Sample records for pressure sampling frequency

  1. The differential path phase comparison method for determining pressure derivatives of elastic constants of solids

    NASA Astrophysics Data System (ADS)

    Peselnick, L.

    1982-08-01

    An ultrasonic method is presented which combines features of the differential path and the phase comparison methods. The proposed differential path phase comparison method, referred to as the `hybrid' method for brevity, eliminates errors resulting from phase changes in the bond between the sample and buffer rod. Define r(P) [and R(P)] as the square of the normalized frequency for cancellation of sample waves for shear [and for compressional] waves. Define N as the number of wavelengths in twice the sample length. The pressure derivatives r'(P) and R' (P) for samples of Alcoa 2024-T4 aluminum were obtained by using the phase comparison and the hybrid methods. The values of the pressure derivatives obtained by using the phase comparison method show variations by as much as 40% for small values of N (N < 50). The pressure derivatives as determined from the hybrid method are reproducible to within ±2% independent of N. The values of the pressure derivatives determined by the phase comparison method for large N are the same as those determined by the hybrid method. Advantages of the hybrid method are (1) no pressure dependent phase shift at the buffer-sample interface, (2) elimination of deviatoric stress in the sample portion of the sample assembly with application of hydrostatic pressure, and (3) operation at lower ultrasonic frequencies (for comparable sample lengths), which eliminates detrimental high frequency ultrasonic problems. A reduction of the uncertainties of the pressure derivatives of single crystals and of low porosity polycrystals permits extrapolation of such experimental data to deeper mantle depths.

  2. Infrared Study of 1,3,5-triamino-2,4,6-trinitrobenzene Under High Pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pravica,M.; Yulga, B.; Liu, Z.

    We report synchrotron Fourier transform infrared measurements of 1,3,5-triamino-2,4,6-trinitrobenzene in the mid-IR and far-IR spectral regions up to {approx}10GPa , using KBr or petroleum jelly to compress the samples. During the far-IR experiment, we cycled the pressure, measuring IR spectra at various pressures, to determine whether the sample survived. In both experiments, no phase transition was observed. In the high frequency region ({approx}3000cm{sup -1}) , the peak frequencies of the NH{sub 2} symmetric and antisymmetric vibrational modes decrease with increasing pressure, indicating strengthening of intermolecular hydrogen bonding with pressure.

  3. Surface chemical structure of poly(ethylene naphthalate) films during degradation in low-pressure high-frequency plasma treatments

    NASA Astrophysics Data System (ADS)

    Kamata, Noritsugu; Yuji, Toshifumi; Thungsuk, Nuttee; Arunrungrusmi, Somchai; Chansri, Pakpoom; Kinoshita, Hiroyuki; Mungkung, Narong

    2018-06-01

    The surface chemical structure of poly(ethylene naphthalate) (PEN) films treated with a low-pressure, high-frequency plasma was investigated by storing in a box at room temperature to protect the PEN film surface from dust. The functional groups on the PEN film surface changed over time. The functional groups of –C=O, –COH, and –COOH were abundant in the Ar + O2 mixture gas plasma-treated PEN samples as compared with those in untreated PEN samples. The changes occurred rapidly after 2 d following the plasma treatment, reaching steady states 8 d after the treatment. Hydrophobicity had an inverse relationship with the concentration of these functional groups on the surface. Thus, the effect of the low-pressure high-frequency plasma treatment on PEN varies as a function of storage time. This means that radical oxygen and oxygen molecules are clearly generated in the plasma, and this is one index to confirm that radical reaction has definitely occurred between the gas and the PEN film surface with a low-pressure high-frequency plasma.

  4. Seismic wave attenuation and velocity dispersion in UAE carbonates

    NASA Astrophysics Data System (ADS)

    Ogunsami, Abdulwaheed Remi

    Interpreting the seismic property of fluids in hydrocarbon reservoirs at low frequency scale has been a cherished goal of petroleum geophysics research for decades. Lately, there has been tremendous interest in understanding attenuation as a result of fluid flow in porous media. Although interesting, the emerging experimental and theoretical information still remain ambiguous and are practically not utilized for reasons not too obscure. Attenuation is frequency dependent and hard to measure in the laboratory at low frequency. This thesis describes and reports the results of an experimental study of low frequency attenuation and velocity dispersion on a selected carbonate reservoir samples in the United Arab Emirates (UAE). For the low frequency measurements, stress-strain method was used to measure the moduli from which the velocity is derived. Attenuation was measured as the phase difference between the applied stress and the strain. For the ultrasonic component, the pulse propagation method was employed. To study the fluid effect especially at reservoir in situ conditions, the measurements were made dry and saturated with liquid butane and brine at differential pressures of up to 5000 psi with pore pressure held constant at 500 psi. Similarly to what has been documented in the literatures for sandstone, attenuation of the bulk compressibility mode dominates the losses in these dry and somewhat partially saturated carbonate samples with butane and brine. Overall, the observed attenuation cannot be simply said to be frequency dependent within this low seismic band. While attenuation seems to be practically constant in the low frequency band for sample 3H, such conclusion cannot be made for sample 7H. For the velocities, significant dispersion is observed and Gassmann generally fails to match the measured velocities. Only the squirt model fairly fits the velocities, but not at all pressures. Although the observed dispersion is larger than Biot's prediction, the fact that Squirt (Biot-Squirt and Gassmann-Squirt) over predicts the velocities at low pressure (e.g. Biot- Squirt from 500 psi for samples 7H, 8H and 10V) and under predicts at higher pressures (e.g. Gassman squirt beyond 1000 Psi to as high as 3500 psi for 10V and 7V) suggests that the Squirt model seems to contribute to the overall dispersion in these carbonate samples. In addition, although Gassmann fairly predicts some of the butane saturated velocity, it is not applicable for these carbonate samples when saturated with brine.

  5. Formulation of blade-flutter spectral analyses in stationary reference frame

    NASA Technical Reports Server (NTRS)

    Kurkov, A. P.

    1984-01-01

    Analytic representations are developed for the discrete blade deflection and the continuous tip static pressure fields in a stationary reference frame. Considered are the sampling rates equal to the rotational frequency, equal to blade passing frequency, and for the pressure, equal to a multiple of the blade passing frequency. For the last two rates the expressions for determining the nodal diameters from the spectra are included. A procedure is presented for transforming the complete unsteady pressure field into a rotating frame of reference. The determination of the true flutter frequency by using two sensors is described. To illustrate their use, the developed procedures are used to interpret selected experimental results.

  6. Split Hopkinson resonant bar test for sonic-frequency acoustic velocity and attenuation measurements of small, isotropic geological samples.

    PubMed

    Nakagawa, Seiji

    2011-04-01

    Mechanical properties (seismic velocities and attenuation) of geological materials are often frequency dependent, which necessitates measurements of the properties at frequencies relevant to a problem at hand. Conventional acoustic resonant bar tests allow measuring seismic properties of rocks and sediments at sonic frequencies (several kilohertz) that are close to the frequencies employed for geophysical exploration of oil and gas resources. However, the tests require a long, slender sample, which is often difficult to obtain from the deep subsurface or from weak and fractured geological formations. In this paper, an alternative measurement technique to conventional resonant bar tests is presented. This technique uses only a small, jacketed rock or sediment core sample mediating a pair of long, metal extension bars with attached seismic source and receiver-the same geometry as the split Hopkinson pressure bar test for large-strain, dynamic impact experiments. Because of the length and mass added to the sample, the resonance frequency of the entire system can be lowered significantly, compared to the sample alone. The experiment can be conducted under elevated confining pressures up to tens of MPa and temperatures above 100 [ordinal indicator, masculine]C, and concurrently with x-ray CT imaging. The described split Hopkinson resonant bar test is applied in two steps. First, extension and torsion-mode resonance frequencies and attenuation of the entire system are measured. Next, numerical inversions for the complex Young's and shear moduli of the sample are performed. One particularly important step is the correction of the inverted Young's moduli for the effect of sample-rod interfaces. Examples of the application are given for homogeneous, isotropic polymer samples, and a natural rock sample. © 2011 American Institute of Physics

  7. Influence of thermodynamic properties of a thermo-acoustic emitter on the efficiency of thermal airborne ultrasound generation.

    PubMed

    Daschewski, M; Kreutzbruck, M; Prager, J

    2015-12-01

    In this work we experimentally verify the theoretical prediction of the recently published Energy Density Fluctuation Model (EDF-model) of thermo-acoustic sound generation. Particularly, we investigate experimentally the influence of thermal inertia of an electrically conductive film on the efficiency of thermal airborne ultrasound generation predicted by the EDF-model. Unlike widely used theories, the EDF-model predicts that the thermal inertia of the electrically conductive film is a frequency-dependent parameter. Its influence grows non-linearly with the increase of excitation frequency and reduces the efficiency of the ultrasound generation. Thus, this parameter is the major limiting factor for the efficient thermal airborne ultrasound generation in the MHz-range. To verify this theoretical prediction experimentally, five thermo-acoustic emitter samples consisting of Indium-Tin-Oxide (ITO) coatings of different thicknesses (from 65 nm to 1.44 μm) on quartz glass substrates were tested for airborne ultrasound generation in a frequency range from 10 kHz to 800 kHz. For the measurement of thermally generated sound pressures a laser Doppler vibrometer combined with a 12 μm thin polyethylene foil was used as the sound pressure detector. All tested thermo-acoustic emitter samples showed a resonance-free frequency response in the entire tested frequency range. The thermal inertia of the heat producing film acts as a low-pass filter and reduces the generated sound pressure with the increasing excitation frequency and the ITO film thickness. The difference of generated sound pressure levels for samples with 65 nm and 1.44 μm thickness is in the order of about 6 dB at 50 kHz and of about 12 dB at 500 kHz. A comparison of sound pressure levels measured experimentally and those predicted by the EDF-model shows for all tested emitter samples a relative error of less than ±6%. Thus, experimental results confirm the prediction of the EDF-model and show that the model can be applied for design and optimization of thermo-acoustic airborne ultrasound emitters. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. A new method for finding and characterizing galaxy groups via low-frequency radio surveys

    NASA Astrophysics Data System (ADS)

    Croston, J. H.; Ineson, J.; Hardcastle, M. J.; Mingo, B.

    2017-09-01

    We describe a new method for identifying and characterizing the thermodynamic state of large samples of evolved galaxy groups at high redshifts using high-resolution, low-frequency radio surveys, such as those that will be carried out with LOFAR and the Square Kilometre Array. We identify a sub-population of morphologically regular powerful [Fanaroff-Riley type II (FR II)] radio galaxies and demonstrate that, for this sub-population, the internal pressure of the radio lobes is a reliable tracer of the external intragroup/intracluster medium (ICM) pressure, and that the assumption of a universal pressure profile for relaxed groups enables the total mass and X-ray luminosity to be estimated. Using a sample of well-studied FR II radio galaxies, we demonstrate that our method enables the estimation of group/cluster X-ray luminosities over three orders of magnitude in luminosity to within a factor of ˜2 from low-frequency radio properties alone. Our method could provide a powerful new tool for building samples of thousands of evolved galaxy groups at z > 1 and characterizing their ICM.

  9. High pressure Raman spectroscopy of H2O-CH3OH mixtures.

    PubMed

    Hsieh, Wen-Pin; Chien, Yu-Hsiang

    2015-02-23

    Complex intra-molecular interactions and the hydrogen-bonding network in H2O-volatile mixtures play critical roles in many dynamics processes in physical chemistry, biology, and Earth and planetary sciences. We used high pressure Raman spectroscopy to study the pressure evolution of vibrational frequencies and bonding behavior in H2O-CH3OH mixtures. We found that the presence of low CH3OH content in H2O increases the transition pressure where water crystallizes to ice VI, but does not significantly change the pressure where ice VI transforms to ice VII. Furthermore, the stiffening rates of C-H stretching frequencies dω/dP in CH3OH significantly decrease upon the crystallization of water, and the softening rates of the O-H stretching frequencies of ice VII are suppressed over a narrow pressure range, after which the frequencies of these modes shift with pressure in ways similar to pure CH3OH and ice VII, respectively. Such complex pressure evolution of Raman frequencies along with pronounced variations in Raman intensities of CH3OH within the sample, and the hysteresis of the water-ice VI phase transition suggest pressure-induced segregation of low content CH3OH from ice VII. These findings indicate the significant influence of volatiles on the crystallization of sub-surface ocean and thermal evolution within large icy planets and satellites.

  10. Acoustic velocity in rift basin mudstones: effects of in situ stress and sample lithology, and its relation to formation strength

    NASA Astrophysics Data System (ADS)

    Zakharova, N. V.; Goldberg, D.

    2017-12-01

    Acoustic/sonic velocity (Vp) provides one of the best proxies for formation strength, which is essential for geomechanical modeling and formation evaluation. Vp-strength relations need to be built empirically for specific basins and/or rock types. Since velocity is stress- and frequency-dependent, such relations can be very sensitive to experimental conditions; therefore, it is important to quantify their effect on velocity values. In this study, we present confined velocity and strength measurements for over 70 samples from the Newark Rift basin, a candidate site for carbon sequestration, and one of the largest in a series of the Mesozoic rift basins on the eastern North-American coast. Acoustic velocity measurements were obtained for a range of confining pressures from 0 to 6,000 psi, roughly corresponding to in situ confining pressure range. Although, overall, Vp values tend to increase with increasing pressure, the degree of Vp response to stress varies dramatically from sample to sample, and does not appear to correlate directly to lithology or porosity. Select samples exhibit near-zero change in Vp with increasing confining pressure, while others are characterized by up to 15% Vp change with 3,000 psi increase in confining pressure. Compared to sonic logs, the low-stress Vp values usually underestimate sonic velocities, while high-stress values tend to overestimate them. Therefore, a systematic frequency-dependent core-log difference is not observed in these rift basin formations, but accounting for Vp dependence on confining pressure is important. We quantify the Vp-pressure dependence using laboratory acoustic measurements, and develop depth-dependent Vp-strength relation, which could be used with sonic logs for geomechanical analysis in similar Mesozoic rift basin formations.

  11. Study of Cavitation/Vaporization in Liquid Rocket Thruster Injectors

    DTIC Science & Technology

    2011-07-29

    Particles, Journal of Propulsion and Power, Vol. 16, No. 2, 2000, pp. 309-317. [6] Ciucci, A., Iaccarino, G., Amato, M., Numerical Investigation of 3D ...axis lying in A-A plane. A Druck pressure transducer with a response frequency of 2.5 kHz is used to measure the pressure. Sampling rate for pressure

  12. The interplay of frequency of volunteering and prosocial motivation on purpose in life in emerging adults.

    PubMed

    Okun, Morris A; Kim, Ga Young

    2016-01-01

    One developmental task in emerging adulthood is finding meaning and purpose in life. Volunteering has been touted as one role that fosters purpose in life. We examined whether the association between frequency of volunteering and purpose in life varies with pleasure-based prosocial motivation and pressure-based prosocial motivation in a sample of 576 undergraduates, ages 18-22 years old. In a regression analysis predicting purpose in life, the frequency of volunteering by pleasure-based prosocial motivation by pressure-based prosocial motivation interaction effect was significant (p = .042). Simple slopes analyses revealed that frequency of volunteering was not significantly (p = .478) related to purpose in life among college students who were low in both pleasure-based and pressure-based prosocial motivation. The findings of the present study highlight the importance of prosocial motivation for understanding whether emerging adults' purpose in life will be enhanced by volunteering.

  13. Frequency, pressure and strain dependence of nonlinear elasticity in Berea Sandstone

    DOE PAGES

    Riviere, Jacques; Johnson, Paul Allan; Marone, Chris; ...

    2016-04-14

    Acoustoelasticity measurements in a sample of room dry Berea sandstone are conducted at various loading frequencies to explore the transition between the quasi-static ( f → 0) and dynamic (few kilohertz) nonlinear elastic response. We carry out these measurements at multiple confining pressures and perform a multivariate regression analysis to quantify the dependence of the harmonic content on strain amplitude, frequency, and pressure. The modulus softening (equivalent to the harmonic at 0f) increases by a factor 2–3 over 3 orders of magnitude increase in frequency. Harmonics at 2f, 4f, and 6f exhibit similar behaviors. In contrast, the harmonic at 1fmore » appears frequency independent. This result corroborates previous studies showing that the nonlinear elasticity of rocks can be described with a minimum of two physical mechanisms. This study provides quantitative data that describes the rate dependency of nonlinear elasticity. Furthermore, these findings can be used to improve theories relating the macroscopic elastic response to microstructural features.« less

  14. A Novel Intracranial Pressure Readout Circuit for Passive Wireless LC Sensor.

    PubMed

    Wang, Fa; Zhang, Xuan; Shokoueinejad, Mehdi; Iskandar, Bermans J; Medow, Joshua E; Webster, John G

    2017-10-01

    We present a wide frequency range, low cost, wireless intracranial pressure monitoring system, which includes an implantable passive sensor and an external reader. The passive sensor consists of two spiral coils and transduces the pressure change to a resonant frequency shift. The external portable reader reads out the sensor's resonant frequency over a wide frequency range (35 MHz-2.7 GHz). We propose a novel circuit topology, which tracks the system's impedance and phase change at a high frequency with low-cost components. This circuit is very simple and reliable. A prototype has been developed, and measurement results demonstrate that the device achieves a suitable measurement distance (>2 cm), sufficient sample frequency (>6 Hz), fine resolution, and good measurement accuracy for medical practice. Responsivity of this prototype is 0.92 MHz/mmHg and resolution is 0.028 mmHg. COMSOL specific absorption rate simulation proves that this system is safe. Considerations to improve the device performance have been discussed, which include the size of antenna, the power radiation, the Analog-to-digital converter (ADC) choice, and the signal processing algorithm.

  15. Method and apparatus for determining pressure-induced frequency-shifts in shock-compressed materials

    DOEpatents

    Moore, David S.; Schmidt, Stephen C.

    1985-01-01

    A method and an apparatus for conducting coherent anti-Stokes Raman scattering spectroscopy in shock-compressed materials are disclosed. The apparatus includes a sample vessel having an optically transparent wall and an opposing optically reflective wall. Two coherent laser beams, a pump beam and a broadband Stokes beam, are directed through the window and focused on a portion of the sample. In the preferred embodiment, a projectile is fired from a high-pressure gas gun to impact the outside of the reflective wall, generating a planar shock wave which travels through the sample toward the window. The pump and Stokes beams result in the emission from the shock-compressed sample of a coherent anti-Stokes beam, which is emitted toward the approaching reflective wall of the vessel and reflected back through the window. The anti-Stokes beam is folded into a spectrometer for frequency analysis. The results of such analysis are useful for determining chemical and physical phenomena which occur during the shock-compression of the sample.

  16. Method and apparatus for determining pressure-induced frequency-shifts in shock-compressed materials

    DOEpatents

    Moore, D.S.; Schmidt, S.C.

    1983-12-16

    A method and an apparatus for conducting coherent anti-Stokes Raman scattering spectroscopy in shock-compressed materials are disclosed. The apparatus includes a sample vessel having an optically transparent wall and an opposing optically reflective wall. Two coherent laser beams, a pump beam and a broadband Stokes beam, are directed through the window and focused on a portion of the sample. In the preferred embodiment, a projectile is fired from a high-pressure gas gun to impact the outside of the reflective wall, generating a planar shock wave which travels through the sample toward the window. The pump and Stokes beams result in the emission from the shock-compressed sample of a coherent anti-Stokes beam, which is emitted toward the approaching reflective wall of the vessel and reflected back through the window. The anti-Stokes beam is folded into a spectrometer for frequency analysis. The results of such analysis are useful for determining chemical and physical phenomena which occur during the shock-compression of the sample.

  17. Dual THz comb spectroscopy

    NASA Astrophysics Data System (ADS)

    Yasui, Takeshi

    2017-08-01

    Optical frequency combs are innovative tools for broadband spectroscopy because a series of comb modes can serve as frequency markers that are traceable to a microwave frequency standard. However, a mode distribution that is too discrete limits the spectral sampling interval to the mode frequency spacing even though individual mode linewidth is sufficiently narrow. Here, using a combination of a spectral interleaving and dual-comb spectroscopy in the terahertz (THz) region, we achieved a spectral sampling interval equal to the mode linewidth rather than the mode spacing. The spectrally interleaved THz comb was realized by sweeping the laser repetition frequency and interleaving additional frequency marks. In low-pressure gas spectroscopy, we achieved an improved spectral sampling density of 2.5 MHz and enhanced spectral accuracy of 8.39 × 10-7 in the THz region. The proposed method is a powerful tool for simultaneously achieving high resolution, high accuracy, and broad spectral coverage in THz spectroscopy.

  18. Reservoir transport and poroelastic properties from oscillating pore pressure experiments

    NASA Astrophysics Data System (ADS)

    Hasanov, Azar K.

    Hydraulic transport properties of reservoir rocks, permeability and storage capacity are traditionally defined as rock properties, responsible for the passage of fluids through the porous rock sample, as well as their storage. The evaluation of both is an important part of any reservoir characterization workflow. Moreover, permeability and storage capacity are main inputs into any reservoir simulation study, routinely performed by reservoir engineers on almost any major oil and gas field in the world. An accurate reservoir simulation is essential for production forecast and economic analysis, hence the transport properties directly control the profitability of the petroleum reservoir and their estimation is vital for oil and gas industry. This thesis is devoted to an integrated study of reservoir rocks' hydraulic, streaming potential and poroelastic properties as measured with the oscillating pore pressure experiment. The oscillating pore pressure method is traditionally used to measure hydraulic transport properties. We modified the method and built an experimental setup, capable of measuring all aforementioned rock properties simultaneously. The measurements were carried out for four conventional reservoir-rock quality samples at a range of oscillation frequencies and effective stresses. An apparent frequency dependence of permeability and streaming potential coupling coefficient was observed. Measured frequency dispersion of drained poroelastic properties indicates an intrinsically inelastic nature of the porous mineral rock frame. Standard Linear Model demonstrated the best fit to the experimental dispersion data. Pore collapse and grain crushing effects took place during hydrostatic loading of the dolomitic sample and were observed in permeability, coupling coefficient and poroelastic measurements simultaneously. I established that hydraulically-measured storage capacities are overestimated by almost one order of magnitude when compared to elastically-derived ones. The fact that the values of storage capacities as estimated from the hydraulic component of the oscillating pore pressure experiment are unreliable was also demonstrated by comparing poroelastic Biot and Skempton coefficients. These coefficients were estimated both from hydraulic and strain measurements and the comparison of two datasets points out ambiguity of hydraulic measurements. I also introduce a novel method, which allowed us to estimate the permeability from the full range of acquired frequency data by utilizing a nonlinear least-squares regression. I additionally performed numerical simulation of oscillatory fluid flow. The simulated frequency-dependent results displayed an excellent agreement with both analytical solution and experimental data. This agreement proves that numerical simulation is a powerful tool in predicting frequency response of a porous rock sample to harmonic pore pressure excitations.

  19. Some phonatory and resonatory characteristics of the rock, pop, soul, and Swedish dance band styles of singing.

    PubMed

    Borch, D Zangger; Sundberg, Johan

    2011-09-01

    This investigation aims at describing voice function of four nonclassical styles of singing, Rock, Pop, Soul, and Swedish Dance Band. A male singer, professionally experienced in performing in these genres, sang representative tunes, both with their original lyrics and on the syllable /pae/. In addition, he sang tones in a triad pattern ranging from the pitch Bb2 to the pitch C4 on the syllable /pae/ in pressed and neutral phonation. An expert panel was successful in classifying the samples, thus suggesting that the samples were representative of the various styles. Subglottal pressure was estimated from oral pressure during the occlusion for the consonant [p]. Flow glottograms were obtained from inverse filtering. The four lowest formant frequencies differed between the styles. The mean of the subglottal pressure and the mean of the normalized amplitude quotient (NAQ), that is, the ratio between the flow pulse amplitude and the product of period and maximum flow declination rate, were plotted against the mean of fundamental frequency. In these graphs, Rock and Swedish Dance Band assumed opposite extreme positions with respect to subglottal pressure and mean phonation frequency, whereas the mean NAQ values differed less between the styles. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  20. Acoustic system for material transport

    NASA Technical Reports Server (NTRS)

    Barmatz, M. B.; Trinh, E. H.; Wang, T. G.; Elleman, D. D.; Jacobi, N. (Inventor)

    1983-01-01

    An object within a chamber is acoustically moved by applying wavelengths of different modes to the chamber to move the object between pressure wells formed by the modes. In one system, the object is placed in one end of the chamber while a resonant mode, applied along the length of the chamber, produces a pressure well at the location. The frequency is then switched to a second mode that produces a pressure well at the center of the chamber, to draw the object. When the object reaches the second pressure well and is still traveling towards the second end of the chamber, the acoustic frequency is again shifted to a third mode (which may equal the first model) that has a pressure well in the second end portion of the chamber, to draw the object. A heat source may be located near the second end of the chamber to heat the sample, and after the sample is heated it can be cooled by moving it in a corresponding manner back to the first end of the chamber. The transducers for levitating and moving the object may be all located at the cool first end of the chamber.

  1. A study of the eigenvectors of low frequency vibrational modes in crystalline cytidine via high pressure Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Lee, Scott A.

    2014-03-01

    High-pressure Raman spectroscopy has been used to study the eigenvectors and eigenvalues of the low-frequency vibrational modes of crystalline cytidine at 295 K by evaluating the logarithmic derivative of the vibrational frequency with respect to pressure: 1/ω dω/dP. Crystalline samples of molecular materials such as cytidine have vibrational modes that are localized within a molecular unit (``internal'' modes) as well as modes in which the molecular units vibrate against each other (``external'' modes). The value of the logarithmic derivative is a diagnostic probe of the nature of the eigenvector of the vibrational modes, making high pressure experiments a very useful probe for such studies. Internal stretching modes have low logarithmic derivatives while external as well as internal torsional and bending modes have higher logarithmic derivatives. All of the Raman modes below 200 cm-1 in cytidine are found to have high logarithmic derivatives, consistent with being either external modes or internal torsional or bending modes.

  2. High sensitivity pressure transducer based on the phase characteristics of GMI magnetic sensors

    NASA Astrophysics Data System (ADS)

    Benavides, L. S.; Costa Silva, E.; Costa Monteiro, E.; Hall Barbosa, C. R.

    2018-03-01

    This paper presents a new configuration for a GMI pressure transducer based on the reading of the phase characteristics of GMI sensor, intended for biomedical applications. The development process of this new class of magnetic field transducers is discussed, beginning with the definition of the ideal conditioning of the GMI sensor elements (dc level and frequency of the excitation current and sample length) and continuing with computational simulations of the full electronic circuit performed using the experimental data obtained from measured GMI curves, and have shown that the improvement in the sensitivity of GMI magnetometers is larger when phase-based transducers are used instead of magnitude-based transducers. Parameters of interest of the developed prototype are thoroughly analyzed, such as: sensitivity, linearity and frequency response. Also, the spectral noise density of the developed pressure transducer is evaluated and its resolution in the passband is estimated. A low-cost GMI pressure transducer was developed, presenting high resolution, high sensitivity and a frequency bandwidth compatible to the desired biomedical applications.

  3. Fluctuating pressures measured beneath a high-temperature, turbulent boundary layer on a flat plate at Mach number of 5

    NASA Technical Reports Server (NTRS)

    Parrott, Tony L.; Jones, Michael G.; Albertson, Cindy W.

    1989-01-01

    Fluctuating pressures were measured beneath a Mach 5, turbulent boundary layer on a flat plate with an array of piezoresistive sensors. The data were obtained with a digital signal acquisition system during a test run of 4 seconds. Data sampling rate was such that frequency analysis up to 62.5 kHz could be performed. To assess in situ frequency response of the sensors, a specially designed waveguide calibration system was employed to measure transfer functions of all sensors and related instrumentation. Pressure time histories were approximated well by a Gaussian prohibiting distribution. Pressure spectra were very repeatable over the array span of 76 mm. Total rms pressures ranged from 0.0017 to 0.0046 of the freestream dynamic pressure. Streamwise, space-time correlations exhibited expected decaying behavior of a turbulence generated pressure field. Average convection speed was 0.87 of freestream velocity. The trendless behavior with sensor separation indicated possible systematic errors.

  4. Experimental Evidence of Volcanic Earthquakes Induced by Different Fluid Types

    NASA Astrophysics Data System (ADS)

    Clarke, J. A.; Adam, L.; Sarout, J.; van Wijk, K.; Dautriat, J. D.; Kennedy, B.

    2017-12-01

    Low Frequency volcanic seismicity has long been associated with resonance in fluid-filled cracks or conduits driven by pressure perturbations at depth. In volcano monitoring, fluid movement, fracturing and the conduit geometry are interpreted based on field observations, laboratory experiments, and numerical models. Fluids in a volcanic environment include gasses, brine and magmas with different viscosities. Magma viscosity is a key influence on eruptive behaviour. For example, increasing magma viscosity is known to favour explosive eruptions. How different fluids affect volcano seismicity is not well understood. Here, we explore the effects of fluid type on volcano seismic signals. Frequency content in the signal, frequency of the events, source mechanism and quality factor are studied. We simulate volcano tectonic (fracturing) and volcano seismic (fluid movement) signatures in a controlled laboratory environment using a range of rock samples, fluid types and pressure conditions. The viscosity of the fluids spans six orders of magnitude, representing realistic volcanic fluids. Microseismicity is generated by venting pressurised fluids through pre-generated fracture networks in cylindrical rock core samples and detected by an array of 18 ultrasonic transducers. We fracture samples of two lithologies: 1) low porosity impermeable granite samples and 2) a permeable volcanic ash tuff sample. Permeability and porosity in the granites are due to a fracture network, while in the tuff a high porosity matrix ( 40 %) and a fracture network interact. The fluids used are nitrogen gas, water, and mixtures of water and glycerol. We generate and detect a myriad of seismic event types, some of which resemble well-known families of volcano-tectonic, low-frequency, hybrid and tremor-type seismicity. Samples with fluids of lower density and viscosity generate a higher number of seismic events. We will present an integrated analysis of the event types, frequency content, source locations and mechanisms. In addition, we explore the importance of seismic wave attenuation by studying the relationship between wave path and event frequency content.

  5. Airborne Lidar measurements of the atmospheric pressure profile with tunable Alexandrite lasers

    NASA Technical Reports Server (NTRS)

    Korb, C. L.; Schwemmer, G. K.; Dombrowski, M.; Milrod, J.; Walden, H.

    1986-01-01

    The first remote measurements of the atmospheric pressure profile made from an airborne platform are described. The measurements utilize a differential absorption lidar and tunable solid state Alexandrite lasers. The pressure measurement technique uses a high resolution oxygen A band where the absorption is highly pressure sensitive due to collision broadening. Absorption troughs and regions of minimum absorption were used between pairs of stongly absorption lines for these measurements. The trough technique allows the measurement to be greatly desensitized to the effects of laser frequency instabilities. The lidar system was set up to measure pressure with the on-line laser tuned to the absorption trough at 13147.3/cm and with the reference laser tuned to a nonabsorbing frequency near 13170.0/cm. The lidar signal returns were sampled with a 200 range gate (30 vertical resoltion) and averaged over 100 shots.

  6. Spectrally interleaved, comb-mode-resolved spectroscopy using swept dual terahertz combs

    PubMed Central

    Hsieh, Yi-Da; Iyonaga, Yuki; Sakaguchi, Yoshiyuki; Yokoyama, Shuko; Inaba, Hajime; Minoshima, Kaoru; Hindle, Francis; Araki, Tsutomu; Yasui, Takeshi

    2014-01-01

    Optical frequency combs are innovative tools for broadband spectroscopy because a series of comb modes can serve as frequency markers that are traceable to a microwave frequency standard. However, a mode distribution that is too discrete limits the spectral sampling interval to the mode frequency spacing even though individual mode linewidth is sufficiently narrow. Here, using a combination of a spectral interleaving and dual-comb spectroscopy in the terahertz (THz) region, we achieved a spectral sampling interval equal to the mode linewidth rather than the mode spacing. The spectrally interleaved THz comb was realized by sweeping the laser repetition frequency and interleaving additional frequency marks. In low-pressure gas spectroscopy, we achieved an improved spectral sampling density of 2.5 MHz and enhanced spectral accuracy of 8.39 × 10−7 in the THz region. The proposed method is a powerful tool for simultaneously achieving high resolution, high accuracy, and broad spectral coverage in THz spectroscopy. PMID:24448604

  7. Constant frequency pulsed phase-locked loop measuring device

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Kushnick, Peter W. (Inventor); Cantrell, John H. (Inventor)

    1993-01-01

    A measuring apparatus is presented that uses a fixed frequency oscillator to measure small changes in the phase velocity ultrasonic sound when a sample is exposed to environmental changes such as changes in pressure, temperature, etc. The invention automatically balances electrical phase shifts against the acoustical phase shifts in order to obtain an accurate measurement of electrical phase shifts.

  8. Dynamics of the outgoing turbulent boundary layer in a Mach 5 unswept compression ramp interaction

    NASA Technical Reports Server (NTRS)

    Gramann, Richard A.; Dolling, David S.

    1990-01-01

    Wall pressure fluctuations have been measured under the unsteady separation shock and on the ramp face in an unswept Mach 5 compression ramp interaction. The freestream Reynolds number was 51.0 x 10 to the 6th/m, and the incoming turbulent boundary layer developed on the tunnel floor under approximately adiabatic wall temperature conditions. Standard data-acquisition methods, as well as real-time and posttest conditional sampling techniques were used. The results show that the mean and rms pressure levels are strong functions of separation shock position. At all stations on the ramp, from the corner to where the pressure reaches the theoretical inviscid value, the pressure signals have two dominant components: a low frequency component characteristic of the global unsteadiness, which correlates with the separation shock motion, and a higher frequency component associated with turbulence. The former is the major contributor to the overall signal variance.

  9. Elastic Dispersion and Attenuation in Fully Saturated Sandstones: Role of Mineral Content, Porosity, and Pressures

    NASA Astrophysics Data System (ADS)

    Pimienta, Lucas; Borgomano, Jan V. M.; Fortin, Jérôme; Guéguen, Yves

    2017-12-01

    Because measuring the frequency dependence of elastic properties in the laboratory is a technical challenge, not enough experimental data exist to test the existing theories. We report measurements of three fluid-saturated sandstones over a broad frequency band: Wilkenson, Berea, and Bentheim sandstones. Those sandstones samples, chosen for their variable porosities and mineral content, are saturated by fluids of varying viscosities. The samples elastic response (Young's modulus and Poisson's ratio) and hydraulic response (fluid flow out of the sample) are measured as a function of frequency. Large dispersion and attenuation phenomena are observed over the investigated frequency range. For all samples, the variation at lowest frequency relates to a large fluid flow directly measured out of the rock samples. These are the cause (i.e., fluid flow) and consequence (i.e., dispersion/attenuation) of the transition between drained and undrained regimes. Consistently, the characteristic frequency correlates with permeability for each sandstone. Beyond this frequency, a second variation is observed for all samples, but the rocks behave differently. For Berea sandstone, an onset of dispersion/attenuation is expected from both Young's modulus and Poisson's ratio at highest frequency. For Bentheim and Wilkenson sandstones, however, only Young's modulus shows dispersion/attenuation phenomena. For Wilkenson sandstone, the viscoelastic-like dispersion/attenuation response is interpreted as squirt flow. For Bentheim sandstone, the second effect does not fully follow such response, which could be due to a lower accuracy in the measured attenuation or to the occurence of another physical effect in this rock sample.

  10. Effects of Ultrasound Frequency and Tissue Stiffness on the Histotripsy Intrinsic Threshold for Cavitation

    PubMed Central

    Vlaisavljevich, Eli; Lin, Kuang-Wei; Maxwell, Adam; Warnez, Matthew; Mancia, Lauren; Singh, Rahul; Putnam, Andrew J.; Fowlkes, Brian; Johnsen, Eric; Cain, Charles; Xu, Zhen

    2015-01-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated a cavitation cloud can be formed by a single pulse with one high amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1–2 cycles produced by 345 kHz, 500 kHz, 1.5 MHz, and 3 MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results demonstrated that the intrinsic threshold (the negative pressure at which probability=0.5) is independent of stiffness for Young’s moduli (E) < 1 MPa with only a small increase (~2–3 MPa) in the intrinsic threshold for tendon (E=380 MPa). Additionally, results for all samples showed only a small increase of ~2–3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7–30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly impacted by tissue stiffness or ultrasound frequency in hundreds of kHz to MHz range. PMID:25766571

  11. Effects of ultrasound frequency and tissue stiffness on the histotripsy intrinsic threshold for cavitation.

    PubMed

    Vlaisavljevich, Eli; Lin, Kuang-Wei; Maxwell, Adam; Warnez, Matthew T; Mancia, Lauren; Singh, Rahul; Putnam, Andrew J; Fowlkes, Brian; Johnsen, Eric; Cain, Charles; Xu, Zhen

    2015-06-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has indicated that a cavitation cloud can be formed by a single pulse with one high-amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue, and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1-2 cycles produced by 345-kHz, 500-kHz, 1.5-MHz and 3-MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured versus pressure amplitude. The results revealed that the intrinsic threshold (the negative pressure at which probability = 0.5) is independent of stiffness for Young's moduli (E) <1 MPa, with only a small increase (∼2-3 MPa) in the intrinsic threshold for tendon (E = 380 MPa). Additionally, results for all samples revealed only a small increase of ∼2-3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7 and 30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly affected by tissue stiffness or ultrasound frequency in the hundreds of kilohertz to megahertz range. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Improvement of technical purpose materials performance characteristics with the radio frequency low pressure plasma

    NASA Astrophysics Data System (ADS)

    Makhotkina, L. Yu; Khristoliubova, V. I.

    2017-11-01

    The main aim of the work is to solve the actual problem of increasing the competitiveness of tanning products by reducing the prime cost and improving the quality of finished products due to the increased durability of the working elements of tanneries. The impact of the low pressure radio frequency (RF) plasma in the processes of treating for modification of the materials for special purposes is considered in the article. The results of working elements of tanneries and the materials for special purposes sample processing by a RF low pressure plasma are described. As a result of leather materials nano structuring and nano modifying physical, mechanical and hygienic characteristics were increased. Processing of the technical purpose materials allows to increase operational performance of products and extend their lifespan.

  13. A novel multi-scale adaptive sampling-based approach for energy saving in leak detection for WSN-based water pipelines

    NASA Astrophysics Data System (ADS)

    Saqib, Najam us; Faizan Mysorewala, Muhammad; Cheded, Lahouari

    2017-12-01

    In this paper, we propose a novel monitoring strategy for a wireless sensor networks (WSNs)-based water pipeline network. Our strategy uses a multi-pronged approach to reduce energy consumption based on the use of two types of vibration sensors and pressure sensors, all having different energy levels, and a hierarchical adaptive sampling mechanism to determine the sampling frequency. The sampling rate of the sensors is adjusted according to the bandwidth of the vibration signal being monitored by using a wavelet-based adaptive thresholding scheme that calculates the new sampling frequency for the following cycle. In this multimodal sensing scheme, the duty-cycling approach is used for all sensors to reduce the sampling instances, such that the high-energy, high-precision (HE-HP) vibration sensors have low duty cycles, and the low-energy, low-precision (LE-LP) vibration sensors have high duty cycles. The low duty-cycling (HE-HP) vibration sensor adjusts the sampling frequency of the high duty-cycling (LE-LP) vibration sensor. The simulated test bed considered here consists of a water pipeline network which uses pressure and vibration sensors, with the latter having different energy consumptions and precision levels, at various locations in the network. This is all the more useful for energy conservation for extended monitoring. It is shown that by using the novel features of our proposed scheme, a significant reduction in energy consumption is achieved and the leak is effectively detected by the sensor node that is closest to it. Finally, both the total energy consumed by monitoring as well as the time to detect the leak by a WSN node are computed, and show the superiority of our proposed hierarchical adaptive sampling algorithm over a non-adaptive sampling approach.

  14. Atmospheric pressure reaction cell for operando sum frequency generation spectroscopy of ultrahigh vacuum grown model catalysts

    NASA Astrophysics Data System (ADS)

    Roiaz, Matteo; Pramhaas, Verena; Li, Xia; Rameshan, Christoph; Rupprechter, Günther

    2018-04-01

    A new custom-designed ultrahigh vacuum (UHV) chamber coupled to a UHV and atmospheric-pressure-compatible spectroscopic and catalytic reaction cell is described, which allows us to perform IR-vis sum frequency generation (SFG) vibrational spectroscopy during catalytic (kinetic) measurements. SFG spectroscopy is an exceptional tool to study vibrational properties of surface adsorbates under operando conditions, close to those of technical catalysis. This versatile setup allows performing surface science, SFG spectroscopy, catalysis, and electrochemical investigations on model systems, including single crystals, thin films, and deposited metal nanoparticles, under well-controlled conditions of gas composition, pressure, temperature, and potential. The UHV chamber enables us to prepare the model catalysts and to analyze their surface structure and composition by low energy electron diffraction and Auger electron spectroscopy, respectively. Thereafter, a sample transfer mechanism moves samples under UHV to the spectroscopic cell, avoiding air exposure. In the catalytic cell, SFG spectroscopy and catalytic tests (reactant/product analysis by mass spectrometry or gas chromatography) are performed simultaneously. A dedicated sample manipulation stage allows the model catalysts to be examined from LN2 temperature to 1273 K, with gaseous reactants in a pressure range from UHV to atmospheric. For post-reaction analysis, the SFG cell is rapidly evacuated and samples are transferred back to the UHV chamber. The capabilities of this new setup are demonstrated by benchmark results of CO adsorption on Pt and Pd(111) single crystal surfaces and of CO adsorption and oxidation on a ZrO2 supported Pt nanoparticle model catalyst grown by atomic layer deposition.

  15. Cardiovascular and stress responses to short-term noise exposures-A panel study in healthy males.

    PubMed

    Walker, Erica D; Brammer, Anthony; Cherniack, Martin G; Laden, Francine; Cavallari, Jennifer M

    2016-10-01

    While previous epidemiological studies report adverse effects of long-term noise exposure on cardiovascular health, the mechanisms responsible for these effects are unclear. We sought to elucidate the cardiovascular and stress response to short-term, low (31.5-125Hz) and high (500-2000Hz) frequency noise exposures. Healthy male (n=10) participants were monitored on multiple visits during no noise, low- or high-frequency noise exposure scenarios lasting 40min. Participants were fitted with an ambulatory electrocardiogram (ECG) and blood pressure measures and saliva samples were taken before, during and after noise exposures. ECGs were processed for measures of heart rate variability (HRV): high-frequency power (HF), low-frequency power (LF), the root of the mean squared difference between adjacent normal heart beats (N-N) intervals (RMSSD), and the standard deviation of N-N intervals (SDNN). Systolic blood pressure (SBP), diastolic blood pressure (DPB), and pulse were reported and saliva was analyzed for salivary cortisol and amylase. Multivariate mixed-effects linear regression models adjusted for age were used to identify statistically significant difference in outcomes by no noise, during noise or after noise exposure periods and whether this differed by noise frequency. A total of 658, 205, and 122, HRV, saliva, and blood pressure measurements were performed over 41 person days. Reductions in HRV (LF and RMSSD) were observed during noise exposure (a reduction of 19% (-35,-3.5) and 9.1% (-17,-1.1), respectively). After adjusting for noise frequency, during low frequency noise exposure, HF, LF, and SDNN were reduced (a reduction of 32% (-57,-6.2), 34% (-52,-15), and 16% (-26,-6.1), respectively) and during high frequency noise exposure, a 21% (-39,-2.3) reduction in LF, as compared to during no noise exposure, was found. No significant (p<0.05) changes in blood pressure, salivary cortisol, or amylase were observed. These results suggest that exposure to noise, and in particular, to low-frequency noise, negatively impacts HRV. The frequencies of noise should be considered when evaluating the cardiovascular health impacts of exposure. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Cardiovascular and Stress Responses to Short-Term Noise Exposures—A Panel Study in Healthy Males

    PubMed Central

    Walker, Erica D; Brammer, Anthony; Cherniack, Martin G; Laden, Francine; Cavallari, Jennifer M

    2016-01-01

    Background While previous epidemiological studies report adverse effects of long-term noise exposure on cardiovascular health, the mechanisms responsible for these effects are unclear. We sought to elucidate the cardiovascular and stress response to short-term, low (31.5-125 Hz) and high (500 – 2000 Hz) frequency noise exposures. Methods Healthy male (n = 10) participants were monitored on multiple visits during no noise, low- or high-frequency noise exposure scenarios lasting 40 minutes. Participants were fitted with an ambulatory electrocardiogram (ECG) and blood pressure measures and saliva samples were taken before, during and after noise exposures. ECGs were processed for measures of heart rate variability (HRV): high-frequency power (HF), low-frequency power (LF), the root of the mean squared difference between adjacent normal heart beats (N-N) intervals (RMSSD), and the standard deviation of N-N intervals (SDNN). Systolic blood pressure (SBP), diastolic blood pressure (DPB), and pulse were reported and saliva was analyzed for salivary cortisol and amylase. Multivariate mixed-effects linear regression models adjusted for age were used to identify statistically significant difference in outcomes by no noise, during noise or after noise exposure periods and whether this differed by noise frequency. Results A total of 658, 205, and 122, HRV, saliva,and blood pressure measurements were performed over 41 person days. Reductions in HRV (LF and RMSSD) were observed during noise exposure (a reduction of 19%(−35,−3.5) and 9.1%(−17,−1.1), respectively). After adjusting for noise frequency, during low frequency noise exposure, HF, LF, and SDNN were reduced (a reduction of 32%(−57,−6.2), 34%(−52,−15), and 16%(−26,−6.1), respectively and during high frequency noise exposure, a 21%(−39,−2.3) reduction in LF, as compared to during no noise exposure was found. No significant (p>0.05) changes in blood pressure,salivary cortisol or amylase were observed. Conclusions These results suggest that exposure to noise, and in particular, to low-frequency noise negatively impacts HRV. The frequencies of noise should be considered when evaluating the cardiovascular health impacts of exposure. PMID:27371930

  17. High pressure system for 3-D study of elastic anisotropy

    NASA Astrophysics Data System (ADS)

    Lokajicek, T.; Pros, Z.; Klima, K.

    2003-04-01

    New high pressure system was designed for the study of elastic anisotropy of condensed matter under high confining pressure up to 700 MPa. Simultaneously could be measured dynamic and static parameters: a) dynamic parameters by ultrasonic sounding, b) static parameters by measuring of spherical sample deformation. The measurement is carried out on spherical samples diameter 50 +/- 0.01 mm. Higher value of confining pressure was reached due to the new construction of sample positioning unit. The positioning unit is equipped with two Portecap step motors, which are located inside the vessel and make possible to rotate with the sphere and couple of piezoceramic transducers. Sample deformation is measured in the same direction as ultrasonic signal travel time. Only electric leads connects inner part of high pressure vessel with surrounding environment. Experimental set up enables: - simultaneous P-wave ultrasonic sounding, - measurement of current sample deformation at sounding points, - measurement of current value of confining pressure and - measurement of current stress media temperature. Air driven high pressure pump Haskel is used to produce high value of confining pressure up to 700 MPa. Ultrasonic signals are recorded by digital scope Agilent 54562 with sampling frequency 100 MHz. Control and measuring software was developed under Agilent VEE software environment working under MS Win 2000 operating system. Measuring set up was tested by measurement of monomineral spherical samples of quartz and corundum. Both of them have trigonal symmetry. The measurement showed that the P-wave velocity range of quartz was between 5.7-7.0 km/sec. and velocity range of corundum was between 9.7-10.9 km/sec. High pressure resistant LVDT transducers Mesing together with Intronix electronic unit were used to monitor sample deformation. Sample deformation is monitored with the accuracy of 0.1 micron. All test measurements proved the good accuracy of the whole measuring set up. This project was supported by Grant Agency of the Czech Republic No.: 205/01/1430.

  18. Elastic Nonlinear Response in Granular Media Under Resonance Conditions

    NASA Astrophysics Data System (ADS)

    Jia, X.; Johnson, P. A.

    2004-12-01

    We are studying the elastic linear and nonlinear behavior of granular media using dynamic wave methods. In the work presented here, our goal is to quantify the elastic nonlinear response by applying wave resonance. Resonance studies are desirable because they provide the means to easily study amplitude dependencies of elastic nonlinear behavior and thus to characterize the physical nature of the elastic nonlinearity. This work has implications for a variety of topics, in particular, the in situ nonlinear response of surface sediments. For this work we constructed an experimental cell in which high sensitivity dynamic resonance studies were conducted using granular media under controlled effective pressure. We limit our studies here to bulk modes but have the capability to employ shear waves as well. The granular media are composed of glass beads held under pressure by a piston, while applying resonance waves from transducers as both the excitation and the material probe. The container is closed with two fitted pistons and a normal load is applied to the granular sample across the top piston. Force and displacement are measured directly. Resonant frequency sweeps with frequencies corresponding to the fundamental bulk mode are applied to the longitudinal source transducer. The pore pressure in the system is 1 atm. The glass beads used in our experiments are of diameter 0.5 mm, randomly deposited in a duralumin cylinder of diameter 30 mm and height of 15 mm. This corresponds to a granular skeleton acoustic wave velocity of v ª 750m/s under 50 N of force [0.07 Mpa]. The loaded system gives fundamental mode resonances in the audio frequency band at half a wavelength where resonance frequency is effective-pressure dependent. The volume fraction of glass beads thus obtained is found to be 0.63 ± 0.01. Plane-wave generating and detecting transducers of diameter 30 mm are placed on axis at the top and bottom of the cylindrical container in direct contact with the glass beads. The wave signals are detected using a lock-in amplifier, and frequency and amplitude are recorded on computer. Drive frequency is swept from below to above the resonance mode. A typical frequency sweep is 3 kHz in width with a frequency sampling of 6 Hz. Frequency sweeps are applied at progressively increasing drive voltages to test for nonlinear-dynamical induced modulus softening. The resonance frequency at peak amplitude corresponds directly to modulus. We find significant elastic nonlinearity at all effective pressures, manifest by the fundamental-mode resonance curves decreasing progressively, at progressively increasing drive level. This is equivalent to progressive material softening with wave amplitude, meaning the wavespeed and modulus diminish. The wave dissipation simultaneously increases (Johnson and Sutin 2004). For example, at 0.11 Mpa effective pressure the observed change in resonance frequency of about 2.6% corresponds to a material bulk modulus decrease of about 5.2%. Strain amplitudes are 10-7-10-6. Thus, we would predict that surface sediments should have significant elastic nonlinear response beginning at about 10-6 strain amplitude. reference: Johnson, P. and A. Sutin, Slow dynamics in diverse solids, J. Acoust. Soc Am., in press (2004).

  19. Determination of the neutral oxygen atom density in a plasma reactor loaded with metal samples

    NASA Astrophysics Data System (ADS)

    Mozetic, Miran; Cvelbar, Uros

    2009-08-01

    The density of neutral oxygen atoms was determined during processing of metal samples in a plasma reactor. The reactor was a Pyrex tube with an inner diameter of 11 cm and a length of 30 cm. Plasma was created by an inductively coupled radiofrequency generator operating at a frequency of 27.12 MHz and output power up to 500 W. The O density was measured at the edge of the glass tube with a copper fiber optics catalytic probe. The O atom density in the empty tube depended on pressure and was between 4 and 7 × 1021 m-3. The maximum O density was at a pressure of about 150 Pa, while the dissociation fraction of O2 molecules was maximal at the lowest pressure and decreased with increasing pressure. At about 300 Pa it dropped below 10%. The measurements were repeated in the chamber loaded with different metallic samples. In these cases, the density of oxygen atoms was lower than that in the empty chamber. The results were explained by a drain of O atoms caused by heterogeneous recombination on the samples.

  20. Improving the efficiency of an Er:YAG laser on enamel and dentin.

    PubMed

    Rizcalla, Nicolas; Bader, Carl; Bortolotto, Tissiana; Krejci, Ivo

    2012-02-01

    To evaluate the influence of air pressure, water flow rate, and pulse frequency on the removal speed of enamel and dentin as well as on their surface morphology. Twenty-four bovine incisors were horizontally cut in slices. Each sample was mounted on an experimental assembly, allowing precise orientation. Eighteen cavities were prepared, nine in enamel and nine in dentin. Specific parameters for frequency, water flow rate, and air pressure were applied for each experimental group. Three groups were randomly formed according to the air pressure settings. Cavity depth was measured using a digital micrometer gauge, and surface morphology was checked by means of scanning electron microscopy. Data was analyzed with ANOVA and Duncan post hoc test. Irradiation at 25 Hz for enamel and 30 Hz for dentin provided the best ablation rates within this study, but efficiency decreased if the frequency was raised further. Greater tissue ablation was found with water flow rate set to low and dropped with higher values. Air pressure was found to have an interaction with the other settings, since ablation rates varied with different air pressure values. Fine-tuning of all parameters to get a good ablation rate with minimum surface damage seems to be key in achieving optimal efficiency for cavity preparation with an Er:YAG laser.

  1. Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

    NASA Technical Reports Server (NTRS)

    Ellis, Tayera

    2015-01-01

    Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

  2. Measurement of Turbulent Pressure and Temperature Fluctuations in a Gas Turbine Combustor

    NASA Technical Reports Server (NTRS)

    Passaro, Andrea; LaGraff, John E.; Oldfield, Martin L. G.; Biagioni, Leonardo; Moss, Roger W.; Battelle, Ryan T.; Povinelli, Louis A. (Technical Monitor)

    2003-01-01

    The present research concerns the development of high-frequency pressure and temperature probes and related instrumentation capable of performing spectral characterization of unsteady pressure and temperature fluctuations over the 0.05 20 kHz range, at the exit of a gas turbine combustor operating at conditions close to nominal ones for large power generation turbomachinery. The probes used a transient technique pioneered at Oxford University; in order to withstand exposure to the harsh environment the probes were fitted on a rapid injection and cooling system jointly developed by Centrospazio CPR and Syracuse University. The experimental runs were performed on a large industrial test rig being operated by ENEL Produzione. The achieved results clearly show the satisfactory performance provided by this diagnostic tool, even though the poor location of the injection port prevented the tests from yielding more insight of the core flow turbulence characteristics. The pressure and temperature probes survived several dozen injections in the combustor hot jet, while consistently providing the intended high frequency performance. The apparatus was kept connected to the combustor during long duration firings, operating as an unobtrusive, self contained, piggy-back experiment: high frequency flow samplings were remotely recorded at selected moments corresponding to different combustor operating conditions.

  3. Real-time determination of fringe pattern frequencies: An application to pressure measurement

    NASA Astrophysics Data System (ADS)

    Sciammarella, Cesar A.; Piroozan, Parham

    2007-05-01

    Retrieving information in real time from fringe patterns is a topic of a great deal of interest in scientific and engineering applications of optical methods. This paper presents a method for fringe frequency determination based on the capability of neural networks to recognize signals that are similar but not identical to signals used to train the neural network. Sampled patterns are generated by calibration and stored in memory. Incoming patterns are analyzed by a back-propagation neural network at the speed of the recording device, a CCD camera. This method of information retrieval is utilized to measure pressures on a boundary layer flow. The sensor combines optics and electronics to analyze dynamic pressure distributions and to feed information to a control system that is capable to preserve the stability of the flow.

  4. In-Situ Ultra Low Frequency Poroelastic Response of a Natural Macro-Fracture

    NASA Astrophysics Data System (ADS)

    Guglielmi, Y.; Cappa, F.; Rutqvist, J.; Tsang, C.; Gaffet, S.

    2008-12-01

    The seismic visibility of macro-fractures filled with fluids is a central problem in the exploration of thermo- hydro-mechanical and chemical processes that occur in Earth' s subsurface. Most studies have been concerned (1) with cracks of a small size relative to the seismic wavelength (2) with "core-sized" samples of single macro-fractures. In comparison, in-situ studies of macro-fractures are very rare and no real estimate is made of the relevance of this convenient "core-sized" data to in-situ reservoirs in general. In this study, we present a new experimental approach to in-situ characterize mechanical and hydraulic properties of fractures using the innovative HPPP protocol. This protocol allows simultaneous high-frequency (120.2 Hz) sampling of normal displacement and fluid pressure in a borehole intersecting the fracture. We show preliminary results conducted in a single fracture vertically embedded in a carbonate reservoir that contains 3 sets of macro-fractures with an average 2m spacing. Two HPPP probes were set, spaced one meter vertically in the fracture. Two types of ULF seismic sources are applied: a fluid pressure pulse injected in the fracture and a hammer hit at a point located 5m far from the fracture plane. There is a highly non-linear variation of fracture normal displacement-versus- fluid pressure as a function of frequency, the higher the frequency, the lower the displacement spectral amplitude is. The pressure pulse and the hammer hit allow exploring the fracture poroelastic response in the [0 - 3Hz] frequency range. The fracture plays the role of a "low-pass" filter for fluid pressure waves; only a quasi-static pressure signal being registered at the receiver. The displacement wave propagation is more complex resulting in uncoupled quasi-static-pressure-2Hz-deformation signals at the receiver. For low magnitude seismic sources (low amplitude pulse and seismic wave), the fracture natural resonance is amplified resulting in separate signals power spectral peaks. When fluid pressure is enough increased, hydraulic diffusion takes place at frequencies lower than 1.2 Hz. Poroelastic effects related to static hydraulic diffusion and to wave propagation were described separately using a linear elastic model where the fracture was treated as a displacement discontinuity across which stresses are continuous but displacement are discontinuous. It appears that the dynamic fracture normal stiffness at 2 to 3 Hz is a factor of 2.8 higher than the static stiffness although the fracture displays a high hydraulic aperture of 10-4 m. This surprising result is related to a high heterogeneity of the fracture channel network with a large porosity/permeability contrast that does not allow fluid displacement under dynamic loading. The HPPP approach appears as a possibility to in-situ characterize such fractures static to seismic poroelastic heterogeneous properties.

  5. Observation of a superfluid He-3 A- B phase transition in silica aerogel

    PubMed

    Barker; Lee; Polukhina; Osheroff; Hrubesh; Poco

    2000-09-04

    New NMR studies of 3He in high-porosity aerogel reveal a phase transition from an A-like to a B-like phase on cooling. The evidence includes frequency shift and magnetic susceptibility data, and similar behavior is found in two quite different aerogel samples. The A-like phase is stable only very near to T(c) but can be supercooled to below 0.8T(c). This behavior has been seen clearly at 32- and 24-bar pressures, and the presence of negative frequency shifts suggests that an A-like phase exists near T(c) at pressures as low as 12 bars in a magnetic field of 28.4 mT.

  6. Saturation Dip Measurements of High-J Transitions in the v_1+v_3 Band of C_2H_2: Absolute Frequencies and Self-Broadening

    NASA Astrophysics Data System (ADS)

    Sears, Trevor; Twagirayezu, Sylvestre; Hall, Gregory

    2017-06-01

    Saturation dip spectra of acetylene in the v_1 + v_3 band have been obtained for rotational lines with J = 31-37 inclusive, using a diode laser referenced to a frequency comb. The estimated accuracy and precision of the measurements is better than 10 kHz in 194 THz. Data were obtained as a function of sample pressure to investigate the broadening of the saturation features. The observed line shapes are well modeled by convolution of a fixed Gaussian transit-time and varying Lorentzian lifetime broadening, i.e. a Voigt-type profile. The lines exhibit a significantly larger collisional (lifetime) broadening than has been measured in conventional Doppler and pressure-broadened samples at ambient temperatures. The figure shows the fitted Lorentzian width versus sample pressure for P(31). The slope of this plot gives the pressure broadening coefficient, γ_{self} = 9.35(13) MHz/mbar. For comparison, the coefficient derived from conventional Doppler and pressure broadened spectra for this transition is 2.7 MHz/mbar. The sub-Doppler broadening coefficients are all significantly larger than the conventionally measured ones, due to the increased importance of velocity-changing collisions. The measurements therefore give information on the balance between hard phase- or state-changing and large cross-section velocity-changing collisions. Acknowledgments: Work at Brookhaven National Laboratory was carried out under Contract No. DE-SC0012704 with the U.S. Department of Energy, Office of Science, and supported by its Division of Chemical Sciences, Geosciences and Biosciences within the Office of Basic Energy Sciences. J. Molec. Spectrosc. 209, 216-227 (2001) and J. Quant. Spectrosc. Rad. Transf. 76, 237-267 (2003)

  7. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    NASA Astrophysics Data System (ADS)

    Setareh, Salarieh; Davoud, Dorranian

    2013-11-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O2, He, and He/O2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment.

  8. Comparison of Engine/Inlet Distortion Measurements with MEMS and ESP Pressure Sensors

    NASA Technical Reports Server (NTRS)

    Soto, Hector L.; Hernandez, Corey D.

    2004-01-01

    A study of active-flow control in a small-scale boundary layer ingestion inlet was conducted at the NASA Langley Basic Aerodynamic Research Tunnel (BART). Forty MEMS pressure sensors, in a rake style configuration, were used to examine both the mean (DC) and high frequency (AC) components of the total pressure across the inlet/engine interface plane. The mean component was acquired and used to calculate pressure distortion. The AC component was acquired separately, at a high sampling rate, and is used to study the unsteady effects of the active-flow control. An identical total pressure rake, utilizing an Electronically Scanned Pressure (ESP) system, was also used to calculate distortion; a comparison of the results obtained using the two rakes is presented.

  9. Electron-phonon coupling and superconductivity in MgB2 under hydrostatic pressure.

    NASA Astrophysics Data System (ADS)

    Quijano, Ramiro; Aguayo, Aaron

    2005-03-01

    We have studied the dynamics and coupling of the E2g phonon mode with the σ-band in MgB2 under pressure using the Frozen Phonon Approximation. The results were obtained by means of first-principles total-energy calculations using the full potential Linearized Augmented Plane Wave (LAPW) method and the Generalized Gradient Approximation (GGA) for the exchange-correlation potential. We present results for the evolution of the anharmonicity and phonon frequency of the E2g mode, the electron-phonon coupling constant, and Tc as a function of hydrostatic pressure in the range 0-40 GPa. We find that the phonon frequency increases monotonically with pressure, but the the anharmonicity, the electron-phonon coupling and Tc decreases with pressure. We have obtained a very good agreement between the calculated Tc(P) and the experimental data available in the literature, in particular with the experimental data corresponding to monocystalline samples. This work was supported by Consejo Nacional de Ciencia y Tecnolog'ia (CONACYT, M'exico) under Grant No. 43830-F.

  10. Experimental development of low-frequency shear modulus and attenuation measurements in mated rock fractures: Shear mechanics due to asperity contact area changes with normal stress

    DOE PAGES

    Saltiel, Seth; Selvadurai, Paul A.; Bonner, Brian P.; ...

    2017-02-16

    Reservoir core measurements can help guide seismic monitoring of fluid-induced pressure variations in tight fractured reservoirs including those targeted for supercritical CO 2 injection. We present the first seismic-frequency ‘room-dry’ measurements of fracture specific shear stiffness, using artificially fractured standard granite samples with different degrees of mating, a well-mated tensile fracture from a dolomite reservoir core, as well as simple roughened polymethyl methacrylate (PMMA) surfaces. We have adapted a low-frequency (0.01 to 100 Hz) shear modulus and attenuation apparatus to explore the seismic signature of fractures and understand the mechanics of asperity contacts under a range of normal stress conditions.more » Our instrument is unique in its ability to measure at low normal stresses (0.5 – 20 MPa), simulating 'open' fractures in shallow or high fluid pressure reservoirs. The accuracy of our instrument is demonstrated by calibration and comparison to ultrasonic measurements and low-frequency direct shear measurements of intact samples from the literature. Pressure sensitive film was used to measure real contact area of the fracture surfaces. The fractured shear modulus for the majority of the samples shows an exponential dependence on real contact area. A simple numerical model, with one bonded circular asperity, predicts this behavior and matches the data for the simple PMMA surfaces. The rock surfaces reach their intact moduli at lower contact area than the model predicts, likely due to more complex geometry. Lastly, we apply our results to a Linear-Slip Interface Model to estimate reflection coefficients and calculate shear wave time delays due to the lower wave velocities through the fractured zone. We find that cross-well surveys could detect even well-mated hard rock fractures assuming the availability of high repeatability acquisition systems.« less

  11. Experimental development of low-frequency shear modulus and attenuation measurements in mated rock fractures: Shear mechanics due to asperity contact area changes with normal stress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saltiel, Seth; Selvadurai, Paul A.; Bonner, Brian P.

    Reservoir core measurements can help guide seismic monitoring of fluid-induced pressure variations in tight fractured reservoirs including those targeted for supercritical CO 2 injection. We present the first seismic-frequency ‘room-dry’ measurements of fracture specific shear stiffness, using artificially fractured standard granite samples with different degrees of mating, a well-mated tensile fracture from a dolomite reservoir core, as well as simple roughened polymethyl methacrylate (PMMA) surfaces. We have adapted a low-frequency (0.01 to 100 Hz) shear modulus and attenuation apparatus to explore the seismic signature of fractures and understand the mechanics of asperity contacts under a range of normal stress conditions.more » Our instrument is unique in its ability to measure at low normal stresses (0.5 – 20 MPa), simulating 'open' fractures in shallow or high fluid pressure reservoirs. The accuracy of our instrument is demonstrated by calibration and comparison to ultrasonic measurements and low-frequency direct shear measurements of intact samples from the literature. Pressure sensitive film was used to measure real contact area of the fracture surfaces. The fractured shear modulus for the majority of the samples shows an exponential dependence on real contact area. A simple numerical model, with one bonded circular asperity, predicts this behavior and matches the data for the simple PMMA surfaces. The rock surfaces reach their intact moduli at lower contact area than the model predicts, likely due to more complex geometry. Lastly, we apply our results to a Linear-Slip Interface Model to estimate reflection coefficients and calculate shear wave time delays due to the lower wave velocities through the fractured zone. We find that cross-well surveys could detect even well-mated hard rock fractures assuming the availability of high repeatability acquisition systems.« less

  12. Dynamics of acoustically levitated disk samples.

    PubMed

    Xie, W J; Wei, B

    2004-10-01

    The acoustic levitation force on disk samples and the dynamics of large water drops in a planar standing wave are studied by solving the acoustic scattering problem through incorporating the boundary element method. The dependence of levitation force amplitude on the equivalent radius R of disks deviates seriously from the R3 law predicted by King's theory, and a larger force can be obtained for thin disks. When the disk aspect ratio gamma is larger than a critical value gamma(*) ( approximately 1.9 ) and the disk radius a is smaller than the critical value a(*) (gamma) , the levitation force per unit volume of the sample will increase with the enlargement of the disk. The acoustic levitation force on thin-disk samples ( gamma

  13. Dynamics of acoustically levitated disk samples

    NASA Astrophysics Data System (ADS)

    Xie, W. J.; Wei, B.

    2004-10-01

    The acoustic levitation force on disk samples and the dynamics of large water drops in a planar standing wave are studied by solving the acoustic scattering problem through incorporating the boundary element method. The dependence of levitation force amplitude on the equivalent radius R of disks deviates seriously from the R3 law predicted by King’s theory, and a larger force can be obtained for thin disks. When the disk aspect ratio γ is larger than a critical value γ*(≈1.9) and the disk radius a is smaller than the critical value a*(γ) , the levitation force per unit volume of the sample will increase with the enlargement of the disk. The acoustic levitation force on thin-disk samples (γ⩽γ*) can be formulated by the shape factor f(γ,a) when a⩽a*(γ) . It is found experimentally that a necessary condition of the acoustic field for stable levitation of a large water drop is to adjust the reflector-emitter interval H slightly above the resonant interval Hn . The simulation shows that the drop is flattened and the central parts of its top and bottom surface become concave with the increase of sound pressure level, which agrees with the experimental observation. The main frequencies of the shape oscillation under different sound pressures are slightly larger than the Rayleigh frequency because of the large shape deformation. The simulated translational frequencies of the vertical vibration under normal gravity condition agree with the theoretical analysis.

  14. Determination of rock properties by low-frequency AC electrokinetics

    NASA Astrophysics Data System (ADS)

    Pengra, David B.; Xi Li, Sidney; Wong, Po-Zen

    1999-12-01

    In brine-saturated rock the existence of a mobile space charge at the fluid/solid interface leads to the electrokinetic phenomena of electroosmotic pressure and streaming potential. The coupling coefficients of these electrokinetic effects, when combined with the conductivity of the brine-saturated rock, determine the brine permeability of rock exactly. A sensitive low-frequency AC technique has been used to measure electrokinetic response of a collection of eight rock and four glass bead samples saturated with NaCl brine as a function of salt concentration (fluid conductivity of 0.5 to 6.38 S/m); the response of four of the original 12 samples has also been measured as a function of temperature from 0° to 50°C. All data verify the predicted permeability relationship. Additionally, the frequency response of the electroosmotic pressure signal alone can also be used to determine the permeability, given knowledge of experimental parameters. The concentration and temperature dependence of electroosmosis and streaming potential is found to mostly conform to the predictions of a simple model based on the Helmholtz-Smoluchowski equation, the Stern model of the electrochemical double layer, and an elementary theory of ionic conduction.

  15. Deviation of tracheal pressure from airway opening pressure during high-frequency oscillatory ventilation in a porcine lung model.

    PubMed

    Johannes, Amélie; Zollhoefer, Bernd; Eujen, Ulrike; Kredel, Markus; Rauch, Stefan; Roewer, Norbert; Muellenbach, Ralf M

    2013-04-01

    Oxygenation during high-frequency oscillatory ventilation is secured by a high level of mean airway pressure. Our objective was to identify a pressure difference between the airway opening of the respiratory circuit and the trachea during application of different oscillatory frequencies. Six female Pietrain pigs (57.1 ± 3.6 kg) were first ventilated in a conventional mechanical ventilation mode. Subsequently, the animals were switched to high-frequency oscillatory ventilation by setting mean airway opening pressure 5 cmH(2)O above the one measured during controlled mechanical ventilation. Measurements at the airway opening and at tracheal levels were performed in healthy lungs and after induction of acute lung injury by surfactant depletion. During high-frequency oscillatory ventilation, the airway opening pressure was set at a constant level. The pressure amplitude was fixed at 90 cmH(2)O. Starting from an oscillatory frequency of 3 Hz, the frequency was increased in steps of 3 Hz to 15 Hz and then decreased accordingly. At each frequency, measurements were performed in the trachea through a side-lumen of the endotracheal tube and the airway opening pressure was recorded. The pressure difference was calculated. At every oscillatory frequency, a pressure loss towards the trachea could be shown. This pressure difference increased with higher oscillatory frequencies (3 Hz 2.2 ± 2.1 cmH(2)O vs. 15 Hz 7.5 ± 1.8 cmH(2)O). The results for healthy and injured lungs were similar. Tracheal pressures decreased with higher oscillatory frequencies. This may lead to pulmonary derecruitment. This has to be taken into consideration when increasing oscillatory frequencies and differentiated pressure settings are mandatory.

  16. Incidence and Determinants of Port Occlusions in Cancer Outpatients: A Prospective Cohort Study.

    PubMed

    Milani, Alessandra; Mazzocco, Ketti; Gandini, Sara; Pravettoni, Gabriella; Libutti, Livio; Zencovich, Claudia; Sbriglia, Ada; Pari, Chiara; Magon, Giorgio; Saiani, Luisa

    Normal saline is considered a safe alternative for heparin as a locking solution in totally implantable venous access devices. The incidence rate of partial occlusion with the use of normal saline (easy injection, impossible aspiration) is estimated at 4%. The aim of this study was to investigate determinants of partial occlusions with the use of normal saline solution and the maintenance of positive pressure in the catheter. We enrolled 218 patients with different solid tumors who underwent pharmacologic treatment through the port with different frequencies: from once every week to at least once every month. The port was flushed with normal saline solution keeping a positive pressure in the catheter. We performed 4111 observations and documented normal port functioning in 99% of observations (n = 4057) and partial occlusions in 1% of observations (n = 54). Partial occlusions were significantly associated with frequency of port flushing (P < .05), chemotherapy (P < .001), and blood sample collection (P < .001). The use of positive pressure in addition to normal saline reduces the incidence rate of partial occlusions. The type of treatment, blood sample collection, and treatment schedule are important determinants of partial occlusions. Nurses play a key role in maintaining a functioning port using positive pressure during the flushing techniques. Certain risk factors must be monitored to prevent partial occlusions, and certain patients are more likely to present with port-related problems.

  17. High pressure Raman study of type-I collagen.

    PubMed

    Paschou, Amalia Maria; Katsikini, Maria; Christofilos, Dimitrios; Arvanitidis, John; Ves, Sotirios

    2018-05-18

    The high pressure response of type-I collagen from bovine Achilles tendon is investigated with micro-Raman spectroscopy. Fluorinert ™ and methanol-ethanol mixtures were used as pressure transmitting media (PTM) in a diamond anvil cell. The Raman spectrum of collagen is dominated by three bands centred at approximately 1450, 1660 and 2930 cm -1 , attributed to C-H deformation, C=O stretching of the peptide bond (amide-I band) and C-H stretching modes, respectively. Upon pressure increase, using Fluorinert ™ as PTM, a shift towards higher frequencies of the C-H stretching and deformation peaks is observed. Contrary, the amide-I band peaks are shifted to lower frequencies with moderate pressure slopes. On the other hand, by using the alcohol mixture as PTM, the amide-I band exhibits more pronounced C=O bond softening, deduced from the shift to lower frequencies, suggesting a strengthening of the hydrogen bonds between glycine and proline residues of different collagen chains due to the presence of the polar alcohol molecules. Furthermore, some of the peaks exhibit abrupt changes in their pressure slopes at approximately 2 GPa, implying a variation in the compressibility of the collagen fibres. This could be attributed to a pitch change from 10/3 to 7/2, sliding of the tropocollagen molecules, twisting variation at the molecular level and/or elimination of the D-gaps induced by kink compression. All spectral changes are reversible upon pressure release, which indicates that denaturation has not taken place. Finally, a minor lipid phase contamination was detected in some sample spots. Its pressure response is also monitored. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Association between ascites and primary hyperfibrinolysis: A cohort study in 210 dogs.

    PubMed

    Zoia, Andrea; Drigo, Michele; Simioni, Paolo; Caldin, Marco; Piek, Christine J

    2017-05-01

    Coagulation profiles were determined in 70 dogs with ascites, 70 healthy control dogs and 70 sick control dogs without ascites. Dogs with ascites were divided into four sub-groups based on the pathophysiology of fluid formation. Coagulation profile, serum C-reactive protein and frequency of discordant plasma fibrin-fibrinogen degradation products and D-dimer assay results, suggesting primary hyperfibrinolysis, were compared between groups. Within the ascites group, 10 samples of ascitic fluid were transudates due to decreased osmotic pressure, 18 were transudates due to increased hydrostatic pressure, 13 were exudates and 29 were haemorrhagic. Plasma fibrinogen concentrations were significantly lower in dogs with ascites compared to sick dogs without ascites. Activated partial thromboplastin time, prothrombin time, plasma concentrations of fibrin-fibrinogen degradation products and D-dimers, and frequency of primary hyperfibrinolysis, were significantly higher for dogs with ascites compared to both control groups. There was no significant difference in platelet count between groups. The frequency of primary hyperfibrinolysis was highest in dogs with transudative ascites due to increased hydrostatic pressure. Serum C-reactive protein was significantly higher in dogs with ascites compared to both control groups, and significantly and positively correlated with plasma D-dimers. In conclusion, dogs with ascites have an increased frequency of primary hyperfibrinolysis, especially with ascites secondary to increased hydrostatic pressure. The increased inflammation present in these dogs may have activated haemostasis in some cases, explaining the higher plasma D-dimers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Standard-free Pressure Measurement by Ultrasonic Interferometry in a Multi-Anvil Device

    NASA Astrophysics Data System (ADS)

    Mueller, H. J.; Lathe, C.; Schilling, F. R.; Lauterjung, J.

    2002-12-01

    A key question to all high pressure research arises from the reliability of pressure standards. There is some indication and discussion of an uncertainty of 10-20% for higher pressures in all standards. Simultaneous and independent investigation of the dynamical (ultrasonic interferometry of elastic wave velocities) and static (XRD-measurement of the pressure-induced volume decline) compressibility on a sample reveal the possibility of a standard-free pressure calibration (see Getting, 1998) and, consequently an absolute pressure measurement. Ultrasonic interferometry is used to measure velocities of elastic compressional and shear waves in the multi-anvil high pressure device MAX80 at HASYLAB Hamburg enabling simultaneous XRD and ultrasonic experiments. Two of the six anvils were equipped with overtone polished lithium niobate transducers of 33.3 MHz natural frequency, for generation and detection of ultrasonic waves with a frequency sweep between 5 and 55 MHz. Different buffer - reflector combinations were tested to optimize the critical interference between both sample echoes. NaCl powder of 99.5 % purity (analytical grade by Merck) was used as starting material for manufacturing the samples used as pressure calibrant after Decker (1971). The medium grain size was 50 μm. The powder was pressed to a crude sample cylinder of 10 mm diameter and a length of 20 mm using a load of 6 tons resulting in an effective pressure of 0.25 to 0.3 GPa. The millimeter sized samples (diameter 2.4 mm and 1.6 mm length for 6 mm anvil truncation and diameter 3.1 mm and 1.1 mm length for 3.5 mm anvil truncation) for the high pressure experiments were shaped with a high-precision (+/- 0.5 μm) cylindrical grinding machine and polished at the front faces. From the ultrasonic wave velocity data we calculated the compressibility of NaCl. This requires in situ density data. Therefore the sample deformation during the high pressure experiments was analyzed in detail and the results were compared with models published by different authors. The experimental results measured with different set-ups under different pressure conditions were compared with EoS-data derived from static compression experiments up to 5 GPa (Bridgman, 1940) and up to 30 GPa (Holland and Ahrens, 1998; Birch, 1986) using experimental data from Boehler and Kennedy (1980) and Fritz et al. (1971). At 1.2 GPa and 5.3 GPa the results of static compression data exactly correspond to our velocity-based data, polynomial-fitted up to the power of 7. In the range between 2 and 4 GPa our dynamical data have 1.5 - 3 % higher values. Furthermore the pressure revealed according to Decker (1971) is in accordance to our standard-free pressure calibration within the uncertainty of the experiment. Birch, F., J., Geophys. Res., 91, 4,949-4,954, (1986).\\Boehler, R., Kennedy, G.C., J. Phys. Chem. Solids, 41, 517-523, (1980). Bridgman, P.W., Physical Review, 57, 237-239, (1940).\\Decker, D.L., J. Appl. Physics, 42, 3,239-3,244, (1971).\\Fritz, J.N., Marsh, S.P., Carter, W.J., McQueen, R.G., NBS Spec. Publ., E.C. Lloyd ed., 326, 201-208, (1971). Getting, I.C., Eos, 79, F830, (1998).\\Holland, K.G., Ahrens, T.H., Geophys. Mon. 101, Manghnani, M.H. and Yagi, T. eds., 335-355, (1998).

  20. Remote tire pressure sensing technique

    NASA Technical Reports Server (NTRS)

    Robinson, Howard H. (Inventor); Mcginnis, Timothy A. (Inventor); Daugherty, Robert H. (Inventor)

    1993-01-01

    A remote tire pressure sensing technique is provided which uses vibration frequency to determine tire pressure. A vibration frequency measuring device is attached to the external surface of a tire which is then struck with an object, causing the tire to vibrate. The frequency measuring device measures the vibrations and converts the vibrations into corresponding electrical impulses. The electrical impulses are then fed into the frequency analyzing system which uses the electrical impulses to determine the relative peaks of the vibration frequencies as detected by the frequency measuring device. The measured vibration frequency peaks are then compared to predetermined data describing the location of vibration frequency peaks for a given pressure, thereby determining the air pressure of the tire.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Jesse S.; Sinogeikin, Stanislav V.; Lin, Chuanlong

    Complementary advances in high pressure research apparatus and techniques make it possible to carry out time-resolved high pressure research using what would customarily be considered static high pressure apparatus. This work specifically explores time-resolved high pressure x-ray diffraction with rapid compression and/or decompression of a sample in a diamond anvil cell. Key aspects of the synchrotron beamline and ancillary equipment are presented, including source considerations, rapid (de)compression apparatus, high frequency imaging detectors, and software suitable for processing large volumes of data. A number of examples are presented, including fast equation of state measurements, compression rate dependent synthesis of metastable statesmore » in silicon and germanium, and ultrahigh compression rates using a piezoelectric driven diamond anvil cell.« less

  2. Payload and Components Real-Time Automated Test System (PACRATS), Data Acquisition of Leak Rate and Pressure Data Test Procedure

    NASA Technical Reports Server (NTRS)

    Rinehart, Maegan L.

    2011-01-01

    The purpose of this activity is to provide the Mechanical Components Test Facility (MCTF) with the capability to obtain electronic leak test and proof pressure data, Payload and Components Real-time Automated Test System (PACRATS) data acquisition software will be utilized to display real-time data. It will record leak rates and pressure/vacuum level(s) simultaneously. This added functionality will provide electronic leak test and pressure data at specified sampling frequencies. Electronically stored data will provide ES61 with increased data security, analysis, and accuracy. The tasks performed in this procedure are to verify PACRATS only, and are not intended to provide verifications for MCTF equipment.

  3. Laboratory Investigation of the Effect of Water-Saturation on Seismic Wave Dispersion in Carbonates

    NASA Astrophysics Data System (ADS)

    Li, W.; Pyrak-Nolte, L. J.

    2009-12-01

    In subsurface rock, fluid content changes with time through natural causes or because of human interactions, such as extraction or sequestration of fluids. The ability to monitor, seismically, fluid migration in the subsurface requires an understanding of the effects that the degree of saturation and spatial distribution of fluids have on wave propagation in rock. In this study, we find that the seismic dispersion of a dry carbonate rock can be masked by saturating the sample. We used a laboratory mini-seismic array to monitor fluid invasion and withdrawal in a carbonate rock with fabric-controlled layering. Experiments were performed on prismatic samples of Austin Chalk measuring 50mm x 50mm x 100mm. The epoxy-sealed samples contained an inlet and an outlet port to enable fluid invasion/withdrawal along the long axis of the sample. Water was infused and withdrawn from the sample at a rate of 1ml/hr. The mini-seismic array consisted of a set of 12 piezoelectric contact transducers, each with a central frequency 1.0 MHz. Three compressional wave source-receiver pairs and three shear wave source-receiver pairs were used to probe along the length of the sample prior to invasion and during invasion and withdrawal of water from the sample. A pressure transducer was used to record the fluid pressure simultaneously with the full transmitted wave forms every 15-30 minutes. A wavelet analysis determined the effect of fluid invasion on velocity dispersion. We observed that the compressional wave dispersion was more sensitive to changes in saturation than the shear wave dispersion. When the sample was unsaturated, the high frequency components of the compressional wave (1.2MHz to 2MHz) had lower velocities (~ 2750m/s) than the low frequency components, which decrease monotonically from 2890 m/s for 0.2MHz to 1.2 MHz. As water infused the sample, the dispersion weakened. When the sample as fully saturated, the compressional wave velocity was frequency independent. The functional form of the dependence of the shear wave velocity on frequency is relatively constant with fluid saturation, but the magnitude of the velocity decreased (~35 m/s) with increasing saturation. From theoretical calculations, the shear modulus increased during water invasion and was independent of frequency. However, the changes in the Young’s modulus with water invasion depended on the frequency of observation. When 46.5ml was infused into the sample, the Young’s modulus interpreted from the high-frequency components (wavelength from 1.43mm to 2.4mm) increased 70%, while the modulus from the low-frequency components (wavelengths vary from 1.4cm to 3.4mm) increased between 20% and 55%. Interpreting seismic data to determine fluid saturation in rock with fabric-controlled layering requires an understanding of the seismic dispersion properties of the rock in addition to the ability of fluids on alter or mask the dispersion. Acknowledgments: The authors wish to acknowledge support of this work by the Geosciences Research Program, Office of Basic Energy Sciences US Department of Energy (DEFG02-97ER14785 08), by Exxon Mobil Upstream Research Company and the GeoMathematical Imaging Group at Purdue University.

  4. Short communication: Is consumption of a cheese rich in angiotensin-converting enzyme-inhibiting peptides, such as the Norwegian cheese Gamalost, associated with reduced blood pressure?

    PubMed

    Nilsen, R; Pripp, A H; Høstmark, A T; Haug, A; Skeie, S

    2014-05-01

    Epidemiological and clinical studies have shown that angiotensin-converting enzyme (ACE)-inhibiting peptides derived from dairy products may decrease blood pressure. These peptides have been identified in many cheeses, and Gamalost, a traditional Norwegian cheese, is particularly rich in these peptides. The aim of this cross-sectional study was to examine whether frequency of Gamalost intake was associated with blood pressure in a Norwegian population sample. Blood pressure and other clinical measurements, including the factors of metabolic syndrome, were obtained from 168 participants (56% female, mean age = 51 yr) who completed a questionnaire about dietary habits and other health-related factors. Mean Gamalost intake was 2 servings per week. The prevalence of hypertension was 23.8% in the population, with mean systolic and diastolic blood pressures of 128 and 78 mmHg, respectively. Intake of Gamalost was inversely associated with systolic blood pressure. Each increase in frequency unit of Gamalost intake corresponded to a reduction in systolic blood pressure of 0.72 mmHg, after controlling for sex, age, education, waist circumference, physical activity, smoking status, and dairy food intake. Results from this study indicate that consumption of Gamalost (or other foods rich in ACE-inhibiting peptides) may reduce blood pressure. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. μ+SR Study on Layered Chromium Perovskites: Srn+1CrnO3n+1 (n = 1-3)

    NASA Astrophysics Data System (ADS)

    Nozaki, Hiroshi; Sakurai, Hiroya; Umegaki, Izumi; Ansaldo, Eduardo J.; Morris, Gerald D.; Hitti, Bassam; Arseneau, Donald J.; Andreica, Daniel; Amato, Alex; Månsson, Martin; Sugiyama, Jun

    The magnetic nature of layered chromium perovskites, Srn+1CrnO3n+1 (n = 1-3) was studied by μ+SR using powder samples prepared by a high pressure synthesis technique. According to the weak transverse field measurements, each sample entered a magnetically ordered state below 110, 200, and 90 K for the n = 1, 2, and 3 samples, respectively. Zero field (ZF) spectra below the transition temperature exhibited a clear oscillation due to the formation of quasi-static magnetic order. The Fourier transform frequency-spectrum for the ZF time-spectrum indicated the existence of the multiple oscillation components. The frequencies for the multiple oscillatory signals showed a complex temperature dependence, implying the occurrence of structural change/transitions below TN.

  6. Modeling dynamic acousto-elastic testing experiments: validation and perspectives.

    PubMed

    Gliozzi, A S; Scalerandi, M

    2014-10-01

    Materials possessing micro-inhomogeneities often display a nonlinear response to mechanical solicitations, which is sensitive to the confining pressure acting on the sample. Dynamic acoustoelastic testing allows measurement of the instantaneous variations in the elastic modulus due to the change of the dynamic pressure induced by a low-frequency wave. This paper shows that a Preisach-Mayergoyz space based hysteretic multi-state elastic model provides an explanation for experimental observations in consolidated granular media and predicts memory and nonlinear effects comparable to those measured in rocks.

  7. High-pressure behavior of amorphous selenium from ultrasonic measurements and Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    He, Z.; Wang, Z. G.; Zhu, H. Y.; Liu, X. R.; Peng, J. P.; Hong, S. M.

    2014-07-01

    The high-pressure behavior of melt-quenched amorphous selenium (a-Se) has been investigated via ultrasonic measurements and Raman scattering at room temperature. The ultrasonic measurements were conducted on a-Se in a multi-anvil apparatus with two different sample assemblies at pressures of up to 4.5 and 4.8 GPa. We discovered that similar kinks occur in the slopes of the pressure dependence characteristics of the travel time and the sound velocity in both shear and longitudinal waves in the 2.0-2.5 GPa range. These kinks are independent of the sample assemblies, indicating an intrinsic transformation of the a-Se. Additionally, we deduced the pressure-volume relationship of a-Se from the sound velocity characteristics using the Birch-Murnaghan equation of state, and the results agreed well with those of previous reports. In situ high-pressure Raman scattering measurements of a-Se were conducted in a diamond anvil cell with an 830 nm excitation line up to a pressure of 4.3 GPa. We found that the characteristic band of a-Se at ˜250 cm-1 experienced a smooth shift to a lower frequency with pressure, but a sharp slope change in the band intensity versus pressure occurred near 2.5 GPa. The results of X-ray diffraction and differential scanning calorimetry measurements indicate that the samples remain in their amorphous states after decompression. Thus, we proposed that the abnormal compression behavior of a-Se in the 2.0-2.5 GPa range can be attributed to pressure-induced local atomic reconfiguration, implying an amorphous-amorphous transition of the elementary selenium.

  8. Intravenous cannulation of adolescents does not affect the modulation of autonomic tone assessed by heart rate and blood pressure variability.

    PubMed

    Stewart, J M

    2000-02-01

    Invasive arterial monitoring alters autonomic tone. The effects of intravenous (i.v.) insertion are less clear. The author assessed the effects of i.v. insertion on autonomic activity in patients aged 11 to 19 years prior to head-up tilt by measuring heart rate, blood pressure, heart rate variability, blood pressure variability, and baroreceptor gain before and after i.v. insertion with continuous electrocardiography and arterial tonometry in patients with orthostatic tachycardia syndrome (OTS, N = 21), in patients who experienced simple fainting (N = 14), and in normal control subjects (N = 6). Five-minute samples were collected after 30 minutes supine. Fifteen minutes after i.v. insertion, data were collected again. These 5-minute samples were also collected in a separate control population without i.v. insertion after 30 minutes supine and again 30 minutes later. This population included 12 patients with OTS, 13 patients who experienced simple fainting, and 6 normal control subjects. Heart rate variability included the mean RR, the standard deviation of the RR interval (SDNN), and the root mean square of successive RR differences (RMSSD). Autoregressive spectral modeling was used. Low-frequency power (LFP, 0.04-0.15 Hz), high-frequency power (HFP, 0.15-0.40 Hz), and total power (TP, 0.01-0.40 Hz) were compared. Blood pressure variability included standard deviation of systolic blood pressure, LFP, and HFP. Baroreceptor gain at low frequency and high frequency was calculated from cross-spectral transfer function magnitudes when coherence was greater than 0.5. In patients with OTS, RR (790 +/- 50 msec), SDNN (54 +/- 6 msec), RMSSD (55 +/- 5 msec), LFP (422 +/- 200 ms2/Hz), HFP (846 +/- 400 ms2/Hz), and TP (1550 +/- 320 ms2/Hz) were less than in patients who experienced simple fainting (RR, 940 +/- 50 msec; SDNN, 84 +/- 10 msec; RMSSD, 91 +/- 7 msec; LFP, 880 +/- 342 ms2/Hz; HFP, 1720 +/- 210 ms2/Hz; and TP, 3228 +/- 490 ms2/Hz) or normal control subjects (RR, 920 +/- 30 msec; SDNN, 110 +/- 29 msec; RMSSD, 120 +/- 16 msec; LFP, 1600 +/- 331 ms2/Hz; HFP, 2700 +/- 526 ms2/Hz; and TP, 5400 +/- 1017 ms2/Hz). Blood pressure and blood pressure variability were not different in any group. Standard deviation, LFP, and HFP were, respectively, 5.24 +/- 0.8 mm Hg, 1.2 +/- 0.2, and 1.5 +/- 0.3 for patients with OTS; 4.6 +/- 0.4 mm Hg, 1.2 +/- 0.2, and 1.4 +/- 0.3 for patients who experienced simple fainting; and 5.55 +/- 1.0 mm Hg, 1.4 +/- 0.2, and 1.6 +/- 0.3 for normal control subjects. Baroreceptor gain at low frequency and high frequency in patients with OTS (16 +/- 4 msec/mm Hg, 17 +/- 5) was comparable to that in patients who experienced simple fainting (33 +/- 4, 32 +/- 3) and that in normal control subjects (31 +/- 8, 37 +/- 9). Heart rate variability differed between patients with OTS and patients who experienced simple fainting or normal control subjects, and blood pressure and blood pressure variability were not different, but no parameter changed after i.v. insertion. There were no differences from the groups that did not receive i.v. insertions. Data suggest, at most, a limited effect of i.v. insertion on autonomic function in adolescents.

  9. Preliminary Measurements of the Attenuation Properties of Polycrystalline Water Ice and CO2 Clathrate Hydrates at the Tidal Frequencies of Europa and Enceladus

    NASA Astrophysics Data System (ADS)

    Choukroun, M.; Castillo, J. C.; Young, J. B.; Mielke, R.

    2009-12-01

    We will report measurements of the attenuation properties of polycrystalline water ice and CO2 clathrate hydrates samples obtained in the frequency range 3x10-6 to 10-2 Hz, which encompasses the tidal frequencies of Europa and Enceladus. Previous attenuation measurements obtained on a variety of planetary materials have demonstrated that the mechanisms driving attenuation in the frequency range 10-4 to 1 Hz are controlled by the same parameters controlling the creep properties of these materials: temperature, stress, microstructure (including grain size), and the presence of second-phase impurities. Thus, accurate control and characterization of the microstructure and composition of tested samples are key steps toward the development of empirical relationships describing the mechanical response of these materials. This is the reason why we have invested significant effort in the development of synthesis procedures for the production of our samples. Both water ice and clathrate hydrate samples are grown from H2O ice seeds, which are produced by grinding ice crystals pre-grown at -30°C from pure de-ionized liquid water. A high pressure - low temperature vessel, which achieves pressures up to 200 bars and temperatures within the range -50 - +50 °C, is used for the growth of clathrate hydrates. These are synthesized by reaction of ice seeds with CO2 at temperatures close to the melting point of ice in order to improve reaction kinetics. Characterization of the samples composition and microstructure is carried out via crossed-polarized cryo-microscopic observations, and via imaging with a Scanning Electron Microprobe equipped with a liquid - nitrogen cooled stage (CryoSEM). The Energy Dispersive Spectrometer capability of the SEM provides elemental composition for verification of the purity of the samples. For clathrate hydrates, Raman microspectroscopy is also used to ensure the homogeneity of sample composition. We will show that the grain size of the ice seeds is not affected by the transformation into clathrate hydrates. However, the sub-grain structure obviously undergoes significant changes, which might be reflected in the mechanical behavior. In order to remove microporosity, a compaction system has been implemented, which consists to the application of high pressures under vacuum and at very low temperatures. We will show the result of compaction experiments in terms of residual porosity and microstructure evolution. We will also present initial measurements on the attenuation properties of polycrystalline water ice and CO2 clathrate hydrates at the stress conditions and tidal frequencies approaching those of icy satellites such as Europa and Enceladus. Acknowledgements: We gratefully acknowledge C. McCarthy and H. Engelhardt for technical advise and support. MC is supported by a NASA Postdoctoral Fellowship, administered by Oak Ridge Associated Universities. This work has been conducted at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2009, California Institute of Technology. Government sponsorship acknowledged.

  10. Experimental methodology for turbocompressor in-duct noise evaluation based on beamforming wave decomposition

    NASA Astrophysics Data System (ADS)

    Torregrosa, A. J.; Broatch, A.; Margot, X.; García-Tíscar, J.

    2016-08-01

    An experimental methodology is proposed to assess the noise emission of centrifugal turbocompressors like those of automotive turbochargers. A step-by-step procedure is detailed, starting from the theoretical considerations of sound measurement in flow ducts and examining specific experimental setup guidelines and signal processing routines. Special care is taken regarding some limiting factors that adversely affect the measuring of sound intensity in ducts, namely calibration, sensor placement and frequency ranges and restrictions. In order to provide illustrative examples of the proposed techniques and results, the methodology has been applied to the acoustic evaluation of a small automotive turbocharger in a flow bench. Samples of raw pressure spectra, decomposed pressure waves, calibration results, accurate surge characterization and final compressor noise maps and estimated spectrograms are provided. The analysis of selected frequency bands successfully shows how different, known noise phenomena of particular interest such as mid-frequency "whoosh noise" and low-frequency surge onset are correlated with operating conditions of the turbocharger. Comparison against external inlet orifice intensity measurements shows good correlation and improvement with respect to alternative wave decomposition techniques.

  11. Measurements of Regolith Simulant Thermal Conductivity Under Asteroid and Mars Surface Conditions

    NASA Astrophysics Data System (ADS)

    Ryan, A. J.; Christensen, P. R.

    2017-12-01

    Laboratory measurements have been necessary to interpret thermal data of planetary surfaces for decades. We present a novel radiometric laboratory method to determine temperature-dependent thermal conductivity of complex regolith simulants under rough to high vacuum and across a wide range of temperatures. This method relies on radiometric temperature measurements instead of contact measurements, eliminating the need to disturb the sample with thermal probes. We intend to determine the conductivity of grains that are up to 2 cm in diameter and to parameterize the effects of angularity, sorting, layering, composition, and eventually cementation. We present the experimental data and model results for a suite of samples that were selected to isolate and address regolith physical parameters that affect bulk conductivity. Spherical glass beads of various sizes were used to measure the effect of size frequency distribution. Spherical beads of polypropylene and well-rounded quartz sand have respectively lower and higher solid phase thermal conductivities than the glass beads and thus provide the opportunity to test the sensitivity of bulk conductivity to differences in solid phase conductivity. Gas pressure in our asteroid experimental chambers is held at 10^-6 torr, which is sufficient to negate gas thermal conduction in even our coarsest of samples. On Mars, the atmospheric pressure is such that the mean free path of the gas molecules is comparable to the pore size for many regolith particulates. Thus, subtle variations in pore size and/or atmospheric pressure can produce large changes in bulk regolith conductivity. For each sample measured in our martian environmental chamber, we repeat thermal measurement runs at multiple pressures to observe this behavior. Finally, we present conductivity measurements of angular basaltic simulant that is physically analogous to sand and gravel that may be present on Bennu. This simulant was used for OSIRIS-REx TAGSAM Sample Return Arm engineering tests. We measure the original size frequency distribution as well as several sorted size fractions. These results will support the efforts of the OSIRIS-REx team in selecting a site on asteroid Bennu that is safe for the spacecraft and meets grain size requirements for sampling.

  12. Dependence of thresholds for pulmonary capillary hemorrhage on diagnostic ultrasound frequency.

    PubMed

    Miller, Douglas L; Dou, Chunyan; Raghavendran, Krishnan

    2015-06-01

    Pulmonary ultrasound examination has become routine for diagnosis in many clinical and point-of-care medical settings. However, the phenomenon of pulmonary capillary hemorrhage (PCH) induction during diagnostic ultrasound imaging presents a poorly understood risk factor. PCH was observed in anesthetized rats exposed to 1.5-, 4.5- and 12.0-MHz diagnostic ultrasound to investigate the frequency dependence of PCH thresholds. PCH was detected in the ultrasound images as growing comet tail artifacts and was assessed using photographs of the surface of excised lungs. Previous photographs acquired after exposure to 7.6-MHz diagnostic ultrasound were included for analysis. In addition, at each frequency we measured dosimetric parameters, including peak rarefactional pressure amplitude and spatial peak, pulse average intensity attenuated by rat chest wall samples. Peak rarefactional pressure amplitude thresholds determined at each frequency, based on the proportion of PCH in groups of five rats, were 1.03 ± 0.02, 1.28 ± 0.14, 1.18 ± 0.12 and 1.36 ± 0.15 MPa at 1.5, 4.5, 7.6 and 12.0 MHz, respectively. Although the PCH lesions decreased in size with increasing ultrasonic frequency, owing to the smaller beam widths and scan lengths, the peak rarefactional pressure amplitude thresholds remained approximately constant. This dependence was different from that of the mechanical index, which indicates a need for a specific dosimetric parameter for safety guidance in pulmonary ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Measurement of the resistivity of porous materials with an alternating air-flow method.

    PubMed

    Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A

    2011-02-01

    Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.

  14. Quantification of peripheral and central blood pressure variability using a time-frequency method.

    PubMed

    Kouchaki, Z; Butlin, M; Qasem, A; Avolio, A P

    2016-08-01

    Systolic blood pressure variability (BPV) is associated with cardiovascular events. As the beat-to-beat variation of blood pressure is due to interaction of several cardiovascular control systems operating with different response times, assessment of BPV by spectral analysis using the continuous measurement of arterial pressure in the finger is used to differentiate the contribution of these systems in regulating blood pressure. However, as baroreceptors are centrally located, this study considered applying a continuous aortic pressure signal estimated noninvasively from finger pressure for assessment of systolic BPV by a time-frequency method using Short Time Fourier Transform (STFT). The average ratio of low frequency and high frequency power band (LF PB /HF PB ) was computed by time-frequency decomposition of peripheral systolic pressure (pSBP) and derived central aortic systolic blood pressure (cSBP) in 30 healthy subjects (25-62 years) as a marker of balance between cardiovascular control systems contributing in low and high frequency blood pressure variability. The results showed that the BPV assessed from finger pressure (pBPV) overestimated the BPV values compared to that assessed from central aortic pressure (cBPV) for identical cardiac cycles (P<;0.001), with the overestimation being greater at higher power.

  15. High-pressure cell for terahertz time-domain spectroscopy.

    PubMed

    Zhang, Wei; Nickel, Daniel; Mittleman, Daniel

    2017-02-06

    We introduce a sample cell that can be used for pressure-dependent terahertz time-domain spectroscopy. Compared with traditional far-IR spectroscopy with a diamond anvil cell, the larger aperture permits measurements down to much lower frequencies as low as 3.3 cm-1 (0.1 THz), giving access to new spectroscopic results. The pressure tuning range reaches up to 34.4 MPa, while the temperature range is from 100 to 473 K. With this large range of tuning parameters, we are able to map out phase diagrams of materials based on their THz spectrum, as well as to track the changing of the THz spectrum within a single phase as a function of temperature and pressure. Pressure-dependent THz-TDS results for nitrogen and R-camphor are shown as an example.

  16. Cycom 977-2 Composite Material: Impact Test Results

    NASA Technical Reports Server (NTRS)

    Engel, Carl D.; Herald, Stephen; Watkins, Casey

    2005-01-01

    The reaction frequency data from 13A testing by MSFC and WSTF appear well behaved for the sample number used by each and exhibit the same type of energy level dependency. The reaction frequency shift in energy level is unexplained at this time. All the 13A data suggest that only a small amount of material is consumed when reactions take place. At ambient pressure, most of not all reactions are quenched as indicated by the small mass loss. As test pressure is increased in LOX using 13B results. Cycom does not support initiation of reactions or propagations of reactions in GOX at 100 psis based on tests at MSFC and WSTF at 72 ft-lb impact energy. No batch effect was identified in LOX or GOX.

  17. Application of Terahertz Attenuated Total Reflection Spectroscopy to Detect Changes in the Physical Properties of Lactose during the Lubrication Process Required for Drug Formulation.

    PubMed

    Dohi, Masafumi; Momose, Wataru; Yamashita, Kazunari; Hakomori, Tadashi; Sato, Shusaku; Noguchi, Shuji; Terada, Katsuhide

    2017-02-01

    Manufacturing the solid dosage form of an orally administered drug requires lubrication to enhance manufacturability, ensuring that critical quality attributes such as disintegration and dissolution of the drug product are maintained during manufacture. Here, to evaluate lubrication performance during manufacture, we used terahertz attenuated total reflection (THz-ATR) spectroscopy to detect differences in the physical characteristics of the lubricated powder. We applied a simple formulation prepared by blending granulated lactose as filler with magnesium stearate as lubricant. A flat tablet was prepared using the lubricated powder to acquire sharp THz-ATR absorption peaks of the samples. First, we investigated the effects of lubricant concentration and compression pressure on preparation of the tablet and then determined the effect of the pressure applied to samples in contact with the ATR prism on sample absorption amplitude. We focused on the differences in the magnitudes of spectra at the lactose-specific frequency. Second, we conducted the dynamic lubrication process using a 120-L mixer to investigate differences in the magnitudes of absorption corresponding to the lactose-specific frequency during lubrication. In both studies, enriching the lubricated powder with a higher concentration of magnesium stearate or prolonging blending time correlated with higher magnitudes of spectra at the lactose-specific frequency. Further, in the dynamic lubrication study, the wettability and disintegration time of the tablets were compared with the absorption spectra amplitudes at the lactose-specific frequency. We conclude that THz-ATR spectroscopy is useful for detecting differences in densities caused by a change in the physical properties of lactose during lubrication.

  18. Wideband Aural Acoustic Absorbance Predicts Conductive Hearing Loss in Children

    PubMed Central

    Keefe, Douglas H.; Sanford, Chris A.; Ellison, John C.; Fitzpatrick, Denis F.; Gorga, Michael P.

    2013-01-01

    Objective This study tested the hypothesis that wideband aural absorbance predicts conductive hearing loss (CHL) in children medically classified as having otitis media with effusion. Design Absorbance was measured in the ear canal over frequencies from 0.25 to 8 kHz at ambient pressure or as a swept tympanogram. CHL was defined using criterion air-bone gaps of 20, 25 and 30 dB at octaves from 0.25 to 4 kHz. A likelihood-ratio predictor of CHL was constructed across frequency for ambient absorbance and across frequency and pressure for absorbance tympanometry. Performance was evaluated at individual frequencies and for any frequency at which a CHL was present. Study Sample Absorbance and conventional 226-Hz tympanograms were measured in children of age 3 to 8 years with CHL and with normal hearing. Results Absorbance was smaller at frequencies above 0.7 kHz in the CHL group than the control group. Based on the area under the receiver operating characteristic curve, wideband absorbance in ambient and tympanometric tests were significantly better predictors of CHL than tympanometric width, the best 226-Hz predictor. Accuracies of ambient and tympanometric wideband absorbance did not differ. Conclusions Absorbance accurately predicted CHL in children and was more accurate than conventional 226-Hz tympanometry. PMID:23072655

  19. Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

    NASA Technical Reports Server (NTRS)

    Ellis, Tayera

    2015-01-01

    Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

  20. A Mechanism for Frequency Modulation in Songbirds Shared with Humans

    PubMed Central

    Margoliash, Daniel

    2013-01-01

    In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways. PMID:23825417

  1. A mechanism for frequency modulation in songbirds shared with humans.

    PubMed

    Amador, Ana; Margoliash, Daniel

    2013-07-03

    In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways.

  2. High frequency pressure oscillator for microcryocoolers.

    PubMed

    Vanapalli, S; ter Brake, H J M; Jansen, H V; Zhao, Y; Holland, H J; Burger, J F; Elwenspoek, M C

    2008-04-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80 K, delivering a cooling power of 10 mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5 MPa and compression volume of about 22.6 mm(3) when operating the actuator with a peak-to-peak sinusoidal voltage of 100 V at a frequency of 1 kHz. The electrical power input was 2.73 W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.

  3. High frequency pressure oscillator for microcryocoolers

    NASA Astrophysics Data System (ADS)

    Vanapalli, S.; ter Brake, H. J. M.; Jansen, H. V.; Zhao, Y.; Holland, H. J.; Burger, J. F.; Elwenspoek, M. C.

    2008-04-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80K, delivering a cooling power of 10mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5MPa and compression volume of about 22.6mm3 when operating the actuator with a peak-to-peak sinusoidal voltage of 100V at a frequency of 1kHz. The electrical power input was 2.73W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.

  4. Internal friction and velocity measurements. [vacuum effects on lunar basalt resonance

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Ahlberg, L.; Curnow, J.

    1976-01-01

    The Q of a lunar basalt sample was measured under varying vacuum conditions, and it was found that even at pressures as low as 10 to the -7th to 10 to the -10th torr, substantial increases in Q with decreasing pressure are observed, while the resonant frequency increases only slightly. This suggests that only small amounts of volatiles are sufficient to increase the internal friction (lower the Q) dramatically. The technique of vibrating encapsulated samples in the torsional mode was used to measure Q of terrestrial rocks as a function of hydrostatic pressure under lunar vacuum conditions. Young's modulus measurements in the temperature range 25-600 C under a variety of conditions including high vacuum show no evidence of any irreversibility upon temperature cycling and no indication that the high Q-values obtained are associated with any permanent structure changes such as the formation of lossless 'welded' contacts.

  5. Attenuation of the Acoustic Signal Propagating Through a Bubbly Liquid Layer

    NASA Astrophysics Data System (ADS)

    Gubaidullin, D. A.; Nikiforov, A. A.

    2018-01-01

    The acoustic signal dynamics in a five-layer medium containing two liquid layers with polydisperse gas bubbles has been investigated. Calculations have been made for the interaction between the pulse perturbation of smallamplitude pressure and a multilayer sample containing two layers of industrial gel with polydisperse air bubbles. It has been shown that a small content of bubbles (about 0.1 vol. %) in a thin gel layer decreases tenfold or more the amplitude of acoustic waves with frequencies close to the resonance frequency of natural oscillations of bubbles. There are frequency ranges thereby where the influence of the bubbly layer is insignificant.

  6. Models of brachial to finger pulse wave distortion and pressure decrement.

    PubMed

    Gizdulich, P; Prentza, A; Wesseling, K H

    1997-03-01

    To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.

  7. High-pressure behavior of amorphous selenium from ultrasonic measurements and Raman spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Z.; Liu, X. R.; Hong, S. M., E-mail: hpswjtu@gmail.com, E-mail: smhong@home.swjtu.edu.cn

    2014-07-07

    The high-pressure behavior of melt-quenched amorphous selenium (a-Se) has been investigated via ultrasonic measurements and Raman scattering at room temperature. The ultrasonic measurements were conducted on a-Se in a multi-anvil apparatus with two different sample assemblies at pressures of up to 4.5 and 4.8 GPa. We discovered that similar kinks occur in the slopes of the pressure dependence characteristics of the travel time and the sound velocity in both shear and longitudinal waves in the 2.0–2.5 GPa range. These kinks are independent of the sample assemblies, indicating an intrinsic transformation of the a-Se. Additionally, we deduced the pressure-volume relationship of a-Se frommore » the sound velocity characteristics using the Birch–Murnaghan equation of state, and the results agreed well with those of previous reports. In situ high-pressure Raman scattering measurements of a-Se were conducted in a diamond anvil cell with an 830 nm excitation line up to a pressure of 4.3 GPa. We found that the characteristic band of a-Se at ∼250 cm{sup −1} experienced a smooth shift to a lower frequency with pressure, but a sharp slope change in the band intensity versus pressure occurred near 2.5 GPa. The results of X-ray diffraction and differential scanning calorimetry measurements indicate that the samples remain in their amorphous states after decompression. Thus, we proposed that the abnormal compression behavior of a-Se in the 2.0–2.5 GPa range can be attributed to pressure-induced local atomic reconfiguration, implying an amorphous-amorphous transition of the elementary selenium.« less

  8. Thermal conductivity of nanocrystalline silicon: importance of grain size and frequency-dependent mean free paths.

    PubMed

    Wang, Zhaojie; Alaniz, Joseph E; Jang, Wanyoung; Garay, Javier E; Dames, Chris

    2011-06-08

    The thermal conductivity reduction due to grain boundary scattering is widely interpreted using a scattering length assumed equal to the grain size and independent of the phonon frequency (gray). To assess these assumptions and decouple the contributions of porosity and grain size, five samples of undoped nanocrystalline silicon have been measured with average grain sizes ranging from 550 to 64 nm and porosities from 17% to less than 1%, at temperatures from 310 to 16 K. The samples were prepared using current activated, pressure assisted densification (CAPAD). At low temperature the thermal conductivities of all samples show a T(2) dependence which cannot be explained by any traditional gray model. The measurements are explained over the entire temperature range by a new frequency-dependent model in which the mean free path for grain boundary scattering is inversely proportional to the phonon frequency, which is shown to be consistent with asymptotic analysis of atomistic simulations from the literature. In all cases the recommended boundary scattering length is smaller than the average grain size. These results should prove useful for the integration of nanocrystalline materials in devices such as advanced thermoelectrics.

  9. Influence of gas law on ultrasonic behaviour of porous media under pressure.

    PubMed

    Griffiths, S; Ayrault, C

    2010-06-01

    This paper deals with the influence of gas law on ultrasonic behaviour of porous media when the saturating fluid is high pressured. Previous works have demonstrated that ultrasonic transmission through a porous sample with variations of the static pressure (up to 18 bars) of the saturating fluid allows the characterization of high damping materials. In these studies, the perfect gas law was used to link static pressure and density, which is disputable for high pressures. This paper compares the effects of real and perfect gas laws on modeled transmission coefficient for porous foams at these pressures. Direct simulations and a mechanical parameters estimation from minimization show that results are very similar in both cases. The real gas law is thus not necessary to describe the acoustic behaviour of porous media at low ultrasonic frequencies (100 kHz) up to 20 bars. 2010 Elsevier B.V. All rights reserved.

  10. Characterization of Low-Frequency Combustion Stability of the Fastrac Engine

    NASA Technical Reports Server (NTRS)

    Rocker, Marvin; Jones, Preston (Technical Monitor)

    2002-01-01

    A series of tests were conducted to measure the combustion performance of the Fastrac engine thrust chamber. During mainstage, the thrust chamber exhibited no large-amplitude chamber pressure oscillations that could be identified as low-frequency combustion instability or 'chug'. However, during start-up and shutdown, the thrust chamber very briefly exhibited large-amplitude chamber pressure oscillations that were identified as chug. These instabilities during start-up and shutdown were regarded as benign due to their brevity. Linear models of the thrust chamber and the propellant feed systems were formulated for both the thrust chamber component tests and the flight engine tests. These linear models determined the frequency and decay rate of chamber pressure oscillations given the design and operating conditions of the thrust chamber and feed system. The frequency of chamber pressure oscillations determined from the model closely matched the frequency of low-amplitude, low-frequency chamber pressure oscillations exhibited in some of the later thrust chamber mainstage tests. The decay rate of the chamber pressure oscillations determined from the models indicated that these low-frequency oscillations were stable. Likewise, the decay rate, determined from the model of the flight engine tests indicated that the low-frequency chamber pressure oscillations would be stable.

  11. Correlation between structural change and electrical transport properties of Fe-doped chrysotile nanotubes under high pressure

    NASA Astrophysics Data System (ADS)

    Zhang, Junkai; Yang, Lili; Wu, Xiaoxin; Wei, Maobin; Liu, Yanqing; Gao, Chunxiao; Yang, Jinghai; Ma, Yanzhang

    2018-04-01

    Fe3+ doped chrysotile nanotubes (NTs) have been synthesized under controlled hydrothermal conditions, and have been characteristic of layered-walls and room-temperature ferromagnetism. High-pressure in situ impedance spectra and synchrotron XRD measurements are performed on Fe-doped chrysotile NTs to reveal the electrical transport and structural properties under compression. Sample resistance (R sum) was found to increase with the pressure elevation, accompanying the step decrease in the grain boundary relaxation frequency (f gb), which reflects the bandgap broadening and dipoles polarization weakening due to the application of pressure. Furthermore, it is found that both R sum and f gb change their pressure dependences at ~5.0 GPa, which is attributed to the nonlinear compressibility of c-axis and even the underlying lattice distortion of monoclinic structure obtained in the XRD observations.

  12. Deposition of diamond-like films by ECR microwave plasma

    NASA Technical Reports Server (NTRS)

    Shing, Yuh-Han (Inventor); Pool, Frederick S. (Inventor)

    1995-01-01

    Hard amorphous hydrogenated carbon, diamond-like films are deposited using an electron cyclotron resonance microwave plasma with a separate radio frequency power bias applied to a substrate stage. The electron cyclotron resonance microwave plasma yields low deposition pressure and creates ion species otherwise unavailable. A magnetic mirror configuration extracts special ion species from a plasma chamber. Different levels of the radio frequency power bias accelerate the ion species of the ECR plasma impinging on a substrate to form different diamond-like films. During the deposition process, a sample stage is maintained at an ambient temperature of less than 100.degree. C. No external heating is applied to the sample stage. The deposition process enables diamond-like films to be deposited on heat-sensitive substrates.

  13. IMPACT OF VENTILATION FREQUENCY AND PARENCHYMAL STIFFNESS ON FLOW AND PRESSURE DISTRIBUTION IN A CANINE LUNG MODEL

    PubMed Central

    Amini, Reza; Kaczka, David W.

    2013-01-01

    To determine the impact of ventilation frequency, lung volume, and parenchymal stiffness on ventilation distribution, we developed an anatomically-based computational model of the canine lung. Each lobe of the model consists of an asymmetric branching airway network subtended by terminal, viscoelastic acinar units. The model allows for empiric dependencies of airway segment dimensions and parenchymal stiffness on transpulmonary pressure. We simulated the effects of lung volume and parenchymal recoil on global lung impedance and ventilation distribution from 0.1 to 100 Hz, with mean transpulmonary pressures from 5 to 25 cmH2O. With increasing lung volume, the distribution of acinar flows narrowed and became more synchronous for frequencies below resonance. At higher frequencies, large variations in acinar flow were observed. Maximum acinar flow occurred at first antiresonance frequency, where lung impedance achieved a local maximum. The distribution of acinar pressures became very heterogeneous and amplified relative to tracheal pressure at the resonant frequency. These data demonstrate the important interaction between frequency and lung tissue stiffness on the distribution of acinar flows and pressures. These simulations provide useful information for the optimization of frequency, lung volume, and mean airway pressure during conventional ventilation or high frequency oscillation (HFOV). Moreover our model indicates that an optimal HFOV bandwidth exists between the resonant and antiresonant frequencies, for which interregional gas mixing is maximized. PMID:23872936

  14. Social support and health among elderly Kuwaitis.

    PubMed

    Al-Kandari, Yagoub Y; Crews, Douglas E

    2014-07-01

    The aim of this study was to examine differences in several aspects of health between Kuwaiti men and women aged 60 years and over across three age categories (60-69, 70-79, 80+ years). The relationships between several social support variables, somatic symptoms and systolic and diastolic blood pressures were examined. A total of 1427 adult men (472) and women (955) aged 60 years and over representing all six governorates were selected. Data were collected during 2008-2009 by interview and completion of a questionnaire by participants in their own homes, after obtaining their informed consent. The Social Support Scale (SSS), Frequency of Contact Scale (FOC), Strength of Relations (SOR), Somatic Symptoms Inventory (SSI) and self-rated scales of general health were included. Systolic and diastolic blood pressures were measured. The data show that self-rated health and health in the last year differ significantly across age groups. Glycaemia differed significantly across the three age groups for the total sample. Systolic and diastolic blood pressure were higher in older respondents than younger ones, but no significant differences were observed between men and women. No significant differences in somatic symptoms were observed across the three age groups. Strength of relationship, frequency of contact, social support and children living with an elderly adult were all associated with fewer somatic symptoms, and all, except social support, were associated with lower systolic and diastolic blood pressure. Having children, the perception of social support, frequency of contact with, and strength of, relationships with kin are important modulators of somatic symptoms and blood pressure among elderly Kuwaitis.

  15. Geophysical Signatures to Monitor Fluids and Mineralization for CO2 Sequestration in Basalts

    NASA Astrophysics Data System (ADS)

    Otheim, L. T.; Adam, L.; Van Wijk, K.; Batzle, M. L.; Mcling, T. L.; Podgorney, R. K.

    2011-12-01

    Carbon dioxide sequestration in large reservoirs can reduce emissions of this green house gas into the atmosphere. Basalts are promising host rocks due to their volumetric extend, worldwide distribution, and recent observations that CO2-water mixtures react with basalt minerals to precipitate as carbonate minerals, trapping the CO2. The chemical reaction between carbonic acid and minerals rich in calcium, magnesium and iron precipitates carbonates in the pore space. This process would increase the elastic modulus and velocity of the rock. At the same time, the higher compressibility of CO2 over water changes the elastic properties of the rock, decreasing the saturated rock bulk modulus and the P-wave velocity. Reservoirs where the rock properties change as a result of fluid or pressure changes are commonly monitored with seismic methods. Here we present experiments to study the feasibility of monitoring CO2 migration in a reservoir and CO2-rock reactions for a sequestration scenario in basalts. Our goal is to measure the rock's elastic response to mineralization with non-contacting ultrasonic lasers, and the effect of fluid substitution at reservoir conditions at seismic and ultrasonic frequencies. For the fluid substitution experiment we observe changes in the P- and S-wave velocities when saturating the sample with super-critical (sc) CO2, CO2-water mixtures and water alone for different pore and confining pressures. The bulk modulus of the rock is significantly dependent on frequency in the 2~to 106~Hz range, for CO2-water mixtures and pure water saturations. Dry and pure CO2 (sc or gas) do not show a frequency dependence on the modulus. Moreover, the shear wave modulus is not dispersive for either fluid. The frequency dependence of the elastic parameters is related to the attenuation (1/Q) of the rock. We will show the correlation between frequency dependent moduli and attenuation data for the different elastic moduli of the rocks. Three other basalt samples were stored in a pressure chamber with a sc CO2-water solution to study the effect of mineralization on the elastic properties of the rock. The rock elastic properties are recorded with non-contacting ultrasonic lasers at room conditions. After 15 weeks the first post-mineralization scan showed differences in the rock velocities with respect to the pre-mineralization scan. The analysis is done through coda wave interferometry and direct arrivals. The samples were inserted back into the pressure vessel for continuing mineralization and subsequent scans. Finally, we will discuss the applicability of Gassmann's equation and how the combination of mineralization together with CO2-water mixture affects the velocity of waves in basalt rocks.

  16. Combined Raman and infrared investigation of the insulator-to-metal transition in NiS2-xSex compounds

    NASA Astrophysics Data System (ADS)

    Marini, C.; Perucchi, A.; Chermisi, D.; Dore, P.; Valentini, M.; Topwal, D.; Sarma, D. D.; Lupi, S.; Postorino, P.

    2011-12-01

    Ambient-condition Raman spectra were collected in the strongly correlated NiS1-xSex pyrite (0≤x≤1.2). Two samples (x=0 and x=0.55) were studied as a function of pressure up to 10 GPa, and for the x=0.55 sample the pressure dependence of the infrared reflectivity was also measured (0-10 GPa). This gave a complete picture of the optical response of that system on approaching the metallic state both by application of pres-sure and/or by Se alloying, which corresponds to a volume expansion. A peculiar nonmonotonic (V-shaped) volume dependence was found for the quasiparticle spectral weight of both pure and Se-doped compounds. In the x=0.55 sample the vibrational frequencies of the chalcogen dimer show an anomalous volume dependence on entering the metallic phase. The abrupt softening observed, particularly significant for the Se-Se pair, indicates the relevant role of the softness of the Se-Se bond as previously suggested by theoretical calculations.

  17. Combustion Instability in an Acid-Heptane Rocket with a Pressurized-Gas Propellant Pumping System

    NASA Technical Reports Server (NTRS)

    Tischler, Adelbert O.; Bellman, Donald R.

    1951-01-01

    Results of experimental measurements of low-frequency combustion instability of a 300-pound thrust acid-heptane rocket engine were compared to the trends predicted by an analysis of combustion instability in a rocket engine with a pressurized-gas propellant pumping system. The simplified analysis, which assumes a monopropellant model, was based on the concept of a combustion the delay occurring from the moment of propellant injection to the moment of propellant combustion. This combustion time delay was experimentally measured; the experimental values were of approximately half the magnitude predicted by the analysis. The pressure-fluctuation frequency for a rocket engine with a characteristic length of 100 inches and operated at a combustion-chamber pressure of 280 pounds per square inch absolute was 38 cycles per second; the analysis indicated. a frequency of 37 cycles per second. Increasing combustion-chamber characteristic length decreased the pressure-fluctuation frequency, in conformity to the analysis. Increasing the chamber operating pressure or increasing the injector pressure drop increased the frequency. These latter two effects are contrary to the analysis; the discrepancies are attributed to the conflict between the assumptions made to simplify the analysis and the experimental conditions. Oxidant-fuel ratio had no apparent effect on the experimentally measured pressure-fluctuation frequency for acid-heptane ratios from 3.0 to 7.0. The frequencies decreased with increased amplitude of the combustion-chamber pressure variations. The analysis indicated that if the combustion time delay were sufficiently short, low-frequency combustion instability would be eliminated.

  18. Seafloor Pressure Array Studies at Ultra-Low Frequencies

    DTIC Science & Technology

    1991-01-01

    broadband instrument design and deployment. In order to measure broadband noise routinely, a low frequency pressure gauge designed for deep ocean...below the microseism band (Moore et al, 1981). A differential pressure gauge , developed for low frequency recordings by Cox et al (1984) and sensitive to...design differential pressure gauge (Cox et al, 1984) with a sensitivity -3- ULF Seafloor Pressure Array Studies range of 0.01-5 Hz. The high

  19. Noise and complexity in human postural control: interpreting the different estimations of entropy.

    PubMed

    Rhea, Christopher K; Silver, Tobin A; Hong, S Lee; Ryu, Joong Hyun; Studenka, Breanna E; Hughes, Charmayne M L; Haddad, Jeffrey M

    2011-03-17

    Over the last two decades, various measures of entropy have been used to examine the complexity of human postural control. In general, entropy measures provide information regarding the health, stability and adaptability of the postural system that is not captured when using more traditional analytical techniques. The purpose of this study was to examine how noise, sampling frequency and time series length influence various measures of entropy when applied to human center of pressure (CoP) data, as well as in synthetic signals with known properties. Such a comparison is necessary to interpret data between and within studies that use different entropy measures, equipment, sampling frequencies or data collection durations. The complexity of synthetic signals with known properties and standing CoP data was calculated using Approximate Entropy (ApEn), Sample Entropy (SampEn) and Recurrence Quantification Analysis Entropy (RQAEn). All signals were examined at varying sampling frequencies and with varying amounts of added noise. Additionally, an increment time series of the original CoP data was examined to remove long-range correlations. Of the three measures examined, ApEn was the least robust to sampling frequency and noise manipulations. Additionally, increased noise led to an increase in SampEn, but a decrease in RQAEn. Thus, noise can yield inconsistent results between the various entropy measures. Finally, the differences between the entropy measures were minimized in the increment CoP data, suggesting that long-range correlations should be removed from CoP data prior to calculating entropy. The various algorithms typically used to quantify the complexity (entropy) of CoP may yield very different results, particularly when sampling frequency and noise are different. The results of this study are discussed within the context of the neural noise and loss of complexity hypotheses.

  20. Gender differences in body-sway factors of center of foot pressure in a static upright posture and under the influence of alcohol intake.

    PubMed

    Kitabayashi, Tamotsu; Demura, Shinichi; Noda, Masahiro; Yamada, Takayoshi

    2004-07-01

    This study aimed to examine gender differences in 4 body-sway factors of the center of foot pressure (CFP) during a static upright posture and the influence of alcohol intake on them. Four body-sway factors were interpreted in previous studies using factor analysis (the principal factor method and oblique solution by promax-rotation) on 220 healthy young males and females as follows; unit time sway, front-back sway, left-right sway and high frequency band power. The CFP measurement for 1 min was carried out twice with 1 min rest. The measurements of blood pressure, heart rate, whole body reaction time, standing on one leg with eyes closed, and CFP were carried out before and after the alcohol intake using 11 healthy young males and females. The measurement device used was an Anima's stabilometer G5500. The data sampling frequency was 20 Hz. Reliability of 4 body-sway factors was very high. Significant gender differences were found in the left-right sway and the high frequency band power factors, but the influence on body-sway is, as a whole, can be disregarded. These four sway factors can determine the influence of alcohol intake as efficient as 32 sway parameters.

  1. Characterization of compressed earth blocks using low frequency guided acoustic waves.

    PubMed

    Ben Mansour, Mohamed; Ogam, Erick; Fellah, Z E A; Soukaina Cherif, Amel; Jelidi, Ahmed; Ben Jabrallah, Sadok

    2016-05-01

    The objective of this work was to analyze the influence of compaction pressure on the intrinsic acoustic parameters (porosity, tortuosity, air-flow resistivity, viscous, and thermal characteristic lengths) of compressed earth blocks through their identification by solving an inverse acoustic wave transmission problem. A low frequency acoustic pipe (60-6000 Hz of length 22 m, internal diameter 3.4 cm) was used for the experimental characterization of the samples. The parameters were identified by the minimization of the difference between the transmissions coefficients data obtained in the pipe with that from an analytical interaction model in which the compressed earth blocks were considered as having rigid frames. The viscous and thermal effects in the pores were accounted for by employing the Johnson-Champoux-Allard-Lafarge model. The results obtained by inversion for high-density compressed earth blocks showed some discordance between the model and experiment especially for the high frequency limit of the acoustic characteristics studied. This was as a consequence of applying high compaction pressure rendering them very highly resistive therefore degrading the signal-to-noise ratios of the transmitted waves. The results showed that the airflow resistivity was very sensitive to the degree of the applied compaction pressure used to form the blocks.

  2. Flight evaluation of a pneumatic system for unsteady pressure measurements using conventional sensors

    NASA Technical Reports Server (NTRS)

    Curry, Robert E.; Gilyard, Glenn B.

    1989-01-01

    A flight experiment was conducted to evaluate a pressure measurement system which uses pneumatic tubing and remotely located electronically scanned pressure transducer modules for in-flight unsteady aerodynamic studies. A parametric study of tubing length and diameter on the attenuation and lag of the measured signals was conducted. The hardware was found to operate satisfactorily at rates of up to 500 samples/sec per port in flight. The signal attenuation and lag due to tubing were shown to increase with tubing length, decrease with tubing diameter, and increase with altitude over the ranges tested. Measurable signal levels were obtained for even the longest tubing length tested, 4 ft, at frequencies up to 100 Hz. This instrumentation system approach provides a practical means of conducting detailed unsteady pressure surveys in flight.

  3. A method to determine the acoustic reflection and absorption coefficients of porous media by using modal dispersion in a waveguide.

    PubMed

    Prisutova, Jevgenija; Horoshenkov, Kirill; Groby, Jean-Philippe; Brouard, Bruno

    2014-12-01

    The measurement of acoustic material characteristics using a standard impedance tube method is generally limited to the plane wave regime below the tube cut-on frequency. This implies that the size of the tube and, consequently, the size of the material specimen must remain smaller than a half of the wavelength. This paper presents a method that enables the extension of the frequency range beyond the plane wave regime by at least a factor of 3, so that the size of the material specimen can be much larger than the wavelength. The proposed method is based on measuring of the sound pressure at different axial locations and applying the spatial Fourier transform. A normal mode decomposition approach is used together with an optimization algorithm to minimize the discrepancy between the measured and predicted sound pressure spectra. This allows the frequency and angle dependent reflection and absorption coefficients of the material specimen to be calculated in an extended frequency range. The method has been tested successfully on samples of melamine foam and wood fiber. The measured data are in close agreement with the predictions by the equivalent fluid model for the acoustical properties of porous media.

  4. Impaired pulsation absorber mechanism in idiopathic normal pressure hydrocephalus: laboratory investigation.

    PubMed

    Park, Eun-Hyoung; Eide, Per Kristian; Zurakowski, David; Madsen, Joseph R

    2012-12-01

    The pathophysiology of normal pressure hydrocephalus (NPH), and the related problem of patient selection for treatment of this condition, have been of great interest since the description of this seemingly paradoxical condition nearly 50 years ago. Recently, Eide has reported that measurements of the amplitude of the intracranial pressure (ICP) can both positively and negatively predict response to CSF shunting. Specifically, the fraction of time spent in a "high amplitude" (> 4 mm Hg) state predicted response to shunting, which may represent a marker for hydrocephalic pathophysiology. Increased ICP amplitude might suggest decreased brain compliance, meaning a static measure of a pressure-volume ratio. Recent studies of canine data have shown that the brain compliance can be described as a frequency-dependent function. The normal canine brain seems to show enhanced ability to absorb the pulsations around the heart rate, quantified as a cardiac pulsation absorbance (CPA), with properties like a notch filter in engineering. This frequency dependence of the function is diminished with development of hydrocephalus in dogs. In this pilot study, the authors sought to determine whether frequency dependence could be observed in humans, and whether the frequency dependence would be any different in epochs with high ICP amplitude compared with epochs of low ICP amplitude. Systems analysis was applied to arterial blood pressure (ABP) and ICP waveforms recorded from 10 patients undergoing evaluations of idiopathic NPH to calculate a time-varying transfer function that reveals frequency dependence and CPA, the measure of frequency-dependent compliance previously used in animal experiments. The ICP amplitude was also calculated in the same samples, so that epochs with high (> 4 mm Hg) versus low (≤ 4 mm Hg) amplitude could be compared in CPA and transfer functions. Transfer function analysis for the more "normal" epochs with low amplitude exhibits a dip or notch in the physiological frequency range of the heart rate, confirming in humans the pulsation absorber phenomenon previously observed in canine studies. Under high amplitude, however, the dip in the transfer function is absent. An inverse relationship between CPA index and ICP amplitude is evident and statistically significant. Thus, elevated ICP amplitude indicates decreased performance of the human pulsation absorber. The results suggest that the human intracranial system shows frequency dependence as seen in animal experiments. There is an inverse relationship between CPA index and ICP amplitude, indicating that higher amplitudes may occur with a reduced performance of the pulsation absorber. Our findings show that frequency dependence can be observed in humans and imply that reduced frequency-dependent compliance may be responsible for elevated ICP amplitude observed in patients who respond to CSF shunting.

  5. Frequency-dependent baroreflex control of blood pressure and heart rate during physical exercise.

    PubMed

    Spadacini, Giammario; Passino, Claudio; Leuzzi, Stefano; Valle, Felice; Piepoli, Massimo; Calciati, Alessandro; Sleight, Peter; Bernardi, Luciano

    2006-02-15

    It is widely recognised that during exercise vagal heart rate control is markedly impaired but blood pressure control may or may not be retained. We hypothesised that this uncertainty arose from the differing responses of the vagus (fast) and sympathetic (slow) arms of the autonomic effectors, and to differing sympatho-vagal balance at different exercise intensities. We studied 12 normals at rest, during moderate (50% maximal heart rate) and submaximal (80% maximal heart rate) exercise. The carotid baroreceptors were stimulated by sinusoidal neck suction at the frequency of the spontaneous high- (during moderate exercise) and low-frequency (during submaximal) fluctuations in heart period and blood pressure. The increases in these oscillations induced by neck suction were measured by autoregressive spectral analysis. At rest neck stimulation increased variability at low frequency (RR: from 6.99+/-0.24 to 8.87+/-0.18 ln-ms2; systolic pressure: from 3.05+/-1.7 to 4.09+/-0.17 ln-mm Hg2) and high frequency (RR: from 4.67+/-0.25 to 6.79+/-0.31 ln-ms2; systolic pressure: from 1.93+/-0.2 to 2.67+/-0.125 ln-mm Hg2) (all p<0.001). During submaximal exercise RR variability decreased but systolic pressure variability rose (p<0.01 vs rest); during submaximal exercise low-frequency neck stimulation increased the low-frequency fluctuations in blood pressure (2.35+/-0.51 to 4.25+/-0.38 ln-mm Hg2, p<0.05) and RR. Conversely, neck suction at high frequency was ineffective on systolic pressure, and had only minor effects on RR interval during moderate exercise. During exercise baroreflex control is active on blood pressure, but the efferent response on blood pressure and heart rate is only detected during low frequency stimulation, indicating a frequency-dependent effect.

  6. A Factorial Data Rate and Dwell Time Experiment in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    DeLoach, R.

    2000-01-01

    This report is an introductory tutorial on the application of formal experiment design methods to wind tunnel testing, for the benefit of aeronautical engineers with little formal experiment design training. It also describes the results of a Study to determine whether increases in the sample rate and dwell time of the National Transonic Facility data system Would result in significant changes in force and moment data. Increases in sample rate from 10 samples per second to 50 samples per second were examined, as were changes in dwell time from one second per data point to two seconds. These changes were examined for a representative aircraft model in a range of tunnel operating conditions defined by angles of attack from 0 deg to 3.8 degrees, total pressure from 15.0 psi to 24.1 psi, and Mach numbers from 0.52 to 0.82. No statistically significant effect was associated with the change in sample rate. The change in dwell time from one second to two seconds affected axial force measurements, and to a lesser degree normal force measurements. This dwell effect comprises a "rectification error" caused by incomplete cancellation of the positive and negative elements of certain low frequency dynamic components that are not rejected by the one-Hz low-pass filters of the data system. These low frequency effects may be due to tunnel circuit phenomena and other sources. The magnitude of the dwell effect depends on dynamic pressure, with angle of attack and Mach number influencing the strength of this dependence. An analysis is presented which suggests that the magnitude of the rectification error depends on the ratio of measurement dwell time to the period of the low-frequency dynamics, as well as the amplitude of the dynamics The essential conclusion of this analysis is that extending the dwell time (or, equivalently, replicating short-dwell data points) reduces the rectification error.

  7. Design parameters of stainless steel plates for maximizing high frequency ultrasound wave transmission.

    PubMed

    Michaud, Mark; Leong, Thomas; Swiergon, Piotr; Juliano, Pablo; Knoerzer, Kai

    2015-09-01

    This work validated, in a higher frequency range, the theoretical predictions made by Boyle around 1930, which state that the optimal transmission of sound pressure through a metal plate occurs when the plate thickness equals a multiple of half the wavelength of the sound wave. Several reactor design parameters influencing the transmission of high frequency ultrasonic waves through a stainless steel plate were examined. The transmission properties of steel plates of various thicknesses (1-7 mm) were studied for frequencies ranging from 400 kHz to 2 MHz and at different distances between plates and transducers. It was shown that transmission of sound pressure through a steel plate showed high dependence of the thickness of the plate to the frequency of the sound wave (thickness ratio). Maximum sound pressure transmission of ∼ 60% of the incident pressure was observed when the ratio of the plate thickness to the applied frequency was a multiple of a half wavelength (2 MHz, 6mm stainless steel plate). In contrast, minimal sound pressure transmission (∼ 10-20%) was measured for thickness ratios that were not a multiple of a half wavelength. Furthermore, the attenuation of the sound pressure in the transmission region was also investigated. As expected, it was confirmed that higher frequencies have more pronounced sound pressure attenuation than lower frequencies. The spatial distribution of the sound pressure transmitted through the plate characterized by sonochemiluminescence measurements using luminol emission, supports the validity of the pressure measurements in this study. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Development of an Atmospheric Pressure Ionization Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    1998-01-01

    A commercial atmospheric pressure ionization mass spectrometer (APIMS) was purchased from EXTREL Mass Spectrometry, Inc. (Pittsburgh, PA). Our research objectives were to adapt this instrument and develop techniques for real-time determinations of the concentrations of trace species in the atmosphere. The prototype instrument is capable of making high frequency measurements with no sample preconcentrations. Isotopically labeled standards are used as an internal standard to obtain high precision and to compensate for changes in instrument sensitivity and analyte losses in the sampling manifold as described by Bandy and coworkers. The prototype instrument is capable of being deployed on NASA C130, Electra, P3, and DC8 aircraft. After purchasing and taking delivery by June 1994, we assembled the mass spectrometer, data acquisition, and manifold flow control instrumentation in electronic racks and performed tests.

  9. Atmospheric pressure plasma jet's characterization and surface wettability driven by neon transformer

    NASA Astrophysics Data System (ADS)

    Elfa, R. R.; Nafarizal, N.; Ahmad, M. K.; Sahdan, M. Z.; Soon, C. F.

    2017-03-01

    Atmospheric pressure plasma driven by Neon transformer power supply argon is presented in this paper. Atmospheric pressure plasma system has attracted researcher interest over low pressure plasma as it provides a flexibility process, cost-efficient, portable device and vacuum-free device. Besides, another golden key of this system is the wide promising application in the field of work cover from industrial and engineering to medical. However, there are still numbers of fundamental investigation that are necessary such as device configuration, gas configuration and its effect. Dielectric barrier discharge which is also known as atmospheric pressure plasma discharge is created when there is gas ionization process occur which enhance the movement of atom and electron and provide energetic particles. These energetic particles can provide modification and cleaning property to the sample surface due to the bombardment of the high reactive ion and radicals to the sample surface. In order to develop atmospheric pressure plasma discharge, a high voltage and high frequency power supply is needed. In this work, we used a neon transformer power supply as the power supply. The flow of the Ar is feed into 10 mm cylinder quartz tube with different treatment time in order to investigate the effect of the plasma discharge. The analysis of each treatment time is presented by optical emission spectroscopy (OES) and water contact angle (WCA) measurement. The increase of gas treatment time shows increases intensity of reactive Ar and reduces the angle of water droplets in water contact angle. Treatment time of 20 s microslide glass surface shows that the plasma needle discharges have modified the sample surface from hydrophilic surface to superhydrophilic surface. Thus, this leads to another interesting application in reducing sample surface adhesion to optimize productivity in the industry of paintings, semiconductor and more.

  10. High temperature pressurized high frequency testing rig and test method

    DOEpatents

    De La Cruz, Jose; Lacey, Paul

    2003-04-15

    An apparatus is described which permits the lubricity of fuel compositions at or near temperatures and pressures experienced by compression ignition fuel injector components during operation in a running engine. The apparatus consists of means to apply a measured force between two surfaces and oscillate them at high frequency while wetted with a sample of the fuel composition heated to an operator selected temperature. Provision is made to permit operation at or near the flash point of the fuel compositions. Additionally a method of using the subject apparatus to simulate ASTM Testing Method D6079 is disclosed, said method involving using the disclosed apparatus to contact the faces of prepared workpieces under a measured load, sealing the workface contact point into the disclosed apparatus while immersing said contact point between said workfaces in a lubricating media to be tested, pressurizing and heating the chamber and thereby the fluid and workfaces therewithin, using the disclosed apparatus to impart a differential linear motion between the workpieces at their contact point until a measurable scar is imparted to at least one workpiece workface, and then evaluating the workface scar.

  11. Laboratory simulations of fluid-induced seismicity in shallow volcanic faults

    NASA Astrophysics Data System (ADS)

    Fazio, Marco; Benson, Philip; Vinciguerra, Sergio; Meredith, Philip

    2015-04-01

    Seismicity is a key tool used for monitoring fracturing and faulting in around volcanoes, with a particular emphasis placed on the frequency (Long period or Low Frequency, LF events) thought to be due to fluid movement, as compared to Volcano-Tectonic activity driven by pure fracture. To better understand these fundamental processes this research presents new rock deformation experiments designed to simulate shallow volcano-tectonic pressure/temperature conditions, linking pore fluid flow to the induced seismicity. A particular emphasis is placed on the conditions of pressure and temperature required to stimulate LF activity. Our setup imposes a rapid pore pressure release or "venting" via a small pre-drilled axial conduit to stimulate rapid fluid movement through an established fracture damage zone via a two stage process. Firstly experiments are conducted to generate a through-going shear fracture, with pore fluid connectivity to this fracture enhanced via the axial conduit. The shear failure is imaged via AE location with ~mm scale accuracy. The second stage vents pore fluid pressure via an electrical solenoid valve. We find that this second stage is accompanied by a swarm of LF activity akin to Long Period (LP) activity on active volcanoes. We find that a significant change in the dominant frequency of LF events is recorded as pore fluid pressure decrease through, and beyond, the water boiling point and the transition between LF and VLF occurred at the pressure at which the superheated water turn to vapour. In addition, we observe a significant dependence of the recorded LF upon the fluid flow rate. Finally, we present new data using low frequency (200 kHz) AE sensors, in conjunction with our standard 1 MHz-central-frequency sensors, which permit us to better constraint LF and VLF events with lower attenuation, and hence an improved characterization of these LF seismic signals. Data are used to forecast the final time of failure via the fracture forecast methods of Kilburn (2004), showing a good correlation between measured sample failure time and the forecast time based on AE event rate. Our data showed little change in forecast accuracy when using LF data compared to regular HF data, illustrating the importance of newly fracturing surfaces in the application of such models.

  12. Laboratory simulations of fluid-induced seismicity in shallow volcanic faults

    NASA Astrophysics Data System (ADS)

    Fazio, M.; Benson, P. M.; Vinciguerra, S.

    2014-12-01

    Seismicity is a key tool used for monitoring fracturing and faulting in around volcanoes, with a particular emphasis placed on the frequency (Long period or Low Frequency, LF events) thought to be due to fluid movement, as compared to Volcano-Tectonic activity driven by pure fracture. To better understand these fundamental processes this research presents new rock deformation experiments designed to simulate shallow volcano-tectonic pressure/temperature conditions, linking pore fluid flow to the induced seismicity. A particular emphasis is placed on the conditions of pressure and temperature required to stimulate LF activity. Our setup imposes a rapid pore pressure release or "venting" via a small pre-drilled axial conduit to stimulate rapid fluid movement through an established fracture damage zone via a two stage process. Firstly experiments are conducted to generate a through-going shear fracture, with pore fluid connectivity to this fracture enhanced via the axial conduit. The shear failure is imaged via AE location with ~mm scale accuracy. The second stage vents pore fluid pressure via an electrical solenoid valve. We find that this second stage is accompanied by a swarm of LF activity akin to Long Period (LP) activity on active volcanoes. We find that a significant change in the dominant frequency of LF events is recorded as pore fluid pressure decrease through, and beyond, the water boiling point and the transition between LF and VLF occurred at the pressure at which the superheated water turn to vapour. In addition, we observe a significant dependence of the recorded LF upon the fluid flow rate. Finally, we present new data using low frequency (200 kHz) AE sensors, in conjunction with our standard 1 MHz-central-frequency sensors, which permit us to better constraint LF and VLF events with lower attenuation, and hence an improved characterization of these LF seismic signals. Data are used to forecast the final time of failure via the fracture forecast methods of Kilburn (2004), showing a good correlation between measured sample failure time and the forecast time based on AE event rate. Our data showed little change in forecast accuracy when using LF data compared to regular HF data, illustrating the importance of newly fracturing surfaces in the application of such models.

  13. Quantification of in situ pore pressure and stress in regions of low frequency earthquakes and anomalously low seismic velocity at the Nankai Trough

    NASA Astrophysics Data System (ADS)

    Kitajima, H.; Saffer, D. M.

    2012-12-01

    Recent seismic reflection and ocean bottom seismometer (OBS) studies reveal broad regions of low seismic velocity along the megathrust plate boundary of the Nankai subduction zone offshore SW Japan. These low velocity zones (LVZ's) extend to ~55 km from the trench, corresponding to depths of >~10 km below sea floor. Elevated pore pressure has been invoked as one potential cause of both the LVZ's and very low frequency earthquakes (VLFE) in the outer forearc. Here, we estimate the in-situ pore fluid pressure and stress state within these LVZ's by combining P-wave velocities (Vp) obtained from seismic reflection and OBS data with well-constrained empirical relations between (1) P-wave velocity and porosity; and (2) porosity and effective mean and differential stresses, defined by triaxial deformation tests on drill core samples of the incoming oceanic sediment. We used cores of Lower Shikoku Basin (LSB) hemipelagic mudstone (322-C0011B-19R-5, initial porosity of 43%), and Middle Shikoku Basin (MSB) tuffaceous sandstone (333-C0011D-51X-2, initial porosity of 46%) that have been recovered from IODP Nankai Trough Seismogenic Zone Experiment (NanTroSEIZE) Site C0011 (~20 km seaward from the deformation front). Samples were loaded under a range of different stress paths including isotropic loading, triaxial compression, and triaxial extension. During the tests, all pressures, axial displacement, and pore volume change were continuously monitored; and ultrasonic velocity and permeability were measured at regular intervals. The relationship between Vp and porosity for LSB mudstone is independent of stress path, and is well fit by an empirical function derived by Hoffman and Tobin [2004] for LSB sediments sampled by drilling along Muroto transect, located ~150 km southwest of the NanTroSEIZE study area. The MSB sandstone exhibits slightly higher P-wave velocity than LSB mudstone at a given porosity. Based on our experimental results, and assuming that the sediments in the LVZ's are at shear failure defined by a critical state stress condition, we estimate that effective vertical stress in the LVZ ranges from 15 MPa at 13 km landward of the trench, to 41 MPa at a distance of 55 km. The maximum horizontal effective stress ranges from 41-124 MPa over this region. Excess pore fluid pressure ranges from 15-81 MPa, corresponding to modified pore pressure ratios, λ* of 0.44-0.73. If LVZ is composed dominantly of sandstones, both the effective vertical and horizontal stresses would be lower, and the excess pore pressure would be higher, with pore pressure ratios λ* = 0.31-0.90. Our results suggest that the sediments have been loaded under poorly drained conditions, and that pore fluids support ≥~53-91 % of the overburden stress along the base of the accretionary wedge across the outer forearc. The low effective stress should lead to a mechanically weak plate boundary, and is spatially correlated with well-located low-frequency earthquakes in the outer accretionary wedge. The heterogeneous distribution of inferred pore pressure also suggests that fluid sources and drainage are localized and possibly transient.

  14. Semiconductor nanomembrane-based sensors for high frequency pressure measurements

    NASA Astrophysics Data System (ADS)

    Ruan, Hang; Kang, Yuhong; Homer, Michelle; Claus, Richard O.; Mayo, David; Sibold, Ridge; Jones, Tyler; Ng, Wing

    2017-04-01

    This paper demonstrates improvements on semiconductor nanomembrane based high frequency pressure sensors that utilize silicon on insulator techniques in combination with nanocomposite materials. The low-modulus, conformal nanomembrane sensor skins with integrated interconnect elements and electronic devices could be applied to vehicles or wind tunnel models for full spectrum pressure analysis. Experimental data demonstrates that: 1) silicon nanomembrane may be used as single pressure sensor transducers and elements in sensor arrays, 2) the arrays may be instrumented to map pressure over the surfaces of test articles over a range of Reynolds numbers, temperature and other environmental conditions, 3) in the high frequency range, the sensor is comparable to the commercial high frequency sensor, and 4) in the low frequency range, the sensor is much better than the commercial sensor. This supports the claim that nanomembrane pressure sensors may be used for wide bandwidth flow analysis.

  15. Sound pressure level gain in an acoustic metamaterial cavity.

    PubMed

    Song, Kyungjun; Kim, Kiwon; Hur, Shin; Kwak, Jun-Hyuk; Park, Jihyun; Yoon, Jong Rak; Kim, Jedo

    2014-12-11

    The inherent attenuation of a homogeneous viscous medium limits radiation propagation, thereby restricting the use of many high-frequency acoustic devices to only short-range applications. Here, we design and experimentally demonstrate an acoustic metamaterial localization cavity which is used for sound pressure level (SPL) gain using double coiled up space like structures thereby increasing the range of detection. This unique behavior occurs within a subwavelength cavity that is 1/10(th) of the wavelength of the incident acoustic wave, which provides up to a 13 dB SPL gain. We show that the amplification results from the Fabry-Perot resonance of the cavity, which has a simultaneously high effective refractive index and effective impedance. We also experimentally verify the SPL amplification in an underwater environment at higher frequencies using a sample with an identical unit cell size. The versatile scalability of the design shows promising applications in many areas, especially in acoustic imaging and underwater communication.

  16. An Observation of Repeating Events at local asperities during a Laboratory Stick-slip Experiment of a Saw-cut Cylindrical Lucite Sample

    NASA Astrophysics Data System (ADS)

    Gu, C.; Mighani, S.; Prieto, G. A.; Mok, U.; Evans, J. B.; Hager, B. H.; Toksoz, M. N.

    2017-12-01

    Repeating earthquakes have been found in subduction zones and interpreted as repeated ruptures of small local asperities. Repeating earthquakes have also been found in oil/gas fields, interpreted as the reactivation of pre-existing faults due to fluid injection/extraction. To mimic the fault rupture of a fault with local asperities, we designed a "stick-slip" experiment using a saw-cut cylindrical Lucite sample, which had sharp localized ridges parallel to the strike of the fault plane. The sample was subjected to conventional triaxial loading with a constant confining pressure of 10 MPa. The axial load was then increased to 6 MPa at a constant rate of 0.12 MPa/sec until the sliding occurred along the fault plane. Ultrasonic acoustic emissions (AEs) were monitored with eight PZT sensors. Two cycles of AEs were detected with the occurrence rate that decreased from the beginning to the end of each cycle, while the relative magnitudes increased. Correlation analysis indicated that these AEs were clustered into two groups - those with frequency content between 200-300kHz and a second group with frequency content between 10-50kHz. The locations of the high-frequency events, with almost identical waveforms, show that these events are from the sharp localized ridges on the saw-cut plane. The locations of the low-frequency events show an approaching process to the high-frequency events for each cycle. In this single experiment, there was a correlation of the proximity of the low-frequency events with the subsequent triggering of large high-frequency repeating events.

  17. High-field/high-pressure ESR

    NASA Astrophysics Data System (ADS)

    Sakurai, T.; Okubo, S.; Ohta, H.

    2017-07-01

    We present a historical review of high-pressure ESR systems with emphasis on our recent development of a high-pressure, high-field, multi-frequency ESR system. Until 2000, the X-band system was almost established using a resonator filled with dielectric materials or a combination of the anvil cell and dielectric resonators. Recent developments have shifted from that in the low-frequency region, such as X-band, to that in multi-frequency region. High-pressure, high-field, multi-frequency ESR systems are classified into two types. First are the systems that use a vector network analyzer or a quasi-optical bridge, which have high sensitivity but a limited frequency region; the second are like our system, which has a very broad frequency region covering the THz region, but lower sensitivity. We will demonstrate the usefulness of our high-pressure ESR system, in addition to its experimental limitations. We also discuss the recent progress of our system and future plans.

  18. Audible thunder characteristic and the relation between peak frequency and lightning parameters

    NASA Astrophysics Data System (ADS)

    Yuhua, Ouyang; Ping, Yuan

    2012-02-01

    In recent summers, some natural lightning optical spectra and audible thunder signals were observed. Twelve events on 15 August 2008 are selected as samples since some synchronizing information about them are obtained, such as lightning optical spectra, surface E-field changes, etc. By using digital filter and Fourier transform, thunder frequency spectra in observation location have been calculated. Then the two main propagation effects, finite amplitude propagation and attenuation by air, are calculated. Upon that we take the test thunder frequency spectra and work backward to recalculate the original frequency spectra near generation location. Thunder frequency spectra and the frequency distribution varying with distance are researched. According to the theories on plasma, the channel temperature and electron density are further calculated by transition parameters of lines in lightning optical spectra. Pressure and the average ionization degree of each discharge channel are obtained by using Saha equations, charge conservation equations and particle conservation equations. Moreover, the relationship between the peak frequency of each thunder and channel parameters of the lightning is studied.

  19. Spontaneous fluctuations in cerebral blood flow: insights from extended-duration recordings in humans

    NASA Technical Reports Server (NTRS)

    Zhang, R.; Zuckerman, J. H.; Levine, B. D.; Blomqvist, C. G. (Principal Investigator)

    2000-01-01

    To determine the dependence of cerebral blood flow (CBF) on arterial pressure over prolonged time periods, we measured beat-to-beat changes in mean CBF velocity in the middle cerebral artery (transcranial Doppler) and mean arterial pressure (Finapres) continuously for 2 h in six healthy subjects (5 men and 1 woman, 18-40 yr old) during supine rest. Fluctuations in velocity and pressure were quantified by the range [(peak - trough)/mean] and coefficients of variation (SD/mean) in the time domain and by spectral analysis in the frequency domain. Mean velocity and pressure over the 2-h recordings were 60 +/- 7 cm/s and 83 +/- 8 mmHg, associated with ranges of 77 +/- 8 and 89 +/- 10% and coefficients of variation of 9.3 +/- 2.2 and 7.9 +/- 2.3%, respectively. Spectral power of the velocity and pressure was predominantly distributed in the frequency range of 0.00014-0.1 Hz and increased inversely with frequency, indicating characteristics of an inverse power law (1/f(alpha)). However, linear regression on a log-log scale revealed that the slope of spectral power of pressure and velocity was steeper in the high-frequency (0.02-0.5 Hz) than in the low-frequency range (0.002-0.02 Hz), suggesting different regulatory mechanisms in these two frequency ranges. Furthermore, the spectral slope of pressure was significantly steeper than that of velocity in the low-frequency range, consistent with the low transfer function gain and low coherence estimated at these frequencies. We conclude that 1) long-term fluctuations in CBF velocity are prominent and similar to those observed in arterial pressure, 2) spectral power of CBF velocity reveals characteristics of 1/f(alpha), and 3) cerebral attenuation of oscillations in CBF velocity in response to changes in pressure may be more effective at low than that at high frequencies, emphasizing the frequency dependence of cerebral autoregulation.

  20. Quality properties of pre- and post-rigor beef muscle after interventions with high frequency ultrasound.

    PubMed

    Sikes, Anita L; Mawson, Raymond; Stark, Janet; Warner, Robyn

    2014-11-01

    The delivery of a consistent quality product to the consumer is vitally important for the food industry. The aim of this study was to investigate the potential for using high frequency ultrasound applied to pre- and post-rigor beef muscle on the metabolism and subsequent quality. High frequency ultrasound (600kHz at 48kPa and 65kPa acoustic pressure) applied to post-rigor beef striploin steaks resulted in no significant effect on the texture (peak force value) of cooked steaks as measured by a Tenderometer. There was no added benefit of ultrasound treatment above that of the normal ageing process after ageing of the steaks for 7days at 4°C. Ultrasound treatment of post-rigor beef steaks resulted in a darkening of fresh steaks but after ageing for 7days at 4°C, the ultrasound-treated steaks were similar in colour to that of the aged, untreated steaks. High frequency ultrasound (2MHz at 48kPa acoustic pressure) applied to pre-rigor beef neck muscle had no effect on the pH, but the calculated exhaustion factor suggested that there was some effect on metabolism and actin-myosin interaction. However, the resultant texture of cooked, ultrasound-treated muscle was lower in tenderness compared to the control sample. After ageing for 3weeks at 0°C, the ultrasound-treated samples had the same peak force value as the control. High frequency ultrasound had no significant effect on the colour parameters of pre-rigor beef neck muscle. This proof-of-concept study showed no effect of ultrasound on quality but did indicate that the application of high frequency ultrasound to pre-rigor beef muscle shows potential for modifying ATP turnover and further investigation is warranted. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  1. A preliminary analysis of low frequency pressure oscillations in hybrid rocket motors

    NASA Technical Reports Server (NTRS)

    Jenkins, Rhonald M.

    1994-01-01

    Past research with hybrid rockets has suggested that certain motor operating conditions are conducive to the formation of pressure oscillations, or flow instabilities, within the motor combustion chamber. These combustion-related vibrations or pressure oscillations may be encountered in virtually any type of rocket motor and typically fall into three frequency ranges: low frequency oscillations (0-300 Hz); intermediate frequency oscillations (400-1000 Hz); and high frequency oscillations (greater than 1000 Hz). In general, combustion instability is characterized by organized pressure oscillations occurring at well-defined intervals with pressure peaks that may maintain themselves, grow, or die out. Usually, such peaks exceed +/- 5% of the mean chamber pressure. For hybrid motors, these oscillations have been observed to grow to a limiting amplitude which may be dependent on factors such as fuel characteristics, oxidizer injector characteristics, average chamber pressure, oxidizer mass flux, combustion chamber length, and grain geometry. The approach taken in the present analysis is to develop a modified chamber length, L, instability theory which accounts for the relationship between pressure and oxidizer to fuel concentration ratio in the motor.

  2. High-frequency profile in adolescents and its relationship with the use of personal stereo devices.

    PubMed

    Silvestre, Renata Almeida Araújo; Ribas, Ângela; Hammerschmidt, Rogério; de Lacerda, Adriana Bender Moreira

    2016-01-01

    To analyze and correlate the audiometric findings of high frequencies (9-16 kHz) in adolescents with their hearing habits and attitudes, in order to prevent noise-induced hearing loss. This was a descriptive cross-sectional study, which included 125 adolescents in a sample of normal-hearing students, at a state school. The subjects performed high-frequency audiometry testing and answered a self-administered questionnaire addressing information on sound habits concerning the use of personal stereo devices. The sample was divided according to the exposure characteristics (time, duration, intensity, etc.) and the results were compared with the observed thresholds, through the difference in proportions test, chi-squared, Student's t-test, and ANOVA, all at a significance level of 0.05. Average high-frequency thresholds were registered below 15 dB HL and no significant correlation was found between high frequency audiometric findings and the degree of exposure. The prevalence of harmful sound habits due to the use of personal stereo devices is high in the adolescent population, but there was no correlation between exposure to high sound pressure levels through personal stereos and the high-frequency thresholds in this population. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  3. Office blood pressure, heart rate and A(-596)G interleukin-6 gene polymorphism in apparently healthy Czech middle-aged population.

    PubMed

    Vasků, A; Soucek, M; Goldbergová, M; Vácha, J

    2003-01-01

    The aim of the study was to assess the association between promoter polymorphism [A(-596)G] in interleukin-6 gene and office systolic and diastolic blood pressures, and the heart rate (HR) in apparently healthy Czech subjects. Furthermore, we evaluated the possible influence of gender, BMI and smoking on these supposed associations. An age-matched (40-50 years) and gender-matched (F/M=81/89) sample of apparently healthy Czech subjects (n=170, F/M=81/89) without hypertension, other cardiovascular diseases or diabetes was examined. The A(-596)G Il-6 gene polymorphism was detected by the PCR method. No differences in genotype distribution and/or allelic frequency was found between groups with lower systolic blood pressure (Ł 122 mm Hg) and higher systolic blood pressure (> 122 mm Hg). Similarly, no differences in the IL-6 polymorphism were found between lower (Ł 86 mm Hg) and higher (> 86 mm Hg) diastolic blood pressure groups. However, we proved a significant increase of genotypes AG+GG as well as the allele (-596)G in higher (>78 beats/min) heart rate group. The genotypes AG+GG represent significantly higher relative risk for higher HR frequency, especially in women. Among lean persons with a low heart rate frequency, fewer AG+GG genotypes were determined than among any other subjects. The genotypes AG+GG are more frequent in non-smoking persons with higher HR compared to non-smoking subjects with lower HR, especially in women. Gender, BMI and smoking substantially modify the distribution of A(-596)G Il-6 gene polymorphism in apparently healthy persons with lower or higher heart rate.

  4. Correlated environmental corrections in TOPEX/POSEIDON, with a note on ionospheric accuracy

    NASA Technical Reports Server (NTRS)

    Zlotnicki, V.

    1994-01-01

    Estimates of the effectiveness of an altimetric correction, and interpretation of sea level variability as a response to atmospheric forcing, both depend upon assuming that residual errors in altimetric corrections are uncorrelated among themselves and with residual sea level, or knowing the correlations. Not surprisingly, many corrections are highly correlated since they involve atmospheric properties and the ocean surface's response to them. The full corrections (including their geographically varying time mean values), show correlations between electromagnetic bias (mostly the height of wind waves) and either atmospheric pressure or water vapor of -40%, and between atmospheric pressure and water vapor of 28%. In the more commonly used collinear differences (after removal of the geographically varying time mean), atmospheric pressure and wave height show a -30% correlation, atmospheric pressure and water vapor a -10% correlation, both pressure and water vapor a 7% correlation with residual sea level, and a bit surprisingly, ionospheric electron content and wave height a 15% correlation. Only the ocean tide is totally uncorrelated with other corrections or residual sea level. The effectiveness of three ionospheric corrections (TOPEX dual-frequency, a smoothed version of the TOPEX dual-frequency, and Doppler orbitography and radiopositioning integrated by satellite (DORIS) is also evaluated in terms of their reduction in variance of residual sea level. Smooth (90-200 km along-track) versions of the dual-frequency altimeter ionosphere perform best both globally and within 20 deg in latitude from the equator. The noise variance in the 1/s TOPEX inospheric samples is approximately (11 mm) squared, about the same as noise in the DORIS-based correction; however, the latter has its error over scales of order 10(exp 3) km. Within 20 deg of the equator, the DORIS-based correction adds (14 mm) squared to the residual sea level variance.

  5. Digital pressure transducer for use at high temperatures

    DOEpatents

    Karplus, Henry H. B.

    1981-01-01

    A digital pressure sensor for measuring fluid pressures at relatively high temperatures includes an electrically conducting fiber coupled to the fluid by a force disc that causes tension in the fiber to be a function of fluid pressure. The tension causes changes in the mechanical resonant frequency of the fiber, which is caused to vibrate in a magnetic field to produce an electrical signal from a positive-feedback amplifier at the resonant frequency. A count of this frequency provides a measure of the fluid pressure.

  6. Digital pressure transducer for use at high temperatures

    DOEpatents

    Karplus, H.H.B.

    A digital pressure sensor for measuring fluid pressures at relatively high temperatures includes an electrically conducting fiber coupled to the fluid by a force disc that causes tension in the fiber to be a function of fluid pressure. The tension causes changes in the mechanical resonant frequency of the fiber, which is caused to vibrate in a magnetic field to produce an electrical signal from a positive-feedback amplifier at the resonant frequency. A count of this frequency provides a measure of the fluid pressure.

  7. A New Approach for Very Large Broadband Geophysical Monitoring of rock Deformations Into Deep Boreholes: The "High-Pulse Poroelasticity Protocol" (HPPP)

    NASA Astrophysics Data System (ADS)

    Guglielmi, Y.; Cappa, F.; Virieux, J.; Rutqvist, J.; Tsang, C.

    2007-12-01

    We present a new approach, called the "High-Pulse Poroelasticity Protocol" (HPPP), for a very large broadband geophysical monitoring of rock deformations into deep boreholes (from 200 m to 1 km depth). The HPPP consists in developing an innovative probe that allows the hydromechanical loading of rocks with synchronous fluid pressure - 3D deformations (translational components along and in the orthogonal plan of the borehole axis, and rotational components along the longitudinal axis) - seismic wave measurements over a broadband of frequencies (from static to dynamic [1-1,000 Hz]). In this protocol, the rock is subjected to a controlled source corresponding to a fast (few seconds) hydraulic pressure pulse (pressure wave) localized into a short injection chamber (from 1 to 3 m) which is isolated between two inflatable packers in a borehole. In the chamber, measurements are done with fibre-optic and acoustic sensors that makes possible to use a wide range of frequencies (1-1,000 Hz) and high accuracy (10-7) sampling of fluid pressure and 3D deformations. When the pressure wave is applied, several poroelastic effects are measured: (i) a static poroelastic response that is linked to the fluid diffusion in phase with mechanical deformation of the porous rock; (ii) a low-frequency slow Biot wave (P2 wave) associated with the motion out of phase of solid and fluid phases; (iii) a high-frequency pressure wave that is generated and converted to seismic waves (P1 and S waves) at the borehole wall. This new approach aims at determining the infinitesimal shear and axial components of the strain tensor within the rock crossed by a borehole. The HPPP also allows studying the relationships between elastic waves propagation and rock hydromechanical properties and state at an intermediate scale (mesoscopic scale), between the laboratory and crustal scales, in a volume of one to a few tens of meters around the borehole. This new approach was designed from previous pulse testing done in a fault zone with a first prototype of the HPPP probe capable of simultaneously measuring changes (with a high frequency [120 Hz] and high accuracy) in fluid pressure (± 1 kPa) and displacement normal to the fault (± 10-7 m). This prototype consisted of a fibre-optic fluid pressure and a fibre-optic normal displacement sensor fixed to the borehole walls by two anchors located on both sides of the fault which was isolated with two packers to create a 0.4 m injection chamber. Results indicated that fiber-optic measurements allow good capturing of all the high-frequency changes during the hydraulic pulse. The method appears useful for accurately measuring time discrepancies between pressure and deformation signals as small as a few milliseconds. Moreover, high-frequency measurement of the fault "pressure-deformation" poroelastic response allows highlighting of a loop-shaped evolution that is not observed in conventional laboratory or in situ experiments. Consequently, the HPPP approach will provide new data with axial and shear components of the strain tensor which will give us additional information for determination of the rock seismic and hydromechanical properties at various depths in the crust. Moreover, the HPPP will be adapted to study seismic and mechanical instability of fault zones under controlled hydraulic loading and localized in a point source.

  8. A Turbine-Driven Ventilator Improves Adherence to Advanced Cardiac Life Support Guidelines During a Cardiopulmonary Resuscitation Simulation.

    PubMed

    Allen, Scott G; Brewer, Lara; Gillis, Erik S; Pace, Nathan L; Sakata, Derek J; Orr, Joseph A

    2017-09-01

    Research has shown that increased breathing frequency during cardiopulmonary resuscitation is inversely correlated with systolic blood pressure. Rescuers often hyperventilate during cardiopulmonary resuscitation (CPR). Current American Heart Association advanced cardiac life support recommends a ventilation rate of 8-10 breaths/min. We hypothesized that a small, turbine-driven ventilator would allow rescuers to adhere more closely to advanced cardiac life support (ACLS) guidelines. Twenty-four ACLS-certified health-care professionals were paired into groups of 2. Each team performed 4 randomized rounds of 2-min cycles of CPR on an intubated mannikin, with individuals altering between compressions and breaths. Two rounds of CPR were performed with a self-inflating bag, and 2 rounds were with the ventilator. The ventilator was set to deliver 8 breaths/min, pressure limit 22 cm H 2 O. Frequency, tidal volume (V T ), peak inspiratory pressure, and compression interruptions (hands-off time) were recorded. Data were analyzed with a linear mixed model and Welch 2-sample t test. The median (interquartile range [IQR]) frequency with the ventilator was 7.98 (7.98-7.99) breaths/min. Median (IQR) frequency with the self-inflating bag was 9.5 (8.2-10.7) breaths/min. Median (IQR) ventilator V T was 0.5 (0.5-0.5) L. Median (IQR) self-inflating bag V T was 0.6 (0.5-0.7) L. Median (IQR) ventilator peak inspiratory pressure was 22 (22-22) cm H 2 O. Median (IQR) self-inflating bag peak inspiratory pressure was 30 (27-35) cm H 2 O. Mean ± SD hands-off times for ventilator and self-inflating bag were 5.25 ± 2.11 and 6.41 ± 1.45 s, respectively. When compared with a ventilator, volunteers ventilated with a self-inflating bag within ACLS guidelines. However, volunteers ventilated with increased variation, at higher V T levels, and at higher peak pressures with the self-inflating bag. Hands-off time was also significantly lower with the ventilator. (ClinicalTrials.gov registration NCT02743299.). Copyright © 2017 by Daedalus Enterprises.

  9. Photoacoustic tomography using a fiber based Fabry-Perot interferometer as an integrating line detector and image reconstruction by model-based time reversal method

    NASA Astrophysics Data System (ADS)

    Grün, H.; Paltauf, G.; Haltmeier, M.; Burgholzer, P.

    2007-07-01

    Photoacoustic imaging is based on the generation of acoustic waves in a semitransparent sample (e.g. soft tissue) after illumination with short pulses of light or radio waves. The goal is to recover the spatial distribution of absorbed energy density inside the sample from acoustic pressure signals measured outside the sample (photoacoustic inverse problem). If the acoustic pressure outside the illuminated sample is measured with a large-aperture detector, the signal at a certain time is given by an integral of the generated acoustic pressure distribution over an area that is determined by the shape of the detector. For example a planar detector measures the projections of the initial pressure distribution over planes parallel to the detector plane, which is the Radon transform of the initial pressure distribution. Stable and exact three-dimensional imaging with planar integrating detector requires measurements in all directions of space and so the receiver plane has to be rotated to cover the entire detection surface. We have recently presented a simpler set-up for exact imaging which requires only a single rotation axis and therefor the fragmentation of the area detector into line detectors perpendicular to the rotation axis. Using a two-dimensional reconstruction method and applying the inverse two-dimensional Radon transform afterwards gives an exact reconstruction of the three-dimensional sample with this set-up. In order to achieve high resolution, a fiber based Fabry-Perot interferometer is used. It is a single mode fiber with two fiber bragg gratings on both ends of the line detector. Thermal shifts and vibrations are compensated by frequency locking of the laser. The high resolution and the good performance of this integrating line detector has been demonstrated by photoacoustic measurements with line grid samples and phantoms using a model-based time reversal method for image reconstruction. The time reversed pressure field can be calculated directly by retransmitting the measured pressure on the detector positions in a reversed temporal order.

  10. Acoustic waves in gases with strong pressure gradients

    NASA Technical Reports Server (NTRS)

    Zorumski, William E.

    1989-01-01

    The effect of strong pressure gradients on the acoustic modes (standing waves) of a rectangular cavity is investigated analytically. When the cavity response is represented by a sum of modes, each mode is found to have two resonant frequencies. The lower frequency is near the Viaesaela-Brundt frequency, which characterizes the buoyant effect, and the higher frequency is above the ordinary acoustic resonance frequency. This finding shows that the propagation velocity of the acoustic waves is increased due to the pressure gradient effect.

  11. Dynamic characteristic investigation on the fuel pressure of diesel engines electronic in-line pump system

    NASA Astrophysics Data System (ADS)

    Liu, You; Yuan, Zhi-Guo; Fan, Li-Yun; Tian, Bin-Qi

    2010-12-01

    The electronic in-line pump (EIP) is a complex system consisting of mechanical, hydraulic, and electromagnetic parts. Experimental study showed that the fuel pressure of the plunger and the fuel drainage of the pressure system after fuel injection could result in fuel pressure fluctuation in the low pressure system. Such fluctuation exhibited pulsating cycle fluctuation as the amplitude rose with the increase of the injection pulse width. The time domain analysis found that the pressure time history curve and injection cylinders corresponded with a one-to-one relationship. By frequency domain analysis, the result was that with the increase of the working cylinder number, the high frequency amplitude gradually increased and the basic frequency amplitude gradually decreased. The conclusion was that through wavelet transformation, the low pressure signal simultaneously moved towards low frequency as the high frequency of the wavelet transformation signal with the working cylinder number increased. Lastly, by using the numerical model, the study investigated the simulation research concerning the relationship of the fluctuation dynamic characteristic in the low pressure system and the fuel injection characteristic of the high pressure system, completing the conclusions obtained by the experimental study.

  12. Growth of vertically aligned carbon nanofibers by low-pressure inductively coupled plasma-enhanced chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Caughman, J. B. O.; Baylor, L. R.; Guillorn, M. A.; Merkulov, V. I.; Lowndes, D. H.; Allard, L. F.

    2003-08-01

    Vertically aligned carbon nanofibers (VACNFs) have been grown using a low-pressure, plasma-enhanced, chemical vapor deposition process. The nanofibers are grown from a nickel catalyst that can be patterned to form arrays of individual, isolated VACNFs. The fibers are grown at pressures below 100 mTorr, using an inductively coupled plasma source with a radio-frequency bias on the sample substrate to allow for independent control of the ion energies. Plasma conditions are related to growth results by comparing optical emission from the plasma to the physical structure of the nanofibers. We find that the ratio of etching species in the plasma to depositing species is critical to the final shape of the carbon structures that are formed.

  13. Investigation of low-frequency-oscillating water flow in metal foam with 10 pores per inch

    NASA Astrophysics Data System (ADS)

    Bağcı, Ö.; Arbak, A.; De Paepe, M.; Dukhan, N.

    2018-01-01

    In this study, oscillating water flow in metal foam with open cells is investigated experimentally. The metal foam sample has a porosity of 88% and 10 pores. The water was oscillated in the test section with three frequencies between 0.116 Hz and 0.348 Hz, which are considered low for water oscillation, and three flow displacements ranging between 74.35 mm and 111.53 mm. The combinations of frequencies of displacements were studied for their impacts of dimensional and non-dimensional pressure loss quantities. To this purpose, friction factor was correlated as a function of kinetic Reynolds number. The same metal foam sample was studied by exposing it to steady-state water flow to investigate its permeability and drag coefficient in low-velocity flow regimes. The friction factor distribution for oscillating flow was found to be over that found for steady state. The outcomes of the study are important for studying heat transfer under the same flow conditions.

  14. Numerical study on the instabilities in H2-air rotating detonation engines

    NASA Astrophysics Data System (ADS)

    Liu, Yan; Zhou, Weijiang; Yang, Yunjun; Liu, Zhou; Wang, Jianping

    2018-04-01

    Numerical simulations of rotating detonation engines (RDEs) are performed using two-dimensional Euler equations and a detailed chemistry model of H2-air. Two propagation modes, the one-wave mode and the two-wave mode, are observed in the RDEs. The instabilities of the RDEs are studied and analyzed specifically. A low frequency instability and a high frequency instability are found from the pressure-time trace measured at a fixed location and the average density-time trace of the RDEs. For the low frequency instability, the pressure peak of the pressure-time trace oscillates with a low frequency while the average density is stable. The deviation between the measurement location and the location of the detonation wave results in the low frequency instability. For the high frequency instability, the average density of the RDEs oscillates regularly with a single frequency while the pressure oscillates irregularly with several frequencies. The oscillation of the detonation wave height results in the high frequency instability. Furthermore, the low frequency instability and the high frequency instability both occur in the one-wave and two-wave mode RDEs.

  15. Influence of Pressure Field in Melts on the Primary Nucleation in Solidification Processing

    NASA Astrophysics Data System (ADS)

    Rakita, Milan; Han, Qingyou

    2017-10-01

    It is well known that external fields applied to melts can cause nucleation at lower supercoolings, fragmentation of growing dendrites, and forced convection around the solidification front. All these effects contribute to a finer microstructure of solidified material. In this article, we analyze how the pressure field created with ultrasonic vibrations influences structure refinement in terms of supercooling. It is shown that only high cavitation pressures of the order of 104 atmospheres are capable of nucleating crystals at minimal supercoolings. We demonstrate the possibility of sononucleation even in superheated liquid. Simulation and experiments with water samples show that very high cavitation pressures occur in a relatively narrow zone where the drive acoustic field has an appropriate combination of pressure amplitude and frequency. In order to accurately predict the microstructure formed by ultrasonically assisted solidification of metals, this article calls for the development of equations of state that would describe the pressure-dependent behavior of molten metals.

  16. High-sensitivity NMR beyond 200,000 atmospheres of pressure

    NASA Astrophysics Data System (ADS)

    Meier, T.; Reichardt, S.; Haase, J.

    2015-08-01

    Pressure-induced changes in the chemical or electronic structure of solids require pressures well into the Giga-Pascal (GPa) range due to the strong bonding. Anvil cell designs can reach such pressures, but their small and mostly inaccessible sample chamber has severely hampered NMR experiments in the past. With a new cell design that has a radio frequency (RF) micro-coil in the high pressure chamber, NMR experiments beyond 20 Giga-Pascal are reported for the first time. 1 H NMR of water shows sensitivity and resolution obtained with the cells, and 63 Cu NMR on a cuprate superconductor (YBa2Cu3O7-δ) demonstrates that single-crystals can be investigated, as well. 115 In NMR of the ternary chalcogenide AgInTe2 discovers an insulator-metal transition with shift and relaxation measurements. The pressure cells can be mounted easily on standard NMR probes that fit commercial wide-bore magnets with regular cryostats for field- and temperature-dependent measurements ready for many applications in physics and chemistry.

  17. Nonequilibrium atmospheric pressure plasma jet using a combination of 50 kHz/2 MHz dual-frequency power sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Yong-Jie; Yuan, Qiang-Hua; Li, Fei

    2013-11-15

    An atmospheric pressure plasma jet is generated by dual sinusoidal wave (50 kHz and 2 MHz). The dual-frequency plasma jet exhibits the advantages of both low frequency and radio frequency plasmas, namely, the long plasma plume and the high electron density. The radio frequency ignition voltage can be reduced significantly by using dual-frequency excitation compared to the conventional radio frequency without the aid of the low frequency excitation source. A larger operating range of α mode discharge can be obtained using dual-frequency excitation which is important to obtain homogeneous and low-temperature plasma. A larger controllable range of the gas temperaturemore » of atmospheric pressure plasma could also be obtained using dual-frequency excitation.« less

  18. Pressure broadening and frequency shift of the D 1 and D 2 lines of K in the presence of Ne and Kr

    NASA Astrophysics Data System (ADS)

    Wang, Xulin; Chen, Yao; Quan, Wei; Chi, Haotian; Fang, Jiancheng

    2018-02-01

    We present the results of pressure broadening and frequency shift of K D 1 and D 2 lines in presence of 1-4 amg of Neon gas and 1-5 amg of Krypton gas by laser absorption spectroscopy. Both pressure broadening and frequency shift are linearly related to gas density with high accuracy. The asymmetry of the absorption line shape caused by van der Waals potential was first found in the near-line wings of large density Kr in the experiment. We have also investigated the temperature dependence of the pressure broadening and frequency shift in a range of 353-403 K in Neon and 373-417 K in Krypton and compared the results of the pressure broadening and frequency shift with previous values.

  19. Velocity measurement using frequency domain interferometer and chirped pulse laser

    NASA Astrophysics Data System (ADS)

    Ishii, K.; Nishimura, Y.; Mori, Y.; Hanayama, R.; Kitagawa, Y.; Sekine, T.; Sato, N.; Kurita, T.; Kawashima, T.; Sunahara, A.; Sentoku, Y.; Miura, E.; Iwamoto, A.; Sakagami, H.

    2017-02-01

    An ultra-intense short pulse laser induces a shock wave in material. The pressure of shock compression is stronger than a few tens GPa. To characterize shock waves, time-resolved velocity measurement in nano- or pico-second time scale is needed. Frequency domain interferometer and chirped pulse laser provide single-shot time-resolved measurement. We have developed a laser-driven shock compression system and frequency domain interferometer with CPA laser. In this paper, we show the principle of velocity measurement using a frequency domain interferometer and a chirped pulse laser. Next, we numerically calculated spectral interferograms and show the time-resolved velocity measurement can be done from the phase analysis of spectral interferograms. Moreover we conduct the laser driven shock generation and shock velocity measurement. From the spectral fringes, we analyze the velocities of the sample and shockwaves.

  20. Dynamic Cerebral Autoregulation is Preserved During Acute Head-down Tilt

    DTIC Science & Technology

    2003-06-27

    relationship of mean arterial pressure to mean cerebral blood flow velocity transfer function gain at the high and low frequencies, respectively; TCD-PHASE...HF and TCD-PHASE-LF, phase angle between mean arterial pressure and mean cerebral blood flow veloc- ity at high and low frequencies, respectively...arterial pressure and mean ce- rebral blood flow oscillations decrease from low- to high -frequency ranges. Average phase angles were 68° at low frequencies

  1. A study of the eigenvectors of the vibrational modes in crystalline cytidine via high-pressure Raman spectroscopy.

    PubMed

    Lee, Scott A; Pinnick, David A; Anderson, A

    2015-01-01

    Raman spectroscopy has been used to study the eigenvectors and eigenvalues of the vibrational modes of crystalline cytidine at 295 K and high pressures by evaluating the logarithmic derivative of the vibrational frequency ω with respect to pressure P: [Formula: see text]. Crystalline samples of molecular materials have strong intramolecular bonds and weak intermolecular bonds. This hierarchy of bonding strengths causes the vibrational optical modes localized within a molecular unit ("internal" modes) to be relatively high in frequency while the modes in which the molecular units vibrate against each other ("external" modes) have relatively low frequencies. The value of the logarithmic derivative is a useful diagnostic probe of the nature of the eigenvector of the vibrational modes because stretching modes (which are predominantly internal to the molecule) have low logarithmic derivatives while external modes have higher logarithmic derivatives. In crystalline cytidine, the modes at 85.8, 101.4, and 110.6 cm(-1) are external in which the molecules of the unit cell vibrate against each other in either translational or librational motions (or some linear combination thereof). All of the modes above 320 cm(-1) are predominantly internal stretching modes. The remaining modes below 320 cm(-1) include external modes and internal modes, mostly involving either torsional or bending motions of groups of atoms within a molecule.

  2. Social integration, social contacts, and blood pressure dipping in African-Americans and whites.

    PubMed

    Troxel, Wendy M; Buysse, Daniel J; Hall, Martica; Kamarck, Thomas W; Strollo, Patrick J; Owens, Jane F; Reis, Steven E; Matthews, Karen A

    2010-02-01

    Both the size and diversity of an individual's social network are strongly and prospectively linked with cardiovascular morbidity and mortality. Social relationships may influence cardiovascular outcomes, at least in part, via their impact on physiologic pathways influenced by stress, such as daytime blood pressure (BP) levels. However, scant research has examined whether social relationships influence key nocturnal pathways, such as nocturnal BP dipping. The current study examined the degree to which social integration, as measured by participants' reported engagement in a range of different types of social relationships, and the frequency of daily social contacts influence the ratio of night/day mean arterial pressure (MAP) in a community sample of African-American and white men and women (N = 224). In addition, we examined the degree to which observed associations persisted after statistical adjustment for factors known to covary with nocturnal BP, including objective measures of sleep, catecholamines, health behaviors, and comorbidities. In fully adjusted models, there was a significant association between both social integration and frequency of social contacts and the ratio of night/day MAP, indicating that socially isolated individuals were more likely to have blunted nocturnal BP-dipping profiles. There was also a significant interaction between social contact frequency and ethnicity, suggesting that the benefits of social relationships were particularly evident in African-Americans. These findings contribute to our understanding of how social integration or conversely, social isolation, influences cardiovascular risk.

  3. On pressure-frequency relations in the excised larynx.

    PubMed

    Alipour, Fariborz; Scherer, Ronald C

    2007-10-01

    The purpose of this study was to find relationships between subglottal pressure (P(s)) and fundamental frequency (F(0)) of phonation in excised larynx models. This included also the relation between F(0) and its rate of change with pressure (dFdP). Canine larynges were prepared and mounted over a tapered tube that supplied pressurized, heated, and humidified air. Glottal adduction was accomplished either by using two-pronged probes to press the arytenoids together or by passing a suture to simulate lateral cricoarytenoid muscle activation. The pressure-frequency relation was obtained through a series of pressure-flow sweep experiments that were conducted for eight excised canine larynges. It was found that, at set adduction and elongation levels, the pressure-frequency relation is nonlinear, and is highly influenced by the adduction and elongation. The results indicated that for the lower phonation mode, the average rate of change of frequency with pressure was 2.9+/-0.7 Hzcm H(2)O, and for the higher mode was 5.3+/-0.5 Hzcm H(2)O for adduction changes and 8.2+/-4.4 Hzcm H(2)O for elongation changes. The results suggest that during speech and singing, the dFdP relationships are taken into account.

  4. Frequency Modulation and Spatiotemporal Stability of the sCPG in Preterm Infants with RDS

    PubMed Central

    Barlow, Steven M.; Burch, Mimi; Venkatesan, Lalit; Harold, Meredith; Zimmerman, Emily

    2012-01-01

    The nonnutritive suck (NNS) is an observable and accessible motor behavior which is often used to make inference about brain development and pre-feeding skill in preterm and term infants. The purpose of this study was to model NNS burst compression pressure dynamics in the frequency and time domain among two groups of preterm infants, including those with respiratory distress syndrome (RDS, N = 15) and 17 healthy controls. Digitized samples of NNS compression pressure waveforms recorded at a 1-week interval were collected 15 minutes prior to a scheduled feed. Regression analysis and ANOVA revealed that healthy preterm infants produced longer NNS bursts and the mean burst initiation cycle frequencies were higher when compared to the RDS group. Moreover, the initial 5 cycles of the NNS burst manifest a frequency modulated (FM) segment which is a significant feature of the suck central pattern generator (sCPG), and differentially expressed in healthy and RDS infants. The NNS burst structure revealed significantly lower spatiotemporal index values for control versus RDS preterm infants during FM, and provides additional information on the microstructure of the sCPG which may be used to gauge the developmental status and progression of oromotor control systems among these fragile infants. PMID:22888359

  5. Simulation of rarefied low pressure RF plasma flow around the sample

    NASA Astrophysics Data System (ADS)

    Zheltukhin, V. S.; Shemakhin, A. Yu

    2017-01-01

    The paper describes a mathematical model of the flow of radio frequency plasma at low pressure. The hybrid mathematical model includes the Boltzmann equation for the neutral component of the RF plasma, the continuity and the thermal equations for the charged component. Initial and boundary conditions for the corresponding equations are described. The electron temperature in the calculations is 1-4 eV, atoms temperature in the plasma clot is (3-4) • 103 K, in the plasma jet is (3.2-10) • 102 K, the degree of ionization is 10-7-10-5, electron density is 1015-1019 m-3. For calculations plasma parameters is developed soft package on C++ program language, that uses the OpenFOAM library package. Simulations for the vacuum chamber in the presence of a sample and the free jet flow were carried out.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gamboa, E. J.; Fletcher, L. B.; Lee, H. J.

    The extraordinary mechanical and optical properties of diamond are the basis of numerous technical applications and make diamond anvil cells a premier device to explore the high-pressure behavior of materials. However, at applied pressures above a few hundred GPa, optical probing through the anvils becomes difficult because of the pressure-induced changes of the transmission and the excitation of a strong optical emission. Such features have been interpreted as the onset of a closure of the optical gap in diamond, and can significantly impair spectroscopy of the material inside the cell. In contrast, a comparable widening has been predicted for purelymore » hydrostatic compressions, forming a basis for the presumed pressure stiffening of diamond and resilience to the eventual phase change to BC8. We here present the first experimental evidence of this effect at geo-planetary pressures, exceeding the highest ever reported hydrostatic compression of diamond by more than 200 GPa and any other measurement of the band gap by more than 350 GPa. We here apply laser driven-ablation to create a dynamic, high pressure state in a thin, synthetic diamond foil together with frequency-resolved x-ray scattering as a probe. The frequency shift of the inelastically scattered x-rays encodes the optical properties and, thus, the behavior of the band gap in the sample. Using the ultra-bright x-ray beam from the Linac Coherent Light Source (LCLS), we observe an increasing direct band gap in diamond up to a pressure of 370 GPa. This finding points to the enormous strains in the anvils and the impurities in natural Type Ia diamonds as the source of the observed closure of the optical window. Our results demonstrate that diamond remains an insulating solid to pressures approaching its limit strength.« less

  7. Modeling subharmonic response from contrast microbubbles as a function of ambient static pressure

    PubMed Central

    Katiyar, Amit; Sarkar, Kausik; Forsberg, Flemming

    2011-01-01

    Variation of subharmonic response from contrast microbubbles with ambient pressure is numerically investigated for non-invasive monitoring of organ-level blood pressure. Previously, several contrast microbubbles both in vitro and in vivo registered approximately linear (5–15 dB) subharmonic response reduction with 188 mm Hg change in ambient pressure. In contrast, simulated subharmonic response from a single microbubble is seen here to either increase or decrease with ambient pressure. This is shown using the code BUBBLESIM for encapsulated microbubbles, and then the underlying dynamics is investigated using a free bubble model. The ratio of the excitation frequency to the natural frequency of the bubble is the determining parameter—increasing ambient pressure increases natural frequency thereby changing this ratio. For frequency ratio below a lower critical value, increasing ambient pressure monotonically decreases subharmonic response. Above an upper critical value of the same ratio, increasing ambient pressure increases subharmonic response; in between, the subharmonic variation is non-monotonic. The precise values of frequency ratio for these three different trends depend on bubble radius and excitation amplitude. The modeled increase or decrease of subharmonic with ambient pressure, when one happens, is approximately linear only for certain range of excitation levels. Possible reasons for discrepancies between model and previous experiments are discussed. PMID:21476688

  8. Comparing otoacoustic emissions evoked by chirp transients with constant absorbed sound power and constant incident pressure magnitude.

    PubMed

    Keefe, Douglas H; Feeney, M Patrick; Hunter, Lisa L; Fitzpatrick, Denis F

    2017-01-01

    Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz.

  9. Streaming Potential In Rocks Saturated With Water And Oil

    NASA Astrophysics Data System (ADS)

    Tarvin, J. A.; Caston, A.

    2011-12-01

    Fluids flowing through porous media generate electrical currents. These currents cause electric potentials, called "streaming potentials." Streaming potential amplitude depends on the applied pressure gradient, on rock and fluid properties, and on the interaction between rock and fluid. Streaming potential has been measured for rocks saturated with water (1) and with water-gas mixtures. (2) Few measurements (3) have been reported for rocks saturated with water-oil mixtures. We measured streaming potential for sandstone and limestone saturated with a mixture of brine and laboratory oil. Cylindrical samples were initially saturated with brine and submerged in oil. Saturation was changed by pumping oil from one end of a sample to the other and then through the sample in the opposite direction. Saturation was estimated from sample resistivity. The final saturation of each sample was determined by heating the sample in a closed container and measuring the pressure. Measurements were made by modulating the pressure difference (of oil) between the ends of a sample at multiple frequencies below 20 Hz. The observed streaming potential is a weak function of the saturation. Since sample conductivity decreases with increasing oil saturation, the electro-kinetic coupling coefficient (Pride's L (4)) decreases with increasing oil saturation. (1) David B. Pengra and Po-zen Wong, Colloids and Surfaces, vol., p. 159 283-292 (1999). (2) Eve S. Sprunt, Tony B. Mercer, and Nizar F. Djabbarah, Geophysics, vol. 59, p. 707-711 (1994). (3) Vinogradov, J., Jackson, M.D., Geophysical Res. L., Vol. 38, Article L01301 (2011). (4) Steve Pride, Phys. Rev. B, vol. 50, pp. 15678-15696 (1994).

  10. Reliability Advancement for Electronic Engine Controllers. Volume 1

    DTIC Science & Technology

    1980-06-01

    natural frequency increases. Hence, the natural frequency is dependent upon pressure in the nonlinear rela- tionship: Pressure = A + Bft + Cft 2 + Dft 3...Hence, the natural frequency is dependent upon pressure in the nonlinear re- I ationship: Pressure = A + Bft + Cft 2 + Dft 3 + Eft 4 where A, B, C, D...BIT STTE TO’, AML ’’E ICONVERTER ICOUNTER BUFFE CPUT IBUS TOAMPLIFIER________IBUS PROGRAM-COKRSE -TT PER:OO INPUTS ENABLE M MR- - L

  11. Quality of Parent-Child Relationship, Family Conflict, Peer Pressure, and Drinking Behaviors of Adolescents in an Asian Context: The Case of Singapore

    ERIC Educational Resources Information Center

    Choo, Hyekyung; Shek, Daniel

    2013-01-01

    Analyzing data from a probability sample representative of secondary school students in Singapore (N = 1,599), this study examined the independent impact between the quality of mother-child relationship, the quality of father-child relationship and family conflict on the frequency of drinking and drunkenness, and whether each dyadic parent-child…

  12. Frequency analysis of a step dynamic pressure calibrator.

    PubMed

    Choi, In-Mook; Yang, Inseok; Yang, Tae-Heon

    2012-09-01

    A dynamic high pressure standard is becoming more essential in the fields of mobile engines, space science, and especially the area of defense such as long-range missile development. However, a complication arises when a dynamic high pressure sensor is compared with a reference dynamic pressure gauge calibrated in static mode. Also, it is difficult to determine a reference dynamic pressure signal from the calibrator because a dynamic high pressure calibrator generates unnecessary oscillations in a positive-going pressure step method. A dynamic high pressure calibrator, using a quick-opening ball valve, generates a fast step pressure change within 1 ms; however, the calibrator also generates a big impulse force that can lead to a short life-time of the system and to oscillating characteristics in response to the dynamic sensor to be calibrated. In this paper, unnecessary additional resonant frequencies besides those of the step function are characterized using frequency analysis. Accordingly, the main sources of resonance are described. In order to remove unnecessary frequencies, the post processing results, obtained by a filter, are given; also, a method for the modification of the dynamic calibration system is proposed.

  13. Frequency analysis of a step dynamic pressure calibrator

    NASA Astrophysics Data System (ADS)

    Choi, In-Mook; Yang, Inseok; Yang, Tae-Heon

    2012-09-01

    A dynamic high pressure standard is becoming more essential in the fields of mobile engines, space science, and especially the area of defense such as long-range missile development. However, a complication arises when a dynamic high pressure sensor is compared with a reference dynamic pressure gauge calibrated in static mode. Also, it is difficult to determine a reference dynamic pressure signal from the calibrator because a dynamic high pressure calibrator generates unnecessary oscillations in a positive-going pressure step method. A dynamic high pressure calibrator, using a quick-opening ball valve, generates a fast step pressure change within 1 ms; however, the calibrator also generates a big impulse force that can lead to a short life-time of the system and to oscillating characteristics in response to the dynamic sensor to be calibrated. In this paper, unnecessary additional resonant frequencies besides those of the step function are characterized using frequency analysis. Accordingly, the main sources of resonance are described. In order to remove unnecessary frequencies, the post processing results, obtained by a filter, are given; also, a method for the modification of the dynamic calibration system is proposed.

  14. Subglottal pressure and fundamental frequency control in contact calls of juvenile Alligator mississippiensis

    PubMed Central

    Riede, Tobias; Tokuda, Isao T.; Farmer, C. G.

    2011-01-01

    SUMMARY Vocalization is rare among non-avian reptiles, with the exception of the crocodilians, the sister taxon of birds. Crocodilians have a complex vocal repertoire. Their vocal and respiratory system is not well understood but appears to consist of a combination of features that are also found in the extremely vocal avian and mammalian taxa. Anatomical studies suggest that the alligator larynx is able to abduct and adduct the vocal folds, but not to elongate or shorten them, and is therefore lacking a key regulator of frequency, yet alligators can modulate fundamental frequency remarkably well. We investigated the morphological and physiological features of sound production in alligators. Vocal fold length scales isometrically across a wide range of alligator body sizes. The relationship between fundamental frequency and subglottal pressure is significant in some individuals at some isolated points, such as call onset and position of maximum fundamental frequency. The relationship is not consistent over large segments of the call. Fundamental frequency can change faster than expected by pressure changes alone, suggesting an active motor pattern controls frequency and is intrinsic to the larynx. We utilized a two-mass vocal fold model to test whether abduction and adduction could generate this motor pattern. The fine-tuned interplay between subglottal pressure and glottal adduction can achieve frequency modulations much larger than those resulting from subglottal pressure variations alone and of similar magnitude, as observed in alligator calls. We conclude that the alligator larynx represents a sound source with only two control parameters (subglottal pressure and vocal fold adduction) in contrast to the mammalian larynx in which three parameters can be altered to modulate frequency (subglottal pressure, vocal fold adduction and length/tension). PMID:21865521

  15. AC calorimetry of H2O at pressures up to 9 GPa in diamond anvil cells

    NASA Astrophysics Data System (ADS)

    Geballe, Zachary M.; Struzhkin, Viktor V.

    2017-06-01

    If successfully developed, calorimetry at tens of GPa of pressure could help characterize phase transitions in materials such as high-pressure minerals, metals, and molecular solids. Here, we extend alternating-current calorimetry to 9 GPa and 300 K in a diamond anvil cell and use it to study phase transitions in H2O. In particular, water is loaded into the sample chambers of diamond-cells, along with thin metal heaters (1 μm-thick platinum or 20 nm-thick gold on a glass substrate) that drive high-frequency temperature oscillations (20 Hz to 600 kHz; 1 to 10 K). The heaters also act as thermometers via the third-harmonic technique, yielding calorimetric data on (1) heat conduction to the diamonds and (2) heat transport into substrate and sample. Using this method during temperature cycles from 300 to 200 K, we document melting, freezing, and proton ordering and disordering transitions of H2O at 0 to 9 GPa, and characterize changes in thermal conductivity and heat capacity across these transitions. The technique and analysis pave the way for calorimetry experiments on any non-metal at pressures up to ˜100 GPa, provided a thin layer (several μm-thick) of thermal insulation supports a metallic thin-film (tens of nm thick) Joule-heater attached to low contact resistance leads inside the sample chamber of a diamond-cell.

  16. Pressure-induced transformations of nitrogen implanted into silicon

    NASA Astrophysics Data System (ADS)

    Akhmetov, V. D.; Misiuk, A.; Barcz, A.; Richter, H.

    2006-03-01

    Czochralski (CZ) Si samples implanted with nitrogen, with doses 1017 ion/cm2 and 1018 ion/cm2, at 140 keV, were studied by means of Fourier transform infrared spectroscopy after annealing at 1130 °C/5 h under different hydrostatic pressures, from 1 bar to 10.7 kbar. It has been found for each pressure applied, that the increased nitrogen dose leads to transformation of the broadband spectra to the fine structure ones, corresponding to crystalline silicon nitride. The spectral position of observed sharp peaks in the investigated pressure region is red shifted in comparison to that for the peaks of crystalline silicon oxynitride found recently by other investigators in nitrogen-containing poly-Si as well as in a residual melt of nitrogen-doped CZ-Si. The application of the pressure during annealing results in further red shift of the nitrogen-related bands. The observed decrease of frequency of vibrational bands is explained in terms of the pressure induced lowered incorporation of oxygen into growing oxynitride phase. Secondary ion mass spectrometry data reveal the decrease of oxygen content in implanted layer with increasing pressure during annealing.

  17. Assessing complexity of skin blood flow oscillations in response to locally applied heating and pressure in rats: Implications for pressure ulcer risk

    NASA Astrophysics Data System (ADS)

    Liao, Fuyuan; O'Brien, William D.; Jan, Yih-Kuen

    2013-10-01

    The objective of this study was to investigate the effects of local heating on the complexity of skin blood flow oscillations (BFO) under prolonged surface pressure in rats. Eleven Sprague-Dawley rats were studied: 7 rats underwent surface pressure with local heating (△t=10 °C) and 4 rats underwent pressure without heating. A pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin blood flow was measured using laser Doppler flowmetry. The loading period was divided into nonoverlapping 30 min epochs. For each epoch, multifractal detrended fluctuation analysis (MDFA) was utilized to compute DFA coefficients and complexity of endothelial related metabolic, neurogenic, and myogenic frequencies of BFO. The results showed that under surface pressure, local heating led to a significant decrease in DFA coefficients of myogenic frequency during the initial epoch of loading period, a sustained decrease in complexity of myogenic frequency, and a significantly higher degree of complexity of metabolic frequency during the later phase of loading period. Surrogate tests showed that the reduction in complexity of myogenic frequency was associated with a loss of nonlinearity whereas increased complexity of metabolic frequency was associated with enhanced nonlinearity. Our results indicate that increased metabolic activity and decreased myogenic response due to local heating manifest themselves not only in magnitudes of metabolic and myogenic frequencies but also in their structural complexity. This study demonstrates the feasibility of using complexity analysis of BFO to monitor the ischemic status of weight-bearing skin and risk of pressure ulcers.

  18. How to measure heat capacity of metals at 10s to 100s of GPa

    NASA Astrophysics Data System (ADS)

    Geballe, Z. M.; Townley, A.; Jeanloz, R.

    2014-12-01

    Adapting methods of calorimetry to the diamond-anvil cell can provide important new information for understanding planetary interiors. Here we show that heat capacity of metals can be measured to the 10-100 GPa range by using AC electrical heating inside diamond anvil cells. Frequencies of f ≈ 1-100 MHz must be used to contain the heat within the sample of interest, as evidenced by numerical and physical models of heat flow: f > DinsCins2/(Csamdsam)2, where Dins is the thermal diffusivity of the insulation, Cins and Csam are specific heat capacities of insulation and metal sample, and dsam is sample thickness. Heat must be deposited uniformly (e.g. skin depth > sample thickness) for the most accurate and unambiguous measurements, thereby allowing measurement of the energetics of pre-melting, melting and partial melting of metals, including iron and its alloys. In principle, high-pressure calorimetry can be used to independently determine melting at high pressures, and also to quantify latent heats of fusion, thereby revealing the density of liquid metals at Earth core conditions.

  19. Miniature piezoresistive solid state integrated pressure sensors

    NASA Technical Reports Server (NTRS)

    Kahng, S. K.

    1980-01-01

    The characteristics of silicon pressure sensors with an ultra-small diaphragm are described. The pressure sensors utilize rectangular diaphragm as small as 0.0127 x 0.0254 cm and a p-type Wheatstone bridge consisting of diffused piezoresistive elements, 0.000254 cm by 0.00254 cm. These sensors exhibit as high as 0.5 MHz natural frequency and 1 mV/V/psi pressure sensitivity. Fabrication techniques and high frequency results from shock tube testing and low frequency comparison with microphones are presented.

  20. Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure

    DOEpatents

    Sinha, Dipen N.; Wray, William O.

    1994-01-01

    Apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established.

  1. Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure

    DOEpatents

    Sinha, D.N.; Wray, W.O.

    1994-12-27

    The apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established. 3 figures.

  2. Noise and Complexity in Human Postural Control: Interpreting the Different Estimations of Entropy

    PubMed Central

    Rhea, Christopher K.; Silver, Tobin A.; Hong, S. Lee; Ryu, Joong Hyun; Studenka, Breanna E.; Hughes, Charmayne M. L.; Haddad, Jeffrey M.

    2011-01-01

    Background Over the last two decades, various measures of entropy have been used to examine the complexity of human postural control. In general, entropy measures provide information regarding the health, stability and adaptability of the postural system that is not captured when using more traditional analytical techniques. The purpose of this study was to examine how noise, sampling frequency and time series length influence various measures of entropy when applied to human center of pressure (CoP) data, as well as in synthetic signals with known properties. Such a comparison is necessary to interpret data between and within studies that use different entropy measures, equipment, sampling frequencies or data collection durations. Methods and Findings The complexity of synthetic signals with known properties and standing CoP data was calculated using Approximate Entropy (ApEn), Sample Entropy (SampEn) and Recurrence Quantification Analysis Entropy (RQAEn). All signals were examined at varying sampling frequencies and with varying amounts of added noise. Additionally, an increment time series of the original CoP data was examined to remove long-range correlations. Of the three measures examined, ApEn was the least robust to sampling frequency and noise manipulations. Additionally, increased noise led to an increase in SampEn, but a decrease in RQAEn. Thus, noise can yield inconsistent results between the various entropy measures. Finally, the differences between the entropy measures were minimized in the increment CoP data, suggesting that long-range correlations should be removed from CoP data prior to calculating entropy. Conclusions The various algorithms typically used to quantify the complexity (entropy) of CoP may yield very different results, particularly when sampling frequency and noise are different. The results of this study are discussed within the context of the neural noise and loss of complexity hypotheses. PMID:21437281

  3. Fluidic hydrogen detector production prototype development

    NASA Technical Reports Server (NTRS)

    Roe, G. W.; Wright, R. E.

    1976-01-01

    A hydrogen gas sensor that can replace catalytic combustion sensors used to detect leaks in the liquid hydrogen transfer systems at Kennedy Space Center was developed. A fluidic sensor concept, based on the principle that the frequency of a fluidic oscillator is proportional to the square root of the molecular weight of its operating fluid, was utilized. To minimize sensitivity to pressure and temperature fluctuations, and to make the sensor specific for hydrogen, two oscillators are used. One oscillator operates on sample gas containing hydrogen, while the other operates on sample gas with the hydrogen converted to steam. The conversion is accomplished with a small catalytic converter. The frequency difference is taken, and the hydrogen concentration computed with a simple digital processing circuit. The output from the sensor is an analog signal proportional to hydrogen content. The sensor is shown to be accurate and insensitive to severe environmental disturbances. It is also specific for hydrogen, even with large helium concentrations in the sample gas.

  4. Pressure-induced phase transition and fracture in α-MoO3 nanoribbons

    NASA Astrophysics Data System (ADS)

    Silveira, Jose V.; Vieira, Luciana L.; Aguiar, Acrisio L.; Freire, Paulo T. C.; Mendes Filho, Josue; Alves, Oswaldo L.; Souza Filho, Antonio G.

    2018-03-01

    MoO3 nanoribbons were studied under different pressure conditions ranging from 0 to 21 GPa at room temperature. The effect of the applied pressure on the spectroscopic and morphologic properties of the MoO3 nanoribbons was investigated by means of Raman spectroscopy and scanning electron microscopy techniques. The pressure dependent Raman spectra of the MoO3 nanoribbons indicate that a structural phase transition occurs at 5 GPa from the orthorhombic α-MoO3 phase (Pbnm) to the monoclinic MoO3-II phase (P21/m), which remains stable up to 21 GPa. Such phase transformation occurs at considerably lower pressure than the critical pressure for α-MoO3 microcrystals (12 GPa). We suggested that the applanate morphology combined with the presence of crystalline defects in the sample play an important role in the phase transition of the MoO3 nanoribbons. Frequencies and linewidths of the Raman bands as a function of pressure also suggest a pressure-induced morphological change and the decreasing of the nanocrystal size. The observed spectroscopic changes are supported by electron microscopy images, which clearly show a pressure-induced morphologic change in MoO3 nanoribbons.

  5. Intermittent pressure decreases human keratinocyte proliferation in vitro.

    PubMed

    Nasca, Maria R; Shih, Alan T; West, Dennis P; Martinez, Wanda M; Micali, Giuseppe; Landsman, Adam S

    2007-01-01

    The aim of this study was to investigate the correlation between pressure changes and keratinocyte proliferation by determining whether keratinocytes exposed to altered mechanical pressures would proliferate at different rates compared to control cells not subjected to pressure changes. Tissue culture flasks of human keratinocytes plated at an approximate density of 15,000 cells/cm(2) undergoing an intermittent cyclic pressure of 362 mm Hg at a frequency of 2.28 or 5.16 cycles/min (0.038 or 0.086 Hz) for 8 h were compared to control flasks grown at ambient room pressure. An in-line pressure transducer was used to monitor and adjust pressure within the cell chambers, using a solenoid valve. A thymidine incorporation assay assessed the amount of cell proliferation in each set of experiments. Differences in proliferation between keratinocytes subjected to cyclic pressure changes and control cells were found to be statistically significant (p < 0.05) in 4 out of 5 proliferation assays. Also, a higher frequency of pressure changes consistently generated a reduced proliferation rate compared to that seen in cells exposed to a lower frequency of pressure changes. These data indicate that keratinocytes undergoing intermittent pressure changes exhibit decreased proliferation rates compared to controls. Furthermore, an increased frequency rate seems to have a greater effect on proliferation than low-frequency rate pressure changes, suggesting that the stress caused by frequently changed pressure may play a greater role in reducing keratinocyte proliferation than the actual magnitude of load applied to the cells. Our results support the current treatment protocol of reducing speed and duration of walking on the site of the wound to promote healing of foot ulcers. (c) 2007 S. Karger AG, Basel.

  6. Pressure-induced structural transition in chalcopyrite ZnSiP2

    NASA Astrophysics Data System (ADS)

    Bhadram, Venkata S.; Krishna, Lakshmi; Toberer, Eric S.; Hrubiak, Rostislav; Greenberg, Eran; Prakapenka, Vitali B.; Strobel, Timothy A.

    2017-05-01

    The pressure-dependent phase behavior of semiconducting chalcopyrite ZnSiP2 was studied up to 30 GPa using in situ X-ray diffraction and Raman spectroscopy in a diamond-anvil cell. A structural phase transition to the rock salt type structure was observed between 27 and 30 GPa, which is accompanied by soft phonon mode behavior and simultaneous loss of Raman signal and optical transmission through the sample. The high-pressure rock salt type phase possesses cationic disorder as evident from broad features in the X-ray diffraction patterns. The behavior of the low-frequency Raman modes during compression establishes a two-stage, order-disorder phase transition mechanism. The phase transition is partially reversible, and the parent chalcopyrite structure coexists with an amorphous phase upon slow decompression to ambient conditions.

  7. Comparative study between chemical and atmospheric pressure plasma jet cleaning on glass substrate

    NASA Astrophysics Data System (ADS)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Fhong, Soon Chin; Sahdan, Mohd Zainizan; Nayan, Nafarizal

    2017-01-01

    The atmospheric pressure plasma jet with low frequency and argon as working gas is presented in this paper to demonstrate its application for glass substrate clean and modification. The glass substrate clean by atmospheric pressure plasma jet is an efficient method to replace other substrate clean method. A comparative analysis is done in this paper between substrate cleaned by chemical and plasma treatment methods. Water contact angle reading is taken for a different method of substrate clean and period of treatment. Under the plasma treatment, the sample shows low surface adhesion due to having the surface property of super hydrophilic surface 7.26°. This comparative analysis is necessary in the industrial application for cost production due to sufficient time and method of substrate clean.

  8. Influence analysis of fluctuation parameters on flow stability based on uncertainty method

    NASA Astrophysics Data System (ADS)

    Meng, Tao; Fan, Shangchun; Wang, Chi; Shi, Huichao

    2018-05-01

    The relationship between flow fluctuation and pressure in a flow facility is studied theoretically and experimentally in this paper, and a method for measuring the flow fluctuation is proposed. According to the synchronicity of pressure and flow fluctuation, the amplitude of the flow fluctuation is calculated using the pressure measured in the flow facility and measurement of the flow fluctuation in a wide range of frequency is realized. Based on the method proposed, uncertainty analysis is used to evaluate the influences of different parameters on the flow fluctuation by the help of a sample-based stochastic model established and the parameters that have great influence are found, which can be a reference for the optimization design and the stability improvement of the flow facility.

  9. Effect of ultrasonic cavitation on measurement of sound pressure using hydrophone

    NASA Astrophysics Data System (ADS)

    Thanh Nguyen, Tam; Asakura, Yoshiyuki; Okada, Nagaya; Koda, Shinobu; Yasuda, Keiji

    2017-07-01

    Effect of ultrasonic cavitation on sound pressure at the fundamental, second harmonic, and first ultraharmonic frequencies was investigated from low to high ultrasonic intensities. The driving frequencies were 22, 304, and 488 kHz. Sound pressure was measured using a needle-type hydrophone and ultrasonic cavitation was estimated from the broadband integrated pressure (BIP). With increasing square root of electric power applied to a transducer, the sound pressure at the fundamental frequency linearly increased initially, dropped at approximately the electric power of cavitation inception, and afterward increased again. The sound pressure at the second harmonic frequency was detected just below the electric power of cavitation inception. The first ultraharmonic component appeared at around the electric power of cavitation inception at 304 and 488 kHz. However, at 22 kHz, the first ultraharmonic component appeared at a higher electric power than that of cavitation inception.

  10. Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.

    1990-01-01

    Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

  11. Analysis of automobile engine cylinder pressure and rotation speed from engine body vibration signal

    NASA Astrophysics Data System (ADS)

    Wang, Yuhua; Cheng, Xiang; Tan, Haishu

    2016-01-01

    In order to improve the engine vibration signal process method for the engine cylinder pressure and engine revolution speed measurement instrument, the engine cylinder pressure varying with the engine working cycle process has been regarded as the main exciting force for the engine block forced vibration. The forced vibration caused by the engine cylinder pressure presents as a low frequency waveform which varies with the cylinder pressure synchronously and steadily in time domain and presents as low frequency high energy discrete humorous spectrum lines in frequency domain. The engine cylinder pressure and the rotation speed can been extract form the measured engine block vibration signal by low-pass filtering analysis in time domain or by FFT analysis in frequency domain, the low-pass filtering analysis in time domain is not only suitable for the engine in uniform revolution condition but also suitable for the engine in uneven revolution condition. That provides a practical and convenient way to design motor revolution rate and cylinder pressure measurement instrument.

  12. Study of Stage-wise Pressure Pulsation in an Electric Submersible Pump under Variable Frequency Operation at Shut-off Condition

    NASA Astrophysics Data System (ADS)

    Dhanasekaran, A.; Kumaraswamy, S.

    2018-01-01

    Pressure pulsation causes vibration in the Electric Submersible Pump (ESP) and affects the life and performance of its system. ESP systems are installed at depths ranging from a few meters to several hundred meters. Unlike pumps used on the surface, once they are installed they become inaccessible for maintenance or for any kind of diagnostic measurement that might be taken directly on them. Therefore a detailed knowledge of mean and fluctuating pressures is required to achieve an optimal pressure distribution inside the ESP. This paper presents the results of an experimental investigation of the stage-wise pulsating pressure in ESP at shut-off condition at different speeds. Experiments were conducted on a pump having five stages. A variable frequency drive was used to operate the pump at five different speeds. Piezoresistive transducers were mounted at each stage of ESP to capture the unsteady pressure signals. Fast Fourier Transformation was carried out on the pressure signals to convert into frequency domain and the spectra of pressure pulsation signals were analyzed. The obtained results indicated the existence of fundamental frequency corresponding to the speed of rotation times the number of impeller blades and of the whole series of harmonics of higher frequencies.

  13. A numerical and experimental investigation on seismic anisotropy of Finero Peridotite, Ivrea-Verbano Zone, northern Italy

    NASA Astrophysics Data System (ADS)

    Zhong, Xin; Frehner, Marcel; Zappone, Alba; Kunze, Karsten

    2014-05-01

    We present a combined experimental and numerical study on Finero Peridotite to investigate the major factors creating its seismic anisotropy. We extrapolate the ultrasonic seismic wave velocity measured in a hydrostatic pressure vessel to 0 MPa and 250 MPa confining pressure to compare with numerical simulations at atmospheric pressure and to restore the velocity at in-situ lower crustal conditions, respectively. A linear relation between confining pressure and seismic velocity above 80 MPa reveals the intrinsic mechanical property of the bulk rock without the interference of cracks. To visualize the crystallographic preferred orientation (CPO) we use the electron backscatter diffraction (EBSD) method and create crystallographic orientation maps and pole figures. The first also reveals the shape preferred orientation (SPO). We found that very weak CPO but significant SPO exist in most of the peridotite. The Voigt and Reuss bounds as well as the Hill average (VRH) are calculated from EBSD data to visualize seismic velocity and to calculate anisotropy in the form of velocity pole figures. We perform finite element (FE) simulations of wave propagation on the EBSD crystallographic orientation maps to calculate the effective wave velocity at different propagation angles, hence estimate the anisotropy numerically. In fracture-free models the FE simulation results agree well with the Hill average. In one case of a sample containing fractures the FE simulation yields similar minimal velocity as the laboratory measurement, which lies outside the VR bounds. This is a warning that care has to be taken when using VRH averages in fractured rocks. All three velocity estimates (hydrostatic pressure vessel, VRH average, and FE simulation) result in equally weak seismic anisotropy. This is mainly the consequence of weak CPO. Although SPO is significantly stronger it has minor influence on anisotropy. Hydrous minerals influence the seismic anisotropy only when their modal composition is large enough to allow waves to propagate preferentially through them. Unlike hornblende, phlogopite is not proven to be a major source for the seismic anisotropy due to its small modal composition. Seismic velocity is also influenced by the source frequency distribution. A lower-frequency source in the FE simulations results in lower effective velocity regardless of sample orientation. The frequency spectrum of the propagating wave is modified from source to receiver due to scattering at the mineral grains, thus leading to effective negative attenuation factors peaked at around 1-3 MHz depending on the source spectrum. However, compared with other factors, such as CPO, SPO, fractures, or hydrous mineral phases, the effect of the source frequency distribution is minor, but may be influential when extrapolated to seismic frequencies (Hz-kHz). This study provides a comprehensive method combining laboratory measurements, EBSD data, and numerical simulations to estimate seismic anisotropy. Future work may focus on modeling the influence of different pore fluids or more complex fracture geometries on seismic velocity and anisotropy. Acknowledgements This work was supported by the Swiss National Science Foundation (project UPseis, 200021_143319).

  14. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    PubMed

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  15. Non-Newtonian fluid structure interaction in flexible biomimetic microchannels

    NASA Astrophysics Data System (ADS)

    Kiran, M.; Dasgupta, Sunando; Chakraborty, Suman

    2017-11-01

    To investigate the complex fluid structure interactions in a physiologically relevant microchannel with deformable wall and non-Newtonian fluid that flows within it, we fabricated cylindrical microchannels of various softness out of PDMS. Experiments to measure the transient pressure drop across the channel were carried out with high sampling frequencies to capture the intricate flow physics. In particular, we showed that the waveforms varies greatly for each of the non-Newtonian and Newtonian cases for both non-deformable and deformable microchannels in terms of the peak amplitude, r.m.s amplitude and the crest factor. In addition, we carried out frequency sweep experiments to evaluate the frequency response of the system. We believe that these results will aid in the design of polymer based microfluidic phantoms for arterial FSI studies, and in particular for studying blood analog fluids in cylindrical microchannels as well as developing frequency specific Lab-on-chip systems for medical diagnostics.

  16. Comparing otoacoustic emissions evoked by chirp transients with constant absorbed sound power and constant incident pressure magnitude

    PubMed Central

    Keefe, Douglas H.; Feeney, M. Patrick; Hunter, Lisa L.; Fitzpatrick, Denis F.

    2017-01-01

    Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz. PMID:28147608

  17. Effect of using a Planecta™ port with a three-way stopcock on the natural frequency of blood pressure transducer kits.

    PubMed

    Fujiwara, Shigeki; Tachihara, Keiichi; Mori, Satoshi; Ouchi, Kentaro; Yokoe, Chizuko; Imaizumi, Uno; Morimoto, Yoshinari; Miki, Yoichiro; Toyoguchi, Izumi; Yoshida, Kazu-Ichi; Yokoyama, Takeshi

    2016-12-01

    Blood pressure transducer kits are equipped with two types of Planecta™ ports-the flat-type Planecta™ port (FTP) and the Planecta™ port with a three-way stopcock (PTS). We reported that FTP application decreased the natural frequency of the kits. However, Planecta™ is an invaluable tool as it prevents infection, ensures technical simplicity, and excludes air. Hence, an ideal Planecta™ port that does not decrease the frequency characteristics is required. As a first step in this direction, we aimed to assess the influence of PTSs on the natural frequency of blood transducer kits. A DTXplus transducer kit (DT4812J; Argon Medical Devices, TX, USA) was used along with ≥1 PTSs (JMS, Hiroshima, Japan), and the frequency characteristics were assessed. The natural frequency and damping coefficient of each kit were obtained by using frequency characteristics analysis software, and these parameters were evaluated by plotting them on Gardner's chart. Regardless of whether one or two PTSs were inserted, the natural frequency of the kits only slightly decreased (from 42.5 to 41.1 Hz, when 2 PTSs were used). Thus, the frequency characteristics of the kits with PTSs were adequate for pressure monitoring. The insertion of ≥2 FTPs in pressure transducer kits should be avoided, as they markedly decrease the natural frequency and lead to underdamping. However, the effect of PTS insertion in pressure transducer kits on the frequency characteristics is minimal. Thus, we found that the use of PTS markedly improved the frequency characteristics as compared to the use of FTP.

  18. Acoustic emissions monitoring and synchrotron X-ray diffraction analysis of mineral dehydrations at high pressures and temperatures

    NASA Astrophysics Data System (ADS)

    Gasc, J.; Guillon, S.; Schubnel, A. J.; Brunet, F.; Lathe, C.; Mueller, H.

    2009-12-01

    We have monitored from in-situ X-ray diffraction coupled to Acoustic Emission (AE) imaging, the behavior of several materials under elevated pressures and temperatures (quartz, kaolinite, serpentinite). The samples were placed in a boron-epoxy assembly with an 8mm edge-length and loaded in the MAX80 cubic multi-anvil press installed on the German synchrotron (HASYLAB-DESY, Hamburg). AE were recorded using six piezoceramic transducers (2 MHz eigen frequency) glued on each of the six WC anvils. Full waveforms were acquired using an eight channel digital oscilloscope and a continuous acoustic recorder. Our system was first tested using quartz beads (500μm) aggregates. During cold compression performed on these samples many acoustic events were recorded and located inside the samples. These are obviously related to the fragile fracturing of the quartz due to the porosity loss. During the heating cycles performed on the same samples, the acoustic activity progressively vanishes between 300 and 400°C indicating the transition to the ductile regime towards higher temperatures. Further experiments were performed by mixing 20wt% of kaolinite to the quartz. As a result, the amount of acoustic emissions recorded during cold compression is significantly reduced. This is thought to be a result of the ductile behaviour of kaolinite even at low temperatures. This assumption has been confirmed by performing experiments on pure kaolinite which did not produce acoustic emissions during cold compression nor during heating cycles up to 1000°C (i.e. beyond the kaolinite dehydration temperature). This set of experiments clearly established that no acoustic activity is produced by the assembly and that AEs produced by the samples are accurately located by the software. The behaviour of serpentinite dehydration was then investigated under various pressure conditions (i.e. various volume changes), from ~0.6 to ~40kbars. These experiments were performed under deviatoric stress conditions by using Al2O3 waveguides. While clearly identified with the time resolved diffraction patterns, the dehydration process did not produce any AE, at least within the sensitivity and frequency ranges of our transducers. The microstructures observed on the recovered samples by SEM show features characteristic of fluid localisation and/or migration and highlight the fact that fractures were activated prior, during and after mineral dehydration. These results tend to show that the relationship between mineral dehydration, acoustic emission production, earthquakes and fracturing are not as straightforward as one could expect under high pressure and temperature conditions.

  19. Acoustic emissions monitoring and synchrotron X-ray diffraction analysis of mineral dehydrations at high pressures and temperatures

    NASA Astrophysics Data System (ADS)

    Schubnel, Alexandre; Julien, Gasc; Sophie, Guillon; Fabrice, Brunet; Christian, Lathe; Hans-Joachim, Mueller

    2010-05-01

    We have monitored from in-situ X-ray diffraction coupled to Acoustic Emission (AE) imaging, the behavior of several materials under elevated pressures and temperatures (quartz, kaolinite, serpentinite). The samples were placed in a boron-epoxy assembly with an 8mm edge-length and loaded in the MAX80 cubic multi-anvil press installed on the German synchrotron (HASYLAB-DESY, Hamburg). AE were recorded using six piezoceramic transducers (2 MHz eigen frequency) glued on each of the six WC anvils. Full waveforms were acquired using an eight channel digital oscilloscope and a continuous acoustic recorder. Our system was first tested using quartz beads (500μm) aggregates. During cold compression performed on these samples many acoustic events were recorded and located inside the samples. These are obviously related to the fragile fracturing of the quartz due to the porosity loss. During the heating cycles performed on the same samples, the acoustic activity progressively vanishes between 300 and 400°C indicating the transition to the ductile regime towards higher temperatures. Further experiments were performed by mixing 20wt% of kaolinite to the quartz. As a result, the amount of acoustic emissions recorded during cold compression is significantly reduced. This is thought to be a result of the ductile behaviour of kaolinite even at low temperatures. This assumption has been confirmed by performing experiments on pure kaolinite which did not produce acoustic emissions during cold compression nor during heating cycles up to 1000°C (i.e. beyond the kaolinite dehydration temperature). This set of experiments clearly established that no acoustic activity is produced by the assembly and that AEs produced by the samples are accurately located by the software. The behaviour of serpentinite dehydration was then investigated under various pressure conditions (i.e. various volume changes), from ~0.6 to ~40kbars. These experiments were performed under deviatoric stress conditions by using Al2O3 waveguides. While clearly identified with the time resolved diffraction patterns, the dehydration process did not produce any AE, at least within the sensitivity and frequency ranges of our transducers. The microstructures observed on the recovered samples by SEM show features characteristic of fluid localisation and/or migration and highlight the fact that fractures were activated prior, during and after mineral dehydration. These results tend to show that the relationship between mineral dehydration, acoustic emission production, earthquakes and fracturing are not as straightforward as one could expect under high pressure and temperature conditions.

  20. Optical pressure/density measuring means

    DOEpatents

    Veligdan, James T.

    1995-05-09

    An apparatus and method for rapidly and accurately determining the pressure of a fluid medium in either a static or dynamic state. The pressure is determined by making a measurement of the velocity of a light beam that is directed through the fluid medium along a pathway that enables an integrated pressure measurement to be made along the pathway, rather than making such a measurement only at a single point in the medium. A HeNe laser is configured to emit a beam of two frequencies separated by about 2 MHz. One of these beam frequencies is directed through the fluid medium and is reflected back through the medium to a non-linear diode detector. The other beam frequency is passed directly to a diode detector without traversing said medium. The diode detector is operated to determine the frequency shift or beat frequency between the two beam frequencies. Any variation in the frequency of said reflected beam that is caused by a change in its velocity as it is passed through the fluid medium causes a change in the beat frequency. This beat frequency change is then converted to an output signal value corresponding to the pressure of the medium. The measurement instrument apparatus is remotely positioned relative to the medium being measured, thus the apparatus is immune from electro-magnetic interference and can operate in conditions of high radiation, corrosion and extraordinarily high temperature.

  1. Optical pressure/density measuring means

    DOEpatents

    Veligdan, J.T.

    1995-05-09

    An apparatus and method are disclosed for rapidly and accurately determining the pressure of a fluid medium in either a static or dynamic state. The pressure is determined by making a measurement of the velocity of a light beam that is directed through the fluid medium along a pathway that enables an integrated pressure measurement to be made along the pathway, rather than making such a measurement only at a single point in the medium. A HeNe laser is configured to emit a beam of two frequencies separated by about 2 MHz. One of these beam frequencies is directed through the fluid medium and is reflected back through the medium to a non-linear diode detector. The other beam frequency is passed directly to a diode detector without traversing said medium. The diode detector is operated to determine the frequency shift or beat frequency between the two beam frequencies. Any variation in the frequency of said reflected beam that is caused by a change in its velocity as it is passed through the fluid medium causes a change in the beat frequency. This beat frequency change is then converted to an output signal value corresponding to the pressure of the medium. The measurement instrument apparatus is remotely positioned relative to the medium being measured, thus the apparatus is immune from electro-magnetic interference and can operate in conditions of high radiation, corrosion and extraordinarily high temperature. 4 figs.

  2. Investigation of an Axial Fan—Blade Stress and Vibration Due to Aerodynamic Pressure Field and Centrifugal Effects

    NASA Astrophysics Data System (ADS)

    Xu, Cheng; Amano, Ryoichi Samuel; Lee, Eng Kwong

    A 1.829m (6ft) diameter industrial large flow-rate axial fan operated at 1770rpm was studied experimentally in laboratory conditions. The flow characteristics on the fan blade surfaces were investigated by measuring the pressure distributions on the blade suction and pressure surfaces and the results were discussed by comparing with analytical formulations and CFD. Flow visualizations were also performed to validate the flow characteristics near the blade surface and it was demonstrated that the flow characteristics near the fan blade surface were dominated by the centrifugal force of the fan rotation which resulted in strong three-dimensional flows. The time-dependent pressure measurement showed that the pressure oscillations on the fan blade were significantly dominated by vortex shedding from the fan blades. It was further demonstrated that the pressure distributions during the fan start-up were highly unsteady, and the main frequency variation of the static pressure was much smaller than the fan rotational frequency. The time-dependent pressure measurement when the fan operated at a constant speed showed that the magnitude of the blade pressure variation with time and the main variation frequency was much smaller than the fan rotational frequency. The pressure variations that were related to the vortex shedding were slightly smaller than the fan rotational frequency. The strain gages were used to measure the blade stress and the results were compared with FEA results.

  3. Plasma surface cleaning in a microwave plasma source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, C.C.; Nelson, W.D.; Haselton, H.H.

    1994-03-01

    A microwave electron cyclotron resonance (ECR) plasma source has been operated to produce reactive plasmas of oxygen and its mixture with argon. Aluminum samples (0.95 cm by 1.9 cm) were coated with thin films (<20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in discharge conditions of microwave power up to 1300 W, radio frequency power up to 200 W, biased potential up to 400 V, gas pressures up to 5 mtorr, and operating time up to 35 min. The surface texture of the postcleaned samples has been examinedmore » visually. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured clean rates of low-pressure (0.5-mtorr) argon/oxygen plasmas were as high as 2.7 {mu}m/min. X-ray photoelectron spectroscopy (XPS) was used to determine cleanliness of the sample surfaces after plasma cleaning. The XPS study on polished samples confirmed the effectiveness of plasma cleaning in achieving atomic level of surface cleanliness. In this technical memorandum plasma properties, cleaning phenomena, and significant results are reported and discussed.« less

  4. An investigation into the effects of frequency-modulated transcutaneous electrical nerve stimulation (TENS) on experimentally-induced pressure pain in healthy human participants.

    PubMed

    Chen, Chih-Chung; Johnson, Mark I

    2009-10-01

    Frequency-modulated transcutaneous electrical nerve stimulation (TENS) delivers currents that fluctuate between preset boundaries over a fixed period of time. This study compared the effects of constant-frequency TENS and frequency-modulated TENS on blunt pressure pain in healthy human volunteers. Thirty-six participants received constant-frequency TENS (80 pps), frequency-modulated TENS (20 to 100 pps), and placebo (no current) TENS at a strong nonpainful intensity in a randomized cross-over manner. Pain threshold was taken from the forearm using pressure algometry. There were no statistical differences between constant-frequency TENS and frequency-modulated TENS after 20 minutes (OR = 1.54; CI, 0.29, 8.23, P = 1.0). Both constant-frequency TENS and frequency-modulated TENS were superior to placebo TENS (OR = 59.5, P < .001 and OR = 38.5, P < .001, respectively). Frequency-modulated TENS does not influence hypoalgesia to any greater extent than constant-frequency TENS when currents generate a strong nonpainful paraesthesia at the site of pain. The finding that frequency-modulated TENS and constant-frequency TENS were superior to placebo TENS provides further evidence that a strong yet nonpainful TENS intensity is a prerequisite for hypoalgesia. This study provides evidence that TENS, delivered at a strong nonpainful intensity, increases pain threshold to pressure algometry in healthy participants over and above that seen with placebo (no current) TENS. Frequency-modulated TENS does not increase hypoalgesia to any appreciable extent to that seen with constant-frequency TENS.

  5. Role of autonomic nervous activity, as measured by heart rate variability, on the effect of mortality in disabled older adults with low blood pressure in long-term care.

    PubMed

    Shibasaki, Koji; Ogawa, Sumito; Yamada, Shizuru; Ouchi, Yasuyoshi; Akishita, Masahiro

    2018-04-11

    Previous studies have shown the relationship between low blood pressure and high mortality in frail, disabled older adults in long-term care. However, the mechanism of this relationship is still unclear. We hypothesized that autonomic nervous activity decline is involved in the relationship between low blood pressure and high mortality. The present prospective cohort study recruited 61 participants aged ≥75 years. The data from 24-h Holter monitoring and blood pressure recorded by ambulatory blood pressure monitoring were collected. Measured data were divided into three categories: 24-h, daytime and night-time. From power spectral density in the electrocardiogram, low frequency, high frequency and low frequency/high frequency ratio were calculated. The primary end-point was death. High blood pressure was connected to both high daytime low frequency and high frequency (partial correlation coefficients: 0.42, P < 0.05 and 0.35, P < 0.05, respectively). In addition, the low blood pressure group had higher mortality than the high blood pressure group, and disabled older adults in long-term care and those with elevated daytime systolic and diastolic blood pressure had less risk of mortality compared with those without (systolic: hazard ratio 0.89, 95% confidence interval 0.83-0.96, P = 0.003; diastolic: hazard ratio 0.98, 95% confidence interval 0.79-1.00, P = 0.049). The average blood pressures in the high blood pressure groups were approximately 140/80 mmHg and were connected to low mortality. Attenuated autonomic nervous activity might lead to low blood pressure in the daytime and high mortality in disabled older adults in long-term care. Geriatr Gerontol Int 2018; ••: ••-••. © 2018 Japan Geriatrics Society.

  6. Pressure attenuation during high-frequency airway clearance therapy across different size endotracheal tubes: An in vitro study.

    PubMed

    Smallwood, Craig D; Bullock, Kevin J; Gouldstone, Andrew

    2016-08-01

    High-frequency airway clearance therapy is a positive pressure secretion clearance modality used in pediatric and adult applications. However, pressure attenuation across different size endotracheal tubes (ETT) has not been adequately described. This study quantifies attenuation in an in vitro model. The MetaNeb® System was used to deliver high-frequency pressure pulses to 3.0, 4.0, 6.0 and 8.0mm ID ETTs connected to a test lung during mechanical ventilation. The experimental setup included a 3D-printed trachea model and imbedded pressure sensors. The pressure attenuation (Patt%) was calculated: Patt%=[(Pproximal-Pdistal)/Pproximal]x100. The effect of pulse frequency on Pdistal and Pproximal was quantified. Patt% was inversely and linearly related to ETT ID and (y=-7.924x+74.36; R(2)=0.9917, P=.0042 for 4.0Hz pulse frequency and y=-7.382+9.445, R(2)=0.9964, P=.0018 for 3.0Hz pulse frequency). Patt% across the 3.0, 4.0, 6.0 and 8.0mm I.D. ETTs was 48.88±10.25%, 40.87±5.22%, 27.97±5.29%, and 9.90±1.9% respectively. Selecting the 4.0Hz frequency mode demonstrated higher Pproximal and Pdistal compared to the 3.0Hz frequency mode (P=.0049 and P=.0065). Observed Pdistal was <30cmH2O for all experiments. In an in vitro model, pressure attenuation was linearly related to the inner diameter of the endotracheal tube; with decreasing attenuation as the ETT size increased. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Hugoniot-measurements of room- and high-temperature metals for study of EOS and strength

    NASA Astrophysics Data System (ADS)

    Mashimo, Tsutomu; Gomoto, Yuya; Takashima, Hideyuki; Murai, Mitsuru; Yoshiasa, Akira

    2011-06-01

    Pressure calibration in static high-pressure experiments has been undertaken on the basis of the EOS derived from the Hugoniot compression curves of metals (Au, Pt, Cu, W, etc.), MgO, etc. To obtain the strict EOS at room- and high-temperatures, we need to precisely measure the Hugoniot data, and access the strength and Grüneisen parameter under shock compression. If the Hugoniot data of elevated temperature samples are measured, the high-temperature EOS can be accurately derived, and the Grüneisen parameter can be directly discussed. The strength might decrease at high temperature. The Hugoniot-measurement experiments have been performed on single crystal Au, oxygen-free Cu, forged Ta and W by a streak photographic system equipped with a powder gun and two-stage light gas gun in the pressure range up to >200 GPa. In addition, the Hugoniot-measurement experiment of the elevated temperature samples was started using high-frequency heating on W, Au, etc. Some of the results will be presented, and the EOS and strength are discussed.

  8. Sound Pressure Level Gain in an Acoustic Metamaterial Cavity

    PubMed Central

    Song, Kyungjun; Kim, Kiwon; Hur, Shin; Kwak, Jun-Hyuk; Park, Jihyun; Yoon, Jong Rak; Kim, Jedo

    2014-01-01

    The inherent attenuation of a homogeneous viscous medium limits radiation propagation, thereby restricting the use of many high-frequency acoustic devices to only short-range applications. Here, we design and experimentally demonstrate an acoustic metamaterial localization cavity which is used for sound pressure level (SPL) gain using double coiled up space like structures thereby increasing the range of detection. This unique behavior occurs within a subwavelength cavity that is 1/10th of the wavelength of the incident acoustic wave, which provides up to a 13 dB SPL gain. We show that the amplification results from the Fabry-Perot resonance of the cavity, which has a simultaneously high effective refractive index and effective impedance. We also experimentally verify the SPL amplification in an underwater environment at higher frequencies using a sample with an identical unit cell size. The versatile scalability of the design shows promising applications in many areas, especially in acoustic imaging and underwater communication. PMID:25502279

  9. Individual Monitoring of Vocal Effort With Relative Fundamental Frequency: Relationships With Aerodynamics and Listener Perception.

    PubMed

    Lien, Yu-An S; Michener, Carolyn M; Eadie, Tanya L; Stepp, Cara E

    2015-06-01

    The acoustic measure relative fundamental frequency (RFF) was investigated as a potential objective measure to track variations in vocal effort within and across individuals. Twelve speakers with healthy voices created purposeful modulations in their vocal effort during speech tasks. RFF and an aerodynamic measure of vocal effort, the ratio of sound pressure level to subglottal pressure level, were estimated from the aerodynamic and acoustic signals. Twelve listeners also judged the speech samples for vocal effort using the visual sort and rate method. Relationships between RFF and both the aerodynamic and perceptual measures of vocal effort were weak across speakers (R2 = .06-.26). Within speakers, relationships were variable but much stronger on average (R2 = .45-.56). RFF showed stronger relationships between both the aerodynamic and perceptual measures of vocal effort when examined within individuals versus across individuals. Future work is necessary to establish these relationships in individuals with voice disorders across the therapeutic process.

  10. Design and Implementation of a new Autonomous Sensor Fish to Support Advanced Hydropower Development

    DOE PAGES

    Deng, Zhiqun; Lu, Jun; Myjak, Mitchell J.; ...

    2014-11-04

    Acceleration in development of additional conventional hydropower requires tools and methods to perform laboratory and in-field validation of turbine performance and fish passage claims. The new-generation Sensor Fish has been developed with more capabilities to accommodate a wider range of users over a wider range of turbine designs and operating environments. It provides in situ measurements of three dimensional (3D) accelerations, 3D rotational velocities, 3D orientation, pressure, and temperature at a sampling frequency of 2048 Hz. It also has an automatic floatation system and built-in radio frequency transmitter for recovery. The relative errors of the pressure, acceleration and rotational velocitymore » were within ±2%, ±5%, and ±5%, respectively. The accuracy of orientation was within ±4° and accuracy of temperature was ±2°C. It is being deployed to evaluate the biological effects of turbines or other hydraulic structures in several countries.« less

  11. Individual Monitoring of Vocal Effort With Relative Fundamental Frequency: Relationships With Aerodynamics and Listener Perception

    PubMed Central

    Michener, Carolyn M.; Eadie, Tanya L.; Stepp, Cara E.

    2015-01-01

    Purpose The acoustic measure relative fundamental frequency (RFF) was investigated as a potential objective measure to track variations in vocal effort within and across individuals. Method Twelve speakers with healthy voices created purposeful modulations in their vocal effort during speech tasks. RFF and an aerodynamic measure of vocal effort, the ratio of sound pressure level to subglottal pressure level, were estimated from the aerodynamic and acoustic signals. Twelve listeners also judged the speech samples for vocal effort using the visual sort and rate method. Results Relationships between RFF and both the aerodynamic and perceptual measures of vocal effort were weak across speakers (R2 = .06–.26). Within speakers, relationships were variable but much stronger on average (R2 = .45–.56). Conclusions RFF showed stronger relationships between both the aerodynamic and perceptual measures of vocal effort when examined within individuals versus across individuals. Future work is necessary to establish these relationships in individuals with voice disorders across the therapeutic process. PMID:25675090

  12. Pressure effect on phonon frequencies in some transition metals: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Kazanc, S.; Ozgen, S.

    2005-08-01

    It is important to determine the atomic lattice vibrations of metallic materials, under high-pressure conditions, due to its effects on material properties such as thermal, electrical and optical conductions. In this work, we have investigated the changes of acoustic phonon frequencies with hydrostatic pressure for Cu, Ni, Al, Ag and Au transition metals, using molecular dynamics (MD) simulations based on embedded atom method (EAM). For this aim, we have adopted the embedded atom potential proposed by Sutton and Chen. The phonon frequencies have been calculated from the dynamical matrix for [1 0 0], [1 1 0] and [1 1 1] high symmetry directions of the Brillouin zone. The obtained results show that the hydrostatic pressure causes an increment in phonon frequencies, and this rising do not depend linearly on the increasing pressure.

  13. Method and Apparatus for Measuring Surface Air Pressure

    NASA Technical Reports Server (NTRS)

    Lin, Bing (Inventor); Hu, Yongxiang (Inventor)

    2014-01-01

    The present invention is directed to an apparatus and method for remotely measuring surface air pressure. In one embodiment, the method of the present invention utilizes the steps of transmitting a signal having multiple frequencies into the atmosphere, measuring the transmitted/reflected signal to determine the relative received power level of each frequency and then determining the surface air pressure based upon the attenuation of the transmitted frequencies.

  14. Non-Intrusive Pressure/Multipurpose Sensor and Method

    NASA Technical Reports Server (NTRS)

    Smith, William C. (Inventor)

    2001-01-01

    Method and apparatus are provided for determining pressure using a non-intrusive sensor that is easily attachable to the plumbing of a pressurized system. A bent mode implementation and a hoop mode implementation of the invention are disclosed. Each of these implementations is able to nonintrusively measure pressure while fluid is flowing. As well, each implementation may be used to measure mass flow rate simultaneously with pressure. An ultra low noise control system is provided for making pressure measurements during gas flow. The control system includes two tunable digital bandpass filters with center frequencies that are responsive to a clock frequency. The clock frequency is divided by a factor of N to produce a driving vibrational signal for resonating a metal sensor section.

  15. Effects of large pressure amplitude low frequency noise in the parotid gland perivasculo-ductal connective tissue.

    PubMed

    Oliveira, Pedro; Brito, José; Mendes, João; da Fonseca, Jorge; Águas, Artur; Martins dos Santos, José

    2013-01-01

    In tissues and organs exposed to large pressure amplitude low frequency noise fibrosis occurs in the absence of inflammatory signs, which is thought to be a protective response. In the parotid gland the perivasculo-ductal connective tissue surrounds arteries, veins and the ductal tree. Perivasculo-ductal connective tissue is believed to function as a mechanical stabilizer of the glandular tissue. In order to quantify the proliferation of perivasculo-ductal connective tissue in large pressure amplitude low frequency noise-exposed rats we used sixty Wistar rats which were equally divided into 6 groups. One group kept in silence, and the remaining five exposed to continuous large pressure amplitude low frequency noise: g1-168h (1 week); g2-504h (3 weeks); g3-840h (5 weeks); g4-1512h (9 weeks); and g5-2184h (13 weeks). After exposure, parotid glands were removed and the perivasculo-ductal connective tissue area was measured in all groups. We applied ANOVA statistical analysis, using SPSS 13.0. The global trend is an increase in the average perivasculo-ductal connective tissue areas, that develops linearly and significantly with large pressure amplitude low frequency noise exposure time (p < 0.001). It has been suggested that the biological response to large pressure amplitude low frequency noise exposure is associated with the need to maintain structural integrity. The structural reinforcement would be achieved by increased perivasculo-ductal connective tissue. Hence, these results show that in response to large pressure amplitude low frequency noise exposure, rat parotid glands increase their perivasculo-ductal connective tissue.

  16. High-sensitivity NMR beyond 200,000 atmospheres of pressure.

    PubMed

    Meier, T; Reichardt, S; Haase, J

    2015-08-01

    Pressure-induced changes in the chemical or electronic structure of solids require pressures well into the Giga-Pascal (GPa) range due to the strong bonding. Anvil cell designs can reach such pressures, but their small and mostly inaccessible sample chamber has severely hampered NMR experiments in the past. With a new cell design that has a radio frequency (RF) micro-coil in the high pressure chamber, NMR experiments beyond 20 Giga-Pascal are reported for the first time. (1)H NMR of water shows sensitivity and resolution obtained with the cells, and (63)Cu NMR on a cuprate superconductor (YBa2Cu3O7-δ) demonstrates that single-crystals can be investigated, as well. (115)In NMR of the ternary chalcogenide AgInTe2 discovers an insulator-metal transition with shift and relaxation measurements. The pressure cells can be mounted easily on standard NMR probes that fit commercial wide-bore magnets with regular cryostats for field- and temperature-dependent measurements ready for many applications in physics and chemistry. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Extreme pressure differences at 0900 NZST and winds across New Zealand

    NASA Astrophysics Data System (ADS)

    Salinger, M. James; Griffiths, Georgina M.; Gosai, Ashmita

    2005-07-01

    Trends in extremes in station daily sea-level pressure differences at 0900 NZST are examined, and extreme daily wind gusts, across New Zealand, since the 1960s. Annual time series were examined (with indices of magnitude and frequency over threshold percentiles) from the daily indices selected. These follow from earlier indices of normalized monthly mean sea-level pressure differences between station pairs, except the daily indices are not normalized. The frequency statistics quantify the number of extreme zonal (westerly and easterly), or extreme meridional (southerly or northerly), pressure gradient events. The frequency and magnitude of extreme westerly episodes has increased slightly over New Zealand, with a significant increase in the westerly extremes to the south of New Zealand. In contrast, the magnitude and frequency of easterly extremes has decreased over New Zealand, but increased to the south, with some trends weakly significant. The frequency and magnitude of daily southerly extremes has decreased significantly in the region.Extreme daily wind gust events at key climate stations in New Zealand and at Hobart, Australia, are highly likely to be associated with an extreme daily pressure difference. The converse was less likely to hold: extreme wind gusts were not always observed on days with extreme daily pressure difference, probably due to the strong influence that topography has on localized station winds. Significant correlations exist between the frequency indices and both annual-average mean sea-level pressures around the Australasian region and annual-average sea surface temperature (SST) anomalies in the Southern Hemisphere. These correlations are generally stronger for indices of extreme westerly or extreme southerly airflows. Annual-average pressures in the Tasman Sea or Southern Ocean are highly correlated to zonal indices (frequency of extreme westerlies). SST anomalies in the NINO3 region or on either side of the South Island are significantly correlated with the frequency of extreme westerly airflows.

  18. Pressurized transient otoacoustic emissions measured using click and chirp stimuli.

    PubMed

    Keefe, Douglas H; Patrick Feeney, M; Hunter, Lisa L; Fitzpatrick, Denis F; Sanford, Chris A

    2018-01-01

    Transient-evoked otoacoustic emission (TEOAE) responses were measured in normal-hearing adult ears over frequencies from 0.7 to 8 kHz, and analyzed with reflectance/admittance data to measure absorbed sound power and the tympanometric peak pressure (TPP). The mean TPP was close to ambient. TEOAEs were measured in the ear canal at ambient pressure, TPP, and fixed air pressures from 150 to -200 daPa. Both click and chirp stimuli were used to elicit TEOAEs, in which the incident sound pressure level was constant across frequency. TEOAE levels were similar at ambient and TPP, and for frequencies from 0.7 to 2.8 kHz decreased with increasing positive and negative pressures. At 4-8 kHz, TEOAE levels were larger at positive pressures. This asymmetry is possibly related to changes in mechanical transmission through the ossicular chain. The mean TEOAE group delay did not change with pressure, although small changes were observed in the mean instantaneous frequency and group spread. Chirp TEOAEs measured in an adult ear with Eustachian tube dysfunction and TPP of -165 daPa were more robust at TPP than at ambient. Overall, results demonstrate the feasibility and clinical potential of measuring TEOAEs at fixed pressures in the ear canal, which provide additional information relative to TEOAEs measured at ambient pressure.

  19. Do pressures to publish increase scientists' bias? An empirical support from US States Data.

    PubMed

    Fanelli, Daniele

    2010-04-21

    The growing competition and "publish or perish" culture in academia might conflict with the objectivity and integrity of research, because it forces scientists to produce "publishable" results at all costs. Papers are less likely to be published and to be cited if they report "negative" results (results that fail to support the tested hypothesis). Therefore, if publication pressures increase scientific bias, the frequency of "positive" results in the literature should be higher in the more competitive and "productive" academic environments. This study verified this hypothesis by measuring the frequency of positive results in a large random sample of papers with a corresponding author based in the US. Across all disciplines, papers were more likely to support a tested hypothesis if their corresponding authors were working in states that, according to NSF data, produced more academic papers per capita. The size of this effect increased when controlling for state's per capita R&D expenditure and for study characteristics that previous research showed to correlate with the frequency of positive results, including discipline and methodology. Although the confounding effect of institutions' prestige could not be excluded (researchers in the more productive universities could be the most clever and successful in their experiments), these results support the hypothesis that competitive academic environments increase not only scientists' productivity but also their bias. The same phenomenon might be observed in other countries where academic competition and pressures to publish are high.

  20. Development of multi-frequency ESR system for high-pressure measurements up to 2.5 GPa

    NASA Astrophysics Data System (ADS)

    Sakurai, T.; Fujimoto, K.; Matsui, R.; Kawasaki, K.; Okubo, S.; Ohta, H.; Matsubayashi, K.; Uwatoko, Y.; Tanaka, H.

    2015-10-01

    A new piston-cylinder pressure cell for electron spin resonance (ESR) has been developed. The pressure cell consists of a double-layer hybrid-type cylinder with internal components made of the ZrO2-based ceramics. It can generate a pressure of 2 GPa repeatedly and reaches a maximum pressure of around 2.5 GPa. A high-pressure ESR system using a cryogen-free superconducting magnet up 10 T has also been developed for this hybrid-type pressure cell. The frequency region is from 50 GHz to 400 GHz. This is the first time a pressure above 2 GPa has been achieved in multi-frequency ESR system using a piston-cylinder pressure cell. We demonstrate its potential by showing the results of the high-pressure ESR of the S = 1 system with the single ion anisotropy NiSnCl6 · 6H2O and the S = 1 / 2 quantum spin system CsCuCl3. We performed ESR measurements of these systems above 2 GPa successfully.

  1. Laboratory triggering of stick-slip events by oscillatory loading in the presence of pore fluid with implications for physics of tectonic tremor

    USGS Publications Warehouse

    Bartlow, Noel M.; Lockner, David A.; Beeler, Nicholas M.

    2012-01-01

    The physical mechanism by which the low-frequency earthquakes (LFEs) that make up portions of tectonic (also called non-volcanic) tremor are created is poorly understood. In many areas of the world, tectonic tremor and LFEs appear to be strongly tidally modulated, whereas ordinary earthquakes are not. Anomalous seismic wave speeds, interpreted as high pore fluid pressure, have been observed in regions that generate tremor. Here we build upon previous laboratory studies that investigated the response of stick-slip on artificial faults to oscillatory, tide-like loading. These previous experiments were carried out using room-dry samples of Westerly granite, at one effective stress. Here we augment these results with new experiments on Westerly granite, with the addition of varying effective stress using pore fluid at two pressures. We find that raising pore pressure, thereby lowering effective stress can significantly increase the degree of correlation of stick-slip to oscillatory loading. We also find other pore fluid effects that become important at higher frequencies, when the period of oscillation is comparable to the diffusion time of pore fluid into the fault. These results help constrain the conditions at depth that give rise to tidally modulated LFEs, providing confirmation of the effective pressure law for triggering and insights into why tremor is tidally modulated while earthquakes are at best only weakly modulated.

  2. Doppler Broadening Thermometry Based on Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Wang, Jin; Sun, Yu Robert; Cheng, Cunfeng; Tao, Lei-Gang; Tan, Yan; Kang, Peng; Liu, An-Wen; Hu, Shui-Ming

    2016-06-01

    A Doppler broadening thermometry (DBT) instrument is implemented based on a laser-locked cavity ring-down spectrometer. [1,2] It can be used to determine the Boltzmann constant by measuring the Doppler width of a molecular ro-vibrational transition in the near infrared. Compared with conventional direct absorption methods, the high-sensitivity of CRDS allows to reach satisfied precision at lower sample pressures, which reduces the influence due to collisions. By measuring the ro-vibrational transition of C_2H_2 at 787 nm, we demonstrate a statistical uncertainty of 6 ppm (part per million) in the determined linewidth by several hours' measurement at a sample pressure of 1.5 Pa. [3] However, the complicity in the spectrum of a polyatomic molecule induces potential systematic influence on the line profile due to nearby ``hidden'' lines from weak bands or minor isotopologues. Recently, the instrument has been upgraded in both sensitivity and frequency accuracy. A narrow-band fiber laser frequency-locked to a frequency comb is applied, and overtone transitions at 1.56 μm of the 12C16O molecule are used in the CRDS-DBT measurements. The simplicity of the spectrum of the diatomic CO molecule eliminates the potential influence from ``hidden'' lines. Our preliminary measurements and analysis show that it is feasible to pursue a DBT measurement toward the 1 ppm precision. H. Pan, et al., Rev. Sci. Instrum. 82, 103110 (2011) Y. R. Sun, et al., Opt. Expr., 19, 19993 (2011) C.-F. Cheng, et al., Metrologia, 52, S385 (2015)

  3. A program to evaluate a control system based on feedback of aerodynamic pressure differentials

    NASA Technical Reports Server (NTRS)

    Levy, D. W.; Finn, P.; Roskam, J.

    1981-01-01

    The use of aerodynamic pressure differentials to position a control surface is evaluated. The system is a differential pressure command loop, analogous to a position command loop, where the surface is commanded to move until a desired differential pressure across the surface is achieved. This type of control is more direct and accurate because it is the differential pressure which causes the control forces and moments. A frequency response test was performed in a low speed wind tunnel to measure the performance of the system. Both pressure and position feedback were tested. The pressure feedback performed as well as position feedback implying that the actuator, with a break frequency on the order of 10 Rad/sec, was the limiting component. Theoretical considerations indicate that aerodynamic lags will not appear below frequencies of 50 Rad/sec, or higher.

  4. Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations

    NASA Technical Reports Server (NTRS)

    Koh, J.; Brown, T. E.; Beightol, L. A.; Eckberg, D. L.

    1998-01-01

    We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.

  5. Effect of chemical composition on the electrical conductivity of gneiss at high temperatures and pressures

    NASA Astrophysics Data System (ADS)

    Dai, Lidong; Sun, Wenqing; Li, Heping; Hu, Haiying; Wu, Lei; Jiang, Jianjun

    2018-03-01

    The electrical conductivity of gneiss samples with different chemical compositions (WA = Na2O + K2O + CaO = 7.12, 7.27 and 7.64 % weight percent) was measured using a complex impedance spectroscopic technique at 623-1073 K and 1.5 GPa and a frequency range of 10-1 to 106 Hz. Simultaneously, a pressure effect on the electrical conductivity was also determined for the WA = 7.12 % gneiss. The results indicated that the gneiss conductivities markedly increase with total alkali and calcium ion content. The sample conductivity and temperature conform to an Arrhenius relationship within a certain temperature range. The influence of pressure on gneiss conductivity is weaker than temperature, although conductivity still increases with pressure. According to various ranges of activation enthalpy (0.35-0.52 and 0.76-0.87 eV) at 1.5 GPa, two main conduction mechanisms are suggested that dominate the electrical conductivity of gneiss: impurity conduction in the lower-temperature region and ionic conduction (charge carriers are K+, Na+ and Ca2+) in the higher-temperature region. The electrical conductivity of gneiss with various chemical compositions cannot be used to interpret the high conductivity anomalies in the Dabie-Sulu ultrahigh-pressure metamorphic belt. However, the conductivity-depth profiles for gneiss may provide an important constraint on the interpretation of field magnetotelluric conductivity results in the regional metamorphic belt.

  6. Contribution of autonomic dysfunction to abnormal exercise blood pressure in type 2 diabetes mellitus.

    PubMed

    Weston, Kassia S; Sacre, Julian W; Jellis, Christine L; Coombes, Jeff S

    2013-01-01

    The purpose of this study was to compare the presence and severity of autonomic dysfunction in type 2 diabetes mellitus patients, with and without exaggerated blood pressure responses to exercise. We performed a cross-sectional analysis of 98 patients with type 2 diabetes mellitus (aged 59±9). Both time (standard deviation of RR intervals, root-mean-square of successive RR interval differences) and frequency (total spectral power, high frequency, low frequency, very low frequency) domains of heart rate variability were analysed in a 5 min recording at rest and 20 min after a maximal treadmill test. An exaggerated blood pressure response to exercise was identified by peak blood pressure ≥190/105 mmHg (women) or ≥210/105 mmHg (men). Each group of either exaggerated exercise blood pressure response or normal blood pressure response consisted of 49 patients. At rest there were no significant differences between groups for all time and frequency domain parameters of heart rate variability. Post-exercise, there was a significant (p<0.05) reduction in the SDNN, RMSSD and TP in the exaggerated exercise blood pressure group. Independent correlates (p<0.01) of exercise systolic blood pressure included post-exercise TP, resting systolic blood pressure, cardiac autonomic neuropathy and beta-blockers (beta=-0.28, adj. R² = 0.32, p<0.001). Reduced post-exercise heart rate variability in patients with type 2 diabetes mellitus, with an exaggerated exercise blood pressure response suggests preclinical autonomic dysfunction characterized by impaired vagal modulation. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Dynamic pressure sensitivity determination with Mach number method

    NASA Astrophysics Data System (ADS)

    Sarraf, Christophe; Damion, Jean-Pierre

    2018-05-01

    Measurements of pressure in fast transient conditions are often performed even if the dynamic characteristic of the transducer are not traceable to international standards. Moreover, the question of a primary standard in dynamic pressure is still open, especially for gaseous applications. The question is to improve dynamic standards in order to respond to expressed industrial needs. In this paper, the method proposed in the EMRP IND09 ‘Dynamic’ project, which can be called the ‘ideal shock tube method’, is compared with the ‘collective standard method’ currently used in the Laboratoire de Métrologie Dynamique (LNE/ENSAM). The input is a step of pressure generated by a shock tube. The transducer is a piezoelectric pressure sensor. With the ‘ideal shock tube method’ the sensitivity of a pressure sensor is first determined dynamically. This method requires a shock tube implemented with piezoelectric shock wave detectors. The measurement of the Mach number in the tube allows an evaluation of the incident pressure amplitude of a step using a theoretical 1D model of the shock tube. Heat transfer, other actual effects and effects of the shock tube imperfections are not taken into account. The amplitude of the pressure step is then used to determine the sensitivity in dynamic conditions. The second method uses a frequency bandwidth comparison to determine pressure at frequencies from quasi-static conditions, traceable to static pressure standards, to higher frequencies (up to 10 kHz). The measurand is also a step of pressure generated by a supposed ideal shock tube or a fast-opening device. The results are provided as a transfer function with an uncertainty budget assigned to a frequency range, also deliverable frequency by frequency. The largest uncertainty in the bandwidth of comparison is used to trace the final pressure step level measured in dynamic conditions, owing that this pressure is not measurable in a steady state on a shock tube. A reference sensor thereby calibrated can be used in a comparison measurement process. At high frequencies the most important component of the uncertainty in this method is due to actual shock tube complex effects not already functionalized nowadays or thought not to be functionalized in this kind of direct method. After a brief review of both methods and a brief review of the determination of the transfer function of pressure transducers, and the budget of associated uncertainty for the dynamic calibration of a pressure transducer in gas, this paper presents a comparison of the results obtained with the ‘ideal shock tube’ and the ‘collective standard’ methods.

  8. Ultrasonic speech translator and communications system

    DOEpatents

    Akerman, M.A.; Ayers, C.W.; Haynes, H.D.

    1996-07-23

    A wireless communication system undetectable by radio frequency methods for converting audio signals, including human voice, to electronic signals in the ultrasonic frequency range, transmitting the ultrasonic signal by way of acoustical pressure waves across a carrier medium, including gases, liquids, or solids, and reconverting the ultrasonic acoustical pressure waves back to the original audio signal. The ultrasonic speech translator and communication system includes an ultrasonic transmitting device and an ultrasonic receiving device. The ultrasonic transmitting device accepts as input an audio signal such as human voice input from a microphone or tape deck. The ultrasonic transmitting device frequency modulates an ultrasonic carrier signal with the audio signal producing a frequency modulated ultrasonic carrier signal, which is transmitted via acoustical pressure waves across a carrier medium such as gases, liquids or solids. The ultrasonic receiving device converts the frequency modulated ultrasonic acoustical pressure waves to a frequency modulated electronic signal, demodulates the audio signal from the ultrasonic carrier signal, and conditions the demodulated audio signal to reproduce the original audio signal at its output. 7 figs.

  9. Pressure-induced structural transition in chalcopyrite ZnSiP 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhadram, Venkata S.; Krishna, Lakshmi; Toberer, Eric S.

    The pressure-dependent phase behavior of semiconducting chalcopyrite ZnSiP 2 was studied up to 30 GPa using in situ X-ray diffraction and Raman spectroscopy in a diamond-anvil cell. A structural phase transition to the rock salt type structure was observed between 27 and 30 GPa, which is accompanied by soft phonon mode behavior and simultaneous loss of Raman signal and optical transmission through the sample. The high-pressure rock salt type phase possesses cationic disorder as evident from broad features in the X-ray diffraction patterns. The behavior of the low-frequency Raman modes during compression establishes a two-stage, order-disorder phase transition mechanism. Themore » phase transition is partially reversible, and the parent chalcopyrite structure coexists with an amorphous phase upon slow decompression to ambient conditions.« less

  10. Measured wavenumber: frequency spectrum associated with acoustic and aerodynamic wall pressure fluctuations.

    PubMed

    Arguillat, Blandine; Ricot, Denis; Bailly, Christophe; Robert, Gilles

    2010-10-01

    Direct measurements of the wavenumber-frequency spectrum of wall pressure fluctuations beneath a turbulent plane channel flow have been performed in an anechoic wind tunnel. A rotative array has been designed that allows the measurement of a complete map, 63×63 measuring points, of cross-power spectral densities over a large area. An original post-processing has been developed to separate the acoustic and the aerodynamic exciting loadings by transforming space-frequency data into wavenumber-frequency spectra. The acoustic part has also been estimated from a simple Corcos-like model including the contribution of a diffuse sound field. The measured acoustic contribution to the surface pressure fluctuations is 5% of the measured aerodynamic surface pressure fluctuations for a velocity and boundary layer thickness relevant for automotive interior noise applications. This shows that for aerodynamically induced car interior noise, both contributions to the surface pressure fluctuations on car windows have to be taken into account.

  11. A correlational analysis of the effects of changing environmental conditions on the NR atomic hydrogen maser

    NASA Technical Reports Server (NTRS)

    Dragonette, Richard A.; Suter, Joseph J.

    1992-01-01

    An extensive statistical analysis has been undertaken to determine if a correlation exists between changes in an NR atomic hydrogen maser's frequency offset and changes in environmental conditions. Correlation analyses have been performed comparing barometric pressure, humidity, and temperature with maser frequency offset as a function of time for periods ranging from 5.5 to 17 days. Semipartial correlation coefficients as large as -0.9 have been found between barometric pressure and maser frequency offset. Correlation between maser frequency offset and humidity was small compared to barometric pressure and unpredictable. Analysis of temperature data indicates that in the most current design, temperature does not significantly affect maser frequency offset.

  12. The frequency dependence of the discharge properties in a capacitively coupled oxygen discharge

    NASA Astrophysics Data System (ADS)

    Gudmundsson, J. T.; Snorrason, D. I.; Hannesdottir, H.

    2018-02-01

    We use the one-dimensional object-oriented particle-in-cell Monte Carlo collision code oopd1 to explore the evolution of the charged particle density profiles, electron heating mechanism, the electron energy probability function (EEPF), and the ion energy distribution in a single frequency capacitively coupled oxygen discharge, with driving frequency in the range 12-100 MHz. At a low driving frequency and low pressure (5 and 10 mTorr), a combination of stochastic (α-mode) and drift ambipolar (DA) heating in the bulk plasma (the electronegative core) is observed and the DA-mode dominates the time averaged electron heating. As the driving frequency or pressure are increased, the heating mode transitions into a pure α-mode, where electron heating in the sheath region dominates. At low pressure (5 and 10 mTorr), this transition coincides with a sharp decrease in electronegativity. At low pressure and low driving frequency, the EEPF is concave. As the driving frequency is increased, the number of low energy electrons increases and the relative number of higher energy electrons (>10 eV) increases. At high driving frequency, the EEPF develops a convex shape or becomes bi-Maxwellian.

  13. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    NASA Technical Reports Server (NTRS)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  14. Subglottal pressure, tracheal airflow, and intrinsic laryngeal muscle activity during rat ultrasound vocalization

    PubMed Central

    2011-01-01

    Vocal production requires complex planning and coordination of respiratory, laryngeal, and vocal tract movements, which are incompletely understood in most mammals. Rats produce a variety of whistles in the ultrasonic range that are of communicative relevance and of importance as a model system, but the sources of acoustic variability were mostly unknown. The goal was to identify sources of fundamental frequency variability. Subglottal pressure, tracheal airflow, and electromyographic (EMG) data from two intrinsic laryngeal muscles were measured during 22-kHz and 50-kHz call production in awake, spontaneously behaving adult male rats. During ultrasound vocalization, subglottal pressure ranged between 0.8 and 1.9 kPa. Pressure differences between call types were not significant. The relation between fundamental frequency and subglottal pressure within call types was inconsistent. Experimental manipulations of subglottal pressure had only small effects on fundamental frequency. Tracheal airflow patterns were also inconsistently associated with frequency. Pressure and flow seem to play a small role in regulation of fundamental frequency. Muscle activity, however, is precisely regulated and very sensitive to alterations, presumably because of effects on resonance properties in the vocal tract. EMG activity of cricothyroid and thyroarytenoid muscle was tonic in calls with slow or no fundamental frequency modulations, like 22-kHz and flat 50-kHz calls. Both muscles showed brief high-amplitude, alternating bursts at rates up to 150 Hz during production of frequency-modulated 50-kHz calls. A differentiated and fine regulation of intrinsic laryngeal muscles is critical for normal ultrasound vocalization. Many features of the laryngeal muscle activation pattern during ultrasound vocalization in rats are shared with other mammals. PMID:21832032

  15. Sound pressure distribution and power flow within the gerbil ear canal from 100 Hz to 80 kHz

    PubMed Central

    Ravicz, Michael E.; Olson, Elizabeth S.; Rosowski, John J.

    2008-01-01

    Sound pressure was mapped in the bony ear canal of gerbils during closed-field sound stimulation at frequencies from 0.1 to 80 kHz. A 1.27-mm-diam probe-tube microphone or a 0.17-mm-diam fiber-optic miniature microphone was positioned along approximately longitudinal trajectories within the 2.3-mm-diam ear canal. Substantial spatial variations in sound pressure, sharp minima in magnitude, and half-cycle phase changes occurred at frequencies >30 kHz. The sound frequencies of these transitions increased with decreasing distance from the tympanic membrane (TM). Sound pressure measured orthogonally across the surface of the TM showed only small variations at frequencies below 60 kHz. Hence, the ear canal sound field can be described fairly well as a one-dimensional standing wave pattern. Ear-canal power reflectance estimated from longitudinal spatial variations was roughly constant at 0.2–0.5 at frequencies between 30 and 45 kHz. In contrast, reflectance increased at higher frequencies to at least 0.8 above 60 kHz. Sound pressure was also mapped in a microphone-terminated uniform tube—an “artificial ear.” Comparison with ear canal sound fields suggests that an artificial ear or “artificial cavity calibration” technique may underestimate the in situ sound pressure by 5–15 dB between 40 and 60 kHz. PMID:17902852

  16. Weak Defect Identification for Centrifugal Compressor Blade Crack Based on Pressure Sensors and Genetic Algorithm.

    PubMed

    Li, Hongkun; He, Changbo; Malekian, Reza; Li, Zhixiong

    2018-04-19

    The Centrifugal compressor is a piece of key equipment for petrochemical factories. As the core component of a compressor, the blades suffer periodic vibration and flow induced excitation mechanism, which will lead to the occurrence of crack defect. Moreover, the induced blade defect usually has a serious impact on the normal operation of compressors and the safety of operators. Therefore, an effective blade crack identification method is particularly important for the reliable operation of compressors. Conventional non-destructive testing and evaluation (NDT&E) methods can detect the blade defect effectively, however, the compressors should shut down during the testing process which is time-consuming and costly. In addition, it can be known these methods are not suitable for the long-term on-line condition monitoring and cannot identify the blade defect in time. Therefore, the effective on-line condition monitoring and weak defect identification method should be further studied and proposed. Considering the blade vibration information is difficult to measure directly, pressure sensors mounted on the casing are used to sample airflow pressure pulsation signal on-line near the rotating impeller for the purpose of monitoring the blade condition indirectly in this paper. A big problem is that the blade abnormal vibration amplitude induced by the crack is always small and this feature information will be much weaker in the pressure signal. Therefore, it is usually difficult to identify blade defect characteristic frequency embedded in pressure pulsation signal by general signal processing methods due to the weakness of the feature information and the interference of strong noise. In this paper, continuous wavelet transform (CWT) is used to pre-process the sampled signal first. Then, the method of bistable stochastic resonance (SR) based on Woods-Saxon and Gaussian (WSG) potential is applied to enhance the weak characteristic frequency contained in the pressure pulsation signal. Genetic algorithm (GA) is used to obtain optimal parameters for this SR system to improve its feature enhancement performance. The analysis result of experimental signal shows the validity of the proposed method for the enhancement and identification of weak defect characteristic. In the end, strain test is carried out to further verify the accuracy and reliability of the analysis result obtained by pressure pulsation signal.

  17. Weak Defect Identification for Centrifugal Compressor Blade Crack Based on Pressure Sensors and Genetic Algorithm

    PubMed Central

    Li, Hongkun; He, Changbo

    2018-01-01

    The Centrifugal compressor is a piece of key equipment for petrochemical factories. As the core component of a compressor, the blades suffer periodic vibration and flow induced excitation mechanism, which will lead to the occurrence of crack defect. Moreover, the induced blade defect usually has a serious impact on the normal operation of compressors and the safety of operators. Therefore, an effective blade crack identification method is particularly important for the reliable operation of compressors. Conventional non-destructive testing and evaluation (NDT&E) methods can detect the blade defect effectively, however, the compressors should shut down during the testing process which is time-consuming and costly. In addition, it can be known these methods are not suitable for the long-term on-line condition monitoring and cannot identify the blade defect in time. Therefore, the effective on-line condition monitoring and weak defect identification method should be further studied and proposed. Considering the blade vibration information is difficult to measure directly, pressure sensors mounted on the casing are used to sample airflow pressure pulsation signal on-line near the rotating impeller for the purpose of monitoring the blade condition indirectly in this paper. A big problem is that the blade abnormal vibration amplitude induced by the crack is always small and this feature information will be much weaker in the pressure signal. Therefore, it is usually difficult to identify blade defect characteristic frequency embedded in pressure pulsation signal by general signal processing methods due to the weakness of the feature information and the interference of strong noise. In this paper, continuous wavelet transform (CWT) is used to pre-process the sampled signal first. Then, the method of bistable stochastic resonance (SR) based on Woods-Saxon and Gaussian (WSG) potential is applied to enhance the weak characteristic frequency contained in the pressure pulsation signal. Genetic algorithm (GA) is used to obtain optimal parameters for this SR system to improve its feature enhancement performance. The analysis result of experimental signal shows the validity of the proposed method for the enhancement and identification of weak defect characteristic. In the end, strain test is carried out to further verify the accuracy and reliability of the analysis result obtained by pressure pulsation signal. PMID:29671821

  18. Effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss

    NASA Technical Reports Server (NTRS)

    Koval, L. R.

    1976-01-01

    In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. Flow is shown to provide a modest increase in TL that is uniform with frequency up to the critical frequency. The increase is about 2 dB at Mach number M = 0.5, and about 3.5 dB at M = 1. Above the critical frequency where TL is damping controlled, the increase can be slightly larger at certain frequencies. Curvature is found to stiffen the panel, thereby increasing the TL at low frequencies, but also to introduce a dip at the 'ring frequency' of a full cylinder having the same radius as the panel. Pressurization appears to produce a slight decrease in TL throughout the frequency range, and also slightly shifts the dips at the critical frequency and at the ring frequency.

  19. Human autonomic rhythms: vagal cardiac mechanisms in tetraplegic subjects

    NASA Technical Reports Server (NTRS)

    Koh, J.; Brown, T. E.; Beightol, L. A.; Ha, C. Y.; Eckberg, D. L.

    1994-01-01

    1. We studied eight young men (age range: 20-37 years) with chronic, clinically complete high cervical spinal cord injuries and ten age-matched healthy men to determine how interruption of connections between the central nervous system and spinal sympathetic motoneurones affects autonomic cardiovascular control. 2. Baseline diastolic pressures and R-R intervals (heart periods) were similar in the two groups. Slopes of R-R interval responses to brief neck pressure changes were significantly lower in tetraplegic than in healthy subjects, but slopes of R-R interval responses to steady-state arterial pressure reductions and increases were comparable. Plasma noradrenaline levels did not change significantly during steady-state arterial pressure reductions in tetraplegic patients, but rose sharply in healthy subjects. The range of arterial pressure and R-R interval responses to vasoactive drugs (nitroprusside and phenylephrine) was significantly greater in tetraplegic than healthy subjects. 3. Resting R-R interval spectral power at respiratory and low frequencies was similar in the two groups. During infusions of vasoactive drugs, low-frequency R-R interval spectral power was directly proportional to arterial pressure in tetraplegic patients, but was unrelated to arterial pressure in healthy subjects. Vagolytic doses of atropine nearly abolished both low- and respiratory-frequency R-R interval spectral power in both groups. 4. Our conclusions are as follows. First, since tetraplegic patients have significant levels of low-frequency arterial pressure and R-R interval spectral power, human Mayer arterial pressure waves may result from mechanisms that do not involve stimulation of spinal sympathetic motoneurones by brainstem neurones. Second, since in tetraplegic patients, low-frequency R-R interval spectral power is proportional to arterial pressure, it is likely to be mediated by a baroreflex mechanism. Third, since low-frequency R-R interval rhythms were nearly abolished by atropine in both tetraplegic and healthy subjects, these rhythms reflect in an important way rhythmic firing of vagal cardiac motoneurones.

  20. Optimization of Sm3+ fluorescence in Sm-doped yttrium aluminum garnet: Application to pressure calibration in diamond-anvil cell at high temperature

    NASA Astrophysics Data System (ADS)

    Sanchez-Valle, Carmen; Daniel, Isabelle; Reynard, Bruno; Abraham, Robert; Goutaudier, Christelle

    2002-10-01

    Sm3+ concentration in Sm-doped yttrium aluminum garnet (Sm3+):YAG has been optimized for fluorescence yield and synthesis procedure for the production of strain-free small grain-size powder established. Concentration of 0.5 wt % Sm3+ displays an optimal fluorescence signal, three to five times stronger than the generally proposed concentration (4 wt %). The fluorescence of the samples has been studied as a function of temperature (300-873 K) and pressure (0-15 GPa). A comparison with standard pressure scales shows that the pressure evolution of Sm3+:YAG fluorescence is insensitive to the doping rate, and that temperature has only a limited effect on the pressure scale established at 300 K. The present results indicate that pressure can be determined from the Y1 line of 0.5 wt % Sm-doped YAG, with temperature correction for pi at room pressure and constant pressure shift, within the 300-873 K and 10-4-15 GPa pressure-temperature range, through the linear relation: P (GPa)=0.127 x([pi0-0.018 xDelta]T)-[pi] where pi0 corresponds to the Y1 frequency value at ambient conditions (16 185 cm-1).

  1. Effect of ZrO2 on the sintering behavior, strength and high-frequency dielectric properties of electrical ceramic porcelain insulator

    NASA Astrophysics Data System (ADS)

    Singh Mehta, Niraj; Sahu, Praveen Kumar; Ershad, Md; Saxena, Vipul; Pyare, Ram; Ranjan Majhi, Manas

    2018-01-01

    In the present study, the effect of ZrO2 on the sintering, strength and dielectric behavior of electrical ceramic porcelain insulator with substituting alumina content by zirconia (in weight percentage from 0% to 30%) is investigated. The different composition of samples containing different zirconia (ZrO2) contents of 0, 10, 20, and 30 wt% are prepared using the uniaxial pressure technique applying 160 MPa pressure. Further, the prepared samples are also analyzed for sintering temperatures (1350 °C), and effects are observed on mechanical and electric properties of porcelain insulator. Different characterizations such as Dilatometer, x-ray diffraction, scanning electron microscopy and differential thermal analysis/thermo gravimetric analysis were used to evaluate the thermal, phase detection, micro structural and weight loss changes by increasing concentration of ZrO2 on base porcelain composition. At 1350 °C, for the composition having 20 wt% ZrO2 with 10 wt% alumina, the maximum density was observed 2.81 g cm-3 with a porosity of 2.23%. The highest tensile strength of 41 ± 3 MPa is observed for the same sample composition. The minimum value of thermal expansion coefficient is found to be in the range of 10-6 for the sample with 30 wt% ZrO2 content sintered at 1350 °C compared to other prepared samples. Similarly, the highest dielectric value (5.1-4.4) having dielectric loss (0.08-0.12) is achieved for the sample with 30 wt% ZrO2 content sintered at 1350 °C in the frequency range of 4-20 GHz at room temperature. According to the mechanical properties, the composition having 20 wt% ZrO2 on base ceramic porcelain composition has enormous potential to serve as a high strength refractory material. For dielectric properties, the composition having 30 wt% ZrO2 is more suitable for the electrical application.

  2. Development of multi-frequency ESR system for high-pressure measurements up to 2.5 GPa.

    PubMed

    Sakurai, T; Fujimoto, K; Matsui, R; Kawasaki, K; Okubo, S; Ohta, H; Matsubayashi, K; Uwatoko, Y; Tanaka, H

    2015-10-01

    A new piston-cylinder pressure cell for electron spin resonance (ESR) has been developed. The pressure cell consists of a double-layer hybrid-type cylinder with internal components made of the ZrO2-based ceramics. It can generate a pressure of 2 GPa repeatedly and reaches a maximum pressure of around 2.5 GPa. A high-pressure ESR system using a cryogen-free superconducting magnet up 10T has also been developed for this hybrid-type pressure cell. The frequency region is from 50 GHz to 400 GHz. This is the first time a pressure above 2 GPa has been achieved in multi-frequency ESR system using a piston-cylinder pressure cell. We demonstrate its potential by showing the results of the high-pressure ESR of the S=1 system with the single ion anisotropy NiSnCl6·6H2O and the S=1/2 quantum spin system CsCuCl3. We performed ESR measurements of these systems above 2 GPa successfully. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Ultrasound pressure distributions generated by high frequency transducers in large reactors.

    PubMed

    Leong, Thomas; Coventry, Michael; Swiergon, Piotr; Knoerzer, Kai; Juliano, Pablo

    2015-11-01

    The performance of an ultrasound reactor chamber relies on the sound pressure level achieved throughout the system. The active volume of a high frequency ultrasound chamber can be determined by the sound pressure penetration and distribution provided by the transducers. This work evaluated the sound pressure levels and uniformity achieved in water by selected commercial scale high frequency plate transducers without and with reflector plates. Sound pressure produced by ultrasonic plate transducers vertically operating at frequencies of 400 kHz (120 W) and 2 MHz (128 W) was characterized with hydrophones in a 2 m long chamber and their effective operating distance across the chamber's vertical cross section was determined. The 2 MHz transducer produced the highest pressure amplitude near the transducer surface, with a sharp decline of approximately 40% of the sound pressure occurring in the range between 55 and 155 mm from the transducer. The placement of a reflector plate 500 mm from the surface of the transducer was shown to improve the sound pressure uniformity of 2 MHz ultrasound. Ultrasound at 400 kHz was found to penetrate the fluid up to 2 m without significant losses. Furthermore, 400 kHz ultrasound generated a more uniform sound pressure distribution regardless of the presence or absence of a reflector plate. The choice of the transducer distance to the opposite reactor wall therefore depends on the transducer plate frequency selected. Based on pressure measurements in water, large scale 400 kHz reactor designs can consider larger transducer distance to opposite wall and larger active cross-section, and therefore can reach higher volumes than when using 2 MHz transducer plates. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  4. Pump and probe spectroscopy with continuous wave quantum cascade lasers.

    PubMed

    Kirkbride, James M R; Causier, Sarah K; Dalton, Andrew R; Weidmann, Damien; Ritchie, Grant A D

    2014-02-07

    This paper details infra-red pump and probe studies on nitric oxide conducted with two continuous wave quantum cascade lasers both operating around 5 μm. The pump laser prepares a velocity selected population in a chosen rotational quantum state of the v = 1 level which is subsequently probed using a second laser tuned to a rotational transition within the v = 2 ← v = 1 hot band. The rapid frequency scan of the probe (with respect to the molecular collision rate) in combination with the velocity selective pumping allows observation of marked rapid passage signatures in the transient absorption profiles from the polarized vibrationally excited sample. These coherent transient signals are influenced by the underlying hyperfine structure of the pump and probe transitions, the sample pressure, and the coherent properties of the lasers. Pulsed pump and probe studies show that the transient absorption signals decay within 1 μs at 50 mTorr total pressure, reflecting both the polarization and population dephasing times of the vibrationally excited sample. The experimental observations are supported by simulation based upon solving the optical Bloch equations for a two level system.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirkbride, James M. R.; Causier, Sarah K.; Dalton, Andrew R.

    This paper details infra-red pump and probe studies on nitric oxide conducted with two continuous wave quantum cascade lasers both operating around 5 μm. The pump laser prepares a velocity selected population in a chosen rotational quantum state of the v = 1 level which is subsequently probed using a second laser tuned to a rotational transition within the v = 2 ← v = 1 hot band. The rapid frequency scan of the probe (with respect to the molecular collision rate) in combination with the velocity selective pumping allows observation of marked rapid passage signatures in the transient absorptionmore » profiles from the polarized vibrationally excited sample. These coherent transient signals are influenced by the underlying hyperfine structure of the pump and probe transitions, the sample pressure, and the coherent properties of the lasers. Pulsed pump and probe studies show that the transient absorption signals decay within 1 μs at 50 mTorr total pressure, reflecting both the polarization and population dephasing times of the vibrationally excited sample. The experimental observations are supported by simulation based upon solving the optical Bloch equations for a two level system.« less

  6. Effects of experimentally measured pressure oscillations on the vibration of a solid rocket motor

    NASA Technical Reports Server (NTRS)

    Schoenster, J. A.; Pierce, H. B.

    1972-01-01

    Results are presented of firing a Nike rocket against a backstop for the purpose of obtaining pressure fluctuations in the rocket case and determining their relationship to structural vibrations of the case. Special care was required to obtain these pressure fluctuations because of the much higher static pressure generated in the rocket. Very small pressure fluctuations within the rocket case can cause significant vibration levels. A previously observed high frequency was shown to decrease with time before completely disappearing at about 1 second of burning time. The vibration of the case itself is probably related to the longitudinal structural modes at frequencies below 500 Hz and is dependent on local structural conditions at frequencies above this value.

  7. Portable Dynamic Pressure Calibrator

    NASA Technical Reports Server (NTRS)

    Wright, Morgan S.; Maynard, Everett (Technical Monitor)

    1996-01-01

    A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.

  8. GRAAL - Griggs-type Apparatus equipped with Acoustics in the Laboratory: a new instrument to explore the rheology of rocks at high pressure

    NASA Astrophysics Data System (ADS)

    Schubnel, A.; Champallier, R.; Precigout, J.; Pinquier, Y.; Ferrand, T. P.; Incel, S.; Hilairet, N.; Labrousse, L.; Renner, J.; Green, H. W., II; Stunitz, H.; Jolivet, L.

    2015-12-01

    Two new generation solid-medium Griggs-type apparatus have been set up at the Laboratoire de Géologie of ENS PARIS, and the Institut des Sciences de la Terre d'Orléans (ISTO). These new set-ups allow to perform controlled rock deformation experiments on large volume samples, up to 5 GPa and 1300°C. Careful pressure - stress calibration will be performed (using D-DIA and/or Paterson-type experiments as standards), strain-stress-pressure will be measured using modern techniques and state of the art salt assemblies. Focusing on rheology, the pressure vessel at ISTO has been designed in a goal of deforming large sample diameter (8 mm) at confining pressure of up to 3 GPa. Thanks to this large sample size, this new vessel will allow to explore the microstructures related to the deformation processes occurring at pressures of the deep lithosphere and in subduction zones. In this new apparatus, we moreover included a room below the pressure vessel in order to develop a basal load cell as close as possible to the sample. This new design, in progress, aims at significantly improving the accuracy of stress measurements in the Griggs-type apparatus. The ultimate goal is to set up a new technique able to routinely quantify the rheology of natural rocks between 0.5 and 5 GPa. Although fundamental to document the rheology of the lithosphere, such a technique is still missing in rock mechanics. Focusing on the evolution of physical and mechanical properties during mineral phase transformations, the vessel at ENS is equipped with continuous acoustic emission (AE) multi-sensor monitoring in order to "listen" to the sample during deformation. Indeed, these continuous recordings enable to detect regular AE like signals during dynamic crack propagation, as well as non-impulsive signals, which might be instrumental to identify laboratory analogs to non-volcanic tremor and low frequency earthquake signals. P and S elastic wave velocities will also be measured contemporaneously during deformation. Indeed, elastic wave velocities may be a good non-destructive proxy to track mineral reaction extent, under in-situ conditions. Attempts will also be performed to develop a tool to measure P and S wave anisotropy, at least along certain directions. Both data might prove of crucial interest to interpret the latest generation of tomographic imaging.

  9. Graphene Squeeze-Film Pressure Sensors.

    PubMed

    Dolleman, Robin J; Davidovikj, Dejan; Cartamil-Bueno, Santiago J; van der Zant, Herre S J; Steeneken, Peter G

    2016-01-13

    The operating principle of squeeze-film pressure sensors is based on the pressure dependence of a membrane's resonance frequency, caused by the compression of the surrounding gas which changes the resonator stiffness. To realize such sensors, not only strong and flexible membranes are required, but also minimization of the membrane's mass is essential to maximize responsivity. Here, we demonstrate the use of a few-layer graphene membrane as a squeeze-film pressure sensor. A clear pressure dependence of the membrane's resonant frequency is observed, with a frequency shift of 4 MHz between 8 and 1000 mbar. The sensor shows a reproducible response and no hysteresis. The measured responsivity of the device is 9000 Hz/mbar, which is a factor 45 higher than state-of-the-art MEMS-based squeeze-film pressure sensors while using a 25 times smaller membrane area.

  10. First-principles studies of PETN molecular crystal vibrational frequencies under high pressure

    NASA Astrophysics Data System (ADS)

    Perger, Warren; Zhao, Jijun

    2005-07-01

    The vibrational frequencies of the PETN molecular crystal were calculated using the first-principles CRYSTAL03 program which employs an all-electron LCAO approach and calculates analytic first derivatives of the total energy with respect to atomic displacements. Numerical second derivatives were used to enable calculation of the vibrational frequencies at ambient pressure and under various states of compression. Three different density functionals, B3LYP, PW91, and X3LYP were used to examine the effect of the exchange-correlation functional on the vibrational frequencies. The pressure-induced shift of the vibrational frequencies will be presented and compared with experiment. The average deviation with experimental results is shown to be on the order of 2-3%, depending on the functional used.

  11. Effects of Middle Ear Pressure on Otoacoustic Emission Measures.

    NASA Astrophysics Data System (ADS)

    Zhang, Ming

    1995-01-01

    Otoacoustic emissions (OAEs) are used extensively in hearing evaluations. Changes in middle ear pressure may have an effect on both forward and backward transmission of signals through the middle ear. The effect that such changes have on OAEs may depend on extent of pressure change, stimulus frequency, and stimulus level. This study quantitatively evaluates the effects of these variables on distortion product OAEs (DPOAEs) and cochlear microphonic distortion products (CMDPs) for a wide range of stimuli. Pigmented adult guinea pigs were experimental subjects. An animal surgical model was established to manipulate pressure in the middle ear and CMDP and DPOAE were simultaneously measured. The effects on forward transmission were determined from the CMDP data. It was assumed that the DPOAE measures were affected by changes in both forward and backward transmission. The effects on backward transmission were determined from the DPOAE data after the effect on forward transmission were subtracted out. For all conditions the frequency ratio rm f_2/f_1 was held at 1.2 and the level ratio rm L_1/L_2 was 10 dB. The effects on forward transmission were similar to those for backward transmission in all experimental conditions. Negative pressure had a greater effect than positive pressure. Positive pressures of +10 and +20 cmH_2O affected transmission for low frequency stimuli (f_2 = 1620 and 2680 Hz) but had little effect for high frequency stimuli (f_2 = 6980 and 10250 Hz). Negative pressures of -2.5 to -10 cmH_2O affected transmission across all frequencies tested. The effect at low frequencies is hypothesized to be related to tympanic membrane stiffness. The effect of negative pressure at high frequencies may be related to change in the incudostapedial joint. The slope of growth function decreased with the pressure change for DPOAEs but changed little for CMDPs. The decrease in slope for DPOAEs suggests that the level chosen for analysis can influence the result of the evaluation. In this study, such influence was minimized by averaging over a range of stimulus level. Finally it was noted that pressure could have a greater effect on OAE threshold (affected by both forward and backward transmission) than on behavioral threshold (affected only by forward transmission).

  12. Acoustic levitator for structure measurements on low temperature liquid droplets.

    PubMed

    Weber, J K R; Rey, C A; Neuefeind, J; Benmore, C J

    2009-08-01

    A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops of 1-3 mm in diameter at temperatures in the range -40 to +40 degrees C. The levitator comprised (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) an acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1 kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of approximately 22 kHz and could produce sound pressure levels of up to 160 dB. The force applied by the acoustic field could be modulated to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

  13. Acoustic levitator for structure measurements on low temperature liquid droplets

    NASA Astrophysics Data System (ADS)

    Weber, J. K. R.; Rey, C. A.; Neuefeind, J.; Benmore, C. J.

    2009-08-01

    A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops of 1-3 mm in diameter at temperatures in the range -40 to +40 °C. The levitator comprised (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) an acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1 kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ˜22 kHz and could produce sound pressure levels of up to 160 dB. The force applied by the acoustic field could be modulated to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

  14. The Physical Effects of Detonation in a Closed Cylindrical Chamber

    NASA Technical Reports Server (NTRS)

    Draper, C S

    1935-01-01

    Detonation in the internal-combustion engine is studied as a physical process. It is shown that detonation is accompanied by pressure waves within the cylinder charge. Sound theory is applied to the calculation of resonant pressure-wave frequencies. Apparatus is described for direct measurement of pressure-wave frequencies. Frequencies determined from two engines of different cylinder sizes are shown to agree with the values calculated from sound theory. An outline of the theoretically possible modes of vibration in a right circular cylinder with flat ends is included. An appendix by John P. Elting gives a method of calculating pressure in the sound wave following detonation.

  15. The slow collisional E×B ion drift characterized as the major instability mechanism of a poorly magnetized plasma column with an inward-directed radial electric field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierre, Thiéry

    2016-04-15

    The low-frequency instability of a cylindrical poorly magnetized plasma with an inward-directed radial electric field is studied changing the gas pressure and the ion cyclotron frequency. The unstable frequency always decreases when the gas pressure is increased indicating collisional effects. At a fixed pressure, the unstable frequency increases with the magnetic field when the B-field is low and decreases at larger magnetic field strength. We find that the transition between these two regimes is obtained when the ion cyclotron frequency equals the ion-neutrals collision frequency. This is in agreement with the theory of the slow-ion drift instability induced by themore » collisional slowing of the electric ion drift [A. Simon, Phys. Fluids 6, 382 (1963)].« less

  16. Dynamic Runner Forces and Pressure Fluctuations on the Draft Tube Wall of a Model Pump-Turbine

    NASA Astrophysics Data System (ADS)

    Kirschner, O.; Ruprecht, A.; Göde, E.; Riedelbauch, S.

    2016-11-01

    When Francis-turbines and pump-turbines operate at off-design conditions, typically a vortex rope develops. The vortex rope causes pressure oscillations leading to fluctuations of the forces affecting the runner. The presence of dynamic runner forces over a long period of time might damage the bearings and possibly the runner. In this experimental investigation, the fluctuating part of the runner forces and the pressure oscillations on the draft tube wall were measured on a model pump-turbine with a simplified straight cone draft tube in different operating conditions. The investigation focuses on the correlation of the pressure fluctuations frequency measured at the draft tube wall with the frequency of the fluctuating forces on the runner. The comparison between pressure fluctuations and dynamic forces shows a significant correlation in all operating points. For the comparison of different components in the spatial directions of the forces, the pressure fluctuations were separated in a synchronous part and a rotating part for operating points with higher amplitudes. The rotating pressure fluctuations correlate with the radial forces especially in the operating points with a rotating vortex rope. At frequencies with higher amplitudes in the pressure fluctuations caused by the vortex rope movement, there are also higher amplitudes in the radial forces at the same frequencies.

  17. Analysis of sound pressure levels emitted by children's toys.

    PubMed

    Sleifer, Pricila; Gonçalves, Maiara Santos; Tomasi, Marinês; Gomes, Erissandra

    2013-06-01

    To verify the levels of sound pressure emitted by non-certified children's toys. Cross-sectional study of sound toys available at popular retail stores of the so-called informal sector. Electronic, mechanical, and musical toys were analyzed. The measurement of each product was carried out by an acoustic engineer in an acoustically isolated booth, by a decibel meter. To obtain the sound parameters of intensity and frequency, the toys were set to produce sounds at a distance of 10 and 50cm from the researcher's ear. The intensity of sound pressure [dB(A)] and the frequency in hertz (Hz) were measured. 48 toys were evaluated. The mean sound pressure 10cm from the ear was 102±10 dB(A), and at 50cm, 94±8 dB(A), with p<0.05. The level of sound pressure emitted by the majority of toys was above 85dB(A). The frequency ranged from 413 to 6,635Hz, with 56.3% of toys emitting frequency higher than 2,000Hz. The majority of toys assessed in this research emitted a high level of sound pressure.

  18. Respiratory muscle activity and patient–ventilator asynchrony during different settings of noninvasive ventilation in stable hypercapnic COPD: does high inspiratory pressure lead to respiratory muscle unloading?

    PubMed Central

    Duiverman, Marieke L; Huberts, Anouk S; van Eykern, Leo A; Bladder, Gerrie; Wijkstra, Peter J

    2017-01-01

    Introduction High-intensity noninvasive ventilation (NIV) has been shown to improve outcomes in stable chronic obstructive pulmonary disease patients. However, there is insufficient knowledge about whether with this more controlled ventilatory mode optimal respiratory muscle unloading is provided without an increase in patient–ventilator asynchrony (PVA). Patients and methods Ten chronic obstructive pulmonary disease patients on home mechanical ventilation were included. Four different ventilatory settings were investigated in each patient in random order, each for 15 min, varying the inspiratory positive airway pressure and backup breathing frequency. With surface electromyography (EMG), activities of the intercostal muscles, diaphragm, and scalene muscles were determined. Furthermore, pressure tracings were derived simultaneously in order to assess PVA. Results Compared to spontaneous breathing, the most pronounced decrease in EMG activity was achieved with the high-pressure settings. Adding a high breathing frequency did reduce EMG activity per breath, while the decrease in EMG activity over 1 min was comparable with the high-pressure, low-frequency setting. With high backup breathing frequencies less breaths were pressure supported (25% vs 97%). PVAs occurred more frequently with the low-frequency settings (P=0.017). Conclusion High-intensity NIV might provide optimal unloading of respiratory muscles, without undue increases in PVA. PMID:28138234

  19. Respiratory muscle activity and patient-ventilator asynchrony during different settings of noninvasive ventilation in stable hypercapnic COPD: does high inspiratory pressure lead to respiratory muscle unloading?

    PubMed

    Duiverman, Marieke L; Huberts, Anouk S; van Eykern, Leo A; Bladder, Gerrie; Wijkstra, Peter J

    2017-01-01

    High-intensity noninvasive ventilation (NIV) has been shown to improve outcomes in stable chronic obstructive pulmonary disease patients. However, there is insufficient knowledge about whether with this more controlled ventilatory mode optimal respiratory muscle unloading is provided without an increase in patient-ventilator asynchrony (PVA). Ten chronic obstructive pulmonary disease patients on home mechanical ventilation were included. Four different ventilatory settings were investigated in each patient in random order, each for 15 min, varying the inspiratory positive airway pressure and backup breathing frequency. With surface electromyography (EMG), activities of the intercostal muscles, diaphragm, and scalene muscles were determined. Furthermore, pressure tracings were derived simultaneously in order to assess PVA. Compared to spontaneous breathing, the most pronounced decrease in EMG activity was achieved with the high-pressure settings. Adding a high breathing frequency did reduce EMG activity per breath, while the decrease in EMG activity over 1 min was comparable with the high-pressure, low-frequency setting. With high backup breathing frequencies less breaths were pressure supported (25% vs 97%). PVAs occurred more frequently with the low-frequency settings ( P =0.017). High-intensity NIV might provide optimal unloading of respiratory muscles, without undue increases in PVA.

  20. Fundamental relations between short-term RR interval and arterial pressure oscillations in humans

    NASA Technical Reports Server (NTRS)

    Taylor, J. A.; Eckberg, D. L.

    1996-01-01

    BACKGROUND: One of the principal explanations for respiratory sinus arrhythmia is that it reflects arterial baroreflex buffering of respiration-induced arterial pressure fluctuations. If this explanation is correct, then elimination of RR interval fluctuations should increase respiratory arterial pressure fluctuations. METHODS AND RESULTS: We measured RR interval and arterial pressure fluctuations during normal sinus rhythm and fixed-rate atrial pacing at 17.2+/-1.8 (SEM) beats per minute greater than the sinus rate in 16 healthy men and 4 healthy women, 20 to 34 years of age. Measurements were made during controlled-frequency breathing (15 breaths per minute or 0.25 Hz) with subjects in the supine and 40 degree head-up tilt positions. We characterized RR interval and arterial pressure variabilities in low-frequency (0.05 to 0.15 Hz) and respiratory-frequency (0.20 to 0.30 Hz) ranges with fast Fourier transform power spectra and used cross-spectral analysis to determine the phase relation between the two signals. As expected, cardiac pacing eliminated beat-to-beat RR interval variability. Against expectations, however, cardiac pacing in the supine position significantly reduced arterial pressure oscillations in the respiratory frequency (systolic, 6.8+/-1.8 to 2.9 +/-0.6 mm Hg2/Hz, P=.017). In contrast, cardiac pacing in the 40 degree tilt position increased arterial pressure variability (systolic, 8.0+/-1.8 to 10.8 +/-2.6, P=.027). Cross-spectral analysis showed that 40 degree tilt shifted the phase relation between systolic pressure and RR interval at the respiratory frequency from positive to negative (9 +/-7 degrees versus -17+/-11 degrees, P=.04); that is, in the supine position, RR interval changes appeared to lead arterial pressure changes, and in the upright position, RR interval changes appeared to follow arterial pressure changes. CONCLUSIONS: These results demonstrate that respiratory sinus arrhythmia can actually contribute to respiratory arterial pressure fluctuations. Therefore, respiratory sinus arrhythmia does not represent simple baroreflex buffering of arterial pressure.

  1. Ultrasonic speech translator and communications system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akerman, M.A.; Ayers, C.W.; Haynes, H.D.

    1996-07-23

    A wireless communication system undetectable by radio frequency methods for converting audio signals, including human voice, to electronic signals in the ultrasonic frequency range, transmitting the ultrasonic signal by way of acoustical pressure waves across a carrier medium, including gases, liquids, or solids, and reconverting the ultrasonic acoustical pressure waves back to the original audio signal. The ultrasonic speech translator and communication system includes an ultrasonic transmitting device and an ultrasonic receiving device. The ultrasonic transmitting device accepts as input an audio signal such as human voice input from a microphone or tape deck. The ultrasonic transmitting device frequency modulatesmore » an ultrasonic carrier signal with the audio signal producing a frequency modulated ultrasonic carrier signal, which is transmitted via acoustical pressure waves across a carrier medium such as gases, liquids or solids. The ultrasonic receiving device converts the frequency modulated ultrasonic acoustical pressure waves to a frequency modulated electronic signal, demodulates the audio signal from the ultrasonic carrier signal, and conditions the demodulated audio signal to reproduce the original audio signal at its output. 7 figs.« less

  2. Ultrasonic speech translator and communications system

    DOEpatents

    Akerman, M. Alfred; Ayers, Curtis W.; Haynes, Howard D.

    1996-01-01

    A wireless communication system undetectable by radio frequency methods for converting audio signals, including human voice, to electronic signals in the ultrasonic frequency range, transmitting the ultrasonic signal by way of acoustical pressure waves across a carrier medium, including gases, liquids, or solids, and reconverting the ultrasonic acoustical pressure waves back to the original audio signal. The ultrasonic speech translator and communication system (20) includes an ultrasonic transmitting device (100) and an ultrasonic receiving device (200). The ultrasonic transmitting device (100) accepts as input (115) an audio signal such as human voice input from a microphone (114) or tape deck. The ultrasonic transmitting device (100) frequency modulates an ultrasonic carrier signal with the audio signal producing a frequency modulated ultrasonic carrier signal, which is transmitted via acoustical pressure waves across a carrier medium such as gases, liquids or solids. The ultrasonic receiving device (200) converts the frequency modulated ultrasonic acoustical pressure waves to a frequency modulated electronic signal, demodulates the audio signal from the ultrasonic carrier signal, and conditions the demodulated audio signal to reproduce the original audio signal at its output (250).

  3. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  4. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  5. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    NASA Astrophysics Data System (ADS)

    Freifeld, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-10-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  6. Admittance–voltage profiling of Al{sub x}Ga{sub 1−x}N/GaN heterostructures: Frequency dependence of capacitance and conductance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Köhler, K.; Pletschen, W.; Godejohann, B.

    2015-11-28

    Admittance–voltage profiling of Al{sub x}Ga{sub 1−x}N/GaN heterostructures was used to determine the frequency dependent capacitance and conductance of FET devices in the frequency range from 50 Hz to 1 MHz. The nominally undoped low pressure metal-organic vapor-phase epitaxy structures were grown with an Al-content of 30%. An additional 1 nm thick AlN interlayer was placed in one structure before the Al{sub 0.3}Ga{sub 0.7}N layer growth. For frequencies below 10{sup 8} Hz it is convenient to use equivalent circuits to represent electric or dielectric properties of a material, a method widely used, for example, in impedance spectroscopy. We want to emphasize the relation betweenmore » frequency dependent admittance–voltage profiling and the corresponding equivalent circuits to the complex dielectric function. Debye and Drude models are used for the description of the frequency dependent admittance profiles in a range of depletion onset of the two-dimensional electron gas. Capacitance- and conductance-frequency profiles are fitted in the entire measured range by combining both models. Based on our results, we see contributions to the two-dimensional electron gas for our samples from surface states (80%) as well as from background doping in the Al{sub 0.3}Ga{sub 0.7}N barriers (20%). The specific resistance of the layers below the gate is above 10{sup 5} Ω cm for both samples and increases with increasing negative bias, i.e., the layers below the gate are essentially depleted. We propose that the resistance due to free charge carriers, determined by the Drude model, is located between gate and drain and, because of the AlN interlayer, the resistance is lowered by a factor of about 30 if compared to the sample without an AlN layer.« less

  7. The effects of sampling frequency on the climate statistics of the European Centre for Medium-Range Weather Forecasts

    NASA Astrophysics Data System (ADS)

    Phillips, Thomas J.; Gates, W. Lawrence; Arpe, Klaus

    1992-12-01

    The effects of sampling frequency on the first- and second-moment statistics of selected European Centre for Medium-Range Weather Forecasts (ECMWF) model variables are investigated in a simulation of "perpetual July" with a diurnal cycle included and with surface and atmospheric fields saved at hourly intervals. The shortest characteristic time scales (as determined by the e-folding time of lagged autocorrelation functions) are those of ground heat fluxes and temperatures, precipitation and runoff, convective processes, cloud properties, and atmospheric vertical motion, while the longest time scales are exhibited by soil temperature and moisture, surface pressure, and atmospheric specific humidity, temperature, and wind. The time scales of surface heat and momentum fluxes and of convective processes are substantially shorter over land than over oceans. An appropriate sampling frequency for each model variable is obtained by comparing the estimates of first- and second-moment statistics determined at intervals ranging from 2 to 24 hours with the "best" estimates obtained from hourly sampling. Relatively accurate estimation of first- and second-moment climate statistics (10% errors in means, 20% errors in variances) can be achieved by sampling a model variable at intervals that usually are longer than the bandwidth of its time series but that often are shorter than its characteristic time scale. For the surface variables, sampling at intervals that are nonintegral divisors of a 24-hour day yields relatively more accurate time-mean statistics because of a reduction in errors associated with aliasing of the diurnal cycle and higher-frequency harmonics. The superior estimates of first-moment statistics are accompanied by inferior estimates of the variance of the daily means due to the presence of systematic biases, but these probably can be avoided by defining a different measure of low-frequency variability. Estimates of the intradiurnal variance of accumulated precipitation and surface runoff also are strongly impacted by the length of the storage interval. In light of these results, several alternative strategies for storage of the EMWF model variables are recommended.

  8. Engineering Design and Testing of a Novel High-Resolution Trace-Metal Clean Sampler for Profiling and Long-term Deployment Applications

    NASA Astrophysics Data System (ADS)

    Mueller, A. V.; Crusius, J.; Carlson, K.; Chapin, T. P.

    2016-02-01

    Design, assembly, and testing of a novel in-situ sampler for automated high-frequency trace-metal clean sampling at ocean moorings was undertaken with the goal of improving marine data density for iron (and other metals) by up to a factor of ten relative to existing samplers. Target characteristics are: modular, flexible use (profiling, static moorings, AUV-deployed), high capacity (100-200 samples), low power, low cost ($3k per 100-samples), ability to collect filtered + unfiltered samples, and simple assembly. Smaller sample volumes (10mL) are enabled by recent innovations in analysis techniques, while use of off-the-shelf components enables lower cost and faster development time, although attention must be taken to verify trace-metal cleanliness of materials in commercial products. Standard polypropylene syringes (tips with lock fittings) are adapted as sample chambers through fabrication of a dual (viton) o-ring replacement plunger to prevent barrel contamination between acid washing and sample collection. Syringes are mounted along a (pumped) sampling channel machined into a modular custom-designed 7.5in. HDPE ring; successive rings stack, fitted around the central 3 in. PVC pressure housing containing the pump, batteries, and temperature and pressure sensors. Optional filtering (0.45um) is easily added at the inlet to the pumped sampling line. Syringes, pre-filled with acid for sample preservation, are held "closed" using plastic zipties connected to the plunger pull; individual syringes are selected for filling by breaking a 0.003in. wire (e.g., stainless steel, gold-plated tungsten/rhenium) with a pulse of current or by melting the ziptie loop using a nichrome wire. Multiplexed addressing minimizes required microcontroller output pins and wires between the free-flooded collection chamber and the pressure housing. A novel, custom rotating inlet mounting scheme ensures that the pump tubing inlet remains positioned approximately 1m upstream of the sampler.

  9. Micro acoustic resonant chambers for heating/agitating/mixing (MARCHAM)

    NASA Astrophysics Data System (ADS)

    Sherrit, Stewart; Noell, Aaron C.; Fisher, Anita M.; Takano, Nobuyuki; Grunthaner, Frank

    2016-04-01

    A variety of applications require the mixing and/or heating of a slurry made from a powder/fluid mixture. One of these applications, Sub Critical Water Extraction (SCWE), is a process where water and an environmental powder sample (sieved soil, drill cuttings, etc.) are heated in a sealed chamber to temperatures greater than 200 degrees Celsius by allowing the pressure to increase, but without reaching the critical point of water. At these temperatures, the ability of water to extract organics from solid particulate increases drastically. This paper describes the modeling and experimentation on the use of an acoustic resonant chamber which is part of an amino acid detection instrument called Astrobionibbler [Noell et al. 2014, 2015]. In this instrument we use acoustics to excite a fluid- solid fines mixture in different frequency/amplitude regimes to accomplish a variety of sample processing tasks. Driving the acoustic resonant chamber at lower frequencies can create circulation patterns in the fluid and mixes the liquid and fines, while driving the chamber at higher frequencies one can agitate the fluid and powder and create a suspension. If one then drives the chamber at high amplitude at resonance heating of the slurry occurs. In the mixing and agitating cell the particle levitation force depends on the relative densities and compressibility's of the particulate and fluid and on the kinetic and potential energy densities associated with the velocity and pressure fields [Glynne-Jones, Boltryk and Hill 2012] in the cell. When heating, the piezoelectric transducer and chamber is driven at high power in resonance where the solid/fines region is modelled as an acoustic transmission line with a large loss component. In this regime, heat is pumped into the solution/fines mixture and rapidly heats the sample. We have modeled the piezoelectric transducer/chamber/ sample using Mason's equivalent circuit. In order to assess the validity of the model we have built and tested a variety of chambers. This paper describes the experimental results which are in general agreement with theory within the limitations of the modeling.

  10. A Raman Spectroscopic Study of Kernite to 25 GPa

    NASA Astrophysics Data System (ADS)

    Silva, M. E.; O'Bannon, E. F., III; Williams, Q. C.

    2015-12-01

    A Raman spectroscopic study of kernite to 25 GPaMarcus Silva, Earl O'Bannon III, and Quentin Williams Department of Earth & Planetary Sciences, University of California Santa Cruz The Raman spectrum of kernite (Na2B4O6(OH)2·3(H2O)) has been characterized up to ~25 GPa in order to explore pressure-induced changes in a structurally novel mineral that contains mixed coordination borate groups (three- and four-fold), and both hydroxyl units and water. During compression, all of the ~30 modes monitored shift positively and monotonically until ~2.2 GPa where a few low frequency modes disappear and tetrahedral borate modes merge. The low frequency modes that disappear at ~2.2 GPa are likely associated with Na vibrations, and their disappearance suggests that dramatic changes occur in the Na sites at ~2.2 GPa. The merging of the boron bending and stretching modes at ~2.2 GPa suggests that the local symmetry of the BO4 tetrahedra changes at this pressure, and likely becomes more symmetric. The remaining modes shift positively up to ~7.4 GPa where a second notable change occurs. All but 5 modes (with initial frequencies of 150, 166, 289, 307, and 525 cm-1) disappear at ~7.4 GPa. This indicates that a second phase transition has occurred which affects both the BO3H and BO4­ groups: based on the loss of modes, this transition may be associated with disordering of the crystal. These 5 modes persist and shift monotonically up to ~25 GPa. On decompression, the 5 modes shift smoothly down to ~2.0 GPa where a few new modes appear in the spectrum. When fully decompressed to room pressure, the Raman spectrum of the recovered sample is significantly different from the ambient spectrum of the initial sample. Thus, our results are suggest a phase transition occurring at 2.2 GPa with changes in the Na and tetrahedral boron sites, followed by an additional transition at 7.4 GPa that may involve disordering of the crystal. In the latter transition, at least the BO3H groups appear to be destabilized, implying that the three-fold coordination of boron groups is, in contrast to the case of carbon, unstable in crystalline phases at relatively modest pressure conditions.

  11. Temperature gradient affects differentiation of gene expression and SNP allele frequencies in the dominant Lake Baikal zooplankton species.

    PubMed

    Bowman, Larry L; Kondrateva, Elizaveta S; Timofeyev, Maxim A; Yampolsky, Lev Y

    2018-06-01

    Local adaptation and phenotypic plasticity are main mechanisms of organisms' resilience in changing environments. Both are affected by gene flow and are expected to be weak in zooplankton populations inhabiting large continuous water bodies and strongly affected by currents. Lake Baikal, the deepest and one of the coldest lakes on Earth, experienced epilimnion temperature increase during the last 100 years, exposing Baikal's zooplankton to novel selective pressures. We obtained a partial transcriptome of Epischura baikalensis (Copepoda: Calanoida), the dominant component of Baikal's zooplankton, and estimated SNP allele frequencies and transcript abundances in samples from regions of Baikal that differ in multiyear average surface temperatures. The strongest signal in both SNP and transcript abundance differentiation is the SW-NE gradient along the 600+ km long axis of the lake, suggesting isolation by distance. SNP differentiation is stronger for nonsynonymous than synonymous SNPs and is paralleled by differential survival during a laboratory exposure to increased temperature, indicating directional selection operating on the temperature gradient. Transcript abundance, generally collinear with the SNP differentiation, shows samples from the warmest, less deep location clustering together with the southernmost samples. Differential expression is more frequent among transcripts orthologous to candidate thermal response genes previously identified in model arthropods, including genes encoding cytoskeleton proteins, heat-shock proteins, proteases, enzymes of central energy metabolism, lipid and antioxidant pathways. We conclude that the pivotal endemic zooplankton species in Lake Baikal exists under temperature-mediated selection and possesses both genetic variation and plasticity to respond to novel temperature-related environmental pressures. © 2018 John Wiley & Sons Ltd.

  12. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    PubMed Central

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.

    2011-01-01

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed. PMID:21520147

  13. Genetic selection pressure in TLR9 gene may enforce risk for SLE in Indian Tamils.

    PubMed

    Yusuf, J H; Kaliyaperumal, D; Jayaraman, M; Ramanathan, G; Devaraju, P

    2017-03-01

    Objectives Lupus is a classical systemic autoimmune disease with genetics as one of the well known causative factors for the disease pathogenesis. Toll-like receptors are the major pattern recognition receptors associated with innate immunity and also act as an interface with the adaptive immunity. Genetic polymorphisms in genes encoding TLRs were implicated in the development of infections, malignancies and autoimmune diseases. TLR9 is a member of TLR family, and recognizes the CpG DNA motifs of pathogens. Though the incidence rate of lupus in Asians was reported to be low (30 - 50/100,000 population), poor disease prognosis due to higher incidence of renal complications and aggressive disease worsens the scenario. The ability of TLR9 to detect and elicit an immune response against double-stranded DNA makes TLR9 a relevant factor to be tested for its association with the clinical and serological phenotypes of lupus. However, lack of relevant genetic data on normative frequencies of the TLR9 (rs187084) polymorphism may serve as a constraint to derive the sample size to conduct case control association studies. Hence this study was conducted to establish the normative frequency of TLR9 (rs187084) polymorphism in Indian Tamils. Materials and methods The TLR9 (rs187084) polymorphism was screened in South Indian Tamils ( n = 208) by PCR-RFLP. Results and discussion We observed a higher occurrence of the mutant allele (65%) in South Indian Tamils. No gender disparity with respect to the mutant allele frequency was observed. The higher incidence of mutant allele in both genders suggests that this population had undergone a genetic selection pressure as an evolutionary genetic measure to withstand the prevailing endemic infections like TB and malaria. Though the enhanced expression of TLR9 was protective against infections, it may also influence the development of autoimmune diseases. Conclusion The higher incidence of theTLR9 (rs187084) over-expression mutation in Indian Tamils is suggestive of a genetic adaptation or selection pressure to withstand the prevailing endemic infectious and parasitic diseases. However, this genetic adaptation poses a greater risk to develop autoimmune diseases like SLE etc through complex gene environment interactions. The normative frequency of the TLR9 (rs187084) polymorphism established in our population could now be used to define the sample size for future case control studies.

  14. Electrophysical properties of water and ice under isentropic compression to megabar pressures

    NASA Astrophysics Data System (ADS)

    Belov, S. I.; Boriskov, G. V.; Bykov, A. I.; Dolotenko, M. I.; Egorov, N. I.; Korshunov, A. S.; Kudasov, Yu. B.; Makarov, I. V.; Selemir, V. D.; Filippov, A. V.

    2017-02-01

    The relative permittivity and specific conductivity of water and ice are measured under isentropic compression to pressures above 300 GPa. Compression is initiated by a pulse of an ultrahigh magnetic field generated by an MK-1 magnetocumulative generator. The sample is placed in a coaxial compression chamber with an initial volume of about 40 cm3. The complex relative permittivity was measured by a fast-response reflectometer at a frequency of about 50 MHz. At the compression of water, its relative permittivity increases to ɛ = 350 at a pressure of 8 GPa, then drops sharply to ɛ = 140, and further decreases smoothly. It is shown that measurements of the relative permittivity under isentropic compression make it possible to determine interfaces between ordered and disordered phases of water and ice, as well as to reveal features associated with a change in the activation energy of defects.

  15. Patterns of Care and Treatment Target Success among Persons with Type 2 Diabetes Mellitus in Dubai: A Retrospective Cohort Study.

    PubMed

    Osenenko, Katherine M; Szabo, Shelagh M; Qatami, Lara; Korenblat Donato, Bonnie M; Al Madani, Abdulrazzak Ali; Al Awadi, Fatheya Fardallah; Al-Ansari, Jaber; Maclean, Ross; Levy, Adrian R

    2015-09-01

    Despite the high prevalence of type 2 diabetes mellitus (T2DM), few data exist describing its management in Dubai. This study characterized the treatment and estimated levels of glycemic, lipid, and blood pressure control among a sample with T2DM at a large Dubai Hospital. This retrospective cohort study systematically sampled charts from adults seeking care for T2DM from October 2009 to March 2010 until the target (N = 250) was reached. Data on patient characteristics, pharmacotherapy, complications, and laboratory testing were abstracted until September 2011. The frequency of treatments and modifications over the period was calculated, and measures of glycosylated hemoglobin A 1c , low-density lipoprotein, and blood pressure control were compared with guideline targets. Frequencies of complications were compared according to treatment type. One-third of the cohort comprised men, and the mean age was 58 years. At enrolment, the mean time from T2DM diagnosis was nearly 15 years and 74% had received insulin. During the study period, the most common regimens were insulin + oral combinations (55%) and oral combination therapy (39%). Overall, 67% received any insulin therapy during the study; and by study end, 78% had received insulin at any time. At the most recent assessment, guideline targets for glycosylated hemoglobin A 1c , blood pressure, and low-density lipoprotein were met by 23%, 29%, and 71%, respectively. Complications were more frequent among those treated with combination or insulin therapies. This study provides baseline data from Dubai for future comparisons of the effectiveness of new treatments, and to better understand the humanistic and economic burden of T2DM and its complications. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  16. Perceived parental food controlling practices are related to obesogenic or leptogenic child life style behaviors.

    PubMed

    Van Strien, Tatjana; van Niekerk, Rianne; Ouwens, Machteld A

    2009-08-01

    To better understand whether the parental food controlling practices pressure and restriction to eat are obesity preventing or obesity promoting, this study examined whether these parenting practices are related to other (food or non-food) areas that are generally regarded as obesogenic or leptogenic. Are these foods controlling practices more indicative of obesogenic or leptogenic child life style behaviors? In a sample of 7-12-year-old boys and girls (n = 943) the perceived parental food controlling practices were related to various measures for unhealthy life style. Using factor analysis we assessed whether there is a constellation of lifestyle behaviors that is potentially obesogenic or leptogenic. Remarkably, perceived parental restriction and pressure loaded on two different factors. Perceived parental restriction to eat had a negative loading on a factor that further comprised potential obesogenic child life style behaviors, such as snacking (positive loading), time spend with screen media (television or computer) (positive loadings) and frequency of fruit consumption (negative loading). Perceived parental pressure to eat had a positive loading on a factor that further comprised potential leptogenic life style behaviors such as frequency of eating a breakfast meal and sporting (positive loadings). It is concluded that low perceived parental restriction in regard to food may perhaps be a sign of more uninvolved 'neglecting' or indulgent parenting/obesogenic home environment, whereas high perceived parental pressure to eat may be sign of a more 'concerned' leptogenic parenting/home environment, though more research into style of parenting is needed.

  17. Analysis of chromosomal aberrations, sister-chromatid exchanges and micronuclei in peripheral lymphocytes of pharmacists before and after working with cytostatic drugs.

    PubMed

    Roth, S; Norppa, H; Järventaus, H; Kyyrönen, P; Ahonen, M; Lehtomäki, J; Sainio, H; Sorsa, M

    1994-12-01

    The frequencies of chromosome aberrations, SCEs and micronuclei (cytokinesis-block method) in blood lymphocytes were compared among six nonsmoking female pharmacists before and after 1 year of working with cytostatic drugs. All possible precautions were taken to avoid exposure to cytostatics, including proper protective clothing and a monitored, negative-pressured working environment with vertical laminar flow cabinet. As referents, an age-matched group of six nonsmoking female hospital workers not dealing with cytostatics was simultaneously sampled twice with the same time interval. The pharmacists showed a marginally higher mean frequency of SCEs/cell (6.3; P = 0.049) after the working period than 1 year earlier (5.8). On the other hand, the referents, with no obvious exposure, had a higher mean number of cells with chromatid-type aberrations, gaps excluded, in the second sampling (2.0%; P = 0.048) than in the first one (0.5%). In addition, a slight (P = 0.055) trend towards a higher frequency of micronucleated binucleate cells was observed in the second sampling for both the exposed and control subjects. As such findings suggest technical variation in the cytogenetic parameters, the small difference observed in SCEs for the pharmacists between the two samplings was probably not related to the cytostatics exposure. No statistically significant differences were observed for any of the cytogenetic parameters in comparisons between the pharmacists and the referents. The findings suggest that caution should be exercised in comparing results obtained from two different samplings in prospective cytogenetic studies.

  18. Monodisperse alginate microgel formation in a three-dimensional microfluidic droplet generator.

    PubMed

    Lian, Meng; Collier, C Patrick; Doktycz, Mitchel J; Retterer, Scott T

    2012-01-01

    Droplet based microfluidic systems provide an ideal platform for partitioning and manipulating aqueous samples for analysis. Identifying stable operating conditions under which droplets are generated is challenging yet crucial for real-world applications. A novel three-dimensional microfluidic platform that facilitates the consistent generation and gelation of alginate-calcium hydrogel microbeads for microbial encapsulation, over a broad range of input pressures, in the absence of surfactants is described. The unique three-dimensional design of the fluidic network utilizes a height difference at the junction between the aqueous sample injection and organic carrier channels to induce droplet formation via a surface tension enhanced self-shearing mechanism. Combined within a flow-focusing geometry, under constant pressure control, this arrangement facilitates predictable generation of droplets over a much broader range of operating conditions than that of conventional two-dimensional systems. The impact of operating pressures and geometry on droplet gelation, aqueous and organic material flow rates, microbead size, and bead generation frequency are described. The system presented provides a robust platform for encapsulating single microbes in complex mixtures into individual hydrogel beads, and provides the foundation for the development of a complete system for sorting and analyzing microbes at the single cell level.

  19. Monodisperse alginate microgel formation in a three-dimensional microfluidic droplet generator

    PubMed Central

    Lian, Meng; Collier, C. Patrick; Doktycz, Mitchel J.; Retterer, Scott T.

    2012-01-01

    Droplet based microfluidic systems provide an ideal platform for partitioning and manipulating aqueous samples for analysis. Identifying stable operating conditions under which droplets are generated is challenging yet crucial for real-world applications. A novel three-dimensional microfluidic platform that facilitates the consistent generation and gelation of alginate-calcium hydrogel microbeads for microbial encapsulation, over a broad range of input pressures, in the absence of surfactants is described. The unique three-dimensional design of the fluidic network utilizes a height difference at the junction between the aqueous sample injection and organic carrier channels to induce droplet formation via a surface tension enhanced self-shearing mechanism. Combined within a flow-focusing geometry, under constant pressure control, this arrangement facilitates predictable generation of droplets over a much broader range of operating conditions than that of conventional two-dimensional systems. The impact of operating pressures and geometry on droplet gelation, aqueous and organic material flow rates, microbead size, and bead generation frequency are described. The system presented provides a robust platform for encapsulating single microbes in complex mixtures into individual hydrogel beads, and provides the foundation for the development of a complete system for sorting and analyzing microbes at the single cell level. PMID:24198865

  20. Effect of neck geometry of resonance cells on noise reduction efficiency in sound-absorbing structures

    NASA Astrophysics Data System (ADS)

    Pisarev, P. V.; Anoshkin, A. N.; Pan'kov, A. A.

    2016-10-01

    The present work formulates the physical and mathematical models capable to forecast acoustic properties of resonance cells in sound absorbing structures. Distribution of acoustic pressure inside the duct and on sidewall cell was found, loss factor of output acoustic pressure wave was calculated for variety of geometric forms of cell's chamber and neck for monochromatic wave in 100-600Hz frequency range. Analysis of the acoustic pressure fields revealed that cell neck geometry strongly influences on cell resonant frequency and on outlet acoustic pressure loss factor. The effectiveness of the proposed by the authors biconical design of the resonant cell was proved, which increased acoustic radiation at the resonance frequency resulting significant increase of loss ratio of wave acoustic pressure at duct outlet.

  1. Raman spectroscopy and lattice dynamics of MgSiO3-perovskite at high pressure

    NASA Astrophysics Data System (ADS)

    Hemley, R. J.; Cohen, R. E.; Yeganeh-Haeri, A.; Mao, H. K.; Weidner, D. J.; Ito, E.

    Vibrational Raman spectra have been obtained for 50 to 100 μm single crystals of MgSiO3 perovskite in situ at high pressure. Seven bands were tracked as a function of pressure to 26 GPa using a diamond-anvil high-pressure cell with rare-gas pressure-transmitting media. The frequency shifts with pressure are positive, and no soft modes were observed, in agreement with the present and previous lattice dynamics calculations. Zero-pressure frequency shifts (dυi/dP)0 vary between 1.7 and 4.2 cm-1/GPa, which contrasts with the uniform shift of 2.6 cm-1/GPa for modes measured in high-pressure mid-infrared spectra. The mode-Grüneisen parameters γi, determined from the present data span the range 1.6-1.9, and are generally higher than those reported in the infrared study. The Raman data are interpreted using the lattice dynamics calculated from the potential-induced breathing (PIB) model, a Gordon-Kim approach that includes the effects of charge relaxation on the dynamics. Good agreement with the experimentally determined frequencies is obtained, particularly in the lower frequency range, in comparison with previous rigid-ion results. The high thermal expansivity for MgSiO3-perovskite is shown to be due to the comparatively high values for γi associated with the lower frequency modes. Thermal weighting of the individual γi is required for an accurate calculation of the thermal Grüneisen parameter γTH and thermal expansivity.

  2. X-radiography, XRD and Ultrasonic Data Transfer Function Technique - Simultaneous Measurements Under Simulated Mantle Conditions in a Multi-Anvil Device

    NASA Astrophysics Data System (ADS)

    Mueller, H. J.; Schilling, F. R.; Lathe, C.

    2004-05-01

    The interpretation of seismic data from the Earth's deep interior requires measurements of the physical properties of Earth materials under experimental simulated mantle conditions. Elastic wave velocity measurement is an important tool for the determination of the elastic properties. Ultrasonic interferometry allows the highly precise travel time measurement at a sample enclosed in a high-pressure multi-anvil device. But the calculation of wave velocities requires the exact sample length under in situ conditions. There are two options - scanning the interfaces of the sample by XRD (Mueller et al., 2003) and X-radiography (Li et al., 2001). The multi-anvil apparatus MAX80 is equipped for both methods. Only the X-radiography is fast enough for transient measurements. Contrary to XRD measurements, imaging the sample by X-rays requires a beam diameter larger than the sample length. Therefore the fixed primary slits of Max80 were exchanged by 4-blade high precision slits of Advanced Design Consulting, Inc. A Ce-YAG-crystal converts the X-ray image to an optical one, redirected by a mirror and captured by a CCD-camera. To derive the sample length, the different brightness of sample, buffer rod and reflector at the electronic image is evaluated. Classical ultrasonic interferometry is very time consuming, because the ultrasonic waves of the frequency range under study are generated and detected one after another with a given step rate. A 60 MHz frequency sweep with 100 kHz steps lasts for more than 30 minutes. This is a serious limitation for all transient measurements, but also limits the data collection at elevated temperatures to prevent the pressure transmitting boron epoxy cubes and the anvils from overheating. The ultrasonic transfer function technique (UTF), first described by Li et al. (2002), generates all the frequencies simultaneously. Related to the results and experiences of Li the UTF-technique was developed independently at GFZ. This version allows to consider the characteristics of the specific transducer-glue-anvil combination (Mueller et al., 2003). To collect the data for the following calculation of Vp and Vs requires just few seconds. The excitation function, applied to the transducer by an arbitrary waveform generator, is the result of the summation of all sinusoidal waves inside the frequency range. The response of the system - transducer - anvil - buffer rod - sample - reflector - for each of the frequencies can be reproduced by convoluting the resulting transfer function with these monochromatic waves step by step. Some recent results on the non-quenchable high-P - low-P clinoenstatite transition and to the quartz-coesite transition will be given to discuss the different interferometric techniques, including the XRD-data and X-radiography results, necessary to detect the phase transitions under in situ conditions and to measure the sample deformation. Li, B.; Vaughan, M.T.; Kung, J.; Weidner, D.J., NSLS Activity Report 2001, 2-103-106, (2001). Li, B.; Chen, K.; Kung, J.; Liebermann, R.C.; Weidner, D.J., J. Phys.: Condens. Matter 14, 11337-11342, (2002). Mueller, H.J.; Schilling, F.R.; Lauterjung, J.; Lathe, C., Eur. J. Mineral., 15, 865-873, (2003). Mueller, H.J.; Wunder, B.; Lathe, C.; Schilling, F.R.; Eur. J. Mineral., submitted, (2004).

  3. Fluctuating surface pressure measurements on USB wing using two types of transducers

    NASA Technical Reports Server (NTRS)

    Reed, J. B.

    1975-01-01

    Measurements of the fluctuating pressures on the wing surface of an upper-surface-blown powered-lift model and a JT15 engine were obtained using two types of pressure transducers. The pressures were measured using overall-fluctuating pressures and power spectral density analyses for various thrust settings and two jet impingement angles. Comparison of the data from the two transducers indicate that similar results are obtained in the lower frequency ranges for both transducers. The data also indicate that for this configuration, the highest pressure levels occur at frequencies below 2000 Hz.

  4. First-Principles Studies of Pentaerythritol Tetranitrate (PETN) Single Crystal Unit Cell Volumes and Vibrational Frequencies under Hydrostatic Pressure

    NASA Astrophysics Data System (ADS)

    Perger, Warren F.; Zhao, Jijun; Winey, J. M.; Gupta, Y. M.

    2006-07-01

    The vibrational frequencies of the PETN molecular crystal were calculated using the first-principles CRYSTAL03 program which employs an all-electron LCAO approach and calculates analytic first derivatives of the total energy with respect to atomic displacements. Numerical second derivatives were used to enable calculation of the vibrational frequencies at ambient pressure and under various states of compression. Three different density functionals, B3LYP, PW91, and X3LYP were used to examine the effect of the exchange-correlation functional on the vibrational frequencies. The average deviation with experimental results is shown to be on the order of 2-3%, depending on the functional used. The pressure-induced shift of the vibrational frequencies is presented.

  5. Effect of Training Frequency on Maximum Expiratory Pressure

    ERIC Educational Resources Information Center

    Anand, Supraja; El-Bashiti, Nour; Sapienza, Christine

    2012-01-01

    Purpose: To determine the effects of expiratory muscle strength training (EMST) frequency on maximum expiratory pressure (MEP). Method: We assigned 12 healthy participants to 2 groups of training frequency (3 days per week and 5 days per week). They completed a 4-week training program on an EMST trainer (Aspire Products, LLC). MEP was the primary…

  6. Dynamic pressure sensor calibration techniques offering expanded bandwidth with increased resolution

    NASA Astrophysics Data System (ADS)

    Wisniewiski, David

    2015-03-01

    Advancements in the aerospace, defense and energy markets are being made possible by increasingly more sophisticated systems and sub-systems which rely upon critical information to be conveyed from the physical environment being monitored through ever more specialized, extreme environment sensing components. One sensing parameter of particular interest is dynamic pressure measurement. Crossing the boundary of all three markets (i.e. aerospace, defense and energy) is dynamic pressure sensing which is used in research and development of gas turbine technology, and subsequently embedded into a control loop used for long-term monitoring. Applications include quantifying the effects of aircraft boundary layer ingestion into the engine inlet to provide a reliable and robust design. Another application includes optimization of combustor dynamics by "listening" to the acoustic signature so that fuel-to-air mixture can be adjusted in real-time to provide cost operating efficiencies and reduced NOx emissions. With the vast majority of pressure sensors supplied today being calibrated either statically or "quasi" statically, the dynamic response characterization of the frequency dependent sensitivity (i.e. transfer function) of the pressure sensor is noticeably absent. The shock tube has been shown to be an efficient vehicle to provide frequency response of pressure sensors from extremely high frequencies down to 500 Hz. Recent development activity has lowered this starting frequency; thereby augmenting the calibration bandwidth with increased frequency resolution so that as the pressure sensor is used in an actual test application, more understanding of the physical measurement can be ascertained by the end-user.

  7. Pressure Ulcer Risk and Prevention Practices in Pediatric Patients: A Secondary Analysis of Data from the National Database of Nursing Quality Indicators®.

    PubMed

    Razmus, Ivy; Bergquist-Beringer, Sandra

    2017-01-01

    Little is known about pressure ulcer prevention practice among pediatric patients. To describe the frequency of pressure ulcer risk assessment in pediatric patients and pressure ulcer prevention intervention use overall and by hospital unit type, a descriptive secondary analysis was performed of data submitted to the National Database for Nursing Quality Indicators® (NDNQI®) for at least 3 of the 4 quarters in 2012. Relevant data on pressure ulcer risk from 271 hospitals across the United States extracted from the NDNQI database included patient skin and pressure ulcer risk assessment on admission, time since the last pressure ulcer risk assessment, method used to assess pressure ulcer risk, and risk status. Extracted data on pressure ulcer prevention included skin assessment, pressure-redistribution surface use, routine repositioning, nutritional support, and moisture management. These data were organized by unit type and merged with data on hospital characteristics for the analysis. The sample included 39 984 patients ages 1 day to 18 years on 678 pediatric acute care units (general pediatrics, pediatric critical care units, neonatal intensive care units, pediatric step-down units, and pediatric rehabilitation units). Descriptive statistics were used to analyze study data. Most of the pediatric patients (33 644; 89.2%) were assessed for pressure ulcer risk within 24 hours of admission. The Braden Q Scale was frequently used to assess risk on general pediatrics units (75.4%), pediatric step-down units (85.5%), pediatric critical care units (81.3%), and pediatric rehabilitation units (56.1%). In the neonatal intensive care units, another scale or method was used more often (55% to 60%) to assess pressure ulcer risk. Of the 11 203 pediatric patients (39%) determined to be at risk for pressure ulcers, the majority (10 741, 95.8%) received some kind of pressure ulcer prevention intervention during the 24 hours preceding the NDNQI pressure ulcer survey. The frequency of prevention intervention use among those at risk ranged from 99.2% for skin assessment to 70.7% for redistribution surface use. Most pediatric patients are being assessed for pressure ulcer risk, but the implementation of interventions to prevent pressure ulcers among children needs to be improved. Future qualitative research should be conducted to determine how and when clinical judgment is used to assess pressure ulcer risk and the type of pressure-redistribution surfaces used among younger pediatric patients.

  8. Blood pressure documentation in the emergency department

    PubMed Central

    Daniel, Ana Carolina Queiroz Godoy; Machado, Juliana Pereira; Veiga, Eugenia Velludo

    2017-01-01

    ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department. PMID:28444085

  9. Fundamentals of Acoustics. Psychoacoustics and Hearing. Acoustical Measurements

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Ahumada, Al (Technical Monitor)

    1997-01-01

    These are 3 chapters that will appear in a book titled "Building Acoustical Design", edited by Charles Salter. They are designed to introduce the reader to fundamental concepts of acoustics, particularly as they relate to the built environment. "Fundamentals of Acoustics" reviews basic concepts of sound waveform frequency, pressure, and phase. "Psychoacoustics and Hearing" discusses the human interpretation sound pressure as loudness, particularly as a function of frequency. "Acoustic Measurements" gives a simple overview of the time and frequency weightings for sound pressure measurements that are used in acoustical work.

  10. Design and implementation of a new autonomous sensor fish to support advanced hydropower development.

    PubMed

    Deng, Z D; Lu, J; Myjak, M J; Martinez, J J; Tian, C; Morris, S J; Carlson, T J; Zhou, D; Hou, H

    2014-11-01

    Acceleration in development of additional conventional hydropower requires tools and methods to perform laboratory and in-field validation of turbine performance and fish passage claims. The new-generation Sensor Fish has been developed with more capabilities to accommodate a wider range of users over a broader range of turbine designs and operating environments. It provides in situ measurements of three-dimensional (3D) linear accelerations, 3D rotational velocities, 3D orientation, pressure, and temperature at a sampling frequency of 2048 Hz. It also has an automatic floatation system and built-in radio-frequency transmitter for recovery. The relative errors of the pressure, acceleration, and rotational velocity were within ±2%, ±5%, and ±5%, respectively. The accuracy of orientation was within ±4° and accuracy of temperature was ±2 °C. The new-generation Sensor Fish is becoming a major technology and being deployed for evaluating the conditions for fish passage of turbines or other hydraulic structures in both the United States and several other countries.

  11. The Prevalence of Annoyance and Effects after Long-Term Exposure to Low-Frequency Noise

    NASA Astrophysics Data System (ADS)

    PERSSON WAYE, K.; RYLANDER, R.

    2001-02-01

    A cross-sectional questionnaire and noise measurement survey was undertaken among 279 randomly chosen persons exposed to noise from heat pump/ventilation installations in their homes. The aim was to evaluate the prevalence of annoyance, disturbance of rest and concentration and the presence of psycho-social and medical symptoms in relation to noise exposure. Of the sample, 108 persons were exposed to a noise classified as of a low-frequency character (low-frequency noise exposed). As controls were chosen 171 persons living in similar residential areas, but exposed to a noise classified as of a mid-frequency character. The results showed that the prevalence of annoyance and disturbed concentration and rest was significantly higher among the persons exposed to low-frequency noise as compared to controls. Annoyance was suggested to be related to the sound pressure levels of the dominant low frequencies. The dB (A) noise levels did not predict annoyance. No significant differences in medical or psycho-social symptoms were found between the low-frequency noise exposed persons and controls. Among persons reporting themselves to be “rather” or “very” annoyed by low-frequency noise due to the heat pump/ventilation installations, a higher extent of psycho-social symptoms, sleep disturbance and headaches was found.

  12. Systems and methods for pressure and temperature measurement

    DOEpatents

    Challener, William Albert; Airey, Li

    2016-12-06

    A measurement system in one embodiment includes an acquisition module and a determination module. The acquisition module is configured to acquire resonant frequency information corresponding to a sensor disposed in a remote location from the acquisition module. The resonant frequency information includes first resonant frequency information for a first resonant frequency of the sensor corresponding to environmental conditions of the remote location, and also includes second resonant frequency information for a different, second resonant frequency of the sensor corresponding to the environmental conditions of the remote location. The determination module is configured to use the first resonant frequency information and the second resonant frequency information to determine the temperature and the pressure at the remote location.

  13. Spin polarization of {sup 87}Rb atoms with ultranarrow linewidth diode laser: Numerical simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Z. G.; Interdisciplinary Center of Quantum Information, National University of Defense Technology, Changsha, 410073; College of Science, National University of Defense Technology, Changsha, 410073

    2016-08-15

    In order to polarize {sup 87}Rb vapor effectively with ultranarrow linewidth diode laser, we studied the polarization as a function of some parameters including buffer gas pressure and laser power. Moreover, we also discussed the methods which split or modulate the diode laser frequency so as to pump the two ground hyperfine levels efficiently. We obtained some useful results through numerical simulation. If the buffer gas pressure is so high that the hyperfine structure is unresolved, the polarization is insensitive to laser frequency at peak absorption point so frequency splitting and frequency modulation methods do not show improvement. At lowmore » pressure and laser power large enough, where the hyperfine structure is clearly resolved, frequency splitting and frequency modulation methods can increase polarization effectively. For laser diodes, frequency modulation is easily realized with current modulation, so this method is attractive since it does not add any other components in the pumping laser system.« less

  14. Influence of the confining pressure on precursory and rupture processes of Westerly granite.

    NASA Astrophysics Data System (ADS)

    Passelegue, Francois; Nicolas, Aurelien; Madonna, Claudio; Schubnel, Alexandre

    2016-04-01

    In the shallow crust, brittle deformation mechanisms lead to damage and rupture of rocks. These mechanisms are generally described by non-linear stress relations and decrease of the elastic moduli due to microcrak opening and sliding. However, failure mode depends on confining pressure and ranges from axial splitting to shear localization. Here we report experiments on Westerly granite samples deformed under controlled upper crustal stress conditions in the laboratory. Experiments were conducted under triaxial loading (σ1>σ2=σ3) at confining pressures (σ3) ranging from 2 to 50 MPa (similar to upper crustal stress conditions) and at constant axial strain rate 10-5/s. Usual a dual gain system, a high frequency acoustic monitoring array recorded particles acceleration during macroscopic rupture of the intact specimen and premonitory background microseismicity. Secondly, acoustic sensors were used in an active way to measure the evolution of elastic wave velocities. In addition, we used an amplified strain gage to record the dynamic stress change during the dynamic rupture. Our preliminary results show that increasing confining pressure leads to the transition between axial cracks opening to shear localization. This result is supported by the moment tensor solutions of acoustic emissions and CT scan imaging of the post mortem sample. In addition, we systematically observe an exponential increase of the premonitory activity up to the shear failure of the sample. While the intensity of this precursory activity increase with the confining pressure in term of energy, the crack density leading to the failure of the sample is independent of the confinement. We show that the dynamic rupture occurs in only few microseconds, suggesting a rupture speed close to the shear wave velocity. In addition, the ratio between the stress drop and the peak of stress increases with the confinement. This result suggest that the weakening of faulting increases with the confinement. Finally, using both dynamic stress drop and axial displacement measurement, we show that the fracture energy increases with both confining pressure and seismic slip.

  15. A Microwave Pressure Sounder

    NASA Technical Reports Server (NTRS)

    Flower, D. A.; Peckham, G. E.

    1978-01-01

    An instrument to measure atmospheric pressure at the earth's surface from an orbiting satellite would be a valuable addition to the expanding inventory of remote sensors. The subject of this report is such an instrument - the Microwave Pressure Sounder (MPS). It is shown that global-ocean coverage is attainable with sufficient accuracy, resolution and observational frequency for meteorological, oceanographic and climate research applications. Surface pressure can be deduced from a measurement of the absorption by an atmospheric column at a frequency in the wing of the oxygen band centered on 60 GHz. An active multifrequency instrument is needed to make this measurement with sufficient accuracy. The selection of optimum operating frequencies is based upon accepted models of surface reflection, oxygen, water vapor and cloud absorption. Numerical simulation using a range of real atmospheres defined by radiosonde observations were used to validate the frequency selection procedure. Analyses are presented of alternative system configurations that define the balance between accuracy and achievable resolution.

  16. Numerical investigation on pressure fluctuations in centrifugal compressor with different inlet guide vanes pre-whirl angles

    NASA Astrophysics Data System (ADS)

    Wang, Y. C.; Shi, M.; Cao, S. L.; Li, Z. H.

    2013-12-01

    The pressure fluctuations in a centrifugal compressor with different inlet guide vanes (IGV) pre-whirl angles were investigated numerically, as well as the pre-stress model and static structural of blade. The natural frequency was evaluated by pre-stress model analysis. The results show that, the aero-dynamic pressure acting on blade surface is smaller than rotation pre-stress, which wouldn't result in large deformation of blade. The natural frequencies with rotation pre-stress are slightly higher than without rotation pre-stress. The leading mechanism of pressure fluctuations for normal conditions is the rotor-stator (IGVs) interaction, while is serious flow separations for conditions that are close to surge line. A few frequency components in spectra are close to natural frequency, which possibly result in resonant vibration if amplitude is large enough, which is dangerous for compressor working, and should be avoided.

  17. An optimal frequency range for assessing the pressure reactivity index in patients with traumatic brain injury.

    PubMed

    Howells, Tim; Johnson, Ulf; McKelvey, Tomas; Enblad, Per

    2015-02-01

    The objective of this study was to identify the optimal frequency range for computing the pressure reactivity index (PRx). PRx is a clinical method for assessing cerebral pressure autoregulation based on the correlation of spontaneous variations of arterial blood pressure (ABP) and intracranial pressure (ICP). Our hypothesis was that optimizing the methodology for computing PRx in this way could produce a more stable, reliable and clinically useful index of autoregulation status. The patients studied were a series of 131 traumatic brain injury patients. Pressure reactivity indices were computed in various frequency bands during the first 4 days following injury using bandpass filtering of the input ABP and ICP signals. Patient outcome was assessed using the extended Glasgow Outcome Scale (GOSe). The optimization criterion was the strength of the correlation with GOSe of the mean index value over the first 4 days following injury. Stability of the indices was measured as the mean absolute deviation of the minute by minute index value from 30-min moving averages. The optimal index frequency range for prediction of outcome was identified as 0.018-0.067 Hz (oscillations with periods from 55 to 15 s). The index based on this frequency range correlated with GOSe with ρ=-0.46 compared to -0.41 for standard PRx, and reduced the 30-min variation by 23%.

  18. Knockdown Resistance Allele Frequencies in North American Head Louse (Anoplura: Pediculidae) Populations

    PubMed Central

    Yoon, Kyong Sup; Previte, Domenic J.; Hodgdon, Hilliary E.; Poole, Bryan C.; Kwon, Deok Ho; El-Ghar, Gamal E. Abo; Lee, Si Hyeock; Clark, J. Marshall

    2014-01-01

    The study examines the extent and frequency of a knockdown-type resistance allele (kdr type) in North American populations of human head lice. Lice were collected from 32 locations in Canada and the United States. DNA was extracted from individual lice and used to determine their zygosity using the serial invasive signal amplification technique to detect the kdr-type T917I (TI) mutation, which is most responsible for nerve insensitivity that results in the kdr phenotype and permethrin resistance. Previously sampled sites were resampled to determine if the frequency of the TI mutation was changing. The TI frequency was also reevaluated using a quantitative sequencing method on pooled DNA samples from selected sites to validate this population genotyping method. Genotyping substantiated that TI occurs at high levels in North American lice (88.4%). Overall, the TI frequency in U.S. lice was 84.4% from 1999 to 2009, increased to 99.6% from 2007 to 2009, and was 97.1% in Canadian lice in 2008. Genotyping results using the serial invasive signal amplification reaction (99.54%) and quantitative sequencing (99.45%) techniques were highly correlated. Thus, the frequencies of TI in North American head louse populations were found to be uniformly high, which may be due to the high selection pressure from the intensive and widespread use of the pyrethrins- or pyrethroid-based pediculicides over many years, and is likely a main cause of increased pediculosis and failure of pyrethrins- or permethrin-based products in Canada and the United States. Alternative approaches to treatment of head lice infestations are critically needed. PMID:24724296

  19. Comparison of low-frequency noise levels of the Concorde supersonic transport with other commercial service airplanes

    NASA Technical Reports Server (NTRS)

    Powell, C. A.; Mccurdy, D. A.

    1978-01-01

    Fifty-two airplane noise recordings, made at several locations around Dulles International Airport, were analyzed to compare the low-frequency noise levels of the Concorde supersonic transport with those of other commercial jet airplanes. Comparisons of the relative low-frequency noise levels which were produced at close and distant locations for departures and arrivals were made for three noise measures: the sound pressure level in the 1/3 octave band centered at 20 Hz, the total sound pressure level in the 1/3 octave bands with center frequencies less than or equal to 125 Hz, and the total sound pressure level in the 1/3 octave bands with center frequencies less than or equal to 500 Hz. Although the absolute noise levels for Concorde were found, in general, to be higher than those for the other airplane types, the level of low-frequency noise of the Concorde relative to the perceived noise level (PNL), effective perceived noise level (EPNL), and overall sound pressure level (OASPL) was within the range established by the other airplane types, except for the arrival operations of four-engine, narrow-body airplanes. The measure OASPL was found to be a significantly better predictor of low-frequency noise level than PNL or EPNL.

  20. Effect of annealing time, weight pressure and cobalt doping on the electrical and magnetic behavior of barium titanate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samuvel, K., E-mail: kssamuvel@gmail.com; Ramachandran, K., E-mail: ramach76@yahoo.com

    2016-05-06

    BaTi{sub 0.5}CO{sub 0.5}O{sub 3} (BTCO) nanoparticles were prepared by the solid state reaction technique using different starting materials and the microstructure examined by XRD, FESEM, BDS and VSM. X-ray diffraction and electron diffraction patterns showed that the nanoparticles were the tetragonal BTCO phase. The BTCO nanoparticles prepared from the starting materials of as prepared titanium-oxide, Cobalt -oxide and barium carbonate have spherical grain morphology, an average size of 65 nm and a fairly narrow size distribution. The nano-scale presence and the formation of the tetragonal perovskite phase as well as the crystallinity were detected using the mentioned techniques. Dielectric properties ofmore » the samples were measured at different frequencies. Broadband dielectric spectroscopy is applied to investigate the electrical properties of disordered perovskite-like ceramics in a wide temperature range. The doped BTCO samples exhibited low loss factor at 1 kHz and 1 MHz frequencies respectively.« less

  1. Coordinate interferometric system for measuring the position of a sample with infrared telecom laser diode

    NASA Astrophysics Data System (ADS)

    Holá, Miroslava; Lazar, Josef; Čížek, Martin; Hucl, Václav; Řeřucha, Šimon; Číp, Ondřej

    2016-11-01

    We report on a design of an interferometric position measuring system for control of a sample stage in an e-beam writer with reproducibility of the position on nanometer level and resolution below nanometer. We introduced differential configuration of the interferometer where the position is measured with respect to a central reference point to eliminate deformations caused by thermal and pressure effects on the vacuum chamber. The reference is here the electron gun of the writer. The interferometer is designed to operate at infrared, telecommunication wavelength due to the risk of interference of stray light with sensitive photodetectors in the chamber. The laser source is here a narrow-linewidth DFB laser diode with electronics of our own design offering precision and stability of temperature and current, low-noise, protection from rf interference, and high-frequency modulation. Detection of the interferometric signal relies on a novel derivative technique utilizing hf frequency modulation and phase-sensitive detection.

  2. Nonlinear elasticity in rocks: A comprehensive three-dimensional description

    DOE PAGES

    Lott, Martin; Remillieux, Marcel; Garnier, Vincent; ...

    2017-07-17

    Here we study theoretically and experimentally the mechanisms of nonlinear and nonequilibrium dynamics in geomaterials through dynamic acoustoelasticity testing. In the proposed theoretical formulation, the classical theory of nonlinear elasticity is extended to include the effects of conditioning. This formulation is adapted to the context of dynamic acoustoelasticity testing in which a low-frequency “pump” wave induces a strain field in the sample and modulates the propagation of a high-frequency “probe” wave. Experiments are conducted to validate the formulation in a long thin bar of Berea sandstone. Several configurations of the pump and probe are examined: the pump successively consists ofmore » the first longitudinal and first torsional mode of vibration of the sample while the probe is successively based on (pressure) $P$ and (shear) $S$ waves. The theoretical predictions reproduce many features of the elastic response observed experimentally, in particular, the coupling between nonlinear and nonequilibrium dynamics and the three-dimensional effects resulting from the tensorial nature of elasticity.« less

  3. Radial breathing mode of carbon nanotubes subjected to axial pressure

    PubMed Central

    2011-01-01

    In this paper, a theoretical analysis of the radial breathing mode (RBM) of carbon nanotubes (CNTs) subjected to axial pressure is presented based on an elastic continuum model. Single-walled carbon nanotubes (SWCNTs) are described as an individual elastic shell and double-walled carbon nanotubes (DWCNTs) are considered to be two shells coupled through the van der Waals force. The effects of axial pressure, wave numbers and nanotube diameter on the RBM frequency are investigated in detail. The validity of these theoretical results is confirmed through the comparison of the experiment, calculation and simulation. Our results show that the RBM frequency is linearly dependent on the axial pressure and is affected by the wave numbers. We concluded that RBM frequency can be used to characterize the axial pressure acting on both ends of a CNT. PMID:21834961

  4. Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity

    DOE PAGES

    Parise, M.

    2018-05-18

    The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less

  5. Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parise, M.

    The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less

  6. Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity

    NASA Astrophysics Data System (ADS)

    Parise, M.

    2018-05-01

    The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effective tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.

  7. Prediction of the Lorentz Force Detuning and Pressure Sensitivity for a Pillbox Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parise, M.

    2018-04-23

    The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less

  8. Polaron hopping in olivine phosphates studied by nuclear resonant scattering

    NASA Astrophysics Data System (ADS)

    Tracy, Sally June

    Valence fluctuations of Fe2+ and Fe3+ were studied in a solid solution of LixFePO4 by nuclear resonant forward scattering of synchrotron x rays while the sample was heated in a diamond-anvil pressure cell. The spectra acquired at different temperatures and pressures were analyzed for the frequencies of valence changes using the Blume-Tjon model of a system with a fluctuating Hamiltonian. These frequencies were analyzed to obtain activation energies and an activation volume for polaron hopping. There was a large suppression of hopping frequency with pressure, giving an anomalously large activation volume. This large, positive value is typical of ion diffusion, which indicates correlated motions of polarons, and Li+ ions that alter the dynamics of both. In a parallel study of NaxFePO4, the interplay between sodium ordering and electron mobility was investigated using a combination of synchrotron x-ray diffraction and nuclear resonant scattering. Conventional Mossbauer spectra were collected while the sample was heated in a resistive furnace. An analysis of the temperature evolution of the spectral shapes was used to identify the onset of fast electron hopping and determine the polaron hopping rate. Synchrotron x-ray diffraction measurements were carried out in the same temperature range. Reitveld analysis of the diffraction patterns was used to determine the temperature of sodium redistribution on the lattice. The diffraction analysis also provides new information about the phase stability of the system. The temperature evolution of the iron site occupancies from the Mossbauer measurements, combined with the synchrotron diffraction results give strong evidence for a relationship between the onset of fast electron dynamics and the redistribution of sodium in the lattice. Measurements of activation barriers for polaron hopping gave fundamental insights about the correlation between electronic carriers and mobile ions. This work established that polaron-ion interactions can alter the local dynamics of electron and ion transport. These types of coupled processes may be common in many materials used for battery electrodes, and new details concerning the influence of polaron-ion interactions on the charge dynamics are relevant to optimizing their electrochemical performance.

  9. Pressure Fluctuations Induced by a Hypersonic Turbulent Boundary Layer

    NASA Technical Reports Server (NTRS)

    Duan, Lian; Choudhari, Meelan M.; Zhang, Chao

    2016-01-01

    Direct numerical simulations (DNS) are used to examine the pressure fluctuations generated by a spatially-developed Mach 5.86 turbulent boundary layer. The unsteady pressure field is analyzed at multiple wall-normal locations, including those at the wall, within the boundary layer (including inner layer, the log layer, and the outer layer), and in the free stream. The statistical and structural variations of pressure fluctuations as a function of wall-normal distance are highlighted. Computational predictions for mean velocity pro les and surface pressure spectrum are in good agreement with experimental measurements, providing a first ever comparison of this type at hypersonic Mach numbers. The simulation shows that the dominant frequency of boundary-layer-induced pressure fluctuations shifts to lower frequencies as the location of interest moves away from the wall. The pressure wave propagates with a speed nearly equal to the local mean velocity within the boundary layer (except in the immediate vicinity of the wall) while the propagation speed deviates from the Taylor's hypothesis in the free stream. Compared with the surface pressure fluctuations, which are primarily vortical, the acoustic pressure fluctuations in the free stream exhibit a significantly lower dominant frequency, a greater spatial extent, and a smaller bulk propagation speed. The freestream pressure structures are found to have similar Lagrangian time and spatial scales as the acoustic sources near the wall. As the Mach number increases, the freestream acoustic fluctuations exhibit increased radiation intensity, enhanced energy content at high frequencies, shallower orientation of wave fronts with respect to the flow direction, and larger propagation velocity.

  10. Electric properties of nanostructure (FeCoZr)x(CaF2)(100-x) produced in argon Ar atmosphere

    NASA Astrophysics Data System (ADS)

    Bondariev, Vitalii; Czarnacka, Karolina; Boiko, Oleksandr

    2015-09-01

    The paper presents frequency f and temperature Tp dependences of conductivity σ, capacitance Cp and phase shift angle θ for the nanocomposite metal-dielectric (FeCoZr)x(CaF2)(100-x). Samples of nanocomposite were produced by ion-beam sputtering in pure argon Ar atmosphere. Partial pressure of gas Ar in the ion source pAr=1.1×10-1Pa. Contains of metallic phase in tested sample is x = 54.6 at.%. Studies carried out by stand to measuring of AC electrical properties of nanocomposites and semiconductors. The measurements have been performed using alternating current within the frequency range of 50 Hz - 1 MHz for measuring temperatures ranging from 77 K to 373 K. On the frequency-temperature dependence of phase shift angle θ at low frequencies phase shift have capacitive character and at high frequencies - inductive. Position of fmin on the frequency dependence on capacitance Cp corresponds exactly to the resonance frequency fR for which the angle θ crosses zero. Analysis of the results showed that phenomena similar to phenomena in conventional circuit RLC occur in the nanocomposite (CoFeZr)54.6(CaF2)45.4. Jumping recharging between the defects leads to the formation of dipoles and consequently to the increase of permittivity. After a time τ electron returns to the first defect and dipole disappears. The formation of inductance in nanocomposite is associated with return jumps of electrons from defect with negative charge to the defect with positive charge, set by the time, which are characterized by low values of activation energy.

  11. Relationship between blood pressure and cerebral blood flow during supine cycling: influence of aging

    PubMed Central

    Hoffman, Keegan; Tzeng, Yu-Chieh; Hansen, Alex; Ainslie, Philip N.

    2015-01-01

    The cerebral pressure-flow relationship can be quantified as a high-pass filter, where slow oscillations are buffered (<0.20 Hz) and faster oscillations are passed through relatively unimpeded. During moderate intensity exercise, previous studies have reported paradoxical transfer function analysis (TFA) findings (altered phase or intact gain). This study aimed to determine whether these previous findings accurately represent this relationship. Both younger (20–30 yr; n = 10) and older (62–72 yr; n = 9) adults were examined. To enhance the signal-to-noise ratio, large oscillations in blood pressure (via oscillatory lower body negative pressure; OLBNP) were induced during steady-state moderate intensity supine exercise (∼45–50% of heart rate reserve). Beat-to-beat blood pressure, cerebral blood velocity, and end-tidal Pco2 were monitored. Very low frequency (0.02–0.07 Hz) and low frequency (0.07–0.20 Hz) range spontaneous data were quantified. Driven OLBNP point estimates were sampled at 0.05 and 0.10 Hz. The OLBNP maneuvers augmented coherence to >0.97 at 0.05 Hz and >0.98 at 0.10 Hz in both age groups. The OLBNP protocol conclusively revealed the cerebrovascular system functions as a high-pass filter during exercise throughout aging. It was also discovered that the older adults had elevations (+71%) in normalized gain (+0.46 ± 0.36%/%: 0.05 Hz) and reductions (−34%) in phase (−0.24 ± 0.22 radian: 0.10 Hz). There were also age-related phase differences between resting and exercise conditions. It is speculated that these age-related changes in the TFA metrics are mediated by alterations in vasoactive factors, sympathetic tone, or the mechanical buffering of the compliance vessels. PMID:26586907

  12. Regenerator Operation at Very High Frequencies for Microcryocoolers

    NASA Astrophysics Data System (ADS)

    Radebaugh, Ray; O'Gallagher, Agnes

    2006-04-01

    The size of Stirling and Stirling-type pulse tube cryocoolers is dominated by the size of the pressure oscillator. Such cryocoolers typically operate at frequencies up to about 60 Hz for cold-end temperatures above about 60 K. Higher operating frequencies would allow the size and mass of the pressure oscillator to be reduced for a given power input. However, simply increasing the operating frequency leads to large losses in the regenerator. The simple analytical equations derived here show how the right combination of frequency and pressure, along with optimized regenerator geometry, can lead to successful regenerator operation at frequencies up to 1 kHz. Efficient regenerator operation at such high frequencies is possible only with pressures of about 5 to 8 MPa and with very small hydraulic diameters and lengths. Other geometrical parameters must also be optimized for such conditions. The analytical equations are used to provide guidance to the right combination of parameters. We give example numerical calculations with REGEN3.2 in the paper for 60 Hz, 400 Hz, and 1000 Hz operation of optimized screen regenerators and show that the coefficient of performance at 400 Hz and 1000 Hz is about 78 % and 68 %, respectively, of that for 60 Hz when an average pressure of 7 MPa is used with the higher frequency, compared with 2.5 MPa for 60 Hz operation. The 1000 Hz coefficient of performance for parallel tubes is about the same as that of the screen geometry at 60 Hz. The compressor and cold-end swept volumes are reduced by a factor of 47 at 1000 Hz, compared with the 60 Hz case for the same input acoustic power, which can enable the development of microcryocoolers for MEMS applications.

  13. Numerical Investigations of High Pressure Acoustic Waves in Resonators

    NASA Technical Reports Server (NTRS)

    Athavale, Mahesh; Pindera, Maciej; Daniels, Christopher C.; Steinetz, Bruce M.

    2004-01-01

    This presentation presents work on numerical investigations of nonlinear acoustic phenomena in resonators that can generate high-pressure waves using acoustic forcing of the flow. Time-accurate simulations of the flow in a closed cone resonator were performed at different oscillation frequencies and amplitudes, and the numerical results for the resonance frequency and fluid pressure increase match the GRC experimental data well. Work on cone resonator assembly simulations has started and will involve calculations of the flow through the resonator assembly with and without acoustic excitation. A new technique for direct calculation of resonance frequency of complex shaped resonators is also being investigated. Script-driven command procedures will also be developed for optimization of the resonator shape for maximum pressure increase.

  14. [A Feasibility Study of closing the small bowel with high-frequency welding device].

    PubMed

    Zhou, Huabin; Han, Shuai; Chen, Jun; Huang, Dequn; Peng, Liang; Ning, Jingxuan; Li, Zhou

    2014-12-01

    This study aimed to evaluate the feasibility and effectiveness of closing the small bowel in an ex vivo porcine model with high-frequency welding device. A total of 100 porcine small bowels were divided into two groups, and then were closed with two different methods. The fifty small bowels in experimental group were closed by the high-frequency welding device, and the other fifty small bowels in comparison group were hand-sutured. All the small bowels were subjected to leak pressure testing later on. The speed of closure and bursting pressure were compared. The 50 porcine small bowels closed by the high-frequency welding device showed a success rate of 100%. Compared with the hand-sutured group, the bursting pressures of the former were significantly lower (P<0.01) and the closing process was significantly shorter (P<0.01). The pathological changes of the closed ends mainly presented as acute thermal and pressure induced injury. Experimental results show that the high-frequency welding device has higher feasibility in closing the small bowel.

  15. High-cut characteristics of the baroreflex neural arc preserve baroreflex gain against pulsatile pressure.

    PubMed

    Kawada, Toru; Zheng, Can; Yanagiya, Yusuke; Uemura, Kazunori; Miyamoto, Tadayoshi; Inagaki, Masashi; Shishido, Toshiaki; Sugimachi, Masaru; Sunagawa, Kenji

    2002-03-01

    A transfer function from baroreceptor pressure input to sympathetic nerve activity (SNA) shows derivative characteristics in the frequency range below 0.8 Hz in rabbits. These derivative characteristics contribute to a quick and stable arterial pressure (AP) regulation. However, if the derivative characteristics hold up to heart rate frequency, the pulsatile pressure input will yield a markedly augmented SNA signal. Such a signal would saturate the baroreflex signal transduction, thereby disabling the baroreflex regulation of AP. We hypothesized that the transfer gain at heart rate frequency would be much smaller than that predicted from extrapolating the derivative characteristics. In anesthetized rabbits (n = 6), we estimated the neural arc transfer function in the frequency range up to 10 Hz. The transfer gain was lost at a rate of -20 dB/decade when the input frequency exceeded 0.8 Hz. A numerical simulation indicated that the high-cut characteristics above 0.8 Hz were effective to attenuate the pulsatile signal and preserve the open-loop gain when the baroreflex dynamic range was finite.

  16. Pressure effects on the dissipative behavior of nanocrystalline diamond microelectromechanical resonators

    NASA Astrophysics Data System (ADS)

    Santos, J. T.; Holz, T.; Fernandes, A. J. S.; Costa, F. M.; Chu, V.; Conde, J. P.

    2015-02-01

    Diamond-based microelectromechanical resonators have the potential of enhanced performance due to the chemical inertness of the diamond structural layer and its high Young’s modulus, high wear resistance, low thermal expansion coefficient, and very high thermal conductivity. In this work, the resonance frequency and quality factor of MEMS resonators based on nanocrystalline diamond films are characterized under different air pressures. The dynamic behavior of 50-300 μm long linear bridges and double ended tuning forks, with resonance frequencies between 0.5 and 15 MHz and quality factors as high as 50 000 are described as a function of measurement pressure from high vacuum(~10 mTorr) up to atmospheric conditions. The resonance frequencies and quality factors in vacuum show good agreement with the theoretical models including anchor and thermoelastic dissipation (TED). The Young’s moduli for nanocrystalline diamond films extrapolated from experimental data are between 840-920 GPa. The critical pressure values, at which the quality factor starts decreasing due to dissipation in air, are dependent on the resonator length. Longer structures, with quality factors limited by TED and lower resonance frequencies, have low critical pressures, of the order of 1-10 Torr and go from an intrinsic dissipation, to a molecular dissipation regime and finally to a region of viscous dissipation. Shorter resonators, with higher resonance frequencies and quality factors limited by anchor losses, have higher critical pressures, some higher than atmospheric pressure, and enter directly into the viscous dissipation regime from the intrinsic region.

  17. Short-term variability of blood pressure and heart rate in hyperthyroidism.

    PubMed

    Girard, A; Hugues, F C; Le Jeunne, C; Elghozi, J L

    1998-06-01

    The effect of hyperthyroidism on the short-term memory variability of blood pressure and heart rate was evaluated in 12 untreated hyperthyroid patients during thyrotoxicosis and after a 6 1/2 month treatment designed to achieve a stable euthyroid state. Beat-by-beat finger blood pressure was measured with a Finapres device. The pulse interval, from which pulse rate was derived, was obtained from the blood pressure signal. Due to the significant change in heart rhythm associated with thyrotoxicosis, both pulse interval (taken as a surrogate of heart period) and pulse rate (taken as a surrogate of heart rate) were computed. Power spectral analysis showed a reduction in the overall heart period variability in the supine position in the hyperthyroid compared to the euthyroid state. This effect was observed in the low-frequency (0.005-0.068 Hz), mid-frequency (0.068-0.127 Hz) and high-frequency (respiratory) domains as well, with a significant reduction of the modulus of these bands of 31%, 35% and 47%, respectively. The heart rate spectral modulus also exhibited a reduction of the high-frequency component (31%) in the supine position in the hyperthyroid subjects. These changes in heart rhythmicity corroborate a vagal deficit in hyperthyroidism. In addition, blood pressure spectral power exhibited a significant deficit in the orthostatism-induced mid-frequency systolic blood pressure rise in the hyperthyroid state (64%) compared with the euthyroid state. This observation may reflect a reduced vascular sympathetic activation with standing. The resulting vasodilatation could well contribute to normalize blood pressure in thyrotoxicosis in which cardiac output is increased.

  18. Effect of high-frequency near-infrared diode laser irradiation on periodontal tissues during experimental tooth movement in rats.

    PubMed

    Gunji, Hidemi; Kunimatsu, Ryo; Tsuka, Yuji; Yoshimi, Yuki; Sumi, Keisuke; Awada, Tetsuya; Nakajima, Kengo; Kimura, Aya; Hiraki, Tomoka; Hirose, Naoto; Yanoshita, Makoto; Tanimoto, Kotaro

    2018-02-05

    Tooth movement during orthodontic treatment is associated with bone neoplasticity and bone resorption on the tension and pressure sides. Previous clinical studies have suggested that low-power laser irradiation can accelerate tooth movement during orthodontic treatment, although the underlying mechanism remains unclear. In this study, we used a high-frequency near-infrared diode laser that generates less heat and examined the histologic changes in periodontal tissue during experimental tooth movement with laser irradiation. A nickel-titanium closed coil was mounted between the maxillary left side first molar and incisor of rats to model experimental tooth movement. The laser-irradiation and the control groups were set, and the amount of movement of the first molar on 7th and 14th days after the start of pulling of the first molar tooth on the maxillary left was measured by three-dimensional analysis of µCT. After tooth movement, tissue samples from the mesial and tension sides were collected, and successive horizontal sections were prepared and examined using hematoxylin-eosin and TRAP staining and immunohistochemical staining for RANKL, OPG, ALP, and proliferating cell nuclear antigen (PCNA). Changes in tissue temperature following laser irradiation were also examined. Laser irradiation significantly increased tooth movement compared with non-irradiated controls. Histologic staining of the pressure-side mesial root in laser-irradiated rats revealed enhanced RANKL expression and increased numbers of TRAP-positive cells compared with controls. By contrast, on the tension side, laser irradiation led to increased expression of ALP and PCNA. These data indicate that high-frequency near-infrared diode laser irradiation on the pressure side upregulates RANKL expression and accelerates osteoclast differentiation, facilitating bone resorption, whereas bone formation is induced on the tension side. This study demonstrates that high-frequency near-infrared diode laser irradiation of periodontal tissue leads to metabolic activation, which ultimately increases the rate of tooth movement. Lasers Surg. Med. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  19. Experimental Investigation of Cavitation Induced Feedline Instability from an Orifice

    NASA Technical Reports Server (NTRS)

    Hitt, Matthew A.; Lineberry, David M.; Ahuja, Vineet; Frederick, Robert A,

    2012-01-01

    This paper details the results of an experimental investigation into the cavitation instabilities created by a circular orifice conducted at the University of Alabama in Huntsville Propulsion Research Center. This experiment was conducted in concert with a computational simulation to serve as a reference point for the simulation. Testing was conducted using liquid nitrogen as a cryogenic propellant simulant. A 1.06 cm diameter thin orifice with a rounded inlet was tested in an approximately 1.25 kg/s flow with inlet pressures ranging from 504.1 kPa to 829.3 kPa. Pressure fluctuations generated by the orifice were measured using a high frequency pressure sensor located 0.64 tube diameters downstream of the orifice. Fast Fourier Transforms were performed on the high frequency data to determine the instability frequency. Shedding resulted in a primary frequency with a cavitation related subharmonic frequency. For this experiment, the cavitation instability ranged from 153 Hz to 275 Hz. Additionally, the strength of the cavitation occur red as a function of cavitation number. At lower cavitation numbers, the strength of the cavitation instability ranged from 2.4 % to 7 % of the inlet pressure. However, at higher cavitation numbers, the strength of the cavitation instability ranged from 0.6 % to 1 % of the inlet pressure.

  20. Fine structure of the low-frequency spectra of heart rate and blood pressure

    PubMed Central

    Kuusela, Tom A; Kaila, Timo J; Kähönen, Mika

    2003-01-01

    Background The aim of this study was to explore the principal frequency components of the heart rate and blood pressure variability in the low frequency (LF) and very low frequency (VLF) band. The spectral composition of the R–R interval (RRI) and systolic arterial blood pressure (SAP) in the frequency range below 0.15 Hz were carefully analyzed using three different spectral methods: Fast Fourier transform (FFT), Wigner-Ville distribution (WVD), and autoregression (AR). All spectral methods were used to create time–frequency plots to uncover the principal spectral components that are least dependent on time. The accurate frequencies of these components were calculated from the pole decomposition of the AR spectral density after determining the optimal model order – the most crucial factor when using this method – with the help of FFT and WVD methods. Results Spectral analysis of the RRI and SAP of 12 healthy subjects revealed that there are always at least three spectral components below 0.15 Hz. The three principal frequency components are 0.026 ± 0.003 (mean ± SD) Hz, 0.076 ± 0.012 Hz, and 0.117 ± 0.016 Hz. These principal components vary only slightly over time. FFT-based coherence and phase-function analysis suggests that the second and third components are related to the baroreflex control of blood pressure, since the phase difference between SAP and RRI was negative and almost constant, whereas the origin of the first component is different since no clear SAP–RRI phase relationship was found. Conclusion The above data indicate that spontaneous fluctuations in heart rate and blood pressure within the standard low-frequency range of 0.04–0.15 Hz typically occur at two frequency components rather than only at one as widely believed, and these components are not harmonically related. This new observation in humans can help explain divergent results in the literature concerning spontaneous low-frequency oscillations. It also raises methodological and computational questions regarding the usability and validity of the low-frequency spectral band when estimating sympathetic activity and baroreflex gain. PMID:14552660

  1. Fine structure of the low-frequency spectra of heart rate and blood pressure.

    PubMed

    Kuusela, Tom A; Kaila, Timo J; Kähönen, Mika

    2003-10-13

    The aim of this study was to explore the principal frequency components of the heart rate and blood pressure variability in the low frequency (LF) and very low frequency (VLF) band. The spectral composition of the R-R interval (RRI) and systolic arterial blood pressure (SAP) in the frequency range below 0.15 Hz were carefully analyzed using three different spectral methods: Fast Fourier transform (FFT), Wigner-Ville distribution (WVD), and autoregression (AR). All spectral methods were used to create time-frequency plots to uncover the principal spectral components that are least dependent on time. The accurate frequencies of these components were calculated from the pole decomposition of the AR spectral density after determining the optimal model order--the most crucial factor when using this method--with the help of FFT and WVD methods. Spectral analysis of the RRI and SAP of 12 healthy subjects revealed that there are always at least three spectral components below 0.15 Hz. The three principal frequency components are 0.026 +/- 0.003 (mean +/- SD) Hz, 0.076 +/- 0.012 Hz, and 0.117 +/- 0.016 Hz. These principal components vary only slightly over time. FFT-based coherence and phase-function analysis suggests that the second and third components are related to the baroreflex control of blood pressure, since the phase difference between SAP and RRI was negative and almost constant, whereas the origin of the first component is different since no clear SAP-RRI phase relationship was found. The above data indicate that spontaneous fluctuations in heart rate and blood pressure within the standard low-frequency range of 0.04-0.15 Hz typically occur at two frequency components rather than only at one as widely believed, and these components are not harmonically related. This new observation in humans can help explain divergent results in the literature concerning spontaneous low-frequency oscillations. It also raises methodological and computational questions regarding the usability and validity of the low-frequency spectral band when estimating sympathetic activity and baroreflex gain.

  2. Physical property measurements on analog granites related to the joint verification experiment

    NASA Astrophysics Data System (ADS)

    Martin, Randolph J., III; Coyner, Karl B.; Haupt, Robert W.

    1990-08-01

    A key element in JVE (Joint Verification Experiment) conducted jointly between the United States and the USSR is the analysis of the geology and physical properties of the rocks in the respective test sites. A study was initiated to examine unclassified crystalline rock specimens obtained from areas near the Soviet site, Semipalatinsk and appropriate analog samples selected from Mt. Katadin, Maine. These rocks were also compared to Sierra White and Westerly Granite which have been studied in great detail. Measurements performed to characterize these rocks were: (1) Uniaxial strain with simultaneous compressional and shear wave velocities; (2) Hydrostatic compression to 150 MPa with simultaneous compressional and shear wave velocities; (3) Attenuation measurements as a function of frequency and strain amplitude for both dry and water saturated conditions. Elastic moduli determined from the hydrostatic compression and uniaxial strain test show that the rock matrix/mineral properties were comparable in magnitudes which vary within 25 percent from sample to sample. These properties appear to be approximately isotropic, especially at high pressures. However, anisotropy evident for certain samples at pressures below 35 MPa is attributed to dominant pre-existing microcrack populations and their alignments. Dependence of extensional attenuation and Young's modulus on strain amplitude were experimentally determined for intact Sierra White granite using the hysteresis loop technique.

  3. Design of air blast pressure sensors based on miniature silicon membrane and piezoresistive gauges

    NASA Astrophysics Data System (ADS)

    Riondet, J.; Coustou, A.; Aubert, H.; Pons, P.; Lavayssière, M.; Luc, J.; Lefrançois, A.

    2017-11-01

    Available commercial piezoelectric pressure sensors are not able to accurately reproduce the ultra-fast transient pressure occurring during an air blast experiment. In this communication a new pressure sensor prototype based on a miniature silicon membrane and piezoresistive gauges is reported for significantly improving the performances in terms of time response. Simulation results demonstrate the feasibility of a pressure transducer having a fundamental resonant frequency almost ten times greater than the commercial piezoelectric sensors one. The sensor uses a 5μm-thick SOI membrane and four P-type silicon gauges (doping level ≅ 1019 at/cm3) in Wheatstone bridge configuration. To obtain a good trade-off between the fundamental mechanical resonant frequency and pressure sensitivity values, the typical dimension of the rectangular membrane is fixed to 30μm x 90μm with gauge dimension of 1μm x 5μm. The achieved simulated mechanical resonant frequency of these configuration is greater than 40MHz with a sensitivity of 0.04% per bar.

  4. Glottal flow through a two-mass model: comparison of Navier-Stokes solutions with simplified models.

    PubMed

    de Vries, M P; Schutte, H K; Veldman, A E P; Verkerke, G J

    2002-04-01

    A new numerical model of the vocal folds is presented based on the well-known two-mass models of the vocal folds. The two-mass model is coupled to a model of glottal airflow based on the incompressible Navier-Stokes equations. Glottal waves are produced using different initial glottal gaps and different subglottal pressures. Fundamental frequency, glottal peak flow, and closed phase of the glottal waves have been compared with values known from the literature. The phonation threshold pressure was determined for different initial glottal gaps. The phonation threshold pressure obtained using the flow model with Navier-Stokes equations corresponds better to values determined in normal phonation than the phonation threshold pressure obtained using the flow model based on the Bernoulli equation. Using the Navier-Stokes equations, an increase of the subglottal pressure causes the fundamental frequency and the glottal peak flow to increase, whereas the fundamental frequency in the Bernoulli-based model does not change with increasing pressure.

  5. High-performance coaxial EPR cavity for investigations at elevated temperatures and pressures

    NASA Astrophysics Data System (ADS)

    Goldberg, Ira B.; McKinney, Ted M.

    1984-07-01

    A microwave cavity suitable for heating a sample to temperatures above 800 °C within 15 s at gas pressures above 17.5 MPa is reported. The cavity is coaxial and operates in the TE011 mode at frequencies between 9 and 10 GHz. The heating element is constructed of nickel-chromium (i.e., Chromel) wire. It consists of two concentric helices wound in opposite senses (directions) and connected in series so as to minimize the magnetic field generated by the heater current. The heater is potted in magnesium oxide-phosphate ceramic and placed inside of a cylinder made from 50-μm copper foil which provides uniform temperature distribution and shields the heater from the microwave field. This assembly then serves as the heating element and the coaxial conductor of the cavity. The diameter of the coaxial heater assembly is approximately 7 mm. The sample is confined by a cylindrical quartz cuvette which surrounds the coaxial conductor. Sample thicknesses of 0.2 to 1.0 mm can be used. Heating from room temperature to 800 °C requires between 15 and 20 s. Operating pressures up to 17 MPa have been used, although the structural design limit of the brass or beryllium copper walls is greater than 22 MPa. Modulation coils are placed in recessed areas of the cavity walls and covered with a thin layer of copper. Cooling water flows through channels cut into the walls to maintain constant microwave parameters. Q factors of 8000 -12 000 can be obtained depending on the sample.

  6. The Breathing Snowpack: Pressure-induced Vapor Flux of Temperate Snow

    NASA Astrophysics Data System (ADS)

    Drake, S. A.; Selker, J. S.; Higgins, C. W.

    2017-12-01

    As surface air pressure increases, hydrostatic compression of the air column forces atmospheric air into snowpack pore space. Likewise, as surface air pressure decreases, the atmospheric air column decompresses and saturated air exits the snow. Alternating influx and efflux of air can be thought of as a "breathing" process that produces an upward vapor flux when air above the snow is not saturated. The impact of pressure-induced vapor exchange is assumed to be small and is thus ignored in model parameterizations of surface processes over snow. Rationale for disregarding this process is that large amplitude pressure changes as caused by synoptic weather patterns are too infrequent to credibly impact vapor flux. The amplitude of high frequency pressure changes is assumed to be too small to affect vapor flux, however, the basis for this hypothesis relies on pressure measurements collected over an agricultural field (rather than snow). Resolution of the impact of pressure changes on vapor flux over seasonal cycles depends on an accurate representation of the magnitude of pressure changes caused by changes in wind as a function of the frequency of pressure changes. High precision in situ pressure measurements in a temperature snowpack allowed us to compute the spectra of pressure changes vs. wind forcing. Using a simplified model for vapor exchange we then computed the frequency of pressure changes that maximize vapor exchange. We examine and evaluate the seasonal impact of pressure-induced vapor exchange relative to other snow ablation processes.

  7. Low-frequency dynamics of pressure-induced turbulent separation bubbles

    NASA Astrophysics Data System (ADS)

    Weiss, Julien; Mohammed-Taifour, Abdelouahab; Lefloch, Arnaud

    2017-11-01

    We experimentally investigate a pressure-induced turbulent separation bubble (TSB), which is generated on a flat test surface through a combination of adverse and favorable pressure gradients imposed on a nominally two-dimensional, incompressible, turbulent boundary layer. We probe the flow using piezo-resistive pressure transducers, MEMS shear-stress sensors, and high-speed, 2D-2C, PIV measurements. Through the use of Fourier analysis of the wall-pressure fluctuations and Proper Orthogonal Decomposition of the velocity fields, we show that this type of flow is characterized by a self-induced, low-frequency contraction and expansion - called breathing - of the TSB. The dominant Strouhal number of this motion, based on the TSB length and the incoming velocity in the potential flow, is of the order of 0.01. We compare this motion to the low-frequency dynamics observed in laminar separation bubbles (LSBs), geometry-induced TSBs, and shock-induced separated flows.

  8. Moderate pressure massage elicits a parasympathetic nervous system response.

    PubMed

    Diego, Miguel A; Field, Tiffany

    2009-01-01

    Twenty healthy adults were randomly assigned to a moderate pressure or a light pressure massage therapy group, and EKGs were recorded during a 3-min baseline, during the 15-min massage period and during a 3-min postmassage period. EKG data were then used to derive the high frequency (HF), low frequency (LF) components of heart rate variability and the low to high frequency ratio (LF/HF) as noninvasive markers of autonomic nervous system activity. The participants who received the moderate pressure massage exhibited a parasympathetic nervous system response characterized by an increase in HF, suggesting increased vagal efferent activity and a decrease in the LF/HF ratio, suggesting a shift from sympathetic to parasympathetic activity that peaked during the first half of the massage period. On the other hand, those who received the light pressure massage exhibited a sympathetic nervous system response characterized by decreased HF and increased LF/HF.

  9. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.

    2011-04-26

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersectionmore » geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.« less

  10. Echo planar imaging at 4 Tesla with minimum acoustic noise.

    PubMed

    Tomasi, Dardo G; Ernst, Thomas

    2003-07-01

    To minimize the acoustic sound pressure levels of single-shot echo planar imaging (EPI) acquisitions on high magnetic field MRI scanners. The resonance frequencies of gradient coil vibrations, which depend on the coil length and the elastic properties of the materials in the coil assembly, were measured using piezoelectric transducers. The frequency of the EPI-readout train was adjusted to avoid the frequency ranges of mechanical resonances. Our MRI system exhibited two sharp mechanical resonances (at 720 and 1220 Hz) that can increase vibrational amplitudes up to six-fold. A small adjustment of the EPI-readout frequency made it possible to reduce the sound pressure level of EPI-based perfusion and functional MRI scans by 12 dB. Normal vibrational modes of MRI gradient coils can dramatically increase the sound pressure levels during echo planar imaging (EPI) scans. To minimize acoustic noise, the frequency of EPI-readout trains and the resonance frequencies of gradient coil vibrations need to be different. Copyright 2003 Wiley-Liss, Inc.

  11. Flutter of High-Speed Civil Transport Flexible Semispan Model: Time-Frequency Analysis

    NASA Technical Reports Server (NTRS)

    Chabalko, Christopher C.; Hajj, Muhammad R.; Silva, Walter A.

    2006-01-01

    Time/frequency analysis of fluctuations measured by pressure taps and strain gauges in the experimental studies of the flexible semispan model of a high-speed civil transport wing configuration is performed. The interest is in determining the coupling between the aerodynamic loads and structural motions that led to the hard flutter conditions and loss of the model. The results show that, away from the hard flutter point, the aerodynamic loads at all pressure taps near the wing tip and the structural motions contained the same frequency components. On the other hand, in the flow conditions leading to the hard flutter, the frequency content of the pressure fluctuations near the leading and trailing edges varied significantly. This led to contribution to the structural motions over two frequency ranges. The ratio of these ranges was near 2:1, which suggests the possibility of nonlinear structural coupling.

  12. Blade pressure measurements

    NASA Astrophysics Data System (ADS)

    Chivers, J. W. H.

    Three measurement techniques which enable rotating pressures to be measured during the normal operation of a gas turbine or a component test rig are described. The first technique was developed specifically to provide steady and transient blade surface pressure data to aid both fan flutter research and general fan performance development. This technique involves the insertion of miniature high frequency response pressure transducers into the fan blades of a large civil gas turbine. The other two techniques were developed to measure steady rotating pressures inside and on the surface of engine or rig turbine blades and also rotating pressures in cooling feed systems. These two low frequency response systems are known as the "pressure pineapple' (a name which resulted from the shape of the original prototype) and the rotating scanivalve.

  13. Lithium monosilicide (LiSi), a low-dimensional silicon-based material prepared by high pressure synthesis: NMR and vibrational spectroscopy and electrical properties characterization

    NASA Astrophysics Data System (ADS)

    Stearns, Linda A.; Gryko, Jan; Diefenbacher, Jason; Ramachandran, Ganesh K.; McMillan, Paul F.

    2003-06-01

    Lithium monosilicide (LiSi) was formed at high pressures and high temperatures (1.0-2.5 GPa and 500-700°C) in a piston-cylinder apparatus. This compound was previously shown to have an unusual structure based on 3-fold coordinated silicon atoms arranged into interpenetrating sheets. In the present investigation, lowered synthesis pressures permitted recovery of large (150-200 mg) quantities of sample for structural studies via NMR spectroscopy ( 29Si and 7Li), Raman spectroscopy and electrical conductivity measurements. The 29Si chemical shift occurs at -106.5 ppm, intermediate between SiH 4 and Si(Si(CH 3) 3) 4, but lies off the trend established by the other alkali monosilicides (NaSi, KSi, RbSi, CsSi), that contain isolated Si 44- anions. Raman spectra show a strong peak at 508 cm -1 due to symmetric Si-Si stretching vibrations, at lower frequency than for tetrahedrally coordinated Si frameworks, due to the longer Si-Si bonds in the 3-coordinated silicide. Higher frequency vibrations occur due to asymmetric stretching. Electrical conductivity measurements indicate LiSi is a narrow-gap semiconductor ( Eb˜0.057 eV). There is a rapid increase in conductivity above T=450 K, that might be due to the onset of Li + mobility.

  14. Experimental study on the regenerator under actual operating conditions

    NASA Astrophysics Data System (ADS)

    Nam, Kwanwoo; Jeong, Sangkwon

    2002-05-01

    An experimental apparatus was prepared to investigate thermal and hydrodynamic characteristics of the regenerator under its actual operating conditions. The apparatus included a compressor to pressurize and depressurize regenerator with various operating frequencies. Cold end of the regenerator was maintained around 100 K by means of liquid nitrogen container and heat exchanger. Instantaneous gas temperature and mass flow rate were measured at both ends of the regenerator during the whole pressure cycle. Pulsating pressure and pressure drop across the regenerator were also measured. The operating frequency of the pressure cycle was varied between 3 and 60 Hz, which are typical operating frequencies of Gifford-McMahon, pulse tube, and Stirling cryocoolers. First, friction factor for the wire screen mesh was directly determined from room temperature experiments. When the operating frequency was less than 9 Hz, the oscillating flow friction factor was nearly same as the steady flow friction factor for Reynolds number up to 100. For 60 Hz operations, the ratio of oscillating flow friction factor to steady flow one was increased as hydraulic Reynolds number became high. When the Reynolds number was 100, this ratio was about 1.6. Second, ineffectiveness of the regenerator was obtained when the cold-end was maintained around 100 K and the warm-end at 300 K to simulate the actual operating condition of the regenerator in cryocooler. Effect of the operating frequency on ineffectiveness of regenerator was discussed at low frequency range.

  15. Hybrid simulation of fishbone instabilities in the EAST tokamak

    DOE PAGES

    Shen, Wei; Wang, Feng; Fu, G. Y.; ...

    2017-08-11

    Hybrid simulations with the global kinetic-magnetohydrodynamic (MHD) code M3D-K have been carried out to investigate the linear stability and nonlinear dynamics of beam-driven fishbone in the experimental advanced superconducting tokamak (EAST) experiment. Linear simulations show that a low frequency fishbone instability is excited at experimental value of beam ion pressure. The mode is mainly driven by low energy beam ions via precessional resonance. Our results are consistent with the experimental measurement with respect to mode frequency and mode structure. When the beam ion pressure is increased to exceed a critical value, the low frequency mode transits to a beta-induced Alfvenmore » eigenmode (BAE) with much higher frequency. This BAE is driven by higher energy beam ions. Nonlinear simulations show that the frequency of the low frequency fishbone chirps up and down with corresponding hole-clump structures in phase space, consistent with the Berk-Breizman theory. In addition to the low frequency mode, the high frequency BAE is excited during the nonlinear evolution. Furthermore, for the transient case of beam pressure fraction where the low and high frequency modes are simultaneously excited in the linear phase, only one dominant mode appears in the nonlinear phase with frequency jumps up and down during nonlinear evolution.« less

  16. Radiation pressure excitation of Low Temperature Atomic Force & Magnetic Force Microscope (LT-AFM/MFM) for Imaging

    NASA Astrophysics Data System (ADS)

    Karci, Ozgur; Celik, Umit; Oral, Ahmet; NanoMagnetics Instruments Ltd. Team; Middle East Tech Univ Team

    2015-03-01

    We describe a novel method for excitation of Atomic Force Microscope (AFM) cantilevers by means of radiation pressure for imaging in an AFM for the first time. Piezo excitation is the most common method for cantilever excitation, but it may cause spurious resonance peaks. A fiber optic interferometer with 1310 nm laser was used both to measure the deflection of cantilever and apply a force to the cantilever in a LT-AFM/MFM from NanoMagnetics Instruments. The laser power was modulated at the cantilever`s resonance frequency by a digital Phase Lock Loop (PLL). The force exerted by the radiation pressure on a perfectly reflecting surface by a laser beam of power P is F = 2P/c. We typically modulate the laser beam by ~ 800 μW and obtain 10nm oscillation amplitude with Q ~ 8,000 at 2.5x10-4 mbar. The cantilever's stiffness can be accurately calibrated by using the radiation pressure. We have demonstrated performance of the radiation pressure excitation in AFM/MFM by imaging a hard disk sample between 4-300K and Abrikosov vortex lattice in BSCCO single crystal at 4K to for the first time.

  17. External and middle ear sound pressure distribution and acoustic coupling to the tympanic membrane

    PubMed Central

    Bergevin, Christopher; Olson, Elizabeth S.

    2014-01-01

    Sound energy is conveyed to the inner ear by the diaphanous, cone-shaped tympanic membrane (TM). The TM moves in a complex manner and transmits sound signals to the inner ear with high fidelity, pressure gain, and a short delay. Miniaturized sensors allowing high spatial resolution in small spaces and sensitivity to high frequencies were used to explore how pressure drives the TM. Salient findings are: (1) A substantial pressure drop exists across the TM, and varies in frequency from ∼10 to 30 dB. It thus appears reasonable to approximate the drive to the TM as being defined solely by the pressure in the ear canal (EC) close to the TM. (2) Within the middle ear cavity (MEC), spatial variations in sound pressure could vary by more than 20 dB, and the MEC pressure at certain locations/frequencies was as large as in the EC. (3) Spatial variations in pressure along the TM surface on the EC-side were typically less than 5 dB up to 50 kHz. Larger surface variations were observed on the MEC-side. PMID:24606269

  18. Numerical Study of Pressure Fluctuations due to a Mach 6 Turbulent Boundary Layer

    NASA Technical Reports Server (NTRS)

    Duan, Lian; Choudhari, Meelan M.

    2013-01-01

    Direct numerical simulations (DNS) are used to examine the pressure fluctuations generated by a Mach 6 turbulent boundary layer with nominal freestream Mach number of 6 and Reynolds number of Re(sub t) approx. =. 464. The emphasis is on comparing the primarily vortical pressure signal at the wall with the acoustic freestream signal under higher Mach number conditions. Moreover, the Mach-number dependence of pressure signals is demonstrated by comparing the current results with those of a supersonic boundary layer at Mach 2.5 and Re(sub t) approx. = 510. It is found that the freestream pressure intensity exhibits a strong Mach number dependence, irrespective of whether it is normalized by the mean wall shear stress or by the mean pressure, with the normalized fluctuation amplitude being significantly larger for the Mach 6 case. Spectral analysis shows that both the wall and freestream pressure fluctuations of the Mach 6 boundary layer have enhanced energy content at high frequencies, with the peak of the premultiplied frequency spectrum of freestream pressure fluctuations being at a frequency of omega(delta)/U(sub infinity) approx. = 3.1, which is more than twice the corresponding frequency in the Mach 2.5 case. The space-time correlations indicate that the pressure-carrying eddies for the higher Mach number case are of smaller size, less elongated in the spanwise direction, and convect with higher convection speeds relative to the Mach 2.5 case. The demonstrated Mach-number dependence of the pressure field, including radiation intensity, directionality, and convection speed, is consistent with the trend exhibited in experimental data and can be qualitatively explained by the notion of "eddy Mach wave" radiation.

  19. Phase Aberration and Attenuation Effects on Acoustic Radiation Force-Based Shear Wave Generation.

    PubMed

    Carrascal, Carolina Amador; Aristizabal, Sara; Greenleaf, James F; Urban, Matthew W

    2016-02-01

    Elasticity is measured by shear wave elasticity imaging (SWEI) methods using acoustic radiation force to create the shear waves. Phase aberration and tissue attenuation can hamper the generation of shear waves for in vivo applications. In this study, the effects of phase aberration and attenuation in ultrasound focusing for creating shear waves were explored. This includes the effects of phase shifts and amplitude attenuation on shear wave characteristics such as shear wave amplitude, shear wave speed, shear wave center frequency, and bandwidth. Two samples of swine belly tissue were used to create phase aberration and attenuation experimentally. To explore the phase aberration and attenuation effects individually, tissue experiments were complemented with ultrasound beam simulations using fast object-oriented C++ ultrasound simulator (FOCUS) and shear wave simulations using finite-element-model (FEM) analysis. The ultrasound frequency used to generate shear waves was varied from 3.0 to 4.5 MHz. Results: The measured acoustic pressure and resulting shear wave amplitude decreased approximately 40%-90% with the introduction of the tissue samples. Acoustic intensity and shear wave displacement were correlated for both tissue samples, and the resulting Pearson's correlation coefficients were 0.99 and 0.97. Analysis of shear wave generation with tissue samples (phase aberration and attenuation case), measured phase screen, (only phase aberration case), and FOCUS/FEM model (only attenuation case) showed that tissue attenuation affected the shear wave generation more than tissue aberration. Decreasing the ultrasound frequency helped maintain a focused beam for creation of shear waves in the presence of both phase aberration and attenuation.

  20. Systems and methods of monitoring acoustic pressure to detect a flame condition in a gas turbine

    DOEpatents

    Ziminsky, Willy Steve [Simpsonville, SC; Krull, Anthony Wayne [Anderson, SC; Healy, Timothy Andrew , Yilmaz, Ertan

    2011-05-17

    A method may detect a flashback condition in a fuel nozzle of a combustor. The method may include obtaining a current acoustic pressure signal from the combustor, analyzing the current acoustic pressure signal to determine current operating frequency information for the combustor, and indicating that the flashback condition exists based at least in part on the current operating frequency information.

  1. Development of a Facility for Combustion Stability Experiments at Supercritical Pressure

    DTIC Science & Technology

    2013-12-01

    by the exhaust orifice. This technique adds freedom for designing a large array experimental conditions, because chamber pressure is controlled...analytical examination reveals a broad array of frequencies. The analytical relationship between chamber length L, acoustic frequency fF, and the speed...the pressure amplitude is directly controlled by altering the voltage input to the sirens, similar to a traditional loudspeaker . Last, both a PN and

  2. Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones

    NASA Astrophysics Data System (ADS)

    Nakajima, Hideko Heidi; Dong, Wei; Olson, Elizabeth S.; Merchant, Saumil N.; Ravicz, Michael E.; Rosowski, John J.

    2009-02-01

    We present the first simultaneous sound pressure measurements in scala vestibuli and scala tympani of the cochlea in human cadaveric temporal bones. Micro-scale fiberoptic pressure sensors enabled the study of differential sound pressure at the cochlear base. This differential pressure is the input to the cochlear partition, driving cochlear waves and auditory transduction. Results showed that: pressure of scala vestibuli was much greater than scala tympani except at low and high frequencies where scala tympani pressure affects the input to the cochlea; the differential pressure proved to be an excellent measure of normal ossicular transduction of sound (shown to decrease 30-50 dB with ossicular disarticulation, whereas the individual scala pressures were significantly affected by non-ossicular conduction of sound at high frequencies); the middle-ear gain and differential pressure were generally bandpass in frequency dependence; and the middle-ear delay in the human was over twice that of the gerbil. Concurrent stapes velocity measurements allowed determination of the differential impedance across the partition and round-window impedance. The differential impedance was generally resistive, while the round-window impedance was consistent with a compliance in conjunction with distributed inertia and damping. Our techniques can be used to study inner-ear conductive pathologies (e.g., semicircular dehiscence), as well as non-ossicular cochlear stimulation (e.g., round-window stimulation) - situations that cannot be completely quantified by measurements of stapes velocity or scala-vestibuli pressure by themselves.

  3. Microcrack Quantification in Composite Materials by a Neural Network Analysis of Ultrasound Spectral Data

    NASA Technical Reports Server (NTRS)

    Walker, James L.; Russell, Samuel S.; Suits, Michael W.

    2003-01-01

    Intra-ply microcracking in unlined composite pressure vessels can be very troublesome to detect and when linked through the thickness can provide leak paths that may hinder mission success. The leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping into air pockets within the laminate. Ultrasonic techniques have been shown capable of detecting the presence of microcracking and in this work they are used to quantify the level of microcracking. Resonance ultrasound methods are utilized with artificial neural networks to build a microcrack prediction/measurement tool. Two networks are presented, one unsupervised to provide a qualitative measure of microcracking and one supervised which provides a quantitative assessment of the level of microcracking. The resonant ultrasound spectroscopic method is made sensitive to microcracking by tuning the input spectrum to the higher frequency (shorter wavelength) components allowing more significant interaction with the defects. This interaction causes the spectral characteristics to shift toward lower amplitudes at the higher frequencies. As the density of the defects increases more interactions occur and more drastic amplitude changes are observed. Preliminary experiments to quantify the level of microcracking induced in graphite/epoxy composite samples through a combination of tensile loading and cryogenic temperatures are presented. Both unsupervised (Kohonen) and supervised (radial basis function) artificial neural networks are presented to determine the measurable effect on the resonance spectrum of the ultrasonic data taken from the samples.

  4. High pressure gas laser technology for atmospheric remote sensing

    NASA Technical Reports Server (NTRS)

    Javan, A.

    1980-01-01

    The development of a fixed frequency chirp-free and highly stable intense pulsed laser made for Doppler wind velocity measurements with accurate ranging is described. Energy extraction from a high pressure CO2 laser at a tunable single mode frequency is also examined.

  5. Spectral indices of cardiovascular adaptations to short-term simulated microgravity exposure

    NASA Technical Reports Server (NTRS)

    Patwardhan, A. R.; Evans, J. M.; Berk, M.; Grande, K. J.; Charles, J. B.; Knapp, C. F.

    1995-01-01

    We investigated the effects of exposure to microgravity on the baseline autonomic balance in cardiovascular regulation using spectral analysis of cardiovascular variables measured during supine rest. Heart rate, arterial pressure, radial flow, thoracic fluid impedance and central venous pressure were recorded from nine volunteers before and after simulated microgravity, produced by 20 hours of 6 degrees head down bedrest plus furosemide. Spectral powers increased after simulated microgravity in the low frequency region (centered at about 0.03 Hz) in arterial pressure, heart rate and radial flow, and decreased in the respiratory frequency region (centered at about 0.25 Hz) in heart rate. Reduced heart rate power in the respiratory frequency region indicates reduced parasympathetic influence on the heart. A concurrent increase in the low frequency power in arterial pressure, heart rate, and radial flow indicates increased sympathetic influence. These results suggest that the baseline autonomic balance in cardiovascular regulation is shifted towards increased sympathetic and decreased parasympathetic influence after exposure to short-term simulated microgravity.

  6. Raman Frequencies Calculated from the Volume Data as a Function of Temperature at High Pressures for the Disordered Phase II of NH4I

    NASA Astrophysics Data System (ADS)

    Yurtseven, H.; Kavruk, D.

    In this study, we calculate the Raman frequencies as a function of temperature for the fixed pressures of 706, 1080 and 6355 bars using the volume data for phase II of ammonium iodide. The Raman frequencies calculated here are for the translational optic ν5 TOM (125 cm-1) lattice mode that is located at the zone boundary (M point) of the Brillouin zone of phase II for NH4I. For this calculation the volume data obtained at zero pressure, is used through the mode Grüneisen parameter for the disordered phase II (β phase) which has the CsCl structure of NH4I. Our predicted frequencies of the ν5 TOM (125 cm-1) mode can be compared when the Raman data for this lattice mode is available at various temperatures for fixed pressures of 706, 1080 and 6355 bars in the disordered phase II of ammonium iodide.

  7. Oxygen measurements at high pressures with vertical cavity surface-emitting lasers

    NASA Astrophysics Data System (ADS)

    Wang, J.; Sanders, S. T.; Jeffries, J. B.; Hanson, R. K.

    Measurements of oxygen concentration at high pressures (to 10.9 bar) were made using diode-laser absorption of oxygen A-band transitions near 760 nm. The wide current-tuning frequency range (>30 cm-1) of vertical cavity surface-emitting lasers (VCSELs) was exploited to enable the first scanned-wavelength demonstration of diode-laser absorption at high pressures; this strategy is more robust than fixed-wavelength strategies, particularly in hostile environments. The wide tuning range and rapid frequency response of the current tuning were further exploited to demonstrate wavelength-modulation absorption spectroscopy in a high-pressure environment. The minimum detectable absorbance demonstrated, 1×10-4, corresponds to 800 ppm-m oxygen detectivity at room temperature and is limited by etalon noise. The rapid- and wide-frequency tunability of VCSELs should significantly expand the application domain of absorption-based sensors limited in the past by the small current-tuning frequency range (typically <2 cm-1) of conventional edge-emitting diode lasers.

  8. Disinfection of S. mutans Bacteria Using a Plasma Needle at Atmospheric Pressure

    NASA Astrophysics Data System (ADS)

    Hansen, S.; Goree, J.; Liu, Bin; Drake, D.

    2007-11-01

    The plasma needle device produces a millimeter-size low-power glow discharge at atmospheric-pressure. It is intended for dental or medical applications. Radio-frequency high voltage is applied to a single needle electrode located inside a concentric gas-flow nozzle. A low-speed helium plasma jet flows out of the nozzle and mixes with ambient air. The jet is impinges on a surface that is to be treated, which in our test was a suspension of S. mutans bacteria that was plated onto the surface of agar nutrient in a Petri dish. S. mutans is the most important microorganism for causing dental caries. Imaging the sample after plasma treatment and incubation reveal the conditions where bacteria are killed, and the size of the treated spot.

  9. Low-frequency blood pressure oscillations and inotrope treatment failure in premature infants.

    PubMed

    Vesoulis, Zachary A; Hao, Jessica; McPherson, Christopher; El Ters, Nathalie M; Mathur, Amit M

    2017-07-01

    The underlying mechanism as to why some hypotensive preterm infants do not respond to inotropic medications remains unclear. For these infants, we hypothesize that impaired vasomotor function is a significant factor and is manifested through a decrease in low-frequency blood pressure variability across regulatory components of vascular tone. Infants born ≤28 wk estimated gestational age underwent prospective recording of mean arterial blood pressure for 72 h after birth. After error correction, root-mean-square spectral power was calculated for each valid 10-min data frame across each of four frequency bands ( B1 , 0.005-0.0095 Hz; B2 , 0.0095-0.02 Hz; B3 , 0.02-0.06 Hz; and B4 , 0.06-0.16) corresponding to different components of vasomotion control. Forty infants (twenty-nine normotensive control and eleven inotrope-exposed) were included with a mean ± SD estimated gestational age of 25.2 ± 1.6 wk and birth weight 790 ± 211 g. 9.7/11.8 Million (82%) data points were error-free and used for analysis. Spectral power across all frequency bands increased with time, although the magnitude was 20% less in the inotrope-exposed infants. A statistically significant increase in spectral power in response to inotrope initiation was noted across all frequency bands. Infants with robust blood pressure response to inotropes had a greater increase compared with those who had limited or no blood pressure response. In this study, hypotensive infants who require inotropes have decreased low-frequency variability at baseline compared with normotensive infants, which increases after inotrope initiation. Low-frequency spectral power does not change for those with inotrope treatment failure, suggesting dysfunctional regulation of vascular tone as a potential mechanism of treatment failure. NEW & NOTEWORTHY In this study, we examine patterns of low-frequency oscillations in blood pressure variability across regulatory components of vascular tone in normotensive and hypotensive infants exposed to inotropic medications. We found that hypotensive infants who require inotropes have decreased low-frequency variability at baseline, which increases after inotrope initiation. Low-frequency spectral power does not change for those with inotrope treatment failure, suggesting dysfunctional regulation of vascular tone as a potential mechanism of treatment failure. Copyright © 2017 the American Physiological Society.

  10. Infra-sound cancellation and mitigation in wind turbines

    NASA Astrophysics Data System (ADS)

    Boretti, Albert; Ordys, Andrew; Al Zubaidy, Sarim

    2018-03-01

    The infra-sound spectra recorded inside homes located even several kilometres far from wind turbine installations is characterized by large pressure fluctuation in the low frequency range. There is a significant body of literature suggesting inaudible sounds at low frequency are sensed by humans and affect the wellbeing through different mechanisms. These mechanisms include amplitude modulation of heard sounds, stimulating subconscious pathways, causing endolymphatic hydrops, and possibly potentiating noise-induced hearing loss. We suggest the study of infra-sound active cancellation and mitigation to address the low frequency noise issues. Loudspeakers generate pressure wave components of same amplitude and frequency but opposite phase of the recorded infra sound. They also produce pressure wave components within the audible range reducing the perception of the infra-sound to minimize the sensing of the residual infra sound.

  11. Application of an ultrasonic focusing radiator for acoustic levitation of submillimeter samples

    NASA Technical Reports Server (NTRS)

    Lee, M. C.

    1981-01-01

    An acoustic apparatus has been specifically developed to handle samples of submillimeter size in a gaseous medium. This apparatus consists of an acoustic levitation device, deployment devices for small liquid and solid samples, heat sources for sample heat treatment, acoustic alignment devices, a cooling system and data-acquisition instrumentation. The levitation device includes a spherical aluminum dish of 12 in. diameter and 0.6 in. thickness, 130 pieces of PZT transducers attached to the back side of the dish and a spherical concave reflector situated in the vicinity of the center of curvature of the dish. The three lowest operating frequencies for the focusing-radiator levitation device are 75, 105 and 163 kHz, respectively. In comparison with other levitation apparatus, it possesses a large radiation pressure and a high lateral positional stability. This apparatus can be used most advantageously in the study of droplets and spherical shell systems, for instance, for fusion target applications.

  12. Performance Characteristics of a New Generation Pressure Microsensor for Physiologic Applications

    PubMed Central

    Cottler, Patrick S.; Karpen, Whitney R.; Morrow, Duane A.; Kaufman, Kenton R.

    2009-01-01

    A next generation fiber-optic microsensor based on the extrinsic Fabry–Perot interferometric (EFPI) technique has been developed for pressure measurements. The basic physics governing the operation of these sensors makes them relatively tolerant or immune to the effects of high-temperature, high-EMI, and highly-corrosive environments. This pressure microsensor represents a significant improvement in size and performance over previous generation sensors. To achieve the desired overall size and sensitivity, numerical modeling of diaphragm deflection was incorporated in the design, with the desired dimensions and calculated material properties. With an outer diameter of approximately 250 µm, a dynamic operating range of over 250 mmHg, and a sampling frequency of 960 Hz, this sensor is ideal for the minimally invasive measurement of physiologic pressures and incorporation in catheter-based instrumentation. Nine individual sensors were calibrated and characterized by comparing the output to a U.S. National Institute of Standards and Technology (NIST) Traceable reference pressure over the range of 0–250 mmHg. The microsensor performance demonstrated accuracy of better than 2% full-scale output, and repeatability, and hysteresis of better than 1% full-scale output. Additionally, fatigue effects on five additional sensors were 0.25% full-scale output after over 10,000 pressure cycles. PMID:19495983

  13. Transfer function analysis of dynamic cerebral autoregulation in humans

    NASA Technical Reports Server (NTRS)

    Zhang, R.; Zuckerman, J. H.; Giller, C. A.; Levine, B. D.; Blomqvist, C. G. (Principal Investigator)

    1998-01-01

    To test the hypothesis that spontaneous changes in cerebral blood flow are primarily induced by changes in arterial pressure and that cerebral autoregulation is a frequency-dependent phenomenon, we measured mean arterial pressure in the finger and mean blood flow velocity in the middle cerebral artery (VMCA) during supine rest and acute hypotension induced by thigh cuff deflation in 10 healthy subjects. Transfer function gain, phase, and coherence function between changes in arterial pressure and VMCA were estimated using the Welch method. The impulse response function, calculated as the inverse Fourier transform of this transfer function, enabled the calculation of transient changes in VMCA during acute hypotension, which was compared with the directly measured change in VMCA during thigh cuff deflation. Beat-to-beat changes in VMCA occurred simultaneously with changes in arterial pressure, and the autospectrum of VMCA showed characteristics similar to arterial pressure. Transfer gain increased substantially with increasing frequency from 0.07 to 0.20 Hz in association with a gradual decrease in phase. The coherence function was > 0.5 in the frequency range of 0.07-0.30 Hz and < 0.5 at < 0.07 Hz. Furthermore, the predicted change in VMCA was similar to the measured VMCA during thigh cuff deflation. These data suggest that spontaneous changes in VMCA that occur at the frequency range of 0.07-0.30 Hz are related strongly to changes in arterial pressure and, furthermore, that short-term regulation of cerebral blood flow in response to changes in arterial pressure can be modeled by a transfer function with the quality of a high-pass filter in the frequency range of 0.07-0.30 Hz.

  14. Classification of the nonlinear dynamics and bifurcation structure of ultrasound contrast agents excited at higher multiples of their resonance frequency

    NASA Astrophysics Data System (ADS)

    Sojahrood, Amin Jafari; Kolios, Michael C.

    2012-07-01

    Through numerical simulation of the Hoff model we show that when ultrasound contrast agents (UCAs) are excited at frequencies which are close to integer (m>2) multiples of their natural resonance frequency, the bifurcation structure of the UCA oscillations as a function of pressure may be characterized by 3 general distinct regions. The UCA behavior starts with initial period one oscillations which undergoes a saddle node bifurcation to m coexisting attractors for an acoustic pressure above a threshold, P. Further increasing the pressure above a second threshold P, is followed by a sudden transition to period 1 oscillations.

  15. Bubble dynamics in a standing sound field: the bubble habitat.

    PubMed

    Koch, P; Kurz, T; Parlitz, U; Lauterborn, W

    2011-11-01

    Bubble dynamics is investigated numerically with special emphasis on the static pressure and the positional stability of the bubble in a standing sound field. The bubble habitat, made up of not dissolving, positionally and spherically stable bubbles, is calculated in the parameter space of the bubble radius at rest and sound pressure amplitude for different sound field frequencies, static pressures, and gas concentrations of the liquid. The bubble habitat grows with static pressure and shrinks with sound field frequency. The range of diffusionally stable bubble oscillations, found at positive slopes of the habitat-diffusion border, can be increased substantially with static pressure.

  16. Internal friction quality-factor Q under confining pressure. [of lunar rocks

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Ahlberg, L.; Nadler, H.; Curnow, J.; Smith, T.; Cohen, E. R.

    1977-01-01

    It has been found in previous studies that small amounts of adsorbed volatiles can have a profound effect on the internal friction quality-factor Q of rocks and other porous media. Pandit and Tozer (1970) have suggested that the laboratory-measured Q of volatile-free rocks should be similar to the in situ seismic Q values of near-surface lunar rocks which according to Latham et al. (1970) are in the range of 3000-5000. Observations of dramatic increases in Q with outgassing up to values approaching 2000 in the seismic frequency range confirm this supposition. Measurements under confining pressures with the sample encapsulated under hard vacuum are reported to aid in the interpretation of seismic data obtained below the lunar surface. It has been possible to achieve in the experiments Q values just under 2000 at about 1 kbar for a terrestrial analog of lunar basalt. It was found that a well-outgassed sample maintains a high Q whereas one exposed to moisture maintains a low Q as the confining pressure is raised to 2.5 kbar. This result suggests that volatiles can indeed affect Q when cracks are partially closed and the high lunar seismic Q values reported are concomitant with very dry rock down to depths of at least 50 km.

  17. Frequency Response of Pressure Sensitive Paints

    NASA Technical Reports Server (NTRS)

    Winslow, Neal A.; Carroll, Bruce F.; Setzer, Fred M.

    1996-01-01

    An experimental method for measuring the frequency response of Pressure Sensitive Paints (PSP) is presented. These results lead to the development of a dynamic correction technique for PSP measurements which is of great importance to the advancement of PSP as a measurement technique. The ability to design such a dynamic corrector is most easily formed from the frequency response of the given system. An example of this correction technique is shown. In addition to the experimental data, an analytical model for the frequency response is developed from the one dimensional mass diffusion equation.

  18. Forced Longitudinal Oscillations of a Gas in an Open Pipe Near the Resonance Excitation Frequency

    NASA Astrophysics Data System (ADS)

    Zaripov, R. G.; Tkachenko, L. A.; Shaidullin, L. R.

    2017-11-01

    Results of theoretical and experimental investigations of forced longitudinal oscillations of a homogeneous gas in an open pipe near the first natural frequency are presented. It has been established that at the resonance frequency the shape of the gas pressure wave changes with time by a law different from the harmonic one. The amplitude-frequency characteristics of the indicated oscillations have been derived. Satisfactory agreement of the theoretical calculation of the gas pressure oscillation range with experimental data has been obtained.

  19. Respiratory modulation of human autonomic rhythms

    NASA Technical Reports Server (NTRS)

    Badra, L. J.; Cooke, W. H.; Hoag, J. B.; Crossman, A. A.; Kuusela, T. A.; Tahvanainen, K. U.; Eckberg, D. L.

    2001-01-01

    We studied the influence of three types of breathing [spontaneous, frequency controlled (0.25 Hz), and hyperventilation with 100% oxygen] and apnea on R-R interval, photoplethysmographic arterial pressure, and muscle sympathetic rhythms in nine healthy young adults. We integrated fast Fourier transform power spectra over low (0.05-0.15 Hz) and respiratory (0.15-0.3 Hz) frequencies; estimated vagal baroreceptor-cardiac reflex gain at low frequencies with cross-spectral techniques; and used partial coherence analysis to remove the influence of breathing from the R-R interval, systolic pressure, and muscle sympathetic nerve spectra. Coherence among signals varied as functions of both frequency and time. Partialization abolished the coherence among these signals at respiratory but not at low frequencies. The mode of breathing did not influence low-frequency oscillations, and they persisted during apnea. Our study documents the independence of low-frequency rhythms from respiratory activity and suggests that the close correlations that may exist among arterial pressures, R-R intervals, and muscle sympathetic nerve activity at respiratory frequencies result from the influence of respiration on these measures rather than from arterial baroreflex physiology. Most importantly, our results indicate that correlations among autonomic and hemodynamic rhythms vary over time and frequency, and, thus, are facultative rather than fixed.

  20. Experimental study of a valveless pulse detonation rocket engine using nontoxic hypergolic propellants

    NASA Astrophysics Data System (ADS)

    Kan, Brandon K.

    A pulsed detonation rocket engine concept was explored through the use of hypergolic propellants in a fuel-centered pintle injector combustor. The combustor design yielded a simple open ended chamber with a pintle type injection element and pressure instrumentation. High-frequency pressure measurements from the first test series showed the presence of large pressure oscillations in excess of 2000 psia at frequencies between 400-600 hz during operation. High-speed video confirmed the high-frequency pulsed behavior and large amounts of after burning. Damaged hardware and instrumentation failure limited the amount of data gathered in the first test series, but the experiments met original test objectives of producing large over-pressures in an open chamber. A second test series proceeded by replacing hardware and instrumentation, and new data showed that pulsed events produced under expanded exhaust prior to pulsing, peak pressures around 8000 psi, and operating frequencies between 400-800 hz. Later hot-fires produced no pulsed behavior despite undamaged hardware. The research succeeded in producing pulsed combustion behavior using hypergolic fuels in a pintle injector setup and provided insights into design concepts that would assist future injector designs and experimental test setups.

  1. Liquid jet response to internal modulated ultrasonic radiation pressure and stimulated drop production.

    PubMed

    Lonzaga, Joel B; Osterhoudt, Curtis F; Thiessen, David B; Marston, Philip L

    2007-06-01

    Experimental evidence shows that a liquid jet in air is an acoustic waveguide having a cutoff frequency inversely proportional to the jet diameter. Ultrasound applied to the jet supply liquid can propagate within the jet when the acoustic frequency is near to or above the cutoff frequency. Modulated radiation pressure is used to stimulate large amplitude deformations and the breakup of the jet into drops. The jet response to the modulated internal ultrasonic radiation pressure was monitored along the jet using (a) an optical extinction method and (b) images captured by a video camera. The jet profile oscillates at the frequency of the radiation pressure modulation and where the response is small, the amplitude was found to increase in proportion to the square of the acoustic pressure amplitude as previously demonstrated for oscillating drops [P.L. Marston and R.E. Apfel, J. Acoust. Soc. Am. 67, 27-37 (1980)]. Small amplitude deformations initially grow approximately exponentially with axial distance along the jet. Though aspects of the perturbation growth can be approximated from Rayleigh's analysis of the capillary instability, some detailed features of the observed jet response to modulated ultrasound are unexplained neglecting the effects of gravity.

  2. Structural and vibrational properties of solid nitromethane under high pressure by density functional theory.

    PubMed

    Liu, Hong; Zhao, Jijun; Wei, Dongqing; Gong, Zizheng

    2006-03-28

    The structural, vibrational, and electronic properties of solid nitromethane under hydrostatic pressure of up to 20 GPa have been studied using density functional theory. The changes of cell volume, the lattice constants, and the molecular geometry of solid nitromethane under hydrostatic loading are examined, and the bulk modulus B0 and its pressure derivative B0' are fitted from the volume-pressure relation. Our theoretical results are compared with available experiments. The change of electron band gap of nitromethane under high pressure is also discussed. Based on the optimized crystal structures, the vibrational frequencies for the internal and lattice modes of the nitromethane crystal at ambient and high pressures are computed, and the pressure-induced frequency shifts of these modes are discussed.

  3. A new positive relationship between pCO2 and stomatal frequency in Quercus guyavifolia (Fagaceae): a potential proxy for palaeo-CO2 levels

    PubMed Central

    Hu, Jin-Jin; Xing, Yao-Wu; Turkington, Roy; Jacques, Frédéric M. B.; Su, Tao; Huang, Yong-Jiang; Zhou, Zhe-Kun

    2015-01-01

    Background and Aims The inverse relationship between atmospheric CO2 partial pressure (pCO2) and stomatal frequency in many species of plants has been widely used to estimate palaeoatmospheric CO2 (palaeo-CO2) levels; however, the results obtained have been quite variable. This study attempts to find a potential new proxy for palaeo-CO2 levels by analysing stomatal frequency in Quercus guyavifolia (Q. guajavifolia, Fagaceae), an extant dominant species of sclerophyllous forests in the Himalayas with abundant fossil relatives. Methods Stomatal frequency was analysed for extant samples of Q. guyavifolia collected from17 field sites at altitudes ranging between 2493 and 4497 m. Herbarium specimens collected between 1926 and 2011 were also examined. Correlations of pCO2–stomatal frequency were determined using samples from both sources, and these were then applied to Q. preguyavaefolia fossils in order to estimate palaeo-CO2 concentrations for two late-Pliocene floras in south-western China. Key Results In contrast to the negative correlations detected for most other species that have been studied, a positive correlation between pCO2 and stomatal frequency was determined in Q. guyavifolia sampled from both extant field collections and historical herbarium specimens. Palaeo-CO2 concentrations were estimated to be approx. 180–240 ppm in the late Pliocene, which is consistent with most other previous estimates. Conclusions A new positive relationship between pCO2 and stomatal frequency in Q. guyavifolia is presented, which can be applied to the fossils closely related to this species that are widely distributed in the late-Cenozoic strata in order to estimate palaeo-CO2 concentrations. The results show that it is valid to use a positive relationship to estimate palaeo-CO2 concentrations, and the study adds to the variety of stomatal density/index relationships that available for estimating pCO2. The physiological mechanisms underlying this positive response are unclear, however, and require further research. PMID:25681824

  4. An investigation of Ar metastable state density in low pressure dual-frequency capacitively coupled argon and argon-diluted plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wen-Yao; Xu, Yong, E-mail: yongxu@dlut.edu.cn; Peng, Fei

    2015-01-14

    An tunable diode laser absorption spectroscopy has been used to determine the Ar*({sup 3}P{sub 2}) and Ar*({sup 3}P{sub 0}) metastable atoms densities in dual-frequency capacitively coupled plasmas. The effects of different control parameters, such as high-frequency power, gas pressure and content of Ar, on the densities of two metastable atoms and electron density were discussed in single-frequency and dual-frequency Ar discharges, respectively. Particularly, the effects of the pressure on the axial profile of the electron and Ar metastable state densities were also discussed. Furthermore, a simple rate model was employed and its results were compared with experiments to analyze themore » main production and loss processes of Ar metastable states. It is found that Ar metastable state is mainly produced by electron impact excitation from the ground state, and decayed by diffusion and collision quenching with electrons and neutral molecules. Besides, the addition of CF{sub 4} was found to significantly increase the metastable destruction rate by the CF{sub 4} quenching, especially for large CF{sub 4} content and high pressure, it becomes the dominant depopulation process.« less

  5. Innovative UVC light (185 nm) and radio-frequency-plasma pretreatment of Nylon surfaces at atmospheric pressure and their implications in photocatalytic processes.

    PubMed

    Mejía, M I; Marín, J M; Restrepo, G; Pulgarín, C; Mielczarski, E; Mielczarski, J; Stolitchnov, I; Kiwi, J

    2009-10-01

    Innovative pretreatment by UVC light (185 nm) and by radio-frequency (RF) plasma at atmospheric pressure to functionalize the Nylon surface, increasing its bondability toward TiO(2), is reported in this study. In the case of UVC light pretreatment in air, the molar absorption coefficient of O(2)/N(2) at 185 nm is very low and the air in the chamber absorbs very little light from the UVC source before reaching the Nylon sample. Nylon fabrics under RF plasma were also functionalized at atmospheric pressure because of the marked heating effect introduced in the Nylon by the RF plasma. This effect leads to intermolecular bond breaking and oxygenated surface groups in the topmost Nylon layers. Both pretreatments enhanced significantly the photocatalytic discoloration of the red-wine stain in Nylon-TiO(2) compared with samples without pretreatment. The UVC and RF methods in the absence of vacuum imply a considerable cost reduction to functionalize textile surfaces, suggesting a potential industrial application. Red-wine-stain discoloration under simulated sunlight was monitored quantitatively by diffuse-reflectance spectroscopy and by CO(2) evolution. X-ray photoelectron spectroscopy (XPS) was used to monitor the changes of the C, N, and S species on the Nylon topmost layers during the discoloration process. Significant changes in the XPS spectra of Ti 2p peaks were observed during discoloration of the wine spots. Wine stains attenuated the signal of the Ti 2p (458.4 eV) peak in the Nylon-TiO(2)-stained wine sample at time zero (from now on, the time before the discoloration process). Furthermore, a decrease of the wine-related O 1s signal at 529.7 eV and N 1s signal at 399.5 eV was observed during the discoloration process, indicating an efficient catalytic decomposition of the wine pigment on Nylon-TiO(2). X-ray diffraction detected the formation of anatase on the Nylon fibers. High-resolution transmission electron microscopy shows the formation of anatase particles with sizes between 8 and 20 nm.

  6. Central Pulsatile Pressure and Flow Relationship in the Time and Frequency Domain to Characterise Hydraulic Input to the Brain and Cerebral Vascular Impedance.

    PubMed

    Kim, Mi Ok; O'Rourke, Michael F; Adji, Audrey; Avolio, Alberto P

    2016-01-01

    In the time domain, pulsatile flow and pressure can be characterised as the ratio of the late systolic boost of flow or pressure to the pulse amplitude so as to estimate the hydraulic input to the brain. While vascular impedance has been widely used to represent the load presented to the heart by the systemic circulation, it has not been applied to the cerebral circulation.We set out to study the relationship between the pressure and the flow augmentation index (AIx) in the time domain and to determine cerebral vascular impedance using aortic blood pressure and cerebral blood flow waveforms in the frequency domain. Twenty-four young subjects (aged 21-39 years) were recruited; aortic pressure was derived using SphygmoCor from radial pressure. Flow waveforms were recorded from the middle cerebral artery. In three subjects, we performed the Valsalva manoeuvre to investigate their response to physiological intervention. There was a linear relationship between flow and pressure AIx, and cerebral impedance values were similar to those estimated for low resistance vascular beds. Substantial change in pressure and flow wave contour was observed during the Valsalva manoeuvre; however, the relationship in both the time and the frequency domains were unchanged. This confirms that aortic pressure and cerebral flow waveform can be used to study cerebral impedance.

  7. Population genetics inference for longitudinally-sampled mutants under strong selection.

    PubMed

    Lacerda, Miguel; Seoighe, Cathal

    2014-11-01

    Longitudinal allele frequency data are becoming increasingly prevalent. Such samples permit statistical inference of the population genetics parameters that influence the fate of mutant variants. To infer these parameters by maximum likelihood, the mutant frequency is often assumed to evolve according to the Wright-Fisher model. For computational reasons, this discrete model is commonly approximated by a diffusion process that requires the assumption that the forces of natural selection and mutation are weak. This assumption is not always appropriate. For example, mutations that impart drug resistance in pathogens may evolve under strong selective pressure. Here, we present an alternative approximation to the mutant-frequency distribution that does not make any assumptions about the magnitude of selection or mutation and is much more computationally efficient than the standard diffusion approximation. Simulation studies are used to compare the performance of our method to that of the Wright-Fisher and Gaussian diffusion approximations. For large populations, our method is found to provide a much better approximation to the mutant-frequency distribution when selection is strong, while all three methods perform comparably when selection is weak. Importantly, maximum-likelihood estimates of the selection coefficient are severely attenuated when selection is strong under the two diffusion models, but not when our method is used. This is further demonstrated with an application to mutant-frequency data from an experimental study of bacteriophage evolution. We therefore recommend our method for estimating the selection coefficient when the effective population size is too large to utilize the discrete Wright-Fisher model. Copyright © 2014 by the Genetics Society of America.

  8. Mapping the Interactions between Shocks and Mixing Layers in a 3-Stream Supersonic Jet

    NASA Astrophysics Data System (ADS)

    Lewalle, Jacques; Ruscher, Christopher; Kan, Pinqing; Tenney, Andrew; Gogineni, Sivaram; Kiel, Barry

    2015-11-01

    Pressure is obtained from an LES calculation of the supersonic jet (Ma1 = 1 . 6) issuing from a rectangular nozzle in a low-subsonic co-flow; a tertiary flow, also rectangular with Ma3 = 1 insulates the primary jet from an aft-deck plate. The developing jet exhibits complex three-dimensional interactions between oblique shocks, multiple mixing layers and corner vortices, which collectively act as a skeleton for the flow. Our study is based on several plane sections through the pressure field, with short signals (0.1 s duration at 80 kHz sampling rate). Using wavelet-based band-pass filtering and cross-correlations, we map the directions of propagation of information among the various ``bones'' in the skeleton. In particular, we identify upstream propagation in some frequency bands, 3-dimensional interactions between the various shear layers, and several key bones from which the pressure signals, when taken as reference, provide dramatic phase-locking for parts of the skeleton. We acknowledge the support of AFRL through an SBIR grant.

  9. Full-field wrist pulse signal acquisition and analysis by 3D Digital Image Correlation

    NASA Astrophysics Data System (ADS)

    Xue, Yuan; Su, Yong; Zhang, Chi; Xu, Xiaohai; Gao, Zeren; Wu, Shangquan; Zhang, Qingchuan; Wu, Xiaoping

    2017-11-01

    Pulse diagnosis is an essential part in four basic diagnostic methods (inspection, listening, inquiring and palpation) in traditional Chinese medicine, which depends on longtime training and rich experience, so computerized pulse acquisition has been proposed and studied to ensure the objectivity. To imitate the process that doctors using three fingertips with different pressures to feel fluctuations in certain areas containing three acupoints, we established a five dimensional pulse signal acquisition system adopting a non-contacting optical metrology method, 3D digital image correlation, to record the full-field displacements of skin fluctuations under different pressures. The system realizes real-time full-field vibration mode observation with 10 FPS. The maximum sample frequency is 472 Hz for detailed post-processing. After acquisition, the signals are analyzed according to the amplitude, pressure, and pulse wave velocity. The proposed system provides a novel optical approach for digitalizing pulse diagnosis and massive pulse signal data acquisition for various types of patients.

  10. Physiological and Performance Measures for Baseline Concussion Assessment.

    PubMed

    Dobney, Danielle M; Thomas, Scott G; Taha, Tim; Keightley, Michelle

    2017-05-17

    Baseline testing is a common strategy for concussion assessment and management. Research continues to evaluate novel measures for potential to improve baseline testing methods. The primary objective was to; 1) determine the feasibility of including physiological, neuromuscular and mood measures as part of baseline concussion testing protocol, 2) describe typical values in a varsity athlete sample, and 3) estimate the influence of concussion history on these baseline measures. Prospective observational study. University Athletic Therapy Clinic. 100 varsity athletes. Frequency and domain measures of heart rate variability (HRV), blood pressure (BP), grip strength, Profile of Mood States and the Sport Concussion Assessment Tool-2. Physiological, neuromuscular performance and mood measures were feasible at baseline. Participants with a history of two or more previous concussions displayed significantly higher diastolic blood pressure. Females reported higher total mood disturbance compared to males. Physiological and neuromuscular performance measures are safe and feasible as baseline concussion assessment outcomes. History of concussion may have an influence on diastolic blood pressure.

  11. Combined use of infrared and Raman spectra in the characterization of orthoclase under various hydrostatic pressures.

    PubMed

    Liu, Rui; Wang, Zhi-Hua; Xu, Qiang; Yu, Na; Cao, Miao-Cong

    2014-02-01

    Colorless and pink orthoclase from Balikun granite body, East Zhunger in Xinjiang, served as the samples for the research on hydrostatic pressure experiment. The in-situ hydrostatic pressure test for orthoclases was conducted at the room temperature and pressures from 100 to 600 MPa using cubic zirconia anvil cell, with quartz as pressure gauge. The water located in the orthoclases for the conditions of different hydrostatic pressures was characterized through the methods of Fourier transform infrared (FTIR) and Raman spectra. The results showed that there was a linear correlation between the shifting of Raman bands and hydrostatic pressure applied to the feldspar. All of vibration peaks of M-O structural groups in orthoclases, the bending vibration peaks of Si(Al(IV))-O-Si bond and tetrahedron groups of [SiO4] in Raman spectra shifted toward the higher frequency regularly, the drift distance is 2, 2.19 and less than 2 cm(-1) respectively. The spectra of FTIR suggested that there was more water in colorless orthoclases than the pink one under certain conditions of hydrostatic pressure. The intensity and integral area centered at 3420 cm(-1) in FTIR spectra increased with the rising of hydrostatic pressure. The integral area for colorless and pink feldspar in FTIR spectra rose from 120, 1383 cm(-1) under normal pressure to 1570, 2001 cm(-1) at 600 MPa respectively. The experimental results might indicate that the water in the earth crust could enter the orthoclases in certain condition of the aqueous confining pressure.

  12. Genetic diversity and structure of Lolium perenne ssp. multiflorum in California vineyards and orchards indicate potential for spread of herbicide resistance via gene flow.

    PubMed

    Karn, Elizabeth; Jasieniuk, Marie

    2017-07-01

    Management of agroecosystems with herbicides imposes strong selection pressures on weedy plants leading to the evolution of resistance against those herbicides. Resistance to glyphosate in populations of Lolium perenne L. ssp. multiflorum is increasingly common in California, USA, causing economic losses and the loss of effective management tools. To gain insights into the recent evolution of glyphosate resistance in L. perenne in perennial cropping systems of northwest California and to inform management, we investigated the frequency of glyphosate resistance and the genetic diversity and structure of 14 populations. The sampled populations contained frequencies of resistant plants ranging from 10% to 89%. Analyses of neutral genetic variation using microsatellite markers indicated very high genetic diversity within all populations regardless of resistance frequency. Genetic variation was distributed predominantly among individuals within populations rather than among populations or sampled counties, as would be expected for a wide-ranging outcrossing weed species. Bayesian clustering analysis provided evidence of population structuring with extensive admixture between two genetic clusters or gene pools. High genetic diversity and admixture, and low differentiation between populations, strongly suggest the potential for spread of resistance through gene flow and the need for management that limits seed and pollen dispersal in L. perenne .

  13. Plasma processing of large curved surfaces for superconducting rf cavity modification

    DOE PAGES

    Upadhyay, J.; Im, Do; Popović, S.; ...

    2014-12-15

    In this study, plasma based surface modification of niobium is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. The development of the technology based on Cl 2/Ar plasma etching has to address several crucial parameters which influence the etching rate and surface roughness, and eventually, determine cavity performance. This includes dependence of the process on the frequency of the RF generator, gas pressure, power level, the driven (inner) electrode configuration, and the chlorine concentration in the gas mixture during plasma processing. To demonstrate surface layer removal in the asymmetric non-planar geometry, we are using a simplemore » cylindrical cavity with 8 ports symmetrically distributed over the cylinder. The ports are used for diagnosing the plasma parameters and as holders for the samples to be etched. The etching rate is highly correlated with the shape of the inner electrode, radio-frequency (RF) circuit elements, chlorine concentration in the Cl 2/Ar gas mixtures, residence time of reactive species and temperature of the cavity. Using cylindrical electrodes with variable radius, large-surface ring-shaped samples and d.c. bias implementation in the external circuit we have demonstrated substantial average etching rates and outlined the possibility to optimize plasma properties with respect to maximum surface processing effect.« less

  14. Fourier and wavelet analyses of intermittent and resonant pressure components in a slot burner

    NASA Astrophysics Data System (ADS)

    Pagliaroli, Tiziano; Mancinelli, Matteo; Troiani, Guido; Iemma, Umberto; Camussi, Roberto

    2018-01-01

    In laboratory-scale burner it has been observed that the acoustic excitations change the flame topology inducing asymmetry and oscillations. Hence, an acoustic and aeroacoustic study in non reactive condition is of primary importance during the design stage of a new burner in order to avoid the development of standing waves which can force the flame. So wall pressure fluctuations inside and outside of a novel slot burner have been studied experimentally and numerically for a broad range of geometrical parameters and mass flow rates. Wall pressure fluctuations have been measured through cavity-mounted microphones, providing uni- and multi-variate pressure statistics in both the time and frequency domains. Furthermore, since the onset of combustion-driven oscillations is always presaged by intermittent bursts of high amplitude, a wavelet-based conditional sampling procedure was applied to the database in order to detect coherent signatures embedded in the pressure time signals. Since for a particular case the coherent structures identified have a multi-scale signature, a wavelet-based decomposition technique was proposed as well to separate the contribution of the large- and small-scale flow structures to the pressure fluctuation field. As a main outcome of the activity no coupling between standing waves and velocity fluctuations was observed, but only well localized pressure signatures with shape strongly affected by the neighbouring flow physics.

  15. Effect of planecta and ROSE™ on the frequency characteristics of blood pressure-transducer kits.

    PubMed

    Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi

    2015-12-01

    Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE™, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and their frequency characteristics were tested with or without ROSE™. The natural frequency and damping coefficient of each kit were obtained using frequency characteristics analysis software and evaluated by plotting them on the Gardner's chart. By inserting a planecta port, the natural frequency markedly decreased in both the FloTrac sensor kit (from 40 to 22 Hz) and the DTXplus transducer kit (from 35 to 22 Hz). In both kits with one planecta port, the damping coefficient markedly increased by insertion of ROSE™ from 0.2 to 0.5, optimising frequency characteristics. In both kits with two planecta ports, however, the natural frequency decreased from 22 to 12 Hz. The damping coefficient increased from 0.2 to 0.8 by insertion of ROSE™; however, optimisation was not achieved even by ROSE™ insertion. Planecta ports decrease the natural frequency of the kit. ROSE™ is useful to optimise the frequency characteristics in the kits without or with one planecta port. However, optimisation is difficult with two or more planecta ports, even with the ROSE™ device.

  16. Spectral components of human cardiovascular responses to step changes in Lower Body Negative Pressure (LBNP) before and after 22 hour of 6 deg head down bed rest

    NASA Technical Reports Server (NTRS)

    Knapp, C. F.; Evans, J. M.; Grande, K. J.; Murphy, C. D.; Patwardhan, A. R.

    1992-01-01

    Changes in autonomic outflow to peripheral organs during the development of bedrest induced orthostatic intolerance have not been determined. Recent studies have indicated that spectral analysis provides an indirect assessment of these changes. Eight male subjects were studied before and after 22 hours of 6 degree head down bedrest plus Lasix (40 mg. P.P.). Cardiovascular spectra (using an autoregressive technique) were determined for heart rate (HR, ECG), arterial pressure (AP, Finapres), radial artery flow (RF, Hokansen) and respiration rate (RR, BoMed). Spectra were obtained from 2.5 minute segments during control, lower body negative pressure (minus 10, 20, 30, 40, 50 mmHg) and recovery. Bedrest increased HR spectra power in the low frequency (.001 to .041 Hz) range, increased RF power in the low and mid (.04 to .18 Hz) range and increased AP power in the high (.18 to .50 Hz) frequency range. Increasing levels of lower body negative pressure decreased HR power and increased RF power in the high frequency range and decreased AP power in the low frequency range. Since spectral power of HR in the high frequency range has been shown to indicate parasympathetically mediated regulation and power in the low and mid frequency ranges indicates a sympathetic / parasympathetic mixture, then both bedrest and lower body negative pressure appeared to shift sympathetic / parasympathetic balance toward sympathetic regulation of HR. The interpretation of the spectral content of AP and RF with respect to their autonomic origins remains unclear.

  17. Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments

    NASA Technical Reports Server (NTRS)

    Gee, Kent L.; Sommerfeldt, Scott D.; Blotter, Jonathan D.

    2012-01-01

    An acoustic energy-based probe has been developed that incorporates multiple acoustic sensing elements in order to obtain the acoustic pressure and three-dimensional acoustic particle velocity. With these quantities, the user can obtain various energy-based quantities, including acoustic energy density, acoustic intensity, and acoustic impedance. In this specific development, the probe has been designed to operate in an environment characterized by high temperatures and high pressures as is found in the close vicinity of rocket plumes. Given these capabilities, the probe is designed to be used to investigate the acoustic conditions within the plume of a rocket engine or jet engine to facilitate greater understanding of the noise generation mechanisms in those plumes. The probe features sensors mounted inside a solid sphere. The associated electronics for the probe are contained within the sphere and the associated handle for the probe. More importantly, the design of the probe has desirable properties that reduce the bias errors associated with determining the acoustic pressure and velocity using finite sum and difference techniques. The diameter of the probe dictates the lower and upper operating frequencies for the probe, where accurate measurements can be acquired. The current probe design implements a sphere diameter of 1 in. (2.5 cm), which limits the upper operating frequency to about 4.5 kHz. The sensors are operational up to much higher frequencies, and could be used to acquire pressure data at higher frequencies, but the energy-based measurements are limited to that upper frequency. Larger or smaller spherical probes could be designed to go to lower or higher frequency range

  18. Microsystem strategies for sample preparation in biological detection.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Conrad D.; Galambos, Paul C.; Bennett, Dawn Jonita

    2005-03-01

    The objective of this LDRD was to develop microdevice strategies for dealing with samples to be examined in biological detection systems. This includes three sub-components: namely, microdevice fabrication, sample delivery to the microdevice, and sample processing within the microdevice. The first component of this work focused on utilizing Sandia's surface micromachining technology to fabricate small volume (nanoliter) fluidic systems for processing small quantities of biological samples. The next component was to develop interfaces for the surface-micromachined silicon devices. We partnered with Micronics, a commercial company, to produce fluidic manifolds for sample delivery to our silicon devices. Pressure testing was completedmore » to examine the strength of the bond between the pressure-sensitive adhesive layer and the silicon chip. We are also pursuing several other methods, both in house and external, to develop polymer-based fluidic manifolds for packaging silicon-based microfluidic devices. The second component, sample processing, is divided into two sub-tasks: cell collection and cell lysis. Cell collection was achieved using dielectrophoresis, which employs AC fields to collect cells at energized microelectrodes, while rejecting non-cellular particles. Both live and dead Staph. aureus bacteria have been collected using RF frequency dielectrophoresis. Bacteria have been separated from polystyrene microspheres using frequency-shifting dielectrophoresis. Computational modeling was performed to optimize device separation performance, and to predict particle response to the dielectrophoretic traps. Cell lysis is continuing to be pursued using microactuators to mechanically disrupt cell membranes. Novel thermal actuators, which can generate larger forces than previously tested electrostatic actuators, have been incorporated with and tested with cell lysis devices. Significant cell membrane distortion has been observed, but more experiments need to be conducted to determine the effects of the observed distortion on membrane integrity and cell viability. Finally, we are using a commercial PCR DNA amplification system to determine the limits of detectable sample size, and to examine the amplification of DNA bound to microspheres. Our objective is to use microspheres as capture-and-carry chaperones for small molecules such as DNA and proteins, enabling the capture and concentration of the small molecules using dielectrophoresis. Current tests demonstrated amplification of DNA bound to micron-sized polystyrene microspheres using 20-50 microliter volume size reactions.« less

  19. Pressure spectra from single-snapshot tomographic PIV

    NASA Astrophysics Data System (ADS)

    Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio

    2018-03-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV and the microphone reference data. The VIC-based approach, on the other hand, returns results on the order of the reference.

  20. Hybrid simulation of fishbone instabilities in the EAST tokamak

    NASA Astrophysics Data System (ADS)

    Shen, Wei; Fu, Guoyong; Wang, Feng; Xu, Liqing; Li, Guoqiang; Liu, Chengyue; EAST Team

    2017-10-01

    Hybrid simulations with the global kinetic- MHD code M3D-K have been carried out to investigate the linear stability and nonlinear dynamics of beam-driven fishbone in EAST experiment. Linear simulations show that a low frequency fishbone instability is excited at experimental value of beam ion pressure. The mode is mainly driven by low energy beam ions via precessional resonance. The results are consistent with the experimental measurement with respect to mode frequency and mode structure. When the beam ion pressure is increased to exceed a critical value, the low frequency mode transits to a BAE with much higher frequency. Nonlinear simulations show that the frequency of the low frequency fishbone chirps up and down with corresponding hole-clump structures in phase space, consistent with the Berk-Breizman theory. In addition to the low frequency mode, the high frequency BAE is excited during the nonlinear evolution. For the transient case of beam pressure fraction where the low and high frequency modes are simultaneously excited in the linear phase, only one dominant mode appears in the nonlinear phase with frequency jumps up and down during nonlinear evolution. This work is supported by the National Natural Science Foundation of China under Grant Nos. 11605245 and 11505022, and the CASHIPS Director's Fund under Grant No. YZJJ201510, and the Department of Energy Scientific Discovery through Advanced Computing (SciDAC) under Grant No. DE-AC02-09CH11466.

  1. Effect of oxygen at high pressure on spontaneous transmitter release.

    PubMed

    Colton, J S; Colton, C A

    1978-11-01

    The effect of oxygen at high pressure (OHP) on resting membrane properties (effective membrane resistance (Reff) and membrane potential (Vm)) and the spontaneous release of excitatory transmitter were examined at the lobster neuromuscular junction. Pressurization with 100% oxygen to 150 pounds per square inch gauge pressure (psig) or with nitrogen to 150 psig (7,000 mmHg nitrogen and 135 mmHg oxygen) produced a decrease in Reff associated with a hyperpolarization of Vm. These changes, however, returned to control values within 20--30 min after completion of pressurization. Spontaneous release of excitatory transmitter was shown to increase dramatically in the presence of 100% oxygen at 150 psig. The increase in miniature end-plate potential (MEPP) frequency persisted beyond the transient changes seen with Reff and Vm. This effect was selective to oxygen, as pressurization with nitrogen did not produce an increase in MEPP frequency. No change in average MEPP amplitude was seen with either OHP or pressure alone. An OHP-induced increase in MEPP frequency was also seen at the frog neuromuscular junction. The results indicate that both glutamate-mediated and acetylcholine-mediated synaptic transmission are altered by OHP.

  2. Effect of pressure on the Raman-active modes of zircon (ZrSiO4): a first-principles study

    NASA Astrophysics Data System (ADS)

    Sheremetyeva, Natalya; Cherniak, Daniele J.; Watson, E. Bruce; Meunier, Vincent

    2018-02-01

    Density-functional theory (DFT) was employed in a first-principles study of the effects of pressure on the Raman-active modes of zircon (ZrSiO4), using both the generalized gradient and local density approximations (GGA and LDA, respectively). Beginning with the equilibrium structure at zero pressure, we conducted a calibration of the effect of pressure in a manner procedurally similar to an experimental calibration. For pressures between 0 and 7 GPa, we find excellent qualitative agreement of frequency-pressure slopes partial ω /partial P calculated from GGA DFT with results of previous experimental studies. In addition, we were able to rationalize the ω vs. P behavior based on details of the vibrational modes and their atomic displacements. Most of the partial ω /partial P slopes are positive as expected, but the symmetry of the zircon lattice also results in two negative slopes for modes that involve slight shearing and rigid rotation of SiO4 tetrahedra. Overall, LDA yields absolute values of the frequencies of the Raman-active modes in good agreement with experimental values, while GGA reproduces the shift in frequency with pressure especially well.

  3. Evaluation of the impact of noise metrics on tiltrotor aircraft design

    NASA Technical Reports Server (NTRS)

    Sternfeld, H.; Spencer, R.; Ziegenbein, P.

    1995-01-01

    A subjective noise evaluation was conducted in which the test participants evaluated the annoyance of simulated sounds representative of future civil tiltrotor aircraft. The subjective responses were correlated with the noise metrics of A-weighted sound pressure level, overall sound pressure level, and perceived level. The results indicated that correlation between subjective response and A-weighted sound pressure level is considerably enhanced by combining it in a multiple regression with overall sound pressure level. As a single metric, perceived level correlated better than A-weighted sound pressure level due to greater emphasis on low frequency noise components. This latter finding was especially true for indoor noise where the mid and high frequency noise components are attenuated by typical building structure. Using the results of the subjective noise evaluation, the impact on tiltrotor aircraft design was also evaluated. While A-weighted sound pressure level can be reduced by reduction in tip speed, an increase in number of rotor blades is required to achieve significant reduction of low frequency noise as measured by overall sound pressure level. Additional research, however, is required to achieve comparable reductions in impulsive noise due to blade-vortex interaction, and also to achieve reduction in broad band noise.

  4. Method for noninvasive intracranial pressure measurement

    DOEpatents

    Sinha, Dipen N.

    2000-01-01

    An ultrasonic-based method for continuous, noninvasive intracranial pressure (ICP) measurement and monitoring is described. The stress level in the skull bone is affected by pressure. This also changes the interfacial conditions between the dura matter and the skull bone. Standing waves may be set up in the skull bone and the layers in contact with the bone. At specific frequencies, there are resonance peaks in the response of the skull which can be readily detected by sweeping the excitation frequency on an excitation transducer in contact with a subject's head, while monitoring the standing wave characteristics from the signal received on a second, receiving transducer similarly in contact with the subject's head. At a chosen frequency, the phase difference between the excitation signal and the received signal can be determined. This difference can be related to the intracranial pressure and changes therein.

  5. School burnout and heart rate variability: risk of cardiovascular disease and hypertension in young adult females.

    PubMed

    May, Ross W; Seibert, Gregory S; Sanchez-Gonzalez, Marcos A; Fincham, Frank D

    2018-05-01

    Emerging research documents the relationship between school burnout and some indicators of increased cardiovascular risk. Indicators of cardiovascular functioning assessed via ambulatory blood pressure and heart rate variability (HRV) have not been thoroughly explored in this research domain. Therefore, the current study examined relationships between school burnout and indicators of cardiac functioning via 24 h ambulatory blood pressure (BP) and electrocardiogram monitoring in a sample of young adult female undergraduates (N = 88). Two hypotheses were tested: (1) that independent of related negative affective symptomology (depression and anxiety), increased school burnout would be related to greater systolic and diastolic BP, higher low frequency (LF) HRV and lower very low frequency (VLF) HRV, and (2) that lower VLF would be related to greater school burnout independently of LF HRV. Hierarchical multiple regression analyzes showed that school burnout was significantly related to elevated ambulatory BP (systolic and diastolic) and HRV markers of increased cardiac sympathovagal tone. These findings support the hypotheses and suggest that school burnout might be implicated in the development of pre-hypertension or early cardiovascular disease. Study limitations and the need for future longitudinal research are discussed.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takahashi, Masayuki, E-mail: m.takahashi@al.t.u-tokyo.ac.jp; Ohnishi, Naofumi

    A filamentary plasma is reproduced based on a fully kinetic model of electron and ion transports coupled with electromagnetic wave propagation. The discharge plasma transits from discrete to diffusive patterns at a 110-GHz breakdown, with decrease in the ambient pressure, because of the rapid electron diffusion that occurs during an increase in the propagation speed of the ionization front. A discrete plasma is obtained at low pressures when a low-frequency microwave is irradiated because the ionization process becomes more dominant than the electron diffusion, when the electrons are effectively heated by the low-frequency microwave. The propagation speed of the plasmamore » increases with decrease in the incident microwave frequency because of the higher ionization frequency and faster plasma diffusion resulting from the increase in the energy-absorption rate. An external magnetic field is applied to the breakdown volume, which induces plasma filamentation at lower pressures because the electron diffusion is suppressed by the magnetic field. The thrust performance of a microwave rocket is improved by the magnetic fields corresponding to the electron cyclotron resonance (ECR) and its higher-harmonic heating, because slower propagation of the ionization front and larger energy-absorption rates are obtained at lower pressures. It would be advantageous if the fundamental mode of ECR heating is coupled with a lower frequency microwave instead of combining the higher-harmonic ECR heating with the higher frequency microwave. This can improve the thrust performance with smaller magnetic fields even if the propagation speed increases because of the decrease in the incident microwave frequency.« less

  7. Performance and Stability Characteristics of a Uni-Element Swirl Injector for Oxygen-Rich Stage Combustion Cycles

    NASA Technical Reports Server (NTRS)

    Pal, S.; Kalitan, D.; Woodward, R. D.; Santoro, R. J.

    2004-01-01

    A uni-element liquid propellant combustion performance and instability study for liquid RP-1 and hot oxygen-rich pre-burner products was conducted, at a chamber pressure of about 1000 psi. using flush and recessed swirl injectors. High-frequency pressure transducer measurements were analyzed to yield the characteristic frequencies which were compared to expected frequencies of the chamber. Modes, which were discovered to be present within the main chamber included, the first longitudinal, detected at approximately 1950 Hz, and the second longitudinal mode at approximately 3800 Hz. An additional first longitudinal quarter wave mode was measured at a frequency of approximately 23000 Hz for the recessed swirl injector configuration. The characteristic instabilities resulting from these experiments were relatively weak averaging 0.2% to 0.3% of the chamber pressure.

  8. A search for two types of transverse excitations in liquid polyvalent metals at ambient pressure: An ab initio molecular dynamics study of collective excitations in liquid Al, Tl and Ni

    NASA Astrophysics Data System (ADS)

    Bryk, Taras; Demchuk, Taras; Jakse, Noël; Wax, Jean-François

    2018-02-01

    Recent findings of pressure-induced emergence of unusual high-frequency contribution to transverse current spectral functions in several simple liquid metals at high pressures raised a question whether similar features can be observed in liquid metals at ambient conditions. We report here analysis of ab initio molecular dynamics-derived longitudinal (L) and transverse (T) current spectral functions and corresponding dispersions of collective excitations in liquid polyvalent metals Al, Tl, Ni. We have not found evidences of the second branch of high-frequency transverse modes in liquid Al and Ni, while in the case of liquid Tl they were clearly present in transverse dynamics. The vibrational density of states for liquid Tl has a pronounced high-frequency shoulder, which is located right in the frequency range of the second high-frequency transverse branch, while for liquid Al and Ni the vibrational density of states has only a weak indication of possible high-frequency shoulder. The origin of specific behavior of transverse excitations in liquid Tl is discussed.

  9. Normative wideband reflectance, equivalent admittance at the tympanic membrane, and acoustic stapedius reflex threshold in adults

    PubMed Central

    Feeney, M. Patrick; Keefe, Douglas H.; Hunter, Lisa L.; Fitzpatrick, Denis F.; Garinis, Angela C.; Putterman, Daniel B.; McMillan, Garnett P.

    2016-01-01

    Objectives Wideband acoustic immittance (WAI) measures such as pressure reflectance, parameterized by absorbance and group delay, equivalent admittance at the tympanic membrane (TM), and acoustic stapedius reflex threshold (ASRT) describe middle-ear function across a wide frequency range, compared to traditional tests employing a single frequency. The objective of this study was to obtain normative data using these tests for a group of normal hearing adults and investigate test-retest reliability using a longitudinal design. Design A longitudinal prospective design was used to obtain normative test and retest data on clinical and WAI measures. Subjects were 13 males and 20 females (mean age = 25 y). Inclusion criteria included normal audiometry and clinical immittance. Subjects were tested on two separate visits approximately one month apart. Reflectance and equivalent admittance at the TM were measured from 0.25 to 8.0 kHz under three conditions: at ambient pressure in the ear canal and with pressure sweeps from positive to negative pressure (downswept) and negative to positive pressure (upswept). Equivalent admittance at the TM was calculated using admittance measurements at the probe tip which were adjusted using a model of sound transmission in the ear canal and acoustic estimates of ear-canal area and length. Wideband ASRTs were measured at tympanometric peak pressure (TPP) derived from the average TPP of downswept and upswept tympanograms. Descriptive statistics were obtained for all WAI responses, and wideband and clinical ASRTs were compared. Results Mean absorbance at ambient pressure and TPP demonstrated a broad band-pass pattern typical of previous studies. Test-retest differences were lower for absorbance at TPP for the downswept method compared to ambient pressure at frequencies between 1.0 and 1.26 kHz. Mean tympanometric peak-to-tail differences for absorbance were greatest around 1.0 to 2.0 kHz and similar for positive and negative tails. Mean group delay at ambient pressure and at TPP were greatest between 0.32 and 0.6 kHz at 200 to 300 μs, reduced at frequencies between 0.8 and 1.5 kHz, and increased above 1.5 kHz to around 150 μs. Mean equivalent admittance at the TM had a lower level for the ambient method than at TPP for both sweep directions below 1.2 kHz, but the difference between methods was only statistically significant for the comparison between the ambient method and TPP for the upswept tympanogram. Mean equivalent admittance phase was positive at all frequencies. Test-retest reliability of the equivalent admittance level ranged from 1 to 3 dB at frequencies below 1.0 kHz, but increased to 8 to 9 dB at higher frequencies. The mean wideband ASRT for an ipsilateral broadband noise activator was 12 dB lower than the clinical ASRT, but had poorer reliability. Conclusions Normative data for the WAI test battery revealed minor differences for results at ambient pressure compared to tympanometric methods at TPP for reflectance, group delay, and equivalent admittance level at the TM for subjects with middle-ear pressure within ±100 daPa. Test-retest reliability was better for absorbance at TPP for the downswept tympanogram compared to ambient pressure at frequencies around 1.0 kHz. Large peak-to-tail differences in absorbance combined with good reliability at frequencies between about 0.7 and 3.0 kHz suggest that this may be a sensitive frequency range for interpreting absorbance at TPP. The mean wideband ipsilateral ASRT was lower than the clinical ASRT, consistent with previous studies. Results are promising for the use of a wideband test battery to evaluate middle-ear function. PMID:28045835

  10. High-Frequency Percussive Ventilation and Low Tidal Volume Ventilation in Burns: A Randomized Controlled Trial

    DTIC Science & Technology

    2010-01-01

    incidence of ventilator-associated pneumonia ( VAP ) in patients with inha- lation injury when supported with HFPV compared with conventional modes of...mean ratio of PaO2 to FIO2 was 58 6 with a mean positive end- expiratory pressure of 22 2 cm H2O before rescue. Two of these patients were...a sample size of 110 patients in each arm would have been required to detect a difference in VAP with 80% power. A multicentered study would be

  11. Strain-dependent partial slip on rock fractures under seismic-frequency torsion: Seismic-Frequency Fracture Partial Slip

    DOE PAGES

    Saltiel, Seth; Bonner, Brian P.; Ajo-Franklin, Jonathan B.

    2017-05-05

    Measurements of nonlinear modulus and attenuation of fractures provide the opportunity to probe their mechanical state. We have adapted a low-frequency torsional apparatus to explore the seismic signature of fractures under low normal stress, simulating low effective stress environments such as shallow or high pore pressure reservoirs. We report strain-dependent modulus and attenuation for fractured samples of Duperow dolomite (a carbon sequestration target reservoir in Montana), Blue Canyon Dome rhyolite (a geothermal analog reservoir in New Mexico), and Montello granite (a deep basement disposal analog from Wisconsin). We use a simple single effective asperity partial slip model to fit ourmore » measured stress-strain curves, and solve for the friction coefficient, contact radius, and full slip condition. These observations have the potential to develop into new field techniques for measuring differences in frictional properties during reservoir engineering manipulations and estimate the stress conditions where reservoir fractures and faults begin to fully slip.« less

  12. Metamaterial Absorber Based Multifunctional Sensor Application

    NASA Astrophysics Data System (ADS)

    Ozer, Z.; Mamedov, A. M.; Ozbay, E.

    2017-02-01

    In this study metamaterial based (MA) absorber sensor, integrated with an X-band waveguide, is numerically and experimentally suggested for important application including pressure, density sensing and marble type detecting applications based on rectangular split ring resonator, sensor layer and absorber layer that measures of changing in the dielectric constant and/or the thickness of a sensor layer. Changing of physical, chemical or biological parameters in the sensor layer can be detected by measuring the resonant frequency shifting of metamaterial absorber based sensor. Suggested MA based absorber sensor can be used for medical, biological, agricultural and chemical detecting applications in microwave frequency band. We compare the simulation and experimentally obtained results from the fabricated sample which are good agreement. Simulation results show that the proposed structure can detect the changing of the refractive indexes of different materials via special resonance frequencies, thus it could be said that the MA-based sensors have high sensitivity. Additionally due to the simple and tiny structures it could be adapted to other electronic devices in different sizes.

  13. Strain-dependent partial slip on rock fractures under seismic-frequency torsion: Seismic-Frequency Fracture Partial Slip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saltiel, Seth; Bonner, Brian P.; Ajo-Franklin, Jonathan B.

    Measurements of nonlinear modulus and attenuation of fractures provide the opportunity to probe their mechanical state. We have adapted a low-frequency torsional apparatus to explore the seismic signature of fractures under low normal stress, simulating low effective stress environments such as shallow or high pore pressure reservoirs. We report strain-dependent modulus and attenuation for fractured samples of Duperow dolomite (a carbon sequestration target reservoir in Montana), Blue Canyon Dome rhyolite (a geothermal analog reservoir in New Mexico), and Montello granite (a deep basement disposal analog from Wisconsin). We use a simple single effective asperity partial slip model to fit ourmore » measured stress-strain curves, and solve for the friction coefficient, contact radius, and full slip condition. These observations have the potential to develop into new field techniques for measuring differences in frictional properties during reservoir engineering manipulations and estimate the stress conditions where reservoir fractures and faults begin to fully slip.« less

  14. Influence of shielding gas pressure on welding characteristics in CO2 laser-MIG hybrid welding process

    NASA Astrophysics Data System (ADS)

    Chen, Yanbin; Lei, Zhenglong; Li, Liqun; Wu, Lin

    2006-01-01

    The droplet transfer behavior and weld characteristics have been investigated under different pressures of shielding gas in CO2 laser and metal inert/active gas (laser-MIG) hybrid welding process. The experimental results indicate that the inherent droplet transfer frequency and stable welding range of conventional MIG arc are changed due to the interaction between CO2 laser beam and MIG arc in laser-MIG hybrid welding process, and the shielding gas pressure has a crucial effect on welding characteristics. When the pressure of shielding gas is low in comparison with MIG welding, the frequency of droplet transfer decreases, and the droplet transfer becomes unstable in laser-MIG hybrid welding. So the penetration depth decreases, which shows the characteristic of unstable hybrid welding. However, when the pressure of shielding gas increases to a critical value, the hybrid welding characteristic is changed from unstable hybrid welding to stable hybrid welding, and the frequency of droplet transfer and the penetration depth increase significantly.

  15. Mechanisms of Autonomic Dysfunction Associated with Extreme Exertional Heat Stroke and Potential Efficacy of Novel Pharmacological Treatments

    DTIC Science & Technology

    2014-12-01

    cardiovascular diseases. At higher doses, these medications have been prescribed to treat high blood pressure in humans and both may have relevance as...HR, and Tc. § Low frequency (LF) systolic blood pressure variability as an index of sympathetic modulation of vascular tone. § LF and high ... blood pressure variability (LFSYS), LF heart rate variability (LFHR), and high frequency heart rate variability (HFHR) in placebo-, clonidine-, and

  16. Biophysical characterization of low-frequency ultrasound interaction with dental pulp stem cells

    PubMed Central

    2013-01-01

    Background Low-intensity ultrasound is considered an effective non-invasive therapy to stimulate hard tissue repair, in particular to accelerate delayed non-union bone fracture healing. More recently, ultrasound has been proposed as a therapeutic tool to repair and regenerate dental tissues. Our recent work suggested that low-frequency kilohertz-range ultrasound is able to interact with dental pulp cells which could have potential to stimulate dentine reparative processes and hence promote the viability and longevity of teeth. Methods In this study, the biophysical characteristics of low-frequency ultrasound transmission through teeth towards the dental pulp were explored. We conducted cell culture studies using an odontoblast-like/dental pulp cell line, MDPC-23. Half of the samples underwent ultrasound exposure while the other half underwent ‘sham treatment’ where the transducer was submerged into the medium but no ultrasound was generated. Ultrasound was applied directly to the cell cultures using a therapeutic ultrasound device at a frequency of 45 kHz with intensity settings of 10, 25 and 75 mW/cm2 for 5 min. Following ultrasound treatment, the odontoblast-like cells were detached from the culture using a 0.25% Trypsin/EDTA solution, and viable cell numbers were counted. Two-dimensional tooth models based on μ-CT 2D images of the teeth were analyzed using COMSOL as the finite element analysis platform. This was used to confirm experimental results and to demonstrate the potential theory that with the correct combination of frequency and intensity, a tooth can be repaired using small doses of ultrasound. Frequencies in the 30 kHz–1 MHz range were analyzed. For each frequency, pressure/intensity plots provided information on how the intensity changes at each point throughout the propagation path. Spatial peak temporal average (SPTA) intensity was calculated and related to existing optimal spatial average temporal average (SATA) intensity deemed effective for cell proliferation during tooth repair. Results The results demonstrate that odontoblast MDPC-23 cell numbers were significantly increased following three consecutive ultrasound treatments over a 7-day culture period as compared with sham controls underscoring the anabolic effects of ultrasound on these cells. Data show a distinct increase in cell number compared to the sham data after ultrasound treatment for intensities of 10 and 25 mW/cm2 (p < 0.05 and p < 0.01, respectively). Using finite element analysis, we demonstrated that ultrasound does indeed propagate through the mineralized layers of the teeth and into the pulp chamber where it forms a ‘therapeutic’ force field to interact with the living dental pulp cells. This allowed us to observe the pressure/intensity of the wave as it propagates throughout the tooth. A selection of time-dependent snapshots of the pressure/intensity reveal that the lower frequency waves propagate to the pulp and remain within the chamber for a while, which is ideal for cell excitation. Input frequencies and pressures of 30 kHz (70 Pa) and 45 kHz (31 kPa), respectively, with an average SPTA of up to 120 mW/cm2 in the pulp seem to be optimal and agree with the SATA intensities reported experimentally. Conclusions Our data suggest that ultrasound can be harnessed to propagate to the dental pulp region where it can interact with the living cells to promote dentine repair. Further research is required to analyze the precise physical and biological interactions of low-frequency ultrasound with the dental pulp to develop a novel non-invasive tool for dental tissue regeneration. PMID:25516801

  17. Surface treatment of polypropylene (PP) film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, Ujjwal Man, E-mail: umjoshi@gmail.com; Subedi, Deepak Prasad, E-mail: deepaksubedi2001@yahoo.com

    Thin films of polypropylene (PP) are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. PP samples before and after the treatments are studied using contact angle measurements, surface free energy calculations and scanning electron microscopy (SEM). Distilled water (H{sub 2}O), glycerol (C{sub 3}H{sub 8}O{sub 3}) and diiodomethane (CH{sub 2}I{sub 2}) are used as test liquids. The contact angle measurements between test liquids and PP samples are used to determine total surface free energy using sessile drop technique. PP films show a remarkable increase inmore » surface free energy after plasma treatment. SEM analysis of the plasma-treated PP films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably.« less

  18. Raman and thermal-stability studies on annealed HgBa 2CuO 4+δ

    NASA Astrophysics Data System (ADS)

    Ren, Y. T.; Chang, H.; Xiong, Q.; Xue, Y. Y.; Chu, C. W.

    1994-06-01

    We have studied as-synthesized, vacuum-annealed and high-pressure oxygen annealed HgBa 2CuO 4+δ(Hg-1201) using Raman scattering. The apical-oxygen vibrational frequencies showed a slight but systematic shift (590, 591 and 587 cm -1), in agreement with the slight change in the Hg-O bond length from neutron-diffraction results. This suggested that the valence of Hg did not change significantly with oxygen content. The intensity of the ∼ 570 cm -1 peak decreased significantly after vacuum anneal and increased after high-pressure oxygen anneal, confirming the early assignment of this mode to interstitial oxygen. The thermal stability of these samples was studied by increasing laser power. High power density resulted in the decomposition of Hg-1201, mainly to BaCuO 2-δ, suggesting mercury loss upon local heating. It was found that the annealed samples decomposed more easily. In addition, one kind of crystallites exhibited a 326 cm -1 broad peak, which disappeared after high-power irradiation. We propose that this extra peak may come from HgO and/or the defect oxygen O (4).

  19. Pressure dependence of the optical phonon frequencies and the transverse effective charge in AlSb

    NASA Astrophysics Data System (ADS)

    Ves, S.; Strössner, K.; Cardona, M.

    1986-02-01

    The first order Raman scattering by TO and LO phonons has been measured in AlSb under hydrostatic' pressures up to its phase transition. The Raman frequencies increase nearly linear while the transverse effective charge e ∗T are compared with estimates based on pseudopotential and on LCAO calculation. In order to obtain from the measured pressure dependence the corresponding volume coefficients the bulk modulus B O and its pressure derivative BOˌ = {dBO}/{dP} was measured by energy-dispersive X-ray diffraction (B O = 55.1 GPa and BOˌ = 4.55 ).

  20. Development of dynamic calibration methods for POGO pressure transducers. [for space shuttle

    NASA Technical Reports Server (NTRS)

    Hilten, J. S.; Lederer, P. S.; Vezzetti, C. F.; Mayo-Wells, J. F.

    1976-01-01

    Two dynamic pressure sources are described for the calibration of pogo pressure transducers used to measure oscillatory pressures generated in the propulsion system of the space shuttle. Rotation of a mercury-filled tube in a vertical plane at frequencies below 5 Hz generates sinusoidal pressures up to 48 kPa, peak-to-peak; vibrating the same mercury-filled tube sinusoidally in the vertical plane extends the frequency response from 5 Hz to 100 Hz at pressures up to 140 kPa, peak-to-peak. The sinusoidal pressure fluctuations can be generated by both methods in the presence of high pressures (bias) up to 55 MPa. Calibration procedures are given in detail for the use of both sources. The dynamic performance of selected transducers was evaluated using these procedures; the results of these calibrations are presented. Calibrations made with the two sources near 5 Hz agree to within 3% of each other.

  1. Dynamic analysis method for prevention of failure in the first-stage low-pressure turbine blade with two-finger root

    NASA Astrophysics Data System (ADS)

    Park, Jung-Yong; Jung, Yong-Keun; Park, Jong-Jin; Kang, Yong-Ho

    2002-05-01

    Failures of turbine blades are identified as the leading causes of unplanned outages for steam turbine. Accidents of low-pressure turbine blade occupied more than 70 percent in turbine components. Therefore, the prevention of failures for low pressure turbine blades is certainly needed. The procedure is illustrated by the case study. This procedure is used to guide, and support the plant manager's decisions to avoid a costly, unplanned outage. In this study, we are trying to find factors of failures in LP turbine blade and to make three steps to approach the solution of blade failure. First step is to measure natural frequency in mockup test and to compare it with nozzle passing frequency. Second step is to use FEM and to calculate the natural frequencies of 7 blades and 10 blades per group in BLADE code. Third step is to find natural frequencies of grouped blade off the nozzle passing frequency.

  2. Noise attenuation characteristics of a foam type earplug measured using a dummy head.

    PubMed

    Idota, Nozomi; Horie, Seichi; Tsutsui, Takao; Inoue, Jinro

    2002-03-01

    The attenuation characteristics of the earplug using a dummy head (KEMAR; Knowles Electronics Manikin for Acoustic Research) were measured, when it was exposed to pure tones or broadband noises at three different sound pressure levels (SPLs) of 70, 80 and 90 dB SPL in the 'wide frequency range from 250 to 20 k Hz. We ascertained the satisfactory capacity of noise attenuation except for from 10 k to 14 k Hz. The noise attenuation level increased with frequency until 2 k Hz, became almost constant until 8 k Hz, then decreased at around 10 k to 14 k Hz, and recovered in the range from 16 k to 20 k Hz. The frequency characteristics were identical among three different sound pressure levels and almost identical between pure tones and broadband noises. The change of frequency characteristics affected by the depth of the earplug that was inserted into the artificial ear canal of the KEMAR was also investigated. Measured sound pressure level by the builetin microphone in the KEMAR revealed a region in which the measured sound pressure levels were relatively higher around 10 k Hz. The frequency of the region moved higher when the earplug was inserted more deeply. Therefore it was considered that this phenomenon was related to the resonance frequency of the cylinder-like cavity made between the end section of the earplug and the diaphragm of the built-in microphone.

  3. Whole Body Vibration at Different Exposure Frequencies: Infrared Thermography and Physiological Effects

    PubMed Central

    Sonza, Anelise; Robinson, Caroline C.; Achaval, Matilde; Zaro, Milton A.

    2015-01-01

    The aim of this study was to investigate the effects of whole body vibration (WBV) on physiological parameters, cutaneous temperature, tactile sensitivity, and balance. Twenty-four healthy adults (25.3 ± 2.6 years) participated in four WBV sessions. They spent 15 minutes on a vibration platform in the vertical mode at four different frequencies (31, 35, 40, and 44 Hz) with 1 mm of amplitude. All variables were measured before and after WBV exposure. Pressure sensation in five anatomical regions and both feet was determined using Von Frey monofilaments. Postural sway was measured using a force plate. Cutaneous temperature was obtained with an infrared camera. WBV influences the discharge of the skin touch-pressure receptors, decreasing sensitivity at all measured frequencies and foot regions (P ≤ 0.05). Regarding balance, no differences were found after 20 minutes of WBV at frequencies of 31 and 35 Hz. At 40 and 44 Hz, participants showed higher anterior-posterior center of pressure (COP) velocity and length. The cutaneous temperature of the lower limbs decreased during and 10 minutes after WBV. WBV decreases touch-pressure sensitivity at all measured frequencies 10 min after exposure. This may be related to the impaired balance at higher frequencies since these variables have a role in maintaining postural stability. Vasoconstriction might explain the decreased lower limb temperature. PMID:25664338

  4. Surface pressure distributions on a delta wing undergoing large amplitude pitching oscillations. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Thompson, Scott A.

    1989-01-01

    Wind tunnel experiments were performed on a 70 deg sweep delta wing to determine the effect of a sinusoidal pitching motion on the pressure field on the suction side of the wing. Twelve pressure taps were placed from 35 to 90 percent of the chord, at 60 percent of the local semi-span. Pressure coefficients were measured as a function of Reynolds number and pitch rate. The pressure coefficient was seen to vary at approximately the same frequency as the pitching frequency. The relative pressure variation at each chord location was comparable for each case. The average pressure distribution through each periodic motion was near the static distribution for the average angle of attack. Upon comparing the upstroke and downstroke pressures for a specific angle of attack, the downstroke pressures were slightly larger. Vortex breakdown was seen to have the most significant effect at the 40 to 45 percent chord location, where a decrease in pressure was apparent.

  5. Phase Transitions of Triflate-Based Ionic Liquids under High Pressure.

    PubMed

    Faria, Luiz F O; Ribeiro, Mauro C C

    2015-11-05

    Raman spectroscopy has been used to study phase transitions of ionic liquids based on the triflate anion, [TfO](-), as a function of pressure or temperature. Raman spectra of ionic liquids containing the cations 1-butyl-3-methylimidazolium, [C4C1Im](+), 1-octyl-3-methylimidazolium, [C8C1Im](+), 1-butyl-2,3-dimethylimidazolium, [C4C1C1Im](+), and 1-butyl-1-methylpyrrolidinium, [C4C1Pyr](+), were compared. Vibrational frequencies and binding energy of ionic pairs were calculated by quantum chemistry methods. The ionic liquids [C4C1Im][TfO] and [C4C1Pyr][TfO] crystallize at 1.0 GPa when the pressure is increased in steps of ∼ 0.2 GPa from the atmospheric pressure, whereas [C8C1Im][TfO] and [C4C1C1Im][TfO] do not crystallize up to 2.3 GPa of applied pressure. The low-frequency range of the Raman spectrum of [C4C1Im][TfO] indicates that the system undergoes glass transition, rather than crystallization, when the pressure applied on the liquid has been increased above 2.0 GPa in a single step. Strong hysteresis of spectral features (frequency shift and bandwidth) of the high-pressure crystalline phase when the pressure was released stepwise back to the atmospheric pressure has been found .

  6. Predicting burst pressure of radiofrequency-induced colorectal anastomosis by bio-impedance measurement.

    PubMed

    Zhao, Lingxi; Zhou, Yu; Song, Chengli; Wang, Zhigang; Cuschieri, Alfred

    2017-03-01

    The present study investigates the relationship between bio-impedance and burst pressure of colorectal anastomosis created by radiofrequency (RF)-induced tissue fusion. Colorectal anastomosis were created with ex vivo porcine colorectal segments, during which 5 levels of compression pressure were applied by a custom-made bipolar prototype, with 5 replicate experiments at each compression pressure. Instant anastomotic tensile strength was assessed by burst pressure. Bio-impedance of fused tissue was measured by Impedance Analyzer across frequency that 100 Hz to 3 MHz. Statistical analysis shows only a weak correlation between bio-impedance modulus and burst pressures at frequency of 445 kHz ([Formula: see text]  =  -0.426, P  =  0.099  >  0.05). In contrast, results demonstrated a highly significant negative correlation between reactance modulus and burst pressures ([Formula: see text]  =  -0.812, P  =  0.000  <  0.05). The decrease in mean reactance modulus with increasing burst pressures was highly significant (P  =  0.019  <  0.05). The observed strong negative correlation between reactance modulus and burst pressures at frequency of 445 kHz indicates that reactance is likely to be a good index for tensile strength of RF-induced colorectal anastomosis, and should be considered for inclusion in a feedback loops in devices design.

  7. Development of miniature, high frequency pulse tube cryocoolers

    NASA Astrophysics Data System (ADS)

    Radebaugh, Ray; Garaway, Isaac; Veprik, Alexander M.

    2010-04-01

    Because acoustic power density is proportional to frequency, the size of pulse tube cryocoolers for a given refrigeration power can be reduced by operating them at higher frequencies. A frequency of about 60 Hz had been considered the maximum frequency that could be used while maintaining high efficiency. Recently, we have shown through modeling that by decreasing the volume and hydraulic diameter of the regenerator and increasing the average pressure, it is possible to maintain high efficiency even for frequencies of several hundred hertz. Subsequent experimental results have demonstrated high efficiencies for frequencies of 100 to 140 Hz. The very high power density achieved at higher pressures and higher frequencies leads to very short cooldown times and very compact devices. The use of even higher frequencies requires the development of special compressors designed for such conditions and the development of regenerator matrices with hydraulic diameters less than about 30 Μm. To demonstrate the advantages of higher frequency operation, we discuss here the development of a miniature pulse tube cryocooler designed to operate at 80 K with a frequency of 150 Hz and an average pressure of 5.0 MPa. The regenerator diameter and length are 4.4 mm and 27 mm, respectively. The lowest temperature achieved to date has been 97 K, but a net refrigeration power of 530 mW was achieved at 120 K. Acoustic mismatches with existing compressors significantly limit the efficiency, but necessary modifications to improve the acoustic impedance match between the compressor and the cold head are discussed briefly.

  8. Impact of high pressure treatment on functional, rheological, pasting, and structural properties of lentil starch dispersions.

    PubMed

    Ahmed, Jasim; Thomas, Linu; Taher, Ayoub; Joseph, Antony

    2016-11-05

    Lentil starch (LS) dispersions (flour to water 1:4w/w) were subjected to high pressure (HP) treatment at 0.1, 400, 500 and 600MPa for 10min, followed by evaluation on the functional, particle size, rheological, pasting, and structural properties of post-process samples. Water holding capacity of pressurized starch increased with the pressure intensity due to increase in damaged starch. The amount of resistant starch increased from 5 to 6.8% after pressure treatment at 600MPa. An increase in starch granule particle size (196-207μm) was obvious after HP treatment. The lentil starch was completely gelatinized after pressure treatment at 600MPa for 10min as evidenced from differential scanning calorimetry, rheometry, X-ray diffraction (XRD) and scanning electron microscopy observation. The elastic modulus, G' of lentil starch gel was less frequency dependent, and higher in magnitude at high pressure (>500MPa) than at lower pressure range (≤400MPa). XRD analysis revealed the disappearance of two diffraction peak intensities at 14.86° and 22.82° at 600MPa for 10min, which confirms the transformation of crystalline to amorphous region of lentil starch. Pasting properties were significantly influenced by the pressure treatment especially at 600MPa, resulting in a considerable decrease in peak viscosity, breakdown and final viscosity, and an increase in peak time. It can be inferred that the functional properties of pressure-treated LS are mainly based on the structural destruction of granules. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Detecting Pore Fluid Pressure Changes by Using the Vp/Vs Ratio

    NASA Astrophysics Data System (ADS)

    Vanorio, T.; Mavko, G.

    2006-12-01

    A central problem in studies aimed at predicting the dynamic behavior of faults is monitoring and quantifying fluid changes in areas prone to overpressure. Experimental and modeling studies show the Vp/Vs ratio to be a good determinant of the saturation state of a rock formation as well as of its inner pore pressure condition. Dectecting pore pressure changes depends, among other causes, on the reliability of laboratory data to calibrate the in-situ measured velocities. Ideally, laboratory experiments performed under controlled conditions would identify the fundamental mechanisms responsible for changes in the measured acoustic properties. However, technical limitations in the laboratory together with the assumptions driving the experimental and modeling approaches rise spouriuos mechanisms which hinder our present understanding of the actual role of high pore pressure on the elastic and poroelastic parameters. Critical issues unclude: a) the frequencies used in the laboratory are responsible for high-frequency fluid effects which induce velocity dispersion. As a result, both the effective stress parameter and velocities (and their pressure-dependence) estimated from high- frequency ultrasonic data are different from those applicable to crustal low frequency wave propagation; b) laboratory measurements made at dry, drained conditions are assumed to mimic those in gas pressured rocks. However, in dry, drained conditions, no pore pressure is exerted in the pore space, and the pore gas is infinitely compressible; c) when using room-dry, drained measurements as the baseline to model pressured rock formations, the unloading path (i.e. decreasing confining pressure) is supposed to mimic the inflationary path due to pore pressure increase. Doing so, it is assumed that the amount of crack opening due to pore pressure is equal to that of crack closure caused by the overburden stress and thus, the effective stress coefficient is implicitely assumed equal to 1. To minimize the assumptions and limitations described above, we designed a laboratory experiment which used gas as pore fluid medium. Experimental results show that in gas-pressured saturated rocks the Vp/Vs ratio, while remaining lower than values reported for liquid saturation conditions, increases with decreasing differential pressure, similarly to the trend observed in liquid saturated rocks.

  10. Effects on heart pumping function when using foam and gauze for negative pressure wound therapy of sternotomy wounds

    PubMed Central

    2011-01-01

    Background Negative pressure wound therapy (NPWT) has remarkable effects on the healing of poststernotomy mediastinitis. Foam is presently the material of choice for NPWT in this indication. There is now increasing interest in using gauze, as this has proven successful in the treatment of peripheral wounds. It is important to determine the effects of NPWT using gauze on heart pumping function before it can be used for deep sternotomy wounds. The aim was to examine the effects of NPWT when using gauze and foam on the heart pumping function during the treatment of a sternotomy wound. Methods Eight pigs underwent median sternotomy followed by NPWT at -40, -70, -120 and -160 mmHg, using foam or gauze. The heart frequency, cardiac output, mean systemic arterial pressure, mean pulmonary artery pressure, central venous pressure and left atrial pressure were recorded. Results Cardiac output was not affected by NPWT using gauze or foam. Heart frequency decreased during NPWT when using foam, but not gauze. Treatment with foam also lowered the central venous pressure and the left atrial pressure, while gauze had no such effects. Mean systemic arterial pressure, mean pulmonary artery pressure and systemic vascular resistance were not affected by NPWT. Similar haemodynamic effects were observed at all levels of negative pressure studied. Conclusions NPWT using foam results in decreased heart frequency and lower right and left atrial filling pressures. The use of gauze in NPWT did not affect the haemodynamic parameters studied. Gauze may thus provide an alternative to foam for NPWT of sternotomy wounds. PMID:21232105

  11. [Hemodynamic changes in hypoglycemic shock].

    PubMed

    Gutiérrez, C; Piza, R; Chousleb, A; Hidalgo, M A; Ortigosa, J L

    1977-01-01

    Severe hypoglycemia may be present in seriously ill patients; if it is not corrected opportunely a series of neuroendocrinal mechanisms take place aimed at correcting metabolic alterations. These mechanisms can produce hemodynamic alterations as well. Nine mongrel dogs were studied with continuous registration of: blood pressure, central venous pressure, cardiac frequency, respiratory frequency, electrocardiogram and first derivative (Dp/Dt). Six dogs received crystalline (fast acting) insuline intravenously (group 1). After hemodynamic changes were registered hypoglycemia was corrected with 50 per cent glucose solution. Complementary insuline doses were administered to three dogs (group 2); in this group hypoglycemia was not corrected. In group 1 during hypoglycemia there was an increase in blood pressure, central venous pressure, cardiac frequency, respiratory frequency and Dp/Dt, and changes in QT and T wave on the EKG; these changes were partially reversible after hypoglycemia was corrected. The above mentioned alterations persisted in group 2, breathing became irregular irregular and respiratory arrest supervened. It can be inferred that the hemodynamic response to hypoglycemia is predominantly adrenergic. The role of catecolamines, glucocorticoides, glucagon, insuline, cyclic AMP in metabolic and hemodynamic alterations consecutive to hypoglycemia are discussed.

  12. The effects of leading-edge serrations on reducing flow unsteadiness about airfoils, an experimental and analytical investigation

    NASA Technical Reports Server (NTRS)

    Schwind, R. G.; Allen, H. J.

    1973-01-01

    High frequency surface pressure measurements were obtained from wind-tunnel tests over the Reynolds number range 1.2 times one million to 6.2 times one million on a rectangular wing of NACA 63-009 airfoil section. Measurements were also obtained with a wide selection of leading-edge serrations added to the basic airfoil. Under a two-dimensional laminar bubble very close to the leading edge of the basic airfoil there is a large apatial peak in rms pressure. Frequency analysis of the pressure signals in this region show a large, high-frequency energy peak which is interpreted as an oscillation in size and position of the bubble. The serrations divide the bubble into segments and reduce the peak rms pressures. A low Reynolds number flow visualization test on a hydrofoil in water was also conducted. A von Karman vortex street was found trailing from the rear of the foil. Its frequency is at a much lower Strouhal number than in the high Reynolds number experiment, and is related to the trailing-edge and boundary-layer thicknesses.

  13. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    PubMed

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p < 0.001). There were no detrimental effects in terms of lung mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  14. Dynamic considerations for composite metal-rubber laminate acoustic power coupling bellows with application to thermoacoustic refrigeration

    NASA Astrophysics Data System (ADS)

    Smith, Robert William

    Many electrically driven thermoacoustic refrigerators have employed corrugated metal bellows to couple work from an electro-mechanical transducer to the working fluid typically. An alternative bellows structure to mediate this power transfer is proposed: a laminated hollow cylinder comprised of alternating layers of rubber and metal 'hoop-stack'. Fatigue and visoelastic power dissipation in the rubber are critical considerations; strain energy density plays a role in both. Optimal aspect ratios for a rectangle corss-section in the rubber, for given values of bellows axial strain and oscillatory pressure loads are discussed. Comparisons of tearing energies estimated from known load cases and those obtained by finite element analysis for candidate dimensions are presented. The metal layers of bellows are subject to an out-of-plane buckling instability for the case of external pressure loading; failure of this type was experimentally observed. The proposed structure also exhibits column instability when subject to internal pressure, as do metal bellows. For hoop-stack bellows, shear deflection cannot be ignored and this leads to column instability for both internal and external pressures, the latter being analogous to the case of tension buckling of a beam. During prototype bellows testing, transverse modes of vibration are believed to have been excited parametrically as a consequence of the oscillatory pressures. Some operating frequencies of interest in this study lie above the cut-on frequency at which Timoshenko beam theory (TBT) predicts multiple phase speeds; it is shown that TBT fails to accurately predict both mode shapes and resonance frequencies in this regime. TBT is also shown to predict multiple phase speeds in the presence of axial tension, or external pressures, at magnitudes of interest in this study, over the entire frequency spectrum. For modes below cut-on absent a pressure differential (or equivalently, axial load) TBT predicts decreasing resonance frequencies for both internal external static pressure, and converges on known, valid static buckling solutions. Parametric stability in the presence of oscillatory pressure is discussed for such modes; periodic solutions to the Whittaker-Hill equation are pursued to illustrate the shape of the parametric instability regions, and contrasted with results of the more well-known Mathieu equation.

  15. Evaluation of stimulation parameters on aortomyoplasty, using Latissimus Dorsi muscle in a goat model: an acute study.

    PubMed

    Hakami, A; Santamore, W P; Stremel, R W; Tobin, G; Hjortdal, V E

    1999-08-01

    Dynamic aortomyoplasty using Latissimus Dorsi muscle (LDM) has been shown to improve myocardial function. However, systematic examination of the effects of stimulation parameters on aortic wrap function has not been done. Thus, the present study measures the direct effect of stimulation voltage, pulse train duration, frequency of the pulses, and the duration of the stimulation delay from R wave on the aortic wrap function. In eight female goats, the left LDM was wrapped around the descending aorta. The muscle was then subjected to electrical stimulation, altering frequency of stimulation pulses (16.6, 20, 25, 33 and 50 Hz), amplitude (2, 4, 6, 8 and 10 V), and number of pulses (2, 4, 6, 8 and 10 pulses) in a train stimulation. Left ventricular, aortic pressure, and pressure generated by LDM on aorta (wrap pressure) was measured. The changes in hemodynamic parameters mentioned above were calculated and compared for different stimulation parameters during unassisted and assisted cardiac cycles. Aortomyoplasty counterpulsation using LDM provided significant improvement in wrap pressure (78 mmHg +/- 2), aortic diastolic pressure, and changes in aortic diastolic pressure from 2 to 4 V (P < 0.05). Further increase in amplitude did not make any significant improvements of the above mentioned parameters. Significant augmentation of wrap pressure (82 mmHg +/- 2), aortic diastolic pressure (79 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) occurred at 6 pulses (P < 0.05). Other changes in number of pulses did not show any significant improvements. Significant improvement of wrap pressure (80 mmHg +/- 2), aortic diastolic pressure (73 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) was observed with a frequency of 33 Hz. To examine a wide range of delays from the onset of the QRS complex to LDM stimulation, stimulation was delivered randomly. The exact delay was determined from the ECG signal and superimposed LDM stimulation pulses. In this study we present a new measurement, wrap pressure. We also present that in aortomyoplasty using LDM, the most significant improvement in wrap pressure, aortic diastolic pressure and changes in aortic diastolic pressure occurs when the stimulation consists of an amplitude of 4 V, a frequency of 33 Hz and a train stimulation of 6 pulses.

  16. Relationships between blood pressure, polymorphism of angiotensin-converting enzyme (ACE), body composition and biochemical characteristics in elderly Slovaks.

    PubMed

    Siváková, Daniela; Lajdová, Alica; Basistová, Zuzana; Cvícelová, Marta; Karabová, Patrícia; Blazícek, Pavel

    2008-06-01

    Epidemiological studies have demonstrated that several specific environmental factors and candidate genes influence the human variation in blood pressure. The aim of this study was to investigate variables associated with blood pressure; with a particular emphasis on the differences in insertion/deletion (I/D) polymorphism of the human angiotensin-converting enzyme (ACE), the body composition and the recognized risk factors for atherosclerosis among elderly males and females. A total of 374 participants (174 males and 200 females) aged from 60 to 90 years were recruited from different parts of Slovakia. The elderly were not bed-ridden, nor mentally impaired, they were able to manage their daily activities by themselves. The ACE I/D polymorphism was determined by PCR amplification of the ACE gene sequence. Body composition variables were obtained by bioelectrical impedance analysis, using the BIA 101 soft tissue-body impedance analyzer (Akern, S.r.l.). The subjects were determined to be hypertensive (blood pressure > or = 140/90 mm Hg) or normotensive (blood pressure < or = 140/90 mm Hg ). These two subgroups of males and females did not differ significantly in their mean ages. As expected, the hypertensive subjects of both sexes showed significantly higher mean values in systolic (SBP) and diastolic blood pressure (DBP), in body mass index (BMI), and in the mean values of their plasma glucose and extracellular water (ECW). The genotype distribution and allele frequencies in the whole sample (D = 0.5474, I = 0.4526) fell within the Hardy-Weinberg equilibrium. The frequency of the deleterious D allele in the normotensive (0.5532) and hypertensive (0.5516) subjects was not significantly different. The ACE I/D genotypes did not associate either with the systolic (p = 0.836) or diastolic BP (p = 0.629). From the other variables that may induce differences in blood pressure, a statistical effect was detected for glucose, Na/K, and Apo A1/ApoB ratios and physical activity on SBP, and for ApoA1, physical activity, BMI and total cholesterol on DBP.

  17. Performance, Calibration and Stability of the Mars InSight Mission Pressure Sensor

    NASA Astrophysics Data System (ADS)

    Banfield, Don; Banerdt, Bruce; Hurst, Ken; Grinblat, Jonny; murray, alex; Carpenter, Scott

    2017-10-01

    The NASA Mars InSight Discovery Mission is primarily aimed at understanding the seismic environment at Mars and in turn the interior structure of the planet. To this end, it carries a set of very sensitive seismometers to characterize fine ground movements from quakes, impacts and tides. However, to remove atmospheric perturbations that would otherwise corrupt the seismic signals, InSight also carries a pressure sensor of unprecedented sensitivity and frequency response for a Mars mission.The instrument is based on a commercial spacecraft pressure sensor built by the Tavis Corporation. Tavis heritage transducers have provided pressure measurements on several interplanetary missions, starting with a similar application on the Viking Landers. The sensor developed for the Insight mission is their most sensitive device. That same sensitivity was the root of the challenges faced in the design and development for Insight. It uses inductive sensing of a deformable membrane, and includes an internal temperature sensor to compensate for temperature effects in its overall response.The technical requirement on the pressure sensor performance is 0.01(f/0.1)^(-2/3) Pa/sqrt(Hz) between 0.01 and 0.1 Hz, and 0.01 Pa/sqrt(Hz) between 0.1 and 1 Hz. The actual noise spectrum is about 0.01(f/0.3)^(-2/3) Pa/sqrt(Hz) between 0.01 and 1 Hz, and its frequency response (including inlet plumbing) has good response up to about 10 Hz Nyquist (it will be sampled at 20 Hz).Achieving the required sensitivity proved to be a difficult engineering challenge, which necessitated extensive experimentation and prototyping of the electronics design. In addition, a late discovery of the introduction of noise by the signal processing chain into the measurement stream forced a last-minute change in the instrument’s firmware.The flight unit has been calibrated twice, separated by a time span of about 2 years due to the delay in launching the InSight mission. This has the benefit of allowing a direct measure of the stability of the pressure sensor over time. We will discuss the details of the performance, calibration and stability of the pressure sensor in more detail in our presentation.

  18. Resonance frequencies of lipid-shelled microbubbles in the regime of nonlinear oscillations

    PubMed Central

    Doinikov, Alexander A.; Haac, Jillian F.; Dayton, Paul A.

    2009-01-01

    Knowledge of resonant frequencies of contrast microbubbles is important for the optimization of ultrasound contrast imaging and therapeutic techniques. To date, however, there are estimates of resonance frequencies of contrast microbubbles only for the regime of linear oscillation. The present paper proposes an approach for evaluating resonance frequencies of contrast agent microbubbles in the regime of nonlinear oscillation. The approach is based on the calculation of the time-averaged oscillation power of the radial bubble oscillation. The proposed procedure was verified for free bubbles in the frequency range 1–4 MHz and then applied to lipid-shelled microbubbles insonified with a single 20-cycle acoustic pulse at two values of the acoustic pressure amplitude, 100 kPa and 200 kPa, and at four frequencies: 1.5, 2.0, 2.5, and 3.0 MHz. It is shown that, as the acoustic pressure amplitude is increased, the resonance frequency of a lipid-shelled microbubble tends to decrease in comparison with its linear resonance frequency. Analysis of existing shell models reveals that models that treat the lipid shell as a linear viscoelastic solid appear may be challenged to provide the observed tendency in the behavior of the resonance frequency at increasing acoustic pressure. The conclusion is drawn that the further development of shell models could be improved by the consideration of nonlinear rheological laws. PMID:18977009

  19. Non-linear lumped model circuit of capacitively coupled plasmas at the intermediate radio-frequencies

    NASA Astrophysics Data System (ADS)

    Shihab, Mohammed

    2018-06-01

    The discharge dynamics in geometrically asymmetric capacitively coupled plasmas are investigated via a lumped model circuit. A realistic reactor configuration is assumed. A single and two separate RF voltage sources are considered. One of the driven frequencies (the higher frequency) has been adjusted to excite a plasma series resonance, while the second frequency (the lower frequency) is in the range of the ion plasma frequency. Increasing the plasma pressure in the low pressure regime (≤ 100mTorr) is found to diminish the amplitude of the self-excited harmonics of the discharge current, however, the net result is enhancing the plasma heating. The modulation of the ion density with the lower driving frequency affect the plasma heating considerably. The net effect depends on the amplitude and the phase of the ion modulation.

  20. Healthcare performance and the effects of the binaural beats on human blood pressure and heart rate.

    PubMed

    Carter, Calvin

    2008-01-01

    Binaural beats are the differences in two different frequencies (in the range of 30-1000 Hz). Binaural beats are played through headphones and are perceived by the superior olivary nucleus of each hemisphere of the brain. The brain perceives the binaural beat and resonates to its frequency (frequency following response). Once the brain is in tune with the binaural beat it produces brainwaves of that frequency altering the listener's state of mind. In this experiment, the effects of the beta and theta binaural beat on human blood pressure and pulse were studied. Using headphones, three sounds were played for 7 minutes each to 12 participants: the control,- the sound of a babbling brook (the background sound to the two binaural beats), the beta binaural beat (20 Hz), and the theta binaural beat (7 Hz). Blood pressure and pulse were recorded before and after each sound was played. Each participant was given 2 minutes in-between each sound. The results showed that the control and the two binaural beats did not affect the 12 participant's blood pressure or pulse (p > 0.05). One reason for this may be that the sounds were not played long enough for the brain to either perceive and/or resonate to the frequency. Another reason why the sounds did not affect blood pressure and pulse may be due to the participant's age since older brains may not perceive the binaural beats as well as younger brains.

  1. Development of a Piezoelectric Polymer Film Pressure Transducer for Low Frequency and Dynamic Pressure Measurement

    DTIC Science & Technology

    1990-12-01

    Sample LOTUS 123 Cell Formulas for Reducing Reset Data A2: 0.0008 B2: 0.564 C2: -2.501 02: (A1-$A$1) E2: (@IF(@ABS(C2)>2,@TRUE,@FALSE)=1) F2: (@IF(E2...9 F14: (@IF( El4 =1,0,0.951*C14)) H14: (G14- 12 .492*D14) A15: 0.0034 B15: -0.248 015: 0.033 D15: (A14-$A$l) G15: @IF(El5=O, (F15+$G$1 1), (($G$1 1+Gl4...data corrected for rise rate and zero mean. I I F-4 I LOTUS 123 Cell Formulas Used to Reconstruct the Sine Data Al: 0.00324 Bi: -0.01 Cl: -0.14 D1: (Al

  2. Limitations and possibilities of AC calorimetry in diamond anvil cells

    NASA Astrophysics Data System (ADS)

    Geballe, Zachary; Colins, Gilbert; Jeanloz, Raymond

    2013-06-01

    Dynamic laser heating or internal resistive heating could allow for the determination of calorimetric properties of samples that are held statically at high pressure. However, the highly non-adiabatic environment of high-pressure cells presents several challenges. Here, we quantify the errors in AC calorimetry measurements using laser heating or internal resistive heating inside diamond anvil cells, summarize the equipment requirements of supplying sufficient power modulated at a high enough frequency to measure specific heats and latent heats of phase transitions, and propose two new experiments in internally-heated diamond anvil cells: an absolute measurement of specific heat (with ~10% uncertainty) of non-magnetic metals using resistive heating at ~10 MHz, and a relative measurement to detect changes in either the specific heat of metals or in the effusively (the product of specific heat, density and thermal conductivity) of an insulator.

  3. Incidence of swallowing during exercise in horses with dorsal displacement of the soft palate.

    PubMed

    Pigott, J H; Ducharme, N G; Mitchell, L M; Soderholm, L V; Cheetham, J

    2010-11-01

    The relationship between dorsal displacement of the soft palate (DDSP) and swallowing is unclear. To quantify the relationship between DDSP and swallowing in horses at exercise. The frequency of swallowing increases immediately prior to DDSP in horses at exercise. Videoendoscopic and upper airway pressure data were collated from horses with a definitive diagnosis of DDSP at exercise. Horses with no upper airway abnormalities were matched by age, breed and sex and used as controls. Sixty-nine horses were identified with a definitive diagnosis of DDSP during the study interval. Airway pressure data were available for 42 horses. The majority of horses displaced at high exercising speeds while accelerating; a smaller number displaced during deceleration after peak speed had been reached. Horses swallowed significantly more frequently in the 1 min immediately preceding DDSP than in the control horses at equivalent speeds. DDSP at exercise results in a significant increase in tracheal expiratory pressure, a significant decrease in pharyngeal expiratory pressure and a significantly less negative pharyngeal inspiratory pressure compared to matched controls and compared to the pressures during the 1 min interval prior to DDSP. There was no significant difference between any measure of airway pressure before or after a swallow when examined at each time interval in the DDSP population. The frequency of swallowing decreases with increasing speed in normal horses. In contrast, the frequency of swallowing increases immediately prior to onset of DDSP. This is not a result of pharyngeal and tracheal pressure changes. The increased frequency of swallowing observed prior to DDSP may be related to the aetiology of the disease. © 2010 EVJ Ltd.

  4. Resonant Doppler velocimeter. Ph.D. Thesis. Final Report, 1 Jul. 1974 - 31 Oct. 1979; [velocity, temperature, and pressure measurement

    NASA Technical Reports Server (NTRS)

    Zimmermann, M.

    1980-01-01

    A technique is presented for visualizing and quantitatively measuring velocity, temperature, and pressure by shining a single frequency laser beam into a gaseous flow which is seeded with an atomic species. The laser is tuned through the absorption frequencies of the seeded species and the absorption profile is detected by observing fluorescence as the atoms relax back to the ground state. The flow velocity is determined by observing the Doppler shift in the absorption frequency. Spectroscopic absorption line broadening mechanisms furnish information regarding the static temperature and pressure of the moving gas. Results of experiments conducted in the free stream and in the bow shock of a conical model mounted in a hypersonic wind tunnel indicate that the experimental uncertainties in the measurement of average values for the velocity, temperature and pressure of the flow are 0.1, 5 and 10 percent respectively.

  5. Alumina ceramic based high-temperature performance of wireless passive pressure sensor

    NASA Astrophysics Data System (ADS)

    Wang, Bo; Wu, Guozhu; Guo, Tao; Tan, Qiulin

    2016-12-01

    A wireless passive pressure sensor equivalent to inductive-capacitive (LC) resonance circuit and based on alumina ceramic is fabricated by using high temperature sintering ceramic and post-fire metallization processes. Cylindrical copper spiral reader antenna and insulation layer are designed to realize the wireless measurement for the sensor in high temperature environment. The high temperature performance of the sensor is analyzed and discussed by studying the phase-frequency and amplitude-frequency characteristics of reader antenna. The average frequency change of sensor is 0.68 kHz/°C when the temperature changes from 27°C to 700°C and the relative change of twice measurements is 2.12%, with high characteristic of repeatability. The study of temperature-drift characteristic of pressure sensor in high temperature environment lays a good basis for the temperature compensation methods and insures the pressure signal readout accurately.

  6. Water Flow Testing and Unsteady Pressure Analysis of a Two-Bladed Liquid Oxidizer Pump Inducer

    NASA Technical Reports Server (NTRS)

    Schwarz, Jordan B.; Mulder, Andrew; Zoladz, Thomas

    2011-01-01

    The unsteady fluid dynamic performance of a cavitating two-bladed oxidizer turbopump inducer was characterized through sub-scale water flow testing. While testing a novel inlet duct design that included a cavitation suppression groove, unusual high-frequency pressure oscillations were observed. With potential implications for inducer blade loads, these high-frequency components were analyzed extensively in order to understand their origins and impacts to blade loading. Water flow testing provides a technique to determine pump performance without the costs and hazards associated with handling cryogenic propellants. Water has a similar density and Reynolds number to liquid oxygen. In a 70%-scale water flow test, the inducer-only pump performance was evaluated. Over a range of flow rates, the pump inlet pressure was gradually reduced, causing the flow to cavitate near the pump inducer. A nominal, smooth inducer inlet was tested, followed by an inlet duct with a circumferential groove designed to suppress cavitation. A subsequent 52%-scale water flow test in another facility evaluated the combined inducer-impeller pump performance. With the nominal inlet design, the inducer showed traditional cavitation and surge characteristics. Significant bearing loads were created by large side loads on the inducer during synchronous cavitation. The grooved inlet successfully mitigated these loads by greatly reducing synchronous cavitation, however high-frequency pressure oscillations were observed over a range of frequencies. Analytical signal processing techniques showed these oscillations to be created by a rotating, multi-celled train of pressure pulses, and subsequent CFD analysis suggested that such pulses could be created by the interaction of rotating inducer blades with fluid trapped in a cavitation suppression groove. Despite their relatively low amplitude, these high-frequency pressure oscillations posed a design concern due to their sensitivity to flow conditions and test scale. The amplitude and frequency of oscillations varied considerably over the pump s operating space, making it difficult to predict blade loads.

  7. Human responses to upright tilt: a window on central autonomic integration

    NASA Technical Reports Server (NTRS)

    Cooke, W. H.; Hoag, J. B.; Crossman, A. A.; Kuusela, T. A.; Tahvanainen, K. U.; Eckberg, D. L.

    1999-01-01

    1. We examined interactions between haemodynamic and autonomic neural oscillations during passive upright tilt, to gain better insight into human autonomic regulatory mechanisms. 2. We recorded the electrocardiogram, finger photoplethysmographic arterial pressure, respiration and peroneal nerve muscle sympathetic activity in nine healthy young adults. Subjects breathed in time with a metronome at 12 breaths min-1 (0.2 Hz) for 5 min each, in supine, and 20, 40, 60, 70 and 80 deg head-up positions. We performed fast Fourier transform (and autoregressive) power spectral analyses and integrated low-frequency (0.05-0.15 Hz) and respiratory-frequency (0. 15-0.5 Hz) spectral powers. 3. Integrated areas of muscle sympathetic bursts and their low- and respiratory-frequency spectral powers increased directly and significantly with the tilt angle. The centre frequency of low-frequency sympathetic oscillations was constant before and during tilt. Sympathetic bursts occurred more commonly during expiration than inspiration at low tilt angles, but occurred equally in expiration and inspiration at high tilt angles. 4. Systolic and diastolic pressures and their low- and respiratory-frequency spectral powers increased, and R-R intervals and their respiratory-frequency spectral power decreased progressively with the tilt angle. Low-frequency R-R interval spectral power did not change. 5. The cross-spectral phase angle between systolic pressures and R-R intervals remained constant and consistently negative at the low frequency, but shifted progressively from positive to negative at the respiratory frequency during tilt. The arterial baroreflex modulus, calculated from low-frequency cross-spectra, decreased at high tilt angles. 6. Our results document changes of baroreflex responses during upright tilt, which may reflect leftward movement of subjects on their arterial pressure sympathetic and vagal response relations. The intensity, but not the centre frequency of low-frequency cardiovascular rhythms, is modulated by the level of arterial baroreceptor input. Tilt reduces respiratory gating of sympathetic and vagal motoneurone responsiveness to stimulatory inputs for different reasons; during tilt, sympathetic stimulation increases to a level that overwhelms the respiratory gate, and vagal stimulation decreases to a level below that necessary for maximal respiratory gating to occur.

  8. Human responses to upright tilt: a window on central autonomic integration.

    PubMed

    Cooke, W H; Hoag, J B; Crossman, A A; Kuusela, T A; Tahvanainen, K U; Eckberg, D L

    1999-06-01

    1. We examined interactions between haemodynamic and autonomic neural oscillations during passive upright tilt, to gain better insight into human autonomic regulatory mechanisms. 2. We recorded the electrocardiogram, finger photoplethysmographic arterial pressure, respiration and peroneal nerve muscle sympathetic activity in nine healthy young adults. Subjects breathed in time with a metronome at 12 breaths min-1 (0.2 Hz) for 5 min each, in supine, and 20, 40, 60, 70 and 80 deg head-up positions. We performed fast Fourier transform (and autoregressive) power spectral analyses and integrated low-frequency (0.05-0.15 Hz) and respiratory-frequency (0. 15-0.5 Hz) spectral powers. 3. Integrated areas of muscle sympathetic bursts and their low- and respiratory-frequency spectral powers increased directly and significantly with the tilt angle. The centre frequency of low-frequency sympathetic oscillations was constant before and during tilt. Sympathetic bursts occurred more commonly during expiration than inspiration at low tilt angles, but occurred equally in expiration and inspiration at high tilt angles. 4. Systolic and diastolic pressures and their low- and respiratory-frequency spectral powers increased, and R-R intervals and their respiratory-frequency spectral power decreased progressively with the tilt angle. Low-frequency R-R interval spectral power did not change. 5. The cross-spectral phase angle between systolic pressures and R-R intervals remained constant and consistently negative at the low frequency, but shifted progressively from positive to negative at the respiratory frequency during tilt. The arterial baroreflex modulus, calculated from low-frequency cross-spectra, decreased at high tilt angles. 6. Our results document changes of baroreflex responses during upright tilt, which may reflect leftward movement of subjects on their arterial pressure sympathetic and vagal response relations. The intensity, but not the centre frequency of low-frequency cardiovascular rhythms, is modulated by the level of arterial baroreceptor input. Tilt reduces respiratory gating of sympathetic and vagal motoneurone responsiveness to stimulatory inputs for different reasons; during tilt, sympathetic stimulation increases to a level that overwhelms the respiratory gate, and vagal stimulation decreases to a level below that necessary for maximal respiratory gating to occur.

  9. Preliminary work about the reproduction of sonic boom signals for perception studies

    NASA Astrophysics Data System (ADS)

    Epain, N.; Herzog, P.; Rabau, G.; Friot, E.

    2006-05-01

    As part of a French research program, a sound restitution cabin was designed for investigating the annoyance of sonic boom signals. The first goal was to reproduce the boom spectrum and temporal waveform: this required linear generation of high pressure levels at infrasonic frequencies (110 SPL dB around 3 Hz), and response equalization over the full frequency range (1 Hz-20 kHz). At this stage the pressure inside the cabin was almost uniform around the listener, emulating an outdoor situation. A psychoacoustic study was then conducted which confirmed that the loudness (related to annoyance) of N-waves is roughly governed by the peak pressure, the rise/fall time, and the wave duration. A longer-term goal is to reproduce other aspects of an indoor situation including rattle noise, ground vibrations, and a more realistic spatial repartition of pressure. This latter point has been addressed through an Active Noise Control study aiming at monitoring the low-frequency acoustic pressure on a surface enclosing a listener. Frequency and time-domain numerical simulations of boom reproduction via ANC are given, including a sensitivity study of the coupling between a listener's head and the incident boom wave which combine into the effective sound-field to be reproduced.

  10. The effects of pressure sensor acoustics on airdata derived from a High-angle-of-attack Flush Airdata Sensing (HI-FADS) system

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Moes, Timothy R.

    1991-01-01

    The accuracy of a nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was verified for quasi-steady flight conditions up to 55 deg angle of attack during the F-18 High Alpha Research Vehicle (HARV) Program. The system is a matrix of nine pressure ports arranged in annular rings on the aircraft nose. The complete airdata set is estimated using nonlinear regression. Satisfactory frequency response was verified to the system Nyquist frequency (12.5 Hz). The effects of acoustical distortions within the individual pressure sensors of the nonintrusive pressure matrix on overall system performance are addressed. To quantify these effects, a frequency-response model describing the dynamics of acoustical distortion is developed and simple design criteria are derived. The model adjusts measured HI-FADS pressure data for the acoustical distortion and quantifies the effects of internal sensor geometries on system performance. Analysis results indicate that sensor frequency response characteristics very greatly with altitude, thus it is difficult to select satisfactory sensor geometry for all altitudes. The solution used presample filtering to eliminate resonance effects, and short pneumatic tubing sections to reduce lag effects. Without presample signal conditioning the system designer must use the pneumatic transmission line to attenuate the resonances and accept the resulting altitude variability.

  11. The effects of extra-low-frequency atmospheric pressure oscillations on human mental activity

    NASA Astrophysics Data System (ADS)

    Delyukov, A. A.; Didyk, L.

    Slight atmospheric pressure oscillations (APO) in the extra-low-frequency range below 0.1 Hz, which frequently occur naturally, can influence human mental activity. This phenomenon has been observed in experiments with a group of 12 healthy volunteers exposed to experimentally created APO with amplitudes 30-50 Pa in the frequency band 0.011-0.17 Hz. Exposure of the subjects to APO for 15-30 min caused significant changes in attention and short-term memory functions, performance rate, and mental processing flexibility. The character of the response depended on the APO frequency and coherence. Periodic APO promoted purposeful mental activity, accompanied by an increase in breath-holding duration and a slower heart rate. On the other hand, quasi-chaotic APO, similar to the natural perturbations of atmospheric pressure, disrupted mental activity. These observations suggest that APO could be partly responsible for meteorosensitivity in humans.

  12. Vocal warm-up increases phonation threshold pressure in soprano singers at high pitch.

    PubMed

    Motel, Tamara; Fisher, Kimberly V; Leydon, Ciara

    2003-06-01

    Vocal warm-up is thought to optimize singing performance. We compared effects of short-term, submaximal, vocal warm-up exercise with those of vocal rest on the soprano voice (n = 10, ages 19-21 years). Dependent variables were the minimum subglottic air pressure required for vocal fold oscillation to occur (phonation threshold pressure, Pth), and the maximum and minimum phonation fundamental frequency. Warm-up increased Pth for high pitch phonation (p = 0.033), but not for comfortable (p = 0.297) or low (p = 0.087) pitch phonation. No significant difference in the maximum phonation frequency (p = 0.193) or minimum frequency (p = 0.222) was observed. An elevated Pth at controlled high pitch, but an unchanging maximum and minimum frequency production suggests that short-term vocal exercise may increase the viscosity of the vocal fold and thus serve to stabilize the high voice.

  13. Resonant tube for measurement of sound absorption in gases at low frequency/pressure ratios

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.; Griffin, W. A.

    1980-01-01

    The paper describes a resonant tube for measuring sound absorption in gases, with specific emphasis on the vibrational relaxation peak of N2, over a range of frequency/pressure ratios from 0.1 to 2500 Hz/atm. The experimental background losses measured in argon agree with the theoretical wall losses except at few isolated frequencies. Rigid cavity terminations, external excitation, and a differential technique of background evaluation were used to minimize spurious contributions to the background losses. Room temperature measurements of sound absorption in binary mixtures of N2-CO2 in which both components are excitable resulted in the maximum frequency/pressure ratio in Hz/atm of 0.063 + 123m for the N2 vibrational relaxation peak, where m is mole percent of added CO2; the maximum ratio for the CO2 peak was 34,500 268m where m is mole percent of added N2.

  14. Space Shuttle Redesigned Solid Rocket Motor nozzle natural frequency variations with burn time

    NASA Technical Reports Server (NTRS)

    Lui, C. Y.; Mason, D. R.

    1991-01-01

    The effects of erosion and thermal degradation on the Space Shuttle Redesigned Solid Rocket Motor (RSRM) nozzle's structural dynamic characteristics were analytically evaluated. Also considered was stiffening of the structure due to internal pressurization. A detailed NASTRAN finite element model of the nozzle was developed and used to evaluate the influence of these effects at several discrete times during motor burn. Methods were developed for treating erosion and thermal degradation, and a procedure was developed to account for internal pressure stiffening using differential stiffness matrix techniques. Results were verified using static firing test accelerometer data. Fast Fourier Transform and Maximum Entropy Method techniques were applied to the data to generate waterfall plots which track modal frequencies with burn time. Results indicate that the lower frequency nozzle 'vectoring' modes are only slightly affected by erosion, thermal effects and internal pressurization. The higher frequency shell modes of the nozzle are, however, significantly reduced.

  15. Impact of Dietary Acculturation on the Food Habits, Weight, Blood Pressure, and Fasting Blood Glucose Levels of International College Students.

    PubMed

    Almohanna, Amal; Conforti, Frank; Eigel, William; Barbeau, William

    2015-01-01

    This study was conducted to determine the impact of dietary acculturation on the health status of newly arrived international students at Virginia Tech in Fall 2010. Thirty-five international students, 18-36 years of age, completed the study. Data were collected at 3 different time periods (V1, V2, and V3) approximately 6 weeks apart. A food frequency- and dietary pattern-related questionnaire was administered and numerically coded responses were analyzed. Twenty-four-hour dietary recall data were also collected at V1, V2, and V3. Body weight, fasting blood glucose level, and blood pressure of study participants were also determined at each time period. Total sample population (TSP) had a significant increase in mean weight of 2.79 lb from visit 1 (V1) to visit 3 (V3) (p = .0082). Ten participants gained an average of 9.0 lb (participants who gained weight; n = 10). There was also an increase in the frequency of consumption of high-calorie American food items from V1 to V3. However, there were no significant changes in mean systolic blood pressure and mean fasting blood glucose was significantly lower at V3 than at V1. There was a gradual shift in the dietary patterns of international students towards the American diet. Dietary acculturation led to weight gain among some of the students, which may potentially have a negative impact on their health status if continued for longer time periods.

  16. Numerical Simulation and Validation of a High Head Model Francis Turbine at Part Load Operating Condition

    NASA Astrophysics Data System (ADS)

    Goyal, Rahul; Trivedi, Chirag; Kumar Gandhi, Bhupendra; Cervantes, Michel J.

    2017-07-01

    Hydraulic turbines are operated over an extended operating range to meet the real time electricity demand. Turbines operated at part load have flow parameters not matching the designed ones. This results in unstable flow conditions in the runner and draft tube developing low frequency and high amplitude pressure pulsations. The unsteady pressure pulsations affect the dynamic stability of the turbine and cause additional fatigue. The work presented in this paper discusses the flow field investigation of a high head model Francis turbine at part load: 50% of the rated load. Numerical simulation of the complete turbine has been performed. Unsteady pressure pulsations in the vaneless space, runner, and draft tube are investigated and validated with available experimental data. Detailed analysis of the rotor stator interaction and draft tube flow field are performed and discussed. The analysis shows the presence of a rotating vortex rope in the draft tube at the frequency of 0.3 times of the runner rotational frequency. The frequency of the vortex rope precession, which causes severe fluctuations and vibrations in the draft tube, is predicted within 3.9% of the experimental measured value. The vortex rope results pressure pulsations propagating in the system whose frequency is also perceive in the runner and upstream the runner.

  17. Improved oxygenation 24 hours after transition to airway pressure release ventilation or high-frequency oscillatory ventilation accurately discriminates survival in immunocompromised pediatric patients with acute respiratory distress syndrome*.

    PubMed

    Yehya, Nadir; Topjian, Alexis A; Thomas, Neal J; Friess, Stuart H

    2014-05-01

    Children with an immunocompromised condition and requiring invasive mechanical ventilation have high risk of death. Such patients are commonly transitioned to rescue modes of nonconventional ventilation, including airway pressure release ventilation and high-frequency oscillatory ventilation, for acute respiratory distress syndrome refractory to conventional ventilation. Our aim was to describe our experience with airway pressure release ventilation and high-frequency oscillatory ventilation in children with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation and to identify factors associated with survival. Retrospective cohort study. Tertiary care, university-affiliated PICU. Sixty pediatric patients with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation transitioned to either airway pressure release ventilation or high-frequency oscillatory ventilation. None. Demographic data, ventilator settings, arterial blood gases, oxygenation index, and PaO(2)/FIO(2) were recorded before transition to either mode of nonconventional ventilation and at predetermined intervals after transition for up to 5 days. Mortality in the entire cohort was 63% and did not differ between patients transitioned to airway pressure release ventilation and high-frequency oscillatory ventilation. For both airway pressure release ventilation and high-frequency oscillatory ventilation, improvements in oxygenation index and PaO(2)/FIO(2) at 24 hours expressed as a fraction of pretransition values (oxygenation index(24)/oxygenation index(pre) and PaO(2)/FIO(224)/PaO(2)/FIO(2pre)) reliably discriminated nonsurvivors from survivors, with receiver operating characteristic areas under the curves between 0.89 and 0.95 (p for all curves < 0.001). Sensitivity-specificity analysis suggested that less than 15% reduction in oxygenation index (90% sensitive, 75% specific) or less than 90% increase in PaO(2)/FIO(2) (80% sensitive, 94% specific) 24 hours after transition to airway pressure release ventilation were the optimal cutoffs to identify nonsurvivors. The comparable values 24 hours after transition to high-frequency oscillatory ventilation were less than 5% reduction in oxygenation index (100% sensitive, 83% specific) or less than 80% increase in PaO(2)/FIO(2) (91% sensitive, 89% specific) to identify nonsurvivors. In this single-center retrospective study of pediatric patients with an immunocompromised condition and acute respiratory distress syndrome failing conventional ventilation transitioned to either airway pressure release ventilation or high-frequency oscillatory ventilation, improved oxygenation at 24 hours expressed as PaO(2)/FIO(224)/PaO(2)/FIO(2pre) or oxygenation index(24)/oxygenation indexpre reliably discriminates nonsurvivors from survivors. These findings should be prospectively verified.

  18. Modeling seismic stimulation: Enhanced non-aqueous fluid extraction from saturated porous media under pore-pressure pulsing at low frequencies

    NASA Astrophysics Data System (ADS)

    Lo, Wei-Cheng; Sposito, Garrison; Huang, Yu-Han

    2012-03-01

    Seismic stimulation, the application of low-frequency stress-pulsing to the boundary of a porous medium containing water and a non-aqueous fluid to enhance the removal of the latter, shows great promise for both contaminated groundwater remediation and enhanced oil recovery, but theory to elucidate the underlying mechanisms lag significantly behind the progress achieved in experimental research. We address this conceptual lacuna by formulating a boundary-value problem to describe pore-pressure pulsing at seismic frequencies that is based on the continuum theory of poroelasticity for an elastic porous medium permeated by two immiscible fluids. An exact analytical solution is presented that is applied numerically using elasticity parameters and hydraulic data relevant to recent proof-of-principle laboratory experiments investigating the stimulation-induced mobilization of trichloroethene (TCE) in water flowing through a compressed sand core. The numerical results indicated that significant stimulation-induced increases of the TCE concentration in effluent can be expected from pore-pressure pulsing in the frequency range of 25-100 Hz, which is in good agreement with what was observed in the laboratory experiments. Sensitivity analysis of our numerical results revealed that the TCE concentration in the effluent increases with the porous medium framework compressibility and the pulsing pressure. Increasing compressibility also leads to an optimal stimulation response at lower frequencies, whereas changing the pulsing pressure does not affect the optimal stimulation frequency. Within the context of our model, the dominant physical cause for enhancement of non-aqueous fluid mobility by seismic stimulation is the dilatory motion of the porous medium in which the solid and fluid phases undergo opposite displacements, resulting in stress-induced changes of the pore volume.

  19. Selective loss of orientation column maps in visual cortex during brief elevation of intraocular pressure.

    PubMed

    Chen, Xin; Sun, Chao; Huang, Luoxiu; Shou, Tiande

    2003-01-01

    To compare the orientation column maps elicited by different spatial frequency gratings in cortical area 17 of cats before and during brief elevation of intraocular pressure (IOP). IOP was elevated by injecting saline into the anterior chamber of a cat's eye through a syringe needle. The IOP was elevated enough to cause a retinal perfusion pressure (arterial pressure minus IOP) of approximately 30 mm Hg during a brief elevation of IOP. The visual stimulus gratings were varied in spatial frequency, whereas other parameters were kept constant. The orientation column maps of the cortical area 17 were monocularly elicited by drifting gratings of different spatial frequencies and revealed by a brain intrinsic signal optical imaging system. These maps were compared before and during short-term elevation of IOP. The response amplitude of the orientation maps in area 17 decreased during a brief elevation of IOP. This decrease was dependent on the retinal perfusion pressure but not on the absolute IOP. The location of the most visible maps was spatial-frequency dependent. The blurring or loss of the pattern of the orientation maps was most severe when high-spatial-frequency gratings were used and appeared most significantly on the posterior part of the exposed cortex while IOP was elevated. However, the basic patterns of the maps remained unchanged. Changes in cortical signal were not due to changes in the optics of the eye with elevation of IOP. A stable normal IOP is essential for maintaining normal visual cortical functions. During a brief and high elevation of IOP, the cortical processing of high-spatial-frequency visual information was diminished because of a selectively functional decline of the retinogeniculocortical X pathway by a mechanism of retinal circulation origin.

  20. Subjective assessment of simulated helicopter blade-slap noise

    NASA Technical Reports Server (NTRS)

    Lawton, B. W.

    1976-01-01

    The effects of several characteristics of helicopter blade slap upon human annoyance are examined. Blade slap noise was simulated by using continuous and impulsive noises characterized by five parameters: The number of sine waves in a single impulse; the frequency of the sine waves; the impulse repetition frequency; the sound pressure level (SPL) of the continuous noise; and the idealized crest factor of the impulses. Ten second samples of noise were synthesized with each of the five parameters at representative levels. The annoyance of each noise was judged by 40 human subjects. Analysis of the subjective data indicated that each of the five parameters had a statistically significant effect upon the annoyance judgments. The impulse crest factor and SPL of the continuous noise had very strong positive relationships with annoyance. The other parameters had smaller, but still significant, effects upon the annoyance judgments.

  1. Autonomic Impairment in Severe Traumatic Brain Injury: A Multimodal Neuromonitoring Study.

    PubMed

    Sykora, Marek; Czosnyka, Marek; Liu, Xiuyun; Donnelly, Joseph; Nasr, Nathalie; Diedler, Jennifer; Okoroafor, Francois; Hutchinson, Peter; Menon, David; Smielewski, Peter

    2016-06-01

    Autonomic impairment after acute traumatic brain injury has been associated independently with both increased morbidity and mortality. Links between autonomic impairment and increased intracranial pressure or impaired cerebral autoregulation have been described as well. However, relationships between autonomic impairment, intracranial pressure, impaired cerebral autoregulation, and outcome remain poorly explored. Using continuous measurements of heart rate variability and baroreflex sensitivity we aimed to test whether autonomic markers are associated with functional outcome and mortality independently of intracranial variables. Further, we aimed to evaluate the relationships between autonomic functions, intracranial pressure, and cerebral autoregulation. Retrospective analysis of a prospective database. Neurocritical care unit in a university hospital. Sedated patients with severe traumatic brain injury. Waveforms of intracranial pressure and arterial blood pressure, baseline Glasgow Coma Scale and 6 months Glasgow Outcome Scale were recorded. Baroreflex sensitivity was assessed every 10 seconds using a modified cross-correlational method. Frequency domain analyses of heart rate variability were performed automatically every 10 seconds from a moving 300 seconds of the monitoring time window. Mean values of baroreflex sensitivity, heart rate variability, intracranial pressure, arterial blood pressure, cerebral perfusion pressure, and impaired cerebral autoregulation over the entire monitoring period were calculated for each patient. Two hundred and sixty-two patients with a median age of 36 years entered the analysis. The median admission Glasgow Coma Scale was 6, the median Glasgow Outcome Scale was 3, and the mortality at 6 months was 23%. Baroreflex sensitivity (adjusted odds ratio, 0.9; p = 0.02) and relative power of a high frequency band of heart rate variability (adjusted odds ratio, 1.05; p < 0.001) were individually associated with mortality, independently of age, admission Glasgow Coma Scale, intracranial pressure, pressure reactivity index, or cerebral perfusion pressure. Baroreflex sensitivity showed no correlation with intracranial pressure or cerebral perfusion pressure; the correlation with pressure reactivity index was strong in older patients (age, > 60 yr). The relative power of high frequency correlated significantly with intracranial pressure and cerebral perfusion pressure, but not with pressure reactivity index. The relative power of low frequency correlated significantly with pressure reactivity index. Autonomic impairment, as measured by heart rate variability and baroreflex sensitivity, is significantly associated with increased mortality after traumatic brain injury. These effects, though partially interlinked, seem to be independent of age, trauma severity, intracranial pressure, or autoregulatory status, and thus represent a discrete phenomenon in the pathophysiology of traumatic brain injury. Continuous measurements of heart rate variability and baroreflex sensitivity in the neuromonitoring setting of severe traumatic brain injury may carry novel pathophysiological and predictive information.

  2. Acoustic characteristics of simulated respiratory-induced vocal tremor.

    PubMed

    Lester, Rosemary A; Story, Brad H

    2013-05-01

    The purpose of this study was to investigate the relation of respiratory forced oscillation to the acoustic characteristics of vocal tremor. Acoustical analyses were performed to determine the characteristics of the intensity and fundamental frequency (F0) for speech samples obtained by Farinella, Hixon, Hoit, Story, and Jones (2006) using a respiratory forced oscillation paradigm with 5 healthy adult males to simulate vocal tremor involving respiratory pressure modulation. The analyzed conditions were sustained productions of /a/ with amplitudes of applied pressure of 0, 1, 2, and 4 cmH2O and a rate of 5 Hz. Forced oscillation of the respiratory system produced modulation of the intensity and F0 for all participants. Variability was observed between participants and conditions in the change in intensity and F0 per unit of pressure change, as well as in the mean intensity and F0. However, the extent of modulation of intensity and F0 generally increased as the applied pressure increased, as would be expected. These findings suggest that individuals develop idiosyncratic adaptations to pressure modulations, which are important to understanding aspects of variability in vocal tremor, and highlight the need to assess all components of the speech mechanism that may be directly or indirectly affected by tremor.

  3. Progress on Pre-Stage Magnetic Coil to Enhance Helicon Mode Excitation and Data Acquisition Software on the Helicon Plasma Experiment (HPX)

    NASA Astrophysics Data System (ADS)

    Sherman, Justin; Azzari, Phillip; Crilly, P. B.; Duke-Tinson, Omar; James, Royce W.; Karama, Jackson; Page, E. J.; Schlank, Carter; Zuniga, Jonathan

    2014-10-01

    CGAPL is conducting small investigations in plasma physics and magneto-hydrodynamics buoy positioning. For data management, we are developing capability to analyze/digitize data with a National Instruments Data Acquisition board, 2 MS/s sampling rate (long time scale), and an Express Octopus card, 125 MS/s sampling rate (short scale). Sampling at 12 bits precision, we use LabVIEW as a programing language; GUIs will control variables in 1 or more concurrent runs and monitor of diagnostics. HPX utilizes high density (1013 cm3 up), low pressure (.01 T) Ar gas (fill pressure: on 104 mTorr order). Helicon/W Mode plasmas become a diagnostics test-bed for other investigations and a tool for future spacecraft propulsion devices. Plasmas created by directing energy into gas-filled Pyrex tube; power supply and matching box, up to 250 W power in 20-100 MHz frequencies, provide energy to ignite. Uniform magnetic field needed to reach the W-Mode. We employ an electromagnet to B-field while an acceleration coil positions plasma in vacuum chamber, facilitating analysis. Initial field requirements and accuracy calibration have been completed. Progress on development and implementation of probes and DAQ/GUI system will be reported. Supported by U.S. DEPS Grant [HEL-JTO] PRWJFY13.

  4. On the efficacy of spatial sampling using manual scanning paths to determine the spatial average sound pressure level in rooms.

    PubMed

    Hopkins, Carl

    2011-05-01

    In architectural acoustics, noise control and environmental noise, there are often steady-state signals for which it is necessary to measure the spatial average, sound pressure level inside rooms. This requires using fixed microphone positions, mechanical scanning devices, or manual scanning. In comparison with mechanical scanning devices, the human body allows manual scanning to trace out complex geometrical paths in three-dimensional space. To determine the efficacy of manual scanning paths in terms of an equivalent number of uncorrelated samples, an analytical approach is solved numerically. The benchmark used to assess these paths is a minimum of five uncorrelated fixed microphone positions at frequencies above 200 Hz. For paths involving an operator walking across the room, potential problems exist with walking noise and non-uniform scanning speeds. Hence, paths are considered based on a fixed standing position or rotation of the body about a fixed point. In empty rooms, it is shown that a circle, helix, or cylindrical-type path satisfy the benchmark requirement with the latter two paths being highly efficient at generating large number of uncorrelated samples. In furnished rooms where there is limited space for the operator to move, an efficient path comprises three semicircles with 45°-60° separations.

  5. On the Use of Experimental Methods to Improve Confidence in Educed Impedance

    NASA Technical Reports Server (NTRS)

    Jones, Michael G.; Watson, Willie R.

    2011-01-01

    Results from impedance eduction methods developed by NASA Langley Research Center are used throughout the acoustic liner community. In spite of recent enhancements, occasional anomalies persist with these methods, generally at frequencies where the liner produces minimal attenuation. This investigation demonstrates an experimental approach to educe impedance with increased confidence over a desired frequency range, by combining results from successive tests with different cavity depths. A series of tests is conducted with three wire-mesh facesheets, for which the results should be weakly dependent on source sound pressure level and mean grazing flow speed. First, a raylometer is used to measure the DC flow resistance of each facesheet. These facesheets are then mounted onto a frame and a normal incidence tube is used to determine their respective acoustic impedance spectra. A comparison of the acoustic resistance component with the DC flow resistance for each facesheet is used to validate the measurement process. Next, each facesheet is successively mounted onto three frames with different cavity depths, and a grazing flow impedance tube is used to educe their respective acoustic impedance spectra with and without mean flow. The no-flow results are compared with those measured in the normal incidence tube to validate the impedance eduction method. Since the anti-resonance frequency varies with cavity depth, each sample provides robust results over a different frequency range. Hence, a combination of results can be used to determine the facesheet acoustic resistance. When combined with the acoustic reactance, observed to be weakly dependent on the source sound pressure level and grazing flow Mach number, the acoustic impedance can be educed with increased confidence. Representative results of these tests are discussed, and the complete database is available in electronic format upon request.

  6. Association of eating frequency with anthropometric indices and blood pressure in children and adolescents: the CASPIAN-IV Study.

    PubMed

    Kelishadi, Roya; Qorbani, Mostafa; Motlagh, Mohammad Esmaeil; Heshmat, Ramin; Ardalan, Gelayol; Bahreynian, Maryam

    2016-01-01

    This study was conducted to explore the association of eating frequency (EF) with anthropometric indices and blood pressure (BP) in children and adolescents. This nationwide cross-sectional study was performed on a multi-stage sample of 14,880 students, aged 6-18 years, living in 30 provinces in Iran. Parents were asked to report dietary intake of children as frequency of food groups and/or items. EF was defined as the sum of the daily consumption frequency of main meals and snacks. Association of EF with weight disorders, abdominal obesity, and elevated BP was assessed using different logistic regression models adjusted for potential confounding factors. Eating more frequently (≥ 6 vs. ≤ 3) was found among students who were at younger age (11.91 vs. 13.29 years) (p<0.001). Students who reported an EF of 4 (OR: 0.67, CI: 0.57-0.79), 5 (OR: 0.74, CI: 0.62-0.87), and 6 (OR: 0.54, CI: 0.44-0.65) had lower odds of being obese compared to those who had EF ≤ 3. Having EF of 4 (OR: 0.82, CI: 0.71-0.94), 5 (OR: 0.86, CI: 0.74-0.99), and ≥ 6 (OR: 0.73, CI: 0.63-0.85) was related to lower prevalence of abdominal adiposity. Higher EF was associated with lower mean values of anthropometric and BP measures, as well as with lower prevalence of generalized and abdominal obesity in children and adolescents. Longitudinal studies are needed to assess the long-term effects of EF on body composition in the pediatric age group. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  7. A dynamic pressure source for the calibration of pressure transducers

    NASA Technical Reports Server (NTRS)

    Vezzetti, C. F.; Hilten, J. S.; Mayo-Wells, J. F.; Lederer, P. S.

    1976-01-01

    A dynamic pressure source is described for producing sinusoidally varying pressures of up to 34 kPa zero to peak, over the frequency range of approximately 50 Hz to 2 kHz. The source is intended for the dynamic calibration of pressure transducers. The transducer to be calibrated is mounted near the base of the thick walled aluminum tube forming the vessel so that the pressure sensitive element is in contact with the liquid in the tube. A section of the tube is filled with small steel balls to damp the motion of the 10-St dimethyl siloxane working fluid in order to extend the useful frquency range to higher frequencies than would be provided by an undamped system. The dynamic response of six transducers provided by the sponsor was evaluated using the pressure sources; the results of these calibrations are given.

  8. Urban African American Pre-Adolescent Social Problem Solving Skills: Family Influences and Association with Exposure to Situations of Sexual Possibility

    PubMed Central

    Traube, Dorian E.; Chasse, Kelly Taber; McKay, Mary M.; Bhorade, Anjali M.; Paikoff, Roberta; Young, Stacie D.

    2010-01-01

    SUMMARY The results of two studies focusing on the social problem solving skills of African American preadolescent youth are detailed. In the first study data from a sample of 150 African American children, ages 9 to 11 years, was used to examine the association between type of youth social problem solving approaches applied to hypothetical risk situations and time spent in unsupervised peer situations of sexual possibility. Findings revealed that children with more exposure to sexual possibility situations generated a wider range of social problem solving strategies, but these approaches tended to be unrealistic and ambiguous. Further, there was a positive association between the amount of time spent unsupervised and youth difficulty formulating a definitive response to hypothetical peer pressure situations. Children with less exposure to sexual possibility situations tended to be more aggressive when approaching situations of peer pressure. In the second study, data from a non-overlapping sample of 164 urban, African American adult caregivers and their 9 to 11 year old children was examined in order to explore the associations between child gender, family-level factors including family communication frequency and intensity, time spent in situations of sexual possibility, and youth social problem solving approaches. Results revealed that children were frequently using constructive problem solving and help seeking behaviors when confronted by difficult social situations and that there was a significant relationship between the frequency and intensity of parent child communication and youth help seeking social problem solving approaches. Implications for research and family-based interventions are highlighted. PMID:20871790

  9. Multiparity modifies contractile properties of pelvic muscles affecting the genesis of vaginal pressure in rabbits.

    PubMed

    López-Juárez, Rhode; Zempoalteca, René; Corona-Quintanilla, Dora Luz; Jiménez-Estrada, Ismael; Castelán, Francisco; Martínez-Gómez, Margarita

    2018-01-01

    To characterize the contractile properties of the bulbospongiosus (Bsm), isquiocavernosus (Ism), and pubococcygeus muscles (Pcm), and their involvement in the genesis of vaginal pressure in nulliparous and multiparous rabbits. Age-matched nulliparous and multiparous rabbits were used to record the isometric contractile responses of each muscle as well as the intravaginal pressure evoked by single square electrical pulses and stimulation trains of ascending frequency. To establish significant differences between groups, two-tail unpaired Student t tests were carried out. The linear correlation between intravaginal pressure and muscle contractile force was analyzed with Pearson correlation tests. For all cases, a P ≤ 0.05 was set as statistically significant. Multiparity decreased the contractile force of Bsm and Ism generated by high-frequency stimulation trains. The normalized force of the Pcm increased when evoked at 1, 4, and 10 Hz while this decreased at higher frequencies (20, 50, and 100 Hz). The contraction of both Bsm and Ism raised particularly the pressure on the perineal vagina while that of the Pcm increased the pressure in the pelvic vagina. Such a functional segregation is still present in multiparous rabbits albeit it was modified. Multiparity induces changes in the contractile responses of Bsm, Ism, and Pcm, which alterates the vaginal pressure. © 2017 Wiley Periodicals, Inc.

  10. A transmission-line model of back-cavity dynamics for in-plane pressure-differential microphones.

    PubMed

    Kim, Donghwan; Kuntzman, Michael L; Hall, Neal A

    2014-11-01

    Pressure-differential microphones inspired by the hearing mechanism of a special parasitoid fly have been described previously. The designs employ a beam structure that rotates about two pivots over an enclosed back volume. The back volume is only partially enclosed due to open slits around the perimeter of the beam. The open slits enable incoming sound waves to affect the pressure profile in the microphone's back volume. The goal of this work is to study the net moment applied to pressure-differential microphones by an incoming sound wave, which in-turn requires modeling the acoustic pressure distribution within the back volume. A lumped-element distributed transmission-line model of the back volume is introduced for this purpose. It is discovered that the net applied moment follows a low-pass filter behavior such that, at frequencies below a corner frequency depending on geometrical parameters of the design, the applied moment is unaffected by the open slits. This is in contrast to the high-pass filter behavior introduced by barometric pressure vents in conventional omnidirectional microphones. The model accurately predicts observed curvature in the frequency response of a prototype pressure-differential microphone 2 mm × 1 mm × 0.5 mm in size and employing piezoelectric readout.

  11. 78 FR 30873 - Takes of Marine Mammals Incidental to Specified Activities; Taking Marine Mammals Incidental to a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-23

    ..., administered by Space and Naval Warfare Systems Command (SPAWAR) Systems Center (SSC), would be moved... stream of water under high pressure) would be another option to loosen piles that could not be removed... which are frequency, wavelength, velocity, and amplitude. Frequency is the number of pressure waves that...

  12. Infrasonic Monitoring,

    DTIC Science & Technology

    1995-08-14

    seismic network. At large range, infrasound signals are oscillatory acoustic signals detected as small pressure variations about the ambient value... Infrasound Review and Background Infrasound signals are regular acoustic signals in that they are longitudinal pressure waves albeit at rather low frequency...energy is concentrated at higher frequency than that for higher yield sources. Infrasound can be generated by natural and manmade processes; moreover

  13. Identification of low and high frequency ranges for heart rate variability and blood pressure variability analyses using pharmacological autonomic blockade with atropine and propranolol in swine.

    USDA-ARS?s Scientific Manuscript database

    Understanding autonomic nervous system functioning, which mediates behavioral and physiological responses to stress, offers great potential for evaluation of farm animal stress and welfare. Evaluation of heart rate variability (HRV) and blood pressure variability (BPV), using time and frequency doma...

  14. A silicon micromachined resonant pressure sensor

    NASA Astrophysics Data System (ADS)

    Tang, Zhangyang; Fan, Shangchun; Cai, Chenguang

    2009-09-01

    This paper describes the design, fabrication and test of a silicon micromachined resonant pressure sensor. A square membrane and a doubly clamped resonant beam constitute a compound structure. The former senses the pressure directly, while the latter changes its resonant frequency according to deformation of the membrane. The final output relation between the resonant frequency and the applied pressure is deducted according to the structure mechanical properties. Sensors are fabricated by micromachining technology, and then sealed in vaccum. These sensors are tested by open-loop and close-loop system designed on purpose. The experiment results demonstrate that the sensor has a sensitivity of 49.8Hz/kPa and repeatability of 0.08%.

  15. Pressure Dependence of the Radial Breathing Mode of Carbon Nanotubes: The Effect of Fluid Adsorption

    NASA Astrophysics Data System (ADS)

    Longhurst, M. J.; Quirke, N.

    2007-04-01

    The pressure dependence of shifts in the vibrational modes of individual carbon nanotubes is strongly affected by the nature of the pressure transmitting medium as a result of adsorption at the nanotube surface. The adsorbate is treated as an elastic shell which couples with the radial breathing mode (RBM) of the nanotube via van der Waal interactions. Using analytical methods as well as molecular simulation, we observe a low frequency breathing mode for the adsorbed fluid at ˜50cm-1, as well as diameter dependent upshifts in the RBM frequency with pressure, suggesting metallic nanotubes may wet more than semiconducting ones.

  16. Spectral analysis of unsteady surface pressure on a pusher propeller

    NASA Technical Reports Server (NTRS)

    Farokhi, Saeed

    1992-01-01

    A propeller of an advanced turboprop testbed aircraft in pusher configuration is instrumented with 22 miniature blade-mounted transducers (BMTs) at two radii. Upstream pylon wake interaction with the propeller is the source of a one-per-cycle excitation for the blades in flight. The time history of fluctuating pressure signals over 26 flight conditions is statistically analyzed in the frequency domain. The rms amplitude of fluctuating pressure signals measured by suction surface BMTs indicates a very strong presence of the fundamental frequency over most of the upper surface. The pylon wake pressure signature on the propeller trailing edge, i.e., x/c not less than 0.80, shows predominantly random turbulence; hence, the amplitude of the fundamental frequency wave is fairly small. The resurgence of a large amplitude fundamental harmonic with coherent pylon wake signature further downstream, say at 90 percent chord, is unexpected behavior. The appearance of a dominating second propeller shaft order in the spectra of the rms pressure in transonic flight conditions identifies the presence of a two-per-cycle excitation source in the azimuthal direction. This is due to the presence of a shock wave, as evidenced by the pressure-time history plots.

  17. Methods and apparatus for moving and separating materials exhibiting different physical properties

    DOEpatents

    Peterson, Stephen C.; Brimhall, Owen D.; McLaughlin, Thomas J.; Baker, Charles D.; Sparks, Sam L.

    1991-01-01

    Methods and apparatus for controlling the movement of materials having different physical properties when one of the materials is a fluid. The invention does not rely on flocculation, sedimentation, centrifugation, the buoyancy of the materials, or any other gravity dependent characteristic, in order to achieve its desired results. The methods of the present invention provide that a first acoustic wave is propagated through a vessel containing the materials. A second acoustic wave, at a frequency different than the first acoustic wave, is also propagated through the vessel so that the two acoustic waves are superimposed upon each other. The superimposition of the two waves creates a beat frequency wave. The beat frequency wave comprises pressure gradients dividing regions of maximum and minimum pressure. The pressure gradients and the regions of maximum and minimum pressure move through space and time at a group velocity. The moving pressure gradients and regions of maximum and minimum pressure act upon the materials so as to move one of the materials towards a predetermined location in the vessel. The present invention provides that the materials may be controllably moved toward a location, aggregated at a particular location, or physically separated from each other.

  18. Methods and apparatus for moving and separating materials exhibiting different physical properties

    DOEpatents

    Peterson, Stephen C.; Brimhall, Owen D.; McLaughlin, Thomas J.; Baker, Charles D.; Sparks, Sam L.

    1988-01-01

    Methods and apparatus for controlling the movement of materials having different physical properties when one of the materials is a fluid. The invention does not rely on flocculation, sedimentation, centrifugation, the buoyancy of the materials, or any other gravity dependent characteristic, in order to achieve its desired results. The methods of the present invention provide that a first acoustic wave is progpagated through a vessel containing the materials. A second acoustic wave, at a frequency different than the first acoustic wave, is also propagated through the vessel so that the two acoustic waves are superimposed upon each other. The superimposition of the two waves creates a beat frequency wave. The beat frequency wave comprises pressure gradients dividing regions of maximum and minimum pressure. The pressure gradients and the regions of maximum and minimum pressure move through space and time at a group velocity. The moving pressure gradients and regions of maximum and minimum pressure act upon the marterials so as to move one of the materials towards a predetermined location in the vessel. The present invention provides that the materials may be controllably moved toward a location, aggreated at a particular location, or physically separated from each other.

  19. Developments in GHz-ultrasonic interferometry for elasticity studies in geophysics and materials science: application to diamond

    NASA Astrophysics Data System (ADS)

    Chang, Y.; Jacobsen, S. D.; Holl, C. M.; Bina, C. R.

    2009-12-01

    Elastic properties of solids are fundamentally important in Earth and materials science because they govern seismic wave propagation at the geophysical scale, but are controlled at the atomic scale by the nature of interatomic bonding. GHz-ultrasonic interferometry utilizes thin-film piezoelectric transducers driven by pulse modulated, microwave-range carrier frequencies at 0.5-2.0 GHz to measure sound wave travel times in sub-millimeter sized samples (Spetzler et al. 1993). Travel times are determined from the spacing of interference fringes produced by measuring the amplitude of overlapping echoes scanned in frequency (wavelength) from opposite polished faces of single crystals. The ultrasonic signals are near-optical in wavelength at 5-20 km/s in high-modulus materials, allowing study of samples as small as a few tens of micrometers in thickness, including micro-crystals loaded in diamond-anvil cells at high pressures and temperatures. Following Jacobsen et al. (2004), both longitudinal and shear-wave measurements are possible. Although relative changes in travel time on compression or heating are measured with standard deviation of about 0.02 nanoseconds out of 20-200 ns (depending on sample thickness), the absolute accuracy of ultrasonic measurements at standard conditions, required to anchor high P-T measurements, has been limited by our ability to measure sample thickness mechanically at STP, with only 1-2 micrometer accuracy out of 20-200 μm for typical samples. Thus, we have recently installed a commercial heterodyne optical interferometer to determine ultrasonic sample lengths at STP conditions. Using a double-pass laser interferometer we achieve λ/4 fundamental optical resolution with λ/128 (about 5 nm) system resolution through software-based interpolation. By adding real-time corrections for air temperature, humidity, and pressure applied to the laser wavelength, we achieve high accuracy with standard deviations of about 0.02 micrometers in the thickness measurements. Using this new setup, we determined the C11 and C44 elastic constants of natural type IIA single-crystal diamond with unprecedented precision: C11 = 1076.2(6) GPa and C44 = 575.8(4) GPa, improving the reported uncertainty in moduli of diamond by about one order of magnitude over previous ultrasonic measurements (e.g. McSkimin and Bond 1957). This technique will allow us to ascertain whether or not reported variability in elastic properties various forms of synthetic diamond are significant. We plan to use the instrument to study both natural and synthetic diamond elasticity and variations in equations of state with defect structure and pressure, as well as other superhard materials intended for use in future societal applications.

  20. Specification of absorbed-sound power in the ear canal: Application to suppression of stimulus frequency otoacoustic emissions

    PubMed Central

    Keefe, Douglas H.; Schairer, Kim S.

    2011-01-01

    An insert ear-canal probe including sound source and microphone can deliver a calibrated sound power level to the ear. The aural power absorbed is proportional to the product of mean-squared forward pressure, ear-canal area, and absorbance, in which the sound field is represented using forward (reverse) waves traveling toward (away from) the eardrum. Forward pressure is composed of incident pressure and its multiple internal reflections between eardrum and probe. Based on a database of measurements in normal-hearing adults from 0.22 to 8 kHz, the transfer-function level of forward relative to incident pressure is boosted below 0.7 kHz and within 4 dB above. The level of forward relative to total pressure is maximal close to 4 kHz with wide variability across ears. A spectrally flat incident-pressure level across frequency produces a nearly flat absorbed power level, in contrast to 19 dB changes in pressure level. Calibrating an ear-canal sound source based on absorbed power may be useful in audiological and research applications. Specifying the tip-to-tail level difference of the suppression tuning curve of stimulus frequency otoacoustic emissions in terms of absorbed power reveals increased cochlear gain at 8 kHz relative to the level difference measured using total pressure. PMID:21361437

  1. Wireless Capacitive Pressure Sensor With Directional RF Chip Antenna for High Temperature Environments

    NASA Technical Reports Server (NTRS)

    Scardelletti, M. C.; Jordan, J. L.; Ponchak, G. E.; Zorman, C. A.

    2015-01-01

    This paper presents the design, fabrication and characterization of a wireless capacitive pressure sensor with directional RF chip antenna that is envisioned for the health monitoring of aircraft engines operating in harsh environments. The sensing system is characterized from room temperature (25 C) to 300 C for a pressure range from 0 to 100 psi. The wireless pressure system consists of a Clapp-type oscillator design with a capacitive MEMS pressure sensor located in the LC-tank circuit of the oscillator. Therefore, as the pressure of the aircraft engine changes, so does the output resonant frequency of the sensing system. A chip antenna is integrated to transmit the system output to a receive antenna 10 m away.The design frequency of the wireless pressure sensor is 127 MHz and a 2 increase in resonant frequency over the temperature range of 25 to 300 C from 0 to 100 psi is observed. The phase noise is less than minus 30 dBcHz at the 1 kHz offset and decreases to less than minus 80 dBcHz at 10 kHz over the entire temperature range. The RF radiation patterns for two cuts of the wireless system have been measured and show that the system is highly directional and the MEMS pressure sensor is extremely linear from 0 to 100 psi.

  2. Isolated diastolic hypertension associated risk factors among Chinese in Anhui Province, China.

    PubMed

    Wang, Yanchun; Xing, Fengjun; Liu, Rongjuan; Liu, Li; Zhu, Yu; Wen, Yufeng; Sun, Wenjie; Song, Ziwei

    2015-04-22

    To explore potential risk factors of isolated diastolic hypertension (IDH) among young and middle-aged Chinese. A community-based cross-sectional study was conducted among 338 subjects, aged 25 years and above, using random sampling technique. There were 68 cases of IDH, 46 cases of isolated systolic hypertension (ISH), 89 cases of systolic and diastolic hypertension (SDH), and 135 of subjects with normal blood pressure. Cases and controls were matched on sex by frequency matching. Demographic characteristics, blood pressure and other relevant information were collected. Compared with controls, patients with IDH and ISH had significant higher level of triglyceride, high density lipoprotein, blood glucose and body mass index (BMI) (p < 0.05); while patients with SDH had significantly higher level of total cholesterol, triglyceride, glucose and BMI (p < 0.05). Linear mixed effects model showed that drinking tea, family history of hypertension (FHH), higher blood glucose, triglyceride and low density lipoprotein were related with elevated diastolic blood pressure (DBP) (p < 0.01); HFH, blood glucose, creatinine and BMI have positive effect on systolic blood pressure (SBP) (p < 0.05). Drinking tea, FHH, high levels of triglyceride, high density lipoprotein, blood glucose and BMI are associated with IDH among young and middle-aged Chinese.

  3. Micro-controller based air pressure monitoring instrumentation system using optical fibers as sensor

    NASA Astrophysics Data System (ADS)

    Hazarika, D.; Pegu, D. S.

    2013-03-01

    This paper describes a micro-controller based instrumentation system to monitor air pressure using optical fiber sensors. The principle of macrobending is used to develop the sensor system. The instrumentation system consists of a laser source, a beam splitter, two multi mode optical fibers, two Light Dependent Resistance (LDR) based timer circuits and a AT89S8252 micro-controller. The beam splitter is used to divide the laser beam into two parts and then these two beams are launched into two multi mode fibers. One of the multi mode fibers is used as the sensor fiber and the other one is used as the reference fiber. The use of the reference fiber is to eliminate the environmental effects while measuring the air pressure magnitude. The laser beams from the sensor and reference fibers are applied to two identical LDR based timer circuits. The LDR based timer circuits are interfaced to a micro-controller through its counter pins. The micro-controller samples the frequencies of the timer circuits using its counter-0 and counter-1 and the counter values are then processed to provide the measure of air pressure magnitude.

  4. Laser surface modification of medical grade alloys for reduced heating in a magnetic resonance imaging environment

    NASA Astrophysics Data System (ADS)

    Benafan, O.; Chen, S.-Y.; Kar, A.; Vaidyanathan, R.

    2015-12-01

    Nanoscale surface modification of medical grade metallic alloys was conducted using a neodymium-doped yttrium aluminum garnet laser-based dopant diffusion technique. The objective of this approach was to minimize the induction heating by reducing the absorbed radio frequency field. Such an approach is advantageous in that the dopant is diffused into the alloy and is not susceptible to detachment or spallation as would an externally applied coating, and is expected to not deteriorate the mechanical and electrical properties of the base alloy or device. Experiments were conducted using a controlled environment laser system with the ability to control laser properties (i.e., laser power, spot size, and irradiation time) and dopant characteristics (i.e., temperature, concentration, and pressure). The reflective and transmissive properties of both the doped and untreated samples were measured in a radio frequency (63.86 MHz) magnetic field using a system comprising a high power signal generator, a localized magnetic field source and sensor, and a signal analyzer. The results indicate an increase in the reflectivity of the laser-treated samples compared to untreated samples. The effect of reflectivity on the heating of the alloys is investigated through a mathematical model incorporating Maxwell's equations and heat conduction.

  5. Fluctuation spectra in the NASA Lewis bumpy-torus plasma

    NASA Technical Reports Server (NTRS)

    Singh, C. M.; Krawczonek, W. M.; Roth, J. R.; Hong, J. Y.; Powers, E. J.

    1978-01-01

    The electrostatic potential fluctuation spectrum in the NASA Lewis bumpy-torus plasma was studied with capacitive probes in the low pressure (high impedance) mode and in the high pressure (low impedance) mode. Under different operating conditions, the plasma exhibited electrostatic potential fluctuations (1) at a set of discrete frequencies, (2) at a continuum of frequencies, and (3) as incoherent high-frequency turbulence. The frequencies and azimuthal wave numbers were determined from digitally implemented autopower and cross-power spectra. The azimuthal dispersion characteristics of the unstable waves were examined by varying the electrode voltage, the polarity of the voltage, and the neutral background density at a constant magnetic field strength.

  6. Experimental investigations of driving frequency effect in low-pressure capacitively coupled oxygen discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Jia; Liu, Yong-Xin; Liu, Gang-Hu

    2015-04-14

    The effect of driving frequency on the electron density is investigated in low-pressure capacitively coupled oxygen plasmas by utilizing a floating hairpin probe. The power absorbed by the plasma is investigated and it is found that the power lost in the matching network can reach 50% or higher under certain conditions. The effect of driving frequency on the electron density is studied from two aspects, i.e., constant absorbed power and electrode voltage. In the former case, the electron density increases with the driving frequency increasing from 13.56 to 40.68 MHz and slightly changes depending on the gas pressures with the frequencymore » further increasing to 100 MHz. In the latter case, the electron density rapidly increases when the driving frequency increases from 13.56 to 40.68 MHz, and then decreases with the frequency further increasing to 100 MHz. The electron series resonance is observed at 40.68 MHz and can be attributed to the higher electron density. And the standing wave effect also plays an important role in increasing electron density at 100 MHz and 2.6 Pa.« less

  7. Correction for frequency-dependent hydrophone response to nonlinear pressure waves using complex deconvolution and rarefactional filtering: application with fiber optic hydrophones.

    PubMed

    Wear, Keith; Liu, Yunbo; Gammell, Paul M; Maruvada, Subha; Harris, Gerald R

    2015-01-01

    Nonlinear acoustic signals contain significant energy at many harmonic frequencies. For many applications, the sensitivity (frequency response) of a hydrophone will not be uniform over such a broad spectrum. In a continuation of a previous investigation involving deconvolution methodology, deconvolution (implemented in the frequency domain as an inverse filter computed from frequency-dependent hydrophone sensitivity) was investigated for improvement of accuracy and precision of nonlinear acoustic output measurements. Timedelay spectrometry was used to measure complex sensitivities for 6 fiber-optic hydrophones. The hydrophones were then used to measure a pressure wave with rich harmonic content. Spectral asymmetry between compressional and rarefactional segments was exploited to design filters used in conjunction with deconvolution. Complex deconvolution reduced mean bias (for 6 fiber-optic hydrophones) from 163% to 24% for peak compressional pressure (p+), from 113% to 15% for peak rarefactional pressure (p-), and from 126% to 29% for pulse intensity integral (PII). Complex deconvolution reduced mean coefficient of variation (COV) (for 6 fiber optic hydrophones) from 18% to 11% (p+), 53% to 11% (p-), and 20% to 16% (PII). Deconvolution based on sensitivity magnitude or the minimum phase model also resulted in significant reductions in mean bias and COV of acoustic output parameters but was less effective than direct complex deconvolution for p+ and p-. Therefore, deconvolution with appropriate filtering facilitates reliable nonlinear acoustic output measurements using hydrophones with frequency-dependent sensitivity.

  8. Ultrasonic attenuation and velocity in AS/3501-6 graphite/epoxy fiber composite

    NASA Technical Reports Server (NTRS)

    Williams, J. H., Jr.; Nayebhashemi, H.; Lee, S. S.

    1979-01-01

    The ultrasonic group velocity and attenuation were measured as a function of frequency for longitudinal and shear waves in the epoxy matrix (3501-6) and in the principal directions of the unidirectional graphite/epoxy composite (AS/3501-6). Tests were conducted in the frequency ranges 0.25 Mz to 14 MHz and 0.5 Mz to 3 MHz for longitudinal and shear wave modes, respectively. The attenuation increased with frequency for all wave modes, but the group velocity was independent of frequency for all wave modes. The effects of pressure and couplant at the transducer-specimen interface were studied and it was found that for each transducer type there exists a frequency dependent 'saturation pressure' corresponding to the maximum output signal amplitude.

  9. Rheology of U-Shaped Granular Particles

    NASA Astrophysics Data System (ADS)

    Hill, Matthew; Franklin, Scott

    We study the response of cylindrical samples of U-shaped granular particles (staples) to extensional loads. Samples elongate in discrete bursts (events) corresponding to particles rearranging and re-entangling. Previous research on samples of constant cross-sectional area found a Weibullian weakest-link theory could explain the distribution of yield points. We now vary the cross-sectional area, and find that the maximum yield pressure (force/area) is a function of particle number density and independent of area. The probability distribution function of important event characteristics -- the stress increase before an event and stress released during an event -- both fall of inversely with magnitude, reminiscent of avalanche dynamics. Fourier transforms of the fluctuating force (or stress) scales inversely with frequency, suggesting dry friction plays a role in the rearrangements. Finally, there is some evidence that dynamics are sensitive to the stiffness of the tensile testing machine, although an explanation for this behavior is unknown.

  10. Ultrafast Dynamic Pressure Sensors Based on Graphene Hybrid Structure.

    PubMed

    Liu, Shanbiao; Wu, Xing; Zhang, Dongdong; Guo, Congwei; Wang, Peng; Hu, Weida; Li, Xinming; Zhou, Xiaofeng; Xu, Hejun; Luo, Chen; Zhang, Jian; Chu, Junhao

    2017-07-19

    Mechanical flexible electronic skin has been focused on sensing various physical parameters, such as pressure and temperature. The studies of material design and array-accessible devices are the building blocks of strain sensors for subtle pressure sensing. Here, we report a new and facile preparation of a graphene hybrid structure with an ultrafast dynamic pressure response. Graphene oxide nanosheets are used as a surfactant to prevent graphene restacking in aqueous solution. This graphene hybrid structure exhibits a frequency-independent pressure resistive sensing property. Exceeding natural skin, such pressure sensors, can provide transient responses from static up to 10 000 Hz dynamic frequencies. Integrated by the controlling system, the array-accessible sensors can manipulate a robot arm and self-rectify the temperature of a heating blanket. This may pave a path toward the future application of graphene-based wearable electronics.

  11. Microwave fluid flow meter

    DOEpatents

    Billeter, Thomas R.; Philipp, Lee D.; Schemmel, Richard R.

    1976-01-01

    A microwave fluid flow meter is described utilizing two spaced microwave sensors positioned along a fluid flow path. Each sensor includes a microwave cavity having a frequency of resonance dependent upon the static pressure of the fluid at the sensor locations. The resonant response of each cavity with respect to a variation in pressure of the monitored fluid is represented by a corresponding electrical output which can be calibrated into a direct pressure reading. The pressure drop between sensor locations is then correlated as a measure of fluid velocity. In the preferred embodiment the individual sensor cavities are strategically positioned outside the path of fluid flow and are designed to resonate in two distinct frequency modes yielding a measure of temperature as well as pressure. The temperature response can then be used in correcting for pressure responses of the microwave cavity encountered due to temperature fluctuations.

  12. Frequency of early vascular aging and associated risk factors among an adult population in Latin America: the OPTIMO study.

    PubMed

    Botto, Fernando; Obregon, Sebastian; Rubinstein, Fernando; Scuteri, Angelo; Nilsson, Peter M; Kotliar, Carol

    2018-03-01

    The main objective was to estimate the frequency of early vascular aging (EVA) in a sample of subjects from Latin America, with emphasis in young adults. We included 1416 subjects from 12 countries in Latin America who provided information about lifestyle, cardiovascular risk factors (CVRF), and anthropometrics. We measured pulse wave velocity (PWV) as a marker of arterial stiffness, and blood pressure (BP) using an oscillometric device (Mobil-O-Graph). To determine the frequency of EVA, we used multiple linear regression to estimate each subject's PWV expected for his/her age and systolic BP, and compared with observed values to obtain standardized residuals (z-scores). We defined EVA when z-score was ≥1.96. Finally, a multivariable logistic regression analysis was performed to determine baseline characteristics associated with EVA. Mean age was 49.9 ± 15.5 years, male gender was 50.3%. Mean PWV was 7.52 m/s (SD 1.97), mean systolic BP was 125.3 mmHg (SD 16.7) and mean diastolic BP was 78.9 mmHg (SD 12.2). The frequency of EVA was 5.7% in the total population, 9.8% in adults of 40 years or less and 18.7% in those 30 years or less. In these young adults, multiple logistic regression analyses demonstrated that dyslipidemia and hypertension showed an independent association with EVA, and smoking a borderline association (p  =  0.07). In conclusion, the frequency of EVA in a sample from Latin America was around 6%, with higher rates in young adults. These results would support the search of CVRF and EVA during early adulthood.

  13. Experimental validation of damping properties and solar pressure effects on flexible, high area-to-mass ratio debris model

    NASA Astrophysics Data System (ADS)

    Channumsin, Sittiporn; Ceriotti, Matteo; Radice, Gianmarco; Watson, Ian

    2017-09-01

    Multilayer insulation (MLI) is a recently-discovered type of debris originating from delamination of aging spacecraft; it is mostly detected near the geosynchronous orbit (GEO). Observation data indicates that these objects are characterised by high reflectivity, high area-to-mass ratio (HAMR), fast rotation, high sensitivity to perturbations (especially solar radiation pressure) and change of area-to-mass ratio (AMR) over time. As a result, traditional models (e.g. cannonball) are unsuitable to represent and predict this debris' orbital evolution. Previous work by the authors effectively modelled the flexible debris by means of multibody dynamics to improve the prediction accuracy. The orbit evolution with the flexible model resulted significantly different from using the rigid model. This paper aims to present a methodology to determine the dynamic properties of thin membranes with the purpose to validate the deformation characteristics of the flexible model. A high-vacuum chamber (10-4 mbar) to significantly decrease air friction, inside which a thin membrane is hinged at one end but free at the other provides the experimental setup. A free motion test is used to determine the damping characteristics and natural frequency of the thin membrane via logarithmic decrement and frequency response. The membrane can swing freely in the chamber and the motion is tracked by a static, optical camera, and a Kalman filter technique is implemented in the tracking algorithm to reduce noise and increase the tracking accuracy of the oscillating motion. Then, the effect of solar radiation pressure on the thin membrane is investigated: a high power spotlight (500-2000 W) is used to illuminate the sample and any displacement of the membrane is measured by means of a high-resolution laser sensor. Analytic methods from the natural frequency response and Finite Element Analysis (FEA) including multibody simulations of both experimental setups are used for the validation of the flexible model by comparing the experimental results of amplitude decay, natural frequencies and deformation. The experimental results show good agreement with both analytical results and finite element methods.

  14. [Special artificial respiration procedures and intracranial pressure. Animal experiment studies, development and use of a new pressure measuring technic, clinical aspects].

    PubMed

    Schedl, R

    1985-01-01

    We investigated the influence of Forced Diffusion Ventilation (FDV), a special form of High Frequency Ventilation (HFV), on elevated intracranial pressure (ICP) in 5 dogs. Elevation of ICP was standardized by inflation of an epidural balloon. A typical finding with FDV is a reduced intrapleural pressure and therefore one could expect a better cerebrovenous drainage influencing ICP. Nevertheless, we found no changes in mean ICP under conditions of FDV compared with IPPV. Respirator-synchronous fluctuations of ICP, cisternal cerebrospinal fluid pressure and intrapleural pressure were drastically reduced with FDV. This phenomenon has been already reported by other groups as a typical effect of HFV with rates of 100/min. One can speculate, that this immediate impact of HFV on ICP-curves might be of some advantage in patients with critically reduced intracranial compliance requiring long-term artificial ventilation, because peaks and amplitudes of ICP are reduced. Our clinical experience with High Frequency Pulsation (HFP) includes 11 patients with severe brain trauma. In clinical routine this method of HFV is more facile to applicate than FDV, because there is no need of a special endotracheal tube and sufficient CO2-elimination is not strongly dependent on precise position of the tube. But HFP, as FDV, includes all advantages of respiratory systems, that are open against atmosphere (coughing and simultaneous breathing, without drastically increasing airway pressure, suction during respiration, etc.). However, we could find no special advantages or disadvantages in ICP-course during long-term application of HFP (up to 10 days). Because application of HFV is dependent on special technical equipment, we investigated in 6 patients the influence of respiratory frequency, tidal volume and inspiratory flow on ICP-fluctuations using conventional ventilators. ICP was recorded by a new, self constructed pneumatic epidural pressure sensor. Ventilator-related ICP-fluctuations were found to be markedly reduced at frequencies of 20/min and usually eliminated at 30/min. We found an exponential correlation between ICP-fluctuations and respiratory frequency and there was no correlation between tidal volume and ICP. Central venous pressure amplitudes were found to be in linear correlation with respiratory frequency and tidal volumes as well. The amplitude of respiratory ICP-fluctuations seems to be more dependent on duration of expiratory time. As our findings demonstrate, artificial ventilation without entilator-related fluctuations in ICP ("brain-protective" ventilation) may be performed by conventional volume-constant, time-cycled ventilators.(ABSTRACT TRUNCATED AT 400 WORDS)

  15. Frequency response of nonlinear oscillations of air column in a tube with an array of Helmholtz resonators.

    PubMed

    Sugimoto, N; Masuda, M; Hashiguchi, T

    2003-10-01

    Nonlinear cubic theory is developed to obtain a frequency response of shock-free, forced oscillations of an air column in a closed tube with an array of Helmholtz resonators connected axially. The column is assumed to be driven by a plane piston sinusoidally at a frequency close or equal to the lowest resonance frequency with its maximum displacement fixed. By applying the method of multiple scales, the equation for temporal modulation of a complex pressure amplitude of the lowest mode is derived in a case that a typical acoustic Mach number is comparable with the one-third power of the piston Mach number, while the relative detuning of a frequency is comparable with the quadratic order of the acoustic Mach number. The steady-state solution gives the asymmetric frequency response curve with bending (skew) due to nonlinear frequency upshift in addition to the linear downshift. Validity of the theory is checked against the frequency response obtained experimentally. For high amplitude of oscillations, an effect of jet loss at the throat of the resonator is taken into account, which introduces the quadratic loss to suppress the peak amplitude. It is revealed that as far as the present check is concerned, the weakly nonlinear theory can give quantitatively adequate description up to the pressure amplitude of about 3% to the equilibrium pressure.

  16. Design of a Cyclic Pressure Bioreactor for the Ex Vivo Study of Aortic Heart Valves

    PubMed Central

    Schipke, Kimberly J.; Filip To, S. D.; Warnock, James N.

    2011-01-01

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage1-3. Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease4. The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve5. Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves6-9. Pulsatile bioreactors have also been developed to study a range of tissues including cartilage10, bone11 and bladder12. The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed air into the system at the appropriate rate. The system mimicked the dynamic transvalvular pressure levels associated with the aortic valve; a saw tooth wave produced a gradual increase in pressure, typical of the transvalvular pressure gradient that is present across the valve during diastole, followed by a sharp pressure drop depicting valve opening in systole. The LabVIEW program allowed users to control the magnitude and frequency of cyclic pressure. The system was able to subject tissue samples to physiological and pathological pressure conditions. This device can be used to increase our understanding of how heart valves respond to changes in the local mechanical environment. PMID:21876532

  17. Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.

    PubMed

    Schipke, Kimberly J; To, S D Filip; Warnock, James N

    2011-08-23

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage(1-3). Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease(4). The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve(5). Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves(6-9). Pulsatile bioreactors have also been developed to study a range of tissues including cartilage(10), bone(11) and bladder(12). The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed air into the system at the appropriate rate. The system mimicked the dynamic transvalvular pressure levels associated with the aortic valve; a saw tooth wave produced a gradual increase in pressure, typical of the transvalvular pressure gradient that is present across the valve during diastole, followed by a sharp pressure drop depicting valve opening in systole. The LabVIEW program allowed users to control the magnitude and frequency of cyclic pressure. The system was able to subject tissue samples to physiological and pathological pressure conditions. This device can be used to increase our understanding of how heart valves respond to changes in the local mechanical environment.

  18. Fluid mechanical model of the Helmholtz resonator

    NASA Technical Reports Server (NTRS)

    Hersh, A. S.; Walker, B.

    1977-01-01

    A semi-empirical fluid mechanical model of the acoustic behavior of Helmholtz resonators is presented which predicts impedance as a function of the amplitude and frequency of the incident sound pressure field and resonator geometry. The model assumes that the particle velocity approaches the orifice in a spherical manner. The incident and cavity sound fields are connected by solving the governing oscillating mass and momentum conservation equations. The model is in agreement with the Rayleigh slug-mass model at low values of incident sound pressure level. At high values, resistance is predicted to be independent of frequency, proportional to the square root of the amplitude of the incident sound pressure field, and virtually independent of resonator geometry. Reactance is predicted to depend in a very complicated way upon resonator geometry, incident sound pressure level, and frequency. Nondimensional parameters are defined that divide resonator impedance into three categories corresponding to low, moderately low, and intense incident sound pressure amplitudes. The two-microphone method was used to measure the impedance of a variety of resonators. The data were used to refine and verify the model.

  19. Flow Glottogram Characteristics and Perceived Degree of Phonatory Pressedness.

    PubMed

    Millgård, Moa; Fors, Tobias; Sundberg, Johan

    2016-05-01

    Phonatory pressedness is a clinically relevant aspect of voice, which generally is analyzed by auditory perception. The present investigation aimed at identifying voice source and formant characteristics related to experts' ratings of phonatory pressedness. Experimental study of the relations between visual analog scale ratings of phonatory pressedness and voice source parameters in healthy voices. Audio, electroglottogram, and subglottal pressure, estimated from oral pressure during /p/ occlusion, were recorded from five female and six male subjects, each of whom deliberately varied phonation type between neutral, flow, and pressed in the syllable /pae/, produced at three loudness levels and three pitches. Speech-language pathologists rated, along a visual analog scale, the degree of perceived phonatory pressedness in these samples. The samples were analyzed by means of inverse filtering with regard to closed quotient, dominance of the voice source fundamental, normalized amplitude quotient, peak-to-peak flow amplitude, as well as formant frequencies and the alpha ratio of spectrum energy above and below 1000 Hz. The results were compared with the rating data, which showed that the ratings were closely related to voice source parameters. Approximately, 70% of the variance of the ratings could be explained by the voice source parameters. A multiple linear regression analysis suggested that perceived phonatory pressedness is related most closely to subglottal pressure, closed quotient, and the two lowest formants. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. Low-frequency absorption of sound in air

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.; Meredith, R. W.

    1985-01-01

    Thirty sets of sound absorption measurements in air at a pressure of 1 atmosphere are presented at temperatures from 10 C to 50 C, relative humidities from 0 to 100 percent, and frequencies from 10 to 2500 Hz. The measurements were conducted by the method of free decay in a resonant tube having a length of 18.261 m and bore diameter of 0.152 m. Background measurements in a gas consisting of 89.5 percent N2 and 10.5 percent Ar, a mixture which has the same sound velocity as air, permitted the wall and structural losses of the tube to be separated from the constituent absorption, consisting of classical rotational and vibrational absorption, in the air samples. The data were used to evaluate the vibrational relaxation frequencies of N2 and/or O2 for each of the 30 sets of meteorological parameters. Over the full range of humidity, the measured relaxation frequencies of N2 in air lie between those specified by ANSI Standard S1.26-1978 and those measured earlier in binary N2H2O mixtures. The measured relaxation frequencies could be determined only at very low values of humidity, reveal a significant trend away from the ANSI standard, in agreement with a prior investigation.

  1. Low-frequency sound absorption measurements in air

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.; Meredith, R. W.

    1984-01-01

    Thirty sets of sound absorption measurements in air at a pressure of 1 atmosphere are presented at temperatures from 10 C to 50 C, relative humidities from 0 to 100 percent, and frequencies from 10 to 2500 Hz. The measurements were conducted by the method of free decay in a resonant tube having a length of 18.261 m and bore diameter of 0.152 m. Background measurements in a gas consisting of 89.5 percent N2 and 10.5 percent Ar, a mixture which has the same sound velocity as air, permitted the wall and structural losses of the tube to be separated from the constituent absorption, consisting of classical rotational and vibrational absorption, in the air samples. The data were used to evaluate the vibrational relaxation frequencies of N2 and/or O2 for each of the 30 sets of meteorological parameters. Over the full range of humidity, the measured relaxation frequencies of N2 in air lie between those specified by ANSI Standard S1.26-1978 and those measured earlier in binary N2H2O mixtures. The measured relaxation frequencies could be determined only at very low values of humidity, reveal a significant trend away from the ANSI standard, in agreement with a prior investigation.

  2. Oxygen partial pressure effects on the RF sputtered p-type NiO hydrogen gas sensors

    NASA Astrophysics Data System (ADS)

    Turgut, Erdal; Çoban, Ömer; Sarıtaş, Sevda; Tüzemen, Sebahattin; Yıldırım, Muhammet; Gür, Emre

    2018-03-01

    NiO thin films were grown by Radio Frequency (RF) Magnetron Sputtering method under different oxygen partial pressures, which are 0.6 mTorr, 1.3 mTorr and 2.0 mTorr. The effects of oxygen partial pressures on the thin films were analyzed through Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), X-ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS) and Hall measurements. The change in the surface morphology of the thin films has been observed with the SEM and AFM measurements. While nano-pyramids have been obtained on the thin film grown at the lowest oxygen partial pressure, the spherical granules lower than 60 nm in size has been observed for the samples grown at higher oxygen partial pressures. The shift in the dominant XRD peak is realized to the lower two theta angle with increasing the oxygen partial pressures. XPS measurements showed that the Ni2p peak involves satellite peaks and two oxidation states of Ni, Ni2+ and Ni3+, have been existed together with the corresponding splitting in O1s spectrum. P-type conductivity of the grown NiO thin films are confirmed by the Hall measurements with concentrations on the order of 1013 holes/cm-3. Gas sensor measurements revealed minimum of 10% response to the 10 ppm H2 level. Enhanced responsivity of the gas sensor devices of NiO thin films is shown as the oxygen partial pressure increases.

  3. Do agonistic motives matter more than anger? Three studies of cardiovascular risk in adolescents.

    PubMed

    Ewart, Craig K; Elder, Gavin J; Smyth, Joshua M; Sliwinski, Martin J; Jorgensen, Randall S

    2011-09-01

    Three motivational profiles have been associated with recurring psychological stress in low-income youth and young adults: Striving to control others (agonistic striving), striving to control the self (transcendence striving), and not asserting control (dissipated striving). Agonistic striving has been associated with elevated ambulatory blood pressure during daily activities. Three studies tested the hypotheses that: (1) agonistic striving is associated with poor anger regulation, and (2) agonistic striving and poor anger regulation interactively elevate blood pressure. Motivational profiles, anger regulation, and ambulatory blood pressure were assessed in a multiethnic sample of 264 urban youth. (1) anger regulation/recovery during laboratory challenge; (2) anger/blood pressure during daily activities (48 hours). Replication of the profiles in distant cities showed they occur with similar frequency across differences of region, race, and gender. Analyses controlling for body size, race, and gender revealed that individuals with the agonistic striving profile had higher ambulatory pressure, especially during social encounters. They became more openly angry and aggressive when challenged but did not exhibit difficulty regulating anger in the laboratory, nor did they feel angrier during monitoring. However, individuals with the agonistic striving profile who did display poor anger regulation in the lab had the highest blood pressure; deficient self-regulatory capability amplified the positive association between agonistic striving and cardiovascular risk in both genders and all ethnic groups. Although anger is thought to increase cardiovascular risk, present findings suggest that anger and elevated blood pressure are coeffects of agonistic struggles to control others.

  4. On the upper part load vortex rope in Francis turbine: Experimental investigation

    NASA Astrophysics Data System (ADS)

    Nicolet, C.; Zobeiri, A.; Maruzewski, P.; Avellan, F.

    2010-08-01

    The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.

  5. Surface pressure fluctuations in hypersonic turbulent boundary layers

    NASA Technical Reports Server (NTRS)

    Raman, K. R.

    1974-01-01

    The surface pressure fluctuations on a flat plate model at hypersonic Mach numbers of 5.2, 7.4 and 10.4 with an attached turbulent boundary layer were measured using flush mounted small piezoelectric sensors. A high frequency resolution of the pressure field was achieved using specially designed small piezoelectric sensors that had a good frequency response well above 300 KHz. The RMS pressures and non-dimensional energy spectra for all above Mach numbers are presented. The convective velocities, obtained from space time correlation considerations are equal to 0.7 U sub infinity. The results indicate the RMS pressures vary from 5 to 25 percent of the mean static pressures. The ratios of RMS pressure to dynamic pressure are less than the universally accepted subsonic value of 6 x 10/3. The ratio decreases in value as the Mach number or the dynamic pressure is increased. The ratio of RMS pressure to wall shear for Mach number 7.4 satisfies one smaller than or equal to p/tau sub w smaller than or equal to three.

  6. Nonlinear aspects of infrasonic pressure transfer into the perilymph.

    PubMed

    Krukowski, B; Carlborg, B; Densert, O

    1980-06-01

    The perilymphatic pressure was studied in response to various low frequency pressure changes in the ear canal. The pressure transfer was analysed and found to be nonlinear in many aspects. The pressure response was found to contain two time constants representing the inner ear pressure regulating mechanisms. The time constants showed an asymmetry in response to positive and negative going inputs--the effects to some extent proportional to input levels. Further nonlinearities were found when infrasonic sine waves were applied to the ear. Harmonic distortion and modulation appeared. When short bursts of infrasound were introduced a clear d.c. shift was observed as a consequence of an asymmetry in the response to positive and negative going pressure inputs. A temporary change in mean perilymphatic pressure was thus achieved and continued throughout the duration of the signal. At very low frequencies a distinct phase shift was detected in the sine waves. This appeared as a phase lead, breaking the continuity of the output sine wave.

  7. Validation of a new micro-manometer pressure sensor for cardiovascular measurements in mice.

    PubMed

    Trevino, Rodolfo J; Jones, Douglas L; Escobedo, Daniel; Porterfield, John; Larson, Erik; Chisholm, Gary B; Barton, Amanda; Feldman, Marc D

    2010-01-01

    Abstract The Scisense (London, ON, Canada) micro-manometer pressure sensor is currently being used by investigators to evaluate cardiovascular physiology in mice, but has not been validated to date. The purpose of the current study is to compare the 1.2 F Scisense pressure sensor to the current gold standard produced by Millar Instruments (Houston, TX) (1.4 F). In vitro comparisons were preformed including temperature drift, frequency response analysis up to 250 Hz, and damping coefficient and natural frequency determined via a pop test. The authors also performed in vivo comparisons including pressure drift, dose-response studies to IV isoproterenol, maximum adrenergic stimulation with IV dobutamine, and simultaneous placement of both micro-manometer pressure sensors in the same intact murine hearts. The authors conclude that both sensors are equivalent, and that the Scisense pressure sensor represents an alternative to the current gold standard, the Millar micro-manometer pressure sensor for in vivo pressure measurements in the mouse.

  8. Modes of elastic plates and shells in water driven by modulated radiation pressure of focused ultrasound

    NASA Astrophysics Data System (ADS)

    Marston, Philip L.; Daniel, Timothy D.; Abawi, Ahmad T.; Kirsteins, Ivars

    2015-11-01

    The modulated radiation pressure (MRP) of ultrasound has been used for decades to selectively excite low frequency modes associated with surface tension of fluid objects in water. Much less is known about the excitation of low frequency modes of less compliant metallic objects. Here we use MRP of focused ultrasound to excite resonant flexural vibrations of a circular metal plate in water. The source transducer was driven with a double-sideband suppressed carrier voltage as in. The response of the target (detected with a hydrophone) was at twice the modulation frequency and proportional to the square of the drive voltage. Since the radiation pressure of focused beams is spatially localized, mode shapes could be identified by scanning the source along the target while measuring the target's response. Additional measurements were done with an open-ended water-filled copper circular cylindrical shell in which resonant frequencies and mode shapes were also identified. These experiments show how focused ultrasound can be used to identify low-frequency modes of elastic objects without direct contact. Supported by ONR.

  9. Investigation of Noise Field and Velocity Profiles of an Afterburning Engine

    NASA Technical Reports Server (NTRS)

    North, Warren J.; Callaghan, E. E.; Lanzo, C. D.

    1954-01-01

    Sound pressure levels, frequency spectrum, and jet velocity profiles are presented for an engine-afterburner combination at various values of afterburner fuel - air ratio. At the high fuel-air ratios, severe low-frequency resonance was encountered which represented more than half the total energy in the sound spectrum. At similar thrust conditions, lower sound pressure levels were obtained from a current fighter air craft with a different afterburner configuration. The lower sound pressure levels are attributed to resonance-free afterburner operation and thereby indicate the importance of acoustic considerations in afterburner design.

  10. Compressibility effects on rotor forces in the leakage path between a shrouded pump impeller and its housing

    NASA Technical Reports Server (NTRS)

    Cao, Nhai The

    1993-01-01

    A modified approach to Childs' previous work on fluid-structure interaction forces in the leakage path between an impeller shroud and its housing is presented in this paper. Three governing equations consisting of continuity, path-momentum, and circumferential-momentum equations were developed to describe the leakage path inside a pump impeller. Radial displacement perturbations were used to solve for radial and circumferential force coefficients. In addition, impeller-discharge pressure disturbances were used to obtain pressure oscillation responses due to precessing impeller pressure wave pattern. Childs' model was modified from an incompressible model to a compressible barotropic-fluid model (the density of the working fluid is a function of the pressure and a constant temperature only). Results obtained from this model yielded interaction forces for radial and circumferential force coefficients. Radial and circumferential forces define reaction forces within the impeller leakage path. An acoustic model for the same leakage path was also developed. The convective, Coriolis, and centrifugal acceleration terms are removed from the compressible model to obtain the acoustics model. A solution due to impeller discharge pressure disturbances model was also developed for the compressible and acoustics models. The results from these modifications are used to determine what effects additional perturbation terms in the compressible model have on the acoustic model. The results show that the additional fluid mechanics terms in the compressible model cause resonances (peaks) in the force coefficient response curves. However, these peaks only occurred at high values of inlet circumferential velocity ratios greater than 0.7. The peak pressure oscillation was shown to occur at the wearing ring seal. Introduction of impeller discharge disturbances with n = 11 diametral nodes showed that maximum peak pressure oscillations occurred at nondimensional precession frequencies of f = 6.4 and f = 7.8 for this particular pump. Bolleter's results suggest that for peak pressure oscillations to occur at the wearing ring seal, the nondimensional excitation frequency should be on the order of f = 2.182 for n = 11. The resonances found in this research do not match the excitation frequencies predicted by Bolleter. At the predicted peak excitation frequencies given by Bolleter, the compressible model shows an attenuation of the pressure oscillations at the seal exit. The compressibility of the fluid does not have a significant influence on the model at low values of nondimensional excitation frequency. At high values of nondimensional frequency, the effects of compressibility become more significant. For the acoustic analysis, the convective, Coriolis, and centrifugal acceleration terms do affect the results to a limited extent for precession excitation and to a large extent for a pressure excitation when the fluid operates at relatively high Mach numbers.

  11. Development of a computerized analysis for solid propellant combustion instability with turbulence

    NASA Technical Reports Server (NTRS)

    Chung, T. J.; Park, O. Y.

    1988-01-01

    A multi-dimensional numerical model has been developed for the unsteady state oscillatory combustion of solid propellants subject to acoustic pressure disturbances. Including the gas phase unsteady effects, the assumption of uniform pressure across the flame zone, which has been conventionally used, is relaxed so that a higher frequency response in the long flame of a double-base propellant can be calculated. The formulation is based on a premixed, laminar flame with a one-step overall chemical reaction and the Arrhenius law of decomposition with no condensed phase reaction. In a given geometry, the Galerkin finite element solution shows the strong resonance and damping effect at the lower frequencies, similar to the result of Denison and Baum. Extended studies deal with the higher frequency region where the pressure varies in the flame thickness. The nonlinear system behavior is investigated by carrying out the second order expansion in wave amplitude when the acoustic pressure oscillations are finite in amplitude. Offset in the burning rate shows a negative sign in the whole frequency region considered, and it verifies the experimental results of Price. Finally, the velocity coupling in the two-dimensional model is discussed.

  12. Investigations on the self-excited oscillations in a kerosene spray flame

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de la Cruz Garcia, M.; Mastorakos, E.; Dowling, A.P.

    2009-02-15

    A laboratory scale gas turbine type burner at atmospheric pressure and with air preheat was operated with aviation kerosene Jet-A1 injected from a pressure atomiser. Self-excited oscillations were observed and analysed to understand better the relationship between the spray and thermo-acoustic oscillations. The fluctuations of CH{sup *} chemiluminescence measured simultaneously with the pressure were used to determine the flame transfer function. The Mie scattering technique was used to record spray fluctuations in reacting conditions with a high speed camera. Integrating the Mie intensity over the imaged region gave a temporal signal acquired simultaneously with pressure fluctuations and the transfer functionmore » between the light scattered from the spray and the velocity fluctuations in the plenum was evaluated. Phase Doppler anemometry was used for axial velocity and drop size measurements at different positions downstream the injection plane and for various operating conditions. Pressure spectra showed peaks at a frequency that changed with air mass flow rate. The peak for low air mass flow rate operation was at 220 Hz and was associated with a resonance of the supply plenum. At the same global equivalence ratio but at high air mass flow rates, the pressure spectrum peak was at 323 Hz, a combustion chamber resonant frequency. At low air flow rates, the spray fluctuation motion was pronounced and followed the frequency of the pressure oscillation. At high air flow rates, more effective evaporation resulted in a complete disappearance of droplets at an axial distance of about 1/3 burner diameters from the injection plane, leading to a different flame transfer function and frequency of the self-excited oscillation. The results highlight the sensitivity of the self-excited oscillation to the degree of mixing achieved before the main recirculation zone. (author)« less

  13. Acoustic behavior of Halobacterium salinarum gas vesicles in the high frequency range: experiments and modeling

    PubMed Central

    Cherin, Emmanuel; Melis, Johan M.; Bourdeau, Raymond W.; Yin, Melissa; Kochmann, Dennis M.; Foster, F. Stuart; Shapiro, Mikhail G.

    2017-01-01

    Gas vesicles are a new and unique class of biologically derived ultrasound contrast agents with sub-micron size whose acoustic properties have not been fully elucidated. In this study, we investigated the acoustic collapse pressure and behavior of Halobacterium salinarum gas vesicles at transmit center frequencies ranging from 12.5 to 27.5 MHz. The acoustic collapse pressure was found to be above 550 kPa at all frequencies, 9 fold higher than the critical pressure observed in hydrostatic conditions. We show that gas vesicles behave non-linearly when exposed to ultrasound at incident pressure ranging from 160 kPa to the collapse pressure, and generate second harmonic amplitudes of −2 to −6 dB below the fundamental in media with viscosities ranging from 0.89 to 8 mPa.s. Simulations performed using a Rayleigh-Plesset type model accounting for buckling, and a dynamic finite element analysis, suggest that buckling is the mechanism behind the generation of harmonics. We found good agreement between the level of second harmonic relative to the fundamental measured at 20 MHz and the Rayleigh-Plesset model predictions. Finite element simulations extended these findings to a non-spherical geometry, confirmed that the acoustic buckling pressure corresponds to the critical pressure in hydrostatic conditions, and support the hypothesis of limited gas flow across the GV shell during the compression phase in the frequency range investigated. From simulations, estimates of GV bandwidth-limited scattering indicate that a single GV has a scattering cross-section comparable to that of a red blood cell. These findings will inform the development of GV-based contrast agents and pulse sequences to optimize their detection with ultrasound. PMID:28258771

  14. Pressure-induced emergence of unusually high-frequency transverse excitations in a liquid alkali metal: Evidence of two types of collective excitations contributing to the transverse dynamics at high pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryk, Taras; Lviv Polytechnic National University, 12 S. Bandera Street, UA-79013 Lviv; Ruocco, G.

    Unlike phonons in crystals, the collective excitations in liquids cannot be treated as propagation of harmonic displacements of atoms around stable local energy minima. The viscoelasticity of liquids, reflected in transition from the adiabatic to elastic high-frequency speed of sound and in absence of the long-wavelength transverse excitations, results in dispersions of longitudinal (L) and transverse (T) collective excitations essentially different from the typical phonon ones. Practically, nothing is known about the effect of high pressure on the dispersion of collective excitations in liquids, which causes strong changes in liquid structure. Here dispersions of L and T collective excitations inmore » liquid Li in the range of pressures up to 186 GPa were studied by ab initio simulations. Two methodologies for dispersion calculations were used: direct estimation from the peak positions of the L/T current spectral functions and simulation-based calculations of wavenumber-dependent collective eigenmodes. It is found that at ambient pressure, the longitudinal and transverse dynamics are well separated, while at high pressures, the transverse current spectral functions, density of vibrational states, and dispersions of collective excitations yield evidence of two types of propagating modes that contribute strongly to transverse dynamics. Emergence of the unusually high-frequency transverse modes gives evidence of the breakdown of a regular viscoelastic theory of transverse dynamics, which is based on coupling of a single transverse propagating mode with shear relaxation. The explanation of the observed high-frequency shift above the viscoelastic value is given by the presence of another branch of collective excitations. With the pressure increasing, coupling between the two types of collective excitations is rationalized within a proposed extended viscoelastic model of transverse dynamics.« less

  15. How Internally Coupled Ears Generate Temporal and Amplitude Cues for Sound Localization.

    PubMed

    Vedurmudi, A P; Goulet, J; Christensen-Dalsgaard, J; Young, B A; Williams, R; van Hemmen, J L

    2016-01-15

    In internally coupled ears, displacement of one eardrum creates pressure waves that propagate through air-filled passages in the skull and cause displacement of the opposing eardrum, and conversely. By modeling the membrane, passages, and propagating pressure waves, we show that internally coupled ears generate unique amplitude and temporal cues for sound localization. The magnitudes of both these cues are directionally dependent. The tympanic fundamental frequency segregates a low-frequency regime with constant time-difference magnification from a high-frequency domain with considerable amplitude magnification.

  16. Intelligent telemetric stent for wireless monitoring of intravascular pressure and its in vivo testing.

    PubMed

    Chen, Xing; Brox, Daniel; Assadsangabi, Babak; Hsiang, York; Takahata, Kenichi

    2014-10-01

    This paper reports a sensor-integrated telemetric stent targeted at wireless detection and monitoring of restenosis, a common vascular complication induced by stent implantation. The developed "smart" stent incorporates the design and fabrication approaches that raise the practicality of the device, being tested in an in vivo study that validates its operating principle. The stent is produced to have a gold-coated helical-like structure that serves as a high-performance inductor/antenna and integrated with a novel capacitive pressure sensor chip, all based on medical-grade stainless steel. The stent device forms an inductor-capacitor resonant tank that enables radio-frequency (RF) wireless pressure sensing in an operating frequency range of 30-80 MHz. With an overall length of 20 mm, the device is designed to be compatible with standard balloon catheters and necessary crimping process. The balloon-expanded devices are characterized in saline and blood to determine selective coating of passivation layer, Parylene C, with tailored thicknesses in order to maximize both RF and sensing abilities. In vitro testing of the devices reveals a frequency sensitivity up to 146 ppm/mmHg over a pressure range of 250 mmHg. Tests in pig models show wireless detection of device's resonance and frequency response to variations in local blood pressure, the targeted function of the device.

  17. Study of stator-vane fluctuating pressures in a turbofan engine for static and flight tests

    NASA Technical Reports Server (NTRS)

    Mueller, A. W.

    1984-01-01

    As part of a program to study the fan noise generated from turbofan engines, fluctuating surface pressures induced by fan-rotor wakes were measured on core- and bypass-stator outlet guide vanes of a modified JT15D-1 engine. Tests were conducted with the engine operating on an outdoor test stand and in flight. The amplitudes of pressures measured at fan-rotor blade-passage fundamental frequencies were generally higher and appeared less stable for the static tests than for the flight tests. Fluctuating pressures measured at the blade-passage frequency of the high-speed core compressor were interpreted to be acoustic; however, disturbance trace velocities for either the convected rotor wakes or acoustic pressures were difficult to interpret because of the complex environment.

  18. A Simplified Instrument for Recording and Indicating Frequency and Intensity of Icing Conditions Encountered in Flight

    NASA Technical Reports Server (NTRS)

    Perkins, Porter J; Mccullough, Stuart; Lewis, Ralph D

    1951-01-01

    An instrument for recording and indicating the frequency and intensity of aircraft icing conditions encountered in flight has been developed by the NACA Lewis Laboratory to obtain statistical icing data over world-wide air routes during routine airline operations. The operation of the instrument is based on the creation of a differential pressure between an ice-free total-pressure system and a total-pressure system in which small total-pressure holes vented to static pressure are allowed to plug with ice accretion. The simplicity of this operating principle permits automatic operation, and provides relative freedom from maintenance and operating problems. The complete unit weighing only 18 pounds records icing rate, airspeed, and altitude on photographic film and provides visual indications of icing intensity to the pilot.

  19. On the Accurate Determination of Shock Wave Time-Pressure Profile in the Experimental Models of Blast-Induced Neurotrauma

    PubMed Central

    Skotak, Maciej; Alay, Eren; Chandra, Namas

    2018-01-01

    Measurement issues leading to the acquisition of artifact-free shock wave pressure-time profiles are discussed. We address the importance of in-house sensor calibration and data acquisition sampling rate. Sensor calibration takes into account possible differences between calibration methodology in a manufacturing facility, and those used in the specific laboratory. We found in-house calibration factors of brand new sensors differ by less than 10% from their manufacturer supplied data. Larger differences were noticeable for sensors that have been used for hundreds of experiments and were as high as 30% for sensors close to the end of their useful lifetime. These observations were despite the fact that typical overpressures in our experiments do not exceed 50 psi for sensors that are rated at 1,000 psi maximum pressure. We demonstrate that sampling rate of 1,000 kHz is necessary to capture the correct rise time values, but there were no statistically significant differences between peak overpressure and impulse values for low-intensity shock waves (Mach number <2) at lower rates. We discuss two sources of experimental errors originating from mechanical vibration and electromagnetic interference on the quality of a waveform recorded using state-of-the-art high-frequency pressure sensors. The implementation of preventive measures, pressure acquisition artifacts, and data interpretation with examples, are provided in this paper that will help the community at large to avoid these mistakes. In order to facilitate inter-laboratory data comparison, common reporting standards should be developed by the blast TBI research community. We noticed the majority of published literature on the subject limits reporting to peak overpressure; with much less attention directed toward other important parameters, i.e., duration, impulse, and dynamic pressure. These parameters should be included as a mandatory requirement in publications so the results can be properly compared with others. PMID:29467718

  20. Predominance of Viable Spore-Forming Piezophilic Bacteria in High-Pressure Enrichment Cultures from ~1.5 to 2.4 km-Deep Coal-Bearing Sediments below the Ocean Floor

    PubMed Central

    Fang, Jiasong; Kato, Chiaki; Runko, Gabriella M.; Nogi, Yuichi; Hori, Tomoyuki; Li, Jiangtao; Morono, Yuki; Inagaki, Fumio

    2017-01-01

    Phylogenetically diverse microorganisms have been observed in marine subsurface sediments down to ~2.5 km below the seafloor (kmbsf). However, very little is known about the pressure-adapted and/or pressure-loving microorganisms, the so called piezophiles, in the deep subseafloor biosphere, despite that pressure directly affects microbial physiology, metabolism, and biogeochemical processes of carbon and other elements in situ. In this study, we studied taxonomic compositions of microbial communities in high-pressure incubated sediment, obtained during the Integrated Ocean Drilling Program (IODP) Expedition 337 off the Shimokita Peninsula, Japan. Analysis of 16S rRNA gene-tagged sequences showed that members of spore-forming bacteria within Firmicutes and Actinobacteria were predominantly detected in all enrichment cultures from ~1.5 to 2.4 km-deep sediment samples, followed by members of Proteobacteria, Acidobacteria, and Bacteroidetes according to the sequence frequency. To further study the physiology of the deep subseafloor sedimentary piezophilic bacteria, we isolated and characterized two bacterial strains, 19R1-5 and 29R7-12, from 1.9 and 2.4 km-deep sediment samples, respectively. The isolates were both low G+C content, gram-positive, endospore-forming and facultative anaerobic piezophilic bacteria, closely related to Virgibacillus pantothenticus and Bacillus subtilis within the phylum Firmicutes, respectively. The optimal pressure and temperature conditions for growth were 20 MPa and 42°C for strain 19R1-5, and 10 MPa and 43°C for strain 29R7-12. Bacterial (endo)spores were observed in both the enrichment and pure cultures examined, suggesting that these piezophilic members were derived from microbial communities buried in the ~20 million-year-old coal-bearing sediments after the long-term survival as spores and that the deep biosphere may host more abundant gram-positive spore-forming bacteria and their spores than hitherto recognized. PMID:28220112

  1. Predominance of Viable Spore-Forming Piezophilic Bacteria in High-Pressure Enrichment Cultures from ~1.5 to 2.4 km-Deep Coal-Bearing Sediments below the Ocean Floor.

    PubMed

    Fang, Jiasong; Kato, Chiaki; Runko, Gabriella M; Nogi, Yuichi; Hori, Tomoyuki; Li, Jiangtao; Morono, Yuki; Inagaki, Fumio

    2017-01-01

    Phylogenetically diverse microorganisms have been observed in marine subsurface sediments down to ~2.5 km below the seafloor (kmbsf). However, very little is known about the pressure-adapted and/or pressure-loving microorganisms, the so called piezophiles, in the deep subseafloor biosphere, despite that pressure directly affects microbial physiology, metabolism, and biogeochemical processes of carbon and other elements in situ . In this study, we studied taxonomic compositions of microbial communities in high-pressure incubated sediment, obtained during the Integrated Ocean Drilling Program (IODP) Expedition 337 off the Shimokita Peninsula, Japan. Analysis of 16S rRNA gene-tagged sequences showed that members of spore-forming bacteria within Firmicutes and Actinobacteria were predominantly detected in all enrichment cultures from ~1.5 to 2.4 km-deep sediment samples, followed by members of Proteobacteria, Acidobacteria, and Bacteroidetes according to the sequence frequency. To further study the physiology of the deep subseafloor sedimentary piezophilic bacteria, we isolated and characterized two bacterial strains, 19R1-5 and 29R7-12, from 1.9 and 2.4 km-deep sediment samples, respectively. The isolates were both low G+C content, gram-positive, endospore-forming and facultative anaerobic piezophilic bacteria, closely related to Virgibacillus pantothenticus and Bacillus subtilis within the phylum Firmicutes, respectively. The optimal pressure and temperature conditions for growth were 20 MPa and 42°C for strain 19R1-5, and 10 MPa and 43°C for strain 29R7-12. Bacterial (endo)spores were observed in both the enrichment and pure cultures examined, suggesting that these piezophilic members were derived from microbial communities buried in the ~20 million-year-old coal-bearing sediments after the long-term survival as spores and that the deep biosphere may host more abundant gram-positive spore-forming bacteria and their spores than hitherto recognized.

  2. Total vascular resistance and blood flow frequency during left ventricular assistance using a vibrating flow pump.

    PubMed

    Kobayashi, S; Owada, N; Yambe, T; Nitta, S; Fukuju, T; Hongoh, T; Hashimoto, H

    1999-08-01

    A vibrating flow pump (VFP) can generate high frequency oscillated blood flow within 10-30 Hz by the oscillation of its central tube. A totally implantable artificial heart using a VFP is being developed as a unique type of blood pump. In this study, left ventricular (LV) assist circulation was performed using a VFP. The total vascular resistance and driving frequency of the VFP were estimated from their relationship. The effect of oscillation on the vascular system was studied by the frequency analysis method and vascular impedance. Adult goats were anesthetized by halothane using an inhaler and a left fourth thoracotomy was performed. The inflow cannula was inserted into the left ventricle, and the outflow cannula was sutured to the descending aorta. The VFP and a centrifugal pump were set in parallel for alternation and comparison. The driving frequency of the VFP was changed and included 15, 20, 25, and 30 Hz. The hemodynamic parameters were continuously recorded during experiments by a digital audio tape (DAT) data recorder. The internal pressure of the left ventricular cavity and aortic pressure were monitored by the pressure manometers continuously. One hundred percent LV assistance was judged by the separation of LV and aortic pressure. The total vascular resistance was decreased by the start of operation of each pump. The decrease during flow using the VFP was not as large as that using a centrifugal pump (CP). The arterial input impedance during oscillated blood flow by the VFP showed a slow curve appearance. It was similar to the frequency characteristics curve of natural heart beats within the lower frequencies. The study of arterial impedance may be important for the estimation of the reflection of the pulsatile wave from the arterial branch, among other things.

  3. Experimental observation of the inductive electric field and related plasma nonuniformity in high frequency capacitive discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, S. K.; Chang, H. Y.

    To elucidate plasma nonuniformity in high frequency capacitive discharges, Langmuir probe and B-dot probe measurements were carried out in the radial direction in a cylindrical capacitive discharge driven at 90 MHz with argon pressures of 50 and 400 mTorr. Through the measurements, a significant inductive electric field (i.e., time-varying magnetic field) was observed at the radial edge, and it was found that the inductive electric field creates strong plasma nonuniformity at high pressure operation. The plasma nonuniformity at high pressure operation is physically similar to the E-H mode transition typically observed in inductive discharges. This result agrees well with themore » theories of electromagnetic effects in large area and/or high frequency capacitive discharges.« less

  4. MEMS-based Optic Fiber Fabry-Perot Sensor for Underwater Acoustic Measurement with A Wavelength-switched System

    NASA Astrophysics Data System (ADS)

    Xia, J.; Y Wang, F.; Luo, H.; Hu, Y. M.; Xiong, S. D.

    2017-12-01

    In this paper, a MEMS-based extrinsic Farby-Perot Interferometric (EFPI) acoustic pressure acoustic sensor is presented. The diaphragm structure is used as the second reflected surface, and the sensitive surface to acoustic pressure. A wavelength-switched phase demodulation system for EFPI sensors is used for acoustic signal recovery. The modified phase demodulation system has been demonstrated to recover the signal to a stable intensity fluctuation level of ±0.5 dB at the test frequency of 2000 Hz. In the test depth of 50cm, the sensor has a resonant frequency of 3.7 kHz, a flat frequency range of 10-800Hz, and a corresponding acoustic pressure sensitivity of -159 dB re. 1/μPa.

  5. Pressure changes of volcanic systems derived from seismic signals

    NASA Astrophysics Data System (ADS)

    Neuberg, J. W.; Sturton, S.

    2002-12-01

    Seismic low-frequency events from Soufriere Hills volcano in Montserrat are a superposition of single interface waves travelling along the conduit and leaking into teh volcanic edifice at the upper end of a conduit section where magma properties change rapidly. These low-frequency signals are largely characterised by the intermittency of the interface waves, as well as by the dispersion effects they encounter. Using finite difference modelling of the seismic wavefield together with simultaneous modelling of magma properties in time and at depth, allows us to link the seismic signature directly to magma and conduit parameters. We retrieve a relationship between frequency content of seismic signals and governing pressure in the magma which enables us to determine the pressure changes in the magma from spectral characteristics and their temporal changes.

  6. Data documentation for the bare soil experiment at the University of Arkansas, June - August 1980

    NASA Technical Reports Server (NTRS)

    Sadeghi, A. M.

    1984-01-01

    The primary objective of this study is to evaluate the relationships between soil moisture and reflectivity of a bare soil, using microwave techniques. A drainage experiment was conducted on a Captina silt loam in cooperation with personnel in the Electrical Engineering Department. Measurements included soil moisture pressures at various depths, neutron probe measurements, gravimetric moisture samples, and reflectivity of the soil surface at selected frequencies including 1.5 and 6.0 GHz and at the incident angle of 45 deg. All measurements were made in conjuction with that of reflectivity data.

  7. Venturi Air-Jet Vacuum Ejector For Sampling Air

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Burney, L. Garland; Wade, Larry O.

    1990-01-01

    Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

  8. Characterization of injected aluminum oxide nanoparticle clouds in an rf discharge

    NASA Astrophysics Data System (ADS)

    Krüger, Harald; Killer, Carsten; Schütt, Stefan; Melzer, André

    2018-02-01

    An experimental setup to deagglomerate and insert nanoparticles into a radio frequency discharge has been developed to confine defined aluminum oxide nanoparticles in a dusty plasma. For the confined particle clouds we have measured the spatially resolved in situ size and density distributions. Implementing the whole plasma chamber into the sample volume of an FTIR spectrometer the infrared spectrum of the confined aluminum oxide nanoparticles has been obtained. We have investigated the dependency of the absorbance of the nanoparticles in terms of plasma power, pressure and cloud shape. The particles’ infrared phonon resonance has been identified.

  9. The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure.

    PubMed

    Turianikova, Zuzana; Javorka, Kamil; Baumert, Mathias; Calkovska, Andrea; Javorka, Michal

    2011-09-01

    Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1-10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change.

  10. Elasticity and Anelasticity of Materials from Time-Resolved X-ray Diffraction

    NASA Astrophysics Data System (ADS)

    Sinogeikin, S. V.; Smith, J.; Lin, C.; Bai, L.; Rod, E.; Shen, G.

    2014-12-01

    Recent advances in synchrotron sources, x-ray optics, area detectors, and sample environment control have enabled many time-resolved experimental techniques for studying materials at extreme pressure and temperature conditions. The High Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source has made a sustained effort to develop and assemble a powerful collection of high-pressure apparatus for time-resolved research, and considerable time has been invested in developing techniques for collecting high-quality time-resolved x-ray scattering data. In this talk we will outline recently developed capabilities at HPCAT for studying elasticity and anelasticity of minerals using fast compression and cyclic compression-decompression. A few recent studies will be highlighted. For example, with fast x-ray area detectors having millisecond time resolution, accurate thermal equations of state of materials at temperatures up to 1000K and megabar pressures can be collected in a matter of seconds using membrane-driven diamond anvil cells (DAC), yielding unprecedented time and pressure resolution of true isotherms. Short duration of the experiments eliminates temperature variation during the experiments and in general allows volume measurements at higher pressures and temperatures. Alternatively, high-frequency (kilohertz range) radial diffraction measurements in a panoramic DAC combined with fast, precise cyclic loading/unloading by piezo drive could provide the short time scale necessary for studying rheology of minerals from the elastic response and lattice relaxation as a function of pressure, temperature and strain rate. Finally, we consider some possible future applications for time-resolved high-pressure, high-temperature research of mantle minerals.

  11. Development of high sensitivity eight-element multiplexed fiber laser acoustic pressure hydrophone array and interrogation system

    NASA Astrophysics Data System (ADS)

    Li, Ming; Sun, Zhihui; Zhang, Xiaolei; Li, Shujuan; Song, Zhiqiang; Wang, Meng; Guo, Jian; Ni, Jiasheng; Wang, Chang; Peng, Gangding; Xu, Xiangang

    2017-09-01

    Fiber laser hydrophones have got widespread concerns due to the unique advantages and broad application prospects. In this paper, the research results of the eight-element multiplexed fiber laser acoustic pressure array and the interrogation system are introduced, containing low-noise distributed feedback fiber laser (DFB-FL) fabrication, sensitivity enhancement packaging, and interferometric signal demodulation. The frequency response range of the system is 10Hz-10kHz, the laser frequency acoustic pressure sensitivity reaches 115 dB re Hz/Pa, and the equivalent noise acoustic pressure is less than 60μPa/Hz1/2. The dynamic range of the system is greater than 120 dB.

  12. Intra-arterial pressure measurement in neonates: dynamic response requirements.

    PubMed

    van Genderingen, H R; Gevers, M; Hack, W W

    1995-02-01

    A computer simulation of a catheter manometer system was used to quantify measurement errors in neonatal blood pressure parameters. Accurate intra-arterial pressure recordings of 21 critically ill newborns were fed into this simulated system. The dynamic characteristics, natural frequency and damping coefficient, were varied from 2.5 to 60 Hz and from 0.1 to 1.4, respectively. As a result, errors in systolic, diastolic and pulse arterial pressure were obtained as a function of natural frequency and damping coefficient. Iso-error curves for 2%, 5% and 10% were constructed. Using these curves, the maximum inaccuracy of any neonatal catheter manometer system can be determined and used in the clinical setting.

  13. Design and Operation of a Borehole Straddle Packer for Ground-Water Sampling and Hydraulic Testing of Discrete Intervals at U.S. Air Force Plant 6, Marietta, Georgia

    USGS Publications Warehouse

    Holloway, Owen G.; Waddell, Jonathan P.

    2008-01-01

    A borehole straddle packer was developed and tested by the U.S. Geological Survey to characterize the vertical distribution of contaminants, head, and hydraulic properties in open-borehole wells as part of an ongoing investigation of ground-water contamination at U.S. Air Force Plant 6 (AFP6) in Marietta, Georgia. To better understand contaminant fate and transport in a crystalline bedrock setting and to support remedial activities at AFP6, numerous wells have been constructed that include long open-hole intervals in the crystalline bedrock. These wells can include several discontinuities that produce water, which may contain contaminants. Because of the complexity of ground-water flow and contaminant movement in the crystalline bedrock, it is important to characterize the hydraulic and water-quality characteristics of discrete intervals in these wells. The straddle packer facilitates ground-water sampling and hydraulic testing of discrete intervals, and delivery of fluids including tracer suites and remedial agents into these discontinuities. The straddle packer consists of two inflatable packers, a dual-pump system, a pressure-sensing system, and an aqueous injection system. Tests were conducted to assess the accuracy of the pressure-sensing systems, and water samples were collected for analysis of volatile organic compound (VOCs) concentrations. Pressure-transducer readings matched computed water-column height, with a coefficient of determination of greater than 0.99. The straddle packer incorporates both an air-driven piston pump and a variable-frequency, electronic, submersible pump. Only slight differences were observed between VOC concentrations in samples collected using the two different types of sampling pumps during two sampling events in July and August 2005. A test conducted to assess the effect of stagnation on VOC concentrations in water trapped in the system's pump-tubing reel showed that concentrations were not affected. A comparison was conducted to assess differences between three water-sampling methods - collecting samples from the well by pumping a packer-isolated zone using a submersible pump, by using a grab sampler, and by using a passive diffusion sampler. Concentrations of tetrachloroethylene, trichloroethylene and 1,2-dichloropropane were greatest for samples collected using the submersible pump in the packed-isolated interval, suggesting that the straddle packer yielded the least dilute sample.

  14. Modification of the surface properties of glass-ceramic materials at low-pressure RF plasma stream

    NASA Astrophysics Data System (ADS)

    Tovstopyat, Alexander; Gafarov, Ildar; Galeev, Vadim; Azarova, Valentina; Golyaeva, Anastasia

    2018-05-01

    The surface roughness has a huge effect on the mechanical, optical, and electronic properties of materials. In modern optical systems, the specifications for the surface accuracy and smoothness of substrates are becoming even more stringent. Commercially available pre-polished glass-ceramic substrates were treated with the radio frequency (RF) inductively coupled (13.56 MHz) low-pressure plasma to clean the surface of the samples and decrease the roughness. Optical emission spectroscopy was used to investigate the plasma stream parameters and phase-shifted interferometry to investigate the surface of the specimen. In this work, the dependence of RF inductively coupled plasma on macroscopic parameters was investigated with the focus on improving the surfaces. The ion energy, sputtering rate, and homogeneity were investigated. The improvements of the glass-ceramic surfaces from 2.6 to 2.2 Å root mean square by removing the "waste" after the previous operations had been achieved.

  15. Acoustic cavitation of individual ultrasound contrast agent microbubbles confined in capillaries

    NASA Astrophysics Data System (ADS)

    Almaqwashi, Ali; McIntyre, David; Ammi, Azzdine

    2011-10-01

    Ultrasound targeted therapies mainly rely on the inertial cavitation of ultrasound contrast agent (UCA) microbubbles. Our objective is to determine the cavitation acoustic pressure threshold for the destruction of UCA microbubbles inside cellulose capillaries. Acoustic emission from individual Optison microbubbles confined inside a 200-μm diameter capillary was detected using a passive cavitation detection system. Excitation signals from a 2.25 MHz transmitter were applied to the microbubbles while their acoustic emission was detected by a broadband 15 MHz receiver. Time traces were recorded (100 MHz sampling, 12- bit), and frequency-domain analysis of the received signals was performed to characterize microbubble cavitation. The cavitation acoustic pressure threshold was found to be 1 MPa inside the capillary in comparison with ˜0.7 MPa previously reported for unconfined UCA microbubbles. This work provides a clearer understanding of the role of ultrasound contrast agent dynamics inside a capillary.

  16. Beamforming synthesis of binaural responses from computer simulations of acoustic spaces.

    PubMed

    Poletti, Mark A; Svensson, U Peter

    2008-07-01

    Auditorium designs can be evaluated prior to construction by numerical modeling of the design. High-accuracy numerical modeling produces the sound pressure on a rectangular grid, and subjective assessment of the design requires auralization of the sampled sound field at a desired listener position. This paper investigates the production of binaural outputs from the sound pressure at a selected number of grid points by using a least squares beam forming approach. Low-frequency axisymmetric emulations are derived by assuming a solid sphere model of the head, and a spherical array of 640 microphones is used to emulate ten measured head-related transfer function (HRTF) data sets from the CIPIC database for half the audio bandwidth. The spherical array can produce high-accuracy band-limited emulation of any human subject's measured HRTFs for a fixed listener position by using individual sets of beam forming impulse responses.

  17. Laser Spectroscopy Monitoring of 13C18O16O and 12C17O16O of Atmospheric Carbon Dioxide

    NASA Astrophysics Data System (ADS)

    Shorter, J. H.; Nelson, D. D.; Ono, S.; McManus, J. B.; Zahniser, M. S.

    2017-12-01

    One of the main challenges to making accurate predictions of future changes in CO2 concentration is the capability to determine what fraction of human produced CO2 remains in the atmosphere. We present our progress in the application of Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) to the measurement of the primary clumped (13C18O16O) as well as 17O (12C17O16O) isotopologues of atmospheric CO2, as a tracer of its sources and sinks. We expect unique isotopologue signals in CO2 from high-temperature combustion sources, plants, soils, and air-sea exchange processes. High sampling frequency (a few minutes for each sample vs. reference cycle) achieved by a TILDAS instrument is expected to enable us to document local heterogeneous sources and temporal variations. The TILDAS is equipped with a newly developed 400-meter absorption cell. We designed a dual pressure measurement technique in which the clumped isotopologue, 13C18O16O, and 13C16O16O are first measured at 30 torr cell pressure. This is followed by measurement of 12C17O16O, 12C18O16O and 12C16O16O at lower ( 5 torr) cell pressure. Isotopologue ratios are compared between reference and sample gases. Preliminary tests demonstrated a precision approaching 0.03 ‰ for the ratio 13C18O16O/13C16O16O and 0.08‰ for Δ13C18O16O value (1σ repeatability for 4 min sample vs. reference cycle). Sample size for a single analysis is approximately 100 mL of air (1.6μmol of CO2). Given the previously observed range of variations for Δ13C18O16O and Δ17O values as large as 0.6 to 0.3 ‰, respectively, TILDAS offers a novel approach for real time monitoring of atmospheric CO2 isotopologues. It was found that achieving better than 0.1‰ requires careful matching of CO2 mixing ratios between reference and sample air. A primary cause of pressure and mixing ratio dependence is inaccurate baseline fitting (analogous to abundance sensitivity or pressure baseline for IRMS). Given that mixing ratios of atmospheric CO2 can vary as much as 50% or more, a dynamic dilution scheme, where sample air is diluted by CO2 free air to match the reference mixing ratio, is being developed. An in-line calibration source of hot, equilibrated CO2 isotopologues is also being tested. We will discuss the current instrument performance, areas for improvement, and project future applications.

  18. Measurement of anal pressure and motility.

    PubMed Central

    Hancock, B D

    1976-01-01

    A fine open perfused system and a closed balloon system for the measurement of anal pressure and motility have been compared. Measurements were made in 40 normal subjects and 84 patients with haemorrhoids. The rate of perfusion had a marked effect on the recorded pressure and motility details. The motility pattern was seen most clearly with the balloon probe and the pressure recorded was reproducible and easy to measure, making this a convenient method for recording activity of the internal anal sphincter. Anal motility in normal subjects was characterised by slow pressure waves (10-20/min). The frequency was fastest in the distal anal canal and this frequency gradient may represent a normal mechanism to keep the anal canal empty. Ultra slow pressure waves (0-6-1-9/min) were seen in 42% of patients with haemorrhoids and 5% of normal subjects and arose from a synchronous contraction of the whole internal sphincter. Images Fig. 1 PMID:976803

  19. Demodulation of an optical fiber MEMS pressure sensor based on single bandpass microwave photonic filter.

    PubMed

    Wang, Yiping; Ni, Xiaoqi; Wang, Ming; Cui, Yifeng; Shi, Qingyun

    2017-01-23

    In this paper, a demodulation method for optic fiber micro-electromechanical systems (MEMS) extrinsic Fabry-Perot interferometer (EFPI) pressure sensor exploiting microwave photonics filter technique is firstly proposed and experimentally demonstrated. A single bandpass microwave photonic filter (MPF) which mainly consists of a spectrum-sliced light source, a pressurized optical fiber MEMS EFPI, a phase modulator (PM) and a length of dispersion compensating fiber (DCF) is demonstrated. The frequency response of the filter with respect to the pressure is studied. By detecting the resonance frequency shifts of the MPF, the pressure can be determined. The theoretical and experimental results show that the proposed EFPI pressure demodulation method has a higher resolution and higher speed than traditional methods based on optical spectrum analysis. The sensitivity of the sensor is measured to be as high as 86 MHz/MPa in the range of 0-4Mpa. Moreover, the sensitivity can be easily adjusted.

  20. A dynamic pressure calibration standard

    NASA Technical Reports Server (NTRS)

    Schutte, P. C.; Cate, K. H.; Young, S. D.

    1985-01-01

    A dynamic pressure calibration standard has been developed for calibrating flush diaphragm mounted pressure transducers. Pressures up to 20 kPa (3 psi) have been accurately generated over a frequency range of 50 to 1800 hz. The uncertainty of the standard is +/-5 pct to 5kPa (.75 psi) and +/-10 pct from 5 kPa (.75 psi) to 20 kPa (3 psi). The system consists of two conically shaped, aluminum columns, one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with a viscous fluid. A column is mounted on the armature of a vibration exciter which imparts a sinusoidally varying acceleration to the fluid column. Two pressure transducers mounted at the base of the column sense the sinusoidally varying pressure. This pressure is determined from measurements of the density of the fluid, the height of the fluid, and the acceleration of the column. A section of the taller column is filled with steel balls to control the damping of the fluid to extend its useful frequency range.

Top