Prevalence of inter-arm blood pressure difference among clinical out-patients.
Sharma, Balkishan; Ramawat, Pramila
2016-04-01
An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (p<0.001) at different inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.
Prevalence of inter-arm blood pressure difference among clinical out-patients
Sharma, Balkishan; Ramawat, Pramila
2016-01-01
Objectives An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. Methodology 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. Results The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (p<0.001) at different inter arm blood pressure difference levels. Conclusion This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases. PMID:27103905
Effects of long-term low atmospheric pressure on gas exchange and growth of lettuce
NASA Astrophysics Data System (ADS)
Tang, Yongkang; Guo, Shuangsheng; Dong, Wenping; Qin, Lifeng; Ai, Weidang; Lin, Shan
2010-09-01
The objectives of this research were to determine photosynthesis, evapotranspiration and growth of lettuce at long-term low atmospheric pressure. Lettuce ( Lactuca sativa L . cv. Youmaicai) plants were grown at 40 kPa total pressure (8.4 kPa p) or 101 kPa total pressure (20.9 kPa p) from seed to harvest for 35 days. Germination rate of lettuce seeds decreased by 7.6% at low pressure, although this was not significant. There was no significant difference in crop photosynthetic rate between hypobaria and ambient pressure during the 35-day study. The crop evapotranspiration rate was significantly lower at low pressure than that at ambient pressure from 20 to 30 days after planting (DAP), but it had no significant difference before 20 DAP or after 30 DAP. The growth cycle of lettuce plants at low pressure was delayed. At low pressure, lettuce leaves were curly at the seedling stage and this disappeared gradually as the plants grew. Ambient lettuce plants were yellow and had an epinastic growth at harvest. The shoot height, leaf number, leaf length and shoot/root ratio were lower at low pressure than those at ambient pressure, while leaf area and root growth increased. Total biomass of lettuce plants grown at two pressures had no significant difference. Ethylene production at low pressure decreased significantly by 38.8% compared with ambient pressure. There was no significant difference in microelements, nutritional phytochemicals and nitrate concentrations at the two treatments. This research shows that lettuce can be grown at long-term low pressure (40 kPa) without significant adverse effects on seed germination, gas exchange and plant growth. Furthermore, ethylene release was reduced in hypobaria.
Brophy-Williams, Ned; Driller, Matthew William; Shing, Cecilia Mary; Fell, James William; Halson, Shona Leigh; Halson, Shona Louise
2015-01-01
The purpose of this investigation was to measure the interface pressure exerted by lower body sports compression garments, in order to assess the effect of garment type, size and posture in athletes. Twelve national-level boxers were fitted with sports compression garments (tights and leggings), each in three different sizes (undersized, recommended size and oversized). Interface pressure was assessed across six landmarks on the lower limb (ranging from medial malleolus to upper thigh) as athletes assumed sitting, standing and supine postures. Sports compression leggings exerted a significantly higher mean pressure than sports compression tights (P < 0.001). Oversized tights applied significantly less pressure than manufacturer-recommended size or undersized tights (P < 0.001), yet no significant differences were apparent between different-sized leggings. Standing posture resulted in significantly higher mean pressure application than a seated posture for both tights and leggings (P < 0.001 and P = 0.002, respectively). Pressure was different across landmarks, with analyses revealing a pressure profile that was neither strictly graduated nor progressive in nature. The pressure applied by sports compression garments is significantly affected by garment type, size and posture assumed by the wearer.
Zhao, Bowen; Zhang, Hongwei; Xu, Qiang; Ge, Quanhu; Li, Bolong; Peng, Xinyu; Wu, Xiangwei
2017-05-01
To investigate the effects of long time different negative pressures on osteogenic diffe-rentiation of rabbit bone mesenchymal stem cells (BMSCs). The rabbit BMSCs were isolated and cultured by density gradient centrifugation. Flow cytometry was used to analyze expression of surface markers. The third passage cells cultured under condition of osteogenic induction and under different negative pressure of 0 mm Hg (control group), 75 mm Hg (low negative pressure group), and 150 mm Hg (high negative pressure group) (1 mm Hg=0.133 kPa), and the negative pressure time was 30 min/h. Cell growth was observed under phase contrast microscopy, and the growth curve was drawn; alkaline phosphatase (ALP) activity was detected by ELISA after induced for 3, 7, and 14 days. The mRNA and protein expressions of collagen type I (COL-I) and osteocalcin (OC) in BMSCs were analyzed by real-time fluorescence quantitative PCR and Western blot. The cultured cells were identified as BMSCs by flow cytometry. The third passage BMSCs exhibited typical long shuttle and irregular shape. Cell proliferation was inhibited with the increase of negative pressure. After induced for 4 days, the cell number of high negative pressure group was significantly less than that in control group and low negative pressure group ( P <0.05), but there was no significant difference between the low negative pressure group and the control group ( P >0.05); at 5-7 days, the cell number showed significant difference between 3 groups ( P <0.05). The greater the negative pressure was, the greater the inhibition of cell proliferation was. There was no significant difference in ALP activity between groups at 3 days after induction ( P >0.05); the ALP activity showed significant difference ( P <0.05) between the high negative pressure group and the control group at 7 days after induction; and significant difference was found in the ALP activity between 3 groups at 14 days after induction ( P <0.05). The greater the negative pressure was, the higher the ALP activity was. Real-time fluorescence quantitative PCR and Western blot detection showed that the mRNA and protein expressions of COL-I and OC protein were significantly higher in low negative pressure group and high negative pressure group than control group ( P <0.05), and in the high negative pressure group than the low negative pressure group ( P <0.05). With the increase of the negative pressure, the osteogenic differentiation ability of BMSCs increases gradually, but the cell proliferation is inhibited.
Generational Differences in Resistance to Peer Pressure among Mexican-Origin Adolescents.
ERIC Educational Resources Information Center
Umana-Taylor, Adriana J.; Bamaca-Gomez, Mayra Y.
2003-01-01
Examined whether Mexican origin adolescents who varied by generational status would differ in their resistance to peer pressure. After controlling for gender, resistance to peer pressure varied significantly by generational status. Adolescents with no familial births in the United States were significantly more resistant to peer pressure than…
Huang, Xia; Cui, Jiwen
2015-07-01
To investigate the effect of different degrees of pressure of sustained inflation (SI) in patients with acute respiratory distress syndrome (ARDS) after lung recruitment as the result of different negative pressure for sputum aspiration. A prospective single-blind randomized controlled trial was conducted. The factorial analysis of variance was adopted. 150 patients with ARDS admitted to the emergency intensive care unit (ICU) of Chongqing Three Gorges Central Hospital from January 2012 to December 2014 were enrolled, and they were randomly divided into S1, S2, S3 group, with 50 patients in each group, suction pressure varying from 150, 175, to 200 mmHg (1 mmHg=0.133 kPa) was respectively used in each group. Then the patients of each group were randomly subdivided into five subgroups of P0, P1, P2, P3, P4, with 10 patients in each group, and 0, 30, 35, 40, and 45 cmH2O (1 cmH2O=0.098 kPa) were used for control pulmonary inflation pressure, respectively. The respiratory mechanics and the hemodynamic parameters were recorded, and they were compared before and after the sputum aspiration as well as lung recruitment with sustained inflation. The lung recruitment volume (mL: 87.56±28.47 vs. 109.38±34.63, t=3.573, P=0.001) and lung static compliance [Cst (mL/cmH2O): 27.69±13.25 vs. 35.87±17.47, t=2.814, P=0.004] after sputum aspiration in the 150 patients were significantly lower than those before the sputum aspiration, and peak airway pressure [PIP (cmH2O): 24.16±8.28 vs. 18.63±6.67, t=2.957, P=0.005], airway plateau pressure [Pplat (cmH2O): 21.28±9.14 vs. 17.47±7.26, t=2.089, P=0.032], and mean airway pressure [Pm (cmH2O): 13.26±4.65 vs. 10.41±3.54, t=3.271, P=0.001] were significantly higher than those before the treatment. There were no significant differences in the lung recruitment volume, Cst, PIP, Pplat and Pm between groups with different negative pressure for sputum aspiration (F value was 0.809, 0.986, 1.121, 0.910, 1.043, and P value was 0.452, 0.381, 0.335, 0.410, 0.361), but statistical significance was found among different groups of different lung recruitment pressures (F value was 3.581, 5.028, 3.064, 3.036, 4.050, and P value was 0.013, 0.002, 0.026, 0.027, 0.007). There was no interaction between the two factors. After pairwise comparison, under the same negative pressure for sputum aspiration, lung recruitment volume and Cst in different lung recruitment pressures subgroups (P1, P2, P3, P4) were significantly higher than those of P0 subgroup, and PIP, Pplat, and Pm were significantly lower than those of P0 subgroup. There was no significant difference among P1, P2, P3 and P4 groups. There were no significant differences in mean arterial pressure (MAP) and pulmonary arterial pressure (PAP) among different groups with negative pressures for sputum aspiration and different lung recruitment pressures (negative pressure for sputum aspiration: F=0.586, P=0.561, F=1.373, P=0.264; lung recruitment pressure: F=1.313, P=0.280, F=1.621, P=0.186), there was no interaction between the two factors (F=0.936, P=0.497, F=1.391, P=0.227). The difference of heart rate (HR) in different negative pressure for sputum aspiration groups was not significant (F=1.144, P=0.328), and there were significant differences in different lung recruitment pressure groups (F=3.297, P=0.019), there was no interaction between the two factors (F=1.277, P=0.280). After pairwise comparison, under the same negative pressure for sputum aspiration, HR in P3 and P4 subgroups was significantly higher than that in P0, P1, and P2 subgroups (all P<0.05). 30 cmH2O and 35 cmH2O were the suitable pressure for SI in ARDS patients, and they were not affected by different negative pressure for sputum aspiration.
Age-related differences in tongue-palate pressures for strength and swallowing tasks.
Fei, Tiffany; Polacco, Rebecca Cliffe; Hori, Sarah E; Molfenter, Sonja M; Peladeau-Pigeon, Melanie; Tsang, Clemence; Steele, Catriona M
2013-12-01
The tongue plays a key role in the generation of pressures for transporting liquids and foods through the mouth in swallowing. Recent studies suggest that there is an age-related decline in tongue strength in healthy adults. However, whether age-related changes occur in tongue pressures generated for the purpose of swallowing remains unclear. Prior literature in this regard does not clearly explore the influence of task on apparent age-related differences in tongue pressure amplitudes. Furthermore, differences attributable to variations across individuals in strength, independent of age, have not clearly been elucidated. In this study, our goal was to clarify whether older adults have reduced tongue-palate pressures during maximum isometric, saliva swallowing, and water swallowing tasks, while controlling for individual variations in strength. Data were collected from 40 healthy younger adults (under age 40) and 38 healthy mature adults (over age 60). As a group, the mature participants had significantly lower maximum isometric pressures (MIPs). Swallowing pressures differed significantly by task, with higher pressures seen in saliva swallows than in water swallows. Age-group differences were not seen in swallowing pressures. Consideration of MIP as a covariate in the analysis of swallowing pressures revealed significant correlations between strength and swallowing pressures in the older participant group. Age-group differences were evident only when strength was considered in the model, suggesting that apparent age-related differences are, in fact, explained by differences in strength, which tends to be lower in healthy older adults. Our results show no evidence of independent differences in swallowing pressures attributable to age.
Lower limb intracast pressures generated by different types of immobilisation casts.
Chaudhury, Salma; Hazlerigg, Alexandra; Vusirikala, Anuhya; Nguyen, Joseph; Matthews, Stuart
2017-02-18
To determine if complete, split casts and backslabs [plaster of Paris (POP) and fiberglass] generate different intracast pressures and pain. Increased swelling within casts was modeled by a closed water system attached to an expandable bag placed directly under different types of casts applied to a healthy lower limb. Complete fiberglass and POP casts, split casts and backslabs were applied. Twenty-five milliliter aliquots of saline were injected into the system and the generated intracast pressures were measured using a sphygmomanometer. The subject was blinded to the pressure scores to avoid bias. All casts were applied to the same right limb on the same subject to avoid the effects of variations in anatomy or physiology on intracast pressures. Pain levels were evaluated using the Visual Analogue Score after each sequential saline injection. Each type of cast was reapplied four times and the measurements were repeated on four separate occasions. Sample sizes were determined by a pre-study 90% power calculation to detect a 20% difference in intracast pressures between cast groups. A significant difference between the various types of casts was noted when the saline volume was greater than 100 mL ( P = 0.009). The greatest intracast pressure was generated by complete fiberglass casts, which were significantly higher than complete POP casts or backslabs ( P = 0.018 and P = 0.008 respectively) at intracast saline volumes of 100 mL and higher. Backslabs produced a significantly lower intracast pressure compared to complete POP only once the saline volume within casts exceeded 225 mL ( P = 0.009). Intracast pressures were significantly lower in split casts ( P = 0.003). Split POP and fiberglass casts produced the lowest intracast pressures, even compared to backslabs ( P = 0.009). Complete fiberglass casts generated the highest pain levels at manometer pressures of 75 mmHg and greater ( P = 0.001). Split fiberglass casts had significantly reduced pain levels ( P = 0.001). In contrast, a split complete POP cast did not produce significantly reduced pain levels at pressures between 25-150 mmHg. There was no difference in pain generated by complete POP and backslabs at manometer pressures of 200 mmHg and lower. Fibreglass casts generate significantly higher intracast pressures and pain than POP casts. Split casts cause lower intracast pressures regardless of material, than complete casts and backslabs.
Ideal resuscitation pressure for uncontrolled hemorrhagic shock in different ages and sexes of rats
2013-01-01
Introduction Our previous studies demonstrated that 50-60 mmHg mean arterial blood pressure was the ideal target hypotension for uncontrolled hemorrhagic shock during the active hemorrhage in sexually mature rats. The ideal target resuscitation pressure for immature and older rats has not been determined. Methods To elucidate this issue, using uncontrolled hemorrhagic-shock rats of different ages and sexes (6 weeks, 14 weeks and 1.5 years representing pre-adult, adult and older rats, respectively), the resuscitation effects of different target pressures (40, 50, 60, 70 and 80 mmHg) on uncontrolled hemorrhagic shock during active hemorrhage and the age and sex differences were observed. Results Different target resuscitation pressures had different resuscitation outcomes for the same age and sex of rats. The optimal target resuscitation pressures for 6-week-old, 14-week-old and 1.5-year-old rats were 40 to 50 mmHg, 50 to 60 mmHg and 70 mmHg respectively. Ideal target resuscitation pressures were significantly superior to other resuscitation pressures in improving the hemodynamics, blood perfusion, organ function and animal survival of uncontrolled hemorrhagic-shock rats (P < 0.01). For same target resuscitation pressures, the beneficial effect on hemorrhagic shock had a significant age difference (P < 0.01) but no sex difference (P > 0.05). Different resuscitation pressures had no effect on coagulation function. Conclusion Hemorrhagic-shock rats at different ages have different target resuscitation pressures during active hemorrhage. The ideal target resuscitation hypotension for 6-week-old, 14-week-old and 1.5-year-old rats was 40 to 50 mmHg, 50 to 60 mmHg and 70 mmHg, respectively. Their resuscitation effects have significant age difference but had no sex difference. PMID:24020401
Changes of contact pressure and area in patellofemoral joint after different meniscectomies.
Bai, Bo; Shun, Hui; Yin, Zhi Xun; Liao, Zhuang-Wen; Chen, Ni
2012-05-01
We investigated the contact pressure and area of the patellofemoral joint both before and after different meniscectomies to provide a biomechanical basis for selecting meniscectomy and its clinical application for meniscus injuries. Six fresh cadaveric knees were used in the study. Using Staubli robots and an ultra-low-min-type pressure-sensitive tablet, changes in contact area and stress in the patellofemoral joint were measured at various flexion angles following different parts and degrees of meniscectomy. The patellofemoral contact area enlarged with the increase of knee flexion angle. From the values obtained from contact areas and average contact pressure of the patellofemoral joint, we found no significant difference between partial meniscectomy and intact knees, but a significant difference was found between total meniscectomy and intact knees. The contact area after lateral meniscectomy was statistically less than that of intact knees. The mean patellofemoral contact pressure after lateral meniscectomy was larger than in intact knees at each angle of flexion. No significant difference in contact area was observed between intact knees and medial meniscectomy. The average patellofemoral contact pressure after medial meniscectomy was larger than in intact knees from 0° ~ 30° of knee flexion, and no significant differences were found between intact knees and medial meniscectomy while knee bending from 60° to 90°. Different meniscectomies result in high contact pressure or disordered distribution of contact pressure, which may be the cause of postoperative patellofemoral degenerative arthrosis.
Evaluation of Pressure Generated by Resistors From Different Positive Expiratory Pressure Devices.
Fagevik Olsén, Monika; Carlsson, Maria; Olsén, Erik; Westerdahl, Elisabeth
2015-10-01
Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. Resistors from 4 flow-regulated PEP devices (Pep/Rmt system, Wellspect HealthCare; Pipe P breathing exerciser, Koo Medical Equipment; Mini-PEP, Philips Respironics [including resistors by Rüsch]; and 15-mm endo-adapter, VBM Medizintechnik) were tested randomly by a blinded tester at constant flows of 10 and 18 L/min from an external gas system. All resistors were tested 3 times. Resistors with a similar diameter produced statistically significant different pressures at the same flow. The differences were smaller when the flow was 10 L/min compared with 18 L/min. The differences were also smaller when the diameter of the resistor was increased. The pressures produced by the 4 resistors of the same size were all significantly different when measuring 1.5- and 2.0-mm resistors at a flow of 10 L/min and 2.0-mm resistors at a flow of 18 L/min (P < .001). There were no significant differences between any of the resistors when testing sizes of 4.5 and 5.0 mm at either flow. The Mini-PEP and adapter resistors gave the highest pressures. Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures. Copyright © 2015 by Daedalus Enterprises.
Intra-abdominal pressure during swimming.
Moriyama, S; Ogita, F; Huang, Z; Kurobe, K; Nagira, A; Tanaka, T; Takahashi, H; Hirano, Y
2014-02-01
The present study aimed to determine the intra-abdominal pressure during front crawl swimming at different velocities in competitive swimmers and to clarify the relationships between stroke indices and changes in intra-abdominal pressure. The subjects were 7 highly trained competitive collegiate male swimmers. Intra-abdominal pressure was measured during front crawl swimming at 1.0, 1.2 and 1.4 m · s(-1) and during the Valsalva maneuver. Intra-abdominal pressure was taken as the difference between minimum and maximum values, and the mean of 6 stable front crawl stroke cycles was used. Stroke rate and stroke length were also measured as stroke indices. There were significant differences in stroke rate among all velocities (P < 0.05). However, there was no significant difference in stroke length by velocity. Significant within-subject correlations between intra-abdominal pressure and stroke rate or stroke length (P < 0.01) were observed, although there were no significant correlations between intra-abdominal pressure and stroke indices when controlling for swimming velocity. These findings do not appear to support the effectiveness of trunk training performed by competitive swimmers aimed at increasing intra-abdominal pressure. © Georg Thieme Verlag KG Stuttgart · New York.
Comparison of endotracheal tube cuff pressure values before and after training seminar.
Özcan, Ayça Tuba Dumanlı; Döğer, Cihan; But, Abdülkadir; Kutlu, Işık; Aksoy, Şemsi Mustafa
2018-06-01
It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O. In this present study, we intend to observe average cuff pressure values in our clinic and the change in these values after the training seminar. The cuff pressure values of 200 patients intubated following general anesthesia induction in the operating theatre were measured following intubation. One hundred patients whose values were measured before the training seminar held for all physician assistants, and 100 patients whose values were measured after the training seminar were regarded as Group 1 and Group 2, respectively. Cuff pressures of both groups were recorded, and the difference between them was shown. Moreover, cuff pressure values were explored according to the working period of the physician assistants. There was no significant difference between the groups in terms of age, gender and tube diameters. Statistically significant difference was found between cuff pressure values before and after the training (p < 0.001). Average pressure measure for Group I was 54 cm H 2 O, while average pressure in Group II declined to 33 cm H 2 O. It was observed that as the working period and experience of physician assistants increased, cuff pressure values decreased, however no statistically significant different was found (p < 0.375). We believe that clinical experience does not have significant effects on cuff pressure and that training seminars held at intervals would prevent high cuff pressure values and potential complications.
Pressure monitoring during lipofilling procedures.
Klein, S M; Prantl, L; Geis, S; Eisenmann-Klein, M; Dolderer, J; Felthaus, O; Loibl, M; Heine, N
2014-01-01
Grafting of autologous lipoaspirate for various clinical applications has become a common procedure in clinical practice. With an estimated mortality rate of 10-15 percent, fat embolism is among the most severe complications to be expected after lipofilling therapies. The aim of this study was to determine the level of interstitial pressure after the injection of defined volumes of lipoaspirate into the subcutaneous tissue of female breasts. It was hypothesized, that interstitial pressure levels exceed the physiologic capillary pressure during lipofilling procedures and hence increase the potential risk for fat embolism. Further it was investigated if external tissue expansion has the potential to significantly reduce interstitial tissue pressure. Interstitial pressure was monitored in 36 female patients, that underwent autologous fat injections into the breast. Measurements were conducted with a sensor needle connected to a pressure transducer (LogiCal Pressure Monitoring Kit, Smiths medical int. Ltd., UK). Patients were divided into 4 subcohorts differing in their pre-treatment regimen or local tissue conditions. Pre-treatment consisted of tissue expansion, achieved with the Brava™ (Brava LLC Miami, Fla., USA) vacuum-chamber. The increase in interstitial pressure after injection volumes of 100 ml (p = 0.006), 200 ml (p = 0.000) and between 100 ml and 200 ml (p = 0.004) respectively, were significant in non-mastectomized patients without pre-treatment. Patients pre-treated with Brava™ did not show such statistically significant differences in interstitial pressures before and after the injection of 100 ml and 200 ml of lipoaspirate (p = 0.178). The difference in interstitial pressure in mastectomized patients between 0 ml and 100 ml (p = 0.003), as well as 0 ml and 200 ml (p = 0.028) was significant. The difference in pressures between pre-treated patients and patients without pre-treatment did not differ significantly in the mastectomized patient cohort. During lipofilling procedures interstitial pressures are reached that exceed pressure limits defined as hazardous for fat embolism. To date it is unknown what pressure levels need to be considered critical for complications in soft tissue interventions. Further the results indicate higher interstitial pressures for patients that had undergone mastectomy, whereas pre-treatment with external tissue expansion seemed to diminish pressure values.
Effect of high hydrostatic pressure on overall quality parameters of watermelon juice.
Liu, Y; Zhao, X Y; Zou, L; Hu, X S
2013-06-01
High hydrostatic pressure as a kind of non-thermal processing might maintain the quality of thermo-sensitive watermelon juice. So, the effect of high hydrostatic pressure treatment on enzymes and quality of watermelon juice was investigated. After high hydrostatic pressure treatment, the activities of polyphenol oxidase, peroxidase, and pectin methylesterase of juice decreased significantly with the pressure (P < 0.05). Inactivation of polyphenol oxidase and peroxidase could be fitted by two-fraction model and that of pectin methylesterase could be described by first-order reaction model. Titratable acidity, pH, and total soluble solid of juice did not change significantly (P > 0.05). No significant difference was observed in lycopene and total phenolics after high hydrostatic pressure treatment when compared to the control (P > 0.05). Cloudiness and viscosity increased with pressure (P < 0.05) but did not change significantly with treatment time (P > 0.05). a*- and b*-value both unchanged after high hydrostatic pressure treatment (P > 0.05) while L*-value increased but the values had no significant difference among treated juices. Browning degree after high hydrostatic pressure treatment decreased with increase in pressure and treatment time (P < 0.05). Through the comparison of total color difference values, high hydrostatic pressure had little effect on color of juice. The results of this study demonstrated the efficacy of high hydrostatic pressure in inactivating enzymes and maintaining the quality of watermelon juice.
Allergic rhinitis and arterial blood pressure: a population-based study.
Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S
2018-05-01
To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.
Wang, Qi; Yu, Wei-Chang; Jiang, Hong-Zhi; Chen, Sheng-Li; Zhang, Ming-Min; Kong, E-Sheng; Huang, Guang-Ying
2010-12-01
To explore the relation between gap junction and meridian phenomenon. The oxygen partial pressure in acupoints [see text for formula] and in their corresponding non-acupoints of the Bladder Meridian was observed with the needle-type tissue oxygen tension sensor in the gap junction blocking goats by 1-Heptanol injection and the Connexin 43 (Cx43) gene knockout mice. (1) The oxygen partial pressure in acupoints of Bladder Meridian on goats was higher than that in non-acupoints after 1-Heptanol injection with significant differences between them (both P < 0.01). (2) The oxygen partial pressure in acupoints of Bladder Meridian on goats increased significantly after injecting 1-Heptanol as compare with that either injecting normal saline or injecting nothing with significant differences between them (all P < 0.01). (3) The oxygen partial pressure in acupoints of the Bladder Meridian was significantly higher than that in the non-acupoint controls in Cx43 wild type (WT) mice (all P < 0.01). In Cx43 heterozygote (HT) mice, the oxygen partial pressure between acupoints and non-acupoint controls showed no significant differences (all P > 0.05). (4) In acupoints, the oxygen partial pressure in Cx43 WT mice was significantly higher than that in Cx43 HT mice (all P < 0.05), while in the corresponding non-acupoints, this difference had no statistically significant (all P > 0.05). Gap junction maybe the essential factor in signal transduction of acupuncture.
Alemi, Hamid; Khaloo, Pegah; Mansournia, Mohammad Ali; Rabizadeh, Soghra; Salehi, Salome Sadat; Mirmiranpour, Hossein; Meftah, Neda; Esteghamati, Alireza; Nakhjavani, Manouchehr
2018-02-01
Type 2 diabetes is associated with higher pulse pressure. In this study, we assessed and compared effects of classic diabetes treatments on pulse pressure (PP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) in patients with type 2 diabetes.In a retrospective cohort study, 718 non-hypertensive patients with type 2 diabetes were selected and divided into 4 groups including metformin, insulin, glibenclamide+metformin, and metformin+insulin. They were followed for 4 consecutive visits lasting about 45.5 months. Effects of drug regimens on pulse and blood pressure over time were assessed separately and compared in regression models with generalized estimating equation method and were adjusted for age, duration of diabetes, sex, smoking, and body mass index (BMI).Studied groups had no significant change in PP, SBP, and DBP over time. No significant difference in PP and DBP among studied groups was observed (PP:P = 0.090; DBP:P = 0.063). Pairwise comparisons of PP, SBP, and DBP showed no statistically significant contrast between any 2 studied groups. Interactions of time and treatment were not different among groups.Our results demonstrate patients using metformin got higher PP and SBP over time. Averagely, pulse and blood pressure among groups were not different. Trends of variation in pulse and blood pressure were not different among studied diabetes treatments.
Chopra, Sakshi; Gupta, Narendra Kumar; Tandan, Amrit; Dwivedi, Ravi; Gupta, Swati; Agarwal, Garima
2016-01-01
Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. A significant difference in the pressure produced using different impression materials was found (P < 0.001). Light body vinyl polysiloxane produced significantly lesser pressure than zinc oxide eugenol impression materials. The presence of relief did affect the magnitude of pressure at various locations. All impression materials produced pressure during maxillary edentulous impression making. Tray modification is an important factor in changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.
Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan
2013-01-01
This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels.
Angioli, Roberto; Terranova, Corrado; Plotti, Francesco; Cafà, Ester Valentina; Gennari, Paolo; Ricciardi, Roberto; Aloisi, Alessia; Miranda, Andrea; Montera, Roberto; De Cicco Nardone, Carlo
2015-04-01
Studies on the influence of CO₂ pneumoperitoneum on the abdominal cavity during robotic procedures are lacking. This is the first study to evaluate surgical field modifications related to CO₂ pressure, during laparoscopic and robotic surgery. Consecutive patients scheduled for laparoscopic or robotic hysterectomy were enrolled in the study. To evaluate the level of operative field visualization, a dedicated form has been designed based on the evaluation of four different areas: Douglas space, vesico-uterine fold and, bilaterally, the broad ligament. During the initial inspection, an assistant randomly set the CO₂ pressure at 15, 10 and 5 mmHg, and the surgeon, not aware of the CO₂ values, was asked to give an evaluation of the four areas for each set pressure. In laparoscopic group, CO₂ pressure significantly influenced the surgical field visualization in all four areas analyzed. The surgeon had a good visualization only at 15 mmHg CO₂ pressure; visualization decreased with a statistically significant difference from 15 to 5, 15-10 and 10-5 mmHg. In robotic group, influence of CO₂ pressure on surgical areas visualization was not straightforward; operative field visualization remained stable at any pressure value with no significant difference. Pneumoperitoneum pressure significantly affects the visualization of the abdomino-pelvic cavity in laparoscopic procedures. Otherwise, CO₂ pressure does not affect the visualization of surgical field during robotic surgery. These findings are particularly significant especially at low CO₂ pressure with potential implications on peritoneal environment and the subsequent post-operative patient recovery.
Harris, R D; Phillips, R L; Williams, P M; Kuzma, J W; Fraser, G E
1981-12-01
Distribution of systolic and diastolic blood pressures (measured with an automated blood pressure recorder) of two large groups of children-3,159 from Seventh-Day Adventist (SDA) schools and 4,681 from non-SDA schools-are reported. They boys and girls were from four different ethnic groups and attended grades one through 10 in 29 Southern California schools. The analysis of the data failed to show significant differences in mean blood pressure levels between the two groups of children at all ages, despite marked differences in life-style between the two groups, and despite the fact that adults from the two population groups have marked differences in mortality from diseases associated with elevated blood pressure. A comparison between boys and girls showed significantly higher trends in mean systolic blood pressure for boys after age 12. Inter-ethnic comparisons of blood pressure revealed that Black children of both sexes had slightly higher mean blood pressure levels at all ages.
Harris, R D; Phillips, R L; Williams, P M; Kuzma, J W; Fraser, G E
1981-01-01
Distribution of systolic and diastolic blood pressures (measured with an automated blood pressure recorder) of two large groups of children-3,159 from Seventh-Day Adventist (SDA) schools and 4,681 from non-SDA schools-are reported. They boys and girls were from four different ethnic groups and attended grades one through 10 in 29 Southern California schools. The analysis of the data failed to show significant differences in mean blood pressure levels between the two groups of children at all ages, despite marked differences in life-style between the two groups, and despite the fact that adults from the two population groups have marked differences in mortality from diseases associated with elevated blood pressure. A comparison between boys and girls showed significantly higher trends in mean systolic blood pressure for boys after age 12. Inter-ethnic comparisons of blood pressure revealed that Black children of both sexes had slightly higher mean blood pressure levels at all ages. PMID:7315999
Periyasamy, R; Mishra, A; Anand, Sneh; Ammini, A C
2011-09-01
Women and men are anatomically and physiologically different in a number of ways. They differ in both shape and size. These differences could potentially mean foot pressure distribution variation in men and women. The purpose of this study was to analyze standing foot pressure image to obtain the foot pressure distribution parameter - power ratio variation between men and women using image processing in frequency domain. We examined 28 healthy adult subjects (14 men and 14 women) aged between 20 and 45 years was recruited for our study. Foot pressure distribution patterns while standing are obtained by using a PedoPowerGraph plantar pressure measurement system for foot image formation, a digital camera for image capturing, a TV tuner PC-add on card, a WinDvr software for still capture and Matlab software with dedicated image processing algorithms have been developed. Various PedoPowerGraphic parameters such as percentage medial impulse (PMI), fore foot to hind foot pressure distribution ratio (F/H), big toe to fore foot pressure distribution ratio (B/F) and power ratio (PR) were evaluated. In men, contact area was significantly larger in all regions of the foot compared with women. There were significant differences in plantar pressure distribution but there was no significant difference in F/H and B/F ratio. Mean PR value was significantly greater in men than women under the hind foot and fore foot. PMI value was greater in women than men. As compared to men, women have maximum PR variations in the mid foot. Hence there is significant difference at level p<0.05 in medial mid foot and mid foot PR of women as compared to men. There was variation in plantar pressure distribution because the contact area of the men foot was larger than that of women foot. Hence knowledge of pressure distributions variation of both feet can provide suitable guidelines to biomedical engineers and doctor for designing orthotic devices for reliving the area of excessively high pressure. Copyright © 2011 Elsevier Ltd. All rights reserved.
Lung, Chi-Wen; Yang, Tim D; Crane, Barbara A; Elliott, Jeannette; Dicianno, Brad E; Jan, Yih-Kuen
2014-01-01
The purpose of this study was to determine the effect of the sensel window's location and size when calculating the peak pressure index (PPI) of pressure mapping with varying degrees of wheelchair tilt-in-space (tilt) and recline in people with spinal cord injury (SCI). Thirteen power wheelchair users were recruited into this study. Six combinations of wheelchair tilt (15°, 25°, and 35°) and recline (10° and 30°) were used by the participants in random order. Displacements of peak pressure and center of pressure were extracted from the left side of the mapping system. Normalized PPI was computed for three sensel window dimensions (3 sensels × 3 sensels, 5 × 5, and 7 × 7). At least 3.33 cm of Euclidean displacement of peak pressures was observed in the tilt and recline. For every tilt angle, peak pressure displacement was not significantly different between 10° and 30° recline, while center of pressure displacement was significantly different (P < .05). For each recline angle, peak pressure displacement was not significantly different between pairs of 15°, 25°, and 35° tilt, while center of pressure displacement was significantly different between 15° versus 35° and 25° versus 35°. Our study showed that peak pressure displacement occurs in response to wheelchair tilt and recline, suggesting that the selected sensel window locations used to calculate PPI should be adjusted during changes in wheelchair configuration.
Kim, Sung-Jae; Kim, Sung-Hwan; Moon, Hyun-Soo; Chun, Yong-Min
2016-01-01
To quantify and compare the footprint contact area and interface pressure on the greater tuberosity between knotless and knot-tying transosseous-equivalent (TOE) repair using pressure-sensitive film. We used 11 pairs of fresh-frozen cadaveric shoulders (22 specimens), in which rotator cuff tears were created before repair. Each pair was randomized to either conventional medial knot-tying TOE repair (group A) or medial knotless TOE repair using the modified Mason-Allen technique (group B). Pressure-sensitive film was used to quantify the pressurized contact area and interface pressure between the greater tuberosity and supraspinatus tendon. The mean pressurized contact area was 33.2 ± 2.5 mm(2) for group A and 28.4 ± 2.4 mm(2) for group B. There was a significant difference between groups (P = .005). Although the overall contact configuration of both groups was similar and showed an M shape, group A showed a greater pressurized configuration around the medial row. The mean interface pressure was 0.20 ± 0.02 MPa for group A and 0.17 ± 0.02 MPa for group B. There was a significant difference between groups (P = .001). Contrary to our hypothesis, in this time-zero study, medial knotless TOE repair using a modified Mason-Allen suture produced a significantly inferior footprint contact area and interface pressure compared with conventional medial knot-tying TOE repair. Even though we found a statistically significant difference between the 2 repair methods, it is still unknown if this statistical difference seen in our study has any clinical and radiologic significance. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Takayanagi, Naoto; Sudo, Motoki; Fujii, Masahiko; Sakai, Hirokazu; Morimoto, Keiko; Tomisaki, Masumi; Niki, Yoshifumi; Tokimitsu, Ichiro
2018-03-01
[Purpose] This study evaluated gait parameters and foot pressure in two regions of the feet among older females with different personal care support needs to analyze factors that contribute to higher support requirements. [Subjects and Methods] Thirty-two older females were divided into support-need and care-need level groups. Gait parameters (speed, cadence, step length, step width, gait angle, toe angle, double support phase, swing phase, and stance phase) and foot pressure during a 5-m walk were measured and analyzed in the two groups. [Results] The percentage of the double support phase on both feet and the right stance phase were significantly higher in the care-need level group, while that of the right swing phase was significantly lower than that of the support-need level group. Additionally, the phase showing peak pressure on the left rear foot was significantly delayed and the left forefoot pressure in the terminal stance was significantly lower in the care-need level group than in the support-need level group. [Conclusion] These findings show that the temporal duration parameters and foot pressure on a particular side were significantly different between the two groups and suggest that these differences were associated with a higher care level.
Student measurement of blood pressure using a simulator arm compared with a live subject's arm.
Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L
2010-06-15
To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.
Van den Kerckhove, Eric; Fieuws, Steffen; Massagé, Patrick; Hierner, Robert; Boeckx, Willy; Deleuze, Jean-Paul; Laperre, Jan; Anthonissen, Mieke
2007-08-01
This study investigated the reproducibility of repeated measurements with the Kikuhime pressure sensor under two different types of pressure garments used in the treatment and prevention of scars after burns. Also efficiency of garments was assessed in clinical circumstances by assessing pressure loss and residual pressure after 1 month. Intra- and inter-observer reproducibility and repeated measurements with 1-month time lapse were examined on 55 sites in 26 subjects by means of intra-class correlation coefficients and standard error of measurements. Results showed good to excellent ICC and low SEMs in the two conditions. There was a significant difference in pressure after 1 month between elastic tricot and weft knit garments, although evolution of pressure loss after 1 month was similar. Concerning different locations, there was a significant difference in pressure loss after 1 month between gloves and sleeves with the largest pressure loss for sleeves. Considering these results we concluded that the Kikuhime pressure sensor provides valid and reliable information and can be used in comparative clinical trials to evaluate pressure garments used in burn scar treatment. Secondly, elastic tricot garments in our study tended to have higher clinical pressures but both types of garments had similar pressure loss over time.
The Influence of Backrest Inclination on Buttock Pressure
Park, Un Jin
2011-01-01
Objective To assess the effects of backrest inclination of a wheelchair on buttock pressures in spinal cord injured (SCI) patients and normal subjects. Method The participants were 22 healthy subjects and 22 SCI patients. Buttock pressures of the participants were measured by a Tekscan® pressure sensing mat and software while they were sitting in a reclining wheelchair. Buttock pressures were recorded for 90°, 100°, 110°, 120° and 130° seat-to-back angles at the ischial tuberosity (IT) and sacrococcygeal (SC) areas. Recordings were made at each angle over four seconds at a sampling rate of 10 Hz. Results The side-to-side buttock pressure differences in the IT area for the SCI patients was significantly greater than for the normal subjects. There was no significant difference between the SCI patients and the normal subjects in the buttock pressure change pattern of the IT area. Significant increases in pressure on the SC area were found as backrest inclination angle was changed to 90°, 100° and 110° in the normal subjects, but no significant differences were found in the SCI patients. Conclusion Most of the SCI patients have freeform posture in wheelchairs, and this leads to an uneven distribution of buttock pressure. In the SCI patients, the peak pressure in the IT area reduced as the backrest angle was increased, but peak pressure at the SC area remained relatively unchanged. To reduce buttock pressure and prevent pressure ulcers and enhance ulcer healing, it can be helpful for tetraplegic patients, to have wheelchair seat-to-back angles above 120°. PMID:22506220
Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan
2013-01-01
Background and Objectives. This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. Materials and Methods. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. Results. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). Conclusion. No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels. PMID:23781252
Dan, Haruka; Azuma, Teruaki; Hayakawa, Fumiyo; Kohyama, Kaoru
2005-05-01
This study was designed to examine human subjects' ability to discriminate between spatially different bite pressures. We measured actual bite pressure distribution when subjects simultaneously bit two silicone rubber samples with different hardnesses using their right and left incisors. They were instructed to compare the hardness of these two rubber samples and indicate which was harder (right or left). The correct-answer rates were statistically significant at P < 0.05 for all pairs of different right and left silicone rubber hardnesses. Simultaneous bite measurements using a multiple-point sheet sensor demonstrated that the bite force, active pressure and maximum pressure point were greater for the harder silicone rubber sample. The difference between the left and right was statistically significant (P < 0.05) for all pairs with different silicone rubber hardnesses. We demonstrated for the first time that subjects could perceive and discriminate between spatially different bite pressures during a single bite with incisors. Differences of the bite force, pressure and the maximum pressure point between the right and left silicone samples should be sensory cues for spatial hardness discrimination.
Effect of varying the pressurisation rate during noninvasive pressure support ventilation.
Prinianakis, G; Delmastro, M; Carlucci, A; Ceriana, P; Nava, S
2004-02-01
The aim of the study was to assess the effects of varying the pressurisation rate during noninvasive pressure support ventilation on patients' breathing pattern, inspiratory effort, arterial blood gases, tolerance to ventilation and amount of air leakage. A total of 15 chronic obstructive pulmonary disease patients recovering from an acute episode of hypercapnic acute respiratory failure were studied during four randomised trials with different levels of pressurisation rate. No significant changes were observed in breathing pattern and arterial blood gases between the different runs. The pressure time product of the diaphragm, an estimate of its metabolic consumption, was significantly lower with all pressurisation rates than with spontaneous breathing, but was significantly lowest with the fastest rate. However, air leak, assessed by the ratio between expired and inspired tidal volumes, increased and the patients' tolerance of ventilation, measured using a standardised scale, was significantly poorer with the fastest pressurisation rate. In chronic obstructive pulmonary disease patients recovering from an episode of acute hypercapnic respiratory failure and ventilated with noninvasive pressure support ventilation, different pressurisation rates resulted in different reductions in the pressure time product of the diaphragm; this reduction was greater with the fastest rate, but was accompanied by significant air leaks and poor tolerance.
Foot pressures during gait: a comparison of techniques for reducing pressure points.
Lawless, M W; Reveal, G T; Laughlin, R T
2001-07-01
Various methods have been used to redistribute plantar surface foot pressure in patients with foot ulcers. This study was conducted to determine the effectiveness of four modalities (fracture walker, fracture walker with insert, and open and closed toe total contact casts) in reducing plantar foot pressure. Ten healthy, normal volunteer subjects had an F-scan sensor (ultra thin shoe insert pressure monitor) placed under the right foot. They then ambulated on a flat surface, maintaining their normal gait. Dynamic plantar pressures were averaged over 10 steps at four different sites (plantar surface of great toe, first metatarsal head, base of fifth metatarsal, and plantar heel). All subjects repeated this sequence under five different testing conditions (barefoot, with a fracture walker, fracture walker with arch support insert, open and closed toe total contact cast). Each subject's barefoot pressures were then compared with the pressures during the different modalities. All four treatment modalities significantly reduced (p < 0.05) plantar pressure at the first metatarsal head (no method was superior). The fracture walker, fracture walker with insert, and open toe total contact cast significantly reduced pressure at the heel. Pressures at the base of the fifth metatarsal and great toe were not significantly reduced with any treatment form. The fracture walker, with and without arch support, and total contact cast can effectively reduce plantar pressure at the heel and first metatarsal head.
Owen, Christopher G; Whincup, Peter H; Gilg, Julie A; Cook, Derek G
2003-11-22
To determine whether breast feeding in infancy compared with bottle feeding formula milk is associated with lower mean blood pressure at different ages. Systematic review. Embase, Medline, and Web of Science databases. Studies showing the effects of feeding in infancy on blood pressure at different ages. Pooled mean differences in blood pressure between breast fed infants and those bottle fed formula milk, based on random effects models. The pooled mean difference in systolic blood pressure was -1.10 mm Hg (95% confidence interval -1.79 to -0.42 mm Hg) but with significant heterogeneity between estimates (P < 0.001). The difference was largest in studies of < 300 participants (-2.05 mm Hg, -3.30 to -0.80 mm Hg), intermediate in studies of 300-1000 participants (1.13 mm Hg, -2.53 to 0.27 mm Hg), and smallest in studies of > 1000 participants (-0.16 mm Hg, -0.60 to 0.28 mm Hg). An Egger test but not Begg test was statistically significant for publication bias. The difference was unaltered by adjustment for current size and was independent of age at measurement of blood pressure and year of birth. Diastolic blood pressure was not significantly related to type of feeding in infancy. Selective publication of small studies with positive findings may have exaggerated claims that breast feeding in infancy reduces systolic blood pressure in later life. The results of larger studies suggest that feeding in infancy has at most a modest effect on blood pressure, which is of limited clinical or public health importance.
Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan
2014-12-01
This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval -3.5 to -2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.
Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan
2014-01-01
Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval −3.5 to −2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675
Inter-arm blood pressure differences in pregnant women.
Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H
2008-08-01
To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.
Hasan, Y; Go, J; Hashmi, S M; Valestin, J; Schey, R
2015-04-01
The standard protocol for esophageal manometry involves placing the patient in the supine position with head turned to left (supine head left [SHL]) while evaluating liquid bolus swallows. Routinely, semisolid or solid boluses are not evaluated. Currently, the daily American diet includes up to 40% solid or semisolid texture. Thus far, the data on the effect of different bolus on high-resolution esophageal pressure topography (HREPT) parameters are scarce. This study aims to evaluate the effect of every day bolus consistencies in different body positions on HREPT variables. HREPT was performed on healthy volunteers with a modified protocol including liquid swallows in the SHL position followed by applesauce (semisolid), cracker (solid), and marshmallow (soft solid) in three different positions (SHL, sitting, and standing). A total of 38 healthy adult subjects (22 males and 16 females, median age = 27, and mean body mass index = 25) were evaluated. The resting upper esophageal sphincter pressure was significantly different while subjects swallowed crackers, applesauce, and marshmallows in most positions compared with liquid SHL (P < 0.05). The lower esophageal sphincter, contractile front velocity, and distal contractile integral pressures did not differ in all different consistencies compared with SHL. The integrated relaxation period was significantly higher with solid bolus compared with liquid bolus only in SHL position. The intrabolus pressure was significantly different with solid and soft solid boluses in all postures compared to liquid SHL. The American diet consistency affects upper esophageal sphincter pressure and partially integrated relaxation period and intrabolus pressure in various positions. Semisolid bolus swallows do not cause substantial pressure changes and are safe for evaluation and maintaining adequate caloric intake in patients with dysphagia who cannot tolerate solids. © 2014 International Society for Diseases of the Esophagus.
Cui, W; Wang, H; Wu, T; Ouyang, Q; Hu, S; Zhu, Y
2017-03-01
Passengers in aircraft cabins are exposed to low-pressure environments. One of the missing links in the research on thermal comfort under cabin conditions is the influence of low air pressure on the metabolic rate. In this research, we simulated the cabin pressure regime in a chamber in which the pressure level could be controlled. Three pressure levels (101/85/70 kPa) were tested to investigate how metabolic rate changed at different pressure levels. The results show that as pressure decreased, the respiratory flow rate (RFR) at standard condition (STPD: 0°C, 101 kPa) significantly decreased. Yet the oxygen (O 2 ) consumption and carbon dioxide (CO 2 ) production significantly increased, as reflected in the larger concentration difference between inhaled and exhaled air. A significant increase in the respiratory quotient (RQ) was also observed. For metabolic rate, no significant increase (P > 0.05) was detected when pressure decreased from 101 kPa to 85 kPa; however, the increase associated with a pressure decrease from 85 kPa to 70kPa was significant (P < 0.05). Empirical equations describing the above parameters are provided, which can be helpful for thermal comfort assessment in short-haul flights. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mittmann, Philipp; Ernst, A; Mittmann, M; Todt, I
2016-11-01
To preserve residual hearing in cochlear implant candidates, the atraumatic insertion of the cochlea electrode has become a focus of cochlea implant research. In a previous study, intracochlear pressure changes during the opening of the round window membrane were investigated. In the current study, intracochlear pressure changes during opening of the round window membrane under dry and transfluid conditions were investigated. Round window openings were performed in an artificial cochlear model. Intracochlear pressure changes were measured using a micro-optical pressure sensor, which was placed in the apex. Openings of the round window membrane were performed under dry and wet conditions using a cannula and a diode laser. Statistically significant differences in the intracochlear pressure changes were seen between the different methods used for opening of the round window membrane. Lower pressure changes were seen by opening the round window membrane with the diode laser than with the cannula. A significant difference was seen between the dry and wet conditions. The atraumatic approach to the cochlea is assumed to be essential for the preservation of residual hearing. Opening of the round window under wet conditions produce a significant advantage on intracochlear pressure changes in comparison to dry conditions by limiting negative outward pressure.
Acute baroreflex resetting: differential control of pressure and nerve activity.
Drummond, H A; Seagard, J L
1996-03-01
This study evaluated acute resetting of carotid baroreflex control of arterial blood pressure and renal or thoracic sympathetic nerve activity in thiopental-anesthetized mongrel dogs with the use of a vascularly isolated carotid sinus preparation, the experimental model used previously to characterize acute resetting in carotid baroreceptor afferent fibers. Carotid baroreceptors were conditioned with a pulsatile pressure for 20 minutes at three pressure ranges: low (50 to 75 mm Hg), mid (100 to 125), or high (150 to 175). Blood pressure and nerve activity were recorded in response to slow ramp increases in sinus pressure; nonlinear regression and best-fit analyses were used for determination of curve fit parameters of the blood pressure and nerve activity versus sinus pressure response curves. Carotid sinus pressure thresholds for blood pressure and renal nerve activity responses at all conditioning pressures were significantly different; however, only the pressure threshold for thoracic nerve activity at the low conditioning pressure was significantly different from the responses at other conditioning pressures. Average renal activity resetting (0.506 +/- 0.072) was significantly greater than blood pressure resetting (0.335 +/- 0.046) in the same dogs, and thoracic activity (0.200 +/- 0.057) was not different from blood pressure resetting (0.194 +/- 0.031) in the same dogs. In a previous investigation, our laboratory had demonstrated that type 1 carotid baroreceptors acutely reset at a value of about 0.15. These results indicate that (1) renal and thoracic nerve activities and blood pressure acutely reset to a greater degree than type 1 carotid baroreceptors and that (2) renal activity acutely resets to a greater degree than blood pressure and thoracic nerve activity.
Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types.
Sembiring, Krisnarta; Ramayani, Oke Rina; Lubis, Munar
2018-02-15
Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. To determine the difference in mean blood pressure among adolescents based on dyssomnia types. Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep Disturbance Scale for Children (SDSC) questionnaire. Stature and blood pressure data were collected along with demographic data and sleep disorder questionnaire. Analyses were done with Kruskal-Wallis test and logistic regression. P - value < 0.05 was considered significant. Seventy-six samples were obtained with mean age 13.9 (SD 1.14) years - old. Dyssomnia proportion and hypertension were 72/76 and 20/76 respectively. Mean systolic (SBP) and diastolic blood pressure (DBP) was 111.1 (SD 16.46) mmHg and 70.3 (SD 11.98) mmHg respectively. Mean SDSC score was 49.7 (SD 8.96), and the most frequent dyssomnia type was disorders of initiating and maintaining sleep. Age and sex were not the risk factors of hypertension in dyssomnia. There was a significant difference in mean SBP (P = 0.006) and DBP (P = 0.022) based on dyssomnia types. Combination dyssomnia type had the highest mean blood pressure among dyssomnia types. There is a significant difference in mean blood pressure among adolescents based on dyssomnia types.
Cycling on rollers: influence of tyre pressure and cross section on power requirements.
Reiser, Raoul; Watt, Jon; Peterson, Michael
2003-07-01
The resistance against a cyclist while riding on rollers is due mainly to rolling resistance produced by the deformation of the tyre as it rolls against small diameter drums. Resistance is then combined with wheel speed to set power output. The effect of tyre pressure and cross-section on power was investigated by systematically altering the pressure (552 kPa, 690 kPa, and 827 KPa) in a 20c, 23c, 25c, and 28c tyre of the same design while riding at a wheel speed of 45 kph. Average power over 1 minute was measured with a Power Tap Hub (Tune Corporation, Cambridge, Massachusetts, USA) on five occasions. Statistical significance was evaluated at p < 0.05. Power requirements increased significantly with each reduction in tyre pressure for all tyres and pressures except the 25c between 690 and 827 kPa. The 20c tyre required significantly more power from the cyclist at each tested tyre pressure when compared to the other tyres (which were not different from each other). The differences in resistance from tyre size were not observed when ridden on the road. Additionally, a slightly different tyre design from the same manufacturer responded similarly in the 20c, but was significantly different in the 23c size. It was also observed that power requirements increased significantly when both the wheels were ridden on the rollers as compared to just the rear wheel. These results indicate that the power requirements may be significantly altered by the cyclist by adjusting tyre pressure, tyre cross-section size, tyre type, and with the number of wheels contacting the rollers. However, the magnitude of these power requirements may not be suitable for intense workouts of trained cyclists.
Glogaza, Alexander; Schröder, Christian; Woiczinski, Matthias; Müller, Peter; Jansson, Volkmar; Steinbrück, Arnd
2018-06-01
Patellofemoral kinematics and retropatellar pressure distribution change after total knee arthroplasty (TKA). It was hypothesized that different TKA designs will show altered retropatellar pressure distribution patterns and different patellofemoral kinematics according to their design characteristics. Twelve fresh-frozen knee specimens were tested dynamically in a knee rig. Each specimen was measured native, after TKA with a posterior stabilized design (PS) and after TKA with a medial stabilized design (MS). Retropatellar pressure distribution was measured using a pressure sensitive foil which was subdivided into three areas (lateral and medial facet and patellar ridge). Patellofemoral kinematics were measured by an ultrasonic-based three-dimensional motion system (Zebris CMS20, Isny Germany). Significant changes in patellofemoral kinematics and retropatellar pressure distribution were found in both TKA types when compared to the native situation. Mean retropatellar contact areas were significantly smaller after TKA (native: 241.1 ± 75.6 mm 2 , MS: 197.7 ± 74.5 mm 2 , PS: 181.2 ± 56.7 mm 2 , native vs. MS p < 0.001; native vs. PS p < 0.001). The mean peak pressures were significantly higher after TKA. The increased peak pressures were however seen in different areas: medial and lateral facet in the PS-design (p < 0.001), ridge in the MS design (p < 0.001). Different patellofemoral kinematics were found in both TKA designs when compared to the native knee during flexion and extension with a more medial patella tracking. Patellofemoral kinematics and retropatellar pressure change after TKA in different manner depending on the type of TKA used. Surgeons should be aware of influencing the risks of patellofermoral complications by the choice of the prosthesis design.
Owen, Christopher G; Whincup, Peter H; Gilg, Julie A; Cook, Derek G
2003-01-01
Objective To determine whether breast feeding in infancy compared with bottle feeding formula milk is associated with lower mean blood pressure at different ages. Design Systematic review. Data sources Embase, Medline, and Web of Science databases. Study selection Studies showing the effects of feeding in infancy on blood pressure at different ages. Data extraction Pooled mean differences in blood pressure between breast fed infants and those bottle fed formula milk, based on random effects models. Data synthesis The pooled mean difference in systolic blood pressure was -1.10 mm Hg (95% confidence interval -1.79 to -0.42 mm Hg) but with significant heterogeneity between estimates (P < 0.001). The difference was largest in studies of < 300 participants (-2.05 mm Hg, -3.30 to -0.80 mm Hg), intermediate in studies of 300-1000 participants (1.13 mm Hg, -2.53 to 0.27 mm Hg), and smallest in studies of > 1000 participants (-0.16 mm Hg, -0.60 to 0.28 mm Hg). An Egger test but not Begg test was statistically significant for publication bias. The difference was unaltered by adjustment for current size and was independent of age at measurement of blood pressure and year of birth. Diastolic blood pressure was not significantly related to type of feeding in infancy. Conclusions Selective publication of small studies with positive findings may have exaggerated claims that breast feeding in infancy reduces systolic blood pressure in later life. The results of larger studies suggest that feeding in infancy has at most a modest effect on blood pressure, which is of limited clinical or public health importance. PMID:14630752
Kwon, Hae-Yeon
2017-01-01
[Purpose] The purpose of this study was to determine differences in respiratory function and pressure among three groups of children with cerebral palsy as a predominant abnormal movement which included spastic type, dyskinetic type, and ataxic type. [Subjects and Methods] Forty-three children with cerebral palsy of 5–13 years of age in I–III levels according to the Gross Motor Function Classification System, the study subjects were divided by stratified random sampling into three groups of spastic type, dyskinetic type, and ataxic type. For reliability of the measurement results, respiratory function and pressure of the children with cerebral palsy were measured by the same inspector using Spirometer Pony FX (Cosmed Ltd., Italy) equipment, and the subject’s guardians (legal representative) was always made to observe. [Results] In the respiratory function, there were significant differences among three groups in all of forced vital capacity, forced expiratory volume at one second, and peak expiratory flow. For respiratory pressure, the maximal inspiratory pressure had significant differences among three groups, although the maximal expiratory pressure had no significant difference. [Conclusion] Therefore, pediatric physical therapists could be provided with important clinical information in understanding the differences in respiratory function and pressure for the children with cerebral palsy showing predominantly abnormal movement as a diverse qualitative characteristics of the muscle tone and movement patterns, and in planning intervention programs for improvement of respiratory capacity. PMID:28265153
Extreme pressure differences at 0900 NZST and winds across New Zealand
NASA Astrophysics Data System (ADS)
Salinger, M. James; Griffiths, Georgina M.; Gosai, Ashmita
2005-07-01
Trends in extremes in station daily sea-level pressure differences at 0900 NZST are examined, and extreme daily wind gusts, across New Zealand, since the 1960s. Annual time series were examined (with indices of magnitude and frequency over threshold percentiles) from the daily indices selected. These follow from earlier indices of normalized monthly mean sea-level pressure differences between station pairs, except the daily indices are not normalized. The frequency statistics quantify the number of extreme zonal (westerly and easterly), or extreme meridional (southerly or northerly), pressure gradient events. The frequency and magnitude of extreme westerly episodes has increased slightly over New Zealand, with a significant increase in the westerly extremes to the south of New Zealand. In contrast, the magnitude and frequency of easterly extremes has decreased over New Zealand, but increased to the south, with some trends weakly significant. The frequency and magnitude of daily southerly extremes has decreased significantly in the region.Extreme daily wind gust events at key climate stations in New Zealand and at Hobart, Australia, are highly likely to be associated with an extreme daily pressure difference. The converse was less likely to hold: extreme wind gusts were not always observed on days with extreme daily pressure difference, probably due to the strong influence that topography has on localized station winds. Significant correlations exist between the frequency indices and both annual-average mean sea-level pressures around the Australasian region and annual-average sea surface temperature (SST) anomalies in the Southern Hemisphere. These correlations are generally stronger for indices of extreme westerly or extreme southerly airflows. Annual-average pressures in the Tasman Sea or Southern Ocean are highly correlated to zonal indices (frequency of extreme westerlies). SST anomalies in the NINO3 region or on either side of the South Island are significantly correlated with the frequency of extreme westerly airflows.
Goozée, Justine V; Murdoch, Bruce E; Theodoros, Deborah G
2002-01-01
A miniature pressure transducer was used to assess the interlabial contact pressures produced by a group of 19 adults (mean age 30.6 years) with dysarthria following severe traumatic brain injury (TBI) during a set of speech and nonspeech tasks. Ten parameters relating to lip strength, endurance, rate of movement and lip pressure accuracy and stability were measured from the nonspeech tasks. The results attained by the TBI group were compared against a group of 19 age- and sex-matched control subjects. Significant differences between the groups were found for maximum interlabial contact pressure, maximum rate of repetition of maximum pressure, and lip pressure accuracy at 50 and 10% levels of maximum pressure. In regards to speech, the interlabial contact pressures generated by the TBI group and control group did not differ significantly. When expressed as percentages of maximum pressure, however, the TBI group's interlabial pressures appeared to have been generated with greater physiological effort. Copyright 2002 S. Karger AG, Basel
Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard
2013-01-01
Background Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a ‘white-coat’ effect. Aim To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Design and setting Retrospective study in a teaching hospital in Birmingham. Method Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Result Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Conclusion Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the ‘white-coat’ effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm. PMID:23561681
Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard
2013-02-01
Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a 'white-coat' effect. To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Retrospective study in a teaching hospital in Birmingham. Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the 'white-coat' effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm.
Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng
2017-11-01
This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.
Inamoto, Ryuhei; Miyashita, Takenori; Matsubara, Ai; Hoshikawa, Hiroshi; Mori, Nozomu
2017-06-01
The purpose of the study was to investigate the difference in the responses of endolymphatic hydrostatic pressure to isoproterenol, β-adrenergic receptor agonist, between pars superior and pars inferior. The hydrostatic pressure of endolymph and perilymph and endolymphatic potential in the ampulla and the cochlea during the intravenous administration of isoproterenol were recorded using a servo-null system in guinea pigs. The hydrostatic pressure of endolymph and perilymph in the ampulla and cochlea was similar in magnitude. Isoproterenol significantly increased hydrostatic pressure of ampullar and cochlear endolymph and perilymph with no change in the ampullar endolymphatic potential and endocochlear potential, respectively. The isoproterenol-induced maximum change of endolymphatic hydrostatic pressure in ampulla was significantly (p<0.01) smaller than that in the cochlea. In ears with an obstructed endolymphatic sac, the action of isoproterenol on endolymphatic hydrostatic pressure in the ampulla disappeared like that in the cochlea. Isoproterenol elevates endolymphatic hydrostatic pressure in different manner between the vestibule and the cochlea. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Aeschlimann, Kimberly A; Mann, F A; Middleton, John R; Belter, Rebecca C
2018-05-01
OBJECTIVE To determine whether stored (cooled or frozen-thawed) jejunal segments can be used to obtain dependable leak pressure data after enterotomy closure. SAMPLE 36 jejunal segments from 3 juvenile pigs. PROCEDURES Jejunal segments were harvested from euthanized pigs and assigned to 1 of 3 treatment groups (n = 12 segments/group) as follows: fresh (used within 4 hours after collection), cooled (stored overnight at 5°C before use), and frozen-thawed (frozen at -12°C for 8 days and thawed at room temperature [23°C] for 1 hour before use). Jejunal segments were suspended and 2-cm enterotomy incisions were made on the antimesenteric border. Enterotomies were closed with a simple continuous suture pattern. Lactated Ringer solution was infused into each segment until failure at the suture line was detected. Leak pressure was measured by use of a digital transducer. RESULTS Mean ± SD leak pressure for fresh, cooled, and frozen-thawed segments was 68.3 ± 23.7 mm Hg, 55.3 ± 28.1 mm Hg, and 14.4 ± 14.8 mm Hg, respectively. Overall, there were no significant differences in mean leak pressure among pigs, but a significant difference in mean leak pressure was detected among treatment groups. Mean leak pressure was significantly lower for frozen-thawed segments than for fresh or cooled segments, but mean leak pressure did not differ significantly between fresh and cooled segments. CONCLUSIONS AND CLINICAL RELEVANCE Fresh porcine jejunal segments or segments cooled overnight may be used for determining intestinal leak pressure, but frozen-thawed segments should not be used.
Race and diurnal blood pressure patterns. A review and meta-analysis.
Profant, J; Dimsdale, J E
1999-05-01
Investigators have reported variable findings regarding the role of race in diurnal blood pressure patterns. We performed a review and meta-analysis of this literature to identify the overall effect of race on circadian blood pressure patterns. Eighteen studies involving 2852 participants were reviewed. Meta-analyses were conducted using effect sizes calculated from the data provided directly in the study reports. Separate meta-analyses were conducted on effect sizes for differences between blacks and whites in daytime and nighttime systolic and diastolic blood pressure and nocturnal dip in systolic and diastolic blood pressure. To evaluate discrepancies in findings from studies involving American versus non-American blacks, overall meta-analyses as well as within-subset meta-analyses of black/white differences were conducted for comparisons involving American and non-American blacks. Results of overall meta-analyses indicate that blacks experience higher levels of systolic and diastolic blood pressure, both at night and during the day. These differences were significantly greater at night than during the day (P<0.05). Results of within-subset analyses involving American blacks mirrored those for all black/white comparisons, except that the effect of race on nocturnal dip, ie, that American blacks experienced less of a dip in both systolic and diastolic blood pressure at night, was significant (P<0.05). In contrast, the effect of race on nocturnal dip was not significant for comparisons involving non-American blacks. These results suggest a consistent difference in the chronobiology of blood pressure, particularly in American blacks.
Nouman, Muhammad; Leelasamran, Wipawan; Chatpun, Surapong
2017-08-01
Using a total contact orthosis (TCO) is an effective method to offload in diabetic patients with foot neuropathy. However, the redistribution of peak plantar pressure is mostly observed during level walking, which may differ from other walking activities. The aim of this study was to investigate the plantar pressure from 4 regions of the foot during different walking activities (level walking, ramp ascending, ramp descending, stair ascending, and stair descending) in neuropathic diabetic patients with and without a TCO. Sixteen neuropathic diabetic patients aged 40 to 60 years with calluses and hallux valgus were included in this study and were provided with TCOs made up of multifoam, Plastazote, and microcellular rubber. The plantar pressure and contact area with the TCO and without the TCO were recorded using the Pedar X system during different walking activities. A significant reduction of plantar pressure during different walking activities at the toes and forefoot regions was observed while walking with the TCO compared with walking without the TCO (control condition). Plantar pressure increased at the midfoot region when walking with the TCO, and no significant difference was observed at the hindfoot region between the control and TCO conditions. Furthermore, maximum contact area was observed during level walking with the TCO compared with other walking activities. The TCO significantly reduced and redistributed the peak plantar pressure from the sites where the ulceration rate is higher at the toes and forefoot compared with the other regions of the foot. Therapeutic level II, lesser quality randomized controlled trial.
Yi, Min; Leng, Yuxin; Bai, Yu; Yao, Gaiqi; Zhu, Xi
2012-04-01
Current literatures confirmed the widespread and frequent development of both intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) among the critically ill with a significant associated risk of organ failure and increased mortality. The 2004 International ACS Consensus Conference committee proposed that intra-abdominal pressure (IAP) be measured in complete supine position; however, the supine position of intensive care unit (ICU) patients (<30° of bed increase) presented a significant risk for ventilator-associated pneumonia. Therefore, the potential contribution of head of bed (HOB) position in elevating IAP should be considered. The purpose of this study was to evaluate the effect of body positioning on IAP measurement and the effect of IAP at different body positions on organ function and prognosis in critically ill patients. A prospective cohort study to investigate the effect of different patient positioning on IAP, organ function, and prognosis was conducted on 88 patients admitted to a medical-surgical ICU. On admission, patients' epidemiological data and risk factors for IAH were studied; daily mean IAPs, abdominal perfusion pressure, filtration gradient, Acute Physiology and Chronic Health Evaluation II score, sequential organ failure assessment score, and multiple organ dysfunction scores were registered; next, conventional hemodynamic variables, intrathoracic blood volume index, global end-diastolic volume index and extravascular lung water using the pulse contour cardiac output system were recorded. Intra-abdominal pressures were recorded through a bladder catheter every 4 hours on the first day. Intra-abdominal pressure was measured with the patient HOB increases from 0° to 45°. Mean arterial pressure was recorded simultaneously, whereas abdominal perfusion pressure and filtration gradient (FG) were also calculated simultaneously. The main results of this study were the incidence of IAH (28.4%) and ACS (2.3%) in ICU patients; the significant and independent relationship between IAP and HOB increases. Considering the absolute numbers of IAP, the HOB of 10° and 20° showed slight differences, whereas that of 30° and 45° showed clinically significant differences; HOB elevation was associated with clinically significant decreases in abdominal perfusion pressure and FG; patients with IAH were prone to the development of shock and multiple organ dysfunction syndrome and exhibited significantly lower intrathoracic blood volume index and global end-diastolic volume index and higher extravascular lung water. There is a significant and independent relationship between IAP and HOB positioning in critically ill patients, with the HOB of 30° and 45° showing significant difference. Abdominal perfusion pressure and FG are significantly decreased when the patient's HOB is elevated. The potential contribution of body position in elevating IAP should be considered in critically ill patients with the risk of IAH and ACS. Copyright © 2012 Elsevier Inc. All rights reserved.
Komori, Yoko; Iwashita, Yukio; Ohta, Masayuki; Kawano, Yuichiro; Inomata, Masafumi; Kitano, Seigo
2014-08-01
A recent study demonstrated that high pressure of carbon dioxide (CO2) pneumoperitoneum before liver resection impairs postoperative liver regeneration. This study was aimed to investigate effects of varying insufflation pressures of CO2 pneumoperitoneum on liver regeneration using a rat model. 180 male Wistar rats were randomly divided into three groups: control group (without preoperative pneumoperitoneum), low-pressure group (with preoperative pneumoperitoneum at 5 mmHg), and high-pressure group (with preoperative pneumoperitoneum at 10 mmHg). After pneumoperitoneum, all rats were subjected to 70% partial hepatic resection and then euthanized at 0 min, 12 h, and on postoperative days (PODs) 1, 2, 4, and 7. Following outcome parameters were used: liver regeneration (liver regeneration rate, mitotic count, Ki-67 labeling index), hepatocellular damage (serum aminotransferases), oxidative stress [serum malondialdehyde (MDA)], interleukin-6 (IL-6), and hepatocyte growth factor (HGF) expression in the liver tissue. No significant differences were observed for all parameters between control and low-pressure groups. The liver regeneration rate and mitotic count were significantly decreased in the high-pressure group than in control and low-pressure groups on PODs 2 and 4. Postoperative hepatocellular damage was significantly greater in the high-pressure group on PODs 1, 2, 4, and 7 compared with control and/or low-pressure groups. Serum MDA levels were significantly higher in the high-pressure group on PODs 1 and 2, and serum IL-6 levels were significantly higher in the high-pressure group at 12 h and on POD 1, compared with control and/or low-pressure groups. The HGF tissue expression was significantly lower in the high-pressure group at 12 h and on PODs 1 and 4, compared with that in control and/or low-pressure groups. High-pressure pneumoperitoneum before 70% liver resection impairs postoperative liver regeneration, but low-pressure pneumoperitoneum has no adverse effects. This study suggests that following laparoscopic liver resection using appropriate pneumoperitoneum pressure, no impairment of liver regeneration occurs.
Zhang, C; Xu, J-M; Kong, D-R; Min, X-K; Chen, R
2013-06-01
Somatostatin (SST) is used for the treatment of acute variceal bleeding based on its ability to decrease portal pressure and collateral blood flow. To date, no studies have focused on the immediate-early effects (between 1 and 30 min) of SST. The aim of this study was to compare the efficacy of different schedules of SST therapy with placebo on portal pressure in patients with portal hypertension treated with portal-azygous disconnection and to test whether an increase in bolus or infusion dose can improve the clinical efficacy of SST therapy. Patients were treated with four different schedules: (a) standard dose (n = 11): one 250 μg bolus + a continuous infusion of 250 μg/h; (b) medium dose (n = 10): 500 μg bolus + a continuous infusion of 250 μg/h; (c) high dose (n = 10): 250 μg bolus + a continuous infusion of 500 μg/h; (d) control (n = 10): an injection of placebo (saline) followed by a placebo infusion. Following SST or placebo administration, portal pressure, central venous pressure (CVP), systemic blood pressure and heart rate (HR) were measured at 1, 3, 5, 7, 10 and 30 min. The three schedules of SST induced a marked, rapid and highly significant decrease in portal pressure. The decline in portal pressure was moderate at 1 min (P < 0·040), achieved a peak effect at 5 min (P < 0·009) and remained decreased at 30 min. The effect of SST on portal pressure was significantly greater than placebo from 1 min after administration. There were no significant differences in portal pressure decrease between the three schedules of SST. The three schedules of SST and the placebo schedule did not induce significant changes in HR, systemic blood pressure and CVP. This study shows that SST is effective in decreasing portal pressure within 30 min of administration in patients with liver cirrhosis. The clinical schedule used in this study was reasonable and safe. © 2013 Blackwell Publishing Ltd.
Weinberg, Ido; Gona, Philimon; O'Donnell, Christopher J; Jaff, Michael R; Murabito, Joanne M
2014-03-01
An increased interarm systolic blood pressure difference is an easily determined physical examination finding. The relationship between interarm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of interarm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between interarm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. An increased interarm systolic blood pressure difference was defined as ≥ 10 mm Hg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of interarm systolic blood pressure difference on incident cardiovascular disease. We examined 3390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute interarm systolic blood pressure difference was 4.6 mm Hg (range 0-78). Increased interarm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event, including 83 (26.2%) participants with interarm systolic blood pressure difference ≥ 10 mm Hg. Compared with those with normal interarm systolic blood pressure difference, participants with an elevated interarm systolic blood pressure difference were older (63.0 years vs 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs 7.5%,), higher systolic blood pressure (136.3 mm Hg vs 129.3 mm Hg), and a higher total cholesterol level (212.1 mg/dL vs 206.5 mg/dL). Interarm systolic blood pressure difference was associated with a significantly increased hazard of incident cardiovascular events in the multivariable adjusted model (hazard ratio 1.38; 95% CI, 1.09-1.75). For each 1-SD-unit increase in absolute interarm systolic blood pressure difference, the hazard ratio for incident cardiovascular events was 1.07 (95% CI, 1.00-1.14) in the fully adjusted model. There was no such association with mortality (hazard ratio 1.02; 95% CI 0.76-1.38). In this community-based cohort, an interarm systolic blood pressure difference is common and associated with a significant increased risk for future cardiovascular events, even when the absolute difference in arm systolic blood pressure is modest. These findings support research to expand clinical use of this simple measurement. Copyright © 2014 Elsevier Inc. All rights reserved.
Matsuyama, N; Takano, K; Mashiko, T; Jimbo, S; Shimetani, N; Ohtani, H
1999-11-01
To test the hypothesis that acute inflammatory reaction associates with the development of pressure ulcers in bedridden elderly patients, 40 hospitalized elderly patients suffering from bacterial pneumonia, cerebrovascular disease, and femoral bone fracture were enrolled in this study. All of them were divided into two groups with pressure ulcers (group P; 17 patients) and without one (group N; 23 patients). The blood samples were taken from them within 5 days after the patients being bedridden. Although no significant difference exist in pressure ulcer risk factors (age, gender, Braden scale, underlying diseases, blood pressure, and heart rate) between the two groups, white blood cell, plasma C-reactive protein and fibrinogen in group P increased significantly as compared with those in group N. Besides number of platelets and maximum platelet aggregation rate were significantly higher in group P than in group N. Serum albumin and hemoglobin of both groups decreased after being bedridden, especially hemoglobin in group P was significantly lower than that in group N. While the concentration of serum IL-6 did not indicate a significant difference between both the groups, serum IL-1 beta increased significantly in group P. In conclusion, we suggested that acute inflammatory reaction releasing proinflammatory cytokines affected the development of pressure ulcer in bedridden elderly patients.
Van den Kerckhove, Eric; Stappaerts, Karel; Fieuws, Steffen; Laperre, Jan; Massage, Patrick; Flour, Mieke; Boeckx, Willy
2005-09-01
The aim of this study was threefold: (1) Assess the pressure loss of two types of pressure garments that are used in the treatment of hypertrophic scars after burn injury, (2) investigate the influence of two different levels of compression on erythema and thickness of burn scars and (3) examine the association between erythema and thickness. The study was a prospective trial in which 76 burn scars in 60 patients were objectively assessed with the Minolta Chromameter CR-300 for erythema and with the Dermascan C for thickness of the scar over a period of 3 months. Each patient was randomly assigned to a "normal" or "lower" compression class treatment, with respectively mean values of 15 and 10 mmHg pressure after wearing the garment for 1 month. Measurements for both parameters were taken at 0, 1, 2 and 3 months of treatment. Pressure garments with "normal" compression did lose significantly more compression over 1 month (4.82 mmHg) than did the garments from the low compression class (2.57 mmHg). Scars that were treated with garments from a "normal" compression class did score significantly better for thickness compared to the "low" compression class. The difference in thickness was most evident at 1 month. Thereafter no further significant improvement between the two different treatments over time could be obtained. This difference was not found for erythema. Positive correlations could be found between erythema and thickness values at all of the three test points while changes in erythema and thickness only correlated significantly after the first month. The pattern of change of both parameters correlated at a high level of significance after 3 months of treatment. These data suggest that pressure garments that deliver a pressure of at least 15 mmHg pressure tend to accelerate scar maturation and that measurements of the pattern of change of the erythema can be used to predict changes in scar thickness and vice versa.
[Experimental study on spectra of compressed air microwave plasma].
Liu, Yong-Xi; Zhang, Gui-Xin; Wang, Qiang; Hou, Ling-Yun
2013-03-01
Using a microwave plasma generator, compressed air microwave plasma was excited under 1 - 5 atm pressures. Under different pressures and different incident microwave power, the emission spectra of compressed air microwave plasma were studied with a spectra measuring system. The results show that continuum is significant at atmospheric pressure and the characteristic will be weakened as the pressure increases. The band spectra intensity will be reduced with the falling of the incident microwave power and the band spectra were still significant. The experimental results are valuable to studying the characteristics of compressed air microwave plasma and the generating conditions of NO active groups.
Urinary Metabolites Associated with Blood Pressure on a Low- or High-Sodium Diet
Cheng, Yuan; Song, Haiying; Pan, Xiaoqing; Xue, Hong; Wan, Yifei; Wang, Tao; Tian, Zhongmin; Hou, Entai; Lanza, Ian R.; Liu, Pengyuan; Liu, Yong; Laud, Purushottam W.; Usa, Kristie; He, Yongcheng; Liang, Mingyu
2018-01-01
Dietary salt intake has significant effects on arterial blood pressure and the development of hypertension. Mechanisms underlying salt-dependent changes in blood pressure remain poorly understood, and it is difficult to assess blood pressure salt-sensitivity clinically. Methods: We examined urinary levels of metabolites in 103 participants of the Dietary Approaches to Stop Hypertension (DASH)-Sodium trial after nearly 30 days on a defined diet containing high sodium (targeting 150 mmol sodium intake per day) or low sodium (50 mmol per day). Targeted chromatography/mass spectrometry analysis was performed in 24 h urine samples for 47 amino metabolites and 10 metabolites related to the tricarboxylic acid cycle. The effect of an identified metabolite on blood pressure was examined in Dahl salt-sensitive rats. Results: Urinary metabolite levels improved the prediction of classification of blood pressure salt-sensitivity based on race, age and sex. Random forest and generalized linear mixed model analyses identified significant (false discovery rate <0.05) associations of 24 h excretions of β-aminoisobutyric acid, cystine, citrulline, homocysteine and lysine with systolic blood pressure and cystine with diastolic blood pressure. The differences in homocysteine levels between low- and high-sodium intakes were significantly associated with the differences in diastolic blood pressure. These associations were significant with or without considering demographic factors. Treatment with β-aminoisobutyric acid significantly attenuated high-salt-induced hypertension in Dahl salt-sensitive rats. Conclusion: These findings support the presence of new mechanisms of blood pressure regulation involving metabolic intermediaries, which could be developed as markers or therapeutic targets for salt-sensitive hypertension. PMID:29556335
Urinary Metabolites Associated with Blood Pressure on a Low- or High-Sodium Diet.
Cheng, Yuan; Song, Haiying; Pan, Xiaoqing; Xue, Hong; Wan, Yifei; Wang, Tao; Tian, Zhongmin; Hou, Entai; Lanza, Ian R; Liu, Pengyuan; Liu, Yong; Laud, Purushottam W; Usa, Kristie; He, Yongcheng; Liang, Mingyu
2018-01-01
Dietary salt intake has significant effects on arterial blood pressure and the development of hypertension. Mechanisms underlying salt-dependent changes in blood pressure remain poorly understood, and it is difficult to assess blood pressure salt-sensitivity clinically. Methods: We examined urinary levels of metabolites in 103 participants of the Dietary Approaches to Stop Hypertension (DASH)-Sodium trial after nearly 30 days on a defined diet containing high sodium (targeting 150 mmol sodium intake per day) or low sodium (50 mmol per day). Targeted chromatography/mass spectrometry analysis was performed in 24 h urine samples for 47 amino metabolites and 10 metabolites related to the tricarboxylic acid cycle. The effect of an identified metabolite on blood pressure was examined in Dahl salt-sensitive rats. Results: Urinary metabolite levels improved the prediction of classification of blood pressure salt-sensitivity based on race, age and sex. Random forest and generalized linear mixed model analyses identified significant (false discovery rate <0.05) associations of 24 h excretions of β-aminoisobutyric acid, cystine, citrulline, homocysteine and lysine with systolic blood pressure and cystine with diastolic blood pressure. The differences in homocysteine levels between low- and high-sodium intakes were significantly associated with the differences in diastolic blood pressure. These associations were significant with or without considering demographic factors. Treatment with β-aminoisobutyric acid significantly attenuated high-salt-induced hypertension in Dahl salt-sensitive rats. Conclusion: These findings support the presence of new mechanisms of blood pressure regulation involving metabolic intermediaries, which could be developed as markers or therapeutic targets for salt-sensitive hypertension.
Foot Type Biomechanics Part 1: Structure and Function of the Asymptomatic Foot
Hillstrom, Howard J.; Song, Jinsup; Kraszewski, Andrew P.; Hafer, Jocelyn F.; Mootanah, Rajshree; Dufour, Alyssa B.; PT, Betty (Shingpui) Chow; Deland, Jonathan T.
2012-01-01
Background Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? Aim To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Methods Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMatII gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pairwise comparisons. Results Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Conclusions Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. PMID:23107625
Foot type biomechanics part 1: structure and function of the asymptomatic foot.
Hillstrom, Howard J; Song, Jinsup; Kraszewski, Andrew P; Hafer, Jocelyn F; Mootanah, Rajshree; Dufour, Alyssa B; Chow, Betty Shingpui; Deland, Jonathan T
2013-03-01
Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMat II gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pair wise comparisons. Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. Copyright © 2012 Elsevier B.V. All rights reserved.
Milani, Amin S; Zand, Vahid; Abdollahi, Amir A; Froughreyhani, Mohammad; Zakeri-Milani, Parvin; Jafarabadi, Mohammad A
2016-07-01
This study compared the effect of local pressure and topical lidocaine-prilocaine (EMLA) cream on pain during infiltration injection for maxillary canine teeth. A total of 140 volunteer students participated in this split-mouth design randomized clinical trial. The subjects were randomly divided into four groups (n = 35). Before administration of anesthesia, in each group, one side was randomly selected as the experimental and the opposite side as the control. In group 1, finger pressure was applied on the alveolar mucosa on the experimental side and on the tooth crown on the control side. In group 2, 5% EMLA cream and placebo; in group 3, finger pressure and 5% EMLA cream; and in group 4, 5% EMLA cream and 20% benzocaine gel were applied. In all the groups, a buccal infiltration procedure was carried out. Pain during injection was recorded with visual analog scale (VAS). Wilcoxon and McNemar tests were used for statistical analysis of the results. Statistical significance was set at p < 0.05. The results showed that EMLA reduced the injection pain significantly more than benzocaine (p = 0.02). Also, injection pain was significantly lower with the use of EMLA in comparison to placebo (p = 0.00). Application of local pressure reduced the injection pain, but the difference from the control side was not significant (p = 0.05). Furthermore, the difference between application of local pressure and EMLA was not statistically significant (p = 0.08). Topical anesthesia of 5% EMLA was more effective than 20% benzocaine in reducing pain severity during infiltration injection. However, it was not significantly different in comparison to the application of local pressure.
Distribution of Blood Pressure Data from People Living Near AN Airport
NASA Astrophysics Data System (ADS)
GOTO, K.; KANEKO, T.
2002-02-01
We observed blood pressure in general health examination data around a city airport and compared the data with those from a calm suburban area of the city. Information was also collected on the short-term history of medication and lifestyle including smoking, drinking and eating salty foods. This cross-sectional study on 469 women showed that systolic and diastolic blood pressure was not associated with aircraft noise levels in the area, even after controlling for variables regarding anti-hypertension treatment and lifestyle factors. A comparative study on 469 women from an area around an airport and 1177 women from a suburban control area showed no significant differences between blood pressure and other medical tests controlling for the variables of medication and lifestyle. Changes in blood pressure after 8 years were observed in 183 women around the airport. No significant differences among three zones with different levels of aircraft noise were found.
Variation of plantar pressure in Chinese diabetes mellitus.
Yang, Chuan; Xiao, Huisheng; Wang, Chuan; Mai, LiFang; Liu, Dan; Qi, Yiqing; Ren, Meng; Yan, Li
2015-01-01
To investigate dynamic changes in plantar pressure in Chinese diabetes mellitus patients and to provide a basis for further preventing diabetic foot. This is a cross-sectional investigation including 649 Chinese diabetes mellitus patients (diabetes group) and 808 "normal" Chinese persons (nondiabetes group) with normal blood glucose levels. All the subjects provided a complete medical history and underwent a physical examination and a 75-g oral glucose tolerance test. All subjects walked barefoot with their usual gait, and their dynamic plantar forces were measured using the one-step method with a plantar pressure measurement instrument; 5 measurements were performed for each foot. No significant differences were found in age, height, body weight, or body mass index between the two groups. The fasting blood glucose levels, plantar contact time, maximum force, pressure-time integrals and force-time integrals in the diabetes group were significantly higher than those in the nondiabetes group (p < 0.05). However, the maximum pressure was significantly higher in the nondiabetes group than in the diabetes group (p < 0.05). No difference was found in the contact areas between the two groups (p > 0.05). The maximum plantar force distributions were essentially the same, with the highest force found for the medial heel, followed by the medial forefoot and the first toe. The peak plantar pressure was located at the medial forefoot for the nondiabetes group and at the hallucis for the diabetes group. In the diabetes group, the momentum in each plantar region was higher than that in the nondiabetes group; this difference was especially apparent in the heel, the lateral forefoot and the hallucis. The dynamic plantar pressures in diabetic patients differ from those in nondiabetic people with increased maximum force and pressure, a different distribution pattern and significantly increased momentum, which may lead to the formation of foot ulcers. © 2015 by the Wound Healing Society.
Kuczera, Piotr; Kwiecień, Katarzyna; Adamczak, Marcin; Bączkowska, Teresa; Gozdowska, Jolanta; Madziarska, Katarzyna; Augustyniak-Bartosik, Hanna; Klinger, Marian; Durlik, Magdalena; Ritz, Eberhard; Wiecek, Andrzej
2018-05-10
Arterial hypertension is one of the leading factors aggravating the course of chronic kidney disease (CKD). It seems that the novel parameters used in the assessment of the blood pressure (BP) load (i.e. central blood pressure, nighttime blood pressure) may be more precise in predicting the cardiovascular risk and the progression of CKD in comparison with the traditional peripheral blood pressure measurements in the office conditions. The aim of the study was to assess the impact of the central, or nighttime blood pressure on the progression of CKD in patients with mild or no-proteinuria (autosomal, dominant polycystic kidney disease or IgA nephropathy). In each of the enrolled 46 patients with CKD stage 3 or 4, serum creatinine concentration was assessed, eGFR (MDRD) was calculated, also central blood pressure and pulse wave velocity (PWV) was assessed and the 24-hour ambulatory blood pressure monitoring (ABPM) was conducted at the beginning of the study and then repeated after one-year observation period. During the observation period mean eGFR decreased from 44.1 (33.2-50.6) mL/min to 36.7 (29.7-46.3) mL/min. No significant differences were observed in the peripheral blood pressure or central blood pressure parameters. After one-year observation period the values of diastolic blood pressure dipping during the night significantly decreased from 16 (13-19) mmHg to 12 (10-15) mmHg; p< 0.05. The values of systolic dipping during the night or the mean BP values recorded in ABPM did not change significantly. Additionally, no significant differences in the PWV values were found. In the multivariate regression model the change of serum creatinine concentration was explained by the initial diastolic dipping values. 1. In patients with CKD stages 3 or 4 and mild or no- proteinuria, peripheral and central blood pressure did not change significantly during a one-year observation period despite the significant decline of eGFR and seems not to participate in the CKD progression. 2. Reduced magnitude of the diastolic dipping, which reflects the increase of diastolic blood pressure load during the nighttime, may play an important role in the pathogenesis of deterioration of kidney function in these patients. © 2018 The Author(s). Published by S. Karger AG, Basel.
Hematological change parameters in patients with pressure ulcer at long-term care hospital
Neiva, Giselle Protta; Carnevalli, Julia Romualdo; Cataldi, Rodrigo Lessa; Furtado, Denise Mendes; Fabri, Rodrigo Luiz; Silva, Pâmela Souza
2014-01-01
Objective To assess factors associated with the development of pressure ulcers, and to compare the effectiveness of pharmacological treatments. Methods The factors associated with the development of pressure ulcers were compared in lesion-carrying patients (n=14) and non-carriers (n=16). Lesion-carrying patients were treated with 1% silver sulfadiazine or 0.6IU/g collagenase and were observed for 8 weeks. The data collected was analyzed with p<0.05 being statistically relevant. Results The prevalence of pressure ulcers was about 6%. The comparison of carrier and non-carrier groups of pressure ulcers revealed no statistically significant difference in its occurrence with respect to age, sex, skin color, mobility, or the use of diapers. However, levels of hemoglobin, hematocrit, and red blood cells were found to be statistically different between groups, being lower in lesion-carrying patients. There was no significant difference found in lesion area between patients treated with collagenase or silver sulfadiazine, although both groups showed an overall reduction in lesion area through the treatment course. Conclusion Hematologic parameters showed a statistically significant difference between the two groups. Regarding the treatment of ulcers, there was no difference in the area of the lesion found between the groups treated with collagenase and silver sulfadiazine. PMID:25295450
Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.
2013-01-01
Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; p<0.001). However, there was no difference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809
Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M
2013-06-12
To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; p<0.001). However, there was no difference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.
Sonenblum, Sharon E; Vonk, Teddie E; Janssen, Thomas W; Sprigle, Stephen H
2014-07-01
To investigate the effectiveness and interactions of 2 methods of pressure ulcer prevention, wheelchair cushions and pressure relief maneuvers, on interface pressure (IP) and blood flow of the buttocks. Within-subject repeated measures. Rehabilitation center. Wheelchair users with a spinal cord injury or disorder (N=17). Participants performed 3 forward leans and 2 sideward leans with different degrees of lean while seated on each of 3 different wheelchair cushions. IP measured with a custom sensor and blood flow measured with laser Doppler flowmetry were collected at the ischial tuberosity. Pressure relief maneuvers had a significant main effect on the ischial IP (P<.001); all maneuvers except for the small frontward lean resulted in a significant reduction in IP compared with upright sitting. Blood flow significantly varied across postures (P<.001) with flow during upright sitting and small forward leans being significantly lower than during the full and intermediate leans in both the forward and sideward directions. The results of the study highlight the importance of positioning wheelchair users in a manner that facilitates in-seat movement. Regardless of the cushion being used, the pressure relief maneuvers resulted in very large reductions in IPs and significant increases in buttock blood flow. Only the small frontward lean was shown to be ineffective in reducing pressure or increasing blood flow. Because these pressure relief maneuvers involved postural changes that can occur during functional activities, these pressure relief maneuvers can become a part of volitional pressure relief and functional weight shifts. Therefore, clinical instruction should cover both as a means to impart sitting behaviors that may lead to better tissue health. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
The position of the arm during blood pressure measurement in sitting position.
Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo
2006-12-01
Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.
Tomiyama, Hirofumi; Ohkuma, Toshiaki; Ninomiya, Toshiharu; Mastumoto, Chisa; Kario, Kazuomi; Hoshide, Satoshi; Kita, Yoshikuni; Inoguchi, Toyoshi; Maeda, Yasutaka; Kohara, Katsuhiko; Tabara, Yasuharu; Nakamura, Motoyuki; Ohkubo, Takayoshi; Watada, Hirotaka; Munakata, Masanori; Ohishi, Mitsuru; Ito, Norihisa; Nakamura, Michinari; Shoji, Tetsuo; Vlachopoulos, Charalambos; Yamashina, Akira
2018-06-01
We conducted individual participant data meta-analysis to examine the validity of interarm blood pressure difference in simultaneous measurement as a marker to identify subjects with ankle-brachial pressure index <0.90 and to predict future cardiovascular events. We collected individual participant data on 13 317 Japanese subjects from 10 cohorts (general population-based cohorts, cohorts of patients with past history of cardiovascular events, and those with cardiovascular risk factors). Binary logistic regression analysis with adjustments identified interarm blood pressure difference >5 mm Hg as being associated with a significant odds ratio for the presence of ankle-brachial pressure index <0.90 (odds ratio, 2.19; 95% confidence interval, 1.60-3.03; P <0.01). Among 11 726 subjects without a past history of cardiovascular disease, 249 developed stroke during the average follow-up period of 7.4 years. Interarm blood pressure difference >15 mm Hg was associated with a significant Cox stratified adjusted hazard ratio for subsequent stroke (hazard ratio, 2.42; 95% confidence interval, 1.27-4.60; P <0.01). Therefore, interarm blood pressure differences, measured simultaneously in both arms, may be associated with vascular damage in the systemic arterial tree. These differences may be useful for identifying subjects with an ankle-brachial pressure index of <0.90 in the overall study population, and also a reliable predictor of future stroke in subjects without a past history of cardiovascular disease. These findings support the recommendation to measure blood pressure in both arms at the first visit. © 2018 American Heart Association, Inc.
Effects of varying pulsatile lavage pressure on cancellous bone structure and fracture healing.
Polzin, Britton; Ellis, Thomas; Dirschl, Douglas R
2006-04-01
To study the effects of variations in pulsatile lavage irrigation pressure on the rate of new bone formation and the degree to which cellular elements are removed from cancellous bone after fracture. A previously described intraarticular fracture model was used for 29 New Zealand white rabbits that underwent osteotomy of the medial femoral condyle. Fractures were irrigated with high-pressure pulsatile lavage at a fixed distance and volume, but at nozzle pressures varying from 20 to 70 psi. Fractures were reduced and stabilized, and animals euthanized 14 days after fracture. Fluorescent bone staining was used to determine the rate of new bone formation in the osteotomy site. At the time of euthanasia, the nonoperated knees of 12 rabbits underwent osteotomy and irrigation using the same protocol. These specimens were sent for immediate scanning electron microscopy to determine the amount of cellular material removed from the bony trabeculae. In the first week after irrigation, there was no significant difference in the amount of new bone formation between the 20- and 30-psi groups, but there were significant differences between these groups and the 50- and 70-psi groups. There were no significant differences between any of the groups in the amount of new bone formed during the second week after irrigation. No structural damage to the bony trabeculae was observed in any specimen irrigated at any of the pressures used. There was a direct correlation between percentage of the trabecula completely cleared of cellular material and irrigation pressure; there were statistically significant differences between each of the groups. There are presently no recommended guidelines as to the optimal irrigation pressure, and this study is the first to address the effects of variations in pressure on bone healing. The results of this study indicate that early new bone formation in an intraarticular fracture rabbit model is inhibited by irrigation pressure of 50 psi or greater. Additionally, this study demonstrates a direct relationship between irrigation pressure and the amount of cellular material removed from the trabecula at the irrigation site. Surgeons should be aware of the potentially detrimental effects of using irrigation pressures at or above 50 psi in the treatment of fractures.
Job demand and cardiovascular disease risk factor in white-collar workers.
Song, Young Kyu; Lee, Kang Koo; Kim, Hyoung Ryoul; Koo, Jung-Wan
2010-01-01
This study was conducted to determine whether job demand played a role as a risk factor of cardiovascular diseases by comparing changes of blood pressure, heart rate and rate pressure product (RPP) showing myocardial oxygen consumption (MVO2) according to levels of job demand. This cross-sectional study divided 177 male white-collar workers without a cardiovascular or metabolic disease according to their job demand and analyzed their body composition and results of graded exercise testing. There was no significant difference in height, body weight, body mass index (BMI), waist to hip ratio (WHR) and body fat percentage according to job demand. Maximal oxygen consumption (VO2max) and anaerobic threshold (AT) also did not show a significant difference. However, systolic blood pressures at the seventh and eighth stages over AT during exercise were significantly different and RPP was found to have a significant difference overall according to the job demand (p<0.05). These results meant that job demand affected systolic pressure in physical activities or at exercise intensity over AT and reduced energy efficiency of myocardium during physical activities. The results suggest that high job demand may be a risk factor of cardiovascular diseases.
Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark
2018-05-01
Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Impact of calibration on estimates of central blood pressures.
Soender, T K; Van Bortel, L M; Møller, J E; Lambrechtsen, J; Hangaard, J; Egstrup, K
2012-12-01
Using the Sphygmocor device it is recommended that the radial pressure wave is calibrated for brachial systolic blood pressure (SBP) and diastolic blood pressure (DBP). However it has been suggested that brachial-to-radial pressure amplification causes underestimation of central blood pressures (BPs) using this calibration. In the present study we examined if different calibrations had an impact on estimates of central BPs and on the clinical interpretation of our results. On the basis of ambulatory BP measurements, patients were categorized into patients with controlled, uncontrolled or resistant hypertension. We first calibrated the radial pressure wave as recommended and afterwards recalibrated the same pressure wave using brachial DBP and calculated mean arterial pressure. Recalibration of the pressure wave generated significantly higher estimates of central SBP (P=0.0003 and P<0.0001 at baseline and P=0.0001 and P=0.0002 after 6 months). Using recommended calibration we found a significant change in central SBP in both treatment groups (P=0.05 and P=0.01), however, after recalibrating significance was lost in patients with resistant hypertension (P=0.15). We conclude that calibration with DBP and mean arterial pressure produces higher estimates of central BPs than recommended calibration. The present study also shows that this difference between the two calibration methods can produce more than a systematic error and has an impact on interpretation of clinical results.
Outcome analysis of hemoglobin A1c, weight, and blood pressure in a VA diabetes education program.
North, Susan L; Palmer, Glen A
2015-01-01
To determine the effect of a specific diabetes education class (Basics) on hemoglobin A1c values, weight, and systolic blood pressure. In this retrospective study, the researchers compared 2 groups of male veterans with a recent diagnosis of type 2 diabetes. One group received diabetes group education (n = 175) over a 4-month period, and the other received standard diabetes management follow-up (n = 184). Outpatient clinic setting in the Midwest. Basics class compared with standard level of care. Pre- and post-laboratory values for hemoglobin A1c, weight, and systolic blood pressure. Multivariate analysis of covariance and follow-up univariate statistics for significant differences. Findings revealed significant differences in hemoglobin A1c (P < .001) and weight (P < .001) in the treatment group compared with the control group. No significant difference was found in systolic blood pressure readings between the 2 groups. There was a significant difference in weight change between groups, with the treatment group demonstrating greater weight loss. There was an association between participation in the Basics diabetes education curriculum and reduction of hemoglobin A1c values. Some participants also had added benefit of significant weight loss. Published by Elsevier Inc.
Lai, Hung-Yi; Lee, Ching-Hsin; Lee, Ching-Yi
2016-01-01
For patients suffering from primary brain injury, monitoring intracranial pressure alone is not enough to reflect the dynamic intracranial condition. In our previous study, a segment of the pressure-volume curve can be expressed by the parabolic regression model with single indicator "a". The aim of this study is to evaluate if the indicator "a" can reflect intracranial conditions. Patients with traumatic brain injury, spontaneous intracranial hemorrhage, and/or hydrocephalus who had external ventricular drainage from January 2009 to February 2010 were included. The successive volume pressure response values were obtained by successive drainage of cerebral spinal fluid from intracranial pressure 20-25 mm Hg to 10 mm Hg. The relationship between withdrawn cerebral spinal fluid volume and intracranial pressure was analyzed by the parabolic regression model with single parameter "a". The overall mean for indicator "a" was 0.422 ± 0.046. The mean of "a" in hydrocephalus was 0.173 ± 0.024 and in severe intracranial mass with slender ventricle, it was 0.663 ± 0.062. The two extreme intracranial conditions had a statistical significant difference (p<0.001). The indicator "a" of a pressure-volume curve can reflect the dynamic intracranial condition and is comparable in different situations. A significantly larger indicator "a" with increased intracranial pressure is always observed in severe intracranial mass lesions with cerebral edema. A significantly smaller indicator "a" with increased intracranial pressure is observed in hydrocephalus. Brain computed tomography should be performed early if a rapid elevation of indicator "a" is detected, as it can reveal some ongoing intracranial pathology prior to clinical deterioration. Increased intracranial pressure was frequently observed in patients with intracranial pathology. The progression can be differentiated using the pattern of the volume pressure indicator.
Oosterlinck, M; Pille, F; Back, W; Dewulf, J; Gasthuys, F
2011-10-01
The aim of this study was to evaluate the association between fore- and hind-hoof contact area and limb loading. Data from a previous study on forelimb loading and symmetry were compared with data on hindlimb kinetics, and the fore- and hind-hoof contact area at the walk and trot was evaluated. Five sound ponies, selected for symmetrical feet, were walked and trotted over a pressure plate embedded in a custom-made runway. The hindlimb peak vertical force (PVF) and vertical impulse (VI) were found to be significantly lower than in the forelimb, whereas their high symmetry ratios (>95%) did not show a significant difference from forelimb data. Hindlimb PVF in ponies was found to be slightly higher when compared to data reported for horses even though the ponies moved at a similar or lower relative velocity. The contact area had low intra-individual variability and was significantly smaller in the hind- than in the fore-hooves. A larger contact area was significantly associated with lower peak vertical pressure (PVP) but higher PVF and VI. No significant differences between left and right sides were found for contact area or loading variables. Pressure plate measurements demonstrated a significant association between hoof contact area and limb loading, in addition to intrinsic differences between fore and hindlimb locomotor function. The pressure plate provides the clinician with a tool to quantify simultaneously contralateral differences in hoof contact area and limb loading. Copyright © 2010 Elsevier Ltd. All rights reserved.
Shaikh, Wasim A; Patel, Minal C; Singh, S K
2011-01-01
The current study was conducted to determine how physical activity level and physical fitness affects the blood pressure profile of Gujarati Indian adolescents so as to help in developing preventive strategies for the local population as ethnic differences exist in the aetiopathogenesis of hypertension. A cross-sectional study was conducted on 485 Gujarati Indian adolescent boys and girls of age group 16-19 years. Physical activity level was assessed using Johnson Space Center/NASA Physical Activity Rating Scale and VO2 max was used to assess the physical fitness. Body composition was assessed in terms of Body Mass Index, Fat Mass Index and Waist Circumference. Blood Pressure was measured by oscillometry. One-way ANOVA was used to study if any significant differences (P<0.05) existed in the blood pressure profile between the high, moderate and low physical activity groups. Pearson's correlation coefficient was determined to assess the relationship between VO2 max and blood pressure profile. In girls, physical activity level was not found to have a significant effect on the blood pressure profile. In boys, systolic blood pressure and mean arterial pressure were found to be significantly higher in Moderate Physical Activity Group as compared to Low Physical Activity Group. PVO2 max was found to have a significant negative correlationship with SBP, DBP and MAP in girls and a significant negative correlationship with SBP, PP and MAP in boys. It could thus be concluded that a better physical fitness rather than a higher physical activity level could keep the blood pressure in check in the Gujarati Indian adolescents.
Kamiński, Marek; Cieślik-Guerra, Urszula I; Kotas, Rafał; Mazur, Piotr; Marańda, Witold; Piotrowicz, Maciej; Sakowicz, Bartosz; Napieralski, Andrzej; Trzos, Ewa; Uznańska-Loch, Barbara; Rechciński, Tomasz; Kurpesa, Małgorzata
2016-01-01
Atmospheric pressure is the most objective weather factor because regardless of if outdoors or indoors it affects all objects in the same way. The majority of previous studies have used the average daily values of atmospheric pressure in a bioclimatic analysis and have found no correlation with blood pressure changes. The main objective of our research was to assess the relationship between atmospheric pressure recorded with a frequency of 1 measurement per minute and the results of 24-h blood pressure monitoring in patients with treated hypertension in different seasons in the moderate climate of the City of Łódź (Poland). The study group consisted of 1662 patients, divided into 2 equal groups (due to a lower and higher average value of atmospheric pressure). Comparisons between blood pressure values in the 2 groups were performed using the Mann-Whitney U test. We observed a significant difference in blood pressure recorded during the lower and higher range of atmospheric pressure: on the days of the spring months systolic (p = 0.043) and diastolic (p = 0.005) blood pressure, and at nights of the winter months systolic blood pressure (p = 0.013). A significant inverse relationship between atmospheric pressure and blood pressure during the spring days and, only for systolic blood pressure, during winter nights was observed. Int J Occup Med Environ Health 2016;29(5):783-792. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Hara, Azusa; Tanaka, Kazushi; Ohkubo, Takayoshi; Kondo, Takeo; Kikuya, Masahiro; Metoki, Hirohito; Hashimoto, Takanao; Satoh, Michihiro; Inoue, Ryusuke; Asayama, Kei; Obara, Taku; Hirose, Takuo; Izumi, Shin-Ichi; Satoh, Hiroshi; Imai, Yutaka
2012-01-01
The usefulness of ambulatory, home, and casual/clinic blood pressure measurements to predict subclinical cerebrovascular diseases (silent cerebrovascular lesions and carotid atherosclerosis) was compared in a general population. Data on ambulatory, home, and casual/clinic blood pressures and brain MRI to detect silent cerebrovascular lesions were obtained in 1007 subjects aged ≥55 years in a general population of Ohasama, Japan. Of the 1007 subjects, 583 underwent evaluation of the extent of carotid atherosclerosis. Twenty-four-hour, daytime, and nighttime ambulatory and home blood pressure levels were closely associated with the risk of silent cerebrovascular lesions and carotid atherosclerosis (all P<0.05). When home and one of the ambulatory blood pressure values were simultaneously included in the same regression model, each of the ambulatory blood pressure values remained a significant predictor of silent cerebrovascular lesions, whereas home blood pressure lost its predictive value. Of the ambulatory blood pressure values, nighttime blood pressure was the strongest predictor of silent cerebrovascular lesions. The home blood pressure value was more closely associated with the risk of carotid atherosclerosis than any of the ambulatory blood pressure values when home and one of the ambulatory blood pressure values were simultaneously included in the same regression model. The casual/clinic blood pressure value had no significant association with the risk of subclinical cerebrovascular diseases. Although the clinical indications for ambulatory blood pressure monitoring and home blood pressure measurements may overlap, the clinical significance of each method for predicting target organ damage may differ for different target organs.
Li, Yu-Ying; Mazarakis, Thodoris; Shen, Yu-Chih; Yang, Miao-Chun; Chang, En-Ting; Wang, Hsiu-Mei
2016-08-01
Background Obstructive sleep apnea involves repeated nocturnal desaturation and sleep fragmentation that leads to poor sleep quality, anxiety, and depression. This study aimed to investigate short- and long-term improvements in the anxiety and depression of patients with different obstructive sleep apnea treatments. Methods This is a prospective, non-randomized hospital-based study evaluated 55 patients (46 male, 9 female) with obstructive sleep apnea. The patients were divided into three groups based on different treatment: uvulopalatopharyngoplasty group, continuous positive airway pressure group, and no treatment group (by their own decision). They completed the Beck Depression Inventory II, Beck Anxiety Inventory, and Pittsburgh Sleep Quality Index before treatment and at one and six months after treatment. Results Compared to the no treatment group, the surgery and continuous positive airway pressure groups had higher body mass index, AHI, and Epworth sleepiness scale, but no difference in Pittsburgh Sleep Quality Index, Chinese Health Questionnaire-12, Beck Depression Inventory II, and Beck Anxiety Inventory. The continuous positive airway pressure and surgery groups still had no improvements in Pittsburgh Sleep Quality Index, Chinese Health Questionnaire-12, Beck Depression Inventory II, and Beck Anxiety Inventory scores one month after treatment. At six months after treatment, the continuous positive airway pressure group had significantly decreased Pittsburgh Sleep Quality Index, Chinese Health Questionnaire-12, Beck Depression Inventory II, and Beck Anxiety Inventory, whereas the surgery group had significant difference in Beck Anxiety Inventory only and the no treatment group still had no significant difference in any of the parameters. Conclusions Continuous positive airway pressure can improve the sleep quality, quality of life, depression, and anxiety of obstructive sleep apnea patients after six months of treatment. However, surgery can significantly improve anxiety only in the same period.
Weinberg, Ido; Gona, Philimon; O’Donnell, Christopher J.; Jaff, Michael R.; Murabito, Joanne M.
2014-01-01
Background An increased inter-arm systolic blood pressure difference is an easily determined physical examination finding. The relationship between inter-arm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of inter-arm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between inter-arm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. Methods An increased inter-arm systolic blood pressure difference was defined as ≥10mmHg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of inter-arm systolic blood pressure difference on incident cardiovascular disease. Results We examined 3,390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute inter-arm systolic blood pressure difference was 4.6 mmHg (range 0 to 78). Increased inter-arm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event including 83 (26.2%) participants with inter-arm systolic blood pressure difference ≥10 mmHg. Compared to those with normal inter-arm systolic blood pressure difference, participants with an elevated inter-arm systolic blood pressure difference were older (63.0 years vs. 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs. 7.5%,), higher systolic blood pressure (136.3 mmHg vs. 129.3 mmHg), and a higher total cholesterol level (212.1 mg/dL vs. 206.5 mg/dL). Inter-arm systolic blood pressure difference was associated with a significantly increased hazard of incident cardiovascular events in the multivariable adjusted model (hazard ratio 1.38, 95% CI, 1.09 to 1.75). For each 1-standard deviation unit increase in absolute interarm systolic blood pressure difference, the hazard ratio for incident cardiovascular events was 1.07 (CI, 1.00 to 1.14) in the fully-adjusted model. There was no such association with mortality (hazard ratio 1.02, 95% CI 0.76 to 1.38). Conclusions In this community-based cohort, an inter-arm systolic blood pressure difference is common and associated with a significant increased risk for future cardiovascular events, even when the absolute difference in arm systolic blood pressure is modest. These findings support research to expand clinical use of this simple measurement. PMID:24287007
Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.
Hirai, M; Niimi, K; Iwata, H; Sugimoto, I; Ishibashi, H; Ota, T; Nakamura, H
2010-08-01
To compare the interface pressure during rest and exercise among various kinds of arm sleeves. The interface pressure underneath nine different arm sleeves was measured during 10 maximal opening and closing movements of fingers using a pressure transducer (Air Pack Type Analyser) in 16 healthy volunteers. Furthermore, in order to evaluate the characteristics of each arm sleeve, the extensibility, stiffness and thickness were determined in vitro by several apparatuses. There was a significant correlation between stiffness and extensibility. The stiffness was significantly correlated with the pressure difference between muscle contraction and relaxation during exercise. The higher the value of stiffness, the greater the pressure amplitude during exercise. Short-stretch arm sleeves characterized with a high level stiffness, including thick round- and flat-knitted arm sleeves, are more beneficial for the augmentation of muscle pumping than long-stretch arm sleeves, in the same way as short-stretch bandages or stockings applied to the leg.
Yan, W L; Li, X S; Wang, Q; Huang, Y D; Zhang, W G; Zhai, X H; Wang, C C; Lee, J H
2015-01-01
To investigate whether the levels of blood pressure and fasting glucose differ among Chinese children of three different ethnicities (i.e., Uyghurs, Kazakhs, and Hans) and whether the differences are explained by childhood obesity. A school-based cross-sectional study was conducted in a large three ethnic pediatric population (n = 6633), whose ages ranged from 7 to 18 years. Anthropometrics and blood pressure were measured using standard protocols. Fasting glucose was measured in a subset of children (n = 2295) who were randomly selected based on ethnicity and age. The age-sex stratified Chinese national cut-offs were used to define obesity and high blood pressure (HBP). The prevalence of HBP, impaired fasting glucose (IFG), mean levels of blood pressure, and glucose were compared among three ethnic groups. 2142 Uyghurs, 2078 Han, and 1997 Kazakhs were analyzed. After adjusting for age and body mass index (BMI), the mean blood pressure for Uyghurs was on average, 2-4 mm Hg lower than those for Hans and Kazakhs. Kazakhs had the lowest mean fasting glucose compared with Hans and Uyghurs (4.5 vs. 5.0 vs. 4.8 mmol/L, respectively). The differences in blood pressure and fasting glucose persisted even after adjusting for age and BMI, and the differences among ethnic groups in blood pressure levels and fasting glucose levels were observed as early as 7-9 years of age. The prevalence of HBP and IFG differed significantly among Uyghurs, Hans, and Kazakhs, and the ethnic differences observed in childhood were consistent with those observed in adults from the same region. While childhood obesity is a significant risk factor for hypertension and elevated glucose, the differences among ethnic groups were not explained by obesity alone.
Stimulated pressure profile at rest: a noninvasive method for assessing urethral sphincter function.
Meyer, S; Kuntzer, T; De Grandi, P; Bachelard, O; Schreyer, A
1998-10-01
To validate a method for assessing urethral sphincter muscle function by recording rises in intraurethral pressure during repetitive pudendal nerve stimulations. A supine urethral pressure profile at rest was performed on 12 stress-continent and 28 stress-incontinent patients during repetitive pudendal nerve stimulations applied near the ischial spine, and the intraurethral pressure increases were calculated for each third of the urethral functional length. No significant difference in intraurethral pressure increases was seen between continent and stress-incontinent women. On the various regression curves, the intraurethral pressure increases showed a significant correlation with maximal urethral closure pressure values at rest and at stress (r = 0.36 to 0.54) and with the patient's age (r = 0.46), but not with pudendal nerve conduction times to the urethral sphincter on either side (r = 0.14 and 0.19). This method (1) measures intraurethral pressure increases that correlate well with the anatomic location of the urethral sphincter muscle, (2) shows there is no significant difference between them in continent and stress-incontinent patients, except in patients with a low-pressure urethra, and (3) demonstrates that they correlate well with the maximal urethral closure pressure and the patient's age, but not with pudendal motor latencies to the urethral sphincter. This method gives us a mapping of the urethral sphincter activity, explaining why some patients with a low-pressure urethra have less urinary loss than others with the same urethral closure pressure.
Barakat-Haddad, Caroline
2013-01-01
This study examined the prevalence of high blood pressure, heart disease, and medical diagnoses in relation to blood disorders, among 6,329 adolescent students (age 15 to 18 years) who reside in the United Arab Emirates (UAE). Findings indicated that the overall prevalence of high blood pressure and heart disease was 1.8% and 1.3%, respectively. Overall, the prevalence for thalassemia, sickle-cell anemia, and iron-deficiency anemia was 0.9%, 1.6%, and 5%, respectively. Bivariate analysis revealed statistically significant differences in the prevalence of high blood pressure among the local and expatriate adolescent population in the Emirate of Sharjah. Similarly, statistically significant differences in the prevalence of iron-deficiency anemia were observed among the local and expatriate population in Abu Dhabi city, the western region of Abu Dhabi, and Al-Ain. Multivariate analysis revealed the following significant predictors of high blood pressure: residing in proximity to industry, nonconventional substance abuse, and age when smoking or exposure to smoking began. Ethnicity was a significant predictor of heart disease, thalassemia, sickle-cell anemia, and iron-deficiency anemia. In addition, predictors of thalassemia included gender (female) and participating in physical activity. Participants diagnosed with sickle-cell anemia and iron-deficiency anemia were more likely to experience different physical activities. PMID:23606864
Prediction of wound healing after minor amputations of the diabetic foot.
Caruana, Luana; Formosa, Cynthia; Cassar, Kevin
2015-08-01
To identify any significant differences in physiological test results between healing and non healing amputation sites. A single center prospective non-experimental study design was conducted on fifty subjects living with type 2 diabetes and requiring a forefoot or toe amputation. Subjects underwent non-invasive physiological testing preoperatively. These included assessment of pedal pulses, preoperative arterial spectral waveforms at the ankle, absolute toe pressures, toe-brachial pressure index and ankle-brachial pressure index. After 6 weeks, patients were examined to assess whether the amputation site was completely healed, was healing, had developed complications, or did not heal. There was no significant difference in ABPI between the healed/healing and the non-healing groups. Mean TBI (p=0.031) and toe pressure readings (p=0.014) were significantly higher in the healed/healing group compared to the non healing group. A significant difference was also found in ankle spectral waveforms between the two groups (p=0.028). TBIs, toe pressures and spectral waveforms at the ankle are better predictors of likelihood of healing and non-healing after minor amputation than ABPIs. ABPI alone is a poor indicator of the likelihood of healing of minor amputations and should not be relied on to determine need for revascularization procedures before minor amputation. Copyright © 2015 Elsevier Inc. All rights reserved.
Szúcs, G; Tóth, I; Bráth, E; Gyáni, K; Miko, I
2001-08-01
We have good results with telescopic anastomosis technique in partial oesophagectomies and gastrectomies. As we could not find data about the healing process of telescopic anastomoses so we started experimenting. Inside pressure tolerance was examined immediately after performing anastomoses by measuring the bursting pressure using the organs of pigs slaughtered in the meat industry. Both oesophago-gastrostomies and oesophago-jejunostomies were performed with telescopic, single layer interrupted, single layer continuous, double layer interrupted and double layer continuous-interrupted technique, 9 of each anastomosis. A series of oesophago-jejunostomies were performed with EEA stapler. 99 anastomoses of 11 types were investigated. We found, that the inner pressure tolerance of telescopic oesophago-gastrostomy is better than any other single layer type variant. On the other hand the double layer type variants have much better pressure tolerance than the telescopic and other two type single layer anastomoses. The difference is statistically significant. In oesophago-jejunostomies the pressure tolerance of telescopic anastomosis is better than of the single layer interrupted type but the difference between the telescopic and single layer continuous type anastomoses is not significant. The pressure tolerance of double layer anastomosis is higher than the telescopic one but the difference is significant only in the continuous-interrupted type. The inner pressure tolerance of telescopic and EEA stapler anastomoses are equal. The investigation of additional features in anastomosis healing is in progress.
The significance of visitors' pressure for soil status in an urban park in Tel-Aviv
NASA Astrophysics Data System (ADS)
Zhevelev, Helena; Sarah, Pariente; Oz, Atar
2010-05-01
A park is one of the most important elements of sustainable development and optimization of the urban environment. The equilibrium within the complex of natural and anthropogenic factors defines the status of a park's ecosystem. The seasonal dynamics and spatial variations of soil properties in areas under differing levels of visitors' pressure were studied in a park in Tel-Aviv. Soil was sampled twice a year, in wet (March) and dry (July) seasons, from three types of areas, subjected to differing levels of visitors' pressure: high, low and none (control). In each type of area samples were taken from two depths (0-2 cm and 5-10 cm), at 14-39 points. In total, 268 soil samples were taken. Before the soil sampling, penetration depth was determined at each point. In addition, the numbers of barbecue fires in each of the three areas were counted. Gravimetric soil moisture, organic matter, pH, electrical conductivity, and soluble ions were measured in 1:1 water extraction. Penetration depth and electrical conductivity, and organic matter, sodium, potassium and chlorite contents differed under differing levels of visitors' pressure, whereas soil moisture, pH and calcium content exhibited only minor differences. Soil moisture, electrical conductivity, and magnesium and chlorite contents exhibited strong seasonal changes, whereas the organic matter, potassium and pH levels were unaffected by seasonal dynamics. Calcium, organic matter, magnesium and chlorite contents, and electrical conductivity were significantly affected by the depth of soil sampling, whereas pH was not so affected. The seasonal changes in soil properties in the area subjected to high visitors' pressure were higher than in the one under low visitors' pressure. In most cases, visitors' pressure led to increases in variance and coefficient of variation. Different soil properties were differently affected by visitors' pressure, seasonal dynamics and soil depth. The surface of the soil was more sensitive to both seasonal dynamics and visitors' pressure, than the deeper layer. Visitors' pressure increased seasonal changes in the studied soil properties, and also increased the spatial heterogeneity of the soil. The differences in organic matter, electrical conductivity and soluble ions among the areas under differing visitors' pressure are attributed to anthropogenic additions, which accompanied the recreational activities in the urban parks: remnants of barbecue fires and meals, and excreta of urban animals. Addition of urban dust, enriched in CaCO3, minimized the effect of visitors' pressure on soil calcium content. All the above anthropogenic additions enhance the differentiation in soil layers. The notable effect of visitors' pressure on variations in soil properties highlighted its high significance for urban parks.
Safari, Mohammad Reza; Tafti, Nahid; Aminian, Gholamreza
2015-01-01
The objectives of the current study were to compare intra-socket pressure differences between comfortable and uncomfortable socket conditions, and the usefulness of subject perception of satisfaction, activity limitations, and socket comfort in distinguishing between these two socket conditions. Five unilateral trans-tibial amputees took part in the study. They answered the Socket Comfort Score (SCS) and Trinity Amputation and Prosthetic Experience Scale (TAPES) questionnaires before the interface pressure (in standing and walking) was measured for the uncomfortable socket condition at five regions of the residual limb. Participants were then provided with a comfortable socket and wore it for two weeks. Participants who were satisfied with the socket fit after two weeks repeated the SCS and TAPES questionnaires and interface pressure measurements. The differences between the test results of the two conditions were not statistically significant, except for the interface pressure at the popliteal region during the early stance phase, TAPES socket fit subscale, and the SCS. Due to large variability of the data and the lack of statistical significance, no firm conclusion can be made on the possible relationship between the interface pressure values and the patient-reported outcomes of the two socket conditions. A larger sample size and longer acclimation period are required to locate significant differences.
Fonseca-Reyes, Salvador; Forsyth-MacQuarrie, Avril M; García de Alba-García, Javier Eduardo
2012-08-01
When blood pressure (BP) is taken for the first time, it should be measured in both arms; follow-up measurements should be taken in the arm with the highest BP. However, in clinical practice, this recommendation is rarely followed. Identify the degree of differences in BP between the right and the left arm in individuals with normal and high BP. We measured BP in 111 hypertensive and 80 normotensive patients in both arms at the same time using identical Omron HEM 725 CIC automatic sphygmomanometers. The devices were then switched to the other arm and another set of readings was taken. The absolute and relative difference in BP between arms was calculated from the average of these two readings. We categorized differences as at least 5, at least 10, and at least 20 mmHg for systolic blood pressure/diastolic blood pressure (SBP/DBP). The BP was higher in the right arm, with no statistical significance. The relative differences were also not significant: SBP 1.1±7.1 and DBP 0.21±5.0. However, the absolute differences were significant at an individual level, with a systolic difference of 5.4±4.8 mmHg and a diastolic difference of 3.9 ±3.2 mmHg. The percentages of absolute SBP/DBP differences more than 5 mmHg (21.4%/20.4%) and more than 10 mmHg (15.7%/4.7%) were considerable. The range of arm differences was clinically significant; in hypertensives, the SBP/DBP was -13.2 to +15/-9.2 to +9.6 mmHg and in nonhypertensives it was -12.9 to +15.6/-9.7 to +10.1 mmHg. Although on average there was no clinically significant relative difference between arms, absolute differences at an individual level were often clinically significant. Failure to determine interarm BP differences will lead to erroneous clinical decisions.
Yung, Emmanuel; Wong, Michael; Williams, Haddie; Mache, Kyle
2014-08-01
Randomized clinical trial. Objectives To compare the blood pressure (BP) and heart rate (HR) response of healthy volunteers to posteriorly directed (anterior-to-posterior [AP]) pressure applied to the cervical spine versus placebo. Manual therapists employ cervical spine AP mobilizations for various cervical-shoulder pain conditions. However, there is a paucity of literature describing the procedure, cardiovascular response, and safety profile. Thirty-nine (25 female) healthy participants (mean ± SD age, 24.7 ± 1.9 years) were randomly assigned to 1 of 2 groups. Group 1 received a placebo, consisting of light touch applied to the right C6 costal process. Group 2 received AP pressure at the same location. Blood pressure and HR were measured prior to, during, and after the application of AP pressure. One-way analysis of variance and paired-difference statistics were used for data analysis. There was no statistically significant difference between groups for mean systolic BP, mean diastolic BP, and mean HR (P >.05) for all time points. Within-group comparisons indicated statistically significant differences between baseline and post-AP pressure HR (-2.8 bpm; 95% confidence interval: -4.6, -1.1) and between baseline and post-AP pressure systolic BP (-2.4 mmHg; 95% confidence interval: -3.7, -1.0) in the AP group, and between baseline and postplacebo systolic BP (-2.6 mmHg; 95% confidence interval: -4.2, -1.0) in the placebo group. No participants reported any adverse reactions or side effects within 24 hours of testing. AP pressure caused a statistically significant physiologic response that resulted in a minor drop in HR (without causing asystole or vasodepression) after the procedure, whereas this cardiovascular change did not occur for those in the placebo group. Within both groups, there was a small but statistically significant reduction in systolic BP following the procedure.
Shishido, Keiichi; Peng, Qiyu; Jones, Ruth; Omata, Sadao; Constantinou, Christos E
2008-05-01
We characterized the vaginal pressure profile as a representation of closure forces along the length and circumference of the vaginal wall. Vaginal pressure profile data were used to test the hypothesis that the strength of pelvic floor muscle contractions differs significantly between continent women and women with stress urinary incontinence. Vaginal pressure profile recordings were made in 23 continent subjects and in 10 patients with stress urinary incontinence. The recordings characterized closure forces along the entire length of the vagina and identified differences among the anterior, posterior, left and right sides of the vaginal wall. Using a novel, directionally sensitive vaginal probe we made vaginal pressure profile measurements with the women at rest and during pelvic floor muscle contraction while supine. The nature of the vaginal pressure profile was characterized in terms of force distribution in the anterior and posterior vaginal walls, which was significantly greater than that on the left and right sides. The continent group had significant greater maximum pressure than the stress urinary incontinence group on the posterior side at rest (mean +/- SE 3.4 +/- 0.3 vs 2.01 +/- 0.36 N/cm(2)) and during pelvic floor muscle contraction (4.18 +/- 0.26 vs 2.25 +/- 0.41 N/cm(2)). The activity pressure difference between the posterior and anterior vaginal walls in the continent group was significantly increased when the pelvic floor muscles contracted vs that at rest (3.29 +/- 0.21 vs 2.45 +/- 0.26 N/cm(2)). However, the change observed in the stress urinary incontinence group was not significant (1.85 +/- 0.38 vs 1.35 +/- 0.27 N/cm(2)). The results demonstrate that the voluntary pelvic floor muscles impose significant closure forces along the vaginal wall of continent women but not in women with stress urinary incontinence. The implication of these findings is that extrinsic urethral closure pressure is insufficiently augmented by pelvic floor muscle contraction in women with stress urinary incontinence.
Complexity of intracranial pressure correlates with outcome after traumatic brain injury
Lu, Cheng-Wei; Czosnyka, Marek; Shieh, Jiann-Shing; Smielewska, Anna; Pickard, John D.
2012-01-01
This study applied multiscale entropy analysis to investigate the correlation between the complexity of intracranial pressure waveform and outcome after traumatic brain injury. Intracranial pressure and arterial blood pressure waveforms were low-pass filtered to remove the respiratory and pulse components and then processed using a multiscale entropy algorithm to produce a complexity index. We identified significant differences across groups classified by the Glasgow Outcome Scale in intracranial pressure, pressure-reactivity index and complexity index of intracranial pressure (P < 0.0001; P = 0.001; P < 0.0001, respectively). Outcome was dichotomized as survival/death and also as favourable/unfavourable. The complexity index of intracranial pressure achieved the strongest statistical significance (F = 28.7; P < 0.0001 and F = 17.21; P < 0.0001, respectively) and was identified as a significant independent predictor of mortality and favourable outcome in a multivariable logistic regression model (P < 0.0001). The results of this study suggest that complexity of intracranial pressure assessed by multiscale entropy was significantly associated with outcome in patients with brain injury. PMID:22734128
Clonidine versus nitroglycerin infusion in laparoscopic cholecystectomy.
Mishra, Manjaree; Mishra, Shashi Prakash; Mathur, Sharad Kumar
2014-01-01
Laparoscopic surgery offers the advantages of minimally invasive surgery; however, pneumoperitoneum and the patient's position induce pathophysiological changes that may complicate anesthetic management. We studied the effect of clonidine and nitroglycerin on heart rate and blood pressure, if any, in association with these drugs or the procedure, as well as the effect of these drugs, if any, on end-tidal carbon dioxide pressure and intraocular pressure. Sixty patients (minimum age of 20 years and maximum age of 65 years, American Society of Anesthesiologists class I or II) undergoing laparoscopic cholecystectomy were randomized into 3 groups and given an infusion of clonidine (group I), nitroglycerin (group II), or normal saline solution (group III) after induction and before creation of pneumoperitoneum. We observed and recorded the following parameters: heart rate, mean arterial blood pressure, end-tidal carbon dioxide pressure, and intraocular pressure. The mean and standard deviation of the parameters studied during the observation period were calculated for the 3 treatment groups and compared by use of analysis of variance tests. Intragroup comparison was performed with the paired t test. The critical value of P, indicating the probability of a significant difference, was taken as < .05 for comparisons. Statistically significant differences in heart rate were observed among the various groups, whereas comparisons of mean arterial pressure, intraocular pressure, and end-tidal carbon dioxide pressure showed statistically significant differences only between groups I and III and between groups II and III. We found clonidine to be more effective than nitroglycerin at preventing changes in hemodynamic parameters and intraocular pressure induced by carbon dioxide insufflation during laparoscopic cholecystectomy. It was also found not to cause hypotension severe enough to stop the infusion and warrant treatment.
Clonidine Versus Nitroglycerin Infusion in Laparoscopic Cholecystectomy
Mishra, Manjaree; Mishra, Shashi Prakash
2014-01-01
Background and Objectives: Laparoscopic surgery offers the advantages of minimally invasive surgery; however, pneumoperitoneum and the patient's position induce pathophysiological changes that may complicate anesthetic management. We studied the effect of clonidine and nitroglycerin on heart rate and blood pressure, if any, in association with these drugs or the procedure, as well as the effect of these drugs, if any, on end-tidal carbon dioxide pressure and intraocular pressure. Methods: Sixty patients (minimum age of 20 years and maximum age of 65 years, American Society of Anesthesiologists class I or II) undergoing laparoscopic cholecystectomy were randomized into 3 groups and given an infusion of clonidine (group I), nitroglycerin (group II), or normal saline solution (group III) after induction and before creation of pneumoperitoneum. We observed and recorded the following parameters: heart rate, mean arterial blood pressure, end-tidal carbon dioxide pressure, and intraocular pressure. The mean and standard deviation of the parameters studied during the observation period were calculated for the 3 treatment groups and compared by use of analysis of variance tests. Intragroup comparison was performed with the paired t test. The critical value of P, indicating the probability of a significant difference, was taken as < .05 for comparisons. Results: Statistically significant differences in heart rate were observed among the various groups, whereas comparisons of mean arterial pressure, intraocular pressure, and end-tidal carbon dioxide pressure showed statistically significant differences only between groups I and III and between groups II and III. Conclusion: We found clonidine to be more effective than nitroglycerin at preventing changes in hemodynamic parameters and intraocular pressure induced by carbon dioxide insufflation during laparoscopic cholecystectomy. It was also found not to cause hypotension severe enough to stop the infusion and warrant treatment. PMID:25392635
Improving the side-to-side stapled anastomosis: comparison of staplers for robust crotch formation.
Kimura, Masahiro; Kuwabara, Yoshiyuki; Taniwaki, Satoshi; Mitsui, Akira; Shibata, Yasuyuki; Ueno, Shuhei
2018-01-01
Few studies have investigated the burst pressure of side-to-side anastomoses comparing different stapling devices that are commercially available. We conducted side-to-side anastomoses with a variety of staplers and compared burst pressure in the crotch of the anastomoses. Nagoya City East Medical Center. We conducted side-to-side anastomoses with 9 staplers with different shapes and forms. Fresh pig small intestines were used. A side-to-side anastomosis was performed between 2 intestine specimens using a linear stapler. The burst pressure of the anastomosis was recorded. In total, 45 staplers were used for this experiment. The site of leakage in all cases was the crotch. Regarding the influence of the number of staple rows, the burst pressure in 3-row staplers was significantly higher than in 2-row staplers. With regard to the relationship between staple height and burst pressure, staples with a height slightly shorter than the intestinal thickness showed the highest burst pressure. In a comparison of staplers with uniform staple heights and stamplers with staples of 3 different heights, the latter had significantly lower burst pressures. Neoveil significantly increased the burst pressure in the crotch and contributed to the highest burst pressure of all the staplers used in this experiment. In this experiment, we defined the important factors that influence burst pressure at the crotch of a stapled, side-to-side anastomosis. These factors include the number of staple rows, the height of the staple compared with the thickness of the tissue, uniformity of staple height, and reinforcement of the staple line. In any surgical case requiring intestinal anastomosis, selection of a stapler is a critical step. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Sleep Related Changes in Blood Pressure in Hypocretin-Deficient Narcoleptic Mice
Bastianini, Stefano; Silvani, Alessandro; Berteotti, Chiara; Elghozi, Jean-Luc; Franzini, Carlo; Lenzi, Pierluigi; Lo, Martire Viviana; Zoccoli, Giovanna
2011-01-01
Study Objectives: Although blood pressure during sleep and the difference in blood pressure between sleep and wakefulness carry prognostic information, little is known on their central neural mechanisms. Hypothalamic neurons releasing hypocretin (orexin) peptides control wake-sleep behavior and autonomic functions and are lost in narcolepsy-cataplexy. We investigated whether chronic lack of hypocretin signaling alters blood pressure during sleep. Design: Comparison of blood pressure as a function of the wake-sleep behavior between 2 different hypocretin-deficient mouse models and control mice with the same genetic background. Setting: N/A. Subjects: Hypocretin-ataxin3 transgenic mice with genetic ablation of hypocretin neurons (TG, n = 12); hypocretin gene knock-out mice (KO, n = 8); congenic wild-type controls (WT, n = 10). Interventions: Instrumentation with electrodes for sleep recordings and a telemetric blood pressure transducer. Measurements and Results: Blood pressure was significantly higher in either TG or KO than in WT during non–rapid eye movement sleep (NREMS; 4 ± 2 and 7 ± 2 mm Hg, respectively) and rapid eye movement sleep (REMS; 11 ± 2 and 12 ± 3 mm Hg, respectively), whereas it did not differ significantly between groups during wakefulness. Accordingly, the decrease in blood pressure between either NREMS or REMS and wakefulness was significantly blunted in TG and KO with respect to WT. Conclusions: Chronic lack of hypocretin signaling may entail consequences on blood pressure that are potentially adverse and that vary widely among wake-sleep states. Citation: Bastianini S; Silvani A; Berteotti C; Elghozi JL; Franzini C; Lenzi P; Lo Martire V; Zoccoli G. Sleep related changes in blood pressure in hypocretin-deficient narcoleptic mice. SLEEP 2011;34(2):213-218. PMID:21286242
Wongsritrang, Krongthong; Fueangkamloon, Sumet
2013-09-01
To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.
1990-06-01
10 minutes after injection. No significant differences detected between the groups. 18 0 Table 7. Systolic Blood Pressure Group Atracurium 0.40 mg/kg...Table 8. Diastolic Blood Pressure Group Atracurium 0.40 mg/kg + Vecuronium 0.28 mg/kg Vecuronium 0.10 mg/kg (n=20) (n=20) Baseline(a) 72 + 2.4 72...significant differences detected between the groups. 20 0 Table 9. Mean Blood Pressure Group Atracurium 0.40 mg/kg + Vecuronium 0.28 mg/kg Vecuronium 0.10
Arterial Pressure Gradients during Upright Posture and 30 deg Head Down Tilt
NASA Technical Reports Server (NTRS)
Sanchez, E. R; William, J. M.; Ueno, T.; Ballard, R. E.; Hargens, A. R.; Holton, Emily M. (Technical Monitor)
1997-01-01
Gravity alters local blood pressure within the body so that arterial pressures in the head and foot are lower and higher, respectively, than that at heart level. Furthermore, vascular responses to local alterations of arterial pressure are probably important to maintain orthostatic tolerance upon return to the Earth after space flight. However, it has been difficult to evaluate the body's arterial pressure gradient due to the lack of noninvasive technology. This study was therefore designed to investigate whether finger arterial pressure (FAP), measured noninvasively, follows a normal hydrostatic pressure gradient above and below heart level during upright posture and 30 deg head down tilt (HDT). Seven healthy subjects gave informed consent and were 19 to 52 years old with a height range of 158 to 181 cm. A Finapres device measured arterial pressure at different levels of the body by moving the hand from 36 cm below heart level (BH) to 72 cm above heart level (AH) in upright posture and from 36 cm BH to 48 cm AH during HDT in increments of 12 cm. Mean FAP creased by 85 mmHg transitioning from BH to AH in upright posture, and the pressure gradient calculated from hydrostatic pressure difference (rho(gh)) was 84 mmHg. In HDT, mean FAP decreased by 65 mmHg from BH to AH, and the calculated pressure gradient was also 65 mmHg. There was no significant difference between the measured FAP gradient and the calculated pressure gradient, although a significant (p = 0.023) offset was seen for absolute arterial pressure in upright posture. These results indicate that arterial pressure at various levels can be obtained from the blood pressure at heart level by calculating rho(gh) + an offset. The offset equals the difference between heart level and the site of measurement. In summary, we conclude that local blood pressure gradients can be measured by noninvasive studies of FAP.
Variability of Tidal Volume in Patient-Triggered Mechanical Ventilation in ARDS.
Perinel-Ragey, Sophie; Baboi, Loredana; Guérin, Claude
2017-11-01
Limiting tidal volume (V T ) in patients with ARDS may not be achieved once patient-triggered breaths occur. Furthermore, ICU ventilators offer numerous patient-triggered modes that work differently across brands. We systematically investigated, using a bench model, the effect of patient-triggered modes on the size and variability of V T at different breathing frequencies (f), patient effort, and ARDS severity. We used a V500 Infinity ICU ventilator connected to an ASL 5000 lung model whose compliance was mimicking mild, moderate, and severe ARDS. Thirteen patient-triggered modes were tested, falling into 3 categories, namely volume control ventilation with mandatory minute ventilation; pressure control ventilation, including airway pressure release ventilation (APRV); and pressure support ventilation. Two levels of f and effort were tested for each ARDS severity in each mode. Median (first-third quartiles) V T was compared across modes using non-parametric tests. The probability of V T > 6 mL/kg ideal body weight was assessed by binomial regression and expressed as the odds ratio (OR) with 95% CI. V T variability was measured from the coefficient of variation. V T distribution over all f, effort, and ARDS categories significantly differed across modes ( P < .001, Kruskal-Wallis test). V T was significantly greater with pressure support (OR 420 mL, 95% CI 332-527 mL) than with any other mode except for variable pressure support level. Risk for V T to be > 6 mL/kg was significantly increased with spontaneous breaths patient-triggered by pressure support (OR 19.36, 95% CI 12.37-30.65) and significantly reduced in APRV (OR 0.44, 95% CI 0.26-0.72) and pressure support with guaranteed volume mode. The risk increased with increasing effort and decreasing f. Coefficient of variation of V T was greater for low f and volume control-mandatory minute ventilation and pressure control modes. APRV had the greatest within-mode variability. Risk of V T > 6 mL/kg was significantly reduced in APRV and pressure support with guaranteed volume mode. APRV had the highest variability. Pressure support with guaranteed volume could be tested in patients with ARDS. Copyright © 2017 by Daedalus Enterprises.
How securely is the testicular artery occluded in the spermatic cord by using a ligature?
Rijkenhuizen, A B M; Sommerauer, S; Fasching, M; Velde, K; Peham, C
2013-09-01
There are no studies on the ideal ligature technique for the spermatic cord. To compare the maximal resistance pressure in the testicular artery and the maximal tensile forces to produce failure of 2 different ligature techniques used for ligation of the equine spermatic cord. The capabilities of 2 types of ligatures, single knot loop and double knot loop, were assessed using a pressure-resistance test in testicular arteries and with an in vitro mechanical evaluation of the tensile strength by single cycle-to-failure testing. In the pressure-resistance test, the mean ± s.d. peak force at failure of the single knot loop was 354.4 ± 91.7 mmHg and for the double knot loop 303.2 ± 62.0 mmHg. There was no significant difference between the maximal load to failure of the single knot loop and double knot loop technique. The pressure needed for rupture was significantly higher (P = 0.001) than for leakage. The maximal tensile force at failure of the single knot loop was significantly higher than the double knot loop (P = 0.028). There was no significant difference in load elongation properties to failure between the single knot loop and double knot loop. Although no significant differences were obtained in the pressure-resistance test, the single knot loop sustained significantly greater load to failure than the double knot loop in single cycle-to-failure testing. Based on these findings, it would appear that the performance of the single knot loop should be superior to the double knot loop. Both ligature techniques are able to withstand the normal physiological intravascular pressure. The single knot loop has the greater breaking strength of the 2 ligatures tested and is less time consuming to perform and may therefore have advantages during equine castration. © 2012 EVJ Ltd.
Social support and health among elderly Kuwaitis.
Al-Kandari, Yagoub Y; Crews, Douglas E
2014-07-01
The aim of this study was to examine differences in several aspects of health between Kuwaiti men and women aged 60 years and over across three age categories (60-69, 70-79, 80+ years). The relationships between several social support variables, somatic symptoms and systolic and diastolic blood pressures were examined. A total of 1427 adult men (472) and women (955) aged 60 years and over representing all six governorates were selected. Data were collected during 2008-2009 by interview and completion of a questionnaire by participants in their own homes, after obtaining their informed consent. The Social Support Scale (SSS), Frequency of Contact Scale (FOC), Strength of Relations (SOR), Somatic Symptoms Inventory (SSI) and self-rated scales of general health were included. Systolic and diastolic blood pressures were measured. The data show that self-rated health and health in the last year differ significantly across age groups. Glycaemia differed significantly across the three age groups for the total sample. Systolic and diastolic blood pressure were higher in older respondents than younger ones, but no significant differences were observed between men and women. No significant differences in somatic symptoms were observed across the three age groups. Strength of relationship, frequency of contact, social support and children living with an elderly adult were all associated with fewer somatic symptoms, and all, except social support, were associated with lower systolic and diastolic blood pressure. Having children, the perception of social support, frequency of contact with, and strength of, relationships with kin are important modulators of somatic symptoms and blood pressure among elderly Kuwaitis.
2013-01-01
Background This study aimed to examine age-related, interindividual, and right/left differences in anterior-posterior foot pressure ratio in 764 preschool children (364 boys and 400 girls) aged 3.5-6.5 years. Methods Subjects maintained an upright standing posture for 10 seconds on the Footview Clinic, an instrument designed to calculate the anterior-posterior foot pressure ratio. The ratio of anterior foot pressure in each subject’s right and left feet was selected as a variable, and the mean of a 10 s measurement was used for analysis. Results The ratio of anterior foot pressure was significantly larger in the right foot than in the left foot. With regard to age, the ratio of anterior foot pressure was significantly larger in children aged over 4.5 years than in children aged 3.5 years. It was also larger in children aged 6 and 6.5 years than in children aged 4 years. Interindividual differences in variables were large, and coefficients of variance were highest in children aged 3.5 years and lowest in children aged 6.5 years. Conclusions In conclusion, anterior foot pressure increases with age in preschool children. Interindividual differences in anterior foot pressure are large and tend to decrease with age. Furthermore, the anterior foot pressure is slightly higher in the right foot than in the left foot. These results will be useful for various studies, such as examining relationships between the anterior-posterior foot pressure ratio and factors, such as untouched toes, physical fitness, and level of exercise. PMID:23601375
Delgado, Francisco José; Delgado, Jonathan; González-Crespo, José; Cava, Ramón; Ramírez, Rosario
2013-12-01
The effect of high-pressure treatment (400 or 600 MPa for 7 min) on microbiology, proteolysis, texture and sensory parameters was investigated in a mature raw goat milk cheese. At day 60 of analysis, Mesophilic aerobic, Enterobacteriaceae, lactic acid bacteria and Listeria spp. were inactivated after high-pressure treatment at 400 or 600 MPa. At day 90, mesophilic aerobic, lactic acid bacteria and Micrococacceae counts were significantly lower in high-pressure-treated cheeses than in control ones. In general, nitrogen fractions were significantly modified after high-pressure treatment on day 60 at 600 MPa compared with control cheeses, but this effect was not found in cheeses after 30 days of storage (day 90). On the other hand, high-pressure treatment caused a significant increase of some texture parameters. However, sensory analysis showed that neither trained panellists nor consumers found significant differences between control and high-pressure-treated cheeses.
Wang, Lin; Cull, Grant A; Fortune, Brad
2015-04-01
To test the hypothesis that blood flow autoregulation in the optic nerve head has less reserve to maintain normal blood flow in the face of blood pressure-induced ocular perfusion pressure decrease than a similar magnitude intraocular pressure-induced ocular perfusion pressure decrease. Twelve normal non-human primates were anesthetized by continuous intravenous infusion of pentobarbital. Optic nerve blood flow was monitored by laser speckle flowgraphy. In the first group of animals (n = 6), the experimental eye intraocular pressure was maintained at 10 mmHg using a saline reservoir connected to the anterior chamber. The blood pressure was gradually reduced by a slow injection of pentobarbital. In the second group (n = 6), the intraocular pressure was slowly increased from 10 mmHg to 50 mmHg by raising the reservoir. In both experimental groups, optic nerve head blood flow was measured continuously. The blood pressure and intraocular pressure were simultaneously recorded in all experiments. The optic nerve head blood flow showed significant difference between the two groups (p = 0.021, repeat measures analysis of variance). It declined significantly more in the blood pressure group compared to the intraocular pressure group when the ocular perfusion pressure was reduced to 35 mmHg (p < 0.045) and below. There was also a significant interaction between blood flow changes and the ocular perfusion pressure treatment (p = 0.004, adjusted Greenhouse & Geisser univariate test), indicating the gradually enlarged blood flow difference between the two groups was due to the ocular perfusion pressure decrease. The results show that optic nerve head blood flow is more susceptible to an ocular perfusion pressure decrease induced by lowering the blood pressure compared with that induced by increasing the intraocular pressure. This blood flow autoregulation capacity vulnerability to low blood pressure may provide experimental evidence related to the hemodynamic pathophysiology in glaucoma.
Uzeda, Marcelo José; Moura, Brenda; Louro, Rafael Seabra; da Silva, Licínio Esmeraldo; Calasans-Maia, Mônica Diuana
2014-05-01
The control of hypertensive patients' blood pressure and heart rate using vasoconstrictors during surgical procedures under anesthesia is still a major concern in everyday surgical practice. This clinical trial aimed to evaluate the variation of blood pressure and heart rate in nonhypertensive and controlled hypertensive voluntary subjects undergoing oral surgery under local anesthesia with lidocaine hydrochloride and epinephrine at 1:100,000 (Alphacaine; DFL, Brazil), performed in the Oral Surgery Department, Dentistry School, Fluminense Federal University. In total, 25 voluntary subjects were divided into 2 groups: nonhypertensive (n = 15) and controlled hypertensives (n = 10). Blood pressure and heart rate were measured at 4 different times: T0, in the waiting room; T1, after placement of the surgical drapes; T2, 10 minutes after anesthesia injection; and T3, at the end of the surgical procedure. A statistically significant difference (P < 0.05) between the groups was found at times T0 and T2 for the systolic pressure but only at time T0 for the diastolic pressure. The assessment of the heart rate of both groups showed a statistically significant difference (P < 0.05) at time T1. An analysis of the employed anesthetic volume indicated no statistically significant difference (P > 0.05) between the amount administered to nonhypertensive and hypertensive subjects. It was concluded that the local anesthetics studied could safely be used in controlled hypertensive and nonhypertensive patients in compliance with the maximum recommended doses.
Komasawa, Nobuyasu; Mihara, Ryosuke; Imagawa, Kentaro; Hattori, Kazuo; Minami, Toshiaki
2015-01-01
The present study compared changes in cuff pressure by head and neck position between high-volume low-pressure (HVLP) and taper-shaped (taper) cuffs in a prospective randomized clinical trial. Methods. Forty patients were intubated using tracheal tubes with either HVLP (n = 20; HVLP group) or taper-shaped (n = 20; Taper group) cuffs. Initial cuff pressure was adjusted to 15, 20, or 25 cmH2O in the neutral position. Cuff pressure was evaluated after changing the head and neck positions to flexion, extension, and rotation. Results. Cuff pressure significantly increased with flexion in both HVLP and Taper groups at all initial cuff pressures. It significantly increased with extension in the HVLP group, but not in the Taper group. Cuff pressure did not significantly differ with rotation in either group and was significantly smaller in the Taper group during flexion and extension than in the HVLP group, regardless of initial cuff pressure. Conclusion. Cuff pressure changes with head and neck flexion and extension were smaller in the Taper group than in the HVLP group. Our results highlight the potential for taper cuffs to prevent excessive cuff pressure increases with positional changes in the head and neck. This trial is registered with UMIN000016119. PMID:26509152
Adolfsson, Peter; Örnhagen, Hans; Eriksson, Bengt M.; Gautham, Raghavendhar; Jendle, Johan
2012-01-01
Background There is a need for reliable methods of glucose measurement in different environmental conditions. The objective of this in vitro study was to evaluate the performance of the Enlite® Sensor when connected to either the iPro™ Continuous Glucose Monitor recording device or the Guardian® REAL-Time transmitting device, in hypobaric and hyperbaric conditions. Methods Sixteen sensors connected to eight iPro devices and eight Guardian REAL-Time devices were immersed in three beakers containing separate glucose concentrations: 52, 88, and 207 mg/dl (2.9, 4.9, and 11.3 mmol/liter). Two different pressure tests were conducted: a hypobaric test, corresponding to maximum 18000 ft/5500 m height, and a hyperbaric test, corresponding to maximum 100 ft/30 m depth. The linearity of the sensor signals in the different conditions was evaluated. Results The sensors worked continuously, and the sensor signals were collected without interruption at all pressures tested. When comparing the input signals for glucose (ISIGs) and the different glucose concentrations during altered pressure, linearity (R2) of 0.98 was found. During the hypobaric test, significant differences (p < .005) were seen when comparing the ISIGs during varying pressure at two of the glucose concentrations (52 and 207 mg/dl), whereas no difference was seen at the 88 mg/dl glucose concentration. During the hyperbaric test, no differences were found. Conclusions The Enlite Sensors connected to either the iPro or the Guardian REAL-Time device provided values continuously. In hyperbaric conditions, no significant differences were seen during changes in ambient pressure; however, during hypobaric conditions, the ISIG was significantly different in the low and high glucose concentrations. PMID:23294783
Adolfsson, Peter; Ornhagen, Hans; Eriksson, Bengt M; Gautham, Raghavendhar; Jendle, Johan
2012-11-01
There is a need for reliable methods of glucose measurement in different environmental conditions. The objective of this in vitro study was to evaluate the performance of the Enlite® Sensor when connected to either the iPro™ Continuous Glucose Monitor recording device or the Guardian® REAL-Time transmitting device, in hypobaric and hyperbaric conditions. Sixteen sensors connected to eight iPro devices and eight Guardian REAL-Time devices were immersed in three beakers containing separate glucose concentrations: 52, 88, and 207 mg/dl (2.9, 4.9, and 11.3 mmol/liter). Two different pressure tests were conducted: a hypobaric test, corresponding to maximum 18000 ft/5500 m height, and a hyperbaric test, corresponding to maximum 100 ft/30 m depth. The linearity of the sensor signals in the different conditions was evaluated. The sensors worked continuously, and the sensor signals were collected without interruption at all pressures tested. When comparing the input signals for glucose (ISIGs) and the different glucose concentrations during altered pressure, linearity (R(2)) of 0.98 was found. During the hypobaric test, significant differences (p < .005) were seen when comparing the ISIGs during varying pressure at two of the glucose concentrations (52 and 207 mg/dl), whereas no difference was seen at the 88 mg/dl glucose concentration. During the hyperbaric test, no differences were found. The Enlite Sensors connected to either the iPro or the Guardian REAL-Time device provided values continuously. In hyperbaric conditions, no significant differences were seen during changes in ambient pressure; however, during hypobaric conditions, the ISIG was significantly different in the low and high glucose concentrations. © 2012 Diabetes Technology Society.
Impact of body weight on the relationship between alcohol intake and blood pressure.
Wakabayashi, Ichiro
2009-01-01
The reduction of habitual alcohol drinking is recommended for the prevention of hypertension. Daily or weekly alcohol consumption, which is used for evaluation of the effects of alcohol drinking on blood pressure, is usually not corrected by body weight. In this study, the influence of body weight on the relationship between alcohol intake and blood pressure was investigated. The subjects (27,005 healthy men at ages of 35-54 years) were divided into four groups by average daily ethanol intake [non-, light (<15 g per day), moderate (>or=15 and <30 g per day) and heavy (>or=30 g per day) drinkers]. The subjects were also divided into four quartile groups by body weight. Alcohol intake and the percentage of drinkers were not different in the four quartile groups of body weight. In the first and second quartiles of body weight, systolic and diastolic blood pressures were significantly higher in moderate and heavy drinkers than in non-drinkers, while systolic and diastolic blood pressures in the fourth quartile of body weight were significantly higher in heavy drinkers than in non-drinkers but were not significantly different in moderate drinkers and non-drinkers. The differences in systolic or diastolic blood pressure between non-drinkers and moderate drinkers and between non-drinkers and heavy drinkers became greater as body weight decreased. These results were not altered when age and smoking history were adjusted. The results suggest that body weight modifies the relationship between alcohol consumption and blood pressure and thus should be taken into account when effects of alcohol on blood pressure are considered.
Heffernan, Kevin S; Jae, Sae Young; Tomayko, Emily; Ishaque, Muhammad R; Fernhall, Bo; Wilund, Kenneth R
2009-05-01
Increased carotid intima-media thickness (IMT) with aging is a significant predictor of mortality. Older endurance trained (ET) individuals have lower carotid artery stiffness but similar carotid IMT when compared to sedentary (SED) age-matched peers. The purpose of this study was to examine the contribution of arterial wave reflections to carotid hemodynamics and IMT in older ET and SED with pre-hypertension. Subjects consisted of endurance-trained master athletes and age-matched sedentary controls (mean age 67 years). Carotid artery Beta-stiffness index and IMT was assessed with ultrasonography. Carotid pressure and augmented pressure from wave reflections (obtained from pulse contour analysis) was measured with applanation tonometry. Carotid systolic blood pressure (SBP) and IMT were not different between groups (P>0.05). Carotid stiffness was significantly lower in ET versus SED (7.3 +/- 0.8 versus 9.9 +/- 0.6, P<0.05). Augmented pressure was significantly greater in ET versus SED (17.7 +/- 1.6 versus 13.3 +/- 1.5 mmHg, P<0.05). When adjusting for differences in resting heart rate, there were no group differences in augmented pressure. In conclusion, older ET persons with pre-hypertension have reduced carotid artery stiffness, but similar carotid SBP and carotid IMT when compared to SED. The lack of change in carotid SBP and IMT in older ET may be related to the inability of chronic exercise training to reduce bradycardia-related augmented pressure from wave reflections with aging.
NASA Technical Reports Server (NTRS)
Vasilkov, Alexander; Joiner, Joanna; Spurr, Robert; Bhartia, Pawan K.; Levelt, Pieternel; Stephens, Graeme
2009-01-01
In this paper we examine differences between cloud pressures retrieved from the Ozone Monitoring Instrument (OMI) using the ultraviolet rotational Raman scattering (RRS) algorithm and those from the thermal infrared (IR) Aqua/MODIS. Several cloud data sets are currently being used in OMI trace gas retrieval algorithms including climatologies based on IR measurements and simultaneous cloud parameters derived from OMI. From a validation perspective, it is important to understand the OMI retrieved cloud parameters and how they differ with those derived from the IR. To this end, we perform radiative transfer calculations to simulate the effects of different geophysical conditions on the OMI RRS cloud pressure retrievals. We also quantify errors related to the use of the Mixed Lambert-Equivalent Reflectivity (MLER) concept as currently implemented of the OMI algorithms. Using properties from the Cloudsat radar and MODIS, we show that radiative transfer calculations support the following: (1) The MLER model is adequate for single-layer optically thick, geometrically thin clouds, but can produce significant errors in estimated cloud pressure for optically thin clouds. (2) In a two-layer cloud, the RRS algorithm may retrieve a cloud pressure that is either between the two cloud decks or even beneath the top of the lower cloud deck because of scattering between the cloud layers; the retrieved pressure depends upon the viewing geometry and the optical depth of the upper cloud deck. (3) Absorbing aerosol in and above a cloud can produce significant errors in the retrieved cloud pressure. (4) The retrieved RRS effective pressure for a deep convective cloud will be significantly higher than the physical cloud top pressure derived with thermal IR.
NASA Astrophysics Data System (ADS)
Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.
Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.
2016-01-01
Background For patients suffering from primary brain injury, monitoring intracranial pressure alone is not enough to reflect the dynamic intracranial condition. In our previous study, a segment of the pressure-volume curve can be expressed by the parabolic regression model with single indicator “a”. The aim of this study is to evaluate if the indicator “a” can reflect intracranial conditions. Methods Patients with traumatic brain injury, spontaneous intracranial hemorrhage, and/or hydrocephalus who had external ventricular drainage from January 2009 to February 2010 were included. The successive volume pressure response values were obtained by successive drainage of cerebral spinal fluid from intracranial pressure 20–25 mm Hg to 10 mm Hg. The relationship between withdrawn cerebral spinal fluid volume and intracranial pressure was analyzed by the parabolic regression model with single parameter “a”. Results The overall mean for indicator “a” was 0.422 ± 0.046. The mean of “a” in hydrocephalus was 0.173 ± 0.024 and in severe intracranial mass with slender ventricle, it was 0.663 ± 0.062. The two extreme intracranial conditions had a statistical significant difference (p<0.001). Conclusion The indicator “a” of a pressure-volume curve can reflect the dynamic intracranial condition and is comparable in different situations. A significantly larger indicator “a” with increased intracranial pressure is always observed in severe intracranial mass lesions with cerebral edema. A significantly smaller indicator “a” with increased intracranial pressure is observed in hydrocephalus. Brain computed tomography should be performed early if a rapid elevation of indicator “a” is detected, as it can reveal some ongoing intracranial pathology prior to clinical deterioration. Increased intracranial pressure was frequently observed in patients with intracranial pathology. The progression can be differentiated using the pattern of the volume pressure indicator. PMID:27723794
NASA Technical Reports Server (NTRS)
Firstenberg, M. S.; Vandervoort, P. M.; Greenberg, N. L.; Smedira, N. G.; McCarthy, P. M.; Garcia, M. J.; Thomas, J. D.
2000-01-01
OBJECTIVES: We hypothesized that color M-mode (CMM) images could be used to solve the Euler equation, yielding regional pressure gradients along the scanline, which could then be integrated to yield the unsteady Bernoulli equation and estimate noninvasively both the convective and inertial components of the transmitral pressure difference. BACKGROUND: Pulsed and continuous wave Doppler velocity measurements are routinely used clinically to assess severity of stenotic and regurgitant valves. However, only the convective component of the pressure gradient is measured, thereby neglecting the contribution of inertial forces, which may be significant, particularly for nonstenotic valves. Color M-mode provides a spatiotemporal representation of flow across the mitral valve. METHODS: In eight patients undergoing coronary artery bypass grafting, high-fidelity left atrial and ventricular pressure measurements were obtained synchronously with transmitral CMM digital recordings. The instantaneous diastolic transmitral pressure difference was computed from the M-mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation and was compared to the catheter measurements. RESULTS: From 56 beats in 16 hemodynamic stages, inclusion of the inertial term ([deltapI]max = 1.78+/-1.30 mm Hg) in the noninvasive pressure difference calculation significantly increased the temporal correlation with catheter-based measurement (r = 0.35+/-0.24 vs. 0.81+/-0.15, p< 0.0001). It also allowed an accurate approximation of the peak pressure difference ([deltapc+I]max = 0.95 [delta(p)cathh]max + 0.24, r = 0.96, p<0.001, error = 0.08+/-0.54 mm Hg). CONCLUSIONS: Inertial forces are significant components of the maximal pressure drop across the normal mitral valve. These can be accurately estimated noninvasively using CMM recordings of transmitral flow, which should improve the understanding of diastolic filling and function of the heart.
Paranormal healing and hypertension
Beutler, Jaap J; Attevelt, Johannes T M; Schouten, Sybo A; Faber, Joop A J; Mees, Evert J Dorhout; Geijskes, Gijsbert G
1988-01-01
A prospective randomised trial was carried out to see whether paranormal healing by laying on of hands might reduce blood pressure in essential hypertension and whether such an effect might be due to a paranormal, psychological, or placebo factor. Patients were randomised to three treatment groups: paranormal healing by laying on of hands (n=40), paranormal healing at a distance (n=37), and no paranormal healing (controls; n=38). Healing at a distance and no paranormal healing were investigated double blind. Systolic and diastolic blood pressures were significantly reduced in all three groups at week 15 (mean reduction (95% confidence interval) 17·1 (14·0 to 20·2)/8·3 (6·6 to 10·0) mm Hg). Only the successive reductions in diastolic blood pressures among the groups from week to week were significantly different. Each week diastolic pressure was consistently lower (average 1·9 mm Hg) after healing at a distance compared with control, but on paired comparison these differences were not significant. Probably week to week variations among the groups accounted for any differences noted. In this study no treatment was consistently better than another and the data cannot therefore be taken as evidence of a paranormal effect on blood pressure. Probably the fall in blood pressure in all three groups either was caused by the psychosocial approach or was a placebo effect of the trial itself. PMID:3134082
Turgay Yildirim, O; Gonullu, E; Aydin, F; Aksit, E; Huseyinoglu Aydin, A; Dagtekin, E
2018-04-12
Rheumatoid arthritis (RA) is a systemic autoimmune inflammatory disorder which further doubles the risk of developing cardiovascular disease. Some studies suggest that in RA patients, the prevalence of hypertension increases due to prednisolone use, clinical status, genetic factors, and physical inactivity. On the other hand, dipper and non-dipper status in RA patients compared to non-RA subjects has not been investigated to our knowledge. Purpose of the study is to investigate whether non-dipper status is more deteriorated in RA patients. Sixty-five RA patients and 61 age-sex-matched control patients were evaluated in this cross-sectional study. Patients were classified according to 24-h ambulatory blood pressure monitoring results. Patients with previous hypertension diagnosis, coronary artery disease, and abnormal kidney function were excluded. Mean age of the study sample was 53.7 ± 12.3 years and 40.5% were male. There was no significant difference between groups in terms of basic demographic characteristics. Leukocyte counts (p = 0.001), neutrophil counts (p = 0.001), and red cell distribution width (p = 0.000) were significantly higher in the RA group. ABPM results indicate no significant difference between RA patients and the control group in terms of daytime systolic and diastolic blood pressure, nighttime systolic and diastolic blood pressure, and average systolic and diastolic blood pressure results (p > 0.05). There was no statistical difference regarding the non-dipper status of patient groups (p = 0.412). Nocturnal blood pressure dipping was significantly similar between groups (p = 0.980). In conclusion, RA patients have similar values in terms of nocturnal blood pressure dipping and hypertension diagnosis as compared to normal population.
Ambulatory blood pressure and heart rate during shuttle flight, entry and landing
NASA Technical Reports Server (NTRS)
Thornton, W.; Moore, T. P.; Uri, J.
1993-01-01
Ambulatory blood pressures (BP) and heart rates (HR) were recorded on a series of early Shuttle flights during preflight and pre-entry, entry, landing and egress. There were no significant differences between flight and preflight values during routine activity. Systolic blood pressure was slightly elevated in the deorbit period and systolic and diastolic blood pressure and heart rates were all elevated with onset of gravitoinertial loads and remained so through egress. Two of seven subjects had orthostatic problems in egress but their data did not show significant differences from others except in heart rate. Comparison of this data to that from recent studies show even larger increase in HR/BP values during current deorbit and entry phases which is consistent with increased heat and weight loads imposed by added survival gear. Both value and limitations of ambulatory heart rate/blood pressure data in this situation are demonstrated.
Effects of aromatherapy massage on blood pressure and lipid profile in korean climacteric women.
Hur, Myung-Haeng; Oh, Heeyoung; Lee, Myeong Soo; Kim, Chan; Choi, Ae-Na; Shin, Gil-Ran
2007-09-01
This study investigated the effects of aromatherapy massage on the lipid profile and blood pressure in Korean climacteric women. A wait-listed control group, pretest-posttest design was used. The subjects comprised 58 climacteric women: 30 in the experimental group and 28 in the control group. Aromatherapy massage using lavender, rose geranium, rose, and jasmine was given to the experimental group only. Each massage session lasted 30 minutes, and was performed once weekly for two 8-week periods with self abdominal daily massage at home. The intervention produced significant differences in the systolic blood pressure compare to pretreatment and significant differences in systolic and diastolic blood pressures at posttreatment between the two groups. These results suggest that aromatherapy massage may exert positive effects on blood pressure. However, more objective, clinical measures should be applied in a future study with a randomized placebo-controlled design.
Effect of revised high-heeled shoes on foot pressure and static balance during standing.
Bae, Young-Hyeon; Ko, Mansoo; Park, Young-Soul; Lee, Suk-Min
2015-04-01
[Purpose] The purpose of this study was to investigate the effects of revised high-heeled shoes on the foot pressure ratio and static balance during standing. [Subjects and Methods] A single-subject design was used, 15 healthy women wearing revised high-heeled shoes and general high-heeled shoes in a random order. The foot pressure ratio and static balance scores during standing were measured using a SpaceBalance 3D system. [Results] Forefoot and rearfoot pressures were significantly different between the 2 types of high-heeled shoes. Under the 3 conditions tested, the static balance score was higher for the revised high-heeled shoes than for the general high-heeled shoes, but this difference was not statistically significant. [Conclusion] Revised high-heeled shoes are preferable to general high-heeled shoes, as they result in normalization of normalized foot pressure and a positive effect on static balance.
NASA Astrophysics Data System (ADS)
Suhana; Srilestari, A.; Marbun, M. B. H.; Mihardja, H.
2017-08-01
Hypertension is common a health problem and its prevalence in Indonesia is quite high (31.7%). Catgut embedding—an acupuncture technique—is known to reduce blood pressure; however, no study has confirmed the underlying mechanism. This study examines the effect of catgut embedding on serum nitric oxide (NO) concentration and blood pressure in patients with essential hypertension. Forty hypertension patients were randomly assigned to two groups: the control group received anti-hypertensive drugs whereas the case group received anti-hypertensive drugs and catgut embedding. Results showed a statistically significant mean difference in NO concentration (p < 0.05) and statistically and clinically significant mean difference in systolic and diastolic blood pressure between the two groups (p < 0.05). The results confirm that catgut embedding can influence serum NO concentration and blood pressure in essential hypertension patients.
Effect of revised high-heeled shoes on foot pressure and static balance during standing
Bae, Young-Hyeon; Ko, Mansoo; Park, Young-Soul; Lee, Suk-Min
2015-01-01
[Purpose] The purpose of this study was to investigate the effects of revised high-heeled shoes on the foot pressure ratio and static balance during standing. [Subjects and Methods] A single-subject design was used, 15 healthy women wearing revised high-heeled shoes and general high-heeled shoes in a random order. The foot pressure ratio and static balance scores during standing were measured using a SpaceBalance 3D system. [Results] Forefoot and rearfoot pressures were significantly different between the 2 types of high-heeled shoes. Under the 3 conditions tested, the static balance score was higher for the revised high-heeled shoes than for the general high-heeled shoes, but this difference was not statistically significant. [Conclusion] Revised high-heeled shoes are preferable to general high-heeled shoes, as they result in normalization of normalized foot pressure and a positive effect on static balance. PMID:25995572
Designing and Constructing an Optical Monitoring System of Blood Supply to Tissues under Pressure.
Hadi, Akbari; Amin, Younessi Heravi Mohammad
2012-04-01
Reduced blood flow due to obstruction is in most cases a primary factor in pressure ulcer formation and creation of bedsores. The aim of this study is to design and manufacture a care system for tissue under pressure, based on variations in blood flow at different depths of tissue. In the manufacture of the system two infrared light transmitters and receivers were located between 5 and 10 mm depth to measure the flow of blood at different in the under- pressure heel tissue. In addition, blood flow was evaluated in an unloaded and loaded condition, with 30 mmHg and 60.0 mmHg. A total of 15 people participated with a mean age of 50. Of these 15; 9 (60%) were men and 6 (40%) were women. Primary measurement results showed different individual differences in variation of blood flow in the tissue. To study signal amplitude changes significantly influenced by external pressure the PPG, P-value was measured. It was noted that there were significant changes in PPG signal amplitude during loading both pressures of 30 and 60 mmHg. Further development of this system would be possible with the use of a more flexible probe and by using a stronger optical receiver and transmitter to access more depth.
Takizawa, Ken; Matsumae, Mitsunori; Hayashi, Naokazu; Hirayama, Akihiro; Yatsushiro, Satoshi; Kuroda, Kagayaki
2017-10-18
Magnetic resonance imaging (MRI) does not only ascertain morphological features, but also measures physiological properties such as fluid velocity or pressure gradient. The purpose of this study was to investigate cerebrospinal fluid (CSF) dynamics in patients with morphological abnormalities such as enlarged brain ventricles and subarachnoid spaces. We used a time-resolved three dimensional phase contrast (3D-PC) MRI technique to quantitatively evaluate CSF dynamics in the Sylvian aqueduct of healthy elderly individuals and patients with either idiopathic normal pressure hydrocephalus (iNPH) or Alzheimer's disease (AD) presenting with ventricular enlargement. Nineteen healthy elderly individuals, ten iNPH patients, and seven AD patients (all subjects ≥ 60 years old) were retrospectively evaluated 3D-PC MRI. The CSF velocity, pressure gradient, and rotation in the Sylvian aqueduct were quantified and compared between the three groups using Kolmogorov-Smirnov and Mann-Whitney U tests. There was no statistically significant difference in velocity among the three groups. The pressure gradient was not significantly different between the iNPH and AD groups, but was significantly different between the iNPH group and the healthy controls (p < 0.001), and similarly, between the AD group and the healthy controls (p < 0.001). Rotation was not significantly different between the iNPH and AD groups, but was significantly different between the iNPH group and healthy controls (p < 0.001), and similarly, between the AD group and the healthy controls (p < 0.001). Quantitative analysis of CSF dynamics with time resolved 3D-PC MRI revealed differences and similarities in the Sylvian aqueduct between healthy elderly individuals, iNPH patients, and AD patients. The results showed that CSF motion is in a hyperdynamic state in both iNPH and AD patient groups compared to healthy elderly individuals, and that iNPH patients and AD patients display similar CSF motion profiles.
Seo, Jeong-Hee; Li, Guoan; Shetty, Gautam M; Kim, Ji-Hoon; Bae, Ji-Hoon; Jo, Myoung-Lae; Kim, Jung-Sung; Lee, Sung-Jae; Nha, Kyung-Wook
2009-11-01
Our purpose was to evaluate the result of radial tears at the root of the posterior horn of the medial meniscus (PHMM) in terms of tibiofemoral contact mechanics and the effectiveness of pullout sutures for such tears. Eleven mature pig knees each underwent 15 different testing conditions with an intact, simulated (incised) radial tear at the root of the PHMM and placement of pullout sutures in the radial tears of the medial meniscus at 5 different angles of flexion (0 degrees, 15 degrees, 30 degrees, 60 degrees, and 90 degrees ) under a 1,500-N axial load. A K-Scan pressure sensor (Tekscan, Boston, MA) was used to measure medial tibiofemoral contact area and peak tibiofemoral contact pressure. Data were analyzed to assess the difference in medial contact area and tibiofemoral peak contact pressure among the 3 meniscal conditions at various degrees of knee flexion. The mean contact area was significantly lower, and the peak tibiofemoral contact pressure was significantly high in knees with simulated radial tears at all angles of knee flexion compared with knees with intact menisci (P < .0001). The peak tibiofemoral contact pressure after the pullout suture technique was significantly high at 0 degrees and 15 degrees of flexion (P < .0001) compared with intact knee specimens. Failure of sutures occurred in 45% of the specimens at 0 degrees of flexion. Radial tears at the root of the PHMM in a porcine model significantly increased medial tibiofemoral contact pressure and decreased contact area. Although repair of tears of the PHMM with the pullout suture technique aids in significantly reducing tibiofemoral peak contact pressure between 30 degrees and 90 degrees , it remains significantly high at 0 degrees and 15 degrees of flexion. Pullout sutures for radial tears at the root of the PHMM may lead to an increase in peak medial tibiofemoral contact pressure and may be prone to mechanical failure, especially during the stance (loading) phase of gait (mean, 15 degrees of flexion).
Stagegaard, Julia; Hørlyck, Arne; Hydeskov, Helle B; Bertelsen, Mads F
2017-06-01
Six clinically healthy captive cheetahs ( Acinonyx jubatus ) were anesthetized twice using two different drug combinations to investigate if blood pressure and kidney blood flow are affected by medetomidine dosage. Protocol KM (2.0 mg/kg ketamine and 0.05 mg/kg medetomidine) was compared with protocol KMM (2.0 mg/kg ketamine, 0.02 mg/kg medetomidine, and 0.1 mg/kg midazolam). Heart rate (HR), respiratory rate (RR), body temperature, end-tidal carbon dioxide pressure (ETCO 2 ), and anesthetic depth were monitored every 10 min. Noninvasive mean (MAP), systolic (SAP), and diastolic (DAP) arterial blood pressure were measured, and Duplex Doppler ultrasonography was performed on the kidneys. The mean arterial resistive index (RI) was determined and the pulse pressure index (PPI) was calculated, as indicators for kidney blood flow. There were no significant differences in induction and recovery times. MAP was significantly higher with KM than KMM at 35 min, and in both protocols decreased significantly after atipamezole administration. DAP was significantly higher at 25 and 35 min in animals anesthetized with KM; it also decreased significantly with both protocols after atipamezole administration. The PPI was significantly lower throughout the procedure with KM, and with both protocols increased significantly after atipamezole administration. Both the higher blood pressure and the reduced PPI with KM were likely a direct effect of the higher medetomidine dosage, and these findings indicate that lower medetomidine dosages might reduce hypertension and lead to a better PPI in cheetah immobilization.
Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary
2010-11-01
To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.
Topçu, H O; Cavkaytar, S; Kokanalı, K; Guzel, A I; Islimye, M; Doganay, M
2014-11-01
To determine the effects of different intra-abdominal pressure values on visceral pain following gynecologic laparoscopic surgery in the Trendelenburg position. This randomized, controlled prospective trial was conducted at a tertiary education hospital and included 150 patients who underwent gynecologic laparoscopy with different abdominal insufflation pressures. There were 54 patients in the 8 mmHg low pressure group (LPG), 45 in the 12 mmHg standard pressure group (SPG), and 51 in the 15 mmHg high pressure group (HPG). We assessed mean age, body mass index (BMI), duration of surgery, analgesic consumption, length of hospital stay, amount of CO2 expended and volume of hemorrhage. Visceral pain and referred visceral pain were assessed 6, 12, and 24 h postoperatively using a visual analog scale (VAS). There was no significant difference in age, BMI, analgesic consumption or length of hospital stay among groups. The mean operative time and total CO2 expended during surgery were higher in the LPG compared with the SPG and HPG. The mean intensity of postoperative pain assessed by the VAS score at 6 and 12 h was less in the LPG than in the SPG and HPG and was reduced significantly at 12 h. VAS scores at 24 h in the LPG and SPG were lower than in the HPG. Pain is reduced by low insufflation pressure compared with standard and high insufflation pressure following gynecologic laparoscopic surgery in the Trendelenburg position. However, low insufflation pressure may result in longer operation times and increased hemorrhage. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Da Roza, T; Mascarenhas, T; Araujo, M; Trindade, V; Jorge, R Natal
2013-09-01
To compare pelvic floor muscle strength in nulliparous sports students measured using the modified Oxford Grading Scale and a Peritron manometer; and to compare the manometric measurements between continent and incontinent subjects. Cross-sectional study. All subjects were evaluated twice on the same day; first by vaginal digital examination and subsequently by vaginal pressure using a Peritron manometer. Forty-three nulliparous female sports students [mean age 21 (standard deviation 4) years] from the Sports Faculty of the University of Porto. This study found a significant moderate correlation between the Oxford Grading Scale score and peak pressure on manometry (r=0.646, P=0.002). Mean maximal strength for the entire group was 70.4cmH2O (range 21 to 115cmH2O). Out of 43 subjects, 37% (n=16) demonstrated signs of incontinence. On manometry, no significant differences were found in vaginal resting pressure or peak pressure between the continent and incontinent groups. There was moderate correlation between peak pressure on manometry and the Oxford Grading Scale score. Peritron manometer measurements of pelvic floor muscle contractions showed no significant differences in vaginal resting pressure and peak pressure in continent and incontinent subjects. Copyright © 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Yanagisawa, Yukio; Matsuo, Yoshimi; Shuntoh, Hisato; Horiuchi, Noriaki
2014-01-01
[Purpose] The purpose of this study was to elucidate the effect of expiratory resistive loading on orbicularis oris muscle activity. [Subjects] Subjects were 23 healthy individuals (11 males, mean age 25.5±4.3 years; 12 females, mean age 25.0±3.0 years). [Methods] Surface electromyography was performed to measure the activity of the orbicularis oris muscle during maximum lip closure and resistive loading at different expiratory pressures. Measurement was performed at 10%, 30%, 50%, and 100% of maximum expiratory pressure (MEP) for all subjects. The t-test was used to compare muscle activity between maximum lip closure and 100% MEP, and analysis of variance followed by multiple comparisons was used to compare the muscle activities observed at different expiratory pressures. [Results] No significant difference in muscle activity was observed between maximum lip closure and 100% MEP. Analysis of variance with multiple comparisons revealed significant differences among the different expiratory pressures. [Conclusion] Orbicularis oris muscle activity increased with increasing expiratory resistive loading. PMID:24648644
Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B
2017-10-01
To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P < .005 and all P < .037, respectively), decreased mean contact pressure at all flexion angles (all P < .007 and all P < .001, respectively) except for 0° (P = .097 and P = .39, respectively), and decreased peak contact pressure at all flexion angles (all P < .001, all P < .001, respectively) except for 0° (P = .080 and P = .544, respectively). However, there were significant differences in contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P < .014 and all P < .032, respectively). Additionally, there were significant differences between the intact state and all-inside technique in contact area at 60° and 90° and peak contact pressure at 90° (both P < .005 and P = .004, respectively). Median values of intact contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of displaced bucket-handle tears of the medial meniscus. Thus, both techniques may adequately decrease the likelihood of cartilage degeneration. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Effects of negative pressures on epithelial tight junctions and migration in wound healing.
Hsu, Chih-Chin; Tsai, Wen-Chung; Chen, Carl Pai-Chu; Lu, Yun-Mei; Wang, Jong-Shyan
2010-08-01
Negative-pressure wound therapy has recently gained popularity in chronic wound care. This study attempted to explore effects of different negative pressures on epithelial migration in the wound-healing process. The electric cell-substrate impedance sensing (ECIS) technique was used to create a 5 x 10(-4) cm(2) wound in the Madin-Darby canine kidney (MDCK) and human keratinocyte (HaCaT) cells. The wounded cells were cultured in a negative pressure incubator at ambient pressure (AP) and negative pressures of 75 mmHg (NP(75)), 125 mmHg (NP(125)), and 175 mmHg (NP(175)). The effective time (ET), complete wound healing time (T(max)), healing rate (R(heal)), cell diameter, and wound area over time at different pressures were evaluated. Traditional wound-healing assays were prepared for fluorescent staining of cells viability, cell junction proteins, including ZO-1 and E-cadherin, and actins. Amount of cell junction proteins at AP and NP(125) was also quantified. In MDCK cells, the ET (1.25 +/- 0.27 h), T(max) (1.76 +/- 0.32 h), and R(heal) (2.94 +/- 0.62 x 10(-4) cm(2)/h) at NP(125) were significantly (P < 0.01) different from those at three other pressure conditions. In HaCaT cells, the T(max) (7.34 +/- 0.29 h) and R(heal) (6.82 +/- 0.26 x 10(-5) cm(2)/h) at NP(125) were significantly (P < 0.01) different from those at NP(75). Prominent cell migration features were identified in cells at the specific negative pressure. Cell migration activities at different pressures can be documented with the real-time wound-healing measurement system. Negative pressure of 125 mmHg can help disassemble the cell junction to enhance epithelial migration and subsequently result in quick wound closure.
Peeters, Harry Huiz; De Moor, Roeland J G
2015-07-01
The use of Er,Cr:YSGG laser to activate irrigants results in the creation of vapour bubbles and shockwaves. The present study evaluated the magnitude of pressure changes in the root canal during laser-activated irrigation. The root canal of a single extracted maxillary canine was enlarged to a size 40/0.06 file. A pressure sensor was inserted apically into the root canal. The tooth was processed as follows. In the EDTA condition, the tooth was irrigated with 17 % EDTA; in the NaOCl condition, the tooth was irrigated with 3 % NaOCl. In all conditions, the irrigants were activated at 0.75 and 1.75 W for 60 s using RFT2 and MZ2 tips; to analyse the effect of tip placement, the tip was activated at the orifice and after inserting the tip 5 mm deeper than the orifice. Data showed no significant difference between irrigation regimens (p > 0.05). There were no significant differences of the pressure between RFT2 and MZ2 tips (p > 0.05). The placement of tips closer to the apex resulted in significantly higher pressure than at the orifice (p < 0.001). The use of 1.75 W power resulted in a significantly higher increase of pressure compared to 0.75 W (p < 0.001), regardless either the type of solutions or tips used. The magnitude of the pressure changes in the root canal at 0.75 W was significantly lower than 1.75 W regardless of either type of tips or solutions used. The closer the insertion of the tip to the apex, the higher the pressure.
Compressed storage of arterial pressure waveforms by selection of significant points.
de Graaf, P M; van Goudoever, J; Wesseling, K H
1997-09-01
Continuous records of arterial blood pressure can be obtained non-invasively with Finapres, even for periods of 24 hours. Increasingly, storage of such records is done digitally, requiring large disc capacities. It is therefore necessary to find methods to store blood pressure waveforms in compressed form. The method of selection of significant points known from ECG data compression is adapted. Points are selected as significant wherever the first derivative of the pressure wave changes sign. As a second stage recursive partitioning is used to select additional points such that the difference between the selected points, linearly interpolated, and the original curve remains below a maximum. This method is tested on finger arterial pressure waveform epochs of 60 s duration taken from 32 patients with a wide range of blood pressures and heart rates. An average compression factor of 4.6 (SD 1.0) is obtained when accepting a maximum difference of 3 mmHg. The root mean squared error is 1 mmHg averaged over the group of patient waveforms. Clinically relevant parameters such as systolic, diastolic and mean pressure are reproduced with an offset error of less than 0.5 (0.3) mmHg and scatter less than 0.6 (0.1) mmHg. It is concluded that a substantial compression factor can be achieved with a simple and computationally fast algorithm and little deterioration in waveform quality and pressure level accuracy.
Gunningberg, Lena; Brudin, Lars; Idvall, Ewa
2010-09-01
To describe and compare pressure ulcer prevalence in two county councils and concurrently explore Nurse Managers' perspective of contextual factors in a hospital organization. Despite good knowledge about risk factors and prevention of pressure ulcers, the prevalence of pressure ulcers remains high. Nurse Managers' have a key role in implementing evidence-based practice. The present study included five hospitals in two Swedish county councils: county council A (non-university setting) and county council B (university setting). A pressure ulcer prevalence study was conducted according to the methodology developed by the European Pressure Ulcer Advisory Panel. The Nurse Managers' answered a (27-item) questionnaire on contextual factors. County council B had significantly less pressure ulcers grade (2-4) (7.7%) than county council A (11.3%). The Nurse Managers' assessed only two out of the 27 general contextual items significantly differently. Some significant differences were observed in ward organization. In county council B, the Nurse Managers' seemed more aware of prevention strategies compared with Nurse Managers' in county council A. The Nurse Managers' should take more responsibility to develop the prerequisite for quality improvement in nursing. Nursing outcomes (e.g. pressure ulcers) should be incorporated into national quality registries for benchmarking and Nurse Managers' competence in evidence-based practice and research methodology increased. © 2010 The Authors. Journal compilation © 2010 Blackwell Publishing Ltd.
Kwak, Jae Gun; Lee, Jinkwon; Park, Minkyoung; Seo, Yu-Jin; Lee, Chang-Ha
2017-03-01
This study examined the degree of hemolysis during vacuum-assisted venous drainage at different negative pressures to identify an adequate negative pressure that provides effective venous drainage without significant hemolysis in open-heart surgery in children weighing less than 10 kg. Patients weighing less than 10 kg who underwent surgery for ventricular septal defect or atrial septal defect from 2011 to 2014 were enrolled. We used one of four negative pressures (20, 30, 40, or 60 mm Hg) for each patient. We measured haptoglobin, plasma hemoglobin, aspartate aminotransferase, and lactate dehydrogenase levels in the patients' blood three times perioperatively and determined the potential correlation between the change in each parameter with the level of negative pressure. Forty-six patients were enrolled in this study (mean age: 7.1 ± 7.0 months, mean body weight: 6.1 ± 1.8 kg). There were no significant differences according to the degree of negative pressure with respect to patient age, body weight, cardiopulmonary bypass (CPB) time, aorta cross-clamping time, blood flow during CPB, or lowest body temperature. All parameters that we measured reflected progression of hemolysis during CPB; however, the degree of change in the parameters did not correlate with negative pressure. In pediatric patients weighing less than 10 kg, the change in the degree of hemolysis did not differ with the amount of negative pressure. We may apply negative pressures up to 60 mm Hg without increasing the risk of hemolysis, with almost same the level of hemolysis using negative pressures of 20, 30, and 40 mm Hg for effective venous drainage and an ideal operative field during open-heart surgery.
Plateau Waves of Intracranial Pressure and Partial Pressure of Cerebral Oxygen.
Lang, Erhard W; Kasprowicz, Magdalena; Smielewski, Peter; Pickard, John; Czosnyka, Marek
2016-01-01
This study investigates 55 intracranial pressure (ICP) plateau waves recorded in 20 patients after severe traumatic brain injury (TBI) with a focus on a moving correlation coefficient between mean arterial pressure (ABP) and ICP, called PRx, which serves as a marker of cerebrovascular reactivity, and a moving correlation coefficient between ABP and cerebral partial pressure of oxygen (pbtO2), called ORx, which serves as a marker for cerebral oxygen reactivity. ICP and ICPamplitude increased significantly during the plateau waves, whereas CPP and pbtO2 decreased significantly. ABP, ABP amplitude, and heart rate remained unchanged. In 73 % of plateau waves PRx increased during the wave. ORx showed an increase during and a decrease after the plateau waves, which was not statistically significant. Our data show profound cerebral vasoparalysis on top of the wave and, to a lesser extent, impairment of cerebral oxygen reactivity. The different behavior of the indices may be due to the different latencies of the cerebral blood flow and oxygen level control mechanisms. While cerebrovascular reactivity is a rapidly reacting mechanism, cerebral oxygen reactivity is slower.
Increased nocturnal blood pressure in enuretic children with polyuria.
Kruse, Anne; Mahler, Birgitte; Rittig, Soren; Djurhuus, Jens Christian
2009-10-01
We investigated the association between nocturnal blood pressure and urine production in children with enuresis. A total of 39 consecutive children with a mean age of 9.8 years (range 6.2 to 14.9) with monosymptomatic nocturnal enuresis completed a bladder diary, including 2 weeks of basic documentation and 2 with desmopressin titration from 120 to 240 microg sublingually. Arterial blood pressure was measured every 30 minutes during 24 hours and during 4 additional nights using an ambulatory blood pressure monitor. Furthermore, 10 healthy children were recruited into the study who completed a bladder diary for 5 days while measuring arterial blood pressures with documentation of all intake and voided volumes. Patients with nocturnal polyuria had significantly higher nocturnal mean arterial pressure than patients without polyuria and controls (p <0.05). Furthermore, a positive correlation was seen between nocturnal urine output and nocturnal mean arterial pressure (r = 0.32, p <0.001). Nocturnal urine output was significantly higher during wet nights than dry nights (p <0.001). However, no significant difference was found in mean arterial pressure between wet and dry nights. Nocturnal mean arterial pressure was significantly higher in children with enuresis with polyuria than in children without polyuria. There was a significant positive correlation between average nocturnal mean arterial pressure and nocturnal urine volume in the whole study. The association between nocturnal blood pressure and urine volume, and the role of blood pressure should be investigated in a larger group of children with enuresis who have nocturnal polyuria.
Influence of computer work under time pressure on cardiac activity.
Shi, Ping; Hu, Sijung; Yu, Hongliu
2015-03-01
Computer users are often under stress when required to complete computer work within a required time. Work stress has repeatedly been associated with an increased risk for cardiovascular disease. The present study examined the effects of time pressure workload during computer tasks on cardiac activity in 20 healthy subjects. Heart rate, time domain and frequency domain indices of heart rate variability (HRV) and Poincaré plot parameters were compared among five computer tasks and two rest periods. Faster heart rate and decreased standard deviation of R-R interval were noted in response to computer tasks under time pressure. The Poincaré plot parameters showed significant differences between different levels of time pressure workload during computer tasks, and between computer tasks and the rest periods. In contrast, no significant differences were identified for the frequency domain indices of HRV. The results suggest that the quantitative Poincaré plot analysis used in this study was able to reveal the intrinsic nonlinear nature of the autonomically regulated cardiac rhythm. Specifically, heightened vagal tone occurred during the relaxation computer tasks without time pressure. In contrast, the stressful computer tasks with added time pressure stimulated cardiac sympathetic activity. Copyright © 2015 Elsevier Ltd. All rights reserved.
Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli
2014-10-01
To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P < 0.001). After using a ΔP of 3 cmH(2)O for the cutoff value (ΔP was defined as the difference of automatic titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P < 0.001). However, there were no differences for the pressure of manual titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.
Sousa, Nelson; Mendes, Romeu; Abrantes, Catarina; Sampaio, Jaime; Oliveira, José
2013-08-01
This randomized study evaluated the impact of different exercise training modalities on blood pressure and body fat responses in apparently healthy older men. Forty-eight elderly men (aged 65-75 years) were randomly assigned to an aerobic training group (ATG, n=15), a combined aerobic and resistance training group (CTG, n=16), or a control group (n=17). Both exercise training programs were moderate-to-vigorous intensity, three days/week for 9-months. Strength, aerobic endurance, body fat and blood pressure were measured on five different occasions. The data were analyzed using a mixed-model ANOVA, and the independence between systolic blood pressure (SBP), diastolic blood pressure (DBP) and group was tested. A significant main effect of group (p<0.001) was observed in strength and aerobic endurance, with higher performance observed in the CTG. A significant main effect of group (p<0.001) and time (p=0.029) was observed in body fat percentage, with a 2.3% decrease in CTG. A significant main effect of time was observed in SBP (p=0.005) and in DBP (p=0.011) for both ATG and CTG. Mean decreases in SBP and DBP, respectively, were 15 and 6 mmHg for ATG and 24 and 12 mmHg for CTG. There was a significant association for SBP (p=0.008) and DBP (p=0.005) in the CTG, with significant individual BP profile modifications. Both exercise-training programs reduce resting blood pressure. However, only the combined exercise training was effective at reducing body fat percentage; consequently, there were larger changes in blood pressure, which result in a significant reduction in hypertensive subjects. Copyright © 2013 Elsevier Inc. All rights reserved.
Blood pressure and serum creatinine in obese female.
Asrin, M; Nessa, A; Hasan, M I; Das, R K
2015-01-01
Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (p<0.0001). The examinations and biochemical investigations revealed that high BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.
High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm.
Olbers, Joakim; Gille, Adam; Ljungman, Petter; Rosenqvist, Mårten; Östergren, Jan; Witt, Nils
2018-02-07
Atrial fibrillation (AF) is associated with an increased risk for cardiovascular morbidity and mortality, not entirely explained by thromboembolism. The underlying mechanisms for this association are largely unknown. Similarly, high blood pressure (BP) increases the risk for cardiovascular events. Despite this the interplay between AF and BP is insufficiently studied. The purpose of this study was to examine and quantify the beat-to-beat blood pressure variability in patients with AF in comparison to a control group of patients with sinus rhythm. We studied 33 patients - 21 in atrial fibrillation and 12 in sinus rhythm - undergoing routine coronary angiography. Invasive blood pressure was recorded at three locations: radial artery, brachial artery and ascending aorta. Blood pressure variability, defined as average beat-to-beat blood pressure difference, was calculated for systolic and diastolic blood pressure at each site. We observed a significant difference (p < .001) in systolic and diastolic blood pressure variability between the atrial fibrillation and sinus rhythm groups at all locations. Systolic blood pressure variability roughly doubled in the atrial fibrillation group compared to the sinus rhythm group (4.9 and 2.4 mmHg respectively). Diastolic beat-to-beat blood pressure variability was approximately 6 times as high in the atrial fibrillation group compared to the sinus rhythm group (7.5 and 1.2 mmHg respectively). No significant difference in blood pressure variability was seen between measurement locations. Beat-to-beat blood pressure variability in patients with atrial fibrillation was substantially higher than in patients with sinus rhythm. Hemodynamic effects of this beat-to-beat variation in blood pressure may negatively affect vascular structure and function, which may contribute to the increased cardiovascular morbidity and mortality seen in patients with atrial fibrillation.
McKinney, Timothy B; Babin, Elizabeth A; Ciolfi, Veronica; McKinney, Cynthia R; Shah, Nima
2018-04-01
Air-charged (AC) and water-perfused (WP) catheters have been evaluated for differences in measuring pressures for voiding dysfunction. Typically, a two-catheter system was used. We believe that simultaneous pressure measurements with AC and WP in a single catheter will provide analogous pressures for coughs, Valsalvas, and maximum pressures in voiding pressure studies (VPS). This IRB approved prospective study included 50 women over age 21. AC dual TDOC catheters were utilized. The water-filling channel served as the bladder filler and the water pressure readings. Patients were evaluated with empty bladders and at volumes of 50-100 mL, 200 mL, and maximum capacity with cough and Valsalva maneuvers. Comparative analysis was performed on maximum stress peak pressures. At maximum bladder capacity, VPS was done and maximum voiding pressure was recorded. Comparing coughs and Valsalva maneuvers pressures, there was significant increase in variability between AC and WP measurements with less than 50 mL volume (P < 0.001). Significant correlations were observed between AC and WP measurements for coughs and Valsalvas with bladder volume over 50 mL. Visual impression showed virtually identical tracings. Cough measurements had an average difference of 0.25 cmH 2 O (±8.81) and Valsalva measurements had an average difference of 3.15 cmH 2 O (±4.72). Thirty-eight women had usable maximum voiding pressure measurements and had a strong correlation. Cystometrogram and maximum voiding pressure measurements done with either water or air charged catheters will yield similarly accurate results and are comparable. Results suggest more variability at low bladder volumes <50 mL. © 2018 Wiley Periodicals, Inc.
Hozawa, Atsushi; Ohkubo, Takayoshi; Obara, Taku; Metoki, Hirohito; Kikuya, Masahiro; Asayama, Kei; Totsune, Kazuhito; Hashimoto, Junichiro; Hoshi, Haruhisa; Arai, Yumiko; Satoh, Hiroshi; Hosokawa, Toru; Imai, Yutaka
2006-11-01
To explore the effect of personality on screening blood pressures measured in clinical settings and home blood pressure measurements. From 1997 to 1999, 699 participants underwent screening and home blood pressure measurements and completed the Japanese version of the short-form Eysenck personality questionnaire. An increased screening blood pressure was defined as screening blood pressure > or = 140/90 mmHg and an increased home blood pressure was defined as home blood pressure > or = 135/85 mmHg. Participants with lower extroversion scores (i.e., introversion) showed a greater difference between screening and home systolic blood pressure. The association between introversion and differences was statistically significant, even after adjustment for other possible factors (younger age, female, wide screening pulse pressure, never smoked, and no antihypertensive medication). The adjusted means of SBP differences were 7.3 and 4.4 mmHg among the lowest and highest extroversion quartiles, respectively (P for trend = 0.02). Other personality scores (psychoticism or neuroticism) were not associated with screening and home blood pressure differences. The incorporation of an extroversion score in the basic model consisting of the above factors that affected the difference between screening and home blood pressure slightly improved the prediction of a high home blood pressure. The area under the receiver operating characteristic curve increased by 0.037 among participants with high screening blood pressure and 0.006 for those with normal screening blood pressure compared with the basic model. Physicians may need to be aware of 'introverted' patients who have high blood pressure in clinic settings, because they have the potential for 'white-coat' hypertension.
Ji, Xunming; Li, Ke; Li, Wenbin; Li, Shuting; Yan, Feng; Gong, Wei; Luo, Yumin
2009-03-01
With the proposal of penumbra theory and development of intra-arterial thrombolysis (such as urokinase), the outcome of ischemic cerebrovascular disease is greatly improved. However, the incidence of hemorrhagic transformation (HT) increased concomitantly, and some studies showed a close relationship between blood pressure and HT. The mechanisms of blood pressure and urokinase effect on the incidence of HT are not clear. In this study, we investigated the effects of the different levels of blood pressure and urokinase on the ischemic lesions, the incidence of HT and the expression of matrix metalloproteinase 9 (MMP-9) in the rat ischemia-reperfusion models. Temporary focal ischemia was induced in male Sprague-Dawley rats using the intraluminal vascular occlusion method. The animals were assigned into four groups (n=11 in each group): low blood pressure group (LP), normal blood pressure group (NP), high blood pressure group (HP) and urokinase/high blood pressure group (UKHP). Adnephrin was applied to enhance the mean arterial blood pressure (MABP) at the beginning of reperfusion. MABP was maintained 20 mmHg higher than the baseline for 1 hour. Sodium nitroprusside was used to decrease MABP by 20 mmHg lower than the baseline for 1 hour. Both urokinase and adnephrin were used concomitantly in the UKHP group. Neurological deficit scores were evaluated at 2 hours (R2h) and 24 hours (R24h) after reperfusion. All rats were decapitated, their brains were sliced into 15-mum-thick slices, and the infarct volume and the visible HT were analysed. Three rats in each group were taken for immunohistochemistry and pathological analysis. There was no significant difference in MABP among the groups at the baseline time points (p>0.05), but blood pressure are definitely increased and decreased in the HP, UKHP, and LP groups. Neurological deficit scores showed no significant difference at R2h among the groups (p=0.443). However, neurological deficit scores showed significant differences at R24h among the groups, the neurological deficits scores of rats in the LP group are significantly higher than that in the other groups. Compared with that of 2 hours after reperfusion, neurological deficit scores deteriorated in the LP group (p=0.047) but was improved in the NP, HP and UKHP groups (p=0.076, 0.002, 0.017, respectively) at 24 hours after reperfusion. The infarct volume in the HP group was apparently smaller than that in the LP group (p=0.006). There was indeed a tendency that HT occurred more frequently in the UKHP group (42.8%) than in the HP (25%) and LP (28.5%) groups. MMP-9 expression showed significant increase around the ischemic lesion areas of the UKHP group and significant decrease in the cortical areas of the LP and HP groups but no significant difference in the basal ganglia of rats of all groups. Mild elevation of blood pressure during reperfusion is supposed to improve neurological outcomes in rats following ischemia/reperfusion. The incidence of HT tended to increase with the elevation of blood pressure and the administration of urokinase. Immunohistochemitry analysis indicated that incidence of HT may correlate with excessive expression of MMP-9.
Kandzari, David E; Böhm, Michael; Mahfoud, Felix; Townsend, Raymond R; Weber, Michael A; Pocock, Stuart; Tsioufis, Konstantinos; Tousoulis, Dimitrios; Choi, James W; East, Cara; Brar, Sandeep; Cohen, Sidney A; Fahy, Martin; Pilcher, Garrett; Kario, Kazuomi
2018-06-09
Previous catheter-based renal denervation studies have reported variable efficacy results. We aimed to evaluate safety and blood pressure response after renal denervation or sham control in patients with uncontrolled hypertension on antihypertensive medications with drug adherence testing. In this international, randomised, single-blind, sham-control, proof-of-concept trial, patients with uncontrolled hypertension (aged 20-80 years) were enrolled at 25 centres in the USA, Germany, Japan, UK, Australia, Austria, and Greece. Eligible patients had an office systolic blood pressure of between 150 mm Hg and 180 mm Hg and a diastolic blood pressure of 90 mm Hg or higher; a 24 h ambulatory systolic blood pressure of between 140 mm Hg and 170 mm Hg at second screening; and were on one to three antihypertensive drugs with stable doses for at least 6 weeks. Patients underwent renal angiography and were randomly assigned to undergo renal denervation or sham control. Patients, caregivers, and those assessing blood pressure were masked to randomisation assignments. The primary efficacy endpoint was blood pressure change from baseline (measured at screening visit two), based on ambulatory blood pressure measurements assessed at 6 months, as compared between treatment groups. Drug surveillance was used to assess medication adherence. The primary analysis was done in the intention-to-treat population. Safety events were assessed through 6 months as per major adverse events. This trial is registered with ClinicalTrials.gov, number NCT02439775, and follow-up is ongoing. Between July 22, 2015, and June 14, 2017, 467 patients were screened and enrolled. This analysis presents results for the first 80 patients randomly assigned to renal denervation (n=38) and sham control (n=42). Office and 24 h ambulatory blood pressure decreased significantly from baseline to 6 months in the renal denervation group (mean baseline-adjusted treatment differences in 24 h systolic blood pressure -7·0 mm Hg, 95% CI -12·0 to -2·1; p=0·0059, 24 h diastolic blood pressure -4·3 mm Hg, -7·8 to -0·8; p=0.0174, office systolic blood pressure -6·6 mm Hg, -12·4 to -0·9; p=0·0250, and office diastolic blood pressure -4·2 mm Hg, -7·7 to -0·7; p=0·0190). The change in blood pressure was significantly greater at 6 months in the renal denervation group than the sham-control group for office systolic blood pressure (difference -6·8 mm Hg, 95% CI -12·5 to -1·1; p=0·0205), 24 h systolic blood pressure (difference -7·4 mm Hg, -12·5 to -2·3; p=0·0051), office diastolic blood pressure (difference -3·5 mm Hg, -7·0 to -0·0; p=0·0478), and 24 h diastolic blood pressure (difference -4·1 mm Hg, -7·8 to -0·4; p=0·0292). Evaluation of hourly changes in 24 h systolic blood pressure and diastolic blood pressure showed blood pressure reduction throughout 24 h for the renal denervation group. 3 month blood pressure reductions were not significantly different between groups. Medication adherence was about 60% and varied for individual patients throughout the study. No major adverse events were recorded in either group. Renal denervation in the main renal arteries and branches significantly reduced blood pressure compared with sham control with no major safety events. Incomplete medication adherence was common. Medtronic. Copyright © 2018 Elsevier Ltd. All rights reserved.
Lei, Yun; Jin, Jiu; Ban, Haipeng; Du, Yuzheng
2017-11-12
To observe the effects of acupuncture combined with medication on circadian rhythm of blood pressure in patients with essential hypertension. Sixty-four patients of essential hypertension were randomly divided into an observation group and a control group, 32 cases in each group. All the patients maintained original treatment (taking antihypertensive medication); the patients in the observation group were treated with acupuncture method of " Huoxue Sanfeng , Shugan Jianpi ", once a day, five times per week, for totally 6 weeks (30 times). The circadian rhythm of blood pressure and related dynamic parameters were observed before and after treatment in the two groups. (1) The differences of daytime average systolic blood pressure (dASBP), daytime average diastolic blood pressure (dADBP), nighttime average systolic blood pressure (nASBP) and circadian rhythm of systolic blood pressure before and after treatment were significant in the observation group (all P <0.05); the differences of circadian rhythm of blood pressure and related dynamic parameters before and after treatment were insignificant in the control group (all P >0.05). The nASBP and circadian rhythm of systolic blood pressure in the observation group were significantly different from those in the control group (all P <0.05). (2) After the treatment, the spoon-shaped rate of circadian rhythm of blood pressure in the observation group was higher than that in the control group ( P <0.05). The acupuncture combined with medication could effectively improve the circadian rhythm of blood pressure and related dynamic parameters in patients with essential hypertension.
Tognetto, Daniele; Pastore, Marco R; Cirigliano, Gabriella; DʼAloisio, Rossella; Borelli, Massimo; De Giacinto, Chiara
2017-11-16
To investigate long-term intraocular pressure trends after uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane. Three hundred and sixty-eight eyes of 368 consecutive patients were enrolled. Changes in intraocular pressure 1, 3, 6, and 12 months after surgery and during the final follow-up visit were evaluated in vitrectomized eyes and nonvitrectomized fellow eyes. The median follow-up period was 36 months (range 12-92 months). Longitudinal data analysis evidenced a 2.5-mmHg (2.2 mmHg; 2.7 mmHg, 95% confidence interval) statistically significant difference in intraocular pressure 30 days after surgery between treated and fellow untreated eyes, gradually recovering to a not significant 0.2-mmHg (-0.1 mmHg; 0.4 mmHg, 95% confidence interval) difference within 26 months. The incidence of late-onset ocular hypertension was 5.7% (21 over 347, 2%; 12%, 95% confidence interval) without difference between the treated eyes and the group control. No significant difference in the incidence of late-onset ocular hypertension and sex, lens status, or gauge of vitrectomy instruments was detected. Only patient's age was significantly higher (mean difference 4.2 years; 0.1-8.0 years, Monte Carlo, 95% confidence interval) in those who developed late-onset ocular hypertension in the vitrectomized eye. Uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane seems not to increase the risk of late-onset ocular hypertension or open-angle glaucoma development.
Plantar Pressures During Long Distance Running: An Investigation of 10 Marathon Runners
Hohmann, Erik; Reaburn, Peter; Tetsworth, Kevin; Imhoff, Andreas
2016-01-01
The objective of this study was to record plantar pressures using an in-shoe measuring system before, during, and after a marathon run in ten experienced long-distance runners with a mean age of 37.7 ± 11.5 years. Peak and mean plantar pressures were recorded before, after, and every three km during a marathon race. There were no significant changes over time in peak and mean plantar pressures for either the dominant or non-dominant foot. There were significant between foot peak and mean plantar pressure differences for the total foot (p = 0.0001), forefoot (p = 0.0001), midfoot (p = 0.02 resp. p = 0.006), hindfoot (p = 0.0001), first ray (p = 0.01 resp. p = 0.0001) and MTP (p = 0.05 resp. p = 0.0001). Long-distance runners do not demonstrate significant changes in mean or peak plantar foot pressures over the distance of a marathon race. However, athletes consistently favoured their dominant extremity, applying significantly higher plantar pressures through their dominant foot over the entire marathon distance. Key points Fatigue does not increase foot pressures Every runner has a dominant foot where pressures are higher and that he/she favours Foot pressures do not increase over the distance of a marathon run PMID:27274662
Xu, Wei-Hua; Shen, Hua-Hao
2010-02-25
When using pressure-type plethysmography to test lung function of rodents, calculation of lung volume is always based on Boyle's law. The precondition of Boyle's law is that perfect air is static. However, air in the chamber is flowing continuously when a rodent breathes inside the chamber. Therefore, Boyle's law, a principle of air statics, may not be appropriate for measuring pressure changes of flowing air. In this study, we deduced equations for pressure changes inside pressure-type plethysmograph and then designed three experiments to testify the theoretic deduction. The results of theoretic deduction indicated that increased pressure was generated from two sources: one was based on Boyle's law, and the other was based on the law of conservation of momentum. In the first experiment, after injecting 0.1 mL, 0.2 mL, 0.4 mL of air into the plethysmograph, the pressure inside the chamber increased sharply to a peak value, then promptly decreased to horizontal pressure. Peak values were significantly higher than the horizontal values (P<0.001). This observation revealed that flowing air made an extra effect on air pressure in the plethysmograph. In the second experiment, the same volume of air was injected into the plethysmograph at different frequencies (0, 0.5, 1, 2, 3 Hz) and pressure changes inside were measured. The results showed that, with increasing frequencies, the pressure changes in the chamber became significantly higher (P<0.001). In the third experiment, small animal ventilator and pipette were used to make two types of airflow with different functions of time. The pressure changes produced by the ventilator were significantly greater than those produced by the pipette (P<0.001). Based on the data obtained, we draw the conclusion that, the flow of air plays a role in pressure changes inside the plethysmograph, and the faster the airflow is, the higher the pressure changes reach. Furthermore, the type of airflow also influences the pressure changes.
Increases in intramuscular pressure raise arterial blood pressure during dynamic exercise
NASA Technical Reports Server (NTRS)
Gallagher, K. M.; Fadel, P. J.; Smith, S. A.; Norton, K. H.; Querry, R. G.; Olivencia-Yurvati, A.; Raven, P. B.
2001-01-01
This investigation was designed to determine the role of intramuscular pressure-sensitive mechanoreceptors and chemically sensitive metaboreceptors in affecting the blood pressure response to dynamic exercise in humans. Sixteen subjects performed incremental (20 W/min) cycle exercise to fatigue under four conditions: control, exercise with thigh cuff occlusion of 90 Torr (Cuff occlusion), exercise with lower body positive pressure (LBPP) of 45 Torr, and a combination of thigh cuff occlusion and LBPP (combination). Indexes of central command (heart rate, oxygen uptake, ratings of perceived exertion, and electromyographic activity), cardiac output, stroke volume, and total peripheral resistance were not significantly different between the four conditions. Mechanical stimulation during LBPP and combination conditions resulted in significant elevations in intramuscular pressure and mean arterial pressure from control at rest and throughout the incremental exercise protocol (P < 0.05). Conversely, there existed no significant changes in mean arterial pressure when the metaboreflex was stimulated by cuff occlusion. These findings suggest that under normal conditions the mechanoreflex is tonically active and is the primary mediator of exercise pressor reflex-induced alterations in arterial blood pressure during submaximal dynamic exercise in humans.
Coltman, Celeste E; McGhee, Deirdre E; Steele, Julie R
2015-01-01
Bra straps are a primary source of discomfort during sport and exercise, particularly for women with large breasts. This study aimed to investigate the effects of altering bra strap orientation and design on bra strap comfort, pressure and breast support in women with large breasts. This is a descriptive laboratory study. Bra strap discomfort (visual analogue scale, 0 to 10), pressure (custom-designed 10 mm 2 calibrated pressure sensor, 0.5 to 24 kPa range, 50 Hz, S2011, Novel GmbH, Munich, Germany, placed under the right bra strap at the crest of each participant's shoulder), preference ranking and vertical breast displacement (VBD; Optotrak Certus® motion capture system, 200 Hz, Northern Digital, Ontario, Canada) data during dynamic treadmill running and static upright standing (pressure only) were collected for 23 active women with large breasts (D+ cup size) while they wore an encapsulation sports bra with six different bra strap conditions (two bra strap orientations: vertical and cross-back; three bra strap designs: standard width, wide and gel). Bra strap discomfort was significantly less ( p ≤ 0.001) in the vertical compared to the cross-back strap orientation, which was the most preferred orientation despite no significant difference in strap pressure. The wide strap design had the lowest discomfort scores, significantly lower strap pressure compared to the standard width and gel strap designs ( p < 0.001), and was equally the most preferred design with the gel straps. There was no significant difference in VBD among the six strap conditions. Bra straps that are vertically orientated and wide (approximately 4.5 cm in width) are preferable for women with large breasts during sport and exercise to minimise bra strap pressure and discomfort. The addition of gel pads under bra straps may also decrease discomfort and prevent straps slipping off the shoulders, although this notion warrants further investigation.
Källman, Ulrika; Engström, Maria; Bergstrand, Sara; Ek, Anna-Christina; Fredrikson, Mats; Lindberg, Lars-Göran; Lindgren, Margareta
2015-03-01
Although repositioning is considered an important intervention to prevent pressure ulcers, tissue response during loading in different lying positions has not been adequately explored. To compare the effects of different lying positions on interface pressure, skin temperature, and tissue blood flow in nursing home residents. From May 2011 to August 2012, interface pressure, skin temperature, and blood flow at three tissue depths were measured for 1 hr over the sacrum in 30° supine tilt and 0° supine positions and over the trochanter major in 30° lateral and 90° lateral positions in 25 residents aged 65 years or older. Measurement of interface pressure was accomplished using a pneumatic pressure transmitter connected to a digital manometer, skin temperature using a temperature sensor, and blood flow using photoplethysmography and laser Doppler flowmetry. Interface pressure was significantly higher in the 0° supine and 90° lateral positions than in 30° supine tilt and 30° lateral positions. The mean skin temperature increased from baseline in all positions. Blood flow was significantly higher in the 30° supine tilt position compared to the other positions. A hyperemic response in the post pressure period was seen at almost all tissue depths and positions. The 30° supine tilt position generated less interface pressure and allowed greater tissue perfusion, suggesting that this position is the most beneficial. © The Author(s) 2014.
Mann, H J; Fuhs, D W; Cerra, F B
1988-03-01
The influence of the piston-cassette pump fill stroke on the pharmacodynamic response to sodium nitroprusside was evaluated prospectively in 10 adult patients in the surgical intensive-care unit. Simultaneous analog recordings of blood pressure and fill stroke were made over three complete pump fill cycles in each patient. Sodium nitroprusside flow rates and concentrations were recorded throughout the data-collection period. Analysis was based on the maximum pressure obtained during the two-minute baseline period before a fill stroke (Pmax baseline), the pressure at the initiation of the fill stroke (P initial), and the maximum pressure obtained during the two-minute period after the fill stroke (Pmax postfill). The maximum systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) during the baseline and post-fill-stroke periods were significantly different. The mean (+/- S.D.) variability in pressure between the time periods Pmax baseline and Pmax postfill was 3.9 +/- 5.8 mm Hg for SBP (range, -8 to +16), 3.5 +/- 5.7 mm Hg for DBP (range, -7 to +13), and 3.6 +/- 5.6 mm Hg for MBP (range, -7 to +14). The likelihood of a pharmacodynamic change was inconsistent both between and within patients. Within patients the difference between cycles for the variability between time periods ranged from a minimum of 2 mm Hg to a maximum of 16 mm Hg for SBP, 2 mm Hg to 17 mm Hg for DBP, and 1 mm Hg to 17 mm Hg for MBP. The variability within the baseline period (Pmax baseline - P initial) in SBP was significantly greater than the variability between the time periods, while the differences for DBP and MBP were not significant.(ABSTRACT TRUNCATED AT 250 WORDS)
Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishibashi, Hiroyuki, E-mail: ishibash@aichi-med-u.ac.j; Ishiguchi, Tsuneo; Ohta, Takashi
2010-10-15
PurposeIntraoperative sac pressure was measured during endovascular abdominal aortic aneurysm repair (EVAR) to evaluate the clinical significance of sac pressure measurement.MethodsA microcatheter was placed in an aneurysm sac from the contralateral femoral artery, and sac pressure was measured during EVAR procedures in 47 patients. Aortic blood pressure was measured as a control by a catheter from the left brachial artery.ResultsThe systolic sac pressure index (SPI) was 0.87 {+-} 0.10 after main-body deployment, 0.63 {+-} 0.12 after leg deployment (P < 0.01), and 0.56 {+-} 0.12 after completion of the procedure (P < 0.01). Pulse pressure was 55 {+-} 21 mmHg,more » 23 {+-} 15 mmHg (P < 0.01), and 16 {+-} 12 mmHg (P < 0.01), respectively. SPI showed no significant differences between the Zenith and Excluder stent grafts (0.56 {+-} 0.13 vs. 0.54 {+-} 0.10, NS). Type I endoleak was found in seven patients (15%), and the SPI decreased from 0.62 {+-} 0.10 to 0.55 {+-} 0.10 (P = 0.10) after fixing procedures. Type II endoleak was found in 12 patients (26%) by completion angiography. The SPI showed no difference between type II endoleak positive and negative (0.58 {+-} 0.12 vs. 0.55 {+-} 0.12, NS). There were no significant differences between the final SPI of abdominal aortic aneurysms in which the diameter decreased in the follow-up and that of abdominal aortic aneurysms in which the diameter did not change (0.53 {+-} 0.12 vs. 0.57 {+-} 0.12, NS).ConclusionsSac pressure measurement was useful for instant hemodynamic evaluation of the EVAR procedure, especially in type I endoleaks. However, on the basis of this small study, the SPI cannot be used to reliably predict sac growth or regression.« less
Ziegler, M U; Reinelt, H
2018-05-01
Patients undergoing cardiac surgery need extensive and invasive monitoring, which needs to be individually adapted for each patient and requires a diligent risk-benefit analysis. The use of a pulmonary artery catheter (PAC) seems to be justifiable in certain cases; therefore, the preoperative diagnosis of pulmonary hypertension represents an indication for perioperative monitoring with PAC in the S3 guidelines of the German Society for Anesthesiology and Intensive Care Medicine (DGAI). In many cases, however, this preoperative diagnosis cannot be confirmed intraoperatively. We wanted to find out whether this is just an impression or whether there actually are significant differences between preoperative, intraoperative and postoperative pulmonary artery pressures. After obtaining ethical approval, we retrospectively compared the pulmonary pressures of cardiac surgery patients with an elevated pulmonary pressure during preoperative right heart catheterization with those obtained intraoperatively and postoperatively by means of a PAC. All patients with a preoperatively documented pulmonary artery pressure of 40 mmHg or above and an intraoperative use of a PAC during a 4-year period were included. Exclusion criteria were intracardiac shunts, cardiogenic shock, emergency procedures, pulmonary hypertension of non-cardiac origin and a time span of more than 1 year between right heart catheterization and surgery. We included 90 patients. In the whole group and in the subgroups (according to diagnosis, time elapsed between heart catheterization and operation and pulmonary pressure), there were significant differences between preoperative and intraoperative pulmonary and systemic pressures. Systemic and pulmonary artery pressures were significantly higher during preoperative catheterization than intraoperatively. The systemic systolic pressure/systolic pulmonary pressure ratio, however, remained constant. The intraoperative and postoperative systemic and pulmonary artery pressures showed no significant differences. As a normal ejection fraction does not exclude heart failure with preserved ejection fraction and as we did not have any information on this condition, we did not group the patients according to the ejection fraction. An elevated pulmonary pressure obtained preoperatively during right heart catheterization is not indicative of an elevated pulmonary pressure either intraoperatively or postoperatively. There are various explanations for the differences (e.g., different physiological and pathophysiological settings, such as sedation with potential hypercapnia versus anesthesia with vasodilation when measured; newly prescribed medication coming into effect between the right heart catheterization and surgery; intraoperative positioning). Even though the inherent risks of a PAC seem to be low, we recommend refraining from using a PAC in patients with a once documented elevated pulmonary pressure by default. As an alternative we suggest estimating the pulmonary pressure by transesophageal echocardiography (TEE) as an aid to decide whether the patient will benefit from the use of a PAC. Especially if it is not possible to identify tricuspid valve regurgitation for determining the peak gradient, it is helpful to check for additional signs of pulmonary hypertension. But we also have to bear in mind that in the postoperative period only a PAC can provide continuous measurement of pulmonary pressure.
Kim, Won Young; Jun, Jong Hun; Huh, Jin Won; Hong, Sang Bum; Lim, Chae-Man; Koh, Younsuck
2013-12-01
The accuracy of arterial blood pressure (ABP) monitoring is crucial in treating septic shock patients. Clinically significant differences in central to peripheral ABP could develop into sepsis during vasopressor therapy. The aim of this study was to investigate the difference between radial (peripheral) and femoral (central) ABP in septic shock patients receiving high-dose norepinephrine (NE) therapy. This prospective observational study comparing simultaneous intra-arterial measurements of radial and femoral ABP was performed at a university-affiliated, tertiary referral center between October 2008 and March 2009. Patients with septic shock who needed continuous blood pressure monitoring and high-dose NE therapy 0.1 µg/kg per minute or greater to maintain mean arterial pressure (MAP) of 65 mmHg or greater were included. Statistical analysis was conducted using the Bland-Altman method for comparison of repeated measures. In total, 250 sets of systolic, mean, and diastolic femoral and radial ABP were recorded at baseline and after NE titration. Arterial blood pressure readings from the radial artery were underestimated compared with those from the femoral artery. Overall bias (mean difference between simultaneous measurements) between radial and femoral MAP was +4.9 mmHg; however, during high-dose NE therapy, the bias increased to +6.2 mmHg (95% limits of agreement: -6.0 to +18.3 mmHg). Clinically significant radial-femoral MAP differences (MAP ≥5 mmHg) occurred in up to 62.2% of patients with high-dose NE therapy. Radial artery pressure frequently underestimates central pressure in septic shock patients receiving high-dose NE therapy. Femoral arterial pressure monitoring may be more appropriate when high-dose NE therapy is administered.
Soanker, Radhika; Naidu, M U R; Raju, Sree Bhushan; Prasad, A Krishna; Rao, T Ramesh Kumar
2012-05-01
Blood pressure (BP) reduction is the major determinant of benefit provided by antihypertensive treatment. Although different drugs reduce peripheral BP to some extent, there may be a significant difference in their effect on central BP reduction. It has been shown that beta-blockers are efficient in reducing peripheral, but not central BP. This study was done to assess the effect of beta-1-blocker, nebivolol, in patients with essential hypertension on central aortic pressures and arterial stiffness. In this single arm, open-labeled study, 13 patients were given nebivolol, 5 mg orally once daily for 15 days. Primary outcome was change in central aortic pressure, and other measures of efficacy included changes in brachial BP, augmentation index (AIx%), AIx%@75 HR, augmentation pressure (AP), heart rate (HR), and carotid femoral pulse wave velocity (PWVcf). Nebivolol 5 mg significantly reduced central aortic pressures [systolic BP, 131.5-111.6 mmHg; diastolic BP, 96.3-81.7 mmHg; Mean Arterial Pressure (MAP), 111.3-94.0 mmHg (all P<0.0001), and Pulse Pressure (PP), 35.2-29.7 mmHg (P<0.01)]. AIx%@75 HR reduced from 29 to 21.6 (P<0.001) and PWVcf reduced from 8.6 to 7.2 m/s (P<0.001). One subject was lost to followup. Nebivolol 5 mg demonstrated antihypertensive efficacy in patients with essential hypertension by reducing not only peripheral brachial pressures, but also significantly reducing central aortic pressures, augmentation index, and carotid femoral pulse wave velocity, which is the marker of arterial stiffness.
Shoar, Saeed; Naderan, Mohammad; Ebrahimpour, Hossein; Soroush, Ahmadreza; Nasiri, Shirzad; Movafegh, Ali; Khorgami, Zhamak
2016-04-01
Laparoscopic cholecystectomy (LC) has become the gold-standard treatment for gallstone diseases. However, despite huge reduction in operative injury, systemic stress response remains high. This randomized controlled trial (RCT) aimed to compare systemic stress response between 2 different techniques of CO2 pneumoperitoneum. Trough a prospective, double-blinded RCT, serum levels of cortisol, adrenaline, glucose, and C-reactive protein (CRP) were compared between the two groups consisted of 50 patients undergoing LC under low-pressure and standard-pressure CO2 pneimoperitoneum. A total of fifty patients undergoing LC were equally assigned to 2 groups of twenty five patients. Average age was 48 ± 13.8 years (range, 19-74 years). Operative time was similar between standard-pressure group (47.8 ± 16.8 min) and low-pressure group (53.6 ± 25.1). Moreover, intra-operative IV volume administration and urine output did not differ significantly between the 2 groups (p > 0.05). Although the average heart rate and mean arterial pressure were slightly higher in a standard-pressure group compared with a low-pressure group, serial measurements of these parameters were statistically similar between the 2 groups. Serial changes of serum levels of cortisol, glucose, adrenaline, and CRP were compared between surgery day, postoperative 6-h and 1st postoperative day, which did not differ significantly between the standard-pressure and the low-pressure groups (p > 0.05). Our study did not reveal any alteration in systemic stress response with reduction in intra-abdominal pressure of pneumoperitoneum in LC. RCT REGISTRATION: irct.ir ID: IRCT201110072982N5. Copyright © 2016 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
Tourah, Anita; Moshaverinia, Alireza; Chee, Winston W
2014-02-01
Surface roughness and irregularities are important properties of dental investment materials that can affect the fit of a restoration. Whether setting under air pressure affects the surface irregularities of gypsum-bonded and phosphate-bonded investment materials is unknown. The purpose of this study was to investigate the effect of air pressure on the pore size and surface irregularities of investment materials immediately after pouring. Three dental investments, 1 gypsum-bonded investment and 2 phosphate-bonded investments, were investigated. They were vacuum mixed according to the manufacturers' recommendations, then poured into a ringless casting system. The prepared specimens were divided into 2 groups: 1 bench setting and the other placed in a pressure pot at 172 kPa. After 45 minutes of setting, the rings were removed and the investments were cut at a right angle to the long axis with a diamond disk. The surfaces of the investments were steam cleaned, dried with an air spray, and observed with a stereomicroscope. A profilometer was used to evaluate the surface roughness (μm) of the castings. The number of surface pores was counted for 8 specimens from each group and the means and standard deviations were reported. Two-way ANOVA was used to compare the data. Specimens that set under atmospheric air pressure had a significantly higher number of pores than specimens that set under increased pressure (P<.05). No statistically significant differences for surface roughness were found (P=.078). Also, no significant difference was observed among the 3 different types of materials tested (P>.05). Specimens set under positive pressure in a pressure chamber presented fewer surface bubbles than specimens set under atmospheric pressure. Positive pressure is effective and, therefore, is recommended for both gypsum-bonded and phosphate-bonded investment materials. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Kakio, Yuki; Uchida, Haruhito A; Umebayashi, Ryoko; Takeuchi, Hidemi; Okuyama, Yuka; Hanayama, Yoshihisa; Wada, Jun
2017-04-01
Olmesartan and azilsartan, angiotensin II receptor blockers (ARBs), are expected to decrease blood pressure more than the other ARBs. We conducted randomized-controlled trials to compare the practical efficacy of olmesartan with azilsartan. Eighty-four patients treated with the conventional ARBs for more than 3 months were assigned randomly to receive either 20 mg of olmesartan (olmesartan medoxomil, OL group) or 20 mg of azilsartan (azilsartan, not azilsartan medoxomil, AZ group) once daily for 16 weeks. The practical efficacy on blood pressure was compared between the OL and AZ groups. Office blood pressure of both groups decreased significantly (OL group: 152/86-141/79 mmHg, P<0.05, AZ group: 149/83-135/75 mmHg; P<0.05). Diastolic home blood pressure in the AZ group decreased significantly (79±9-74±7 mmHg; P<0.05), but not in the OL group (79±11-75±10 mmHg; P=0.068). However, there were no significant differences between the groups. The dosage of olmesartan and azilsartan increased significantly and slightly for 16 weeks (OL group: 20.3-23.1 mg; P<0.05, AZ group: 20.5-23.2 mg; P<0.05), without a significant difference between groups. Furthermore, there were no significant differences in renal function, lipid profiles, brain natriuretic peptide, soluble fms-like tyrosine kinase-1, and urinary L-type fatty acid-binding protein between the two groups. Both olmesartan and azilsartan equally reduced blood pressures. Both olmesartan and azilsartan showed a renoprotective effect and were well tolerated without any major adverse events.
Association between intraabdominal pressure during gynaecologic laparoscopy and postoperative pain.
Kundu, Sudip; Weiss, Clara; Hertel, Hermann; Hillemanns, Peter; Klapdor, Rüdiger; Soergel, Philipp
2017-05-01
Laparoscopy is nowadays a well-established surgical method and plays a main role in an ever-increasing range of indications in gynaecology. High-quality studies of surgical techniques are necessary to improve the quality of patient care. The present study aims at evaluating postoperative pain after gynaecological laparoscopy depending on the intraoperative CO 2 pressure. In a prospective, monocentric, randomized single-blind study at the Department of Gynaecology and Obstetrics at the Hannover Medical School, we include patients scheduled for different laparoscopic procedures. Randomization of the intraoperative CO 2 pressure was carried out in six groups. Pain was assessed the day after surgery by the blinded nurse using a visual analogue scale. 550 patients were included in the period from May 2013 to January 2016. The analysis of the per protocol population PPP (n = 360) showed no statistically significant difference between the six intervention groups with regard to mean postoperative pain perception. In direct comparison between two groups, an intraoperative CO 2 pressure of 15 mmHg was associated with a significant higher pain score than a pressure of 12 mmHg. The difference was 7.46 mm on a 10 cm VAS. The results of our study indicate that a CO 2 pressure of 12 versus 15 mmHg can be advantageous. However, the clinical relevance remains unclear due to the low difference in pain. The additional benefit of an even lower pressure of 10 or 8 mmHg cannot be reliably assessed; we found signs of poor visibility conditions in these low pressure groups.
Derby, Richard; Lee, Sang Hoon; Lee, Jeong-Eun; Lee, Sang-Heon
2011-01-01
The study compares the rate of positive discograms using an automated versus a manual pressure-controlled injection devise and compares the pressure and volume values at various pressures and initial evoked pain and 6/10 or greater evoked pain. A retrospective study prospectively collected patient study data used in a prior prospective study and with prospectively collected data which is routinely collected per our institutional standardized audit protocol. Two custom-built disc manometers (automated injection speed control; manual injection speed control) were sequentially employed during provocation discography in 510 discs of 151 consecutive patients. Two hundred thirty-seven discs of 67 patients with chronic low back pain were evaluated using the automated manometer (automated group) and 273 discs of 84 patients were evaluated with a manual manometer (manual group). No significant differences in positive discogram rates were found between the automated and manual groups (32.1% vs 32.6% per disc, respectively, P>0.05). No significant differences in low-pressure positive discogram rates were found (16.0% vs 15.0% per disc, automated group versus manual group, respectively, P>0.05). However, there were significantly increased volumes and lower pressures at initial and "bad" pain provocation. The study results found equivalent positive discogram rates following a series of pressure-controlled discography using either an automated or manual pressure devise. There were, however significant increases in volume at both initial onset of evoked pain and at 6/10 pain when using the automated injection devise that may have caused the observed lower opening pressure and lower pressure values at initial evoked pain. Assuming increased volumes are innocuous, automated injection is inherently more controlled and may better reduce unintended and often unrecorded spurious high dynamic pressure peaks thereby reducing conscious and unconscious operator bias. Wiley Periodicals, Inc.
Racial differences in barriers to blood pressure control in a family practice setting.
Scott, Jonathan M; Spees, Colleen K; Taylor, Christopher A; Wexler, Randy
2010-10-01
Hypertension prevalence in the African American community is greater than in all other ethnic groups. Cultural perceptions of health and disease introduce barriers to providing effective care. The purpose of this study was to identify racial differences in the perceived causes of hypertension, current behaviors performed to control blood pressure, and perceived barriers to preventing or treating hypertension. A self-administered survey of patients seen for medical care in a primary care network was conducted. The survey was developed to measure perceptions of hypertension etiology and treatments. Data from African American (n = 69) and Caucasian (n = 218) respondents were used to assess racial differences in perceptions of blood pressure control. About half of respondents knew their current blood pressures. African American patients were significantly less likely to believe that hypertension was caused by a lack of exercise and obesity. Significantly more Caucasians were less likely to report cutting down on table salt and taking prescription medications for blood pressure control. Both African Americans and Caucasians believed that sodium reduction was the most easily changed behavior to control their blood pressure, while both groups identified weight loss as being the most difficult. Racial differences exist in the perceived causes and treatments of high blood pressure, indicating a need for further patient education. When treating and counseling patients, physicians and support staff members must be sensitive to racial diversity and strive to offer culturally relevant solutions, especially for behaviors perceived as most difficult to change.
Guelrud, M; Mendoza, S; Vicent, S; Gomez, M; Villalta, B
1983-02-01
To determine the significance of manometric pressure, measurements of the sphincter of Oddi in a control group and in patients with cholelithiasis with common duct stones with and without recurrent pancreatitis were studied. Sphincter of Oddi pressure was recorded continuously and by station pull-through by a triple lumen catheter. The basal sphincter of Oddi pressure, the mean pressure gradient between common duct and duodenum, and the sphincter of Oddi wave amplitude were measured. There was no significant difference between control subjects and patients with gallstones and common duct stones. In patients with common duct stones and recurrent pancreatitis the basal sphincter of Oddi pressure, the pressure gradient between common duct and duodenum, and the wave amplitude were significantly increased over control patients. These studies suggest that abnormalities in the sphincter of Oddi motor function are more common in patients with common duct stones with recurrent pancreatitis than in similar patients without pancreatitis.
Improvement of Diurnal Blood Pressure Variation by Azilsartan.
Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori
2018-01-01
Azilsartan is an angiotensin II receptor blocker with a potent antihypertensive effect. In a multicenter, prospective, open-label study, 265 patients with poor blood pressure control despite treatment with other angiotensin II receptor blockers were switched to 20 mg/day of azilsartan (patients on standard dosages) or 40 mg/day of azilsartan (patients on high dosages). Blood pressure was 149/83 mm Hg before switching and was significantly reduced from 1 month after switching until final assessment (132/76 mm Hg, P < 0.001). The pulse rate was 72/min before switching and increased significantly from 3 months after switching until final assessment (74/min, P < 0.005). A significant decrease of home morning systolic and diastolic pressure was observed from 1 and 3 months, respectively. Home morning blood pressure was 143/82 mm Hg before switching and 130/76 mm Hg at final assessment (P < 0.01). The morning-evening difference of systolic blood pressure decreased from 14.6 to 6.6 mm Hg after switching (P = 0.09). The estimated glomerular filtration rate was significantly decreased at 3, 6, and 12 months after switching, and serum uric acid was significantly increased at 12 months. No serious adverse events occurred. Azilsartan significantly reduced the blood pressure and decreased diurnal variation in patients responding poorly to other angiotensin II receptor blockers.
Qian, J; Yu, S S; Liu, J J; Chen, L; Jing, J H
2018-04-03
Objective: To analyze the biomechanics changes of lumbar spine caused by foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy using the finite element method. Methods: Three healthy adult males (aged 35.6 to 42.3 years) without spinal diseases were enrolled in this study and 3D-CT scans were carried out to obtain the parameters of lumbar spine. Mimics software was applied to build a 3D finite element model of lumbar spine. Graded resections (1/4, 2/4, 3/4 and 4/4) of the left superior articular process of L(5) were done via percutaneous transforaminal endoscopic lumbar discectomy. Then, the pressure of the L(4/5) right facets, the pressure of the L(4/5) intervertebral disc and the motion of lumbar spine were recorded after simulating the normal flexion and extension, lateral flexion and rotation of the lumbar spine model during different resections. The data were compared among groups with analysis of variance. Results: Comparing with the normal group, after 1/4 resection of the left superior articular process of L(5), the pressure of the L(4/5) right facets showed significant differences during left lateral flexion and rotation of lumbar spine ( q =8.823, 8.248, both P <0.05); and the pressure of L(4/5) intervertebral disc also changed significantly during extension and right rotation of lumbar spine ( q =6.918, 6.438, both P <0.05); the motion of lumbar spine showed obvious differences during right lateral flexion and rotation ( q =6.845, 7.772, 13.58, all P <0.05). Comparing with the normal group, after 2/4 resection of the left superior articular process of L(5), the pressure of the L(4/5) right facets presented significant differences during all conditions ( q =5.670-17.830, all P <0.05); the pressure of L(4/5) intervertebral disc changed significantly during flexion, extension, lateral flexion and right rotation ( q =5.260, 17.150, 5.727, 8.890, 15.660, all P <0.05); the motion of lumbar spine also existed differences during extension, lateral flexion and rotation ( q =9.106, 5.431, 12.060, 11.160, 17.260, all P <0.05). However, after 3/4 resections, the pressure of the L(4/5) right facets, the pressure of the L(4/5) intervertebral disc and the motion of lumbar spine presented differences during all conditions when compared with those in normal group ( q =6.303-25.48, all P <0.05). After 4/4 resections, the pressure of the L(4/5) right facets and the pressure of the L(4/5) intervertebral disc and the motion of lumbar spine showed significant differences during all conditions when compared with those in normal group ( q =8.065-45.70, all P <0.05). Conclusions: The biomechanics and the stability of lumbar spine changed partly after 1/4 resection of the superior articular process and obviously after more than 2/4 is resected. The superior articular process should be paid more attention during foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garner, Rochelle E., E-mail: rochelle.garner@canad
Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models weremore » used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure and hypertension. However, the significance and direction of this association differs by sex, smoking status, and body mass index category. - Highlights: • Blood and urinary cadmium levels higher among those with hypertension. • Evidence of association between cadmium levels, blood pressure and hypertension. • Significance and direction of association differs by sex, smoking status, and BMI. • Higher urinary cadmium levels lower hypertension risk for current (female) smokers.« less
Zverev, Yury
2016-08-01
In a recent paper, Mayolas Pi, Arrese, Aparicio, and Masià reported the absence of significant bilateral differences between legs in the average plantar pressure during walking in six- to seven-year-old children. However, the authors demonstrated bilateral differences in the distribution of plantar pressure during walking independent of foot preference in three tests: kicking a ball with precision, balancing on one foot, and jumping on one foot. From the results, Mayolas Pi et al. proposed that this asymmetric pattern of plantar pressure distribution is not caused by laterality. This paper suggests that the selected age range of participants and methods of diagnosing of laterality and data analysis could have significant effects on the results. Indeed, according to the literature, laterality in humans is a multidimensional trait with poor stabilization and conformity between different dimensions in preschool and younger school children. © The Author(s) 2016.
Holmgaard, Frederik; Vedel, Anne G; Ravn, Hanne Berg; Nilsson, Jens C; Rasmussen, Lars S
2018-05-13
In this substudy of a randomised, clinical trial, we explored the sublingual microcirculation during cardiac surgery at two different levels of blood pressure. We hypothesised that a higher mean arterial pressure during cardiopulmonary bypass would cause higher Microvascular Flow Index. Thirty-six cardiac surgery patients undergoing coronary artery bypass grafting were included and randomised to either low (40-50 mmHg) or high (70-80 mmHg) mean arterial pressure during cardiopulmonary bypass. Sidestream Dark Field video images were recorded from the sublingual mucosa. Recordings were analysed in a blinded fashion to quantify microcirculatory variables. Mean arterial pressure during cardiopulmonary bypass in the low target group was 45.0 mmHg (SD 5.3) vs. 67.2 mmHg (SD 8.9) in the high target group. We found no significant difference between the two groups in Microvascular Flow Index during cardiopulmonary bypass evaluated for all vessels: 2.91 vs. 2.90 (p = 0.82). For small vessels (< 20 micrometers), the corresponding values were 2.87 and 2.85 in the low and high target groups, respectively (p = 0.82). We found no significant difference in sublingual microcirculatory flow expressed as Microvascular Flow Index according to two different levels of mean arterial pressure during cardiopulmonary bypass. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Godwin, Marshall; Dawes, Martin; Kiss, Alexander; Tobe, Sheldon W; Grant, F Curry; Kaczorowski, Janusz
2011-01-01
Objective To compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard. Design Multi-site cluster randomised controlled trial. Setting Primary care practices in five cities in eastern Canada. Participants 555 patients with systolic hypertension and no serious comorbidities under the care of 88 primary care physicians in 67 practices in the community. Interventions Practices were randomly allocated to either ongoing use of manual office blood pressure (control group) or automated office blood pressure (intervention group) using the BpTRU device. The last routine manual office blood pressure (mm Hg) was obtained from each patient’s medical record before enrolment. Office blood pressure readings were compared before and after enrolment in the intervention and control groups; all readings were also compared with the awake ambulatory blood pressure. Main outcome measure Difference in systolic blood pressure between awake ambulatory blood pressure minus automated office blood pressure and awake ambulatory blood pressure minus manual office blood pressure. Results Cluster randomisation allocated 31 practices (252 patients) to manual office blood pressure and 36 practices (303 patients) to automated office blood pressure measurement. The most recent routine manual office blood pressure (149.5 (SD 10.8)/81.4 (8.3)) was higher than automated office blood pressure (135.6 (17.3)/77.7 (10.9)) (P<0.001). In the control group, routine manual office blood pressure before enrolment (149.9 (10.7)/81.8 (8.5)) was reduced to 141.4 (14.6)/80.2 (9.5) after enrolment (P<0.001/P=0.01), but the reduction in the intervention group from manual office to automated office blood pressure was significantly greater (P<0.001/P=0.02). On the first study visit after enrolment, the estimated mean difference for the intervention group between the awake ambulatory systolic/diastolic blood pressure and automated office blood pressure (−2.3 (95% confidence interval −0.31 to −4.3)/−3.3 (−2.7 to −4.4)) was less (P=0.006/P=0.26) than the difference in the control group between the awake ambulatory blood pressure and the manual office blood pressure (−6.5 (−4.3 to −8.6)/−4.3 (−2.9 to −5.8)). Systolic/diastolic automated office blood pressure showed a stronger (P<0.001) within group correlation (r=0.34/r=0.56) with awake ambulatory blood pressure after enrolment compared with manual office blood pressure versus awake ambulatory blood pressure before enrolment (r=0.10/r= 0.40); the mean difference in r was 0.24 (0.12 to 0.36)/0.16 (0.07 to 0.25)). The between group correlation comparing diastolic automated office blood pressure and awake ambulatory blood pressure (r=0.56) was stronger (P<0.001) than that for manual office blood pressure versus awake ambulatory blood pressure (r=0.30); the mean difference in r was 0.26 (0.09 to 0.41). Digit preference with readings ending in zero was substantially reduced by use of automated office blood pressure. Conclusion In compliant, otherwise healthy, primary care patients with systolic hypertension, introduction of automated office blood pressure into routine primary care significantly reduced the white coat response compared with the ongoing use of manual office blood pressure measurement. The quality and accuracy of automated office blood pressure in relation to the awake ambulatory blood pressure was also significantly better when compared with manual office blood pressure. Trial registration Clinical trials NCT 00214053. PMID:21300709
An Analysis of the Impact of Valve Closure Time on the Course of Water Hammer
NASA Astrophysics Data System (ADS)
Kodura, Apoloniusz
2016-06-01
The knowledge of transient flow in pressure pipelines is very important for the designing and describing of pressure networks. The water hammer is the most common example of transient flow in pressure pipelines. During this phenomenon, the transformation of kinetic energy into pressure energy causes significant changes in pressure, which can lead to serious problems in the management of pressure networks. The phenomenon is very complex, and a large number of different factors influence its course. In the case of a water hammer caused by valve closing, the characteristic of gate closure is one of the most important factors. However, this factor is rarely investigated. In this paper, the results of physical experiments with water hammer in steel and PE pipelines are described and analyzed. For each water hammer, characteristics of pressure change and valve closing were recorded. The measurements were compared with the results of calculations perfomed by common methods used by engineers - Michaud's equation and Wood and Jones's method. The comparison revealed very significant differences between the results of calculations and the results of experiments. In addition, it was shown that, the characteristic of butterfly valve closure has a significant influence on water hammer, which should be taken into account in analyzing this phenomenon. Comparison of the results of experiments with the results of calculations? may lead to new, improved calculation methods and to new methods to describe transient flow.
Residual Negative Pressure in Vacuum Tubes Might Increase the Risk of Spurious Hemolysis.
Xiao, Tong-Tong; Zhang, Qiao-Xin; Hu, Jing; Ouyang, Hui-Zhen; Cai, Ying-Mu
2017-05-01
We planned a study to establish whether spurious hemolysis may occur when negative pressure remains in vacuum tubes. Four tubes with different vacuum levels (-54, -65, -74, and -86 kPa) were used to examine blood drawn from one healthy volunteer; the tubes were allowed to stand for different times (1, 2, 3, and 4 hours). The plasma was separated and immediately tested for free hemoglobin (FHb). Thirty patients were enrolled in a verification experiment. The degree of hemolysis observed was greater when the remaining negative pressure was higher. Significant differences were recorded in the verification experiment. The results suggest that residual negative pressure might increase the risk of spurious hemolysis.
Nutrient Intake, Physical Activity, and CVD Risk Factors in Children
Day, R. Sue; Fulton, Janet E.; Dai, Shifan; Mihalopoulos, Nicole L.; Barradas, Danielle T.
2009-01-01
Background Associations among dietary intake, physical activity, and cardiovascular disease (CVD) risk factors are inconsistent among male and female youth, possibly from lack of adjustment for pubertal status. The purpose of this report is to describe the associations of CVD risk factors among youth, adjusted for sexual maturation. Methods Data analyzed in 2007 from a sumsample of 556 children aged 8, 11, and 14 years in Project HeartBeat!, 1991–1993, provide cross-sectional patterns of CVD risk factors by age and gender, adjusting for sexual maturation, within dietary fat and physical activity categories. Results Girls consuming moderate- to high-fat diets were significantly less physically active than those consuming low-fat diets. Boys and girls consuming high-fat diets had higher saturated fat and cholesterol intakes than children in low-fat categories. Boys had no significant differences in physical activity, blood pressure, waist circumference, or plasma cholesterol levels across fat categories. Girls’ plasma cholesterol levels showed no significant differences across fat categories. Dietary intake did not differ across moderate-to-vigorous physical activity (MVPA) categories within gender. There were no differences in BMI by fat or MVPA categories for either gender. Girls’ waist circumference differed significantly by fat category, and systolic blood pressure differed significantly across fat and MVPA categories. Boys’ fifth-phase diastolic blood pressure was significantly different across MVPA categories. Conclusions Girls consuming atherogenic diets were significantly less physically active than those with low fat intakes, whereas boys consuming high-fat diets did not show differences in physical activity measures. With the prevalence of overweight rising among youth, the impact of atherogenic diets and sedentary lifestyles on CVD risk factors is of concern to public health professionals. PMID:19524152
Fernando, Malindu E; Crowther, Robert G; Lazzarini, Peter A; Sangla, Kunwarjit S; Wearing, Scott; Buttner, Petra; Golledge, Jonathan
2016-09-15
Current international guidelines advocate achieving at least a 30 % reduction in maximum plantar pressure to reduce the risk of foot ulcers in people with diabetes. However, whether plantar pressures differ in cases with foot ulcers to controls without ulcers is not clear. The aim of this study was to assess if plantar pressures were higher in patients with active plantar diabetic foot ulcers (cases) compared to patients with diabetes without a foot ulcer history (diabetes controls) and people without diabetes or a foot ulcer history (healthy controls). Twenty-one cases with diabetic foot ulcers, 69 diabetes controls and 56 healthy controls were recruited for this case-control study. Plantar pressures at ten sites on both feet and stance phase duration were measured using a pre-established protocol. Primary outcomes were mean peak plantar pressure, pressure-time integral and stance phase duration. Non-parametric analyses were used with Holm's correction to correct for multiple testing. Binary logistic regression models were used to adjust outcomes for age, sex and body mass index. Median differences with 95 % confidence intervals and Cohen's d values (standardised mean difference) were reported for all significant outcomes. The majority of ulcers were located on the plantar surface of the hallux and toes. When adjusted for age, sex and body mass index, the mean peak plantar pressure and pressure-time integral of toes and the mid-foot were significantly higher in cases compared to diabetes and healthy controls (p < 0.05). The stance phase duration was also significantly higher in cases compared to both control groups (p < 0.05). The main limitations of the study were the small number of cases studied and the inability to adjust analyses for multiple factors. This study shows that plantar pressures are higher in cases with active diabetic foot ulcers despite having a longer stance phase duration which would be expected to lower plantar pressure. Whether plantar pressure changes can predict ulcer healing should be the focus of future research. These results highlight the importance of offloading feet during active ulceration in addition to before ulceration.
Effects of guar gum ingestion on postprandial blood pressure in older adults.
Jang, A L; Hwang, S K; Kim, D U
2015-03-01
The aim of this study was to investigate the effects of guar gum on postprandial blood pressure in older people. A randomized, double-blind, placebo-controlled, cross-over design. Community senior centers in B city, South Korea. Twenty-two older female adults aged 67 to 88 with postprandial hypotension. The participants were randomly assigned to guar gum (semi-fluid food with 9 gram) or placebo intervention during the first treatment phase. After a washout period of 1 week, the two interventions were switched to the other in the second treatment phase. Blood pressure was measured during both phases before having a meal and every 15 minutes during 120 minutes after a meal with automated sphygmomanometer. Change in systolic blood pressure (SBP) over time was significantly different between guar gum and placebo groups (F=4.07, p=0.001). Compared with placebo group, guar gum group had significantly low prevalence of postprandial hypotension (PPH) (guar gum group=18.2% vs. placebo group=72.7%; χ² =13.20, p<0.001). It also had significant difference in change of diastolic blood pressure (DBP) over time between guar gum and placebo groups (F=2.49, p=0.027). This findings show that guar gum could be effective on postprandial drops in blood pressure in older female adults.
Harding, Seeromanie; Whitrow, Melissa; Lenguerrand, Erik; Maynard, Maria; Teyhan, Alison; Cruickshank, J Kennedy; Der, Geoff
2010-04-01
The cause of ethnic differences in cardiovascular disease remains a scientific challenge. Blood pressure tracks from late childhood to adulthood. We examined ethnic differences in changes in blood pressure between early and late adolescence in the United Kingdom. Longitudinal measures of blood pressure, height, weight, leg length, smoking, and socioeconomic circumstances were obtained from London, United Kingdom, schoolchildren of White British (n=692), Black Caribbean (n=670), Black African (n=772), Indian (n=384), and Pakistani and Bangladeshi (n=402) ethnicity at 11 to 13 years and 14 to 16 years. Predicted age- and ethnic-specific means of blood pressure, adjusted for anthropometry and social exposures, were derived using mixed models. Among boys, systolic blood pressure did not differ by ethnicity at 12 years, but the greater increase among Black Africans than Whites led to higher systolic blood pressure at 16 years (+2.9 mm Hg). Among girls, ethnic differences in mean systolic blood pressure were not significant at any age, but while systolic blood pressure hardly changed with age among White girls, it increased among Black Caribbeans and Black Africans. Ethnic differences in diastolic blood pressure were more marked than those for systolic blood pressure. Body mass index, height, and leg length were independent predictors of blood pressure, with few ethnic-specific effects. Socioeconomic disadvantage had a disproportionate effect on blood pressure for girls in minority groups. The findings suggest that ethnic divergences in blood pressure begin in adolescence and are particularly striking for boys. They signal the need for early prevention of adverse cardiovascular disease risks in later life.
Pleural manometry-historical background, rationale for use and methods of measurement.
Zielinska-Krawczyk, Monika; Krenke, Rafal; Grabczak, Elzbieta M; Light, Richard W
2018-03-01
Subatmospheric pleural pressure (Ppl), which is approximately -3 to -5 cmH 2 O at functional residual capacity (FRC) makes pleura a unique organ in the human body. The negative Ppl is critical for maintaining the lungs in a properly inflated state and for proper blood circulation within the thorax. Significant and sudden pleural pressure changes associated with major pleural pathologies, as well as therapeutic interventions may be associated with life-threatening complications. The pleural pressure may show two different values depending on the measurement method applied. These are called pleural liquid pressure and pleural surface pressure. It should also be realized that there are significant differences in pleural pressure distribution in pneumothorax and pleural effusion. In pneumothorax, the pressure is the same throughout the pleural space, while in pleural effusion there is a vertical gradient of approximately 1 cm H 2 O/cm in the pleural pressure associated with the hydrostatic pressure of the fluid column. Currently, two main methods of pleural pressure measurement are used: simple water manometers and electronic systems. The water manometers are conceptually simple, cheap and user-friendly but they only allow the estimation of the mean values of pleural pressure. The electronic systems for pleural pressure measurement are based on pressure transducers. Their major advantages include precise measurements of instantaneous pleural pressure and the ability to display and to store a large amount of data. The paper presents principles and details of pleural pressure measurement as well as the rationale for its use. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sanderson, D J; Hennig, E M; Black, A H
2000-03-01
The aim of this study was to determine the response of cyclists to manipulations of cadence and power output in terms of force application and plantar pressure distribution. Two groups of cyclists, 17 recreational and 12 competitive, rode at three nominal cadences (60, 80, 100 rev x min(-1)) and four power outputs (100, 200, 300, 400 W) while simultaneous force and in-shoe pressure data were collected. Two piezoelectric triaxial force transducers mounted in the right pedal measured components of the pedal force and orientation, and a discrete transducer system with 12 transducers recorded the in-shoe pressures. Force application was characterized by calculating peak resultant and peak effective pedal forces and positive and negative impulses. In-shoe pressures were analysed as peak pressures and as the percent relative load. The force data showed no significant group effect but there was a cadence and power main effect. The impulse data showed a significant three-way interaction. Increased cadence resulted in a decreased positive impulse, while increased power output resulted in an increased impulse. The competitive group produced less positive impulse but the difference became less at higher cadences. Few between-group differences were found in pressure, notable only in the pressure under the first metatarsal region. This showed a consistent pattern of in-shoe pressure distribution, where the primary loading structures were the first metatarsal and hallux. There was no indication that pressure at specific sites influenced the pedal force application. The absence of group differences indicated that pressure distribution was not the result of training, but reflected the intrinsic relationship between the foot, the shoe and the pedal.
Dynamics of bacteriophage genome ejection in vitro and in vivo
NASA Astrophysics Data System (ADS)
Panja, Debabrata; Molineux, Ian J.
2010-12-01
Bacteriophages, phages for short, are viruses of bacteria. The majority of phages contain a double-stranded DNA genome packaged in a capsid at a density of ~500 mg ml-1. This high density requires substantial compression of the normal B-form helix, leading to the conjecture that DNA in mature phage virions is under significant pressure, and that pressure is used to eject the DNA during infection. A large number of theoretical, computer simulation and in vitro experimental studies surrounding this conjecture have revealed many—though often isolated and/or contradictory—aspects of packaged DNA. This prompts us to present a unified view of the statistical physics and thermodynamics of DNA packaged in phage capsids. We argue that the DNA in a mature phage is in a (meta)stable state, wherein electrostatic self-repulsion is balanced by curvature stress due to confinement in the capsid. We show that in addition to the osmotic pressure associated with the packaged DNA and its counterions, there are four different pressures within the capsid: pressure on the DNA, hydrostatic pressure, the pressure experienced by the capsid and the pressure associated with the chemical potential of DNA ejection. Significantly, we analyze the mechanism of force transmission in the packaged DNA and demonstrate that the pressure on DNA is not important for ejection. We derive equations showing a strong hydrostatic pressure difference across the capsid shell. We propose that when a phage is triggered to eject by interaction with its receptor in vitro, the (thermodynamic) incentive of water molecules to enter the phage capsid flushes the DNA out of the capsid. In vivo, the difference between the osmotic pressures in the bacterial cell cytoplasm and the culture medium similarly results in a water flow that drags the DNA out of the capsid and into the bacterial cell.
A novel paradigm to evaluate conditioned pain modulation in fibromyalgia.
Schoen, Cynthia J; Ablin, Jacob N; Ichesco, Eric; Bhavsar, Rupal J; Kochlefl, Laura; Harris, Richard E; Clauw, Daniel J; Gracely, Richard H; Harte, Steven E
2016-01-01
Application of noxious stimulation to one body area reduces pain sensitivity in a remote body area through activation of an endogenous pain-inhibitory network, a behavioral phenomenon referred to as conditioned pain modulation (CPM). The efficiency of CPM is predictive of a variety of health outcomes, while impaired CPM has been associated with various chronic pain conditions. Current methods used to assess CPM vary widely, and interest in CPM method development remains strong. Here, we evaluated a novel method for assessing CPM in healthy controls and fibromyalgia (FM) patients using thumb pressure as both a test and conditioning stimulus. Sixteen female FM patients and 14 matched healthy controls underwent CPM testing with thumbnail pressure as the test stimulus, and either cold water or noxious pressure as the conditioning stimulus. CPM magnitude was evaluated as the difference in pain rating of the test stimulus applied before and during the conditioning stimulus. In healthy controls, application of either pressure or cold water conditioning stimulation induced CPM as evidenced by a significant reduction in test stimulus pain rating during conditioning ( P =0.007 and P =0.021, respectively). In contrast, in FM patients, neither conditioning stimulus induced a significant CPM effect ( P >0.274). There was a significant difference in CPM magnitude for FM patients compared to healthy controls with noxious pressure conditioning stimulation ( P =0.023); however, no significant difference in CPM was found between groups using cold water as a conditioning stimulus ( P =0.269). The current study demonstrates that thumbnail pressure can be used as both a test and conditioning stimulus in the assessment of CPM. This study further confirms previous findings of attenuated CPM in FM patients compared with healthy controls.
A novel paradigm to evaluate conditioned pain modulation in fibromyalgia
Schoen, Cynthia J; Ablin, Jacob N; Ichesco, Eric; Bhavsar, Rupal J; Kochlefl, Laura; Harris, Richard E; Clauw, Daniel J; Gracely, Richard H; Harte, Steven E
2016-01-01
Introduction Application of noxious stimulation to one body area reduces pain sensitivity in a remote body area through activation of an endogenous pain-inhibitory network, a behavioral phenomenon referred to as conditioned pain modulation (CPM). The efficiency of CPM is predictive of a variety of health outcomes, while impaired CPM has been associated with various chronic pain conditions. Current methods used to assess CPM vary widely, and interest in CPM method development remains strong. Here, we evaluated a novel method for assessing CPM in healthy controls and fibromyalgia (FM) patients using thumb pressure as both a test and conditioning stimulus. Methods Sixteen female FM patients and 14 matched healthy controls underwent CPM testing with thumbnail pressure as the test stimulus, and either cold water or noxious pressure as the conditioning stimulus. CPM magnitude was evaluated as the difference in pain rating of the test stimulus applied before and during the conditioning stimulus. Results In healthy controls, application of either pressure or cold water conditioning stimulation induced CPM as evidenced by a significant reduction in test stimulus pain rating during conditioning (P=0.007 and P=0.021, respectively). In contrast, in FM patients, neither conditioning stimulus induced a significant CPM effect (P>0.274). There was a significant difference in CPM magnitude for FM patients compared to healthy controls with noxious pressure conditioning stimulation (P=0.023); however, no significant difference in CPM was found between groups using cold water as a conditioning stimulus (P=0.269). Conclusion The current study demonstrates that thumbnail pressure can be used as both a test and conditioning stimulus in the assessment of CPM. This study further confirms previous findings of attenuated CPM in FM patients compared with healthy controls. PMID:27713648
Physiological effects of positive pressure breathing with pure oxygen and a low oxygen gas mixture.
Liu, Xiaopeng; Xiao, Huajun; Shi, Weiru; Wen, Dongqing; Yu, Lihua; Chen, Jianzhang
2015-01-01
Positive pressure breathing (PPB) can cause circulatory dysfunction due to peripheral pooling of blood. This study explored a better way at ground level to simulate pure oxygen PPB at 59,055 ft (18,000 m) by comparing the physiological changes during PPB with pure oxygen and low oxygen at ground level. Six subjects were exposed to 3 min of 69-mmHg PPB and 3 min of 59-mmHg PPB with pure oxygen and low oxygen while wearing the thoracic counterpressure jerkin inflated to 1× breathing pressure and G-suit inflated to 3 and 4× breathing pressure. Stroke volume (SV), cardiac output (CO), heart rate (HR), and peripheral oxygen saturation (Spo2) were measured. Subjects completed a simulating flying task (SFT) during 3-min PPB and scores were recorded. HR and SV responses differed significantly between breathing pure oxygen and low oxygen. CO response was not significantly different for pure oxygen and low oxygen, the two levels of PPB, and the two levels of G-suit pressure. Spo2 declined as a linear function of time during low-oxygen PPB and there was a significant difference in Spo2 response for the two levels of PPB. The average score of SFT during pure oxygen PPB was 3970.5 ± 1050.4, which was significantly higher than 2708.0 ± 702.7 with low oxygen PPB. Hypoxia and PPB have a synergistic negative effect on both the cardiovascular system and SFT performance. PPB with low oxygen was more appropriate at ground level to investigate physiological responses during PPB and evaluate the protective performance of garments. Liu X, Xiao H, Shi W, Wen D, Yu L, Chen J. Physiological effects of positive pressure breathing with pure oxygen and a low oxygen gas mixture.
Wiegerinck, Johannes I; Boyd, Jennifer; Yoder, Jordan C; Abbey, Alicia N; Nunley, James A; Queen, Robin M
2009-04-01
The purpose of this study was to examine the difference in plantar loading between two different running shoe types. We hypothesized that a higher maximum force, peak pressure, and contact area would exist beneath the entire foot while running in a racing flat when compared to a training shoe. 37 athletes (17 male and 20 female) were recruited for this study. Subjects had no history of lower extremity injuries in the past six months, no history of foot or ankle surgery within the past 3 years, and no history of metatarsal stress fractures. Subjects had to be physically active and run at least 10 miles per week. Each subject ran on a 10m runway 7 times wearing two different running shoe types, the Nike Air Pegasus (training shoe) and the Nike Air Zoom Katana IV (racing flat). A Pedar-X in-shoe pressure measurement system sampling at 50Hz was used to collect plantar pressure data. Peak pressure, maximum force, and contact area beneath eight different anatomical regions of the foot as well as beneath the total foot were obtained. The results of this study demonstrated a significant difference between training shoes and racing flats in terms of peak pressure, maximum force, and contact area. The significant differences measured between the two shoes can be of importance when examining the influence of shoe type on the occurrence of stress fractures in runners.
Cox, Jill; Roche, Sharon; Van Wynen, Elizabeth
2011-02-01
To determine whether there was a difference in retention of knowledge about pressure ulcers with a traditional lecture versus computer-based instruction. A quasi-experimental, pretest/posttest design was used. Medical-surgical and critical care nurses (N = 60) were randomly assigned to a lecture, to computer-based instruction, or to a control group. Study participants were given the pressure ulcer knowledge test before and immediately after the program and at 3-month and 6-month intervals. Analysis of variance showed statistically significant differences in pretest and posttest scores [F(2, 57) = 35.784, p = .000] and in posttest to 3-month scores [F(2, 57) = 18.427, p = .000] among the three groups. The most significant loss of pressure ulcer knowledge, regardless of educational method, occurred within the first 3 months. Based on these findings, quarterly education in pressure ulcer prevention is recommended to maintain knowledge. Computer-based instruction is a viable option for acquisition and retention of knowledge about pressure ulcer prevention. Copyright 2011, SLACK Incorporated.
Tortolani, P Justin; Cunningham, Bryan W; Vigna, Franco; Hu, Nianbin; Zorn, Candace M; McAfee, Paul C
2006-07-01
Dysphagia is a well-recognized complication after anterior cervical discectomy and fusion, observed in as high as 50% of cases by videofluoroscopic evaluation postoperatively. Esophageal injury due to surgical retraction is a complication due to which swallowing difficulties may ensue. There are limited published data evaluating the effect of soft tissue retraction on intraesophageal pressures during anterior cervical instrumentation procedures. The purpose of this study was to (a) measure the intraesophageal pressure secondary to retraction during anterior instrumentation, (b) determine whether any pressure differences exist between plating and cervical disc replacement, and (c) determine whether the surgical level or length of the plate influences the magnitude of intraesophageal pressure during retraction. An analysis of soft tissue retraction pressure was performed for anterior single-level and 3-level cervical plating and cervical disc replacement procedures. Using a 4-cm transverse incision, a Smith-Robinson anterior approach to the cervical spine was performed on 7 fresh, frozen cadavers. The correct placement of an esophageal pressure-transducing catheter was confirmed by laryngoscopy, manual palpation of the esophagus, and fluoroscopic imaging. Three surgical instrumentation groups were used for comparisons: (a) single-level plate (b) single-level Porous Coated Motion cervical disc replacement, and (c) 3-level plate. Hand-held appendiceal retractors were used to retract the soft tissues during screw insertion into the plate and during application of the disc prosthesis into the interspace. Care was taken to exert just enough force on the retractors to allow the surgeon to move the desired implant into the correct position. In addition the individual performing the retraction was blinded to the procedure being performed-1-level plating, 3-level plating, or disk replacement. Fluoroscopy confirmed that the pressure sensors were directly behind the retractors during data acquisition. Significantly greater intraesophageal pressures were demonstrated for single-level cervical plating at C5-6 compared to that at C3-4 (P=0.036). Similarly, significantly greater pressures were recorded at C5-6 versus C3-4 for the 3-level plating group (P<0.001). In contrast, there was no statistically significant difference in pressures observed during disk replacement at C5-6 compared to that at C3-4 (P=0.084). Significantly greater pressures were recorded during single-level plating compared to disc replacement at both C3-4 (P=0.016) and C5-6 (P=0.016). Three-level plating demonstrated significantly greater pressures at C5-6 compared to disk replacement (P<0.001) but no statistically significant difference compared to disk replacement at C3-4 (P=0.333). The highest mean pressure, 154.5+/-49.5 mm Hg, was recorded at C5-6 level during insertion of the 3-level plates. On the basis of the data presented here, anterior cervical plating results in significantly greater intraesophageal pressures when performed at C5-6 compared to C3-4. This holds regardless of whether the plate spans the distance from C3 to C6 (3-level plate) or the single C5-6 level. In addition, the insertion of the cervical disc replacement seems to require less esophageal retraction and hence reduced intraesophageal pressures when compared to anterior cervical plating.
Ovo-vegetarian diet is associated with lower systemic blood pressure in Taiwanese women.
Ho, C P; Yu, J H; Lee, T J F
2017-12-01
This study was designed to investigate blood pressure (BP) profiles among Taiwanese women with different dietary patterns. Cross-sectional study. A total of 269 non-hypertensive Taiwanese women, 40 years of age or older, were surveyed using structured questionnaires, and measurements of BP and physiological parameters were made. To assess differences among vegans, ovo-vegetarians, and meat eaters in terms of BP, demographic, and health behavior data, the chi-squared and Fisher's exact tests were employed for categorical variables, and analysis of variance and independent t-tests were performed for continuous variables. Multiple regression analysis was used to examine the relationship between BP and dietary patterns while controlling for potential confounding factors. A significant difference was found among the three test groups in terms of age, education, employment, stress, and waist-hip ratio. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) significantly differed among the three groups. After controlling for age, body weight, waist circumference, and hip circumference, the three groups were observed to be a significant risk factor of the SBP and DBP. The SBP and DBP of the ovo-vegetarian group were significantly lower than those of the meat-eater group. No significant differences were found between the vegan and meat-eater groups in terms of SBP and DBP. Dietary pattern is a likely risk factor for SBP and DBP outcomes in Taiwanese women. In particular, the SBP and DBP of ovo-vegetarians are the lowest among the values observed for all dietary patterns. This finding suggests that an ovo-vegetarian diet is beneficial for long-term BP control and prevention of hypertension in females. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Yanagisawa, Yukio; Matsuo, Yoshimi; Shuntoh, Hisato; Mitamura, Masaaki; Horiuchi, Noriaki
2013-01-01
[Purpose] The purpose of this study was to investigate the effect of expiratory resistance load on the tongue area encompassing the suprahyoid and genioglossus muscles. [Subjects] The subjects were 30 healthy individuals (15 males, 15 females, mean age: 28.9 years). [Methods] Magnetic resonance imaging was used to investigate morphological changes in response to resistive expiratory pressure loading in the area encompassing the suprahyoid and genioglossus muscles. Images were taken when water pressure was sustained at 0%, 10%, 30%, and 50% of maximum resistive expiratory pressure. We then measured tongue area using image analysis software, and the morphological changes were analyzed using repeated measures analysis of variance followed by post hoc comparisons. [Results] A significant change in the tongue area was detected in both sexes upon loading. Multiple comparison analysis revealed further significant differences in tongue area as well as changes in tongue area in response to the different expiratory pressures. [Conclusion] The findings demonstrate that higher expiratory pressure facilitates greater reduction in tongue area. PMID:24259824
Hillebrand, Matthias; Nouri, Ghazaleh; Hametner, Bernhard; Parragh, Stephanie; Köster, Jelena; Mortensen, Kai; Schwarz, Achim; von Kodolitsch, Yskert; Wassertheurer, Siegfried
2016-05-06
The aim of this work is the investigation of measures of ambulatory brachial and aortic blood pressure and indices of arterial stiffness and aortic wave reflection in Marfan patients. A case-control study was conducted including patients with diagnosed Marfan syndrome following Ghent2 nosology and healthy controls matched for sex, age and daytime brachial systolic blood pressure. For each subject a 24 h ambulatory blood pressure and 24 h pulse wave analysis measurement was performed. All parameters showed a circadian pattern whereby pressure dipping was more pronounced in Marfan patients. During daytime only Marfan patients with aortic root surgery showed increased pulse wave velocity. In contrast, various nighttime measurements, wave reflection determinants and circadian patterns showed a significant difference. The findings of our study provide evidence that ambulatory measurement of arterial stiffness parameters is feasible and that these determinants are significantly different in Marfan syndrome patients compared to controls in particular at nighttime. Further investigation is therefore indicated.
Shu, Liqin; Huang, Kun
2018-07-01
Evidence suggests that supplementation of vitamin D cannot decrease blood pressure in normal populations. However, in randomized controlled trials (RCTs) with vitamin D deficient participants (defined as baseline serum 25[OH]D levels <30 ng/mL or 50 nmol/L), this effect is inconsistent and under debate. Thus, we performed this systematic review and meta-analysis to evaluate whether vitamin D supplementation could affect blood pressure parameters in vitamin D-deficient subjects. The PubMed, Web of Science, ScienceDirect, and Cochrane library databases were searched. Extracted data were pooled as weighted mean differences with 95% confidence intervals to evaluate the effects. Subgroup analysis was further conducted according to the characteristics of included studies. Seven RCTs that contained 560 participants were included in our meta-analysis. The pooled weighted mean difference of peripheral diastolic blood pressure was -1.65 mm Hg (95% confidence interval: -3.05 to -0.25, I 2 = 30.3%). No significant effect of vitamin D supplementation was found on other parameters. Subgroup analysis showed a significant decrease in peripheral systolic blood pressure and diastolic blood pressure in Asia, 8 weeks of intervention, and more than 5000 IU of daily vitamin D supplementation subgroups. For vitamin D-deficient patients, there is a small but significant fall in peripheral blood pressure but no significant fall in other blood pressure parameters with vitamin D supplementation. Further RCTs with large numbers of participants is still warranted to confirm these effects. Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.
Sudarma, Verawati; Sukmaniah, Sri; Siregar, Parlindungan
2011-10-01
to investigate the effect of consumption of dark chocolate 30 g/day for fifteen days on Nitric oxide (NO) serum levels and blood pressure in male and female employees with prehypertension. the study was a parallel randomized clinical trial. A total of thirty-two subjects was divided into two groups using block randomization. Sixteen subjects received 30 g/day dark chocolate and dietary counseling (treatment group) and the other 16 subjects received white chocolate 25 g/day and dietary counseling (control group) for fifteen days. Data collected in this study consisted of age, physical activity, body massa index, intake of energy, intake of sodium, and intake of polyphenol, NO serum levels and blood pressure. The measurement of NO serum levels was done in pre- and after- treatment, while blood pressure was assessed in pre- , during- and after- treatment. Statistical analysis was performed using independent t-test for normal distribution data and Mann-Whitney test for not normal distribution data, with the level of significancy of 5%. after 15 days treatment, NO serum level between treatment and control groups were significantly different 7.70 ± 3.84 vs 1.92(-0.79 ± 17.78) (p=0.001). Both groups had decreased systolic and diastolic blood pressure. Systolic blood pressure was different significantly between groups after treatment 120.64 ± 8.47 vs 131.19 ± 7.45 (p=0.001), while diastolic blood pressure was not significant 74.14 ± 6.30 vs 77.44 ± 10.29 (p=0.308). in prehypertension subjects, dark chocolate 30 g/day increased NOx serum levels and decreased systolic blood pressure after 15 days of treatment.
Modeling the pyrolysis study of non-charring polymers under reduced pressure environments
NASA Astrophysics Data System (ADS)
Zong, Ruowen; Kang, Ruxue; Hu, Yanghui; Zhi, Youran
2018-04-01
In order to study the pyrolysis of non-charring polymers under reduced pressure environments, a series of experiments based on black acrylonitrile butadiene styrene (ABS) was conducted in a reduced pressure chamber under different external heat fluxes. The temperatures of the top surface and the bottom of the sample and the mass loss during the whole process were measured in real time. A one-dimensional numerical model was developed to predict the top surface and the bottom surface temperatures of ABS during the pyrolysis at different reduced pressures and external heat fluxes, and the model was validated by the experimental data. The results of the study indicate that the profiles of the top surface and the bottom surface temperatures are different at different pressures and heat fluxes. The temperature and the mass loss rate of the sample under a lower heat flux decreased significantly as the pressure was increased. However, under a higher heat flux, the temperature and the mass loss rate showed little sensitivity to the pressure. The simulated results fitted the experimental results better at the higher heat flux than at the lower heat flux.
Darrah, Shaun D; Dicianno, Brad E; Berthold, Justin; McCoy, Andrew; Haas, Matthew; Cooper, Rory A
2016-01-01
To determine whether sledge hockey players with physical disability have higher average seated pressures compared to non-disabled controls. Fifteen age-matched controls without physical disability and 15 experimental participants with physical disability were studied using a pressure mapping device to determine risk for skin pressure ulceration and the impact of cushioning and knee angle positioning on seated pressure distributions. Regardless of participant group, cushioning, or knee angle, average seated pressures exceeded clinically acceptable seated pressures. Controls had significantly higher average seated pressures than the disability group when knees were flexed, both with the cushion (p = 0.013) and without (p = 0.015). Knee extension showed significantly lower average pressures in controls, both with the cushion (p < 0.001) and without (p < 0.001). Placement of the cushion resulted in significantly lower average pressure in controls when knees were extended (p = 0.024) but not when flexed (p = 0.248). Placement of the cushion resulted in no difference in pressure (p = 0.443) in the disability group. Pressures recorded indicate high risk for skin ulceration. Cushioning was effective only in the control group with knees extended. That knee extension significantly lowered average seated pressures is important, as many sledge hockey players utilize positioning with larger knee flexion angles. Implications for Rehabilitation Ice sledge hockey is a fast growing adaptive sport. Adaptive sports have been associated with several positive improvements in overall health and quality of life, though may be putting players at risk for skin ulceration. Measured static seated pressure in sledges greatly exceeds current clinically accepted clinical guidelines. With modern improvements in wheelchair pressure relief/cushioning there are potential methods for improvement of elevated seated pressure in ice hockey sledges.
Pore-scale modeling of wettability effects on CO2-brine displacement during geological storage
NASA Astrophysics Data System (ADS)
Basirat, Farzad; Yang, Zhibing; Niemi, Auli
2017-11-01
Wetting properties of reservoir rocks and caprocks can vary significantly, and they strongly influence geological storage of carbon dioxide in deep saline aquifers, during which CO2 is supposed to displace the resident brine and to become permanently trapped. Fundamental understanding of the effect of wettability on CO2-brine displacement is thus important for improving storage efficiency and security. In this study, we investigate the influence of wetting properties on two-phase flow of CO2 and brine at the pore scale. A numerical model based on the phase field method is implemented to simulate the two-phase flow of CO2-brine in a realistic pore geometry. Our focus is to study the pore-scale fluid-fluid displacement mechanisms under different wetting conditions and to quantify the effect of wettability on macroscopic parameters such as residual brine saturation, capillary pressure, relative permeability, and specific interfacial area. Our simulation results confirm that both the trapped wetting phase saturation and the normalized interfacial area increase with decreasing contact angle. However, the wetting condition does not appear to influence the CO2 breakthrough time and saturation. We also show that the macroscopic capillary pressures based on the pressure difference between inlet and outlet can differ significantly from the phase averaging capillary pressures for all contact angles when the capillary number is high (log Ca > -5). This indicates that the inlet-outlet pressure difference may not be a good measure of the continuum-scale capillary pressure. In addition, the results show that the relative permeability of CO2 can be significantly lower in strongly water-wet conditions than in the intermediate-wet conditions.
Hydrostatic paradox: experimental verification of pressure equilibrium
NASA Astrophysics Data System (ADS)
Kodejška, Č.; Ganci, S.; Říha, J.; Sedláčková, H.
2017-11-01
This work is focused on the experimental verification of the balance between the atmospheric pressure acting on the sheet of paper, which encloses the cylinder completely or partially filled with water from below, where the hydrostatic pressure of the water column acts against the atmospheric pressure. First of all this paper solves a theoretical analysis of the problem, which is based, firstly, on the equation for isothermal process and, secondly, on the equality of pressures inside and outside the cylinder. From the measured values the confirmation of the theoretical quadratic dependence of the air pressure inside the cylinder on the level of the liquid in the cylinder is obtained, the maximum change in the volume of air within the cylinder occurs for the height of the water column L of one half of the total height of the vessel H. The measurements were made for different diameters of the cylinder and with plates made of different materials located at the bottom of the cylinder to prevent liquid from flowing out of the cylinder. The measured values were subjected to statistical analysis, which demonstrated the validity of the zero hypothesis, i.e. that the measured values are not statistically significantly different from the theoretically calculated ones at the statistical significance level α = 0.05.
Effects of shoe sole hardness on plantar pressure and comfort in older people with forefoot pain.
Lane, Tamara J; Landorf, Karl B; Bonanno, Daniel R; Raspovic, Anita; Menz, Hylton B
2014-01-01
Plantar forefoot pain is common in older people and is related to increased peak pressures under the foot during gait. Variations in the hardness of the shoe sole may therefore influence both the magnitude of loading under the foot and the perceived comfort of the shoe in this population. The aim of this investigation was to determine the effect of varying shoe sole hardness on plantar pressures and comfort in older people with forefoot pain. In-shoe plantar pressures under the forefoot, midfoot and rearfoot were recorded from 35 older people (mean age 73.2, SD 4.5 years) with current or previous forefoot pain using the pedar-X(®) system. Participants walked at their normal comfortable speed along an 8m walkway in shoes with three different levels of sole hardness: soft (Shore A25), medium (Shore A40) and hard (Shore A58). Shoe comfort was measured on a 100mm visual analogue scale. There were statistically significant differences in peak pressure of between 5% and 23% across the forefoot, midfoot and rearfoot (p<0.01). The hard-soled shoe registered the highest peak pressures and the soft-soled shoe the lowest peak pressures. However, no differences in comfort scores across the three shoe conditions were observed. These findings demonstrate that as shoe sole hardness increases, plantar pressure increases, however this does not appear to have a significant effect on shoe comfort. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Shim, Je-Myung; Jung, Ju-Hyeon; Kim, Hwan-Hee
2015-07-01
[Purpose] The aim of this study was to examine whether plantar flexor static stretching and dynamic stretching using an Aero-Step results in changes in foot pressure during gait in healthy adults. [Subjects] Eighteen normal adults were randomly allocated to either a dynamic stretching using an Aero-Step group (DSUAS) group (n = 8) or a static stretching (SS) group (n = 10). [Methods] The DSUAS and SS participants took part in an exercise program for 15 minutes. Outcome measures were foot plantar pressure, which was measured during the subject's gait stance phase; the asymmetric ratio of foot pressure for both feet; and the visual analogue scale (VAS) measured during the interventions. [Results] There were significant differences in the asymmetric ratio of foot pressure for both feet and VAS between the two groups after intervention. However, there were no significant differences in foot plantar pressure during the gait stance phase within both groups. [Conclusion] DSUSAS is an effective stretching method, as pain during it is lower than that with SS, which can minimize the asymmetric ratio of foot pressure for both feet during gait due to asymmetric postural alignment.
Pulmonary function of children with acute leukemia in maintenance phase of chemotherapy☆
de Macêdo, Thalita Medeiros Fernandes; Campos, Tania Fernandes; Mendes, Raquel Emanuele de França; França, Danielle Corrêa; Chaves, Gabriela Suéllen da Silva; de Mendonça, Karla Morganna Pereira Pinto
2014-01-01
OBJECTIVE: The aim of this study was to assess the pulmonary function of children with acute leukemia. METHODS: Cross-sectional observational analytical study that enrolled 34 children divided into groups A (17 with acute leukemia in the maintenance phase of chemotherapy) and B (17 healthy children). The groups were matched for sex, age and height. Spirometry was measured using a spirometer Microloop Viasys(r) in accordance with American Thoracic Society and European Respiratory Society guidelines. Maximal respiratory pressures were measured with an MVD300 digital manometer (Globalmed(r)). Maximal inspiratory pressures and maximal expiratory pressures were measured from residual volume and total lung capacity, respectively. RESULTS: Group A showed a significant decrease in maximal inspiratory pressures when compared to group B. No significant difference was found between the spirometric values of the two groups, nor was there any difference between maximal inspiratory pressure and maximal expiratory pressure values in group A compared to the lower limit values proposed as reference. CONCLUSION: Children with acute leukemia, myeloid or lymphoid, during the maintenance phase of chemotherapy exhibited unchanged spirometric variables and maximal expiratory pressure; However, there was a decrease in inspiratory muscle strength. PMID:25510995
Qiu, Wusi; Jiang, Qizhou; Xiao, Guoming; Wang, Weiming; Shen, Hong
2014-01-01
Intracranial-pressure (ICP) monitoring is useful for patients with increased ICP following hemorrhagic stroke. In this study, the changes in pressure gradients between the two cerebral hemispheres were investigated after hemorrhagic stroke of one side, and after a craniotomy. Twenty-four patients with acute cerebral hemorrhages and intracerebral hematomas who exhibited mass effect and midline shift to the contralateral side on computed tomography were selected for this study. After admission, both sides of the cranium were drilled, and optical fiber sensors were implanted to monitor the brain parenchyma pressure (BPP) in both cerebral hemispheres. All patients underwent surgical hematoma evacuations. The preoperative and postoperative BPP data from both cerebral hemispheres were collected at various time points and compared pairwise. There were statistically significant differences (P < 0.01) in the preoperative BPP values between the two hemispheres at three different time points. Differences in the BPP values between the two hemispheres at the time of surgery, and 24 and 48 h after surgery, were not statistically significant (P > 0.05). The posteroperative BPPs of both hemispheres were statistically significantly lower than preoperative recordings. BPP sensors should be applied to the injured cerebral hemisphere, because this becomes the source of increased ICP. Hematoma evacuation surgery effectively decreases ICP and eliminates pressure gradients between the two cerebral hemispheres, consequently enabling brain shift correction.
The Comparison of Dietary Behaviors among Rural Controlled and Uncontrolled Hypertensive Patients.
Kamran, Aziz; Shekarchi, Ali Akbar; Sharifian, Elham; Heydari, Heshmatolah
2016-01-01
Nutrition is a dominant peripheral factor in increasing blood pressure; however, little information is available about the nutritional status of hypertensive patients in Iran. This study aimed to compare nutritional behaviors of the rural controlled and uncontrolled hypertensive patients and to determine the predictive power of nutritional behaviors from blood pressure. This cross-sectional study was conducted on 671 rural hypertensive patients, using multistage random sampling method in Ardabil city in 2013. Data were collected by a 3-day food record questionnaire. Nutritional data were extracted by Nutritionist 4 software and analyzed by the SPSS 18 software using Pearson correlation, multiple linear regression, ANOVA, and independent t-test. A significant difference was observed in the means of fat intake, cholesterol, saturated fat, sodium, energy, calcium, vitamin C, fiber, and nutritional knowledge between controlled and uncontrolled groups. In the controlled group, sodium, saturated fats, vitamin C, calcium, and energy intake explained 30.6% of the variations in blood pressure and, in the uncontrolled group, sodium, carbohydrate, fiber intake, and nutritional knowledge explained 83% of the variations in blood pressure. There was a significant difference in the nutritional behavior between the two groups and changes in blood pressure could be explained significantly by nutritional behaviors.
Sun, Yong-Wei; Chen, Wei; Luo, Meng; Hua, Rong; Liu, Wei; Huo, Yan-Miao; Wu, Zhi-Yong; Cao, Hui
2010-06-01
Various surgical procedures can be used to treat liver cirrhosis and portal hypertension. How to select the most appropriate procedure for patients with portal hypertension has become a difficult problem. This study aimed to analyze the relationship between the value of intraoperative free portal pressure (FPP) and postoperative complications, and to explore the significance of intraoperative FPP measurement with respect to surgical procedure selection. The clinical data of 187 patients with portal hypertension who received pericardial devascularization and proximal splenorenal shunt combined with devascularization (combined operation) at the Department of General Surgery in our hospital from January 2001 to September 2008 were retrospectively analyzed. Among the patients who received pericardial devascularization, those with a postoperative FPP >or=22 mmHg were included in a high-pressure group (n=68), and those with FPP <22 mmHg were in a low-pressure group (n=49). Seventy patients who received the combined operation comprised a combined group. The intraoperative FPP measurement changes at different times, and the incidence of postoperative complications in the three groups of patients were compared. The postoperative FPP value in the high-pressure group was 27.5+/-2.3 mmHg, which was significantly higher than that of the low-pressure (20.9+/-1.8 mmHg) or combined groups (21.7+/-2.5 mmHg). The rebleeding rate in the high-pressure group was significantly higher than that in the low-pressure and combined groups. The incidence rates of postoperative hepatic encephalopathy and liver failure were not statistically different among the three groups. The mortality due to rebleeding in the low-pressure and combined groups (0.84%) was significantly lower than that of the high-pressure group. The study demonstrates that FPP is a critical measurement for surgical procedure selection in patients with portal hypertension. A FPP value >or=22 mmHg after splenectomy and devascularization alone is an important indicator that an additional proximal splenorenal shunt needs to be performed.
Caruana, Emmanuel; Chevret, Sylvie; Pirracchio, Romain
2017-03-01
The benefit of cricoid pressure during tracheal intubation is still debated and, due to its potential negative impact on laryngeal views, its routine use is questioned. The goal of this study was to estimate its impact on laryngeal view. All patients intubated in the prehospital setting were included. Three different propensity score (PS) models were used and compared in terms of the balance achieved between those patients who received cricoid pressure and those who did not. The PS model that optimised the balance was retained in order to estimate the relationship between cricoid pressure and the following outcomes: difficult laryngoscopy, intubation-related complications and difficult intubation. Among the 1195 patients included, 499 (41.7%) received cricoid pressure. The optimal PS included seven variables (cardiac arrest, altered neurological status, shock, respiratory distress, gender, obesity, patient's position). After PS matching, no significant risk difference (RD) in the rate of difficult laryngoscopy was found between the patients who received cricoid pressure and those who did not (RD=0.001, 95% CI -0.07 to 0.08, p=0.50). No significant difference was found in terms of difficult intubation (RD=0.06, 95% CI -0.13 to 0.25, p=0.28) and in terms of prevalence of complications, except for airway trauma that were more frequent in cricoid pressure group (RD=0.03, 95% CI 0.002 to 0.05, p=0.01). No significant relationship was found between the use of cricoid pressure for prehospital intubation and difficult laryngoscopy. Cricoid pressure was found to be associated with more airway trauma. This finding could question its routine use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Does vaginal closure force differ in the supine and standing positions?
Morgan, Daniel M; Kaur, Gurpreet; Hsu, Yvonne; Fenner, Dee E; Guire, Kenneth; Miller, Janis; Ashton-Miller, James A; Delancey, John O L
2005-05-01
This study was undertaken to quantify resting vaginal closure force (VCF(REST)), maximum vaginal closure force (VCF(MAX)), and augmentation of vaginal closure force augmentation (VCF(AUG)) when supine and standing and to determine whether the change in intra-abdominal pressure associated with change in posture accounts for differences in VCF. Thirty-nine asymptomatic, continent women were recruited to determine, when supine and standing, the vaginal closure force (eg, the force closing the vagina in the mid-sagittal plane) and bladder pressures at rest and at maximal voluntary contraction. VCF was measured with an instrumented vaginal speculum and bladder pressure was determined with a microtip catheter. VCF(REST) was the resting pelvic floor tone, and VCF(MAX) was the peak pelvic floor force during a maximal voluntary contraction. VCF(AUG) was the difference between VCF(MAX) and VCF(REST). T tests and Pearson correlation coefficients were used for analysis. VCF(REST) when supine was 3.6 +/- 0.8 N and when standing was 6.9 +/- 1.5 N--a 92% difference (P < .001). The VCF(MAX) when supine was 7.5 +/- 2.9 N and when standing was 10.1 +/- 2.4 N--a 35% difference (P < .001). Bladder pressure when supine (10.5 +/- 4.7 cm H2O) was significantly less (P < .001) than when standing (31.0 +/- 6.4 cm H2O). The differences in bladder pressure when either supine or standing did not correlate with the corresponding differences in VCF at rest or at maximal voluntary contraction. The supine VCF(AUG) of 3.9 +/- 2.7 N, was significantly greater than the standing VCF(AUG) of 3.3+/-1.9 N. With change in posture, vaginal closure force increases because of higher intra-abdominal pressure and greater resistance in the pelvic floor muscles.
Cell Phone Information Seeking Explains Blood Pressure in African American Women.
Jones, Lenette M; Veinot, Tiffany C; Pressler, Susan J
2018-05-01
Although cell phone use and Internet access via cell phone is not marked by racial disparities, little is known about how cell phone use relates to blood pressure and health information seeking behaviors. The purposes of this study were to (a) describe Internet activities, cell phone use, and information seeking; (b) determine differences in blood pressure and information seeking between cell phone information seekers and nonseekers; and (c) examine cell phone information seeking as a predictor of blood pressure in African American women. Participants ( N = 147) completed a survey and had their blood pressure measured. Independent-sample t tests showed a significant difference in systolic blood pressure in cell phone information seekers and nonseekers. Linear regression revealed cell phone information seeking as an independent predictor of systolic blood pressure, despite confounders. It is possible that cell phone information seekers were using health information to make decisions about self-management of blood pressure.
Nishioka, Terumi; Takai, Yuichiro; Kawaradani, Mitsuo; Okada, Kiyotsugu; Tanimoto, Hideo; Misawa, Tatsuya; Kusakari, Shinichi
2014-01-01
Gas plasma generated and applied under two different systems, atmospheric pressure plasma and low pressure plasma, was used to investigate the inactivation efficacy on the seedborne pathogenic fungus, Rhizoctonia solani, which had been artificially introduced to brassicaceous seeds. Treatment with atmospheric plasma for 10 min markedly reduced the R. solani survival rate from 100% to 3% but delayed seed germination. The low pressure plasma treatment reduced the fungal survival rate from 83% to 1.7% after 10 min and the inactivation effect was dependent on the treatment time. The seed germination rate after treatment with the low pressure plasma was not significantly different from that of untreated seeds. The air temperature around the seeds in the low pressure system was lower than that of the atmospheric system. These results suggested that gas plasma treatment under low pressure could be effective in disinfecting the seeds without damaging them.
Thomson, Merran A; Yoder, Bradley A; Winter, Vicki T; Giavedoni, Luis; Chang, Ling Yi; Coalson, Jacqueline J
2006-11-01
Using the 125-day baboon model of bronchopulmonary dysplasia treated with prenatal steroid and exogenous surfactant, we hypothesized that a delay of extubation from low tidal volume positive pressure ventilation to nasal continuous positive airway pressure at 5 days (delayed nasal continuous positive airway pressure group) would not induce more lung injury when compared with baboons aggressively weaned to nasal continuous positive airway pressure at 24 hours (early nasal continuous positive airway pressure group), because both received positive pressure ventilation. After delivery by cesarean section at 125 days (term: 185 days), infants received 2 doses of Curosurf (Chiesi Farmaceutica S.p.A., Parma, Italy) and daily caffeine citrate. The delay in extubation to 5 days resulted in baboons in the delayed nasal continuous positive airway pressure group having a lower arterial to alveolar oxygen ratio, high PaCO2, and worse respiratory function. The animals in the delayed nasal continuous positive airway pressure group exhibited a poor respiratory drive that contributed to more reintubations and time on mechanical ventilation. A few animals in both groups developed necrotizing enterocolitis and/or sepsis, but infectious pneumonias were not documented. Cellular bronchiolitis and peribronchiolar alveolar wall thickening were more frequently seen in the delayed nasal continuous positive airway pressure group. Bronchoalveolar lavage levels of interleukin-6, interleukin-8, monocyte chemotactic protein-1, macrophage inflammatory protein-1 alpha, and growth-regulated oncogene-alpha were significantly increased in the delayed nasal continuous positive airway pressure group. Standard and digital morphometric analyses showed no significant differences in internal surface area and nodal measurements between the groups. Platelet endothelial cell adhesion molecule vascular staining was not significantly different between the 2 nasal continuous positive airway pressure groups. Volutrauma and/or low-grade colonization of airways secondary to increased reintubations and ventilation times are speculated to play causative roles in the delayed nasal continuous positive airway pressure group findings.
Practice versus knowledge when it comes to pressure ulcer prevention.
Provo, B; Piacentine, L; Dean-Baar, S
1997-09-01
This study was completed to determine the current knowledge and documentation patterns of nursing staff in the prevention of pressure ulcers and to identify the prevalence of pressure ulcers. This pre-post intervention study was carried out in three phases. In phase 1, 67 nursing staff members completed a modified version of Bostrom's Patient Skin Integrity Survey. A Braden Scale score, the presence of actual skin breakdown, and the presence of nursing documentation were collected for each patient (n = 43). Phase II consisted of a 20-minute educational session to all staff. In phase III, 51 nursing staff completed a second questionnaire similar to that completed in phase I. Patient data (n = 49) were again collected using the same procedure as phase I. Twenty-seven staff members completed questionnaires in both phase I and phase III of the study. No statistically significant differences were found in the knowledge of the staff before or after the educational session. The number of patients with a documented plan of care showed a statistically significant difference from phase I to phase III. The number of patients with pressure ulcers or at risk for pressure ulcer development (determined by a Braden Scale score of 16 or less) did not differ statistically from phase I to phase III. Knowledge about pressure ulcers in this sample of staff nurses was for the most part current and consistent with the recommendations in the Agency for Health Care Policy and Research guideline. Documentation of pressure ulcer prevention and treatment improved after the educational session. Although a significant change was noted in documentation, it is unclear whether it reflected an actual change in practice.
Alviar, Carlos L; Gutierrez, Alejandra; Cho, Leslie; Krishnaswamy, Amar; Saleh, Amr; Lincoff, Michael A; Roselli, Eric; Militello, Michael; Menon, Venu
2018-06-01
Sodium nitroprusside is the preferred agent for the treatment of high blood pressure during acute aortic syndrome if blood pressure remains elevated after heart rate control with beta-blockers. The increasing cost of sodium nitroprusside in the USA led us to assess the efficacy and safety of intravenous clevidipine, a calcium channel blocker with quick onset of action, short half-life and significantly lower costs than sodium nitroprusside, in patients presenting with acute aortic syndrome. We performed a retrospective chart review of consecutive patients admitted to the Cleveland Clinic Cardiac Intensive Care Unit from 2013-2016 with a diagnosis of acute aortic syndrome. Patients who received intravenous sodium nitroprusside were compared with those receiving intravenous clevidipine. The primary outcome was a significant difference in blood pressure at one, three and six hours. Secondary outcomes included time to achieving blood pressure target and in hospital mortality with rates of hypotension and bradycardia as safety endpoints. A total of 85 patients with suspected acute aortic pathology received clevidipine and 50 received sodium nitroprusside. Clinical and demographic characteristics were similar in both groups, except for a higher incidence of abdominal aortic aneurysm in the clevidipine group and for a trend towards higher use of labetalol in the clevidipine group. There were no significant differences in blood pressure or heart rate at one, three and six hours after starting either infusion. The rates of hypotension, bradycardia and in-hospital mortality did not differ. Time to achieve blood pressure control were also similar between groups. Intravenous clevidipine appears to be a safe and effective alternative to sodium nitroprusside for the management of high blood pressure during acute aortic dissection. In the USA, clevidipine could represent a cost effective therapy providing similar outcomes than sodium nitroprusside.
Pellegrino, Ana Cristina; Peñaflor, Maria Fernanda Gomes Villalba; Nardi, Cristiane; Bezner-Kerr, Wayne; Guglielmo, Christopher G; Bento, José Maurício Simões; McNeil, Jeremy N
2013-01-01
Prevailing abiotic conditions may positively or negatively impact insects at both the individual and population levels. For example while moderate rainfall and wind velocity may provide conditions that favour development, as well as movement within and between habitats, high winds and heavy rains can significantly decrease life expectancy. There is some evidence that insects adjust their behaviours associated with flight, mating and foraging in response to changes in barometric pressure. We studied changes in different mating behaviours of three taxonomically unrelated insects, the curcurbit beetle, Diabrotica speciosa (Coleoptera), the true armyworm moth, Pseudaletia unipuncta (Lepidoptera) and the potato aphid, Macrosiphum euphorbiae (Hemiptera), when subjected to natural or experimentally manipulated changes in atmospheric pressure. In response to decreasing barometric pressure, male beetles exhibited decreased locomotory activity in a Y-tube olfactometer with female pheromone extracts. However, when placed in close proximity to females, they exhibited reduced courtship sequences and the precopulatory period. Under the same situations, females of the true armyworm and the potato aphid exhibited significantly reduced calling behaviour. Neither the movement of male beetles nor the calling of armyworm females differed between stable and increasing atmospheric pressure conditions. However, in the case of the armyworm there was a significant decrease in the incidence of mating under rising atmospheric conditions, suggesting an effect on male behaviour. When atmospheric pressure rose, very few M. euphorbiae oviparae called. This was similar to the situation observed under decreasing conditions, and consequently very little mating was observed in this species except under stable conditions. All species exhibited behavioural modifications, but there were interspecific differences related to size-related flight ability and the diel periodicity of mating activity. We postulate that the observed behavioral modifications, especially under decreasing barometric pressure would reduce the probability of injury or death under adverse weather conditions.
Smooth muscle fatigue due to repeated urinary bladder neurostimulation: an in vivo study.
Bross, S; Schumacher, S; Scheepe, J R; Seif, C; Jünemann, K P; Alken, P
1999-01-01
The presented study investigates the influence of different pause lengths between two consecutive stimulations of the S3 roots on intravesical pressure during bladder neurostimulation. In eight male foxhounds (aged 7-18 months), laminectomy and placement of a modified Brindley electrode were performed. In four series with different pause lengths between two consecutive stimulations (1, 3, 5, and 15 min), the maximum intravesical pressure was measured during stimulation. The changes in intravesical pressure were registered in these four series, each series with six stimulations. A 15-min interval elapsed before the commencement of each series. In the series with a pause length of 15 min, the consecutive stimulations did not result in significant changes in maximum intravesical pressure. In the 5-min series, a significant decrease in intravesical pressure was not observed after the third stimulation. In the 3-min series, a significant decrease was seen at almost every stimulation (average decrease of 3.8% per stimulation) and in the 1-min series, a significant decrease was also observed at almost every stimulation (average decrease of 5.9% per stimulation). The results of repeated bladder neurostimulation demonstrate that the maximum intravesical pressure is dependent on the pause length between two consecutive stimulations. The detrusor muscle showed reversible and short-lived signs of fatigue. This implies the importance of a minimum 5-min interval between two subsequent stimulations. A pause length <5 min leads to a falsification of the results and thus to lower validity of the investigation.
Pressure distributions on a cambered wing body configuration at subsonic Mach numbers
NASA Technical Reports Server (NTRS)
Henderson, W. P.
1975-01-01
An investigation was conducted in the Langley high-speed 7- by 10-foot tunnel at Mach numbers of 0.20 and 0.40 and angles of attack up to about 22 deg to measure the pressure distributions on two cambered-wing configurations. The wings had the same planform (aspect ratio of 2.5 and a leading-edge-sweep angle of 44 deg) but differed in amounts of camber and twist (wing design lift coefficient of 0.35 and 0.70). The effects of wing strake on the wing pressure distributions were also studied. The results indicate that the experimental chordwise pressure distribution agrees reasonably well with the design distribution over the forward 60 percent of nearly all the airfoil sections for the lower cambered wing. The measured lifting pressures are slightly less than the design pressures over the aft part of the airfoil. For the highly cambered wing, there is a significant difference between the experimental and the design pressure level. The experimental distribution, however, is still very similar to the prescribed distribution. At angles of attack above 12 deg, the addition of a wing-fuselage strake results in a significant increase in lifting pressure coefficient at all wing stations outboard of the strake-wing intersection.
2016-01-01
Background. Changes in biomechanical structures of human foot are common in the older person, which may lead to alteration of foot type and plantar pressure distribution. We aimed to examine how foot type affects the plantar pressure distribution and to determine the relationship between plantar pressure distribution and functional reach distance in older persons. Methods. Fifty community-dwelling older persons (age: 69.98 ± 5.84) were categorized into three groups based on the Foot Posture Index. The plantar pressure (maxP) and contact area were analyzed using Footscan® RSScan platform. The Kruskal-Wallis test was used to compare the plantar pressure between foot types and Spearman's correlation coefficient was used to correlate plantar pressure with the functional reach distance. Results. There were significant differences of maxP in the forefoot area across all foot types. The post hoc analysis found significantly lower maxP in the pronated foot compared to the supinated foot. A high linear rank correlation was found between functional reach distance and maxP of the rearfoot region of the supinated foot. Conclusions. These findings suggested that types of the foot affect the plantar maximal pressure in older persons with functional reach distance showing some associations. PMID:27980874
Non-Gaussian PDF Modeling of Turbulent Boundary Layer Fluctuating Pressure Excitation
NASA Technical Reports Server (NTRS)
Steinwolf, Alexander; Rizzi, Stephen A.
2003-01-01
The purpose of the study is to investigate properties of the probability density function (PDF) of turbulent boundary layer fluctuating pressures measured on the exterior of a supersonic transport aircraft. It is shown that fluctuating pressure PDFs differ from the Gaussian distribution even for surface conditions having no significant discontinuities. The PDF tails are wider and longer than those of the Gaussian model. For pressure fluctuations upstream of forward-facing step discontinuities and downstream of aft-facing step discontinuities, deviations from the Gaussian model are more significant and the PDFs become asymmetrical. Various analytical PDF distributions are used and further developed to model this behavior.
The effect of fish oil supplements on blood pressure.
Lofgren, R P; Wilt, T J; Nichol, K L; Crespin, L; Pluhar, R; Eckfeldt, J
1993-01-01
We conducted a double-blind, placebo-controlled crossover study to determine the effects of fish oil supplementation on blood pressure in middle-aged men. Subjects were randomly assigned to consume either 20 g of fish oil or safflower oil for 12 weeks and then consume the other oil for an additional 12 weeks after a 4-week washout period. We found no significant changes from the pretreatment value in systolic or diastolic blood pressure with the use of fish oil supplements. In addition, there were no significant differences in the posttreatment blood pressures comparing the fish and safflower oil phases of the study. PMID:8427339
Hydraulic pressure inducing renal tubular epithelial-myofibroblast transdifferentiation in vitro.
Li, Fei-yan; Xie, Xi-sheng; Fan, Jun-ming; Li, Zi; Wu, Jiang; Zheng, Rong
2009-09-01
The effects of hydraulic pressure on renal tubular epithelial-myofibroblast transdifferentiation (TEMT) were investigated. We applied hydraulic pressure (50 cm H2O) to normal rat kidney tubular epithelial cells (NRK52E) for different durations. Furthermore, different pressure magnitudes were applied to cells. The morphology, cytoskeleton, and expression of myofibroblastic marker protein and transforming growth factor-beta1 (TGF-beta1) of NRK52E cells were examined. Disorganized actin filaments and formation of curling clusters in actin were seen in the cytoplasm of pressurized cells. We verified that de novo expression of alpha-smooth muscle actin induced by pressure, which indicated TEMT, was dependent on both the magnitude and duration of pressure. TGF-beta1 expression was significantly upregulated under certain conditions, which implies that the induction of TEMT by hydraulic pressure is related with TGF-beta1. We illustrate for the first time that hydraulic pressure can induce TEMT in a pressure magnitude- and duration-dependent manner, and that this TEMT is accompanied by TGF-beta1 secretion.
[Forefoot relief with shoe inserts : Effects of different construction strategies].
Baur, H; Merz, N; Muster, A; Flückiger, G; Hirschmüller, A
2018-04-01
Shoe inserts and shoe modifications are used to reduce plantar peak pressure. The effects of different shoe inserts and shoe construction strategies for relief of the forefoot have not yet been sufficiently evaluated. The aim of this study was to analyze the effects of shoe inserts and shoe construction strategies (e.g. metatarsal pad, forefoot cushioning and control) and shoe modifications (e.g. flexible or stiff) on the peak plantar pressure in the forefoot region. In this study 15 healthy subjects were recruited. Plantar pressure distribution was measured using an in-shoe system during walking (3.5km∙h -1 ) on a treadmill and the average plantar peak pressure (kPa) in the forefoot was calculated. The statistics for testing the hypothesis were carried out using 2‑factorial ANOVA with repeat measurements (factors: shoe, insert; α = 0.05). The metatarsal pad and forefoot cushioning led to a reduction of peak pressure, which was statistically significant compared to the control condition (p = 0.009). No differences were observed between both shoe inserts (p > 0.05). A comparison between stiff and flexible shoes revealed a statistically significant pressure reduction in favor of stiff shoes (p = 0.0001). The metatarsal pad led to a peak pressure increase in the midfoot of 12% and by 21% compared to control and forefoot cushioning, respectively. A peak pressure reduction in the forefoot can be achieved with a metatarsal pad or with cushioning; however, the metatarsal pad resulted in a subsequent increase in midfoot pressure. Moreover, shoe construction is crucial because a stiff shoe contributes to a better peak pressure reduction compared to a flexible shoe. Prospective clinical studies should be carried out to prove whether this results in beneficial effects for patients with metatarsalgia.
Amstrup Funder, Jonas; Christian Danielsen, Carl; Baandrup, Ulrik; Martin Bibby, Bo; Carl Andelius, Ted; Toft Brøndum, Emil; Wang, Tobias; Michael Hasenkam, J
2017-01-01
Heart valves which exist naturally in an extreme-pressure system must have evolved in a way to resist the stresses of high pressure. Giraffes are interesting as they naturally have a blood pressure twice that of humans. Thus, knowledge regarding giraffe heart valves may aid in developing techniques to design improved pressure-resistant biological heart valves. Heart valves from 12 giraffes and 10 calves were explanted and subjected to either biomechanical or morphological examinations. Strips from the heart valves were subjected to cyclic loading tests, followed by failure tests. Thickness measurements and analyses of elastin and collagen content were also made. Valve specimens were stained with hematoxylin and eosin, elastic van Gieson stain, Masson's trichrome and Fraser-Lendrum stain, as well as immunohistochemical reactions for morphological examinations. The aortic valve was shown to be 70% (95% CI 42-103%) stronger in the giraffe than in its bovine counterpart (p <0.001). No significant difference was found between mitral or pulmonary valves. After normalization for collagen, no significant differences were found in strength between species. The giraffe aortic valve was found to be significantly stiffer than the bovine aortic valve (p <0.001), with no significant difference between mitral and pulmonary valves. On a dry weight basis, the aortic (10.9%), pulmonary (4.3%), and mitral valves (9.6%) of giraffes contained significantly more collagen than those of calves. The elastin contents of the pulmonary valves (2.5%) and aortic valves (1.5%) were also higher in giraffes. The greater strength of the giraffe aortic valve is most likely due to a compact collagen construction. Both, collagen and elastin contents were higher in giraffes than in calves, which would make giraffe valves more resistant to the high-pressure forces. However, collagen also stiffens and thickens the valves. The mitral leaflets showed similar (but mostly insignificant) trends in strength, stiffness, and collagen content.
Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie
2010-03-01
We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Improvement of Diurnal Blood Pressure Variation by Azilsartan
Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori
2018-01-01
Background Azilsartan is an angiotensin II receptor blocker with a potent antihypertensive effect. Methods In a multicenter, prospective, open-label study, 265 patients with poor blood pressure control despite treatment with other angiotensin II receptor blockers were switched to 20 mg/day of azilsartan (patients on standard dosages) or 40 mg/day of azilsartan (patients on high dosages). Results Blood pressure was 149/83 mm Hg before switching and was significantly reduced from 1 month after switching until final assessment (132/76 mm Hg, P < 0.001). The pulse rate was 72/min before switching and increased significantly from 3 months after switching until final assessment (74/min, P < 0.005). A significant decrease of home morning systolic and diastolic pressure was observed from 1 and 3 months, respectively. Home morning blood pressure was 143/82 mm Hg before switching and 130/76 mm Hg at final assessment (P < 0.01). The morning-evening difference of systolic blood pressure decreased from 14.6 to 6.6 mm Hg after switching (P = 0.09). The estimated glomerular filtration rate was significantly decreased at 3, 6, and 12 months after switching, and serum uric acid was significantly increased at 12 months. No serious adverse events occurred. Conclusion Azilsartan significantly reduced the blood pressure and decreased diurnal variation in patients responding poorly to other angiotensin II receptor blockers. PMID:29238433
Schmid, Timo; Zurbriggen, Sebastian; Zderic, Ivan; Gueorguiev, Boyko; Weber, Martin; Krause, Fabian G
2013-09-01
A fixed cavovarus foot deformity can be associated with anteromedial ankle arthrosis due to elevated medial joint contact stresses. Supramalleolar valgus osteotomies (SMOT) and lateralizing calcaneal osteotomies (LCOT) are commonly used to treat symptoms by redistributing joint contact forces. In a cavovarus model, the effects of SMOT and LCOT on the lateralization of the center of force (COF) and reduction of the peak pressure in the ankle joint were compared. A previously published cavovarus model with fixed hindfoot varus was simulated in 10 cadaver specimens. Closing wedge supramalleolar valgus osteotomies 3 cm above the ankle joint level (6 and 11 degrees) and lateral sliding calcaneal osteotomies (5 and 10 mm displacement) were analyzed at 300 N axial static load (half body weight). The COF migration and peak pressure decrease in the ankle were recorded using high-resolution TekScan pressure sensors. A significant lateral COF shift was observed for each osteotomy: 2.1 mm for the 6 degrees (P = .014) and 2.3 mm for the 11 degrees SMOT (P = .010). The 5 mm LCOT led to a lateral shift of 2.0 mm (P = .042) and the 10 mm LCOT to a shift of 3.0 mm (P = .006). Comparing the different osteotomies among themselves no significant differences were recorded. No significant anteroposterior COF shift was seen. A significant peak pressure reduction was recorded for each osteotomy: The SMOT led to a reduction of 29% (P = .033) for the 6 degrees and 47% (P = .003) for the 11 degrees osteotomy, and the LCOT to a reduction of 41% (P = .003) for the 5 mm and 49% (P = .002) for the 10 mm osteotomy. Similar to the COF lateralization no significant differences between the osteotomies were seen. LCOT and SMOT significantly reduced anteromedial ankle joint contact stresses in this cavovarus model. The unloading effects of both osteotomies were equivalent. More correction did not lead to significantly more lateralization of the COF or more reduction of peak pressure but a trend was seen. In patients with fixed cavovarus feet, both SMOT and LCOT provided equally good redistribution of elevated ankle joint contact forces. Increasing the amount of displacement did not seem to equally improve the joint pressures. The site of osteotomy could therefore be chosen on the basis of surgeon's preference, simplicity, or local factors in case of more complex reconstructions.
Fritz, Caroline; Kimmoun, Antoine; Vanhuyse, Fabrice; Trifan, Bogdan Florin; Orlowski, Sophie; Falanga, Aude; Marie, Vanessa; Groubatch, Frederique; Albuisson, Eliane; Tran, N'Guyen; Levy, Bruno
2017-06-01
There is currently no recommendation for the mean arterial pressure target in the particular setting of Extracorporeal Cardiopulmonary Resuscitation (ECPR) in the first hours following cardiogenic shock complicated by cardiac arrest. This study aimed to assess the effects of two different levels of mean arterial pressure on macrocirculatory, microcirculatory, and metabolic functions. Randomized animal study. University research laboratory. Ventricular fibrillation was induced in 14 male pigs by surgical ligature of the interventricular coronary artery. After 20 min of cardiopulmonary resuscitation, Extracorporeal Life Support (ECLS) was initiated to restore circulatory flow. Thereafter, animals were randomly allocated to a high mean arterial pressure group (High-MAP, 80-85 mm Hg) or to a standard mean arterial pressure group (Standard-MAP, 65-70 mm Hg). Assessments conducted at baseline, immediately following and 6 h after ECLS initiation were focused on lactate evolution, amount of infused fluid, and microcirculatory parameters. There was no significant difference between the two groups at the time of ECLS initiation and at 6 h with regard to lactate levels (High-MAP vs. Standard-MAP: 8.8 [6.7-12.9] vs. 9.6 [9.1-9.8] mmol·l, P = 0.779 and 8.9 [4.3-11.1] vs. 3.3 [2.4-11] mmol·l, P = 0.603). Infused fluid volume did not significantly differ between the two groups (4,000 [3,500-12,000] vs. 5,000 [2,500-18,000] mL, P = 0.977). There was also no significant difference between the two groups regarding renal and liver functions, and sublingual capillary microvascular flow index assessed by Sidestream Dark Field imaging. Compared with a standard mean arterial pressure regimen, targeting a high mean arterial pressure in the first hours of an experimental ECPR model did not result in any hemodynamic improvement nor in a decrease in the amount of infused fluid.
Blood pressure, ethnic group, and salt intake in Belize.
Simmons, D
1983-03-01
A total of 1316 individuals were studied in seven villages in Belize, Central America. This represented 92% of the area population aged over 18. Generally, they were members of three ethnic groups--Maya, Spanish, and Creole. The systolic and diastolic IV and V blood pressures were recorded using standardised procedure. Significant differences in blood pressure, weight, and obesity were found between ethnic groups in both sexes, Creoles having higher means than the other groups. Significant relationships with blood pressure were found with obesity, age, and number of children. An early morning urine specimen was obtained from a random 50% of the men, and only in Creoles was there an association between raised blood pressure and sodium/potassium urinary excretion ratio.
Physical Activity, BMI, and Blood Pressure in US Youth: NHANES 2003-2006.
Betz, Heather Hayes; Eisenmann, Joey C; Laurson, Kelly R; DuBose, Katrina D; Reeves, Mathew J; Carlson, Joseph J; Pfeiffer, Karin A
2018-03-15
The objective of this study was to examine the independent and combined association of physical activity and body mass index (BMI) with blood pressure in youth. Youth aged 8-18 years from the 2003-2006 National Health and Nutrition Examination Survey (NHANES) with BMI, blood pressure, and physical activity (accelerometer) were included in the analyses. A total of 2585 subjects (1303 males; 47% of all 8- to 18-year-olds) met these criteria. Obese youth had a systolic blood pressure that was 8 mm Hg higher than normal weight youth. A significant interaction between BMI and physical activity on blood pressure was found (P < .001), and group differences among the BMI/activity groups showed that the 3 obese groups and the overweight/least active group had significantly higher systolic blood pressure than the normal weight/active group across all analyses. The overweight/least active and normal weight/least active groups had significantly higher diastolic blood pressure than the normal weight/active group as well. This study showed a significant independent and combined association of BMI and physical activity with blood pressure in youth. Interventions need to focus on the reduction of fatness/BMI as a way to reduce the cardiovascular risk in youth.
Evolution of ferromagnetism in charge ordered manganite: An effect of external pressure
NASA Astrophysics Data System (ADS)
Dash, S.; Pradhan, M. K.; Rao, T. Lakshmana
2018-05-01
Detailed magnetic measurements of the Pr0.75Na0.25MnO3 polycrystalline sample have been carried out under external hydrostatic pressure upto 10kbar. Pressure strongly suppresses the first order magnetic transition, while thermal hysteresis narrows down progressively and then disappears with increase in pressure. The significant enhancement of the field cooled magnetization value at different pressures is due to the antiferromagnetic to ferromagnetic transformation, while ruling out any contribution from the domain alignment within the ferromagnetic phase.
Get a Grip: Substrate Orientation and Digital Grasping Pressures in Strepsirrhines.
Congdon, Kimberly A; Ravosa, Matthew J
2016-01-01
Skeletal functional morphology in primates underlies many fossil interpretations. Understanding the functional correlates of arboreal grasping is central to identifying locomotor signatures in extinct primates. We tested 3 predictions linking substrate orientation and digital grasping pressures: (1) below-branch pressures are greater than above-branch and vertical-branch pressures; (2) there is no difference in pressure exerted across digits within autopods at any substrate orientation, and (3) there is no difference in pressure exerted between homologous digits across autopods at any substrate orientation. Adult males and females from 3 strepsirrhine species crossed an artificial arboreal substrate oriented for above-, below- and vertical-branch locomotion. We compared digital pressures within and across behaviors via ANOVA and Tukey's Honest Significant Difference test. Results show limited support for all predictions: below-branch pressures exceeded vertical-branch pressures and above-branch pressures for some digits and species (prediction 1), lateral digits often exerted greater pressures than medial digits (prediction 2), and pedal digits occasionally exerted greater pressures than manual digits during above-branch and vertical orientations but less often for below-branch locomotion (prediction 3). We observed functional variability across autopods, substrate and species that could underlie morphological variation within and across primates. Future work should consider the complexity of arboreality when inferring locomotor modes in fossils. © 2016 S. Karger AG, Basel.
Lindquist, Desirae E; Rowe, A Shaun; Heidel, Eric; Fleming, Travis; Yates, John R
2015-12-01
Two of the excipients in intravenous formulations of amiodarone, polysorbate 80 and benzyl alcohol, have been shown to cause hypotension. A newer formulation of amiodarone, which contains cyclodextrin, is devoid of these excipients. To evaluate the change in mean arterial pressure when utilizing 2 intravenous amiodarone formulations. This was a retrospective cohort analysis conducted at an academic medical center. Patients received intravenous amiodarone containing either polysorbate 80/benzyl alcohol (control) or cyclodextrin (cyclodextrin). Patients received these formulations based on a standard institutional protocol of 1 mg/min for 6 hours, followed by 0.5 mg/min for at least 18 hours or until discontinued by the provider. All data were collected from the medical record and included changes in blood pressures, time to lowest systolic blood pressure, concurrent antihypertensive use, and number of patients requiring treatment for hypotension. A total of 160 patients (120 control, 40 cyclodextrin) were included. There was a statistically significant difference in mean arterial pressure between the groups receiving the control formulation of amiodarone compared with the cyclodextrin formulation across the 24-hour maintenance phase infusion (P < 0.001). There was a significant difference between formulations with regard to the change in mean arterial pressure during the 0- to 6-hour and 12- to 18-hour time blocks. There was a statistically significant difference in the number of patients receiving fluid boluses for treatment of hypotension (P = 0.001). The excipients in the formulation of intravenous amiodarone may have a significant role in the hypotensive effects seen throughout the duration the maintenance phase infusion. © The Author(s) 2015.
Apan, A; Muluk, N Bayar; Güler, S; Budak, B
2013-01-01
The aim of this study was to investigate the effects of N2O-O2 mixture (Inspired O2 30%) on middle ear pressure (MEP) in children compared with the effects of an air-oxygen mixture (Inspired O2 50%). The study included thirty child patients who underwent general anaesthesia for different reasons, with the exception of ENT problems and ear interventions. They were randomly divided into two groups. Group 1 (15 children: 10 male and 5 female) received a N2O-O2 mixture (Inspired O2 30%); and group 2 (15 children: 10 male and 5 female) were given an air-oxygen mixture (Inspired O2 50%). MEP was measured using a portable impedance analyser before the operation (PreO),10 minutes after intubation (10AEn), 30 minutes after intubation (30AEn), 10 minutes before extubation (10BEx), 15 minutes after the operation (PO15), 30 minutes after the operation (PO30), 1 hour after the operation (PO1h) and 6 hours after the operation (PO6h). The pressure and compliance values were the same in groups 1 and 2. The pressure-time graphs for the two groups were different: in Group 2, MEP rose quickly at 10AEn and positive pressure values were seen in the middle ear. MEP then fell rapidly until the end of the surgery and lower and negative pressures (Mean -50 daPa) were observed at PO6h. In Group 1, MEP was elevated at 10AEn and positive pressure was found (but not as high as in Group 2). MEP then fell more slowly. In other words, positive pressure in the middle ear persisted longer and the middle ear was subjected to positive pressure and nitrogen over a longer period. Separate analyses were made in Groups 1 and 2 of pressure differences and of compliance values at eight measurement points using the Friedman test. Differences in pressure values were found to be statistically significant in both Group 1 (p = 0.000) and Group 2 (p = 0.000). In Group 1, all the 10AEn and 30AEn values were significantly higher than the PreO, PO30, PO1h and PO6h values. The 10BEx value was significantly higher than the PreO and PO1h values. The PO15 value was significantly higher than the PreO value. In Group 2, the PO6h value was significantly lower than the 10BEx, 10AEn and 30AEn values. The PO1h value was significantly lower than the 30AEn values. The MEP values increased in Group 1 in younger and taller children and in children receiving anaesthesia for shorter periods. MEP values increased in Group 2 in younger and taller children, and in heavier children. MEP values fell with the length of anaesthesia. In brief anaesthesia, nitrogen was not removed from the middle ear quickly in Group 1: middle ear pressure values were higher. The nitrous oxide remained in the middle ear longer and so the possibility of ear toxicity may increase. In Group 2, 50% O2 was rapidly absorbed and removed from the middle ear and so middle ear pressure was not as high. It may be concluded that air-oxygen mixture (Inspired O2 50%) anaesthesia should be recommended as being more reliable in tympanoplasties and other middle ear interventions than a N2O-O2 mixture (Inspired O2 30%).
Cheng, Zheng-Jun; Wang, Yun-Bing; Chen, Long; Gong, Jian-Ping; Zhang, Wei
2018-04-18
The aim of this meta-analysis is to compare the differences in postoperative markers of the hepatic function under different intra-abdominal pressures in laparoscopic cholecystectomy (LC). Several databases were searched for control studies, and then the weighted data were pooled with random-effect models. A total of 11 studies involving 865 patients were included. The meta-analysis reveals that the level of the aspartate aminotransferase and alanine transaminase of the low-pressure group has a lower postoperative increase than the moderate-pressure group (P<0.001). The level of the aspartate aminotransferase and alanine transaminase of the moderate-pressure group has a lower postoperative increase than the high-pressure group (P<0.001). Totally, the effect of lower pressure LC on postoperative hepatic functions is less significant than that of the higher one. Potential subgroup analysis does not modify these results. The recommended pressure in LC is suggested to be lower so as to result in a better surgical safety, especially for special populations.
NASA Technical Reports Server (NTRS)
Rinker, Martin; Krueger, Ronald; Ratcliffe, James
2013-01-01
The ground-air pressurization of lightweight honeycomb sandwich structures caused by alternating pressure differences between the enclosed air within the honeycomb core and the ambient environment is a well-known and controllable loading condition of aerospace structures. However, initial face sheet/core disbonds intensify the face sheet peeling effect of the internal pressure load significantly and can decrease the reliability of the sandwich structure drastically. Within this paper, a numerical parameter study was carried out to investigate the criticality of initial disbonds in honeycomb sandwich structures under ground-air pressurization. A fracture mechanics approach was used to evaluate the loading at the disbond front. In this case, the strain energy release rate was computed via the Virtual Crack Closure Technique. Special attention was paid to the pressure-deformation coupling which can decrease the pressure load within the disbonded sandwich section significantly when the structure is highly deformed.
Aksakal, Devrim; Hückstädt, Thomas; Richter, Steffen; Klitscher, Daniela; Wowra, Tobias; Schier, Felix; Wessel, Lucas M; Kubiak, Rainer
2016-11-01
Our previous work in a laparoscopic setting in piglets revealed that the systolic femoral artery pressure was approximately 5 % higher than its carotid counterpart, whereas the mean and diastolic values showed no significant difference. This remained idem when the intraabdominal pressure (IAP) was gradually increased. In this study, we aimed to investigate the effect of (1) intermittent IAP elevations and (2) a low cardiac output (CO) on the blood pressure (BP) difference cranially (carotid artery) and caudally (femoral artery) of a capnoperitoneum (ΔP = P a fem -P a carot ). A total of twenty-two piglets (mean body weight 11.0 kg; range 8.9-13.3 kg) were studied. Of these, 14 underwent intermittent IAP elevations at 8 and 16 mmHg, and ΔP was measured. In another 8 piglets, a model of reduced CO was created by introducing an air embolism (2 ml/kg over 30 s) in the inferior caval vein (VCI) at 12 mmHg IAP to further assess the influence of this variable on ΔP. Systolic ΔP remained at a mean of 5.6 mmHg and was not significantly affected by insufflation or exsufflation up to an IAP of 16 mmHg. Diastolic and mean values showed no differences between P a carot and P a fem . P a fem, systol remained higher than its carotid counterpart as long as the cardiac index (CI) was above 1.5 l/min/m 2 , but fell significantly below P a carot, systol at a low CI. There was no CO-dependent effect on diastolic and mean ΔP. Repeated IAP elevations do not significantly influence ΔP. Intermittent IAP elevations do not significantly influence ΔP. Despite of a CO-dependent inversion of systolic ΔP, mean BP measurements at the leg during laparoscopy remain representative even at low CO values.
Ransy, Doris G; Lord, Etienne; Caty, Martine; Lapointe, Normand; Boucher, Marc; Diallo, Abdoulaye Baniré; Soudeyns, Hugo
2018-04-17
Pregnancy is associated with modulations of maternal immunity that contribute to foeto-maternal tolerance. To understand whether and how these alterations impact antiviral immunity, a detailed cross-sectional analysis of selective pressures exerted on HIV-1 envelope amino-acid sequences was performed in a group of pregnant (n = 32) and non-pregnant (n = 44) HIV-infected women in absence of treatment with antiretroviral therapy (ART). Independent of HIV-1 subtype, p-distance, dN and dS were all strongly correlated with one another but were not significantly different in pregnant as compared to non-pregnant patients. Differential levels of selective pressure applied on different Env subdomains displayed similar yet non-identical patterns between the two groups, with pressure applied on C1 being significantly lower in constant regions C1 and C2 than in V1, V2, V3 and C3. To draw a general picture of the selection applied on the envelope and compensate for inter-individual variations, we performed a binomial test on selection frequency data pooled from pregnant and non-pregnant women. This analysis uncovered 42 positions, present in both groups, exhibiting statistically-significant frequency of selection that invariably mapped to the surface of the Env protein, with the great majority located within epitopes recognized by Env-specific antibodies or sites associated with the development of cross-reactive neutralizing activity. The median frequency of occurrence of positive selection per site was significantly lower in pregnant versus non-pregnant women. Furthermore, examination of the distribution of positively selected sites using a hypergeometric test revealed that only 2 positions (D137 and S142) significantly differed between the 2 groups. Taken together, these result indicate that pregnancy is associated with subtle yet distinctive changes in selective pressures exerted on the HIV-1 Env protein that are compatible with transient modulations of maternal immunity. Copyright © 2018 Elsevier B.V. All rights reserved.
Blais, P; Patel, A; Sayuk, G S; Gyawali, C P
2017-12-01
The upper esophageal sphincter (UES) reflexively responds to bolus presence within the esophageal lumen, therefore UES metrics can vary in achalasia. Within consecutive patients undergoing esophageal high-resolution manometry (HRM), 302 patients (58.2±1.0 year, 57% F) with esophageal outflow obstruction were identified, and compared to 16 asymptomatic controls (27.7±0.7 year, 56% F). Esophageal outflow obstruction was segregated into achalasia subtypes 1, 2, and 3, and esophagogastric junction outflow obstruction (EGJOO with intact peristalsis) using Chicago Classification v3.0. UES and lower esophageal sphincter (LES) metrics were compared between esophageal outflow obstruction and normal controls using univariate and multivariate analysis. Linear regression excluded multicollinearity of pressure metrics that demonstrated significant differences across individual subtype comparisons. LES integrated relaxation pressure (IRP) had utility in differentiating achalasia from controls (P<.0001), but no utility in segregating between subtypes (P=.27). In comparison to controls, patients collectively demonstrated univariate differences in UES mean basal pressure, relaxation time to nadir, recovery time, and residual pressure (UES-RP) (P≤.049). UES-RP was highest in type 2 achalasia (P<.0001 compared to other subtypes and controls). In multivariate analysis, only UES-RP retained significance in comparison between each of the subgroups (P≤.02 for each comparison). Intrabolus pressure was highest in type 3 achalasia; this demonstrated significant differences across some but not all subtype comparisons. Nadir UES-RP can differentiate achalasia subtypes within the esophageal outflow obstruction spectrum, with highest values in type 2 achalasia. This metric likely represents a surrogate marker for esophageal pressurization. © 2017 John Wiley & Sons Ltd.
Bergstrand, S; Källman, U; Ek, A-C; Engström, M; Lindgren, M
2015-08-01
The aim of this study was to explore the interaction between interface pressure, pressure-induced vasodilation, and reactive hyperaemia with different pressure-redistribution mattresses. A cross-sectional study was performed with a convenience sample of healthy young individuals, and healthy older individuals and inpatients, at a university hospital in Sweden. Blood flow was measured at depths of 1mm, 2mm, and 10mm using laser Doppler flowmetry and photoplethysmography. The blood flow, interface pressure and skin temperature were measured in the sacral tissue before, during, and after load while lying on one standard hospital mattress and three different pressure-redistribution mattresses. There were significant differences between the average sacral pressure, peak sacral pressure, and local probe pressure on the three pressure-redistribution mattresses, the lowest values found were with the visco-elastic foam/air mattress (23.5 ± 2.5mmHg, 49.3 ± 11.1mmHg, 29.2 ± 14.0mmHg, respectively). Blood flow, measured as pressure-induced vasodilation, was most affected in the visco-elastic foam/air group compared to the alternating pressure mattress group at tissue depths of 2mm (39.0% and 20.0%, respectively), and 10mm (56.9 % and 35.1%, respectively). Subjects in all three groups, including healthy 18-65 year olds, were identified with no pressure-induced vasodilation or reactive hyperaemia on any mattress (n=11), which is considered a high-risk blood flow response. Interface pressure magnitudes considered not harmful during pressure-exposure on different pressure-redistribution mattresses can affect the microcirculation in different tissue structures. Despite having the lowest pressure values compared with the other mattresses, the visco-elastic foam/air mattress had the highest proportion of subjects with decreased blood flow. Healthy young individuals were identified with the high-risk blood flow response, suggesting an innate vulnerability to pressure exposure. Furthermore, the evaluation of pressure-redistribution support surfaces in terms of mean blood flow during and after tissue exposure is not feasible, but assessment of pressure-induced vasodilation and reactive hyperaemia could be a new way to assess individualised physiological measurements of mechanisms known to be related to pressure ulcer development.
Associations of Region-Specific Foot Pain and Foot Biomechanics: The Framingham Foot Study
Hagedorn, Thomas J.; Dufour, Alyssa B.; Hannan, Marian T.
2015-01-01
Background. Specific regions of the foot are responsible for the gait tasks of weight acceptance, single-limb support, and forward propulsion. With region foot pain, gait abnormalities may arise and affect the plantar pressure and force pattern utilized. Therefore, this study’s purpose was to evaluate plantar pressure and force pattern differences between adults with and without region-specific foot pain. Methods. Plantar pressure and force data were collected on Framingham Foot Study members while walking barefoot at a self-selected pace. Foot pain was evaluated by self-report and grouped by foot region (toe, forefoot, midfoot, or rearfoot) or regions (two or three or more regions) of pain. Unadjusted and adjusted linear regression with generalized estimating equations was used to determine associations between feet with and without foot pain. Results. Individuals with distal foot (forefoot or toes) pain had similar maximum vertical forces under the pain region, while those with proximal foot (rearfoot or midfoot) pain had different maximum vertical forces compared to those without regional foot pain (referent). During walking, there were significant differences in plantar loading and propulsion ranging from 2% to 4% between those with and without regional foot pain. Significant differences in normalized maximum vertical force and plantar pressure ranged from 5.3% to 12.4% and 3.4% to 24.1%, respectively, between those with and without regional foot pain. Conclusions. Associations of regional foot pain with plantar pressure and force were different by regions of pain. Region-specific foot pain was not uniformly associated with an increase or decrease in loading and pressure patterns regions of pain. PMID:25995291
Kim, Sung-Jin; Yokokawa, Ryuji; Takayama, Shuichi
2012-12-03
This paper reveals a critical limitation in the electro-hydraulic analogy between a microfluidic membrane-valve (μMV) and an electronic transistor. Unlike typical transistors that have similar on and off threshold voltages, in hydraulic μMVs, the threshold pressures for opening and closing are significantly different and can change, even for the same μMVs depending on overall circuit design and operation conditions. We explain, in particular, how the negative values of the closing threshold pressures significantly constrain operation of even simple hydraulic μMV circuits such as autonomously switching two-valve microfluidic oscillators. These understandings have significant implications in designing self-regulated microfluidic devices.
Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production.
Williams, Monique; Talbot, Prue
2011-12-01
This study investigated the performance of electronic cigarettes (e-cigarettes), compared different models within a brand, compared identical copies of the same model within a brand, and examined performance using different protocols. Airflow rate required to generate aerosol, pressure drop across e-cigarettes, and aerosol density were examined using three different protocols. First 10 puff protocol: The airflow rate required to produce aerosol and aerosol density varied among brands, while pressure drop varied among brands and between the same model within a brand. Total air hole area correlated with pressure drop for some brands. Smoke-out protocol: E-cigarettes within a brand generally performed similarly when puffed to exhaustion; however, there was considerable variation between brands in pressure drop, airflow rate required to produce aerosol, and the total number of puffs produced. With this protocol, aerosol density varied significantly between puffs and gradually declined. CONSECUTIVE TRIAL PROTOCOL: Two copies of one model were subjected to 11 puffs in three consecutive trials with breaks between trials. One copy performed similarly in each trial, while the second copy of the same model produced little aerosol during the third trial. The different performance properties of the two units were attributed to the atomizers. There was significant variability between and within brands in the airflow rate required to produce aerosol, pressure drop, length of time cartridges lasted, and production of aerosol. Variation in performance properties within brands suggests a need for better quality control during e-cigarette manufacture.
Iriuchishima, Takanori; Tajima, Goro; Ingham, Sheila J M; Shen, Wei; Horaguchi, Takashi; Saito, Akiyoshi; Smolinski, Patrick; Fu, Freddie H
2009-06-01
Anterior cruciate ligament (ACL) graft impingement against the intercondylar roof has been postulated, but not thoroughly investigated. The roof impingement pressure changes with different tibial and femoral tunnel positions in ACL reconstruction. Anterior tibial translation is also affected by the tunnel positions of ACL reconstruction. The study design included a controlled laboratory study. In 15 pig knees, the impingement pressure between ACL and intercondylar roof was measured using pressure sensitive film before and after ACL single bundle reconstruction. ACL reconstructions were performed in each knee with two different tibial and femoral tunnel position combinations: (1) tibial antero-medial (AM) tunnel to femoral AM tunnel (AM to AM) and (2) tibial postero-lateral (PL) tunnel to femoral High-AM tunnel (PL to High-AM). Anterior tibial translation (ATT) was evaluated after each ACL reconstruction using robotic/universal force-moment sensor testing system. Neither the AM to AM nor the PL to High-AM ACL reconstruction groups showed significant difference when compared with intact ACL in roof impingement pressure. The AM to AM group had a significantly higher failure load than PL to High-AM group. This study showed how different tunnel placements affect the ACL-roof impingement pressure and anterior-posterior laxity in ACL reconstruction. Anatomical ACL reconstruction does not cause roof impingement and it has a biomechanical advantage in ATT when compared with non-anatomical ACL reconstructions in the pig knee. There is no intercondylar roof impingement after anatomical single bundle ACL reconstruction.
Horstman, Christopher L; Conzemius, Michael G; Evans, Richard; Gordon, Wanda J
2004-01-01
To document, using pressure platform gait analysis, the effect of perioperative oral carprofen on limb function and pain after cranial cruciate ligament surgery in dogs. Blinded, prospective clinical investigation. Twenty dogs with naturally occurring unilateral cranial cruciate disease. Physiologic indices, subjective pain scoring, and pressure platform gait analyses were performed before and 24, 48, and 72 hours after surgery. Correlations were assessed between methods of evaluation and the data was compared across treatment groups. No strong correlations were noted between physiologic data, subjective scoring systems, or gait analysis data at a walk or stance. Although average measures of limb function were nearly twice as large in dogs treated with carprofen, no significant differences between groups over time were identified. No significant differences were noted in any other measure of pain or limb function. Power analysis of peak vertical force at a walk indicated that significant difference would have been detected had the number of dogs in each group been increased to 35. When limb function was assessed with pressure platform gait analysis no statistical difference was noted between groups with respect to PVF and VI at a walk or stance, although average ground reaction forces for dogs in the carprofen group were greater than the traditional pain management group at all time points. Oral carprofen appears to provide some benefit for the treatment of postoperative orthopedic pain.
Xu, Baojun; Chang, Sam K C
2008-09-01
The effects of soaking, boiling and steaming processes on the total phenolic components and antioxidant activity in commonly consumed cool season food legumes (CSFL's), including green pea, yellow pea, chickpea and lentil were investigated. As compared to original unprocessed legumes, all processing steps caused significant (p<0.05) decreases in total phenolic content (TPC), DPPH free radical scavenging activity (DPPH) in all tested CSFL's. All soaking and atmospheric boiling treatments caused significant (p<0.05) decreases in oxygen radical absorbing capacity (ORAC). However, pressure boiling and pressure steaming caused significant (p<0.05) increases in ORAC values. Steaming treatments resulted in a greater retention of TPC, DPPH, and ORAC values in all tested CSFL's as compared to boiling treatments. To obtain cooked legumes with similar palatability and firmness, pressure boiling shortened processing time as compared to atmospheric boiling, resulted in insignificant differences in TPC, DPPH for green and yellow pea. However, TPC and DPPH in cooked lentils differed significantly between atmospheric and pressure boiling. As compared to atmospheric processes, pressure processes significantly increased ORAC values in both boiled and steamed CSFL's. Greater TPC, DPPH and ORAC values were detected in boiling water than that in soaking and steaming water. Boiling also caused more solid loss than steaming. Steam processing exhibited several advantages in retaining the integrity of the legume appearance and texture of the cooked product, shortening process time, and greater retention of antioxidant components and activities. Copyright © 2008 Elsevier Ltd. All rights reserved.
Accelerated decline of renal function in type 2 diabetes following severe hypoglycemia.
Tsujimoto, Tetsuro; Yamamoto-Honda, Ritsuko; Kajio, Hiroshi; Kishimoto, Miyako; Noto, Hiroshi; Hachiya, Remi; Kimura, Akio; Kakei, Masafumi; Noda, Mitsuhiko
2016-01-01
This study aimed to evaluate whether the pronounced elevation in blood pressure during severe hypoglycemia is associated with subsequent renal insufficiency. We conducted a 3-year cohort study to assess the clinical course of renal function in type 2 diabetes patients with or without blood pressure surge during severe hypoglycemia. Of 111 type 2 diabetes patients with severe hypoglycemia, 76 exhibited an extremely high systolic blood pressure before treatment, whereas 35 demonstrated no such increase (179.1 ± 27.7 mmHg vs. 131.1 ± 20.2 mmHg, P<0.001). At 12h after treatment, systolic blood pressure did not differ significantly (131.5 ± 30.7 mmHg vs. 123.5 ± 20.7 mmHg; P=0.39). The estimated glomerular filtration rate (GFR) before and at the time of severe hypoglycemia did not significantly differ between both groups. A multivariate Cox proportional hazards regression analysis revealed that blood pressure surge during severe hypoglycemia was independently associated with a composite outcome of a more than 15 mL/min/1.73 m(2) decrease in the estimated GFR and initiation of chronic dialysis (hazard ratio, 2.68; 95% confidence interval, 1.12-6.38; P=0.02). Renal function after severe hypoglycemia was significantly worse in type 2 diabetes patients with blood pressure surge during severe hypoglycemia than those without blood pressure surge. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Hassan, Nayera E; El Shebini, Salwa M; Ahmed, Nihad H; Selim Mostafa, Mohamed
2015-03-15
Study the association between the total caloric intake, protein, lipid, and some classes of fatty acids of the diet, and their effects on blood pressure in a sample of Egyptian obese women with and without visceral obesity. Five hundred forty-nine obese women were included in the study with mean age of 38.1 ± 11.56 years and mean Body mass index [BMI] of 36.17 ± 7.23. They enrolled in a program for losing weight. Visceral fat was determined using ultrasound. Blood pressure was measured 3 times and the mean was recorded. Twenty four hours dietary recall was reported. Thirty point four percentages of samples has visceral obesity ≥ 7cm; they were the older, showed higher values of BMI, visceral obesity and blood pressure. Significant difference was found between groups regarding mean value of BMI, visceral obesity, both systolic blood pressure SBP and diastolic blood pressure DBP and most of the daily macronutrients intake. In groups (2&3) positive significant correlation was recorded between (SBP) & (DBP) and total daily intake of total calories, carbohydrate, total fat, saturated fatty acids and cholesterol, and negative significant correlation with total daily intake of total protein, animal and vegetable protein, linolenic and linoleic fatty acids, while oleic fatty acid showed negative correlation with SBP&DBP in all groups. This study emphasizes the hypothesis that the macronutrients composition of diet influences blood pressure in different ways, in obese patients with visceral obesity.
Hassan, Nayera E.; El Shebini, Salwa M.; Ahmed, Nihad H.; Selim Mostafa, Mohamed
2015-01-01
AIM: Study the association between the total caloric intake, protein, lipid, and some classes of fatty acids of the diet, and their effects on blood pressure in a sample of Egyptian obese women with and without visceral obesity. METHODS: Five hundred forty-nine obese women were included in the study with mean age of 38.1 ± 11.56 years and mean Body mass index [BMI] of 36.17 ± 7.23. They enrolled in a program for losing weight. Visceral fat was determined using ultrasound. Blood pressure was measured 3 times and the mean was recorded. Twenty four hours dietary recall was reported. RESULTS: Thirty point four percentages of samples has visceral obesity ≥ 7cm; they were the older, showed higher values of BMI, visceral obesity and blood pressure. Significant difference was found between groups regarding mean value of BMI, visceral obesity, both systolic blood pressure SBP and diastolic blood pressure DBP and most of the daily macronutrients intake. In groups (2&3) positive significant correlation was recorded between (SBP) & (DBP) and total daily intake of total calories, carbohydrate, total fat, saturated fatty acids and cholesterol, and negative significant correlation with total daily intake of total protein, animal and vegetable protein, linolenic and linoleic fatty acids, while oleic fatty acid showed negative correlation with SBP&DBP in all groups. CONCLUSION: This study emphasizes the hypothesis that the macronutrients composition of diet influences blood pressure in different ways, in obese patients with visceral obesity. PMID:27275219
Brigatto, Patrícia; Carbinatto, Jéssica C.; Costa, Carolina M.; Montebelo, Maria I. L.; Rasera-Júnior, Irineu; Pazzianotto-Forti, Eli M.
2014-01-01
Objective: To evaluate whether the application of bilevel positive airway pressure in the postoperative period of bariatric surgery might be more effective in restoring lung volume and capacity and thoracic mobility than the separate application of expiratory and inspiratory positive pressure. Method: Sixty morbidly obese adult subjects who were hospitalized for bariatric surgery and met the predefined inclusion criteria were evaluated. The pulmonary function and thoracic mobility were preoperatively assessed by spirometry and cirtometry and reevaluated on the 1st postoperative day. After preoperative evaluation, the subjects were randomized and allocated into groups: EPAP Group (n=20), IPPB Group (n=20) and BIPAP Group (n=20), then received the corresponding intervention: positive expiratory pressure (EPAP), inspiratory positive pressure breathing (IPPB) or bilevel inspiratory positive airway pressure (BIPAP), in 6 sets of 15 breaths or 30 minutes twice a day in the immediate postoperative period and on the 1st postoperative day, in addition to conventional physical therapy. Results: There was a significant postoperative reduction in spirometric variables (p<0.05), regardless of the technique used, with no significant difference among the techniques (p>0.05). Thoracic mobility was preserved only in group BIPAP (p>0.05), but no significant difference was found in the comparison among groups (p>0.05). Conclusion: The application of positive pressure does not seem to be effective in restoring lung function after bariatric surgery, but the use of bilevel positive pressure can preserve thoracic mobility, although this technique was not superior to the other techniques. PMID:25590448
Effects of antihypertensive drugs on central blood pressure in humans: a preliminary observation.
Agnoletti, Davide; Zhang, Yi; Borghi, Claudio; Blacher, Jacques; Safar, Michel E
2013-08-01
Central blood pressure (BP) is considered a better predictor of cardiovascular events than brachial BP. Modifications of central, beyond brachial BP, can be assessed by pressure amplification, a potential new cardiovascular risk factor. Comparison between drugs' effect on central hemodynamics has been poorly studied. Our aim was to assess the hemodynamic effect of a 12-week treatment with amlodipine 5mg, or candesartan 8mg, or indapamide sustained-release 1.5mg, in comparison with placebo. We analyzed 145 out-patients with essential hypertension in primary prevention enrolled in the Natrilix SR Versus Candesartan and Amlodipine in the Reduction of Systolic Blood Pressure in Hypertensive Patients (X-CELLENT) study, a multicenter, randomized, double-blinded, placebo-controlled trial. Arterial stiffness, central BP, pressure amplification, and wave reflection were measured by applanation tonometry. Baseline characteristics of patients were homogeneous between groups. After treatment, we found that active drugs produced similar reduction of both central and peripheral BPs, with no significant interdrug differences (all P < 0.05; excluded peripheral pulse pressure, compared with placebo). Second, amlodipine (1.9% ± 15.3%), candesartan (3.0% ± 14.6%) and indapamide (4.1% ± 14.4%) all increased pulse pressure amplification, but only indapamide was statistically different from placebo (P = 0.02). Finally, no significant changes were observed on pulse wave velocity, heart rate, and augmentation index. The 3 antihypertensive drugs similarly reduced peripheral and central BP, as compared with placebo, but a significant increase in pulse pressure amplification was obtained only with indapamide, independently of arterial stiffness modifications. 3283161 by BIOPHARMA.
Decision making under time pressure, modeled in a prospect theory framework.
Young, Diana L; Goodie, Adam S; Hall, Daniel B; Wu, Eric
2012-07-01
The current research examines the effects of time pressure on decision behavior based on a prospect theory framework. In Experiments 1 and 2, participants estimated certainty equivalents for binary gains-only bets in the presence or absence of time pressure. In Experiment 3, participants assessed comparable bets that were framed as losses. Data were modeled to establish psychological mechanisms underlying decision behavior. In Experiments 1 and 2, time pressure led to increased risk attractiveness, but no significant differences emerged in either probability discriminability or outcome utility. In Experiment 3, time pressure reduced probability discriminability, which was coupled with severe risk-seeking behavior for both conditions in the domain of losses. No significant effects of control over outcomes were observed. Results provide qualified support for theories that suggest increased risk-seeking for gains under time pressure.
Thermodynamics of a Magnetic Transition in MnS2 at High Pressures
NASA Astrophysics Data System (ADS)
Sidorov, V. A.; Guo, Jing; Sun, Liling; Brazhkin, V. V.
2018-03-01
The behavior of the specific heat of MnS2 at high pressures has been studied. A significant increase in the transition temperature T N to an antiferromagnetic state with the pressure from 48.2 K at atmospheric pressure to 76 K at a pressure of 5.3 GPa has been revealed. The initial pressure derivative is dT N / dP = 4.83 K/GPa. It has been found that the parameter α = d(log T N )/ d(log V ) = -6.6 ± 0.1 is significantly different from the value α = -10/3 ≈ -3.3 (Bloch relation), which is typical of numerous antiferromagnetic insulators—transition- metal oxides and fluorides. The volume jump at the magnetic transition point has been estimated. The necessity of direct dilatometric measurements of the volume has been justified.
Decision making under time pressure, modeled in a prospect theory framework
Young, Diana L.; Goodie, Adam S.; Hall, Daniel B.; Wu, Eric
2012-01-01
The current research examines the effects of time pressure on decision behavior based on a prospect theory framework. In Experiments 1 and 2, participants estimated certainty equivalents for binary gains-only bets in the presence or absence of time pressure. In Experiment 3, participants assessed comparable bets that were framed as losses. Data were modeled to establish psychological mechanisms underlying decision behavior. In Experiments 1 and 2, time pressure led to increased risk attractiveness, but no significant differences emerged in either probability discriminability or outcome utility. In Experiment 3, time pressure reduced probability discriminability, which was coupled with severe risk-seeking behavior for both conditions in the domain of losses. No significant effects of control over outcomes were observed. Results provide qualified support for theories that suggest increased risk-seeking for gains under time pressure. PMID:22711977
[Features of arterial blood pressure in elderly persons of different ethnic groups in Yakutsk].
Nikitin, Iu P; Tatarinova, O V; Neustroeva, V N; Shcherbakova, L V; Sidorov, A S
2013-01-01
The differences in arterial blood pressure in the sample of population in the age of 60 and older of different ethnic groups in Yakutsk, as well as its connection with the other cardiovascular diseases risk factors have been analyzed. It was shown that the average values of systolic and diastolic blood pressure in subsample of the Yakuts appeared to be lower than in Caucasoid gerontic persons. The average values of systolic arterial blood pressure both in the Yakuts and in the Caucasoids were detected higher than normal values in all age-dependent subgroups. The average values of diastolic blood pressure in both ethnic groups were within the limits of high normal level. From 60 to 90 years and older the decrease in systolic and diastolic arterial blood pressure was detected; it was more marked in Caucasoid gerontic persons. The average values of pulse pressure in the Yakuts and in the Caucasoids appeared to be higher than the existing standard and didn't have any differences in ethnic groups. In both ethnical subsamples, pulse pressure values increase was observed in persons of 60-89 years old and its decrease after 90. Persons with overweight, obesity, central (abdominal) obesity, dyslypoproteidemias irrespective of belonging to ethnical group were characterized as having higher levels of arterial blood pressure. Statistically significant differences in the levels of arterial blood pressure in the Yakuts and in the Caucasoids depending on hyperglycemia, smoking, the presence of burdened anamnesis, educational level, marital status was not detected.
Uusitupa, M; Tuomilehto, J; Karttunen, P; Wolf, E
1984-01-01
A double-blind, placebo-controlled trial was carried out in 17 Type 2 (non-insulin-dependent) diabetic patients, treated with diet therapy alone to study the effects of guar gum on metabolic control, serum lipids, and blood pressure levels. Thirteen of the patients had drug treatment for hypertension. Guar gum was taken with meals three times a day, and the dose was gradually increased to 21 g per day. A slight, but not significant improvement was found in the metabolic control of the patients after the guar gum treatment compared to the placebo. Serum total cholesterol was 11% (p greater than 0.01) lower after the guar gum but no significant differences were found in HDL-cholesterol or serum triglycerides during the guar gum treatment compared to the placebo. Diastolic blood pressure level was significantly lower during the guar gum treatment compared to placebo. No difference was observed in systolic blood pressure levels between the guar gum and placebo treatments. The reduction of diastolic blood pressure was independent of changes in fasting blood glucose level or body weight, but could in part be due to simultaneous reduction in serum cholesterol concentration. The changes associated with guar gum supplementation suggest a reduction in the risk for cardiovascular complications in diabetic patients.
Palmar pressure distribution during push-up exercise.
Chuckpaiwong, B; Harnroongroj, T
2009-07-01
Doing repetitive push-ups is among the most common exercise for the upper body and shoulder stabiliser muscle strength training. However, adverse effects such as neck pain, back pain, palmar pain and wrist pain have been reported. To date, to our knowledge, palmar pressure when performing push-ups has not been previously reported. We hypothesised that various hand positions during push-ups may provide different palmar pressures. Bilateral palmar pressures were recorded in ten individual volunteers. All the subjects were set up for doing push-ups in five positions of the hand. Peak palmar pressure was recorded by Emed pressure platform system (Novel GmBH, Munich, Germany). The palm was divided into the following five anatomic regions, viz. thenar, lunate, hypothenar, metacarpals and fingers. Statistical comparison between the five positions of the hand was analysed using the analysis of variance test. A distribution of the mean peak pressure of the lunate and hypothenar areas were relatively higher than the other areas in both standby and full-elbow flexion positions. At the palmar position 30 cm wider than the shoulder width, the palmar pressure revealed significantly higher peak pressure in the lunate area in the standby and fully-flexed elbow positions (p-value is less than 0.05). At the palmar position 10 cm narrower than the shoulder width, palmar pressure showed significantly higher peak pressure in the hypothenar area only in the fully-flexed elbow position. The information regarding palmar pressures while performing push-ups in different hand positions may be used as a guideline for exercise modification, especially in injured athletes.
Xie, Zhiyi; Zhang, Zhenyu; Xu, Yuan; Zhou, Hua; Wu, Sheng; Wang, Zhong
2018-06-01
In this prospective observational study, we investigated the variability in radial artery invasive blood pressure associated with arm elevation in patients with different hemodynamic types. We carried out a prospective observational study using data from 73 general anesthesia hepatobiliary postoperative adult patients admitted to an ICU over a 1-year period. A standard procedure was used for the arm elevation test. The value of invasive radial arterial pressure was recorded at baseline, and 30 and 60 s after the arm had been raised from 0° to 90°. We compared the blood pressure before versus after arm elevation, and between hemodynamically stable, hypovolemic shock, and septic shock patient groups. In all 73 patients, systolic arterial pressure (SAP) decreased, diastolic arterial pressure (DAP) increased, and pulse pressure (PP) decreased at 30 and 60 s after arm elevation (P<0.01), but the mean arterial pressure (MAP) was unchanged (P>0.05). On comparing 30 and 60 s, there was no significant difference in SAP, DAP, PP, or MAP (P>0.05). In 40 hemodynamically stable patients, SAP and PP decreased, and DAP and MAP increased significantly at 30 and 60 s after arm elevation compared with baseline (P<0.01). In 16 hypovolemic patients, SAP, DAP, and MAP increased significantly compared with baseline at 30 and 60 s (P<0.01), but PP was unchanged (P>0.05). In 17 patients with septic shock, SAP, PP, and MAP decreased significantly versus baseline at 30 and 60 s (P<0.01), but DAP was unchanged (P>0.05). Comparison of the absolute value of pressure change of septic shock patients at 30 s after raising the arm showed that SAP, DAP, and MAP changes were significantly lower compared with those in hypovolemic shock and hemodynamically stable patients (P<0.01). The areas under the receiver operator characteristic curve for predicting septic shock was 0.930 [95% confidence interval (CI): 0.867-0.992, P< 0.001] for change value at 30 s after arm elevation of SAP. The best cut-off point for the SAP change value was -5 mmHg or less, with a sensitivity of 94.12%, a specificity of 80.36%, a positive likelihood ratio of 4.79 (95% CI: 2.8-8.2), and a negative likelihood ratio of 0.073 (95% CI: 0.01-0.5). Our study shows that hypovolemic shock and septic shock patients have significantly different radial artery invasive blood pressure changes in an arm elevation test, which could be applied as a new method to distinguish hypovolemic shock and septic shock from hypotension.
Different characteristics of circular staplers make the difference in anastomotic tensile strength.
Giaccaglia, V; Antonelli, M S; Franceschilli, L; Salvi, P F; Gaspari, A L; Sileri, P
2016-01-01
Anastomotic leak after gastrointestinal surgery is a severe complication associated with relevant short and long-term sequelae. Most of the anastomoses are currently performed with a surgical stapler that is required to have appropriate characteristics in order to guarantee good performances. The aim of our study was to evaluate, ex vivo, pressure resistance and tensile strength of anastomosis performed with different circular staplers available in the market. We studied 7 circular staplers of 3 different companies, 3 of them used for gastrointestinal anastomosis and 4 staplers for hemorrhoidal prolapse excision. A total of 350 anastomoses, 50 for each of the 7 staplers, were performed using healthy pig fresh intestine, then injected saline solution and recorded the leaking pressure. There were no statistically significant differences between the mean pressure necessary to induce an anastomotic leak in the various instruments (p>0.05). For studying tensile strength, we performed a total of 350 anastomoses with 7 different circular staplers on a special strong paper (Tyvek), and then recorded the maximal tensile force that could open the anastomosis. There were statistically significant differences between one brand stapler vs other 2 companies staplers about the strength necessary to open the staple line (p<0.05). In conclusion, we demonstrated that different circular staplers of three companies available in the market give comparable anastomotic pressure resistance but different tensile strengths. This is probably due to different technical characteristics. Copyright © 2015 Elsevier Ltd. All rights reserved.
Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H
2009-01-01
The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.
Siváková, Daniela; Lajdová, Alica; Basistová, Zuzana; Cvícelová, Marta; Karabová, Patrícia; Blazícek, Pavel
2008-06-01
Epidemiological studies have demonstrated that several specific environmental factors and candidate genes influence the human variation in blood pressure. The aim of this study was to investigate variables associated with blood pressure; with a particular emphasis on the differences in insertion/deletion (I/D) polymorphism of the human angiotensin-converting enzyme (ACE), the body composition and the recognized risk factors for atherosclerosis among elderly males and females. A total of 374 participants (174 males and 200 females) aged from 60 to 90 years were recruited from different parts of Slovakia. The elderly were not bed-ridden, nor mentally impaired, they were able to manage their daily activities by themselves. The ACE I/D polymorphism was determined by PCR amplification of the ACE gene sequence. Body composition variables were obtained by bioelectrical impedance analysis, using the BIA 101 soft tissue-body impedance analyzer (Akern, S.r.l.). The subjects were determined to be hypertensive (blood pressure > or = 140/90 mm Hg) or normotensive (blood pressure < or = 140/90 mm Hg ). These two subgroups of males and females did not differ significantly in their mean ages. As expected, the hypertensive subjects of both sexes showed significantly higher mean values in systolic (SBP) and diastolic blood pressure (DBP), in body mass index (BMI), and in the mean values of their plasma glucose and extracellular water (ECW). The genotype distribution and allele frequencies in the whole sample (D = 0.5474, I = 0.4526) fell within the Hardy-Weinberg equilibrium. The frequency of the deleterious D allele in the normotensive (0.5532) and hypertensive (0.5516) subjects was not significantly different. The ACE I/D genotypes did not associate either with the systolic (p = 0.836) or diastolic BP (p = 0.629). From the other variables that may induce differences in blood pressure, a statistical effect was detected for glucose, Na/K, and Apo A1/ApoB ratios and physical activity on SBP, and for ApoA1, physical activity, BMI and total cholesterol on DBP.
Variations in plantar pressure variables across five cardiovascular exercises.
Burnfield, Judith M; Jorde, Amy G; Augustin, Tanner R; Augustin, Tate A; Bashford, Gregory R
2007-11-01
To quantify variations in plantar pressure variables in healthy adults across five cardiovascular exercises. Ten young (19-35 yr old) and 10 middle-aged (45-60 yr old) individuals participated. After equipment familiarization, plantar pressure data were recorded during walking, running, elliptical training, stair climbing, and recumbent biking. Separate one-way analyses of variance with repeated measures identified significant differences in pressure variables across exercises and between age groups under the forefoot, arch, and heel. Forefoot: Peak pressures were higher during walking (253 kPa), running (251 kPa), and elliptical training (213 kPa) than stair climbing (130 kPa) and recumbent biking (41 kPa; P < or = 0.001). Biking pressures were lower than all other conditions (P < 0.001). Arch: Pressures were higher during running (144 kPa) compared with all other conditions (P < or = 0.001). Intermediate-level pressures during walking (119 kPa) and elliptical training (102 kPa) exceeded those during stair climbing (80 kPa; P < or = 0.002). Pressures were lowest during recumbent biking (33 kPa; P < 0.001). Heel: Pressures were highest during walking (215 kPa) and running (188 kPa), exceeding those recorded during all other activities (P < 0.001). Moderate elliptical training pressures (94 kPa) surpassed stair climbing values (66 kPa; P = 0.014). Pressures were lowest during recumbent biking (25 kPa; P < 0.001). The only significant difference identified between age groups was a larger arch contact area in the young compared with middle-aged, when averaged across exercises (P = 0.011). When protection of the forefoot is important (e.g., diabetic foot neuropathies), biking and stair climbing offer optimal pressure reductions. If protecting the heel from high pressures and forces is warranted, recumbent biking, stair climbing, and elliptical training provide greater relief.
The Volumetric Diversity of Misfolded Prion Protein Oligomers Revealed by Pressure Dissociation*
Torrent, Joan; Lange, Reinhard; Rezaei, Human
2015-01-01
Protein oligomerization has been associated with a wide range of diseases. High pressure approaches offer a powerful tool for deciphering the underlying molecular mechanisms by revealing volume changes associated with the misfolding and assembly reactions. We applied high pressure to induce conformational changes in three distinct β-sheet-rich oligomers of the prion protein PrP, a protein characterized by a variety of infectious quaternary structures that can propagate stably and faithfully and cause diseases with specific phenotypic traits. We show that pressure induces dissociation of the oligomers and leads to a lower volume monomeric PrP state that refolds into the native conformation after pressure release. By measuring the different pressure and temperature sensitivity of the tested PrP oligomers, we demonstrate significantly different void volumes in their quaternary structure. In addition, by focusing on the kinetic and energetic behavior of the pressure-induced dissociation of one specific PrP oligomer, we reveal a large negative activation volume and an increase in both apparent activation enthalpy and entropy. This suggests a transition state ensemble that is less structured and significantly more hydrated than the oligomeric state. Finally, we found that site-specific fluorescent labeling allows monitoring of the transient population of a kinetic intermediate in the dissociation reaction. Our results indicate that defects in atomic packing may deserve consideration as a new factor that influences differences between PrP assemblies and that could be relevant also for explaining the origin of prion strains. PMID:26126829
van Anholt, R D; Sobotka, L; Meijer, E P; Heyman, H; Groen, H W; Topinková, E; van Leen, M; Schols, J M G A
2010-09-01
We investigated the potential of a high-protein, arginine- and micronutrient-enriched oral nutritional supplement (ONS) to improve healing of pressure ulcers in non-malnourished patients who would usually not be considered for extra nutritional support. Forty-three non-malnourished subjects with stage III or IV pressure ulcers were included in a multicountry, randomized, controlled, double-blind, parallel group trial. They were offered 200 mL of the specific ONS or a non-caloric control product three times per day, in addition to their regular diet and standard wound care, for a maximum of 8 wk. Results were compared with repeated-measures mixed models (RMMM), analysis of variance, or Fisher's exact tests for categorical parameters. Supplementation with the specific ONS accelerated pressure ulcer healing, indicated by a significantly different decrease in ulcer size compared with the control, over the period of 8 wk (P
[Trends in the prevalence of pressure ulcers in an acute care tertiary hospital (2006-2013)].
Alonso-Lorente, C; Barrasa-Villar, J I; Aibar-Remón, C
2015-01-01
To analyse the trends in pressure ulcer prevalence from 2006 to 2013. To determine the main risk factors associated with pressure ulcers. A descriptive study analysing the prevalence in a series of pressure ulcers collected in the study on the prevalence of nosocomial infections in Spain from 2006 to 2013 in the Clinical University Hospital of Zaragoza. The mean prevalence among the 5,354 patients included over the period of study was 4.5% (95% CI=3.9-5.0%). No significant difference in its trend or distribution of pressure ulcers was observed over the several years of the study. Prevalence increased up to 5.0% (95% CI=4.4-5.6%) when short-stay patients (less than 24 hours) and those admitted into low risk units (Paediatrics, Psychiatry and Obstetrics) were removed from the study, but there was still no significant differences in its yearly trend or distribution (p>0.05). Age, length of stay, presence of coma, in-dwelling urethral catheters, malnutrition, infection, and admission unit were risk factors associated with pressure ulcer prevalence in the logistic regression. Age, length of stay, coma, in-dwelling urethral catheters, malnutrition, infection, and admission unit were independent risk markers for patients with pressure ulcers. No particular trend of pressure ulcer prevalence could be determined to demonstrate any effects from the different strategies of improvement implemented during the period of study, although this fact could be due to the limitations of data used in the study. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
Dehghan, Habibollah; Bastami, Mohamad Taghi; Mahaki, Behzad
2017-01-01
Exposure to noise and heat causes individuals to experience some changes in the function of cardiovascular system in workplaces. This study aimed to find the combined effect of heat and noise on systolic and diastolic types of blood pressure in experimentally controlled conditions. This quasi-experimental study was performed with 12 male students in a climatic chamber in 2014. Blood pressure including systolic and diastolic was measured in the following conditions: 15 min after rest in exposure to heat (40°C, relative humidity [RH]: 30%), exposure to noise with 75, 85, and 95 dB rates in thermal comfort condition (22.1 ± 0.9 wet-bulb globe temperature), and combined exposure to heat (40°C, RH: 30%) and noise with 75, 85, and 95 dB. Friedman test was used to analyze the data. The mean change of systolic blood pressure was different significantly before and after exposure to heat and noise levels including 75, 85, and 95 dB ( P = 0.015, P = 0.001, P > 0.001, P = 0.027, respectively). Although systolic and diastolic blood pressures changed drastically, it was not significantly different in simultaneous exposure to heat and noise. Both systolic and diastolic blood pressures decreased in exposure to heat, while exposure to different levels of noise elevates systolic and diastolic blood pressures. However, when exposed to a combination of heat and noise, subtle changes of blood pressure were traced, which can be characterized as average, considering heat-only and noise-only tension situations.
Hu, Jihong; Zhao, Liancheng; Thompson, Brian; Zhang, Yawei; Wu, Yangfeng
2018-02-05
It is known that home blood pressure (HBP) is a more reliable assessment of hypertension treatments than clinical blood pressure (BP). Despite this, HBP response to a salt substitute has only been evaluated by one study which, did not look at the salt substitute's effect on family members and did not analyze by age, gender, or BP degree. The aim of this current study was to assess the effects of a low-sodium and high-potassium salt substitute on HBP among hypertensive patients and their family members. A total of 220 households (including 220 hypertensive patients and 380 their families) were randomly assigned to the regular salt or salt substitute groups. HBP was measured at the beginning, 3rd, 6th, and 12th months. Among the patients (n = 220), only home systolic blood pressure (HSBP) was significantly reduced, by an adjusted baseline BP of 4.2 mm Hg (95% CI: 1.3-7.0 mm Hg), in the salt substitute group compared with those in the regular salt group at each visit (all P < 0.05). There were no detectable differences between groups for home diastolic blood pressure (HDBP) at any visit. Among the family members, HSBP and HDBP were not significantly different between the groups. Furthermore, Individuals ≥60 years old, hypertensive patients with stage-2 hypertension, family members with hypertension, and women experienced greater HSBP reduction. Older subjects, those with higher blood pressure, and women experienced greater home blood pressure reduction from the salt substitute compared to regular salt.
Does blood pressure variability affect the summer associated symptoms amongst females?
Sinha, Pragya; Singh, N P; Taneja, D K; Sah, Renuka
2010-04-01
Blood pressure usually increases in winter and decreases in summer i.e, shows seasonal variation. In a tropical country like India women often complain off prominent symptoms like dizziness, giddiness, fainting and weakness during summer months. The objective was to study the prevalence of above symptoms which are common during summer and its association with variation in blood pressure among normotensive healthy females aged 18-40 years. The present study was carried out on 132 women as a prospective observational study which included 2 home visits to the participants in the two different seasons in the months of May-June (summer) and December-January (winter) based on the data provided by the meteorological department of Government of India. Blood pressure and pulse rate (hemodynamic variables) was measured in these seasons and information was collected on the occurrence of the symptoms in these seasons. There was mean decrease of 11.07 +/- 10.29 mm of Hg in Systolic blood pressure & 6.79 +/-6.88 mm of Hg in diastolic blood pressure in summer as compared to winter. The symptoms in the form of weakness, dizziness and blackout which are generally perceived by women in this area to be due to low blood pressure were observed in 32.6% of the study subjects in summer compared with 2.3% in winter. The difference was statistically highly significant (p < 0.001). There was no significant difference between the mean value of electrolytes, creatinine and urea in the cases and the controls. Thus the seasonal variation in blood pressure rather than electrolytes abnormality may be responsible for these symptoms.
Noise exposure and children's blood pressure and heart rate: the RANCH project
van Kempen, E; Van Kamp, I; Fischer, P; Davies, H; Houthuijs, D; Stellato, R; Clark, C; Stansfeld, S
2006-01-01
Background Conclusions that can be drawn from earlier studies on noise and children's blood pressure are limited due to inconsistent results, methodological problems, and the focus on school noise exposure. Objectives To investigate the effects of aircraft and road traffic noise exposure on children's blood pressure and heart rate. Methods Participants were 1283 children (age 9–11 years) attending 62 primary schools around two European airports. Data were pooled and analysed using multilevel modelling. Adjustments were made for a range of socioeconomic and lifestyle factors. Results After pooling the data, aircraft noise exposure at school was related to a statistically non‐significant increase in blood pressure and heart rate. Aircraft noise exposure at home was related to a statistically significant increase in blood pressure. Aircraft noise exposure during the night at home was positively and significantly associated with blood pressure. The findings differed between the Dutch and British samples. Negative associations were found between road traffic noise exposure and blood pressure, which cannot be explained. Conclusion On the basis of this study and previous scientific literature, no unequivocal conclusions can be drawn about the relationship between community noise and children's blood pressure. PMID:16728500
Ozcan, Ayse; Tulum, Zeliha; Pinar, Lamia; Başkurt, Ferdi
2004-12-01
This study was done to evaluate differences in pressure pain threshold, grip strength, manual dexterity and touch pressure threshold in the dominant and non-dominant hands of right- and left-handed subjects, and to compare findings within and between these groups. Thirty-nine right-handed and twenty-one left-handed subjects participated in the study. Pressure pain threshold was assessed using a dolorimeter, grip strength was assessed with a hand-grip dynamometer, manual dexterity was evaluated using the VALPAR Component Work Sample-4 system, and touch pressure threshold was determined using Semmes Weinstein monofilaments. Results for the dominant and non-dominant hands were compared within and between the groups. In the right-handed subjects, the dominant hand was significantly faster with the VALPAR Component Work Sample-4, showed significantly greater grip strength, and had a significantly higher pressure pain threshold than the non-dominant hand. The corresponding results for the two hands were similar in the left-handed subjects. The study revealed asymmetrical manual performance in grip strength, manual dexterity and pressure pain threshold in right-handed subjects, but no such asymmetries in left-handed subjects.
Impaired Central Pulsatile Hemodynamics in Children and Adolescents With Marfan Syndrome.
Grillo, Andrea; Salvi, Paolo; Marelli, Susan; Gao, Lan; Salvi, Lucia; Faini, Andrea; Trifirò, Giuliana; Carretta, Renzo; Pini, Alessandro; Parati, Gianfranco
2017-11-07
Marfan syndrome is characterized by aortic root dilation, beginning in childhood. Data about aortic pulsatile hemodynamics and stiffness in pediatric age are currently lacking. In 51 young patients with Marfan syndrome (12.0±3.3 years), carotid tonometry was performed for the measurement of central pulse pressure, pulse pressure amplification, and aortic stiffness (carotid-femoral pulse wave velocity). Patients underwent an echocardiogram at baseline and at 1 year follow-up and a genetic evaluation. Pathogenetic fibrillin-1 mutations were classified between "dominant negative" and "haploinsufficient." The hemodynamic parameters of patients were compared with those of 80 sex, age, blood pressure, and heart-rate matched controls. Central pulse pressure was significantly higher (38.3±12.3 versus 33.6±7.8 mm Hg; P =0.009), and pulse pressure amplification was significantly reduced in Marfan than controls (17.9±15.3% versus 32.3±17.4%; P <0.0001). Pulse wave velocity was not significantly different between Marfan and controls (4.98±1.00 versus 4.75±0.67 m/s). In the Marfan group, central pulse pressure and pulse pressure amplification were independently associated with aortic diameter at the sinuses of Valsalva (respectively, β=0.371, P =0.010; β=-0.271, P =0.026). No significant difference in hemodynamic parameters was found according to fibrillin-1 genotype. Patients who increased aortic Z-scores at 1-year follow-up presented a higher central pulse pressure than the remaining (42.7±14.2 versus 32.3±5.9 mm Hg; P =0.004). Central pulse pressure and pulse pressure amplification were impaired in pediatric Marfan syndrome, and associated with aortic root diameters, whereas aortic pulse wave velocity was similar to that of a general pediatric population. An increased central pulse pressure was present among patients whose aortic dilatation worsened at 1-year follow-up. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Fernando, Malindu Eranga; Crowther, Robert George; Pappas, Elise; Lazzarini, Peter Anthony; Cunningham, Margaret; Sangla, Kunwarjit Singh; Buttner, Petra; Golledge, Jonathan
2014-01-01
Elevated dynamic plantar pressures are a consistent finding in diabetes patients with peripheral neuropathy with implications for plantar foot ulceration. This meta-analysis aimed to compare the plantar pressures of diabetes patients that had peripheral neuropathy and those with neuropathy with active or previous foot ulcers. Published articles were identified from Medline via OVID, CINAHL, SCOPUS, INFORMIT, Cochrane Central EMBASE via OVID and Web of Science via ISI Web of Knowledge bibliographic databases. Observational studies reporting barefoot dynamic plantar pressure in adults with diabetic peripheral neuropathy, where at least one group had a history of plantar foot ulcers were included. Interventional studies, shod plantar pressure studies and studies not published in English were excluded. Overall mean peak plantar pressure (MPP) and pressure time integral (PTI) were primary outcomes. The six secondary outcomes were MPP and PTI at the rear foot, mid foot and fore foot. The protocol of the meta-analysis was published with PROPSERO, (registration number CRD42013004310). Eight observational studies were included. Overall MPP and PTI were greater in diabetic peripheral neuropathy patients with foot ulceration compared to those without ulceration (standardised mean difference 0.551, 95% CI 0.290-0.811, p<0.001; and 0.762, 95% CI 0.303-1.221, p = 0.001, respectively). Sub-group analyses demonstrated no significant difference in MPP for those with neuropathy with active ulceration compared to those without ulcers. A significant difference in MPP was found for those with neuropathy with a past history of ulceration compared to those without ulcers; (0.467, 95% CI 0.181- 0.753, p = 0.001). Statistical heterogeneity between studies was moderate. Plantar pressures appear to be significantly higher in patients with diabetic peripheral neuropathy with a history of foot ulceration compared to those with diabetic neuropathy without a history of ulceration. More homogenous data is needed to confirm these findings.
Odili, Augustine N; Abdullahi, Bolaji; Nwankwo, Adaku M; Asayama, Kei; Staessen, Jan A
2015-10-01
We investigated the characteristics of self-measured home blood pressure (HBP) in a randomly selected population of Nigerians living in Abuja, Nigeria. HBP was the average of 28 measurements comprising duplicate morning and evening readings obtained over a 7-day period by the participants using a semiautomated oscillometric device. Blood pressure measured five consecutive times by trained observers using mercury sphygmomanometer was averaged as the office blood pressure (OBP). Among the 337 participants included in the analysis, 46.6% were women and their mean age (SD) 40.3 (11.3). The mean, mean+2 SD and 95th percentile of HBP and OBP were 117/76, 147/96 and 145/93 mmHg and 114/73, 147/97 and 142/73 mmHg, respectively. The corresponding values in normotensive individuals were 113/73, 137/89 and 132/88 mmHg and 108/70, 130/88 and 128/84 mmHg. Morning HBPs were significantly higher than that of the evening, with a mean difference (confidence interval) of 1.8 mmHg (1.1-2.5 mmHg) and 1.9 mmHg (1.4-2.3 mmHg) for systolic and diastolic pressures, respectively (P<0.0001). There is a strong correlation between the office and home systolic (r=0.8, P<0.0001) and diastolic (r=0.7, P<0.0001) pressures. Overall, the HBP values were significantly higher than OBP, with a mean difference (confidence interval) of systolic/diastolic of 3.6 mmHg (2.5-4.6 mmHg)/2.3 mmHg (1.4-3.1 mmHg) (P<0.0001). The HBP/OBP difference was maintained in men and normotensive individuals, but in women and hypertensive participants, there was no significant difference between HBP and OBP. Our findings have shown that self-measured blood pressure is feasible and can be used to evaluate blood pressure outside the clinic environment among Nigerians.
Pelletier, Cathy A; Steele, Catriona M
2014-02-01
This study examined whether the perceived taste intensity of liquids with chemesthetic properties influenced lingua-palatal pressures and submental surface electromyography (sEMG) in swallowing, compared with water. Swallowing was studied in 80 healthy women, stratified by age group and genetic taste status. General Labeled Magnitude Scale ratings of taste intensity were collected for deionized water; carbonated water; 2.7% w/v citric acid; and diluted ethanol. These stimuli were swallowed, with measurement of tongue-palate pressures and submental sEMG. Path analysis differentiated stimulus, genetic taste status, age, and perceived taste intensity effects on swallowing. Signal amplitude during effortful saliva swallowing served as a covariate representing participant strength. Significant differences (p < .05) in taste intensity were seen across liquids: citric acid > ethanol > carbonated water > water. Supertasters perceived greater taste intensity than did nontasters. Lingua-palatal pressure and sEMG amplitudes were correlated with the strength covariate. Anterior palate pressures and sEMG amplitudes were significantly higher for the citric acid stimulus. Perceived taste intensity was a significant mediator of stimulus differences. These data provide confirmatory evidence that high-intensity sour stimuli do influence swallowing behaviors. In addition, taste genetics influence the perception of taste intensity for stimuli with chemesthetic properties, which modulates behavioral responses.
Semplicini, A; Ambrosio, G B; Rigon, E; Dissegna, L; Zamboni, S; Rossi, G; Pessina, A C; Dal Palù, C
1985-12-01
An increase in intra-erythrocytic sodium (IENa) content has been proposed as a genetic marker of essential hypertension. Intra-erythrocytic sodium was studied using hypotonic lysis and flame photometry after four washings with isotonic MgCl2 in 240 normotensive subjects (aged 10-45 years) on a free diet with (F+, 121 patients) or without (F-, 119 patients) hypertensive parents, recruited from a random sample of the general population. Systolic blood pressure was significantly higher in males F+ than in males F- (130 +/- 2 versus 125 +/- 2 mmHg, mean +/- s.e.m., P < 0.05), while IENa did not differ. In contrast, intra-erythrocytic potassium content (IEK) was significantly lower and red cell sodium potassium (Na:K) ratio significantly higher in F+ than F-. This might reflect decreased NaK pump activity, or increased membrane permeability to cations which causes increased K leakage. No differences in blood pressure, IENa or IEK showed in female F+ versus F-. It is concluded that IENa is not a genetic marker of hypertension, and that it is probably influenced by exogenous factors. Being associated with differences in blood pressure, the abnormalities of IEK and Na:K ratio might be pathogenetically linked to an early increase in blood pressure.
Elrazek, E Abd
2004-10-01
The aim of this prospective, randomized and crossover study was to assess the role of a relatively new mode of mechanical ventilation, biphasic intermittent positive airway pressure (BIPAP) in comparison to another well established one, pressure-support ventilation (PSV) in surgical intensive care patients. 24 generally stable patients, breathing on their own after short-term (< 24 hours) postoperative controlled mechanical ventilation (CMV) were randomized to start on either PSV or BIPAP, and indirect calorimetry measurements were performed after 1 hour adaptation period at two time intervals; immediately after the investigated ventilatory mode was started and 1 hour later. Statistics included a two-tailed paired t-test to compare the two sets of different data, p < 0.5 was considered significant. Oxygen consumption (VO2), energy expenditure (EE), Carbon dioxide production (VCO2), and respiratory quotient (RQ) did not differ significantly between the two groups. There were also no significant differences regarding respiratory rate (RR), minute volume (MV) and arterial blood gas analysis (ABGs). Both modes of ventilation were well tolerated by all patients. PSV and BIPAP can be used for weaning patients comfortably in surgical intensive care after short-term postoperative ventilation. BIPAP may have the credit of being smoother than PSV where no patient effort is required.
Davis, Brian; Crow, Mariam; Berki, Visar; Ciltea, Daniela
2017-02-08
To assess dynamic arch support in diabetic patients at risk for Charcot neuroarthopathy whose arch index has not yet shown overt signs of foot collapse. Two indirect measures of toe flexor activation (ratios: peak hallux pressure to peak metatarsal pressure - Ph/Pm; peak posterior hallux shear to peak posterior metatarsal shear - Sh/Sm) were obtained with a custom built system for measuring shear and pressure on the plantar surface of the foot during gait. In addition, the tendency of the longitudinal arch to flatten was measured by quantifying the difference in shear between the 1st metatarsal head and the heel (S flatten ) during the first half of the stance phase. Four stance phases from the same foot for 29 participants (16 control and 13 neuropathic diabetic) were assessed. The peak load ratio under the hallux (Ph/Pm) was significantly higher in the control group (2.10±1.08 versus 1.13±0.74, p=0.033). Similarly, Sh/Sm was significantly higher in the control group (1.87±0.88 versus 0.88±0.45, p=0.004). The difference in anterior shear under the first metatarsal head and posterior shear under the lateral heel (S flatten ) was significantly higher in the diabetic group (p<0.01). Together these findings demonstrate reduced plantar flexor activity in the musculature responsible for maintaining the longitudinal arch. With no significant difference in arch index between the two groups, but significant differences in Ph/Pm, Sh/Sm and S flatten the collective results suggest there are changes in muscle activity that precede arch collapse. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gender differences in left ventricular function in patients with isolated aortic stenosis.
Favero, Luca; Giordan, Massimo; Tarantini, Giuseppe; Ramondo, Angelo Bruno; Cardaioli, Paolo; Isabella, Giambattista; Chioin, Raffaello; Lupia, Mario; Razzolini, Renato
2003-05-01
Hypertrophic response of the left ventricle to systolic overload in aortic stenosis appears to be gender-dependent. To examine gender-related differences in left ventricular (LV) function in patients with isolated severe aortic stenosis, 145 patients (65 women, 80 men; mean age 66 +/- 8 years; range: 50 to 89 years) with aortic valve area <0.8 cm2 who underwent cardiac catheterization were studied. No patient had associated myocardial, coronary or other valve disease; patients with diabetes mellitus and systemic hypertension were excluded. No significant differences were seen in aortic valve area between men and women. Neither were there any significant gender-related differences in LV end-systolic and end-diastolic volumes, LV end-diastolic pressure, LV mass indexed by body surface area, LV mass:volume ratio, LV mass:height ratio, elastic stiffness constant, ejection fraction, pulmonary wedge pressure, pulmonary arteriolar resistance and preload. Women showed significantly higher mean transaortic gradient, LV peak systolic pressure and peak systolic stress, end-systolic stress:end-systolic volume ratio, heart rate and cardiac index. In the subgroup of patients with LV pressure >199 mmHg, the mass:volume ratio was increased in men compared with women; of note, the mass:volume ratio in women was not increased in this subgroup compared with the general population. LV pump function in this subgroup was normal and did not differ between men and women. Although no clear-cut difference in hemodynamic parameters was seen, there was a trend towards a less compensatory increase in LV mass in females.
Plantar pressure of clipless and toe-clipped pedals in cyclists - A pilot study
Davis, Andrea; Pemberton, Troy; Ghosh, Subhajit; Maffulli, Nicola; Padhiar, Nat
2011-01-01
Summary To determine the effect of clipless and toe-clipped pedals on plantar foot pressure while cycling. Seven bikers and 11 healthy volunteers were tested on a Giant ATX Team mountain bike, Tekscan Clinical 5.24 F-scan® system with an inner sole pressure sensor, a Tacx Cycle force One Turbo Trainer and a Cateye Mity 8 computerized speedometer were used. The subjects wore Shimano M037 shoes and used a standard clipless and toe-clipped pedal. The seat height was set at 100% of subject’s trochanteric height. Plantar pressures were recorded over 12 consecutive crank cycles at a constant speed for each of the power outputs. The videos were analysed to record the pressure exerted at 12 positions on the foot for each variable. Whether there is any dominance of any of the metatarsals, and any difference in plantar pressures between clipped and clipless pedal. There was a significant difference in the pressure at many positions of the foot, but the sites were different for each individual. General regression analysis indicated that pedal type had a statistically significant effect on plantar pressure at the sites of 1st metatarsal (p=0.042), 3rd metatarsal (p<0.001), 5th metatarsal (<0.001), 2nd (p=0.018) and 5th toe (p<0.001), lateral midfoot (p<0.001) and central heel (p<0.001) areas. Clipless pedals produce higher pressures which are more spread across the foot than toe-clipped pedals. This may have implications for their use in the prevention and/or management of overuse injuries in the knee and foot. PMID:23738240
Yano, Yuichiro; Sato, Yuji; Fujimoto, Shouichi; Konta, Tsuneo; Iseki, Kunitoshi; Moriyama, Toshiki; Yamagata, Kunihiro; Tsuruya, Kazuhiko; Yoshida, Hideaki; Asahi, Koichi; Kurahashi, Issei; Ohashi, Yasuo; Watanabe, Tsuyoshi
2012-01-01
OBJECTIVE To examine whether there is a difference in the association between high pulse pressure and proteinuria, independent of other blood pressure (BP) indices, such as systolic or diastolic BP, among subjects with diabetes, prediabetes, or normal glucose tolerance. RESEARCH DESIGN AND METHODS Using a nationwide health checkup database of 228,778 Japanese aged ≥20 years (mean 63.2 years; 39.3% men; none had pre-existing cardiovascular disease), we examined the association between high pulse pressure, defined as the highest quintile of pulse pressure (≥63 mmHg, n = 40,511), and proteinuria (≥1+ on dipstick, n = 12,090) separately in subjects with diabetes (n = 27,913), prediabetes (n = 100,214), and normal glucose tolerance (n = 100,651). RESULTS The prevalence of proteinuria was different among subjects with diabetes, prediabetes, and normal glucose tolerance (11.3 vs. 5.0 vs. 3.9%, respectively; P < 0.001). In subjects with diabetes, but not those with prediabetes or normal glucose tolerance, high pulse pressure was associated with proteinuria independently of significant covariates, including systolic BP (odds ratio 1.15 [95% CI 1.04–1.28]) or diastolic or mean BP (all P < 0.01). In patients with diabetes, a +1 SD increase of pulse pressure (+13 mmHg) was associated with proteinuria, even after adjustment for systolic BP (1.07 [1.00–1.13]) or diastolic or mean BP (all P < 0.05). CONCLUSIONS Among the Japanese general population, there was a significant difference in the association between high pulse pressure and proteinuria among subjects with diabetes, prediabetes, and normal glucose tolerance. Only in diabetes was high pulse pressure associated with proteinuria independent of systolic, diastolic, or mean BP levels. PMID:22474041
Tanaka, M; Ikeda, S; Nakayama, F
1981-06-01
Duodenoscopic manometry of the pancreatic duct (PD) and common bile duct (CBD) using a microtransducer catheter was distinct advantages over infusion manometry, giving absolute values of in situ intraluminal pressure. Microtransducer manometry was performed without medication in 49 patients with gallbladder stones (10), common bile duct stones (24), hepatic duct stones (6) and common bile duct dilatation (9), and was successful in 42 (86%) for PD and 36 (73%) for CBD. Ductal pressures showed respiration-synchronized biphasic variations superimposed by the arterial pulsation effect. Considerable postural change of the pressure values suggested that the recording posture should be predetermined. The PD-to-duodenum pressure gradient was higher than the CBD-to-duodenum gradient in most cases. Both were lower than those obtained previously by infusion methods. No significant differences were found in pressure profiles of the four disease groups. Endoscopic sphincterotomy significantly reduced not only CBD pressure but also PD pressure.
Garner, Rochelle E; Levallois, Patrick
2017-05-01
Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Men had higher mean systolic (114.8 vs. 110.8mmHg, p<0.01) and diastolic (74.0 vs. 69.6mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70mmHg, 95% confidence interval [CI]=0.25-1.16, p<0.01) and diastolic blood pressure (0.74mmHg, 95% CI=0.30-1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44-0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32-0.85, p=0.01). This study provides evidence of a significant association between cadmium levels, blood pressure and hypertension. However, the significance and direction of this association differs by sex, smoking status, and body mass index category. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Kim, Haroo; Kak, Hwang-Bo; Kim, Boin
2014-01-01
[Purpose] The purpose of this study was to compare the effect of childbirth delivery method on vaginal pressure and abdominal thickness during the Valsalva maneuver (VAL). [Subjects] Thirty healthy female volunteers (26–39 years of age) were selected for this research. Their delivery histories were: nulliparous 10, vaginal delivery 10, and Cesarean delivery 10. None of the participants had a history of incontinence. [Methods] In the crook-lying position, a perineometer probe was inserted into the vagina and the transducer was placed transversely on the right side of the body during the Valsalva maneuver. [Results] There were significant differences in the thickness of the transverses abdominis (TrA) between in all the groups rest and the Valsalva maneuver, and there were significant differences in the internus oblique (IO) in the nulliparous group. During the Valsalva maneuver, there were significant differences in the TrA between the nulliparous group and the vaginal delivery group, and there were significant differences in the IO between the nulliparous delivery group and the vaginal delivery group, and between the nulliparous group and the Cesarean section group. Delivery history changed vaginal pressure, and there were significant differences between the nulliparous group and the vaginal delivery group, and between the nulliparous group and the Cesarean delivery group. [Conclusion] Pregnancy and delivery method may affect pelvic floor and abdominal muscles during the Valsalva maneuver. PMID:24707104
ERIC Educational Resources Information Center
Kosmidou, Evdoxia; Giannitsopoulou, Evgenia; Moysidou, Dimitra
2017-01-01
Participation in sports may influence negative body image and Social Physique Anxiety (SPA) as there is pressure by significant others to have a certain body image. The aim of the present study was to examine possible differences in SPA and perceived pressure to be thin between female preadolescent and adolescent ballet dancers, rhythmic…
Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T
2015-10-01
Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.
Yang, Hui; Zhou, Yan; Lin, Jin
2016-01-01
Background While appropriate pillow height is crucial to maintaining the quality of sleep and overall health, there are no universal, evidence-based guidelines for pillow design or selection. We aimed to evaluate the effect of pillow height on cranio-cervical pressure and cervical spine alignment. Methods Ten healthy subjects (five males) aged 26 ± 3.6 years were recruited. The average height, weight, and neck length were 167 ± 9.3 cm, 59.6 ± 11.9 kg, and 12.9 ± 1.2 cm respectively. The subjects lay on pillows of four different heights (H0, 110 mm; H1, 130 mm; H2, 150 mm; and H3, 170 mm). The cranio-cervical pressure distribution over the pillow was recorded; the peak and average pressures for each pillow height were compared by one-way ANOVA with repeated measures. Cervical spine alignment was studied using a finite element model constructed based on data from the Visible Human Project. The coordinate of the center of each cervical vertebra were predicted for each pillow height. Three spine alignment parameters (cervical angle, lordosis distance and kyphosis distance) were identified. Results The average cranial pressure at pillow height H3 was approximately 30% higher than that at H0, and significantly different from those at H1 and H2 (p < 0.05). The average cervical pressure at pillow height H0 was 65% lower than that at H3, and significantly different from those at H1 and H2 (p < 0.05). The peak cervical pressures at pillow heights H2 and H3 were significantly different from that at H0 (p < 0.05). With respect to cervical spine alignment, raising pillow height from H0 to H3 caused an increase of 66.4% and 25.1% in cervical angle and lordosis distance, respectively, and a reduction of 43.4% in kyphosis distance. Discussion Pillow height elevation significantly increased the average and peak pressures of the cranial and cervical regions, and increased the extension and lordosis of the cervical spine. The cranio-cervical pressures and cervical spine alignment were height-specific, and they were believed to reflect quality of sleep. Our results provide a quantitative and objective evaluation of the effect of pillow height on the biomechanics of the head-neck complex, and have application in pillow design and selection. PMID:27635354
Pu, Fang; Ren, Weiyan; Fu, Hongyuan; Zheng, Xuan; Yang, Min; Jan, Yih-Kuen; Fan, Yubo
2018-05-11
The aim of this study was to investigate the plantar blood flow response to the same accumulated pressure stimulus in diabetic patients with different peak plantar pressure (PPP), which is important for assessing the risk of diabetic foot ulcer. Eleven diabetic subjects with high PPP (PPP ≥ 207 kPa) and 8 diabetic subjects with low PPP (PPP < 207 kPa) were asked to walk naturally on a treadmill so as to induce an accumulated stimulus of 73,000 kPa·s on their first metatarsal head, which was monitored with a sensorized insole. Blood perfusion (BP) in the first metatarsal head was measured before and after walking. Results showed that blood flow after applying the same walking stimulus was significantly decreased in comparison to the basal BP before walking in both high PPP and low PPP groups (p < 0.05), but no significant differences were found between the two groups in terms of BP parameters and its percentage change (p > 0.05). Moreover, BP parameters were not significantly correlated to PPP and the pressure-time integral (PTI) of the subjects' gait (p > 0.05). This indicated that, besides PPP and PTI, the accumulated mechanical stimulus should be taken into consideration when assessing the risk of diabetic patients developing foot ulcers. Graphical abstract Plantar blood flow response to a walking stimulus.
Nemer, Sérgio Nogueira; Caldeira, Jefferson B; Santos, Ricardo G; Guimarães, Bruno L; Garcia, João Márcio; Prado, Darwin; Silva, Ricardo T; Azeredo, Leandro M; Faria, Eduardo R; Souza, Paulo Cesar P
2015-12-01
To verify whether high positive end-expiratory pressure levels can increase brain tissue oxygen pressure, and also their effects on pulse oxygen saturation, intracranial pressure, and cerebral perfusion pressure. Twenty traumatic brain injury patients with acute respiratory distress syndrome were submitted to positive end-expiratory pressure levels of 5, 10, and 15 cm H2O progressively. The 3 positive end-expiratory pressure levels were used during 20 minutes for each one, whereas brain tissue oxygen pressure, oxygen saturation, intracranial pressure, and cerebral perfusion pressure were recorded. Brain tissue oxygen pressure and oxygen saturation increased significantly with increasing positive end-expiratory pressure from 5 to 10 and from 10 to 15 cm H2O (P=.0001 and P=.0001 respectively). Intracranial pressure and cerebral perfusion pressure did not differ significantly with increasing positive end-expiratory pressure from 5 to 10 and from 10 to 15 cm H2O (P=.16 and P=.79 respectively). High positive end-expiratory pressure levels increased brain tissue oxygen pressure and oxygen saturation, without increase in intracranial pressure or decrease in cerebral perfusion pressure. High positive end-expiratory pressure levels can be used in severe traumatic brain injury patients with acute respiratory distress syndrome as a safe alternative to improve brain oxygenation. Copyright © 2015 Elsevier Inc. All rights reserved.
A comparative study of slow and fast suryanamaskar on physiological function
Bhavanani, Ananda Balayogi; Udupa, Kaviraja; Madanmohan; Ravindra, PN
2011-01-01
Background: Numerous scientific studies have reported beneficial physiological changes after short- and long-term yoga training. Suryanamaskar (SN) is an integral part of modern yoga training and may be performed either in a slow or rapid manner. As there are few studies on SN, we conducted this study to determine the differential effect of 6 months training in the fast and slow versions. Materials and Methods: 42 school children in the age group of 12–16 years were randomly divided into two groups of 21 each. Group I and Group II received 6 months training in performance of slow suryanamaskar (SSN) and fast suryanamaskar (FSN), respectively. Results: Training in SSN produced a significant decrease in diastolic pressure. In contrast, training in FSN produced a significant increase in systolic pressure. Although there was a highly significant increase in isometric hand grip (IHG) strength and hand grip endurance (HGE) in both the groups, the increase in HGE in FSN group was significantly more than in SSN group. Pulmonary function tests showed improvements in both the groups though intergroup comparison showed no significance difference. Maximum inspiratory pressure (MIP) and maximum expiratory pressure increased significantly in both the groups with increase of MIP in FSN group being more significant than in SSN. Conclusion: The present study reports that SN has positive physiological benefits as evidenced by improvement of pulmonary function, respiratory pressures, hand grip strength and endurance, and resting cardiovascular parameters. It also demonstrates the differences between SN training when performed in a slow and fast manner, concluding that the effects of FSN are similar to physical aerobic exercises, whereas the effects of SSN are similar to those of yoga training. PMID:22022125
Martín-Espinosa, Noelia; Díez-Fernández, Ana; Sánchez-López, Mairena; Rivero-Merino, Irene; Lucas-De La Cruz, Lidia; Solera-Martínez, Montserrat; Martínez-Vizcaíno, Vicente
2017-01-01
The prevalence of high blood pressure in children is increasing worldwide, largely, but not entirely, driven by the concurrent childhood obesity epidemic. The aims of this study were to examine the prevalence of prehypertension and hypertension in 4-to-6-year-old Spanish schoolchildren, and to evaluate the association between different blood pressure (BP) components with different adiposity indicators. Cross-sectional study including a sample of 1.604 schoolchildren aged 4-to-6-years belonging to 21 schools from the provinces of Ciudad Real and Cuenca, Spain. We measured height, weight, body mass index (BMI), fat mass percentage (%FM), triceps skinfold thickness (TST), waist circumference (WC), systolic and diastolic BP, mean arterial pressure and pulse pressure. The estimates of prevalence of prehypertension and hypertension were 12.3% and 18.2%, respectively. In both sexes, adiposity indicators were positively and significantly associated with all BP components (p<0.001), thus schoolchildren in the higher adiposity categories had significantly higher BP levels (p<0.001). Our results show a high prevalence of high blood pressure in Spanish children. Moreover, high levels of adiposity are associated with high blood pressure in early childhood, which support that it could be related to cardiovascular risk later in life.
[Pulmonary function of children with acute leukemia in maintenance phase of chemotherapy].
de Macêdo, Thalita Medeiros Fernandes; Campos, Tania Fernandes; Mendes, Raquel Emanuele de França; França, Danielle Corrêa; Chaves, Gabriela Suéllen da Silva; de Mendonça, Karla Morganna Pereira Pinto
2014-12-01
The aim of this study was to assess the pulmonary function of children with acute leukemia. Cross-sectional observational analytical study that enrolled 34 children divided into groups A (17 with acute leukemia in the maintenance phase of chemotherapy) and B (17 healthy children). The groups were matched for sex, age and height. Spirometry was measured using a spirometer Microloop Viasys(®) in accordance with American Thoracic Society and European Respiratory Society guidelines. Maximal respiratory pressures were measured with an MVD300 digital manometer (Globalmed(®)). Maximal inspiratory pressures and maximal expiratory pressures were measured from residual volume and total lung capacity, respectively. Group A showed a significant decrease in maximal inspiratory pressures when compared to group B. No significant difference was found between the spirometric values of the two groups, nor was there any difference between maximal inspiratory pressure and maximal expiratory pressure values in group A compared to the lower limit values proposed as reference. Children with acute leukemia, myeloid or lymphoid, during the maintenance phase of chemotherapy exhibited unchanged spirometric variables and maximal expiratory pressure; However, there was a decrease in inspiratory muscle strength. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Shafik, A
1995-07-01
The role of the bulbocavernosus (BC) and ischiocavernosus (IC) muscles in erection and ejaculation was studied. The response of the urethral and intracorporeal pressure to cavernosus muscle stimulation was evaluated in 18 male volunteers (mean age, 36.6 years). A two-channel microtip catheter was placed in the prostatic and bulbous urethra. Muscle stimulation was done by two needle electrodes inserted into the BC and IC muscles. BC muscle stimulation caused an increase in the pressure of the bulbous urethra (P < 0.001) and corpus spongiosum (P < 0.01) and an insignificant change in the prostatic and pendulous urethral and corpus cavernosal pressures (difference not significant). IC muscle stimulation effected an increase in the corpus cavernosal pressure (P < 0.001) without changing the urethral pressure (difference not significant). The BC muscle contracts rhythmically at orgasm and this might help to eject the semen from the posterior to the anterior urethra. It is apparent that the muscle has minimal or no role in erection. IC muscle may have a role in erection by increasing the intracavernosal pressure. It seems that it has no role in ejaculation. BC may be considered the "muscle of ejaculation," and IC the "muscle of erection."
Martín-Espinosa, Noelia; Díez-Fernández, Ana; Sánchez-López, Mairena; Rivero-Merino, Irene; Lucas-De La Cruz, Lidia; Solera-Martínez, Montserrat; Martínez-Vizcaíno, Vicente
2017-01-01
Background The prevalence of high blood pressure in children is increasing worldwide, largely, but not entirely, driven by the concurrent childhood obesity epidemic. The aims of this study were to examine the prevalence of prehypertension and hypertension in 4-to-6-year-old Spanish schoolchildren, and to evaluate the association between different blood pressure (BP) components with different adiposity indicators. Methods Cross-sectional study including a sample of 1.604 schoolchildren aged 4-to-6-years belonging to 21 schools from the provinces of Ciudad Real and Cuenca, Spain. We measured height, weight, body mass index (BMI), fat mass percentage (%FM), triceps skinfold thickness (TST), waist circumference (WC), systolic and diastolic BP, mean arterial pressure and pulse pressure. Results The estimates of prevalence of prehypertension and hypertension were 12.3% and 18.2%, respectively. In both sexes, adiposity indicators were positively and significantly associated with all BP components (p<0.001), thus schoolchildren in the higher adiposity categories had significantly higher BP levels (p<0.001). Conclusions Our results show a high prevalence of high blood pressure in Spanish children. Moreover, high levels of adiposity are associated with high blood pressure in early childhood, which support that it could be related to cardiovascular risk later in life. PMID:28141860
Pan, Fan; He, Peiyu; Liu, Chengyu; Li, Taiyong; Murray, Alan; Zheng, Dingchang
2017-11-01
Korotkoff sounds are known to change their characteristics during blood pressure (BP) measurement, resulting in some uncertainties for systolic and diastolic pressure (SBP and DBP) determinations. The aim of this study was to assess the variation of Korotkoff sounds during BP measurement by examining all stethoscope sounds associated with each heartbeat from above systole to below diastole during linear cuff deflation. Three repeat BP measurements were taken from 140 healthy subjects (age 21 to 73 years; 62 female and 78 male) by a trained observer, giving 420 measurements. During the BP measurements, the cuff pressure and stethoscope signals were simultaneously recorded digitally to a computer for subsequent analysis. Heartbeats were identified from the oscillometric cuff pressure pulses. The presence of each beat was used to create a time window (1 s, 2000 samples) centered on the oscillometric pulse peak for extracting beat-by-beat stethoscope sounds. A time-frequency two-dimensional matrix was obtained for the stethoscope sounds associated with each beat, and all beats between the manually determined SBPs and DBPs were labeled as "Korotkoff." A convolutional neural network was then used to analyze consistency in sound patterns that were associated with Korotkoff sounds. A 10-fold cross-validation strategy was applied to the stethoscope sounds from all 140 subjects, with the data from ten groups of 14 subjects being analyzed separately, allowing consistency to be evaluated between groups. Next, within-subject variation of the Korotkoff sounds analyzed from the three repeats was quantified, separately for each stethoscope sound beat. There was consistency between folds with no significant differences between groups of 14 subjects (P = 0.09 to P = 0.62). Our results showed that 80.7% beats at SBP and 69.5% at DBP were analyzed as Korotkoff sounds, with significant differences between adjacent beats at systole (13.1%, P = 0.001) and diastole (17.4%, P < 0.001). Results reached stability for SBP (97.8%, at sixth beat below SBP) and DBP (98.1%, at sixth beat above DBP) with no significant differences between adjacent beats (SBP P = 0.74; DBP P = 0.88). There were no significant differences at high-cuff pressures, but at low pressures close to diastole there was a small difference (3.3%, P = 0.02). In addition, greater within subject variability was observed at SBP (21.4%) and DBP (28.9%), with a significant difference between both (P < 0.02). In conclusion, this study has demonstrated that Korotkoff sounds can be consistently identified during the period below SBP and above DBP, but that at systole and diastole there can be substantial variations that are associated with high variation in the three repeat measurements in each subject.
Ambulatory blood pressure monitoring in healthy children with parental hypertension.
Alpay, Harika; Ozdemir, Nihal; Wühl, Elke; Topuzoğlu, Ahmet
2009-01-01
The aim of this study was to compare ambulatory blood pressure monitoring (ABPM) parameters in offspring with at least one hypertensive parent (HP) to offspring with normotensive parents (NP) and to determine whether gender of parent or child might influence the association between parental hypertension and blood pressure (BP). Eighty-nine healthy children (mean age 11.1 +/- 3.9 years) with HP and 90 controls (mean age 10.5 +/- 3.1 years) with NP were recruited. Age, gender, and height did not differ between the two groups, whereas children of HP had higher weight, body mass index (BMI), and waist circumference compared with healthy controls. No difference was found in casual BP between the two groups. In contrast, during ABPM daytime and nighttime mean systolic and diastolic BP and mean arterial pressure (MAP) standard deviation scores (SDS) were significantly elevated in children with HP. The mean percentage of nocturnal BP decline (dipping) was not significantly different between the two groups. Children with hypertensive mothers had higher daytime systolic and MAP SDS than controls; no such difference was detected for children with hypertensive fathers. Daytime systolic and MAP SDS were significantly elevated in boys with HP compared with boys with NP but failed to be significant in girls. Multiple linear regression analysis showed that parental history of hypertension (B = 0.29) and BMI (B = 0.03) were independently correlated with increase of daytime MAP SDS. Early changes in ambulatory BP parameters were present in healthy children of HP. BP in HP offspring was influenced by the gender of the affected parent and the offspring.
NASA Astrophysics Data System (ADS)
Lin, Cong; Wang, Bo; Xu, Zheng; Peng, Hu
2012-11-01
ZnO varistors were prepared by microwave sintering under different oxygen partial pressures. The temperature profile and the densification behavior in different atmospheres were investigated. It was found that the density of ZnO varistors during sintering was the key factor affecting the absorption of microwave energy. The electrical properties, including the nonlinear properties and capacitance-voltage ( C- V) characteristics, were also carefully studied. The results showed that the oxygen partial pressure has significant effects on the electrical properties of ZnO varistors by changing the concentration of defects through a series of reactions involving oxygen during sintering.
Effects of body position and sex group on tongue pressure generation.
Dietsch, Angela M; Cirstea, Carmen M; Auer, Ed T; Searl, Jeff P
2013-11-01
Fine control of orofacial musculature is necessary to precisely accelerate and decelerate the articulators across exact distances for functional speech and coordinated swallows (Amerman & Parnell, 1990; Benjamin, 1997; Kent, Duffy, Slama, Kent, & Clift, 2001). Enhanced understanding of neural control for such movements could clarify the nature of and potential remediation for some dysarthrias and other orofacial myofunctional impairments. Numerous studies have measured orolingual force and accuracy during speech and nonspeech tasks, but have focused on young adults, maximum linguapalatal pressures, and upright positioning (O'Day, Frank, Montgomery, Nichols, & McDade, 2005; Solomon & Munson, 2004; Somodi, Robin, & Luschei, 1995; Youmans, Youmans, & Stierwalt, 2009). Patients' medical conditions or testing procedures such as concurrent neuroimaging may preclude fully upright positioning during oral motor assessments in some cases. Since judgments about lingual strength and coordination can influence clinical decisions regarding the functionality of swallowing and speech, it is imperative to understand any effects of body positioning differences. In addition, sex differences in the control of such tasks are not well defined. Therefore, this study evaluated whether pressures exerted during tongue movements differ in upright vs. supine body position in healthy middle-aged men and women. Twenty healthy middle-aged adults compressed small air-filled plastic bulbs in the oral cavity at predetermined fractions of task-specific peak pressure in a randomized block design. Tasks including phoneme repetitions and nonspeech isometric contractions were executed in upright and supine positions. Participants received continuous visual feedback regarding targets and actual exerted pressures. Analyses compared average pressure values for each subject, task, position, and effort level. Speech-like and nonspeech tongue pressures did not differ significantly across body position or sex groups. Pressure matching was significantly less accurate at higher percentages of maximum pressure for both tasks. These results provide preliminary comparative data for the clinical assessment of individuals with orofacial myofunctional and neurological disorders.
Comparative in vitro flow study of 3 different Ex-PRESS miniature glaucoma device models.
Estermann, Stephan; Yuttitham, Kanokwan; Chen, Julie A; Lee, On-Tat; Stamper, Robert L
2013-03-01
To determine the flow characteristics of the 3 different models of the Ex-PRESS miniature glaucoma device in a controlled laboratory study. The 3 different Ex-PRESS models (P-50, R-50, and P-200; Optonol Ltd; now Alcon Lab) were tested using a gravity-driven flow test. Three samples of each of the 3 Ex-PRESS models were subjected to a constant gravitational force of fluid at 5 different pressure levels (5 to 25 mm Hg). Four measurements per sample were taken at each pressure level. The main outcome measure was flow rate (Q) (µL/min). Resistance (R) was calculated by dividing pressure (P) by the measured flow (Q). The flow rate was primarily pressure dependent. The P-200 model (internal diameter 200 µm) showed a statistically significant higher flow rate and lower resistance compared with both the P-50 and R-50 models (internal diameter 50 µm) (P<0.0001). The P-50 and R-50 models demonstrated similar flow rates (P=0.08) despite their difference in tube length (2.64 vs. 2.94 mm). The 3 models of the Ex-PRESS mini shunt behaved in vitro as simple flow resistors by creating a relatively constant resistance to flow. Tube diameter was the only parameter with significant impact on flow and resistance. All models demonstrated flow rates per unit of pressure much higher than the outflow facility of a healthy human eye.
Elgebaly, Ahmed Said
2017-01-01
Background: Respiratory failure is of concern in the postoperative period after cardiac surgeries. Invasive ventilation (intermittent positive pressure ventilation [IPPV]) carries the risks and complications of intubation and mechanical ventilation (MV). Aims: Noninvasive positive pressure ventilation (NIPPV) is an alternative method and as effective as IPPV in treating insufficiency of respiration with less complications and minimal effects on respiratory and hemodynamic parameters next to open-heart surgery. Design: This is a prospective, randomized and controlled study. Materials and Methods: Forty-four patients scheduled for cardiac surgery were divided into two equal groups: Group I (IPPV) and Group II (NIPPV). Heart rate (HR), mean arterial pressure (MAP), respiratory rate (RR), oxygen saturation (SpO2), arterial blood gas, weaning time, reintubation, tracheotomy rate, MV time, postoperative hospital stay, and ventilator-associated pneumonia during the period of hospital stay were recorded. Results: There was statistically significant difference in HR between groups with higher in Group I at 30 and 60 min and at 12 and 24 h. According to MAP, it started to increase significantly at hypoxemia, 15 min, 30 min, 4 h, 12 h, and at 24 h which was higher in Group I also. RR, PaO2, and PaCO2 showed significant higher in Group II at 15, 30, and 60 min and 4 h. According to pH, there was a significant difference between groups at 15, 30, and 60 min and at 4, 12, and 24 h postoperatively. SpO2 showed higher significant values in Group I at 15 and 30 min and at 12 h postoperatively. Duration of postoperative supportive ventilation was higher in Group I than that of Group II with statistically significant difference. Complications were statistically insignificant between Group I and Group II. Conclusion: Our study showed superiority of invasive over noninvasive mode of ventilator support. However, NIPPV (bilevel positive airway pressure) was proved to be a safe method. PMID:28994676
Borg, Jael; Mizzi, Stephen; Formosa, Cynthia
2018-05-19
Clinicians currently rely on observational clinical data pertaining to the biomechanics of the diabetic foot. However, advances in technology can objectively describe this. A thorough understanding of the functional and mechanical consequences following trans-tibial amputations is lacking. Does a trans-tibial prostheses significantly increase peak plantar pressures and pressure time integrals in the intact foot of patients with type-2 diabetes and neuropathy? A prospective quantitative matched-subject design was employed. Twenty participants living with diabetes and peripheral sensory neuropathy were recruited. Ten participants presented with a trans-tibial amputation and 10 had intact feet. Participants were matched for gender, age, foot type and BMI. Peak plantar pressure and pressure time integral data were recorded using the Tekscan HR™ pressure mat system, using the two-step gait protocol. The Shapiro-Wilk test was used to determine normality of data. The Independent Samples t-test and the Mann Whitney U test were carried out to reject the null hypothesis. Although no significant differences (p < 0.05) in mean peak plantar pressures were observed in all the foot masks analysed between the amputee and the control group, a significant difference (p = 0.002) in mean pressure time integrals was recorded with highest pressure time integral (PTI) values under the 2nd-4th metatarsophalangeal joint (MTP joint) for the trans-tibial amputee group. Cumulative exposure of both pressure and time can lead to tissue damage. PTI could be considered as an important contributory factor in determining ulcer formation. Elevated PTI under the 2nd-4th MTP joints sustained in the intact contralateral limb in patients using below knee prosthesis could possibly be due to gait alterations in this population. The preservation of the contralateral limb is of great concern and importance as this might impact patient's mobility and quality of life. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Dimitrova, Svetla
2008-02-01
A group of 86 healthy volunteers were examined on each working day during periods of high solar activity. Data about systolic and diastolic blood pressure, pulse pressure, heart rate and subjective psycho-physiological complaints were gathered. MANOVA was employed to check the significance of the influence of three factors on the physiological parameters. The factors were as follows: (1) geomagnetic activity estimated by daily amplitude of H-component of the local geomagnetic field, Ap- and Dst-index; (2) gender; and (3) the presence of medication. Average values of systolic, diastolic blood pressure, pulse pressure and subjective complaints of the group were found to increase significantly with geomagnetic activity increment.
Alessandri, N; Tufano, F; Petrassi, M; Alessandri, C; Lanzi, L; Fusco, L; Moscariello, F; De Angelis, C; Tomao, E
2010-05-01
The hysto-morfological composition of the ascending aorta wall gives to the vessel its characteristic elasticity/distensibility, which is deteriorated due to both physiological (age) and pathological events (hypertension, diabetes, dyslipidemia). This contributes to reduce the wall elasticity and to occurrence of cardiovascular events. Thirty young healthy subjects (20 males, 10 females, age <30 yr), were subjected to different postural conditions with and without Lower Body Negative Pressure (LBNP) with conventional procedures, to simulate the microgravity conditions in space flight. During this procedure the cardiovascular parameters and the aorta elasticity were assessed with ecocardiography. The observation of results and statistical comparison showed that despite different hemodynamic conditions and with significant variation of blood pressure related to posture, elasticity/distensibility did not change significantly. The elasticity/distensibility of arterial vessels is the result of two interdependent variables such as blood pressure and systolic and diastolic diameters. While blood pressure and heart rate vary physiologically in relation to posture, the compensation of the vessel diameters modifications maintains the aortic compliance invariate. Therefore, in young healthy people, despite the significant postural and the sudden pressure changes (equivalent to parietal stress) aortic compliance does not alter. This behavior might be related to the low rate of cardiovascular events that are present in healthy people aged under 30 yrs.
NASA Astrophysics Data System (ADS)
Li, Chengwu; Xue, Honglai; Hu, Po; Guan, Cheng; Liu, Wenbiao
2018-06-01
Stress has a significant influence on gas diffusion, which is a key factor for methane recovery in coal mines. In this study, a series of experiments were performed to investigate effect of stress on the gas diffusivity during desorption in tectonic coal. Additionally, the desorbed data were modeled using the unipore and bidisperse models. The results show that the bidisperse model better describes the diffusion kinetics than the unipore model in this study. Additionally, the modeling results using the bidisperse approach suggest that the stress impact on the macropore diffusivity is greater than the stress on the micropore diffusivity. Under the same equilibrium pressure, the diffusivity varies with stress according to a four-stage function, which shows an ‘M-shape’. As the equilibrium gas pressure increased from 0.6 to 1.7 MPa, the critical point between stage 2 and stage 3 and between stage 3 and stage 4 transferred to a low stress. This difference is attributed to the gas pressure effects on the physical and mechanical properties of coal. These observations indicate that both the stress and gas pressure can significantly impact gas diffusion and may have significant implications on methane recovery in coal mines.
Serra, X; Grèbol, N; Guàrdia, M D; Guerrero, L; Gou, P; Masoliver, P; Gassiot, M; Sárraga, C; Monfort, J M; Arnau, J
2007-01-01
This paper describes the effect of high pressure (400MPa and 600MPa) applied to frozen hams at early stages of the dry-cured ham process: green hams (GH) and hams at the end of the resting stage (ERS), on the appearance, some texture and flavour parameters and on the instrumental colour characteristics of dry-cured hams. Pressurized hams showed slightly lower visual colour intensity than the control ones. In general, pressurization did not have a significant effect on the flavour characteristics of the final product. The 600-MPa hams from the ERS process showed significantly lower crumbliness and higher fibrousness scores than the control and the 400-MPa hams. However, none of these differences were enough to affect the overall sensory quality of the hams negatively. Regarding instrumental colour characteristics (L(∗)a(∗)b(∗)), an increase in lightness was observed in the biceps femoris muscle from GH hams pressurized at 400MPa and 600MPa but not in the ERS hams.
Boutsioukis, C; Lambrianidis, T; Kastrinakis, E; Bekiaroglou, P
2007-07-01
To monitor ex vivo intra-canal irrigation with three endodontic needles (25, 27 and 30 gauge) and compare them in terms of irrigant flow rate, intra-barrel pressure, duration of irrigation and volume of irrigant delivered. A testing system was constructed to allow measurement of selected variables with pressure and displacement transducers during ex vivo intra-canal irrigation with a syringe and three different needles (groups A, B, C) into a prepared root canal. Ten specialist endodontists performed the irrigation procedure. Each operator performed ten procedures with each needle. Data recorded by the transducers were analysed using Friedman's test, Wilcoxon Signed Rank test, Mann-Whitney U-test and Kendall's T(b) test. The level of significance was set to 95%. Significant differences were detected among the three needles for most variables. Duration of delivery and flow rates significantly decreased as the needle diameter increased, whilst pressure increased up to 400-550 kPa. Gender of the operator had a significant impact on the results. Experience of the operators (years) were negatively correlated to volume of irrigant (all groups), to the duration of delivery (groups A, B) and to the average flow rate (group A). Finer diameter needles require increased effort to deliver the irrigant and result in higher intra-barrel pressure. The syringe and needles used tolerated the pressure developed. Irrigant flow rate should be considered as a factor directly influencing flow beyond the needle. Wide variations of flow rate were observed among operators. Syringe irrigation appears difficult to standardize and control.
2011-01-01
Background Evidence is mounting regarding the clinically significant effect of temperature on blood pressure. Methods In this cross-sectional study the authors obtained minimum and maximum temperatures and their respective previous week variances at the geographic locations of the self-reported residences of 26,018 participants from a national cohort of blacks and whites, aged 45+. Linear regression of data from 20,623 participants was used in final multivariable models to determine if these temperature measures were associated with levels of systolic or diastolic blood pressure, and whether these relations were modified by stroke-risk region, race, education, income, sex hypertensive medication status, or age. Results After adjustment for confounders, same-day maximum temperatures 20°F lower had significant associations with 1.4 mmHg (95% CI: 1.0, 1.9) higher systolic and 0.5 mmHg (95% CI: 0.3, 0.8) higher diastolic blood pressures. Same-day minimum temperatures 20°F lower had a significant association with 0.7 mmHg (95% CI: 0.3, 1.0) higher systolic blood pressures but no significant association with diastolic blood pressure differences. Maximum and minimum previous-week temperature variabilities showed significant but weak relationships with blood pressures. Parameter estimates showed effect modification of negligible magnitude. Conclusions This study found significant associations between outdoor temperature and blood pressure levels, which remained after adjustment for various confounders including season. This relationship showed negligible effect modification. PMID:21247466
Nekooeian, Ali A; Tabrizchi, Reza
1998-01-01
The effects of CGS 21680, a selective A2A adenosine receptor agonist, on cardiac output, blood pressure, mean circulatory filling pressure (Pmcf), arterial and venous resistances, heart rate and left ventricular end-diastolic pressure were assessed in rats with acute heart failure by means of coronary artery occlusion.Animals (n=6 in each group) were divided into five groups: group I, sham-operated vehicle-treated (0.9% saline; 0.018 mL min−1); groups II-V, subject to coronary artery occlusion and treated with vehicle (0.9% saline; 0.018 ml min−1) and CGS 21680 (0.1, 0.3 and 1.0 μg kg−1 min−1), respectively. Haemodynamic measurements were taken one hour after completion of surgery, ninety minutes after coronary artery occlusion (except in group I), and fifteen minutes after infusion of saline or CGS 21680.Baseline haemodynamic measurements before occlusion were found not to differ significantly between the different groups of animals. However, after occlusion, cardiac output, rate of rise in left ventricular pressure (+dP/dt) and blood pressure were significantly reduced when compared to corresponding values in sham-operated animals. In addition, occlusion of the coronary artery resulted in a significant elevation in venous resistance, Pmcf and left ventricular end-diastolic pressure as compared to corresponding values in sham-operated animals.Infusion with CGS 21680 at the highest dose significantly reduced blood pressure, arterial resistance and left ventricular end-diastolic pressure when compared to occluded vehicle-treated animals (group II). Administration of CGS 21680 at the highest dose also significantly increased cardiac output (28%) and heart rate (10%) in comparison to occluded vehicle-treated animals. In addition, the highest dose of CGS 21680 significantly reduced Pmcf (9%) and venous resistance (62%) in comparison to occluded vehicle-treated animals. Administration of CGS 21680 did not significantly affect +dP/dt when compared to occluded vehicle-treated animals.The results from the present investigation indicate that occlusion of the coronary artery in rats results in a state of heart failure characterized by reduced arterial pressure and cardiac output, and increased venous resistance, Pmcf and left ventricular end-diastolic pressure. Administration of CGS 21680 to animals with acute heart failure resulted in increased cardiac output which was due to reduced venous resistance, as well as increased heart rate. PMID:9605574
Nekooeian, A A; Tabrizchi, R
1998-04-01
1. The effects of CGS 21680, a selective A2A adenosine receptor agonist, on cardiac output, blood pressure, mean circulatory filling pressure (Pmcf), arterial and venous resistances, heart rate and left ventricular end-diastolic pressure were assessed in rats with acute heart failure by means of coronary artery occlusion. 2. Animals (n=6 in each group) were divided into five groups: group I, sham-operated vehicle-treated (0.9% saline; 0.018 mL min(-1)); groups II-V, subject to coronary artery occlusion and treated with vehicle (0.9% saline; 0.018 ml min(-1)) and CGS 21680 (0.1, 0.3 and 1.0 microg kg(-1) min(-1)), respectively. Haemodynamic measurements were taken one hour after completion of surgery, ninety minutes after coronary artery occlusion (except in group I), and fifteen minutes after infusion of saline or CGS 21680. 3. Baseline haemodynamic measurements before occlusion were found not to differ significantly between the different groups of animals. However, after occlusion, cardiac output, rate of rise in left ventricular pressure (+ dP/dt) and blood pressure were significantly reduced when compared to corresponding values in sham-operated animals. In addition, occlusion of the coronary artery resulted in a significant elevation in venous resistance, Pmcf and left ventricular end-diastolic pressure as compared to corresponding values in sham-operated animals. 4. Infusion with CGS 21680 at the highest dose significantly reduced blood pressure, arterial resistance and left ventricular end-diastolic pressure when compared to occluded vehicle-treated animals (group II). Administration of CGS 21680 at the highest dose also significantly increased cardiac output (28%) and heart rate (10%) in comparison to occluded vehicle-treated animals. In addition, the highest dose of CGS 21680 significantly reduced Pmcf (9%) and venous resistance (62%) in comparison to occluded vehicle-treated animals. Administration of CGS 21680 did not significantly affect +dP/dt when compared to occluded vehicle-treated animals. 5. The results from the present investigation indicate that occlusion of the coronary artery in rats results in a state of heart failure characterized by reduced arterial pressure and cardiac output, and increased venous resistance, Pmcf and left ventricular end-diastolic pressure. Administration of CGS 21680 to animals with acute heart failure resulted in increased cardiac output which was due to reduced venous resistance, as well as increased heart rate.
Swift, Damon L.; Earnest, Conrad P.; Katzmarzyk, Peter T.; Rankinen, Tuomo; Blair, Steven N.; Church, Timothy S.
2011-01-01
Objective Abnormally elevated exercise blood pressure is associated with increased risk of cardiovascular disease. Aerobic exercise training has been shown to reduce exercise blood pressure. However, it is unknown if these improvements occur in a dose dependent manner. The purpose of the present study is to determine the effect of different doses of aerobic exercise training on exercise blood pressure in obese postmenopausal women. Methods Participants (n=404) were randomized to one of 4 groups: 4, 8, or 12 kilocalories per kilogram of energy expenditure per week (kcal/kg/week) or the non-exercise control group for 6 months. Exercise blood pressure was obtained during the 50 watts stage of a cycle ergometer maximal exercise test. Results There was a significant reduction in systolic blood pressure at 50 watts in the 4 kcal/kg/week (−10.9 mmHg, p< 0.001), 8 kcal/kg/week (−9.9 mmHg, p= 0.022), and 12 kcal/kg/week (−13.7 mmHg, p<0.001) compared to control (−4.2 mmHg). Only the highest exercise training dose significantly reduced diastolic blood pressure (−4.3 mmHg, p= 0.033) compared to control. Additionally, resting blood pressure was not altered following exercise training (p>0.05) compared to control, and was not associated with changes in exercise systolic (r=0.09, p=0.09) or diastolic (r=0.10, p=0.08) blood pressure. Conclusions Aerobic exercise training reduces exercise blood pressure and may be more modifiable than changes in resting blood pressure. A high dose of aerobic exercise is recommended to successfully reduce both exercise systolic and diastolic blood pressure, and therefore may attenuate the CVD risk associated with abnormally elevated exercise blood pressure. PMID:22547251
2012-01-01
Background Systemic hypertension is a prominent feature in humans with metabolic syndrome (MS) and this is partly caused by an enhanced endothelin-1 (ET-1) mediated vasoconstriction. There are indications that systemic hypertension might be a feature in equine metabolic syndrome (EMS) but if ET-1 is involved in the development of hypertension in horses is not known. Increased levels of cortisol have also been found in humans with MS but there are no reports of this in horses. Before blood pressure, plasma ET-1 and serum cortisol can be evaluated in horses with EMS, it is necessary to investigate the interday variation of these parameters on clinically healthy horses. The aims of the present study were therefore to evaluate the interday variation and influence of transportation on systemic blood pressure, plasma ET-1 and serum cortisol in healthy Standardbred and Icelandic horses, and to detect potential breed differences. Methods Nine horses of each breed were included in the study. Blood pressure was measured and blood samples were collected between 6 and 9 am on two separate days. Eight of the horses (four of each breed) were transported to a new stable were they stayed overnight. The next morning, the sampling procedure was repeated. Results The interday variation was higher for plasma ET-1 (37%) than for indirect pressure measurements (8-21%) and serum cortisol (18%). There were no differences in systemic blood pressure between the two breeds. The Icelandic horses had significantly lower serum cortisol and significantly higher plasma ET-1 concentrations compared to the Standardbred horses. Plasma ET-1 was significantly elevated after transportation, but systemic blood pressure and serum cortisol did not differ from the values obtained in the home environment. Conclusions Indirect blood pressure, plasma ET-1 and serum cortisol are of interest as markers for cardiovascular dysfunction in horses with EMS. The elevated plasma ET-1 concentrations recorded after transportation was likely caused by a stress response. This needs to be considered when evaluating plasma ET-1 in horses after transportation. The differences detected in plasma ET-1 and serum cortisol between the two breeds might be related to differences in genetic setup, training status as well as management conditions. PMID:22682151
Macintyre, Lisa; Stewart, Hazel; Rae, Michelle
2016-12-01
Deep vein thrombosis is a major global health issue, responsible for thousands of deaths each year. While thrombi can form under a variety of circumstances, lack of mobility significantly increases risk and therefore non-ambulant patients are frequently fitted with anti-embolism stockings on admission to hospital, to aid blood flow, prevent pooling and thus clotting. Anti-embolism stockings are the most widely used non-invasive medical device on the market and are believed to reduce the risk of deep vein thrombosis by 40%. Despite their widespread use in hospitals world-wide, there is remarkably little research addressing their use or reconditioning and a wide variety of different reconditioning protocols are used in hospitals. The objective of this study was to establish the impact of different wear and reconditioning protocols on the pressure delivering ability of anti-embolism stockings. A laboratory investigation was undertaken to evaluate the pressure delivering ability of 2 major global brands of anti-embolism stockings over 5-8days of simulated wear (extension on static cylinders) and 4 different reconditioning protocols. 1 set of samples was continuously 'worn' for 8days without reconditioning, 1 set of samples was 'worn' for 5days with a day of relaxation between each day of 'wear', 1 set was 'hand washed' and 1 set was machine washed and then allowed to relax between each day of 'wear'. The pressure was measured at the beginning and end of each period of 'wear'. This study was undertaken in a conditioned textile testing laboratory that complies with BS EN ISO 139:2005+A1:2011. The pressure exerted by anti-embolism stockings reduced by between 15 and 24% after 24h of wear, it reduced by between 21 and 32% when worn continuously for 8days. Allowing stockings to rest for a day between days of wear allowed them to recover slightly but this recovery was only temporary. Washing stockings regenerated their pressure delivering potential significantly and machine washing allowed some to recover to exert more pressure than they had when new. Different brands of anti-embolism stockings exert different pressures on the same size of leg, when correctly fitted. The pressure exerted by anti-embolism stockings decreases with use but the correct pressure gradient is maintained if correctly fitted. Washing stockings after 24h of wear is effective in restoring their pressure delivering abilities and in some cases can surpass their 'as new' pressure delivering ability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hydrostatic pressure influences HIF-2 alpha expression in chondrocytes.
Inoue, Hiroaki; Arai, Yuji; Kishida, Tsunao; Terauchi, Ryu; Honjo, Kuniaki; Nakagawa, Shuji; Tsuchida, Shinji; Matsuki, Tomohiro; Ueshima, Keiichirou; Fujiwara, Hiroyoshi; Mazda, Osam; Kubo, Toshikazu
2015-01-05
Hypoxia-inducible factor (HIF)-2α is considered to play a major role in the progression of osteoarthritis. Recently, it was reported that pressure amplitude influences HIF-2α expression in murine endothelial cells. We examined whether hydrostatic pressure is involved in expression of HIF-2α in articular chondrocytes. Chondrocytes were cultured and stimulated by inflammation or hydrostatic pressure of 0, 5, 10, or 50 MPa. After stimulation, heat shock protein (HSP) 70, HIF-2α, nuclear factor kappa B (NF-κB), matrix metalloproteinase (MMP)-13, MMP-3, and vascular endothelial growth factor (VEGF) gene expression were evaluated. The levels of all gene expression were increased by inflammatory stress. When chondrocytes were exposed to a hydrostatic pressure of 5 MPa, HIF-2α, MMP-13, and MMP-3 gene expression increased significantly although those of HSP70 and NF-κB were not significantly different from the control group. In contrast, HIF-2α gene expression did not increase under a hydrostatic pressure of 50 MPa although HSP70 and NF-κB expression increased significantly compared to control. We considered that hydrostatic pressure of 5 MPa could regulate HIF-2α independent of NF-κB, because the level of HIF-2α gene expression increased significantly without upregulation of NF-κB expression at 5 MPa. Hydrostatic pressure may influence cartilage degeneration, inducing MMP-13 and MMP-3 expression through HIF-2α.
Kim, Sung-Jin; Yokokawa, Ryuji; Takayama, Shuichi
2012-01-01
This paper reveals a critical limitation in the electro-hydraulic analogy between a microfluidic membrane-valve (μMV) and an electronic transistor. Unlike typical transistors that have similar on and off threshold voltages, in hydraulic μMVs, the threshold pressures for opening and closing are significantly different and can change, even for the same μMVs depending on overall circuit design and operation conditions. We explain, in particular, how the negative values of the closing threshold pressures significantly constrain operation of even simple hydraulic μMV circuits such as autonomously switching two-valve microfluidic oscillators. These understandings have significant implications in designing self-regulated microfluidic devices. PMID:23284181
Trend of blood pressure in hypertensive and normotensive volunteers during Ramadan fasting.
Norouzy, Abdolreza; Hasanzade Daloee, Mahdi; Khoshnasab, Amir Hosein; Khoshnasab, Adeleh; Farrokhi, Javad; Nematy, Mohsen; Safarian, Mohammad; Nezafati, Pouya; Alinezhad-Namaghi, Maryam
2017-10-01
It is believed that Ramadan fasting regulates blood pressure, heart rate, and other cardiovascular risk factors. This study aimed to investigate the effect of Ramadan fasting on ambulatory blood pressure in hypertensive patients. This prospective, observational study was carried out in two groups: one group included hypertensive patients treated with two antihypertensive agents (n=6) and the other group included healthy individuals (n=12). We performed 24-h blood pressure monitoring at four time points: before Ramadan, during the first and last 10 days of Ramadan, and 1 month after Ramadan. All hypertensive patients followed their twice-daily treatment regimen. Mean 24-h blood pressure (as well as mean blood pressure values during awake and sleep periods), body weight, and waist circumference were measured in the two groups. There were no significant differences in the trends of systolic and diastolic blood pressure between the hypertensive and nonhypertensive groups during Ramadan and 1 month after it. However, the trends of variations in heart rate and body weight were not significantly different in the two groups (P<0.001 and P=0.016, respectively). There was a significant increase in heart rate during the first period of Ramadan in hypertensive patients (P=0.018), whereas it improved during the post-Ramadan period in comparison with the second period of measurements (P=0.019). Furthermore, there was a significant decline in heart rate during the post-Ramadan measurement compared with that before Ramadan in the nonhypertensive group (P=0.008).In addition, there was a significant weight gain in the third period in comparison with the previous period in the hypertensive group (73.1±11 vs. 72.2±12; P=0.011). This finding indicates that Ramadan fasting might be nonthreatening for patients with essential hypertension if the treatment regimen is complied with.
Pressure-relieving properties of a intra-operative warming device.
Baker, E A; Leaper, D J
2003-04-01
The primary objective of this study was to determine differences in interface pressure between four mattress combinations: a standard operating table mattress, a pressure-relieving gel pad and an under-patient warming device set at 38 degrees C (Pegasus Inditherm System) and at ambient temperature. The secondary objective was to determine whether the warming device remains stable in extreme surgical positions. Interface pressures obtained with all four combinations were measured in 10 healthy volunteers using force sensing array technology. The warming device demonstrated better or equivalent pressure relief when compared with the standard gel pad. There was no significant difference in subject position 'shift' between the mattress, the gel pad and the warming device for either the Trendelenberg or reverse Trendelenberg positions. Both pressure-relieving mattresses and warming reduce intra-operative pressure damage. A mattress with both properties may further reduce pressure damage postoperatively. The warming device used in this study appears stable--subject 'slippage' was minimal in extreme positions. Research needs to be conducted among real anaesthetised patients to support these conclusions.
A physical interpretation of softening of pressure-sensitive and anisotropic materials
NASA Astrophysics Data System (ADS)
Hu, W.; Wang, Z. R.
2010-07-01
Several new dynamic models are proposed to explain the mechanical behaviour of softening of pressure-sensitive and anisotropic materials at a macroscopic level. If a pressure-sensitive material is loaded by a force and a variable pressure or an anisotropic material is subjected to a load with a changeable loading direction relative to the material frame, their stress-strain relationships become more complicated. Mechanical behaviours of these stress-strain relationships have to cover the feature concerning the change of pressure or loading direction, i.e. mechanical properties of pressure-sensitive material corresponding to different pressure state or anisotropic material relating to different loading direction will play an important role in deciding their stress-strain relationships. Such shift of material properties due to the variable pressure or loading history may significantly expand the traditional concept of the stability of material deformation, and the second order of plastic work being negative may be a response of stable plastic deformation, which is commonly called softening.
Arterial and intraocular pressure changes after a single-session hot-water immersion.
Findikoglu, Gulin; Cetin, Ebru Nevin; Sarsan, Ayse; Senol, Hande; Yildirim, Cem; Ardic, Fusun
2015-01-01
The aim of this study is to investigate the effect of head-out hot-water immersion on the intraocular pressure (IOP) of healthy subjects and investigate whether this intervention alters cardiovascular and microcirculatory responses. METHODs: 16 male and 18 female healthy young adults were immersed in 39 degrees C water up to shoulder level for 20 minutes. Blood pressure (BP), heart rate (HR) and IOP were measured pre-immersion, post-immersion and five minutes after immersion on the same day. Tono-Pen was used to measure IOP. Mean arterial blood pressure (MAP), systolic pressure rate product (S-PRP), diastolic pressure rate product (D-PRP), pulse pressure (PP), mean ocular perfusion pressure (mean-OPP), systolic ocular perfusion pressure (S-OPP) and diastolic ocular perfusion pressure (D-OPP) were calculated. Systolic BP (SBP), diastolic BP (DBP), MAP, IOP, S-OPP, D-OPP and mean-OPP decreased; HR increased five minutes after immersion in the pool and post-immersion out of the pool significantly, compared to pre-immersion data (p < 0.05). HR, S-PRP and D-PRP measured five minutes after immersion were significantly higher from post-immersion (p < 0.05). PP and S-OPP were significantly different five minutes after immersion compared to pre-immersion. There was no statistically significant correlation between IOP and SBP, DBP, MAP, S-PRP, D-PRP, PP, S-OPP, D-OPP, or mean-OPP (p > 0.05). Physiological hemodynamic response to single head-out hot-water immersion caused a statistically significant decrease in IOP. Preliminary results could help to clarify vascular reactions and IOP changes during hot-water immersion that might be potentially therapeutic in glaucoma patients.
Gharaibeh, Monther A; Chen, Darren B; MacDessi, Samuel J
2018-05-01
Sensor-guided assessment for soft tissue balance in total knee arthroplasty (TKA) has been reported to improve patient satisfaction and self-reported outcome scores. As more surgeons adopt this technology in TKA, we performed this study to identify if there is a learning curve with its use. Analysis of a total of 90 consecutive cases was performed in this study. Initial and final intercompartmental pressure differences were recorded before and after knee ligament balancing. The first 45 patients (group 1) were compared to the last 45 patients (group 2) in terms of operative time and the final state of knee balance. A balanced knee was defined as pressure difference between medial and lateral compartments of ≤15 pounds. Group 1 had 10 unbalanced knees in the final pressure difference assessment, while all cases in group 2 were balanced (P < 0.001). There was no statistically significant difference in mean operative time between the two groups. A scatter plot of intercompartmental pressure difference identified that after 30 cases, the capacity to achieve knee ligament balance improved. This study suggests that there is a learning curve with the use of sensor-guided assessment in TKA in achieving knee balance; however, the differences noted between initial and final groups were small and may not be of clinical significance. © 2018 Royal Australasian College of Surgeons.
Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.
Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D
2017-06-27
Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Cardiovascular regulation during head-up tilt in healthy 20-30-year-old and 70-75-year-old men.
Gabbett, T J; Weston, S B; Barrett, R S; Gass, G C
2001-02-01
This study compared the heart rate, finger arterial pressure (AP) and electromyographic (EMG) activity of selected anti-gravity muscles during the initial and prolonged phases of orthostatic stress in healthy young and older men. Beat-by-beat recordings of heart rate, finger systolic pressure, diastolic pressure and mean AP were made during supine rest and 5 min of 90 degrees head-up tilt (HUT) in 18 young (23+/-1 years) and 15 older (73+/-1 years) men. The EMG activity of the soleus, tibialis anterior and vastus medialis muscles was recorded. During the first 30 s following 90 degrees HUT (immediate response), the young men exhibited significant (P<0.05) decreases in finger systolic pressure, diastolic pressure and mean AP, followed by a sustained increase in finger AP during the 5 min following 90 degrees HUT (prolonged response). The immediate and prolonged finger AP and diastolic pressure responses were not significantly different (P>0.05) from the values at supine rest for the older men. The mean root mean square EMG activity of the soleus, tibialis anterior and vastus medialis muscles during 90 degrees HUT was not significantly different (P>0.05) from that at supine rest for either group. These results demonstrate that, when compared with healthy older men, young men show larger reductions in finger AP during the initial phase of orthostatic stress. However, during the prolonged phase of orthostatic stress, older men maintain resting finger AP, whereas young men demonstrate a reflex overshoot in finger AP. Finally, differences in lower-limb anti-gravity muscle activation do not account for the contrasting finger AP responses of healthy young and older men.
Bekiroğlu, Tansel; Ovayolu, Nimet; Ergün, Yusuf; Ekerbiçer, Hasan Çetin
2013-06-01
Existing studies suggest that music therapy can have favorable effects on hypertension and anxiety. We therefore set out to investigate the effect of Turkish classical music. To investigate whether Turkish classical music has positive effects on blood pressures and anxiety levels in elderly patients. This was a randomized controlled trial performed on 60 hypertensive patients living in a local elderly home in Adana, Turkey. Following the completion of a socio-demographic form for each patient, Hamilton anxiety scale was applied. Thereafter, the subjects were randomly divided into two equal-size groups and were allowed to either listen to Turkish classical music (music therapy group) or have a resting period (control group) for 25 min. The primary and secondary outcome measures were blood pressure and Hamilton anxiety scale scores, respectively. The mean reduction in systolic blood pressure was 13.00 mmHg in the music therapy group and 6.50 mmHg in the control group. The baseline adjusted between treatment group difference was not statistically significant (95% CI 6.80-9.36). The median reductions in diastolic blood pressures were 10 mmHg both in the music therapy and control groups. The between treatment group difference was not statistically significant (Mann-Whitney U test, P = 0.839). The mean reduction in HAMA-A was 1.63 in the music therapy group and 0.77 in the control group. The baseline adjusted between treatment group difference was not statistically significant (95% CI 0.82-1.92). The study demonstrated that both Turkish classical music and resting alone have positive effects on blood pressure in patients with hypertension. Copyright © 2013 Elsevier Ltd. All rights reserved.
Blood pressure in early autosomal dominant polycystic kidney disease.
Schrier, Robert W; Abebe, Kaleab Z; Perrone, Ronald D; Torres, Vicente E; Braun, William E; Steinman, Theodore I; Winklhofer, Franz T; Brosnahan, Godela; Czarnecki, Peter G; Hogan, Marie C; Miskulin, Dana C; Rahbari-Oskoui, Frederic F; Grantham, Jared J; Harris, Peter C; Flessner, Michael F; Bae, Kyongtae T; Moore, Charity G; Chapman, Arlene B
2014-12-11
Hypertension is common in autosomal dominant polycystic kidney disease (ADPKD) and is associated with increased total kidney volume, activation of the renin-angiotensin-aldosterone system, and progression of kidney disease. In this double-blind, placebo-controlled trial, we randomly assigned 558 hypertensive participants with ADPKD (15 to 49 years of age, with an estimated glomerular filtration rate [GFR] >60 ml per minute per 1.73 m(2) of body-surface area) to either a standard blood-pressure target (120/70 to 130/80 mm Hg) or a low blood-pressure target (95/60 to 110/75 mm Hg) and to either an angiotensin-converting-enzyme inhibitor (lisinopril) plus an angiotensin-receptor blocker (telmisartan) or lisinopril plus placebo. The primary outcome was the annual percentage change in the total kidney volume. The annual percentage increase in total kidney volume was significantly lower in the low-blood-pressure group than in the standard-blood-pressure group (5.6% vs. 6.6%, P=0.006), without significant differences between the lisinopril-telmisartan group and the lisinopril-placebo group. The rate of change in estimated GFR was similar in the two medication groups, with a negative slope difference in the short term in the low-blood-pressure group as compared with the standard-blood-pressure group (P<0.001) and a marginally positive slope difference in the long term (P=0.05). The left-ventricular-mass index decreased more in the low-blood-pressure group than in the standard-blood-pressure group (-1.17 vs. -0.57 g per square meter per year, P<0.001); urinary albumin excretion was reduced by 3.77% with the low-pressure target and increased by 2.43% with the standard target (P<0.001). Dizziness and light-headedness were more common in the low-blood-pressure group than in the standard-blood-pressure group (80.7% vs. 69.4%, P=0.002). In early ADPKD, the combination of lisinopril and telmisartan did not significantly alter the rate of increase in total kidney volume. As compared with standard blood-pressure control, rigorous blood-pressure control was associated with a slower increase in total kidney volume, no overall change in the estimated GFR, a greater decline in the left-ventricular-mass index, and greater reduction in urinary albumin excretion. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; HALT-PKD [Study A] ClinicalTrials.gov number, NCT00283686.).
Gender-related differences in adolescent hypertension and in target organ effects.
Juhász, Mária; Katona, Eva; Settakis, Georgios; Paragh, György; Molnár, Csilla; Fülesdi, Béla; Páll, Dénes
2010-04-01
To assess whether a gender difference exists in adolescent hypertension and its target organ damage and to compare potential confounding factors and target organ damage in hypertensive and normotensive adolescent girls. From the Debrecen Hypertension Study, the anthropometric, blood pressure, and laboratory data as well as intima-media thickness (IMT) and left ventricular mass index (LVMI) of 58 hypertensive boys, 56 hypertensive girls, and 30 normotensive girls were analyzed. Both systolic and mean blood pressure values were higher in adolescent hypertensive boys than in girls. This difference was also present when comparing 24-hour average blood pressure values. Plasma concentrations of nitric oxide (NO) and endothelin-1 were not different in the two gender groups. IMT of the carotid arteries were similar in hypertensive boys and girls, but a significantly higher LVMI was detected in boys. A significant difference was detected in anthropometric data (height, weight, and body mass index [BMI]), plasma concentration of NO (lower levels in hypertensives), and IMT in hypertensive and normotensive girls (higher IMT in hypertensive girls). There is a difference between the severity of hypertension between hypertensive adolescent girls and boys. Hypertensive girls differ from normotensive girls not only in blood pressure values but also in risk factors and subclinical target organ effects. Further studies are needed to explain the gender differences in adolescent hypertension. The potential role of sex hormones in hypertensive teenagers also needs to be clarified in future works.
Yuan, Qiang; Wu, Xing; Yu, Jian; Sun, Yirui; Li, Zhiqi; Du, Zhuoying; Mao, Ying; Zhou, Liangfu; Hu, Jin
2015-07-01
To evaluate the efficacy of traumatic brain injury management guided by intracranial pressure monitoring and to explore the specific subgroups for which intracranial pressure monitoring might be significantly associated with improved outcomes based on a classification of the various traumatic brain injury pathophysiologies using the clinical features and CT scans. Retrospective observational multicenter study. Twenty-two hospitals (16 level I trauma centers and six level II trauma centers) in nine provinces in China. Moderate or severe traumatic brain injury patients who were more than 14 years old. Intracranial pressure monitoring. All data were collected by physicians from medical records. The 6-month mortality and favorable outcome were assessed with the Glasgow Outcome Scale Extended score. An intracranial pressure monitor was inserted into 838 patients (58.1%). The mean duration of intracranial pressure monitoring was 4.44 ± 3.65 days. The significant predictors of intracranial pressure monitoring included the mechanism of injury, a Glasgow Coma Scale score of 9-12 at admission that dropped to a score of 3-8 within 24 hours after injury, a Marshall CT classification of III-IV, the presence of a major extracranial injury, subdural hematoma, intraparenchymal lesions, trauma center level, and intracranial pressure monitoring utilization of hospital. The intracranial pressure monitoring and no intracranial pressure monitoring groups did not significantly differ in terms of complications. For the total sample, the placement of intracranial pressure monitoring was not associated with either 6-month mortality (16.9% vs 20.5%; p = 0.086) or 6-month unfavorable outcome (49.4% vs 45.8%; p = 0.175). For patients with a Glasgow Coma Scale score of 3-8 at admission, intracranial pressure monitoring was also not significantly associated with 6-month mortality (20.9% vs 26.0%; p = 0.053) or an unfavorable outcome (56.9% vs 55.5%; p = 0.646). Multivariate logistic regression analyses showed that intracranial pressure monitoring resulted in a significantly lower 6-month mortality for patients who had a Glasgow Coma Scale score of 3-5 at admission (adjusted odds ratio, 0.57; 95% CI, 0.36-0.90; adjusted p = 0.016), those who had a Glasgow Coma Scale score of 9-12 at admission that dropped to 3-8 within 24 hours after injury (adjusted odds ratio, 0.28; 95% CI, 0.08-0.96; adjusted p = 0.043), and those who had a probability of death at 6 months greater than 0.6 (adjusted odds ratio, 0.55; 95% CI, 0.32-0.94; adjusted p = 0.029). There were multiple differences between the intracranial pressure monitoring and no intracranial pressure monitoring groups regarding patient characteristics, injury severity, characteristics of CT scan, and hospital type. Intracranial pressure monitoring in conjunction with intracranial pressure-targeted therapies is significantly associated with lower mortality in some special traumatic brain injury subgroups. The prospective randomized controlled trials specifically investigating these subgroups will be required to further characterize the effects of intracranial pressure monitoring on behavioral outcomes in patients with traumatic brain injury.
Whitehead, Paul N.; Schilling, Brian K.; Farney, Tyler M.; Bloomer, Richard J.
2012-01-01
Background: 1,3-dimethylamylamine is a commonly used ingredient within dietary supplements. Our prior work with this agent indicates a transient increase in blood pressure (systolic in particular) following oral ingestion of a single dosage, but no significant increase in resting blood pressure following chronic ingestion. Moreover, intervention studies involving both two and eight weeks of treatment with finished products containing 1,3-dimethylamylamine indicate minimal or no change in bloodborne markers of health. The present study sought to extend these findings by using a 10-week intervention trial to determine the change in selected markers of health in a sample of men. Methods: 25 healthy men were randomly assigned to either a placebo (n = 13) or to a supplement containing 1,3-dimethylamylamine (n = 12) for a period of 10 weeks. Before and after the intervention, resting blood pressure and heart rate were measured, and blood samples were collected for determination of complete blood count, metabolic panel, and lipid panel. Results: No significant differences were noted between conditions for blood pressure (P > 0.05), although systolic blood pressure increased approximately 6 mmHg with the supplement (diastolic blood pressure decreased approximately 4 mmHg). A main effect for time was noted for heart rate (P = 0.016), with values decreasing from pre to post intervention. There were significant main effects for time for creatinine (increased from pre to post intervention; P = 0.043) and alkaline phosphatase (decreased from pre to post intervention; P = 0.009), with no condition differences noted (P > 0.05). There was a significant interaction noted for low density lipoprotein cholesterol (LDL-C) (P = 0.043), with values decreasing in the supplement group from pre to post intervention approximately 7 mg · dL−1 (P = 0.034). No other effects of significance were noted for bloodborne variables. Conclusion: These data indicate that a dietary supplement containing 1,3-dimethylamylamine does not result in a statistically significant increase in resting heart rate or blood pressure (although systolic blood pressure is increased ∼6 mmHg with supplement use). The supplement does not negatively impact bloodborne markers of health. Further study is needed involving a longer intervention period, a larger sample size, and additional measures of health and safety. PMID:23882146
Jiang, Yan; Ye, Zeng pan-pan; You, Chao; Hu, Xin; Liu, Yi; Li, Hao; Lin, Sen; Li, Ji-Pin
2015-10-01
To determine an optimal head elevation degree to decrease intracranial pressure in postcraniotomy patients by meta-analysis. A change in head position can lead to a change in intracranial pressure; however, there are conflicting data regarding the optimal degree of elevation that decreases intracranial pressure in postcraniotomy patients. Quantitative systematic review with meta-analysis following Cochrane methods. The data were collected during 2014; three databases (PubMed, Embase and China National Knowledge Internet) were searched for published and unpublished studies in English. The bibliographies of the articles were also reviewed. The inclusion criteria referred to different elevation degrees and effects on intracranial pressure in postcraniotomy patients. According to pre-determined inclusion criteria and exclusion criteria, two reviewers extracted the eligible studies using a standard data form. These included a total of 237 participants who were included in the meta-analysis. (1) Compared with 0 degree: 10, 15, 30 and 45 degrees of head elevation resulted in lower intracranial pressure. (2) Intracranial pressure at 30 degrees was not significantly different in comparison to 45 degrees and was lower than that at 10 and 15 degrees. Patients with increased intracranial pressure significantly benefitted from a head elevation of 10, 15, 30 and 45 degrees compared with 0 degrees. A head elevation of 30 or 45 degrees is optimal for decreasing intracranial pressure. Research about the relationship of position changes and the outcomes of patient primary diseases is absent. © 2015 John Wiley & Sons Ltd.
Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection.
Qing, K-X; Chan, Y-C; Ting, A C W; Cheng, S W K
2016-05-01
Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective. Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models. False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p < .001); MPI and AUCI (99.5% vs. 128.2%; 99.5% vs. 128%; p < .001). The SI, MPI, and AUCI were significantly higher in Model B compared with Model C. The differences between the four indices were not significant between Model A and B. The false lumen area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg). The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intra-thrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Wang, Tzung-Dau; Tan, Ru-San; Lee, Hae-Young; Ihm, Sang-Hyun; Rhee, Moo-Yong; Tomlinson, Brian; Pal, Parasar; Yang, Fan; Hirschhorn, Elizabeth; Prescott, Margaret F; Hinder, Markus; Langenickel, Thomas H
2017-01-01
Salt-sensitive hypertension (SSH) is characterized by impaired sodium excretion and subnormal vasodilatory response to salt loading. Sacubitril/valsartan (LCZ696) was hypothesized to increase natriuresis and diuresis and result in superior blood pressure control compared with valsartan in Asian patients with SSH. In this randomized, double-blind, crossover study, 72 patients with SSH received sacubitril/valsartan 400 mg and valsartan 320 mg once daily for 4 weeks each. SSH was diagnosed if the mean arterial pressure increased by ≥10% when patients switched from low (50 mmol/d) to high (320 mmol/d) sodium diet. The primary outcome was cumulative 6- and 24-hour sodium excretion after first dose administration. Compared with valsartan, sacubitril/valsartan was associated with a significant increase in natriuresis (adjusted treatment difference: 24.5 mmol/6 hours, 50.3 mmol/24 hours, both P<0.001) and diuresis (adjusted treatment difference: 291.2 mL/6 hours, P<0.001; 356.4 mL/24 hours, P=0.002) on day 1, but not on day 28, and greater reductions in office and ambulatory blood pressure on day 28. Despite morning dosing of both drugs, ambulatory blood pressure reductions were more pronounced at nighttime than at daytime or the 24-hour average. Compared with valsartan, sacubitril/valsartan significantly reduced N-terminal pro B-type natriuretic peptide levels on day 28 (adjusted treatment difference: -20%; P=0.001). Sacubitril/valsartan and valsartan were safe and well tolerated with no significant changes in body weight or serum sodium and potassium levels with either treatments. In conclusion, sacubitril/valsartan compared with valsartan was associated with short-term increases in natriuresis and diuresis, superior office and ambulatory blood pressure control, and significantly reduced N-terminal pro B-type natriuretic peptide levels in Asian patients with SSH. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01681576. © 2016 American Heart Association, Inc.
Effect of resistance exercise training combined with relatively low vascular occlusion.
Sumide, Takahiro; Sakuraba, Keishoku; Sawaki, Keisuke; Ohmura, Hirotoshi; Tamura, Yoshifumi
2009-01-01
Previous studies have demonstrated that a low-intensity resistance exercise, combined with vascular occlusion, results in a marked increase in muscular size and strength. We investigated the optimal pressure for reduction of muscle blood flow with resistance exercise to increase the muscular strength and endurance. Twenty-one subjects were randomly divided into four groups by the different application of vascular occlusion pressure at the proximal of thigh: without any pressure (0-pressure group), with a pressure of 50mmHg (50-pressure group), with a pressure of 150mmHg (150-pressure group), and with a pressure of 250mmHg (250-pressure group). The isokinetic muscle strength at angular velocities of 60 and 180 degrees /s, total muscle work, and the cross-sectional knee extensor muscle area were assessed before and after exercise. Exercise was performed three times a week over an 8-week period at an intensity of approximately 20% of one-repetition maximum for straight leg raising and hip joint adduction and maximum force for abduction training. A significant increase in strength at 180 degrees /s was noted after exercise in all subjects who exercised under vascular occlusion. Total muscle work increased significantly in the 50- and 150-pressure groups (P<0.05, P<0.01, respectively). There was no significant increase in cross-sectional knee extensor muscle area in any groups. In conclusion, resistance exercise with relatively low vascular occlusion pressure is potentially useful to increase muscle strength and endurance without discomfort.
Bramley, Helen; Turner, Neil C; Turner, David W; Tyerman, Stephen D
2007-07-01
Hydrostatic pressure relaxations with the root pressure probe are commonly used for measuring the hydraulic conductivity (Lp(r)) of roots. We compared the Lp(r) of roots from species with different root hydraulic properties (Lupinus angustifolius L. 'Merrit', Lupinus luteus L. 'Wodjil', Triticum aestivum L. 'Kulin' and Zea mays L. 'Pacific DK 477') using pressure relaxations, a pressure clamp and osmotic gradients to induce water flow across the root. Only the pressure clamp measures water flow under steady-state conditions. Lp(r) determined by pressure relaxations was two- to threefold greater than Lp(r) from pressure clamps and was independent of the direction of water flow. Lp(r) (pressure clamp) was two- to fourfold higher than for Lp(r) (osmotic) for all species except Triticum aestivum where Lp(r) (pressure clamp) and Lp(r) (osmotic) were not significantly different. A novel technique was developed to measure the propagation of pressure through roots to investigate the cause of the differences in Lp(r). Root segments were connected between two pressure probes so that when root pressure (P(r)) was manipulated by one probe, the other probe recorded changes in P(r). Pressure relaxations did not induce the expected kinetics in pressure in the probe at the other end of the root when axial hydraulic conductance, and probe and root capacitances were accounted for. An electric circuit model of the root was constructed that included an additional capacitance in the root loaded by a series of resistances. This accounted for the double exponential kinetics for intact roots in pressure relaxation experiments as well as the reduced response observed with the double probe experiments. Although there were potential errors with all the techniques, we considered that the measurement of Lp(r) using the pressure clamp was the most unambiguous for small pressure changes, and provided that sufficient time was allowed for pressure propagation through the root. The differences in Lp(r) from different methods of measurement have implications for the models describing water transport through roots and the potential role of aquaporins.
NASA Astrophysics Data System (ADS)
Xue, Rong; Ruan, Yixiao; Liu, Xiufang; Cao, Feng; Hou, Yu
2017-09-01
Spray cooling with cryogen could achieve lower temperature level than refrigerant spray. The internal flow conditions within spray nozzles have crucial impacts on the mass flow rate, particle size, spray angle and spray penetration, thereby influencing the cooling performance. In this paper, CFD simulations based on mixture model are performed to study the cavitating flow of liquid nitrogen in spray nozzles. The cavitation model is verified using the experimental results of liquid nitrogen flow over hydrofoil. The numerical models of spray nozzle are validated against the experimental data of the mass flow rate of liquid nitrogen flow through different types of nozzles including the pressure swirl nozzle and the simple convergent nozzle. The numerical studies are performed under a wide range of pressure difference and inflow temperature, and the vapor volume fraction distribution, outlet vapor quality, mass flow rate and discharge coefficient are obtained. The results show that the outlet diameter, the pressure difference, and the inflow temperature significantly influence the mass flow rate of spray nozzles. The increase of the inflow temperature leads to higher saturation pressure, higher cavitation intensity, and more vapor at nozzle outlet, which can significantly reduce mass flow rate. While the discharge coefficient is mainly determined by the inflow temperature and has little dependence on the pressure difference and outlet diameter. Based on the numerical results, correlations of discharge coefficient are proposed for pressure swirl nozzle and simple convergent nozzles, respectively, and the deviation is less than 20% for 93% of data.
Benninger, Emanuel; Labler, Ludwig; Seifert, Burkhardt; Trentz, Otmar; Menger, Michael D; Meier, Christoph
2008-01-01
To compare volume reserve capacity (VRC) and development of intra-abdominal hypertension after different in vitro temporary abdominal closure (TAC) techniques. A model of the abdomen was designed. The abdominal wall was simulated with polychloroprene, a synthetic rubber compound. A lentil-shaped defect of 150 cm(2) was cut into the anterior aspect of the abdominal wall. TAC of this defect was performed by a zipper system (ZS), a bag silo closure (BSC), or a vacuum assisted closure (VAC) with subatmospheric pressures ranging from 0- to 200 mmHg. The model with intact abdominal wall served as reference. The model was filled with water to baseline level. The intra-abdominal pressure was increased in 2 mmHg steps from baseline level (6 mmHg) to 40 mmHg by adding volume to the system according to a standardized protocol. VRC with corresponding intra-abdominal pressure were analyzed and compared for the different TAC techniques. VRC was the highest after BSC at all pressure levels studied (P < 0.05). VAC and ZS resulted in significantly lower VRC compared with BSC and reference (P < 0.05). The magnitude of negative pressure on the VAC did not significantly influence the VRC. In the present in vitro model, BSC demonstrated the highest VRC of all evaluated TAC techniques. Different levels of subatmospheric pressures applied to the VAC did not affect VRC. The results for ZS and VAC indicate that these TAC techniques may increase the risk for recurrent intra-abdominal hypertension and should therefore not be used in high-risk patients during the initial phase after abdominal decompression.
Best, Krista L; Desharnais, Guylaine; Boily, Jeanette; Miller, William C; Camp, Pat G
2012-11-16
Pressure ulcers pose significant negative individual consequences and financial burden on the healthcare system. Prolonged sitting in High Fowler's position (HF) is common clinical practice for older adults who spend extended periods of time in bed. While HF aids in digestion and respiration, being placed in a HF may increase perceived discomfort and risk of pressure ulcers due to increased pressure magnitude at the sacral and gluteal regions. It is likely that shearing forces could also contribute to risk of pressure ulcers in HF. The purpose of this study was to evaluate the effect of a low-tech and time-efficient Trunk Release Manuever (TRM) on sacral and gluteal pressure, trunk displacement and perceived discomfort in ambulatory older adults. A randomized controlled trial was used. We recruited community-living adults who were 60 years of age and older using posters, newspaper advertisements and word-of-mouth. Participants were randomly allocated to either the intervention or control group. The intervention group (n = 59) received the TRM, while the control group (n = 58) maintained the standard HF position. The TRM group had significantly lower mean (SD) PPI values post-intervention compared to the control group, 59.6 (30.7) mmHg and 79.9 (36.5) mmHg respectively (p = 0.002). There was also a significant difference in trunk displacement between the TRM and control groups, +3.2 mm and -5.8 mm respectively (p = 0.005). There were no significant differences in perceived discomfort between the groups. The TRM was effective for reducing pressure in the sacral and gluteal regions and for releasing the trunk at the point of contact between the skin and the support surface, but did not have an effect on perceived discomfort. The TRM is a simple method of repositioning which may have important clinical application for the prevention of pressure ulcers that may occur as a result of HF.
Yeung, Ching-Yan C; Holmes, David F; Thomason, Helen A; Stephenson, Christian; Derby, Brian; Hardman, Matthew J
2016-11-01
Pressure ulcers are complex wounds caused by pressure- and shear-induced trauma to skin and underlying tissues. Pressure-reducing devices, such as dressings, have been shown to successfully reduce pressure ulcer incidence, when used in adjunct to pressure ulcer preventative care. While pressure-reducing devices are available in a range of materials, with differing mechanical properties, understanding of how a material's mechanical properties will influence clinical efficacy remains limited. The aim of this study was to establish a standardized ex vivo model to allow comparison of the cell protection potential of two gel-like pressure-reducing devices with differing mechanical properties (elastic moduli of 77 vs. 35 kPa). The devices also displayed differing energy dissipation under compressive loading, and resisted strain differently under constant load in compressive creep tests. To evaluate biological efficacy we employed a new ex vivo porcine skin model, with a confirmed elastic moduli closely matching that of human skin (113 vs. 119 kPa, respectively). Static loads up to 20 kPa were applied to porcine skin ex vivo with subsequent evaluation of pressure-induced cell death and cytokine release. Pressure application alone increased the percentage of epidermal apoptotic cells from less than 2% to over 40%, and increased cellular secretion of the pro-inflammatory cytokine TNF-alpha. Co-application of a pressure-reducing device significantly reduced both cellular apoptosis and cytokine production, protecting against cellular damage. These data reveal new insight into the relationship between mechanical properties of pressure-reducing devices and their biological effects. After appropriate validation of these results in clinical pressure ulcer prevention with all tissue layers present between the bony prominence and external surface, this ex vivo porcine skin model could be widely employed to optimize design and evaluation of devices aimed at reducing pressure-induced skin damage. © 2016 The Authors Wound Repair and Regeneration published by Wiley Periodicals, Inc. on behalf of The Wound Healing Society.
Negative-pressure wound therapy I: the paradox of negative-pressure wound therapy.
Kairinos, Nicolas; Solomons, Michael; Hudson, Donald A
2009-02-01
Does negative-pressure wound therapy reduce or increase the pressure of wound tissues? This seemingly obvious question has never been addressed by a study on living tissues. The aim of this study was to evaluate the nature of tissue pressure changes in relation to negative-pressure wound therapy. Three negative-pressure wound therapy dressing configurations were evaluated-circumferential, noncircumferential, and those within a cavity-on 15 human wounds, with five wounds in each category. Tissue pressure changes were recorded (using a strain gauge sensor) for each 75-mmHg increment in suction, up to -450 mmHg. In the circumferential and noncircumferential groups, tissue pressure was also measured over a 48-hour period at a set suction pressure of -125 mmHg (n = 10). In all three groups, mean tissue pressure increased proportionately to the amount of suction applied (p < 0.0005). Mean tissue pressure increments resulting from the circumferential dressings were significantly higher than those resulting from the noncircumferential (p < 0.0005) or cavity group (p < 0.0005); however, there was no significant difference between the latter two groups (p = 0.269). Over the 48-hour period, there was a significant mean reduction in the (increased) tissue pressure (p < 0.04 for circumferential and p < 0.0005 for noncircumferential), but in only three of 10 cases did this reduce to pressures less than those before dressing application. Negative-pressure wound therapy increases tissue pressure proportionately to the amount of suction, although this becomes less pronounced over 48 hours. This suggests that negative-pressure wound therapy dressings should be used with caution on tissues with compromised perfusion, particularly when they are circumferential.
Experimental evaluation of the pressure and temperature dependence of ion-induced nucleation.
Munir, Muhammad Miftahul; Suhendi, Asep; Ogi, Takashi; Iskandar, Ferry; Okuyama, Kikuo
2010-09-28
An experimental system for the study of ion-induced nucleation in a SO(2)/H(2)O/N(2) gas mixture was developed, employing a soft x-ray at different pressure and temperature levels. The difficulties associated with these experiments included the changes in physical properties of the gas mixture when temperature and pressure were varied. Changes in the relative humidity (RH) as a function of pressure and temperature also had a significant effect on the different behaviors of the mobility distributions of particles. In order to accomplish reliable measurement and minimize uncertainties, an integrated on-line control system was utilized. As the pressure decreased in a range of 500-980 hPa, the peak concentration of both ions and nanometer-sized particles decreased, which suggests that higher pressure tended to enhance the growth of particles nucleated by ion-induced nucleation. Moreover, the modal diameters of the measured particle size distributions showed a systematic shift to larger sizes with increasing pressure. However, in the temperature range of 5-20 °C, temperature increases had no significant effects on the mobility distribution of particles. The effects of residence time, RH (7%-70%), and SO(2) concentration (0.08-6.7 ppm) on ion-induced nucleation were also systematically investigated. The results show that the nucleation and growth were significantly dependent on the residence time, RH, and SO(2) concentration, which is in agreement with both a previous model and previous observations. This research will be inevitable for a better understanding of the role of ions in an atmospheric nucleation mechanism.
Fici, F; Seravalle, G; Koylan, N; Nalbantgil, I; Cagla, N; Korkut, Y; Quarti-Trevano, F; Makel, W; Grassi, G
2017-09-01
Although improved during the past few years, blood pressure control remains sub optimal. The impact of follow-up assessment on blood pressure control was evaluated in a group of patients of the HYT (HYperTension survey), treated with a combination of different dihydropyridine calcium-channel blockers (CCBs regimen) and inhibitors of renin-angiotensin-aldosterone system (RAAS) and with uncontrolled blood pressure. This was obtained assessing (a) the rate of blood pressure control at 3 and 6 months of follow-up in the whole group of patients, (b) the rate of blood pressure control and the average blood pressure values in subjects treated with different DHP-CCBs regimen. From the 4993 patients with uncontrolled blood pressure, (BP ≥ 140/90 or ≥140/85 in patients with diabetes), 3729 (mean age 61.2 ± 11.5 years), maintained CCBs regimen combined wih RAAS blockers and were evaluated at 3 and 6 months follow-up. At each visit BP (semiautomatic device, Omron-M6, 3 measurements), heart rate, adverse events and treatment persistence were collected. At 1st and 2nd follow-up the rate of controlled BP was 63.5 and 72.8% respectively (p < 0.05 vs 35.3% at baseline), whereas in diabetes was 32.5 and 37.9% respectively (p < 0.05 vs 20% at baseline). No differences in heart rate were observed. No differences in control rate were observed between the different CCBs regimen. The incidence of drugs related adverse events was 3.6%. These findings provide evidence that: (a) the follow-up of hypertensive patients under therapy increase the rate of blood pressure control; (b) there is no significant difference in the antihypertensive effect between different CCBs regimen; (c) lipophilic CCBs induce less ankle edema.
Yildirim, Ali; Kosger, Pelin; Ozdemir, Gokmen; Sahin, Fezan Mutlu; Ucar, Birsen; Kilic, Zubeyir
2015-09-01
A significant correlation between hypertension history and high blood pressure has been observed with regard to age, race and gender. Investigating carotid intima-media thickness and aortic stiffness prior to the development of hypertension in children of hypertensive parents enabled us to evaluate these patients for subclinical atherosclerosis. We compared carotid intima-media thickness, aortic strain, distensibility, stiffness indices and elastic modulus in 67 normotensive children whose parents had a diagnosis of essential hypertension and 39 normotensive children with no parental history of hypertension. Although there were no significant differences between the two groups in terms of systolic blood pressure, diastolic blood pressure, average blood pressure and pulse pressure (P>0.05), systolic blood pressures were higher among patients 15 years and older in the study group. No significant differences were noted between the control and study groups regarding interventricular septal thickness, left-ventricular posterior wall thickness, left-ventricular systolic and diastolic diameter and aortic annulus diameter (P>0.05). The left atrium diameter was larger in the study group compared with that in the control group, mainly because of the values of the 15-year-old and older children (P=0.01). The mean, maximum and minimum values of carotid intima-media thickness were significantly different in the study group compared with the control group among all age groups (P<0.001, P<0.001, P=0.006, respectively). Aortic systolic and diastolic diameters were larger in normotensive children of hypertensive parents compared with the control group (P=0.014, P=0.001, respectively). Although there were no differences between the study and control groups regarding aortic strain, aortic distensibility, elastic modulus and stiffness indices (P>0.05), aortic distensibility was lower, and aortic stiffness indices were higher among children 15 years and older in the study group. An increase in the carotid intima-media thickness in all age groups and a decrease in aortic elastic properties in 15-year-old and older children of hypertensive parents may indicate subclinical atherosclerosis in these apparently healthy children.
Zegarra-Parodi, Rafael; Pazdernik, Vanessa K; Roustit, Matthieu; Park, Peter Yong Soo; Degenhardt, Brian F
2016-02-01
Peripheral skin blood flow (SBF) changes during and after spinal mobilization (SM), evaluated with laser Doppler flowmetry, may document physiological responses associated with SM. To document variations in SBF during and after application of an SM and evaluate influence of pressure on SBF by applying the same standardized SM with 3 different nonnoxious pressures. Cross-over design with 4 interventions on 4 different days: control (no touch) and 3 SMs applied rhythmically at 5%, 40%, or 80% of pain pressure threshold (sham SM, low-pressure SM, or high-pressure SM, respectively). Thirty-two individuals participated. The inspiratory gasp (IG) test was our positive control of vasoconstriction through excitation of the skin sympathetic nervous activity (SSNA). Each session comprised 5 phases: (1) baseline at the end of a 20-min acclimatization, (2) IG test, (3) post-IG phase, (4) SM phase or no manual contact for control, and (5) post-SM phase. A Biopac MP36 system collected SBF data, and a Novel Pliance-X system recorded pressure data. Equal and significant bilateral vasodilation occurred during application of unilateral sham SM, low-pressure SM, and high-pressure SM. Post-SM significant vasodilation persisted after high-pressure SM. The current study is the first to describe bilateral peripheral SBF changes occurring during and 5 min after application of standardized SMs. Our post-SM vasodilation suggests involvement of mechanisms other than the putative SSNA-excitatory mechanism proposed with skin conductance measurements. Persistence of post-SM vasodilation following only high-pressure SM suggests possible pressure-dependent mechanisms. However, further research is warranted to clarify our findings. Copyright © 2015 Elsevier Ltd. All rights reserved.
Özdemir-van Brunschot, Denise M D; Scheffer, Gert J; van der Jagt, Michel; Langenhuijsen, Hans; Dahan, Albert; Mulder, Janneke E E A; Willems, Simone; Hilbrands, Luuk B; Donders, Rogier; van Laarhoven, Cees J H M; d'Ancona, Frank A; Warlé, Michiel C
2017-11-01
The use of low intra-abdominal pressure (<10 mmHg) reduces postoperative pain scores after laparoscopic surgery. To investigate whether low-pressure pneumoperitoneum with deep neuromuscular blockade improves the quality of recovery after laparoscopic donor nephrectomy (LDN). In a single-center randomized controlled trial, 64 live kidney donors were randomly assigned to 6 or 12 mmHg insufflation pressure. A deep neuromuscular block was used in both groups. Surgical conditions were rated by the five-point Leiden-surgical rating scale (L-SRS), ranging from 5 (optimal) to 1 (extremely poor) conditions. If the L-SRS was insufficient, the pressure was increased stepwise. The primary outcome measure was the overall score on the quality of recovery-40 (QOR-40) questionnaire at postoperative day 1. The difference in the QOR-40 scores on day 1 between the low- and standard-pressure group was not significant (p = .06). Also the overall pain scores and analgesic consumption did not differ. Eight procedures (24%), initially started with low pressure, were converted to a standard pressure (≥10 mmHg). A L-SRS score of 5 was significantly more prevalent in the standard pressure as compared to the low-pressure group at 30 min after insufflation (p < .01). Low-pressure pneumoperitoneum facilitated by deep neuromuscular blockade during LDN does not reduce postoperative pain scores nor improve the quality of recovery in the early postoperative phase. The question whether the use of deep neuromuscular blockade during laparoscopic surgery reduces postoperative pain scores independent of the intra-abdominal pressure should be pursued in future studies. The trial was registered at clinicaltrial.gov before the start of the trial (NCT02146417).
de Leeuw, Peter W; Fagard, Robert; Kroon, Abraham A
2017-06-01
This randomized, double-blind, parallel-group, multicenter study compared the efficacy of amlodipine and losartan in an older hypertensive population, focusing on therapeutic coverage in the case of missed doses. Following a 4-week, single-blind, placebo washout period, 211 patients were randomly assigned to receive either 5 mg of amlodipine once daily or 50 mg of losartan once daily. Doses were doubled after 6 weeks of treatment if the diastolic blood pressure exceeded 90 mm Hg. After the 12-week treatment period, patients received the placebo for 2 days (drug holiday) to simulate two missed doses of antihypertensive medication. Twenty-four-hour ambulatory blood pressure monitoring was conducted at the end of the placebo washout period (baseline), upon completion of the 12-week treatment period (steady state), and after the 2-day drug holiday. Amlodipine was more effective than losartan in reducing patients' 24-h ambulatory blood pressure at the steady-state sampling time. The increases in 24-h blood pressure during the drug holiday averaged 6±2/2±1 mm Hg (P<0.0001) in the amlodipine group and 3±2/2±1 mm Hg (P<0.0001) in the losartan group. The rise in systolic pressure was greater in patients on amlodipine than in those on losartan (P<0.0001). For diastolic pressure, the changes did not differ. Owing to the lower pressure during treatment, patients in the amlodipine group remained at a significantly lower blood pressure level after the 2-day drug holiday. Amlodipine was more effective than losartan in lowering blood pressure and in maintaining blood pressure control after two missed doses, and the difference was most significant for systolic blood pressure.
Effect of Intensive Blood-Pressure Treatment on Patient-Reported Outcomes.
Berlowitz, Dan R; Foy, Capri G; Kazis, Lewis E; Bolin, Linda P; Conroy, Molly B; Fitzpatrick, Peter; Gure, Tanya R; Kimmel, Paul L; Kirchner, Kent; Morisky, Donald E; Newman, Jill; Olney, Christine; Oparil, Suzanne; Pajewski, Nicholas M; Powell, James; Ramsey, Thomas; Simmons, Debra L; Snyder, Joni; Supiano, Mark A; Weiner, Daniel E; Whittle, Jeff
2017-08-24
The previously published results of the Systolic Blood Pressure Intervention Trial showed that among participants with hypertension and an increased cardiovascular risk, but without diabetes, the rates of cardiovascular events were lower among those who were assigned to a target systolic blood pressure of less than 120 mm Hg (intensive treatment) than among those who were assigned to a target of less than 140 mm Hg (standard treatment). Whether such intensive treatment affected patient-reported outcomes was uncertain; those results from the trial are reported here. We randomly assigned 9361 participants with hypertension to a systolic blood-pressure target of less than 120 mm Hg or a target of less than 140 mm Hg. Patient-reported outcome measures included the scores on the Physical Component Summary (PCS) and Mental Component Summary (MCS) of the Veterans RAND 12-Item Health Survey, the Patient Health Questionnaire 9-item depression scale (PHQ-9), patient-reported satisfaction with their blood-pressure care and blood-pressure medications, and adherence to blood-pressure medications. We compared the scores in the intensive-treatment group with those in the standard-treatment group among all participants and among participants stratified according to physical and cognitive function. Participants who received intensive treatment received an average of one additional antihypertensive medication, and the systolic blood pressure was 14.8 mm Hg (95% confidence interval, 14.3 to 15.4) lower in the group that received intensive treatment than in the group that received standard treatment. Mean PCS, MCS, and PHQ-9 scores were relatively stable over a median of 3 years of follow-up, with no significant differences between the two treatment groups. No significant differences between the treatment groups were noted when participants were stratified according to baseline measures of physical or cognitive function. Satisfaction with blood-pressure care was high in both treatment groups, and we found no significant difference in adherence to blood-pressure medications. Patient-reported outcomes among participants who received intensive treatment, which targeted a systolic blood pressure of less than 120 mm Hg, were similar to those among participants who received standard treatment, including among participants with decreased physical or cognitive function. (Funded by the National Institutes of Health; SPRINT ClinicalTrials.gov number, NCT01206062 .).
Panda, Brajesh Kumar; Datta, Ashis Kumar
2016-04-01
This study describes major changes in phytochemical composition of orthodox tea (Camellia sinensis var. Assamica) oxidized under compressed air (CA). The experiments for oxidation were conducted under air pressure (101, 202, and 303 kPa) for 150 min. Relative change in the concentrations of caffeine, catechins, theaflavins (TF), and thearubigins (TR) were analyzed. Effect of CA pressure was found to be nonsignificant in regulating caffeine concentration during oxidation. But degradation in different catechins as well as formation of different TF was significantly affected by CA pressure. At high CA pressure, TF showed highest peak value. TR was found to have slower rate of formation during initial phase of oxidation than TF. Even though the rate of TR formation was significantly influenced by CA, a portion of catechins remained unoxidized at end of oxidation. Except caffeine, the percent change in rate of formation or degradation were more prominent at 202 kPa. © 2016 Institute of Food Technologists®
Beeftink, Martine M A; Spiering, Wilko; De Jong, Mark R; Doevendans, Pieter A; Blankestijn, Peter J; Elvan, Arif; Heeg, Jan-Evert; Bots, Michiel L; Voskuil, Michiel
2017-04-01
Renal denervation may be more effective if performed distal in the renal artery because of smaller distances between the lumen and perivascular nerves. The authors reviewed the angiographic results of 97 patients and compared blood pressure reduction in relation to the location of the denervation. No significant differences in blood pressure reduction or complications were found between patient groups divided according to their spatial distribution of the ablations (proximal to the bifurcation in both arteries, distal to the bifurcation in one artery and distal in the other artery, or distal to the bifurcation in both arteries), but systolic ambulatory blood pressure reduction was significantly related to the number of distal ablations. No differences in adverse events were observed. In conclusion, we found no reason to believe that renal denervation distal to the bifurcation poses additional risks over the currently advised approach of proximal denervation, but improved efficacy remains to be conclusively established. ©2017 Wiley Periodicals, Inc.
Forkel, Philipp; Herbort, Mirco; Schulze, Martin; Rosenbaum, Dieter; Kirstein, Lars; Raschke, Michael; Petersen, Wolf
2013-05-01
The purpose of this study was to evaluate the effects of different types of lateral meniscus root tears in terms of tibiofemoral contact stress. Ten porcine knees each underwent five different testing conditions with the menisci intact, a simulated lateral posterior root tear with and without cutting the meniscofemoral ligament and with an artificial tear of the posterior root of the medial meniscus. Biomechanical testing was performed at 30° of flexion with an axial load of 100 N. A pressure sensor (st Sensor Type S2042, Novel, Munich) was used to measure the tibiofemoral contact area and the tibiofemoral contact pressure. Data were analyzed to assess the differences in contact area and tibiofemoral peak contact pressure among the five meniscal conditions. There was no significant difference in mean contact pressure between the state with the menisci intact and an isolated posterior root tear of the lateral meniscus. In case of a root tear and a tear of the meniscofemoral ligament, the contact area decreased in comparison with the intact state of the menisci. After additional cutting of the meniscofemoral ligament, the tibiofemoral contact pressure was significantly higher in comparison with the intact state and the avulsion injury. In the medial compartment, joint compression forces were significantly increased in comparison with the intact state after cutting the posterior root of the medial meniscus (P < 0.05). The consequence of a medial meniscus root tear is well known and was verified by this analysis. The results of the present study show that the biomechanical consequences of a lateral meniscus root tear depend on the state of the meniscofemoral ligament. An increase in tibiofemoral contact pressure is only to be expected in combined injuries of the meniscus root and the meniscofemoral ligaments. Posterior lateral meniscus root tear might have a better prognosis in terms of the development of osteoarthritis when the meniscofemoral ligament is intact.
Lemos, Sandro; Figueiredo, Tiago; Marques, Silvio; Leite, Thalita; Cardozo, Diogo; Willardson, Jeffrey M; Simão, Roberto
2018-01-01
This study compared the effect of a strength training session performed at different exercise orders and rest intervals on blood pressure and heart rate variability (HRV). Fifteen trained men performed different upper body exercise sequences [large to small muscle mass (SEQA) and small to large muscle mass (SEQB)] in randomized order with rest intervals between sets and exercises of 40 or 90 seconds. Fifteen repetition maximum loads were tested to control the training intensity and the total volume load. The results showed, significant reductions for systolic blood pressure (SBP) for all sequences compared to baseline and, post-exercise: SEQA90 at 20, 30, 40, 50 and 60 minutes; SEQA40 and SEQB40 at 20 minutes and SEQB90 at 10, 20, 30, 40, 50 and 60 minutes. For diastolic blood pressure (DBP), significant reductions were found for three sequences compared to baseline and, post-exercise: SEQA90 and SEQA40 at 50 and 60 minutes; SEQB40 at 10, 30 and 60 minutes. For HRV, there were significant differences in frequency domain for all sequences compared to baseline. In conclusion, when performing upper body strength training sessions, it is suggested that 90 second rest intervals between sets and exercises promotes a post-exercise hypotensive response in SBP. The 40 second rest interval between sets and exercises was associated with greater cardiac stress, and might be contraindicated when working with individuals that exhibit symptoms of cardiovascular disease.
Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey
2017-08-01
The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
A comparison of four office chairs using biomechanical measures.
Bush, Tamara Reid; Hubbard, Robert P
2008-08-01
The authors sought to use biomechanical measures, including motion and pressure, to compare four office chairs. The fit of a person to a chair is related to the geometric and kinematic compatibility between the two. This geometric compatibility influences the motions that are allowed or prohibited and the support pressures at the body-chair interface. Thus, during evaluation, it is necessary to treat the chair and user as a system. Four dynamic test conditions were evaluated with 14 participants of varying anthropometries. Test conditions were selected to compare the ability to accommodate primary and secondary motions (recline and spinal articulation) of seated occupants. The ability of a chair to allow recline, yet maintain head and hand positions, was compared across chairs. Also, the ability of each chair to allow and support spinal articulation was evaluated. Motion data for the chair, head, thorax, pelvis, and extremities were collected along with chair back pressures. Upon completion of testing, subjective assessments were also conducted. Statistically significant differences were found between chairs relative to head and hand motions. Also, significant differences were noted for the chairs' ability to move with the body during spinal articulation and the ability to provide support. Subjective assessments also yielded differences. Biomechanical analyses using motions and pressures can be conducted on office chairs with significant differences detected in their performance. Biomechanical assessments can be used to compare and contrast office chairs in terms that are relatable to fatigue reduction as well as operator performance.
Diurnal blood pressure variation in quadriplegic chronic spinal cord injury patients.
Krum, H; Louis, W J; Brown, D J; Jackman, G P; Howes, L G
1991-03-01
1. Measurement of blood pressure and heart rate over a 24 h period was performed in 10 quadriplegic spinal cord injury patients and 10 immobilized, neurologically intact orthopaedic subjects by using the Spacelabs 90207 automated ambulatory monitoring system. 2. Systolic and diastolic blood pressure fell significantly at night in orthopaedic subjects but not in quadriplegic patients, and night-time blood pressures were similar in both groups. 3. Cumulative summation of differences from a reference value (cusum analysis) confirmed a markedly diminished diurnal blood pressure variation in the quadriplegic patients. 4. These findings could not be accounted for on the basis of blood pressure variations during chronic postural change. 5. Heart rate fell significantly at night in both groups. 6. The findings suggest that the increase in blood pressure during waking hours in neurologically intact subjects is a consequence of a diurnal variation in sympathetic activity (absent in quadriplegic patients with sympathetic decentralization) which is independent of changes in physical activity.
The effect of sour tea (Hibiscus sabdariffa) on essential hypertension.
Haji Faraji, M; Haji Tarkhani, A
1999-06-01
Considering the high prevalence of hypertension, its debilitating end organ damage, and the side effects of chemical drugs used for its treatment, we conducted this experimental study to evaluate the effect of sour tea (Hibiscus sabdariffa) on essential hypertension. For this purpose, 31 and 23 patients with moderate essential hypertension were randomly assigned to an experimental and control group, respectively. Patients with secondary hypertension or those consuming more than two drugs were excluded from the study. Systolic and diastolic blood pressures were measured before and 15 days after the intervention. In the experimental group, 45% of the patients were male and 55% were female, and the mean age was 52.6 +/- 7.9 years. In the control group, 30% of the patients were male, 70% were female, and the mean age of the patients was 51.5 +/- 10.1 years. Statistical findings showed an 11.2% lowering of the systolic blood pressure and a 10.7% decrease of diastolic pressure in the experimental group 12 days after beginning the treatment, as compared with the first day. The difference between the systolic blood pressures of the two groups was significant, as was the difference of the diastolic pressures of the two groups. Three days after stopping the treatment, systolic blood pressure was elevated by 7.9%, and diastolic pressure was elevated by 5.6% in the experimental and control groups. This difference between the two groups was also significant. This study proves the public belief and the results of in vitro studies concerning the effects of sour tea on lowering high blood pressure. More extensive studies on this subject are needed.
Jiang, Nancy; Del Signore, Anthony G; Iloreta, Alfred M; Malkin, Benjamin D
2013-08-01
The purpose of this study was to evaluate the efficacy of a novel teaching tool to improve health care providers' ability to inflate tracheostomy tube cuffs to the appropriate pressure. Single-blinded, randomized, controlled trial. Subjects were randomized to a control and study group. The control group viewed a video about inflating tracheostomy tube cuffs to safe pressure levels. The study group viewed the same video and also got to palpate the pilot balloons of tracheostomy tube cuffs inflated to three different pressures. All subjects inflated tracheostomy tube cuffs to pressures they believed to be appropriate based on palpation of the pilot balloon preintervention, and immediately, 2 weeks, and 3 months postintervention. Forty-nine health care providers participated in the study. There was no significant difference in the mean preintervention cuff inflation pressures between the two groups (36 cm H2 O vs. 38 cm H2 O, P = 0.4888), with both initially overinflating. Postintervention, the study group inflated the cuffs to significantly lower pressures than the control group, closer to the ideal of 25 cm H2 O (26 cm H2 O vs. 35 cm H2 O, P = 0.0001). This difference was also observed 2 weeks (28 cm H2 O vs. 37 cm H2 O P <0.0001) and 3 months (28 cm H2 O vs. 36 cm H2 O, P = 0.0002) postintervention. The novel teaching tool evaluated in this study is simple, easily reproducible, and low-cost. Its use leads to long-lasting improvement in health care providers' ability to more accurately inflate tracheostomy tube cuffs to safe pressures. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Two-phase flows within systems with ambient pressure
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Braun, M. J.; Wheeler, R. L., III; Mullen, R. L.
1985-01-01
In systems where the design inlet and outlet pressures are maintained above the thermodynamic critical pressure, it is often assumed that two phase flows within the system cannot occur. Designers rely on this simple rule of thumb to circumvent problems associated with a highly compressible two phase flow occurring within the supercritical pressure system along with the uncertainties in rotordynamics, load capacity, heat transfer, fluid mechanics, and thermophysical property variations. The simple rule of thumb is adequate in many low power designs but is inadequate for high performance turbomachines and linear systems, where two phase regions can exist even though outlet pressure is greater than critical pressure. Rotordynamic-fluid-mechanic restoring forces depend on momentum differences, and those for a two phase zone can differ significantly from those for a single-phase zone. Using the Reynolds equation the angular velocity, eccentricity, geometry, and ambient conditions are varied to determine the point of two phase flow incipience.
Dasinger, John Henry; Intapad, Suttira; Backstrom, Miles A.; Carter, Anthony J.
2016-01-01
Placental insufficiency programs an increase in blood pressure associated with a twofold increase in serum testosterone in male growth-restricted offspring at 4 mo of age. Population studies indicate that the inverse relationship between birth weight and blood pressure is amplified with age. Thus, we tested the hypothesis that intrauterine growth restriction programs an age-related increase in blood pressure in male offspring. Growth-restricted offspring retained a significantly higher blood pressure at 12 but not at 18 mo of age compared with age-matched controls. Blood pressure was significantly increased in control offspring at 18 mo of age relative to control counterparts at 12 mo; however, blood pressure was not increased in growth-restricted at 18 mo relative to growth-restricted counterparts at 12 mo. Serum testosterone levels were not elevated in growth-restricted offspring relative to control at 12 mo of age. Thus, male growth-restricted offspring no longer exhibited a positive association between blood pressure and testosterone at 12 mo of age. Unlike hypertension in male growth-restricted offspring at 4 mo of age, inhibition of the renin-angiotensin system with enalapril (250 mg/l for 2 wk) did not abolish the difference in blood pressure in growth-restricted offspring relative to control counterparts at 12 mo of age. Therefore, these data suggest that intrauterine growth restriction programs an accelerated age-related increase in blood pressure in growth-restricted offspring. Furthermore, this study suggests that the etiology of increased blood pressure in male growth-restricted offspring at 12 mo of age differs from that at 4 mo of age. PMID:27147668
Weston, Kassia S; Sacre, Julian W; Jellis, Christine L; Coombes, Jeff S
2013-01-01
The purpose of this study was to compare the presence and severity of autonomic dysfunction in type 2 diabetes mellitus patients, with and without exaggerated blood pressure responses to exercise. We performed a cross-sectional analysis of 98 patients with type 2 diabetes mellitus (aged 59±9). Both time (standard deviation of RR intervals, root-mean-square of successive RR interval differences) and frequency (total spectral power, high frequency, low frequency, very low frequency) domains of heart rate variability were analysed in a 5 min recording at rest and 20 min after a maximal treadmill test. An exaggerated blood pressure response to exercise was identified by peak blood pressure ≥190/105 mmHg (women) or ≥210/105 mmHg (men). Each group of either exaggerated exercise blood pressure response or normal blood pressure response consisted of 49 patients. At rest there were no significant differences between groups for all time and frequency domain parameters of heart rate variability. Post-exercise, there was a significant (p<0.05) reduction in the SDNN, RMSSD and TP in the exaggerated exercise blood pressure group. Independent correlates (p<0.01) of exercise systolic blood pressure included post-exercise TP, resting systolic blood pressure, cardiac autonomic neuropathy and beta-blockers (beta=-0.28, adj. R² = 0.32, p<0.001). Reduced post-exercise heart rate variability in patients with type 2 diabetes mellitus, with an exaggerated exercise blood pressure response suggests preclinical autonomic dysfunction characterized by impaired vagal modulation. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Technical characteristics can make the difference in a surgical linear stapler. Or not?
Giaccaglia, Valentina; Antonelli, Maria Serena; Addario Chieco, Paola; Cocorullo, Gianfranco; Cavallini, Marco; Gulotta, Gaspare
2015-07-01
Anastomotic leak (AL) after gastrointestinal surgery is a severe complication associated with relevant short- and long-term sequelae. Most of the anastomosis are currently performed with a surgical stapler that is required to have appropriate characteristics to guarantee good performances. The aim of our study was to evaluate, in the laboratory, pressure resistance and tensile strength of anastomosis performed with different surgical linear staplers, available in the market. We have been studying three linear staplers, with diverse cartridges and staple heights, of three different companies, used for gastrointestinal anastomosis and gastric or intestinal closure. We performed 50 anastomosis for each device, with the pertinent different cartridges, on fresh pig intestine, for a total of 350 anastomosis, then injected saline solution and recorded the pressure that provokes a leak on the staple line. There were no statistically significant differences between the mean pressure necessary to induce an AL in the various instruments (P > 0.05). For studying the tensile strength, we performed a total of 350 anastomosis with the different linear staplers on a special strong paper (Tyvek), then recorded the maximal tensile force that could open the anastomosis. There were no statistically significant differences between the different staplers about the strength necessary to open the staple line (P > 0.05). we demonstrated that different linear staplers of three companies available in the market give comparable anastomotic pressure resistance and tensile strength. This might suggest that small dissimilarities between different devices are not involved, at least as major parameters, in AL etiology. Copyright © 2015 Elsevier Inc. All rights reserved.
Hakami, A; Santamore, W P; Stremel, R W; Tobin, G; Hjortdal, V E
1999-08-01
Dynamic aortomyoplasty using Latissimus Dorsi muscle (LDM) has been shown to improve myocardial function. However, systematic examination of the effects of stimulation parameters on aortic wrap function has not been done. Thus, the present study measures the direct effect of stimulation voltage, pulse train duration, frequency of the pulses, and the duration of the stimulation delay from R wave on the aortic wrap function. In eight female goats, the left LDM was wrapped around the descending aorta. The muscle was then subjected to electrical stimulation, altering frequency of stimulation pulses (16.6, 20, 25, 33 and 50 Hz), amplitude (2, 4, 6, 8 and 10 V), and number of pulses (2, 4, 6, 8 and 10 pulses) in a train stimulation. Left ventricular, aortic pressure, and pressure generated by LDM on aorta (wrap pressure) was measured. The changes in hemodynamic parameters mentioned above were calculated and compared for different stimulation parameters during unassisted and assisted cardiac cycles. Aortomyoplasty counterpulsation using LDM provided significant improvement in wrap pressure (78 mmHg +/- 2), aortic diastolic pressure, and changes in aortic diastolic pressure from 2 to 4 V (P < 0.05). Further increase in amplitude did not make any significant improvements of the above mentioned parameters. Significant augmentation of wrap pressure (82 mmHg +/- 2), aortic diastolic pressure (79 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) occurred at 6 pulses (P < 0.05). Other changes in number of pulses did not show any significant improvements. Significant improvement of wrap pressure (80 mmHg +/- 2), aortic diastolic pressure (73 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) was observed with a frequency of 33 Hz. To examine a wide range of delays from the onset of the QRS complex to LDM stimulation, stimulation was delivered randomly. The exact delay was determined from the ECG signal and superimposed LDM stimulation pulses. In this study we present a new measurement, wrap pressure. We also present that in aortomyoplasty using LDM, the most significant improvement in wrap pressure, aortic diastolic pressure and changes in aortic diastolic pressure occurs when the stimulation consists of an amplitude of 4 V, a frequency of 33 Hz and a train stimulation of 6 pulses.
Frič, Radek; Lindstrøm, Erika Kristina; Ringstad, Geir Andre; Mardal, Kent-André; Eide, Per Kristian
2016-12-01
In symptomatic Chiari malformation type 1 (CMI), impaired intracranial compliance (ICC) is associated with an increased cranio-spinal pulsatile pressure gradient. Phase-contrast magnetic resonance imaging (MRI) represents a non-invasive modality for the assessment of the pulse pressure gradient at the cranio-cervical junction (CCJ). We wished to explore how the MRI-derived pulse pressure gradient (MRI-dP) compares with invasively measured pulsatile intracranial pressure (ICP) in CMI, and with healthy controls. From phase-contrast MRI of CMI patients and healthy controls, we computed cerebrospinal fluid (CSF) flow velocities and MRI-dP at the CCJ. We assessed bidirectional flow and compared the flow between the anterior and the posterior subarachnoid space at the CCJ. We computed total intracranial volume (ICV), ventricular CSF volume (VV), and posterior cranial fossa volume (PCFV). We analyzed the static and pulsatile ICP scores from overnight monitoring in CMI patients. Five CMI patients and four healthy subjects were included. The CMI group had a significantly larger extent of tonsillar ectopia, smaller PCFV, and a smaller area of CSF in the FM. The pulsatile ICP (mean ICP wave amplitude, MWA) was abnormally increased in 4/5 CMI patients and correlated positively with MRI-dP. However, the MRI-dP as well as the CSF flow velocities did not differ significantly between CMI and healthy subjects. Moreover, bidirectional flow was observed in both CMI as well as healthy subjects, with no significant difference. In symptomatic CMI patients, we found a significant association between the pulse pressure gradient at the CCJ derived from phase-contrast MRI and the pulsatile ICP (MWA) measured invasively. However, the MRI-dP was close to identical in CMI patients and healthy subjects. Moreover, the CSF flow velocities at the CCJ and the occurrence of bidirectional flow were not different in CMI patients and healthy individuals. Further studies are required to determine the diagnostic role of phase-contrast MRI in CMI patients.
Thermally Driven Josephson Effect
NASA Technical Reports Server (NTRS)
Penanen, Konstantin; Chui, Talso
2008-01-01
A concept is proposed of the thermally driven Josephson effect in superfluid helium. Heretofore, the Josephson effect in a superfluid has been recognized as an oscillatory flow that arises in response to a steady pressure difference between two superfluid reservoirs separated by an array of submicron-sized orifices, which act in unison as a single Josephson junction. Analogously, the thermally driven Josephson effect is an oscillatory flow that arises in response to a steady temperature difference. The thermally driven Josephson effect is partly a consequence of a quantum- mechanical effect known as the fountain effect, in which a temperature difference in a superfluid is accompanied by a pressure difference. The thermally driven Josephson effect may have significance for the development of a high-resolution gyroscope based on the Josephson effect in a superfluid: If the pressure-driven Josephson effect were used, then the fluid on the high-pressure side would become depleted, necessitating periodic interruption of operation to reverse the pressure difference. If the thermally driven Josephson effect were used, there would be no net flow and so the oscillatory flow could be maintained indefinitely by maintaining the required slightly different temperatures on both sides of the junction.
Skrzypecki, Janusz; Gawlak, Maciej; Huc, Tomasz; Szulczyk, Paweł; Ufnal, Marcin
2017-01-01
The effect of renal denervation on the efficacy of antihypertensive drugs has not yet been elucidated. Twenty-week-old spontaneously hypertensive rats were treated with metoprolol, losartan, indapamide, or saline (controls) and assigned to renal denervation or a sham procedure. Acute hemodynamic measurements were performed ten days later. Series showing a significant interaction between renal denervation and the drugs were repeated with chronic telemetry measurements. In the saline series, denervated rats showed a significantly lower mean arterial blood pressure (blood pressure) than the sham-operated rats. In contrast, in the metoprolol series denervated rats showed a significantly higher blood pressure than sham rats. There were no differences in blood pressure between denervated and sham rats in the losartan and indapamide series. In chronic studies, a 4-week treatment with metoprolol caused a decrease in blood pressure. Renal denervation and sham denervation performed 10 days after the onset of metoprolol treatment did not affect blood pressure. Denervated rats showed markedly reduced renal nerve tyrosine hydroxylase levels. In conclusion, renal denervation decreases blood pressure in hypertensive rats. The hypotensive action of metoprolol, indapamide, and losartan is not augmented by renal denervation, suggesting the absence of synergy between renal denervation and the drugs investigated in this study.
Analysis of sub-bandage pressure of compression bandages during exercise.
Kumar, B; Das, A; Alagirusamy, R
2012-11-01
The sub-bandage pressure produced by any compression bandaging system is likely to vary during the physical activities taken by the patient. It is of significant importance to understand the variation of sub-bandage pressure during the exercise of calf muscle pump. The present paper aims to analyse the dominating factors and their interactions on the sub-bandage pressure during exercise. In this work the circumferential change of the leg because of the exercise of the calf muscle pump (expansion or contraction) is simulated using expansion or contraction actions of an air bladder placed on a mannequin. The study has been carried out using an indigenously developed prototype by pumping or squeezing of air in air bladder using cylinder-piston arrangement. A series of commercially available bandages were studied and the impact of the major factors, namely bandage extensibility (E), bandage tension (T) and the amount of bladder expansion or contraction (A) on the sub-bandage pressure during one cycle of expansion or contraction of air bladder have been analysed. Different levels of the factors have been chosen and a complete factorial design was prepared to obtain the sub-bandage pressure at all combination of the levels of the factors. The results showed that the sub-bandage pressure variations were higher for short-stretch bandage under dynamic mode (p value < 0.05). The variation in sub-bandage pressure were increased by increasing the amount of expansion or contraction of the air bladder and also increased when the bandage was wrapped at higher tension level (p-value < 0.05). N-way ANOVA results showed that some of the interactions effects of these above factors (EA and AT) also significantly affecting the sub-bandage pressure variations (p-value < 0.05). The prototype provides a simpler method to assess the bandage behaviour under different conditions without doing in vivo sub-bandage pressure measurement, and hence could be used to evaluate and compare the effectiveness of different compression bandage under different conditions, prior to their application on the wounded leg. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Yu, S-X; Zhang, Q-S; Yin, Y; Liu, Z; Wu, J-M; Yang, M-X
2016-11-01
This study evaluates the value of continuous dynamic monitoring of intracranial pressure (ICP) in patients with hypertensive intracerebral hemorrhage to predict early postoperative complications. Data from 80 patients treated in our hospital from February 2014 to February 2015 were analyzed. The patients all underwent decompressive craniectomies, and their ICP changes were monitored invasively and continuously for 1 to 7 days after surgery. The average blood loss during surgery for the group of patients was 65.3 ± 12.4 ml and the mean GCS score 8.7 ± 2.4. Cases were divided into three groups according to ICP values to compare early postoperative complications of the groups: a normal and mildly increased group (51 cases), a moderately increased group (19 cases) and a severely increased group (10 cases). To validate the analysis we first showed that comparisons among groups based on gender, age, systolic pressure, diastolic pressure, bleeding time, blood loss, operation time, craniectomy localization, and preoperative mannitol dosage yielded no statistically significant differences. In contrast, the following comparisons produced statistically significant differences: the comparison of postoperative Glasgow Coma Scale (GCS) scores showing that the lower intracranial pressure, the higher the GCS score; the postoperative rehemorrhage, cerebral edema and death ratios showing the higher the intracranial pressure, the higher the rehemorrhage ratio; the average ICP and the time to occurrence of rehemorrhage, cerebral edema or cerebral infarction, showing the relationship between the average ICP and the time to a complication. Patients with higher ICP averages suffered a complication of rehemorrhage within the first 9.6 ± 2.5 hours on average. Nevertheless, the comparison of GCS scores in those patients and the others showed no significant differences. Based on the findings, the dynamic monitoring of intracranial pressure can early and sensitively predict postoperative complications of patients with hypertensive cerebral hemorrhage, and guide the clinical intervention actively to improve the surgery outcome.
Cené, Crystal W; Halladay, Jacqueline R; Gizlice, Ziya; Donahue, Katrina E; Cummings, Doyle M; Hinderliter, Alan; Miller, Cassandra; Johnson, Larry F; Garcia, Beverly; Tillman, Jim; Little, Edwin P; Rachide, Marjorie R; Keyserling, Thomas C; Ammerman, Alice; Zhou, Haibo; Wu, Jia-Rong; DeWalt, Darren
2017-04-01
The Southeastern United States has the highest prevalence of hypertension and African Americans have disproportionately worse blood pressure control. The authors sought to evaluate the effect of a multicomponent practice-based quality improvement intervention on lowering mean systolic blood pressure (SBP) at 12 and 24 months compared with baseline among 525 patients, and to assess for a differential effect of the intervention by race (African Americans vs white). At 12 months, both African Americans (-5.0 mm Hg) and whites (-7.8 mm Hg) had a significant decrease in mean SBP compared with baseline, with no significant between-group difference. Similarly, at 24 months, mean SBP decreased in both African Americans (-6.0 mm Hg) and whites (-7.2 mm Hg), with no significant difference between groups. Notably, no significant racial disparity in mean SBP at baseline was shown. The intervention was effective in lowering mean SBP in both African Americans and whites but there was no differential effect of the intervention by race. ©2016 Wiley Periodicals, Inc.
Chen, Hong-Lin; Cao, Ying-Juan; Wang, Jing; Huai, Bao-Sha
2015-09-01
The Braden Scale is the most widely used pressure ulcer risk assessment in the world, but the currently used 5 risk classification groups do not accurately discriminate among their risk categories. To optimize risk classification based on Braden Scale scores, a retrospective analysis of all consecutively admitted patients in an acute care facility who were at risk for pressure ulcer development was performed between January 2013 and December 2013. Predicted pressure ulcer incidence first was calculated by logistic regression model based on original Braden score. Risk classification then was modified based on the predicted pressure ulcer incidence and compared between different risk categories in the modified (3-group) classification and the traditional (5-group) classification using chi-square test. Two thousand, six hundred, twenty-five (2,625) patients (mean age 59.8 ± 16.5, range 1 month to 98 years, 1,601 of whom were men) were included in the study; 81 patients (3.1%) developed a pressure ulcer. The predicted pressure ulcer incidence ranged from 0.1% to 49.7%. When the predicted pressure ulcer incidence was greater than 10.0% (high risk), the corresponding Braden scores were less than 11; when the predicted incidence ranged from 1.0% to 10.0% (moderate risk), the corresponding Braden scores ranged from 12 to 16; and when the predicted incidence was less than 1.0% (mild risk), the corresponding Braden scores were greater than 17. In the modified classification, observed pressure ulcer incidence was significantly different between each of the 3 risk categories (P less than 0.05). However, in the traditional classification, the observed incidence was not significantly different between the high-risk category and moderate-risk category (P less than 0.05) and between the mild-risk category and no-risk category (P less than 0.05). If future studies confirm the validity of these findings, pressure ulcer prevention protocols of care based on Braden Scale scores can be simplified.
Pulmonary capillary pressure in pulmonary hypertension.
Souza, Rogerio; Amato, Marcelo Britto Passos; Demarzo, Sergio Eduardo; Deheinzelin, Daniel; Barbas, Carmen Silvia Valente; Schettino, Guilherme Paula Pinto; Carvalho, Carlos Roberto Ribeiro
2005-04-01
Pulmonary capillary pressure (PCP), together with the time constants of the various vascular compartments, define the dynamics of the pulmonary vascular system. Our objective in the present study was to estimate PCPs and time constants of the vascular system in patients with idiopathic pulmonary arterial hypertension (IPAH), and compare them with these measures in patients with acute respiratory distress syndrome (ARDS). We conducted the study in two groups of patients with pulmonary hypertension: 12 patients with IPAH and 11 with ARDS. Four methods were used to estimate the PCP based on monoexponential and biexponential fitting of pulmonary artery pressure decay curves. PCPs in the IPAH group were considerably greater than those in the ARDS group. The PCPs measured using the four methods also differed significantly, suggesting that each method measures the pressure at a different site in the pulmonary circulation. The time constant for the slow component of the biexponential fit in the IPAH group was significantly longer than that in the ARDS group. The PCP in IPAH patients is greater than normal but methodological limitations related to the occlusion technique may limit interpretation of these data in isolation. Different disease processes may result in different times for arterial emptying, with resulting implications for the methods available for estimating PCP.
The Relationship Between Monthdisease Incidence Rate and Climatic Factor of Classical Swine Fever
NASA Astrophysics Data System (ADS)
Wang, Hongbin; Xu, Danning; Xiao, Jianhua; Zhang, Ru; Dong, Jing
The Swine Fever is a kind of acute, highly infective epidemic disease of animals; it is name as Classical Swine Fever (CSF) by World animal Health organization. Meteorological factors such as temperature, air pressure and rainfall affect the epidemic of CSF significantly through intermediary agent and CSF viral directly. However there is significant difference among different region for mode of effects. Accordingly, the analyze must adopt different methods. The dependability between incidence rate each month of CSF and meteorological factors from 1999 to 2004 was analyzed in this paper. The function of meteorological factors on CSF was explored and internal law was expected to be discovered. The correlation between the incidence rate of Swine Fever and meteorological factors, thus the foundation analysis of the early warning and the decision-making was made, the result indicated that the incidence rate of CSF has negative correlation with temperature, rainfall, cloudage; relative humidity has positive correlation with disease; for air pressure, except average air pressure of one month, other air pressure factors have positive correlation with disease; for wind speed, except Difference among moths of wind speed and average temperature of one month. have positive correlation with disease, other wind speed factors has negative correlation with disease.
Gomes, Adriana de Oliveira; Silvestre, Ana Caroline; da Silva, Cristina Ferreira; Gomes, Mariany Ribeiro; Bonfleur, Maria Lúcia; Bertolini, Gladson Ricardo Flor
2014-01-01
Objective To investigate the effects of different transcutaneous electrical nerve stimulation frequencies in nociception front of a pressure pain threshold and cold in healthy individuals. Methods Twenty healthy subjects were divided into four groups, all of which have gone through all forms of electrical stimulation at different weeks. Assessments were pre and post-therapy, 20 and 60 minutes after stimulation. To evaluate the pressure pain threshold, an algometer was used with one tapered tip, pressing the hypothenar region until voluntary report the word “pain”. Cold pain intensity was assessed by immersion in water at 5°C for 30 seconds; at the end, the subject was asked to quantify the pain intensity on a Visual Analog Scale for Pain. For electrical stimulation, two electrodes were used near the elbow, for 20 minutes, with an intensity strong, but not painful. The frequency was in accordance with the group: 0Hz (placebo); 7Hz; 100Hz; and 255Hz. Results Both for the assessment of pressure pain threshold as the cold pain intensity, there was no significant difference (p>0.05). Conclusion We conclude that the use of transcutaneous electrical nerve stimulation on dermatomes C6 to C8 produced no significant change in pressure pain threshold or cold discomfort. PMID:25295453
Cerebral Pulsatility Index Is Elevated in Patients with Elevated Right Atrial Pressure.
Lahiri, Shouri; Schlick, Konrad H; Padrick, Matthew M; Rinsky, Brenda; Gonzalez, Nestor; Jones, Heather; Mayer, Stephan A; Lyden, Patrick D
2018-01-01
Extracerebral venous congestion can precipitate intracranial hypertension due to obstruction of cerebral blood outflow. Conditions that increase right atrial pressure, such as hypervolemia, are thought to increase resistance to jugular venous outflow and contribute to cerebro-venous congestion. Cerebral pulsatility index (CPI) is considered a surrogate marker of distal cerebrovascular resistance and is elevated with intracranial hypertension. Thus, we sought to test the hypothesis that elevated right atrial pressure is associated with increased CPI compared to normal right atrial pressure. We retrospectively reviewed 61 consecutive patients with subarachnoid hemorrhage. We calculated CPI from transcranial Doppler studies and correlated these with echocardiographic measures of right atrial pressure. CPIs were compared from patients with elevated and normal right atrial pressure. There was a significant difference between CPI obtained from all patients with elevated right atrial pressure compared to those with normal right atrial pressure (P < .0001). This finding was consistent in sensitivity analysis that compared right and left hemispheric CPI from patients with both elevated and normal right atrial pressure. Patients with elevated right atrial pressure had significantly higher CPI compared to patients with normal right atrial pressure. These findings suggest that cerebro-venous congestion due to impaired jugular venous outflow may increase distal cerebrovascular resistance as measured by CPI. Since elevated CPI is associated with poor outcome in numerous neurological conditions, future studies are needed to elucidate the significance of these results in other populations. Copyright © 2017 by the American Society of Neuroimaging.
Comparison between deep breathing exercises and incentive spirometry after CABG surgery.
Renault, Julia Alencar; Costa-Val, Ricardo; Rosseti, Márcia Braz; Houri Neto, Miguel
2009-01-01
To compare the effects of deep breathing exercises (DBE) and the flow-oriented incentive spirometry (IS) in patients undergone coronary artery bypass grafting (CABG) through the following variables: forced vital capacity - FVC, forced expiratory volume in 1 second - FEV(1), maximal respiratory pressures and oxygen saturation. Thirty six patients in CABG postoperative period underwent thirty minutes of non-invasive ventilation during the first 24 hours after extubation and were randomly shared into two groups as following: DBE (n=18) and IS (n=18). The spirometric variables were assessed on the preoperative period and seventh postoperative day (POD). The respiratory muscle strength and oxygen saturation were assessed on the preoperative period, first, second and seventh POD. The groups were considered homogeneous in relation to the demographic and surgical variables. It has been noted fall in the values of FVC and FEV(1) between the preoperative period and the seventh POD, but without significant differences between groups. The maximal respiratory pressures showed drop in the first POD but with and partial recovery until the seventh POD, also without significant differences between groups. The oxygen saturation was the only variable that was completely recovered on the seventh POD, also without significant differences between groups. There were not observed significant differences in maximal respiratory pressures, spirometric variables and oxygen saturation in patients undergone deep breathing exercises and flow-oriented incentive spirometry after coronary artery bypass grafting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colby, Robert J.; Alsem, Daan H.; Liyu, Andrey V.
2015-06-01
The development of environmental transmission electron microscopy (TEM) has enabled in situ experiments in a gaseous environment with high resolution imaging and spectroscopy. Addressing scientific challenges in areas such as catalysis, corrosion, and geochemistry can require pressures much higher than the ~20 mbar achievable with a differentially pumped, dedicated environmental TEM. Gas flow stages, in which the environment is contained between two semi-transparent thin membrane windows, have been demonstrated at pressures of several atmospheres. While this constitutes significant progress towards operando measurements, the design of many current gas flow stages is such that the pressure at the sample cannot necessarilymore » be directly inferred from the pressure differential across the system. Small differences in the setup and design of the gas flow stage can lead to very different sample pressures. We demonstrate a method for measuring the gas pressure directly, using a combination of electron energy loss spectroscopy and TEM imaging. This method requires only two energy filtered TEM images, limiting the measurement time to a few seconds and can be performed during an ongoing experiment at the region of interest. This approach provides a means to ensure reproducibility between different experiments, and even between very differently designed gas flow stages.« less
Non-axisymmetric flow characteristics in centrifugal compressor
NASA Astrophysics Data System (ADS)
Wang, Leilei; Lao, Dazhong; Liu, Yixiong; Yang, Ce
2015-06-01
The flow field distribution in centrifugal compressor is significantly affected by the non-axisymmetric geometry structure of the volute. The experimental and numerical simulation methods were adopted in this work to study the compressor flow field distribution with different flow conditions. The results show that the pressure distributionin volute is characterized by the circumferential non-uniform phenomenon and the pressure fluctuation on the high static pressure zone propagates reversely to upstream, which results in the non-axisymmetric flow inside the compressor. The non-uniform level of pressure distribution in large flow condition is higher than that in small flow condition, its effect on the upstream flow field is also stronger. Additionally, the non-uniform circumferential pressure distribution in volute brings the non-axisymmetric flow at impeller outlet. In different flow conditions,the circumferential variation of the absolute flow angle at impeller outlet is also different. Meanwhile, the non-axisymmetric flow characteristics in internal impeller can be also reflected by the distribution of the mass flow. The high static pressure region of the volute corresponds to the decrease of mass flow in upstream blade channel, while the low static pressure zone of the volute corresponds to the increase of the mass flow. In small flow condition, the mass flow difference in the blade channel is bigger than that in the large flow condition.
Liu, Su-Meng; Wang, Ning-Li; Zuo, Zhen-Tao; Chen, Wei-Wei; Yang, Di-Ya; Li, Zhen; Cao, Yi-Wen
2018-02-01
In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can relieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 ± 0.1 mm (range: 0.77-1.05 mm), 0.77 ± 0.11 mm (range: 0.60-0.94 mm), 0.70 ± 0.08 mm (range: 0.62-0.80 mm), and 0.68 ± 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the intraocular pressure before, during and after the intra-abdominal pressure elevation. These results verified that the increased intra-abdominal pressure widens the orbital subarachnoid space in this acute trial, but does not alter the intraocular pressure, indicating that intraocular pressure is not affected by rapid increased intra-abdominal pressure. This study was registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-ONRC-14004947).
König, Nico; Paulus, Michael; Julius, Karin; Schulze, Julian; Voetz, Matthias; Tolan, Metin
2017-12-01
In the present work two subclasses of the human antibody Immunoglobulin G (IgG) have been investigated by Small-Angle X-ray Scattering under high hydrostatic pressures up to 5kbar. It is shown that IgG adopts a symmetric T-shape in solution which differs significantly from available crystal structures. Moreover, high-pressure experiments verify the high stability of the IgG molecule. It is not unfolded by hydrostatic pressures of up to 5kbar but a slight increase of the radius of gyration was observed at elevated pressures. Copyright © 2017 Elsevier B.V. All rights reserved.
The Effect of Labor on the Intraocular Pressure in Healthy Women.
Meshi, Amit; Armarnik, Sharon; Mimouni, Michael; Segev, Fani; Segal, Ori; Kaneti, Hagai; Assia, Ehud I; Geffen, Noa
2017-01-01
To investigate the effect of modern vaginal labor using epidural anesthesia on the intraocular pressure (IOP) and on the mean ocular perfusion pressure (MOPP) in healthy women. In this prospective observational study, eligible candidates were healthy pregnant women for vaginal delivery with epidural anesthesia, with a singleton pregnancy, who were admitted to the delivery room in the first phase of the first stage of labor. Demographic data as well as medical and obstetric history were obtained at baseline, followed by performance of a biomicroscopic examination. IOP, maternal heart rate, systolic blood pressure, and diastolic blood pressure were measured in the first, second and third stages of labor, 24±2 and 48±2 hours postpartum. IOP was not measured during the contraction phase of stage 2. MOPP was expressed as the difference between the arterial blood pressure and the IOP. Measurements were performed throughout the different stages of labor and were compared with baseline values. Thirty healthy white women were enrolled. Four women dropped out due to unexpected cesarean sections. The average age was 31.8±4.7 years. Nineteen participants received oxytocin during delivery. Twenty-three women were placed in a supine position, whereas 3 in a left decubitus position. No statistically significant changes were recorded in IOP (P=0.50) or MOPP (P=0.17) throughout the different stages of vaginal labor in this study. Vaginal delivery under epidural anesthesia is unlikely to cause significant damage to the optic nerve in healthy women.
Jiao, Rui; Gao, Jina; Li, Yinxiang; Zhang, Xiyan; Zhang, Maofeng; Ye, Yingwang; Wu, Qingping; Fan, Hongying
2016-10-01
Powdered infant formula is considered as the main transmission vehicle for Cronobacter sakazakii infections including meningitis, septicemia, and necrotizing enterocolitis. The effects of high-pressure processing treatment on inactivation of C. sakazakii ranging from 100 to 400 MPa for 3.0, 5.0, and 7.0 min in whole milk and skim milk were studied. Significant differences in inactivation of C. sakazakii were observed in milk samples under different pressures for 3 to 7 min compared with untreated samples, and C. sakazakii was not detected after 400 MPa for 3 min. The lethality rates of C. sakazakii cells in whole and skim milk with an initial level of 10(4) cfu/mL after 100 and 200 MPa treatments were not significantly different, but relatively higher lethality rates were found in whole milk after 300 MPa treatment than in skim milk. Finally, the scanning electron micrographs indicated that cellular envelope and intracellular damage of C. sakazakii cells were apparent after 300 and 400 MPa for 5.0 min compared with the untreated cells, and a progressive increase of injured cells with increased pressure treatment was found. It was concluded that C. sakazakii was sensitive to high-pressure processing treatment and that high-pressure processing treatment with 400 MPa for 3.0 min can be used to control C. sakazakii contamination in milk samples. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Nisenbaum, Marcelo Gil; de Melo, Nilson Roberto; Giribela, Cassiana Rosa Galvão; de Morais, Tércio Lemos; Guerra, Grazia Maria; de Angelis, Katia; Mostarda, Cristiano; Baracat, Edmund Chada; Consolim-Colombo, Fernanda Marciano
2014-04-01
The use of combined oral contraceptives has been associated with an increased risk of adverse cardiovascular events. Whether these drugs alter cardiac autonomic nervous system control is not completely determined. To evaluate the effect of a contraceptive containing 20mcg of ethinyl estradiol and 3mg of drospirenone on the heart rate variability, baroreflex sensitivity and blood pressure of healthy women. Prospective controlled trial with 69 healthy women allocated in two groups: 36 volunteers under oral combined contraceptive use and 33 volunteers using of non-hormonal contraceptive methods. Subjects were tested before the introduction of the contraceptive method and 6 months after its use. For data acquisition, we used continuous non-invasive beat-to-beat blood pressure curve recordings. Multiple ANOVA was used to determine differences between groups and moments and p< 0.05 was considered statistically significant. At baseline, there were no differences in demographic and autonomic parameters between groups. Comparing cardiac sympatho-vagal modulation, baroreceptor sensitivity and blood pressure measurements between baseline and after 6 months, no significant difference was detected in each group or between groups. A contraceptive containing 20mcg of ethinyl estradiol and 3mg of drospirenone causes no significant changes in clinical, hemodynamic and autonomic parameters of normal women. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Kim, Kyung; Kim, Young Mi; Kang, Dong Yeon
2015-01-01
[Purpose] This study aimed to improve the asymmetrical weight-bearing ratio by applying repetitive sit-to-stand training methods that feature a step-foot position to the paretic-side foot of hemiplegic patients; it sought also to provide the information needed to apply weight-bearing and balance training to hemiplegic patients. [Subjects and Methods] The subjects were divided into two groups: a spontaneous group and a step group. They all performed repetitive sit-to-stand training five times per week for a total of six weeks. The Biodex Balance System, TUG, and 5XSST were used to measure the static and dynamic standing balance of each patient. A foot mat system was used to measure foot pressure. [Results] In the balance measurements, differences in the Overall index, Ant-post index, Med-lat index, Fall risk index, TUG, and 5XSST after training was significantly different between the two study groups. In evaluating foot pressure measurements, we found that the COP (Ant-post), Peak pressure: hind foot, and Contact area: hind foot measurements significantly differed between the groups after the training. [Conclusion] Repetitive sit-to-stand training that involves positioning the non-paretic leg upward can be considered a significant form of training that improves the symmetric posture adjustment and balance of hemiplegic patients following a stroke. PMID:26357448
Effect of high-pressure homogenization on different matrices of food supplements.
Martínez-Sánchez, Ascensión; Tarazona-Díaz, Martha Patricia; García-González, Antonio; Gómez, Perla A; Aguayo, Encarna
2016-12-01
There is a growing demand for food supplements containing high amounts of vitamins, phenolic compounds and mineral content that provide health benefits. Those functional compounds have different solubility properties, and the maintenance of their compounds and the guarantee of their homogenic properties need the application of novel technologies. The quality of different drinkable functional foods after thermal processing (0.1 MPa) or high-pressure homogenization under two different conditions (80 MPa, 33 ℃ and 120 MPa, 43 ℃) was studied. Physicochemical characteristics and sensory qualities were evaluated throughout the six months of accelerated storage at 40 ℃ and 75% relative humidity (RH). Aroma and color were better maintained in high-pressure homogenization-treated samples than the thermally treated ones, which contributed significantly to extending their shelf life. The small particle size obtained after high-pressure homogenization treatments caused differences in turbidity and viscosity with respect to heat-treated samples. The use of high-pressure homogenization, more specifically, 120 MPa, provided active ingredient homogeneity to ensure uniform content in functional food supplements. Although the effect of high-pressure homogenization can be affected by the food matrix, high-pressure homogenization can be implemented as an alternative to conventional heat treatments in a commercial setting within the functional food supplement or pharmaceutical industry. © The Author(s) 2016.
Silva-Urra, Juan A; Núñez-Espinosa, Cristian A; Niño-Mendez, Oscar A; Gaitán-Peñas, Héctor; Altavilla, Cesare; Toro-Salinas, Andrés; Torrella, Joan R; Pagès, Teresa; Javierre, Casimiro F; Behn, Claus; Viscor, Ginés
2015-12-01
The possible effects of blue light during acute hypoxia and the circadian rhythm on several physiological and cognitive parameters were studied. Fifty-seven volunteers were randomly assigned to 2 groups: nocturnal (2200-0230 hours) or diurnal (0900-1330 hours) and exposed to acute hypoxia (4000 m simulated altitude) in a hypobaric chamber. The participants were illuminated by blue LEDs or common artificial light on 2 different days. During each session, arterial oxygen saturation (Spo2), blood pressure, heart rate variability, and cognitive parameters were measured at sea level, after reaching the simulated altitude of 4000 m, and after 3 hours at this altitude. The circadian rhythm caused significant differences in blood pressure and heart rate variability. A 4% to 9% decrease in waking nocturnal Spo2 under acute hypoxia was observed. Acute hypoxia also induced a significant reduction (4%-8%) in systolic pressure, slightly more marked (up to 13%) under blue lighting. Women had significantly increased systolic (4%) and diastolic (12%) pressures under acute hypoxia at night compared with daytime pressure; this was not observed in men. Some tendencies toward better cognitive performance (d2 attention test) were seen under blue illumination, although when considered together with physiological parameters and reaction time, there was no conclusive favorable effect of blue light on cognitive fatigue suppression after 3 hours of acute hypobaric hypoxia. It remains to be seen whether longer exposure to blue light under hypobaric hypoxic conditions would induce favorable effects against fatigue. Copyright © 2015 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Resistance training controls arterial blood pressure in rats with L-NAME- induced hypertension.
Araujo, Ayslan Jorge Santos de; Santos, Anne Carolline Veríssimo dos; Souza, Karine dos Santos; Aires, Marlúcia Bastos; Santana-Filho, Valter Joviniano; Fioretto, Emerson Ticona; Mota, Marcelo Mendonça; Santos, Márcio Roberto Viana
2013-04-01
Arterial hypertension is a multifactorial chronic condition caused by either congenital or acquired factors. To evaluate the effects of Resistance Training (RT) on arterial pressure, and on vascular reactivity and morphology, of L-NAME-treated hypertensive rats. Male Wistar rats (200 - 250 g) were allocated into Sedentary Normotensive (SN), Sedentary Hypertensive (SH) and Trained Hypertensive (TH) groups. Hypertension was induced by adding L-NAME (40 mg/Kg) to the drinking water for four weeks. Arterial pressure was evaluated before and after RT. RT was performed using 50% of 1RM, 3 sets of 10 repetitions, 3 times per week for four weeks. Vascular reactivity was measured in rat mesenteric artery rings by concentration-response curves to sodium nitroprusside (SNP); phenylephrine (PHE) was also used for histological and stereological analysis. Resistance training inhibited the increase in mean and diastolic arterial pressures. Significant reduction was observed in Rmax (maximal response) and pD2 (potency) of PHE between SH and TH groups. Arteries demonstrated normal intima, media and adventitia layers in all groups. Stereological analysis demonstrated no significant difference in luminal, tunica media, and total areas of arteries in the SH and TH groups when compared to the SN group. Wall-to-lumen ratio of SH arteries was significantly different compared to SN arteries (p<0.05) but there was no difference when compared to TH arteries. RT was able to prevent an increase in blood pressure under the conditions in this study. This appears to involve a vasoconstrictor regulation mechanism and maintenance of luminal diameter in L-NAME induced hypertensive rats.
Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Moon, Hong-Kyo; Jang, Jae-Won
2013-07-01
The purpose of this study was to compare four graft-tunnel angles (GTA), the femoral GTA formed by three different femoral tunneling techniques (the outside-in, a modified inside-out technique in the posterior sag position with knee hyperflexion, and the conventional inside-out technique) and the tibia GTA in 3-dimensional (3D) knee flexion models, as well as to examine the influence of femoral tunneling techniques on the contact pressure between the intra-articular aperture of the femoral tunnel and the graft. Twelve cadaveric knees were tested. Computed tomography scans were performed at different knee flexion angles (0°, 45°, 90°, and 120°). Femoral and tibial GTAs were measured at different knee flexion angles on the 3D knee models. Using pressure sensitive films, stress on the graft of the angulation of the femoral tunnel aperture was measured in posterior cruciate ligament reconstructed cadaveric knees. Between 45° and 120° of knee flexion, there were no significant differences between the outside-in and modified inside-out techniques. However, the femoral GTA for the conventional inside-out technique was significantly less than that for the other two techniques (p<0.001). In cadaveric experiments using pressure-sensitive film, the maximum contact pressure for the modified inside-out and outside-in technique was significantly lower than that for the conventional inside-out technique (p=0.024 and p=0.017). The conventional inside-out technique results in a significantly lesser GTA and higher stress at the intra-articular aperture of the femoral tunnel than the outside-in technique. However, the results for the modified inside-out technique are similar to those for the outside-in technique.
Articular contact pressures of meniscal repair techniques at various knee flexion angles.
Flanigan, David C; Lin, Fang; Koh, Jason L; Zhang, Li-Qun
2010-07-13
Articular cartilage injury can occur after meniscal repair with biodegradable implants. Previous contact pressure analyses of the knee have been based on the tibial side of the meniscus at limited knee flexion angles. We investigated articular contact pressures on the posterior femoral condyle with different knee flexion angles and surgical repair techniques. Medial meniscus tears were repaired in 30 fresh bovine knees. Knees were mounted on a 6-degrees-of-freedom jig and statically loaded to 200 N at 45 degrees, 70 degrees, 90 degrees, and 110 degrees of knee flexion under 3 conditions: intact meniscus, torn meniscus, and meniscus after repair. For each repair, 3 sutures or biodegradable implants were used. A pressure sensor was used to determine the contact area and peak pressure. Peak pressures over each implant position were measured. Peak pressure increased significantly as knee flexion increased in normal, injured, and repaired knees. The change in peak pressure in knees with implant repairs was significantly higher than suture repairs at all knee flexion angles. Articular contact pressure on the posterior femoral condyle increased with knee flexion. Avoidance of deep knee flexion angles postoperatively may limit increases in articular contact pressures and potential chondral injury. Copyright 2010, SLACK Incorporated.
Micalos, Peter S; Korgaonkar, Mayuresh S; Drinkwater, Eric J; Cannon, Jack; Marino, Frank E
2014-01-01
Objective The purpose of this research was to assess the functional brain activity and perceptual rating of innocuous somatic pressure stimulation before and after exercise rehabilitation in patients with chronic pain. Materials and methods Eleven chronic pain patients and eight healthy pain-free controls completed 12 weeks of supervised aerobic exercise intervention. Perceptual rating of standardized somatic pressure stimulation (2 kg) on the right anterior mid-thigh and brain responses during functional magnetic resonance imaging (fMRI) were assessed at pre- and postexercise rehabilitation. Results There was a significant difference in the perceptual rating of innocuous somatic pressure stimulation between the chronic pain and control groups (P=0.02) but no difference following exercise rehabilitation. Whole brain voxel-wise analysis with correction for multiple comparisons revealed trends for differences in fMRI responses between the chronic pain and control groups in the superior temporal gyrus (chronic pain > control, corrected P=0.30), thalamus, and caudate (control > chronic, corrected P=0.23). Repeated measures of the regions of interest (5 mm radius) for blood oxygen level-dependent signal response revealed trend differences for superior temporal gyrus (P=0.06), thalamus (P=0.04), and caudate (P=0.21). Group-by-time interactions revealed trend differences in the caudate (P=0.10) and superior temporal gyrus (P=0.29). Conclusion Augmented perceptual and brain responses to innocuous somatic pressure stimulation were shown in the chronic pain group compared to the control group; however, 12-weeks of exercise rehabilitation did not significantly attenuate these responses. PMID:25210471
Blood pressure variability of two ambulatory blood pressure monitors.
Kallem, Radhakrishna R; Meyers, Kevin E C; Cucchiara, Andrew J; Sawinski, Deirdre L; Townsend, Raymond R
2014-04-01
There are no data on the evaluation of blood pressure (BP) variability comparing two ambulatory blood pressure monitoring monitors worn at the same time. Hence, this study was carried out to compare variability of BP in healthy untreated adults using two ambulatory BP monitors worn at the same time over an 8-h period. An Accutorr device was used to measure office BP in the dominant and nondominant arms of 24 participants.Simultaneous 8-h BP and heart rate data were measured in 24 untreated adult volunteers by Mobil-O-Graph (worn for an additional 16 h after removing the Spacelabs monitor) and Spacelabs with both random (N=12) and nonrandom (N=12) assignment of each device to the dominant arm. Average real variability (ARV), SD, coefficient of variation, and variation independent of mean were calculated for systolic blood pressure, diastolic blood pressure, mean arterial pressure, and pulse pressure (PP). Whether the Mobil-O-Graph was applied to the dominant or the nondominant arm, the ARV of mean systolic (P=0.003 nonrandomized; P=0.010 randomized) and PP (P=0.009 nonrandomized; P=0.005 randomized) remained significantly higher than the Spacelabs device, whereas the ARV of the mean arterial pressure was not significantly different. The average BP readings and ARVs for systolic blood pressure and PP obtained by the Mobil-O-Graph were considerably higher for the daytime than the night-time. Given the emerging interest in the effect of BP variability on health outcomes, the accuracy of its measurement is important. Our study raises concerns about the accuracy of pooling international ambulatory blood pressure monitoring variability data using different devices.
Increasing preferred step rate during running reduces plantar pressures.
Gerrard, James M; Bonanno, Daniel R
2018-01-01
Increasing preferred step rate during running is a commonly used strategy in the management of running-related injuries. This study investigated the effect of different step rates on plantar pressures during running. Thirty-two healthy runners ran at a comfortable speed on a treadmill at five step rates (preferred, ±5%, and ±10%). For each step rate, plantar pressure data were collected using the pedar-X in-shoe system. Compared to running with a preferred step rate, a 10% increase in step rate significantly reduced peak pressure (144.5±46.5 vs 129.3±51 kPa; P=.033) and maximum force (382.3±157.6 vs 334.0±159.8 N; P=.021) at the rearfoot, and reduced maximum force (426.4±130.4 vs 400.0±116.6 N; P=.001) at the midfoot. In contrast, a 10% decrease in step rate significantly increased peak pressure (144.5±46.5 vs 161.5±49.3 kPa; P=.011) and maximum force (382.3±157.6 vs 425.4±155.3 N; P=.032) at the rearfoot. Changing step rate by 5% provided no effect on plantar pressures, and no differences in plantar pressures were observed at the medial forefoot, lateral forefoot or hallux between the step rates. This study's findings indicate that increasing preferred step rate by 10% during running will reduce plantar pressures at the rearfoot and midfoot, while decreasing step rate by 10% will increase plantar pressures at the rearfoot. However, changing preferred step rate by 5% will provide no effect on plantar pressures, and forefoot pressures are unaffected by changes in step rate. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Size at birth and blood pressure: cross sectional study in 8-11 year old children.
Taylor, S. J.; Whincup, P. H.; Cook, D. G.; Papacosta, O.; Walker, M.
1997-01-01
OBJECTIVE: To identify which patterns of fetal growth, represented by different measurements of size at birth, are associated with increased blood pressure in children aged 8-11 years. DESIGN AND SETTING: School based, cross sectional survey conducted in 10 towns in England and Wales in 1994. SUBJECTS: 3010 singleton children (response rate 75%) with physical measurements and information on birth weight from parental questionnaires. Hospital birth records were examined for 1573. MAIN OUTCOME MEASURES: Systolic and diastolic blood pressure at age 8-11 years. RESULTS: In the whole group birth weight was inversely related to systolic pressure (regression coefficient -1.48 mm Hg/kg; 95% confidence interval -2.20 to -0.76) after adjustment for current body size. There was no significant association between birth weight and diastolic pressure. The association with systolic pressure was much stronger in girls (-2.54 mm Hg/kg; -3.60 to -1.48) than in boys (-0.64 mm Hg/kg; -1.58 to 0.30), with a significant difference between the sexes (P = 0.006). Among the other neonatal measures, head circumference and placental weight were inversely associated with subsequent blood pressure in girls, and placental ratio (placental weight:birth weight) was positively associated with blood pressure in boys. Neither ponderal index at birth nor length:head circumference ratio was related to blood pressure in either sex. CONCLUSIONS: In these contemporary children the association between birth weight and blood pressure was apparent only in girls. There was no evidence that measures of size at birth, which may be related to nutrition at critical periods of pregnancy (thinness at birth or shortness in relation to head circumference), are related to blood pressure in the offspring. PMID:9056797
Defontaine, Anne; Tirel, Olivier; Costet, Nathalie; Beuchée, Alain; Ozanne, Bruno; Gaillot, Théophile; Arnaud, Alexis Pierre; Wodey, Eric
2016-02-01
To determine the optimal saline volume bladder instillation to measure intravesical pressure in critically ill newborns weighing less than 4.5 kg, and to establish a reference of intra-abdominal pressure value in this population. Prospective monocentric study. Neonatal ICU and PICU. Newborns, premature or not, weighing less than 4.5 kg who required a urethral catheter. Patients were classified into two groups according to whether they presented a risk factor for intra-abdominal hypertension. Nine intravesical pressure measures per patient were performed after different volume saline instillation. The first one was done without saline instillation and then by increments of 0.5 mL/kg to a maximum of 4 mL/kg. Linear models for repeated measurements of intravesical pressure with unstructured covariance were used to analyze the variation of intravesical pressure measures according to the conditions of measurement (volume instilled). Pairwise comparisons of intravesical pressure adjusted mean values between instillation volumes were done using Tukey tests, corrected for multiple testing to determine an optimal instillation volume. Forty-seven patients with completed measures (nine instillations volumes) were included in the analysis. Mean intravesical pressure values were not significantly different when measured after instillation of 0.5, 1, or 1.5 mL/kg, whereas measures after instillation of 2 mL/kg or more were significantly higher. The median intravesical pressure value in the group without intra-abdominal hypertension risk factor after instillation of 1 mL/kg was 5 mm Hg (2-6 mm Hg). The optimal saline volume bladder instillation to measure intra-abdominal pressure in newborns weighing less than 4.5 kg was 1 mL/kg. Reference intra-abdominal pressure in this population was found to be 5 mm Hg (2-6 mm Hg).
Zeng, Rui; Wang, Mian; Zhang, Li
2016-07-26
BACKGROUND Is the timing of dosing for amlodipine and atorvastatin important with regard to therapeutic efficacy? To answer this question, we designed an outpatient, practice-based, case-control study lasting 8 weeks. MATERIAL AND METHODS Two hundred patients were divided into 2 groups: in Group I, patients were provided with a single pill containing amlodipine/atorvastatin (5/20 mg) to be taken each night at 10 pm, and in Group II, patients were taking amlodipine (5 mg) and atorvastatin (20 mg) each morning at 7 am. RESULTS Our results indicated no obvious difference in blood pressure control between the 2 groups. Taking amlodipine at night not only lowered blood pressure, but it also provided better control during the peak blood pressure in the morning. Hypercholesterolemia control in the 2 groups was also not significantly different, taking atorvastatin in the morning was as effective as dosing at night in patients with hypercholesterolemia. While the carotid IMT, hs-CRP, and LVMI were significantly lower after treatment, no differences were found between the 2 groups. Although no obvious difference was found in adverse drug reactions between the 2 groups, compliance was much better in the single-pill group than in patients taking the 2 medications separately. CONCLUSIONS In conclusion, single-pill amlodipine-atorvastatin taken at night can lower blood pressure and reduce the morning peak blood pressure levels the next day. Additionally, this dosing method could improve patient adherence to the therapy.
The effects of prenatal and postnatal (via nursing) exposure to alcohol in rats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nekvasil, N.; Baggio, C.
Pregnant and post-partum rats were given daily doses of 20% alcohol during days 13-21 gestation and postnatal days 3-12, respectively. Following exposure, all rat pups, were tested for balance, blood pressure, right and left cerebral hemisphere weights, and cerebellar weight. Results were grouped according to exposure and gender. The postnatal group was the only one to demonstrate difficulties with balance. The mean arterial pressure in males exposed postnatally was significantly lower than the control and prenatal males. Females exposed postnatally had a significantly higher blood pressure than control females. Within the postnatal group, males had a significantly lower blood pressuremore » than the females. Prenatal and control females differed significantly for left cerebral hemisphere (LCH) weight with the prenatal weighing less. Male pups exposed prenatally had significantly heavier LCH than the postnatal and control males. For both males and females, postnatal LCH weights did not differ from those of the control pups. Within the prenatal group, the LCH weight in females was significantly lower than in males. Mean cerebellar weights were significantly lower in postnatal animals compared to control animals. A major finding of this study is that the effect of alcohol exposure on rat pups depends on gender and developmental age.« less
Park, Ji Soon; McGarry, Michelle H; Campbell, Sean T; Seo, Hyuk Jun; Lee, Yeon Soo; Kim, Sae Hoon; Lee, Thay Q; Oh, Joo Han
2015-09-01
Transosseous-equivalent (TOE) rotator cuff repair can increase contact area and contact pressure between the repaired cuff tendon and bony footprint and can show higher ultimate loads to failure and smaller gap formation compared with other repair techniques. However, it has been suggested that medial rotator cuff failure after TOE repair may result from increased bridging suture tension. To determine optimum bridging suture tension in TOE repair by evaluating footprint contact and construct failure characteristics at different tensions. Controlled laboratory study. A total of 18 fresh-frozen cadaveric shoulders, randomly divided into 3 groups, were constructed with a TOE configuration using the same medial suture anchor and placing a Tekscan sensing pad between the repaired rotator cuff tendon and footprint. Nine of the 18 shoulders were used to measure footprint contact characteristics. With use of the Tekscan measurement system, the contact pressure and area between the rotator cuff tendon and greater tuberosity were quantified for bridging suture tensions of 60, 90, and 120 N with glenohumeral abduction angles of 0° and 30° and humeral rotation angles of 30° (internal), 0°, and 30° (external). TOE constructs of all 18 shoulders then underwent construct failure testing (cyclic loading and load to failure) to determine the yield load, ultimate load, stiffness, hysteresis, strain, and failure mode at 60 and 120 N of tension. As bridging suture tension increased, contact force, contact pressure, and peak pressure increased significantly at all positions (P < .05 for all). Regarding contact area, no significant differences were found between 90 and 120 N at all positions, although there were significant differences between 60 and 90 N. The construct failure test demonstrated no significant differences in any parameters according to various tensions (P > .05 for all). Increasing bridging suture tension to over 90 N did not improve contact area but did increase contact force and pressure. Bridging suture tension did not significantly affect ultimate failure loads. Considering the risks of overtensioning bridging sutures, it may be clinically more beneficial to keep bridging suture tension below 90 N. © 2015 The Author(s).
Fujita, Masashi; Onami, Shuichi
2012-01-01
In the two-cell stage embryos of Caenorhabditis elegans, the contact surface of the two blastomeres forms a curve that bulges from the AB blastomere to the P1 blastomere. This curve is a consequence of the high intracellular hydrostatic pressure of AB compared with that of P1. However, the higher pressure in AB is intriguing because AB has a larger volume than P1. In soap bubbles, which are a widely used model of cell shape, a larger bubble has lower pressure than a smaller bubble. Here, we reveal that the higher pressure in AB is mediated by its higher cortical tension. The cell fusion experiments confirmed that the curvature of the contact surface is related to the pressure difference between the cells. Chemical and genetic interferences showed that the pressure difference is mediated by actomyosin. Fluorescence imaging indicated that non-muscle myosin is enriched in the AB cortex. The cell killing experiments provided evidence that AB but not P1 is responsible for the pressure difference. Computer simulation clarified that the cell-to-cell heterogeneity of cortical tensions is indispensable for explaining the pressure difference. This study demonstrates that heterogeneity in surface tension results in significant deviations of cell behavior compared to simple soap bubble models, and thus must be taken into consideration in understanding cell shape within embryos. PMID:22253922
Ozyurek, Pakize; Yavuz, Meryem
2015-01-01
The aim of this study is to compare whether differences exist between 2 viscoelastic foam support surfaces in the development of new pressure ulcers. There is evidence to support the use of viscoelastic foam over standard hospital foam to reduce pressure. A comparative effectiveness study was done to compare 2 viscoelastic foam support surfaces. A randomized controlled trial was carried out. The study was performed in 2 intensive care units between October 1, 2008, and January 4, 2010. Patients (n = 105) admitted to intensive care unit were randomly assigned to viscoelastic foam 1 (n = 53) or viscoelastic foam 2 support surface (n = 52). In total, 42.8% of all patients developed a new pressure ulcer of stage 1 or worse. By stages, pressure ulcer incidence was 28.6%, 13.3%, and 1.0% for stages 1, 2, and 3, respectively. There was no significant difference in pressure ulcer incidence between the viscoelastic foam 1 and 2 groups (X2 = 0.07, df = 1, P > .05). No difference was found between 2 different viscoelastic foam surfaces in the prevention of pressure ulcers in patients treated in intensive care. Pressure ulcer incidence in critically ill patients remains high. Nurses must compare current products for effectiveness and develop innovative systems, processes, or devices to deliver best practices.
Karrasch, Nicole M; Hubbell, John A E; Aarnes, Turi K; Bednarski, Richard M; Lerche, Phillip
2015-04-01
This study compared cardiorespiratory variables in dorsally recumbent horses anesthetized with guaifenesin-ketamine-xylazine and spontaneously breathing 50% or maximal (> 90%) oxygen (O2) concentrations. Twelve healthy mares were randomly assigned to breathe 50% or maximal O2 concentrations. Horses were sedated with xylazine, induced to recumbency with ketamine-diazepam, and anesthesia was maintained with guaifenesin-ketamine-xylazine to effect. Heart rate, arterial blood pressures, respiratory rate, lithium dilution cardiac output (CO), inspired and expired O2 and carbon dioxide partial pressures, and tidal volume were measured. Arterial and mixed-venous blood samples were collected prior to sedation (baseline), during 30 minutes of anesthesia, 10 minutes after disconnection from O2, and 30 minutes after standing. Shunt fraction, O2 delivery, and alveolar-arterial O2 partial pressures difference [P(A-a)O2] were calculated. Recovery times were recorded. There were no significant differences between groups in cardiorespiratory parameters or in P(A-a)O2 at baseline or 30 minutes after standing. Oxygen partial pressure difference in the 50% group was significantly less than in the maximal O2 group during anesthesia.
Karrasch, Nicole M.; Hubbell, John A.E.; Aarnes, Turi K.; Bednarski, Richard M.; Lerche, Phillip
2015-01-01
This study compared cardiorespiratory variables in dorsally recumbent horses anesthetized with guaifenesin-ketamine-xylazine and spontaneously breathing 50% or maximal (> 90%) oxygen (O2) concentrations. Twelve healthy mares were randomly assigned to breathe 50% or maximal O2 concentrations. Horses were sedated with xylazine, induced to recumbency with ketamine-diazepam, and anesthesia was maintained with guaifenesin-ketamine-xylazine to effect. Heart rate, arterial blood pressures, respiratory rate, lithium dilution cardiac output (CO), inspired and expired O2 and carbon dioxide partial pressures, and tidal volume were measured. Arterial and mixed-venous blood samples were collected prior to sedation (baseline), during 30 minutes of anesthesia, 10 minutes after disconnection from O2, and 30 minutes after standing. Shunt fraction, O2 delivery, and alveolar-arterial O2 partial pressures difference [P(A-a)O2] were calculated. Recovery times were recorded. There were no significant differences between groups in cardiorespiratory parameters or in P(A-a)O2 at baseline or 30 minutes after standing. Oxygen partial pressure difference in the 50% group was significantly less than in the maximal O2 group during anesthesia. PMID:25829559
Bakris, George; Burgess, Ellen; Weir, Matthew; Davidai, Giora; Koval, Stephen
2008-08-01
In patients with diabetic nephropathy, lowering blood pressure and reducing proteinuria by over 30% correlates with a slower progression to kidney failure. We compared two different angiotensin receptor-blockers in a double blind, prospective trial of 860 patients with type 2 diabetes whose blood pressure levels was over 130/80 mmHg or who were receiving antihypertensive medication(s) and who had a morning spot urinary protein to creatinine ratio of 700 or more. Patients were randomized to telmisartan (a highly lipophilic agent with a long half-life) or losartan (with low lipophilicity and short half-life). The primary endpoint was the difference in the urinary albumin to creatinine ratio between the groups at 52 weeks. The geometric coefficient of variation and the mean of the urinary albumin to creatinine ratio fell in both groups at 52 weeks but both were significantly greater for the telmisartan compared to the losartan cohort. Mean systolic blood pressure reductions were not significantly different between groups at trial end. We conclude that telmisartan is superior to losartan in reducing proteinuria in hypertensive patients with diabetic nephropathy, despite a similar reduction in blood pressure.
Jamner, L D; Shapiro, D; Goldstein, I B; Hug, R
1991-01-01
Ambulatory blood pressure and heart rate responses were obtained in 33 male paramedics during a 24-hour work shift to examine the effects of episodes of occupational stress on cardiovascular reactivity and subjective reports of stress. The aim of this study was to determine how individual differences in cynical hostility and defensiveness interacted with situational demands to affect cardiovascular responses in a natural setting. Defensiveness was found to interact significantly with cynical hostility in predicting subjects' heart rate responses in different work contexts. Specifically, in a hospital setting involving interpersonal conflict, subjects who were high in both defensiveness and hostility showed heart rate responses approximately 10 bpm higher than subjects who were high in hostility but low in defensiveness. The same pattern of relationships was obtained for diastolic blood pressure. High and low hostile subjects were also found to differ from each other in their daily mean levels of ambulatory blood pressure during awake and sleep periods. These findings obtained in a natural setting lend further support to the significance of cynical hostility for cardiovascular reactivity. The results for defensiveness suggest the need for further research on the role of conflicting attitudes in the pathophysiology of cardiovascular diseases.
Schick, Erik; Bertrand, Pierre E; Jolivet-Tremblay, Martine; Dupont, Charles; Tessier, Jocelyne
2004-01-01
To study the relation between maximum urethral closure pressure (MUCP) at rest and the degree of urethral incompetence in the female. Two hundred fifty five patients aged 20 years or older, with stable bladders on multichannel urodynamics, without known neurological pathology, and with no previous history of pelvic or anti-incontinence surgery were included in the study. Resting urethral pressure profile (UPP) and the grade of urethral incompetence was registered. Mean age of the group was 45.6+/-12.7 years; mean MUCP was 62.7+/-28.5 cm of water. There was a statistically significant difference in the MUCP when the different grades of urethral incompetence were compared to each other, the higher grades being associated with a lower maximal closure pressure. This study demonstrates that there is a highly significant relationship between MUCP and between all grades of urethral incompetence. This supports previous observations that MUCP decreases when abdominal leak point pressure (ALPP) is low and that this might be secondary to some mechanical failure in the pressure transmission from the abdominal cavity to the urethra. Studies should never compare continent to incontinent cohorts without considering their ALPP because in doing so they are comparing groups that are functionally heterogeneous. Copyright 2003 Wiley-Liss, Inc.
González-Camarena, Pedro Iván; San-Juan, Daniel; González-Olhovich, Irene; Rodríguez-Arévalo, David; Lozano-Elizondo, David; Trenado, Carlos; Anschel, David J
2017-03-01
To describe the dynamic changes of the intraocular pressure (IOP) and intracranial pressure (ICP) with normal or pathological values (intracranial hypertension) in nonglaucomatous neurological patients during lumbar punction (LP). Case-control study, prospective measurement of tonometry in both groups referred for LP. Intraocular pressure, ICP and translaminar pressure difference (TPD) were compared pre- and post-LP. Thirty-six patients (72 eyes) with mean age of 38.5 (16-64) years and BMI of 26.81 kg/m 2 were analysed. The initial mean ICP was 12.81 (± 6.6) mmHg. The mean TPD before and after the LP was 1.48 mmHg and 0.65 mmHg, respectively. The mean IOP of both eyes decreased to 0.8 mmHg post-LP in patients with pathological ICP (p = 0.0193) and normal ICP (p = 0.006). We found a statistically significant decrease of the IOP post-LP compared to the pre-LP in both groups, being higher in patients with pathological ICP. There were no significant differences of the IOP in patients with normal versus pathological ICP pre-LP/post-LP; neither was found a correlation between ICP and IOP. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Niu, Xiaoguang; Song, Xubin; Su, Aiping; Zhao, Shanshan; Li, Qinghao
2017-04-01
We aimed to evaluate the effect of different capnoperitoneum pressures on stress responses in pediatric laparoscopic inguinal hernia repair. In this prospective randomized controlled study, 68 children with indirect inguinal hernia who underwent high ligation of hernia sac were randomly divided into 3 groups: high-pressure group (12 mm Hg, HP group, n = 26); low-pressure group (8 mm Hg, LP group, n = 20); open operation group (OP group, n = 22). Heart rate (HR), blood pressure, and end-tidal CO2 (PetCO2) were recorded, as well as the levels of adrenocorticotropic hormone (ACTH) and cortisol (COR) were measured by ELISAs before operation, during operation, and after operation, respectively. After establishing capnoperitoneum, HR, blood pressure, and PetCO2 were significantly increased in the HP group compared with the OP and LP groups (P < 0.05). Comparing the intraoperatively measured ACTH and COR concentrations of the HP group to the LP group, we noted higher values in the first (P < 0.05). There was no significant difference in the postoperative concentrations of ACTH and COR among the HP, LP, and OP groups. Laparoscopic surgery under LP capnoperitoneum or open operation may reduce stress responses and are superior to HP capnoperitoneum.
Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander
2018-04-01
Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Cheng, Mei; Cheng, Shu-Ling; Zhang, Qing; Jiang, He; Cong, Ji-Yan; Zang, Xiao-Ying; Zhao, Yue
2014-08-01
To explore the effect of continuous nursing intervention guided by chronotherapeutics so as to provide the easy, noninvasive, effective and acceptable intervention for older hypertensive patients in the community. Many researchers studied the effect of administration at different times on blood pressure control and circadian rhythm. However, the individual administrative time was set ambiguously in previous studies. A semi-experimental study. In the study, 90 eligible patients were recruited and separated into three groups randomly, which were the control group, intervention group A (behaviour and chronotherapy intervention) and intervention group B (behaviour intervention). At 6 and 12 months after the study, the intervention groups were measured 24-hour ambulatory blood pressure monitoring. There were significant differences in ambulatory blood pressure monitoring parameters of the two intervention groups at different measurement times, and there were interaction between measurement time and different groups. The number of patients with dipper increased and reverse dipper decreased in group A as the intervention applied. There were statistical differences between two groups. The number of patients with morning surge in group A decreased more, and there were statistical differences between two groups at six months after the intervention. The behaviour and chronotherapy intervention based on the patients' ambulatory blood pressure monitoring can control casual blood pressure much better and last longer, which can also improve patients' indexes of ambulatory blood pressure monitoring better than behaviour intervention only. The behaviour and chronotherapy intervention can increase patients' nocturnal blood pressure drop, increase the number of patients with dipper and decrease reverse dipper, and improve blood pressure surge in the morning. Nurses can use continuous nursing intervention guided by chronotherapeutics to help improve hypertension of older patients better in the community. © 2014 John Wiley & Sons Ltd.
Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang
2005-01-01
To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.
Lang, Erhard W; Kasprowicz, Magdalena; Smielewski, Peter; Pickard, John; Czosnyka, Marek
2015-08-01
Plateau waves in intracranial pressure (ICP) are frequently recorded in neuro intensive care and are not yet fully understood. To further investigate this phenomenon, we analyzed partial pressure of cerebral oxygen (pbtO2) and a moving correlation coefficient between ICP and mean arterial blood pressure (ABP), called PRx, along with the cerebral oxygen reactivity index (ORx), which is a moving correlation coefficient between cerebral perfusion pressure (CPP) and pbtO2 in an observational study. We analyzed 55 plateau waves in 20 patients after severe traumatic brain injury. We calculated ABP, ABP pulse amplitude (ampABP), ICP, CPP, pbtO2, heart rate (HR), ICP pulse amplitude (ampICP), PRx, and ORx, before, during, and after each plateau wave. The analysis of variance with Bonferroni post hoc test was used to compare the differences in the variables before, during, and after the plateau wave. We considered all plateau waves, even in the same patient, independent because they are separated by long intervals. We found increases for ICP and ampICP according to our operational definitions for plateau waves. PRx increased significantly (p = 0.00026), CPP (p < 0.00001) and pbtO2 (p = 0.00007) decreased significantly during the plateau waves. ABP, ampABP, and HR remained unchanged. PRx during the plateau was higher than before the onset of wave in 40 cases (73 %) with no differences in baseline parameters for those with negative and positive ΔPRx (difference during and after). ORx showed an increase during and a decrease after the plateau waves, however, not statistically significant. PbtO2 overshoot after the wave occurred in 35 times (64 %), the mean difference was 4.9 ± 4.6 Hg (mean ± SD), and we found no difference in baseline parameters between those who overshoot and those who did not overshoot. Arterial blood pressure remains stable in ICP plateau waves, while cerebral autoregulatory indices show distinct changes, which indicate cerebrovascular reactivity impairment at the top of the wave. PbtO2 decreases during the waves and may show a slight overshoot after normalization. We assume that this might be due to different latencies of the cerebral blood flow and oxygen level control mechanisms. Other factors may include baseline conditions, such as pre-plateau wave cerebrovascular reactivity or pbtO2 levels, which differ between studies.
The development of pressure across membranes in Donnan systems
Ilani, Asher
2015-01-01
The pressure that develops between the two sides of a Donnan system is equal to the difference between the osmotic values of the two solutions, even though permeant ions may constitute a significant part of that difference. This is amply documented for the case of membranes that allow water movement through them by single molecules diffusing in isolation or in series through specific proteins (such as aquaporins). In this article, the development of pressure was analysed for a system in which membranes contain a few bulk aqueous pores that prevent charged polymers from entering them due to their size. It is shown analytically that the pressure that develops by the action of the electric field on the net charges in the pores is equal to the difference in the osmotic values of the solutions contributed by the permeant ions. Thus, the sum of the pressures that develop in the system due to the action of the electric field in the pores (a pushing force) and the concentration of the impermeant polymers at the interface (a sucking force), accounts for the total colloid osmotic pressure in these systems. PMID:26456154
Ge, Ying; Wan, Yong; Wang, Da-qing; Su, Xiao-lin; Li, Jun-ying; Chen, Jing
2004-07-01
To investigate the significance and effect of pressure controlled ventilation (PCV) as well as volume controlled ventilation (VCV) by lung protective strategy on respiratory mechanics, blood gas analysis and hemodynamics in patients with acute respiratory distress syndrome (ARDS). Fifty patients with ARDS were randomly divided into PCV and VCV groups with permissive hypercapnia and open lung strategy. Changes in respiratory mechanics, blood gas analysis and hemodynamics were compared between two groups. Peak inspiration pressure (PIP) in PCV group was significantly lower than that in VCV group, while mean pressure of airway (MPaw) was significantly higher than that in VCV after 24 hours mechanical ventilation. After 24 hours mechanical ventilation, there were higher central venous pressure (CVP) and slower heart rate (HR) in two groups, CVP was significantly higher in VCV compared with PCV, and PCV group had slower HR than VCV group, the two groups had no differences in mean blood pressure (MBP) at various intervals. All patients showed no ventilator-induced lung injury. Arterial blood oxygenations were obviously improved in two groups after 24 hours mechanical ventilation, PCV group had better partial pressure of oxygen in artery (PaO2) than VCV group. Both PCV and VCV can improve arterial blood oxygenations, prevent ventilator-induced lung injury, and have less disturbance in hemodynamic parameters. PCV with lung protective ventilatory strategy should be early use for patients with ARDS.
2016-01-01
We evaluated the individual and combined effects of salinity and alkalinity on gill Na+/K+-ATPase enzyme activity, plasma ion concentration, and osmotic pressure in Luciobarbus capito. Increasing salinity concentrations (5, 8, 11, and 14 g/L) were associated with an initial increase and then decrease in L. capito gill Na+/K+-ATPase activity. Activity was affected by the difference between internal and external Na+ ion concentrations and osmotic pressure (P < 0.05). Both plasma ion (Na+, K+, and Cl−) concentration and osmotic pressure increased significantly (P < 0.05). An increase in alkalinity (15, 30, 45, and 60 mM) caused a significant increase in plasma K+ and urea nitrogen concentrations (P < 0.05) but had no effect on either plasma osmotic pressure or gill filament ATPase activity. In the two-factor experiment, the saline-alkaline interaction caused a significant increase in plasma ion (Na+, Cl−, and urea nitrogen) and osmotic pressure (P < 0.05). Variance analysis revealed that salinity, alkalinity, and their interaction significantly affected osmotic pressure, with salinity being most affected, followed by alkalinity, and their interaction. Gill filament ATPase activity increased at first and then decreased; peak values were observed in the orthogonal experiment group at a salinity of 8 g/L and alkalinity of 30 mM. PMID:27981049
Genome-wide association study in Chinese identifies novel loci for blood pressure and hypertension
Lu, Xiangfeng; Wang, Laiyuan; Lin, Xu; Huang, Jianfeng; Charles Gu, C.; He, Meian; Shen, Hongbing; He, Jiang; Zhu, Jingwen; Li, Huaixing; Hixson, James E.; Wu, Tangchun; Dai, Juncheng; Lu, Ling; Shen, Chong; Chen, Shufeng; He, Lin; Mo, Zengnan; Hao, Yongchen; Mo, Xingbo; Yang, Xueli; Li, Jianxin; Cao, Jie; Chen, Jichun; Fan, Zhongjie; Li, Ying; Zhao, Liancheng; Li, Hongfan; Lu, Fanghong; Yao, Cailiang; Yu, Lin; Xu, Lihua; Mu, Jianjun; Wu, Xianping; Deng, Ying; Hu, Dongsheng; Zhang, Weidong; Ji, Xu; Guo, Dongshuang; Guo, Zhirong; Zhou, Zhengyuan; Yang, Zili; Wang, Renping; Yang, Jun; Zhou, Xiaoyang; Yan, Weili; Sun, Ningling; Gao, Pingjin; Gu, Dongfeng
2015-01-01
Hypertension is a common disorder and the leading risk factor for cardiovascular disease and premature deaths worldwide. Genome-wide association studies (GWASs) in the European population have identified multiple chromosomal regions associated with blood pressure, and the identified loci altogether explain only a small fraction of the variance for blood pressure. The differences in environmental exposures and genetic background between Chinese and European populations might suggest potential different pathways of blood pressure regulation. To identify novel genetic variants affecting blood pressure variation, we conducted a meta-analysis of GWASs of blood pressure and hypertension in 11 816 subjects followed by replication studies including 69 146 additional individuals. We identified genome-wide significant (P < 5.0 × 10−8) associations with blood pressure, which included variants at three new loci (CACNA1D, CYP21A2, and MED13L) and a newly discovered variant near SLC4A7. We also replicated 14 previously reported loci, 8 (CASZ1, MOV10, FGF5, CYP17A1, SOX6, ATP2B1, ALDH2, and JAG1) at genome-wide significance, and 6 (FIGN, ULK4, GUCY1A3, HFE, TBX3-TBX5, and TBX3) at a suggestive level of P = 1.81 × 10−3 to 5.16 × 10−8. These findings provide new mechanistic insights into the regulation of blood pressure and potential targets for treatments. PMID:25249183
Takeda, R; Matsubara, T; Miyamori, I; Hatakeyama, H; Morise, T
1995-05-01
The incidence of vascular complications in 224 patients with aldosterone-producing adenoma (APA) which was proven on adrenal surgery, was compared to that in 224 sex- and age-matched patients with essential hypertension (EHT). The incidence of cerebral hemorrhage was significantly higher (p < 0.05) in the patients with APA when compared to the EHT group. On the other hand, the incidence of myocardial infarction and/or congestive heart failure in the APA group was lower, although this difference did not reach statistical significance. Diastolic blood pressure in the APA group was significantly higher (p < 0.001) in the EHT group. However, a significant difference in diastolic blood pressure was not detected between the APA groups with and without vascular complications, whereas in the EHT group diastolic blood pressure was significantly higher (p < 0.001) in cases with vascular complications as compared to those without complications. As a possible factor contributing to the higher incidence of cerebral hemorrhage in the APA group, proteinuria was suggested. It was recommended that patients with primary aldosteronism should undergo operation when localization of the APA is established.
Effect of hydrostatic pressure on regional bond strengths of compomers to dentine.
Zheng, L; Pereira, P N; Somphone, P; Nikaido, T; Tagami, J
2000-09-01
The aim of this study was to evaluate the effect of hydrostatic pressure on the regional bond strengths of compomers to dentine. Thirty freshly extracted molars were ground flat to expose the dentine and randomly divided into two groups for bonding: no hydrostatic pressure and hydrostatic pressure of 15cm H(2)O. Xeno CF, Dyract AP and F 2000 were applied to dentine surfaces pretreated by the respective bonding systems following the manufactures' instructions, and then restored with Clearfil AP-X. After 24h storage in water, the teeth were sectioned into 0.7-mm thick slabs and visually divided into three regional subgroups: the region communicating with the pulp through dentinal tubules (pulp horn); the region between the pulp horns (center); and the region between the pulp horn and DEJ (periphery). The specimens were trimmed to a cross-sectional area of 1mm(2) and subjected to the micro-tensile bond test. The data were analyzed by one- and three-way ANOVA, and Fisher's PLSD (p<0.05). There were no significant regional differences of bond strengths for all the compomers tested (p>0.05). However, hydrostatic pressure significantly decreased the bond strength of F 2000 to all regions (p<0.05), while the bond strength of Dyract AP significantly decreased only at the pulp horn region (p<0.05). On the other hand, the bond strengths of Xeno CF seemed not to be affected by hydrostatic pressure (p>0.05). For Dyract AP and F 2000, the fracture modes were affected by hydrostatic pressure, while, for Xeno CF, there were no significant differences between the fracture modes with non- or positive hydrostatic pressure. Simulated pulpal pressure of 15cm H(2)O had a greater influence on the bond strengths of compomers to dentine than did dentine regions. Therefore, when measuring the bond strengths of compomers to dentine under the simulated in vivo conditions, the wetness of the dentine surface, as well as the intrinsic properties of each material should be seriously considered.
The Effects of Compression-Garment Pressure on Recovery After Strenuous Exercise.
Hill, Jessica; Howatson, Glyn; van Someren, Ken; Gaze, David; Legg, Hayley; Lineham, Jack; Pedlar, Charles
2017-09-01
Compression garments are frequently used to facilitate recovery from strenuous exercise. To identify the effects of 2 different grades of compression garment on recovery indices after strenuous exercise. Forty-five recreationally active participants (n = 26 male and n = 19 female) completed an eccentric-exercise protocol consisting of 100 drop jumps, after which they were matched for body mass and randomly but equally assigned to a high-compression pressure (HI) group, a low-compression pressure (LOW) group, or a sham ultrasound group (SHAM). Participants in the HI and LOW groups wore the garments for 72 h postexercise; participants in the SHAM group received a single treatment of 10-min sham ultrasound. Measures of perceived muscle soreness, maximal voluntary contraction (MVC), countermovement-jump height (CMJ), creatine kinase (CK), C-reactive protein (CRP), and myoglobin (Mb) were assessed before the exercise protocol and again at 1, 24, 48, and 72 h postexercise. Data were analyzed using a repeated-measures ANOVA. Recovery of MVC and CMJ was significantly improved with the HI compression garment (P < .05). A significant time-by-treatment interaction was also observed for jump height at 24 h postexercise (P < .05). No significant differences were observed for parameters of soreness and plasma CK, CRP, and Mb. The pressures exerted by a compression garment affect recovery after exercise-induced muscle damage, with higher pressure improving recovery of muscle function.
Hydrostatic Pressure Influences HIF-2 Alpha Expression in Chondrocytes
Inoue, Hiroaki; Arai, Yuji; Kishida, Tsunao; Terauchi, Ryu; Honjo, Kuniaki; Nakagawa, Shuji; Tsuchida, Shinji; Matsuki, Tomohiro; Ueshima, Keiichirou; Fujiwara, Hiroyoshi; Mazda, Osam; Kubo, Toshikazu
2015-01-01
Hypoxia-inducible factor (HIF)-2α is considered to play a major role in the progression of osteoarthritis. Recently, it was reported that pressure amplitude influences HIF-2α expression in murine endothelial cells. We examined whether hydrostatic pressure is involved in expression of HIF-2α in articular chondrocytes. Chondrocytes were cultured and stimulated by inflammation or hydrostatic pressure of 0, 5, 10, or 50 MPa. After stimulation, heat shock protein (HSP) 70, HIF-2α, nuclear factor kappa B (NF-κB), matrix metalloproteinase (MMP)-13, MMP-3, and vascular endothelial growth factor (VEGF) gene expression were evaluated. The levels of all gene expression were increased by inflammatory stress. When chondrocytes were exposed to a hydrostatic pressure of 5 MPa, HIF-2α, MMP-13, and MMP-3 gene expression increased significantly although those of HSP70 and NF-κB were not significantly different from the control group. In contrast, HIF-2α gene expression did not increase under a hydrostatic pressure of 50 MPa although HSP70 and NF-κB expression increased significantly compared to control. We considered that hydrostatic pressure of 5 MPa could regulate HIF-2α independent of NF-κB, because the level of HIF-2α gene expression increased significantly without upregulation of NF-κB expression at 5 MPa. Hydrostatic pressure may influence cartilage degeneration, inducing MMP-13 and MMP-3 expression through HIF-2α. PMID:25569085
Influence of intraoperative hypotension on leaks after sleeve gastrectomy.
Nienhuijs, Simon W; Kaymak, Uzay; Korsten, Erik; Buise, Marc P
2016-01-01
Leak after a sleeve gastrectomy (SG) is a severe complication. Risk factors, such as regional ischemia, increased intraluminal pressure, technical failure of the stapling device, and surgeon error, have been reported. It was hypothesized that intraoperative hypotension is another risk factor for leak, similar to that reported for colorectal surgery. Tertiary teaching hospital in The Netherlands. Results of a 7-year cohort of primary SGs were reviewed in relation to multiple intraoperative blood pressure measurements. The thresholds for the mean pressure were 40 to 70 mm Hg and for the systolic pressure 70 to 100 mm Hg. Only continuous episodes of 15 and 20 minutes were included. Twenty-four leaks were identified in a cohort of 1041 primary SGs. Episodes of systolic blood pressure<100 mm Hg for 15 min (P = .027) and 20 minutes (P = .008) were significantly related to a staple line leak. An episode of mean blood pressure<70 mm Hg for 20 min was significantly related to leak (P = .014). Episodes with lower thresholds of pressure occurred less frequently and revealed no significant differences. Other identified risk factors were smoking (P = .019), fast-track recovery program (P = .006), use of a tri-stapler (P = .004), and duration of surgery (P = .000). In a multivariate analysis, only intraoperative systolic pressure<100 mm Hg for 20 minutes remained significant (odds ratio, 2.45; P = .012). Intraoperative hypotension may contribute independently to a leak after SG. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Tang, Ke-Qiang; Yang, Shao-Ling; Zhang, Bin; Liu, Hong-Xiang; Ye, Dong-Ying; Zhang, Hong-Ze; Ma, Shuang
2017-09-01
The aim of this study was to explore the clinical value of ultrasonic monitoring in the assessment of pulmonary recruitment and the best positive end-expiratory pressure (PEEP).Between January 2015 and June 2017, 40 patients with acute respiratory distress syndrome in our hospital were randomly divided into 2 groups: ultrasound group (ULS group; n = 20) and oxygenation group (OXY group; n = 20). The PEEP incremental method was used to perform recruitment maneuvers. Ultrasound scoring and the oxygenation method were used to evaluate the pulmonary recruitment endpoint. The best PEEP was chosen by ultrasound scoring and the oxygenation method after achieving the pulmonary recruitment endpoint and sustaining it for 15 minutes.The oxygenation index, PEEP, peak airway pressure (Ppeak), mean airway pressure (Pmean), and dynamic compliance (Cdyn) in the OXY group were significantly lower than those in the ULS group (P < .05) at the pulmonary recruitment endpoint; however, there was no statistical significance in the mean arterial blood pressure (MAP) or heart rate (HR) (P > .05). The best PEEPs in the OXY and ULS groups were 13.1 ± 3.1 and 15.7 ± 4.2 cmH2O, respectively, with a significant difference between the 2 groups (t = 2.227, P = .016). Compared with the basal state, the Cdyn, oxygenation index, Pmean, and Ppeak in both groups significantly increased after pulmonary recruitment (P < .05). Furthermore, the Cdyn and oxygenation index in the ULS group were significantly higher than those in the OXY group after pulmonary recruitment (P < .05). The HR in both groups significantly increased, and the MAP significantly decreased. Two hours after recruitment, the HR and MAP returned to near basal levels without a significant difference between the 2 groups (P > .05).Lung ultrasound can be used to detect the endpoint of lung recruitment and the best PEEP, with good effects on lung compliance and oxygenation improvement.
Firmani, Mónica; Miralles, Rodolfo; Casassus, Rodrigo
2015-04-01
To compare the effects of 5% lidocaine patches and placebo patches on pain intensity and electromyographic (EMG) activity of an active myofascial trigger point (MTrP) of the upper trapezius muscle. Thirty-six patients with a MTrP in the upper trapezius muscle were randomly divided into two groups: 20 patients received lidocaine patches (lidocaine group) and 16 patients received placebo patches (placebo group). They used the patches for 12 h each day, for 2 weeks. The patch was applied to the skin over the upper trapezius MTrP. Spontaneous pain, pressure pain thresholds, pain provoked by a 4-kg pressure applied to the MTrP and trapezius EMG activity were measured before and after treatment. Baseline spontaneous pain values were similar in both groups and significantly lower in the lidocaine group than the placebo group after treatment. The baseline pressure pain threshold was significantly lower in the lidocaine group, but after treatment it was significantly higher in this group. Baseline and final values of the pain provoked by a 4-kg pressure showed no significant difference between the groups. Baseline EMG activity at rest and during swallowing of saliva was significantly higher in the lidocaine group, but no significant difference was observed after treatment. Baseline EMG activity during maximum voluntary clenching was similar in both groups, but significantly higher in the lidocaine group after treatment. These clinical and EMG results support the use of 5% lidocaine patches for treating patients with MTrP of the upper trapezius muscle.
Huang Foen Chung, J W N C; Bohnen, A M; Pel, J J M; Bosch, J L H R; Niesing, R; van Mastrigt, R
2004-01-01
To report on the applicability, reproducibility, and adverse events of the noninvasive condom catheter method in the first 730 subjects of a longitudinal survey of changes in urinary bladder contractility secondary to benign prostatic hyperplasia, in which 1300 men will be evaluated three times in 5 years using this method. Subjects were recruited by general practitioners, general publicity, and e-mail. Only those meeting the study criteria were entered in the study. If the free flow rate exceeded 5.4 mL/s, at least two consecutive condom pressure measurements were attempted using the condom catheter method. The condom pressure measured reflected the isovolumetric bladder pressure, a measure of urinary bladder contractility. The reproducibility of the method was quantified by a difference plot of the two maximal condom pressures measured in each subject. In 618 (94%) of 659 eligible participants, one condom pressure measurement was completed; two measurements were done in 555 (84%). The maximal condom pressure ranged from 28 to 228 cm H2O (overall mean 101, SD 34). A difference between the two pressures of less than +/-21 cm H2O was found in 80%. The mean difference was -1 cm H2O (SD 18), significantly different from 0. Some adverse events such as terminal self-limiting hematuria were encountered. The condom catheter method is very suitable for large-scale use. It has a success rate of 94% and a reproducibility comparable to that of invasive pressure flow studies.
Intramedullary pressure changes in rats after spinal cord injury.
Dong, X; Yang, D; Li, J; Liu, C; Yang, M; Du, L; Gu, R; Hu, A; Zhang, H
2016-11-01
The objectives of this study were to explore the change of intramedullary pressure over time in rats after different degrees of spinal cord contusion injury and to verify the hypothesis that the more serious the injury, the higher the intramedullary pressure. The control group rats underwent laminectomy only, whereas the rats in the three experimental groups were subjected to mild, moderate or severe 10th thoracic cord (T10) contusion injury after laminectomy. In addition, an intramedullary pressure of T10 was measured by a Millar Mikro-Tip pressure catheter (Millar Incorporated Company, Houston, TX, USA) immediately in the control group or at different time points after injury in the experimental groups. The average intramedullary pressure of the rats in the control group was 6.88±1.67 mm Hg, whereas that of the rats in any injury group was significantly higher (P=0.000). There was statistical difference among the different time points in the mild or moderate injury group (P=0.007/0.017), but no in the severe (P=0.374). The curves of intramedullary pressure over time in the mild and moderate injury group were bimodal, peaking at 1 and 48 h after the injury. The intramedullary pressure after injury was positively correlated with the injury degree (r=0.438, P=0.000). The intramedullary pressure of the rats increased after traumatic spinal cord injury. If the injury was not serious, the intramedullary pressure fluctuated with time and peaked at 1 and 48 h after injury. If the injury was serious, the intramedullary pressure remained high. The more serious the injury, the higher the intramedullary pressure.
Patterns of correlation between vehicle occupant seat pressure and anthropometry.
Paul, Gunther; Daniell, Nathan; Fraysse, François
2012-01-01
Seat pressure is known as a major factor of seat comfort in vehicles. In passenger vehicles, there is lacking research into the seat comfort of rear seat occupants. As accurate seat pressure measurement requires significant effort, simulation of seat pressure is evolving as a preferred method. However, analytic methods are based on complex finite element modeling and therefore are time consuming and involve high investment. Based on accurate anthropometric measurements of 64 male subjects and outboard rear seat pressure measurements in three different passenger vehicles, this study investigates if a set of parameters derived from seat pressure mapping are sensitive enough to differentiate between different seats and whether they correlate with anthropometry in linear models. In addition to the pressure map analysis, H-Points were measured with a coordinate measurement system based on palpated body landmarks and the range of H-Point locations in the three seats is provided. It was found that for the cushion, cushion contact area and cushion front area/force could be modeled by subject anthropometry, while only seatback contact area could be modeled based on anthropometry for all three vehicles. Major differences were found between the vehicles for other parameters.
Abdominal drainage following cholecystectomy: high, low, or no suction?
McCormack, T. T.; Abel, P. D.; Collins, C. D.
1983-01-01
A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study failed to demonstrate any clinically useful difference between high negative pressure, low negative pressure, and static drainage system were compared: a simple tube drain, a low negative used, suction is not necessary and a simple tube drain (greater than 6 mm internal diameter) is the most effective form of drainage. PMID:6614773
Tokuda, Naoto; Kitaoka, Yasushi; Matsuzawa, Akiko; Tsukamoto, Ayaka; Sase, Kana; Sakae, Shinsuke; Takagi, Hitoshi
2017-01-01
The aim of the present study was to examine the effects of switching from Latanoprost ophthalmic solution containing a preservative to preservative-free Tafluprost ophthalmic solution or Tafluprost containing a preservative on ocular surfaces. Forty patients (40 eyes) with glaucoma (mean age: 62.0 ± 10.9 years) using Latanoprost with preservative for six months or longer were assigned either to a Tafluprost-containing-preservative group (20 eyes) or preservative-free-Tafluprost group (20 eyes). The intraocular pressure, corneal epithelial barrier function (fluorescein uptake concentration with fluorophotometer FL-500), superficial punctate keratopathy (AD classification), and tear film breakup time (TBUT) were assessed before switching and at 12 weeks after switching. No significant differences in intraocular pressure were noted after switching in either group. Corneal epithelial barrier function was improved significantly after switching in both the Tafluprost-containing-preservative and the preservative-free-Tafluprost groups. There were no significant differences in AD scores after switching in the Tafluprost-containing-preservative group, but significant improvements were noted in the preservative-free-Tafluprost group. No significant differences in TBUT were noted in the Tafluprost-containing-preservative or preservative-free-Tafluprost groups after switching. After switching from preservative Latanoprost to Tafluprost containing-preservative or preservative-free Tafluprost, corneal epithelial barrier function was improved while the intraocular pressure reduction was retained.
Isgrò, S; Zanella, A; Giani, M; Abd El Aziz El Sayed Deab, S; Pesenti, A; Patroniti, N
2012-10-01
Aim of the paper was to assess the performance of different expiratory valves and the resistance of helmet outlet ports at increasing gas flow rates. A gas flow-meter was connected to 10 different expiratory peep valves: 1 water-seal valve, 4 precalibrated fixed PEEP valves and 5 adjustable PEEP valves. Three new valves of each brand, set at different pressure levels (5-7.5-10-12.5-15 cmH(2)O, if available), were tested at increasing gas flow rates (from 30 to 150 L/min). We measured the pressure generated just before the valves. Three different helmets sealed on a mock head were connected at the inlet port with a gas flow-meter while the outlet was left clear. We measured the pressure generated inside the helmet (due to the flow-resistance of the outlet port) at increasing gas flow rates. Adjustable valves showed a variable degree flow-dependency (increasing difference between the measured and the expected pressure at increasing flow rates), while pre-calibrated valves revealed a flow-independent behavior. Water seal valve showed low degree flow-dependency. The pressures generated by the outlet port of the tested helmets ranged from 0.02 to 2.29 cmH(2)O at the highest gas flow rate. Adjustable PEEP valves are not suggested for continuous-flow CPAP systems as their flow-dependency can lead to pressures higher than expected. Precalibrated and water seal valves exhibit the best performance. Different helmet outlet ports do not significantly affect the pressure generated during helmet CPAP. In order to avoid iatrogenic complications gas flow and pressure delivered during helmet CPAP must always be monitored.
Bauer, Karen; Rock, Kathryn; Nazzal, Munier; Jones, Olivia; Qu, Weikai
2016-11-01
Pressure ulcers are common, increase patient morbidity and mortality, and costly for patients, their families, and the health care system. A retrospective study was conducted to evaluate the impact of pressure ulcers on short-term outcomes in United States inpatient populations and to identify patient characteristics associated with having 1 or more pressure ulcers. The US Nationwide Inpatient Sample (NIS) database was analyzed using the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9 CM) diagnosis codes as the screening tool for all inpatient pressure ulcers recorded from 2008 to 2012. Patient demographics and comorbid conditions, as identified by ICD-9 code, were extracted, along with primary outcomes of length of stay (LOS), total hospital charge (TC), inhospital mortality, and discharge disposition. Continuous variables with normal distribution were expressed in terms of mean and standard deviation. Group comparisons were performed using t-test or ANOVA test. Continuous nonnormal distributed variables such as LOS and TC were expressed in terms of median, and nonparametric tests were used to compare the differences between groups. Categorical data were presented in terms of percentages of the number of cases within each group. Chi-squared tests were used to compare categorical data in different groups. For multivariate analysis, linear regressions (for continuous variable) and logistic regression (for categorical variables) were used to analyze the possible risk factors for the investigated outcomes of LOS, TC, inhospital mortality, and patient disposition. Coefficients were calculated with multivariate regression with all included patients versus patients with pressure ulcers alone. The 5-year average number of admitted patients with at least 1 pressure ulcer was determined to be 670 767 (average overall rate: 1.8%). Statistically significant differences between patients with and without pressure ulcers were observed for median LOS (7 days [mean 11.1 ± 15] compared to 3 days [mean 4.6 ± 6.8]) and median TC ($36 500 [mean $72 000 ± $122 900] compared to $17 200 [mean $32 200 ± $57 500]). The mortality rate in patients with a pressure ulcer was significantly higher than in patients without a pressure ulcer (9.1% versus 1.8%, OR = 5.08, CI: 5.03-5.1, P <0.001). Pressure ulcers were significantly more common in patients who were older or had malnutrition. The results of this study confirm the importance of prevention initiatives to help reduce the negative impact of pressure ulcers on patient outcomes and costs of care.
Mulcahy, D M; McCormack, D M; Stephens, M M
1998-12-01
Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.
Effect of Casting Material on the Cast Pressure After Sequential Cast Splitting.
Roberts, Aaron; Shaw, K Aaron; Boomsma, Shawn E; Cameron, Craig D
2017-01-01
Circumferential casting is a vital component of nonoperative fracture management. These casts are commonly valved to release pressure and decrease the risk of complications from swelling. However, little information exists regarding the effect of different casting supplies on the pressure within the cast. Seventy-five long-arm casts were performed on human volunteers, divided between 5 experimental groups with 15 casts in each groups. Testing groups consisted of 2 groups with a plaster short-arm cast overwrapped with fiberglass to a long arm with either cotton or synthetic cast padding. The 3 remaining groups included fiberglass long-arm casts with cotton, synthetic, or waterproof cast padding. A pediatric blood pressure cuff bladder was placed within the cast and inflated to 100 mm Hg. After inflation, the cast was sequentially released with pressure reading preformed after each stage. Order of release consisted of cast bivalve, cast padding release, and cotton stockinet release. After release, the cast was overwrapped with a loose elastic bandage. Difference in pressure readings were compared based upon the cast material. Pressures within the cast were found to decrease with sequential release of cast. The cast type had no effect of change in pressure. Post hoc testing demonstrated that the type of cast padding significantly affected the cast pressures with waterproof padding demonstrating the highest pressure readings at all time-points in the study, followed by synthetic padding. Cotton padding had the lowest pressure readings at all time-points. Type of cast padding significantly influences the amount of pressure within a long-arm cast, even after bivalving the cast and cutting the cast padding. Cotton cast padding allows for the greatest change in pressure. Cotton padding demonstrates the greatest change in pressure within a long-arm cast after undergoing bivalve. Synthetic and waterproof cast padding should not be used in the setting of an acute fracture to accommodate swelling.
Comparison of air-charged and water-filled urodynamic pressure measurement catheters.
Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S
2011-03-01
Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.
The impact of arm position on the measurement of orthostatic blood pressure.
Guss, David A; Abdelnur, Diego; Hemingway, Thomas J
2008-05-01
Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p < 0.0001). Arm position has a significant impact on determination of postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic change in blood pressure.
Kato, Masayuki; Jung, Yunho; Gromski, Mark A; Chuttani, Ram; Matthes, Kai
2012-01-01
Recently, endoscopic clip application devices have undergone redesign and improvements to optimize their clinical use and effectiveness. Initially designed for the treatment of bleeding nonvariceal lesions, these devices are also increasingly used for the closure of perforations, fistulas, and anastomotic leaks. Several clinical studies, both randomized and nonrandomized, have used endoscopic hemoclips for hemostasis. However, no comparative studies have yet been reported in the literature comparing the latest endoscopic clip devices for usability and effectiveness for hemostasis of acute upper GI hemorrhage. We aimed to compare the usability and efficacy of 3 different types of endoscopic clip application devices in an established experimental setting by using a porcine ex-vivo simulator of upper GI hemorrhage. Randomized, controlled, ex-vivo study. Academic medical center. Spurting vessels were created within ex-vivo porcine stomachs as published in prior studies. The vessels were attached to a pressure transducer to record the pressure of the circulating blood replacement. Before the initiation of bleeding, each vessel was randomized to 1 of 3 endoscopic clipping devices: 2 different commonly used hemoclips deployed through the working channel and 1 novel clip deployed via an over-the-scope applications device. Two investigators treated 45 bleeding sites (15 bleeding sites for each device at various randomized locations in the stomach: fundus, body, and antrum). Usability was measured via the endpoints of procedure time and quantity of clips required to achieve hemostasis. Efficacy was measured via the endpoint of pressure increase (Δp) from baseline to after treatment. All of the 45 hemostasis treatments were carried out successfully. The mean procedure times were significantly different among the hemoclips, with the clip deployed in an over-the-scope fashion requiring significantly less time to attain hemostasis compared with the other 2 clips. For number of clips needed to attain hemostasis, the clip deployed in an over-the-scope fashion was significantly superior to the others. There were also significant differences among the changes in pressure (Δp ± SD) among the different hemoclips tested. Ex-vivo study. In this prospective, randomized ex-vivo study, we observed significant differences in the usability (time to achieve hemostasis and number of clips required) and the efficacy (change in pressure achieved by the hemoclips) among the 3 clips. The clip applied in the over-the-scope fashion was superior to the other 2 tested clips with regard to time to achieve hemostasis and number of clips required. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Tobe, Sheldon W; Pylypchuk, George; Wentworth, Joan; Kiss, Alexander; Szalai, John Paul; Perkins, Nancy; Hartman, Susan; Ironstand, Laurie; Hoppe, Jacqueline
2006-04-25
First Nations people with diabetes mellitus and hypertension are at greater risk of renal and cardiovascular complications than are non-native patients because of barriers to health care services. We conducted this randomized controlled trial to assess whether a community-based treatment strategy implemented by home care nurses would be effective in controlling hypertension in First Nations people with existing hypertension and type 2 diabetes. We compared 2 community-based strategies for controlling hypertension in First Nations people with existing hypertension and diabetes. In the intervention group, a home care nurse followed a predefined treatment algorithm of pharmacologic antihypertensive therapy. In the control group, treatment decisions were made by each subject's primary care physician. The primary outcome measure was the difference between the 2 groups in the change in systolic blood pressure after 12 months. Secondary outcome measures were the change in diastolic blood pressure over time, the change in urine albumin status and the incidence of adverse events. Both groups experienced a significant reduction in systolic blood pressure by the final visit (by 24.0 [standard deviation (SD) 13.5] mm Hg in the intervention group and by 17.0 [SD 18.6] mm Hg in the control group); p < 0.001 in each case). However, the difference between the 2 groups in this change was not significant. Patients in the intervention group had a larger decrease in diastolic blood pressure over time than did those in the control group (by 11.6 [SD 10.6] mm Hg v. 6.8 [SD 11.1] mm Hg respectively; p = 0.05). The groups did not differ significantly in terms of changes in urine albumin excretion or incidence of adverse events. High rates of blood pressure control in the community were achieved in both groups in the DREAM 3 study. The addition of a home care nurse to implement a treatment strategy for blood pressure control was more effective in lowering diastolic than systolic blood pressure compared with home care visits for blood pressure monitoring alone and follow-up treatment by a family physician.
Sequist, Thomas D.; Ayanian, John Z.; Shaykevich, Shimon; Fairchild, David G.; Orav, E. John; Bates, David W.
2008-01-01
BACKGROUND We conducted a cluster randomized controlled trial to examine the effectiveness of computerized decision support (CDS) designed to improve hypertension care and outcomes in a racially diverse sample of primary care patients. METHODS We randomized 2,027 adult patients receiving hypertension care in 14 primary care practices to either 18 months of their physicians receiving CDS for each hypertensive patient or to usual care without computerized support for the control group. We assessed prescribing of guideline-recommended drug therapy and levels of blood pressure control for patients in each group and examined if the effects of the intervention differed by patients’ race/ethnicity using interaction terms. MEASUREMENTS AND MAIN RESULTS Rates of blood pressure control were 42% at baseline and 46% at the outcome visit with no significant differences between groups. After adjustment for patients’ demographic and clinical characteristics, number of prior visits, and levels of baseline blood pressure control, there were no differences between intervention groups in the odds of outcome blood pressure control. The use of CDS to providers significantly improved Joint National Committee (JNC) guideline adherent medication prescribing compared to usual care (7% versus 5%, P < 0.001); the effects of the intervention remained after multivariable adjustment (odds ratio [OR] 1.39 [CI, 1.13–1.72]) and the effects of the intervention did not differ by patients’ race and ethnicity. CONCLUSIONS CDS improved appropriate medication prescribing with no improvement in disparities in care and overall blood pressure control. Future work focusing on improvement of these interventions and the study of other practical interventions to reduce disparities in hypertension-related outcomes is needed. PMID:18373141
Deng, Yi-Jun; Ji, You-Lin; Chen, Lan-Ping; Jin, Qin
2011-04-01
To observe the effects of combining positive pressure ventilation with diaphragm pacing on respiratory mechanics in patients with respiratory failure. Twenty patients with central respiratory failure were studied with cohorts. The effects on respiratory mechanics were respectively observed in patients in control group, in whom ventilation by positive pressure only, and patients in experimental group in whom ventilation was instituted by combining positive pressure ventilation with diaphragm pacing. Compared with control group, mean airway pressure (Paw, cm H(2)O, 1 cm H(2)O= 0.098 kPa) and plateau pressure (Pplat, cm H(2)O) were significantly decreased in experimental group (Paw: 6.1±1.3 vs. 7.3±1.8; Pplat: 10.4±2.5 vs. 12.1±2.6, both P<0.05), while the negative value of peak esophageal pressure (P(PEAK ES) , cm H(2)O), the negative value of the difference between peak and basic esophageal pressure (dP(ES), cm H(2)O), transpulmonary pressure at end of inspiration hold (Ptp plat, cm H(2)O ), static compliance (Cst, ml/cm H(2)O) were significantly increased in experimental group (P(PEAK ES): -8.3± 1.9 vs. -3.2±1.4; dP(ES) : -11.2±2.6 vs. -8.2±2.2; Ptp plat: 23.6±3.8 vs. 15.6±3.1; Cst: 52.7±8.2 vs. 48.3±7.2, all P<0.05). No differences were found in airway resistance (Raw, cm H(2)O×L(-1) ×s(-1) ) and lung resistance (R(L), cm H(2)O×L(-1) ×s(-1) ) between experimental group and control group (Raw: 2.1±0.5 vs. 2.3±0.4; R(L): 2.9±0.6 vs. 3.1±0.5, both P>0.05). Work of breath by patient (WOBp, J/L) was significantly increased and work of breath by ventilator (WOBv, J/L) was significantly decreased in experimental group compared with control group (WOBp: 0.18±0.03 vs. 0; WOBv: 0.31±0.07 vs. 0.53±0.11, both P<0.05). Compared with positive pressure ventilation , positive pressure ventilation combined with diaphragm pacing can decrease the Paw, increase intrathoracic negative pressure, transpulmonary pressure, and Cst, and decrease WOBv, while there is no effect on Raw and R(L).
Demarré, L; Beeckman, D; Vanderwee, K; Defloor, T; Grypdonck, M; Verhaeghe, S
2012-04-01
The duration and the amount of pressure and shear must be reduced in order to minimize the risk of pressure ulcer development. Alternating low pressure air mattresses with multi-stage inflation and deflation cycle of the air cells have been developed to relieve pressure by sequentially inflating and deflating the air cells. Evidence about the effectiveness of this type of mattress in clinical practice is lacking. This study aimed to compare the effectiveness of an alternating low pressure air mattress that has a standard single-stage inflation and deflation cycle of the air cells with an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. A randomised controlled trial was performed in a convenience sample of 25 wards in five hospitals in Belgium. In total, 610 patients were included and randomly assigned to the experimental group (n=298) or the control group (n=312). In the experimental group, patients were allocated to an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. In the control group, patients were allocated to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. The outcome was defined as cumulative pressure ulcer incidence (Grade II-IV). An intention-to-treat analysis was performed. There was no significant difference in cumulative pressure ulcer incidence (Grade II-IV) between both groups (Exp.=5.7%, Contr.=5.8%, p=0.97). When patients developed a pressure ulcer, the median time was 5.0 days in the experimental group (IQR=3.0-8.5) and 8.0 days in the control group (IQR=3.0-8.5) (Mann-Whitney U-test=113, p=0.182). The probability to remain pressure ulcer free during the observation period in this trial did not differ significantly between the experimental group and the control group (log-rank χ(2)=0.013, df=1, p=0.911). An alternating low pressure air mattress with multi-stage inflation and deflation of the air cells does not result in a significantly lower pressure ulcer incidence compared to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. Both alternating mattress types are equally effective to prevent pressure ulcer development. © 2011 Elsevier Ltd. All rights reserved.
Honda, M; Izumi, Y; Hatano, M
1988-08-20
The influence of a Mg-deficient diet on blood pressure and various hormonal systems was examined in Wistar rats (WR) and spontaneously hypertensive rats (SHR). The WR and SHR were individually divided into 2 groups. The Mg-deficient diet was given to one group, and a Mg-containing diet was given to the other group for 3 weeks. During this experimental period, the body weight, blood pressure, urine volume, blood and urinary electrolytes, plasma steroid hormones, plasma renin activity (PRA), and urinary hormones [kinin, prostaglandin E2 (PGE2), 6-keto-prostaglandin F1 alpha (6-keto-PGF1 alpha), and noradrenaline] were examined. Although no significant difference in body weight was observed between the Mg-deficient and Mg-containing diet groups in either the WR or SHR (because the experiments were performed in a pair-fed fashion in both kinds of rat), the blood pressure was increased in the Mg-containing diet group but was unchanged in the Mg-deficient diet group. As regards changes in electrolytes, a decreased urinary excretion of Mg and significantly increased urinary excretion of P were observed in the Mg-deficient diet group in both the WR and SHR. Furthermore, decreased levels of serum Mg and P and increased levels of serum Ca were also noted. In the WR group, the urinary excretion of noradrenaline was significantly increased in the Mg-deficient diet group as compared to the Mg-containing diet group. However, the change was reversed in the SHR group. The plasma steroid hormones and PRA were both significantly low in the Mg-deficient diet group in both the WR and SHR. The urinary excretions of PGE2, 6-keto-PGF1 alpha, and kinin showed no significant differences between the two diet groups. The above results indicate that blood pressure is not affected by the Mg-deficient diet in either the WR or SHR, and the possible participation of the sympathetic nervous system in the mechanism of control of blood pressure may differ somewhat between the WR and SHR. In addition, Mg ion was found to play an important role in the biosynthesis of renin and steroid hormones but to have no such significant role in the urinary excretions of kinin, PGE2, and 6-keto-PGF1 alpha.
The effect of the rate of hydrostatic pressure depressurization on cells in culture.
Tworkoski, Ellen; Glucksberg, Matthew R; Johnson, Mark
2018-01-01
Changes in hydrostatic pressure, at levels as low as 10 mm Hg, have been reported in some studies to alter cell function in vitro; however, other studies have found no detectable changes using similar methodologies. We here investigate the hypothesis that the rate of depressurization, rather than elevated hydrostatic pressure itself, may be responsible for these reported changes. Hydrostatic pressure (100 mm Hg above atmospheric pressure) was applied to bovine aortic endothelial cells (BAECs) and PC12 neuronal cells using pressurized gas for periods ranging from 3 hours to 9 days, and then the system was either slowly (~30 minutes) or rapidly (~5 seconds) depressurized. Cell viability, apoptosis, proliferation, and F-actin distribution were then assayed. Our results did not show significant differences between rapidly and slowly depressurized cells that would explain differences previously reported in the literature. Moreover, we found no detectable effect of elevated hydrostatic pressure (with slow depressurization) on any measured variables. Our results do not confirm the findings of other groups that modest increases in hydrostatic pressure affect cell function, but we are not able to explain their findings.
The effect of the rate of hydrostatic pressure depressurization on cells in culture
Tworkoski, Ellen; Glucksberg, Matthew R.
2018-01-01
Changes in hydrostatic pressure, at levels as low as 10 mm Hg, have been reported in some studies to alter cell function in vitro; however, other studies have found no detectable changes using similar methodologies. We here investigate the hypothesis that the rate of depressurization, rather than elevated hydrostatic pressure itself, may be responsible for these reported changes. Hydrostatic pressure (100 mm Hg above atmospheric pressure) was applied to bovine aortic endothelial cells (BAECs) and PC12 neuronal cells using pressurized gas for periods ranging from 3 hours to 9 days, and then the system was either slowly (~30 minutes) or rapidly (~5 seconds) depressurized. Cell viability, apoptosis, proliferation, and F-actin distribution were then assayed. Our results did not show significant differences between rapidly and slowly depressurized cells that would explain differences previously reported in the literature. Moreover, we found no detectable effect of elevated hydrostatic pressure (with slow depressurization) on any measured variables. Our results do not confirm the findings of other groups that modest increases in hydrostatic pressure affect cell function, but we are not able to explain their findings. PMID:29315329
Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma
Shen, Christopher C; Salim, Sarwat; Du, Haiming; Netland, Peter A
2011-01-01
Purpose: To compare surgical outcomes in neovascular glaucoma patients who underwent trabeculectomy with mitomycin C versus Ahmed Glaucoma Valve implantation. Patients and methods: This was a retrospective comparative case series. We reviewed 40 eyes of 39 patients with underlying diagnosis of neovascular glaucoma, divided into two groups: Ahmed Glaucoma Valve (N = 20) and trabeculectomy with mitomycin C (N = 20). Surgical success was defined as 6 mm Hg ≤ intraocular pressure ≤21 mm Hg, with or without the use of glaucoma medications, with no further glaucoma surgery, and light perception or better vision. Early postoperative hypotony was defined as intraocular pressure <5 mm Hg during the first postoperative week. Results: The average follow-up was 31 months (range 6–87 months) for the Ahmed Glaucoma Valve group and 25 months (6–77 months) for the trabeculectomy group. Although the mean number of postoperative intraocular pressure-lowering medications was significantly higher in the trabeculectomy group compared with the Ahmed Glaucoma Valve group at 3 and 6 month time points, there was no statistically significant difference at any other time point. There was no statistically significant difference between both groups in postoperative visual acuity and intraocular pressure. Success was 70% and 65% at 1 year and 60% and 55% at 2 years after Ahmed Glaucoma Valve and trabeculectomy, respectively. Kaplan–Meier survival curve analysis showed no significant difference in success between the two groups (P = 0.815). Hyphema was the most common complication in both groups. Conclusion: We found similar results after trabeculectomy with mitomycin C and Ahmed Glaucoma Valve implantation in eyes with neovascular glaucoma. PMID:21468334
Spatial distribution of vaginal closure pressures of continent and stress urinary incontinent women.
Peng, Qiyu; Jones, Ruth; Shishido, Keiichi; Omata, Sadao; Constantinou, Christos E
2007-11-01
Clinically the strength of the contraction of the female pelvic floor is qualitatively evaluated by vaginal tactile palpation. We therefore developed a probe to enable the quantitative evaluation of the closure pressures along the vagina. Four force sensors mounted on the four orthogonal directions of an intra-vaginal probe were used to measure the vaginal pressure profile (VPP) along the vaginal wall. Clinical experiments on 23 controls and 10 patients with stress urinary incontinence (SUI) were performed using the probe to test the hypothesis that the strength of pelvic floor muscle (PFM) contractions, imposed by voluntary contraction, is related to urinary continence. The results show that VPPs, characterized in terms of pressure distribution on the anterior and posterior vaginal walls, are significantly greater than those in the left and right vaginal walls. When the PFM contracted, the positions of the maximum posterior pressures in continent females and SUI patients were 0.63+/-0.15 cm and 1.19+/-0.2 cm proximal from their peak points of anterior pressure, which are 1.52+/-0.09 cm and 1.69+/-0.13 cm proximal from the introitus of vagina, respectively. The statistical analysis shows that the maximum posterior vaginal pressures of the controls were significantly greater than those of the SUI patients both at rest (continent: 3.4+/-0.3 N cm(-2), SUI: 2.01+/-0.36 N cm(-2), p<0.05) and during PFM contraction (continent: 4.18+/-0.26 N cm(-2), SUI: 2.25+/-0.41 N cm(-2), p<0.01). In addition, the difference between the posterior and anterior vaginal walls is significantly increased when the controls contract the PFM. By contrast, there are no significant differences in the SUI group. The results show that the VPP measured by the prototype probe can be used to quantitatively evaluate the strength of the PFM, which is a clinical index for the diagnosis or assessment of female SUI.
Orthogonal P-wave morphology is affected by intra-atrial pressures.
Petersson, Richard; Smith, J Gustav; Larsson, David A; Reitan, Öyvind; Carlson, Jonas; Platonov, Pyotr; Holmqvist, Fredrik
2017-12-06
It has previously been shown that the morphology of the P-wave neither depends on atrial size in healthy subjects with physiologically enlarged atria nor on the physiological anatomical variation in transverse orientation of the left atrium. The present study aimed to investigate if different pressures in the left and right atrium are associated with different P-wave morphologies. 38 patients with isolated, increased left atrial pressure, 51 patients with isolated, increased right atrial pressure and 76 patients with biatrially increased pressure were studied. All had undergone right heart catheterization and had 12-lead electrocardiographic recordings, which were transformed into vectorcardiograms for detailed P-wave morphology analysis. Normal P-wave morphology (type 1) was more common in patients with isolated increased pressure in the right atrium while abnormal P-wave morphology (type 2) was more common in the groups with increased left atrial pressure (P = 0.032). Moreover, patients with increased left atrial pressure, either isolated or in conjunction with increased right atrial pressure, had significantly more often a P-wave morphology with a positive deflection in the sagittal plane (P = 0.004). Isolated elevated right atrial pressure was associated with normal P-wave morphology while left-sided atrial pressure elevation, either isolated or in combination with right atrial pressure elevation, was associated with abnormal P-wave morphology.
Kalantary, Saba; Dehghani, Ali; Yekaninejad, Mir Saeed; Omidi, Leila; Rahimzadeh, Mitra
2015-01-01
BACKGROUND One of the most important impacts of industrial noise is physiological and psychological effects. The increases in workers’ blood pressure and heart rate were detected during and after exposure to high levels of noise. The objectives of this research were to determine whether the noise exposures have any effects on blood pressure and heart rate of workers in the automotive parts industry. METHODS This case study was done in 2011 at different units of an automotive parts manufacturing in Tehran. Sound pressure level was measured at different units of the factory with a calibrated instrument. Demographic features of workers were gathered with an appropriate questionnaire. Heart rate and blood pressure were measured twice in a day in the start time of work day (before exposure to noise) and middle shift hours (during exposure to noise) in the occupational physician office. For analyzing data, chi-square, independent sample t-test, paired t-test, and analysis of covariance (ANCOVA) were used. P < 0.050 was considered statistically significant. RESULTS The average age of workers in the case and control groups was 35.71 ± 8.10 and 33.40 ± 10.41 years, respectively. There was no difference between the average age of case and control groups (P = 0.436). The results of ANCOVA revealed the significant differences between the mean changes of heart rate F (1, 37) = 26.68, P < 0.001, systolic blood pressure F (1, 37) = 21.70, P < 0.001, and diastolic blood pressure F (1, 37) = 26.20, P < 0.001 of workers in the case and control groups. CONCLUSION Exposure to industrial noise may increase the heart rate of workers. Although rises in heart rate, systolic, and diastolic blood pressure of workers in the case group were observed after exposure to noise, the values of heart rate, systolic, and diastolic blood pressure were in the normal range. Further experimental investigations are needed to determine the relationships between these variables. PMID:26478728
An anti-barotrauma system for preventing barotrauma during hyperbaric oxygen therapy.
Song, Moon; Hoon, Se Jeon; Shin, Tae Min
2018-01-01
In the present study, a tympanometry-based anti-barotrauma (ABT) device was designed using eardrum admittance measurements to develop an objective method of preventing barotrauma that occurs during hyperbaric oxygen (HBO₂) therapy. The middle ear space requires active equalization, and barotrauma of these tissues during HBO₂therapy constitutes the most common treatment-associated injury. Decongestant nasal sprays and nasal steroids are used, but their efficacy is questionable to prevent middle ear barotrauma (MEB) during HBO₂ treatment. Accordingly, a tympanometry-based ABT device was designed using eardrum admittance measurements to develop an objective method for preventing MEB, which causes pain and injury, and represents one of the principal reasons for patients to stop treatment. This study was conducted to test a novel technology that can be used to measure transmembrane pressures, and provide chamber attendants with real-time feedback regarding the patient's equalization status prior to the onset of pain or injury. Eardrum admittance values were measured according to pressure changes inside a hyperbaric oxygen chamber while the system was fitted to the subject. When the pressure increased to above 200 daPa, eardrum admittance decreased to 16.255% of prepressurization levels. After pressure equalization was achieved, eardrum admittance recovered to 95.595% of prepressurization levels. A one-way repeated measures analysis of variance contrast test was performed on eardrum admittance before pressurization versus during pressurization, and before pressurization versus after pressure equalization. The analysis revealed significant differences at all points during pressurization (P⟨0.001), but no significant difference after pressure equalization was achieved. This ABT device can provide objective feedback reflecting eardrum condition to the patient and the chamber operator during HBO₂ therapy. Copyright© Undersea and Hyperbaric Medical Society.
Artico, Marco; D'Angelo, Daniela; Piredda, Michela; Petitti, Tommasangelo; Lamarca, Luciano; De Marinis, Maria Grazia; Dante, Angelo; Lusignani, Maura; Matarese, Maria
2018-07-01
Patients with advanced illnesses show the highest prevalence for pressure injuries. In the palliative care setting, the ultimate goal is injury healing, but equally important is wound maintenance, wound palliation (wound-related pain and symptom management), and primary and secondary wound prevention. To describe the course of healing for pressure injuries in a home palliative care setting according to different end-points, and to explore patient and caregiver characteristics and specific care activities associated with their achievement. Four-year retrospective chart review of 669 patients cared for in a home palliative care service, of those 124 patients (18.5%) had at least one pressure injury with a survival rate less than or equal to six months. The proportion of healed pressure injuries was 24.4%. Of the injuries not healed, 34.0% were in a maintenance phase, whereas 63.6% were in a process of deterioration. Body mass index (P = 0.0014), artificial nutrition (P = 0.002), and age <70 years (P = 0.022) emerged as predictive factors of pressure injury complete healing. Artificial nutrition, age, male caregiver (P = 0.034), and spouse (P = 0.036) were factors significantly associated with a more rapid pressure injury healing. Continuous deep sedation was a predictive factor for pressure injury deterioration and significantly associated with a more rapid worsening. Pressure injury healing is a realistic aim in home palliative care, particularly for injuries not exceeding Stage II occurring at least two weeks before death. When assessing pressure injuries, our results highlight the need to also pay attention to artificial nutrition, continuous deep sedation, and the caregiver's role and gender. Copyright © 2018 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Meesterberends, Esther; Halfens, Ruud J G; Spreeuwenberg, Marieke D; Ambergen, Ton A W; Lohrmann, Christa; Neyens, Jacques C L; Schols, Jos M G A
2013-08-01
To investigate whether the incidence of pressure ulcers in nursing homes in the Netherlands and Germany differs and, if so, to identify resident-related risk factors, nursing-related interventions, and structural factors associated with pressure ulcer development in nursing home residents. A prospective multicenter cohort study. Ten nursing homes in the Netherlands and 11 nursing homes in Germany (around Berlin and Brandenburg). A total of 547 newly admitted nursing home residents, of which 240 were Dutch and 307 were German. Residents had an expected length of stay of 12 weeks or longer. Data were collected for each resident over a 12-week period and included resident characteristics (eg, demographics, medical history, Braden scale scores, nutritional factors), pressure ulcer prevention and treatment characteristics, staffing ratios and other structural nursing home characteristics, and outcome (pressure ulcer development during the study). Data were obtained by trained research assistants. A significantly higher pressure ulcer incidence rate was found for the Dutch nursing homes (33.3%) compared with the German nursing homes (14.3%). Six factors that explain the difference in pressure ulcer incidence rates were identified: dementia, analgesics use, the use of transfer aids, repositioning the residents, the availability of a tissue viability nurse on the ward, and regular internal quality controls in the nursing home. The pressure ulcer incidence was significantly higher in Dutch nursing homes than in German nursing homes. Factors related to residents, nursing care and structure explain this difference in incidence rates. Continuous attention to pressure ulcer care is important for all health care settings and countries, but Dutch nursing homes especially should pay more attention to repositioning residents, the necessity and correct use of transfer aids, the necessity of analgesics use, the tasks of the tissue viability nurse, and the performance of regular internal quality controls. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.
Barba, Francisco J; Esteve, Maria J; Frigola, Ana
2010-09-22
Variations in levels of antioxidant compounds (ascorbic acid, total phenolics, and total carotenoids), total antioxidant capacity, and color changes in a vegetable (tomato, green pepper, green celery, onion, carrot, lemon, and olive oil) beverage treated by high hydrostatic pressure (HHP) were evaluated in this work. The effects of HHP treatment, four different pressures (100, 200, 300, and 400 MPa) and four treatment times for each pressure (from 120 to 540 s) were compared with those of thermal treatment (90-98 °C for 15 and 21 s). High pressure treatment retained significantly more ascorbic acid in the vegetable beverage than thermal treatment. However, no significant changes in total phenolics were observed between HHP treated and thermally processed vegetable beverage and unprocessed beverage. Color changes (a*, b*, L, chroma, h°, and ΔE) were less for pressurized beverage than thermally treated samples compared with unprocessed beverage.
Recent advances in lightweight, filament-wound composite pressure vessel technology
NASA Technical Reports Server (NTRS)
Lark, R. F.
1977-01-01
A review of recent advances is presented for lightweight, high performance composite pressure vessel technology that covers the areas of design concepts, fabrication procedures, applications, and performance of vessels subjected to single cycle burst and cyclic fatigue loading. Filament wound fiber/epoxy composite vessels were made from S glass, graphite, and Kevlar 49 fibers and were equipped with both structural and nonstructural liners. Pressure vessels structural efficiencies were attained which represented weight savings, using different liners, of 40 to 60 percent over all titanium pressure vessels. Significant findings in each area are summarized.
Dassanayaka, Sujith; Brainard, Robert E; Watson, Lewis J; Long, Bethany W; Brittian, Kenneth R; DeMartino, Angelica M; Aird, Allison L; Gumpert, Anna M; Audam, Timothy N; Kilfoil, Peter J; Muthusamy, Senthilkumar; Hamid, Tariq; Prabhu, Sumanth D; Jones, Steven P
2017-05-01
The myocardial response to pressure overload involves coordination of multiple transcriptional, posttranscriptional, and metabolic cues. The previous studies show that one such metabolic cue, O-GlcNAc, is elevated in the pressure-overloaded heart, and the increase in O-GlcNAcylation is required for cardiomyocyte hypertrophy in vitro. Yet, it is not clear whether and how O-GlcNAcylation participates in the hypertrophic response in vivo. Here, we addressed this question using patient samples and a preclinical model of heart failure. Protein O-GlcNAcylation levels were increased in myocardial tissue from heart failure patients compared with normal patients. To test the role of OGT in the heart, we subjected cardiomyocyte-specific, inducibly deficient Ogt (i-cmOgt -/- ) mice and Ogt competent littermate wild-type (WT) mice to transverse aortic constriction. Deletion of cardiomyocyte Ogt significantly decreased O-GlcNAcylation and exacerbated ventricular dysfunction, without producing widespread changes in metabolic transcripts. Although some changes in hypertrophic and fibrotic signaling were noted, there were no histological differences in hypertrophy or fibrosis. We next determined whether significant differences were present in i-cmOgt -/- cardiomyocytes from surgically naïve mice. Interestingly, markers of cardiomyocyte dedifferentiation were elevated in Ogt-deficient cardiomyocytes. Although no significant differences in cardiac dysfunction were apparent after recombination, it is possible that such changes in dedifferentiation markers could reflect a larger phenotypic shift within the Ogt-deficient cardiomyocytes. We conclude that cardiomyocyte Ogt is not required for cardiomyocyte hypertrophy in vivo; however, loss of Ogt may exert subtle phenotypic differences in cardiomyocytes that sensitize the heart to pressure overload-induced ventricular dysfunction.
The effect of prone position on respiratory mechanics during spinal surgery.
Manna, Essam M; Ibraheim, Osama A; Samarkandi, Abdulhamid H; Alotaibi, Wadha M; Elwatidy, Sherif M
2005-10-01
To study the effect of prone position on respiratory mechanics during spine surgery. Prospective study. Elective spine surgery at a university hospital. 12 ASA physical I & II with no coexisting cardiorespiratory disease undergoing cervical or lumbar laminectomy under general anesthesia in prone position. Ten min after induction of general anesthesia and endotracheal intubation, while patients were in supine position, the following measurements were taken using anesthesia delivery unit (Datex Ohmeda type A_Elec, Promma, Sweden): peak airway pressure (Ppeak), peak plataeu pressure (Pplat), peak mean pressure (Pmean) and dynamic lung compliance (DLC). The same measurements were recorded 10 min after placing patients into prone position. At the end of surgery and 5 min after turning the patients supine and before tracheal extubation, the same measurements were again recorded. The results expressed as means +/- sd. One way ANOVA was used for analysis of differences in the data before, during prone position and after turning patients supine at the end of the procedure. For all comparisons p < 0.05 was considered significant. During prone position there was significant reduction in DLC and significant increase in airway pressures. We conclude that turning the patients form supine to prone position during anesthesia for spine surgery caused significant decrease of DLC and significant increase of airway pressure.
Chiu, Yu-Jen; Liao, Wen-Chieh; Wang, Tien-Hsiang; Shih, Yu-Chung; Ma, Hsu; Lin, Chih-Hsun; Wu, Szu-Hsien; Perng, Cherng-Kang
2017-08-01
Despite significant advances in medical care and surgical techniques, pressure sore reconstruction is still prone to elevated rates of complication and recurrence. We conducted a retrospective study to investigate not only complication and recurrence rates following pressure sore reconstruction but also preoperative risk stratification. This study included 181 ulcers underwent flap operations between January 2002 and December 2013 were included in the study. We performed a multivariable logistic regression model, which offers a regression-based method accounting for the within-patient correlation of the success or failure of each flap. The overall complication and recurrence rates for all flaps were 46.4% and 16.0%, respectively, with a mean follow-up period of 55.4 ± 38.0 months. No statistically significant differences of complication and recurrence rates were observed among three different reconstruction methods. In subsequent analysis, albumin ≤3.0 g/dl and paraplegia were significantly associated with higher postoperative complication. The anatomic factor, ischial wound location, significantly trended toward the development of ulcer recurrence. In the fasciocutaneous group, paraplegia had significant correlation to higher complication and recurrence rates. In the musculocutaneous flap group, variables had no significant correlation to complication and recurrence rates. In the free-style perforator group, ischial wound location and malnourished status correlated with significantly higher complication rates; ischial wound location also correlated with significantly higher recurrence rate. Ultimately, our review of a noteworthy cohort with lengthy follow-up helped identify and confirm certain risk factors that can facilitate a more informed and thoughtful pre- and postoperative decision-making process for patients with pressure ulcers. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Wakamoto, Koki; Doi, Shigehiro; Nakashima, Ayumu; Kawai, Toru; Kyuden, Yasufumi; Naito, Takayuki; Asai, Mariko; Takahashi, Shunsuke; Murakami, Masaaki; Masaki, Takao
2018-03-01
This study was performed to investigate the effect of the balloon dilation pressure on the 12-month patency rate in patients with failed arteriovenous fistulas undergoing hemodialysis. In this multicenter, prospective, randomized trial, the 4-mm-diameter YOROI balloon was used for dilation of stenotic lesions. The balloons were inflated to a pressure of 8 atm (low-pressure group) or 30 atm to achieve complete expansion (high-pressure group). The 12-month patency rate after balloon angioplasty was analyzed by the Kaplan-Meier method and log-rank test and/or a Cox proportional hazard model. We also investigated the dilation pressure required to achieve complete expansion in the high-pressure group. In total, 71 patients were enrolled and allocated to either the low-pressure group (n = 34) or the high-pressure group (n = 37). The 12-month patency rates showed no significant difference between the low- and high-pressure groups (47% and 49%, respectively; p = 0.87). In the low-pressure group, the patency rate was not different between patients with complete dilation and residual stenosis (44% and 50%, respectively; p = 0.87). The Cox proportional hazard model revealed that the 12-month patency rate was associated with the stenosis diameter (hazard ratio 0.36; p = 0.001) and the presence of diabetes (hazard ratio 0.33; p = 0.018). Finally, the pressure required to achieve complete dilation was ≤20 atm in 76% of patients and ≤30 atm in 97% of patients. One patient required a dilation pressure of >30 atm. The patency rate does not differ between low-pressure dilation and high-pressure dilation.
Changes in Contact Area in Meniscus Horizontal Cleavage Tears Subjected to Repair and Resection.
Beamer, Brandon S; Walley, Kempland C; Okajima, Stephen; Manoukian, Ohan S; Perez-Viloria, Miguel; DeAngelis, Joseph P; Ramappa, Arun J; Nazarian, Ara
2017-03-01
To assess the changes in tibiofemoral contact pressure and contact area in human knees with a horizontal cleavage tear before and after treatment. Ten human cadaveric knees were tested. Pressure sensors were placed under the medial meniscus and the knees were loaded at twice the body weight for 20 cycles at 0°, 10°, and 20° of flexion. Contact area and pressure were recorded for the intact meniscus, the meniscus with a horizontal cleavage tear, after meniscal repair, after partial meniscectomy (single leaflet), and after subtotal meniscectomy (double leaflet). The presence of a horizontal cleavage tear significantly increased average peak contact pressure and reduced effective average tibiofemoral contact area at all flexion angles tested compared with the intact state (P < .03). There was approximately a 70% increase in contact pressure after creation of the horizontal cleavage tear. Repairing the horizontal cleavage tear restored peak contact pressures and areas to within 15% of baseline, statistically similar to the intact state at all angles tested (P < .05). Partial meniscectomy and subtotal meniscectomy significantly increased average peak contact pressure and reduced average contact area at all degrees of flexion compared with the intact state (P < .05). The presence of a horizontal cleavage tear in the medial meniscus causes a significant reduction in contact area and a significant elevation in contact pressure. These changes may accelerate joint degeneration. A suture-based repair of these horizontal cleavage tears returns the contact area and contact pressure to nearly normal, whereas both partial and subtotal meniscectomy lead to significant reductions in contact area and significant elevations in contact pressure within the knee. Repairing horizontal cleavage tears may lead to improved clinical outcomes by preserving meniscal tissue and the meniscal function. Understanding contact area and peak contact pressure resulting from differing strategies for treating horizontal cleavage tears will allow the surgeon to evaluate the best strategy for treating his or her patients who present with this meniscal pathology. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Viña-Almunia, Jose; Mas-Bargues, Cristina; Borras, Consuelo; Gambini, Juan; El Alami, Marya; Sanz-Ros, Jorge; Peñarrocha, Miguel; Vina, Jose
To analyze, in vitro, the influence of O₂ pressure on the adhesion, proliferation, and osteogenic differentiation of human dental pulp stem cells (DPSC) on β-tricalcium phosphate (β-TCP) scaffold. DPSC, positive for the molecular markers CD133, Oct4, Nestin, Stro-1, and CD34, and negative for CD45, were isolated from extracted third molars. Experiments were started by seeding 200,000 cells on β-TCP cultured under 3% or 21% O₂ pressure. No osteogenic medium was used. Eight different cultures were performed at each time point under each O₂ pressure condition. Cell adhesion, proliferation, and differentiation over the biomaterial were evaluated at 7, 13, 18, and 23 days of culture. Cell adhesion was determined by light microscopy, proliferation by DNA quantification, and osteogenic differentiation by alkaline phosphatase (ALP) activity analysis. DPSC adhered to β-TCP with both O₂ conditions. Cell proliferation was found from day 7 of culture. Higher values were recorded at 3% O₂ in each time point. Statistically significant differences were recorded at 23 days of culture (P = .033). ALP activity was not detectable at 7 days. There was, however, an increase in ALP activity over time in both groups. At 13, 18, and 23 days of culture, higher ALP activity was recorded under 3% O₂ pressure. Statistical differences were found at day 23 (P = .014). DPSC display capacity of adhering to β-TCP under 3% or 21% O₂ pressure conditions. Cell proliferation on β-TCP phosphate is significantly higher at 3% than at 21% O₂ pressure, the most frequently used O₂ tension. β-TCP can itself promote osteogenic differentiation of DPSC and is enhanced under 3% O₂ compared with 21%.
Wang, Yanfei; Yao, Min; Liu, Haibo; Yang, Yuejin; Xie, Junmin; Jia, Xinwei; Pan, Huanjun; Wang, Chunyan
2014-01-01
Balloon release pressure may increase the incidence of no reflow after direct percutaneous coronary intervention (PCI). This randomized controlled study was designed to analyze the correlation between balloon release pressure and no-reflow in patients with acute myocardial infarction (AMI) undergoing direct PCI. There were 156 AMI patients who underwent PCI from January 1, 2010 to December 31, 2012, and were divided into two groups according to the stent inflation pressure: a conventional pressure group and a high pressure group. After PCI, angiography was conducted to assess the thrombolysis in myocardial infarction (TIMI) grade with related artery. Examinations were undertaken on all patients before and after the operation including cardiac enzymes, total cholesterol, low-density lipoprotein, blood glucose, homocysteine , β-thromboglobulin (β-TG), Hamilton depression scale (HAMD) and self-rating anxiety scale (SAS). After interventional therapy, the afore-mentioned parameters in both the conventional pressure group and high pressure group were again analyzed. The results showed that CK-MB, HAMD, SAS were significantly different (P < 0.05) in all patients after PCI, especially the CK-MB in the high pressure group ((25.7 ± 7.6) U/L vs. (76.7 ± 11.8) U/L). CK-MB, HAMD, SAS, and β-TG were comparative before PCI but they were significantly changed (P < 0.05) after intervention. No-reflow phenomenon occurred in 13 patients in the high pressure group, which was significantly higher than in the conventional pressure group (17.11% vs. 6.25%, P < 0.05). In stent implantation, using a pressure less than 1823.4 kPa balloon to release pressure may be the better choice to reduce the occurrence of no-reflow following direct PCI.
Intraabdominal pressure in women during CrossFit exercises and the effect of age and parity.
Gephart, Laura Faye; Doersch, Karen M; Reyes, Michelle; Kuehl, Thomas J; Danford, Jill M
2018-07-01
To determine intraabdominal pressure (IAP) in women during CrossFit and to determine whether parity, age, or CrossFit experience affects IAP during CrossFit exercises, we evaluated 10 women: 5 experienced and active CrossFitters and 5 who were not regularly engaged in CrossFit. A Laborie urodynamics abdominal pressure probe with the Goby wireless system measured IAP during 10 repetitions of 13 different CrossFit exercises. Women had a mean age of 36 years. A significant difference was found between mean peak IAP of the 5 parous vs the 5 nulliparous women ( P = 0.009). Experience with CrossFit did not affect mean peak IAP achieved with exercise. In some exercises, there was a significant change in IAP as participants progressed through repetitions ( P = 0.003 for back squats and 0.04 for sit-ups). Participants achieved IAP values that were markedly higher than those previously published.
Ultra-fast vapor generation by a graphene nano-ratchet: a theoretical and simulation study.
Ding, Hongru; Peng, Guilong; Mo, Shenqiu; Ma, Dengke; Sharshir, Swellam Wafa; Yang, Nuo
2017-12-14
Vapor generation is of prime importance for a broad range of applications: domestic water heating, desalination and wastewater treatment, etc. However, slow and inefficient evaporation limits its development. In this study, a nano-ratchet, a multilayer graphene with cone-shaped nanopores (MGCN), to accelerate vapor generation has been proposed. By performing molecular dynamics simulation, we found that air molecules were spontaneously transported across MGCN and resulted in a remarkable pressure difference, 21 kPa, between the two sides of MGCN. We studied the dependence of the pressure difference on the ambient temperature and geometry of MGCN in detail. Through further analysis of the diffusive transport, we found that pressure difference depended on the competition between ratchet transport and Knudsen diffusion and it was further found that ratchet transport is dominant. The significant pressure difference could lead to a 15-fold or greater enhancement of vapor generation, which shows the wide applications of this nano-ratchet.
Konno, Satoshi; Munakata, Masanori
2017-02-01
We have previously reported that the public employees of Watari town showed significantly greater elevations in both systolic and diastolic blood pressure than the general population 4-8 months after the Great East Japan Earthquake, which occurred on 11 March 2011. To examine whether these differences persisted thereafter, we conducted a follow-up study for both the public employees and the general population of Watari town over 1 year. Among 225 public employees and 1232 individuals from the general population of the town who received consecutive annual health checkups from 2010 to 2012, 89 pairs were matched for age and sex according to a propensity score. The baseline characteristics (predisaster) did not statistically differ between the paired groups. The public employees showed significantly higher systolic and diastolic blood pressure in 2011 (postdisaster) compared with the general population (129.8 ± 14.0/78.0 ± 11.7 vs. 117.0 ± 14.4/71.6 ± 11.4 mm Hg, P < 0.001 for both). Furthermore, the systolic blood pressure of the public employees remained significantly higher than that of the general population in 2012 (125.3 ± 16.0 vs. 119.9 ± 15.5 mm Hg, P = 0.023). Prolonged blood pressure elevation among the public employees was observed for more than 1 year after the disaster, suggesting a need for close blood pressure monitoring of public employees engaged in long-term disaster relief operations. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Plantar Pressures After Nonoperative Treatment for Clubfoot: Intermediate Follow-up at Age 5 Years.
Jeans, Kelly A; Erdman, Ashley L; Karol, Lori A
2017-01-01
Worldwide, a nonoperative approach in the treatment of idiopathic clubfoot has been taken in an attempt to reduce the incidence of surgical outcomes. Although both the Ponseti casting (Ponseti) and the French physiotherapy (PT) methods have shown gait and pedobarograph differences at age 2 years, improved gait results have been reported by age 5 years. The purpose of this study was to assess plantar pressures in feet treated with the Ponseti versus the PT methods at this intermediate stage. Clubfoot patients treated nonoperatively (Ponseti or PT) underwent pedobarograph data collection at age 5 years. The foot was subdivided into the medial/lateral hindfoot, midfoot, and forefoot regions. Variables included Peak Pressure, Maximum Force, Contact Area%, Contact Time%, Pressure Time Integral, the hindfoot-forefoot angle, and displacement of the center of pressure (COP) line. Twenty controls were used for comparison. Pedobarograph data from 164 patients (238 feet; 122 Ponseti and 116 PT) showed no significant differences between the Ponseti and the PT feet, except the PT feet had a significantly less medial movement of the COP than the Ponseti feet (P=0.0379). Compared with controls, both groups had decreased plantar pressures in the hindfoot and first metatarsal regions, whereas the midfoot and lateral forefoot experienced significant increases compared with controls. This lateralization was also reflected in the hindfoot-forefoot angle and the COP. Feet that remain nonoperative and avoid surgical intervention are considered a good clinical result. However, pedobarograph results indicate mild residual deformity in these feet despite clinically successful outcomes. Level II-therapeutic.
Weppner, Justin
2013-08-01
The military medical community has promoted use of Foley catheter balloon tamponade in the initial management of vascular injury owing to neck or maxillofacial trauma. The aim of the study was to compare outcomes with Foley catheter tamponade with those obtained with traditional use of external pressure. This retrospective cohort study evaluated all cases of persistent bleeding caused by penetrating neck or maxillofacial trauma received at one forward aid station between December 2009 and October 2011. Cohorts included those who were treated with Foley catheter tamponade and those managed with external pressure. Which treatment option was applied depended solely on the availability of Foley catheters at the time. The effectiveness of each technique in controlling initial and delayed hemorrhage is described, and the impact on mortality is analyzed using the Student's t test and Fisher's exact test. Seventy-seven subjects met the inclusion criteria with 42 subjects in the Foley group and 35 subjects in the external pressure group. A statistically significant difference was found between the groups regarding delayed failure, experienced by three patients (7%) in the Foley group and nine patients (26%) in the external pressure group (p < 0.05). The difference in mortality, 5% (two patients) in the Foley tamponade group and 23% (eight patients) in the external pressure group, was statistically significant (p < 0.05). For penetrating neck and maxillofacial injuries in a combat environment, Foley catheter balloon tamponade significantly reduced mortality when compared with direct pressure techniques through its effect on preventing delayed bleeding.
Jawed, Shireen; Zia, Sadaf; Tariq, Sundus
2017-08-01
To determine the frequency of different blood groups among female medical students and to find the association of blood groups and body mass index with blood pressure. This cross-sectional study was performed at the University Medical and Dental College, Faisalabad, Pakistan, from March to April 2016, and comprised female medical students. Participants were divided into groups on the basis of their ABO blood groups and on body mass index criteria. Blood groups were determined by simple conventional slide method. Blood pressure was estimated by manual auscultatory technique with a mercury sphygmomanometer. Data was analysed usingSPSS20. There were 145 students with an overall mean age of18.4±0.75 years (range: 17-23 years). Blood group B was the predominant group 65(44.8%). Besides, 130(89.6%) subjects were rhesus positive and 23(53%) subjects of blood group O were pre-hypertensive. Multiple regression analysis indicated significant positive association of blood group O with both systolic and diastolic blood pressure (p=0.002, 0.001). However, subsequent logistic regression showed significant association only with diastolic blood pressure (p=0.001). Relative risk of pre-hypertension for obese (p=0.001) was greater than non-obese subjects. Body mass index was significantly associated with both systolic and diastolic blood pressure (p=0.004, 0.042). Blood group B was the most common blood group. Blood group O was associated with diastolic pre-hypertension, while body mass index was associated with both systolic and diastolic pre-hypertension.
Neonatal Treatment with Antiserum to Prolactin Lowers Blood Pressure in Rats
NASA Astrophysics Data System (ADS)
Mills, David E.; Buckman, Maire T.; Peake, Glenn T.
1982-07-01
Prolactin administration reportedly increases blood pressure in rats and rabbits. To study the effects of prolactiin deficiency on blood pressure, rats were given saline, normal rabbit serum, or rabbit antiserum to rat prolactin on postnatal days 2 to 5. Both males and females given antiserum had significantly lower blood pressure at 14 weeks than rats given saline or normal rabbit serum. Blood pressure differences between females given antiserum and females given saline disappeared during and following pregnancy. The antiserum also lowered the concentration of prolactin in plasma 49 percent in males and decreased the prolactin response to ether stress in both sexes. These results suggest that endogenous prolactin is involved in blood pressure regulation.
Tourniquet pressures: strap width and tensioning system widths.
Wall, Piper L; Coughlin, Ohmar; Rometti, Mary; Birkholz, Sarah; Gildemaster, Yvonne; Grulke, Lisa; Sahr, Sheryl; Buising, Charisse M
2014-01-01
Pressure distribution over tourniquet width is a determinant of pressure needed for arterial occlusion. Different width tensioning systems could result in arterial occlusion pressure differences among nonelastic strap designs of equal width. Ratcheting Medical Tourniquets (RMTs; m2 inc., http://www.ratcheting buckles.com) with a 1.9 cm-wide (Tactical RMT) or 2.3 cm-wide (Mass Casualty RMT) ladder were directly compared (16 recipients, 16 thighs and 16 upper arms for each tourniquetx2). Then, RMTs were retrospectively compared with the windlass Combat Application Tourniquet (C-A-T ["CAT"], http://combattourniquet.com) with a 2.5 cm-wide internal tensioning strap. Pressure was measured with an air-filled No. 1 neonatal blood pressure cuff under each 3.8 cm-wide tourniquet. RMT circumferential pressure distribution was not uniform. Tactical RMT pressures were not higher, and there were no differences between the RMTs in the effectiveness, ease of use ("97% easy"), or discomfort. However, a difference did occur regarding tooth skipping of the pawl during ratchet advancement: it occurred in 1 of 64 Tactical RMT applications versus 27 of 64 Mass Casualty RMT applications. CAT and RMT occlusion pressures were frequently over 300 mmHg. RMT arm occlusion pressures (175-397 mmHg), however, were lower than RMT thigh occlusion pressures (197-562 mmHg). RMT effectiveness was better with 99% reached occlusion and 1% lost occlusion over 1 minute versus the CAT with 95% reached occlusion and 28% lost occlusion over 1 minute. RMT muscle tension changes (up to 232 mmHg) and pressure losses over 1 minute (24±11 mmHg arm under strap to 40±12 mmHg thigh under ladder) suggest more occlusion losses may have occurred if tourniquet duration was extended. The narrower tensioning system Tactical RMT has better performance characteristics than the Mass Casualty RMT. The 3.8 cm-wide RMTs have some pressure and effectiveness similarities and differences compared with the CAT. Clinically significant pressure changes occur under nonelastic strap tourniquets with muscle tension changes and over time periods as short as 1 minute. An examination of pressure and occlusion changes beyond 1 minute would be of interest. 2014.
Incidence of swallowing during exercise in horses with dorsal displacement of the soft palate.
Pigott, J H; Ducharme, N G; Mitchell, L M; Soderholm, L V; Cheetham, J
2010-11-01
The relationship between dorsal displacement of the soft palate (DDSP) and swallowing is unclear. To quantify the relationship between DDSP and swallowing in horses at exercise. The frequency of swallowing increases immediately prior to DDSP in horses at exercise. Videoendoscopic and upper airway pressure data were collated from horses with a definitive diagnosis of DDSP at exercise. Horses with no upper airway abnormalities were matched by age, breed and sex and used as controls. Sixty-nine horses were identified with a definitive diagnosis of DDSP during the study interval. Airway pressure data were available for 42 horses. The majority of horses displaced at high exercising speeds while accelerating; a smaller number displaced during deceleration after peak speed had been reached. Horses swallowed significantly more frequently in the 1 min immediately preceding DDSP than in the control horses at equivalent speeds. DDSP at exercise results in a significant increase in tracheal expiratory pressure, a significant decrease in pharyngeal expiratory pressure and a significantly less negative pharyngeal inspiratory pressure compared to matched controls and compared to the pressures during the 1 min interval prior to DDSP. There was no significant difference between any measure of airway pressure before or after a swallow when examined at each time interval in the DDSP population. The frequency of swallowing decreases with increasing speed in normal horses. In contrast, the frequency of swallowing increases immediately prior to onset of DDSP. This is not a result of pharyngeal and tracheal pressure changes. The increased frequency of swallowing observed prior to DDSP may be related to the aetiology of the disease. © 2010 EVJ Ltd.
Lee, I-Te; Chen, Chen-Huan; Wang, Jun-Sing; Fu, Chia-Po; Lee, Wen-Jane; Liang, Kae-Woei; Lin, Shih-Yi; Sheu, Wayne Huey-Herng
2018-01-01
Arterial stiffening blunts postprandial vasodilatation. We hypothesized that brain-derived neurotrophic factor (BDNF) may modulate postprandial central pulse pressure, a surrogate marker for arterial stiffening. A total of 82 non-diabetic subjects received a 75-g oral glucose tolerance test (OGTT) after overnight fasting. Serum BDNF concentrations were determined at 0, 30, and 120min to calculate the area under the curve (AUC). Brachial and central blood pressures were measured using a noninvasive central blood pressure monitor before blood withdrawals at 0 and 120min. With the median AUC of BDNF of 45(ng/ml)∗h as the cutoff value, the central pulse pressure after glucose intake was significantly higher in the subjects with a low BDNF than in those with a high BDNF (63±16 vs. 53±11mmHg, P=0.003), while the brachial pulse pressure was not significantly different between the 2 groups (P=0.099). In a multivariate linear regression model, a lower AUC of BDNF was an independent predictor of a higher central pulse pressure after oral glucose intake (linear regression coefficient-0.202, 95% confidence interval-0.340 to -0.065, P=0.004). After oral glucose challenge, a lower serum BDNF response is significantly associated with a higher central pulse pressure. Copyright © 2017 Elsevier B.V. All rights reserved.
Kaushik, Neelima; Kaur, Barjinder P; Rao, P Srinivasa
2014-10-01
This study attempts to report the effect of high pressure processing (100, 200 and 300 MPa for 5, 10 and 15 min at 27 ± 2 ℃) on quality and shelf life extension of 'Bombai' variety peeled litchi fruits during refrigerated storage (5 ℃). High pressure processing significantly increased total colour difference, browning index, drip loss and total soluble solids, whereas pH decreased after processing. Also, ascorbic acid content significantly decreased after high pressure processing and retention of 83.5% was observed. Texture profile analysis showed that pressurization significantly affected firmness and increased cohesiveness, gumminess, springiness and chewiness of litchi fruits. Pressure-induced firming effect was observed at 100 and 200 MPa pressure. A maximum of 3.29, 3.24 and 3.77 log10 cycles reduction in aerobic mesophiles, yeast & mold and psychrotrophs count, respectively, was achieved after pressurization of 300 MPa for 10 and 15 min treatments. During storage, samples treated at 300 MPa for 10 and 15 min showed relatively minimal changes in physico-chemical attributes, textural parameters and maintained lower viable microbial counts. Treatments at 300 MPa for 10 min and 15 min were found to enhance the shelf life of litchi fruits up to 32 days as compared to 12 days of untreated during refrigerated storage (5 ℃). © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Effect of pressure difference on the quality of titanium casting.
Watanabe, I; Watkins, J H; Nakajima, H; Atsuta, M; Okabe, T
1997-03-01
In casting titanium using a two-compartment casting machine, Herø et al. (1993) reported that the pressure difference between the melting chamber and the mold chamber affected the soundness of the castings. This study tested the hypothesis that differences in pressure produce castings with various amounts of porosity and different mechanical properties values. Plastic dumbbell-shaped patterns were invested with an alumina-based, phosphate-bonded investment material. Both chambers of the casting machine were evacuated to 6 x 10(-2) torr; the argon pressure difference was then adjusted to either 50, 150, 300, or 450 torr. The porosity of the cast specimens was determined by x-ray radiography and quantitative image analysis. Tensile strength and elongation were measured by means of a universal testing machine at a strain rate of 1.7 x 10(-4)/s. The fractured surfaces were examined by SEM. Changes in Vickers hardness with depth from the cast surface were measured on polished cross-sections of the specimens. Raising the argon pressure difference to 300 and 450 torr caused a significant increase in internal porosity and a resultant decrease in the engineering tensile strength and elongation. The highest tensile strength (approximately 540 MPa), elongation (approximately 10%), bulk hardness (HV50g 209), and lowest porosity level (approximately 0.8%) occurred in the specimens cast at 150 torr. Turbulence of the metal during casting was thought to be responsible for the increase in porosity levels with the increase in argon pressure difference. By choosing an argon pressure difference (around 150 torr) suitable for this geometry, we could produce castings which have adequate mechanical properties and low porosity levels.
Charmoy, Alexia; Würzner, Grégoire; Ruffieux, Christiane; Hasler, Christopher; Cachat, François; Waeber, Bernard; Burnier, Michel
2007-10-01
Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.
Effect of cocoa on blood pressure.
Ried, Karin; Fakler, Peter; Stocks, Nigel P
2017-04-25
High blood pressure is an important risk factor for cardiovascular disease, contributing to about 50% of cardiovascular events worldwide and 37% of cardiovascular-related deaths in Western populations. Epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. Flavanols found in cocoa have been shown to increase the formation of endothelial nitric oxide which promotes vasodilation and therefore blood pressure reduction. Here we update previous meta-analyses on the effect of cocoa on blood pressure. To assess the effects on blood pressure of chocolate or cocoa products versus low-flavanol products or placebo in adults with or without hypertension when consumed for two weeks or longer. This is an updated version of the review initially published in 2012. In this updated version, we searched the following electronic databases from inception to November 2016: Cochrane Hypertension Group Specialised Register, CENTRAL, MEDLINE and Embase. We also searched international trial registries, and the reference lists of review articles and included trials. Randomised controlled trials (RCTs) investigating the effects of chocolate or cocoa products on systolic and diastolic blood pressure in adults for a minimum of two weeks duration. Two review authors independently extracted data and assessed the risks of bias in each trial. We conducted random-effects meta-analyses on the included studies using Review Manager 5. We explored heterogeneity with subgroup analyses by baseline blood pressure, flavanol content of control group, blinding, age and duration. Sensitivity analyses explored the influence of unusual study design. Thirty-five trials (including 40 treatment comparisons) met the inclusion criteria. Of these, we added 17 trials (20 treatment comparisons) to the 18 trials (20 treatment comparisons) in the previous version of this updated review.Trials provided participants with 30 to 1218 mg of flavanols (mean = 670 mg) in 1.4 to 105 grams of cocoa products per day in the active intervention group. The control group received either a flavanol-free product (n = 26 treatment comparisons) or a low-flavanol-containing cocoa powder (range 6.4 to 88 mg flavanols (mean = 55 mg, 13 treatment comparisons; 259 mg, 1 trial).Meta-analyses of the 40 treatment comparisons involving 1804 mainly healthy participants revealed a small but statistically significant blood pressure-reducing effect of flavanol-rich cocoa products compared with control in trials of two to 18 weeks duration (mean nine weeks):Mean difference systolic blood pressure (SBP) (95% confidence interval (CI): -1.76 (-3.09 to -0.43) mmHg, P = 0.009, n = 40 treatment comparisons, 1804 participants;Mean difference diastolic blood pressure (DBP) (95% CI): -1.76 (-2.57 to -0.94) mmHg, P < 0.001, n = 39 treatment comparisons, 1772 participants.Baseline blood pressure may play a role in the effect of cocoa on blood pressure. While systolic blood pressure was reduced significantly by 4 mmHg in hypertensive people (n = 9 treatment comparisons, 401 participants), and tended to be lowered in prehypertensive people (n= 8 treatment comparisons, 340 participants), there was no significant difference in normotensive people (n = 23 treatment comparisons, 1063 participants); however, the test for subgroup differences was of borderline significance (P = 0.08; I 2 = 60%), requiring further research to confirm the findings.Subgroup meta-analysis by blinding suggested a trend towards greater blood pressure reduction in unblinded trials compared to double-blinded trials, albeit statistically not significant. Further research is needed to confirm whether participant expectation may influence blood pressure results. Subgroup analysis by type of control (flavanol-free versus low-flavanol control) did not reveal a significant difference.Whether the age of participants plays a role in the effect of cocoa on blood pressure, with younger participants responding with greater blood pressure reduction, needs to be further investigated.Sensitivity analysis excluding trials with authors employed by trials sponsoring industry (33 trials, 1482 participants) revealed a small reduction in effect size, indicating some reporting bias.Due to the remaining heterogeneity, which we could not explain in terms of blinding, flavanol content of the control groups, age of participants, or study duration, we downgraded the quality of the evidence from high to moderate.Results of subgroup analyses should be interpreted with caution and need to be confirmed or refuted in trials using direct randomised comparisons.Generally, cocoa products were highly tolerable, with adverse effects including gastrointestinal complaints and nausea being reported by 1% of participants in the active cocoa intervention group and 0.4% of participants in the control groups (moderate-quality evidence). This review provides moderate-quality evidence that flavanol-rich chocolate and cocoa products cause a small (2 mmHg) blood pressure-lowering effect in mainly healthy adults in the short term.These findings are limited by the heterogeneity between trials, which could not be explained by prespecified subgroup analyses, including blinding, flavanol content of the control groups, age of participants, or study duration. However, baseline blood pressure may play a role in the effect of cocoa on blood pressure; subgroup analysis of trials with (pre)hypertensive participants revealed a greater blood pressure-reducing effect of cocoa compared to normotensive participants with borderline significance.Long-term trials investigating the effect of cocoa on clinical outcomes are also needed to assess whether cocoa has an effect on cardiovascular events and to assess potential adverse effects associated with chronic ingestion of cocoa products.
Seker, Ayse; Demirci, Hakan; Ocakoglu, Gokhan; Aydin, Ufuk; Ucar, Hakan; Yildiz, Gursel; Yaman, Ozen
2017-10-01
We aimed to analyze the difference in 24-h blood pressure values during Ramadan of fasting and nonfasting individuals with no previous history of hypertension. This study was planned as a multicenter research study in the cities of Izmit, Zonguldak, Sivas, and Adana. The percentage changes in the blood pressure of the patients were calculated from their blood pressure measurements at 0 h while they were resting. A Food Frequency Questionnaire was filled out by all participants. Forty patients were included in the fasting group and 55 patients were included in the nonfasting group in the study. There was a difference between the two groups in percent changes of systolic measurements performed at the 4th (5% difference and P=0.020), 13th (6% difference and P=0.015), 14th (10% difference and P=0.017), 18th (9% difference and P=0.027), 19th (9% difference and P=0.020), and 20th (6% difference and P=0.014) hours with respect to the baseline measurement at the 0 h. There was a difference between the fasting and nonfasting groups in the Fasting Food Questionnaire results. Meat consumption was significantly higher in the fasting group. A systolic blood pressure increase in fasting patients was observed in measurements at 18:00, 19:00, and 20:00 h. We believe that an increase of more than 10% in blood pressure at the time of iftar is an important result of our study in terms of the meal preferences of the individuals under risk.
Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.
Johnson, Karin Gardner; Johnson, Douglas Clark
2015-01-01
Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features.
Şenay, Hasan; Sıvacı, Remziye; Kokulu, Serdar; Koca, Buğra; Bakı, Elif Doğan; Ela, Yüksel
2016-08-01
The aim of this present study is to compare the effect of pressure-controlled ventilation and volume-controlled ventilation on pulmonary mechanics and inflammatory markers in prone position. The study included 41 patients undergoing to vertebrae surgery. The patients were randomized into two groups: Group 1 received volume-controlled ventilation, while group 2 received pressure-controlled ventilation. The demographic data, pulmonary mechanics, the inflammatory marker levels just after the induction of anesthetics, at the 6th and 12th hours, and gas analysis from arterial blood samples taken at the beginning and the 30th minute were recorded. The inflammatory marker levels increased in both groups, without any significant difference among groups. Peak inspiratory pressure level was higher in the volume-controlled ventilation group. This study revealed that there is no difference regarding inflammatory marker levels between volume- and pressure-controlled ventilation.
Sadler, Ryan A; Hall, Natalie H; Kass, Philip H; Citino, Scott B
2013-12-01
Two indirect blood pressure measurement techniques, Doppler (DOP) sphygmomanometry and oscillometry, applied at the ventral coccygeal artery were compared with simultaneous direct blood pressure measurements at the dorsal pedal artery in 10 anesthetized, captive cheetahs (Acinonyx jubatus). The DOP method was moderately accurate, with relatively little bias (mean difference 3.8 mmHg) and 88.6% of the DOP systolic arterial pressure measurements being within 10 mmHg of the direct systolic arterial measurement. With the oscillometric (OM) method, 89.2% of the mean arterial pressure measurements were within 10 mmHg of the direct measurement and had the least bias (mean difference 2.3 mmHg), 80.7% of the systolic measurements were within 10 mmHg of the direct measurement and had the second least bias (mean difference 2.3 mmHg), and 59% of the diastolic measurements were within 10 mmHg of the direct measurement and had significant bias (mean difference 7.3 mmHg). However, DOP showed relatively poor precision (SD 11.2 mmHg) compared with OM systolic (SD 8.0 mmHg), diastolic (SD 8.6 mmHg), and mean (SD 5.7 mmHg). Both techniques showed a linear relationship with the direct technique measurements over a wide range of blood pressures. The DOP method tended to underestimate systolic measurements below 160 mmHg and overestimate systolic measurements above 160 mmHg. The OM method tended to underestimate mean pressures below 160 mm Hg, overestimate mean pressures above 160 mmHg, underestimate systolic pressures below 170 mmHg, overestimate systolic pressures above 170 mmHg, and underestimate diastolic pressures throughout the measured blood pressure range. Indirect blood pressure measurement using the ventral coccygeal artery, particularly when using an OM device for mean and systolic arterial pressure, may be useful in the clinical assessment of cheetahs when monitoring trends over time, but caution should be taken when interpreting individual values.
Halawa, Mohammed R; Eid, Yara M; El-Hilaly, Rana A; Abdelsalam, Mona M; Amer, Amr H
Foot disease is a common complication of type 2 diabetes that can have tragic consequences. Abnormal plantar pressures are considered to play a major role in the pathologies of neuropathic ulcers in the diabetic foot. To examine Relationship of Planter Pressure and Glycemic Control in Type 2 Diabetic Patients with and without Neuropathy. The study was conducted on 50 type 2 diabetic patients and 30 healthy volunteers. BMI calculation, disease duration, Hemoglobin A1c and presence of neuropathy (by history, foot examination and DN4 questionnaire) were recorded. Plantar pressure was recorded for all patients using the Mat-scan (Tekscan, Inc.vers. 6.34 Boston USA) in static conditions (standing) and dynamic conditions (taking a step on the Mat-scan). Plantar pressures (kPa) were determined at the five metatarsal areas, mid foot area, medial and lateral heel areas and medial three toes. Static and dynamic plantar pressures in both right and left feet were significantly higher in diabetic with neuropathy group than in control group in measured areas (P<0.05). Static and dynamic pressures in right and left feet were significantly higher in diabetic with neuropathy group than in diabetic without neuropathy group in measured areas (P<0.05). On comparison between controls and diabetic without neuropathy group there was a significant difference in plantar pressures especially in metatarsal areas (P<0.05). No significant correlations were present between the studied variables age, disease duration, BMI and HbA1c and plantar pressures in all studied areas. Persons with diabetic neuropathy have elevated peak plantar pressure (PPP) compared to patients without neuropathy and control group. HbA1c% as a surrogate for glycemic control had no direct impact on peak planter pressure, yet it indirectly impacts neuropathy evolution through out disease duration eventually leading to the drastic planter pressure and gait biomechanics changes. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Comparison of forward (ear-canal) and reverse (round-window) sound stimulation of the cochlea.
Stieger, Christof; Rosowski, John J; Nakajima, Hideko Heidi
2013-07-01
The cochlea is normally driven with "forward" stimulation, in which sound is introduced to the ear canal. Alternatively, the cochlea can be stimulated at the round window (RW) using an actuator. During RW "reverse" stimulation, the acoustic flow starting at the RW does not necessarily take the same path as during forward stimulation. To understand the differences between forward and reverse stimulation, we measured ear-canal pressure, stapes velocity, RW velocity, and intracochlear pressures in scala vestibuli (SV) and scala tympani (ST) of fresh human temporal bones. During forward stimulation, the cochlear drive (differential pressure across the partition) results from the large difference in magnitude between the pressures of SV and ST, which occurs due to the high compliance of the RW. During reverse stimulation, the relatively high impedance of the middle ear causes the pressures of SV and ST to have similar magnitudes, and the differential pressure results primarily from the difference in phase of the pressures. Furthermore, the sound path differs between forward and reverse stimulation, such that motion through a third window is more significant during reverse stimulation. Additionally, we determined that although stapes velocity is a good estimate of cochlear drive during forward stimulation, it is not a good measure during reverse stimulation. This article is part of a special issue entitled "MEMRO 2012". Copyright © 2012 Elsevier B.V. All rights reserved.
Huang, Ling; Xie, Chen; Zhang, Lifeng; Meng, Liying; Li, Guizheng; Li, Yang; Huang, Bing; Pan, Linghui; Tang, Zhanhong
2017-01-01
To discuss the influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge, and to provide some reference for the clinical work. The experiment was carried out on the model of the glass tube, which was divided into three parts. Each part of the experiment was divided into normal pressure group and high pressure group according to the different inflation pressure target value. The endotracheal tube cuff pressure was determined intermittently by using the transparent tracheal models which had a static diameter of 2 cm. The target press value of normal pressure group was 32 cmH 2 O (1 cmH 2 O = 0.098 kPa) while that of high pressure group was 40 cmH 2 O. The handheld pressure gauge was connected with the indicated cuff through a tee joint, and the pressure in the cuff in both groups was determined. The pressure loss caused by intermittent measurement of the two groups was compared. By switching the tee joint, the pressure loss through the gauge self-structure and the pressure loss when connecting and disconnecting the indicated cuff were determined to analyze the causes of pressure loss caused by intermittent measurement of pressure gauge. The pressure loss caused by intermittent measurement of high pressure group was significantly higher than that of normal pressure group (cmH 2 O: 15.10±0.43 vs. 10.19±0.45) with statistical significance (t = -24.875, P = 0.000). The pressure loss through the gauge self-structure of high pressure group was also significantly higher than that of normal pressure group (cmH 2 O: 13.91±0.48 vs. 8.77±0.53), which showed a statistics significance (t = -22.854, P = 0.000). The pressure loss when connecting and disconnecting the indicated cuff of the normal pressure and high pressure groups were (1.33±0.49) cmH 2 O and (1.23±0.55) cmH 2 O, respectively, without statistics significance (t = 0.445, P = 0.662). It was figured that the total pressure loss caused by intermittent measurement of the endotracheal intubation cuff was approximately equal to the value of the pressure loss caused by the pressure gauge self-structure and the pressure loss when the indicated cuff was connected and disconnected [normal pressure group: (10.19±0.45) cmH 2 O ≍ (8.77±0.53) cmH 2 O + (1.33±0.49) cmH 2 O, high pressure group: (15.10±0.43) cmH 2 O ≍ (13.91±0.48) cmH 2 O + (1.23±0.55) cmH 2 O]. The intermittently monitoring on endotracheal tube cuff pressure is the main cause of the pressure loss. The total pressure loss consists of the pressure leak from the cuff to the gauge and the pressure leak when connecting and disconnecting the gauge and the indicated cuff during each test. When the pressure in the cuff is increased, it will cause more pressure loss.
McMonnies, Charles W
2016-05-01
This review examines some of the biomechanical consequences associated with the opposing intraocular and intracranial forces. These forces compress the lamina cribrosa and are a potential source of glaucomatous pathology. A difference between them creates a displacement force on the lamina cribrosa. Increasing intraocular pressure and/or decreasing intracranial pressure will increase the trans-lamina cribrosa pressure difference and the risk of its posterior displacement, canal expansion and the formation of pathological cupping. Both intraocular pressure and intracranial pressure can be elevated during a Valsalva manoeuvre with associated increases in both anterior and posterior lamina cribrosa loading as well as its compression. Any resulting thinning of or damage to the lamina cribrosa and/or retinal ganglion cell axons and/or astrocyte and glial cells attached to the matrix of the lamina cribrosa and/or reduction in blood flow to the lamina cribrosa may contribute to glaucomatous neuropathy. Thinning of the lamina cribrosa reduces its stiffness and increases the risk of its posterior displacement. Optic nerve head posterior displacement warrants medical or surgical lowering of intraocular pressure; however, compared to intraocular pressure, the trans-lamina cribrosa pressure difference may be more important in pressure-related pathology of the optic nerve head region. Similarly important could be increased compression loading of the lamina cribrosa. Reducing participation in activities which elevate intraocular and intracranial pressure will decrease lamina cribrosa compression exposure and may contribute to glaucoma management and may have prognostic significance for glaucoma suspects. © 2016 The Authors. Clinical and Experimental Optometry © 2016 Optometry Australia.
Weight effect of saline accumulation in surgical drapes.
Wiggins, Michael N; Thostenson, Jeff D
2007-10-01
Positive vitreal pressure during phacoemulsification is a known risk factor for posterior capsule rupture. Knowledge of modifiable causes of positive vitreal pressure is imperative to aid in its management intraoperatively. The aim of our study was to determine whether the weight from the accumulation of a large volume of saline in the surgical drapes could have an effect on intraocular pressure in patients. Such an effect could indicate a source of posterior vitreal pressure in patients undergoing prolonged phacoemulsification. In 23 adult patients undergoing phacoemulsification at the Jones Eye Institute at the University of Arkansas for Medical Sciences, intraocular pressure readings were taken before and after the addition of 500 cc of saline to the surgical drapes and taken again after removal of the saline. Statistically significant differences in intraocular pressure were found between the baseline measurement, the measurement with saline, and the measurement after saline removal. No differences in the rise in intraocular pressure were found according to age, race, sex, or which eye was tested. Accumulation of a large volume of saline in surgical drapes has a modest effect on intraocular pressure. This may indicate a contributing cause of posterior vitreal pressure during prolonged phacoemulsification.
Aggarwal, Rahul; Mirzan, Haares; Chiu, Nicholas; Steinkamp, Jackson
2018-02-26
ACCORD and SPRINT are the best randomized controlled trial data evaluating the effects of blood pressure targets below 140 mmHg. These trials had contradictory results regarding the benefits of intensive antihypertensive therapy. We investigate if this discordance was driven by SPRINT's inclusion of Heart Failure in its primary outcome, as this is a parameter not included in ACCORD's original primary outcome. This analysis helps to resolve a significant area of contention. Individual patient data from 4733 participants in ACCORD were analyzed from time of randomization. All participants were diabetic and at increased cardiovascular risk. Participants were assigned to their original intervention, a standard blood pressure target of less than 140 mmHg or an intensive target of less than 120 mmHg. Primary composite outcome was defined as in SPRINT: a composite of first occurrence of myocardial infarction, stroke, heart failure, death from cardiovascular causes, and other acute coronary syndromes. Primary outcome was not significantly different between standard and intensive groups [HR: 0.89; 95% CI: (0.76-1.03); p = 0.108]. The primary composite outcome occurred in 370 participants in the standard group (15.6%) and 324 participants in the intensive group (13.7%), with an event rate of 3.38% per year for the standard group and 3.01% per year for the intensive group. Differing results between ACCORD and SPRINT are not attributable to ACCORD's exclusion of Heart Failure from its original primary outcome measurement. No significant differences in primary outcome were observed between intensive and standard blood pressure groups in the ACCORD patients under the SPRINT primary outcome definition. Caution should be taken in extrapolating the intensive blood pressure control benefits of SPRINT to the diabetic population.
Plantar pressure with and without custom insoles in patients with common foot complaints.
Stolwijk, Niki M; Louwerens, Jan Willem K; Nienhuis, Bart; Duysens, Jacques; Keijsers, Noël L W
2011-01-01
Although many patients with foot complaints receive customized insoles, the choice for an insole design can vary largely among foot experts. To investigate the variety of insole designs used in daily practice, the insole design and its effect on plantar pressure distribution were investigated in a large group of patients. Mean, peak, and pressure-time-integral per sensor for 204 subjects with common foot complaints for walking with and without insoles was measured with the footscan® insole system (RSscan International). Each insole was scanned twice (precision3D), after which the insole height along the longitudinal and transversal cross section was calculated. Subjects were assigned to subgroups based on complaint and medial arch height. Data were analyzed for the total group and for the separate subgroups (forefoot or heel pain group and flat, normal or high medial arch group). The mean pressure significantly decreased under the metatarsal heads II-V and the calcaneus and significantly increased under the metatarsal bones and the lateral foot (p<0.0045) due to the insoles. However, similar redistribution patterns were found for the different foot complaints and arch heights. There was a slight difference in insole design between the subgroups; the heel cup was significantly higher and the midfoot support lower for the heel pain group compared to the forefoot pain group. The midfoot support was lowest in the flat arch group compared to the high and normal arch group (p<0.05). Although the insole shape was specific for the kind of foot complaint and arch height, the differences in shape were very small and the plantar pressure redistribution was similar for all groups. This study indicates that it might be sufficient to create basic insoles for particular patient groups.
Peck, Robert N; Smart, Luke R; Beier, Rita; Liwa, Anthony C; Grosskurth, Heiner; Fitzgerald, Daniel W; Schmidt, Bernhard M W
2013-09-26
Among African-Americans adults, arterial hypertension is both more prevalent and associated with more complications than among white adults. Hypertension is also epidemic among black adults in sub-Saharan Africa. The treatment of hypertension among black adults may be complicated by lesser response to certain classes of anti-hypertensive agents. We systematically searched literature for clinical trials of ACE-inhibitors among hypertensive adults comparing blood pressure response between whites and blacks. Meta-analysis was performed to determine the difference in systolic and diastolic blood pressure response. Further analysis including meta-regressions, funnel plots, and one-study-removed analyses were performed to investigate possible sources of heterogeneity or bias. In a meta-analysis of 13 trials providing 17 different patient groups for evaluation, black race was associated with a lesser reduction in systolic (mean difference: 4.6 mmHg (95% CI 3.5-5.7)) and diastolic (mean difference: 2.8 mmHg (95% CI 2.2-3.5)) blood pressure response to ACE-inhibitors, with little heterogeneity. Meta-regression revealed only ACE-inhibitor dosage as a significant source of heterogeneity. There was little evidence of publication bias. Black race is consistently associated with a clinically significant lesser reduction in both systolic and diastolic blood pressure to ACE-inhibitor therapy in clinical trials in the USA and Europe. In black adults requiring monotherapy for uncomplicated hypertension, drugs other than ACE-inhibitors may be preferred, though the proven benefits of ACE-inhibitors in some sub-groups and the large overlap of response between blacks and whites must be remembered. These data are particularly important for interpretation of clinical drug trials for hypertensive black adults in sub-Saharan Africa and for the development of treatment recommendations in this population.
Zheng, Dingchang; Pan, Fan; Murray, Alan
2013-10-01
The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P < 0.01), manual DBP was 1.5 mmHg higher (P < 0.01), manual PP was 4.2 mmHg lower (P < 0.001), automated DBP was 6.7 mmHg higher (P < 0.001) and automatic PP was 7.5 mmHg lower (P < 0.001). There was no statistically significant difference for any automated BPs between fast and standard cuff inflation. The statistically significant BP differences between inflation and deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.
Pressure Regulators as Valves for Saving Compressed Air and their Influence on System Dynamics
NASA Astrophysics Data System (ADS)
Dvořák, Lukáš; Fojtášek, Kamil
2015-05-01
Pressure regulators in the field of pneumatic mechanisms can be used as valves for saving compressed air. For example it can be used to reduce the pressure when the piston rod is retracting unloaded and thus it is possible to save some energy. However the problem is that saving valve can significantly affect the dynamics of the pneumatic system. The lower pressure in the piston rod chamber causes extension of time for retraction of the piston rod. This article compare the air consumption experimentally determined and calculated, measured curves of pressure in cylinder chambers and piston speed when saving valve is set up differently.
Yang, Luojia; Li, Zhijun; Yang, Yanmin; Zhu, Raymound; Summers, Randy; Deslauriers, Roxanne; Ye, Jian
2006-11-01
This study was carried out to determine if increased perfusion pressure during retrograde cerebral perfusion (RCP) provides better preservation of the brain Na+, K+-ATPase activity. Twenty pigs were subjected to anesthesia alone (control group, n=5), hypothermic circulatory arrest (HCA) (HCA group, n = 5), HCA+RCP at perfusion pressures of 24-29 mmHg (Low-pressure group, n=5), or HCA+RCP at perfusion pressures of 34-40 mmHg (High-pressure group, n = 5). The brain was harvested for the measurement of tissue Na+, K+-ATPase activity. Relative to the control pigs (67.2 +/- 2.1%), significant impairment of Na+, K+-ATPase activity was observed in all three experimental groups (29.8 +/- 7.4% in HCA group, 33.5 +/- 2.9% in the Low-pressure group, and 52.0 +/- 1.8% in the High-pressure group, p < 0.01). The best preservation of the enzyme, particularly in the cortex and cerebellum regions, was observed in the High-pressure group (p < 0.01). In conclusion, HCA causes severe impairment of Na+, K+-ATPase activity, and increasing perfusion pressures from 24-29 to 34-40 mmHg during RCP significantly improves preservation of Na+, K+-ATPase activity, and the improvement of the protection varies in different regions of the brain.
NASA Astrophysics Data System (ADS)
Alay, E.; Skotak, M.; Misistia, A.; Chandra, N.
2018-01-01
Dynamic loads on specimens in live-fire conditions as well as at different locations within and outside compressed-gas-driven shock tubes are determined by both static and total blast overpressure-time pressure pulses. The biomechanical loading on the specimen is determined by surface pressures that combine the effects of static, dynamic, and reflected pressures and specimen geometry. Surface pressure is both space and time dependent; it varies as a function of size, shape, and external contour of the specimens. In this work, we used two sets of specimens: (1) anthropometric dummy head and (2) a surrogate rodent headform instrumented with pressure sensors and subjected them to blast waves in the interior and at the exit of the shock tube. We demonstrate in this work that while inside the shock tube the biomechanical loading as determined by various pressure measures closely aligns with live-fire data and shock wave theory, significant deviations are found when tests are performed outside.
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Braun, M. J.; Mullen, R. L.
1986-01-01
In systems where the design inlet and outlet pressures P sub amb are maintained above the thermodynamic critical pressure P sub c, it is often assumed that heat and mass transfer are governed by single-phase relations and that two-phase flows cannot occur. This simple rule of thumb is adequate in many low-power designs but is inadequate for high-performance turbomachines, boilers, and other systems where two-phase regions can exist even though P sub amb P sub c. Heat and mass transfer and rotordynamic-fluid-mechanic restoring forces depend on momentum differences, and those for a two-phase zone can differ significantly from those for a single-phase zone. By using a laminar, variable-property bearing code and a rotating boiler code, pressure and temperature surfaces were determined that illustrate nesting of a two-phase region within a supercritical pressure region. The method of corresponding states is applied to bearings with reasonable rapport.
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Braun, M. J.; Mullen, R. L.
1986-01-01
In systems where the design inlet and outlet pressure P sub amb are maintained above the thermodynamic critical pressure P sub c, it is often assumed that heat and mass transfer are governed by single-phase relations and that two-phase flows cannot occur. This simple rule of thumb is adequate in many low-power designs but is inadequate for high-performance turbomachines, boilers, and other systems where two-phase regions can exist even though P sub amb P sub c. Heat and mass transfer and rotordynamic-fluid-mechanic restoring forces depend on momentum differences, and those for a two-phase zone can differ significantly from those for a single-phase zone. By using a laminar, variable-property bearing code and a rotating boiler code, pressure and temperature surfaces were determined that illustrate nesting of a two-phase region within a supercritical pressure region. The method of corresponding states is applied to bearings with reasonable rapport.
Thermogravimetric study of vapor pressure of TATP synthesized without recrystallization.
Mbah, Jonathan; Knott, Debra; Steward, Scott
2014-11-01
This study aims at characterizing the vapor pressure signatures generated by triacetone triperoxide (TATP) that was synthesized without recrystallization by thermogravimmetric analysis (TGA) for exploitation by standoff detection technologies of explosive devices. The thermal behavior of the nonrecrystallized sample was compared with reported values. Any phase change, melting point and decomposition identification were studied by differential scanning calorimeter. Vapor pressures were estimated by the Langmuir method of evaporation from an open surface in a vacuum. Vapor pressures of TATP at different temperatures were calculated using the linear logarithmic relationship obtained from benzoic acid reference standard. Sublimation of TATP was found to follow apparent zero-order kinetics and sublimes at steady rates at 298 K and above. While the enthalpy of sublimation found, 71.7 kJ mol(-1), is in agreement with reported values the vapor pressures deviated significantly. The differences in the vapor pressures behavior are attributable to the synthesis pathway chosen in this study. Copyright © 2014 Elsevier B.V. All rights reserved.
Does footprint depth correlate with foot motion and pressure?
Bates, K. T.; Savage, R.; Pataky, T. C.; Morse, S. A.; Webster, E.; Falkingham, P. L.; Ren, L.; Qian, Z.; Collins, D.; Bennett, M. R.; McClymont, J.; Crompton, R. H.
2013-01-01
Footprints are the most direct source of evidence about locomotor biomechanics in extinct vertebrates. One of the principal suppositions underpinning biomechanical inferences is that footprint geometry correlates with dynamic foot pressure, which, in turn, is linked with overall limb motion of the trackmaker. In this study, we perform the first quantitative test of this long-standing assumption, using topological statistical analysis of plantar pressures and experimental and computer-simulated footprints. In computer-simulated footprints, the relative distribution of depth differed from the distribution of both peak and pressure impulse in all simulations. Analysis of footprint samples with common loading inputs and similar depths reveals that only shallow footprints lack significant topological differences between depth and pressure distributions. Topological comparison of plantar pressures and experimental beach footprints demonstrates that geometry is highly dependent on overall print depth; deeper footprints are characterized by greater relative forefoot, and particularly toe, depth than shallow footprints. The highlighted difference between ‘shallow’ and ‘deep’ footprints clearly emphasizes the need to understand variation in foot mechanics across different degrees of substrate compliance. Overall, our results indicate that extreme caution is required when applying the ‘depth equals pressure’ paradigm to hominin footprints, and by extension, those of other extant and extinct tetrapods. PMID:23516064
Turbulence downstream of subcoronary stentless and stented aortic valves.
Funder, Jonas Amstrup; Frost, Markus Winther; Wierup, Per; Klaaborg, Kaj-Erik; Hjortdal, Vibeke; Nygaard, Hans; Hasenkam, J Michael
2011-08-11
Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses. Copyright © 2011 Elsevier Ltd. All rights reserved.
Is autonomic modulation different between European and Chinese astronauts?
Liu, Jiexin; Li, Yongzhi; Verheyden, Bart; Chen, Shanguang; Chen, Zhanghuang; Gai, Yuqing; Liu, Jianzhong; Gao, Jianyi; Xie, Qiong; Yuan, Ming; Li, Qin; Li, Li; Aubert, André E
2015-01-01
The objective was to investigate autonomic control in groups of European and Chinese astronauts and to identify similarities and differences. Beat-to-beat heart rate and finger blood pressure, brachial blood pressure, and respiratory frequency were measured from 10 astronauts (five European taking part in three different space missions and five Chinese astronauts taking part in two different space missions). Data recording was performed in the supine and standing positions at least 10 days before launch, and 1, 3, and 10 days after return. Cross-correlation analysis of heart rate and systolic pressure was used to assess cardiac baroreflex modulation. A fixed breathing protocol was performed to measure respiratory sinus arrhythmia and low-frequency power of systolic blood pressure variability. Although baseline cardiovascular parameters before spaceflight were similar in all astronauts in the supine position, a significant increase in sympathetic activity and a decrease in vagal modulation occurred in the European astronauts when standing; spaceflight resulted in a remarkable vagal decrease in European astronauts only. Similar baseline supine and standing values for heart rate, mean arterial pressure, and respiratory frequency were shown in both groups. Standing autonomic control was based on a balance of higher vagal and sympathetic modulation in European astronauts. Post-spaceflight orthostatic tachycardia was observed in all European astronauts, whereas post-spaceflight orthostatic tachycardia was significantly reduced in Chinese astronauts. The basis for orthostatic intolerance is not apparent; however, many possibilities can be considered and need to be further investigated, such as genetic diversities between races, astronaut selection, training, and nutrition, etc.
Is Autonomic Modulation Different between European and Chinese Astronauts?
Liu, Jiexin; Li, Yongzhi; Verheyden, Bart; Chen, Shanguang; Chen, Zhanghuang; Gai, Yuqing; Liu, Jianzhong; Gao, Jianyi; Xie, Qiong; Yuan, Ming; Li, Qin; Li, Li; Aubert, André E.
2015-01-01
Purpose The objective was to investigate autonomic control in groups of European and Chinese astronauts and to identify similarities and differences. Methods Beat-to-beat heart rate and finger blood pressure, brachial blood pressure, and respiratory frequency were measured from 10 astronauts (five European taking part in three different space missions and five Chinese astronauts taking part in two different space missions). Data recording was performed in the supine and standing positions at least 10 days before launch, and 1, 3, and 10 days after return. Cross-correlation analysis of heart rate and systolic pressure was used to assess cardiac baroreflex modulation. A fixed breathing protocol was performed to measure respiratory sinus arrhythmia and low-frequency power of systolic blood pressure variability. Results Although baseline cardiovascular parameters before spaceflight were similar in all astronauts in the supine position, a significant increase in sympathetic activity and a decrease in vagal modulation occurred in the European astronauts when standing; spaceflight resulted in a remarkable vagal decrease in European astronauts only. Similar baseline supine and standing values for heart rate, mean arterial pressure, and respiratory frequency were shown in both groups. Standing autonomic control was based on a balance of higher vagal and sympathetic modulation in European astronauts. Conclusion Post-spaceflight orthostatic tachycardia was observed in all European astronauts, whereas post-spaceflight orthostatic tachycardia was significantly reduced in Chinese astronauts. The basis for orthostatic intolerance is not apparent; however, many possibilities can be considered and need to be further investigated, such as genetic diversities between races, astronaut selection, training, and nutrition, etc. PMID:25799561
Thermal sensitivity and cardiovascular reactivity to stress in healthy males.
Conde-Guzón, Pablo Antonio; Bartolomé-Albistegui, María Teresa; Quirós, Pilar; Cabestrero, Raúl
2011-11-01
This paper examines the association of cardiovascular reactivity with thermal thresholds (detection and unpleasantness). Heart period (HP), systolic (SBP) and diastolic (DBP) blood pressure of 42 health young males were recorded during a cardiovascular reactivity task (a videogame based upon Sidman's avoidance paradigm). Thermal sensitivity, assessing detection and unpleasantness thresholds with radiant heat in the forearm was also estimated for participants. Participants with differential scores in the cardiovascular variables from base line to task > or = P65 were considered as reactors and those how have differential scores < or = P35 were considered as non-reactors. Significant differences were observed between groups in the unpleasantness thresholds in blood pressure (BP) but not in HP. Reactors exhibited significant higher unpleasantness thresholds than non-reactors. No significant differences were obtained in detection thresholds between groups.
Ye, Ping-xian; Ye, Ping-zhen; Zhu, Jian-hua; Chen, Wei; Gao, Dan-chen
2014-05-01
To investigate the effect of atorvastatin on exercise tolerance in patients with diastolic dysfunction and exercise-induced hypertension. A randomized, double-blind, placebo-controlled prospective study was performed. Sixty patients with diastolic dysfunction (mitral flow velocity E/A <1) and exercise-induced hypertension (SBP>200 mm Hg) treated with atorvastatin (20 mg q.d) or placebo for 1 year. Cardiopulmonary exercise test and exercise blood pressure measurement were performed. Plasma B-natriuretic peptide (BNP) concentration at rest and at peak exercise, plasma high sensitive-C reaction protein (hs-CRP) and endothelin (ET) concentration were determined at baseline and after treatment. After treatment by atorvastatin, the resting SBP, pulse pressure, the peak exercise SBP and BNP were significantly decreased; and the exercise time, metabolic equivalent, maximal oxygen uptake and anaerobic threshold were increased. All of these parameters had significant differences with baseline levels (P<0.05) and the rest pulse pressure, the peak exercise SBP and BNP, and the exercise time had significant differences compared with placebo treatment (P<0.05). Plasma concentrations of hs-CRP and ET were markedly reduced by atorvastatin treatment compared with baseline and placebo (P<0.05). No difference in above parameters was found before and after placebo treatment (P>0.05). In patients with diastolic dysfunction at rest and exercise-induced hypertension, atorvastatin can effectively reduce plasma hs-CRP and ET level, lower blood pressure and peak exercise SBP, decrease peak exercise plasma BNP concentration, and ultimately improve exercise tolerance.
Braun, Christina; Trim, Cynthia M; Eggleston, Randy B
2009-01-01
To investigate the impact of a change in body position on blood gases and arterial blood pressures in foals anesthetized with guaifenesin, ketamine, and xylazine. Prospective, randomized experimental study. Twelve Quarter Horse foals, age of 5.4 +/-0.9 months and weighing 222 +/- 48 kg. Foals were anesthetized with guaifenesin, ketamine, and xylazine for 40 minutes in lateral recumbency and then assigned to a change in lateral recumbency after hoisting (Group 1, n = 6), or no change (Group 2, n = 6). Oxygen 15 L minute(-1) was insufflated into the endotracheal tube throughout anesthesia. Arterial blood pressure, heart rate, respiratory rate (f(R)), inspired fraction of oxygen (FIO(2)), and end-tidal carbon dioxide (PE'CO(2)) were measured every 5 minutes. Arterial pH and blood gases [arterial partial pressure of oxygen (PaO(2)), arterial partial pressure of carbon dioxide (PaCO(2))] were measured at 10, 30, and 40 minutes after induction, and 5 minutes after hoisting. Alveolar dead space ventilation and PaO(2)/FIO(2) were calculated. Two repeated measures models were used. All hypothesis tests were two-sided and significance level was alpha = 0.05. All values are presented as least square means +/- SE. Values at time-matched points from the two groups were not significantly different so they were combined. Arterial partial pressure of oxygen decreased significantly from 149 +/- 14.4 mmHg before hoisting to 92 +/- 11.6 mmHg after hoisting (p = 0.0013). The PaO(2)/FIO(2) ratio decreased from 275 +/- 30 to 175 +/- 24 (p = 0.0055). End-tidal carbon dioxide decreased significantly from 48.7 +/- 1.6 to 44.5 +/- 1.2 mmHg (p = 0.021). Arterial partial pressure of carbon dioxide, blood pressures and heart rates measured 5 minutes after hoisting were not different from measurements obtained before hoisting. Hoisting decreased PaO(2) in anesthetized healthy foals. Administration of supplemental oxygen is recommended to counter the decrease in oxygenation and PaO(2) measurement is necessary to detect early changes.
Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio
2016-01-01
The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF6, 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity. PMID:27957500
Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Velez-Montoya, Raul; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio
2016-01-01
The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF 6 , 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF 6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF 6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity.
Elsyad, Moustafa Abdou; El-Waseef, Fatma Ahmad; Al-Mahdy, Yasmeen Fathy; Fouad, Mohammed Mohammed
2013-08-01
This study aimed to evaluate mandibular denture base deformation along with three impression techniques used for implant-retained overdenture. Ten edentulous patients (five men and five women) received two implants in the canine region of the mandible and three duplicate mandibular overdentures which were constructed with mucostatic, selective pressure, and definitive pressure impression techniques. Ball abutments and respective gold matrices were used to connect the overdentures to the implants. Six linear strain gauges were bonded to the lingual polished surface of each duplicate overdenture at midline and implant areas to measure strain during maximal clenching and gum chewing. The strains recorded at midline were compressive while strains at implant areas were tensile. Clenching recorded significant higher strain when compared with gum chewing for all techniques. The mucostatic technique recorded the highest strain and the definite pressure technique recorded the lowest. There was no significant difference between the strain recorded with mucostatic technique and that registered with selective pressure technique. The highest strain was recorded at the level of ball abutment's top with the mucostatic technique during clenching. Definite pressure impression technique for implant-retained mandibular overdenture is associated with minimal denture deformation during function when compared with mucostatic and selective pressure techniques. Reinforcement of the denture base over the implants may be recommended to increase resistance of fracture when mucostatic or selective pressure impression technique is used. © 2012 John Wiley & Sons A/S.
Socioeconomic Status Modifies the Seasonal Effect on Blood Pressure
Cois, Annibale; Ehrlich, Rodney
2015-01-01
Abstract Seasonal variations in blood pressure have been consistently reported. However, uncertainty remains about the size of the seasonal effect in different regions, and about factors that explain the differences observed across and within populations. Using data from a national panel study, we investigated seasonal variations in blood pressure in the South African adult population, and whether these variations differed across socioeconomic strata. We estimated age-specific seasonal effects on blood pressure using a multilevel structural equation model, with repeated measurements nested within subjects. Effect modification by socioeconomic status was assessed by repeating the analyses in the subpopulations defined by levels of education, household income per capita, and type of housing. In men and women, season had a statistically significant effect on blood pressure, with higher levels in winter and lower levels in summer. For systolic blood pressure, the magnitude of the seasonal effect was 4.25/4.21 mmHg (women/men) and was higher in the older age groups. For diastolic blood pressure, the effect size was 4.00/4.01 mmHg, with no evident age trend. Seasonal effects were higher among subjects in the lowest socioeconomic classes than in the highest, with differences between 2.4 and 7.7 mmHg, depending on gender, whether systolic or diastolic blood pressure, and socioeconomic status indicator. In the South African adult population, blood pressure shows seasonal variation modified by age and socioeconomic status. These variations have epidemiological, clinical, and public health implications, including the prospect of population level intervention to reduce elevated risk of cold weather cardiovascular morbidity. PMID:26334893
Shao, Liang; Heizhati, Mulalibieke; Yao, Xiaoguang; Wang, Yingchun; Abulikemu, Suofeiya; Zhang, Delian; Zhou, Ling; Hong, Jing; Li, Nanfang
2018-05-01
In this cross-sectional study, we analyzed the potential association between sleep measures and blood pressure variability. Ninety-three middle-aged hypertensive males, who underwent polysomnography and 24-h ambulatory blood pressure monitoring, were enrolled. Blood pressure variability was assessed by blood pressure standard deviation. Obstructive sleep apnea (apnea hypopnea index ≥ 15) was diagnosed in 52 (55.91%) patients. Mean body mass index and age were 27.77 ± 3.11 kg/m 2 and 44.05 ± 8.07 years, respectively. Hypertensive males with obstructive sleep apnea showed significantly higher 24-h, diurnal, and nocturnal diastolic blood pressure variability, compared to those without obstructive sleep apnea. While total cohort was further divided into two groups using the median of oxygen desaturation index, another indicator for severity of OSA, significant differences were also observed in 24-h, diurnal, and nocturnal diastolic blood pressure variability between two groups with higher and lower oxygen desaturation index. While subjects were also divided into two groups via the mean of sleep stage 1, hypertensive males with sleep stage 1 ≥ 8.1% showed significantly higher diurnal diastolic blood pressure variability than those with sleep stage 1 < 8.1%. Apnea hypopnea index was independently associated with 24-h and nocturnal diastolic blood pressure variability; oxygen desaturation index of 3% with 24-h diastolic, diurnal, and nocturnal diastolic blood pressure; and sleep stage 1 was with 24-h and with diurnal diastolic blood pressure variability in all study subjects. Effects of obstructive sleep apnea on blood pressure variability may not be limited nocturnally.
Rondon, Atila; Leslie, Bruno; Arcuri, Leonardo Javier; Ortiz, Valdemar; Macedo, Antonio
2015-09-01
To assess whether crossing rectus abdominis muscle strips, as proposed by Yachia, would change urinary catheterizable conduit's pressure profilometry, in static and dynamic conditions. Non-randomized selection of 20 continent patients that underwent Macedo's ileum-based reservoir, 10 including Yachia's technique (Study Group) and 10 without this mechanism of continence (Control Group). Demographics and cystometric data were assessed. Conduit's pressure profilometry was obtained by infusing saline through a multichannel catheter, at rest and during Valsalva maneuver. We assessed the pressure: (a) in the bladder; (b) in conduit's proximal segment; and (c) in conduit's distal segment, which is presumably the abdominal wall and crossed muscle strips site. Mean age at surgery was 6.1 years in the Control Group and 7.7 years in the Study Group. There was no statistically significant difference between groups regarding maximum cystometric bladder capacity and leakage point pressure. At rest, the pressure profilometry showed similar results between groups in all segments analyzed. During Valsalva maneuver, pressure profilometry showed similar results between groups in bladder and conduit's proximal segment pressure. In this condition, conduit's distal segment pressure in the Study Group (Mean = 72.9 and Peak = 128.7 cmH2 O) was significantly greater (P < 0.05) than conduit's distal segment pressure in the Control Group (Mean = 48.3 and Peak = 65.1 cmH2 O). Crossing muscle strips over the conduit significantly increases the pressure in its distal segment during contraction of the rectus abdominis muscle, which can be important in moments of sudden increase in abdominal pressure in order to keep continence. © 2014 Wiley Periodicals, Inc.
Effects of Age on Esophageal Motility: Use of High-resolution Esophageal Impedance Manometry
Shim, Young Kwang; Kim, Nayoung; Park, Yo Han; Lee, Jong-Chan; Sung, Jihee; Choi, Yoon Jin; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2017-01-01
Background/Aims Disturbances of esophageal motility have been reported to be more frequent the aged population. However, the physiology of disturbances in esophageal motility during aging is unclear. The aim of this study was to evaluate the effects of age on esophageal motility using high-resolution esophageal impedance manometry (HRIM). Methods Esophageal motor function of 268 subjects were measured using HRIM in 3 age groups, < 40 years (Group A, n = 32), 40–65 years (Group B, n = 185), and > 65 years (Group C, n = 62). Lower esophageal sphincter (LES) and upper esophageal sphincter (UES) pressures, integrated relaxation pressure, distal contractile integral, contractile front velocity, distal latency, and pressures and duration of contraction on 4 positions along the esophagus, and complete bolus transit were measured. Results Basal UES pressure was lower in Group C (P < 0.001) but there was no significant difference in the LES pressure among groups. Contractile duration on position 3 (10 cm from proximal LES high pressure zone) was longer in Group C (P = 0.001), and the contractile amplitude on position 4 (5 cm from proximal LES high pressure zone) was lower in Group C (P = 0.005). Distal contractile integral was lower in Group C (P = 0.037). Contractile front velocity (P = 0.015) and the onset velocity (P = 0.040) was lower in Group C. There was no significant difference in impedance values. Conclusions The decrease of UES pressure, distal esophageal motility, and peristaltic velocity might be related with esophageal symptoms in the aged population. PMID:28163259
Effects of contrast media on the hepato-pancreato-biliary system
Topcu, Omer; Kurt, Atilla; Nadir, Isilay; Arici, Sema; Koyuncu, Ayhan; Aydin, Cengiz
2009-01-01
AIM: To determine the effects of high osmolarity contrast media (HOCM) and iso-osmolar contrast media (CM) application, with or without pressure, on hepato-pancreato-biliary (HPB) system. METHODS: Sixty rats were divided into six equal groups as follows: Group 1: (0.9% NaCl, control), Group 2: (diatrizoate meglumine Na, ionic HOCM, Urographin®), Group 3: (iodixanol, iso-osmolar non-ionic CM, Visipaque®); each of which was applied without pressure, whereas the animals of the remaining three groups (1p, 2p, 3p) were subjected to the same CM with pressure. We performed a duodenal puncture and introduced a catheter into the ampulla. After the catheterization, 0.2 mL CM or 0.9% NaCl was injected with or without pressure. Blood samples were taken for biochemical evaluations. The histopathological examinations of liver, common bile duct, and pancreas were performed. RESULTS: There were no significant differences between the six groups for blood amylase, alanine aminotransferases, aspartate aminotransferases, bilirubin levels (P > 0.05). Alkaline phosphatase and γ glutamyl transaminase levels were higher (P < 0.05) in the Urographin® groups (2, 2p) than the Visipaque® groups (3, 3p), or control groups (1, 1p). Hepatocyte necrosis, portal area inflammation, and Kupffer’s cell hyperplasia were higher (P < 0.05) in the study groups than the control group. However, there were no significant differences (P > 0.05) between HOCM (2, 2p) and iso-osmolar CM (3, 3p) groups. Bile duct proliferation and regeneration in the Urographin® groups (2, 2p) were significantly higher (P < 0.05) than the Visipaque® groups (3, 3p) or the control groups (1, 1p). Although CM caused minor damage to the pancreas, there were no statistically significant differences (P > 0.05) between the groups. Application of the CM with pressure did not cause additional damage to the HPB system. CONCLUSION: Iso-osmolar, non-ionic CM could be more reliable than the ionic HOCM, whereas the application of pressure during the CM application had no effect on the HPB system. PMID:19824112