 = 0.39). When considering the final pressure ulcer stage at Time 2, the control group were mostly composed of unstageable pressure ulcer (57%) and deep tissue pressure injury severity (27%). In contrast, the treatment group final pressure ulcer stages were less severe and were mostly composed of stage 2 pressure injury (50%) and deep tissue pressure injury severity (23%) were the most common at time 2. The results of this study have shown that deep tissue pressure injury severity treated with noncontact low frequency ultrasound within 5 days of onset and in conjunction with standard of care may improve outcomes as compared to standard of care only. © 2016 by the Wound Healing Society.
Billhult, A; Lindholm, C; Gunnarsson, Ronny; Stener-Victorin, E
2009-10-05
To examine the short-term effects of light pressure effleurage on circulating lymphocytes by studying the number and activity of peripheral blood natural killer (NK) cells in patients with breast cancer compared to a control group. Furthermore, the effect of light pressure effleurage on salivary cortisol levels, heart rate and blood pressure was studied. Single centre, prospective, randomized and controlled study. Thirty women, aged 50 to 75 years (mean 61 sd=7.2) with breast cancer undergoing radiation therapy in a hospital in southwestern Sweden were enrolled in the study. They were allocated to either receive massage in the form of a full-body light pressure effleurage treatment, or a control visit where they were given an equal amount of attention. Blood samples, saliva, notation of heart rate and blood pressure were collected before and after massage/control visit. Differences in change over time between groups were analyzed by Student's t-test. Light pressure effleurage massage decreased the deterioration of NK cell activity occurring during radiation therapy. Furthermore it lowered heart rate and systolic blood pressure. No effects were demonstrated on cortisol and diastolic pressure. A single full-body light pressure effleurage massage has a short-term effect on NK cell activity, systolic blood pressure and heart rate in patients with breast cancer. However, the long-term clinical importance of these findings needs to be further investigated.
Surface controlled blade stabilizer
Russell, Larry R.
1983-01-01
Drill string stabilizer apparatus, controllable to expand and retract entirely from the surface by control of drill string pressure, wherein increase of drill string pressure from the surface closes a valve to create a piston means which is moved down by drill string pressure to expand the stabilizer blades, said valve being opened and the piston moving upward upon reduction of drill string pressure to retract the stabilizer blades. Upward and downward movements of the piston and an actuator sleeve therebelow are controlled by a barrel cam acting between the housing and the actuator sleeve.
Pressure compensated flow control valve
Minteer, Daniel J.
1999-01-01
The invention is an air flow control valve which is capable of maintaining a constant flow at the outlet despite changes in the inlet or outlet pressure. The device consists of a shell assembly with an inlet chamber and outlet chamber separated by a separation plate. The chambers are connected by an orifice. Also located within the inlet chamber is a port controller assembly. The port controller assembly consists of a differential pressure plate and port cap affixed thereon. The cap is able to slide in and out of the orifice separating the inlet and outlet chambers. When the pressure differential is sufficient, the differential pressure plate rises or falls to maintain a constant air flow. Movement of the port controller assembly does not require the use of seals, diaphragms, tight tolerances, bushings, bearings, hinges, guides, or lubricants.
Fici, F; Seravalle, G; Koylan, N; Nalbantgil, I; Cagla, N; Korkut, Y; Quarti-Trevano, F; Makel, W; Grassi, G
2017-09-01
Although improved during the past few years, blood pressure control remains sub optimal. The impact of follow-up assessment on blood pressure control was evaluated in a group of patients of the HYT (HYperTension survey), treated with a combination of different dihydropyridine calcium-channel blockers (CCBs regimen) and inhibitors of renin-angiotensin-aldosterone system (RAAS) and with uncontrolled blood pressure. This was obtained assessing (a) the rate of blood pressure control at 3 and 6 months of follow-up in the whole group of patients, (b) the rate of blood pressure control and the average blood pressure values in subjects treated with different DHP-CCBs regimen. From the 4993 patients with uncontrolled blood pressure, (BP ≥ 140/90 or ≥140/85 in patients with diabetes), 3729 (mean age 61.2 ± 11.5 years), maintained CCBs regimen combined wih RAAS blockers and were evaluated at 3 and 6 months follow-up. At each visit BP (semiautomatic device, Omron-M6, 3 measurements), heart rate, adverse events and treatment persistence were collected. At 1st and 2nd follow-up the rate of controlled BP was 63.5 and 72.8% respectively (p < 0.05 vs 35.3% at baseline), whereas in diabetes was 32.5 and 37.9% respectively (p < 0.05 vs 20% at baseline). No differences in heart rate were observed. No differences in control rate were observed between the different CCBs regimen. The incidence of drugs related adverse events was 3.6%. These findings provide evidence that: (a) the follow-up of hypertensive patients under therapy increase the rate of blood pressure control; (b) there is no significant difference in the antihypertensive effect between different CCBs regimen; (c) lipophilic CCBs induce less ankle edema.
Hammer, Lawrence D.; Huffman, Lynne C.; Mascola, Anthony; Bryson, Susan W.; Danaher, Carol
2012-01-01
Objective To ascertain whether a parent education program based on Satter’s division of responsibility in feeding children (DOR) is effective in enhancing parent/child feeding interactions for children with an overweight/obese parent. The primary hypothesis was that the intervention would decrease parental pressure to eat. Methods Sixty-two families with a child aged 2–4 years with at least one overweight/obese parent were randomly allocated using a cluster design to either the DOR intervention or a control group. The control group focused on increasing family consumption of healthy foods and activity levels, and enhancing child sleep duration. The primary outcome was parent pressure on their child to eat. Results The DOR intervention was superior to the control group in reducing pressure to eat. Two moderators of pressure to eat were found: disinhibition of eating and hunger. DOR group parents irrespective of disinhibition levels lowered pressure to eat whereas control group parents with low disinhibition increased pressure to eat. There were similar findings for hunger. Gender moderated restrictive feeding with DOR parents lowering restriction more than the control group in girls only. Conclusion The DOR intervention was more effective in reducing parent pressure to eat and food restriction (in girls only) than the control group. PMID:22947882
[Analysis of the characteristic of pharyngeal paraesthesia patients by high resolution manometry].
Gu, Yun; Qian, Wei
2015-09-01
To discuss the pressure changing characteristics of upper esophageal sphincter (UES), lower esophageal sphincter (LES) and the esophagus kinetic characteristics of pharyngeal paraesthesia patients. To take high resolution manometry in 44 cases of pharyngeal paraesthesia patients and 23 normal subjects separately. According to the RSI score,the 44 patients were divided into group A (the group without reflux, RSI < 13, n = 25) and group B (the group with reflux, RSI ≥ 13, n = 19). The UES average resting pressure and average residual pressure of patients group were higher than the control group (P < 0.05); The UES average resting pressure and average residual pressure of group B were higher than group A (P < 0.05); The LES average resting pressure and average residual pressure of group B were lower than group A and the control group (P < 0.05); The comparison of LES average resting pressure and average residual pressure between group A and the control group was not statistically significant (P > 0.05). The esophagus DCI of group B was lower than that of group A and control group (P < 0.05). The esophagus DCI comparison between group A and control group was not statistically significant (P > 0.05). The pharyngeal paresthesia symptoms of'patients was associated with the increasing of UES pressure. The pharyngeal paresthesia symptoms of group with reflux was related to low pressure of LES and high pressure of UES. The last part of esophagus of group with reflux had obstacles in powers, which weaken the peristalsis and declined the ability to clear the bolus and gastric reflux material.
Mori, Takefumi; Cowley, Allen W
2004-04-01
Renal perfusion pressure was servo-controlled chronically in rats to quantify the relative contribution of elevated arterial pressure versus angiotensin II (Ang II) on the induction of renal injury in Ang II-induced hypertension. Sprague-Dawley rats fed a 4% salt diet were administered Ang II for 14 days (25 ng/kg per minute IV; saline only for sham rats), and the renal perfusion pressure to the left kidney was continuously servo-controlled to maintain a normal pressure in that kidney throughout the period of hypertension. An aortic occluder was implanted around the aorta between the two renal arteries and carotid and femoral arterial pressure were measured continuously throughout the experiment to determine uncontrolled and controlled renal perfusion pressure, respectively. Renal perfusion pressure of uncontrolled, controlled, and sham kidneys over the period of Ang II or saline infusion averaged 152.6+/-7.0, 117.4+/-3.5, and 110.7+/-2.2 mm Hg, respectively. The high-pressure uncontrolled kidneys exhibited tubular necrosis and interstitial fibrosis, especially prominent in the outer medullary region. Regional glomerular sclerosis and interlobular artery injury were also pronounced. Controlled kidneys were significantly protected from interlobular artery injury, juxtamedullary glomeruli injury, tubular necrosis, and interstitial fibrosis as determined by comparing the level of injury. Glomerular injury was not prevented in the outer cortex. Transforming growth factor (TGF)-beta and active NF-kappaB proteins determined by immunohistochemistry were colocalized in the uncontrolled kidney in regions of interstitial fibrosis. We conclude that the preferential juxtamedullary injury found in Ang II hypertension is largely induced by pressure and is probably mediated through the TGF-beta and NF-kappaB pathway.
Automated control of endotracheal tube cuff pressure during simulated flight.
Blakeman, Thomas; Rodriquez, Dario; Woods, James; Cox, Daniel; Elterman, Joel; Branson, Richard
2016-11-01
Successful mechanical ventilation requires that the airway be controlled by an endotracheal tube (ETT) with an inflatable cuff to seal the airway. Aeromedical evacuation represents a unique challenge in which to manage ETT cuffs. We evaluated three methods of automatic ETT cuff pressure adjustment during changes in altitude in an altitude chamber. Size 7.5 and 8.0 mm ETTs that are currently included in the Critical Care Air Transport Team allowance standard were used for the evaluation. Three automatic cuff pressure controllers-Intellicuff, Hamilton Medical; Pyton, ARM Medical; and Cuff Sentry, Outcome Solutions-were used to manage cuff pressures. The fourth group had cuff pressure set at sea level without further adjustment. Each ETT was inserted into a tracheal model and taken to 8,000 feet and then to 16,000 feet at 2,500 ft/min. Baseline cuff pressure at sea level was approximately 25 cm H2O. Mean cuff pressure at both altitudes with both size ETTs was as follows: Control arm, 141 ± 64 cm H2O; Pyton, 25 ± 0.8 cm H2O; Cuff Sentry, 22 ± 0.3 cm H2O; and Intellicuff, 29 ± 6.6 cm H2O. The mean time that cuff pressure was >30 cm H2O using Intellicuff at both altitudes was 2.8 ± 0.8 minutes. Pressure differences from baseline in the control arm and with Intellicuff were statistically significant. Cuff pressure with the Cuff Sentry tended to be lower than indicated on the device. Mean cuff pressures were within the recommended range with all three devices. Intellicuff had difficulty regulating the cuff pressure initially with increases in altitude but was able to reduce the pressure to a safe level during the stabilization period at each altitude. The Pyton and Cuff Sentry allowed the least variation in pressure throughout the evaluation, although the Cuff Sentry set pressure was less than the actual pressure. Therapeutic study, level V.
Cryogenic Pressure Control Modeling for Ellipsoidal Space Tanks in Reduced Gravity
NASA Technical Reports Server (NTRS)
Hedayat, Ali; Lopez, Alfredo; Grayson, Gary D.; Chandler, Frank O.; Hastings, Leon J.
2008-01-01
A computational fluid dynamics (CFD) model is developed to simulate pressure control of an ellipsoidal-shaped liquid hydrogen tank under external heating in low gravity. Pressure control is provided by an axial jet thermodynamic vent system (TVS) centered within the vessel that injects cooler liquid into the tank, mixing the contents and reducing tank pressure. The two-phase cryogenic tank model considers liquid hydrogen in its own vapor with liquid density varying with temperature only and a fully compressible ullage. The axisymmetric model is developed using a custom version of the commercially available FLOW-3D software and simulates low gravity extrapolations of engineering checkout tests performed at Marshall Space Flight Center in 1999 in support of the Solar Thermal Upper Stage Technology Demonstrator (STUSTD) program. Model results illustrate that stable low gravity liquid-gas interfaces are maintained during all phases of the pressure control cycle. Steady and relatively smooth ullage pressurization rates are predicted. This work advances current low gravity CFD modeling capabilities for cryogenic pressure control and aids the development of a low cost CFD-based design process for space hardware.
Pressure regulates osteoclast formation and MCSF expression in marrow culture.
Rubin, J; Biskobing, D; Fan, X; Rubin, C; McLeod, K; Taylor, W R
1997-01-01
One of the forces generated during skeletal loading is hydrostatic pressure. In the work presented here, the ability of increased pressure to influence recruitment of osteoclasts was evaluated. Murine marrow cultures, with pO2 and pCO2 kept constant, were subjected to either control (1.0 atm) or elevated (1.37 or 2.0 atm) hydrostatic pressure. As compared to control, cultures pressurized for 6 days at 1.37 atm formed less osteoclast-like cells (OCLC) (71 +/- 6% of control, P < 0.0001). A similar degree of inhibition occurred in cultures exposed to pressure during days 2-4 only (62 +/- 6%), while treatment during days 5-7 failed to inhibit the OCLC number relative to control (99 +/- 5%). Delivery of 2.0 atm pressure on days 2-4 generated 52 +/- 4% OCLC compared to control. Since macrophage colony stimulating factor (MCSF)-dependent proliferation of osteoclast precursors occurs during the pressure-sensitive period, semiquantitative RT-PCR for MCSF mRNA was performed after 3 days in 1.37 atm (days 2-4). As compared to controls, pressure caused a decrease in mRNA coding for the membrane bound form of MCSF (71.2 +/- 4% (n = 25, P < or = 0.05), while the MCSF RT-PCR product representing the secreted form showed no consistent change. This lack of response of the soluble MCSF RT-PCR product was expected, as levels of bioassayable MCSF were not altered by pressure. Extrapolating these data to in vivo conditions suggests that load-bearing will inhibit the formation of osteoclasts.
Hybrid Feedforward-Feedback Noise Control Using Virtual Sensors
NASA Technical Reports Server (NTRS)
Bean, Jacob; Fuller, Chris; Schiller, Noah
2016-01-01
Several approaches to active noise control using virtual sensors are evaluated for eventual use in an active headrest. Specifically, adaptive feedforward, feedback, and hybrid control structures are compared. Each controller incorporates the traditional filtered-x least mean squares algorithm. The feedback controller is arranged in an internal model configuration to draw comparisons with standard feedforward control theory results. Simulation and experimental results are presented that illustrate each controllers ability to minimize the pressure at both physical and virtual microphone locations. The remote microphone technique is used to obtain pressure estimates at the virtual locations. It is shown that a hybrid controller offers performance benefits over the traditional feedforward and feedback controllers. Stability issues associated with feedback and hybrid controllers are also addressed. Experimental results show that 15-20 dB reduction in broadband disturbances can be achieved by minimizing the measured pressure, whereas 10-15 dB reduction is obtained when minimizing the estimated pressure at a virtual location.
Differential Pressure Switch after the Missile is erected in the tower and connected to Launch Control Circuitry. In addition, a procedure for the ’end to end’ of the L02 and Fuel Tank Pressure Meters is provided. (Author)
Chapellier, R.A.; Rogers, I.
1961-06-27
Accurate and controlled drive for the control rod is from an electric motor. A hydraulic arrangement is provided to balance a piston against which a control rod is urged by the application of fluid pressure. The electric motor drive of the control rod for normal operation is made through the aforementioned piston. In the event scramming is required, the fluid pressure urging the control rod against the piston is relieved and an opposite fluid pressure is applied. The lack of mechanical connection between the electric motor and control rod facilitates the scramming operation.
[Hypertension in Mexican adults: prevalence, diagnosis and type of treatment. Ensanut MC 2016.
Campos-Nonato, Ismael; Hernández-Barrera, Lucía; Pedroza-Tobías, Andrea; Medina, Catalina; Barquera, Simón
2018-01-01
To describe the prevalence, awareness and proportion of adults with an adequate control of hypertension. Blood pressure was measured at 8 352 adults who participated in the Ensanut MC 2016. The adults who reported having diagnosis of hypertension or had systolic blood pressure values (TAS) ≥140mmHg or diastolic blood pressure (TAD) ≥90mmHg were classified as hypertensive. Hypertension was considered controlled when blood pressure was TAS <140mmHg and TAD <90mmHg. The prevalence of hypertension was 25.5%. Of these, 40.0% were unaware of having high blood pressure. Of the hypertensive adults who had previous diagnosis of hypertension and receiving drug treatment (79.3%), 45.6% had blood pressure under control. A high percentage of adults are unaware of having hypertension and nearly half have inadequate control. The relevance of current programmes for diagnosing hypertension should be assessed, as well as the effectiveness of their control strategies.
Managing Stress to Control High Blood Pressure
... Venous Thromboembolism Aortic Aneurysm More Managing Stress to Control High Blood Pressure Updated:Jan 29,2018 The ... limits. Reduce stress by recognizing where you have control You can’t control all the outside events ...
Balijepalli, Chakrapani; Bramlage, Peter; Lösch, Christian; Zemmrich, Claudia; Humphries, Karin H; Moebus, Susanne
2014-06-01
Contemporary epidemiological data on blood pressure readings, hypertension prevalence and control in unselected patient populations covering a broad age range are scarce. The aim here is to report the prevalence of high blood pressure and to identify factors associated with blood pressure control in a large German primary care sample. We used data from the German Metabolic and Cardiovascular Risk Study including 35 869 patients aged 18-99 years. High blood pressure was defined as systolic blood pressure ≥140 mm Hg and/or diastolic blood pressure ≥90 mm Hg or using antihypertensive therapy. Factors associated with blood pressure control among patients receiving antihypertensive therapy were examined using multiple logistic regressions to estimate odds ratios and 95% confidence intervals. The prevalence of high blood pressure, uncontrolled high blood pressure and untreated high blood pressure was 54.8%, 21.3% and 17.6%, respectively. Age >50 years (1.52; 1.40-1.65), male sex (1.30; 1.20-1.41), elevated waist circumference (1.55; 1.45-1.65), high cholesterol (1.24; 1.16-1.33), high triglycerides (1.11; 1.04-1.19) and concomitant diabetes (1.29; 1.20-1.40) were independently associated with uncontrolled high blood pressure. In a majority of patients we observed hypertension despite treatment for high blood pressures. Studies examining the reasons for treatment failure are highly warranted.
Water loss control using pressure management: life-cycle energy and air emission effects.
Stokes, Jennifer R; Horvath, Arpad; Sturm, Reinhard
2013-10-01
Pressure management is one cost-effective and efficient strategy for controlling water distribution losses. This paper evaluates the life-cycle energy use and emissions for pressure management zones in Philadelphia, Pennsylvania, and Halifax, Nova Scotia. It compares water savings using fixed-outlet and flow-modulated pressure control to performance without pressure control, considering the embedded electricity and chemical consumption in the lost water, manufacture of pipe and fittings to repair breaks caused by excess pressure, and pressure management. The resulting energy and emissions savings are significant. The Philadelphia and Halifax utilities both avoid approximately 130 million liters in water losses annually using flow-modulated pressure management. The conserved energy was 780 GJ and 1900 GJ while avoided greenhouse gas emissions were 50 Mg and 170 Mg a year by Philadelphia and Halifax, respectively. The life-cycle financial and environmental performance of pressure management systems compares favorably to the traditional demand management strategy of installing low-flow toilets. The energy savings may also translate to cost-effective greenhouse gas emission reductions depending on the energy mix used, an important advantage in areas where water and energy are constrained and/or expensive and greenhouse gas emissions are regulated as in California, for example.
Optimal control of CPR procedure using hemodynamic circulation model
Lenhart, Suzanne M.; Protopopescu, Vladimir A.; Jung, Eunok
2007-12-25
A method for determining a chest pressure profile for cardiopulmonary resuscitation (CPR) includes the steps of representing a hemodynamic circulation model based on a plurality of difference equations for a patient, applying an optimal control (OC) algorithm to the circulation model, and determining a chest pressure profile. The chest pressure profile defines a timing pattern of externally applied pressure to a chest of the patient to maximize blood flow through the patient. A CPR device includes a chest compressor, a controller communicably connected to the chest compressor, and a computer communicably connected to the controller. The computer determines the chest pressure profile by applying an OC algorithm to a hemodynamic circulation model based on the plurality of difference equations.
TankSIM: A Cryogenic Tank Performance Prediction Program
NASA Technical Reports Server (NTRS)
Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Moder, J. P.; Schnell, A. R.; Sutherlin, S. G.
2015-01-01
Accurate prediction of the thermodynamic state of the cryogenic propellants in launch vehicle tanks is necessary for mission planning and successful execution. Cryogenic propellant storage and transfer in space environments requires that tank pressure be controlled. The pressure rise rate is determined by the complex interaction of external heat leak, fluid temperature stratification, and interfacial heat and mass transfer. If the required storage duration of a space mission is longer than the period in which the tank pressure reaches its allowable maximum, an appropriate pressure control method must be applied. Therefore, predictions of the pressurization rate and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning of future space exploration missions. This paper describes an analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. It is written in the FORTRAN 90 language and can be compiled with any Visual FORTRAN compiler. A thermodynamic vent system (TVS) is used to achieve tank pressure control. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, and mixing. Details of the TankSIM program and comparisons of its predictions with test data for liquid hydrogen and liquid methane will be presented in the final paper.
Chiari, Paolo; Giorgi, Sabina; Ugolini, Daniela; Montanari, Morena; Giudanella, Pietro; Gramantieri, Antonella; Collesi, Franca; Pau, Michelina; Smaldone, Maddalena; Matarasso, Maddalena; Mazzini, Cinzia; Russo, Francesca; Gazineo, Domenica; Fontana, Mirella; Taddia, Patrizia
2012-01-01
Randomized controlled trial on the effectiveness of Corpitolinol 60 in the prevention of pressure sores in surgical patients. The risk of pressure sores in surgical patients is widely recognised. The Corpitolinol 60 (Sanyréne®) applied on compressed areas seems to reduce the risk of pressure sores. To assess the efficacy of Corpitolinol 60 in preventing pressure sores in the operatory theatre. The open label randomized clinical trial was conducted in 5 operating theatres of Northen Italy. Patients were randomized to receive Corpitolinol 60 in areas undergoing compression. Experimental group and controls were treated with usual measures for preventing pressure sores. The lesions were staged according to NPUAP up to 24 hours after surgery. Three-hundred-one patients were randomized (155 in the Sanyréne® group and 143 controls). The main variables predictive of pressure sores risk (ASA class, sex, age, duration of the surgery, and BMI) were comparable across groups. At the end of the surgery 71 patients (23.8%) in the experimental group and 47 controls (30.8%) had a pressure sore (p 0.006; RR 1.81 IC95% 1.17-2.79). Twelve and 24 hours after surgery the differences between groups were not significant. The aim of reducing pressure sores was not reached for patients treated with Corpitolinol 60.
Laboratory Simulation and Measurement of Instrument Drift in Quartz-Resonant Pressure Gauges
NASA Astrophysics Data System (ADS)
Sasagawa, G. S.; Zumberge, M. A.
2017-12-01
Marine geodesy uses ocean bottom pressure sensors to measure vertical deformation of the sea floor, including that due to volcanic inflation and subsidence, episodic tremor and slip, plate subduction, and deformation due to hydrocarbon extraction at offshore reservoirs. Instrumental drift is inherent in existing pressure sensors and introduce uncertainties in data interpretation. Different methods have been developed to control drift, using varying techniques and instrumentation. Laboratory measurements of sensor drift, under controlled conditions that simulate seafloor pressures and temperatures, would allow for evaluating pressure gauge drift and the efficacy of new drift control methods. We have constructed and operated a laboratory system to monitor the drift of 15 quartz resonant pressure gauges over a year. The temperature and pressure are maintained and controlled at approximately 5 °C and 1900 dbar. A deadweight tester was used to provide a reference signal at frequent intervals; the time series of reference pressure signals is a direct measure of each gauge's drift. Several other tests were conducted, including a) evaluation of a custom outgassing sensor used as proxy for instrument drift, b) determination of the oscillator drift in the pressure gauge signal conditioning electronics, and c) a test of ambient air pressure calibration, also known as the A-0-A method. First results will be presented.
Halawa, Mohammed R; Eid, Yara M; El-Hilaly, Rana A; Abdelsalam, Mona M; Amer, Amr H
Foot disease is a common complication of type 2 diabetes that can have tragic consequences. Abnormal plantar pressures are considered to play a major role in the pathologies of neuropathic ulcers in the diabetic foot. To examine Relationship of Planter Pressure and Glycemic Control in Type 2 Diabetic Patients with and without Neuropathy. The study was conducted on 50 type 2 diabetic patients and 30 healthy volunteers. BMI calculation, disease duration, Hemoglobin A1c and presence of neuropathy (by history, foot examination and DN4 questionnaire) were recorded. Plantar pressure was recorded for all patients using the Mat-scan (Tekscan, Inc.vers. 6.34 Boston USA) in static conditions (standing) and dynamic conditions (taking a step on the Mat-scan). Plantar pressures (kPa) were determined at the five metatarsal areas, mid foot area, medial and lateral heel areas and medial three toes. Static and dynamic plantar pressures in both right and left feet were significantly higher in diabetic with neuropathy group than in control group in measured areas (P<0.05). Static and dynamic pressures in right and left feet were significantly higher in diabetic with neuropathy group than in diabetic without neuropathy group in measured areas (P<0.05). On comparison between controls and diabetic without neuropathy group there was a significant difference in plantar pressures especially in metatarsal areas (P<0.05). No significant correlations were present between the studied variables age, disease duration, BMI and HbA1c and plantar pressures in all studied areas. Persons with diabetic neuropathy have elevated peak plantar pressure (PPP) compared to patients without neuropathy and control group. HbA1c% as a surrogate for glycemic control had no direct impact on peak planter pressure, yet it indirectly impacts neuropathy evolution through out disease duration eventually leading to the drastic planter pressure and gait biomechanics changes. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Interactive simulation system for artificial ventilation on the internet: virtual ventilator.
Takeuchi, Akihiro; Abe, Tadashi; Hirose, Minoru; Kamioka, Koichi; Hamada, Atsushi; Ikeda, Noriaki
2004-12-01
To develop an interactive simulation system "virtual ventilator" that demonstrates the dynamics of pressure and flow in the respiratory system under the combination of spontaneous breathing, ventilation modes, and ventilator options. The simulation system was designed to be used by unexperienced health care professionals as a self-training tool. The system consists of a simulation controller and three modules: respiratory, spontaneous breath, and ventilator. The respiratory module models the respiratory system by three resistances representing the main airway, the right and left lungs, and two compliances also representing the right and left lungs. The spontaneous breath module generates inspiratory negative pressure produced by a patient. The ventilator module generates driving force of pressure or flow according to the combination of the ventilation mode and options. These forces are given to the respiratory module through the simulation controller. The simulation system was developed using HTML, VBScript (3000 lines, 100 kB) and ActiveX control (120 kB), and runs on Internet Explorer (5.5 or higher). The spontaneous breath is defined by a frequency, amplitude and inspiratory patterns in the spontaneous breath module. The user can construct a ventilation mode by setting a control variable, phase variables (trigger, limit, and cycle), and options. Available ventilation modes are: controlled mechanical ventilation (CMV), continuous positive airway pressure, synchronized intermittent mandatory ventilation (SIMV), pressure support ventilation (PSV), SIMV + PSV, pressure-controlled ventilation (PCV), pressure-regulated volume control (PRVC), proportional assisted ventilation, mandatory minute ventilation (MMV), bilevel positive airway pressure (BiPAP). The simulation system demonstrates in a graph and animation the airway pressure, flow, and volume of the respiratory system during mechanical ventilation both with and without spontaneous breathing. We developed a web application that demonstrated the respiratory mechanics and the basic theory of ventilation mode.
Orozco-Beltrán, Domingo; Brotons, Carlos; Moral, Irene; Soriano, Nuria; Del Valle, María A; Rodríguez, Ana I; Pepió, Josep M; Pastor, Ana
2008-03-01
The aim of this observational study was to identify factors influencing the control of blood pressure (i.e., <140/90 mmHg, or <130/80 mmHg in diabetic patients) and low-density lipoprotein (LDL) cholesterol level (<100 mg/dL) in 1223 patients with cardiovascular disease. Overall, 70.2% of patients were men, and their mean age was 66.4 years. Blood pressure was poorly controlled in 50.9% (95% confidence interval [CI], 46.9%-54.8%) and the LDL cholesterol level was poorly controlled in 60.1% (95% CI, 56.3%-63.9%). Determinants of poor blood pressure control were diabetes, hypertension, no previous diagnosis of heart failure, previous diagnosis of peripheral artery disease or stroke, obesity, and no lipid-lowering treatment. Determinants of poor LDL cholesterol control were no lipid-lowering treatment, no previous diagnosis of ischemic heart disease, no antihypertensive treatment, and dyslipidemia. The factors affecting blood pressure control were different from those affecting LDL cholesterol control, an observation that should be taken into account when implementing treatment recommendations for achieving therapeutic objectives in secondary prevention.
HealthLines: Control Blood Pressure, Protect Your Kidneys
... Home Current Issue Past Issues Health Lines Control Blood Pressure, Protect Your Kidneys Past Issues / Fall 2008 Table ... on. By Shana Potash, Staff Writer, NLM High blood pressure is a leading cause of chronic kidney disease ( ...
Controlling your high blood pressure
Controlling hypertension ... when you wake up. For people with very high blood pressure, this is when they are most at risk ... 2014 evidence-based guideline for the management of high blood pressure in adults: report from the panel members appointed ...
NASA Technical Reports Server (NTRS)
Green, Del L.; Walker, Eric L.; Everhart, Joel L.
2006-01-01
Minimization of uncertainty is essential to extend the usable range of the 15-psid Electronically Scanned Pressure [ESP) transducer measurements to the low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources inducing much of this uncertainty requires a well defined and controlled calibration method. Employing such a controlled calibration system, several studies were conducted that provide quantitative information detailing the required controls needed to minimize environmental and human induced error sources. Results of temperature, environmental pressure, over-pressurization, and set point randomization studies for the 15-psid transducers are presented along with a comparison of two regression methods using data acquired with both 0.36-psid and 15-psid transducers. Together these results provide insight into procedural and environmental controls required for long term high-accuracy pressure measurements near 0.01 psia in the hypersonic testing environment using 15-psid ESP transducers.
NASA Technical Reports Server (NTRS)
Green, Del L.; Walker, Eric L.; Everhart, Joel L.
2006-01-01
Minimization of uncertainty is essential to extend the usable range of the 15-psid Electronically Scanned Pressure (ESP) transducer measurements to the low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources inducing much of this uncertainty requires a well defined and controlled calibration method. Employing such a controlled calibration system, several studies were conducted that provide quantitative information detailing the required controls needed to minimize environmental and human induced error sources. Results of temperature, environmental pressure, over-pressurization, and set point randomization studies for the 15-psid transducers are presented along with a comparison of two regression methods using data acquired with both 0.36-psid and 15-psid transducers. Together these results provide insight into procedural and environmental controls required for long term high-accuracy pressure measurements near 0.01 psia in the hypersonic testing environment using 15-psid ESP transducers.
NASA Astrophysics Data System (ADS)
Deem, Eric; Cattafesta, Louis; Zhang, Hao; Rowley, Clancy
2016-11-01
Closed-loop control of flow separation requires the spatio-temporal states of the flow to be fed back through the controller in real time. Previously, static and dynamic estimation methods have been employed that provide reduced-order model estimates of the POD-coefficients of the flow velocity using surface pressure measurements. However, this requires a "learning" dataset a priori. This approach is effective as long as the dynamics during control do not stray from the learning dataset. Since only a few dynamical features are required for feedback control of flow separation, many of the details provided by full-field snapshots are superfluous. This motivates a state-observation technique that extracts key dynamical features directly from surface pressure, without requiring PIV snapshots. The results of identifying DMD modes of separated flow through an array of surface pressure sensors in real-time are presented. This is accomplished by employing streaming DMD "on the fly" to surface pressure snapshots. These modal characteristics exhibit striking similarities to those extracted from PIV data and the pressure field obtained via solving Poisson's equation. Progress towards closed-loop separation control based on the dynamic modes of surface pressure will be discussed. Supported by AFOSR Grant FA9550-14-1-0289.
Development and Characterization of a Low-Pressure Calibration System for Hypersonic Wind Tunnels
NASA Technical Reports Server (NTRS)
Green, Del L.; Everhart, Joel L.; Rhode, Matthew N.
2004-01-01
Minimization of uncertainty is essential for accurate ESP measurements at very low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources requires a well defined and controlled calibration method. A calibration system has been constructed and environmental control software developed to control experimentation to eliminate human induced error sources. The initial stability study of the calibration system shows a high degree of measurement accuracy and precision in temperature and pressure control. Control manometer drift and reference pressure instabilities induce uncertainty into the repeatability of voltage responses measured from the PSI System 8400 between calibrations. Methods of improving repeatability are possible through software programming and further experimentation.
Sun, Zhengming; Wang, Xiaoqing; Ling, Ming; Wang, Wei; Chang, Yanhai; Yang, Guang; Dong, Xianghui; Wu, Shixun; Wu, Xueyuan; Yang, Bo; Chen, Ming
2017-04-18
The purpose of this study was to test effects of negative pressure on tendon-bone healing after reconstruction of anterior cruciate ligament (ACL) in rabbits. Hind legs of 24 New Zealand White rabbits were randomly selected as negative pressure group and the contralateral hind legs as control. Reconstruction of the ACL was done. Joints of the negative pressure side were placed with drainage tubes connecting the micro-negative pressure aspirator. Control side was placed with ordinary drainage tubes. Drainage tubes on both sides were removed at the same time 5 days after operation. After 6 weeks, joint fluid was drawn to detect the expression levels of interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α); at the same time, femur-ligament-tibia complex was obtained to determine tendon graft tension and to observe the histomorphology, blood vessels of the tendon-bone interface, and expression of vascular endothelial growth factor (VEGF). The maximum load breakage of tendon graft was significantly greater in the negative pressure group than in the control group (P < 0.05). Histological studies of the tendon-bone interface found that there was more new bone formation containing chondroid cells and aligned connective tissue in the negative pressure group than in the control group. Expression of VEGF was higher in the negative pressure group than in the control group (P < 0.01). Content of IL-1β and TNF-α in synovial fluid is lower in the negative pressure group than in the control group (P < 0.01). Intermittent negative pressure plays an active role in tendon-bone healing and creeping substitution of ACL reconstruction in the rabbits.
Von Renteln-Kruse, W; Krause, T; Anders, J; Kühl, M; Heinemann, A; Püschel, K
2004-04-01
Some old persons at risk do develop, but others, at comparable risk, do not develop high-grade pressure sores. To evaluate potentially different risk factors, we performed a post mortem case-control study in old persons who developed high-grade pressure sores within six months until 14 days before death. Consecutive cases with pressure sores grade >/=3 and potential controls at comparably high risk for pressure sores were examined before cremation. After written informed consent had been obtained by the next relatives, all available nursing and medical records of the deceased were thoroughly evaluated. Cases and controls were matched according to age, gender, immobility, and cachexia.A total of 100 cases with 71 pressure sores grade 3 and 29 pressure sores grade 4 were compared to 100 controls with 27 pressure sores grade =2 and maximal risk as assessed by the Norton scale. The mean age was 86 years, 80% were females, 86% were bedridden, and cachexia was found in 66%. The cases were more often seriously disabled, had more often contractions of joints, and were on more drugs with intended or unwanted depressive/sedative effects (neuroleptics, benzodiazepines, centrally acting analgesics). Patient's impaired ability or low intention to comply/cooperate with preventive and/or therapeutic measures was more often recorded in cases than controls.A high degree of disablement and immobility, in particular, are risk factors for high-grade pressure sores in frail older high-risk persons. Sedative drug effects and impaired patient compliance with preventive and therapeutic measures may also be associated with the development of high-grade pressure sores in old persons at high risk.
Control of shock-wave boundary layer interaction using steady micro-jets
NASA Astrophysics Data System (ADS)
Verma, S. B.; Manisankar, C.; Akshara, P.
2015-09-01
An experimental investigation was conducted to control the amplitude of shock unsteadiness associated with the interaction induced by a cylindrical protuberance on a flat plate in a Mach 2.18 flow. The control was applied in the form of an array of steady micro air-jets of different configurations with variation in pitch and skew angle of the jets. The effect of air-jet supply pressure on control was also studied. Each of the micro-jet configurations was placed 20 boundary layer thicknesses upstream of the leading edge of the cylinder. The overall interaction is seen to get modified for all control configurations and shows a reduction in both separation- and bow-shock strengths and in triple-point height. A significant reduction in the peak rms value is also observed in the intermittent region of separation for each case. For pitched jets placed in a zig-zag configuration, good control effectiveness is achieved at control pressures similar to the stagnation pressure of the freestream. At higher control pressures, however, their obstruction component increases and if these jets are not spaced sufficiently far apart, the effectiveness of their control begins to drop due to the beginning of spanwise jet-to-jet interaction. On the other hand, pitching or skewing the jets to reduces the obstruction component considerably which at lower control pressures shows lower effectiveness. But at higher control pressure, the effectiveness of these configurations continues to increase unlike the pitched jets.
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2013 CFR
2013-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2014 CFR
2014-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2012 CFR
2012-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2011 CFR
2011-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
Churches as High Blood Pressure Control Centers
Kong, B. Wayne; Miller, Joseph M.; Smoot, Roland T.
1982-01-01
High blood pressure, a severe medical problem in the black community, can be controlled to a significant degree by proper medication. Discovery of hypertension and continuing thereapy, however, are difficult. The establishment of churches as high blood pressure control centers is a promising approach to overcome these deficits. The initial experiences with the creation of such a program are presented.
1997-05-01
Control Butterfly Hi-Pressure High Flow Control Butterfly Ejector Primary Clycol Control Valve Scrubber Fan Pressure Control Butterfly 8" Venturi ...the scrubber . 20 ■ SCRUBBER FAN BLOWER INLET VALVE VP-2 VP-3 VP-4 VP-5 VP-6 VP-7 VP-8 VP-9 VP-10 SV-1 SV-2 DESCRIPTION Atmospheric...Blower Bypass Butterfly 24" Venturi Control Butterfly 24" Test Section Exit Butterfly Ejector 10’ Secondary Inlet-Butterfly Hi-pressure Low Flow
Exhaust gas bypass valve control for thermoelectric generator
Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan
2012-09-04
A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.
Measuring Pressure Has a New Standard
NASA Technical Reports Server (NTRS)
2002-01-01
The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.
Effects of Oxygen Partial Pressure on the Surface Tension of Liquid Nickel
NASA Technical Reports Server (NTRS)
SanSoucie, Michael P.; Rogers, Jan R.; Gowda, Vijaya Kumar Malahalli Shankare; Rodriguez, Justin; Matson, Douglas M.
2015-01-01
The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has been recently upgraded with an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10-36 to 100 bar. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte, which is yttria-stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, PID-based current loop, and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects of oxygen partial pressure on the surface tension of undercooled liquid nickel will be analyzed, and the results will be presented. The surface tension will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension will be measured using the oscillating drop method. While undercooled, each sample will be oscillated several times consecutively to investigate how the surface tension behaves with time while at a particular oxygen partial pressure.
Pengpid, Supa; Peltzer, Karl; Skaal, Linda
2014-06-06
In persons 15 years and above in South Africa the prevalence of pre-diabetes and diabetes has been estimated at 9.1% and 9.6%, respectively, and the prevalence of systolic prehypertension and hypertension, 38.2% and 24.6%, respectively. Elevated blood glucose and elevated blood pressure are prototype of preventable chronic cardiovascular disease risk factors.Lifestyle interventions have been shown to control high normal blood pressure and/or high normal blood glucose. This study proposes to evaluate the efficacy of a community (church)-based lifestyle intervention programme to control high normal blood pressure and/or high normal blood glucose in church members in a randomized controlled trial in Gauteng, South Africa. The objectives are to: (1) measure non-communicable diseases profile, including hypertension and diabetes, health behaviours, weight management and psychological distress of church members; (2) measure the reduction of blood glucose and blood pressure levels after the intervention; (3) prevent the development of impaired glucose tolerance; (4) compare health behaviours, weight management and psychological distress, blood glucose and blood pressure levels between intervention and control groups, and within group during 6, 12, 24 and 36 months during and post intervention. The study will use a group-randomized design, recruiting 300 church members from 12 churches. Churches will be randomly assigned to experimental and control conditions. Lifestyle interventions may prevent from the development of high blood pressure and/or diabetes. The findings will impact public health and will enable the health ministry to formulate policy related to lifestyle interventions to control blood pressure and glucose. PACTR201105000297151.
Vu, Maihan B.; Halladay, Jacqueline R.; Miller, Cassandra; Garcia, Beverly A.; Cummings, Doyle M.; Cene, Crystal W.; Hinderliter, Alan; Little, Edwin; Rachide, Marjorie; DeWalt, Darren
2014-01-01
Introduction Patient and practice perspectives can inform development of team-based approaches to improving blood pressure control in primary care. We used a community-based participatory research approach to assess patient and practice perceptions regarding the value of team-based strategies for controlling blood pressure in a rural North Carolina population from 2010 through 2012. Methods In-depth interviews were conducted with 41 adults with hypertension, purposely sampled to include diversity of sex, race, literacy, and blood pressure control, and with key office staff at 5 rural primary care practices in the southeastern US “stroke belt.” Interviews explored barriers to controlling blood pressure, the practice’s role in controlling blood pressure, and opinions on the use of team care delivery. Results Patients reported that provider strategies to optimize blood pressure control should include regular visits, medication adjustment, side-effect discussion, and behavioral counseling. When discussing team-based approaches to hypertension care, patients valued verbal encouragement, calls from the doctor’s office, and the opportunity to ask questions. However, they voiced concerns about the effect of having too many people involved in their care. Practice staff focused on multiple, broad methods to control blood pressure including counseling, regular office visits, media to improve awareness, and support groups. An explicit focus of delivering care as teams was a newer concept. Conclusion When developing a team approach to hypertension treatment, patients value high-quality communication and not losing their primary relationship with their provider. Practice staff members were open to a team-based approach but had limited knowledge of what such an approach would entail. PMID:24762533
Ocular perfusion pressure control during pars plana vitrectomy: testing a novel device.
Rossi, Tommaso; Querzoli, Giorgio; Gelso, Aldo; Angelini, Giampiero; Rossi, Alessandro; Corazza, Paolo; Landi, Laura; Telani, Serena; Ripandelli, Guido
2017-12-01
To study the efficacy of a novel device intended to control infusion pressure based on mean ocular perfusion pressure (MOPP) during pars plana vitrectomy (PPV). An arm blood pressure cuff connected to a vitrectomy machine calculated mean arterial pressure (MAP), while a pressure sensor close to the infusion trocar measured intraocular pressure (IOP). MOPP was calculated in real time in 36 consecutive patients undergoing PPV, who were divided into two groups. The device lowered IOP every time that calculated MOPP fell below 30 mmHg in the Control ON group (18 patients), while no action was taken in the Control OFF group (18 patients). Baseline IOP and blood pressure were similar between groups. The Control ON group had significantly lower average intraoperative IOP (30.5 ± 2.1 vs. 35.9 ± 6.9 mmHg; p = 0.002) and higher MOPP (56.4 ± 5.9 vs. 49.7 ± 6.1 mmHg) than the Control OFF group. The Control ON group also spent less time at MOPP < 10 mmHg and < 30 mmHg: 0 vs. 3.40 ± 2.38 min (p < 0.001) and 9.91 ± 7.15 vs. 16.13 ± 8.12 min (p = 0.02), respectively. The MOPP control device effectively maintained lower IOP and higher MOPP throughout surgery. It also helped avoid dangerous IOP peaks and MOPP dips, allowing patients to spend less time at MOPP of < 10 and < 30 mmHg.
Pressure control valve. [inflating flexible bladders
NASA Technical Reports Server (NTRS)
Lambson, K. H. (Inventor)
1980-01-01
A control valve is provided which is adapted to be connected between a pressure source, such as a vacuum pump, and a pressure vessel so as to control the pressure in the vessel. The valve comprises a housing having a longitudinal bore which is connected between the pump and vessel, and a transversely movable valve body which controls the air flow through an air inlet in the housing. The valve body includes cylindrical and conical shaped portions which cooperate with reciprocally shaped portions of the housing to provide flow control. A filter in the air inlet removes foreign matter from the air. The bottom end of the valve body is screwed into the valve housing control knob formed integrally with the valve body and controls translation of the valve body, and the opening and closing of the valve.
NASA Technical Reports Server (NTRS)
Joerns, J. C.
1986-01-01
Pressure regulated and flow timed to control amount dispensed. Dispenser provides measured amount of water for reconstituting dehydrated foods and beverages. Dispenser holds food or beverage package while being filled with either cold or room-temperature water. Other uses might include dispensing of fluids or medicine. Pressure regulator in dispenser reduces varying pressure of water supply to constant pressure. Electronic timer stops flow after predetermined length of time. Timed flow at regulated pressure ensures controlled volume of water dispensed.
NASA Technical Reports Server (NTRS)
Simon, Richard A.
1987-01-01
Simulation circuit operates under remote, automatic, or manual control to produce electrical outputs similar to pressure transducer. Specific circuit designed for simulations of Space Shuttle main engine. General circuit concept adaptable to other simulation and control systems involving several operating modes. Switches and amplifiers respond to external control signals and panel control settings to vary differential excitation of resistive bridge. Output voltage or passive terminal resistance made to equal pressure transducer in any of four operating modes.
A temperature and pressure controlled calibration system for pressure sensors
NASA Technical Reports Server (NTRS)
Chapman, John J.; Kahng, Seun K.
1989-01-01
A data acquisition and experiment control system capable of simulating temperatures from -184 to +220 C and pressures either absolute or differential from 0 to 344.74 kPa is developed to characterize silicon pressure sensor response to temperature and pressure. System software is described that includes sensor data acquisition, algorithms for numerically derived thermal offset and sensitivity correction, and operation of the environmental chamber and pressure standard. This system is shown to be capable of computer interfaced cryogenic testing to within 1 C and 34.47 Pa of single channel or multiplexed arrays of silicon pressure sensors.
System and method for bidirectional flow and controlling fluid flow in a conduit
Ortiz, Marcos German
1999-01-01
A system for measuring bidirectional flow, including backflow, of fluid in a conduit. The system utilizes a structural mechanism to create a pressure differential in the conduit. Pressure sensors are positioned upstream from the mechanism, at the mechanism, and downstream from the mechanism. Data from the pressure sensors are transmitted to a microprocessor or computer, and pressure differential detected between the pressure sensors is then used to calculate the backflow. Control signals may then be generated by the microprocessor or computer to shut off valves located in the conduit, upon the occurrence of backflow, or to control flow, total material dispersed, etc. in the conduit.
Pressure intelligent control strategy of Waste heat recovery system of converter vapors
NASA Astrophysics Data System (ADS)
Feng, Xugang; Wu, Zhiwei; Zhang, Jiayan; Qian, Hong
2013-01-01
The converter gas evaporative cooling system is mainly used for absorbing heat in the high temperature exhaust gas which produced by the oxygen blowing reaction. Vaporization cooling steam pressure control system of converter is a nonlinear, time-varying, lagging behind, close coupling of multivariable control object. This article based on the analysis of converter operation characteristics of evaporation cooling system, of vaporization in a production run of pipe pressure variation and disturbance factors.For the dynamic characteristics of the controlled objects,we have improved the conventional PID control scheme.In Oxygen blowing process, we make intelligent control by using fuzzy-PID cascade control method and adjusting the Lance,that it can realize the optimization of the boiler steam pressure control.By design simulation, results show that the design has a good control not only ensures drum steam pressure in the context of security, enabling efficient conversion of waste heat.And the converter of 1800 flue gas through pipes and cool and dust removal also can be cooled to about 800. Therefore the converter haze evaporative cooling system has achieved to the converter haze temperature decrease effect and enhanced to the coal gas returns-ratio.
Demarré, L; Beeckman, D; Vanderwee, K; Defloor, T; Grypdonck, M; Verhaeghe, S
2012-04-01
The duration and the amount of pressure and shear must be reduced in order to minimize the risk of pressure ulcer development. Alternating low pressure air mattresses with multi-stage inflation and deflation cycle of the air cells have been developed to relieve pressure by sequentially inflating and deflating the air cells. Evidence about the effectiveness of this type of mattress in clinical practice is lacking. This study aimed to compare the effectiveness of an alternating low pressure air mattress that has a standard single-stage inflation and deflation cycle of the air cells with an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. A randomised controlled trial was performed in a convenience sample of 25 wards in five hospitals in Belgium. In total, 610 patients were included and randomly assigned to the experimental group (n=298) or the control group (n=312). In the experimental group, patients were allocated to an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. In the control group, patients were allocated to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. The outcome was defined as cumulative pressure ulcer incidence (Grade II-IV). An intention-to-treat analysis was performed. There was no significant difference in cumulative pressure ulcer incidence (Grade II-IV) between both groups (Exp.=5.7%, Contr.=5.8%, p=0.97). When patients developed a pressure ulcer, the median time was 5.0 days in the experimental group (IQR=3.0-8.5) and 8.0 days in the control group (IQR=3.0-8.5) (Mann-Whitney U-test=113, p=0.182). The probability to remain pressure ulcer free during the observation period in this trial did not differ significantly between the experimental group and the control group (log-rank χ(2)=0.013, df=1, p=0.911). An alternating low pressure air mattress with multi-stage inflation and deflation of the air cells does not result in a significantly lower pressure ulcer incidence compared to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. Both alternating mattress types are equally effective to prevent pressure ulcer development. © 2011 Elsevier Ltd. All rights reserved.
Control of pseudo-shock oscillation in scramjet inlet-isolator using periodical excitation
NASA Astrophysics Data System (ADS)
Su, Wei-Yi; Chen, Yun; Zhang, Feng-Rui; Tang, Piao-Ping
2018-02-01
To suppress the pressure oscillation, stabilize the shock train in the scramjet isolator and delay the hypersonic inlet unstart, flow control using periodic excitation was investigated with unsteady Reynolds averaged Navier-Stokes simulations. The results showed that by injecting air to manipulate the cowl reflected shock wave, the separation bubble induced by it was diminished and the pressure oscillations of the shock train were markedly suppressed. The power spectral density and standard deviation of wall pressure were significantly reduced. The simulations revealed that this active control method can raise the critical back pressure by 17.5% compared with the baseline, which would successfully delay the hypersonic inlet unstarts. The results demonstrated that this active control method is effective in suppressing pressure oscillation and delaying hypersonic inlet unstarts.
Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization
NASA Technical Reports Server (NTRS)
VanDresar, Neil T.
2014-01-01
This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank ullage, and combined use of the axial jet and spray hoops. A submerged liquid pump and compact heat exchanger located inside the test tank were used with all the mixer configurations. The initial series without helium and the final series with liquid nitrogen both used the axial jet mixer. The axial jet configuration successfully demonstrated the ability to control tank pressure; but in the normal-gravity environment, the temperature in the upper tank region (ullage and unwetted wall) was not controlled. The spray hoops and axial jet combination also successfully demonstrated pressure control as well as temperature control of the entire tank and contents. The spray-hoops-only configuration was not expected to be a reliable means of tank mixing because there was no direct means to produce liquid circulation. However, surprisingly good results also were obtained with the sprayhoops- only configuration (i.e., performance metrics such as cycle-averaged vent flowrate were similar to those obtained with the other configurations). A simple thermodynamic model was developed that correctly predicted the TVS behavior (temperature rise or pressure drop per TVS cycle) when helium was present in the ullage. The model predictions were correlated over a range of input parameters. The correlations show that temperature rise or pressure drop per cycle was proportional to both helium mole fraction and tank heat input. The response also depended on the tank fill fraction: the temperature rise or pressure drop (per TVS cycle) increased as the ullage volume decreased.
Intensive Blood-Pressure Control in Hypertensive Chronic Kidney Disease
Appel, Lawrence J.; Wright, Jackson T.; Greene, Tom; Agodoa, Lawrence Y.; Astor, Brad C.; Bakris, George L.; Cleveland, William H.; Charleston, Jeanne; Contreras, Gabriel; Faulkner, Marquetta L.; Gabbai, Francis B.; Gassman, Jennifer J.; Hebert, Lee A.; Jamerson, Kenneth A.; Kopple, Joel D.; Kusek, John W.; Lash, James P.; Lea, Janice P.; Lewis, Julia B.; Lipkowitz, Michael S.; Massry, Shaul G.; Miller, Edgar R.; Norris, Keith; Phillips, Robert A.; Pogue, Velvie A.; Randall, Otelio S.; Rostand, Stephen G.; Smogorzewski, Miroslaw J.; Toto, Robert D.; Wang, Xuelei
2013-01-01
BACKGROUND In observational studies, the relationship between blood pressure and end-stage renal disease (ESRD) is direct and progressive. The burden of hypertension-related chronic kidney disease and ESRD is especially high among black patients. Yet few trials have tested whether intensive blood-pressure control retards the progression of chronic kidney disease among black patients. METHODS We randomly assigned 1094 black patients with hypertensive chronic kidney disease to receive either intensive or standard blood-pressure control. After completing the trial phase, patients were invited to enroll in a cohort phase in which the blood-pressure target was less than 130/80 mm Hg. The primary clinical outcome in the cohort phase was the progression of chronic kidney disease, which was defined as a doubling of the serum creatinine level, a diagnosis of ESRD, or death. Follow-up ranged from 8.8 to 12.2 years. RESULTS During the trial phase, the mean blood pressure was 130/78 mm Hg in the intensive-control group and 141/86 mm Hg in the standard-control group. During the cohort phase, corresponding mean blood pressures were 131/78 mm Hg and 134/78 mm Hg. In both phases, there was no significant between-group difference in the risk of the primary outcome (hazard ratio in the intensive-control group, 0.91; P = 0.27). However, the effects differed according to the baseline level of proteinuria (P = 0.02 for interaction), with a potential benefit in patients with a protein-to-creatinine ratio of more than 0.22 (hazard ratio, 0.73; P = 0.01). CONCLUSIONS In overall analyses, intensive blood-pressure control had no effect on kidney disease progression. However, there may be differential effects of intensive blood-pressure control in patients with and those without baseline proteinuria. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases, the National Center on Minority Health and Health Disparities, and others.) PMID:20818902
How Potassium Can Help Control High Blood Pressure
... Aortic Aneurysm More How Potassium Can Help Control High Blood Pressure Updated:Jan 29,2018 Understanding the heart-healthy ... tips . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...
Pressure fluctuations and time scales in turbulent channel flow
NASA Astrophysics Data System (ADS)
Septham, Kamthon; Morrison, Jonathan; Diwan, Sourabh
2015-11-01
Pressure fluctuations in turbulent channel flow subjected to globally stabilising linear feedback control are investigated at Reτ = 400 . The passivity-based control is adopted and explained by the conservative characteristics of the nonlinear terms contributing to the Reynolds-Orr equation (Sharma et al. Phys. Fluids 2011). The linear control operates via vU' ; the maximum forcing is located at y+ ~ 20 , corresponding to the location of the maximum in the mean-square pressure gradient. The responses of the rapid (linear) and slow (nonlinear) pressure fluctuations to the linear control are investigated using the Green's function representations. It demonstrates that the linear control operates via the linear source terms of the Poisson equation for pressure fluctuations. Landahl's timescales of the minimal flow unit (MFU) in turbulent channel flow are examined at y+ = 20 . It shows that the timescales of MFU agree well with the theoretical values proposed by Landahl (1993). Therefore, the effectiveness of the linear control to attenuate wall turbulence is explained by Landahl's theory for timescales, in that the control proceeds via the shear interaction timescale which is significantly shorter than both the nonlinear and viscous timescales.
Luque-Ramírez, Manuel; Alvarez-Blasco, Francisco; Mendieta-Azcona, Covadonga; Botella-Carretero, José I; Escobar-Morreale, Héctor F
2007-06-01
Obesity and insulin resistance predispose patients with the polycystic ovary syndrome (PCOS) to abnormalities in blood pressure regulation. Our objective was to evaluate the impact of obesity on the blood pressure profiles of PCOS patients. PATIENTS, SETTING, AND DESIGN: Thirty-six PCOS patients and 20 healthy women participated in a case-control study at an academic hospital. We conducted ambulatory blood pressure monitoring and office blood pressure determinations. Hypertension (defined as increased office blood pressure confirmed by ambulatory blood pressure monitoring or by masked hypertension) was present in 12 PCOS patients and eight controls (P = 0.618). No differences between patients and controls were found in office and ambulatory blood pressure monitoring values and heart rate, yet the nocturnal decrease in mean blood pressure was smaller in patients (P = 0.038). Obese women (13 patients and eight controls) had increased frequencies of office hypertension (29% compared with 3% in lean plus overweight women, P = 0.005), increased diastolic (P = 0.009) and mean (P = 0.015) office blood pressure values, and increased heart rate values during the daytime (P = 0.038), nighttime (P = 0.002), and 24-h (P = 0.009) periods, independently of having PCOS or not. The frequency of a nocturnal nondipper pattern was 62% in obese PCOS patients, compared with 26% in lean plus overweight PCOS patients (P = 0.036) and 25% in obese and in lean plus overweight controls. Abnormalities in the regulation of blood pressure are common in young women with PCOS, yet, with the exception of the nondipper pattern, these abnormalities result from the frequent association of this syndrome with obesity.
Fernando, Malindu E.; Crowther, Robert G.; Lazzarini, Peter A.; Yogakanthi, Saiumaeswar; Sangla, Kunwarjit S.; Buttner, Petra; Jones, Rhondda; Golledge, Jonathan
2017-01-01
Objective High plantar pressures are implicated in the development of diabetes-related foot ulcers. Whether plantar pressures remain high in patients with chronic diabetes-related foot ulcers over time is uncertain. The primary aim of this study was to compare plantar pressures at baseline and three and six months later in participants with chronic diabetes-related foot ulcers (cases) to participants without foot ulcers (controls). Methods Standardised protocols were used to measure mean peak plantar pressure and pressure-time integral at 10 plantar foot sites (the hallux, toes, metatarsals 1 to 5, mid-foot, medial heel and lateral heel) during barefoot walking. Measurements were performed at three study visits: baseline, three and six months. Linear mixed effects random-intercept models were utilised to assess whether plantar pressures differed between cases and controls after adjusting for age, sex, body mass index, neuropathy status and follow-up time. Standardised mean differences (Cohen’s d) were used to measure effect size. Results Twenty-one cases and 69 controls started the study and 16 cases and 63 controls completed the study. Cases had a higher mean peak plantar pressure at several foot sites including the toes (p = 0.005, Cohen’s d = 0.36) and mid-foot (p = 0.01, d = 0.36) and a higher pressure-time integral at the hallux (p<0.001, d = 0.42), metatarsal 1 (p = 0.02, d = 0.33) and mid-foot (p = 0.04, d = 0.64) compared to controls throughout follow-up. A reduction in pressure-time integral at multiple plantar sites over time was detected in all participants (p<0.05, respectively). Conclusions Plantar pressures assessed during gait are higher in diabetes patients with chronic foot ulcers than controls at several plantar sites throughout prolonged follow-up. Long term offloading is needed in diabetes patients with diabetes-related foot ulcers to facilitate ulcer healing. PMID:28859075
Derby, Richard; Lee, Sang Hoon; Lee, Jeong-Eun; Lee, Sang-Heon
2011-01-01
The study compares the rate of positive discograms using an automated versus a manual pressure-controlled injection devise and compares the pressure and volume values at various pressures and initial evoked pain and 6/10 or greater evoked pain. A retrospective study prospectively collected patient study data used in a prior prospective study and with prospectively collected data which is routinely collected per our institutional standardized audit protocol. Two custom-built disc manometers (automated injection speed control; manual injection speed control) were sequentially employed during provocation discography in 510 discs of 151 consecutive patients. Two hundred thirty-seven discs of 67 patients with chronic low back pain were evaluated using the automated manometer (automated group) and 273 discs of 84 patients were evaluated with a manual manometer (manual group). No significant differences in positive discogram rates were found between the automated and manual groups (32.1% vs 32.6% per disc, respectively, P>0.05). No significant differences in low-pressure positive discogram rates were found (16.0% vs 15.0% per disc, automated group versus manual group, respectively, P>0.05). However, there were significantly increased volumes and lower pressures at initial and "bad" pain provocation. The study results found equivalent positive discogram rates following a series of pressure-controlled discography using either an automated or manual pressure devise. There were, however significant increases in volume at both initial onset of evoked pain and at 6/10 pain when using the automated injection devise that may have caused the observed lower opening pressure and lower pressure values at initial evoked pain. Assuming increased volumes are innocuous, automated injection is inherently more controlled and may better reduce unintended and often unrecorded spurious high dynamic pressure peaks thereby reducing conscious and unconscious operator bias. Wiley Periodicals, Inc.
Dasinger, John Henry; Intapad, Suttira; Backstrom, Miles A.; Carter, Anthony J.
2016-01-01
Placental insufficiency programs an increase in blood pressure associated with a twofold increase in serum testosterone in male growth-restricted offspring at 4 mo of age. Population studies indicate that the inverse relationship between birth weight and blood pressure is amplified with age. Thus, we tested the hypothesis that intrauterine growth restriction programs an age-related increase in blood pressure in male offspring. Growth-restricted offspring retained a significantly higher blood pressure at 12 but not at 18 mo of age compared with age-matched controls. Blood pressure was significantly increased in control offspring at 18 mo of age relative to control counterparts at 12 mo; however, blood pressure was not increased in growth-restricted at 18 mo relative to growth-restricted counterparts at 12 mo. Serum testosterone levels were not elevated in growth-restricted offspring relative to control at 12 mo of age. Thus, male growth-restricted offspring no longer exhibited a positive association between blood pressure and testosterone at 12 mo of age. Unlike hypertension in male growth-restricted offspring at 4 mo of age, inhibition of the renin-angiotensin system with enalapril (250 mg/l for 2 wk) did not abolish the difference in blood pressure in growth-restricted offspring relative to control counterparts at 12 mo of age. Therefore, these data suggest that intrauterine growth restriction programs an accelerated age-related increase in blood pressure in growth-restricted offspring. Furthermore, this study suggests that the etiology of increased blood pressure in male growth-restricted offspring at 12 mo of age differs from that at 4 mo of age. PMID:27147668
Quality Management and Control of Low Pressure Cast Aluminum Alloy
NASA Astrophysics Data System (ADS)
Zhang, Dianxi; Zhang, Yanbo; Yang, Xiufan; Chen, Zhaosong; Jiang, Zelan
2018-01-01
This paper briefly reviews the history of low pressure casting and summarizes the major production processes of low pressure casting. It briefly introduces the quality management and control of low pressure cast aluminum alloy. The main processes include are: preparation of raw materials, Melting, refining, physical and chemical analysis, K-mode inspection, sand core, mold, heat treatment and so on.
Intermittent pressure decreases human keratinocyte proliferation in vitro.
Nasca, Maria R; Shih, Alan T; West, Dennis P; Martinez, Wanda M; Micali, Giuseppe; Landsman, Adam S
2007-01-01
The aim of this study was to investigate the correlation between pressure changes and keratinocyte proliferation by determining whether keratinocytes exposed to altered mechanical pressures would proliferate at different rates compared to control cells not subjected to pressure changes. Tissue culture flasks of human keratinocytes plated at an approximate density of 15,000 cells/cm(2) undergoing an intermittent cyclic pressure of 362 mm Hg at a frequency of 2.28 or 5.16 cycles/min (0.038 or 0.086 Hz) for 8 h were compared to control flasks grown at ambient room pressure. An in-line pressure transducer was used to monitor and adjust pressure within the cell chambers, using a solenoid valve. A thymidine incorporation assay assessed the amount of cell proliferation in each set of experiments. Differences in proliferation between keratinocytes subjected to cyclic pressure changes and control cells were found to be statistically significant (p < 0.05) in 4 out of 5 proliferation assays. Also, a higher frequency of pressure changes consistently generated a reduced proliferation rate compared to that seen in cells exposed to a lower frequency of pressure changes. These data indicate that keratinocytes undergoing intermittent pressure changes exhibit decreased proliferation rates compared to controls. Furthermore, an increased frequency rate seems to have a greater effect on proliferation than low-frequency rate pressure changes, suggesting that the stress caused by frequently changed pressure may play a greater role in reducing keratinocyte proliferation than the actual magnitude of load applied to the cells. Our results support the current treatment protocol of reducing speed and duration of walking on the site of the wound to promote healing of foot ulcers. (c) 2007 S. Karger AG, Basel.
Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes.
Kuo, Chung-Hsien; Wu, Chun-Ju; Chou, Hung-Chyun; Chen, Guan-Ting; Kuo, Yu-Cheng
2017-01-01
This paper presents an oscillometric blood pressure (BP) measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP) and diastolic blood pressure (DBP), during the inflating cycle. Two modes of air injection measurement (AIM) and accurate dual-way measurement (ADM) were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation) in the measurements when compared to a commercial BP monitor.
NASA Technical Reports Server (NTRS)
Libby, W. F.; Jensen, C. A.; Wood, L. L. (Inventor)
1977-01-01
The apparatus includes a housing for confining a gas at subatmospheric pressure and including a set of reflectors defining an optical cavity. At least one anode and cathode are positioned within the gas. First control means control the voltage applied to the anode and second control means independently control the temperature of the cathode. The pressure of the gas is controlled by a third control means. An intense monochromatic output is achieved by confining the gas in the housing at a controlled pre-determined reduced pressure, independently controlling the temperature of the electron emitting cathode and applying predetermined controlled low voltage to the anode.
Active Control of Combustor Instability Shown to Help Lower Emissions
NASA Technical Reports Server (NTRS)
DeLaat, John C.; Chang, Clarence T.
2002-01-01
In a quest to reduce the environmental impact of aerospace propulsion systems, extensive research is being done in the development of lean-burning (low fuel-to-air ratio) combustors that can reduce emissions throughout the mission cycle. However, these lean-burning combustors have an increased susceptibility to thermoacoustic instabilities, or high-pressure oscillations much like sound waves, that can cause severe high-frequency vibrations in the combustor. These pressure waves can fatigue the combustor components and even the downstream turbine blades. This can significantly decrease the safe operating life of the combustor and turbine. Thus, suppression of the thermoacoustic combustor instabilities is an enabling technology for lean, low-emissions combustors. Under the Aerospace Propulsion and Power Base Research and Technology Program, the NASA Glenn Research Center, in partnership with Pratt & Whitney and United Technologies Research Center, is developing technologies for the active control of combustion instabilities. With active combustion control, the fuel is pulsed to put pressure oscillations into the system. This cancels out the pressure oscillations being produced by the instabilities. Thus, the engine can have lower pollutant emissions and long life.The use of active combustion instability control to reduce thermo-acoustic-driven combustor pressure oscillations was demonstrated on a single-nozzle combustor rig at United Technologies. This rig has many of the complexities of a real engine combustor (i.e., an actual fuel nozzle and swirler, dilution cooling, etc.). Control was demonstrated through modeling, developing, and testing a fuel-delivery system able to the 280-Hz instability frequency. The preceding figure shows the capability of this system to provide high-frequency fuel modulations. Because of the high-shear contrarotating airflow in the fuel injector, there was some concern that the fuel pulses would be attenuated to the point where they would not be effective for control. Testing in the combustor rig showed that open-loop pulsing of the fuel was, in fact, able to effectively modulate the combustor pressure. To suppress the combustor pressure oscillations due to thermoacoustic instabilities, it is desirable to time the injection of the fuel so that it interferes with the instability. A closed-loop control scheme was developed that uses combustion pressure feedback and a phase-shifting controller to time the fuel-injection pulses. Some suppression of the pressure oscillations at the 280-Hz instability frequency was demonstrated (see the next figure). However, the overall peak-to- peak pressure oscillations in the combustor were only mildly reduced. Improvements to control hardware and control methods are being continued to gain improved closed-loop reduction of the pressure oscillations.pulse the fuel at
Experimenting With Baroreceptor Reflexes
NASA Technical Reports Server (NTRS)
Eckberg, Dwain L.; Goble, Ross L.
1988-01-01
Carotid arteries stimulated by pressure or suction on neck. Baro-Cuff is silicone-rubber chamber that fits on front of subject's neck. Electronic system, stepping motor, bellows, and umbilical tube furnish controlled pressure to chamber. Pressure sensor provides feedback to microprocessor in electronic system. Developed to study blood-pressure-reflex responses of astronauts in outer space. Useful for terrestrial studies of patients with congestive heart failure, chronic diabetes mellitus, and other conditions in which blood-pressure-reflex controls behave abnormally.
A model-based gain scheduling approach for controlling the common-rail system for GDI engines
NASA Astrophysics Data System (ADS)
di Gaeta, Alessandro; Montanaro, Umberto; Fiengo, Giovanni; Palladino, Angelo; Giglio, Veniero
2012-04-01
The progressive reduction in vehicle emission requirements have forced the automotive industry to invest in research for developing alternative and more efficient control strategies. All control features and resources are permanently active in an electronic control unit (ECU), ensuring the best performance with respect to emissions, fuel economy, driveability and diagnostics, independently from engine working point. In this article, a considerable step forward has been achieved by the common-rail technology which has made possible to vary the injection pressure over the entire engine speed range. As a consequence, the injection of a fixed amount of fuel is more precise and multiple injections in a combustion cycle can be made. In this article, a novel gain scheduling pressure controller for gasoline direct injection (GDI) engine is designed to stabilise the mean fuel pressure into the rail and to track demanded pressure trajectories. By exploiting a simple control-oriented model describing the mean pressure dynamics in the rail, the control structure turns to be simple enough to be effectively implemented in commercial ECUs. Experimental results in a wide range of operating points confirm the effectiveness of the proposed control method to tame efficiently the mean value pressure dynamics of the plant showing a good accuracy and robustness with respect to unavoidable parameters uncertainties, unmodelled dynamics, and hidden coupling terms.
Su, Tin Tin; Majid, Hazreen Abdul; Nahar, Azmi Mohamed; Azizan, Nurul Ain; Hairi, Farizah Mohd; Thangiah, Nithiah; Dahlui, Maznah; Bulgiba, Awang; Murray, Liam J
2014-01-01
Death rates due to hypertension in low and middle income countries are higher compared to high income countries. The present study is designed to combine life style modification and home blood pressure monitoring for control of hypertension in the context of low and middle income countries. The study is a two armed, parallel group, un-blinded, cluster randomized controlled trial undertaken within lower income areas in Kuala Lumpur. Two housing complexes will be assigned to the intervention group and the other two housing complexes will be allocated in the control group. Based on power analysis, 320 participants will be recruited. The participants in the intervention group (n = 160) will undergo three main components in the intervention which are the peer support for home blood pressure monitoring, face to face health coaching on healthy diet and demonstration and training for indoor home based exercise activities while the control group will receive a pamphlet containing information on hypertension. The primary outcomes are systolic and diastolic blood pressure. Secondary outcome measures include practice of self-blood pressure monitoring, dietary intake, level of physical activity and physical fitness. The present study will evaluate the effect of lifestyle modification and peer support home blood pressure monitoring on blood pressure control, during a 6 month intervention period. Moreover, the study aims to assess whether these effects can be sustainable more than six months after the intervention has ended.
Simons, A P; Lindelauf, A A M A; Ganushchak, Y M; Maessen, J G; Weerwind, P W
2014-01-01
Without volume-buffering capacity in extracorporeal life support (ELS) systems, hypovolemia can acutely reduce support flow. This study aims at evaluating efficacy and safety of strategies for preserving stable ELS during hypovolemia. Flow and/or pressure-guided servo pump control, a reserve-driven control strategy and a volume buffer capacity (VBC) device were evaluated with respect to pump flow, venous line pressure and arterial gaseous microemboli (GME) during simulated normovolemia and hypovolemia. Normovolemia resulted in a GME-free pump flow of 3.1 ± 0.0 L/min and a venous line pressure of -10 ± 1 mmHg. Hypovolemia without servo pump control resulted in a GME-loaded flow of 2.3 ± 0.4 L/min with a venous line pressure of -114 ± 52 mmHg. Servo control resulted in an unstable and GME-loaded flow of 1.5 ± 1.2 L/min. With and without servo pump control, the VBC device stabilised flow (SD = 0.2 and 0.0 L/min, respectively) and venous line pressure (SD=51 and 4 mmHg, respectively) with near-absent GME activity. Reserve-driven pump control combined with a VBC device restored a near GME-free flow of 2.7 ± 0.0 L/min with a venous line pressure of -9 ± 0 mmHg. In contrast to a reserve-driven pump control strategy combined with a VBC device, flow and pressure servo control for ELS show evident deficits in preserving stable and safe ELS flow during hypovolemia.
Ephraim, Patti L.; Hill-Briggs, Felicia; Roter, Debra; Bone, Lee; Wolff, Jennifer; Lewis-Boyer, LaPricia; Levine, David; Aboumatar, Hanan; Cooper, Lisa A; Fitzpatrick, Stephanie; Gudzune, Kimberly; Albert, Michael; Monroe, Dwyan; Simmons, Michelle; Hickman, Debra; Purnell, Leon; Fisher, Annette; Matens, Richard; Noronha, Gary; Fagan, Peter; Ramamurthi, Hema; Ameling, Jessica; Charlston, Jeanne; Sam, Tanyka; Carson, Kathryn A.; Wang, Nae-Yuh; Crews, Deidra; Greer, Raquel; Sneed, Valerie; Flynn, Sarah J.; DePasquale, Nicole; Boulware, L. Ebony
2014-01-01
Background Given their high rates of uncontrolled blood pressure, urban African Americans comprise a particularly vulnerable subgroup of persons with hypertension. Substantial evidence has demonstrated the important role of family and community support in improving patients’ management of a variety of chronic illnesses. However, studies of multilevel interventions designed specifically to improve urban African American patients’ blood pressure self-management by simultaneously leveraging patient, family, and community strengths are lacking. Methods/Design We report the protocol of the Achieving Blood Pressure Control Together (ACT) study, a randomized controlled trial designed to study the effectiveness of interventions that engage patient, family, and community-level resources to facilitate urban African American hypertensive patients’ improved hypertension self-management and subsequent hypertension control. African American patients with uncontrolled hypertension receiving health care in an urban primary care clinic will be randomly assigned to receive 1) an educational intervention led by a community health worker alone, 2) the community health worker intervention plus a patient and family communication activation intervention, or 3) the community health worker intervention plus a problem-solving intervention. All participants enrolled in the study will receive and be trained to use a digital home blood pressure machine. The primary outcome of the randomized controlled trial will be patients’ blood pressure control at 12 months. Discussion Results from the ACT study will provide needed evidence on the effectiveness of comprehensive multi-level interventions to improve urban African American patients’ hypertension control. PMID:24956323
Ephraim, Patti L; Hill-Briggs, Felicia; Roter, Debra L; Bone, Lee R; Wolff, Jennifer L; Lewis-Boyer, LaPricia; Levine, David M; Aboumatar, Hanan J; Cooper, Lisa A; Fitzpatrick, Stephanie J; Gudzune, Kimberly A; Albert, Michael C; Monroe, Dwyan; Simmons, Michelle; Hickman, Debra; Purnell, Leon; Fisher, Annette; Matens, Richard; Noronha, Gary J; Fagan, Peter J; Ramamurthi, Hema C; Ameling, Jessica M; Charlston, Jeanne; Sam, Tanyka S; Carson, Kathryn A; Wang, Nae-Yuh; Crews, Deidra C; Greer, Raquel C; Sneed, Valerie; Flynn, Sarah J; DePasquale, Nicole; Boulware, L Ebony
2014-07-01
Given their high rates of uncontrolled blood pressure, urban African Americans comprise a particularly vulnerable subgroup of persons with hypertension. Substantial evidence has demonstrated the important role of family and community support in improving patients' management of a variety of chronic illnesses. However, studies of multi-level interventions designed specifically to improve urban African American patients' blood pressure self-management by simultaneously leveraging patient, family, and community strengths are lacking. We report the protocol of the Achieving Blood Pressure Control Together (ACT) study, a randomized controlled trial designed to study the effectiveness of interventions that engage patient, family, and community-level resources to facilitate urban African American hypertensive patients' improved hypertension self-management and subsequent hypertension control. African American patients with uncontrolled hypertension receiving health care in an urban primary care clinic will be randomly assigned to receive 1) an educational intervention led by a community health worker alone, 2) the community health worker intervention plus a patient and family communication activation intervention, or 3) the community health worker intervention plus a problem-solving intervention. All participants enrolled in the study will receive and be trained to use a digital home blood pressure machine. The primary outcome of the randomized controlled trial will be patients' blood pressure control at 12months. Results from the ACT study will provide needed evidence on the effectiveness of comprehensive multi-level interventions to improve urban African American patients' hypertension control. Copyright © 2014 Elsevier Inc. All rights reserved.
Control volume based hydrocephalus research; analysis of human data
NASA Astrophysics Data System (ADS)
Cohen, Benjamin; Wei, Timothy; Voorhees, Abram; Madsen, Joseph; Anor, Tomer
2010-11-01
Hydrocephalus is a neuropathophysiological disorder primarily diagnosed by increased cerebrospinal fluid volume and pressure within the brain. To date, utilization of clinical measurements have been limited to understanding of the relative amplitude and timing of flow, volume and pressure waveforms; qualitative approaches without a clear framework for meaningful quantitative comparison. Pressure volume models and electric circuit analogs enforce volume conservation principles in terms of pressure. Control volume analysis, through the integral mass and momentum conservation equations, ensures that pressure and volume are accounted for using first principles fluid physics. This approach is able to directly incorporate the diverse measurements obtained by clinicians into a simple, direct and robust mechanics based framework. Clinical data obtained for analysis are discussed along with data processing techniques used to extract terms in the conservation equation. Control volume analysis provides a non-invasive, physics-based approach to extracting pressure information from magnetic resonance velocity data that cannot be measured directly by pressure instrumentation.
Zhang, Xingguang; Zhang, Yanqi; Gao, Xiaoxiao; Wu, Jinxiao; Jiao, Xiumin; Zhao, Jing; Lv, Xiaofeng
2014-05-01
To investigate the effect of combination therapy of backward walking training and alpha-lipoic acid (ALA) treatment on the distribution of plantar pressure in patients with diabetic peripheral neuropathy (DPN). This study is a double-blinded, randomized controlled trial. The test group was treated with combination therapy of backward walking exercise and ALA (ALA for 2wk, backward walking exercise for 12wk), and the control group only received ALA treatment. Clinical and laboratory setting. Patients with DPN (N=60) were divided into the test group (n=30) or control group (n=30). Backward walking exercise with ALA treatment for the test group; lipoic acid treatment for the control group. Plantar pressure before and after treatment was tested and analyzed with the flatbed plantar pressure measurement system. After treatment, peak plantar pressure in the forefoot dropped for both the test and control groups; peak plantar pressure for the test group dropped significantly. Peak plantar pressure in the medial foot slightly increased for the test group, suggesting a more even distribution of plantar pressure in the test group after treatment. The combination therapy of ALA and backward walking proved to be more effective than ALA monotherapy. Backward walking also proved to have an ameliorating effect on balance ability and muscle strength of patients with DPN. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Low-cost feedback-controlled syringe pressure pumps for microfluidics applications.
Lake, John R; Heyde, Keith C; Ruder, Warren C
2017-01-01
Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips.
Low-cost feedback-controlled syringe pressure pumps for microfluidics applications
Lake, John R.; Heyde, Keith C.
2017-01-01
Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips. PMID:28369134
Vijayaraghavan, Maya; He, Guozhong; Stoddard, Pamela; Schillinger, Dean
2010-09-01
To determine prevalence of blood pressure control, hypertension, hypertension awareness, and antihypertensive treatment among adults (> 18 years old) with diabetes living in the border region between the United States of America and Mexico, and to explore variation in those variables between all adults on the Mexican side of the border ("Mexicans") and three groups on the U.S. side of the border ("all U.S. adults," "U.S.-born Hispanics," and "Mexican immigrants"). Using data from Phase I (February 2001-October 2002) of the U.S.-Mexico Border Diabetes Prevention and Control Project, a prevalence study of type 2 diabetes and its risk factors, age-adjusted prevalence of hypertension-related variables was calculated for the sample (n = 682) and differences between the border groups were examined through logistic regression. Less than one-third of the sample had controlled blood pressure (< 130/80 mm Hg), almost half had hypertension (≥140/90 mm Hg), and hypertension awareness and treatment were inadequate. After adjusting for demographics, body mass index, and access to health care, there were no differences in blood pressure control, hypertension, hypertension awareness, or treatment between Mexicans and both U.S. adults and Mexican immigrants. However, compared to Mexicans and Mexican immigrants, U.S.-born Hispanics, particularly younger individuals, had the lowest rates of blood pressure control (17.3%) and the highest rates of coexisting hypertension (54.8%). Compared to Mexicans, U.S.-born Hispanics had lower odds of controlled blood pressure (odds ratio [OR] 0.30, 95% confidence interval [CI] 0.09-0.95) and greater odds of hypertension (OR 3.75, 95% CI 1.51-9.29) and hypertension awareness (OR 6.19, 95% CI 1.46-26.15). Co-occurrence of diabetes and hypertension is a major public health problem among U.S.-Mexico border residents. The low rate of blood pressure control among various border groups, especially younger U.S.-born Hispanics, suggests that initiatives should aggressively target blood pressure control.
Naseem, Sajida; Ghazanfar, Haider; Assad, Salman; Ghazanfar, Ali
2016-07-01
To assess the change in systolic and diastolic blood pressure in post-interventional phase through dietary approaches to stop hypertension/salt-restricted diet. This randomised controlled clinical study was conducted from February 2014 to March 2015 at the Armed Forces Institute of Cardiology, Rawalpindi, and Ali Medical Centre, Islamabad, Pakistan, and involved hypertensive patients and matching controls. The control group followed routine diet while the intervention group was given a diet plan containing 1,500mg of sodium providing 2,000 calories. Both groups were advised not to consume sodium-rich foods. Paired sample t-test was applied to determine the change in blood pressure among the groups at two different occasions. Of the 1,492 participants, 710(47.6%) were controls and 782(52.4%) were in the interventional group. Overall, 417(27.9%) participants got their blood pressure checked less than twice in six months, while 409(27.4%) had it done on a regular basis. Moreover, 941(63.1%)) subjects had a family history of high blood pressure and 149(10.0%) participants did not exercise at all. The overall mean age was 53.42±9.302 years. Mean systolic blood pressure and diastolic blood pressure after five weeks was 126.33±3.35 and 84.40±3.04mmHg in the intervention group, and128.41±3.52 and 84.04±2.953mmHg in the control group. Changes in blood pressure between the two groups were minimal but statistically significant (p<0.05). A diet which is restricted in salt, rich in fruits, vegetables, and low-fat dairy foods and reduced saturated and total fat can substantially lower blood pressure. Such a diet offers an additional nutritional approach to the prevention and treatment of hypertension.
Engine control system having pressure-based timing
Willi, Martin L [Dunlap, IL; Fiveland, Scott B [Metamora, IL; Montgomery, David T [Edelstein, IL; Gong, Weidong [Dunlap, IL
2011-10-04
A control system for an engine having a first cylinder and a second cylinder is disclosed having a first engine valve movable to regulate a fluid flow of the first cylinder and a first actuator associated with the first engine valve. The control system also has a second engine valve movable to regulate a fluid flow of the second cylinder and a sensor configured to generate a signal indicative of a pressure within the first cylinder. The control system also has a controller that is in communication with the first actuator and the sensor. The controller is configured to compare the pressure within the first cylinder with a desired pressure and selectively regulate the first actuator to adjust a timing of the first engine valve independently of the timing of the second engine valve based on the comparison.
Distributed Autonomous Control Action Based on Sensor and Mission Fusion
2005-09-01
programmable control algorithm driven by the readings of two pressure switch sensors located on either side of the valve unit. Thus, a micro-controller...and Characterization The process of leak detection and characterization must be accomplished with a set of pressure switch sensors. This sensor...economically supplementing existing widely used pressure switch type sensors which are characterized by prohibitively long inertial lag responses
Hydrostatic pulpal pressure effect upon microleakage.
Roberts, Howard W; Pashley, David H
2012-02-01
To evaluate if hydrostatic pulpal pressure plays a role in reducing microleakage. Uniform Class 5 preparations were accomplished on human molars with one margin on root dentin. Prepared teeth were randomly placed in one of three groups: (1) Hydrostatic pressure simulation at 20 cm pulpal pressure; (2) Hydrostatic pressure simulation but no pressure applied (positive control); and (3) Conventional microleakage method. Specimens were subjected to 24 hours methylene blue dye, sectioned, and microleakage assessed as a function of microleakage length versus entire preparation wall length using a traveling microscope. Hydrostatic pressure specimens demonstrated less gingival wall microleakage than the control groups while no difference was found between occlusal preparation walls.
Godwin, Marshall; Dawes, Martin; Kiss, Alexander; Tobe, Sheldon W; Grant, F Curry; Kaczorowski, Janusz
2011-01-01
Objective To compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard. Design Multi-site cluster randomised controlled trial. Setting Primary care practices in five cities in eastern Canada. Participants 555 patients with systolic hypertension and no serious comorbidities under the care of 88 primary care physicians in 67 practices in the community. Interventions Practices were randomly allocated to either ongoing use of manual office blood pressure (control group) or automated office blood pressure (intervention group) using the BpTRU device. The last routine manual office blood pressure (mm Hg) was obtained from each patient’s medical record before enrolment. Office blood pressure readings were compared before and after enrolment in the intervention and control groups; all readings were also compared with the awake ambulatory blood pressure. Main outcome measure Difference in systolic blood pressure between awake ambulatory blood pressure minus automated office blood pressure and awake ambulatory blood pressure minus manual office blood pressure. Results Cluster randomisation allocated 31 practices (252 patients) to manual office blood pressure and 36 practices (303 patients) to automated office blood pressure measurement. The most recent routine manual office blood pressure (149.5 (SD 10.8)/81.4 (8.3)) was higher than automated office blood pressure (135.6 (17.3)/77.7 (10.9)) (P<0.001). In the control group, routine manual office blood pressure before enrolment (149.9 (10.7)/81.8 (8.5)) was reduced to 141.4 (14.6)/80.2 (9.5) after enrolment (P<0.001/P=0.01), but the reduction in the intervention group from manual office to automated office blood pressure was significantly greater (P<0.001/P=0.02). On the first study visit after enrolment, the estimated mean difference for the intervention group between the awake ambulatory systolic/diastolic blood pressure and automated office blood pressure (−2.3 (95% confidence interval −0.31 to −4.3)/−3.3 (−2.7 to −4.4)) was less (P=0.006/P=0.26) than the difference in the control group between the awake ambulatory blood pressure and the manual office blood pressure (−6.5 (−4.3 to −8.6)/−4.3 (−2.9 to −5.8)). Systolic/diastolic automated office blood pressure showed a stronger (P<0.001) within group correlation (r=0.34/r=0.56) with awake ambulatory blood pressure after enrolment compared with manual office blood pressure versus awake ambulatory blood pressure before enrolment (r=0.10/r= 0.40); the mean difference in r was 0.24 (0.12 to 0.36)/0.16 (0.07 to 0.25)). The between group correlation comparing diastolic automated office blood pressure and awake ambulatory blood pressure (r=0.56) was stronger (P<0.001) than that for manual office blood pressure versus awake ambulatory blood pressure (r=0.30); the mean difference in r was 0.26 (0.09 to 0.41). Digit preference with readings ending in zero was substantially reduced by use of automated office blood pressure. Conclusion In compliant, otherwise healthy, primary care patients with systolic hypertension, introduction of automated office blood pressure into routine primary care significantly reduced the white coat response compared with the ongoing use of manual office blood pressure measurement. The quality and accuracy of automated office blood pressure in relation to the awake ambulatory blood pressure was also significantly better when compared with manual office blood pressure. Trial registration Clinical trials NCT 00214053. PMID:21300709
Rankine cycle condenser pressure control using an energy conversion device bypass valve
Ernst, Timothy C; Nelson, Christopher R; Zigan, James A
2014-04-01
The disclosure provides a waste heat recovery system and method in which pressure in a Rankine cycle (RC) system of the WHR system is regulated by diverting working fluid from entering an inlet of an energy conversion device of the RC system. In the system, an inlet of a controllable bypass valve is fluidly coupled to a working fluid path upstream of an energy conversion device of the RC system, and an outlet of the bypass valve is fluidly coupled to the working fluid path upstream of the condenser of the RC system such that working fluid passing through the bypass valve bypasses the energy conversion device and increases the pressure in a condenser. A controller determines the temperature and pressure of the working fluid and controls the bypass valve to regulate pressure in the condenser.
System and method for bidirectional flow and controlling fluid flow in a conduit
Ortiz, M.G.
1999-03-23
A system for measuring bidirectional flow, including backflow, of fluid in a conduit is disclosed. The system utilizes a structural mechanism to create a pressure differential in the conduit. Pressure sensors are positioned upstream from the mechanism, at the mechanism, and downstream from the mechanism. Data from the pressure sensors are transmitted to a microprocessor or computer, and pressure differential detected between the pressure sensors is then used to calculate the backflow. Control signals may then be generated by the microprocessor or computer to shut off valves located in the conduit, upon the occurrence of backflow, or to control flow, total material dispersed, etc. in the conduit. 3 figs.
Flow compensating pressure regulator
NASA Technical Reports Server (NTRS)
Baehr, E. F. (Inventor)
1978-01-01
An apparatus for regulating pressure of treatment fluid during ophthalmic procedures is described. Flow sensing and pressure regulating diaphragms are used to modulate a flow control valve. The pressure regulating diaphragm is connected to the flow control valve to urge the valve to an open position due to pressure being applied to the diaphragm by bias means such as a spring. The flow sensing diaphragm is mechanically connected to the flow control valve and urges it to an opened position because of the differential pressure on the diaphragm generated by a flow of incoming treatment fluid through an orifice in the diaphragm. A bypass connection with a variable restriction is connected in parallel relationship to the orifice to provide for adjusting the sensitivity of the flow sensing diaphragm. A multiple lever linkage system is utilized between the center of the second diaphragm and the flow control valve to multiply the force applied to the valve by the other diaphragm and reverse the direction of the force.
S-Duct Engine Inlet Flow Control Using SDBD Plasma Streamwise Vortex Generators
NASA Astrophysics Data System (ADS)
Kelley, Christopher; He, Chuan; Corke, Thomas
2009-11-01
The results of a numerical simulation and experiment characterizing the performance of plasma streamwise vortex generators in controlling separation and secondary flow within a serpentine, diffusing duct are presented. A no flow control case is first run to check agreement of location of separation, development of secondary flow, and total pressure recovery between the experiment and numerical results. Upon validation, passive vane-type vortex generators and plasma streamwise vortex generators are implemented to increase total pressure recovery and reduce flow distortion at the aerodynamic interface plane: the exit of the S-duct. Total pressure recovery is found experimentally with a pitot probe rake assembly at the aerodynamic interface plane. Stagnation pressure distortion descriptors are also presented to show the performance increase with plasma streamwise vortex generators in comparison to the baseline no flow control case. These performance parameters show that streamwise plasma vortex generators are an effective alternative to vane-type vortex generators in total pressure recovery and total pressure distortion reduction in S-duct inlets.
Coladonato, Joseph; Smith, Annette; Watson, Nancy; Brown, Anne T; McNichol, Laurie L; Clegg, Amy; Griffin, Tracy; McPhail, Lora; Montgomery, Terry G
2012-10-01
Hospital bedding and gowns influence skin moisture, temperature, friction, and shear, which in turn may affect the development of pressure ulcers. To evaluate the effect of a new silk-like synthetic fabric on the incidence of pressure ulcers in an acute care setting, two consecutive 6-month clinical trials were conducted among 307 consecutively admitted patients in a Medical Renal Unit (August 2008 and March 2010) and in 275 patients admitted to a Surgical Intensive Care Unit (ICU) (September 2009 to March 2010). During the first 8 weeks, all patients used standard hospital bed linens, reusable underpads, and gowns. During the second 8 weeks, all admitted patients used the intervention linens (a silk-like fabric) followed by another 8 weeks of control (standard linen) use. Demographic variables and the prevalence of pressure ulcers on admission were statistically similar for control and intervention groups in both study populations with the exception of gender in the Renal Unit study (13% higher proportion of men in intervention group). Average Braden Scores were also similar and low (<18) in all study patients. Upon admission to the Medical Renal Unit, 21 of 154 patients (13.6%) in the control and 26 of 153 patients (17.0%) in the intervention group had a pressure ulcer. The incidence of new ulcers was 12.3% in the control and 4.6% in the intervention group (P = 0.01); average length of stay was 5.97 days (σ = 4.0) for control and 5.31 days (σ = 3.8) for intervention patients (P = 0.07). In the Surgical ICU group, 18 of 199 patients in the control (9.1%) and four of 76 patients in the intervention group (5.3%) were admitted with a pressure ulcer; the incidence of new pressure ulcers was 7.5 % in the control and 0% in the intervention group (P = 0.01). Average length of stay was 4.5 days and 4.33 days in the control and intervention groups, respectively (P = 0.33). The significant differences between the control and intervention group in the rate of pressure ulcer development suggests that the type of linens used affect pressure ulcer risk and that this silk-like synthetic fabric technology may help reduce the incidence of pressure ulcers in high-risk patients. Controlled clinical studies in other patient populations are warranted.
Remotely Adjustable Hydraulic Pump
NASA Technical Reports Server (NTRS)
Kouns, H. H.; Gardner, L. D.
1987-01-01
Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.
Decreased cardiopulmonary baroreflex sensitivity in Chagas' heart disease.
Consolim-Colombo, F M; Filho, J A; Lopes, H F; Sobrinho, C R; Otto, M E; Riccio, G M; Mady, C; Krieger, E M
2000-12-01
No study has been performed on reflexes originating from receptors in the heart that might be involved in the pathological lesions of Chagas' heart disease. Our study was undertaken to analyze the role of cardiopulmonary reflex on cardiovascular control in Chagas' disease. We studied 14 patients with Chagas' disease without heart failure and 12 healthy matched volunteers. Central venous pressure, arterial blood pressure, heart rate, forearm blood flow, and forearm vascular resistance were recorded during deactivation of cardiopulmonary receptors. By reducing central venous pressure by applying -10 and -15 mm Hg of negative pressure to the lower body, we observed (a) a similar decrease of central venous pressure in both groups; (b) a marked increase in forearm vascular resistance in the control group but a blunted increase in the Chagas' group; and (c) no significant changes in blood pressure and heart rate. To analyze cardiopulmonary and arterial receptors, we applied -40 mm Hg of lower-body negative pressure. As a consequence, (a) central venous pressure decreased similarly in both groups; (b) blood pressure was maintained in the control group, whereas in patients with Chagas' disease, a decrease in systolic and mean arterial pressure occurred; (c) heart rate increased in both groups; and (d) forearm vascular resistance increased significantly and similarly in both groups. Unloading of receptors with low levels of lower-body negative pressure did not increase forearm vascular resistance in patients with Chagas' disease, which suggests that the reflex mediated by cardiopulmonary receptors is impaired in patients with Chagas' disease without heart failure. Overall control of circulation appears to be compromised because patients did not maintain blood pressure under high levels of lower-body negative pressure.
Swift, Damon L.; Earnest, Conrad P.; Katzmarzyk, Peter T.; Rankinen, Tuomo; Blair, Steven N.; Church, Timothy S.
2011-01-01
Objective Abnormally elevated exercise blood pressure is associated with increased risk of cardiovascular disease. Aerobic exercise training has been shown to reduce exercise blood pressure. However, it is unknown if these improvements occur in a dose dependent manner. The purpose of the present study is to determine the effect of different doses of aerobic exercise training on exercise blood pressure in obese postmenopausal women. Methods Participants (n=404) were randomized to one of 4 groups: 4, 8, or 12 kilocalories per kilogram of energy expenditure per week (kcal/kg/week) or the non-exercise control group for 6 months. Exercise blood pressure was obtained during the 50 watts stage of a cycle ergometer maximal exercise test. Results There was a significant reduction in systolic blood pressure at 50 watts in the 4 kcal/kg/week (−10.9 mmHg, p< 0.001), 8 kcal/kg/week (−9.9 mmHg, p= 0.022), and 12 kcal/kg/week (−13.7 mmHg, p<0.001) compared to control (−4.2 mmHg). Only the highest exercise training dose significantly reduced diastolic blood pressure (−4.3 mmHg, p= 0.033) compared to control. Additionally, resting blood pressure was not altered following exercise training (p>0.05) compared to control, and was not associated with changes in exercise systolic (r=0.09, p=0.09) or diastolic (r=0.10, p=0.08) blood pressure. Conclusions Aerobic exercise training reduces exercise blood pressure and may be more modifiable than changes in resting blood pressure. A high dose of aerobic exercise is recommended to successfully reduce both exercise systolic and diastolic blood pressure, and therefore may attenuate the CVD risk associated with abnormally elevated exercise blood pressure. PMID:22547251
NASA Technical Reports Server (NTRS)
Hrabak, R. R.; Levy, D. W.; Finn, P.; Roskam, J.
1981-01-01
The use of pressure differentials in a flight control system was evaluated. The pressure profile around the test surface was determined using two techniques: (1) windtunnel data (actual); and (2) NASA/Langley Single Element Airfoil Computer Program (theoretical). The system designed to evaluate the concept of using pressure differentials is composed of a sensor drive and power amplifiers, actuator, position potentiometer, and a control surface. The characteristics (both desired and actual) of the system and each individual component were analyzed. The desired characteristics of the system as a whole are given. The flight control system developed, the testing procedures and data reduction methods used, and theoretical frequency response analysis are described.
Kerry, Sally M.; Markus, Hugh S.; Khong, Teck K.; Cloud, Geoffrey C.; Tulloch, Jenny; Coster, Denise; Ibison, Judith; Oakeshott, Pippa
2013-01-01
Background: Adequate control of blood pressure reduces the risk of recurrent stroke. We conducted a randomized controlled study to determine whether home blood pressure monitoring with nurse-led telephone support would reduce blood pressure in patients with hypertension and a history of stroke. Methods: We recruited 381 participants (mean age 72 years) from outpatient and inpatient stroke clinics between Mar. 1, 2007, and Aug. 31, 2009. Nearly half (45%, 170) of the participants had some disability due to stroke. Participants were visited at home for a baseline assessment and randomly allocated to home blood pressure monitoring (n = 187) or usual care (n = 194). Those in the intervention group were given a monitor, brief training and telephone support. Participants who had home blood pressure readings consistently over target (target < 130/80 mm Hg) were advised to consult their family physician. The main outcome measure was a fall in systolic blood pressure after 12 months, measured by an independent researcher unaware of group allocation. Results: Despite more patients in the intervention group than in the control group having changes to antihypertensive treatment during the trial period (60.1% [98/163] v. 47.6% [78/164], p = 0.02), the fall in systolic blood pressure from baseline did not differ significantly between the groups (adjusted mean difference 0.3 mm Hg, 95% confidence interval –3.6 to 4.2 mm Hg). Subgroup analysis showed significant interaction with disability due to stroke (p = 0.03 at 6 months) and baseline blood pressure (p = 0.03 at 12 months). Interpretation: Overall, home monitoring did not improve blood pressure control in patients with hypertension and a history of stroke. It was associated with a fall in systolic pressure in patients who had uncontrolled blood pressure at baseline and those without disability due to stroke. Trial registration: ClinicalTrials.gov registration NCT00514800 PMID:23128283
Improving Hypertension Control and Patient Engagement Using Digital Tools.
Milani, Richard V; Lavie, Carl J; Bober, Robert M; Milani, Alexander R; Ventura, Hector O
2017-01-01
Hypertension is present in 30% of the adult US population and is a major contributor to cardiovascular disease. The established office-based approach yields only 50% blood pressure control rates and low levels of patient engagement. Available home technology now provides accurate, reliable data that can be transmitted directly to the electronic medical record. We evaluated blood pressure control in 156 patients with uncontrolled hypertension enrolled into a home-based digital-medicine blood pressure program and compared them with 400 patients (matched to age, sex, body mass index, and blood pressure) in a usual-care group after 90 days. Digital-medicine patients completed questionnaires online, were asked to submit at least one blood pressure reading/week, and received medication management and lifestyle recommendations via a clinical pharmacist and a health coach. Blood pressure units were commercially available that transmitted data directly to the electronic medical record. Digital-medicine patients averaged 4.2 blood pressure readings per week. At 90 days, 71% of digital-medicine vs 31% of usual-care patients had achieved target blood pressure control. Mean decrease in systolic/diastolic blood pressure was 14/5 mm Hg in digital medicine, vs 4/2 mm Hg in usual care (P < .001). Excess sodium consumption decreased from 32% to 8% in the digital-medicine group (P = .004). Mean patient activation increased from 41.9 to 44.1 (P = .008), and the percentage of patients with low patient activation decreased from 15% to 6% (P = .03) in the digital-medicine group. A digital hypertension program is feasible and associated with significant improvement in blood pressure control rates and lifestyle change. Utilization of a virtual health intervention using connected devices improves patient activation and is well accepted by patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Reducing the pressure drag of a D-shaped bluff body using linear feedback control
NASA Astrophysics Data System (ADS)
Dalla Longa, L.; Morgans, A. S.; Dahan, J. A.
2017-12-01
The pressure drag of blunt bluff bodies is highly relevant in many practical applications, including to the aerodynamic drag of road vehicles. This paper presents theory revealing that a mean drag reduction can be achieved by manipulating wake flow fluctuations. A linear feedback control strategy then exploits this idea, targeting attenuation of the spatially integrated base (back face) pressure fluctuations. Large-eddy simulations of the flow over a D-shaped blunt bluff body are used as a test-bed for this control strategy. The flow response to synthetic jet actuation is characterised using system identification, and controller design is via shaping of the frequency response to achieve fluctuation attenuation. The designed controller successfully attenuates integrated base pressure fluctuations, increasing the time-averaged pressure on the body base by 38%. The effect on the flow field is to push the roll-up of vortices further downstream and increase the extent of the recirculation bubble. This control approach uses only body-mounted sensing/actuation and input-output model identification, meaning that it could be applied experimentally.
Bharucha, Jitendra B; Seaman, Linda; Powers, Michele; Kelly, Erica; Seaman, Rodney; Forcier, Lea; McGinnis, Janice; Nodiff, Isabel; Pawlak, Brooke; Snyder, Samantha; Nodiff, Susan; Patel, Rohan; Squitieri, Rafael; Wang, Lansheng
2018-06-08
The purpose of this study was to determine the effectiveness of a novel, noninvasive perfusion enhancement system versus beds with integrated alternating pressure capabilities for the prevention of hospital-acquired sacral region (sacral, coccygeal, and ischium) pressure injuries in a high-risk, acute care patient population. A prospective randomized trial of high-risk inpatients without preexisting sacral region pressure injuries was conducted. The sample comprised 431 randomly enrolled adult patients in a 300-bed tertiary care community teaching hospital. Subjects were randomly allocated to one of 2 groups: control and experimental. Both groups received "standard-of-care" pressure injury prevention measures per hospital policy, and both were placed on alternating pressure beds during their hospital stays. In addition, patients in the experimental group used a noninvasive perfusion enhancement system placed on top of their alternating pressure beds and recovery chairs throughout their hospital stay. Fischer's exact probability test was used to compare group differences, and odds ratio (OR) were calculated for comparing pressure injury rates in the experimental and control groups. Three hundred ninety-nine patients completed the trial; 186 patients were allocated to the experimental group and 213 patients to the control group. Eleven patients in the control group versus 2 in the experimental group developed hospital-acquired sacral region pressure injuries (51.6% vs 1.07%; P = .024). Control patients were 5.04 times more likely to develop hospital-acquired sacral region pressure injuries (OR = 0.1996; 95% CI, 0.0437-0.9125). Patients using a noninvasive perfusion enhancement system developed significantly fewer hospital-acquired sacral pressure injuries than those using an alternating pressure bed without the perfusion enhancement system. These findings suggest that a perfusion enhancement system enhances the success of use of pressure redistributing beds for prevention of hospital-acquired sacral pressure injuries.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
Wang, Ningli; Xie, Xiaobin; Yang, Diya; Xian, Junfang; Li, Yong; Ren, Ruojin; Peng, Xiaoxia; Jonas, Jost B; Weinreb, Robert N
2012-10-01
Low cerebrospinal fluid pressure (CSF-P) may be involved in the pathogenesis of glaucoma. We measured the optic nerve subarachnoid space width (ONSASW) as a surrogate for orbital CSF-P in patients with primary open-angle glaucoma (POAG) with normal and high pressure and a control group. Prospective observational study. The study included 39 patients with POAG; 21 patients had normal pressure (intraocular pressure [IOP] 21 mmHg), and 18 patients had high pressure (IOP >21 mmHg); 21 subjects formed the control group. By using magnetic resonance imaging (MRI) with fat-suppressed fast recovery fast spin echo (FRFSE) T2-weighted sequence, we determined the ONSASW at 3, 9, and 15 mm posterior to the globe. The ONSASW and optic nerve diameter. At all 3 measurement locations of 3, 9, and 15 mm, the ONSASW was significantly (P<0.001, P<0.001, and P = 0.003, respectively) narrower in the normal-pressure group (0.67±0.16, 0.55±0.09, and 0.51±0.12 mm, respectively) than in the high-pressure group (0.93±0.21, 0.70±0.12, and 0.62±0.11 mm, respectively) or the control group (0.87±0.15, 0.67±0.07, and 0.61±0.07 mm, respectively). The high-pressure and control groups did not vary significantly at 3, 9, and 15 mm (P = 0.31, P = 0.39, and P = 0.44, respectively). At all 3 measurement locations, ONSASW was narrower in the normal-pressure group compared with the high-pressure and control groups after adjustment for optic nerve diameter (P<0.01). Correspondingly, the width of the optic nerve subarachnoid space measured at 3, 9, and 15 mm behind the globe, respectively, was significantly (all P<0.05) associated with IOP after adjustment for optic nerve diameter and visual field defect. The narrower orbital optic nerve subarachnoid space in patients with POAG with normal pressure compared with high pressure suggests a lower orbital CSF-P in patients with POAG with normal pressure. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Job strain, blood pressure and response to uncontrollable stress.
Steptoe, A; Cropley, M; Joekes, K
1999-02-01
The association between cardiovascular disease risk and job strain (high-demand, low-control work) may be mediated by heightened physiological stress responsivity. We hypothesized that high levels of job strain lead to increased cardiovascular responses to uncontrollable but not controllable stressors. Associations between job strain and blood pressure reductions after the working day (unwinding) were also assessed. Assessment of cardiovascular responses to standardized behavioral tasks, and ambulatory monitoring of blood pressure and heart rate during a working day and evening. We studied 162 school teachers (60 men, 102 women) selected from a larger survey as experiencing high or low job strain. Blood pressure, heart rate and electrodermal responses to an externally paced (uncontrollable) task and a self-paced (controllable) task were assessed. Blood pressure was monitored using ambulatory apparatus from 0900 to 2230 h on a working day. The groups of subjects with high and low job strain did not differ in demographic factors, body mass or resting cardiovascular activity. Blood pressure reactions to the uncontrollable task were greater in high than low job-strain groups, but responses to the controllable task were not significantly different between groups. Systolic and diastolic blood pressure did not differ between groups over the working day, but decreased to a greater extent in the evening in subjects with low job strain. Job strain is associated with a heightened blood pressure response to uncontrollable but not controllable tasks. The failure of subjects with high job strain to show reduced blood pressure in the evening may be a manifestation of chronic allostatic load.
1998-01-01
equipped with a constant- pressure switch or control: drills; tappers; fastener drivers; horizontal, vertical, and angle grinders with wheels more than...hand-held power tools must be equipped with either a positive “on-off” control switch, a constant pressure switch , or a “lock-on” control: disc sanders...percussion tools with no means of holding accessories securely, must be equipped with a constant- pressure switch that will shut off the power when the
Rodriguez-Roca, Gustavo C; Llisterri-Caro, Jose L; Barrios-Alonso, Vivencio; Alonso-Moreno, Francisco J; Lou-Arnal, Salvador; Prieto-Diaz, Miguel A; Sanchez-Ruiz, Tomas; Dura-Belinchon, Rafael; Santos-Rodriguez, Jose A; Divison-Garrote, Juan A; Gonzalez-Segura, Diego; Banegas-Banegas, Jose R
2009-01-01
To analyse the cardiovascular risk of a broad sample of hypertensive patients and to examine whether there are differences in blood pressure control and associated factors according to the different cardiovascular risk categories. A total of 10,520 patients > or = 18 years old were included (mean age 64.6+/-11.3 years; 53.7% women). In this cohort, 3.3% were average risk, 22.6% low added risk, 22.2% moderate added risk, 33.5% high added risk and 18.4% very high added risk. Blood pressure was controlled in 41.4% (95% CI 40.5-42.4) of the total population, in 91.7% of patients with low added risk, in 19.4% with moderate added risk, in 27.4% with high added risk and in 6.8% with very high added risk. Diabetes was the factor most strongly associated with poor blood pressure control in patients with high to very high added risk (OR=7.2; p<0.0001). More than half of the hypertensive patients treated in primary health care have a high or very high added cardiovascular risk. In these patients, blood pressure control is inadequate and diabetes is associated with a sevenfold increase in the likelihood of poor blood pressure control.
NASA Astrophysics Data System (ADS)
Kassemi, Mohammad; Kartuzova, Olga
2016-03-01
Pressurization and pressure control in cryogenic storage tanks are to a large extent affected by heat and mass transport across the liquid-vapor interface. These mechanisms are, in turn, controlled by the kinetics of the phase change process and the dynamics of the turbulent recirculating flows in the liquid and vapor phases. In this paper, the effects of accommodation coefficient and interfacial turbulence on tank pressurization and pressure control simulations are examined. Comparison between numerical predictions and ground-based measurements in two large liquid hydrogen tank experiments, performed in the K-site facility at NASA Glenn Research Center (GRC) and the Multi-purpose Hydrogen Test Bed (MHTB) facility at NASA Marshall Space Flight Center (MSFC), are used to show the impact of accommodation coefficient and interfacial and vapor phase turbulence on evolution of pressure and temperatures in the cryogenic storage tanks. In particular, the self-pressurization comparisons indicate that: (1) numerical predictions are essentially independent of the magnitude of the accommodation coefficient; and (2) surprisingly, laminar models sometimes provide results that are in better agreement with experimental self-pressurization rates, even in parametric ranges where the bulk flow is deemed fully turbulent. In this light, shortcomings of the present CFD models, especially, numerical treatments of interfacial mass transfer and turbulence, as coupled to the Volume-of-Fluid (VOF) interface capturing scheme, are underscored and discussed.
Multi-bottle, no compressor, mean pressure control system for a Stirling engine
Corey, John A.
1990-01-01
The invention relates to an apparatus for mean pressure control of a Stirling engine without the need for a compressor. The invention includes a multi-tank system in which there is at least one high pressure level tank and one low pressure level tank wherein gas flows through a maximum pressure and supply line from the engine to the high pressure tank when a first valve is opened until the maximum pressure of the engine drops below that of the high pressure tank opening an inlet regulator to permit gas flow from the engine to the low pressure tank. When gas flows toward the engine it flows through the minimum pressure supply line 2 when a second valve is opened from the low pressure tank until the tank reaches the engine's minimum pressure level at which time the outlet regulator opens permitting gas to be supplied from the high pressure tank to the engine. Check valves between the two tanks prevent any backflow of gas from occurring.
Sng, B L; Tan, H S; Sia, A T H
2014-01-01
Hypotension necessitating vasopressor administration occurs commonly during caesarean section under spinal anaesthesia. We developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non-invasive arterial pressure monitoring. A phenylephrine bolus of 50 μg was given at 30-s intervals when systolic blood pressure fell < 90% of baseline; an ephedrine bolus of 4 mg was given instead if systolic pressure fell < 90% of baseline together with a heart rate < 60 beats.min(-1). The control group used manual boluses of either phenylephrine 100 μg or ephedrine 8 mg, administered at 1-min intervals based on the same thresholds for systolic pressure and heart rate. This randomised, controlled, double-blinded trial involved 213 healthy women who underwent elective caesarean delivery under spinal anaesthesia using 11 mg hyperbaric bupivacaine with 15 μg fentanyl and 100 μg morphine. The automated vasopressor group had better systolic pressure control, with 37/106 (34.9%) having any beat-to-beat systolic pressure reading < 80% of baseline compared with 63/107 (58.9%) in the control group (p < 0.001). There was no difference in the incidence of reactive hypertension, defined as systolic pressure > 120% of baseline, with 8/106 (7.5%) in the automated vasopressor group vs 14/107 (13.1%) in the control group, or total dose of vasopressors. The automated vasopressor group had lower median absolute performance error of 8.5% vs control of 9.8% (p = 0.013), and reduced incidence of nausea (1/106 (0.9%) vs 11/107 (10.3%), p = 0.005). Neonatal umbilical cord pH, umbilical lactate and Apgar scores were similar. Hence, our system afforded better control of maternal blood pressure and reduced nausea with no increase in reactive hypertension when compared with manual boluses. © 2013 The Association of Anaesthetists of Great Britain and Ireland.
Manufacturing Diamond Under Very High Pressure
NASA Technical Reports Server (NTRS)
Voronov, Oleg
2007-01-01
A process for manufacturing bulk diamond has been made practical by the invention of the High Pressure and Temperature Apparatus capable of applying the combination of very high temperature and high pressure needed to melt carbon in a sufficiently large volume. The apparatus includes a reaction cell wherein a controlled static pressure as high as 20 GPa and a controlled temperature as high as 5,000 C can be maintained.
A computational analysis of the long-term regulation of arterial pressure
Beard, Daniel A.
2013-01-01
The asserted dominant role of the kidneys in the chronic regulation of blood pressure and in the etiology of hypertension has been debated since the 1970s. At the center of the theory is the observation that the acute relationships between arterial pressure and urine production—the acute pressure-diuresis and pressure-natriuresis curves—physiologically adapt to perturbations in pressure and/or changes in the rate of salt and volume intake. These adaptations, modulated by various interacting neurohumoral mechanisms, result in chronic relationships between water and salt excretion and pressure that are much steeper than the acute relationships. While the view that renal function is the dominant controller of arterial pressure has been supported by computer models of the cardiovascular system known as the “Guyton-Coleman model”, no unambiguous description of a computer model capturing chronic adaptation of acute renal function in blood pressure control has been presented. Here, such a model is developed with the goals of: 1. representing the relevant mechanisms in an identifiable mathematical model; 2. identifying model parameters using appropriate data; 3. validating model predictions in comparison to data; and 4. probing hypotheses regarding the long-term control of arterial pressure and the etiology of primary hypertension. The developed model reveals: long-term control of arterial blood pressure is primarily through the baroreflex arc and the renin-angiotensin system; and arterial stiffening provides a sufficient explanation for the etiology of primary hypertension associated with ageing. Furthermore, the model provides the first consistent explanation of the physiological response to chronic stimulation of the baroreflex. PMID:24555102
Lei, Yun; Jin, Jiu; Ban, Haipeng; Du, Yuzheng
2017-11-12
To observe the effects of acupuncture combined with medication on circadian rhythm of blood pressure in patients with essential hypertension. Sixty-four patients of essential hypertension were randomly divided into an observation group and a control group, 32 cases in each group. All the patients maintained original treatment (taking antihypertensive medication); the patients in the observation group were treated with acupuncture method of " Huoxue Sanfeng , Shugan Jianpi ", once a day, five times per week, for totally 6 weeks (30 times). The circadian rhythm of blood pressure and related dynamic parameters were observed before and after treatment in the two groups. (1) The differences of daytime average systolic blood pressure (dASBP), daytime average diastolic blood pressure (dADBP), nighttime average systolic blood pressure (nASBP) and circadian rhythm of systolic blood pressure before and after treatment were significant in the observation group (all P <0.05); the differences of circadian rhythm of blood pressure and related dynamic parameters before and after treatment were insignificant in the control group (all P >0.05). The nASBP and circadian rhythm of systolic blood pressure in the observation group were significantly different from those in the control group (all P <0.05). (2) After the treatment, the spoon-shaped rate of circadian rhythm of blood pressure in the observation group was higher than that in the control group ( P <0.05). The acupuncture combined with medication could effectively improve the circadian rhythm of blood pressure and related dynamic parameters in patients with essential hypertension.
A computational analysis of the long-term regulation of arterial pressure.
Beard, Daniel A; Pettersen, Klas H; Carlson, Brian E; Omholt, Stig W; Bugenhagen, Scott M
2013-01-01
The asserted dominant role of the kidneys in the chronic regulation of blood pressure and in the etiology of hypertension has been debated since the 1970s. At the center of the theory is the observation that the acute relationships between arterial pressure and urine production-the acute pressure-diuresis and pressure-natriuresis curves-physiologically adapt to perturbations in pressure and/or changes in the rate of salt and volume intake. These adaptations, modulated by various interacting neurohumoral mechanisms, result in chronic relationships between water and salt excretion and pressure that are much steeper than the acute relationships. While the view that renal function is the dominant controller of arterial pressure has been supported by computer models of the cardiovascular system known as the "Guyton-Coleman model", no unambiguous description of a computer model capturing chronic adaptation of acute renal function in blood pressure control has been presented. Here, such a model is developed with the goals of: 1. representing the relevant mechanisms in an identifiable mathematical model; 2. identifying model parameters using appropriate data; 3. validating model predictions in comparison to data; and 4. probing hypotheses regarding the long-term control of arterial pressure and the etiology of primary hypertension. The developed model reveals: long-term control of arterial blood pressure is primarily through the baroreflex arc and the renin-angiotensin system; and arterial stiffening provides a sufficient explanation for the etiology of primary hypertension associated with ageing. Furthermore, the model provides the first consistent explanation of the physiological response to chronic stimulation of the baroreflex.
NASA Technical Reports Server (NTRS)
Sandford, M. C.; Ricketts, R. H.
1983-01-01
A high aspect ratio supercritical wing with oscillating control surfaces is described. The semispan wing model was instrumented with 252 static pressure orifices and 164 in situ dynamic pressure gages for studying the effects of control surface position and sinusoidal motion on steady and unsteady pressures. Results from the present test (the third in a series of tests on this model) were obtained in the Langley Transonic Dynamics Tunnel at Mach numbers of 0.60, 0.78, and 0.86 and are presented in tabular form.
Management of postpartum hemorrhage with free-flow pressure controlled uterine balloon.
Theron, Gerhard B
2018-05-20
The free-flow pressure controlled uterine balloon (Ellavi UBT; Sinapi biomedical, Stellenbosch, South Africa) allows the expulsion of water from the balloon to reduce volume and pressure control by adjusting the height of the supply bag above the patient. The balloon can be filled to a capacity of 750 mL without requiring expansion pressure. The device is affordable for use in lesser resourced countries with a sales price from the factory of approximately US $6. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
D0 Solenoid Upgrade Project: Pressure Ratings for Some Chimney and Control Dewar Componenets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rucinski, R.; /Fermilab
1993-05-25
Pressure rating calculations were done for some of the chimney and control dewar components. This engineering note documents these calculations. The table below summarizes the components looked at, and what pressure rating are. The raw engineering calculations for each of the components is given.
49 CFR 236.554 - Rate of pressure reduction; equalizing reservoir or brake pipe.
Code of Federal Regulations, 2011 CFR
2011-10-01
... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions... pressure or brake-pipe pressure reduction during an automatic brake application shall be at a rate not less...
49 CFR 236.554 - Rate of pressure reduction; equalizing reservoir or brake pipe.
Code of Federal Regulations, 2010 CFR
2010-10-01
... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions... pressure or brake-pipe pressure reduction during an automatic brake application shall be at a rate not less...
A Venturi microregulator array module for distributed pressure control
Chang, Dustin S.; Langelier, Sean M.; Zeitoun, Ramsey I.
2010-01-01
Pressure-driven flow control systems are a critical component in many microfluidic devices. Compartmentalization of this functionality into a stand-alone module possessing a simple interface would allow reduction of the number of pneumatic interconnects required for fluidic control. Ideally, such a module would also be sufficiently compact for implementation in portable platforms. In our current work, we show the feasibility of using a modular array of Venturi pressure microregulators for coordinated droplet manipulation. The arrayed microregulators share a single pressure input and are capable of outputting electronically controlled pressures that can be independently set between ±1.3 kPa. Because the Venturi microregulator operates by thermal perturbation of a choked gas flow, this output range corresponds to a temperature variation between 20 and 95°C. Using the array, we demonstrate loading, splitting, merging, and independent movement of multiple droplets in a valveless microchannel network. PMID:20938490
Tailakh, Ayman K; Evangelista, Lorraine S; Morisky, Donald E; Mentes, Janet C; Pike, Nancy A; Phillips, Linda R
2016-01-01
The aim of this study was to examine the relationship between acculturation, medication adherence, lifestyle behaviors (e.g., physical activity, nutrition, weight control), and blood pressure control among hypertensive Arab Americans. The study utilized a cross-sectional descriptive design. A convenience sample of 126 participants completed questionnaires and had measures of blood pressure, weight, and height. Forty-six participants were hypertensive and were included in the analysis. Only 29.2% of participants reported high medication adherence. High medication adherence was associated with lower diastolic blood pressure, eating a healthy diet, and following lifestyle modifications. Acculturation was significantly associated with physical activity and body mass index. Our study found that acculturated participants were more adherent to medications and physical activity and had better blood pressure control. Further studies are needed to explore how acculturation improves adherence and what factors contribute to better adherence in order to design culturally sensitive interventions. © The Author(s) 2014.
Tailakh, Ayman K.; Evangelista, Lorraine S.; Morisky, Donald E.; Mentes, Janet C.; Pike, Nancy A.; Phillips, Linda R.
2015-01-01
Purpose The aim of this study was to examine the relationship between acculturation, medication adherence, lifestyle behaviors (e.g., physical activity, nutrition, weight control), and blood pressure control among hypertensive Arab Americans. Design The study utilized a cross-sectional descriptive design. A convenience sample of 126 participants completed questionnaires and had measures of blood pressure, weight, and height. Forty-six participants were hypertensive and were included in the analysis. Results Only 29.2% of participants reported high medication adherence. High medication adherence was associated with lower diastolic blood pressure, eating a healthy diet, and following lifestyle modifications. Acculturation was significantly associated with physical activity and body mass index. Conclusion Our study found that acculturated participants were more adherent to medications and physical activity and had better blood pressure control. Further studies are needed to explore how acculturation improves adherence and what factors contribute to better adherence in order to design culturally sensitive interventions. PMID:24848347
Wong, Holly; Kaufman, Jaime; Baylis, Barry; Conly, John M; Hogan, David B; Stelfox, Henry T; Southern, Danielle A; Ghali, William A; Ho, Chester H
2015-09-29
Interface pressure is a key risk factor in the development of pressure ulcers. Visual feedback of continuous interface pressure between the body and support surface could inform clinicians on repositioning strategies and play a key role in an overall strategy for the prevention and management of pressure ulcers. A parallel two-group randomized controlled clinical trial will be conducted to study the effect of continuous pressure imaging on reducing interface pressure and on the incidence of pressure ulcers in vulnerable hospital patients. A total of 678 eligible consenting inpatients at risk of pressure ulcer development in a tertiary acute care institution will be randomly allocated to either having the ForeSite PT™ system with the liquid-crystal display monitor turned on to provide visual feedback to the clinicians while also collecting continuous interface pressure data (intervention group) or to having the ForeSite PT™ system with monitor turned off (that is, not providing visual feedback) but still collecting continuous interface pressure data (control group), in a ratio of 1:1. Continuous interface pressure data will be collected in both groups for 3 days (72 h). Data collection will continue until discharge for a subset of approximately 60 patients. The primary outcome will be the differences in the two groups' interface pressure analysis. Interface pressure readings will be collected through hourly samplings of continuous interface pressure recordings. Secondary outcomes will be the differences between the two groups in pressure-related skin and soft tissue changes in areas at risk of pressure ulcer (obtained at baseline within 24 h of admission) and on the third day of the trial or at discharge and perceptions of the intervention by patients and clinicians (obtained on the third day or at discharge). This will be the first randomized controlled trial to investigate the effect of visual feedback with continuous interface pressure of vulnerable hospital patients across different care settings, and the association between interface pressure and development of pressure-related skin and soft tissue changes. The results could provide important information to guide clinical practice in the prevention and management of pressure ulcers. ClinicalTrials.gov NCT02325388 (date of registration: 24 December 2014).
LH2 tank pressure control by thermodynamic vent system (TVS) at zero gravity
NASA Astrophysics Data System (ADS)
Wang, B.; Huang, Y. H.; Chen, Z. C.; Wu, J. Y.; Li, P.; Sun, P. J.
2017-02-01
Thermodynamic vent system (TVS) is employed for pressure control of propellant tanks at zero gravity. An analytical lumped parameter model is developed to predict pressure variation in an 18.09 m3 liquid hydrogen tank equipped with TVS. Mathematical simulations are carried out assuming tank is filled up to 75% volume (liquid mass equals to 945 kg) and is subjected to heat flux of 0.76 W/m2. Tank pressure controls at 165.5-172.4, 165.5-179.3 and 165.5-182.2 kPa are compared with reference to number of vent cycles, vent duration per cycle and loss of hydrogen. Analysis results indicate that the number of vent cycles significantly decreases from 62 to 21 when tank pressure control increases from 6.9 to 20.4 kPa. Also, duration of vent cycle increases from 63 to 152 and cycle duration decreases from 3920 to 3200 s. Further, the analysis result suggests that LH2 evaporation loss per day decreases from 0.17 to 0.14%. Based on the results of analysis, TVS is found effective in controlling the propellant tank pressure in zero gravity.
Posser, Simone Regina; Callegaro, Carine Cristina; Beltrami-Moreira, Marina; Moreira, Leila Beltrami
2016-08-02
Hypertension is a complex chronic condition characterized by elevated arterial blood pressure. Management of hypertension includes non-pharmacologic strategies, which may include techniques that effectively reduce autonomic sympathetic activity. Respiratory exercises improve autonomic control over cardiovascular system and attenuate muscle metaboreflex. Because of these effects, respiratory exercises may be useful to lower blood pressure in subjects with hypertension. This randomized, double-blind clinical trial will test the efficacy of inspiratory muscle training in reducing blood pressure in adults with essential hypertension. Subjects are randomly allocated to intervention or control groups. Intervention consists of inspiratory muscle training loaded with 40 % of maximum inspiratory pressure, readjusted weekly. Control sham intervention consists of unloaded exercises. Systolic and diastolic blood pressures are co-primary endpoint measures assessed with 24 h ambulatory blood pressure monitoring. Secondary outcome measures include cardiovascular autonomic control, inspiratory muscle metaboreflex, cardiopulmonary capacity, and inspiratory muscle strength and endurance. Previously published work suggests that inspiratory muscle training reduces blood pressure in persons with hypertension, but the effectiveness of this intervention is yet to be established. We propose an adequately sized randomized clinical trial to test this hypothesis rigorously. If an effect is found, this study will allow for the investigation of putative mechanisms to mediate this effect, including autonomic cardiovascular control and metaboreflex. ClinicalTrials.gov NCT02275377 . Registered on 30 September 2014.
NASA Technical Reports Server (NTRS)
Culley, Dennis E.; Bright, Michelle M.; Prahst, Patricia S.; Strazisar, Anthony J.
2003-01-01
Micro-flow control actuation embedded in a stator vane was used to successfully control separation and improve near stall performance in a multistage compressor rig at NASA Glenn. Using specially designed stator vanes configured with internal actuation to deliver pulsating air through slots along the suction surface, a research study was performed to identify performance benefits using this microflow control approach. Pressure profiles and unsteady pressure measurements along the blade surface and at the shroud provided a dynamic look at the compressor during microflow air injection. These pressure measurements lead to a tracking algorithm to identify the onset of separation. The testing included steady air injection at various slot locations along the vane. The research also examined the benefit of pulsed injection and actively controlled air injection along the stator vane. Two types of actuation schemes were studied, including an embedded actuator for on-blade control. Successful application of an online detection and flow control scheme will be discussed. Testing showed dramatic performance benefit for flow reattachment and subsequent improvement in diffusion through the use of pulsed controlled injection. The paper will discuss the experimental setup, the blade configurations, and preliminary CFD results which guided the slot location along the blade. The paper will also show the pressure profiles and unsteady pressure measurements used to track flow control enhancement, and will conclude with the tracking algorithm for adjusting the control.
Senior nurses' control expectations and the development of pressure ulcers.
Maylor, M
The aim of this research was to establish whether the attitudes and expectations of senior nursing staff might adversely affect patient outcomes in the prevention of pressure ulcers. The hypothesis was that nursing locus of control affects clinical outcomes in patients. In particular, it affects departmental prevalence of pressure damage. A population of nurses (n = 439) in an acute and community NHS trust were surveyed to test knowledge, control beliefs and value of pressure ulcer prevention relative to prevalence. The research was designed to provide different data against which to test the hypothesis: first, to assess acceptability of nurses' knowledge of prevention and appropriate use of risk assessment and equipment; second, to calculate a mean departmental pressure ulcer prevalence; and third, to measure locus of control and value, which is the focus of this article. There were strong associations between departmental prevalence of pressure ulcers and attitudes of senior nursing staff. For example, the more that ward sisters believed they could control pressure ulcer prevention, the higher the prevalence of ulcers in their department. The more that sisters believed that they could not control prevalence, the lower the prevalence of ulcers. The study shows that failure to account for beliefs, values and expectations of staff could lead to patient harm. It is suggested that it might be counterproductive to put great effort into developing clinical guidelines and refinement of risk assessment methods. The findings have important implications for nursing, and challenge the assumption that nurse leaders are universally beneficial to patients.
Effectiveness of a medical education intervention to treat hypertension in primary care.
Martínez-Valverde, Silvia; Castro-Ríos, Angélica; Pérez-Cuevas, Ricardo; Klunder-Klunder, Miguel; Salinas-Escudero, Guillermo; Reyes-Morales, Hortensia
2012-04-01
In Mexico, hypertension is among the top five causes for visits to primary care clinics; its complications are among the main causes of emergency and hospital care. The present study reports the effectiveness of a continuing medical education (CME) intervention to improve appropriate care for hypertension, on blood pressure control of hypertensive patients in primary care clinics. A secondary data analysis was carried out using data of hypertensive patients treated by family doctors who participated in the CME intervention. The evaluation was designed as a pre-/post-intervention study with control group in six primary care clinics. The effect of the CME intervention was analysed using multiple logistic regression modelling in which the dependent variable was uncontrolled blood pressure in the post-intervention patient measurement. After the CME intervention, the net reduction of uncontrolled blood pressure between stages in the intervention group was 10.3%. The model results were that being treated by a family doctor who participated in the CME intervention reduced by 53% the probability of lack of control of blood pressure; receiving dietary recommendations reduced 57% the probability of uncontrolled blood pressure. Having uncontrolled blood pressure at the baseline stage increased the probability of lack of control in 166%, and per each unit of increase in body mass index the lack of control increased 7%. CME intervention improved the medical decision-making process to manage hypertension, thus increasing the probability of hypertensive patients to have blood pressure under control. © 2010 Blackwell Publishing Ltd.
Development of a Calibration Rig for a Large Multi-Component Rotor Balance
2000-05-01
valve pressure reducer pressure manifold pressure switch pressure transducer pressure relief valve pressure gage off on control valve pressure switch on...Each of the four manifolds has been equipped with a pressure switch , a pressure transducer, a pressure gage, and a pressure relief valve. If the...valve. A pressure switch is installed between the servo valve and the actuator. This pressure switch is used as a diagnostic indicator by the
Electrokinetic high pressure hydraulic system
Paul, Phillip H.; Rakestraw, David J.; Arnold, Don W.; Hencken, Kenneth R.; Schoeniger, Joseph S.; Neyer, David W.
2001-01-01
An electrokinetic high pressure hydraulic pump for manipulating fluids in capillary-based systems. The pump uses electro-osmotic flow to provide a high pressure hydraulic system, having no moving mechanical parts, for pumping and/or compressing fluids, for providing valve means and means for opening and closing valves, for controlling fluid flow rate, and manipulating fluid flow generally and in capillary-based systems (Microsystems), in particular. The compact nature of the inventive high pressure hydraulic pump provides the ability to construct a micro-scale or capillary-based HPLC system that fulfills the desire for small sample quantity, low solvent consumption, improved efficiency, the ability to run samples in parallel, and field portability. Control of pressure and solvent flow rate is achieved by controlling the voltage applied to an electrokinetic pump.
Electrokinetic high pressure hydraulic system
Paul, Phillip H.; Rakestraw, David J.; Arnold, Don W.; Hencken, Kenneth R.; Schoeniger, Joseph S.; Neyer, David W.
2003-06-03
An electrokinetic high pressure hydraulic pump for manipulating fluids in capillary-based system. The pump uses electro-osmotic flow to provide a high pressure hydraulic system, having no moving mechanical parts, for pumping and/or compressing fluids, for providing valve means and means for opening and closing valves, for controlling fluid flow rate, and manipulating fluid flow generally and in capillary-based systems (microsystems), in particular. The compact nature of the inventive high pressure hydraulic pump provides the ability to construct a micro-scale or capillary-based HPLC system that fulfills the desire for small sample quantity, low solvent consumption, improved efficiency, the ability to run samples in parallel, and field portability. Control of pressure and solvent flow rate is achieved by controlling the voltage applied to an electrokinetic pump.
Control of intrauterine fluid pressure during operative hysteroscopy.
Shirk, G J; Gimpelson, R J
1994-05-01
To evaluate the safety of a commonly used piston pump that controls the infusion pressure of low-viscosity fluids in a continuous-flow hysteroscopic system during operative hysteroscopy. Consecutive patients requiring operative hysteroscopy. Three hospital facilities in the Midwest. Sequential sample of 250 women who underwent operative hysteroscopy. Endometrial ablations, resection of submucosal or pedunculated uterine leiomyomata with or without endometrial ablation, polyp resections, metroplasty, and lysis of synechiae. The most serious complication of operative hysteroscopy is fluid overload due to intravasation into the patient's vascular system. Low-viscosity fluids were infused by the Zimmer Controlled Distention Irrigation System. The instrument uses a closed-feedback loop to monitor cavity pressure and automatically regulates the flow to maintain the set point pressure. It is designed to operate in a pressure range of 0 to 80 mm Hg and at flows in excess of 450 ml/minute. In 250 operative hysteroscopies no fluid complications occurred when intrauterine pressure was maintained below 80 mm Hg. No clinically significant differences in intravasation were seen in any type of operative hysteroscopy. This controlled mechanical pump system with exact intrauterine pressure measurement reduced many technical difficulties associated with low-viscosity media, and created a safe environment for the media's use in operative hysteroscopy.
Robust linear parameter-varying control of blood pressure using vasoactive drugs
NASA Astrophysics Data System (ADS)
Luspay, Tamas; Grigoriadis, Karolos
2015-10-01
Resuscitation of emergency care patients requires fast restoration of blood pressure to a target value to achieve hemodynamic stability and vital organ perfusion. A robust control design methodology is presented in this paper for regulating the blood pressure of hypotensive patients by means of the closed-loop administration of vasoactive drugs. To this end, a dynamic first-order delay model is utilised to describe the vasoactive drug response with varying parameters that represent intra-patient and inter-patient variability. The proposed framework consists of two components: first, an online model parameter estimation is carried out using a multiple-model extended Kalman-filter. Second, the estimated model parameters are used for continuously scheduling a robust linear parameter-varying (LPV) controller. The closed-loop behaviour is characterised by parameter-varying dynamic weights designed to regulate the mean arterial pressure to a target value. Experimental data of blood pressure response of anesthetised pigs to phenylephrine injection are used for validating the LPV blood pressure models. Simulation studies are provided to validate the online model estimation and the LPV blood pressure control using phenylephrine drug injection models representing patients showing sensitive, nominal and insensitive response to the drug.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinogeikin, Stanislav V., E-mail: ssinogeikin@carnegiescience.edu; Smith, Jesse S.; Rod, Eric
The ability to remotely control pressure in diamond anvil cells (DACs) in accurate and consistent manner at room temperature, as well as at cryogenic and elevated temperatures, is crucial for effective and reliable operation of a high-pressure synchrotron facility such as High Pressure Collaborative Access Team (HPCAT). Over the last several years, a considerable effort has been made to develop instrumentation for remote and automated pressure control in DACs during synchrotron experiments. We have designed and implemented an array of modular pneumatic (double-diaphragm), mechanical (gearboxes), and piezoelectric devices and their combinations for controlling pressure and compression/decompression rate at various temperaturemore » conditions from 4 K in cryostats to several thousand Kelvin in laser-heated DACs. Because HPCAT is a user facility and diamond cells for user experiments are typically provided by users, our development effort has been focused on creating different loading mechanisms and frames for a variety of existing and commonly used diamond cells rather than designing specialized or dedicated diamond cells with various drives. In this paper, we review the available instrumentation for remote static and dynamic pressure control in DACs and show some examples of their applications to high pressure research.« less
Cryogenic Pressure Control Modeling for Ellipsoidal Space Tanks
NASA Technical Reports Server (NTRS)
Lopez, Alfredo; Grayson, Gary D.; Chandler, Frank O.; Hastings, Leon J.; Heyadat, Ali
2007-01-01
A computational fluid dynamics (CFD) model is developed to simulate pressure control of an ellipsoidal-shaped liquid hydrogen tank under external heating in normal gravity. Pressure control is provided by an axial jet thermodynamic vent system (TVS) centered within the vessel that injects cooler liquid into the tank, mixing the contents and reducing tank pressure. The two-phase cryogenic tank model considers liquid hydrogen in its own vapor with liquid density varying with temperature only and a fully compressible ullage. The axisymmetric model is developed using a custom version of the commercially available FLOW-31) software. Quantitative model validation is ,provided by engineering checkout tests performed at Marshall Space Flight Center in 1999 in support of the Solar Thermal Upper Stage_ Technology Demonstrator (STUSTD) program. The engineering checkout tests provide cryogenic tank self-pressurization test data at various heat leaks and tank fill levels. The predicted self-pressurization rates, ullage and liquid temperatures at discrete locations within the STUSTD tank are in good agreement with test data. The work presented here advances current CFD modeling capabilities for cryogenic pressure control and helps develop a low cost CFD-based design process for space hardware.
Compressed gas fuel storage system
Wozniak, John J.; Tiller, Dale B.; Wienhold, Paul D.; Hildebrand, Richard J.
2001-01-01
A compressed gas vehicle fuel storage system comprised of a plurality of compressed gas pressure cells supported by shock-absorbing foam positioned within a shape-conforming container. The container is dimensioned relative to the compressed gas pressure cells whereby a radial air gap surrounds each compressed gas pressure cell. The radial air gap allows pressure-induced expansion of the pressure cells without resulting in the application of pressure to adjacent pressure cells or physical pressure to the container. The pressure cells are interconnected by a gas control assembly including a thermally activated pressure relief device, a manual safety shut-off valve, and means for connecting the fuel storage system to a vehicle power source and a refueling adapter. The gas control assembly is enclosed by a protective cover attached to the container. The system is attached to the vehicle with straps to enable the chassis to deform as intended in a high-speed collision.
Hydraulic High Pressure Valve Controller Using the In-Situ Pressure Difference
NASA Technical Reports Server (NTRS)
Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Hall, Jeffery L. (Inventor); Sherrit, Stewart (Inventor); Bao, Xiaoqi (Inventor)
2016-01-01
A hydraulic valve controller that uses an existing pressure differential as some or all of the power source for valve operation. In a high pressure environment, such as downhole in an oil or gas well, the pressure differential between the inside of a pipe and the outside of the pipe may be adequately large to drive a linear slide valve. The valve is operated hydraulically by a piston in a bore. When a higher pressure is applied to one end of the bore and a lower pressure to the other end, the piston moves in response to the pressure differential and drives a valve attached to it. If the pressure differential is too small to drive the piston at a sufficiently high speed, a pump is provided to generate a larger pressure differential to be applied. The apparatus is conveniently constructed using multiport valves, which can be rotary valves.
Zhao, Bowen; Zhang, Hongwei; Xu, Qiang; Ge, Quanhu; Li, Bolong; Peng, Xinyu; Wu, Xiangwei
2017-05-01
To investigate the effects of long time different negative pressures on osteogenic diffe-rentiation of rabbit bone mesenchymal stem cells (BMSCs). The rabbit BMSCs were isolated and cultured by density gradient centrifugation. Flow cytometry was used to analyze expression of surface markers. The third passage cells cultured under condition of osteogenic induction and under different negative pressure of 0 mm Hg (control group), 75 mm Hg (low negative pressure group), and 150 mm Hg (high negative pressure group) (1 mm Hg=0.133 kPa), and the negative pressure time was 30 min/h. Cell growth was observed under phase contrast microscopy, and the growth curve was drawn; alkaline phosphatase (ALP) activity was detected by ELISA after induced for 3, 7, and 14 days. The mRNA and protein expressions of collagen type I (COL-I) and osteocalcin (OC) in BMSCs were analyzed by real-time fluorescence quantitative PCR and Western blot. The cultured cells were identified as BMSCs by flow cytometry. The third passage BMSCs exhibited typical long shuttle and irregular shape. Cell proliferation was inhibited with the increase of negative pressure. After induced for 4 days, the cell number of high negative pressure group was significantly less than that in control group and low negative pressure group ( P <0.05), but there was no significant difference between the low negative pressure group and the control group ( P >0.05); at 5-7 days, the cell number showed significant difference between 3 groups ( P <0.05). The greater the negative pressure was, the greater the inhibition of cell proliferation was. There was no significant difference in ALP activity between groups at 3 days after induction ( P >0.05); the ALP activity showed significant difference ( P <0.05) between the high negative pressure group and the control group at 7 days after induction; and significant difference was found in the ALP activity between 3 groups at 14 days after induction ( P <0.05). The greater the negative pressure was, the higher the ALP activity was. Real-time fluorescence quantitative PCR and Western blot detection showed that the mRNA and protein expressions of COL-I and OC protein were significantly higher in low negative pressure group and high negative pressure group than control group ( P <0.05), and in the high negative pressure group than the low negative pressure group ( P <0.05). With the increase of the negative pressure, the osteogenic differentiation ability of BMSCs increases gradually, but the cell proliferation is inhibited.
Low-g fluid mixing - Further results from the Tank Pressure Control Experiment
NASA Technical Reports Server (NTRS)
Bentz, M. D.; Knoll, R. H.; Hasan, M. M.; Lin, C. S.
1993-01-01
The Tank Pressure Control Experiment (TPCE) made its first space flight on STS-43 in 1991. Its objective was to test the effectiveness of low-energy axial jet mixing at controlling pressures in low gravity. The experiment used refrigerant 113 at near-saturation conditions, at an 83 percent fill level, to simulate the fluid dynamics and thermodynamics of cryogenic fluids in future space applications. Results from this flight were reported previously. TPCE was again flown in space on STS-52 in 1992, this time primarily to study boiling and related thermal phenomena which will be reported elsewhere. However additional mixing and pressure control data were obtained from the reflight that supplement the data from the first flight.
Measurement and Control of the Variability of Scanning Pressure Transducer Measurements
NASA Technical Reports Server (NTRS)
Kuhl, David D.; Everhart, Joel L.; Hallissy, James B.
2003-01-01
This paper describes the new wall pressure measurement system and data-quality monitoring software installed at 14x22 Ft subsonic tunnel at the NASA Langley Research Center. The monitoring software was developed to enable measurement and control of the variability of the reference pressures and approximately 400 tunnel wall pressure measurements. Variability of the system, based upon data acquired over a year of wind tunnel tests and calibrations, is presented. The level of variation of the wall pressure measurements is shown to be predictable.
Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.
1990-01-01
Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.
Guelrud, M; Mendoza, S; Vicent, S; Gomez, M; Villalta, B
1983-02-01
To determine the significance of manometric pressure, measurements of the sphincter of Oddi in a control group and in patients with cholelithiasis with common duct stones with and without recurrent pancreatitis were studied. Sphincter of Oddi pressure was recorded continuously and by station pull-through by a triple lumen catheter. The basal sphincter of Oddi pressure, the mean pressure gradient between common duct and duodenum, and the sphincter of Oddi wave amplitude were measured. There was no significant difference between control subjects and patients with gallstones and common duct stones. In patients with common duct stones and recurrent pancreatitis the basal sphincter of Oddi pressure, the pressure gradient between common duct and duodenum, and the wave amplitude were significantly increased over control patients. These studies suggest that abnormalities in the sphincter of Oddi motor function are more common in patients with common duct stones with recurrent pancreatitis than in similar patients without pancreatitis.
Delgado, Francisco José; Delgado, Jonathan; González-Crespo, José; Cava, Ramón; Ramírez, Rosario
2013-12-01
The effect of high-pressure treatment (400 or 600 MPa for 7 min) on microbiology, proteolysis, texture and sensory parameters was investigated in a mature raw goat milk cheese. At day 60 of analysis, Mesophilic aerobic, Enterobacteriaceae, lactic acid bacteria and Listeria spp. were inactivated after high-pressure treatment at 400 or 600 MPa. At day 90, mesophilic aerobic, lactic acid bacteria and Micrococacceae counts were significantly lower in high-pressure-treated cheeses than in control ones. In general, nitrogen fractions were significantly modified after high-pressure treatment on day 60 at 600 MPa compared with control cheeses, but this effect was not found in cheeses after 30 days of storage (day 90). On the other hand, high-pressure treatment caused a significant increase of some texture parameters. However, sensory analysis showed that neither trained panellists nor consumers found significant differences between control and high-pressure-treated cheeses.
Supercritical fluid molecular spray film deposition and powder formation
Smith, Richard D.
1986-01-01
Solid films are deposited, or fine powders formed, by dissolving a solid material into a supercritical fluid solution at an elevated pressure and then rapidly expanding the solution through a short orifice into a region of relatively low pressure. This produces a molecular spray which is directed against a substrate to deposit a solid thin film thereon, or discharged into a collection chamber to collect a fine powder. Upon expansion and supersonic interaction with background gases in the low pressure region, any clusters of solvent are broken up and the solvent is vaporized and pumped away. Solute concentration in the solution is varied primarily by varying solution pressure to determine, together with flow rate, the rate of deposition and to control in part whether a film or powder is produced and the granularity of each. Solvent clustering and solute nucleation are controlled by manipulating the rate of expansion of the solution and the pressure of the lower pressure region. Solution and low pressure region temperatures are also controlled.
Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.
2015-01-01
An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.
Ganni, Venkatarao
2008-08-12
A unique process cycle and apparatus design separates the consumer (cryogenic) load return flow from most of the recycle return flow of a refrigerator and/or liquefier process cycle. The refrigerator and/or liquefier process recycle return flow is recompressed by a multi-stage compressor set and the consumer load return flow is recompressed by an independent consumer load compressor set that maintains a desirable constant suction pressure using a consumer load bypass control valve and the consumer load return pressure control valve that controls the consumer load compressor's suction pressure. The discharge pressure of this consumer load compressor is thereby allowed to float at the intermediate pressure in between the first and second stage recycle compressor sets. Utilizing the unique gas management valve regulation, the unique process cycle and apparatus design in which the consumer load return flow is separate from the recycle return flow, the pressure ratios of each recycle compressor stage and all main pressures associated with the recycle return flow are allowed to vary naturally, thus providing a naturally regulated and balanced floating pressure process cycle that maintains optimal efficiency at design and off-design process cycle capacity and conditions automatically.
Ganni, Venkatarao
2007-10-09
A unique process cycle and apparatus design separates the consumer (cryogenic) load return flow from most of the recycle return flow of a refrigerator and/or liquefier process cycle. The refrigerator and/or liquefier process recycle return flow is recompressed by a multi-stage compressor set and the consumer load return flow is recompressed by an independent consumer load compressor set that maintains a desirable constant suction pressure using a consumer load bypass control valve and the consumer load return pressure control valve that controls the consumer load compressor's suction pressure. The discharge pressure of this consumer load compressor is thereby allowed to float at the intermediate pressure in between the first and second stage recycle compressor sets. Utilizing the unique gas management valve regulation, the unique process cycle and apparatus design in which the consumer load return flow is separate from the recycle return flow, the pressure ratios of each recycle compressor stage and all main pressures associated with the recycle return flow are allowed to vary naturally, thus providing a naturally regulated and balanced floating pressure process cycle that maintains optimal efficiency at design and off-design process cycle capacity and conditions automatically.
Optimization and testing of solid thin film lubrication deposition processes
NASA Astrophysics Data System (ADS)
Danyluk, Michael J.
A novel method for testing solid thin films in rolling contact fatigue (RCF) under ultra-high vacuum (UHV) and high rotational speeds (130 Hz) is presented in this thesis. The UHV-RCF platform is used to quantify the adhesion and lubrication aspects of two thin film coatings deposited on ball-bearings using a physical vapor deposition ion plating process. Plasma properties during ion plating were measured using a Langmuir probe and there is a connection between ion flux, film stress, film adhesion, process voltage, pressure, and RCF life. The UHV-RCF platform and vacuum chamber were constructed using off-the-shelf components and 88 RCF tests in high vacuum have been completed. Maximum RCF life was achieved by maintaining an ion flux between 10 13 to 1015 (cm-2 s-1) with a process voltage and pressure near 1.5 kV and 15 mTorr. Two controller schemes were investigated to maintain optimal plasma conditions for maximum RCF life: PID and LQR. Pressure disturbances to the plasma have a detrimental effect on RCF life. Control algorithms that mitigate pressure and voltage disturbances already exist. However, feedback from the plasma to detect disturbances has not been explored related to deposition processes in the thin-film science literature. Manometer based pressure monitoring systems have a 1 to 2 second delay time and are too slow to detect common pressure bursts during the deposition process. Plasma diagnostic feedback is much faster, of the order of 0.1 second. Plasma total-current feedback was used successfully to detect a typical pressure disturbance associated with the ion plating process. Plasma current is related to ion density and process pressure. A real-time control application was used to detect the pressure disturbance by monitoring plasma-total current and converting it to feedback-input to a pressure control system. Pressure overshoot was eliminated using a nominal PID controller with feedback from a plasma-current diagnostic measurement tool.
NASA Technical Reports Server (NTRS)
Williams, David E.
2008-01-01
The International Space Station (ISS) Pressurized Mating Adapters (PMAs) Environmental Control and Life Support (ECLS) System is comprised of three subsystems: Atmosphere Control and Supply (ACS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). PMAs 1 and 2 flew to ISS on Flight 2A and Pressurized Mating Adapter (PMA) 3 flew to ISS on Flight 3A. This paper provides a summary of the PMAs ECLS design and a detailed discussion of the ISS ECLS Acceptance Testing methodologies utilized for the PMAs.
Economics of Team-based Care in Controlling Blood Pressure: A Community Guide Systematic Review
Jacob, Verughese; Chattopadhyay, Sajal K.; Thota, Anilkrishna B.; Proia, Krista K.; Njie, Gibril; Hopkins, David P.; Finnie, Ramona K.C.; Pronk, Nicolaas P.; Kottke, Thomas E.
2015-01-01
Context High blood pressure is an important risk factor for cardiovascular disease (CVD) and stroke, the leading cause of death in the U.S. and a substantial national burden through lost productivity and medical care. A recent Community Guide systematic review found strong evidence of effectiveness of team-based care in improving blood pressure control. The objective of the present review was to determine from the economic literature whether team-based care for blood pressure control is cost-beneficial and/or cost-effective. Evidence acquisition Electronic databases of papers published January 1980 – May 2012 were searched to find economic evaluations of team-based care interventions to improve blood pressure outcomes, yielding 31 studies for inclusion. Evidence synthesis In analyses conducted in 2012, intervention cost, healthcare cost averted, benefit-to-cost ratios, and cost-effectiveness were abstracted from the studies. The quality of estimates for intervention and healthcare cost from each study were assessed using three elements: intervention focus on blood pressure control; incremental estimates in the intervention group relative to a control group; and inclusion of major cost-driving elements in estimates. Intervention cost per unit reduction in systolic blood pressure was converted to lifetime intervention cost per quality-adjusted life-year (QALY) saved using algorithms from published trials. Conclusion Team-based care to improve blood pressure control is cost-effective based on evidence that 26 of 28 estimates of $/QALY gained from 10 studies were below a conservative threshold of $50,000. This finding is salient to recent health care reforms in the U.S. and coordinated patient-centered care through formation of Accountable Care Organizations (ACOs). PMID:26477804
Special report: Occlusive cuff controller
NASA Technical Reports Server (NTRS)
Baker, J. T.
1975-01-01
A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.
Stability analysis of coupled torsional vibration and pressure in oilwell drillstring system
NASA Astrophysics Data System (ADS)
Toumi, S.; Beji, L.; Mlayeh, R.; Abichou, A.
2018-01-01
To address security issues in oilwell drillstring system, the drilling operation handling which is in generally not autonomous but ensured by an operator may be drill bit destructive or fatal for the machine. To control of stick-slip phenomenon, the drillstring control at the right speed taking only the drillstring vibration is not sufficient as the mud dynamics and the pressure change around the drill pipes cannot be neglected. A coupled torsional vibration and pressure model is presented, and the well-posedness problem is addressed. As a Partial Differential Equation-Ordinary Differential Equation (PDE-ODE) coupled system, and in order to maintain a non destructive downhole pressure, we investigate the control stability with and without the damping term in the wave PDE. In terms of, the torsional variable, the downhole pressure, and the annulus pressure, the coupled system equilibrium is shown to be exponentially stable.
Analysis of pressure losses in the diffuser of a control valve
NASA Astrophysics Data System (ADS)
Turecký, Petr; Mrózek, Lukáš; Tajč, Ladislav; Kolovratník, Michal
The pressure loss in the diffuser of a control valve is evaluated by using CFD computations. Pressure ratios and lifts of a cone for the recommended flow characteristics of an experimental turbine are considered. The pressure loss in a valve is compared with the pressure loss in a nozzle, i.e. the embodiment of the valve without a cone. Computations are carried out for the same mass flow. Velocity profiles are evaluated in both versions of computations. Comparison of computed pressure losses, with the loss evaluated by using relations for diffusers with the ideal velocity conditions in the input cross-section, is carried out.
NASA Technical Reports Server (NTRS)
Mcfadden, J. J.; Dezelick, R. A.; Barrows, R. R.
1983-01-01
Test results from a high pressure electronically controlled fuel injection system are compared with a commercial mechanical injection system on a single cylinder, diesel test engine using an inlet boost pressure of 2.6:1. The electronic fuel injection system achieved high pressure by means of a fluid intensifier with peak injection pressures of 47 to 69 MPa. Reduced exhaust emissions were demonstrated with an increasing rate of injection followed by a fast cutoff of injection. The reduction in emissions is more responsive to the rate of injection and injection timing than to high peak injection pressure.
Allergic rhinitis and arterial blood pressure: a population-based study.
Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S
2018-05-01
To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.
Fan, Lin-bo; Blumenthal, James A.; Hinderliter, Alan L.; Sherwood, Andrew
2013-01-01
Objectives Blunted nighttime blood pressure dipping is an established cardiovascular risk factor. This study examined the effect of job strain on nighttime blood pressure dipping among men and women with high blood pressure. Methods The sample consisted of 122 blue collar and white collar workers (men=72, women=50). Job psychological demands, job control and social support were measured by the Job Content Questionnaire. Job strain was assessed by the ratio of job demands/job control. Nighttime blood pressure dipping was evaluated from 24-hour ambulatory blood pressure monitoring performed on three workdays. Results Men with high job strain had a 5.4 mm Hg higher sleep systolic blood pressure (P=0.03) and 3.5 mm Hg higher sleep pulse pressure (P=0.02) compared to men with low job strain. Men with high job strain had a smaller fall in systolic blood pressure and pulse pressure from awake to sleep than those with low job strain (P<0.05). Hierarchical analyses showed that job strain was an independent determinant of systolic blood pressure dipping (P=0.03) among men after adjusting for ethnicity, body mass index, anxiety and depression symptoms, current smoking status, and alcohol consumption. Further exploratory analyses indicated that job control was the salient component of job strain associated with blood pressure dipping (p=.03). Conclusions High job strain is associated with a blunting of the normal diurnal variation in blood pressure and pulse pressure, which may contribute to the relationship between job strain and cardiovascular disease. PMID:22460541
AUTOMATIC CALIBRATING SYSTEM FOR PRESSURE TRANSDUCERS
Amonette, E.L.; Rodgers, G.W.
1958-01-01
An automatic system for calibrating a number of pressure transducers is described. The disclosed embodiment of the invention uses a mercurial manometer to measure the air pressure applied to the transducer. A servo system follows the top of the mercury column as the pressure is changed and operates an analog- to-digital converter This converter furnishes electrical pulses, each representing an increment of pressure change, to a reversible counterThe transducer furnishes a signal at each calibration point, causing an electric typewriter and a card-punch machine to record the pressure at the instant as indicated by the counter. Another counter keeps track of the calibration points so that a number identifying each point is recorded with the corresponding pressure. A special relay control system controls the pressure trend and programs the sequential calibration of several transducers.
Feedback Regulation of Intracellular Hydrostatic Pressure in Surface Cells of the Lens
Gao, Junyuan; Sun, Xiurong; White, Thomas W.; Delamere, Nicholas A.; Mathias, Richard T.
2015-01-01
In wild-type lenses from various species, an intracellular hydrostatic pressure gradient goes from ∼340 mmHg in central fiber cells to 0 mmHg in surface cells. This gradient drives a center-to-surface flow of intracellular fluid. In lenses in which gap-junction coupling is increased, the central pressure is lower, whereas if gap-junction coupling is reduced, the central pressure is higher but surface pressure is always zero. Recently, we found that surface cell pressure was elevated in PTEN null lenses. This suggested disruption of a feedback control system that normally maintained zero surface cell pressure. Our purpose in this study was to investigate and characterize this feedback control system. We measured intracellular hydrostatic pressures in mouse lenses using a microelectrode/manometer-based system. We found that all feedback went through transport by the Na/K ATPase, which adjusted surface cell osmolarity such that pressure was maintained at zero. We traced the regulation of Na/K ATPase activity back to either TRPV4, which sensed positive pressure and stimulated activity, or TRPV1, which sensed negative pressure and inhibited activity. The inhibitory effect of TRPV1 on Na/K pumps was shown to signal through activation of the PI3K/AKT axis. The stimulatory effect of TRPV4 was shown in previous studies to go through a different signal transduction path. Thus, there is a local two-legged feedback control system for pressure in lens surface cells. The surface pressure provides a pedestal on which the pressure gradient sits, so surface pressure determines the absolute value of pressure at each radial location. We speculate that the absolute value of intracellular pressure may set the radial gradient in the refractive index, which is essential for visual acuity. PMID:26536260
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
Pneumatic pressure wave generator provides economical, simple testing of pressure transducers
NASA Technical Reports Server (NTRS)
Gaal, A. E.; Weldon, T. P.
1967-01-01
Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.
Tobe, Sheldon W; Pylypchuk, George; Wentworth, Joan; Kiss, Alexander; Szalai, John Paul; Perkins, Nancy; Hartman, Susan; Ironstand, Laurie; Hoppe, Jacqueline
2006-04-25
First Nations people with diabetes mellitus and hypertension are at greater risk of renal and cardiovascular complications than are non-native patients because of barriers to health care services. We conducted this randomized controlled trial to assess whether a community-based treatment strategy implemented by home care nurses would be effective in controlling hypertension in First Nations people with existing hypertension and type 2 diabetes. We compared 2 community-based strategies for controlling hypertension in First Nations people with existing hypertension and diabetes. In the intervention group, a home care nurse followed a predefined treatment algorithm of pharmacologic antihypertensive therapy. In the control group, treatment decisions were made by each subject's primary care physician. The primary outcome measure was the difference between the 2 groups in the change in systolic blood pressure after 12 months. Secondary outcome measures were the change in diastolic blood pressure over time, the change in urine albumin status and the incidence of adverse events. Both groups experienced a significant reduction in systolic blood pressure by the final visit (by 24.0 [standard deviation (SD) 13.5] mm Hg in the intervention group and by 17.0 [SD 18.6] mm Hg in the control group); p < 0.001 in each case). However, the difference between the 2 groups in this change was not significant. Patients in the intervention group had a larger decrease in diastolic blood pressure over time than did those in the control group (by 11.6 [SD 10.6] mm Hg v. 6.8 [SD 11.1] mm Hg respectively; p = 0.05). The groups did not differ significantly in terms of changes in urine albumin excretion or incidence of adverse events. High rates of blood pressure control in the community were achieved in both groups in the DREAM 3 study. The addition of a home care nurse to implement a treatment strategy for blood pressure control was more effective in lowering diastolic than systolic blood pressure compared with home care visits for blood pressure monitoring alone and follow-up treatment by a family physician.
Masse, Marie-Hélène; Richard, Marie Anne; D'Aragon, Frédérick; St-Arnaud, Charles; Mayette, Michael; Adhikari, Neill K J; Fraser, William; Carpentier, André; Palanchuck, Steven; Gauthier, David; Lanthier, Luc; Touchette, Matthieu; Lamontagne, Albert; Chénard, Jean; Mehta, Sangeeta; Sansoucy, Yanick; Croteau, Etienne; Lepage, Martin; Lamontagne, François
2018-04-06
Mechanisms underlying sepsis-associated encephalopathy remain unclear, but reduced cerebral blood flow, alone or in conjunction with altered autoregulation, is reported as a potential contributor. We compared cerebral blood flow of control subjects and vasopressor-dependent septic patients. Randomized crossover study. MRI with arterial spin labeling. Ten sedated septic patients on mechanical ventilation (four with controlled chronic hypertension) and 12 control subjects (six with controlled chronic hypertension) were enrolled. Mean ± SD ages were 61.4 ± 10.2 and 44.2 ± 12.8 years, respectively (p = 0.003). Mean Acute Physiology and Chronic Health Evaluation II score of septic patients at ICU admission was 27.7 ± 6.6. To assess the potential confounding effects of sedation and mean arterial pressure, we measured cerebral blood flow with and without sedation with propofol in control subjects and at a target mean arterial pressure of 65 mm Hg and greater than or equal to 75 mm Hg in septic patients. The sequence of sedation versus no sedation and mean arterial pressure targets were randomized. In septic patients, cerebral blood flow measured at a mean arterial pressure target of 65 mm Hg (40.4 ± 10.9 mL/100 g/min) was not different from cerebral blood flow measured at a mean arterial pressure target of greater than or equal to 75 mm Hg (41.3 ± 9.8 mL/100 g/min; p = 0.65). In control subjects, we observed no difference in cerebral blood flow measured without and with sedation (24.8 ± 4.2 vs 24.9 ± 5.9 mL/100 g/min; p = 0.93). We found no interaction between chronic hypertension and the effect of sedation or mean arterial pressure targets. Cerebral blood flow measured in sedated septic patients (mean arterial pressure target 65 mm Hg) was 62% higher than in sedated control subjects (p = 0.001). In septic patients, cerebral blood flow was higher than in sedated control subjects and did not vary with mean arterial pressure targets. Further research is required to understand the clinical significance of cerebral hyperperfusion in septic patients on vasopressors and to reassess the neurologic effects of current mean arterial pressure targets in sepsis.
Cavitation-based hydro-fracturing simulator
Wang, Jy-An John; Wang, Hong; Ren, Fei; Cox, Thomas S.
2016-11-22
An apparatus 300 for simulating a pulsed pressure induced cavitation technique (PPCT) from a pressurized working fluid (F) provides laboratory research and development for enhanced geothermal systems (EGS), oil, and gas wells. A pump 304 is configured to deliver a pressurized working fluid (F) to a control valve 306, which produces a pulsed pressure wave in a test chamber 308. The pulsed pressure wave parameters are defined by the pump 304 pressure and control valve 306 cycle rate. When a working fluid (F) and a rock specimen 312 are included in the apparatus, the pulsed pressure wave causes cavitation to occur at the surface of the specimen 312, thus initiating an extensive network of fracturing surfaces and micro fissures, which are examined by researchers.
Tank depletion flow controller
Georgeson, Melvin A.
1976-10-26
A flow control system includes two bubbler tubes installed at different levels within a tank containing such as radioactive liquid. As the tank is depleted, a differential pressure transmitter monitors pressure differences imparted by the two bubbler tubes at a remote, shielded location during uniform time intervals. At the end of each uniform interval, balance pots containing a dense liquid are valved together to equalize the pressures. The resulting sawtooth-shaped signal generated by the differential pressure transmitter is compared with a second sawtooth signal representing the desired flow rate during each time interval. Variations in the two signals are employed by a control instrument to regulate flow rate.
Level indicator for pressure vessels
Not Available
1982-04-28
A liquid-level monitor for tracking the level of a coal slurry in a high-pressure vessel including a toroidal-shaped float with magnetically permeable bands thereon disposed within the vessel, two pairs of magnetic-field generators and detectors disposed outside the vessel adjacent the top and bottom thereof and magnetically coupled to the magnetically permeable bands on the float, and signal-processing circuitry for combining signals from the top and bottom detectors for generating a monotonically increasing analog control signal which is a function of liquid level. The control signal may be utilized to operate high-pressure control valves associated with processes in which the high-pressure vessel is used.
High pressure liquid level monitor
Bean, Vern E.; Long, Frederick G.
1984-01-01
A liquid level monitor for tracking the level of a coal slurry in a high-pressure vessel including a toroidal-shaped float with magnetically permeable bands thereon disposed within the vessel, two pairs of magnetic field generators and detectors disposed outside the vessel adjacent the top and bottom thereof and magnetically coupled to the magnetically permeable bands on the float, and signal processing circuitry for combining signals from the top and bottom detectors for generating a monotonically increasing analog control signal which is a function of liquid level. The control signal may be utilized to operate high-pressure control valves associated with processes in which the high-pressure vessel is used.
Pressurized reactor system and a method of operating the same
Isaksson, J.M.
1996-06-18
A method and apparatus are provided for operating a pressurized reactor system in order to precisely control the temperature within a pressure vessel in order to minimize condensation of corrosive materials from gases on the surfaces of the pressure vessel or contained circulating fluidized bed reactor, and to prevent the temperature of the components from reaching a detrimentally high level, while at the same time allowing quick heating of the pressure vessel interior volume during start-up. Super-atmospheric pressure gas is introduced from the first conduit into the fluidized bed reactor and heat derived reactions such as combustion and gasification are maintained in the reactor. Gas is exhausted from the reactor and pressure vessel through a second conduit. Gas is circulated from one part of the inside volume to another to control the temperature of the inside volume, such as by passing the gas through an exterior conduit which has a heat exchanger, control valve, blower and compressor associated therewith, or by causing natural convection flow of circulating gas within one or more generally vertically extending gas passages entirely within the pressure vessel (and containing heat exchangers, flow rate control valves, or the like therein). Preferably, inert gas is provided as a circulating gas, and the inert gas may also be used in emergency shut-down situations. In emergency shut-down reaction gas being supplied to the reactor is cut off, while inert gas from the interior gas volume of the pressure vessel is introduced into the reactor. 2 figs.
Pressurized reactor system and a method of operating the same
Isaksson, Juhani M.
1996-01-01
A method and apparatus are provided for operating a pressurized reactor system in order to precisely control the temperature within a pressure vessel in order to minimize condensation of corrosive materials from gases on the surfaces of the pressure vessel or contained circulating fluidized bed reactor, and to prevent the temperature of the components from reaching a detrimentally high level, while at the same time allowing quick heating of the pressure vessel interior volume during start-up. Superatmospheric pressure gas is introduced from the first conduit into the fluidized bed reactor and heat derived reactions such as combustion and gassification are maintained in the reactor. Gas is exhausted from the reactor and pressure vessel through a second conduit. Gas is circulated from one part of the inside volume to another to control the temperature of the inside volume, such as by passing the gas through an exterior conduit which has a heat exchanger, control valve, blower and compressor associated therewith, or by causing natural convection flow of circulating gas within one or more generally vertically extending gas passages entirely within the pressure vessel (and containing heat exchangers, flow rate control valves, or the like therein). Preferably, inert gas is provided as a circulating gas, and the inert gas may also be used in emergency shut-down situations. In emergency shut-down reaction gas being supplied to the reactor is cut off, while inert gas from the interior gas volume of the pressure vessel is introduced into the reactor.
NASA Technical Reports Server (NTRS)
Cox, Matthew C.; Anilkumar, Amrutur V.; Grugel, RIchard N.; Lee, Chun P.
2008-01-01
Directional solidification experiments were performed, using succinonitrile saturated with nitrogen gas, to examine the effects of in-situ processing pressure changes on the formation growth, and evolution of an isolated, cylindrical gaseous pore. A novel solidification facility, capable of processing thin cylindrical samples (I.D. < 1.0 mm), under controlled pressure conditions, was used for the experiments. A new experimental method for growing the isolated pore from a seed bubble is introduced. The experimental results indicate that an in-situ processing pressure change will result in either a transient change in pore diameter or a complete termination of pore growth, indicating that pressure changes can be used as a control parameter to terminate bubble growth. A simple analytical model has been introduced to explain the experimental observations.
Gas turbine engine active clearance control
NASA Technical Reports Server (NTRS)
Deveau, Paul J. (Inventor); Greenberg, Paul B. (Inventor); Paolillo, Roger E. (Inventor)
1985-01-01
Method for controlling the clearance between rotating and stationary components of a gas turbine engine are disclosed. Techniques for achieving close correspondence between the radial position of rotor blade tips and the circumscribing outer air seals are disclosed. In one embodiment turbine case temperature modifying air is provided in flow rate, pressure and temperature varied as a function of engine operating condition. The modifying air is scheduled from a modulating and mixing valve supplied with dual source compressor air. One source supplies relatively low pressure, low temperature air and the other source supplies relatively high pressure, high temperature air. After the air has been used for the active clearance control (cooling the high pressure turbine case) it is then used for cooling the structure that supports the outer air seal and other high pressure turbine component parts.
Freitas, João Batista de; Tavares, Agostinho; Kohlmann, Osvaldo; Zanella, Maria Tereza; Ribeiro, Artur Beltrame
2002-08-01
To assess hypertension control rates in a specialized university-affiliated medical department, the influence of sex, diabetes, and obesity on that control, and the strategies for the treatment of hypertension. We carried out a cross-sectional study with 1,210 patients followed up for at least 6 months. Information was gathered from medical and nursing records and comprised the following data: sex, age, weight, height, abdominal and hip circumferences, blood pressure, and class and number of the antihypertensive drugs prescribed. To assess obesity, we used body mass index and waist/hip ratio. Blood pressure was considered under control when its levels were below 140/90 mmHg. The study consisted of 73% females and 27% males. Most females (31.7%) were 50 to 59 years of age, and most males (28.3%) were 60 to 69 years. The blood pressure control rate found was 20.9% for the 1,210 patients and 23.4% for the hypertensive diabetic patients (n=290). Despite the low control rates found, 70% of the patients used 1 or 2 antihypertensive medications. A high prevalence of obesity (38%) was observed, and females had a greater abdominal obesity index than males did (90% vs 82%, p<0.05). Patients with a greater body mass index had less control of blood pressure. The percentage of hypertensive patients with controlled blood pressure levels was low and was associated with a high prevalence of obesity. These data indicate the need for reviewing the strategies of global treatment for hypertension.
Blue, Nathan R; Murray-Krezan, Cristina; Drake-Lavelle, Shana; Weinberg, Daniel; Holbrook, Bradley D; Katukuri, Vivek R; Leeman, Lawrence; Mozurkewich, Ellen L
2018-06-01
Nonsteroidal antiinflammatory drug use has been shown to increase blood pressure in nonpregnant adults. Because of this, the American College of Obstetricians and Gynecologists suggests avoiding their use in women with postpartum hypertension; however, evidence to support this recommendation is lacking. Our goal was to test the hypothesis that nonsteroidal antiinflammatory drugs, such as ibuprofen, adversely affect postpartum blood pressure control in women with preeclampsia with severe features. At delivery, we randomized women with preeclampsia with severe features to receive around-the-clock oral dosing with either 600 mg of ibuprofen or 650 mg of acetaminophen every 6 hours. Dosing began within 6 hours after delivery and continued until discharge, with opioid analgesics available as needed for breakthrough pain. Study drugs were encapsulated in identical capsules such that patients, nurses, and physicians were masked to study allocation. Exclusion criteria were serum aspartate aminotransferase or alanine aminotransferase >200 mg/dL, serum creatinine >1.0 mg/dL, infectious hepatitis, gastroesophageal reflux disease, age <18 years, or current incarceration. Our primary outcome was the duration of severe-range hypertension, defined as the time (in hours) from delivery to the last blood pressure ≥160/110 mm Hg. Secondary outcomes were time from delivery to last blood pressure ≥150/100 mm Hg, mean arterial pressure, need for antihypertensive medication at discharge, prolongation of hospital stay for blood pressure control, postpartum use of short-acting antihypertensives for acute blood pressure control, and opioid use for breakthrough pain. We analyzed all outcome data according to intention-to-treat principles. We assessed 154 women for eligibility, of whom 100 met entry criteria, agreed to participate, and were randomized to receive postpartum ibuprofen or acetaminophen for first-line pain control. Seven patients crossed over or did not receive their allocated study drug, and 93 completed the study protocol in their assigned groups. We found no differences in baseline characteristics between groups, including mode of delivery, body mass index, parity, race, chronic hypertension, and maximum blood pressure prior to delivery. We did not find a difference in the duration of severe-range hypertension in the ibuprofen vs acetaminophen groups (35.3 vs 38.0 hours, P = .30). There were no differences between groups in the secondary outcome measures of time from delivery to last blood pressure ≥150/100 mm Hg, postpartum mean arterial pressure, maximum postpartum systolic or diastolic blood pressures, any postpartum blood pressure ≥160/110 mm Hg, short-acting antihypertensive use for acute blood pressure control, length of postpartum stay, need to extend postpartum stay for blood pressure control, antihypertensive use at discharge, or opioid use for inadequate pain control. In a subgroup analysis of patients who experienced severe-range hypertension, the mean time to blood pressure control in the acetaminophen group was 68.4 hours and ibuprofen group was 56.7 hours (P = .26). At 6 weeks postpartum, there were no differences between groups in the rates of obstetric triage visits, hospital readmissions, continued opioid use, or continued antihypertensive use. The first-line use of ibuprofen rather than acetaminophen for postpartum pain did not lengthen the duration of severe-range hypertension in women with preeclampsia with severe features. Copyright © 2018 Elsevier Inc. All rights reserved.
Linear Mechanisms and Pressure Fluctuations in Wall Turbulence
NASA Astrophysics Data System (ADS)
Septham, Kamthon; Morrison, Jonathan
2014-11-01
Full-domain, linear feedback control of turbulent channel flow at Reτ <= 400 via vU' at low wavenumbers is an effective method to attenuate turbulent channel flow such that it is relaminarised. The passivity-based control approach is adopted and explained by the conservative characteristics of the nonlinear terms contributing to the Reynolds-Orr equation (Sharma et al .Phys .Fluids 2011). The linear forcing acts on the wall-normal velocity field and thus the pressure field via the linear (rapid) source term of the Poisson equation for pressure fluctuations, 2U'∂v/∂x . The minimum required spanwise wavelength resolution without losing control is constant at λz+ = 125, based on the wall friction velocity at t = 0 . The result shows that the maximum forcing is located at y+ ~ 20 , corresponding to the location of the maximum in the mean-square pressure gradient. The effectiveness of linear control is qualitatively explained by Landahl's theory for timescales, in that the control proceeds via the shear interaction timescale which is much shorter than both the nonlinear and viscous timescales. The response of the rapid (linear) and slow (nonlinear) pressure fluctuations to the linear control is examined and discussed.
Goozée, Justine V; Murdoch, Bruce E; Theodoros, Deborah G
2002-01-01
A miniature pressure transducer was used to assess the interlabial contact pressures produced by a group of 19 adults (mean age 30.6 years) with dysarthria following severe traumatic brain injury (TBI) during a set of speech and nonspeech tasks. Ten parameters relating to lip strength, endurance, rate of movement and lip pressure accuracy and stability were measured from the nonspeech tasks. The results attained by the TBI group were compared against a group of 19 age- and sex-matched control subjects. Significant differences between the groups were found for maximum interlabial contact pressure, maximum rate of repetition of maximum pressure, and lip pressure accuracy at 50 and 10% levels of maximum pressure. In regards to speech, the interlabial contact pressures generated by the TBI group and control group did not differ significantly. When expressed as percentages of maximum pressure, however, the TBI group's interlabial pressures appeared to have been generated with greater physiological effort. Copyright 2002 S. Karger AG, Basel
Peristaltic pump-based low range pressure sensor calibration system
NASA Astrophysics Data System (ADS)
Vinayakumar, K. B.; Naveen Kumar, G.; Nayak, M. M.; Dinesh, N. S.; Rajanna, K.
2015-11-01
Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.
30 CFR 250.616 - Blowout prevention equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pressure rating of the BOP system and system components shall exceed the expected surface pressure to which they may be subjected. If the expected surface pressure exceeds the rated working pressure of the... pressure limitations that will be applied during each mode of pressure control. (b) The minimum BOP system...
30 CFR 250.616 - Blowout prevention equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pressure rating of the BOP system and system components shall exceed the expected surface pressure to which they may be subjected. If the expected surface pressure exceeds the rated working pressure of the... pressure limitations that will be applied during each mode of pressure control. (b) The minimum BOP system...
30 CFR 250.615 - Blowout prevention equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pressure rating of the BOP system and system components shall exceed the expected surface pressure to which they may be subjected. If the expected surface pressure exceeds the rated working pressure of the... pressure limitations that will be applied during each mode of pressure control. (b) The minimum BOP system...
Pressure variable orifice for hydraulic control valve
NASA Technical Reports Server (NTRS)
Ammerman, R. L.
1968-01-01
Hydraulic valve absorbs impact energy generated in docking or joining of two large bodies by controlling energy release to avoid jarring shock. The area of exit porting presented to the hydraulic control fluid is directly proportional to the pressure acting on the fluid.
NASA Technical Reports Server (NTRS)
Walker, Neil (Inventor); Day, Stanley G. (Inventor); Collopy, Paul D. (Inventor); Bennett, George W. (Inventor)
1988-01-01
An integrated control system for coaxial counterrotating aircraft propulsors driven by a common gas turbine engine. The system establishes an engine pressure ratio by control of fuel flow and uses the established pressure ratio to set propulsor speed. Propulsor speed is set by adjustment of blade pitch.
Control device for prosthetic urinary sphincter cuff
NASA Technical Reports Server (NTRS)
Reinicke, Robert H. (Inventor)
1983-01-01
A device for controlling flow of fluid to and from a resilient inflatable cuff implanted about the urethra to control flow of urine therethrough. The device comprises a flexible bulb reservoir and a control unit that includes a manually operated valve that opens automatically when the bulb is squeezed to force fluid into the cuff for closing the urethra. The control unit also includes a movable valve seat member having a relatively large area exposed to pressure of fluid in a chamber that is connected to the cuff and which moves to a position in which the valve member is unseated by an abutment when fluid pressure in the chamber exceeds a predetermined value to thereby relieve excess fluid pressure in the cuff. The arrangement is such that the valve element is held closed against the seat member by the full differential in fluid pressures acting on both sides of the valve element until the seat member is moved away from the valve element to thus insure positive closing of the valve element until the seat member is moved out of engagement with the valve element by excess pressure differential.
Chapellier, R.A.
1960-05-24
BS>A drive mechanism was invented for the control rod of a nuclear reactor. Power is provided by an electric motor and an outside source of fluid pressure is utilized in conjunction with the fluid pressure within the reactor to balance the loadings on the motor. The force exerted on the drive mechanism in the direction of scramming the rod is derived from the reactor fluid pressure so that failure of the outside pressure source will cause prompt scramming of the rod.
Automatic safety rod for reactors. [LMFBR
Germer, J.H.
1982-03-23
An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.
Automatic safety rod for reactors
Germer, John H.
1988-01-01
An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-core flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.
Kichou, B; Henine, N; Kichou, L; Boubchir, M A; Ait Said, M A; Zatout, M; Hammouche, A; Mazeghrane, A; Madiou, A; Benbouabdellah, M
2018-06-01
To compare a so-called an "accelerated" antihypertensive strategy to a "standard" strategy, in terms of blood pressure control rates and adverse events. Prospective open-label randomized controlled trial, which included consecutive hypertensive patients, newly diagnosed, 40 to 70 years old, with no prior antihypertensive treatment. Hypertension was diagnosed if office blood pressure was≥140/90mmHg, confirmed by an increase of Home or a daytime ambulatory blood pressure. The patients were randomly assigned according to 1:1 ratio to an "accelerated" strategy or to a "standard" strategy. The primary end-point was the rate of blood pressure control at 12weeks. The secondary end-point was the rate of adverse events (a safety end-point). We recruited 268 patients (132 in the "accelerated" strategy group), with a mean age of 55 years and 62% of men. The mean office blood pressure at baseline was 168/95mmHg. The clinical characteristics were on average similar between the 2 treatment groups. At 12 weeks, the rates of blood pressure control were 63.6% in the "accelerated" strategy and 38.2% in the "standard" strategy (P<0.001). There was no significantly difference between the rates of adverse events in the 2 strategies (6.06% versus 5.14%; P=0.8). The "accelerated" antihypertensive strategy was more effective than a standard one, in terms of blood pressure control, without an increase in adverse events rate. This could translate into a future cardiovascular events reduction. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Method for pressure modulation of turbine sidewall cavities
Leone, Sal Albert; Book, Matthew David; Banares, Christopher R.
2002-01-01
A method is provided for controlling cooling air flow for pressure modulation of turbine components, such as the turbine outer sidewall cavities. The pressure at which cooling and purge air is supplied to the turbine outer side wall cavities is modulated, based on compressor discharge pressure (Pcd), thereby to generally maintain the back flow margin (BFM) so as to minimize excessive leakage and the consequent performance deterioration. In an exemplary embodiment, the air pressure within the third stage outer side wall cavity and the air pressure within the fourth stage outer side wall cavity are each controlled to a respective value that is a respective prescribed percentage of the concurrent compressor discharge pressure. The prescribed percentage may be determined from a ratio of the respective outer side wall pressure to compressor discharge pressure at Cold Day Turn Down (CDTD) required to provide a prescribed back flow margin.
System for pressure modulation of turbine sidewall cavities
Leone, Sal Albert; Book, Matthew David; Banares, Christopher R.
2002-01-01
A system and method are provided for controlling cooling air flow for pressure modulation of turbine components, such as the turbine outer sidewall cavities. The pressure at which cooling and purge air is supplied to the turbine outer side wall cavities is modulated, based on compressor discharge pressure (Pcd), thereby to generally maintain the back flow margin (BFM) so as to minimize excessive leakage and the consequent performance deterioration. In an exemplary embodiment, the air pressure within the third stage outer side wall cavity and the air pressure within the fourth stage outer side wall cavity are each controlled to a respective value that is a respective prescribed percentage of the concurrent compressor discharge pressure. The prescribed percentage may be determined from a ratio of the respective outer side wall pressure to compressor discharge pressure at Cold Day Turn Down (CDTD) required to provide a prescribed back flow margin.
Differential pressure pin discharge apparatus
Oakley, David J.
1987-02-03
Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in the low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pin passageway extending through the assembly.
Differential pressure pin discharge apparatus
Oakley, D.J.
1984-05-30
Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in the low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pins passageway extending through the assembly.
Differential pressure pin discharge apparatus
Oakley, David J.
1987-01-01
Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in the low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pin passageway extending through the assembly.
Stamler, Jeremiah; Brown, Ian J; Yap, Ivan K S; Chan, Queenie; Wijeyesekera, Anisha; Garcia-Perez, Isabel; Chadeau-Hyam, Marc; Ebbels, Timothy M D; De Iorio, Maria; Posma, Joram; Daviglus, Martha L; Carnethon, Mercedes; Holmes, Elaine; Nicholson, Jeremy K; Elliott, Paul
2013-12-01
Black compared with non-Hispanic white Americans have higher systolic and diastolic blood pressure and rates of prehypertension/hypertension. Reasons for these adverse findings remain obscure. Analyses here focused on relations of foods/nutrients/urinary metabolites and higher black blood pressure for 369 black compared with 1190 non-Hispanic white Americans aged 40 to 59 years from 8 population samples. Multiple linear regression, standardized data from four 24-hour dietary recalls per person, two 24-hour urine collections, and 8 blood pressure measurements were used to quantitate the role of foods, nutrients, and metabolites in higher black blood pressure. Compared with non-Hispanic white Americans, blacks' average systolic/diastolic pressure was higher by 4.7/3.4 mm Hg (men) and 9.0/4.8 mm Hg (women). Control for higher body mass index of black women reduced excess black systolic/diastolic pressure to 6.8/3.8 mm Hg. Lesser intake of vegetables, fruits, grains, vegetable protein, glutamic acid, starch, fiber, minerals, and potassium, and higher intake of processed meats, pork, eggs, and sugar-sweetened beverages, along with higher cholesterol and higher Na/K ratio, related to in higher black blood pressure. Control for 11 nutrient and 10 non-nutrient correlates reduced higher black systolic/diastolic pressure to 2.3/2.3 mm Hg (52% and 33% reduction in men) and to 5.3/2.8 mm Hg (21% and 27% reduction in women). Control for foods/urinary metabolites had little further influence on higher black blood pressure. Less favorable multiple nutrient intake by blacks than non-Hispanic white Americans accounted, at least in part, for higher black blood pressure. Improved dietary patterns can contribute to prevention/control of more adverse black blood pressure levels.
The effect of continuous positive airway pressure on middle ear pressure.
Sivri, Bekir; Sezen, Ozan Seymen; Akbulut, Sevtap; Coskuner, Temel
2013-05-01
To investigate the effect of continuous positive airway pressure (CPAP) on middle ear pressure in patients with obstructive sleep apnea syndrome (OSAS). Prospective clinical case-control study. Seventy-eight patients with moderate and severe OSAS (the mean apnea-hypopnea indexes were 22.70 ± 3.59 and 48.59 ± 12.50, respectively) using CPAP (study group) and 60 patients with no sleep apnea syndrome (control group) were included in the study. Forty-two of the patients were female and 96 were male. The mean age in the study group was 47.38 ± 6.23, whereas it was 46.10 ± 11.96 in the control group (P > .05). The middle ear pressure of all study subjects was evaluated with tympanometry at the beginning of the study and 6 months later. Tympanometric measurements of both groups were compared. Furthermore, the same data for the study group were also evaluated according to CPAP pressure levels. The middle ear peak pressure values of the patients in the study group were significantly increased from -63.04 ± 55.82 daPa to -39.6 ± 27.72 daPa after 6 months (P < .01). The middle ear pressure in the control group was found to be -13.26 ± 22.60 daPa at the beginning of the study and -13.60 ± 38.82 daPa after 6 months (P > .05). The mean middle ear pressure level was significantly higher in patients using CPAP at 12 to 14 cm H2 O pressure than in those using CPAP at 8 to 10 cm H2 O pressure (P < .05). There was a significant increase in the middle ear pressure of patients using CPAP regularly for 6 months. This increase was proportional to the pressure level of the CPAP device. 3b. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Osmotic-pressure-controlled concentration of colloidal particles in thin-shelled capsules
NASA Astrophysics Data System (ADS)
Kim, Shin-Hyun; Park, Jin-Gyu; Choi, Tae Min; Manoharan, Vinothan N.; Weitz, David A.
2014-01-01
Colloidal crystals are promising structures for photonic applications requiring dynamic control over optical properties. However, for ease of processing and reconfigurability, the crystals should be encapsulated to form ‘ink’ capsules rather than confined in a thin film. Here we demonstrate a class of encapsulated colloidal photonic structures whose optical properties can be controlled through osmotic pressure. The ordering and separation of the particles within the microfluidically created capsules can be tuned by changing the colloidal concentration through osmotic pressure-induced control of the size of the individual capsules, modulating photonic stop band. The rubber capsules exhibit a reversible change in the diffracted colour, depending on osmotic pressure, a property we call osmochromaticity. The high encapsulation efficiency and capsule uniformity of this microfluidic approach, combined with the highly reconfigurable shapes and the broad control over photonic properties, make this class of structures particularly suitable for photonic applications such as electronic inks and reflective displays.
Blood Pressure Control in Hypertensive Patients in the "Hiperdia Program": A Territory-Based Study
de Souza, Clarita Silva; Stein, Airton Tetelbom; Bastos, Gisele Alsina Nader; Pellanda, Lucia Campos
2014-01-01
Background Systemic hypertension is highly prevalent and an important risk factor for cardiovascular events. Blood pressure control in hypertensive patients enrolled in the Hiperdia Program, a program of the Single Health System for the follow-up and monitoring of hypertensive patients, is still far below the desired level. Objective To describe the epidemiological profile and to assess blood pressure control of patients enrolled in Hiperdia, in the city of Novo Hamburgo (State of Rio Grande do Sul, Brazil). Methods Cross-sectional study with a stratified cluster random sample, including 383 adults enrolled in the Hiperdia Program of the 15 Basic Health Units of the city of Porto Alegre, conducted between 2010 and 2011. Controlled blood pressure was defined as ≤140 mmHg × 90 mmHg. The hypertensive patients were interviewed and their blood pressure was measured using a calibrated aneroid device. Prevalence ratios (PR) with 95% confidence interval, Wald's χ2 test, and simple and multiple Poisson regression were used in the statistical analysis. Results The mean age was 63 ± 10 years, and most of the patients were females belonging to social class C, with a low level of education, a sedentary lifestyle, and family history positive for systemic hypertension. Diabetes mellitus (DM) was observed in 31%; adherence to the antihypertensive treatment in 54.3%; and 33.7% had their blood pressure controlled. DM was strongly associated with inadequate BP control, with only 15.7% of the diabetics showing BP considered as controlled. Conclusion Even for hypertensive patients enrolled in the Hiperdia Program, BP control is not satisfactorily reached or sustained. Diabetic hypertensive patients show the most inappropriate BP control. PMID:25004419
Sequist, Thomas D.; Ayanian, John Z.; Shaykevich, Shimon; Fairchild, David G.; Orav, E. John; Bates, David W.
2008-01-01
BACKGROUND We conducted a cluster randomized controlled trial to examine the effectiveness of computerized decision support (CDS) designed to improve hypertension care and outcomes in a racially diverse sample of primary care patients. METHODS We randomized 2,027 adult patients receiving hypertension care in 14 primary care practices to either 18 months of their physicians receiving CDS for each hypertensive patient or to usual care without computerized support for the control group. We assessed prescribing of guideline-recommended drug therapy and levels of blood pressure control for patients in each group and examined if the effects of the intervention differed by patients’ race/ethnicity using interaction terms. MEASUREMENTS AND MAIN RESULTS Rates of blood pressure control were 42% at baseline and 46% at the outcome visit with no significant differences between groups. After adjustment for patients’ demographic and clinical characteristics, number of prior visits, and levels of baseline blood pressure control, there were no differences between intervention groups in the odds of outcome blood pressure control. The use of CDS to providers significantly improved Joint National Committee (JNC) guideline adherent medication prescribing compared to usual care (7% versus 5%, P < 0.001); the effects of the intervention remained after multivariable adjustment (odds ratio [OR] 1.39 [CI, 1.13–1.72]) and the effects of the intervention did not differ by patients’ race and ethnicity. CONCLUSIONS CDS improved appropriate medication prescribing with no improvement in disparities in care and overall blood pressure control. Future work focusing on improvement of these interventions and the study of other practical interventions to reduce disparities in hypertension-related outcomes is needed. PMID:18373141
Code of Federal Regulations, 2010 CFR
2010-10-01
... LIQUID HAZARDOUS MATERIAL CARGOES Temperature or Pressure Control Installations § 151.40-2 Materials. Materials used in the construction of temperature or pressure control systems shall be suitable for the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... LIQUID HAZARDOUS MATERIAL CARGOES Temperature or Pressure Control Installations § 151.40-2 Materials. Materials used in the construction of temperature or pressure control systems shall be suitable for the...
Code of Federal Regulations, 2014 CFR
2014-10-01
... LIQUID HAZARDOUS MATERIAL CARGOES Temperature or Pressure Control Installations § 151.40-2 Materials. Materials used in the construction of temperature or pressure control systems shall be suitable for the...
Code of Federal Regulations, 2012 CFR
2012-10-01
... LIQUID HAZARDOUS MATERIAL CARGOES Temperature or Pressure Control Installations § 151.40-2 Materials. Materials used in the construction of temperature or pressure control systems shall be suitable for the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... LIQUID HAZARDOUS MATERIAL CARGOES Temperature or Pressure Control Installations § 151.40-2 Materials. Materials used in the construction of temperature or pressure control systems shall be suitable for the...
Control method for turbocharged diesel engines having exhaust gas recirculation
Kolmanovsky, Ilya V.; Jankovic, Mrdjan J; Jankovic, Miroslava
2000-03-14
A method of controlling the airflow into a compression ignition engine having an EGR and a VGT. The control strategy includes the steps of generating desired EGR and VGT turbine mass flow rates as a function of the desired and measured compressor mass airflow values and exhaust manifold pressure values. The desired compressor mass airflow and exhaust manifold pressure values are generated as a function of the operator-requested fueling rate and engine speed. The EGR and VGT turbine mass flow rates are then inverted to corresponding EGR and VGT actuator positions to achieve the desired compressor mass airflow rate and exhaust manifold pressure. The control strategy also includes a method of estimating the intake manifold pressure used in generating the EGR valve and VGT turbine positions.
Growth of a Bacterium Under a High-Pressure Oxy-Helium Atmosphere †
Taylor, Craig D.
1979-01-01
Growth of a barotolerant marine organism, EP-4, in a glutamate medium equilibrated with an oxy-helium atmosphere at 500 atmospheres (atm; total pressure) (20°C) was compared with control cultures incubated at hydrostatic pressures of 1 and 500 atm. Relative to the 1-atm control culture, incubation of EP-4 at 500 atm in the absence of an atmosphere resulted in an approximately fivefold reduction in the growth rate and a significant but time variant reduction in the rate constants for the incorporation of substrate into cell material and respiration. Distinct from the pressurized control and separate from potential effects of dissolution of helium upon decompression of subsamples, exposure of the organism to high-pressure oxy-helium resulted in either a loss of viability of a large fraction of the cells or the arrest of growth for one-third of the experimental period. After these initial effects, however, the culture grew exponentially at a rate which was three times greater than the 500-atm control culture. The rate constant for the incorporation of substrate into cell material was also enhanced twofold in the presence of high-pressure oxy-helium. Dissolved oxygen was well controlled in all of the cultures, minimizing any potential toxic effects of this gas. PMID:16345337
Energy efficient continuous flow ash lockhopper
NASA Technical Reports Server (NTRS)
Collins, Earl R., Jr. (Inventor); Suitor, Jerry W. (Inventor); Dubis, David (Inventor)
1989-01-01
The invention relates to an energy efficient continuous flow ash lockhopper, or other lockhopper for reactor product or byproduct. The invention includes an ash hopper at the outlet of a high temperature, high pressure reactor vessel containing heated high pressure gas, a fluidics control chamber having an input port connected to the ash hopper's output port and an output port connected to the input port of a pressure letdown means, and a control fluid supply for regulating the pressure in the control chamber to be equal to or greater than the internal gas pressure of the reactor vessel, whereby the reactor gas is contained while ash is permitted to continuously flow from the ash hopper's output port, impelled by gravity. The main novelty resides in the use of a control chamber to so control pressure under the lockhopper that gases will not exit from the reactor vessel, and to also regulate the ash flow rate. There is also novelty in the design of the ash lockhopper shown in two figures. The novelty there is the use of annular passages of progressively greater diameter, and rotating the center parts on a shaft, with the center part of each slightly offset from adjacent ones to better assure ash flow through the opening.
NASA Astrophysics Data System (ADS)
Reedy, Todd Mitchell
An experimental investigation evaluating the effects of flow control on the near-wake downstream of a blunt-based axisymmetric body in supersonic flow has been conducted. To better understand and control the physical phenomena that govern these massively separated high-speed flows, this research examined both passive and active flow-control methodologies designed to alter the stability characteristics and structure of the near-wake. The passive control investigation consisted of inserting splitter plates into the recirculation region. The active control technique utilized energy deposition from multiple electric-arc plasma discharges placed around the base. The flow-control authority of both methodologies was evaluated with experimental diagnostics including particle image velocimetry, schlieren photography, surface flow visualization, pressure-sensitive paint, and discrete surface pressure measurements. Using a blowdown-type wind tunnel reconstructed specifically for these studies, baseline axisymmetric experiments without control were conducted for a nominal approach Mach number of 2.5. In addition to traditional base pressure measurements, mean velocity and turbulence quantities were acquired using two-component, planar particle image velocimetry. As a result, substantial insight was gained regarding the time-averaged and instantaneous near-wake flow fields. This dataset will supplement the previous benchmark point-wise laser Doppler velocimetry data of Herrin and Dutton (1994) for comparison with new computational predictive techniques. Next, experiments were conducted to study the effects of passive triangular splitter plates placed in the recirculation region behind a blunt-based axisymmetric body. By dividing the near-wake into 1/2, 1/3, and 1/4 cylindrical regions, the time-averaged base pressure distribution, time-series pressure fluctuations, and presumably the stability characteristics were altered. While the spatial base pressure distribution was influenced considerably, the area-integrated pressure was only slightly affected. Normalized RMS levels indicate that base pressure fluctuations were significantly reduced with the addition of the splitter plates. Power-spectral-density estimates revealed a spectral broadening of fluctuating energy for the 1/2 cylinder configuration and a bimodal distribution for the 1/3 and 1/4 cylinder configurations. It was concluded that the recirculation region is not the most sensitive location to apply flow control; rather, the shear layer may be a more influential site for implementing flow control methodologies. For active flow control, pulsed plasma-driven fluidic actuators were investigated. Initially, the performance of two plasma actuator designs was characterized to determine their potential as supersonic flow control devices. For the first actuator considered, the pulsed plasma jet, electro-thermal heating from an electric discharge heats and pressurizes gas in a small cavity which is exhausted through a circular orifice forming a synthetic jet. Depending on the electrical energy addition, peak jet velocities ranged between 130 to nearly 500 m/s when exhausted to quiescent, ambient conditions. The second plasma actuator investigated is the localized arc filament plasma actuator (LAFPA), which created fluidic perturbations through the rapid, local thermal heating, generated from an electric arc discharge between two electrodes within a shallow open cavity. Electrical and emission properties of the LAFPA were first documented as a function of pressure in a quiescent, no-flow environment. Rotational and vibrational temperatures from N2 spectra were obtained for select plasma conditions and ambient pressures. Results further validate that the assumption of optically thin conditions for these electric arc plasmas is not necessary valid, even at low ambient pressure. Breakdown voltage, sustained plasma voltage, power, and energy per pulse were demonstrated to decrease with decreasing pressure. Implementing an array of eight electric arcs circumferentially around the base near the corner expansion, the LAFPA actuators were shown to produce significant disturbances to the separating shear layer of the base flow and cause modest influences on the base pressure when actuated over a range of high frequencies (O(kHz)), forcing modes, duty cycles, and electrical currents. To tailor the plasma actuator toward the specific flow control application of the separated base flow, several actuator geometries and energy additions were evaluated. Displaying the ability to produce disturbances in the shear layer, an open cavity actuator design outperformed the other geometries consisting of a confined cavity with an exhaust orifice. Increases in duty cycle (between 2% and 6%) and in plasma current (1/4 to 4 amps) were shown to produce large velocity disturbances causing a decrease in average base pressure. At 4 amps and a maximum duty cycle of 6%, the largest measured change in area-weighted base pressure, near -1.5%, was observed for the axisymmetric forcing mode. Positive changes in base pressure were experienced (as much as 1% increase from the no-control) for the vertical and horizontal flapping modes.
ASSOCIATION OF DAIRY CONSUMPTION AND 24-HOUR BLOOD PRESSURE IN OLDER ADULTS WITH HYPERTENSION.
Lana, Alberto; Banegas, Jose R; Guallar-Castillón, Pilar; Rodríguez-Artalejo, Fernando; Lopez-Garcia, Esther
2018-05-25
The aim was to examine the association between habitual consumption of dairy products and 24-h ambulatory blood pressure monitoring among older adults with hypertension. We conducted an analysis of 715 community-living hypertensive adults aged ≥60. Habitual dairy consumption was assessed with a validated diet history. Blood pressure was recorded by 24-hour ambulatory blood pressure monitoring; controlled blood pressure was defined as 24-hour blood pressure <130/80 mm Hg in those under drug treatment. Analyses were adjusted for main confounders, including diet, hypertension duration, and being on antihypertensive treatment. After adjustment for confounders, consumers of ≥7 servings/wk of whole milk/yogurt had a diastolic blood pressure 1.40 mm Hg higher (95% confidence interval: 0.01, 2.81) than consumers of <1 serving/wk. By contrast, consumers of ≥7 servings/wk of low-fat milk/yogurt had a diastolic blood pressure 1.74 mm Hg lower (95% confidence interval: -3.26, -0.23) than consumers of <1 serving/wk. Moreover, the odds ratio (95% confidence interval) for controlled blood pressure was 1.83 (1.05-3.08) for those consuming ≥7 servings/wk of low-fat milk/yogurt, when comparing with consumers of <1 serving/wk. Cheese consumption was not associated with blood pressure. Regular consumption of low-fat milk/yogurt was associated with lower 24-h diastolic blood pressure and with better blood pressure control among older adults with hypertension. Copyright © 2018. Published by Elsevier Inc.
2013-01-01
Background Medical treatment of hypertension is not always sufficient to achieve blood pressure control. Despite this, previous studies on supplementary therapies, such as yoga, are relatively few. We investigated the effects of two yoga interventions on blood pressure and quality of life in patients in primary health care diagnosed with hypertension. Methods Adult patients (age 20–80 years) with diagnosed hypertension were identified by an electronic chart search at a primary health care center in southern Sweden. In total, 83 subjects with blood pressure values of 120–179/≤109 mmHg at baseline were enrolled. At baseline, the patients underwent standardized blood pressure measurement at the health care center and they completed a questionnaire on self-rated quality of life (WHOQOL-BREF). There were three groups: 1) yoga class with yoga instructor (n = 28); 2) yoga at home (n = 28); and 3) a control group (n = 27). The participants were matched at the group level for systolic blood pressure. After 12 weeks of intervention, the assessments were performed again. At baseline a majority of the patients (92%) were on antihypertensive medication, and the patients were requested not to change their medication during the study. Results The yoga class group showed no improvement in blood pressure or self-rated quality of life, while in the yoga at home group there was a decline in diastolic blood pressure of 4.4 mmHg (p < 0.05) compared to the control group. Moreover, the yoga at home group showed significant improvement in self-rated quality of life compared to the control group (p < 0.05). Conclusions A short yoga program for the patient to practice at home seems to have an antihypertensive effect, as well as a positive effect on self-rated quality of life compared to controls. This implies that simple yoga exercises may be useful as a supplementary blood pressure therapy in addition to medical treatment when prescribed by primary care physicians. Trial registration ClinicalTrials.gov (NCT01302535) PMID:24314119
142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN ...
142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN IN SOUTHWEST PORTION OF CONTROL ROOM (214), LSB (BLDG. 751), FACING WEST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Active load control during rolling maneuvers. [performed in the Langley Transonic Dynamics Tunnel
NASA Technical Reports Server (NTRS)
Woods-Vedeler, Jessica A.; Pototzky, Anthony S.; Hoadley, Sherwood T.
1994-01-01
A rolling maneuver load alleviation (RMLA) system has been demonstrated on the active flexible wing (AFW) wind tunnel model in the Langley Transonic Dynamics Tunnel (TDT). The objective was to develop a systematic approach for designing active control laws to alleviate wing loads during rolling maneuvers. Two RMLA control laws were developed that utilized outboard control-surface pairs (leading and trailing edge) to counteract the loads and that used inboard trailing-edge control-surface pairs to maintain roll performance. Rolling maneuver load tests were performed in the TDT at several dynamic pressures that included two below and one 11 percent above open-loop flutter dynamic pressure. The RMLA system was operated simultaneously with an active flutter suppression system above open-loop flutter dynamic pressure. At all dynamic pressures for which baseline results were obtained, torsion-moment loads were reduced for both RMLA control laws. Results for bending-moment load reductions were mixed; however, design equations developed in this study provided conservative estimates of load reduction in all cases.
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Markusic, T. E.; Stanojev, B. J.
2007-01-01
Two prototype bismuth propellant feed systems were constructed and operated in conjunction with a propellant vaporizer. One system provided bismuth to a vaporizer using gas pressurization but did not include a means to measure the flow rate. The second system incorporated an electromagnetic pump to provide fine control of the hydrostatic pressure and a new type of in-line flow sensor that was developed for accurate, real-time measurement of the mass flow rate. High-temperature material compatibility was a driving design requirement for the pump and flow sensor, leading to the selection of Macor for the main body of both components. Posttest inspections of both components revealed no degradation of the material. The gas pressurization system demonstrated continuous pressure control over a range from zero to 200 torr. In separate proof-of-concept experiments, the electromagnetic pump produced a linear pressure rise as a function of current that compared favorably with theoretical pump pressure predictions, producing a pressure rise of 10 kPa at 30 A. Preliminary flow sensor operation indicated a bismuth flow rate of 6 mg/s with an uncertainty of plus or minus 6%. An electronics suite containing a real-time controller was successfully used to control the entire system, simultaneously monitoring all power supplies and performing data acquisition duties.
Aoki, Shiro; Hosomi, Naohisa; Nezu, Tomohisa; Teshima, Tsukasa; Sugii, Hitoshi; Nagahama, Shinobu; Kurose, Yoshiki; Maruyama, Hirofumi; Matsumoto, Masayasu
2017-01-01
Blood pressure control is important in post-stroke hypertensive patients and antihypertensive treatment is recommended for such patients. Ca-channel blockers are recommended as the medications of choice for the treatment of post-stroke patients. Here, we report the results of a large-scale prospective post-marketing surveillance study of post-stroke hypertensive patients (n = 2667, male 60.4%, 69.0 ± 10.9 years) treated with cilnidipine, with regard to blood pressure control and adverse reactions. Cilnidipine treatment caused a decrease in both clinic and home blood pressures 2 months after the beginning of treatment, and the decreased blood pressure was maintained until the end of 12 months' observation. The proportion of patients in whom clinic blood pressure was well controlled (<140/90 mmHg) increased from 21.5% to 65.3% in cilnidipine treatment, with no differences in effectiveness among the various clinical subtypes of stroke. In total, 346 adverse events occurred, with an overall incidence of 8.9% (238 of 2667 patients). In the elderly group, specifically, a fall and a hip fracture each occurred in 1 (0.1%) patient. These results indicate that cilnidipine was effective in treating uncontrolled blood pressure and was well tolerated in Japanese post-stroke hypertensive patients in a real-world clinical setting.
Design of a new controller to treat the obstructive sleep apnea
NASA Astrophysics Data System (ADS)
Netzel, Thomas
2002-06-01
The obstructive sleep apnoea (OSA) is a sleep related breathing disorder caused by a relaxation of the upper airway structure during the sleep that leads to a complete closure of the upper airway. The most successful therapy is the nasal continuous positive airway pressure (nCPAP) treatment that keeps the airway opened. More recent devices use an automatic adaptation of the applied pressure. Either the forced oscillation technique (FOT) or the evaluation of the inspiration flow contour are used to evaluate the severity of obstructions. Both methods have disadvantages that may lead to wrong applied pressures. Based on the precise measurement of airflow and mask pressure during nCPAP with a Weinmann SOMNOsmart and additional polysomnography a new parameter set is presented that uses the advantage of both methods to detect the obstructive sleep apnoea. To evaluate the applicability of this parameter set to control Auto-nCPAP-devices a fuzzy-controller is designed under MATLAB/Simulink using an A/D-D/A-converter to control the blower of the SOMNOsmart during Auto-nCPAP-therapy. Obstructive events are detected and treated with a rise of nCPAP-pressure depending on the inspiratory flow requirement. The pressure is lowered after the end of flow limited phases. Although temporary low pressures no oxygen desaturation is recognized by the pulse oxymeter.
A new electronic scanner of pressure designed for installation in wind-tunnel models
NASA Technical Reports Server (NTRS)
Coe, C. T.; Parra, G. T.; Kauffman, R. C.
1981-01-01
A new electronic scanner of pressure (ESOP) has been developed by NASA Ames Research Center for installation in wind-tunnel models. An ESOP system includes up to 20 pressure modules, each with 48 pressure transducers, an A/D converter, a microprocessor, a data controller, a monitor unit, and a heater controller. The system is sized so that the pressure modules and A/D converter module can be installed within an average-size model tested in the Ames Aerodynamics Division wind tunnels. This paper describes the ESOP system, emphasizing the main element of the system - the pressure module. The measured performance of the overall system is also presented.
Pressure Fluctuations in a Common-Rail Fuel Injection System
NASA Technical Reports Server (NTRS)
Rothrock, A M
1931-01-01
This report presents the results of an investigation to determine experimentally the instantaneous pressures at the discharge orifice of a common-rail fuel injection system in which the timing valve and cut-off valve were at some distance from the automatic fuel injection valve, and also to determine the methods by which the pressure fluctuations could be controlled. The results show that pressure wave phenomena occur between the high-pressure reservoir and the discharge orifice, but that these pressure waves can be controlled so as to be advantageous to the injection of the fuel. The results also give data applicable to the design of such an injection system for a high-speed compression-ignition engine.
System for controlling the flow of gas into and out of a gas laser
Alger, Terry; Uhlich, Dennis M.; Benett, William J.; Ault, Earl R.
1994-01-01
A modularized system for controlling the gas pressure within a copper vapor or like laser is described herein. This system includes a gas input assembly which serves to direct gas into the laser in a controlled manner in response to the pressure therein for maintaining the laser pressure at a particular value, for example 40 torr. The system also includes a gas output assembly including a vacuum pump and a capillary tube arrangement which operates within both a viscous flow region and a molecular flow region for drawing gas out of the laser in a controlled manner.
Hillebrand, Matthias; Nouri, Ghazaleh; Hametner, Bernhard; Parragh, Stephanie; Köster, Jelena; Mortensen, Kai; Schwarz, Achim; von Kodolitsch, Yskert; Wassertheurer, Siegfried
2016-05-06
The aim of this work is the investigation of measures of ambulatory brachial and aortic blood pressure and indices of arterial stiffness and aortic wave reflection in Marfan patients. A case-control study was conducted including patients with diagnosed Marfan syndrome following Ghent2 nosology and healthy controls matched for sex, age and daytime brachial systolic blood pressure. For each subject a 24 h ambulatory blood pressure and 24 h pulse wave analysis measurement was performed. All parameters showed a circadian pattern whereby pressure dipping was more pronounced in Marfan patients. During daytime only Marfan patients with aortic root surgery showed increased pulse wave velocity. In contrast, various nighttime measurements, wave reflection determinants and circadian patterns showed a significant difference. The findings of our study provide evidence that ambulatory measurement of arterial stiffness parameters is feasible and that these determinants are significantly different in Marfan syndrome patients compared to controls in particular at nighttime. Further investigation is therefore indicated.
Means and apparatus for throttling a dry pulverized solid material pump
Meyer, J. W.; Daniel, Jr, A. D.; Bonin, J. H.
1982-12-07
Method and apparatus are shown for control of continuous feeding of pulverized material to a high pressure container. A rotor is located within the high pressure container. The pulverized material is fed from a feed hopper through a stationary feed pipe to a vented spin-up zone chamber to a plurality of sprues mounted in the rotor. Control of the pressure within control nozzles downstream from the sprues adjusts the flow rate of coal through the sprues. 9 figs.
Means and apparatus for throttling a dry pulverized solid material pump
Meyer, John W [Palo Alto, CA; Daniel, Jr., Arnold D.; Bonin, John H [Sunnyvale, CA
1982-01-01
Method and apparatus are shown for control of continuous feeding of pulverized material to a high pressure container. A rotor is located within the high pressure container. The pulverized material is fed from a feed hopper through a stationary feed pipe to a vented spin-up zone chamber to a plurality of sprues mounted in the rotor. Control of the pressure within control nozzles downstream from the sprues adjusts the flow rate of coal through the sprues.
NASA Technical Reports Server (NTRS)
Sandford, M. C.; Ricketts, R. H.; Cazier, F. W., Jr.
1980-01-01
A supercritical wing with an aspect ratio of 10.76 and with two trailing-edge oscillating control surfaces is described. The semispan wing is instrumented with 252 static orifices and 164 in situ dynamic-pressure gages for studying the effects of control-surface position and motion on steady- and unsteady-pressures at transonic speeds. Results from initial tests conducted in the Langley Transonic Dynamics Tunnel at two Reynolds numbers are presented in tabular form.
Verification of the Chesapeake Bay Model.
1981-12-01
points on the model. Each inflow control unit consists of a pressure regulator , a digital flow control valve, and a flowmeter (Fig- ure 8). A mechanical...spring-type pressure regulator ensures constant pressure to the digital flow control valve. Each digital valve contains eight solenoid valve actuators...FT) =0.798 EEOC 1DGS 2.78 EPOCH (DEGS) - 11. 84 3 DATA TAKEN: AC(0) = 0. 11 38 F T A (0)= 0. 1653 FT 28 MAR 1978 RANGE (FT) - 1.638 RANGE (FT
Quasi-Porous Plug With Vortex Chamber
NASA Technical Reports Server (NTRS)
Walsh, J. V.
1985-01-01
Pressure-letdown valve combines quasi-porous-plug and vortex-chamber in one controllable unit. Valve useful in fossil-energy plants for reducing pressures in such erosive two-phase process streams as steam/water, coal slurries, or combustion gases with entrained particles. Quasi-Porous Plug consists of plenums separated by perforated plates. Number or size of perforations increases with each succeeding stage to compensate for expansion. In Vortex Chamber, control flow varies to control swirl and therefore difference between inlet and outlet pressures.
Rapid Quench Cold-Seal Apparatus with Computer-Controlled Pressure and Temperature Cycling
NASA Astrophysics Data System (ADS)
Johnston, A.; Senkovich, D.
2007-12-01
We have constructed two computer-controlled, rapid quench, hydrothermal apparatuses that are ideal for experimentation on volcanological, geothermal, and ore deposit research problems. The devices can achieve maximum pressures of about 2 kbar and temperatures to 1100C, have the ability for experiments to be quenched very rapidly in a water-cooled environment, and are interfaced with computers which can control any regimen of pressure and/or temperature cycling that may be desired, accomplished via Lab-View software and data acquisition and motion control boards from National Instruments. The rapid quench aspects of the design were developed originally by Dr. Phil Ihinger and have subsequently been adopted by many labs around the world; a good summary description of these aspects of the equipment, and the use of filler-rods for controlling redox conditions in such equipment, are provided by Matthews et al. (2004, Am. Mineral., 88: 701-707). Our design has fixed Rene 41 pressure vessels, furnaces that are raised and lowered by computer controlled pneumatic cylinders and water cooling systems that are controlled by computer operated solenoid valves. The novel feature of our design is the pressure generation and control systems. We coupled the seal-ends of commercially available (HIP) pressure generators to shop-built linear actuators consisting of nearly frictionless ball lead screws within thick walled stainless steel housings. These in turn are driven by NEMA size 23 stepper motors coupled to 100:1 gear reduction units. The actuators require 21 revolutions to achieve their full stroke of 12.7 cm which displaces about 10 cc of fluid. Operating the motors at the relatively low resolution of 800 steps per revolution leads to about 132,000 steps per cm of travel of the pressure-generating piston, providing exceptionally high precision and excellent pressure control. Instantaneous decompression can be achieved by simply opening a valve while motor-controlled decompression from 2 kbar to 1 bar can occur over time spans ranging from about one minute to months. This equipment will find immediate use in studies of decompression- induced magmatic vesiculation and crystallization in sub-volcanic and volcanic conduit environments and decompression-induced precipitation of fracture-filling ore and silicate minerals in crustal hydrothermal environments.
Do agonistic motives matter more than anger? Three studies of cardiovascular risk in adolescents.
Ewart, Craig K; Elder, Gavin J; Smyth, Joshua M; Sliwinski, Martin J; Jorgensen, Randall S
2011-09-01
Three motivational profiles have been associated with recurring psychological stress in low-income youth and young adults: Striving to control others (agonistic striving), striving to control the self (transcendence striving), and not asserting control (dissipated striving). Agonistic striving has been associated with elevated ambulatory blood pressure during daily activities. Three studies tested the hypotheses that: (1) agonistic striving is associated with poor anger regulation, and (2) agonistic striving and poor anger regulation interactively elevate blood pressure. Motivational profiles, anger regulation, and ambulatory blood pressure were assessed in a multiethnic sample of 264 urban youth. (1) anger regulation/recovery during laboratory challenge; (2) anger/blood pressure during daily activities (48 hours). Replication of the profiles in distant cities showed they occur with similar frequency across differences of region, race, and gender. Analyses controlling for body size, race, and gender revealed that individuals with the agonistic striving profile had higher ambulatory pressure, especially during social encounters. They became more openly angry and aggressive when challenged but did not exhibit difficulty regulating anger in the laboratory, nor did they feel angrier during monitoring. However, individuals with the agonistic striving profile who did display poor anger regulation in the lab had the highest blood pressure; deficient self-regulatory capability amplified the positive association between agonistic striving and cardiovascular risk in both genders and all ethnic groups. Although anger is thought to increase cardiovascular risk, present findings suggest that anger and elevated blood pressure are coeffects of agonistic struggles to control others.
Effects of wet-cupping on blood pressure in hypertensive patients: a randomized controlled trial.
Aleyeidi, Nouran A; Aseri, Khaled S; Matbouli, Shadia M; Sulaiamani, Albaraa A; Kobeisy, Sumayyah A
2015-11-01
Although cupping remains a popular treatment modality worldwide, its efficacy for most diseases, including hypertension, has not been scientifically evaluated. We aimed to determine the efficacy of wet-cupping for high blood pressure, and the incidence of the procedure's side effects in the intervention group. This is a randomized controlled trial conducted in the General Practice Department at King Abdulaziz University Hospital, Jeddah, Saudi Arabia, between May 2013 and February 2014. There were two groups (40 participants each): intervention group undergoing wet-cupping (hijama) in addition to conventional hypertension treatment, and a control group undergoing only conventional hypertension treatment. Three wet-cupping sessions were performed every other day. The mean systolic and diastolic blood pressures were measured using a validated automatic sphygmomanometer. The follow-up period was 8 weeks. Wet-cupping provided an immediate reduction of systolic blood pressure. After 4 weeks of follow-up, the mean systolic blood pressure in the intervention group was 8.4 mmHg less than in the control group (P=0.046). After 8 weeks, there were no significant differences in blood pressures between the intervention and control groups. In this study, wet-cupping did not result in any serious side effects. Wet-cupping therapy is effective for reducing systolic blood pressure in hypertensive patients for up to 4 weeks, without serious side effects. Wet-cupping should be considered as a complementary hypertension treatment, and further studies are needed. ClinicalTrials.gov Identifier NCT01987583.
The pressor response to water drinking in humans : a sympathetic reflex?
NASA Technical Reports Server (NTRS)
Jordan, J.; Shannon, J. R.; Black, B. K.; Ali, Y.; Farley, M.; Costa, F.; Diedrich, A.; Robertson, R. M.; Biaggioni, I.; Robertson, D.
2000-01-01
BACKGROUND: Water drinking increases blood pressure profoundly in patients with autonomic failure and substantially in older control subjects. The mechanism that mediates this response is not known. METHODS AND RESULTS: We studied the effect of drinking tap water on seated blood pressure in 47 patients with severe autonomic failure (28 multiple system atrophy [MSA], 19 pure autonomic failure patients [PAF]). Eleven older controls and 8 young controls served as control group. We also studied the mechanisms that could increase blood pressure with water drinking. Systolic blood pressure increased profoundly with water drinking, reaching a maximum of 33+/-5 mm Hg in MSA and 37+/-7 in PAF mm Hg after 30 to 35 minutes. The pressor response was greater in patients with more retained sympathetic function and was almost completely abolished by trimethaphan infusion. Systolic blood pressure increased by 11+/-2.4 mm Hg in elderly but not in young controls. Plasma norepinephrine increased in both groups. Plasma renin activity, vasopressin, and blood volume did not change in any group. CONCLUSIONS: Water drinking significantly and rapidly raises sympathetic activity. Indeed, it raises plasma norepinephrine as much as such classic sympathetic stimuli as caffeine and nicotine. This effect profoundly increases blood pressure in autonomic failure patients, and this effect can be exploited to improve symptoms due to orthostatic hypotension. Water drinking also acutely raises blood pressure in older normal subjects. The pressor effect of oral water is an important yet unrecognized confounding factor in clinical studies of pressor agents and antihypertensive medications.
Racial differences in barriers to blood pressure control in a family practice setting.
Scott, Jonathan M; Spees, Colleen K; Taylor, Christopher A; Wexler, Randy
2010-10-01
Hypertension prevalence in the African American community is greater than in all other ethnic groups. Cultural perceptions of health and disease introduce barriers to providing effective care. The purpose of this study was to identify racial differences in the perceived causes of hypertension, current behaviors performed to control blood pressure, and perceived barriers to preventing or treating hypertension. A self-administered survey of patients seen for medical care in a primary care network was conducted. The survey was developed to measure perceptions of hypertension etiology and treatments. Data from African American (n = 69) and Caucasian (n = 218) respondents were used to assess racial differences in perceptions of blood pressure control. About half of respondents knew their current blood pressures. African American patients were significantly less likely to believe that hypertension was caused by a lack of exercise and obesity. Significantly more Caucasians were less likely to report cutting down on table salt and taking prescription medications for blood pressure control. Both African Americans and Caucasians believed that sodium reduction was the most easily changed behavior to control their blood pressure, while both groups identified weight loss as being the most difficult. Racial differences exist in the perceived causes and treatments of high blood pressure, indicating a need for further patient education. When treating and counseling patients, physicians and support staff members must be sensitive to racial diversity and strive to offer culturally relevant solutions, especially for behaviors perceived as most difficult to change.
Thermoelectric Control Of Temperatures Of Pressure Sensors
NASA Technical Reports Server (NTRS)
Burkett, Cecil G., Jr.; West, James W.; Hutchinson, Mark A.; Lawrence, Robert M.; Crum, James R.
1995-01-01
Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.
2016-10-01
testing as well as finite element simulation. Automation and control testing has been completed on a 5x5 array of bubble actuators to verify pressure...mechanical behavior at varying loads and internal pressures both by experimental testing as well as finite element simulation. Automation and control...A finite element (FE) model of the bubble actuator was developed in the commercial software ANSYS in order to determine the deformation of the
Micro X-ray CT Imaging of Sediments under Confining Pressure
NASA Astrophysics Data System (ADS)
Schindler, M.; Prasad, M.
2016-12-01
We developed a pressure and temperature control system for use inside the micro X-ray CT scanner Xradia 400. We succeeded in building a pressure vessel that can be pressurized to 34.5 MPa (5000 psi) while being transparent to X-rays. The setup can currently be cooled to -5°C and heated to 40°C. We were able to observe grain damage and porosity reduction due to applied confining pressure in clean quartz sand samples and quartz sand and bentonite samples. By comparing micro CT images at atmospheric pressure and 13.8 MPa (2000 psi) confining pressure, we observed compaction of the samples resulting in grain damage and fracturing of sediment grains (Figure 1). When the confining pressure was decreased some grains experienced further fracturing. The grain damage appears irreversible. Further fracturing of grains in pre-compacted sediment was observed upon repeated confining pressure cycling. We are currently working on feed-throughs for fluid lines and electric wiring to use ultrasonic transducers and pressure control in combination. Further we plan to include pore pressure in addition to confining pressure into the system. The pressure control system in combination with ultrasonic transducers will allow us to visually observe pore scale changes in rock samples while simultaneously identifying their influence on ultrasonic velocities. Such pore-scale changes are usually not taken into account by rock physics models and could help to identify why laboratory data diverges from theoretical models. Further, it is possible to compute compressibility from mCT images at different stress states by image correlation
NASA Technical Reports Server (NTRS)
Schunk, R. Gregory
2002-01-01
This paper presents the Modeling and Analysis of the Space Station Environment Control and Life Support System Pressure Control Pump Assembly (PCPA). The contents include: 1) Integrated PCPA/Manifold Analyses; 2) Manifold Performance Analysis; 3) PCPA Motor Heat Leak Study; and 4) Future Plans. This paper is presented in viewgraph form.
NASA Astrophysics Data System (ADS)
Cai, Le; Mao, Xiaobing; Ma, Zhexuan
2018-02-01
This study first constructed the nonlinear mathematical model of the high-pressure common rail (HPCR) system in the diesel engine. Then, the nonlinear state transformation was performed using the flow’s calculation and the standard state space equation was acquired. Based on sliding-mode variable structure control (SMVSC) theory, a sliding-mode controller for nonlinear systems was designed for achieving the control of common rail pressure and the diesel engine’s rotational speed. Finally, on the simulation platform of MATLAB, the designed nonlinear HPCR system was simulated. The simulation results demonstrate that sliding-mode variable structure control algorithm shows favorable control performances and overcome the shortcomings of traditional PID control in overshoot, parameter adjustment, system precision, adjustment time and ascending time.
Chen, Donna T; Ko, Tomohiro M; Allen, Ashleigh A; Bonnie, Richard J; Suratt, Colleen E; Appelbaum, Paul S; Nunes, Edward V; Friedmann, Peter D; Lee, Joshua D; Gordon, Michael S; McDonald, Ryan; Wilson, Donna; Boney, Tamara Y; Murphy, Sean M; O'Brien, Charles P
2018-04-01
Individuals must feel free to exert personal control over decisions regarding research participation. We present an examination of participants' perceived personal control over, as well as reported pressures and threats from others, influencing their decision to join a study assessing the effectiveness of extended-release naltrexone in preventing opioid dependence relapse. Most participants endorsed a strong sense of control over the decision; few reported pressures or threats. Although few in number, participants' brief narrative descriptions of the pressures and threats are illuminating and provide context for their perceptions of personal control. Based on this work, we propose a useful set of tools to help ascertain participants' sense of personal control in joining research.
Peristaltic pump-based low range pressure sensor calibration system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vinayakumar, K. B.; Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore 5600012; Naveen Kumar, G.
2015-11-15
Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressuremore » leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.« less
Shum, Kenny; Alperin, Peter; Shalnova, Svetlana; Boytsov, Sergey; Kontsevaya, Anna; Vigdorchik, Alexey; Guetz, Adam; Eriksson, Jennifer; Hughes, David
2014-01-01
Objectives Russia faces a high burden of cardiovascular disease. Prevalence of all cardiovascular risk factors, especially hypertension, is high. Elevated blood pressure is generally poorly controlled and medication usage is suboptimal. With a disease-model simulation, we forecast how various treatment programs aimed at increasing blood pressure control would affect cardiovascular outcomes. In addition, we investigated what additional benefit adding lipid control and smoking cessation to blood pressure control would generate in terms of reduced cardiovascular events. Finally, we estimated the direct health care costs saved by treating fewer cardiovascular events. Methods The Archimedes Model, a detailed computer model of human physiology, disease progression, and health care delivery was adapted to the Russian setting. Intervention scenarios of achieving systolic blood pressure control rates (defined as systolic blood pressure <140 mmHg) of 40% and 60% were simulated by modifying adherence rates of an antihypertensive medication combination and compared with current care (23.9% blood pressure control rate). Outcomes of major adverse cardiovascular events; cerebrovascular event (stroke), myocardial infarction, and cardiovascular death over a 10-year time horizon were reported. Direct health care costs of strokes and myocardial infarctions were derived from official Russian statistics and tariff lists. Results To achieve systolic blood pressure control rates of 40% and 60%, adherence rates to the antihypertensive treatment program were 29.4% and 65.9%. Cardiovascular death relative risk reductions were 13.2%, and 29.6%, respectively. For the current estimated 43,855,000-person Russian hypertensive population, each control-rate scenario resulted in an absolute reduction of 1.0 million and 2.4 million cardiovascular deaths, and a reduction of 1.2 million and 2.7 million stroke/myocardial infarction diagnoses, respectively. Averted direct costs from current care levels ($7.6 billion [in United States dollars]) were $1.1 billion and $2.6 billion, respectively. PMID:25141122
Spacecraft Maneuvering at the Sun/Earth-Moon L2 Libration Point
NASA Astrophysics Data System (ADS)
Shahid, Kamran
Spacecraft formation flying in the vicinity of the Sun/Earth-Moon libration points offers many promising possibilities for space exploration. The concept of formation flying involves the distribution of the functionality of a single spacecraft among several smaller, cooperative spacecraft. The libration points are locations relative to two large orbiting bodies where a third body with relatively small mass can remain stationary relative to the two larger bodies. The most significant perturbation experienced by a spacecraft at the libration point is effect of solar radiation pressure. This thesis presents the development of nonlinear control techniques for maneuvering control at the Sun-Earth/Moon L2 libration point. A new thruster based formation control technique is presented. We also consider a leader/follower formation architecture, and examine the station keeping control of the leader spacecraft and the formation control of the follower spacecraft using solar radiation pressure. Reference trajectories of the leader spacecraft, halo and Lissajous orbits, are determined using a numerical technique in order to take into account all major gravitational perturbations. The nonlinear controllers are developed based on Lyapunov analysis, including non-adaptive and adaptive designs. Thruster based and solar radiation pressure based control laws for spacecraft maneuvering at the Sun-Earth/Moon libration point are developed. Higher order sliding mode control is utilized to address the non-affine structure of the solar sail control inputs. The reduced input solar radiation pressure problem is properly addressed as an underactuated control problem. The development of adaptive control for solar sail equipped spacecraft is an innovation and represents and advancement in solar sailing control technology. Controller performance is evaluated in a high fidelity ephemeris model to reflect a realistic simulated space environment. The numerical results demonstrate the effectiveness of the proposed control techniques for spacecraft maneuvering using solar radiation pressure at the L2 libration point. Stationkeeping accuracies of 50m and formation maintenance accuracies of less than 1m are possible using solar radiation pressure at a sub-L2 libration point. The benefits of these control techniques include increasing libration point mission lifetimes and doubling payload mass fractions as compared to conventional propulsion methods.
UV absorption control of thin film growth
Biefeld, Robert M.; Hebner, Gregory A.; Killeen, Kevin P.; Zuhoski, Steven P.
1991-01-01
A system for monitoring and controlling the rate of growth of thin films in an atmosphere of reactant gases measures the UV absorbance of the atmosphere and calculates the partial pressure of the gases. The flow of reactant gases is controlled in response to the partial pressure.
Control system for an artificial heart
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1970-01-01
Inexpensive industrial pneumatic components are combined to produce control system to drive sac-type heart-assistance blood pump with controlled pulsatile pressure that makes pump rate of flow sensitive to venous /atrial/ pressure, while stroke is centered about set operating point and pump is synchronized with natural heart.
NASA Astrophysics Data System (ADS)
SanSoucie, M. P.; Rogers, J. R.; Kumar, V.; Rodriguez, J.; Xiao, X.; Matson, D. M.
2016-07-01
The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has recently added an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled in the range from approximately 10^{-28} {to} 10^{-9} bar, while in a vacuum atmosphere. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, has a PID-based current loop and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects on surface tension and viscosity by oxygen partial pressure in the surrounding environment and the melt dissolved oxygen content will be evaluated, and the results will be presented. The surface tension and viscosity will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension and viscosity will be measured using the oscillating droplet method.
Teuchmann, K; Totterdell, P; Parker, S K
1999-01-01
Experience sampling methodology was used to examine how work demands translate into acute changes in affective response and thence into chronic response. Seven accountants reported their reactions 3 times a day for 4 weeks on pocket computers. Aggregated analysis showed that mood and emotional exhaustion fluctuated in parallel with time pressure over time. Disaggregated time-series analysis confirmed the direct impact of high-demand periods on the perception of control, time pressure, and mood and the indirect impact on emotional exhaustion. A curvilinear relationship between time pressure and emotional exhaustion was shown. The relationships between work demands and emotional exhaustion changed between high-demand periods and normal working periods. The results suggest that enhancing perceived control may alleviate the negative effects of time pressure.
Hypothermia for Intracranial Hypertension after Traumatic Brain Injury.
Andrews, Peter J D; Sinclair, H Louise; Rodriguez, Aryelly; Harris, Bridget A; Battison, Claire G; Rhodes, Jonathan K J; Murray, Gordon D
2015-12-17
In patients with traumatic brain injury, hypothermia can reduce intracranial hypertension. The benefit of hypothermia on functional outcome is unclear. We randomly assigned adults with an intracranial pressure of more than 20 mm Hg despite stage 1 treatments (including mechanical ventilation and sedation management) to standard care (control group) or hypothermia (32 to 35°C) plus standard care. In the control group, stage 2 treatments (e.g., osmotherapy) were added as needed to control intracranial pressure. In the hypothermia group, stage 2 treatments were added only if hypothermia failed to control intracranial pressure. In both groups, stage 3 treatments (barbiturates and decompressive craniectomy) were used if all stage 2 treatments failed to control intracranial pressure. The primary outcome was the score on the Extended Glasgow Outcome Scale (GOS-E; range, 1 to 8, with lower scores indicating a worse functional outcome) at 6 months. The treatment effect was estimated with ordinal logistic regression adjusted for prespecified prognostic factors and expressed as a common odds ratio (with an odds ratio <1.0 favoring hypothermia). We enrolled 387 patients at 47 centers in 18 countries from November 2009 through October 2014, at which time recruitment was suspended owing to safety concerns. Stage 3 treatments were required to control intracranial pressure in 54% of the patients in the control group and in 44% of the patients in the hypothermia group. The adjusted common odds ratio for the GOS-E score was 1.53 (95% confidence interval, 1.02 to 2.30; P=0.04), indicating a worse outcome in the hypothermia group than in the control group. A favorable outcome (GOS-E score of 5 to 8, indicating moderate disability or good recovery) occurred in 26% of the patients in the hypothermia group and in 37% of the patients in the control group (P=0.03). In patients with an intracranial pressure of more than 20 mm Hg after traumatic brain injury, therapeutic hypothermia plus standard care to reduce intracranial pressure did not result in outcomes better than those with standard care alone. (Funded by the National Institute for Health Research Health Technology Assessment program; Current Controlled Trials number, ISRCTN34555414.).
NASA Astrophysics Data System (ADS)
Birkholzer, J. T.; Gonzalez-Nicolas, A.; Cihan, A.
2017-12-01
Industrial-scale injection of CO2 into the subsurface increases the fluid pressure in the reservoir, sometimes to the point that the resulting stress increases must be properly controlled to prevent potential damaging impacts such as fault activation, leakage through abandoned wells, or caprock fracturing. Brine extraction is one approach for managing formation pressure, effective stress, and plume movement in response to CO2 injection. However, the management of the extracted brine adds cost to the carbon capture and sequestration operations; therefore optimizing (minimizing) the extraction volume of brine is of great importance. In this study, we apply an adaptive management approach that optimizes extraction rates of brine for pressure control in an integrated optimization framework involving site monitoring, model calibration, and optimization. We investigate the optimization performance as affected by initial site characterization data and introduction of newly acquired data during the injection phase. More accurate initial reservoir characterization data reduce the risk of pressure buildup damage with better estimations of initial extraction rates, which results in better control of pressure during the overall injection time periods. Results also show that low frequencies of model calibration and optimization with the new data, especially at early injection periods, may lead to optimization problems, either that pressure buildup constraints are violated or excessively high extraction rates are proposed. These optimization problems can be eliminated if more frequent data collection and model calibration are conducted, especially at early injection time periods. Approaches such as adaptive pressure management may constitute an effective tool to manage pressure buildup under uncertain and unknown reservoir conditions by minimizing the brine extraction volumes while not exceeding critical pressure buildups of the reservoir.
System and method for continuous solids slurry depressurization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leininger, Thomas Frederick; Steele, Raymond Douglas; Cordes, Stephen Michael
A system includes a first pump having a first outlet and a first inlet, and a controller. The first pump is configured to continuously receive a flow of a slurry into the first outlet at a first pressure and to continuously discharge the flow of the slurry from the first inlet at a second pressure less than the first pressure. The controller is configured to control a first speed of the first pump against the flow of the slurry based at least in part on the first pressure, wherein the first speed of the first pump is configured to resistmore » a backflow of the slurry from the first outlet to the first inlet.« less
NASA Technical Reports Server (NTRS)
Flachbart, R. H.; Hastings, L. J.; Hedayat, A.; Nelson, S. L.; Tucker, S. P.
2007-01-01
Due to its high specific impulse and favorable thermal properties for storage, liquid methane (LCH4) is being considered as a candidate propellant for exploration architectures. In order to gain an -understanding of any unique considerations involving micro-gravity pressure control with LCH4, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the performance of a spray-bar thermodynamic vent system (TVS) with subcooled LCH4 and gaseous helium (GHe) pressurant. Thirteen days of testing were performed in November 2006, with total tank heat leak conditions of about 715 W and 420 W at a fill level of approximately 90%. The TVS system was used to subcool the LCH4 to a liquid saturation pressure of approximately 55.2 kPa before the tank was pressurized with GHe to a total pressure of 165.5 kPa. A total of 23 TVS cycles were completed. The TVS successfully controlled the ullage pressure within a prescribed control band but did not maintain a stable liquid saturation pressure. This was likely. due to a TVS design not optimized for this particular propellant and test conditions, and possibly due to a large artificially induced heat input directly into the liquid. The capability to reduce liquid saturation pressure as well as maintain it within a prescribed control band, demonstrated that the TVS could be used to seek and maintain a desired liquid inlet temperature for an engine (at a cost of propellant lost through the TVS vent). One special test was conducted at the conclusion of the planned test activities. Reduction of the tank ullage pressure by opening the Joule-Thomson valve (JT) without operating the pump was attempted. The JT remained open for over 9300 seconds, resulting in an ullage pressure reduction of 30 kPa. The special test demonstrated the feasibility of using the JT valve for limited ullage pressure reduction in the event of a pump failure.
Mistiaen, Patriek; Achterberg, Wilco; Ament, Andre; Halfens, Ruud; Huizinga, Janneke; Montgomery, Ken; Post, Henri; Francke, Anneke L
2008-01-07
Pressure ulcers are a major problem, especially in nursing home patients, although they are regarded as preventable and there are many pressure relieving methods and materials. One such pressure relieving material is the recently developed Australian Medical Sheepskin, which has been shown in two randomized controlled trials 12 to be an effective intervention in the prevention of sacral pressure ulcers in hospital patients. However, the use of sheepskins has been debated and in general discouraged by most pressure ulcer working groups and pressure ulcer guidelines, but these debates were based on old forms of sheepskins. Furthermore, nothing is yet known about the (cost-)effectiveness of the Australian Medical sheepskin in nursing home patients. The objective of this study is to assess the effects and costs of the use of the Australian Medical Sheepskin combined with usual care with regard to the prevention of sacral pressure ulcers in somatic nursing home patients, versus usual care only. In a multi-centre randomised controlled trial 750 patients admitted for a primarily somatic reason to one of the five participating nursing homes, and not having pressure ulcers on the sacrum at admission, will be randomized to either usual care only or usual care plus the use of the Australian Medical Sheepskin as an overlay on the mattress. Outcome measures are: incidence of sacral pressure ulcers in the first month after admission; sacrum pressure ulcer free days; costs; patient comfort; and ease of use. The skin of all the patients will be observed once a day from admission on for 30 days. Patient characteristics and pressure risk scores are assessed at admission and at day 30 after it. Additional to the empirical phase, systematic reviews will be performed in order to obtain data for economic weighting and modelling. The protocol is registered in the Controlled Trial Register as ISRCTN17553857.
Seol, Geun Hee; Lee, Yun Hee; Kang, Purum; You, Ji Hye; Park, Mira; Min, Sun Seek
2013-07-01
The aim of this study was to investigate the effect of inhalation of Salvia sclarea (clary sage; clary) or Lavandula angustifolia (lavender) essential oil vapors on autonomic nervous system activity in female patients with urinary incontinence undergoing urodynamic assessment. STUDY DESIGN, LOCATION, AND SUBJECTS: This study was a double-blind, randomized, controlled trial carried out in 34 female patients with urinary incontinence. The subjects were randomized to inhale lavender, clary, or almond (control) oil at concentrations of 5% (vol/vol) each. Systolic blood pressure, diastolic blood pressure, pulse rate, respiratory rate, and salivary cortisol were measured before and after inhalation of these odors for 60 minutes. The clary oil group experienced a significant decrease in systolic blood pressure compared with the control (p=0.048) and lavender oil (p=0.026) groups, a significant decrease in diastolic blood pressure compared with the lavender oil group (p=0.034) and a significant decrease in respiratory rate compared with the control group (p<0.001). In contrast, the lavender oil group tended to increase systolic and diastolic blood pressure compared with the control group. Compared with the control group, inhalation of lavender oil (p=0.045) and clary oil (p<0.001) resulted in statistically significant reductions in respiratory rate. These results suggest that lavender oil inhalation may be inappropriate in lowering stress during urodynamic examinations, despite its antistress effects, while clary oil inhalation may be useful in inducing relaxation in female urinary incontinence patients undergoing urodynamic assessments.
Lee, Yun Hee; Kang, Purum; You, Ji Hye; Park, Mira; Min, Sun Seek
2013-01-01
Abstract Objectives The aim of this study was to investigate the effect of inhalation of Salvia sclarea (clary sage; clary) or Lavandula angustifolia (lavender) essential oil vapors on autonomic nervous system activity in female patients with urinary incontinence undergoing urodynamic assessment. Study design, location, and subjects This study was a double-blind, randomized, controlled trial carried out in 34 female patients with urinary incontinence. Outcome measure The subjects were randomized to inhale lavender, clary, or almond (control) oil at concentrations of 5% (vol/vol) each. Systolic blood pressure, diastolic blood pressure, pulse rate, respiratory rate, and salivary cortisol were measured before and after inhalation of these odors for 60 minutes. Results The clary oil group experienced a significant decrease in systolic blood pressure compared with the control (p=0.048) and lavender oil (p=0.026) groups, a significant decrease in diastolic blood pressure compared with the lavender oil group (p=0.034) and a significant decrease in respiratory rate compared with the control group (p<0.001). In contrast, the lavender oil group tended to increase systolic and diastolic blood pressure compared with the control group. Compared with the control group, inhalation of lavender oil (p=0.045) and clary oil (p<0.001) resulted in statistically significant reductions in respiratory rate. Conclusions These results suggest that lavender oil inhalation may be inappropriate in lowering stress during urodynamic examinations, despite its antistress effects, while clary oil inhalation may be useful in inducing relaxation in female urinary incontinence patients undergoing urodynamic assessments. PMID:23360656
Tanabe, Natsumi; Takane, Koki; Yokoyama, Keitaro; Tanno, Yudo; Yamamoto, Izumi; Ohkido, Ichiro; Yokoo, Takashi
2014-09-17
Baroreflex failure syndrome is a rare disorder which causes labile blood pressure, headache, flushing, diaphoresis and emotional lability. It is caused by history of trauma or radiotherapy in the cervical legion, bilateral carotid-body tumor or resection of glossopharyngeal nerve. We experienced a case of hemodialysis patient who had difficulty in controlling blood pressure during dialysis because of his baroreflex failure syndrome and successfully controlled his blood pressure by adjusting dialysate temperature. We report a case of a 68-year-old CKD5 patient who had difficulty in hemodialysis treatment because of severe fluctuations in blood pressure with hypertensive attacks and hypotensive episodes which caused him a severe discomfort. His dialysis treatment was started in 2010 and since that time baroreflex failure syndrome has been suspected because of his clinical manifestations and history of radiotherapy in the cervical region for his lingual cancer in 1994. Baroreflex failure syndrome is diagnosed by symptoms and cold stressor test. We performed a cold stressor test on an experimental baroreflex failure syndrome mouse and induced a significant elevation of blood pressure. From this experimental finding of model mouse, we changed the patients dialysate temperature between 34-38° according to his change in blood pressure though 80-240 mmHg. From this attempt, his blood pressure was successfully controlled between 100-180 mmHg and he was able to continue hemodialysis without any discomfort. In our case, environmental stimulation such as temperature change modified the patients fluctuating blood pressure. Change of dialysate temperature could be an option for controlling the unstable blood pressure due to baroreflex failure syndrome.
Hypotensive effect of aqueous extract of jamu antiatherosclerosis in male rats
NASA Astrophysics Data System (ADS)
Tristantini, Dewi; Amelinda, Kelly
2018-02-01
For many years, Averrhoa carambola L leaves, Mimusops elengi Linn leaves and Curcuma xanthorrhiza Roxb are used empirically in Indonesian traditional medicine to treat hypertension. This study was conducted to investigate the hypotensive effect of Averrhoa carambola L leaves, Mimusops elengi Linn leaves, and Curcuma xanthorrhiza Roxb extract (Jamu Antiatherosclerosis) in hypertensive induced rats. The effect of aqueous extract of jamu antiatherosclerosis on diastolic and systolic blood pressure was determined in sodium chloride induced rats. Twenty-four male rats weighted 160-200 g were randomly divided into 6 groups of 4 rats. The groups are consisting of normal control (without treatment), positive control (induced and given captopril 1.35 mg / 200 g body weight of rats), negative control (induced and standard feed), dosage controls (induced and given the extract of jamu antiatherosclerosis) each group with 3 different doses. The composition is dose I (13.2 mg / 200 g body weight of rats), dose II (26.4 mg / 200 g body weight of rats ml) and dose III (52.8 mg / 200 g body weight of rats). Blood pressure were measured via non-invasive blood pressure. The blood pressure was decreased in all dose. However, dose III has the highest blood pressure reducing effect that is 29.42 mmHg or 25.14% for diastolic blood pressure and 34.58 mmHg or 22.03% for systolic blood pressure. This performance equals to 91.15% and 93.56% of captopril activity in decreasing diastolic and systolic blood pressure. The aqueous extract has blood pressure lowering property that can be used as antihypertension herbal medicine.
Patient-related barriers to hypertension control in a Nigerian population
Okwuonu, Chimezie Godswill; Ojimadu, Nnamdi Ezekiel; Okaka, Enajite Ibiene; Akemokwe, Fatai Momodu
2014-01-01
Background Hypertension control is a challenge globally. Barriers to optimal control exist at the patient, physician, and health system levels. Patient-related barriers in our environment are not clear. The aim of this study was to identify patient-related barriers to control of hypertension among adults with hypertension in a semiurban community in South-East Nigeria. Methods This was a cross-sectional descriptive study of patients with a diagnosis of hypertension and on antihypertensive medication. Results A total of 252 participants were included in the survey, and comprised 143 males (56.7%) and 109 females (43.3%). The mean age of the participants was 56.6±12.7 years, with a diagnosis of hypertension for a mean duration of 6.1±3.3 years. Among these patients, 32.9% had controlled blood pressure, while 39.3% and 27.8%, respectively, had stage 1 and stage 2 hypertension according to the Seventh Report of the Joint National Committee on Prevention, Detection and Evaluation of High Blood Pressure. Only 23.4% knew the consequences of poor blood pressure control and 64% were expecting a cure from treatment even when the cause of hypertension was not known. Furthermore, 68.7% showed low adherence to medication, the reported reasons for which included forgetfulness (61.2%), financial constraints (56.6%), high pill burden (22.5%), side effects of medication (17.3%), and low measured blood pressure (12.1%). Finally, knowledge and practice of the lifestyle modifications necessary for blood pressure control was inadequate among the participants. Conclusion Poor knowledge regarding hypertension, unrealistic expectations of treatment, poor adherence with medication, unawareness of lifestyle modification, and failure to apply these were identified as patient-related barriers to blood pressure control in this study. PMID:25061335
Rashidi, Zahra; Azadbakht, Mehri; Amini, Ali; Karimi, Isac
2014-01-01
This study examines the effects of hydrostatic pressure on in vitro maturation (IVM) of oocytes derived from in vitro grown follicles. In this experimental study, preantral follicles were isolated from 12-day-old female NMRI mice. Each follicle was cultured individually in Alpha Minimal Essential Medium (α-MEM) under mineral oil for 12 days. Then, follicles were induced for IVM and divided into two groups, control and experiment. In the experiment group follicles were subjected to 20 mmHg pressure for 30 minutes and cultured for 24-48 hours. We assessed for viability and IVM of the oocytes. The percentage of apoptosis in cumulus cells was determined by the TUNEL assay. A comparison between groups was made using the student's t test. The percentage of metaphase II oocytes (MII) increased in hydrostatic pressuretreated follicles compared to controls (p<0.05). Cumulus cell viability reduced in hydrostatic pressure-treated follicles compared to controls (p<0.05). Exposure of follicles to pressure increased apoptosis in cumulus cells compared to controls (p<0.05). Hydrostatic pressure, by inducing apoptosis in cumulus cells, participates in the cumulus oocyte coupled relationship with oocyte maturation.
Nelson, Joan M; Cook, Paul F; Ingram, Jennifer C
2014-02-01
To evaluate constructs from the theory of planned behavior (TPB, Ajzen 2002) - attitudes, sense of control, subjective norms and intentions - as predictors of accuracy in blood pressure monitoring. Despite numerous initiatives aimed at teaching blood pressure measurement techniques, many healthcare providers measure blood pressures incorrectly. Descriptive, cohort design. Medical assistants and licensed practical nurses were asked to complete a questionnaire on TPB variables. These nursing staff's patients had their blood pressures measured and completed a survey about techniques used to measure their blood pressure. We correlated nursing staff's responses on the TBP questionnaire with their intention to measure an accurate blood pressure and with the difference between their actual blood pressure measurement and a second measurement taken by a researcher immediately after the clinic visit. Patients' perceptions of MAs' and LPNs' blood pressure measurement techniques were examined descriptively. Perceived control and social norm predicted intention to measure an accurate blood pressure, with a negative relationship between knowledge and intention. Consistent with the TPB, intention was the only significant predictor of blood pressure measurement accuracy. Theory of planned behavior constructs predicted the healthcare providers' intention to measure blood pressure accurately and intention predicted the actual accuracy of systolic blood pressure measurement. However, participants' knowledge about blood pressure measurement had an unexpected negative relationship with their intentions. These findings have important implications for nursing education departments and organisations which traditionally invest significant time and effort in annual competency training focused on knowledge enhancement by staff. This study suggests that a better strategy might involve efforts to enhance providers' intention to change, particularly by changing social norms or increasing perceived control of the behaviour by nursing staff. © 2013 Blackwell Publishing Ltd.
Proportional assist ventilation system based on proportional solenoid valve control.
Lua, A C; Shi, K C; Chua, L P
2001-07-01
A new proportional assist ventilation (PAV) method using a proportional solenoid valve (PSV) to control air supply to patients suffering from respiratory disabilities, was studied. The outlet flow and pressure from the proportional solenoid valve at various air supply pressures were tested and proven to be suitable for pressure and flow control in a PAV system. In vitro tests using a breathing simulator, which has been proven to possess the general characteristics of human respiratory system in spontaneous breathing tests, were conducted and the results demonstrated the viability of this PAV system in normalizing the breathing patterns of patients with abnormally high resistances and elastances as well as neuromuscular weaknesses. With a back-up safety mechanism incorporated in the control program, pressure "run-away" can be effectively prevented and safe operation of the system can be guaranteed.
Solenoid Driven Pressure Valve System: Toward Versatile Fluidic Control in Paper Microfluidics.
Kim, Taehoon H; Hahn, Young Ki; Lee, Jungmin; van Noort, Danny; Kim, Minseok S
2018-02-20
As paper-based diagnostics has become predominantly driven by more advanced microfluidic technology, many of the research efforts are still focused on developing reliable and versatile fluidic control devices, apart from improving sensitivity and reproducibility. In this work, we introduce a novel and robust paper fluidic control system enabling versatile fluidic control. The system comprises a linear push-pull solenoid and an Arduino Uno microcontroller. The precisely controlled pressure exerted on the paper stops the flow. We first determined the stroke distance of the solenoid to obtain a constant pressure while examining the fluidic time delay as a function of the pressure. Results showed that strips of grade 1 chromatography paper had superior reproducibility in fluid transport. Next, we characterized the reproducibility of the fluidic velocity which depends on the type and grade of paper used. As such, we were able to control the flow velocity on the paper and also achieve a complete stop of flow with a pressure over 2.0 MPa. Notably, after the actuation of the pressure driven valve (PDV), the previously pressed area regained its original flow properties. This means that, even on a previously pressed area, multiple valve operations can be successfully conducted. To the best of our knowledge, this is the first demonstration of an active and repetitive valve operation in paper microfluidics. As a proof of concept, we have chosen to perform a multistep detection system in the form of an enzyme-linked immunosorbent assay with mouse IgG as the target analyte.
Choking under monitoring pressure: being watched by the experimenter reduces executive attention.
Belletier, Clément; Davranche, Karen; Tellier, Idriss S; Dumas, Florence; Vidal, Franck; Hasbroucq, Thierry; Huguet, Pascal
2015-10-01
Performing more poorly given one's skill level ("choking") is likely in situations that offer an incentive if a certain outcome is achieved (outcome pressure) or when one is being watched by others-especially when one's performance is being evaluated (monitoring pressure). According to the choking literature, outcome pressure is associated with reduced executive control of attention, whereas monitoring pressure is associated with increased, yet counterproductive, attention to skill processes. Here, we show the first evidence that monitoring pressure-being watched by the experimenter-may lead individuals with higher working memory to choke on a classic measure of executive control-just the task effect thought to result from outcome pressure. Not only does this finding help refine our understanding of the processes underlying choking under monitoring pressure, but it also leads to a new look at classic audience effects, with an important implication for experimental psychology.
Blood pressure in firefighters, police officers, and other emergency responders.
Kales, Stefanos N; Tsismenakis, Antonios J; Zhang, Chunbai; Soteriades, Elpidoforos S
2009-01-01
Elevated blood pressure is a major risk factor for cardiovascular morbidity and mortality. Increased risk begins in the prehypertensive range and increases further with higher pressures. The strenuous duties of emergency responders (firefighters, police officers, and emergency medical services (EMS) personnel) can interact with their personal risk profiles, including elevated blood pressure, to precipitate acute cardiovascular events. Approximately three-quarters of emergency responders have prehypertension or hypertension, a proportion which is expected to increase, based on the obesity epidemic. Elevated blood pressure is also inadequately controlled in these professionals and strongly linked to cardiovascular disease morbidity and mortality. Notably, the majority of incident cardiovascular disease events occur in responders who are initially prehypertensive or only mildly hypertensive and whose average premorbid blood pressures are in the range in which many physicians would hesitate to prescribe medications (140-146/88-92). Laws mandating public benefits for emergency responders with cardiovascular disease provide an additional rationale for aggressively controlling their blood pressure. This review provides a background on emergency responders, summarizes occupational risk factors for hypertension and the metabolic syndrome, their prevalence of elevated blood pressure, and evidence linking hypertension with adverse outcomes in these professions. Next, discrepancies between relatively outdated medical standards for emergency responders and current, evidence-based guidelines for blood pressure management in the general public are highlighted. Finally, a workplace-oriented approach for blood pressure control among emergency responders is proposed, based on the seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure.
Steptoe, A; Cropley, M; Griffith, J; Joekes, K
1999-11-01
To assess the influence of abdominal obesity and work stress (operationalised as low control over work) on ambulatory blood pressure on a working day and evening. 156 school teachers (58 men and 98 women) carried out ambulatory blood pressure and heart rate monitoring on a work day and evening. Cardiovascular activity was also measured under baseline conditions on another occasion, when body weight, height, waist and hip circumference were assessed. Perceived control over work was assessed by questionnaire, along with mental health, anger expression and social support. 126 participants repeated the protocol after 12 months. Waist/hip ratio was used as the index of abdominal obesity. Baseline blood pressure was positively associated with waist/hip ratio in men, but ambulatory blood pressure and heart rate were not independently related to waist/hip ratio or job control. However, blood pressure and heart rate recorded during the working day and evening were elevated in men with high waist/hip ratio who experienced low job control, independently of age and body weight. Effects for diastolic blood pressure and heart rate were replicated after 12 months. Body mass index was not related to blood pressure or heart rate during the day or evening after adjustment for age and waist circumference. Low job control was associated with poor psychological well-being, negative mood and lack of social support. The results are consistent with the hypothesis that abdominal obesity in men is characterised by a tendency towards heightened stress-induced physiological activation, but that this tendency will only be manifest in the presence of appropriate environmental challenges such as chronic work stress.
Influence of dental occlusion on postural control and plantar pressure distribution.
Scharnweber, Benjamin; Adjami, Frederic; Schuster, Gabriele; Kopp, Stefan; Natrup, Jörg; Erbe, Christina; Ohlendorf, Daniela
2017-11-01
The number of studies investigating correlations between the temporomandibular system and body posture, postural control or plantar pressure distribution is continuously increasing. If a connection can be found, it is often of minor influence or for only a single parameter. However, small subject groups are critical. This study was conducted to define correlations between dental parameters, postural control and plantar pressure distribution in healthy males. In this study, 87 male subjects with an average age of 25.23 ± 3.5 years (ranging from 18 to 35 years) were examined. Dental casts of the subjects were analyzed. Postural control and plantar pressure distribution were recorded by a force platform. Possible orthodontic and orthopedic factors of influence were determined by either an anamnesis or a questionnaire. All tests performed were randomized and repeated three times each for intercuspal position (ICP) and blocked occlusion (BO). For a statistical analysis of the results, non-parametric tests (Wilcoxon-Matched-Pairs-Test, Kruskall-Wallis-Test) were used. A revision of the results via Bonferroni-Holm correction was considered. ICP increases body sway in the frontal (p ≤ 0.01) and sagittal planes (p ≤ 0.03) compared to BO, whereas all other 29 correlations were independent of the occlusion position. For both of the ICP or BO cases, Angle-class, midline-displacement, crossbite, or orthodontic therapy were found to have no influence on postural control or plantar pressure distribution (p > 0.05). However, the contact time of the left foot decreased (p ≤ 0.001) while detecting the plantar pressure distribution in each position. Persistent dental parameters have no effect on postural sway. In addition, postural control and plantar pressure distribution have been found to be independent postural criteria.
van Anholt, R D; Sobotka, L; Meijer, E P; Heyman, H; Groen, H W; Topinková, E; van Leen, M; Schols, J M G A
2010-09-01
We investigated the potential of a high-protein, arginine- and micronutrient-enriched oral nutritional supplement (ONS) to improve healing of pressure ulcers in non-malnourished patients who would usually not be considered for extra nutritional support. Forty-three non-malnourished subjects with stage III or IV pressure ulcers were included in a multicountry, randomized, controlled, double-blind, parallel group trial. They were offered 200 mL of the specific ONS or a non-caloric control product three times per day, in addition to their regular diet and standard wound care, for a maximum of 8 wk. Results were compared with repeated-measures mixed models (RMMM), analysis of variance, or Fisher's exact tests for categorical parameters. Supplementation with the specific ONS accelerated pressure ulcer healing, indicated by a significantly different decrease in ulcer size compared with the control, over the period of 8 wk (P
Clinical application of diadenosine tetraphosphate (Ap4A:F-1500) for controlled hypotension.
Kikuta, Y; Ohiwa, E; Okada, K; Watanabe, A; Haruki, S
1999-01-01
In our animal study, it was revealed that diadenosine tetraphosphate (Ap4A:F-1500) has a dose-dependent hypotension effect of up to 60% decrease in mean arterial pressure compared to control value. Furthermore, in healthy male volunteers, the safety of Ap4A up to 4 mg.min-1 was confirmed. In patients who require surgical procedures under general anesthesia together with controlled hypotension, hypotension was induced by Ap4A in order to examine its hypotensive effect and modulating action on the blood pressure. Ten patients who required controlled hypotension and who were scheduled for elective surgery under general anesthesia were studied. Anesthesia was maintained with isoflurane (n = 7) or sevoflurane (n = 3) in oxygen-nitrous oxide. Controlled hypotension was induced by Ap4A administered at a rate of 10-20 micrograms.kg-1.min-1. The dose was adjusted at a maximum rate of 80 micrograms.kg-1.min-1 until the target blood pressure was achieved. Arterial blood pressure and heart rate were monitored. Arterial samples were drawn at 4 separate time points to measure the concentration of Ap4A in the plasma. The time required for attaining the target blood pressure after initiation of Ap4A infusion was about 16 min, and the time lapse between withdrawal of infusion to recovery of blood pressure was about 18 min. No reflex tachycardia was observed during infusion of Ap4A and no rebound hypertension was evident after withdrawal. The plasma Ap4A concentration increased in response to the acceleration rate of Ap4A administration with a tendency of augmented hypotensive effect. As it produces an excellent hypotensive effect together with a modulating action on blood pressure, Ap4A was assessed as useful in producing controlled hypotension.
Focus control system for stretched-membrane mirror module
Butler, B.L.; Beninga, K.J.
1991-05-21
A focus control system dynamically sets and controls the focal length of a reflective membrane supported between a perimeter frame. A rear membrane is also supported between the perimeter frame rearward and spaced apart from a back side of the reflective membrane. The space between the membranes defines a plenum space into which a mass of gas at a first pressure is inserted. The pressure differential between the first pressure and an external pressure, such as the atmospheric pressure, causes the reflective membrane to assume a first curvature relative to a reference plane associated with the perimeter frame. This curvature defines the focal length of the reflective membrane. The focal length is dynamically controlled by changing the volume of the plenum space, thereby changing the first pressure. The system can be used to change or maintain the pressure differential and hence the front membrane curvature. The plenum volume is changed by pushing or pulling on a central section of the rear membrane using a suitable actuator. Sensing means continuously sense the location of the reflective membrane relative to the reference plane. This sensed position is compared to a reference position, and a resulting error signal, comprising the difference between the sensed position and reference position, drives the actuator in a direction to minimize the difference. A vent value compensates for temperature changes or leaks in the closed volume by allowing the pressure differential to be adjusted as required to center the working range of the actuator about the desired focal length. 13 figures.
Focus control system for stretched-membrane mirror module
Butler, Barry L.; Beninga, Kelly J.
1991-01-01
A focus control system dynamically sets and controls the focal length of a reflective membrane supported between a perimeter frame. A rear membrane is also supported between the perimeter frame rearward and spaced apart from a back side of the reflective membrane. The space between the membranes defines a plenum space into which a mass of gas at a first pressure is inserted. The pressure differential between the first pressure and an external pressure, such as the atmospheric pressure, causes the reflective membrane to assume a first curvature relative to a reference plane associated with the perimeter frame. This curvature defines the focal length of the reflective membrane. The focal length is dynamically controlled by changing the volume of the plenum space, thereby changing the first pressure. The system can be used to change or maintain the pressure differential and hence the front membrane curvature. The plenum volume is changed by pushing or pulling on a central section of the rear membrane using a suitable actuator. Sensing means continuously sense the location of the reflective membrane relative to the reference plane. This sensed position is compared to a reference position, and a resulting error signal, comprising the difference between the sensed position and reference position, drives the actuator in a direction to minimize the difference. A vent value compensates for temperature changes or leaks in the closed volume by allowing the pressure differential to be adjusted as required to center the working range of the actuator about the desired focal length.
NIM gas controlled sodium heat pipe
NASA Astrophysics Data System (ADS)
Yan, X.; Zhang, J. T.; Merlone, A.; Duan, Y.; Wang, W.
2013-09-01
Gas controlled heat pipes (GCHPs) provide a uniform, stable and reproducible temperature zone to calibrate thermometers and thermocouples, and to realize defining fixed points using a calorimetric method. Therefore, to perform such investigations, a GCHP furnace using sodium as its working fluid was constructed at the National Institute of Metrology (NIM), China. Also, investigations into the thermal characteristics of the NIM gas controlled sodium heat pipe were carried out. The temperature stability over 5 hours was better than ±0.25 mK while controlling the pressure at 111250 Pa. The temperature uniformity within 14 cm from the bottom of the thermometer well was within 0.3 mK. While keeping the pressure stable at the same value, 17 temperature determinations were performed over 14 days, obtaining a temperature reproducibility of 1.27 mK. Additionally, the NIM gas controlled sodium heat pipe was compared with the sodium heat pipe produced by INRiM. The temperature in the INRiM sodium heat pipe operating at 111250 Pa was determined, obtaining a difference of 21 mK with respect to the NIM GCHP. This difference was attributed to sodium impurities, pressure controller capabilities and reproducibility, and instabilities of high temperature standard platinum resistance thermometers (HTSPRTs). Further investigations will be carried out on extending the pressure/temperature range and connecting both GCHPs to the same pressure line.
Calibratable solid-state pressure switch
NASA Technical Reports Server (NTRS)
1969-01-01
Pressure switch, incorporating a semiconductor light-detector coupled to an electrically controlled actuating unit, provides accurate and reliable switching over a broad range of pressures and environments.
Non-Intrusive Pressure/Multipurpose Sensor and Method
NASA Technical Reports Server (NTRS)
Smith, William C. (Inventor)
2001-01-01
Method and apparatus are provided for determining pressure using a non-intrusive sensor that is easily attachable to the plumbing of a pressurized system. A bent mode implementation and a hoop mode implementation of the invention are disclosed. Each of these implementations is able to nonintrusively measure pressure while fluid is flowing. As well, each implementation may be used to measure mass flow rate simultaneously with pressure. An ultra low noise control system is provided for making pressure measurements during gas flow. The control system includes two tunable digital bandpass filters with center frequencies that are responsive to a clock frequency. The clock frequency is divided by a factor of N to produce a driving vibrational signal for resonating a metal sensor section.
Comparison of Engine/Inlet Distortion Measurements with MEMS and ESP Pressure Sensors
NASA Technical Reports Server (NTRS)
Soto, Hector L.; Hernandez, Corey D.
2004-01-01
A study of active-flow control in a small-scale boundary layer ingestion inlet was conducted at the NASA Langley Basic Aerodynamic Research Tunnel (BART). Forty MEMS pressure sensors, in a rake style configuration, were used to examine both the mean (DC) and high frequency (AC) components of the total pressure across the inlet/engine interface plane. The mean component was acquired and used to calculate pressure distortion. The AC component was acquired separately, at a high sampling rate, and is used to study the unsteady effects of the active-flow control. An identical total pressure rake, utilizing an Electronically Scanned Pressure (ESP) system, was also used to calculate distortion; a comparison of the results obtained using the two rakes is presented.
[Clinical utility of home blood pressure monitoring in patients under treatment].
Bauk, L; Costa, H A; Caligiuri, S I
2015-01-01
A low number of patients who are treated with antihypertensive drugs achieve therapeutic goals. Home blood pressure monitoring is an excellent tool for studying this population. To determine the prevalence of patients with controlled and uncontrolled hypertension, as well as white-coat-effect and masked hypertension, and to evaluate the relationship with target organ damage in different groups. Blood pressure readings were performed simultaneously in the clinic and in the home using the same validated oscillometric equipment on 83 hypertensive patients on treatment with 2 or more antihypertensive drugs. They were then classified into 4 groups according to the cut-off values of the clinic and home blood pressure measurements. Left ventricular mass index, carotid intima media thickness, and microalbuminuria as markers of target organ damage, were also evaluated. Controlled blood pressure was present in 32.5%, 30.2% had sustained hypertension. The white coat effect was seen in 26.5%, while 10.8% were masked uncontrolled hypertension. Left ventricular mass index was higher in patients with no ambulatory control compared to controlled patients, and carotid IMT was also higher too in uncontrolled and white coat effect groups than controlled patients. More than one third of our patients who were treated with 2 or more drugs were not properly controlled, and they had significantly greater target organ damage than controlled patients. Copyright © 2014 SEHLELHA. Published by Elsevier Espana. All rights reserved.
Wind Tunnel Test of an RPV with Shape-Change Control Effector and Sensor Arrays
NASA Technical Reports Server (NTRS)
Raney, David L.; Cabell, Randolph H.; Sloan, Adam R.; Barnwell, William G.; Lion, S. Todd; Hautamaki, Bret A.
2004-01-01
A variety of novel control effector concepts have recently emerged that may enable new approaches to flight control. In particular, the potential exists to shift the composition of the typical aircraft control effector suite from a small number of high authority, specialized devices (rudder, aileron, elevator, flaps), toward larger numbers of smaller, less specialized, distributed device arrays. The concept envisions effector and sensor networks composed of relatively small high-bandwidth devices able to simultaneously perform a variety of control functions using feedback from disparate data sources. To investigate this concept, a remotely piloted flight vehicle has been equipped with an array of 24 trailing edge shape-change effectors and associated pressure measurements. The vehicle, called the Multifunctional Effector and Sensor Array (MESA) testbed, was recently tested in NASA Langley's 12-ft Low Speed wind tunnel to characterize its stability properties, control authorities, and distributed pressure sensitivities for use in a dynamic simulation prior to flight testing. Another objective was to implement and evaluate a scheme for actively controlling the spanwise pressure distribution using the shape-change array. This report describes the MESA testbed, design of the pressure distribution controller, and results of the wind tunnel test.
Active noise control using a steerable parametric array loudspeaker.
Tanaka, Nobuo; Tanaka, Motoki
2010-06-01
Arguably active noise control enables the sound suppression at the designated control points, while the sound pressure except the targeted locations is likely to augment. The reason is clear; a control source normally radiates the sound omnidirectionally. To cope with this problem, this paper introduces a parametric array loudspeaker (PAL) which produces a spatially focused sound beam due to the attribute of ultrasound used for carrier waves, thereby allowing one to suppress the sound pressure at the designated point without causing spillover in the whole sound field. First the fundamental characteristics of PAL are overviewed. The scattered pressure in the near field contributed by source strength of PAL is then described, which is needed for the design of an active noise control system. Furthermore, the optimal control law for minimizing the sound pressure at control points is derived, the control effect being investigated analytically and experimentally. With a view to tracking a moving target point, a steerable PAL based upon a phased array scheme is presented, with the result that the generation of a moving zone of quiet becomes possible without mechanically rotating the PAL. An experiment is finally conducted, demonstrating the validity of the proposed method.
The therapeutic effect of negative pressure in treating femoral head necrosis in rabbits.
Zhang, Yin-gang; Wang, Xuezhi; Yang, Zhi; Zhang, Hong; Liu, Miao; Qiu, Yushen; Guo, Xiong
2013-01-01
Because negative pressure can stimulate vascular proliferation, improve blood circulation and promote osteogenic differentiation of bone marrow stromal cells, we investigated the therapeutic effect of negative pressure on femoral head necrosis (FHN) in a rabbit model. Animals were divided into four groups (n = 60/group): [1] model control, [2] core decompression, [3] negative pressure and [4] normal control groups. Histological investigation revealed that at 4 and 8 weeks postoperatively, improvements were observed in trabecular bone shape, empty lacunae and numbers of bone marrow hematopoietic cells and fat cells in the negative pressure group compared to the core decompression group. At week 8, there were no significant differences between the negative pressure and normal control groups. Immunohistochemistry staining revealed higher expression of vascular endothelial growth factor (VEGF) and bone morphogenetic protein-2 (BMP-2) in the femoral heads in the negative pressure group compared with the core decompression group. Transmission electron microscopy revealed that cell organelles were further developed in the negative pressure group compared with the core decompression group. Microvascular ink staining revealed an increased number of bone marrow ink-stained blood vessels, a thicker vascular lumen and increased microvascular density in the negative pressure group relative to the core decompression group. Real-time polymerase chain reaction revealed that expression levels of both VEGF and BMP-2 were higher in the negative pressure group compared with the core decompression group. In summary, negative pressure has a therapeutic effect on FHN. This effect is superior to core decompression, indicating that negative pressure is a potentially valuable method for treating early FHN.
The Therapeutic Effect of Negative Pressure in Treating Femoral Head Necrosis in Rabbits
Zhang, Yin-gang; Wang, Xuezhi; Yang, Zhi; Zhang, Hong; Liu, Miao; Qiu, Yushen; Guo, Xiong
2013-01-01
Because negative pressure can stimulate vascular proliferation, improve blood circulation and promote osteogenic differentiation of bone marrow stromal cells, we investigated the therapeutic effect of negative pressure on femoral head necrosis (FHN) in a rabbit model. Animals were divided into four groups (n = 60/group): [1] model control, [2] core decompression, [3] negative pressure and [4] normal control groups. Histological investigation revealed that at 4 and 8 weeks postoperatively, improvements were observed in trabecular bone shape, empty lacunae and numbers of bone marrow hematopoietic cells and fat cells in the negative pressure group compared to the core decompression group. At week 8, there were no significant differences between the negative pressure and normal control groups. Immunohistochemistry staining revealed higher expression of vascular endothelial growth factor (VEGF) and bone morphogenetic protein-2 (BMP-2) in the femoral heads in the negative pressure group compared with the core decompression group. Transmission electron microscopy revealed that cell organelles were further developed in the negative pressure group compared with the core decompression group. Microvascular ink staining revealed an increased number of bone marrow ink-stained blood vessels, a thicker vascular lumen and increased microvascular density in the negative pressure group relative to the core decompression group. Real-time polymerase chain reaction revealed that expression levels of both VEGF and BMP-2 were higher in the negative pressure group compared with the core decompression group. In summary, negative pressure has a therapeutic effect on FHN. This effect is superior to core decompression, indicating that negative pressure is a potentially valuable method for treating early FHN. PMID:23383276
Best, Krista L; Desharnais, Guylaine; Boily, Jeanette; Miller, William C; Camp, Pat G
2012-11-16
Pressure ulcers pose significant negative individual consequences and financial burden on the healthcare system. Prolonged sitting in High Fowler's position (HF) is common clinical practice for older adults who spend extended periods of time in bed. While HF aids in digestion and respiration, being placed in a HF may increase perceived discomfort and risk of pressure ulcers due to increased pressure magnitude at the sacral and gluteal regions. It is likely that shearing forces could also contribute to risk of pressure ulcers in HF. The purpose of this study was to evaluate the effect of a low-tech and time-efficient Trunk Release Manuever (TRM) on sacral and gluteal pressure, trunk displacement and perceived discomfort in ambulatory older adults. A randomized controlled trial was used. We recruited community-living adults who were 60 years of age and older using posters, newspaper advertisements and word-of-mouth. Participants were randomly allocated to either the intervention or control group. The intervention group (n = 59) received the TRM, while the control group (n = 58) maintained the standard HF position. The TRM group had significantly lower mean (SD) PPI values post-intervention compared to the control group, 59.6 (30.7) mmHg and 79.9 (36.5) mmHg respectively (p = 0.002). There was also a significant difference in trunk displacement between the TRM and control groups, +3.2 mm and -5.8 mm respectively (p = 0.005). There were no significant differences in perceived discomfort between the groups. The TRM was effective for reducing pressure in the sacral and gluteal regions and for releasing the trunk at the point of contact between the skin and the support surface, but did not have an effect on perceived discomfort. The TRM is a simple method of repositioning which may have important clinical application for the prevention of pressure ulcers that may occur as a result of HF.
30 CFR 250.516 - Blowout prevention equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pressure rating of the BOP system and BOP system components shall exceed the expected surface pressure to which they may be subjected. If the expected surface pressure exceeds the rated working pressure of the...-control procedure that indicates how the annular preventer will be utilized, and the pressure limitations...
30 CFR 250.516 - Blowout prevention equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pressure rating of the BOP system and BOP system components shall exceed the expected surface pressure to which they may be subjected. If the expected surface pressure exceeds the rated working pressure of the...-control procedure that indicates how the annular preventer will be utilized, and the pressure limitations...
30 CFR 250.515 - Blowout prevention equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pressure rating of the BOP system and BOP system components shall exceed the expected surface pressure to which they may be subjected. If the expected surface pressure exceeds the rated working pressure of the...-control procedure that indicates how the annular preventer will be utilized, and the pressure limitations...
NASA Astrophysics Data System (ADS)
Kim, Hunmo
In the brake systems, it is important to reduce the rear brake pressure in order to secure the safety of the vehicle in braking. So, there was some research that reduced and controlled the rear brake pressure exactly like a L. S. P. V and a E. L. S. P. V. However, the previous research has some weaknesses: the L. S. P. V is a mechanical system and its brake efficiency is lower than the efficiency of E. L. S. P. V. But, the cost of E. L. S. P. V is very higher so its application to the vehicle is very difficult. Additionally, when a fail appears in the circuit which controls the valves, the fail results in some wrong operation of the valves. But, the previous researchers didn't take the effect of fail into account. Hence, the efficiency of them is low and the safety of the vehicle is not confirmed. So, in this paper we develop a new economical pressure modulator that exactly controls brake pressure and confirms the safety of the vehicle in any case using a direct adaptive fuzzy controller.
Design and develop speed/pressure regulator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hasanul Basher, A.M.
1993-09-01
The Physics Division at Oak Ridge National Laboratory has several recirculating water cooling systems. One of them supplies deionized water at 150 psi, which is mainly used for cooling magnet windings at the Oak Ridge Isochronous Cyclotron (ORIC). The system has three 125-hp water pumps, each of which is capable of supplying water at the rate of 1000 gpm. One of the major requirements of this water supply system is that the supply pressure must be kept constant. An adjustable-frequency speed controller was recently installed to control the speed of one of the pump motors. A servo-system was provided withmore » the adjustable-frequency controller for regulating motor speed and, subsequently, the water pressure. After unsuccessful attempts to operate the servo, it was concluded that the regulator may not work for the existing system. Prior to installation of the variable-frequency controller, pressure regulation was accomplished with a pneumatically controlled load by-pass valve. To maintain constant pressure in the system, it is necessary to run always at full load, even if full load is not on the system. Hence, there is a waste of energy when full load is not connected to the system. So, designing and implementing one regulator that works at any load condition has become necessary. This report discusses the design of such a pressure regulator.« less
Karvellas, Constantine J; Fix, Oren K; Battenhouse, Holly; Durkalski, Valerie; Sanders, Corron; Lee, William M
2014-05-01
To determine if intracranial pressure monitor placement in patients with acute liver failure is associated with significant clinical outcomes. Retrospective multicenter cohort study. Academic liver transplant centers comprising the U.S. Acute Liver Failure Study Group. Adult critically ill patients with acute liver failure presenting with grade III/IV hepatic encephalopathy (n = 629) prospectively enrolled between March 2004 and August 2011. Intracranial pressure monitored (n = 140) versus nonmonitored controls (n = 489). Intracranial pressure monitored patients were younger than controls (35 vs 43 yr, p < 0.001) and more likely to be on renal replacement therapy (52% vs 38%, p = 0.003). Of 87 intracranial pressure monitored patients with detailed information, 44 (51%) had evidence of intracranial hypertension (intracranial pressure > 25 mm Hg) and overall 21-day mortality was higher in patients with intracranial hypertension (43% vs 23%, p = 0.05). During the first 7 days, intracranial pressure monitored patients received more intracranial hypertension-directed therapies (mannitol, 56% vs 21%; hypertonic saline, 14% vs 7%; hypothermia, 24% vs 10%; p < 0.03 for each). Forty-one percent of intracranial pressure monitored patients received liver transplant (vs 18% controls; p < 0.001). Overall 21-day mortality was similar (intracranial pressure monitored 33% vs controls 38%, p = 0.24). Where data were available, hemorrhagic complications were rare in intracranial pressure monitored patients (4 of 56 [7%]; three died). When stratifying by acetaminophen status and adjusting for confounders, intracranial pressure monitor placement did not impact 21-day mortality in acetaminophen patients (p = 0.89). However, intracranial pressure monitor was associated with increased 21-day mortality in nonacetaminophen patients (odds ratio, ~ 3.04; p = 0.014). In intracranial pressure monitored patients with acute liver failure, intracranial hypertension is commonly observed. The use of intracranial pressure monitor in acetaminophen acute liver failure did not confer a significant 21-day mortality benefit, whereas in nonacetaminophen acute liver failure, it may be associated with worse outcomes. Hemorrhagic complications from intracranial pressure monitor placement were uncommon and cannot account for mortality trends. Although our results cannot conclusively confirm or refute the utility of intracranial pressure monitoring in patients with acute liver failure, patient selection and ancillary assessments of cerebral blood flow likely have a significant role. Prospective studies would be required to conclusively account for confounding by illness severity and transplant.
NASA Technical Reports Server (NTRS)
Mccain, W. E.
1982-01-01
The results of a comparative study using the unsteady aerodynamic lifting surface theory, known as the Doublet Lattice method, and experimental subsonic steady- and unsteady-pressure measurements, are presented for a high-aspect-ratio supercritical wing model. Comparisons of pressure distributions due to wing angle of attack and control-surface deflections were made. In general, good correlation existed between experimental and theoretical data over most of the wing planform. The more significant deviations found between experimental and theoretical data were in the vicinity of control surfaces for both static and oscillatory control-surface deflections.
Plantar pressure asymmetry and risk of stress injuries in the foot of young soccer players.
Azevedo, Renato R; da Rocha, Emmanuel S; Franco, Pedro S; Carpes, Felipe P
2017-03-01
Asymmetries in the magnitude of plantar pressure are considered a risk factor for stress fracture of the fifth metatarsal in soccer athletes. To investigate the presence of plantar pressure asymmetries among young soccer athletes. Observational. Laboratory. Thirty young adolescents divided into a soccer player group (n = 15) or a matched control group (n = 15). Mean plantar pressure was determined for seven different regions of the foot. Data were compared between the preferred and non-preferred foot, and between the groups, during barefoot standing on a pressure mat system. Higher pressure was found in the hallux, 5th metatarsal and medial rearfoot of the non-preferred foot in the young soccer players. These asymmetries were not observed in the control group. Magnitudes of plantar pressure did not differ between the groups. Young soccer players present asymmetries in plantar pressure in the hallux, 5th metatarsal and medial rearfoot, with higher pressure observed in the non-preferred foot. Copyright © 2016 Elsevier Ltd. All rights reserved.
Differential pressure pin discharge apparatus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oakley, D.J.
Disclosed is a discharge assembly for allowing elongate pins to be discharged from an area of relatively low pressure to an area of relatively greater pressure. The discharge assembly includes a duck valve having a lip piece made of flexible material. The flexible lip piece responds to a fluctuating pressure created downstream by an aspirator. The aspirator reduces the downstream pressure sensed by the duck valve when the discharge assembly is in the open position. This allows elongate pins to be moved through the duck valve with no backflow because the aspirator pressure is less than the pressure in themore » low pressure area from which the pins originate. Closure of the assembly causes the aspirator static pressure to force the flexible duck valve lip piece into a tightly sealed position also preventing backflow. The discharge assembly can be easily controlled using a single control valve which blocks the flow of aspirator gas and closes the pins passageway extending through the assembly.« less
Controlling Gas-Flow Mass Ratios
NASA Technical Reports Server (NTRS)
Morris, Brian G.
1990-01-01
Proposed system automatically controls proportions of gases flowing in supply lines. Conceived for control of oxidizer-to-fuel ratio in new gaseous-propellant rocket engines. Gas-flow control system measures temperatures and pressures at various points. From data, calculates control voltages for electronic pressure regulators for oxygen and hydrogen. System includes commercially available components. Applicable to control of mass ratios in such gaseous industrial processes as chemical-vapor depostion of semiconductor materials and in automotive engines operating on compressed natural gas.
An electronic scanner of pressure for wind tunnel models
NASA Technical Reports Server (NTRS)
Kauffman, Ronald C.; Coe, Charles F.
1986-01-01
An electronic scanner of pressure (ESOP) has been developed by NASA Ames Research Center for installation in wind tunnel models. An ESOP system consists of up to 20 pressure modules (PMs), each with 48 pressure transducers and a heater, an analog-to-digital (A/D) converter module, a microprocessor, a data controller, a monitor unit, a control and processing unit, and a heater controller. The PMs and the A/D converter module are sized to be installed in the models tested in the Ames Aerodynamics Division wind tunnels. A unique feature of the pressure module is the lack of moving parts such as a pneumatic switch used in other systems for in situ calibrations. This paper describes the ESOP system and the results of the initial testing of the system. The initial results indicate the system meets the original design goal of 0.15 percent accuracy.
Effects of aromatherapy massage on blood pressure and lipid profile in korean climacteric women.
Hur, Myung-Haeng; Oh, Heeyoung; Lee, Myeong Soo; Kim, Chan; Choi, Ae-Na; Shin, Gil-Ran
2007-09-01
This study investigated the effects of aromatherapy massage on the lipid profile and blood pressure in Korean climacteric women. A wait-listed control group, pretest-posttest design was used. The subjects comprised 58 climacteric women: 30 in the experimental group and 28 in the control group. Aromatherapy massage using lavender, rose geranium, rose, and jasmine was given to the experimental group only. Each massage session lasted 30 minutes, and was performed once weekly for two 8-week periods with self abdominal daily massage at home. The intervention produced significant differences in the systolic blood pressure compare to pretreatment and significant differences in systolic and diastolic blood pressures at posttreatment between the two groups. These results suggest that aromatherapy massage may exert positive effects on blood pressure. However, more objective, clinical measures should be applied in a future study with a randomized placebo-controlled design.
Distribution of Blood Pressure Data from People Living Near AN Airport
NASA Astrophysics Data System (ADS)
GOTO, K.; KANEKO, T.
2002-02-01
We observed blood pressure in general health examination data around a city airport and compared the data with those from a calm suburban area of the city. Information was also collected on the short-term history of medication and lifestyle including smoking, drinking and eating salty foods. This cross-sectional study on 469 women showed that systolic and diastolic blood pressure was not associated with aircraft noise levels in the area, even after controlling for variables regarding anti-hypertension treatment and lifestyle factors. A comparative study on 469 women from an area around an airport and 1177 women from a suburban control area showed no significant differences between blood pressure and other medical tests controlling for the variables of medication and lifestyle. Changes in blood pressure after 8 years were observed in 183 women around the airport. No significant differences among three zones with different levels of aircraft noise were found.
Automated Cryocooler Monitor and Control System Software
NASA Technical Reports Server (NTRS)
Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad
2011-01-01
This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.
Marcos, Begonya; Aymerich, Teresa; Monfort, Josep M; Garriga, Margarita
2008-02-01
The efficiency of combining high-pressure processing (HPP) and active packaging technologies to control Listeria monocytogenes growth during the shelf life of artificially inoculated cooked ham was assessed. Three lots of cooked ham were prepared: control, packaging with alginate films, and packaging with antimicrobial alginate films containing enterocins. After packaging, half of the samples were pressurized. Sliced cooked ham stored at 6 degrees C experienced a quick growth of L. monocytogenes. Both antimicrobial packaging and pressurization delayed the growth of the pathogen. However, at 6 degrees C the combination of antimicrobial packaging and HPP was necessary to achieve a reduction of inoculated levels without recovery during 60 days of storage. Further storage at 6 degrees C of pressurized antimicrobial packed cooked ham resulted in L. monocytogenes levels below the detection limit (day 90). On the other hand, storage at 1 degrees C controlled the growth of the pathogen until day 39 in non-pressurized ham, while antimicrobial packaging and storage at 1 degrees C exerted a bacteriostatic effect for 60 days. All HPP lots stored at 1 degrees C led to counts <100CFU/g at day 60. Similar results were observed when combining both technologies. After a cold chain break no growth of L. monocytogenes was observed in pressurized ham packed with antimicrobial films, showing the efficiency of combining both technologies.
NASA Technical Reports Server (NTRS)
Sandford, M. C.; Ricketts, R. H.; Watson, J. J.
1981-01-01
A high aspect ratio supercritical wing with oscillating control surfaces is described. The semispan wing model was instrumented with 252 static orifices and 164 in situ dynamic pressure gases for studying the effects of control surface position and sinusoidal motion on steady and unsteady pressures. Data from the present test (this is the second in a series of tests on this model) were obtained in the Langley Transonic Dynamics Tunnel at Mach numbers of 0.60 and 0.78 and are presented in tabular form.
NASA Technical Reports Server (NTRS)
Foote, C. H.
1980-01-01
Results from the altitude testing of a P sub T/P sub S noseboom probe on the F100 engine are discused. The results are consistent with sea level test results. The F100 engine altitude test verified automatic downmatch with the engine pressure ratio control, and backup control inlet case static pressure demonstrated sufficient accuracy for backup control fuel flow scheduling. The production P6 probe measured Station 6 pressures accurately for both undistorted and distorted inlet airflows.
Progress toward hydrogen peroxide micropulsion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitehead, J C; Dittman, M D; Ledebuhr, A G
1999-07-08
A new self-pressurizing propulsion system has liquid thrusters and gas jet attitude control without heavy gas storage vessels. A pump boosts the pressure of a small fraction of the hydrogen peroxide, so that reacted propellant can controllably pressurize its own source tank. The warm decomposition gas also powers the pump and is supplied to the attitude control jets. The system has been incorporated into a prototype microsatellite for terrestrial maneuvering tests. Additional progress includes preliminary testing of a bipropellant thruster, and storage of unstabilized hydrogen peroxide in small sealed tanks.
Process and control systems for composites manufacturing
NASA Technical Reports Server (NTRS)
Tsiang, T. H.; Wanamaker, John L.
1992-01-01
A precise control of composite material processing would not only improve part quality, but it would also directly reduce the overall manufacturing cost. The development and incorporation of sensors will help to generate real-time information for material processing relationships and equipment characteristics. In the present work, the thermocouple, pressure transducer, and dielectrometer technologies were investigated. The monitoring sensors were integrated with the computerized control system in three non-autoclave fabrication techniques: hot-press, self contained tool (self heating and pressurizing), and pressure vessel). The sensors were implemented in the parts and tools.
Internal voltage control of hydrogen-oxygen fuel cells: Feasibility study
NASA Technical Reports Server (NTRS)
Prokopius, P. R.
1975-01-01
An experimental study was conducted to assess the feasibility of internal voltage regulation of fuel cell systems. Two methods were tested. In one, reactant partial pressure was used as the voltage control parameter and in the other reactant total pressure was used for control. Both techniques were breadboarded and tested on a single alkaline-electrolyte fuel cell. Both methods were found to be possible forms of regulation, however, of the two the total pressure technique would be more efficient, simpler to apply and would provide better transient characteristics.
Sliding pressure control valve for pneumatic hammer drill
Polsky, Yarom [Albuquerque, NM
2011-08-30
A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.
Bayes to the Rescue: Continuous Positive Airway Pressure Has Less Mortality Than High-Flow Oxygen.
Modesto I Alapont, Vicent; Khemani, Robinder G; Medina, Alberto; Del Villar Guerra, Pablo; Molina Cambra, Alfred
2017-02-01
The merits of high-flow nasal cannula oxygen versus bubble continuous positive airway pressure are debated in children with pneumonia, with suggestions that randomized controlled trials are needed. In light of a previous randomized controlled trial showing a trend for lower mortality with bubble continuous positive airway pressure, we sought to determine the probability that a new randomized controlled trial would find high-flow nasal cannula oxygen superior to bubble continuous positive airway pressure through a "robust" Bayesian analysis. Sample data were extracted from the trial by Chisti et al, and requisite to "robust" Bayesian analysis, we specified three prior distributions to represent clinically meaningful assumptions. These priors (reference, pessimistic, and optimistic) were used to generate three scenarios to represent the range of possible hypotheses. 1) "Reference": we believe bubble continuous positive airway pressure and high-flow nasal cannula oxygen are equally effective with the same uninformative reference priors; 2) "Sceptic on high-flow nasal cannula oxygen": we believe that bubble continuous positive airway pressure is better than high-flow nasal cannula oxygen (bubble continuous positive airway pressure has an optimistic prior and high-flow nasal cannula oxygen has a pessimistic prior); and 3) "Enthusiastic on high-flow nasal cannula oxygen": we believe that high-flow nasal cannula oxygen is better than bubble continuous positive airway pressure (high-flow nasal cannula oxygen has an optimistic prior and bubble continuous positive airway pressure has a pessimistic prior). Finally, posterior empiric Bayesian distributions were obtained through 100,000 Markov Chain Monte Carlo simulations. In all three scenarios, there was a high probability for more death from high-flow nasal cannula oxygen compared with bubble continuous positive airway pressure (reference, 0.98; sceptic on high-flow nasal cannula oxygen, 0.982; enthusiastic on high-flow nasal cannula oxygen, 0.742). The posterior 95% credible interval on the difference in mortality identified a future randomized controlled trial would be extremely unlikely to find a mortality benefit for high-flow nasal cannula oxygen over bubble continuous positive airway pressure, regardless of the scenario. Interpreting these findings using the "range of practical equivalence" framework would recommend rejecting the hypothesis that high-flow nasal cannula oxygen is superior to bubble continuous positive airway pressure for these children. For children younger than 5 years with pneumonia, high-flow nasal cannula oxygen has higher mortality than bubble continuous positive airway pressure. A future randomized controlled trial in this population is unlikely to find high-flow nasal cannula oxygen superior to bubble continuous positive airway pressure.
NASA Technical Reports Server (NTRS)
Taylor, B.; Brissette, R.; Humphrey, A.; Morris, J.; Luger, J.; Swift, W.
1978-01-01
The HEAO-B Gas Control System consists of a high pressure gas storage supply together with distribution and regulation assemblies and their associated electronics for management of gas required for HEAO-B X-ray counter experiments. The Gas Control System replenishes a gas mixture (82 percent argon, 12.3 percent carbon dioxide, 5.7 percent xenon) in the counter volumes which is lost by: diffusion through controlled leakage plugs, diffusion through counter windows, and consumption resulting from periodic purges. The gas density in each counter volume is maintained constant to within 0.25 percent by comparison with a sealed reference volume. The system is fully redundant, capable of operating at atmospheric pressure as well as in a vacuum, contains interlocks which shut down gas flow in the event of either leakage or excessive pressure, and is able to shut down counter high voltage if counter pressure is abnormally low. The system is electronically controlled by ground command and self-sustaining in orbit for a period of at least one year.
Design development and test: Two-gas atmosphere control subsystem
NASA Technical Reports Server (NTRS)
Jackson, J. K.
1974-01-01
An atmosphere control subsystem (ACS) was developed for NASA-IBJSC which is designed to measure the major atmospheric constituents in the manned cabin of the space shuttle orbiter and control the addition of oxygen and nitrogen to maintain the partial pressures of these gases within very close limits. The ACS includes a mass spectrometer sensor (MSS) which analyzes the atmosphere of a shuttle vehicle pressurized cabin, and an electronic control assembly (ECA). The MSS was built and tested to meet the requirements for flight equipment for the M-171 Metabolic Analyzer experiment for the Skylab flight program. The instrument analyzes an atmospheric gas sample and produces continuous 0-5 vdc analog signals proportional to the partial pressures of H2, O2, N2, H2O, CO2 and total hydrocarbons having a m/e ratio between 50 and 120. It accepts signals from the MSS proportional to the partial pressures of N2 and O2 and controls the supply of these gases to the closed cabin.
Liao, I-Chen; Chen, Shiah-Lian; Wang, Mei-Yeh; Tsai, Pei-Shan
2016-01-01
Massage may help reduce blood pressure; previous studies on the effect of massage on blood pressure have presented conflicting findings. In addition, no systematic review is available. The aim of this study was to evaluate the evidence concerning the effect of massage on blood pressure in patients with hypertension or prehypertension. A search was performed on electronic database records up to October 31, 2013, based on the following medical subject headings or keywords: hypertension, massage, chiropractic, manipulation, and blood pressure. The methodological quality of randomized controlled trials was assessed based on the Cochrane collaboration tool. A meta-analysis was performed to evaluate the effect of massage on hypertension. The study selection, data extraction, and validation were performed independently by 2 reviewers. Nine randomized controlled trials met our inclusion criteria. The results of this study show that massage contributes to significantly enhanced reduction in both systolic blood pressure (SBP) (mean difference, -7.39 mm Hg) and diastolic blood pressure (DBP) (mean difference, -5.04 mm Hg) as compared with control treatments in patients with hypertension and prehypertension. The effect size (Hedges g) for SBP and DBP was -0.728 (95% confidence interval, -1.182 to -0.274; P = .002) and -0.334 (95% confidence interval, -0.560 to -0.107; P = .004), respectively. This systematic review found a medium effect of massage on SBP and a small effect on DBP in patients with hypertension or prehypertension. High-quality randomized controlled trials are urgently required to confirm these results, although the findings of this study can be used to guide future research.
Do Agonistic Motives Matter More Than Anger? Three Studies of Cardiovascular Risk in Adolescents
Ewart, Craig K.; Elder, Gavin J.; Smyth, Joshua M.; Sliwinski, Martin J.; Jorgensen, Randall S.
2011-01-01
Objective Three motivational profiles have been associated with recurring psychological stress in low-income youth and young adults: Striving to control others (agonistic striving), striving to control the self (transcendence striving), and not asserting control (dissipated striving); Agonistic Striving has been associated with elevated ambulatory blood pressure during daily activities. Three studies tested the hypotheses that: (1) Agonistic Striving is associated with poor anger regulation, and (2) Agonistic Striving and poor anger regulation interactively elevate blood pressure. Design Motivational profiles, anger regulation, and ambulatory blood pressure were assessed in a multiethnic sample of 264 urban youth. Main outcome measures (1) Anger regulation/recovery during laboratory challenge; (2) anger / blood pressure during daily activities (48 hours). Results and conclusion Replication of the profiles in distant cities showed they occur with similar frequency across differences of region, race, and gender. Analyses controlling for body size, race, and gender revealed that individuals with the Agonistic Striving profile had higher ambulatory pressure, especially during social encounters. They became more openly angry and aggressive when challenged, but did not exhibit difficulty regulating anger in the laboratory, nor did they feel more angry during monitoring. However, individuals with the Agonistic Striving profile who did display poor anger regulation in the lab had the highest blood pressure; deficient self-regulatory capability amplified the positive association between Agonistic Striving and cardiovascular risk in both genders and all ethnic groups. Although anger is thought to increase cardiovascular risk, present findings suggest that anger and elevated blood pressure are co-effects of agonistic struggles to control others. PMID:21534673
Persistent Currents in a Rotating Superleak Partially Filled with Superfluid Helium.
1982-12-01
the difference in pressure of the helium bath Po and the reduced vapor pressure in the cell P. In the region from 1.0 to 0.1 the log Po-P has been seen...easily measurable quantities of temperature, T, the helium bath pressure, Po, and the cell pressure P to the film thickness d. Alpha is a measure of the...rotation is controlled by a motor and power supply. The temperature is controlled by the pumping rate and a feedback heater in the helium bath and -maybe
The CF6 engine performance improvement
NASA Technical Reports Server (NTRS)
Fasching, W. A.
1982-01-01
As part of the NASA-sponsored Engine Component Improvement (ECI) Program, a feasibility analysis of performance improvement and retention concepts for the CF6-6 and CF6-50 engines was conducted and seven concepts were identified for development and ground testing: new fan, new front mount, high pressure turbine aerodynamic performance improvement, high pressure turbine roundness, high pressure turbine active clearance control, low pressure turbine active clearance control, and short core exhaust nozzle. The development work and ground testing are summarized, and the major test results and an enomic analysis for each concept are presented.
Bondonno, Catherine P; Yang, Xingbin; Croft, Kevin D; Considine, Michael J; Ward, Natalie C; Rich, Lisa; Puddey, Ian B; Swinny, Ewald; Mubarak, Aidilla; Hodgson, Jonathan M
2012-01-01
Flavonoids and nitrates in fruits and vegetables may protect against cardiovascular disease. Dietary flavonoids and nitrates can augment nitric oxide status via distinct pathways, which may improve endothelial function and lower blood pressure. Recent studies suggest that the combination of flavonoids and nitrates can enhance nitric oxide production in the stomach. Their combined effect in the circulation is unclear. Here, our objective was to investigate the independent and additive effects of flavonoid-rich apples and nitrate-rich spinach on nitric oxide status, endothelial function, and blood pressure. A randomized, controlled, crossover trial with healthy men and women (n=30) was conducted. The acute effects of four energy-matched treatments (control, apple, spinach, and apple+spinach), administered in random order, were compared. Measurements included plasma nitric oxide status, assessed by measuring S-nitrosothiols+other nitrosylated species (RXNO) and nitrite, blood pressure, and endothelial function, measured as flow-mediated dilatation of the brachial artery. Results are means and 95% CI. Relative to control, all treatments resulted in higher RXNO (control, 33 nmol/L, 26, 42; apple, 51 nmol/L, 40, 65; spinach, 86 nmol/L, 68, 110; apple+spinach, 69 nmol/L, 54, 88; P<0.01) and higher nitrite (control, 35 nmol/L, 27, 46; apple, 69 nmol/L, 53, 90; spinach, 99 nmol/L, 76, 129; apple+spinach, 80 nmol/L, 61, 104; P<0.01). Compared to control, all treatments resulted in higher flow-mediated dilatation (P<0.05) and lower pulse pressure (P<0.05), and apple and spinach resulted in lower systolic blood pressure (P<0.05). No significant effect was observed on diastolic blood pressure. The combination of apple and spinach did not result in additive effects on nitric oxide status, endothelial function, or blood pressure. In conclusion, flavonoid-rich apples and nitrate-rich spinach can independently augment nitric oxide status, enhance endothelial function, and lower blood pressure acutely, outcomes that may benefit cardiovascular health. Copyright © 2011 Elsevier Inc. All rights reserved.
Palta, Priya; Page, G; Piferi, R L; Gill, J M; Hayat, M J; Connolly, A B; Szanton, S L
2012-04-01
Hypertension affects a large proportion of urban African-American older adults.While there have been great strides in drug development, many older adults do not have access to such medicines or do not take them. Mindfulness-based stress reduction (MBSR)has been shown to decrease blood pressure in some populations. This has not been tested in low-income, urban African-American older adults. Therefore, the primary purpose of this pilot study was to test the feasibility and acceptability of a mindfulness-based program for low income, minority older adults provided in residence. The secondary purpose was to learn if the mindfulness-based program produced differences in blood pressure between the intervention and control groups. Participants were at least 62 years old and residents of a low-income senior residence. All participants were African-American, and one was male.Twenty participants were randomized to the mindfulness-based intervention or a social support control group of the same duration and dose. Blood pressure was measured with the Omron automatic blood pressure machine at baseline and at the end of the 8-week intervention. A multivariate regression analysis was performed on the difference in scores between baseline and post-intervention blood pressure measurements, controlling for age,education, smoking status, and anti-hypertensive medication use. Effect sizes were calculated to quantify the magnitude of the relationship between participation in the mindfulness-based intervention and the outcome variable, blood pressure. Attendance remained 980%in all 8 weeks of both the intervention and the control groups. The average systolic blood pressure decreased for both groups post-intervention. Individuals in the intervention group exhibited a 21.92-mmHg lower systolic blood pressure compared to the social support control group post-intervention and this value was statistically significant(p=0.020). The average diastolic blood pressure decreased in the intervention group postintervention,but increased in the social support group. Individuals in the intervention group exhibited a 16.70-mmHg lower diastolic blood pressure compared to the social support group post-intervention, and this value was statistically significant (p=0.003).Older adults are at a time in life when a reflective, stationary intervention, delivered in residence, could be an appealing mechanism to improve blood pressure. Given our preliminary results, larger trials in this hypertensive study population are warranted.
Pressure-controlled treadmill training in chronic stroke: a case study with AlterG.
Lathan, Cherise; Myler, Andrew; Bagwell, Jennifer; Powers, Christopher M; Fisher, Beth E
2015-04-01
Body-weight-supported treadmill training has been shown to be an effective intervention to improve walking characteristics for individuals who have experienced a stroke. A pressure-controlled treadmill utilizes a sealed chamber in which air pressure can be altered in a controlled manner to counteract the effects of gravity. The focus of this case study was to assess the immediate and short-term impact of a pressure-controlled treadmill to improve gait parameters, reduce fall risk, improve participation, and reduce the self-perceived negative impact of stroke in an individual with chronic stroke. The subject was an 81-year-old man (14.5 months poststroke). He had slow walking speed, poor endurance, and multiple gait deviations. The subject trained 4 times per week for 4 weeks (40 minutes per session) on a pressure-controlled treadmill (AlterG M320) to counter the influence of gravity on the lower extremities. Following training, self-selected gait speed increased from 0.50 m/s to 0.96 m/s, as measured by the 10-meter walk test. Stride length increased from 0.58 m to 0.95 m after training and to 1.00 m at 1-month follow-up. Peak hip flexion increased from 3.7° to 24.6° after training and to 19.4° at 1-month follow-up. Peak knee flexion increased from 19.4° to 34.3° after training and to 42.7° at 1-month follow-up. Measures of endurance, fall risk, and percentage of perceived recovery also were found to improve posttraining. Training with a pressure-controlled treadmill may be a viable alternative to traditional body-weight-supported treadmill training for persons poststroke. Additional studies with larger sample sizes are needed to elucidate the role of pressure-controlled treadmill training in this population. Video abstract available for more insights from the authors (see Supplemental Digital Content 1, http://links.lww.com/JNPT/A97).
Price, G.W.
1954-08-01
A protector device is described for use in controlling the pressure within a cyclotron. In particular, an electrical circuit functions to actuate a vacuum pump when a predetermined low pressure is reached and disconnect the pump when the pressure increases abcve a certain value. The principal feature of the control circuit lies in the use of a voltage divider network at the input to a relay control tube comprising two parallel, adjustable resistances wherein one resistor is switched into the circuit when the relay connects the pump to a power source. With this arrangement the relay is energized at one input level received from a sensing element within the cyclotron chamber and is de-energized when a second input level, representing the higher pressure limit, is reached.
Microfluidic valve with cored glass microneedle for microinjection.
Lee, Sanghoon; Jeong, Wonje; Beebe, David J
2003-08-01
In this paper, a new microinjection device was constructed by fusing a glass microneedle and a PDMS-based microvalve. The microneedle was fabricated via traditional micropipette pulling. The PDMS-based microvalve regulates the fluid flow in the microchannel and microneedle. The 'ON/OFF' operation of the valve was controlled by manually supplied pneumatic pressure. The valve membrane utilized a two level geometry to improve control at low flow rates. The relation between pressure and flow was measured and the results showed that very small volumes of fluid (>1 nl) could be controlled. The valve operation was investigated by monitoring the tip of the needle and pneumatic pressure simultaneously and it demonstrated very stable 'ON/OFF' operation to the pressure change.
Antecedents and Consequences of Mothers' Autonomy Support: An Experimental Investigation.
ERIC Educational Resources Information Center
Grolnick, Wendy S.; Gurland, Suzanne T.; DeCourcey, Wendy; Jacob, Karen
2002-01-01
Examined effects of contextual and individual differences on mothers' autonomy support versus control on homework-like tasks with their third-grade children. Found that mothers in the high-pressure condition were more controlling on the poem task. For the map task, mothers with initial controlling styles in the high-pressure condition were more…
MEMS Reaction Control and Maneuvering for Picosat Beyond LEO
NASA Technical Reports Server (NTRS)
Alexeenko, Alina
2016-01-01
The MEMS Reaction Control and Maneuvering for Picosat Beyond LEO project will further develop a multi-functional small satellite technology for low-power attitude control, or orientation, of picosatellites beyond low Earth orbit (LEO). The Film-Evaporation MEMS Tunable Array (FEMTA) concept initially developed in 2013, is a thermal valving system which utilizes capillary forces in a microchannel to offset internal pressures in a bulk fluid. The local vapor pressure is increased by resistive film heating until it exceeds meniscus strength in a nozzle which induces vacuum boiling and provides a stagnation pressure equal to vapor pressure at that point which is used for propulsion. Interplanetary CubeSats can utilize FEMTA for high slew rate attitude corrections in addition to desaturating reaction wheels. The FEMTA in cooling mode can be used for thermal control during high-power communication events, which are likely to accompany the attitude correction. Current small satellite propulsion options are limited to orbit correction whereas picosatellites are lacking attitude control thrusters. The available attitude control systems are either quickly saturated reaction wheels or movable high drag surfaces with long response times.
Closed-loop Separation Control Using Oscillatory Flow Excitation
NASA Technical Reports Server (NTRS)
Allan, Brian G.; Juang, Jer-Nan; Raney, David L.; Seifert, Avi; Pack, latunia G.; Brown, Donald E.
2000-01-01
Design and implementation of a digital feedback controller for a flow control experiment was performed. The experiment was conducted in a cryogenic pressurized wind tunnel on a generic separated configuration at a chord Reynolds number of 16 million and a Mach number of 0.25. The model simulates the upper surface of a 20% thick airfoil at zero angle-of-attack. A moderate favorable pressure gradient, up to 55% of the chord, is followed by a severe adverse pressure gradient which is relaxed towards the trailing edge. The turbulent separation bubble, behind the adverse pressure gradient, is then reduced by introducing oscillatory flow excitation just upstream of the point of flow separation. The degree of reduction in the separation region can be controlled by the amplitude of the oscillatory excitation. A feedback controller was designed to track a given trajectory for the desired degree of flow reattachment and to improve the transient behavior of the flow system. Closed-loop experiments demonstrated that the feedback controller was able to track step input commands and improve the transient behavior of the open-loop response.
Estimation of excitation forces for wave energy converters control using pressure measurements
NASA Astrophysics Data System (ADS)
Abdelkhalik, O.; Zou, S.; Robinett, R.; Bacelli, G.; Wilson, D.
2017-08-01
Most control algorithms of wave energy converters require prediction of wave elevation or excitation force for a short future horizon, to compute the control in an optimal sense. This paper presents an approach that requires the estimation of the excitation force and its derivatives at present time with no need for prediction. An extended Kalman filter is implemented to estimate the excitation force. The measurements in this approach are selected to be the pressures at discrete points on the buoy surface, in addition to the buoy heave position. The pressures on the buoy surface are more directly related to the excitation force on the buoy as opposed to wave elevation in front of the buoy. These pressure measurements are also more accurate and easier to obtain. A singular arc control is implemented to compute the steady-state control using the estimated excitation force. The estimated excitation force is expressed in the Laplace domain and substituted in the control, before the latter is transformed to the time domain. Numerical simulations are presented for a Bretschneider wave case study.
Quantification of peripheral and central blood pressure variability using a time-frequency method.
Kouchaki, Z; Butlin, M; Qasem, A; Avolio, A P
2016-08-01
Systolic blood pressure variability (BPV) is associated with cardiovascular events. As the beat-to-beat variation of blood pressure is due to interaction of several cardiovascular control systems operating with different response times, assessment of BPV by spectral analysis using the continuous measurement of arterial pressure in the finger is used to differentiate the contribution of these systems in regulating blood pressure. However, as baroreceptors are centrally located, this study considered applying a continuous aortic pressure signal estimated noninvasively from finger pressure for assessment of systolic BPV by a time-frequency method using Short Time Fourier Transform (STFT). The average ratio of low frequency and high frequency power band (LF PB /HF PB ) was computed by time-frequency decomposition of peripheral systolic pressure (pSBP) and derived central aortic systolic blood pressure (cSBP) in 30 healthy subjects (25-62 years) as a marker of balance between cardiovascular control systems contributing in low and high frequency blood pressure variability. The results showed that the BPV assessed from finger pressure (pBPV) overestimated the BPV values compared to that assessed from central aortic pressure (cBPV) for identical cardiac cycles (P<;0.001), with the overestimation being greater at higher power.
NASA Technical Reports Server (NTRS)
Musgrave, M. E.; Gerth, W. A.; Scheld, H. W.; Strain, B. R.
1988-01-01
Mungbean (Phaseolus aureus Roxb.) seedlings were grown hypobarically to assess the effects of low pressure (21-24 kilopascals) on growth and mitochondrial respiration. Control seedlings grown at ambient pressure (101 kilopascals) were provided amounts of O2 equivalent to those provided experimental seedlings at reduced pressure to factor out responses to O2 concentration and to total pressure. Respiration was assayed using washed mitochondria, and was found to respond only to O2 concentration. Regardless of total pressure, seedlings grown at 2 millimoles O2 per liter had higher state 3 respiration rates and decreased percentages of alternative respiration compared to ambient (8.4 millimoles O2 per liter) controls. In contrast, seedling growth responded to total pressure but not to O2 concentration. Seedlings were significantly larger when grown under low pressure. While low O2 (2 millimoles O2 per liter) diminished growth at ambient pressure, growth at low pressure in the same oxygen concentration was enhanced. Respiratory development and growth of mungbean seedlings under low pressure is unimpaired whether oxygen or air is used as the chamber gas, and further, low pressure can improve growth under conditions of poor aeration.
Kim, Ju Young; Wineinger, Nathan E; Steinhubl, Steven R
2016-06-22
Active engagement in the management of hypertension is important in improving self-management behaviors and clinical outcomes. Mobile phone technology using wireless monitoring tools are now widely available to help individuals monitor their blood pressure, but little is known about the conditions under which such technology can effect positive behavior changes or clinical outcomes. To study the influence of wireless self-monitoring program and patient activation measures on health behaviors, medication adherence, and blood pressure levels as well as control of blood pressure in hypertensive patients. We examined a subset of 95 hypertensive participants from a 6-month randomized controlled trial designed to determine the utility of a wireless self-monitoring program (n=52 monitoring program, n=43 control), which consisted of a blood pressure monitoring device connected with a mobile phone, reminders for self-monitoring, a Web-based disease management program, and a mobile app for monitoring and education, compared with the control group receiving a standard disease management program. Study participants provided measures of patient activation, health behaviors including smoking, drinking, and exercise, medication adherence, and blood pressure levels. We assessed the influence of wireless self-monitoring as a moderator of the relationship between patient activation and health behaviors, medication adherence, and control of blood pressure. Improvements in patient activation were associated with improvements in cigarette smoking (beta=-0.46, P<.001) and blood pressure control (beta=0.04, P=.02). This relationship was further strengthened in reducing cigarettes (beta=-0.60, P<.001), alcohol drinking (beta=-0.26, P=.01), and systolic (beta=-0.27, P=.02) and diastolic blood pressure (beta=-0.34, P=.007) at 6 months among individuals participating in the wireless self-monitoring program. No differences were observed with respect to medication adherence. Participation in a wireless self-monitoring program provides individuals motivated to improve their health management with an added benefit above and beyond that of motivation alone. Hypertensive individuals eager to change health behaviors are excellent candidates for mobile health self-monitoring.. ClinicalTrials.gov NCT01975428, https://clinicaltrials.gov/ct2/show/NCT01975428 (Archived by WebCite at http://www.webcitation.org/6iSO5OgOG).
USDA-ARS?s Scientific Manuscript database
Intensive lifestyle management or frequent goal-based monitoring with pharmacological management can be successful strategies for blood pressure control in overweight and obese adults with type 2 diabetes....
143. MOBILE HIGH PRESSURE NITROGEN CART STORED IN CONTROL ROOM ...
143. MOBILE HIGH PRESSURE NITROGEN CART STORED IN CONTROL ROOM (214), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Lowndes, Douglas H.; McCamy, James W.
1996-01-01
A method for growing a deposit upon a substrate of semiconductor material involves the utilization of pulsed laser deposition techniques within a low-pressure gas environment. The substrate and a target of a first material are positioned within a deposition chamber and a low-pressure gas atmosphere is developed within the chamber. The substrate is then heated, and the target is irradiated, so that atoms of the target material are ablated from the remainder of the target, while atoms of the gas simultaneously are adsorbed on the substrate/film surface. The ablated atoms build up upon the substrate, together with the adsorbed gas atoms to form the thin-film deposit on the substrate. By controlling the pressure of the gas of the chamber atmosphere, the composition of the formed deposit can be controlled, and films of continuously variable composition or doping can be grown from a single target of fixed composition.
Atmospheric cloud physics laboratory project study
NASA Technical Reports Server (NTRS)
Schultz, W. E.; Stephen, L. A.; Usher, L. H.
1976-01-01
Engineering studies were performed for the Zero-G Cloud Physics Experiment liquid cooling and air pressure control systems. A total of four concepts for the liquid cooling system was evaluated, two of which were found to closely approach the systems requirements. Thermal insulation requirements, system hardware, and control sensor locations were established. The reservoir sizes and initial temperatures were defined as well as system power requirements. In the study of the pressure control system, fluid analyses by the Atmospheric Cloud Physics Laboratory were performed to determine flow characteristics of various orifice sizes, vacuum pump adequacy, and control systems performance. System parameters predicted in these analyses as a function of time include the following for various orifice sizes: (1) chamber and vacuum pump mass flow rates, (2) the number of valve openings or closures, (3) the maximum cloud chamber pressure deviation from the allowable, and (4) cloud chamber and accumulator pressure.
Apparatus for controlling coolant level in a liquid-metal-cooled nuclear reactor
Jones, Robert D.
1978-01-01
A liquid-metal-cooled fast-breeder reactor which has a thermal liner spaced inwardly of the pressure vessel and includes means for passing bypass coolant through the annulus between the thermal liner and the pressure vessel to insulate the pressure vessel from hot outlet coolant includes control ports in the thermal liner a short distance below the normal operating coolant level in the reactor and an overflow nozzle in the pressure vessel below the control ports connected to an overflow line including a portion at an elevation such that overflow coolant flow is established when the coolant level in the reactor is above the top of the coolant ports. When no makeup coolant is added, bypass flow is inwardly through the control ports and there is no overflow; when makeup coolant is being added, coolant flow through the overflow line will maintain the coolant level.
Waterflood control system for maximizing total oil recovery
Patzek, Tadeusz Wiktor; Silin, Dimitriy Borisovic; De, Asoke Kumar
2005-06-07
A control system and method for determining optimal fluid injection pressure is based upon a model of a growing hydrofracture due to waterflood injection pressure. This model is used to develop a control system optimizing the injection pressure by using a prescribed injection goal coupled with the historical times, pressures, and volume of injected fluid at a single well. In this control method, the historical data is used to derive two major flow components: the transitional component, where cumulative injection volume is scaled as the square root of time, and a steady-state breakthrough component, which scales linearly with respect to time. These components provide diagnostic information and allow for the prevention of rapid fracture growth and associated massive water break through that is an important part of a successful waterflood, thereby extending the life of both injection and associated production wells in waterflood secondary oil recovery operations.
Waterflood control system for maximizing total oil recovery
Patzek, Tadeusz Wiktor [Oakland, CA; Silin, Dimitriy Borisovich [Pleasant Hill, CA; De, Asoke Kumar [San Jose, CA
2007-07-24
A control system and method for determining optimal fluid injection pressure is based upon a model of a growing hydrofracture due to waterflood injection pressure. This model is used to develop a control system optimizing the injection pressure by using a prescribed injection goal coupled with the historical times, pressures, and volume of injected fluid at a single well. In this control method, the historical data is used to derive two major flow components: the transitional component, where cumulative injection volume is scaled as the square root of time, and a steady-state breakthrough component, which scales linearly with respect to time. These components provide diagnostic information and allow for the prevention of rapid fracture growth and associated massive water break through that is an important part of a successful waterflood, thereby extending the life of both injection and associated production wells in waterflood secondary oil recovery operations.
Ducrocq, Emmanuel; Wilson, Mark; Smith, Tim J; Derakshan, Nazanin
2017-12-01
Optimum levels of attentional control are essential to prevent athletes from experiencing performance breakdowns under pressure. The current study explored whether training attentional control using the adaptive dual n-back paradigm, designed to directly target processing efficiency of the main executive functions of working memory (WM), would result in transferrable effects on sports performance outcomes. A total of 30 tennis players were allocated to an adaptive WM training or active control group and underwent 10 days of training. Measures of WM capacity as well as performance and objective gaze indices of attentional control in a tennis volley task were assessed in low- and high-pressure posttraining conditions. Results revealed significant benefits of training on WM capacity, quiet eye offset, and tennis performance in the high-pressure condition. Our results confirm and extend previous findings supporting the transfer of cognitive training benefits to objective measures of sports performance under pressure.
Ventless pressure control of two-phase propellant tanks in microgravity.
Kassemi, Mohammad; Panzarella, Charles H
2004-11-01
This work studies pressurization and pressure control of a large liquid hydrogen storage tank. A finite element model is developed that couples a lumped thermodynamic formulation for the vapor region with a complete solution of the Navier-Stokes and energy equations for the flow and temperature fields in the liquid. Numerical results show that buoyancy effects are strong, even in microgravity, and can reposition a vapor bubble that is initially at the center of the tank to a region near the tank wall in a relatively short time. Long-term tank pressurization with the vapor bubble at the tank wall shows that after an initial transient lasting about a week, the final rate of pressure increase agrees with a purely thermodynamic analysis of the entire tank. However, the final pressure levels are quite different from thermodynamic predictions. Numerical results also show that there is significant thermal stratification in the liquid due to the effects of natural convection. A subcooled jet is used to provide simultaneous cooling and mixing in order to bring the tank pressure back down to its initial value. Three different jet speeds are examined. Although the lowest jet speed is ineffective at controlling the pressure because of insufficient penetration into the liquid region, the highest jet speed is shown to be quite effective at disrupting thermal stratification and reducing the tank pressure in reasonable time.
Ventless pressure control of two-phase propellant tanks in microgravity
NASA Technical Reports Server (NTRS)
Kassemi, Mohammad; Panzarella, Charles H.
2004-01-01
This work studies pressurization and pressure control of a large liquid hydrogen storage tank. A finite element model is developed that couples a lumped thermodynamic formulation for the vapor region with a complete solution of the Navier-Stokes and energy equations for the flow and temperature fields in the liquid. Numerical results show that buoyancy effects are strong, even in microgravity, and can reposition a vapor bubble that is initially at the center of the tank to a region near the tank wall in a relatively short time. Long-term tank pressurization with the vapor bubble at the tank wall shows that after an initial transient lasting about a week, the final rate of pressure increase agrees with a purely thermodynamic analysis of the entire tank. However, the final pressure levels are quite different from thermodynamic predictions. Numerical results also show that there is significant thermal stratification in the liquid due to the effects of natural convection. A subcooled jet is used to provide simultaneous cooling and mixing in order to bring the tank pressure back down to its initial value. Three different jet speeds are examined. Although the lowest jet speed is ineffective at controlling the pressure because of insufficient penetration into the liquid region, the highest jet speed is shown to be quite effective at disrupting thermal stratification and reducing the tank pressure in reasonable time.
NASA Astrophysics Data System (ADS)
Guiltinan, E. J.; Cardenas, M. B.; Cockrell, L.; Espinoza, N.
2017-12-01
The geologic sequestration of CO2 is widely considered a potential solution for decreasing anthropogenic atmospheric CO2 emissions. As CO2 rises buoyantly within a reservoir it pools beneath a caprock and a pressure is exerted upon the pores of the caprock proportionally to the height of the pool. The breakthrough pressure is the point at which CO2 begins to flow freely across the caprock. Understanding the mineralogical and grain size controls on breakthrough pressure is important for screening the security of CO2 sequestration sites. However, breakthrough pressure and permeability measurements on caprocks are difficult to conduct in a systematic manner given the variability in and heterogeneity of naturally occurring mudstones and shales causing significant noise and scatter in the literature. Recent work has even revealed the ability for CO2 to pass through thin shale beds at relatively low pressures. To broaden the understanding of shale breakthrough and permeability, we developed an approach that allows for the creation of resedimented mudstones at high effective stresses. Resedimented samples also include calcium carbonate cement. Using this technique, we explore the controls on entry pressure, breakthrough pressure, and permeability of synthetic mudstones. Understanding the effect of mineralogy and grain size on the permeability and breakthrough pressure of mudstones at reservoir stresses will help in the selection and uncertainty quantification of secure CO2 storage sites.
Wang, Juyong; Asou, Yoshinori; Sekiya, Ichiro; Sotome, Shinichi; Orii, Hisaya; Shinomiya, Kenichi
2006-05-01
To obtain more extensive bone formation in composites of porous ceramics and bone marrow stromal cells (BMSCs), we hypothesized that a low-pressure system would serve to facilitate the perfusion of larger number of BMSCs into the porous scaffold, enhancing bone formation within the composites. After culturing BMSCs in osteogenic medium, porous blocks of beta-tricalcium phosphate (beta-TCP) were soaked in the cell suspension. Composites of the block and BMSCs were put immediately into a vacuum desiccator. Low pressure was applied to the low pressure group, while controls were left at atmospheric pressure. Composites were incubated in vitro or subcutaneously implanted into syngeneic rats, then analyzed biologically and histologically. In the in vitro group, cell suspension volume, cell seeding efficiency, alkaline phosphatase (ALP) activity, and DNA content in the beta-TCP blocks were significantly higher in low pressure group than in the controls. Scanning electron microscopy (SEM) demonstrated that a greater number of cells covered the central parts of the composites in the low pressure group. ALP activity in the composites was increased at 3 and 6 weeks after implantation into rats. Histomorphometric analysis revealed more uniform and extensive bone formation in the low pressure group than in the controls. The application of low pressure during the seeding of BMSCs in perfusing medium into a porous scaffold is useful for tissue-engineered bone formation.
Rolling Maneuver Load Alleviation using active controls
NASA Technical Reports Server (NTRS)
Woods-Vedeler, Jessica A.; Pototzky, Anthony S.
1992-01-01
Rolling Maneuver Load Alleviation (RMLA) has been demonstrated on the Active Flexible Wing (AFW) wind tunnel model in the NASA Langley Transonic Dynamics Tunnel. The design objective was to develop a systematic approach for developing active control laws to alleviate wing incremental loads during roll maneuvers. Using linear load models for the AFW wind-tunnel model which were based on experimental measurements, two RMLA control laws were developed based on a single-degree-of-freedom roll model. The RMLA control laws utilized actuation of outboard control surface pairs to counteract incremental loads generated during rolling maneuvers and actuation of the trailing edge inboard control surface pairs to maintain roll performance. To evaluate the RMLA control laws, roll maneuvers were performed in the wind tunnel at dynamic pressures of 150, 200, and 250 psf and Mach numbers of 0.33, .38 and .44, respectively. Loads obtained during these maneuvers were compared to baseline maneuver loads. For both RMLA controllers, the incremental torsion moments were reduced by up to 60 percent at all dynamic pressures and performance times. Results for bending moment load reductions during roll maneuvers varied. In addition, in a multiple function test, RMLA and flutter suppression system control laws were operated simultaneously during roll maneuvers at dynamic pressures 11 percent above the open-loop flutter dynamic pressure.
Dumas, Tara M; Ellis, Wendy E; Wolfe, David A
2012-08-01
We examined identity development as a moderator of the relation between peer group pressure and control and adolescents' engagement in risk behaviors. Participants (n=1070; M(age)=15.45 years) completed a self-report measure of identity exploration, the degree to which they have explored a variety of self-relevant values, beliefs and goals, and identity commitment, the degree to which they have secured a personal identity. Participants further reported on their frequency of risk behaviors (substance use and general deviancy) and experienced peer group pressure and control. Results confirmed that identity commitment was a buffer of substance use and identity exploration was a buffer of general deviancy in more pressuring peer groups. In more controlling peer groups, teens with greater identity commitment engaged in less risk behavior than teens with low-identity commitment. Thus, identity development may be a suitable target to deter negative effects of peer pressure in high-risk adolescents. Copyright © 2011 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.
Contained radiological analytical chemistry module
Barney, David M.
1989-01-01
A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.
Contained radiological analytical chemistry module
Barney, David M.
1990-01-01
A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.
Sweeping Jet Optimization Studies
NASA Technical Reports Server (NTRS)
Melton, LaTunia Pack; Koklu, Mehti; Andino, Marlyn; Lin, John C.; Edelman, Louis
2016-01-01
Progress on experimental efforts to optimize sweeping jet actuators for active flow control (AFC) applications with large adverse pressure gradients is reported. Three sweeping jet actuator configurations, with the same orifice size but di?erent internal geometries, were installed on the flap shoulder of an unswept, NACA 0015 semi-span wing to investigate how the output produced by a sweeping jet interacts with the separated flow and the mechanisms by which the flow separation is controlled. For this experiment, the flow separation was generated by deflecting the wing's 30% chord trailing edge flap to produce an adverse pressure gradient. Steady and unsteady pressure data, Particle Image Velocimetry data, and force and moment data were acquired to assess the performance of the three actuator configurations. The actuator with the largest jet deflection angle, at the pressure ratios investigated, was the most efficient at controlling flow separation on the flap of the model. Oil flow visualization studies revealed that the flow field controlled by the sweeping jets was more three-dimensional than expected. The results presented also show that the actuator spacing was appropriate for the pressure ratios examined.
Kandzari, David E; Böhm, Michael; Mahfoud, Felix; Townsend, Raymond R; Weber, Michael A; Pocock, Stuart; Tsioufis, Konstantinos; Tousoulis, Dimitrios; Choi, James W; East, Cara; Brar, Sandeep; Cohen, Sidney A; Fahy, Martin; Pilcher, Garrett; Kario, Kazuomi
2018-06-09
Previous catheter-based renal denervation studies have reported variable efficacy results. We aimed to evaluate safety and blood pressure response after renal denervation or sham control in patients with uncontrolled hypertension on antihypertensive medications with drug adherence testing. In this international, randomised, single-blind, sham-control, proof-of-concept trial, patients with uncontrolled hypertension (aged 20-80 years) were enrolled at 25 centres in the USA, Germany, Japan, UK, Australia, Austria, and Greece. Eligible patients had an office systolic blood pressure of between 150 mm Hg and 180 mm Hg and a diastolic blood pressure of 90 mm Hg or higher; a 24 h ambulatory systolic blood pressure of between 140 mm Hg and 170 mm Hg at second screening; and were on one to three antihypertensive drugs with stable doses for at least 6 weeks. Patients underwent renal angiography and were randomly assigned to undergo renal denervation or sham control. Patients, caregivers, and those assessing blood pressure were masked to randomisation assignments. The primary efficacy endpoint was blood pressure change from baseline (measured at screening visit two), based on ambulatory blood pressure measurements assessed at 6 months, as compared between treatment groups. Drug surveillance was used to assess medication adherence. The primary analysis was done in the intention-to-treat population. Safety events were assessed through 6 months as per major adverse events. This trial is registered with ClinicalTrials.gov, number NCT02439775, and follow-up is ongoing. Between July 22, 2015, and June 14, 2017, 467 patients were screened and enrolled. This analysis presents results for the first 80 patients randomly assigned to renal denervation (n=38) and sham control (n=42). Office and 24 h ambulatory blood pressure decreased significantly from baseline to 6 months in the renal denervation group (mean baseline-adjusted treatment differences in 24 h systolic blood pressure -7·0 mm Hg, 95% CI -12·0 to -2·1; p=0·0059, 24 h diastolic blood pressure -4·3 mm Hg, -7·8 to -0·8; p=0.0174, office systolic blood pressure -6·6 mm Hg, -12·4 to -0·9; p=0·0250, and office diastolic blood pressure -4·2 mm Hg, -7·7 to -0·7; p=0·0190). The change in blood pressure was significantly greater at 6 months in the renal denervation group than the sham-control group for office systolic blood pressure (difference -6·8 mm Hg, 95% CI -12·5 to -1·1; p=0·0205), 24 h systolic blood pressure (difference -7·4 mm Hg, -12·5 to -2·3; p=0·0051), office diastolic blood pressure (difference -3·5 mm Hg, -7·0 to -0·0; p=0·0478), and 24 h diastolic blood pressure (difference -4·1 mm Hg, -7·8 to -0·4; p=0·0292). Evaluation of hourly changes in 24 h systolic blood pressure and diastolic blood pressure showed blood pressure reduction throughout 24 h for the renal denervation group. 3 month blood pressure reductions were not significantly different between groups. Medication adherence was about 60% and varied for individual patients throughout the study. No major adverse events were recorded in either group. Renal denervation in the main renal arteries and branches significantly reduced blood pressure compared with sham control with no major safety events. Incomplete medication adherence was common. Medtronic. Copyright © 2018 Elsevier Ltd. All rights reserved.
Postaerobic Exercise Blood Pressure Reduction in Very Old Persons With Hypertension.
Oliveira, Joana; Mesquita-Bastos, José; Argel de Melo, Cristina; Ribeiro, Fernando
2016-01-01
A single bout of aerobic exercise acutely decreases blood pressure, even in older adults with hypertension. Nonetheless, blood pressure responses to aerobic exercise in very old adults with hypertension have not yet been documented. Therefore, this study aimed to assess the effect of a single session of aerobic exercise on postexercise blood pressure in very old adults with hypertension. Eighteen older adults with essential hypertension were randomized into exercise (N = 9, age: 83.4 ± 3.2 years old) or control (N = 9, age: 82.7 ± 2.5 years old) groups. The exercise group performed a session of aerobic exercise constituting 2 periods of 10 minutes of walking at an intensity of 40% to 60% of the heart rate reserve. The control group rested for the same period of time. Anthropometric variables and medication status were evaluated at baseline. Heart rate and systolic and diastolic blood pressures were measured at baseline, after exercise, and at 20 and 40 minutes postexercise. Systolic blood pressure showed a significant interaction for group × time (F3,24 = 6.698; P = .002; ηp(2) = 0.153). In the exercise group, the systolic blood pressure at 20 (127.3 ± 20.9 mm Hg) and 40 minutes (123.7 ± 21.0 mm Hg) postexercise was significantly lower in comparison with baseline (135.6 ± 20.6 mm Hg). Diastolic blood pressure did not change. Heart rate was significantly higher after the exercise session. In the control group, no significant differences were observed. A single session of aerobic exercise acutely reduces blood pressure in very old adults with hypertension and may be considered an important nonpharmacological strategy to control hypertension in this age group.
Pavone, Lucio A; Albert, Scott; Carney, David; Gatto, Louis A; Halter, Jeffrey M; Nieman, Gary F
2007-01-01
Acute respiratory distress syndrome causes a heterogeneous lung injury, and without protective mechanical ventilation a secondary ventilator-induced lung injury can occur. To ventilate noncompliant lung regions, high inflation pressures are required to 'pop open' the injured alveoli. The temporal impact, however, of these elevated pressures on normal alveolar mechanics (that is, the dynamic change in alveolar size and shape during ventilation) is unknown. In the present study we found that ventilating the normal lung with high peak pressure (45 cmH(2)0) and low positive end-expiratory pressure (PEEP of 3 cmH(2)O) did not initially result in altered alveolar mechanics, but alveolar instability developed over time. Anesthetized rats underwent tracheostomy, were placed on pressure control ventilation, and underwent sternotomy. Rats were then assigned to one of three ventilation strategies: control group (n = 3, P control = 14 cmH(2)O, PEEP = 3 cmH(2)O), high pressure/low PEEP group (n = 6, P control = 45 cmH(2)O, PEEP = 3 cmH(2)O), and high pressure/high PEEP group (n = 5, P control = 45 cmH(2)O, PEEP = 10 cmH(2)O). In vivo microscopic footage of subpleural alveolar stability (that is, recruitment/derecruitment) was taken at baseline and than every 15 minutes for 90 minutes following ventilator adjustments. Alveolar recruitment/derecruitment was determined by measuring the area of individual alveoli at peak inspiration (I) and end expiration (E) by computer image analysis. Alveolar recruitment/derecruitment was quantified by the percentage change in alveolar area during tidal ventilation (%I - E Delta). Alveoli were stable in the control group for the entire experiment (low %I - E Delta). Alveoli in the high pressure/low PEEP group were initially stable (low %I - E Delta), but with time alveolar recruitment/derecruitment developed. The development of alveolar instability in the high pressure/low PEEP group was associated with histologic lung injury. A large change in lung volume with each breath will, in time, lead to unstable alveoli and pulmonary damage. Reducing the change in lung volume by increasing the PEEP, even with high inflation pressure, prevents alveolar instability and reduces injury. We speculate that ventilation with large changes in lung volume over time results in surfactant deactivation, which leads to alveolar instability.
NASA Astrophysics Data System (ADS)
Mavkov, B.; Witrant, E.; Prieur, C.; Maljaars, E.; Felici, F.; Sauter, O.; the TCV-Team
2018-05-01
In this paper, model-based closed-loop algorithms are derived for distributed control of the inverse of the safety factor profile and the plasma pressure parameter β of the TCV tokamak. The simultaneous control of the two plasma quantities is performed by combining two different control methods. The control design of the plasma safety factor is based on an infinite-dimensional setting using Lyapunov analysis for partial differential equations, while the control of the plasma pressure parameter is designed using control techniques for single-input and single-output systems. The performance and robustness of the proposed controller is analyzed in simulations using the fast plasma transport simulator RAPTOR. The control is then implemented and tested in experiments in TCV L-mode discharges using the RAPTOR model predicted estimates for the q-profile. The distributed control in TCV is performed using one co-current and one counter-current electron cyclotron heating actuation.
Measurement and Control of Oxygen Partial Pressure in an Electrostatic Levitator
NASA Technical Reports Server (NTRS)
SanSoucie, Michael P.; Rogers, Jan R.
2014-01-01
Recently the NASA Marshall Space Flight Center electrostatic levitation (ESL) laboratory has been upgraded to include an oxygen control system. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, at elevated temperatures, theoretically in the range from 10(exp -36) to 10(exp 0) bar. The role of active surface agents in liquid metals is fairly well known; however, published surface tension data typically has large scatter, which has been hypothesized to be caused by the presence of oxygen. The surface tension of metals is affected by even a small amount of adsorption of oxygen. It has even been shown that oxygen partial pressures may need to be as low as 10(exp -24) bar to avoid oxidation. While electrostatic levitation is done under high vacuum, oxide films or dissolved oxygen may have significant effects on materials properties, such as surface tension and viscosity. Therefore, the ability to measure and control the oxygen partial pressure within the chamber is highly desirable. The oxygen control system installed at MSFC contains a potentiometric sensor, which measures the oxygen partial pressure, and an oxygen ion pump. In the pump, a pulse-width modulated electric current is applied to yttrium-stabilized zirconia, resulting in oxygen transfer into or out of the system. Also part of the system is a control unit, which consists of temperature controllers for the sensor and pump, PID-based current loop for the ion pump, and a control algorithm. This system can be used to study the effects of oxygen on the thermophysical properties of metals, ceramics, glasses, and alloys. It can also be used to provide more accurate measurements by processing the samples at very low oxygen partial pressures. The oxygen control system will be explained in more detail and an overview of its use and limitations in an electrostatic levitator will be described. Some preliminary measurements have been made, and the results to date will be provided.
Martínez-García, Miguel-Angel; Capote, Francisco; Campos-Rodríguez, Francisco; Lloberes, Patricia; Díaz de Atauri, María Josefa; Somoza, María; Masa, Juan F; González, Mónica; Sacristán, Lirios; Barbé, Ferrán; Durán-Cantolla, Joaquín; Aizpuru, Felipe; Mañas, Eva; Barreiro, Bienvenido; Mosteiro, Mar; Cebrián, Juan J; de la Peña, Mónica; García-Río, Francisco; Maimó, Andrés; Zapater, Jordi; Hernández, Concepción; Grau SanMarti, Nuria; Montserrat, Josep María
2013-12-11
More than 70% of patients with resistant hypertension have obstructive sleep apnea (OSA). However, there is little evidence about the effect of continuous positive airway pressure (CPAP) treatment on blood pressure in patients with resistant hypertension. To assess the effect of CPAP treatment on blood pressure values and nocturnal blood pressure patterns in patients with resistant hypertension and OSA. Open-label, randomized, multicenter clinical trial of parallel groups with blinded end point design conducted in 24 teaching hospitals in Spain involving 194 patients with resistant hypertension and an apnea-hypopnea index (AHI) of 15 or higher. Data were collected from June 2009 to October 2011. CPAP or no therapy while maintaining usual blood pressure control medication. The primary end point was the change in 24-hour mean blood pressure after 12 weeks. Secondary end points included changes in other blood pressure values and changes in nocturnal blood pressure patterns. Both intention-to-treat (ITT) and per-protocol analyses were performed. A total of 194 patients were randomly assigned to receive CPAP (n = 98) or no CPAP (control; n = 96). The mean AHI was 40.4 (SD, 18.9) and an average of 3.8 antihypertensive drugs were taken per patient. Baseline 24-hour mean blood pressure was 103.4 mm Hg; systolic blood pressure (SBP), 144.2 mm Hg; and diastolic blood pressure (DBP), 83 mm Hg. At baseline, 25.8% of patients displayed a dipper pattern (a decrease of at least 10% in the average nighttime blood pressure compared with the average daytime blood pressure). The percentage of patients using CPAP for 4 or more hours per day was 72.4%. When the changes in blood pressure over the study period were compared between groups by ITT, the CPAP group achieved a greater decrease in 24-hour mean blood pressure (3.1 mm Hg [95% CI, 0.6 to 5.6]; P = .02) and 24-hour DBP (3.2 mm Hg [95% CI, 1.0 to 5.4]; P = .005), but not in 24-hour SBP (3.1 mm Hg [95% CI, -0.6 to 6.7]; P = .10) compared with the control group. Moreover, the percentage of patients displaying a nocturnal blood pressure dipper pattern at the 12-week follow-up was greater in the CPAP group than in the control group (35.9% vs 21.6%; adjusted odds ratio [OR], 2.4 [95% CI, 1.2 to 5.1]; P = .02). There was a significant positive correlation between hours of CPAP use and the decrease in 24-hour mean blood pressure (r = 0.29, P = .006), SBP (r = 0.25; P = .02), and DBP (r = 0.30, P = .005). Among patients with OSA and resistant hypertension, CPAP treatment for 12 weeks compared with control resulted in a decrease in 24-hour mean and diastolic blood pressure and an improvement in the nocturnal blood pressure pattern. Further research is warranted to assess longer-term health outcomes. clinicaltrials.gov Identifier: NCT00616265.
ERIC Educational Resources Information Center
Marsh, A. R.
1972-01-01
Describes experiments demonstrating that root pressure in plants is probably controlled by a circadian rhythm (biological clock). Root pressure phenomenon plays significant part in water transport in contradiction with prevalent belief. (PS)
Postural control is altered in patients with ankylosing spondylitis.
Vergara, Martin E; O'Shea, Finbar D; Inman, Robert D; Gage, William H
2012-05-01
Ankylosing spondylitis is a chronic inflammatory disorder that can lead to increased axial and peripheral joint stiffness, impairing joint mobility. Impaired axial mobility due to vertebral ankylosis may result in changes in standing postural control. Little research has addressed changes in standing postural control in the ankylosing spondylitis population, nor how these issues might affect clinical understanding and treatment. Sixteen ankylosing spondylitis patients, and 17 healthy controls participated. Each individual completed two 120-second quiet standing trials with eyes open and eyes closed, while standing upon two force platforms. Net center of pressure displacement and mean power frequency in the frontal and sagittal planes were calculated. A Spearman's rank correlation analysis was performed between net center of pressure measures and several clinical measures of disease activity. Frontal plane net center of pressure displacement and frequency content, and sagittal plane net center of pressure displacement were significantly greater within the ankylosing spondylitis patient group. Ankylosing spondylitis patients demonstrated a significant increase in frontal plane net center of pressure displacement in the eyes-closed condition. Net center of pressure displacement and frequency were significantly correlated to the Bath Ankylosing Spondylitis Functional Index, and individual components of the Bath Ankylosing Spondylitis Metrology Index. Quiet standing postural control was altered particularly so in the frontal plane in patients with ankylosing spondylitis, which may be associated with increased fall risk. Posturographic measures of postural control may serve as valuable clinical tools for the monitoring of disease progression and disease status in ankylosing spondylitis. Copyright © 2011 Elsevier Ltd. All rights reserved.
An improved sample loading technique for cellular metabolic response monitoring under pressure
NASA Astrophysics Data System (ADS)
Gikunda, Millicent Nkirote
To monitor cellular metabolism under pressure, a pressure chamber designed around a simple-to-construct capillary-based spectroscopic chamber coupled to a microliter-flow perfusion system is used in the laboratory. Although cyanide-induced metabolic responses from Saccharomyces cerevisiae (baker's yeast) could be controllably induced and monitored under pressure, previously used sample loading technique was not well controlled. An improved cell-loading technique which is based on use of a secondary inner capillary into which the sample is loaded then inserted into the capillary pressure chamber, has been developed. As validation, we demonstrate the ability to measure the chemically-induced metabolic responses at pressures of up to 500 bars. This technique is shown to be less prone to sample loss due to perfusive flow than the previous techniques used.
Controlling and assessing pressure conditions during treatment of tar sands formations
Zhang, Etuan; Beer, Gary Lee
2015-11-10
A method for treating a tar sands formation includes providing heat to at least part of a hydrocarbon layer in the tar sands formation from a plurality of heaters located in the formation. Heat is allowed to transfer from the heaters to at least a portion of the formation. A pressure in the portion of the formation is controlled such that the pressure remains below a fracture pressure of the formation overburden while allowing the portion of the formation to heat to a selected average temperature of at least about 280.degree. C. and at most about 300.degree. C. The pressure in the portion of the formation is reduced to a selected pressure after the portion of the formation reaches the selected average temperature.
Pressure effect on dissimilatory sulfate reduction
NASA Astrophysics Data System (ADS)
Williamson, A. J.; Carlson, H. K.; Coates, J. D.
2015-12-01
Biosouring is the production of H2S by sulfate reducing microorganisms (SRM) in-situ or in the produced fluids of oil reservoirs. Sulfide is explosive, toxic and corrosive which can trigger equipment and transportation failure, leading to environmental catastrophe. As oil exploration and reservoir development continue, subsequent enhanced recovery is occurring in progressively deeper formations and typical oil reservoir pressures range from 10-50 MPa. Therefore, an understanding of souring control effects will require an accurate understanding of the influence of pressure on SRM metabolism and the efficacy of souring control treatments at high pressure. Considerable work to date has focussed on souring control at ambient pressure; however, the influence of pressure on biogeochemical processes and souring treatments in oil reservoirs is poorly understood. To explore the impact of pressure on SRM, wild type Desulfovibrio alaskensis G20 (isolated from a producing oil well in Ventura County, California) was grown under a range of pressures (0.1-14 MPa) at 30 °C. Complete sulfate reduction occurred in all pressures tested within 3 days, but microbial growth was inhibited with increasing pressure. Bar-seq identified several genes associated with flagella biosynthesis (including FlhB) and assembly as important for survival at elevated pressure and fitness was confirmed using individual transposon mutants. Flagellar genes have previously been implicated with biofilm formation and confocal microscopy on glass slides incubated with wild type D. alaskensis G20 showed more biomass associated with surfaces under pressure, highlighting the link between pressure, flagellar and biofilm formation. To determine the effect of pressure on the efficacy of SRM inhibitors, IC50 experiments were conducted and D. alaskensis G20 showed a greater resistance to nitrate and the antibiotic chloramphenicol, but a lower resistance to perchlorate. These results will be discussed in the context of deep subsurface microbiology and oil reservoir biosouring. Overall, this work furthers our understanding of oil reservoir biogeochemistry and highlights the impact of pressure on biofilm formation and biosouring strategies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin
Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less
Development of a Facility for Combustion Stability Experiments at Supercritical Pressure
2013-12-01
by the exhaust orifice. This technique adds freedom for designing a large array experimental conditions, because chamber pressure is controlled...analytical examination reveals a broad array of frequencies. The analytical relationship between chamber length L, acoustic frequency fF, and the speed...the pressure amplitude is directly controlled by altering the voltage input to the sirens, similar to a traditional loudspeaker . Last, both a PN and
Air Pressure Controlled Mass Measurement System
NASA Astrophysics Data System (ADS)
Zhong, Ruilin; Wang, Jian; Cai, Changqing; Yao, Hong; Ding, Jin'an; Zhang, Yue; Wang, Xiaolei
Mass measurement is influenced by air pressure, temperature, humidity and other facts. In order to reduce the influence, mass laboratory of National Institute of Metrology, China has developed an air pressure controlled mass measurement system. In this system, an automatic mass comparator is installed in an airtight chamber. The Chamber is equipped with a pressure controller and associate valves, thus the air pressure can be changed and stabilized to the pre-set value, the preferred pressure range is from 200 hPa to 1100 hPa. In order to keep the environment inside the chamber stable, the display and control part of the mass comparator are moved outside the chamber, and connected to the mass comparator by feed-throughs. Also a lifting device is designed for this system which can easily lift up the upper part of the chamber, thus weights can be easily put inside the mass comparator. The whole system is put on a marble platform, and the temperature and humidity of the laboratory is very stable. The temperature, humidity, and carbon dioxide content inside the chamber are measured in real time and can be used to get air density. Mass measurement cycle from 1100 hPa to 200 hPa and back to 1100 hPa shows the effective of the system.
Reversible Morphological Control of Tubulin-Encapsulating Giant Liposomes by Hydrostatic Pressure.
Hayashi, Masahito; Nishiyama, Masayoshi; Kazayama, Yuki; Toyota, Taro; Harada, Yoshie; Takiguchi, Kingo
2016-04-19
Liposomes encapsulating cytoskeletons have drawn much recent attention to develop an artificial cell-like chemical-machinery; however, as far as we know, there has been no report showing isothermally reversible morphological changes of liposomes containing cytoskeletons because the sets of various regulatory factors, that is, their interacting proteins, are required to control the state of every reaction system of cytoskeletons. Here we focused on hydrostatic pressure to control the polymerization state of microtubules (MTs) within cell-sized giant liposomes (diameters ∼10 μm). MT is the cytoskeleton formed by the polymerization of tubulin, and cytoskeletal systems consisting of MTs are very dynamic and play many important roles in living cells, such as the morphogenesis of nerve cells and formation of the spindle apparatus during mitosis. Using real-time imaging with a high-pressure microscope, we examined the effects of hydrostatic pressure on the morphology of tubulin-encapsulating giant liposomes. At ambient pressure (0.1 MPa), many liposomes formed protrusions due to tubulin polymerization within them. When high pressure (60 MPa) was applied, the protrusions shrank within several tens of seconds. This process was repeatedly inducible (around three times), and after the pressure was released, the protrusions regenerated within several minutes. These deformation rates of the liposomes are close to the velocities of migrating or shape-changing living cells rather than the shortening and elongation rates of the single MTs, which have been previously measured. These results demonstrate that the elongation and shortening of protrusions of giant liposomes is repeatedly controllable by regulating the polymerization state of MTs within them by applying and releasing hydrostatic pressure.
The influence of exogenous cross-linking and compressive creep loading on intradiscal pressure.
Chuang, Shih-Youeng; Lin, Leou-Chyr; Hedman, Thomas P
2010-10-01
This study involves a biomechanical evaluation of a prospective injectable treatment for degenerative discs. The high osmolarity of the non-degenerated nucleus pulposus attracts water contributing to the hydrostatic behavior of the tissue. This intradiscal pressure is known to drop as fluid is exuded from the matrix due to compressive loading. The objective of this study was to compare the changes in intradiscal pressure in control and genipin cross-linked intervertebral discs. Thirty bovine lumbar motion segments were randomly divided into a phosphate-buffered saline control group and a 0.33% genipin group and soaked at room temperature for 2 days. A needle pressure sensor was held in the center of the disc while short-term and static creep compressive loads were applied. The control group demonstrated a 25% higher average intradiscal pressure compared to genipin-treated discs under 750 N compressive load (p=0.029). Depressurization during static compressive creep was 56% higher in the control than in the genipin group (p=0.014). These results suggest cross-linking induced changes in the poroelastic properties of the involved tissues affected the mechanics of compressive load support in the disc with lower levels of nucleus pressure, a corresponding decrease in the elastic expansion of the annulus, and an increased axial compressive loading of the inner and outer annulus tissues. It is possible that concurrent changes in hydraulic permeability and proteoglycan retention known to be associated with genipin cross-linking were also contributors to poroelastic changes. Reduction of peak pressures and moderation of pressure fluctuations could be beneficial relative to discogenic pain.
21. VIEW TO NORTHWEST, ENGINE/PUMP HOUSE EXTENSION, HIGH PRESSURE PISTON ...
21. VIEW TO NORTHWEST, ENGINE/PUMP HOUSE EXTENSION, HIGH PRESSURE PISTON OF STEAM ENGINE NO. 4; CONTROL PANEL MOUNTED ON THE ENGINE; FLOOR VALVES CONTROL THE STEAM. - Deer Island Pumping Station, Boston, Suffolk County, MA
Code of Federal Regulations, 2012 CFR
2012-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
Code of Federal Regulations, 2013 CFR
2013-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
Code of Federal Regulations, 2011 CFR
2011-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
Code of Federal Regulations, 2012 CFR
2012-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
Code of Federal Regulations, 2014 CFR
2014-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
Code of Federal Regulations, 2014 CFR
2014-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
Code of Federal Regulations, 2013 CFR
2013-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
Code of Federal Regulations, 2011 CFR
2011-07-01
... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...
NASA Technical Reports Server (NTRS)
Grugel, R.N.; Lee, C.P.; Cox, M.C.; Blandford, B.T.; Anilkumar, A.V.
2008-01-01
Controlled directional solidification experiments were performed in capillary channels, using nitrogen-saturated succinonitrile, to examine the effect of an in-situ stepwise processing pressure increase on an isolated pore evolution. Two experiments were performed using different processing pressure input profiles. The results indicate that a processing pressure increase has a transient effect on pore growth geometry characterized by an initial phase of decreasing pore diameter, followed by a recovery phase of increasing pore diameter. The experimental results also show that processing pressure can be used as a control parameter to either increase or terminate porosity formation. A theoretical model is introduced which indicates that the pore formation process is limited by the diffusion of solute-gas through the melt, and that the observed response toa pressure increase is attributed to the re-equilibration of solute concentration in the melt associated with the increased melt pressure.
System and method for continuous solids slurry depressurization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leininger, Thomas Frederick; Steele, Raymond Douglas; Yen, Hsien-Chin William
A continuous slag processing system includes a rotating parallel disc pump, coupled to a motor and a brake. The rotating parallel disc pump includes opposing discs coupled to a shaft, an outlet configured to continuously receive a fluid at a first pressure, and an inlet configured to continuously discharge the fluid at a second pressure less than the first pressure. The rotating parallel disc pump is configurable in a reverse-acting pump mode and a letdown turbine mode. The motor is configured to drive the opposing discs about the shaft and against a flow of the fluid to control a differencemore » between the first pressure and the second pressure in the reverse-acting pump mode. The brake is configured to resist rotation of the opposing discs about the shaft to control the difference between the first pressure and the second pressure in the letdown turbine mode.« less
Numerical Investigation of Microgravity Tank Pressure Rise Due to Boiling
NASA Technical Reports Server (NTRS)
Hylton, Sonya; Ibrahim, Mounir; Kartuzova, Olga; Kassemi, Mohammad
2015-01-01
The ability to control self-pressurization in cryogenic storage tanks is essential for NASAs long-term space exploration missions. Predictions of the tank pressure rise in Space are needed in order to inform the microgravity design and optimization process. Due to the fact that natural convection is very weak in microgravity, heat leaks into the tank can create superheated regions in the liquid. The superheated regions can instigate microgravity boiling, giving rise to pressure spikes during self-pressurization. In this work, a CFD model is developed to predict the magnitude and duration of the microgravity pressure spikes. The model uses the Schrage equation to calculate the mass transfer, with a different accommodation coefficient for evaporation at the interface, condensation at the interface, and boiling in the bulk liquid. The implicit VOF model was used to account for the moving interface, with bounded second order time discretization. Validation of the models predictions was carried out using microgravity data from the Tank Pressure Control Experiment, which flew aboard the Space Shuttle Mission STS-52. Although this experiment was meant to study pressurization and pressure control, it underwent boiling during several tests. The pressure rise predicted by the CFD model compared well with the experimental data. The ZBOT microgravity experiment is scheduled to fly on February 2016 aboard the ISS. The CFD model was also used to perform simulations for setting parametric limits for the Zero-Boil-Off Tank (ZBOT) Experiments Test Matrix in an attempt to avoid boiling in the majority of the test runs that are aimed to study pressure increase rates during self-pressurization. *Supported in part by NASA ISS Physical Sciences Research Program, NASA HQ, USA
Zegarra-Parodi, Rafael; Pazdernik, Vanessa K; Roustit, Matthieu; Park, Peter Yong Soo; Degenhardt, Brian F
2016-02-01
Peripheral skin blood flow (SBF) changes during and after spinal mobilization (SM), evaluated with laser Doppler flowmetry, may document physiological responses associated with SM. To document variations in SBF during and after application of an SM and evaluate influence of pressure on SBF by applying the same standardized SM with 3 different nonnoxious pressures. Cross-over design with 4 interventions on 4 different days: control (no touch) and 3 SMs applied rhythmically at 5%, 40%, or 80% of pain pressure threshold (sham SM, low-pressure SM, or high-pressure SM, respectively). Thirty-two individuals participated. The inspiratory gasp (IG) test was our positive control of vasoconstriction through excitation of the skin sympathetic nervous activity (SSNA). Each session comprised 5 phases: (1) baseline at the end of a 20-min acclimatization, (2) IG test, (3) post-IG phase, (4) SM phase or no manual contact for control, and (5) post-SM phase. A Biopac MP36 system collected SBF data, and a Novel Pliance-X system recorded pressure data. Equal and significant bilateral vasodilation occurred during application of unilateral sham SM, low-pressure SM, and high-pressure SM. Post-SM significant vasodilation persisted after high-pressure SM. The current study is the first to describe bilateral peripheral SBF changes occurring during and 5 min after application of standardized SMs. Our post-SM vasodilation suggests involvement of mechanisms other than the putative SSNA-excitatory mechanism proposed with skin conductance measurements. Persistence of post-SM vasodilation following only high-pressure SM suggests possible pressure-dependent mechanisms. However, further research is warranted to clarify our findings. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rondon, Atila; Leslie, Bruno; Arcuri, Leonardo Javier; Ortiz, Valdemar; Macedo, Antonio
2015-09-01
To assess whether crossing rectus abdominis muscle strips, as proposed by Yachia, would change urinary catheterizable conduit's pressure profilometry, in static and dynamic conditions. Non-randomized selection of 20 continent patients that underwent Macedo's ileum-based reservoir, 10 including Yachia's technique (Study Group) and 10 without this mechanism of continence (Control Group). Demographics and cystometric data were assessed. Conduit's pressure profilometry was obtained by infusing saline through a multichannel catheter, at rest and during Valsalva maneuver. We assessed the pressure: (a) in the bladder; (b) in conduit's proximal segment; and (c) in conduit's distal segment, which is presumably the abdominal wall and crossed muscle strips site. Mean age at surgery was 6.1 years in the Control Group and 7.7 years in the Study Group. There was no statistically significant difference between groups regarding maximum cystometric bladder capacity and leakage point pressure. At rest, the pressure profilometry showed similar results between groups in all segments analyzed. During Valsalva maneuver, pressure profilometry showed similar results between groups in bladder and conduit's proximal segment pressure. In this condition, conduit's distal segment pressure in the Study Group (Mean = 72.9 and Peak = 128.7 cmH2 O) was significantly greater (P < 0.05) than conduit's distal segment pressure in the Control Group (Mean = 48.3 and Peak = 65.1 cmH2 O). Crossing muscle strips over the conduit significantly increases the pressure in its distal segment during contraction of the rectus abdominis muscle, which can be important in moments of sudden increase in abdominal pressure in order to keep continence. © 2014 Wiley Periodicals, Inc.
Intramedullary pressure changes in rats after spinal cord injury.
Dong, X; Yang, D; Li, J; Liu, C; Yang, M; Du, L; Gu, R; Hu, A; Zhang, H
2016-11-01
The objectives of this study were to explore the change of intramedullary pressure over time in rats after different degrees of spinal cord contusion injury and to verify the hypothesis that the more serious the injury, the higher the intramedullary pressure. The control group rats underwent laminectomy only, whereas the rats in the three experimental groups were subjected to mild, moderate or severe 10th thoracic cord (T10) contusion injury after laminectomy. In addition, an intramedullary pressure of T10 was measured by a Millar Mikro-Tip pressure catheter (Millar Incorporated Company, Houston, TX, USA) immediately in the control group or at different time points after injury in the experimental groups. The average intramedullary pressure of the rats in the control group was 6.88±1.67 mm Hg, whereas that of the rats in any injury group was significantly higher (P=0.000). There was statistical difference among the different time points in the mild or moderate injury group (P=0.007/0.017), but no in the severe (P=0.374). The curves of intramedullary pressure over time in the mild and moderate injury group were bimodal, peaking at 1 and 48 h after the injury. The intramedullary pressure after injury was positively correlated with the injury degree (r=0.438, P=0.000). The intramedullary pressure of the rats increased after traumatic spinal cord injury. If the injury was not serious, the intramedullary pressure fluctuated with time and peaked at 1 and 48 h after injury. If the injury was serious, the intramedullary pressure remained high. The more serious the injury, the higher the intramedullary pressure.
Agyemang, Charles; Kunst, Anton E; Bhopal, Raj; Zaninotto, Paola; Unwin, Nigel; Nazroo, James; Nicolaou, Mary; Redekop, William K; Stronks, Karien
2011-01-01
To compare blood pressure and the prevalence of hypertension in white Dutch and Dutch of Suriname-hindustani and Suriname-creole ethnic derivation with corresponding ethnic minority groups in England and to assess the quality of hypertension treatment in these groups. Retrospective; comparison of cross-sectional studies. Secondary analyses were performed on data from 3 population-based studies with 13,999 participants in total of European, African of South-Asian origin from England and the Netherlands. English South-Asian men and women had lower blood pressure and lower prevalence of hypertension than people of South-Asian origin in the Netherlands (Suriname-hindustani), except for systolic blood pressure in men of Indian extraction in England. There was no difference in systolic blood pressure between groups of African origin in the Netherlands and England. Diastolic blood pressure levels, however, were lower in English men and women of African origin than in people of African origin in the Netherlands (Suriname-creole). White Dutch had higher systolic blood pressure levels, but lower diastolic blood pressure levels than white English men and women. There was no difference in the prevalence of hypertension between the white groups. In persons being treated for hypertension, a substantially lower percentage of the Suriname-hindustani and Suriname-creole persons in the Netherlands had well controlled blood pressure (lower than 140/90 mmHg) than their English equivalents, with the exception of English of Indian extraction. There were marked differences in blood pressure and prevalence of hypertension between comparable ethnic groups in England and the Netherlands. The relatively poor blood pressure control in Dutch ethnic minority groups partly explained the relatively high blood pressure levels in these groups.
NASA Astrophysics Data System (ADS)
Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang
2018-03-01
Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.
Loss of control air at Browns Ferry Unit One: accident sequence analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrington, R.M.; Hodge, S.A.
1986-04-01
This study describes the predicted response of the Browns Ferry Nuclear Plant to a postulated complete failure of plant control air. The failure of plant control air cascades to include the loss of drywell control air at Units 1 and 2. Nevertheless, this is a benign accident unless compounded by simultaneous failures in the turbine-driven high pressure injection systems. Accident sequence calculations are presented for Loss of Control Air sequences with assumed failure upon demand of the Reactor Core Isolation Cooling (RCIC) and the High Pressure Coolant Injection (HPCI) at Unit 1. Sequences with and without operator action are considered.more » Results show that the operators can prevent core uncovery if they take action to utilize the Control Rod Drive Hydraulic System as a backup high pressure injection system.« less
1975-01-29
will shut down automatically when condenser high pressure causes Pressure Limit Control high pressure switch to release. Press START switch (3...power cable (1) from facility pow- er. Troubleshoot cooling unit, for HI-LOW pressure switch repeated cutout. Refer to AGE ECU Cooling Unit...acti- vate when loss of air flow oc- curred, the pressure switch (3) failed to open circuit. Adjust or replace pressure switch . Refer to
System for detecting operating errors in a variable valve timing engine using pressure sensors
Wiles, Matthew A.; Marriot, Craig D
2013-07-02
A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.
Kwong, Enid Wai-yung; Lee, Paul Hong; Yeung, Kwan-mo
2016-01-18
Because the demand for government-subsidized nursing homes in Hong Kong outstrips the supply, the number of for-profit private nursing homes has been increasing rapidly. However, the standard of care in such homes is always criticized. Pressure ulcers are a major long-term care issue that is closely associated with the quality of care delivered in nursing home settings. The aim of this study is to evaluate the effectiveness of a pressure ulcer prevention programme for residents in private for-profit nursing homes. This is a two-arm cluster randomized controlled trial with an estimated sample size of 1088 residents and 74 care staff from eight for-profit private nursing homes. Eligible nursing homes will be those classified as category A2 homes in the Enhanced Bought Place Scheme (EBPS), having a capacity of around 130-150 beds, and no structured PU prevention protocol and/or programmes in place. Care staff will be health workers, personal care workers, and nurses who are front-line staff providing direct care to residents. Eight nursing homes will be randomly assigned to either an experimental or control group. The experimental group will be provided with an intensive training programme and will be involved in the implementation of a 16-week pressure ulcer prevention protocol, while the control group will deliver the usual pressure ulcer prevention care. The study outcomes are the pressure ulcer prevention knowledge and skills of the care staff and the prevalence and incidence of pressure ulcers. Data on the knowledge and skills of care staff, and prevalence of pressure ulcer will be collected at the base line, and then at the 8(th) week and at completion of the implementation of the protocol. The assessment of the incidence of pressures will start from before the commencement of the intensive training course to the end of the implementation of the protocol. In view of the negative impact of pressure ulcers, it is important to have an effective and evidence-based pressure ulcer prevention programme to improve preventive care in private for-profit nursing homes. The programme will potentially improve the knowledge and skills of care staff on the prevention of pressure ulcers and also lead to a reduction in the development of pressure ulcers in nursing homes. The Current Controlled Trial is NCT02270385, 18 October 2014.
Su, Junjing; Manisty, Charlotte; Simonsen, Ulf; Howard, Luke S; Parker, Kim H; Hughes, Alun D
2017-10-15
Wave travel plays an important role in cardiovascular physiology. However, many aspects of pulmonary arterial wave behaviour remain unclear. Wave intensity and reservoir-excess pressure analyses were applied in the pulmonary artery in subjects with and without pulmonary hypertension during spontaneous respiration and dynamic stress tests. Arterial wave energy decreased during expiration and Valsalva manoeuvre due to decreased ventricular preload. Wave energy also decreased during handgrip exercise due to increased heart rate. In pulmonary hypertension patients, the asymptotic pressure at which the microvascular flow ceases, the reservoir pressure related to arterial compliance and the excess pressure caused by waves increased. The reservoir and excess pressures decreased during Valsalva manoeuvre but remained unchanged during handgrip exercise. This study provides insights into the influence of pulmonary vascular disease, spontaneous respiration and dynamic stress tests on pulmonary artery wave propagation and reservoir function. Detailed haemodynamic analysis may provide novel insights into the pulmonary circulation. Therefore, wave intensity and reservoir-excess pressure analyses were applied in the pulmonary artery to characterize changes in wave propagation and reservoir function during spontaneous respiration and dynamic stress tests. Right heart catheterization was performed using a pressure and Doppler flow sensor tipped guidewire to obtain simultaneous pressure and flow velocity measurements in the pulmonary artery in control subjects and patients with pulmonary arterial hypertension (PAH) at rest. In controls, recordings were also obtained during Valsalva manoeuvre and handgrip exercise. The asymptotic pressure at which the flow through the microcirculation ceases, the reservoir pressure related to arterial compliance and the excess pressure caused by arterial waves increased in PAH patients compared to controls. The systolic and diastolic rate constants also increased, while the diastolic time constant decreased. The forward compression wave energy decreased by ∼8% in controls and ∼6% in PAH patients during expiration compared to inspiration, while the wave speed remained unchanged throughout the respiratory cycle. Wave energy decreased during Valsalva manoeuvre (by ∼45%) and handgrip exercise (by ∼27%) with unaffected wave speed. Moreover, the reservoir and excess pressures decreased during Valsalva manoeuvre but remained unaltered during handgrip exercise. In conclusion, reservoir-excess pressure analysis applied to the pulmonary artery revealed distinctive differences between controls and PAH patients. Variations in the ventricular preload and afterload influence pulmonary arterial wave propagation as demonstrated by changes in wave energy during spontaneous respiration and dynamic stress tests. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
The effects of hindlimb unweighting on the capacitance of rat small mesenteric veins
NASA Technical Reports Server (NTRS)
Dunbar, S. L.; Berkowitz, D. E.; Brooks-Asplund, E. M.; Shoukas, A. A.
2000-01-01
Microgravity is associated with an impaired cardiac output response to orthostatic stress. Mesenteric veins are critical in modulating cardiac filling through venoconstriction. The purpose of this study was to determine the effects of simulated microgravity on the capacitance of rat mesenteric small veins. We constructed pressure-diameter relationships from vessels of 21-day hindlimb-unweighted (HLU) rats and control rats by changing the internal pressure and measuring the external diameter. Pressure-diameter relationships were obtained both before and after stimulation with norepinephrine (NE). The pressure-diameter curves of HLU vessels were shifted to larger diameters than control vessels. NE (10(-4) M) constricted veins from control animals such that the pressure-diameter relationship was significantly shifted downward (i.e., to smaller diameters at equal pressure). NE had no effect on vessels from HLU animals. These results indicate that, after HLU, unstressed vascular volume may be increased and can no longer decrease in response to sympathetic stimulation. This may partially underlie the mechanism leading to the exaggerated fall in cardiac output and stroke volume seen in astronauts during an orthostatic stress after exposure to microgravity.
Heterogeneity, pore pressure, and injectate chemistry: Control measures for geologic carbon storage
Dewers, Thomas; Eichhubl, Peter; Ganis, Ben; ...
2017-11-28
Desirable outcomes for geologic carbon storage include maximizing storage efficiency, preserving injectivity, and avoiding unwanted consequences such as caprock or wellbore leakage or induced seismicity during and post injection. Here, to achieve these outcomes, three control measures are evident including pore pressure, injectate chemistry, and knowledge and prudent use of geologic heterogeneity. Field, experimental, and modeling examples are presented that demonstrate controllable GCS via these three measures. Observed changes in reservoir response accompanying CO 2 injection at the Cranfield (Mississippi, USA) site, along with lab testing, show potential for use of injectate chemistry as a means to alter fracture permeabilitymore » (with concomitant improvements for sweep and storage efficiency). Further control of reservoir sweep attends brine extraction from reservoirs, with benefit for pressure control, mitigation of reservoir and wellbore damage, and water use. State-of-the-art validated models predict the extent of damage and deformation associated with pore pressure hazards in reservoirs, timing and location of networks of fractures, and development of localized leakage pathways. Experimentally validated geomechanics models show where wellbore failure is likely to occur during injection, and efficiency of repair methods. Use of heterogeneity as a control measure includes where best to inject, and where to avoid attempts at storage. Lastly, an example is use of waste zones or leaky seals to both reduce pore pressure hazards and enhance residual CO 2 trapping.« less
Heterogeneity, pore pressure, and injectate chemistry: Control measures for geologic carbon storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewers, Thomas; Eichhubl, Peter; Ganis, Ben
Desirable outcomes for geologic carbon storage include maximizing storage efficiency, preserving injectivity, and avoiding unwanted consequences such as caprock or wellbore leakage or induced seismicity during and post injection. Here, to achieve these outcomes, three control measures are evident including pore pressure, injectate chemistry, and knowledge and prudent use of geologic heterogeneity. Field, experimental, and modeling examples are presented that demonstrate controllable GCS via these three measures. Observed changes in reservoir response accompanying CO 2 injection at the Cranfield (Mississippi, USA) site, along with lab testing, show potential for use of injectate chemistry as a means to alter fracture permeabilitymore » (with concomitant improvements for sweep and storage efficiency). Further control of reservoir sweep attends brine extraction from reservoirs, with benefit for pressure control, mitigation of reservoir and wellbore damage, and water use. State-of-the-art validated models predict the extent of damage and deformation associated with pore pressure hazards in reservoirs, timing and location of networks of fractures, and development of localized leakage pathways. Experimentally validated geomechanics models show where wellbore failure is likely to occur during injection, and efficiency of repair methods. Use of heterogeneity as a control measure includes where best to inject, and where to avoid attempts at storage. Lastly, an example is use of waste zones or leaky seals to both reduce pore pressure hazards and enhance residual CO 2 trapping.« less
Check valve installation in pilot operated relief valve prevents reverse pressurization
NASA Technical Reports Server (NTRS)
Oswalt, L.
1966-01-01
Two check valves prevent reverse flow through pilot-operated relief valves of differential area piston design. Title valves control pressure flow to ensure that the piston dome pressure is always at least as great as the main relief valve discharge pressure.
Piek, J; Raes, P
1996-01-01
We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.
Aortic baroreflex control of heart rate after 15 days of simulated microgravity exposure
NASA Technical Reports Server (NTRS)
Crandall, Craig G.; Engelke, Keith A.; Convertino, Victor A.; Raven, Peter B.
1994-01-01
To determine the effects of simulated microgravity on aortic baroreflex control of heart rate, we exposed seven male subjects to 15 days of bed rest in the 6 deg head-down position. The sensitivity of the aortic-cardiac baroreflex was determined during a steady-state phenylephrine-induced increase in mean arterial pressure combined with lower body negative pressure to counteract central venous pressure increases and neck pressure to offset the increased carotid sinus transmural pressure. The aortic-cardiac baroreflex gain was assessed by determining the ratio of the change in heart rate to the change in mean arterial pressure between baseline conditions and aortic baroreceptor-isolated conditions (i.e., phenylephrine + lower body negative pressure + neck pressure stage). Fifteen days of head-down tilt increased the gain of the aortic-cardiac baroreflex. Reductions in blood volume and/or maximal aerobic capacity may represent the underlying mechanism(s) responsible for increased aortic baroreflex responsiveness after exposure to a ground-based analogue of microgravity.
Pressure Response of Various Gases in a Pneumatic Resistance Capacitance System and Pipe
NASA Astrophysics Data System (ADS)
Peng, J.; Youn, C.; Tadano, K.; Kagawa, T.
2017-10-01
City gas, such as propane and methane, is widely used as a fuel in households and factories. Recently, hydrogen as a clean and efficient fuel has been proposed for fuel cell vehicles. However, few studies have investigated pressure control and response of gases considering their properties. This study investigated the static flow rate characteristics in an orifice with four gases—air, propane, methane, and hydrogen. Then, a pressure response experiment was performed using a pneumatic resistance capacitance system comprising an isothermal chamber and a nozzle flapper, and the time constant of the pressure response with various gases was analysed with a mathematical model. The simulation results agreed with the experimental data. Finally, the differences in pressure propagation in a pipe with various gases were explicated by a pressure response experiment. The results showed that the pressure response speed of hydrogen is faster than that of the other three gases because of its small molecular weight. Therefore, the pressure control equipment of hydrogen needs a high response speed.
Effect of Gas Pressure on Polarization of SOFC Cathode Prepared by Plasma Spray
NASA Astrophysics Data System (ADS)
Li, Cheng-Xin; Wang, Zhun-Zhun; Liu, Shuai; Li, Chang-Jiu
2013-06-01
A cermet-supported tubular SOFC was fabricated using thermal spray. The cell performance was investigated at temperatures from 750 to 900 °C and pressures from 0.1 to 0.5 MPa to examine the effect of operating gas pressure on the cell performance. The influence of gas pressure on the cathodic polarization was studied through the electrochemical impedance approach to examine the controlling electrochemical processes during cell operation. Results show that increasing the operating gas pressure improves the power output performance significantly. When the gas pressure is increased from 0.1 to 0.3 MPa, the maximum power density is increased by a factor of 32% at a temperature of 800 °C. The cathode polarization decreases significantly with the increase of the gas pressure. The electrochemical analysis shows that the main control processes of the cathode reaction are the oxygen species transfer at the three-phase boundary and oxygen diffusion on the surface or in the bulk of the cathode, which are enhanced with increasing gas pressure.
Low Blood Pressure (Hypotension)
... Low blood pressure on standing up (orthostatic, or postural, hypotension). This is a sudden drop in blood ... progressive damage to the autonomic nervous system, which controls involuntary functions such as blood pressure, heart rate, ...
Value and limitations of transpulmonary pressure calculations during intra-abdominal hypertension.
Cortes-Puentes, Gustavo A; Gard, Kenneth E; Adams, Alexander B; Faltesek, Katherine A; Anderson, Christopher P; Dries, David J; Marini, John J
2013-08-01
To clarify the effect of progressively increasing intra-abdominal pressure on esophageal pressure, transpulmonary pressure, and functional residual capacity. Controlled application of increased intra-abdominal pressure at two positive end-expiratory pressure levels (1 and 10 cm H2O) in an anesthetized porcine model of controlled ventilation. Large animal laboratory of a university-affiliated hospital. Eleven deeply anesthetized swine (weight 46.2 ± 6.2 kg). Air-regulated intra-abdominal hypertension (0-25 mm Hg). Esophageal pressure, tidal compliance, bladder pressure, and end-expiratory lung aeration by gas dilution. Functional residual capacity was significantly reduced by increasing intra-abdominal pressure at both positive end-expiratory pressure levels (p ≤ 0.0001) without corresponding changes of end-expiratory esophageal pressure. Above intra-abdominal pressure 5 mm Hg, plateau airway pressure increased linearly by ~ 50% of the applied intra-abdominal pressure value, associated with commensurate changes of esophageal pressure. With tidal volume held constant, negligible changes occurred in transpulmonary pressure due to intra-abdominal pressure. Driving pressures calculated from airway pressures alone (plateau airway pressure--positive end-expiratory pressure) did not equate to those computed from transpulmonary pressure (tidal changes in transpulmonary pressure). Increasing positive end-expiratory pressure shifted the predominantly negative end-expiratory transpulmonary pressure at positive end-expiratory pressure 1 cm H2O (mean -3.5 ± 0.4 cm H2O) into the positive range at positive end-expiratory pressure 10 cm H2O (mean 0.58 ± 1.2 cm H2O). Despite its insensitivity to changes in functional residual capacity, measuring transpulmonary pressure may be helpful in explaining how different levels of positive end-expiratory pressure influence recruitment and collapse during tidal ventilation in the presence of increased intra-abdominal pressure and in calculating true transpulmonary driving pressure (tidal changes of transpulmonary pressure). Traditional interpretations of respiratory mechanics based on unmodified airway pressure were misleading regarding lung behavior in this setting.
New pressure control method of mixed gas in a combined cycle power plant of a steel mill
NASA Astrophysics Data System (ADS)
Xie, Yudong; Wang, Yong
2017-08-01
The enterprise production concept is changing with the development of society. A steel mill requires a combined-cycle power plant, which consists of both a gas turbine and steam turbine. It can recycle energy from the gases that are emitted from coke ovens and blast furnaces during steel production. This plant can decrease the overall energy consumption of the steel mill and reduce pollution to our living environment. To develop a combined-cycle power plant, the pressure in the mixed-gas transmission system must be controlled in the range of 2.30-2.40 MPa. The particularity of the combined-cycle power plant poses a challenge to conventional controllers. In this paper, a composite control method based on the Smith predictor and cascade control was proposed for the pressure control of the mixed gases. This method has a concise structure and can be easily implemented in actual industrial fields. The experiment has been conducted to validate the proposed control method. The experiment illustrates that the proposed method can suppress various disturbances in the gas transmission control system and sustain the pressure of the gas at the desired level, which helps to avoid abnormal shutdowns in the combined-cycle power plant.
Uzeda, Marcelo José; Moura, Brenda; Louro, Rafael Seabra; da Silva, Licínio Esmeraldo; Calasans-Maia, Mônica Diuana
2014-05-01
The control of hypertensive patients' blood pressure and heart rate using vasoconstrictors during surgical procedures under anesthesia is still a major concern in everyday surgical practice. This clinical trial aimed to evaluate the variation of blood pressure and heart rate in nonhypertensive and controlled hypertensive voluntary subjects undergoing oral surgery under local anesthesia with lidocaine hydrochloride and epinephrine at 1:100,000 (Alphacaine; DFL, Brazil), performed in the Oral Surgery Department, Dentistry School, Fluminense Federal University. In total, 25 voluntary subjects were divided into 2 groups: nonhypertensive (n = 15) and controlled hypertensives (n = 10). Blood pressure and heart rate were measured at 4 different times: T0, in the waiting room; T1, after placement of the surgical drapes; T2, 10 minutes after anesthesia injection; and T3, at the end of the surgical procedure. A statistically significant difference (P < 0.05) between the groups was found at times T0 and T2 for the systolic pressure but only at time T0 for the diastolic pressure. The assessment of the heart rate of both groups showed a statistically significant difference (P < 0.05) at time T1. An analysis of the employed anesthetic volume indicated no statistically significant difference (P > 0.05) between the amount administered to nonhypertensive and hypertensive subjects. It was concluded that the local anesthetics studied could safely be used in controlled hypertensive and nonhypertensive patients in compliance with the maximum recommended doses.
Hayashino, Yasuaki; Jackson, Jeffrey L; Fukumori, Norio; Nakamura, Fumiaki; Fukuhara, Shunichi
2012-12-01
Our study's purpose was to perform a systematic review to assess the effect of supervised exercise interventions on lipid profiles and blood pressure control. We searched electronic databases and selected studies that evaluated the effect of supervised exercise intervention on cardiovascular risk factors in adult people with type 2 diabetes. We used random effect models to derive weighted mean differences of exercise on lipid profiles and blood pressure control. Forty-two RCTs (2808 subjects) met inclusion criteria and are included in our meta-analysis. Structured exercise was associated with a change in systolic blood pressure (SBP) of -2.42 mmHg (95% CI, -4.39 to -0.45 mmHg), diastolic blood pressure (DBP) of -2.23 mmHg (95% CI, -3.21 to -1.25 mmHg), high-density lipoprotein cholesterol (HDL-C) of 0.04 mmol/L (95% CI, 0.02-0.07 mmol/L), and low-density lipoprotein cholesterol (LDL-C) of -0.16 mmol/L (95% CI, -0.30 to -0.01 mmol/L). Heterogeneity was partially explained by age, dietary co-intervention and the duration and intensity of the exercise. Supervised exercise is effective in improving blood pressure control, lowering LDL-C, and elevating HDL-C levels in people with diabetes. Physicians should recommend exercise for their adult patients with diabetes who can safely do so. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Maturation of heart rate and blood pressure variability during sleep in term-born infants.
Yiallourou, Stephanie R; Sands, Scott A; Walker, Adrian M; Horne, Rosemary S C
2012-02-01
Abnormal blood pressure control is implicated in the sudden infant death syndrome (SIDS). However, no data exist on normal development of blood pressure control during infancy. This study assessed maturation of autonomic control of blood pressure and heart rate during sleep within the first 6 months of life. Term infants (n = 31) were studied longitudinally at 2-4 weeks, 2-3 months, and 5-6 months postnatal age. Infants underwent daytime polysomnography at each age studied. Blood pressure and heart rate were recorded during quiet (QS) and active (AS) sleep in undisturbed baseline and head-up tilt conditions. Autonomic control was assessed using spectral indices of blood pressure and heart rate variability (BPV and HRV) in ranges of low frequency (LF, reflecting sympathetic + parasympathetic activity) and high frequency (HF, parasympathetic activity), total power (LF+HF), and LF/HF ratio (sympathovagal balance). With increasing postnatal age and predominantly during QS, HRV-LF, HRV-HF, and HRV total power increased, while HRV-LF/HF decreased. BPV-LF/HF also decreased with postnatal age. All changes were evident in both baseline and head-up tilt conditions. BPV-LF and BPV total power during tilts were markedly reduced in QS versus AS at each age. In sleeping infants, sympathetic vascular modulation of the circulation decreases with age, while parasympathetic control of heart rate is strengthened. These normative data will aid in the early identification of conditions where autonomic function is impaired, such as in SIDS.
Lourenco, L; Blanes, L; Salomé, G M; Ferreira, L M
2014-06-01
To evaluate health-related quality of life (HRQoL) and self-esteem in patients with traumatic spinal cord injury (SCI) and pressure ulcers. This study was a controlled cross-sectional study. HRQoL was assessed using the generic Medical Outcomes Study 36-Item Short Form Health Survey (SF-36) questionnaire and the Rosenberg Self-Esteem/UNIFESP-EPM Scale. A total of 120 patients with traumatic SCI were included in the sample, of which 60 had pressure ulcers and were assigned to the study group, and 60 had no pressure ulcers and were assigned to the control group. Statistical analysis was performed using the chi-square test, Fisher's exact test, and Student's t-test. Of the 60 patients in the study group, 83.3% were men and the mean age was 38.17 years (SD = 9.08 years). When compared with controls, patients in the study group reported significantly lower scores (worse health status) on all SF-36 subscales (p less than or equal to 0.0013) except for general health (p=0.109). The RSE/UNIFESP-EMP scale total score indicated that patients with pressure ulcers had significantly lower self-esteem than controls (p<0.001). Pressure ulcers had an adverse impact on the HRQoL and self-esteem of patients with SCI. There were no external sources of funding for this study. The authors have no conflicts of interest to declare.
Forni, Cristiana; D'Alessandro, Fabio; Gallerani, Pina; Genco, Rossana; Bolzon, Andrea; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Vitulli, Arianna; Amodeo, Alfredo; Celli, Guglielmo; Taddia, Patrizia
2018-06-01
Hip fractures in the elderly are a serious problem for the health service due to the high rate of complications. One of these complications is pressure ulcers that, according to the literature, occur in 8.8% to 55% of patients and mainly arise in the sacral area. The present randomised controlled trial tests whether applying a new innovative multi-layer polyurethane foam dressing (ALLEVYN LIFE™), reduces the onset of pressure ulcers in the sacral area. From March to December 2016, 359 fragility hip fracture patients were randomly divided into 2 groups: 182 in the control group and 177 in the experimental group. Pressure ulcers occurred overall in 36 patients (10%): 8 patients (4.5%) in the experimental group compared to 28 (15.4%) in the control group: P = 0.001, relative risk 0.29 (95% CI 0.14-0.61) with NNT of 9 (95% CI 6-21). In the experimental group the onset of pressure ulcers occurred on average on the 6th day compared to the 4th day in the control group (HR 4.4). Using polyurethane foam is effective at reducing the rate of pressure ulcers in the sacrum in elderly patients with hip fracture. The adhesiveness of this device also enables costs to be kept down. © 2018 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Effect of home telehealth care on blood pressure control: A public healthcare centre model.
Lu, Ju-Fen; Chen, Ching-Min; Hsu, Chien-Yeh
2017-01-01
Objective This study aimed to evaluate the effectiveness of home telehealth care combined with case management by public health nurses, in improving blood pressure control in patients with hypertension. Methods This cohort study examined the data of patients with hypertension obtained from a telehealth service centre database, between July 2011- June 2012. Eligible patients were adults (≥40 years old) with both prehypertension and hypertension, living alone or in the remote suburbs of metropolitan areas. Demographic data were collected from 12 district public health centre in Taipei, Taiwan. Following enrolment, patients received an appropriate and validated home telehealth device kit for automatic blood pressure monitoring and automated modem via a telephone line or a desktop computer with Internet connection to enable data transmission between the patient's home and telehealth service centre. Patients were instructed to upload the measured data immediately every day. The study outcomes included blood pressure and home telehealth service utilisation. Results Of the 432 patients recruited, 408 (94%) completed data collection. Linear regression analysis found an average 22.1 mm Hg reduction in systolic blood pressure after one year. The mean slope of systolic blood pressure was classified as decreased or non-decreased. An systolic blood pressure decreasing trend was observed in 52.2% patients, while 47.8% patients showed an increasing systolic blood pressure trend. Patients in the decreased systolic blood pressure group tended to be older ( p = 0. 0001), with a greater proportion of hypertension alarms ( p = 0. 001), improved self-blood pressure monitoring behaviour ( p = 0.009) and higher self-measured blood pressure monitoring frequency ( p = 0. 010). Patients in the decreased systolic blood pressure group had a higher self-measured blood pressure monitoring frequency (odds ratio = 0.95, 95% confidence interval, 0.91-0.99, p = 0. 013) than their counterparts. Conclusions Home telehealth care combined with care management by public health nurses based in public health care centre was feasible and effective for improving blood pressure control among patients with hypertension. Further studies should conduct a thorough analysis of the cost-effectiveness of this intervention. A randomised controlled trial with a longer follow-up period is required to examine the effects of the improved home telehealth device kit on the care of patients with hypertension.
112. REFRIGERANT CONDENSER TANKS AND PRESSURE CONTROLS IN NORTHEAST CORNER ...
112. REFRIGERANT CONDENSER TANKS AND PRESSURE CONTROLS IN NORTHEAST CORNER OF MECHANICAL EQUIPMENT ROOM (201), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
NASA Technical Reports Server (NTRS)
Webb, J. A., Jr.
1974-01-01
The multipurpose ventricular actuating system is a pneumatic signal generating device that provides controlled driving pressures for actuating pulsatile blood pumps. Overall system capabilities, the timing circuitry, and calibration instruction are included.
Speed control with end cushion for high speed air cylinder
Stevens, Wayne W.; Solbrig, Charles W.
1991-01-01
A high speed air cylinder in which the longitudinal movement of the piston within the air cylinder tube is controlled by pressurizing the air cylinder tube on the accelerating side of the piston and releasing pressure at a controlled rate on the decelerating side of the piston. The invention also includes a method for determining the pressure required on both the accelerating and decelerating sides of the piston to move the piston with a given load through a predetermined distance at the desired velocity, bringing the piston to rest safely without piston bounce at the end of its complete stroke.
Control apparatus for hot gas engine
Stotts, Robert E.
1986-01-01
A mean pressure power control system for a hot gas (Stirling) engine utilizing a plurality of supply tanks for storing a working gas at different pressures. During pump down operations gas is bled from the engine by a compressor having a plurality of independent pumping volumes. In one embodiment of the invention, a bypass control valve system allows one or more of the compressor volumes to be connected to the storage tanks. By selectively sequencing the bypass valves, a capacity range can be developed over the compressor that allows for lower engine idle pressures and more rapid pump down rates.
Jet mixing in low gravity - Results of the Tank Pressure Control Experiment
NASA Technical Reports Server (NTRS)
Bentz, M. D.; Meserole, J. S.; Knoll, R. H.
1992-01-01
The Tank Pressure Control Experiment (TPCE) is discussed with attention given to the results for controlling storage-tank pressures by forced-convective mixing in microgravitational environments. The fluid dynamics of cryogenic fluids in space is simulated with freon-113 during axial-jet-induced mixing. The experimental flow-pattern data are found to confirm previous data as well as existing mixing correlations. Thermal nonuniformities and tank pressure can be reduced by employing low-energy mixing jets which are useful for enhancing heat/mass transfer between phases. It is found that space cryogenic systems based on the principle of active mixing can be more reliable and predictable than other methods, and continuous or periodic mixing can be accomplished with only minor energy addition to the fluid.
Application of active control landing gear technology to the A-10 aircraft
NASA Technical Reports Server (NTRS)
Ross, I.; Edson, R.
1983-01-01
Two concepts which reduce the A-10 aircraft's wing/gear interface forces as a result of applying active control technology to the main landing gear are described. In the first concept, referred to as the alternate concept a servovalve in a closed pressure control loop configuration effectively varies the size of the third stage spool valve orifice which is embedded in the strut. This action allows the internal energy in the strut to shunt hydraulic flow around the metering orifice. The command signal to the loop is reference strut pressure which is compared to the measured strut pressure, the difference being the loop error. Thus, the loop effectively varies the spool valve orifice size to maintain the strut pressure, and therefore minimizes the wing/gear interface force referenced.
NASA Technical Reports Server (NTRS)
Mccain, W. E.
1984-01-01
The unsteady aerodynamic lifting surface theory, the Doublet Lattice method, with experimental steady and unsteady pressure measurements of a high aspect ratio supercritical wing model at a Mach number of 0.78 were compared. The steady pressure data comparisons were made for incremental changes in angle of attack and control surface deflection. The unsteady pressure data comparisons were made at set angle of attack positions with oscillating control surface deflections. Significant viscous and transonic effects in the experimental aerodynamics which cannot be predicted by the Doublet Lattice method are shown. This study should assist development of empirical correction methods that may be applied to improve Doublet Lattice calculations of lifting surface aerodynamics.
Fincke, James R.
2003-09-23
Oil field management systems and methods for managing operation of one or more wells producing a high void fraction multiphase flow. The system includes a differential pressure flow meter which samples pressure readings at various points of interest throughout the system and uses pressure differentials derived from the pressure readings to determine gas and liquid phase mass flow rates of the high void fraction multiphase flow. One or both of the gas and liquid phase mass flow rates are then compared with predetermined criteria. In the event such mass flow rates satisfy the predetermined criteria, a well control system implements a correlating adjustment action respecting the multiphase flow. In this way, various parameters regarding the high void fraction multiphase flow are used as control inputs to the well control system and thus facilitate management of well operations.
A regulator for pressure-controlled total-liquid ventilation.
Robert, Raymond; Micheau, Philippe; Avoine, Olivier; Beaudry, Benoit; Beaulieu, Alexandre; Walti, Hervé
2010-09-01
Total-liquid ventilation (TLV) is an innovative experimental method of mechanical-assisted ventilation in which lungs are totally filled and then ventilated with a tidal volume of perfluorochemical liquid by using a dedicated liquid ventilator. Such a novel medical device must resemble other conventional ventilators: it must be able to conduct controlled-pressure ventilation. The objective was to design a robust controller to perform pressure-regulated expiratory flow and to implement it on our latest liquid-ventilator prototype (Inolivent-4). Numerical simulations, in vitro experiments, and in vivo experiments in five healthy term newborn lambs have demonstrated that it was efficient to generate expiratory flows while avoiding collapses. Moreover, the in vivo results have demonstrated that our liquid ventilator can maintain adequate gas exchange, normal acid-base equilibrium, and achieve greater minute ventilation, better oxygenation and CO2 extraction, while nearing flow limits. Hence, it is our suggestion to perform pressure-controlled ventilation during expiration with minute ventilation equal or superior to 140 mL x min(-1) x kg(-1) in order to ensure PaCO2 below 55 mmHg. From a clinician's point of view, pressure-controlled ventilation greatly simplifies the use of the liquid ventilator, which will certainly facilitate its introduction in intensive care units for clinical applications.
Frequency-dependent baroreflex control of blood pressure and heart rate during physical exercise.
Spadacini, Giammario; Passino, Claudio; Leuzzi, Stefano; Valle, Felice; Piepoli, Massimo; Calciati, Alessandro; Sleight, Peter; Bernardi, Luciano
2006-02-15
It is widely recognised that during exercise vagal heart rate control is markedly impaired but blood pressure control may or may not be retained. We hypothesised that this uncertainty arose from the differing responses of the vagus (fast) and sympathetic (slow) arms of the autonomic effectors, and to differing sympatho-vagal balance at different exercise intensities. We studied 12 normals at rest, during moderate (50% maximal heart rate) and submaximal (80% maximal heart rate) exercise. The carotid baroreceptors were stimulated by sinusoidal neck suction at the frequency of the spontaneous high- (during moderate exercise) and low-frequency (during submaximal) fluctuations in heart period and blood pressure. The increases in these oscillations induced by neck suction were measured by autoregressive spectral analysis. At rest neck stimulation increased variability at low frequency (RR: from 6.99+/-0.24 to 8.87+/-0.18 ln-ms2; systolic pressure: from 3.05+/-1.7 to 4.09+/-0.17 ln-mm Hg2) and high frequency (RR: from 4.67+/-0.25 to 6.79+/-0.31 ln-ms2; systolic pressure: from 1.93+/-0.2 to 2.67+/-0.125 ln-mm Hg2) (all p<0.001). During submaximal exercise RR variability decreased but systolic pressure variability rose (p<0.01 vs rest); during submaximal exercise low-frequency neck stimulation increased the low-frequency fluctuations in blood pressure (2.35+/-0.51 to 4.25+/-0.38 ln-mm Hg2, p<0.05) and RR. Conversely, neck suction at high frequency was ineffective on systolic pressure, and had only minor effects on RR interval during moderate exercise. During exercise baroreflex control is active on blood pressure, but the efferent response on blood pressure and heart rate is only detected during low frequency stimulation, indicating a frequency-dependent effect.
Makhsous, Mohsen; Lin, Fang; Knaus, Evan; Zeigler, Mary; Rowles, Diane M; Gittler, Michelle; Bankard, James; Chen, David
2009-11-01
To evaluate whether an individualized cyclic pressure-relief protocol accelerates wound healing in wheelchair users with established pressure ulcers (PrUs). Randomized controlled study. Spinal cord injury clinics. Forty-four subjects, aged 18-79 years, with a Stage II or Stage III PrU, were randomly assigned to the control (n = 22) or treatment (n = 22) groups. Subjects in the treatment group used wheelchairs equipped with an individually adjusted automated seat that provided cyclic pressure relief, and those in the control group used a standard wheelchair. All subjects sat in wheelchairs for a minimum of 4 hours per day for 30 days during their PrU treatment. Wound characteristics were assessed using the Pressure Ulcer Scale for Healing (PUSH) tool and wound dimensions recorded with digital photographs twice a week. Median healing time for a 30% healing relative to initial measurements, the percentage reduction in wound area, and the percentage improvement in PUSH score achieved at the end of the trial were compared between groups. At the end of 30 days, both groups demonstrated a general trend of healing. However, the treatment group was found to take significantly less time to achieve 30% healing for the wound measurement compared with the control group. The percentage improvement of the wound area and PUSH scores were greater in using cyclic seating (45.0 +/- 21.0, P < .003; 29.9 +/- 24. 6, P < .003) compared with standard seating (10.2 +/- 34.9, 5.8 +/- 9.2). The authors' findings show that cyclically relieving pressure in the area of a wound for seated individuals can greatly aid wound healing. The current study provides evidence that the individualized cyclic pressure-relief protocol helps promote pressure wound healing in a clinical setting. The authors concluded that the individualized cyclic pressure relief may have substantial benefits in accelerating the healing process in wheelchair users with existing PrUs, while maintaining the mobility of individuals with SCI during the PrU treatment.
Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi
2017-09-15
In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.
Neural control of vascular reactions: impact of emotion and attention.
Okon-Singer, Hadas; Mehnert, Jan; Hoyer, Jana; Hellrung, Lydia; Schaare, Herma Lina; Dukart, Juergen; Villringer, Arno
2014-03-19
This study investigated the neural regions involved in blood pressure reactions to negative stimuli and their possible modulation by attention. Twenty-four healthy human subjects (11 females; age = 24.75 ± 2.49 years) participated in an affective perceptual load task that manipulated attention to negative/neutral distractor pictures. fMRI data were collected simultaneously with continuous recording of peripheral arterial blood pressure. A parametric modulation analysis examined the impact of attention and emotion on the relation between neural activation and blood pressure reactivity during the task. When attention was available for processing the distractor pictures, negative pictures resulted in behavioral interference, neural activation in brain regions previously related to emotion, a transient decrease of blood pressure, and a positive correlation between blood pressure response and activation in a network including prefrontal and parietal regions, the amygdala, caudate, and mid-brain. These effects were modulated by attention; behavioral and neural responses to highly negative distractor pictures (compared with neutral pictures) were smaller or diminished, as was the negative blood pressure response when the central task involved high perceptual load. Furthermore, comparing high and low load revealed enhanced activation in frontoparietal regions implicated in attention control. Our results fit theories emphasizing the role of attention in the control of behavioral and neural reactions to irrelevant emotional distracting information. Our findings furthermore extend the function of attention to the control of autonomous reactions associated with negative emotions by showing altered blood pressure reactions to emotional stimuli, the latter being of potential clinical relevance.
de la Sierra, Alejandro; Gorostidi, Manuel; Aranda, Pedro; Corbella, Emili; Pintó, Xavier
2015-07-01
To assess the prevalence of atherogenic dyslipidemia in hypertensive patients and its relationship with risk profile and blood pressure control. The study included 24 351 hypertensive patients from the Spanish Ambulatory Blood Pressure Monitoring Registry. Atherogenic dyslipidemia was defined as the presence of hypertriglyceridemia (> 150mg/dL) and low levels of high-density lipoprotein cholesterol (< 40mg/dL in men and < 46mg/dL in women). Blood pressure control was assessed by office and ambulatory monitoring. Atherogenic dyslipidemia was present in 2705 patients (11.1%). Of these, 30% had hypertriglyceridemia and 21.7% had low levels of high-density lipoprotein cholesterol. Compared with patients without these risk factors, the former group were more often male (60% vs 52%), younger (57 years vs 59 years), had other risk factors and organ damage (microalbuminuria, reduced estimated glomerular filtration rate, and left ventricular hypertrophy), worse office, diurnal, and nocturnal blood pressure values (odds ratio 1.09, 1.06, and 1.10, respectively), and the lowest nocturnal blood pressure reduction (odds ratio=1.07), despite the greater use of antihypertensive drugs. Atherogenic dyslipidemia is present in more than 10% of hypertensive patients and is associated with other risk factors, organ damage, and poorer blood pressure control. Greater therapeutic effort is needed to reduce overall risk in these patients. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Vidal, Patricia N.; Miceli, Diego D.; Arias, Elber Soler; D’Anna, Elena; García, Jorge D.; Castillo, Victor Alejandro
2018-01-01
Hyperadrenocorticism is a frequent disease in dogs. The excess of circulating cortisol affects different organs and metabolic pathways, producing severe adverse effects that endanger the animal’s life. Among these effects, hypertension and renal damage can be mentioned. A group of 20 dogs with pituitary dependent hyperadrenocorticism (PDH) and 12 control dogs were used to study the following parameters: cortisol and nitric oxide (NO nit/nit) concentrations, diastolic and systolic blood pressure, renal artery resistance index by Doppler ultrasound, the rate of glomerular filtration by radio-renogram excretion and the presence of proteins in urine. Dogs with PDH showed a significantly lower NO nit/nit (P<0.0001) than the controls and this correlated with high values of diastolic and systolic pressure (r = -0.87; P<0.0001 and r = -0.81; P<0.0001 respectively). Most dogs (80%) are hypertensive mainly due to an increase in diastolic pressure, which correlated positively with the UPC (r = 0.8; P<0.001) and negatively with the glomerular rate of filtration (r = -0.58; P=0.007). Systolic pressure only increased in 60% of the cases and did not correlate with the mentioned variables. In PDH the decrease of NO affects blood pressure. The diastolic pressure would seem to have the greatest impact on the kidneys, therefore its evaluation and control are important to avoid and/or control renal damage. PMID:29721437
Nakagami, Gojiro; Sanada, Hiromi; Konya, Chizuko; Kitagawa, Atsuko; Tadaka, Etsuko; Matsuyama, Yutaka
2007-09-01
This paper is a report of an evaluation of the effectiveness of a newly developed dressing for preventing persistent erythema and pressure ulcer development and improving the water-holding capacity without increasing the skin pH in bedridden older patients. Shear forces and skin dryness play important roles in persistent erythema and pressure ulcer development. To eliminate these risks, we developed a dressing to reduce shear forces and improve the water-holding capacity. However, the effects of this dressing in clinical settings remain unknown. An experimental bilateral comparison study was conducted at a hospital in Japan in 2004 with 37 bedridden older patients at risk of pressure ulcer development. The dressing was randomly applied to the right or left greater trochanter for 3 weeks. No dressing was applied to the opposite side as a control. The skin was monitored weekly during the 3-week application for persistent erythema and pressure ulcer development. Skin hydration and pH were also assessed during the intervention and for 1 week after dressing removal. The incidence of persistent erythema was significantly lower in the intervention area than the control area [P = 0.007, RR 0.18 (95% CI: 0.05-0.73) and NNT 4.11 (2.50-11.63) ]. No pressure ulcers occurred in either the intervention or control area. Skin hydration increased significantly during dressing application and remained high after removal (P < 0.001) relative to the control area. Skin pH decreased significantly during the application (P < 0.001) but returned to control levels after removal (P = 0.38). This safe and effective dressing can be used for patients with highly prominent bones and dry skin to prevent pressure ulcers.
Blackstone, Sarah; Iwelunmor, Juliet; Plange-Rhule, Jacob; Gyamfi, Joyce; Quakyi, Nana Kofi; Ntim, Micheal; Addison, Abigail; Ogedegbe, Gbenga
2017-07-04
Currently in Ghana, there is an on-going task-shifting strategy in which nurses are trained in hypertension management. While this study will provide useful information on the viability of this approach, it is not clear how patients in the intervention perceive hypertension, the task-shifting strategy, and its effects on blood pressure management. The objective of this paper is to examine patients' perceptions of hypertension and hypertension management in the context of an on-going task-shifting intervention to manage blood pressure control in Ghana. Forty-two patients participating in the Task Shifting Strategy for Hypertension program (23 males, 19 females, and mean age 61. 7 years) completed in-depth, qualitative interviews. Interviews were transcribed, and key words and phrases were extracted and coded using the PEN-3 Cultural Model as a guide through open and axial coding techniques, thus allowing rich exploration of the data. Emergent themes included patients' perceptions of hypertension, which encompassed misperceptions of hypertension and blood pressure control. Additional themes included enablers and barriers to hypertension management, and how the intervention nurtured lifestyle change associated with blood pressure control. Primary enabling factors included the supportive nature of TASSH nurses, while notable barriers were financial constraints and difficulty accessing medication. Nurturing factors included the motivational interviewing and patient counseling which instilled confidence in the patients that they could make lasting behavior changes. This study offers a unique perspective of blood pressure control by examining how patients view an on-going task-shifting initiative for hypertension management. The results of this study shed light on factors that can help and hinder individuals in low-resource settings with long-term blood pressure management.
Maturation of Heart Rate and Blood Pressure Variability during Sleep in Term-Born Infants
Yiallourou, Stephanie R.; Sands, Scott A.; Walker, Adrian M.; Horne, Rosemary S.C.
2012-01-01
Study Objectives: Abnormal blood pressure control is implicated in the sudden infant death syndrome (SIDS). However, no data exist on normal development of blood pressure control during infancy. This study assessed maturation of autonomic control of blood pressure and heart rate during sleep within the first 6 months of life. Participants: Term infants (n = 31) were studied longitudinally at 2-4 weeks, 2-3 months, and 5-6 months postnatal age. Interventions: Infants underwent daytime polysomnography at each age studied. Blood pressure and heart rate were recorded during quiet (QS) and active (AS) sleep in undisturbed baseline and head-up tilt conditions. Measurements and Results: Autonomic control was assessed using spectral indices of blood pressure and heart rate variability (BPV and HRV) in ranges of low frequency (LF, reflecting sympathetic + parasympathetic activity) and high frequency (HF, parasympathetic activity), total power (LF+HF), and LF/HF ratio (sympathovagal balance). With increasing postnatal age and predominantly during QS, HRV-LF, HRV-HF, and HRV total power increased, while HRV-LF/HF decreased. BPV-LF/HF also decreased with postnatal age. All changes were evident in both baseline and head-up tilt conditions. BPV-LF and BPV total power during tilts were markedly reduced in QS versus AS at each age. Conclusions: In sleeping infants, sympathetic vascular modulation of the circulation decreases with age, while parasympathetic control of heart rate is strengthened. These normative data will aid in the early identification of conditions where autonomic function is impaired, such as in SIDS. Citation: Yiallourou SR; Sands SA; Walker AM; Horne RSC. Maturation of heart rate and blood pressure variability during sleep in term-born infants. SLEEP 2012;35(2):177-186. PMID:22294807
Poor Long-Term Blood Pressure Control after Intracerebral Hemorrhage
Zahuranec, Darin B.; Wing, Jeffrey J.; Edwards, Dorothy F.; Menon, Ravi S.; Fernandez, Stephen J.; Burgess, Richard E.; Sobotka, Ian A.; German, Laura; Trouth, Anna J.; Shara, Nawar M.; Gibbons, M. Chris; Boden-Albala, Bernadette; Kidwell, Chelsea S.
2012-01-01
Background and Purpose Hypertension is the most important risk factor associated with intracerebral hemorrhage (ICH). We explored racial differences in blood pressure (BP) control after ICH and assessed predictors of BP control at presentation, 30 days, and 1 year in a prospective cohort study. Methods Subjects with spontaneous ICH were identified from the DiffErenCes in the Imaging of Primary Hemorrhage based on Ethnicity or Race (DECIPHER) Project. Blood pressure was compared by race at each time point. Multivariable linear regression was used to determine predictors of presenting mean arterial pressure (MAP), and longitudinal linear regression was used to assess predictors of MAP at follow-up. Results A total of 162 patients were included (mean age 59, 53% male, 77% black). MAP at presentation was 9.6 mmHg higher in blacks than whites despite adjustment for confounders (p=0.065). Fewer than 20% of patients had normal blood pressure (<120/80 mmHg) at 30 days or 1 year. While there was no difference at 30 days (p=0.331), blacks were more likely than whites to have Stage I/II hypertension at one year (p=0.036). Factors associated with lower MAP at follow-up in multivariable analysis were being married at baseline (p=0.032) and living in a facility (versus personal residence) at the time of BP measurement (p=0.023). Conclusions Long-term blood pressure control is inadequate in patients following ICH, particularly in blacks. Further studies are needed to understand the role of social support and barriers to control to identify optimal approaches to improve blood pressure in this high-risk population. PMID:22903494
High Blood Pressure in Pregnancy
... of the baby. Controlling your blood pressure during pregnancy and getting regular prenatal care are important for ... your baby. Treatments for high blood pressure in pregnancy may include close monitoring of the baby, lifestyle ...
Weightlifting: Bad for Your Blood Pressure?
... blood pressure: A systematic review and meta-analysis. Journal of the American Heart Association. 2013;2:e004473. Getting active to control high blood pressure. American Heart Association. http://www.heart.org/HEARTORG/ ...
An experimental microcomputer controlled system for synchronized pulsating anti-gravity suit.
Moore, T W; Foley, J; Reddy, B R; Kepics, F; Jaron, D
1987-07-01
An experimental system to deliver synchronized external pressure pulsations to the lower body is described in this technical note. The system is designed using a microcomputer with a real time interface and an electro-pneumatic subsystem capable of delivering pressure pulses to a modified anti-G suit at a fast rate. It is versatile, containing many options for synchronizing, phasing and sequencing of the pressure pulsations and controlling the pressure level in the suit bladders. Details of its software and hardware are described along with the results of initial testing in a Dynamic Flight Simulator on human volunteers.
Lei, Qiang; Lv, Yunhui; Li, Kai; Ma, Lei; Du, Guodong; Xiang, Yan; Li, Xuqing
2017-01-01
ABSTRACT Objective: To evaluate systematically the effects of continuous positive airway pressure (CPAP) on blood pressure in patients with resistant hypertension and obstructive sleep apnea (OSA). Methods: The Cochrane Library, PubMed, ScienceDirect, and the Web of Science were searched for studies investigating the effects of CPAP on blood pressure in patients with resistant hypertension and OSA. The selected studies underwent quality assessment and meta-analysis, as well as being tested for heterogeneity. Results: Six randomized controlled trials were included in the meta-analysis. The pooled estimates of the changes in mean systolic blood pressure and mean diastolic blood pressure (as assessed by 24-h ambulatory blood pressure monitoring) were −5.40 mmHg (95% CI: −9.17 to −1.64; p = 0.001; I2 = 74%) and −3.86 mmHg (95% CI: −6.41 to −1.30; p = 0.00001; I2 = 79%), respectively. Conclusions: CPAP therapy can significantly reduce blood pressure in patients with resistant hypertension and OSA. PMID:28767770
Increases in intramuscular pressure raise arterial blood pressure during dynamic exercise
NASA Technical Reports Server (NTRS)
Gallagher, K. M.; Fadel, P. J.; Smith, S. A.; Norton, K. H.; Querry, R. G.; Olivencia-Yurvati, A.; Raven, P. B.
2001-01-01
This investigation was designed to determine the role of intramuscular pressure-sensitive mechanoreceptors and chemically sensitive metaboreceptors in affecting the blood pressure response to dynamic exercise in humans. Sixteen subjects performed incremental (20 W/min) cycle exercise to fatigue under four conditions: control, exercise with thigh cuff occlusion of 90 Torr (Cuff occlusion), exercise with lower body positive pressure (LBPP) of 45 Torr, and a combination of thigh cuff occlusion and LBPP (combination). Indexes of central command (heart rate, oxygen uptake, ratings of perceived exertion, and electromyographic activity), cardiac output, stroke volume, and total peripheral resistance were not significantly different between the four conditions. Mechanical stimulation during LBPP and combination conditions resulted in significant elevations in intramuscular pressure and mean arterial pressure from control at rest and throughout the incremental exercise protocol (P < 0.05). Conversely, there existed no significant changes in mean arterial pressure when the metaboreflex was stimulated by cuff occlusion. These findings suggest that under normal conditions the mechanoreflex is tonically active and is the primary mediator of exercise pressor reflex-induced alterations in arterial blood pressure during submaximal dynamic exercise in humans.
1976-11-01
pressure switch . The system was tested for stability of operation and accuracy of pressure control, using a High Altitude Supersonic Target (HAST...stable and accurate to approximately the deadband of the pressure switch used, 2 psi. (Author)
The Baroreflex as a Long-Term Controller of Arterial Pressure
Iliescu, Radu
2015-01-01
Because of resetting, a role for baroreflexes in long-term control of arterial pressure has been commonly dismissed in the past. However, in recent years, this perspective has changed. Novel approaches for determining chronic neurohormonal and cardiovascular responses to natural variations in baroreceptor activity and to electrical stimulation of the carotid baroreflex indicate incomplete resetting and sustained responses that lead to long-term alterations in sympathetic activity and arterial pressure. PMID:25729060
Reverse-micelle-induced porous pressure-sensitive rubber for wearable human-machine interfaces.
Jung, Sungmook; Kim, Ji Hoon; Kim, Jaemin; Choi, Suji; Lee, Jongsu; Park, Inhyuk; Hyeon, Taeghwan; Kim, Dae-Hyeong
2014-07-23
A novel method to produce porous pressure-sensitive rubber is developed. For the controlled size distribution of embedded micropores, solution-based procedures using reverse micelles are adopted. The piezosensitivity of the pressure sensitive rubber is significantly increased by introducing micropores. Using this method, wearable human-machine interfaces are fabricated, which can be applied to the remote control of a robot. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Burkholder, Greer A; Tamhane, Ashutosh R; Safford, Monika M; Muntner, Paul M; Willig, Amanda L; Willig, James H; Raper, James L; Saag, Michael S; Mugavero, Michael J
2018-01-01
African Americans are disproportionately affected by both HIV and hypertension. Failure to modify risk factors for cardiovascular disease and chronic kidney disease such as hypertension among HIV-infected patients may attenuate the benefits conferred by combination antiretroviral therapy. In the general population, African Americans with hypertension are less likely to have controlled blood pressure than whites. However, racial differences in blood pressure control among HIV-infected patients are not well studied. We conducted a cross-sectional study evaluating racial differences in hypertension prevalence, treatment, and control among 1,664 patients attending the University of Alabama at Birmingham HIV Clinic in 2013. Multivariable analyses were performed to calculate prevalence ratios (PR) with 95% confidence intervals (CI) as the measure of association between race and hypertension prevalence and control while adjusting for other covariates. The mean age of patients was 47 years, 77% were male and 54% African-American. The prevalence of hypertension was higher among African Americans compared with whites (49% vs. 43%; p = 0.02). Among those with hypertension, 91% of African Americans and 93% of whites were treated (p = 0.43). Among those treated, 50% of African Americans versus 60% of whites had controlled blood pressure (systolic blood pressure <140 mmHg and diastolic blood pressure <90 mmHg) (p = 0.007). After multivariable adjustment for potential confounders, prevalence of hypertension was higher among African Americans compared to whites (PR 1.25; 95% CI 1.12-1.39) and prevalence of BP control was lower (PR 0.80; 95% CI 0.69-0.93). Despite comparable levels of hypertension treatment, African Americans in our HIV cohort were less likely to achieve blood pressure control. This may place them at increased risk for adverse outcomes that disproportionately impact HIV-infected patients, such as cardiovascular disease and chronic kidney disease, and thus attenuate the benefits conferred by combination antiretroviral therapy.
Zonnevijlle, Erik D H; Perez-Abadia, Gustavo; Stremel, Richard W; Maldonado, Claudio J; Kon, Moshe; Barker, John H
2003-11-01
Muscle tissue transplantation applied to regain or dynamically assist contractile functions is known as 'dynamic myoplasty'. Success rates of clinical applications are unpredictable, because of lack of endurance, ischemic lesions, abundant scar formation and inadequate performance of tasks due to lack of refined control. Electrical stimulation is used to control dynamic myoplasties and should be improved to reduce some of these drawbacks. Sequential segmental neuromuscular stimulation improves the endurance and closed-loop control offers refinement in rate of contraction of the muscle, while function-controlling stimulator algorithms present the possibility of performing more complex tasks. An acute feasibility study was performed in anaesthetised dogs combining these techniques. Electrically stimulated gracilis-based neo-sphincters were compared to native sphincters with regard to their ability to maintain continence. Measurements were made during fast bladder pressure changes, static high bladder pressure and slow filling of the bladder, mimicking among others posture changes, lifting heavy objects and diuresis. In general, neo-sphincter and native sphincter performance showed no significant difference during these measurements. However, during high bladder pressures reaching 40 cm H(2)O the neo-sphincters maintained positive pressure gradients, whereas most native sphincters relaxed. During slow filling of the bladder the neo-sphincters maintained a controlled positive pressure gradient for a prolonged time without any form of training. Furthermore, the accuracy of these maintained pressure gradients proved to be within the limits set up by the native sphincters. Refinements using more complicated self-learning function-controlling algorithms proved to be effective also and are briefly discussed. In conclusion, a combination of sequential stimulation, closed-loop control and function-controlling algorithms proved feasible in this dynamic graciloplasty-model. Neo-sphincters were created, which would probably provide an acceptable performance, when the stimulation system could be implanted and further tested. Sizing this technique down to implantable proportions seems to be justified and will enable exploration of the possible benefits.
Early cessation of pressure garment therapy results in scar contraction and thickening
DeBruler, Danielle M.; Zbinden, Jacob C.; Baumann, Molly E.; Blackstone, Britani N.; Malara, Megan M.; Bailey, J. Kevin
2018-01-01
Pressure garment therapy is often prescribed to improve scar properties following full-thickness burn injuries. Pressure garment therapy is generally recommended for long periods of time following injury (1–2 years), though it is plagued by extremely low patient compliance. The goal of this study was to examine the effects of early cessation of pressure garment therapy on scar properties. Full-thickness burn injuries were created along the dorsum of red Duroc pigs. The burn eschar was excised and wound sites autografted with split-thickness skin. Scars were treated with pressure garments within 1 week of injury and pressure was maintained for either 29 weeks (continuous pressure) or for 17 weeks followed by cessation of pressure for an additional 12 weeks (pressure released); scars receiving no treatment served as controls. Scars that underwent pressure garment therapy were significantly smoother and less contracted with decreased scar height compared to control scars at 17 weeks. These benefits were maintained in the continuous pressure group until week 29. In the pressure released group, grafts significantly contracted and became more raised, harder and rougher after the therapy was discontinued. Pressure cessation also resulted in large changes in collagen fiber orientation and increases in collagen fiber thickness. The results suggest that pressure garment therapy effectively improves scar properties following severe burn injury; however, early cessation of the therapy results in substantial loss of these improvements. PMID:29897933
Early cessation of pressure garment therapy results in scar contraction and thickening.
DeBruler, Danielle M; Zbinden, Jacob C; Baumann, Molly E; Blackstone, Britani N; Malara, Megan M; Bailey, J Kevin; Supp, Dorothy M; Powell, Heather M
2018-01-01
Pressure garment therapy is often prescribed to improve scar properties following full-thickness burn injuries. Pressure garment therapy is generally recommended for long periods of time following injury (1-2 years), though it is plagued by extremely low patient compliance. The goal of this study was to examine the effects of early cessation of pressure garment therapy on scar properties. Full-thickness burn injuries were created along the dorsum of red Duroc pigs. The burn eschar was excised and wound sites autografted with split-thickness skin. Scars were treated with pressure garments within 1 week of injury and pressure was maintained for either 29 weeks (continuous pressure) or for 17 weeks followed by cessation of pressure for an additional 12 weeks (pressure released); scars receiving no treatment served as controls. Scars that underwent pressure garment therapy were significantly smoother and less contracted with decreased scar height compared to control scars at 17 weeks. These benefits were maintained in the continuous pressure group until week 29. In the pressure released group, grafts significantly contracted and became more raised, harder and rougher after the therapy was discontinued. Pressure cessation also resulted in large changes in collagen fiber orientation and increases in collagen fiber thickness. The results suggest that pressure garment therapy effectively improves scar properties following severe burn injury; however, early cessation of the therapy results in substantial loss of these improvements.
Valsalva maneuver: Insights into baroreflex modulation of human sympathetic activity
NASA Technical Reports Server (NTRS)
Smith, Michael L.; Eckberg, Dwain L.; Fritsch, Janice M.; Beightol, Larry A.; Ellenbogen, Kenneth A.
1991-01-01
Valsalva's maneuver, voluntary forced expiration against a closed glottis, is a well-characterized research tool, used to assess the integrity of human autonomic cardiovascular control. Valsalva straining provokes a stereotyped succession of alternating positive and negative arterial pressure and heart rate changes mediated in part by arterial baroreceptors. Arterial pressure changes result primarily from fluctuating levels of venous return to the heart and changes of sympathetic nerve activity. Muscle sympathetic activity was measured directly in nine volunteers to explore quantitatively the relation between arterial pressure and human sympathetic outflow during pressure transients provoked by controlled graded Valsalva maneuvers. Our results underscore several properties of sympathetic regulation during Valsalva straining. First, muscle sympathetic nerve activity changes as a mirror image of changes in arterial pressure. Second, the magnitude of sympathetic augmentation during Valsalva straining predicts phase 4 arterial pressure elevations. Third, post-Valsalva sympathetic inhibition persists beyond the return of arterial and right atrial pressures to baseline levels which reflects an alteration of the normal relation between arterial pressure and muscle sympathetic activity. Therefore, Valsalva straining may have some utility for investigating changes of reflex control of sympathetic activity after space flight; however, measurement of beat-to-beat arterial pressure is essential for this use. The utility of this technique in microgravity can not be determined from these data. Further investigations are necessary to determine whether these relations are affected by the expansion of intrathoracic blood volume associated with microgravity.
Vozzi, Federico; Bianchi, Francesca; Ahluwalia, Arti; Domenici, Claudio
2014-01-01
Abundant experimental evidence demonstrates that endothelial cells are sensitive to flow; however, the effect of fluid pressure or pressure gradients that are used to drive viscous flow is not well understood. There are two principal physical forces exerted on the blood vessel wall by the passage of intra-luminal blood: pressure and shear. To analyze the effects of pressure and shear independently, these two stresses were applied to cultured cells in two different types of bioreactors: a pressure-controlled bioreactor and a laminar flow bioreactor, in which controlled levels of pressure or shear stress, respectively, can be generated. Using these bioreactor systems, endothelin-1 (ET-1) and nitric oxide (NO) release from human umbilical vein endothelial cells were measured under various shear stress and pressure conditions. Compared to the controls, a decrease of ET-1 production by the cells cultured in both bioreactors was observed, whereas NO synthesis was up-regulated in cells under shear stress, but was not modulated by hydrostatic pressure. These results show that the two hemodynamic forces acting on blood vessels affect endothelial cell function in different ways, and that both should be considered when planning in vitro experiments in the presence of flow. Understanding the individual and synergic effects of the two forces could provide important insights into physiological and pathological processes involved in vascular remodeling and adaptation. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Yuqian; Li, Zhihong; Li, Min; Yang, Yanlong; Wang, Bao; Gao, Li; Zhang, Xingye; Cheng, Hongyu; Fang, Wei; Zhao, Bo; Wang, Boliang; Gao, Guodong; Li, Lihong
2015-06-17
Elevated intracranial pressure is one of the most common problems in patients with diverse intracranial disorders, leading to increased morbidity and mortality. Effective management for increased intracranial pressure is based mainly on surgical and medical techniques with hyperosmolar therapy as one of the core medical treatments. The study aimed to explore the effects of continuous micro-pump infusions of 3% hypertonic saline combined with furosemide on intracranial pressure control. We analyzed data on 56 eligible participants with intracranial pressure >20 mmHg from March 2013 to July 2014. The target was to increase and maintain plasma sodium to a level between 145 and 155 mmol/L and osmolarity to a level of 310 to 320 mOsmol/kg. Plasma sodium levels significantly increased from 138±5 mmol/L at admission to 151±3 mmol/L at 24 h (P<0.01). Osmolarity increased from 282±11 mOsmol/kg at baseline to 311±8 mOsmol/kg at 24 h (P<0.01). Intracranial pressure significantly decreased from 32±7 mmHg to 15±6 mmHg at 24 h (P<0.01). There was a significant improvement in CPP (P<0.01). Moreover, central venous pressure, mean arterial pressure, and Glasgow Coma Scale slightly increased. However, these changes were not statistically significant. Continuous infusion of 3% hypertonic saline + furosemide is effective and safe for intracranial pressure control.
Perioperative factors associated with pressure ulcer development after major surgery.
Kim, Jeong Min; Lee, Hyunjeong; Ha, Taehoon; Na, Sungwon
2018-02-01
Postoperative pressure ulcers are important indicators of perioperative care quality, and are serious and expensive complications during critical care. This study aimed to identify perioperative risk factors for postoperative pressure ulcers. This retrospective case-control study evaluated 2,498 patients who underwent major surgery. Forty-three patients developed postoperative pressure ulcers and were matched to 86 control patients based on age, sex, surgery, and comorbidities. The pressure ulcer group had lower baseline hemoglobin and albumin levels, compared to the control group. The pressure ulcer group also had higher values for lactate levels, blood loss, and number of packed red blood cell ( p RBC) units. Univariate analysis revealed that pressure ulcer development was associated with preoperative hemoglobin levels, albumin levels, lactate levels, intraoperative blood loss, number of p RBC units, Acute Physiologic and Chronic Health Evaluation II score, Braden scale score, postoperative ventilator care, and patient restraint. In the multiple logistic regression analysis, only preoperative low albumin levels (odds ratio [OR]: 0.21, 95% CI: 0.05-0.82; P < 0.05) and high lactate levels (OR: 1.70, 95% CI: 1.07-2.71; P < 0.05) were independently associated with pressure ulcer development. A receiver operating characteristic curve was used to assess the predictive power of the logistic regression model, and the area under the curve was 0.88 (95% CI: 0.79-0.97; P < 0.001). The present study revealed that preoperative low albumin levels and high lactate levels were significantly associated with pressure ulcer development after surgery.