Sample records for pressure tubes

  1. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    NASA Astrophysics Data System (ADS)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  2. The effect of cuff presence and cuff inflation on airway pressure in a canine tracheostomy tube model.

    PubMed

    Wignall, Jamie R; Baines, Stephen J

    2014-01-01

    To evaluate the effect of cuff presence and cuff inflation on airway pressure in an inspiratory model of canine tracheostomy. Ex vivo experimental study. Cadaver tracheas from Beagle dogs were attached aborally to a vacuum. Airway pressure and flow rate was measured before and after placement of tracheostomy tubes. None. Adult uncuffed tubes and cuffed tracheostomy tubes (sizes 4, 6, 8, and 10) were placed within tracheas. Cuffs were investigated without inflation and at maximum cuff inflation. Airway pressure was measured at constant airflow rates at 30 and 60 L/min. At set flow rates, airway pressures of tracheostomy tubes were compared to the intact trachea. A size 4 uncuffed tracheostomy tube showed the lowest airway pressure and a size 4 cuffed trachestomy tube with inflation showed the highest airway pressures. For sizes 6, 8, and 10 tubes, the presence of a cuff with and without inflation significantly increased airway pressure. Inflation of a cuff always significantly increased airway pressure. Similar pressure is seen between sizes 4 and 6 uncuffed tubes. Cuffed tracheostomy tubes should not be used unless specifically indicated due to increased airway pressure. © Veterinary Emergency and Critical Care Society 2013.

  3. CHARACTERIZATION OF FLOW-RESISTANT TUBES USED FOR SEMI-OCCLUDED VOCAL TRACT VOICE TRAINING AND THERAPY

    PubMed Central

    Smith, Simeon L.; Titze, Ingo R.

    2016-01-01

    Objectives To characterize the pressure-flow relationship of tubes used for semi-occluded vocal tract voice training/therapy, as well as to answer these major questions: (1) What is the relative importance of tube length to tube diameter? (2) What is the range of oral pressures achieved with tubes at phonation flow rates? (3) Does mouth configuration behind the tubes matter? Methods Plastic tubes of various diameters and lengths were mounted in line with an upstream pipe, and the pressure drop across each tube was measured at stepwise increments in flow rate. Basic flow theory and modified flow theory equations were used to describe the pressure-flow relationship of the tubes based on diameter and length. Additionally, the upstream pipe diameter was varied to explore how mouth shape affects tube resistance. Results The modified equation provided an excellent prediction of the pressure-flow relationship across all tube sizes (6% error compared to the experimental data). Variation in upstream pipe diameter yielded up to 10% deviation in pressure for tube sizes typically used in voice training/therapy. Conclusions Using the presented equations, resistance can be characterized for any tube based on diameter, length, and flow rate. With regard to the original questions, we found that: (1) For commonly used tubes, diameter is the critical variable for governing flow resistance; (2) For phonation flow rates, a range of tube dimensions produced pressures between 0 and 7.0 kPa; (3) The mouth pressure behind the lips will vary slightly with different mouth shapes, but this effect can be considered relatively insignificant. PMID:27133001

  4. 21 CFR 868.5860 - Pressure tubing and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pressure tubing and accessories. 868.5860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5860 Pressure tubing and accessories. (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended to...

  5. Estimating Fluctuating Pressures From Distorted Measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1994-01-01

    Two algorithms extract estimates of time-dependent input (upstream) pressures from outputs of pressure sensors located at downstream ends of pneumatic tubes. Effect deconvolutions that account for distoring effects of tube upon pressure signal. Distortion of pressure measurements by pneumatic tubes also discussed in "Distortion of Pressure Signals in Pneumatic Tubes," (ARC-12868). Varying input pressure estimated from measured time-varying output pressure by one of two deconvolution algorithms that take account of measurement noise. Algorithms based on minimum-covariance (Kalman filtering) theory.

  6. Adapter assembly prevents damage to tubing during high pressure tests

    NASA Technical Reports Server (NTRS)

    Stinett, L. L.

    1965-01-01

    Portable adapter assembly prevents damage to tubing and injury to personnel when pressurizing a system or during high pressure tests. The assembly is capable of withstanding high pressure. It is securely attached to the tubing stub end and may be removed without brazing, cutting or cleaning the tube.

  7. Graphene-based inline pressure sensor integrated with microfluidic elastic tube

    NASA Astrophysics Data System (ADS)

    Inoue, Nagisa; Onoe, Hiroaki

    2018-01-01

    We propose an inline pressure sensor composed of a polydimethylsiloxane (PDMS) microfluidic tube integrated with graphene sheets. The PDMS tube was fabricated through molding, and a multilayered graphene sheet was transferred on the surface of the PDMS tube. The pressure inside the tube was monitored using the changes in the electrical resistance of the transferred graphene. The proposed pressure sensor could be suitable for precise pressure measurement for a small amount of fluid in microfluidic systems including organ-on-a-chip devices.

  8. Sapphire tube pressure vessel

    DOEpatents

    Outwater, John O.

    2000-01-01

    A pressure vessel is provided for observing corrosive fluids at high temperatures and pressures. A transparent Teflon bag contains the corrosive fluid and provides an inert barrier. The Teflon bag is placed within a sapphire tube, which forms a pressure boundary. The tube is received within a pipe including a viewing window. The combination of the Teflon bag, sapphire tube and pipe provides a strong and inert pressure vessel. In an alternative embodiment, tie rods connect together compression fittings at opposite ends of the sapphire tube.

  9. The Bulging Behavior of Thick-Walled 6063 Aluminum Alloy Tubes Under Double-Sided Pressures

    NASA Astrophysics Data System (ADS)

    Cui, Xiao-Lei; Wang, Xiao-Song; Yuan, Shi-Jian

    2015-05-01

    To make further exploration on the deformation behavior of tube under double-sided pressures, the thick-walled 6063 aluminum alloy tubes with an outer diameter of 65 mm and an average thickness of 7.86 mm have been used to be bulged under the combined action of internal and external pressures. In the experiment, two ends of the thick-walled tubes were fixed using the tooth and groove match. Three levels of external pressure (0 MPa, 40 MPa, and 80 MPa), in conjunction with the internal pressure, were applied on the tube outside and inside simultaneously. The effect of external pressure on the bulging behavior of the thick-walled tubes, such as the limiting expansion ratio, the bulging zone profile, and the thickness distribution, has been investigated. It is shown that the limiting expansion ratio, the bulging zone profile, and the thickness distribution in the homogeneous bulging area are all insensitive to the external pressure. However, the external pressure can make the thick-walled tube achieve a thinner wall at the fracture area. It reveals that the external pressure can only improve the fracture limit of the thick-walled 6063 tubes, but it has very little effect on their homogeneous bulging behavior. It might be because the external pressure can only increase the magnitude of the hydrostatic pressure for the tube but has no effect on the Lode parameter.

  10. The structure of untwisted magnetic flux tubes. [solar magnetic field distribution

    NASA Technical Reports Server (NTRS)

    Browning, P. K.; Priest, E. R.

    1982-01-01

    While most previous investigations have concentrated on slender flux tubes, the present study of the equilibrium structure of an axisymmetric magnetic flux tube, confined by an external pressure that varies along the length of the tube, explores the properties of thick tubes in order to establish the degree to which slender tube theory is valid. It is found that slender flux tube results may in some cases give no indication of thick tube behavior in a nonuniform atmosphere. Depending on boundary conditions applied at the ends of the tube, it may expand or contract upon entering a region of increasing pressure. Rather than expanding indefinitely, the tube surface may form a cusped shape when a point of external pressure on the tube surface falls to equality with the internal pressure. Numerical solutions for an initially uniform tube give smaller expansions than would be expected from slender tube theory.

  11. Endotracheal tube leak pressure and tracheal lumen size in swine.

    PubMed

    Finholt, D A; Audenaert, S M; Stirt, J A; Marcella, K L; Frierson, H F; Suddarth, L T; Raphaely, R C

    1986-06-01

    Endotracheal tube "leak" is often estimated in children to judge the fit of uncuffed endotracheal tubes within the trachea. Twenty-five swine were intubated with uncuffed tracheal tubes to determine whether a more sensitive measurement of leaks could be devised and whether leak pressure estimates fit between tracheal tube and trachea. We compared leak pressure measurement using a stethoscope and aneroid manometer with a technique using a microphone, pressure transducer, and recorder, and found no differences between the two methods. The tracheas were then removed and slides prepared of tracheal cross-sectional specimens. Regression analysis revealed a linear relationship between tracheal lumen size and tracheal tube size for both low leak pressure (y = -0.4 + 0.79x, r = 0.88, P less than 0.05) and high leak pressure (y = -2.9 + 0.71x, r = 0.92, P less than 0.05) groups. We conclude that leak testing with a stethoscope and aneroid manometer is sensitive and accurate, and that tracheal tube leak pressure accurately portrays fit between tube and trachea.

  12. Calculation Of Pneumatic Attenuation In Pressure Sensors

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1991-01-01

    Errors caused by attenuation of air-pressure waves in narrow tubes calculated by method based on fundamental equations of flow. Changes in ambient pressure transmitted along narrow tube to sensor. Attenuation of high-frequency components of pressure wave calculated from wave equation derived from Navier-Stokes equations of viscous flow in tube. Developed to understand and compensate for frictional attenuation in narrow tubes used to connect aircraft pressure sensors with pressure taps on affected surfaces.

  13. Strategies to prevent ventilation-associated pneumonia: the effect of cuff pressure monitoring techniques and tracheal tube type on aspiration of subglottic secretions: an in-vitro study.

    PubMed

    Carter, Eleanor L; Duguid, Alasdair; Ercole, Ari; Matta, Basil; Burnstein, Rowan M; Veenith, Tonny

    2014-03-01

    Ventilation-associated pneumonia (VAP) is the commonest nosocomial infection in intensive care. Implementation of a VAP prevention care bundle is a proven method to reduce its incidence. The UK care bundle recommends maintenance of the tracheal tube cuff pressure at 20 to 30  cmH₂O with 4-hourly pressure checks and use of tracheal tubes with subglottic aspiration ports in patients admitted for more than 72  h. To evaluate the effects of tracheal tube type and cuff pressure monitoring technique on leakage of subglottic secretions past the tracheal tube cuff. Bench-top study. Laboratory. A model adult trachea with simulated subglottic secretions was intubated with a tracheal tube with the cuff inflated to 25  cmH₂O. Experiments were conducted using a Portex Profile Soft Seal tracheal tube with three cuff pressure monitoring strategies and using a Portex SACETT tracheal tube with intermittent cuff pressure checks. Rate of simulated secretion leakage past the tracheal tube cuff. Mean ± SD leakage of fluid past the Profile Soft Seal tracheal tube cuff was 2.25 ± 1.49  ml  min⁻¹ with no monitoring of cuff pressure, 2.98 ± 1.63  ml  min⁻¹ with intermittent cuff pressure monitoring and 3.83 ± 2.17  ml  min⁻¹ with continuous cuff pressure monitoring (P <0.001). Using a SACETT tracheal tube with a subglottic aspiration port and aspirating the simulated secretions prior to intermittent cuff pressure checks reduced the leakage rate to 0.50 ± 0.48  ml  min⁻¹ (P <0.001). Subglottic secretions leaked past the tracheal tube cuff with all tube types and cuff pressure monitoring strategies in this model. Significantly higher rates were observed with continuous cuff pressure monitoring and significantly lower rates were observed when using a tracheal tube with a subglottic aspiration port. Further evaluation of medical device performance is needed in order to design more effective VAP prevention strategies.

  14. Tracheostomy Tube Type and Inner Cannula Selection Impact Pressure and Resistance to Air Flow.

    PubMed

    Pryor, Lee N; Baldwin, Claire E; Ward, Elizabeth C; Cornwell, Petrea L; O'Connor, Stephanie N; Chapman, Marianne J; Bersten, Andrew D

    2016-05-01

    Advancements in tracheostomy tube design now provide clinicians with a range of options to facilitate communication for individuals receiving ventilator assistance through a cuffed tube. Little is known about the impact of these modern design features on resistance to air flow. We undertook a bench model test to measure pressure-flow characteristics and resistance of a range of tubes of similar outer diameter, including those enabling subglottic suction and speech. A constant inspiratory ± expiratory air flow was generated at increasing flows up to 150 L/min through each tube (with or without optional, mandatory, or interchangeable inner cannula). Driving pressures were measured, and resistance was calculated (cm H2O/L/s). Pressures changed with increasing flow (P < .001) and tube type (P < .001), with differing patterns of pressure change according to the type of tube (P < .001) and direction of air flow. The single-lumen reference tube encountered the lowest inspiratory and expiratory pressures compared with all double-lumen tubes (P < .001); placement of an optional inner cannula increased bidirectional tube resistance by a factor of 3. For a tube with interchangeable inner cannulas, the type of cannula altered pressure and resistance differently (P < .001); the speech cannula in particular amplified pressure-flow changes and increased tube resistance by more than a factor of 4. Tracheostomy tube type and inner cannula selection imposed differing pressures and resistance to air flow during inspiration and expiration. These differences may be important when selecting airway equipment or when setting parameters for monitoring, particularly for patients receiving supported ventilation or during the weaning process. Copyright © 2016 by Daedalus Enterprises.

  15. Temporal variation of the leak pressure of uncuffed endotracheal tubes following pediatric intubation: an observational study.

    PubMed

    Patel, Shreya; Lalwani, Kirk; Koh, Jeffrey; Wu, Lei; Fu, Rongwei

    2014-06-01

    Uncuffed endotracheal tubes are still preferred over cuffed tubes in certain situations in pediatric anesthesia. Inaccurately sized uncuffed endotracheal tubes may lead to inadequate ventilation or tracheal mucosal damage during anesthesia. Endotracheal tube size in children is usually assessed by measuring the audible leak pressure; if the fit of the tube and the leak pressure decrease significantly with time, reintubation during surgery as a result of inability to ventilate effectively may be challenging, and could lead to patient morbidity. There is no evidence to indicate whether leak pressure increases or decreases with time following endotracheal intubation with uncuffed tubes in children. We measured leak pressure for 30 min following tracheal intubation in 46 ASA I children age 0-7 years after excluding factors known to modify leak pressure. The largest mean change in leak pressure occurred between time points 0 and 15 min, an increase of 3.5 cmH2O. Endotracheal tube size and type of procedure were associated with the leak pressure. In the final linear mixed model, there were no statistically significant variations in leak pressure over time (P = 0.129) in this group of children. We did not identify a consistent change in leak pressure within 30 min following tracheal intubation with uncuffed endotracheal tubes in this group of children.

  16. Flight Investigation of the Effects of Pressure-Belt Tubing Size on Measured Pressure Distributions

    NASA Technical Reports Server (NTRS)

    Rivers, Natale A.; vanDam, Cornielious P.; Brown, Phillip W.; Rivers, Robert A.

    2001-01-01

    The pressure-belt technique is commonly used to measure pressure distributions on lifting and nonlifting surfaces where flush, through-the-surface measurements are not possible. The belts, made from strips of small-bore, flexible plastic tubing, are surface-mounted by a simple, nondestructive method. Additionally, the belts require minimal installation time, thus making them much less costly to install than flush-mounted pressure ports. Although pressure belts have been used in flight research since the early 1950s, only recently have manufacturers begun to produce thinner, more flexible tubing, and thin, strong adhesive tapes that minimize the installation-induced errors on the measurement of surface pressures. The objective of this investigation was to determine the effects of pressure-belt tubing size on the measurement of pressure distributions. For that purpose, two pressure belts were mounted on the right wing of a single-engine, propeller-driven research airplane. The outboard pressure belt served as a baseline for the measurement and the comparison of effects. Each tube had an outer diameter (OD) of 0.0625 in. The inboard belt was used to evaluate three different tube sizes: 0.0625-, 0.1250-, and 0.1875-in. OD. A computational investigation of tube size on pressure distribution also was conducted using the two-dimensional Multielement Streamtube Euler Solver (MSES) code.

  17. Wellbottom fluid implosion treatment system

    DOEpatents

    Brieger, Emmet F.

    2001-01-01

    A system for inducing implosion shock forces on perforation traversing earth formations with fluid pressure where an implosion tool is selected relative to a shut in well pressure and a tubing pressure to have a large and small area piston relationship in a well tool so that at a predetermined tubing pressure the pistons move a sufficient distance to open an implosion valve which permits a sudden release of well fluid pressure into the tubing string and produces an implosion force on the perforations. A pressure gauge on the well tool records tubing pressure and well pressure as a function of time.

  18. [Microcuff pediatric tracheal tube. A new tracheal tube with a high volume-low pressure cuff for children].

    PubMed

    Weiss, M; Dullenkopf, A; Gerber, A C

    2004-01-01

    Principles and characteristics of the recently introduced Microcuff paediatric tracheal tube (Microcuff, GmbH, Weinheim, Germany) with anatomically based depth markings, cuff-free subglottic tube shaft and short high volume-low pressure cuff with ultrathin cuff membrane are presented. First available tubes (ID 4.0 mm) were evaluated regarding cuff pressures required to seal the trachea and regarding the distance from the tube tip to the carina. After obtaining approval of the local ethical committee, 20 children aged 2-4 years, receiving tracheal intubation under general anaesthesia with muscle paralysis, were included. The tubes were placed during direct laryngoscopy and the glottic depth marking placed between the vocal cords. Cuff pressure to prevent audible air leakage at standardised ventilator settings (PIP 20 cm H(2)O/PEEP 5 cm H(2)O/RR20 x min(-1)) was assessed by means of a cuff pressure manometer within 5 min after intubation. Subsequently, the distance from the tube tip to the tracheal carina was measured by means of fibre bronchoscopy. Data are presented as the median (range). Patient age was 3.0 years (2.0-3.9 years), weight 13.5 kg (9.1-19.2 kg) and body length 95 cm (79-105 cm). The lowest cuff pressure required to seal the trachea ranged from 4-14 cmH(2)O (median 10 cm H(2)O), the distance from tube tip to tracheal carina was to 2.9 cm (2.0-4.5 cm). The new Microcuff paediatric tracheal tube with ultrathin high volume-low pressure cuff required tracheal sealing pressures below tracheal wall pressures usually required with uncuffed tracheal tubes for efficient sealing and ventilation at 20 cm H(2)O peak inspiratory pressure. The distance from the tube tip to carina was in the safe range in all patients.

  19. F-16B Pacer Aircraft Trailing Cone Length Extension Tube Investigative Study (HAVE CLETIS)

    DTIC Science & Technology

    2007-06-01

    the axial load experienced during high incompressible dynamic pressures and prevent the coupling from locking up as was observed for the 35-foot... axial loads due to incompressible dynamic pressure. (R4) “Guitar stringing” was used to describe the high frequency vibration of the pressure tube...Modify the design of the pressure tube and drag cone coupling to allow independent pressure tube and drag cone rotation under axial loads due to

  20. Increase of stagnation pressure and enthalpy in shock tunnels

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Cambier, Jean-Luc

    1992-01-01

    High stagnation pressures and enthalpies are required for the testing of aerospace vehicles such as aerospace planes, aeroassist vehicles, and reentry vehicles. Among the most useful ground test facilities for performing such tests are shock tunnels. With a given driver gas condition, the enthalpy and pressure in the driven tube nozzle reservoir condition can be varied by changing the driven tube geometry and initial gas fill pressure. Reducing the driven tube diameter yields only very modest increases in reservoir pressure and enthalpy. Reducing the driven tube initial gas fill pressure can increase the reservoir enthalpy significantly, but at the cost of reduced reservoir pressure and useful test time. A new technique, the insertion of a converging section in the driven tube is found to produce substantial increases in both reservoir pressure and enthalpy. Using a one-dimensional inviscid full kinetics code, a number of different locations and shapes for the converging driven tube section were studied and the best cases found. For these best cases, for driven tube diameter reductions of factors of 2 and 3, the reservoir pressure can be increased by factors of 2.1 and 3.2, respectively and the enthalpy can be increased by factors of 1.5 and 2.1, respectively.

  1. Distortion Of Pressure Signals In Pneumatic Tubes

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William

    1993-01-01

    NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.

  2. Response of the water status of soybean to changes in soil water potentials controlled by the water pressure in microporous tubes.

    PubMed

    Steinberg, S L; Henninger, D L

    1997-12-01

    Water transport through a microporous tube-soil-plant system was investigated by measuring the response of soil and plant water status to step change reductions in the water pressure within the tubes. Soybeans were germinated and grown in a porous ceramic 'soil' at a porous tube water pressure of -0.5 kpa for 28 d. During this time, the soil matric potential was nearly in equilibrium with tube water pressure. Water pressure in the porous tubes was then reduced to either -1.0, -1.5 or -2.0 kPa. Sap flow rates, leaf conductance and soil, root and leaf water potentials were measured before and after this change. A reduction in porous tube water pressure from -0.5 to -1.0 or -1.5 kPa did not result in any significant change in soil or plant water status. A reduction in porous tube water pressure to -2.0 kPa resulted in significant reductions in sap flow, leaf conductance, and soil, root and leaf water potentials. Hydraulic conductance, calculated as the transpiration rate/delta psi between two points in the water transport pathway, was used to analyse water transport through the tube-soil-plant continuum. At porous tube water pressures of -0.5 to-1.5 kPa soil moisture was readily available and hydraulic conductance of the plant limited water transport. At -2.0 kPa, hydraulic conductance of the bulk soil was the dominant factor in water movement.

  3. Response of the water status of soybean to changes in soil water potentials controlled by the water pressure in microporous tubes

    NASA Technical Reports Server (NTRS)

    Steinberg, S. L.; Henninger, D. L.

    1997-01-01

    Water transport through a microporous tube-soil-plant system was investigated by measuring the response of soil and plant water status to step change reductions in the water pressure within the tubes. Soybeans were germinated and grown in a porous ceramic 'soil' at a porous tube water pressure of -0.5 kpa for 28 d. During this time, the soil matric potential was nearly in equilibrium with tube water pressure. Water pressure in the porous tubes was then reduced to either -1.0, -1.5 or -2.0 kPa. Sap flow rates, leaf conductance and soil, root and leaf water potentials were measured before and after this change. A reduction in porous tube water pressure from -0.5 to -1.0 or -1.5 kPa did not result in any significant change in soil or plant water status. A reduction in porous tube water pressure to -2.0 kPa resulted in significant reductions in sap flow, leaf conductance, and soil, root and leaf water potentials. Hydraulic conductance, calculated as the transpiration rate/delta psi between two points in the water transport pathway, was used to analyse water transport through the tube-soil-plant continuum. At porous tube water pressures of -0.5 to-1.5 kPa soil moisture was readily available and hydraulic conductance of the plant limited water transport. At -2.0 kPa, hydraulic conductance of the bulk soil was the dominant factor in water movement.

  4. Eddy current technique for predicting burst pressure

    DOEpatents

    Petri, Mark C.; Kupperman, David S.; Morman, James A.; Reifman, Jaques; Wei, Thomas Y. C.

    2003-01-01

    A signal processing technique which correlates eddy current inspection data from a tube having a critical tubing defect with a range of predicted burst pressures for the tube is provided. The method can directly correlate the raw eddy current inspection data representing the critical tubing defect with the range of burst pressures using a regression technique, preferably an artificial neural network. Alternatively, the technique deconvolves the raw eddy current inspection data into a set of undistorted signals, each of which represents a separate defect of the tube. The undistorted defect signal which represents the critical tubing defect is related to a range of burst pressures utilizing a regression technique.

  5. [Characterizing the passive opening of the eustachian tube in a hypo-/hyperbaric pressure chamber].

    PubMed

    Meyer, M F; Mikolajczak, S; Luers, J C; Lotfipour, S; Beutner, D; Jumah, M D

    2013-09-01

    Beside arbitrary and not arbitrary active pressure equalization systems there is a passive equalization system via the Eustachian tube (ET) at pressure difference between the epipharyngeal space and the middle ear. Aim of this study was to characterize this passive equalization system in a hypobaric/hyperbaric pressure chamber by continuously measuring the tympanic impedance. In contrast to other studies, which are measured only in a hypobaric pressure chamber it is possible to include participants with Eustachian tube dysfunction (ETD). Following a fixed pressure profile 39 participants were exposed to phases of pressure rising and decompression. By continuously measuring the tympanic impedance in the pressure chamber it was possible to measure data of the Eustachian Tube opening Pressure (ETOP), Eustachian Tube closing pressure (ETCP) and Eustachian Tube opening duration (ETOD). In addition it was possible to characterize the gradient of pressure during decompression, while the ET was open. Beside the measurement of the arithmetic average of the ETOP (30.2 ± 15.1 mbar), ETCP (9.1 ± 7.7 mbar) and ETOD (0.65 ± 0.38 s) it was obvious that there are recurrent samples of pressure progression during the phase of tube opening. Generally it is possible to differentiate between the type of complete opening and partial opening. The fundamental characterization of the action of the passive tube opening, including the measurement of the ETOP, ETCP and ETOD, is a first step in understanding the physiological and pathophysiological function of the ET. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Dynamics of explosively imploded pressurized tubes

    NASA Astrophysics Data System (ADS)

    Szirti, Daniel; Loiseau, Jason; Higgins, Andrew; Tanguay, Vincent

    2011-04-01

    The detonation of an explosive layer surrounding a pressurized thin-walled tube causes the formation of a virtual piston that drives a precursor shock wave ahead of the detonation, generating very high temperatures and pressures in the gas contained within the tube. Such a device can be used as the driver for a high energy density shock tube or hypervelocity gas gun. The dynamics of the precursor shock wave were investigated for different tube sizes and initial fill pressures. Shock velocity and standoff distance were found to decrease with increasing fill pressure, mainly due to radial expansion of the tube. Adding a tamper can reduce this effect, but may increase jetting. A simple analytical model based on acoustic wave interactions was developed to calculate pump tube expansion and the resulting effect on the shock velocity and standoff distance. Results from this model agree quite well with experimental data.

  7. Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air and Saline Filled Cuffs

    DTIC Science & Technology

    2017-01-31

    AFRL-SA-WP-SR-2017-0004 Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled...Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled Cuffs 5a. CONTRACT NUMBER FA8650-14...descending from altitude. When using saline in the ETT cuff, TW pressure differences with the 7.5 high-volume, low-pressure cuff and 8.0 TaperGuard

  8. Method for shaping polyethylene tubing

    NASA Technical Reports Server (NTRS)

    Kramer, R. C.

    1981-01-01

    Method forms polyethylene plastic tubing into configurations previously only possible with metal tubing. By using polyethylene in place of copper or stain less steel tubing inlow pressure systems, fabrication costs are significantly reduced. Polyethylene tubing can be used whenever low pressure tubing is needed in oil operations, aircraft and space applications, powerplants, and testing laboratories.

  9. Implosion-driven technique to create fast shockwaves in high-density gas

    NASA Astrophysics Data System (ADS)

    Serge, Matthew; Loiseau, Jason; Huneault, Justin; Szirti, Daniel; Higgins, Andrew; Tanguay, Vincent

    2012-03-01

    Pressurized tubes surrounded by either one or two layers (separated by a secondary tube) of sensitized nitromethane and encased in a thick-walled tube (the tamper) were imploded. The distance between the detonation wave in the explosive and shock wave in the innermost tube were measured (the standoff). A simple model based on hoop stress and acoustic interactions between the tubing was developed and used to predict the standoff distance. At low initial pressures (on the order of 7MPa), results indicate that the secondary tube and two layers of explosive did not prove to significantly increase the standoff. However, at higher pressures (on the order of 10 MPa), standoff was noticeably greater when the secondary tube was inserted between the pressurized tube and the tamper. The measured values are in reasonable agreement with the predictions of the model.

  10. Variation of the pressure limits of flame propagation with tube diameter for propane-air mixtures

    NASA Technical Reports Server (NTRS)

    Belles, Frank E; Simon, Dorothy M

    1951-01-01

    An investigation was made of the variation of the pressure limits of flame propagation with tube diameter for quiescent propane with tube diameter for quiescent propane-air mixtures. Pressure limits were measured in glass tubes of six different inside diameters, with a precise apparatus. Critical diameters for flame propagation were calculated and the effect of pressure was determined. The critical diameters depended on the pressure to the -0.97 power for stoichiometric mixtures. The pressure dependence decreased with decreasing propane concentration. Critical diameters were related to quenching distance, flame speeds, and minimum ignition energy.

  11. Convertible socket for pressure gauge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bissell, R.D.

    1990-01-01

    This patent describes a pressure gauge having a case in which is disposed a Bourdon tube and a base socket connected to the Bourdon tube for placing the tube in pressure communication with a fluid pressure source. Base socket has a rearward face and a bottom face with respect to the gauge adjacent openings defined through the case and an internal passage communication with the tube. It includes means for connecting a source of fluid pressure to the socket selectively through one of the case openings to the bottom face or the rearward face.

  12. Dual-Latching, Solenoid-Actuated Tube Valve

    NASA Technical Reports Server (NTRS)

    Brudnicki, Myron J.

    1993-01-01

    Tube-type shutoff valve electrically positioned to open or closed state by concentric solenoid. Solenoid dual latching: it holds position until changed electrically or manually. In tube valve, central tube slides axially, closing off flow when held against seat and allowing flow when backed away from seat. Simple to balance pressure on seal between seat and sharp edge of tube. With pressure-balanced seal, only small force needed to hold valve in position, regardless of pressure acting on valve.

  13. An in vitro evaluation of the influence of neonatal endotracheal tube diameter and length on the work of breathing.

    PubMed

    Miyake, Fuyu; Suga, Rika; Akiyama, Takahiro; Namba, Fumihiko

    2018-04-06

    Neonates, particularly premature babies, are often managed with endotracheal intubation and subsequent mechanical ventilation to maintain adequate pulmonary gas exchange. There is no consensus on the standard length of endotracheal tube. Although a short tube reduces resistance and respiratory dead space, it is believed to increase the risk of accidental extubation. There are not entirely coherent data regarding the effect of endotracheal tube length on work of breathing in infants. The aim of this study was to evaluate the impact of neonatal endotracheal tube diameter and length on the work of breathing using an infant in vitro lung model. We assessed the work of breathing index and mechanical ventilation settings with various endotracheal tube diameters and lengths using the JTR100 in vitro infant lung model. The basic parameters of the model were breathing frequency of 20 per minutes, inspiratory-expiratory ratio of 1:3, and positive end-expiratory pressure of 5 cmH 2 O. In addition, the diaphragm driving pressure to maintain the set tidal volume was measured as the work of breathing index. The JTR100 was connected to the Babylog 8000plus through the endotracheal tube. Finally, we monitored the peak inspiratory pressure generated during assist-control volume guarantee mode with a targeted tidal volume of 10-30 mL. The diaphragm driving pressure using a 2.0-mm inner diameter tube was twice as high as that using a 4.0-mm inner diameter tube. To maintain the targeted tidal volume, a shorter tube reduced both the diaphragm driving pressure and ventilator-generated peak inspiratory pressure. The difference in the generated peak inspiratory pressure between the shortest and longest tubes was 5 cmH 2 O. In our infant lung model, a shorter tube resulted in a lower work of breathing and lower ventilator-generated peak inspiratory pressure. © 2018 John Wiley & Sons Ltd.

  14. Water cooled static pressure probe

    NASA Technical Reports Server (NTRS)

    Lagen, Nicholas T. (Inventor); Eves, John W. (Inventor); Reece, Garland D. (Inventor); Geissinger, Steve L. (Inventor)

    1991-01-01

    An improved static pressure probe containing a water cooling mechanism is disclosed. This probe has a hollow interior containing a central coolant tube and multiple individual pressure measurement tubes connected to holes placed on the exterior. Coolant from the central tube symmetrically immerses the interior of the probe, allowing it to sustain high temperature (in the region of 2500 F) supersonic jet flow indefinitely, while still recording accurate pressure data. The coolant exits the probe body by way of a reservoir attached to the aft of the probe. The pressure measurement tubes are joined to a single, larger manifold in the reservoir. This manifold is attached to a pressure transducer that records the average static pressure.

  15. Resonance Tube Phonation in Water-the Effect of Tube Diameter and Water Depth on Back Pressure and Bubble Characteristics at Different Airflows.

    PubMed

    Wistbacka, Greta; Andrade, Pedro Amarante; Simberg, Susanna; Hammarberg, Britta; Södersten, Maria; Švec, Jan G; Granqvist, Svante

    2018-01-01

    Resonance tube phonation with tube end in water is a voice therapy method in which the patient phonates through a glass tube, keeping the free end of the tube submerged in water, creating bubbles. The purpose of this experimental study was to determine flow-pressure relationship, flow thresholds between bubble types, and bubble frequency as a function of flow and back volume. A flow-driven vocal tract simulator was used for recording the back pressure produced by resonance tubes with inner diameters of 8 and 9 mm submerged at water depths of 0-7 cm. Visual inspection of bubble types through video recording was also performed. The static back pressure was largely determined by the water depth. The narrower tube provided a slightly higher back pressure for a given flow and depth. The amplitude of the pressure oscillations increased with flow and depth. Depending on flow, the bubbles were emitted from the tube in three distinct types with increasing flow: one by one, pairwise, and in a chaotic manner. The bubble frequency was slightly higher for the narrower tube. An increase in back volume led to a decrease in bubble frequency. This study provides data on the physical properties of resonance tube phonation with the tube end in water. This information will be useful in future research when looking into the possible effects of this type of voice training. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  16. Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ardhapurkar, P. M.; Sridharan, Arunkumar; Atrey, M. D.

    2014-01-29

    A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends onmore » the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models.« less

  17. Research on Annular Frictional Pressure Loss of Hydraulic-Fracturing in Buckling Coiled Tubing

    NASA Astrophysics Data System (ADS)

    Liu, Bin; Cai, Meng; Li, Junliang; Xu, Yongquan; Wang, Peng

    2018-01-01

    Compared with conventional hydraulic fracturing, coiled tubing (CT) annular delivery sand fracturing technology is a new method to enhance the recovery ratio of low permeability reservoir. Friction pressure loss through CT has been a concern in fracturing. The small diameter of CT limits the cross-sectional area open to flow, therefore, to meet large discharge capacity, annular delivery sand technology has been gradually developed in oilfield. Friction pressure is useful for determining the required pump horsepower and fracturing construction design programs. Coiled tubing can buckle when the axial compressive load acting on the tubing is greater than critical buckling load, then the geometry shape of annular will change. Annular friction pressure loss elevates dramatically with increasing of discharge capacity, especially eccentricity and CT buckling. Despite the frequency occurrence of CT buckling in oilfield operations, traditionally annular flow frictional pressure loss considered concentric and eccentric annuli, not discussing the effects of for discharge capacity and sand ratio varying degree of CT buckling. The measured data shows that the factors mentioned above cannot be ignored in the prediction of annular pressure loss. It is necessary to carry out analysis of annulus flow pressure drop loss in coiled tubing annular with the methods of theoretical analysis and numerical simulation. Coiled tubing buckling has great influence on pressure loss of fracturing fluid. Therefore, the correlations have been developed for turbulent flow of Newtonian fluids and Two-phase flow (sand-liquid), and that improve the friction pressure loss estimation in coiled tubing operations involving a considerable level of buckling. Quartz sand evidently increases pressure loss in buckling annular, rising as high as 40%-60% more than fresh water. Meanwhile, annulus flow wetted perimeter increases with decreasing helical buckling pitch of coiled tubing, therefore, the annulus flow frictional pressure loss rapidly increases with decreasing helical buckling pitch. The research achievement provides theoretical guidance for coiled tubing annular delivery sand fracturing operation and design.

  18. Pressurized security barrier and alarm system

    DOEpatents

    Carver, Don W.

    1995-01-01

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder's making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed.

  19. Pressurized security barrier and alarm system

    DOEpatents

    Carver, D.W.

    1995-04-11

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder`s making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed. 7 figures.

  20. Measurement of static pressure on aircraft

    NASA Technical Reports Server (NTRS)

    Gracey, William

    1958-01-01

    Existing data on the errors involved in the measurement of static pressure by means of static-pressure tubes and fuselage vents are presented. The errors associated with the various design features of static-pressure tubes are discussed for the condition of zero angle of attack and for the case where the tube is inclined to flow. Errors which result from variations in the configuration of static-pressure vents are also presented. Errors due to the position of a static-pressure tube in the flow field of the airplane are given for locations ahead of the fuselage nose, ahead of the wing tip, and ahead of the vertical tail fin. The errors of static-pressure vents on the fuselage of an airplane are also presented. Various methods of calibrating static-pressure installations in flight are briefly discussed.

  1. Effect of tubing condensate on non-invasive positive pressure ventilators tested under simulated clinical conditions.

    PubMed

    Hart, Diana Elizabeth; Forman, Mark; Veale, Andrew G

    2011-09-01

    Water condensate in the humidifier tubing can affect bi-level ventilation by narrowing tube diameter and increasing airflow resistance. We investigated room temperature and tubing type as ways to reduce condensate and its effect on bi-level triggering and pressure delivery. In this bench study, the aim was to test the hypothesis that a relationship exists between room temperature and tubing condensate. Using a patient simulator, a Res-med bi-level device was set to 18/8 cm H(2)O and run for 6 h at room temperatures of 16°C, 18°C and 20°C. The built-in humidifier was set to a low, medium or high setting while using unheated or insulated tubing or replaced with a humidifier using heated tubing. Humidifier output, condensate, mask pressure and triggering delay of the bi-level were measured at 1 and 6 h using an infrared hygrometer, metric weights, Honeywell pressure transducer and TSI pneumotach. When humidity output exceeded 17.5 mg H(2)O/L, inspiratory pressure fell by 2-15 cm H(2)O and triggering was delayed by 0.2-0.9 s. Heating the tubing avoided any such ventilatory effect whereas warmer room temperatures or insulating the tubing were of marginal benefit. Users of bi-level ventilators need to be aware of this problem and its solution. Bi-level humidifier tubing may need to be heated to ensure correct humidification, pressure delivery and triggering.

  2. High accuracy differential pressure measurements using fluid-filled catheters - A feasibility study in compliant tubes.

    PubMed

    Rotman, Oren Moshe; Weiss, Dar; Zaretsky, Uri; Shitzer, Avraham; Einav, Shmuel

    2015-09-18

    High accuracy differential pressure measurements are required in various biomedical and medical applications, such as in fluid-dynamic test systems, or in the cath-lab. Differential pressure measurements using fluid-filled catheters are relatively inexpensive, yet may be subjected to common mode pressure errors (CMP), which can significantly reduce the measurement accuracy. Recently, a novel correction method for high accuracy differential pressure measurements was presented, and was shown to effectively remove CMP distortions from measurements acquired in rigid tubes. The purpose of the present study was to test the feasibility of this correction method inside compliant tubes, which effectively simulate arteries. Two tubes with varying compliance were tested under dynamic flow and pressure conditions to cover the physiological range of radial distensibility in coronary arteries. A third, compliant model, with a 70% stenosis severity was additionally tested. Differential pressure measurements were acquired over a 3 cm tube length using a fluid-filled double-lumen catheter, and were corrected using the proposed CMP correction method. Validation of the corrected differential pressure signals was performed by comparison to differential pressure recordings taken via a direct connection to the compliant tubes, and by comparison to predicted differential pressure readings of matching fluid-structure interaction (FSI) computational simulations. The results show excellent agreement between the experimentally acquired and computationally determined differential pressure signals. This validates the application of the CMP correction method in compliant tubes of the physiological range for up to intermediate size stenosis severity of 70%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Flight evaluation of a pneumatic system for unsteady pressure measurements using conventional sensors

    NASA Technical Reports Server (NTRS)

    Curry, Robert E.; Gilyard, Glenn B.

    1989-01-01

    A flight experiment was conducted to evaluate a pressure measurement system which uses pneumatic tubing and remotely located electronically scanned pressure transducer modules for in-flight unsteady aerodynamic studies. A parametric study of tubing length and diameter on the attenuation and lag of the measured signals was conducted. The hardware was found to operate satisfactorily at rates of up to 500 samples/sec per port in flight. The signal attenuation and lag due to tubing were shown to increase with tubing length, decrease with tubing diameter, and increase with altitude over the ranges tested. Measurable signal levels were obtained for even the longest tubing length tested, 4 ft, at frequencies up to 100 Hz. This instrumentation system approach provides a practical means of conducting detailed unsteady pressure surveys in flight.

  4. Dynamic calibration of fast-response probes in low-pressure shock tubes

    NASA Astrophysics Data System (ADS)

    Persico, G.; Gaetani, P.; Guardone, A.

    2005-09-01

    Shock tube flows resulting from the incomplete burst of the diaphragm are investigated in connection with the dynamic calibration of fast-response pressure probes. As a result of the partial opening of the diaphragm, pressure disturbances are observed past the shock wave and the measured total pressure profile deviates from the envisaged step signal required by the calibration process. Pressure oscillations are generated as the initially normal shock wave diffracts from the diaphragm's orifice and reflects on the shock tube walls, with the lowest local frequency roughly equal to the ratio of the sound speed in the perturbed region to the shock tube diameter. The energy integral of the perturbations decreases with increasing distance from the diaphragm, as the diffracted leading shock and downwind reflections coalesce into a single normal shock. A procedure is proposed to calibrate fast-response pressure probes downwind of a partially opened shock tube diaphragm.

  5. Nonlinear Stability and Saturation of Ballooning Modes in Tokamaks*

    NASA Astrophysics Data System (ADS)

    Ham, C. J.; Cowley, S. C.; Brochard, G.; Wilson, H. R.

    2016-06-01

    The theory of tokamak stability to nonlinear "ballooning" displacements of elliptical magnetic flux tubes is presented. Above a critical pressure profile the energy stored in the plasma may be lowered by finite (but not infinitesimal) displacements of such tubes (metastability). Above a higher pressure profile, the linear stability boundary, such tubes are linearly and nonlinearly unstable. The predicted saturated flux tube displacement can be of the order of the pressure gradient scale length. Plasma transport from these displaced flux tubes may explain the rapid loss of confinement in some experiments.

  6. Investigation of the effect of a bend in a transfer line that separates a pulse tube cold head and a pressure wave generator

    NASA Astrophysics Data System (ADS)

    Dev, A. A.; Atrey, M. D.; Vanapalli, S.

    2017-02-01

    A transfer line between a pulse tube cold head and a pressure wave generator is usually required to isolate the cold head from the vibrations of the compressor. Although it is a common practice to use a thin and narrow straight tube, a bent tube would allow design flexibility and easy mounting of the cold head, such as in a split Stirling type pulse tube cryocooler. In this paper, we report a preliminary investigation on the effect of the bending of the tube on the flow transfer characteristics. A numerical study using commercial computational fluid dynamics model is performed to gain insight into the flow characteristics in the bent tube. Oscillating flow experiments are performed with a straight and a bent tube at a filling pressure of 15 bar and an operating frequency of 40, 50 and 60 Hz. The data and the corresponding numerical simulations point to the hypothesis that the secondary flow in the bent tube causes a decrease in flow at a fixed pressure amplitude.

  7. Dynamic pressure sensitivity determination with Mach number method

    NASA Astrophysics Data System (ADS)

    Sarraf, Christophe; Damion, Jean-Pierre

    2018-05-01

    Measurements of pressure in fast transient conditions are often performed even if the dynamic characteristic of the transducer are not traceable to international standards. Moreover, the question of a primary standard in dynamic pressure is still open, especially for gaseous applications. The question is to improve dynamic standards in order to respond to expressed industrial needs. In this paper, the method proposed in the EMRP IND09 ‘Dynamic’ project, which can be called the ‘ideal shock tube method’, is compared with the ‘collective standard method’ currently used in the Laboratoire de Métrologie Dynamique (LNE/ENSAM). The input is a step of pressure generated by a shock tube. The transducer is a piezoelectric pressure sensor. With the ‘ideal shock tube method’ the sensitivity of a pressure sensor is first determined dynamically. This method requires a shock tube implemented with piezoelectric shock wave detectors. The measurement of the Mach number in the tube allows an evaluation of the incident pressure amplitude of a step using a theoretical 1D model of the shock tube. Heat transfer, other actual effects and effects of the shock tube imperfections are not taken into account. The amplitude of the pressure step is then used to determine the sensitivity in dynamic conditions. The second method uses a frequency bandwidth comparison to determine pressure at frequencies from quasi-static conditions, traceable to static pressure standards, to higher frequencies (up to 10 kHz). The measurand is also a step of pressure generated by a supposed ideal shock tube or a fast-opening device. The results are provided as a transfer function with an uncertainty budget assigned to a frequency range, also deliverable frequency by frequency. The largest uncertainty in the bandwidth of comparison is used to trace the final pressure step level measured in dynamic conditions, owing that this pressure is not measurable in a steady state on a shock tube. A reference sensor thereby calibrated can be used in a comparison measurement process. At high frequencies the most important component of the uncertainty in this method is due to actual shock tube complex effects not already functionalized nowadays or thought not to be functionalized in this kind of direct method. After a brief review of both methods and a brief review of the determination of the transfer function of pressure transducers, and the budget of associated uncertainty for the dynamic calibration of a pressure transducer in gas, this paper presents a comparison of the results obtained with the ‘ideal shock tube’ and the ‘collective standard’ methods.

  8. System for venting gas from a liquid storage tank

    NASA Astrophysics Data System (ADS)

    Dugan, Regina E.

    1989-07-01

    Gas is vented from a non-cryogenic liquid storage tank while discharging pressurized liquid from a tube into the tank through a plurality of inclined jets, circumferentially spaced about an end of a vent tube positioned within the tube. Each jet is directed toward a central axis of the vent tube, such that the end of the vent tube receives gas from the vessel passing between individual jetstreams, which in combination form a conical shaped barrier to liquid droplets which would otherwise also pass to the vent tube and out the tank. Gas is thus vented through the central tube while pressurized liquid flows in an axially opposite direction in the annulus between the inner vent tube and the outer liquid tube. The system of the present invention is prarticularly well suited for venting gas from a tank being replenished with liquid at a zero or near zero gravity environment. A screen-type liquid acquisition device employing surface tension is provided for withdrawing substantially liquid from the tank. The withdrawn liquid may be resupplied to the liquid tube under pressure supplied by a circulating pump, thereby releasing substantially only gas from the storage tank to reduce the pressure in the tank.

  9. Condensation heat transfer and pressure drop of R-410A in a 7.0 mm O.D. microfin tube at low mass fluxes

    NASA Astrophysics Data System (ADS)

    Kim, Nae-Hyun

    2016-12-01

    R-410A condensation heat transfer and pressure drop data are provided for a 7.0 mm O.D. microfin tube at low mass fluxes (50-250 kg/m2 s). The heat transfer coefficient of the microfin tube shows a minimum behavior with the mass flux. At a low mass flux, where flow pattern is stratified, condensation induced by surface tension by microfins overwhelms condensation induced by shear, and the heat transfer coefficient decreases as mass flux increases. At a high mass flux, where flow pattern is annular, condensation induced by shear governs the heat transfer, and the heat transfer coefficient increases as mass flux increases. The pressure drop of the microfin tube is larger than that of the smooth tube at the annular flow regime. On the contrary, the pressure drop of the smooth tube is larger than that of the microfin tube at the stratified flow regime.

  10. Reactor

    DOEpatents

    Evans, Robert M.

    1976-10-05

    1. A neutronic reactor having a moderator, coolant tubes traversing the moderator from an inlet end to an outlet end, bodies of material fissionable by neutrons of thermal energy disposed within the coolant tubes, and means for circulating water through said coolant tubes characterized by the improved construction wherein the coolant tubes are constructed of aluminum having an outer diameter of 1.729 inches and a wall thickness of 0.059 inch, and the means for circulating a liquid coolant through the tubes includes a source of water at a pressure of approximately 350 pounds per square inch connected to the inlet end of the tubes, and said construction including a pressure reducing orifice disposed at the inlet ends of the tubes reducing the pressure of the water by approximately 150 pounds per square inch.

  11. The influence of pressure ratio on the regenerator performance

    NASA Astrophysics Data System (ADS)

    Lin, Y.; Zhu, S.

    2017-12-01

    For a multi-stage pulse tube refrigerator with displacer, improving the regenerator efficiency is important. A displacer can get higher operating pressure ratio compared with inertance tube. The pressure ratio and porosity influence on the regenerator performance with is discussed, and CFD simulation is done on a two-stage pulse tube refrigerator with displacer to show that mass flow rate and pressure wave relation in the regenerator can be realized by a step-displacer.

  12. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    PubMed

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P < .001) from the preset level. Fluid aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P < .001) and was much more during 15 and 20 seconds suction time as compared to 5 seconds (P < .001). Massive aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  13. Explosion interaction with water in a tube

    NASA Astrophysics Data System (ADS)

    Homae, T.; Sugiyama, Y.; Wakabayashi, K.; Matsumura, T.; Nakayama, Y.

    2017-02-01

    As proposed and legislated in Japan, subsurface magazines have an explosive storage chamber, a horizontal passageway, and a vertical shaft for a vent. The authors found that a small amount of water on the floor of the storage chamber mitigated blast pressure remarkably. The mitigation mechanism has been examined more closely. To examine the effect of water, the present study assesses explosions in a transparent, square cross section, and a straight tube. A high-speed camera used to observe the tube interior. Blast pressure in and around the tube was also measured. Images obtained using the high-speed camera revealed that water inside the tube did not move after the explosion. Differences between cases of tubes without water and with water were unclear. Along with blast pressure measurements, these study results suggest that blast pressure mitigation by water occurs because of interaction between the explosion and the water near the explosion point.

  14. Study of Performance of Coaxial Vacuum Tube Solar Collector on Ethanol Distillation Process

    NASA Astrophysics Data System (ADS)

    Sutomo; Ramelan, A. H.; Mustafa; Tristono, T.

    2017-07-01

    Coaxial vacuum tube solar collectors can generate heat up to 80°C is possibly used for ethanol distillation process that required temperature 79°C only. This study reviews the performance of coaxial collector vacuum tube used for ethanol distillation process. This experimental research was conducted in a closed space using a halogen lamp as a solar radiation simulator. We had done on three different of the radiation values, i.e. 998 W/m2, 878 W/m2 and 782 W/m2. The pressure levels of vacuum tube collector cavity in the research were 1; 0.5; 0.31; 0.179; and 0.043 atmospheres. The Research upgraded the 30% of ethanol to produce the concentration of 77% after distillation. The result shows that the performance of coaxial collector vacuum tube used for ethanol distillation process has the negative correlation to the level of the collector tube cavity pressure. The productivity will increase while the collector tube cavity pressure decreased. Therefore, the collector efficiency has the negative correlation also to the level of collector tube cavity pressure. The best performance achieved when it operated at a pressure of 0.043 atmosphere with radiation intensity 878 W / m2, and the value of efficiency is 57.8%.

  15. Vertical laryngeal position and oral pressure variations during resonance tube phonation in water and in air. A pilot study.

    PubMed

    Wistbacka, Greta; Sundberg, Johan; Simberg, Susanna

    2016-10-01

    Resonance tube phonation in water (RTPW) is commonly used in voice therapy, particularly in Finland and Sweden. The method is believed to induce a lowering of the vertical laryngeal position (VLP) in phonation as well as variations of the oral pressure, possibly inducing a massage effect. This pilot study presents an attempt to measure VLP and oral pressure in two subjects during RTPW and during phonation with the free tube end in air. VLP is recorded by means of a dual-channel electroglottograph. RTPW was found to lower VLP in the subjects, while it increased during phonation with the tube end in air. RTPW caused an oral pressure modulation with a bubble frequency of 14-22 Hz, depending mainly on the depth of the tube end under the water surface. The results indicate that RTPW lowers the VLP instantly and creates oral pressure variations.

  16. Cuffed endotracheal tubes in children: the effect of the size of the cuffed endotracheal tube on intracuff pressure.

    PubMed

    Krishna, Senthil G; Hakim, Mumin; Sebastian, Roby; Dellinger, Heather L; Tumin, Dmitry; Tobias, Joseph D

    2017-05-01

    In children, the size of the cuffed endotracheal tube is based on various age-based formulas. However, such formulas may over or underestimate the size of the cuffed endotracheal tube. There are no data on the impact of different-sized cuffed endotracheal tubes (ETT) on the intracuff pressure in children. The current study measures intracuff pressure with different-sized cuffed ETT. The study was conducted in an in vitro and in vivo phase. For the in vitro phase, 10 cuffed ETT of size 4.0, 4.5, and 5 mm internal diameter (ID) each were randomly placed inside a 1.0 cm ID plastic tube (mimicking the trachea), which was in turn connected to a 1 l test lung. After inflation of the cuff using the air leak test at a continuous positive airway pressure of 20 cmH 2 O, the intracuff pressure was measured. The in vivo phase was conducted in 100 children (4-8 years) and were randomly divided into two groups to receive either a cuffed endotracheal tube based on the Khine formula (Group R) or a cuffed endotracheal tube that was a half-size (0.5 mm ID) smaller (Group S). Following the inflation of the cuff to seal the trachea, the intracuff pressure was measured. In the in vitro phase, the intracuff pressure was 45 ± 6, 23 ± 1, and 14 ± 6 cmH 2 O with size 4.0, 4.5, and 5 mm ID cuffed ETT, respectively (F-test P < 0.001 for difference among three groups). In the in vivo phase, the mean intracuff pressure in Group R was 25 ± 19 cmH 2 O vs 37 ± 35 cmH 2 O in Group S (95% CI of difference: 1, 23; P = 0.039). If the cuffed endotracheal tube is too small, the trachea can still be sealed by inflating the cuff with additional air. However, this transforms the cuff from the intended high-volume, low-pressure cuff to an undesirable high-volume, high-pressure cuff. © 2017 John Wiley & Sons Ltd.

  17. Elevation correction factor for absolute pressure measurements

    NASA Technical Reports Server (NTRS)

    Panek, Joseph W.; Sorrells, Mark R.

    1996-01-01

    With the arrival of highly accurate multi-port pressure measurement systems, conditions that previously did not affect overall system accuracy must now be scrutinized closely. Errors caused by elevation differences between pressure sensing elements and model pressure taps can be quantified and corrected. With multi-port pressure measurement systems, the sensing elements are connected to pressure taps that may be many feet away. The measurement system may be at a different elevation than the pressure taps due to laboratory space or test article constraints. This difference produces a pressure gradient that is inversely proportional to height within the interface tube. The pressure at the bottom of the tube will be higher than the pressure at the top due to the weight of the tube's column of air. Tubes with higher pressures will exhibit larger absolute errors due to the higher air density. The above effect is well documented but has generally been taken into account with large elevations only. With error analysis techniques, the loss in accuracy from elevation can be easily quantified. Correction factors can be applied to maintain the high accuracies of new pressure measurement systems.

  18. The Measurement of Pressure Through Tubes in Pressure Distribution Tests

    NASA Technical Reports Server (NTRS)

    Hemke, Paul E

    1928-01-01

    The tests described in this report were made to determine the error caused by using small tubes to connect orifices on the surface of aircraft to central pressure capsules in making pressure distribution tests. Aluminum tubes of 3/16-inch inside diameter were used to determine this error. Lengths from 20 feet to 226 feet and pressures whose maxima varied from 2 inches to 140 inches of water were used. Single-pressure impulses for which the time of rise of pressure from zero to a maximum varied from 0.25 second to 3 seconds were investigated. The results show that the pressure recorded at the capsule on the far end of the tube lags behind the pressure at the orifice end and experiences also a change in magnitude. For the values used in these tests the time lag and pressure change vary principally with the time of rise of pressure from zero to a maximum and the tube length. Curves are constructed showing the time lag and pressure change. Empirical formulas are also given for computing the time lag. Analysis of pressure distribution tests made on airplanes in flight shows that the recorded pressures are slightly higher than the pressures at the orifice and that the time lag is negligible. The apparent increase in pressure is usually within the experimental error, but in the case of the modern pursuit type of airplane the pressure increase may be 5 per cent. For pressure-distribution tests on airships the analysis shows that the time lag and pressure change may be neglected.

  19. Pressure drop in tubing in aircraft instrument installations

    NASA Technical Reports Server (NTRS)

    Wildhack, W A

    1937-01-01

    The theoretical basis of calculation of pressure drop in tubing is reviewed briefly. The effect of pressure drop in connecting tubing upon the operation and indication of aircraft instruments is discussed. Approximate equations are developed, and charts and tables based upon them are presented for use in designing installations of altimeters, air-speed indicators, rate-of-climb indicators, and air-driven gyroscopic instruments.

  20. Workshop proceedings: U-bend tube cracking in steam generators

    NASA Astrophysics Data System (ADS)

    Shoemaker, C. E.

    1981-06-01

    A design to reduce the rate of tube failure in high pressure feedwater heaters, a number of failed drawn and stress relieved Monel 400 U-bend tubes removed from three high pressure feedwater heaters was examined. Steam extracted from the turbine is used to preheat the boiler feedwater in fossil fuel fired steam plants to improve thermal efficiency. This is accomplished in a series of heaters between the condenser hot well and the boiler. The heaters closest to the boiler handle water at high pressure and temperature. Because of the severe service conditions, high pressure feedwater heaters are frequently tubed with drawn and stress relieved Monel 400.

  1. 75 FR 16655 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 700 Series Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... pressure (HP-IP) turbine internal and external oil vent tubes for coking and carbon buildup, and cleaning... borescope inspections of the HP-IP turbine internal and external oil vent tubes for coking and carbon...-intermediate pressure (HP-IP) turbine internal oil vent tubes, external oil vent tubes, and bearing chamber...

  2. Confined Tube Crimp Using Portable Hand Tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, Joseph James; Pereyra, R. A.; Archuleta, Jeffrey Christopher

    2016-04-04

    The Lawrence Radiation Laboratory developed handheld tools that crimp a 1/16 inch OD tube, forming a leak tight seal1 (see Figure 1). The leak tight seal forms by confining the 1/16 inch OD tubing inside a die while applying crimp pressure. Under confined pressure, the tube walls weld at the crimp. The purpose of this study was to determine conditions for fabricating a leak tight tube weld. The equipment was used on a trial-and-error basis, changing the conditions after each attempt until successful welds were fabricated. To better confine the tube, the die faces were polished. Polishing removed a fewmore » thousandths of an inch from the die face, resulting in a tighter grip on the tubing wall. Using detergent in an ultrasonic bath, the tubing was cleaned. Also, the time under crimp pressure was increased to 30 seconds. With these modifications, acceptable cold welds were fabricated. After setting the conditions for an acceptable cold weld, the tube was TIG welded across the crimped face.« less

  3. An Experimental Investigation of Fluid Flow and Heating in Various Resonance Tube Modes

    NASA Technical Reports Server (NTRS)

    Sarohia, V.; Back, L. H.; Roschke, E. J.; Pathasarathy, S. P.

    1976-01-01

    Experiments have been performed to study resonance phenomena in tubes excited by underexpanded jet flows. This investigation comprised the following: Study of the various resonance tube modes under a wide range of nozzle pressure, spacing between nozzle and tube mouth, and different tube length; the effects of these modes on the endwall pressure and gas temperature; flow visualization of both jet and tube flows by spark shadowgraph technique; and measurement of wave speed inside the tube by the laser-schlieren techniques. An extensive study of the free-jet flow was undertaken to explain important aspects of various modes of operation of resonance tube flows.

  4. A novel investigation of heat transfer characteristics in rifled tubes

    NASA Astrophysics Data System (ADS)

    Jegan, C. Dhayananth; Azhagesan, N.

    2018-05-01

    The experimental investigation of heat transfer of water flowing in a rifled tube was explored at different pressures and at various operating conditions in a rifled tube heat exchanger. The specifications for the inner and outer diameters of the inner tube are 25.8 and 50.6 mm, respectively. The working fluids used in shell side and tube side are cold and hot water. The rifled tube was made of the stainless steel with 4 ribs, 50.6 mm outer diameter, 0.775 mm rib height, 58o helix angle and the length 1500 mm. The effect of pressure, wall heat flux and friction factor were discussed. The results confirm that even at low pressures the rifled tubes has an obvious enhancement in heat transfer compared with smooth tube. Results depicts that the Nusselt number increases with Reynolds number and the friction factor decreases with increase in Reynolds number and the heat transfer rate is higher for the rifled tube when compared to smooth tube, because of strong swirl flow due to centrifugal action. It also confirms that, the friction factor obtained from the rifled tube is significantly higher than that of smooth tube.

  5. "Zero-Mass" Noninvasive Pressure Transducers

    NASA Technical Reports Server (NTRS)

    Hartley, Frank T.

    2009-01-01

    Extremely lightweight, compact, noninvasive, rugged, relatively inexpensive strain-gauge transducers have been developed for use in measuring pressures of fluids in tubes. These gauges were originally intended for measuring pressures of spacecraft-propulsion fluids, but they are also attractive for use in numerous terrestrial applications especially those involving fluids that are extremely chemically reactive, fluids that must be isolated for hygienic purposes, fluids that must be allowed to flow without obstruction, and fluid-containing tubes exposed to severe environments. A basic pressure transducer of this type comprises one or more pair(s) of thin-film strain gauges integral with a tube that contains the fluid of interest. Following established strain-gauge practice, the gauges in each pair are connected into opposite arms of a Wheatstone bridge (see figure). Typically, each pressure transducer includes one pair (the active pair) of strain gauges for measuring the hoop stress proportional to the pressure of the fluid in the tube and another pair (the dummy pair) of strain gauges that are nominally unstrained: The dummy gauges are mounted on a substrate that is made of the same material as that of the tube. The substrate is welded to the tube at only one spot so that stresses and strains are not coupled from the tube into the substrate. The dummy strain gauges measure neutral strains (basically, strains associated with thermal expansion), so that the neutral-strain contribution can be subtracted out of the final gauge reading.

  6. Adjustable-Pressure Mandrel For Making Composite Tubes

    NASA Technical Reports Server (NTRS)

    Jacoy, Paul J.; Schmitigal, Wesley P.

    1993-01-01

    Inflatable inner mandrel enables application of any desired pressure (within reasonable limits) during curing stage in fabrication of fiber/matrix composite tube. Consists mainly of sheath of silicone rubber sealed on aluminum tube. Composite material laid up on mandrel and enclosed in rigid outer die. Sheath on inner mandrel inflated to requisite pressure and regulated during curing. Assembly then placed in oven and cured at specified temperature.

  7. Study on the technology of dual-tube layered injection in ASP flooding

    NASA Astrophysics Data System (ADS)

    Yang, Ye; Zhang, Yongping; Xu, Dekui; Cai, Meng; Yang, Zhigang; Wang, Hailong; Song, Xingliang

    2017-10-01

    For the single-tube layered injection technology cannot solve the problem of interlayer pressure difference is greater than 2MPa injection wells, through the development of dual-tube packer, dual-tube injection allocator, downhole plug, the ground pressure regulator and molecular weight regulator. Dual-tube layered injection technology is formed. According to the data of ASP flooding injection wells in the field, the whole well is divided into high permeability and low permeability oil reservoir. Two separate injection channels can be formed by using dual-tube packer and dual-tube injection allocator. Through the use of the ground pressure regulator, the problem of the high permeability layer and low permeability layer of the injection pressure difference is solved. Through the use of the ground molecular weight regulator, the problem that the same molecular weight ASP solution is not suitable for high and low permeability is solved. By replacing the downhole plug, the grouping transformation of some oil layer can be achieved. The experiment and field application of 3 wells results show that: the flow control range is 20m3/d-70m3/d; the max. Throttling differential pressure is 3.5MPa; the viscosity loss rate of solution is less than 5%; and the molecular weight adjusting range is 20%-50%. The utilization degree of oil layer is obviously increased through the use of the dual-tube layered injection technology.

  8. Numerical simulation of tubes-in-tube heat exchanger in a mixed refrigerant Joule-Thomson cryocooler

    NASA Astrophysics Data System (ADS)

    Damle, R. M.; Ardhapurkar, P. M.; Atrey, M. D.

    2017-02-01

    Mixed refrigerant Joule-Thomson (MRJT) cryocoolers can produce cryogenic temperatures with high efficiency and low operating pressures. As compared to the high system pressures of around 150-200 bar with nitrogen, the operational pressures with non-azeotropic mixtures (e.g., nitrogen-hydrocarbons) come down to 10-25 bar. With mixtures, the heat transfer in the recuperative heat exchanger takes place in the two-phase region. The simultaneous boiling and condensation of the cold and hot gas streams lead to higher heat transfer coefficients as compared to single phase heat exchange. The two-phase heat transfer in the recuperative heat exchanger drastically affects the performance of a MRJT cryocooler. In this work, a previously reported numerical model for a simple tube-in-tube heat exchanger is extended to a multi tubes-in-tube heat exchanger with a transient formulation. Additionally, the J-T expansion process is also considered to simulate the cooling process of the heat exchanger from ambient temperature conditions. A tubes-in-tube heat exchanger offers more heat transfer area per unit volume resulting in a compact design. Also, the division of flow in multiple tubes reduces the pressure drop in the heat exchanger. Simulations with different mixtures of nitrogen-hydrocarbons are carried out and the numerical results are compared with the experimental data.

  9. Controlled differential pressure system for an enhanced fluid blending apparatus

    DOEpatents

    Hallman, Jr., Russell Louis

    2009-02-24

    A system and method for producing a controlled blend of two or more fluids. Thermally-induced permeation through a permeable tube is used to mix a first fluid from outside the tube with a second fluid flowing through the tube. Mixture ratios may be controlled by adjusting the temperature of the first fluid or by adjusting the pressure drop through the permeable tube. The combination of a back pressure control valve and a differential regulator is used to control the output pressure of the blended fluid. The combination of the back pressure control valve and differential regulator provides superior flow control of the second dry gas. A valve manifold system may be used to mix multiple fluids, and to adjust the volume of blended fluid produced, and to further modify the mixture ratio.

  10. Ceramic heat exchanger

    DOEpatents

    LaHaye, Paul G.; Rahman, Faress H.; Lebeau, Thomas P. E.; Severin, Barbara K.

    1998-01-01

    A tube containment system. The tube containment system does not significantly reduce heat transfer through the tube wall. The contained tube is internally pressurized, and is formed from a ceramic material having high strength, high thermal conductivity, and good thermal shock resistance. The tube containment system includes at least one ceramic fiber braid material disposed about the internally pressurized tube. The material is disposed about the tube in a predetermined axial spacing arrangement. The ceramic fiber braid is present in an amount sufficient to contain the tube if the tube becomes fractured. The tube containment system can also include a plurality of ceramic ring-shaped structures, in contact with the outer surface of the tube, and positioned between the tube and the ceramic fiber braid material, and/or at least one transducer positioned within tube for reducing the internal volume and, therefore, the energy of any shrapnel resulting from a tube fracture.

  11. Ceramic heat exchanger

    DOEpatents

    LaHaye, P.G.; Rahman, F.H.; Lebeau, T.P.; Severin, B.K.

    1998-06-16

    A tube containment system is disclosed. The tube containment system does not significantly reduce heat transfer through the tube wall. The contained tube is internally pressurized, and is formed from a ceramic material having high strength, high thermal conductivity, and good thermal shock resistance. The tube containment system includes at least one ceramic fiber braid material disposed about the internally pressurized tube. The material is disposed about the tube in a predetermined axial spacing arrangement. The ceramic fiber braid is present in an amount sufficient to contain the tube if the tube becomes fractured. The tube containment system can also include a plurality of ceramic ring-shaped structures, in contact with the outer surface of the tube, and positioned between the tube and the ceramic fiber braid material, and/or at least one transducer positioned within tube for reducing the internal volume and, therefore, the energy of any shrapnel resulting from a tube fracture. 6 figs.

  12. Residual Negative Pressure in Vacuum Tubes Might Increase the Risk of Spurious Hemolysis.

    PubMed

    Xiao, Tong-Tong; Zhang, Qiao-Xin; Hu, Jing; Ouyang, Hui-Zhen; Cai, Ying-Mu

    2017-05-01

    We planned a study to establish whether spurious hemolysis may occur when negative pressure remains in vacuum tubes. Four tubes with different vacuum levels (-54, -65, -74, and -86 kPa) were used to examine blood drawn from one healthy volunteer; the tubes were allowed to stand for different times (1, 2, 3, and 4 hours). The plasma was separated and immediately tested for free hemoglobin (FHb). Thirty patients were enrolled in a verification experiment. The degree of hemolysis observed was greater when the remaining negative pressure was higher. Significant differences were recorded in the verification experiment. The results suggest that residual negative pressure might increase the risk of spurious hemolysis.

  13. Temperature compensated liquid level sensor using FBGs and a Bourdon tube

    NASA Astrophysics Data System (ADS)

    Sengupta, D.; Shankar, M. Sai; Rao, P. Vengal; Reddy, P. Saidi; Sai Prasad, R. L. N.; Kishore, P.; Srimannarayana, K.

    2011-12-01

    A temperature compensated liquid level sensor using FBGs and a bourdon tube that works on hydrostatic pressure is presented. An FBG (FBG1) is fixed between free end and a fixed end of the bourdon tube. When hydrostatic pressure applied to the bourdon tube FBG1 experience an axial strain due to the movement of free end. Experimental result shows, a good linearity in shift in Bragg wavelength with the applied pressure. The performance of this arrangement is tested for 21metre water column pressure. Another FBG (FBG2) is included for temperature compensation. The design of the sensor head is simple and easy mountable external to any tank for liquid level measurements.

  14. Water Drinking Test: Intraocular Pressure Changes after Tube Surgery and Trabeculectomy.

    PubMed

    Razeghinejad, Mohammad Reza; Tajbakhsh, Zahra; Nowroozzadeh, Mohammad Hossein; Masoumpour, Masoumeh

    2017-01-01

    To study the effects of filtration surgeries (tube and trabeculectomy) on changes in intraocular pressure after a water-drinking test. In this prospective, non-randomized, comparative clinical study, 30 patients who had tube surgery and 30 age- and sex-matched trabeculectomy patients underwent a water-drinking test. Only one eye of each patient was included. The baseline intraocular pressure was ≤21 mmHg in all enrolled eyes with or without adjunctive topical medications. After the water-drinking test, the intraocular pressure was measured and recorded at 15, 30, 45, and 60 minutes and the results were compared between the two groups. In both groups, intraocular pressure significantly increased from baseline at all measured time-points ( P < 0.001). In the trabeculectomy group, the average intraocular pressure increased from 14.8 ± 2.9 to 18.8 ± 4.7 mmHg at 30 minutes, but decreased at 60 min (18.0 ± 5.2 mmHg). In the Tube group, intraocular pressure increased incrementally until the last measurement (14.2 ± 3.9, 18.8 ± 5.6, and 19.7 ± 6.0 mmHg at baseline, 30, and 60 minutes, respectively). The end-pressure difference (intraocular pressure at 60 minutes vs. baseline) was significantly greater in the tube group (5.6 ± 3.6 mmHg; 41% change) than in the trabeculectomy group (3.2 ± 4.7; 23% change; P = 0.03). Intraocular pressure significantly increased after the water-drinking test in both the groups. Intraocular pressure started to decline 30 minutes after the water-drinking test in the trabeculectomy group, while it continued to increase up to 60 minutes in the Tube group. This finding may have implications regarding the efficacy or safety of the procedures in advanced glaucoma patients.

  15. Bubble snap-off and capillary-back pressure during counter-current spontaneous imbibition into model pores.

    PubMed

    Unsal, Evren; Mason, Geoffrey; Morrow, Norman R; Ruth, Douglas W

    2009-04-09

    A previous paper (Unsal, E.; Mason, G.; Ruth, D. W.; Morrow, N. R. J. Colloid Interface Sci. 2007, 315, 200-209) reported experiments involving counter-current spontaneous imbibition into a model pore system consisting of a rod in an angled slot covered by a glass plate. Such an arrangement gives two tubes with different cross-sections (both size and shape) with an interconnection through the gap between the rod and the plate. In the previous experiments, the wetting phase advanced in the small tube and nonwetting phase retreated in the large tube. No bubbles were formed. In this paper, we study experimentally and theoretically the formation of bubbles at the open end of the large tube and their subsequent snap-off. Such bubbles reduce the capillary back pressure produced by the larger tube and can thus have an effect on the local rate of imbibition. In the model pore system, the rod was either in contact with the glass, forming two independent tubes, or the rod was spaced from the glass to allow cross-flow between the tubes. For small gaps, there were three distinct menisci. The one with the highest curvature was between the rod and the plate. The next most highly curved was in the smaller tube, and the least highly curved meniscus was in the large tube and this was the tube from which the bubbles developed. The pressure in the dead end of the system was recorded during imbibition. Once the bubble starts to form outside of the tube, the pressure drops rapidly and then steadies. After the bubble snaps off, the pressure rises to almost the initial value and stays essentially constant until the next bubble starts to form. After snap-off, the meniscus in the large tube appears to invade the large tube for some distance. The snap-off is the result of capillary instability; it takes place significantly inside the large tube with flow of wetting phase moving in the angular corners. As imbibition into the small tube progresses, the rate of imbibition decreases and the time taken for each bubble to form increases, slightly increasing the pressure at which snap-off occurs. The snap-off curvature is only about two-thirds of the curvature of a theoretical cylindrical meniscus within the large tube and about 40% of the curvature of the actual meniscus spanning the large tube.

  16. Charging machine

    DOEpatents

    Medlin, John B.

    1976-05-25

    A charging machine for loading fuel slugs into the process tubes of a nuclear reactor includes a tubular housing connected to the process tube, a charging trough connected to the other end of the tubular housing, a device for loading the charging trough with a group of fuel slugs, means for equalizing the coolant pressure in the charging trough with the pressure in the process tubes, means for pushing the group of fuel slugs into the process tube and a latch and a seal engaging the last object in the group of fuel slugs to prevent the fuel slugs from being ejected from the process tube when the pusher is removed and to prevent pressure liquid from entering the charging machine.

  17. Acquired tracheoesophageal fistula due to high intracuff pressure.

    PubMed

    Hameed, Akmal A; Mohamed, Hasan; Al-Mansoori, Motasem

    2008-01-01

    High-compliance endotracheal tube cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage and lead to tracheoesophageal fistula.Tracheostomy tube cuffs seal against the tracheal wall and prevent leakage of air around the tube, assuring that the tidal volume is delivered to the lungs. In the past, high-pressure cuffs were used, but these contributed to tracheal injury and have been replaced by high-volume, low-pressure cuffs. For long-term applications, some newer tubes have low-profile (tight to shaft) cuffs that facilitate the tracheostomy tube changes by eliminating the lip that forms when standard cuffs are deflated.

  18. High spatial resolution measurements of ram accelerator gas dynamic phenomena

    NASA Technical Reports Server (NTRS)

    Hinkey, J. B.; Burnham, E. A.; Bruckner, A. P.

    1992-01-01

    High spatial resolution experimental tube wall pressure measurements of ram accelerator gas dynamic phenomena are presented. The projectile resembles the centerbody of a ramjet and travels supersonically through a tube filled with a combustible gaseous mixture, with the tube acting as the outer cowling. Pressure data are recorded as the projectile passes by sensors mounted in the tube wall at various locations along the tube. Data obtained by using a special highly instrumented section of tube has allowed the recording of gas dynamic phenomena with a spatial resolution on the order of one tenth the projectile length. High spatial resolution tube wall pressure data from the three regimes of propulsion studied to date (subdetonative, transdetonative, and superdetonative) are presented and reveal the 3D character of the flowfield induced by projectile fins and the canting of the projectile body relative to the tube wall. Also presented for comparison to the experimental data are calculations made with an inviscid, 3D CFD code.

  19. Fabrication of stainless steel clad tubing. [gas pressure bonding

    NASA Technical Reports Server (NTRS)

    Kovach, C. W.

    1978-01-01

    The feasibility of producing stainless steel clad carbon steel tubing by a gas pressure bonding process was evaluated. Such a tube product could provide substantial chromium savings over monolithic stainless tubing in the event of a serious chromium shortage. The process consists of the initial assembly of three component tubesets from conventionally produced tubing, the formation of a strong metallurgical bond between the three components by gas pressure bonding, and conventional cold draw and anneal processing to final size. The quality of the tubes produced was excellent from the standpoint of bond strength, mechanical, and forming properties. The only significant quality problem encountered was carburization of the stainless clad by the carbon steel core which can be overcome by further refinement through at least three different approaches. The estimated cost of clad tubing produced by this process is greater than that for monolithic stainless tubing, but not so high as to make the process impractical as a chromium conservation method.

  20. [Prehospital airway management of laryngeal tubes. Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?].

    PubMed

    Dengler, V; Wilde, P; Byhahn, C; Mack, M G; Schalk, R

    2011-02-01

    Laryngeal tubes (LT) are increasingly being used for emergency airway management. This article reports on two patients in whom out-of-hospital intubation with a single-lumen LT was associated with massive pulmonary aspiration in one patient and gastric overinflation in the other. In both cases peak inspiratory pressures exceeded the LT leak pressure of approximately 35 mbar. This resulted in gastric inflation and decreased pulmonary compliance and increased inspiratory pressure further, thereby creating a vicious circle. It is therefore recommended that laryngeal tube suction (LTS) should be used in all cases of emergency airway management and a gastric drain tube be inserted through the dedicated second lumen. Apart from gastric overinflation, incorrect LT/LTS placement must be detected and immediately corrected, e.g. in cases of difficult or impossible gastric tube placement, permanent drainage of air from the gastric tube, decreasing minute ventilation or an ascending capnography curve.

  1. Resonance tube phonation in water: High-speed imaging, electroglottographic and oral pressure observations of vocal fold vibrations--a pilot study.

    PubMed

    Granqvist, Svante; Simberg, Susanna; Hertegård, Stellan; Holmqvist, Sofia; Larsson, Hans; Lindestad, Per-Åke; Södersten, Maria; Hammarberg, Britta

    2015-10-01

    Phonation into glass tubes ('resonance tubes'), keeping the free end of the tube in water, has been a frequently used voice therapy method in Finland and more recently also in other countries. The purpose of this exploratory study was to investigate what effects tube phonation with and without water has on the larynx. Two participants were included in the study. The methods used were high-speed imaging, electroglottographic observations of vocal fold vibrations, and measurements of oral pressure during tube phonation. Results showed that the fluctuation in the back pressure during tube phonation in water altered the vocal fold vibrations. In the high-speed imaging, effects were found in the open quotient and amplitude variation of the glottal opening. The open quotient increased with increasing water depth (from 2 cm to 6 cm). A modulation effect by the water bubbles on the vocal fold vibrations was seen both in the high-speed glottal area tracings and in the electroglottography signal. A second experiment revealed that the increased average oral pressure was largely determined by the water depth. The increased open quotient can possibly be explained by an increased abduction of the vocal folds and/or a reduced transglottal pressure. The back pressure of the bubbles also modulates glottal vibrations with a possible 'massage' effect on the vocal folds. This effect and the well-defined average pressure increase due to the known water depth are different from those of other methods using a semi-occluded vocal tract.

  2. Characterizing the active opening of the eustachian tube in a hypobaric/hyperbaric pressure chamber.

    PubMed

    Mikolajczak, Stefanie; Meyer, Moritz Friedo; Hahn, Moritz; Korthäuer, Christine; Jumah, Masen Dirk; Hüttenbrink, Karl-Bernd; Grosheva, Maria; Luers, Jan Christoffer; Beutner, Dirk

    2015-01-01

    Active and passive opening of the Eustachian tube (ET) enables direct aeration of the middle ear and a pressure balance between middle ear and the ambient pressure. The aim of this study was to characterize standard values for the opening pressure (ETOP), the opening frequency (ETOF), and the opening duration (ETOD) for active tubal openings (Valsalva maneuver, swallowing) in healthy participants. In a hypobaric/hyperbaric pressure chamber, 30 healthy participants (19 women, 11 men; mean age, 25.57 ± 3.33 years) were exposed to a standardized profile of compression and decompression. The pressure values were recorded via continuous impedance measurement during the Valsalva maneuver and swallowing. Based on the data, standard curves were identified and the ETOP, ETOD, and ETOF were determined. Recurring patterns of the pressure curve during active tube opening for the Valsalva maneuver and for active swallowing were characterized. The mean value for the Valsalva maneuver for ETOP was 41.21 ± 17.38 mbar; for the ETOD, it was 2.65 ± 1.87 seconds. In the active pressure compensation by swallowing, the mean value for the ETOP was 29.91 ± 13.07 mbar; and for the ETOD, it was 0.82 ± 0.53 seconds. Standard values for the opening pressure of the tube and the tube opening duration for active tubal openings (Valsalva maneuver, swallowing) were described, and typical curve gradients for healthy subjects could be shown. This is another step toward analyzing the function of the tube in compression and decompression.

  3. Characterizing pressure issues due to turbulent flow in tubing, in ultra-fast chiral supercritical fluid chromatography at up to 580bar.

    PubMed

    Berger, Terry A

    2016-12-02

    It has been widely suggested that the outlet pressure be changed to maintain constant density ("isopycnic" conditions) when comparing the kinetic performance of different columns in supercritical fluid chromatography (SFC). However, at high flow rates, flow in the tubing is turbulent, causing large extra-column pressure drops that limit options for changing outlet pressure. Some of these pressure drops occur before and some after the column, obscuring the actual column inlet and outlet pressures. In this work, a 4.6×100mm, 1.8μm R,R-Whelk-O1 column was used with low dispersion LD (120μm) plumbing to generate sub-1min chiral separations. However, the optimum, or near optimum, flow rate was 5mL-min -1 , producing a system pressure of 580bar (with 40% methanol, outlet pressure 120bar). Both the flow rate and pump pressure required were near the limits of the instrument, and significantly exceeded the capability of many other SFC's. Extra-column pressure drops (ΔP ec ) were as high as 200bar, caused mostly by turbulent flow in the tubing. The ΔP ec increased by more than the square of the flow rate. Reynolds Numbers (Re) were calculated for tubing as a function of flow rate between 100 and 400bar and 5-20% methanol in CO 2 , and 40°-60°C. This represents the most extensive analysis of turbulence in tubing in the SFC literature. Flow in 120μm ID tubing was calculated to be laminar below 1.0mL-min -1 , mostly transitional up to 2.5mL-min -1 and virtually always turbulent at 3mL-min -1 and higher. Flow in 170μm tubing is turbulent at lower flows but generates half the ΔP ec due to the lower mobile phase linear velocity. The results suggest that, while sub-minute chromatograms are easily generated, 4.6mm columns are not very user friendly for use with sub-2μm packings. The high flow rates required just to reach optimum result in high ΔP ec generated by the tubing, causing uncertainty in the true column inlet, outlet, and average column pressure/density. When comparing kinetic performance of columns with different dimensions, the pressure drops in the tubing must be considered. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Does Flexible Arterial Tubing Retain More Hemodynamic Energy During Pediatric Pulsatile Extracorporeal Life Support?

    PubMed

    Wang, Shigang; Kunselman, Allen R; Ündar, Akif

    2017-01-01

    The objective of this study was to evaluate the hemodynamic performance and energy transmission of flexible arterial tubing as the arterial line in a simulated pediatric pulsatile extracorporeal life support (ECLS) system. The ECLS circuit consisted of a Medos Deltastream DP3 diagonal pump head, Medos Hilite 2400 LT oxygenator, Biomedicus arterial/venous cannula (10 Fr/14 Fr), 3 feet of polyvinyl chloride (PVC) arterial tubing or latex rubber arterial tubing, primed with lactated Ringer's solution and packed red blood cells (hematocrit 40%). Trials were conducted at flow rates of 300 to 1200 mL/min (300 mL/min increments) under nonpulsatile and pulsatile modes at 36°C using either PVC arterial tubing (PVC group) or latex rubber tubing (Latex group). Real-time pressure and flow data were recorded using a custom-based data acquisition system. Mean pressures and energy equivalent pressures (EEP) were the same under nonpulsatile mode between the two groups. Under pulsatile mode, EEPs were significantly great than mean pressure, especially in the Latex group (P < 0.05). There was no difference between the two groups with regards to pressure drops across ECLS circuit, but pulsatile flow created more pressure drops than nonpulsatile flow (P < 0.05). Surplus hemodynamic energy (SHE) levels were always higher in the Latex group than in the PVC group at all sites. Although total hemodynamic energy (THE) losses were higher under pulsatile mode compared to nonpulsatile mode, more THE was delivered to the pseudopatient, particularly in the Latex group (P < 0.05). The results showed that the flexible arterial tubing retained more hemodynamic energy passing through it under pulsatile mode while mean pressures and pressure drops across the ECLS circuit were similar between PVC and latex rubber arterial tubing. Further studies are warranted to verify our findings. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. [In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes].

    PubMed

    Coelho, Rafael de Macedo; Paiva, Thiago Trigueiro Morais de; Mathias, Ligia Andrade da Silva Telles

    2016-01-01

    Cuffs of tracheal tubes protect the lower airway from aspiration of gastric contents and facilitate ventilation, but may cause many complications, especially when the cuff pressure exceeds 30cm H2O. This occurs in over 30% of conventional insufflations, so it is recommended to limit this pressure. In this study we evaluated the in vitro effectiveness of a method of limiting the cuff pressure to a range between 20 and 30cm H2O. Using an adapter to connect the tested tube to the anesthesia machine, the relief valve was regulated to 30cm H2O, inflating the cuff by operating the rapid flow of oxygen button. There were 33 trials for each tube of three manufacturers, of five sizes (6.5 to 8.5), using three times inflation (10, 15 and 20seconds), totaling 1485 tests. After inflation, the pressure obtained was measured with a manometer. Pressure >30cm H2O or <20cm H2O were considered failures. There were eight failures (0.5%, 95% CI: 0.1-0.9%), with all by pressures <20cm H2O and after 10seconds inflation (1.6%, 95% CI: 0 5-2.7%). One failure occurred with a 6.5 tube (0.3%, 95% CI: -0.3-0.9%), six with 7.0 tubes (2%, 95% CI: 0.4 to 3.6%), and one with a 7.5 tube (0.3%, 95% CI: -0.3-0.9%). This method was effective for inflating tracheal tube cuffs of different sizes and manufacturers, limiting its pressure to a range between 20 and 30cm H2O, with a success rate of 99.5% (95% CI: 99.1-99.9%). Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  6. In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes.

    PubMed

    Coelho, Rafael de Macedo; de Paiva, Thiago Trigueiro Morais; da Silva Telles Mathias, Ligia Andrade

    2016-01-01

    Cuffs of tracheal tubes protect the lower airway from aspiration of gastric contents and facilitate ventilation, but may cause many complications, especially when the cuff pressure exceeds 30cm H2O. This occurs in over 30% of conventional insufflations, so it is recommended to limit this pressure. In this study we evaluated the in vitro effectiveness of a method of limiting the cuff pressure to a range between 20 and 30cm H2O. Using an adapter to connect the tested tube to the anesthesia machine, the relief valve was regulated to 30cm H2O, inflating the cuff by operating the rapid flow of oxygen button. There were 33 trials for each tube of three manufacturers, of five sizes (6.5-8.5), using three times inflation (10, 15 and 20s), totaling 1485 tests. After inflation, the pressure obtained was measured with a manometer. Pressure >30cm H2O or <20cm H2O were considered failures. There were eight failures (0.5%, 95% CI: 0.1-0.9%), with all by pressures <20cm H2O and after 10s inflation (1.6%, 95% CI: 0 5-2.7%). One failure occurred with a 6.5 tube (0.3%, 95% CI: -0.3 to 0.9%), six with 7.0 tubes (2%, 95% CI: 0.4-3.6%), and one with a 7.5 tube (0.3%, 95% CI: -0.3 to 0.9%). This method was effective for inflating tracheal tube cuffs of different sizes and manufacturers, limiting its pressure to a range between 20 and 30cm H2O, with a success rate of 99.5% (95% CI: 99.1-99.9%). Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  7. Numerical and experimental study of a hydrodynamic cavitation tube

    NASA Astrophysics Data System (ADS)

    Hu, H.; Finch, J. A.; Zhou, Z.; Xu, Z.

    1998-08-01

    A numerical analysis of hydrodynamics in a cavitation tube used for activating fine particle flotation is described. Using numerical procedures developed for solving the turbulent k-ɛ model with boundary fitted coordinates, the stream function, vorticity, velocity, and pressure distributions in a cavitation tube were calculated. The calculated pressure distribution was found to be in excellent agreement with experimental results. The requirement of a pressure drop below approximately 10 m water for cavitation to occur was observed experimentally and confirmed by the model. The use of the numerical procedures for cavitation tube design is discussed briefly.

  8. Heat loss and drag of spherical drop tube samples

    NASA Technical Reports Server (NTRS)

    Wallace, D. B.

    1982-01-01

    Analysis techniques for three aspects of the performance of the NASA/MSFC 32 meter drop tube are considered. Heat loss through the support wire in a pendant drop sample, temperature history of a drop falling through the drop tube when the tube is filled with helium gas at various pressures, and drag and resulting g-levels experienced by a drop falling through the tube when the tube is filled with helium gas at various pressures are addressed. The developed methods apply to systems with sufficiently small Knudsen numbers for which continuum theory may be applied. Sample results are presented, using niobium drops, to indicate the magnitudes of the effects. Helium gas at one atmosphere pressure can approximately double the amount of possible undercooling but it results in an apparent gravity levels of up to 0.1 g.

  9. Vadose zone isobaric well

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2001-01-01

    A deep tensiometer is configured with an outer guide tube having a vented interval along a perforate section at its lower end, which is isolated from atmospheric pressure at or above grade. A transducer having a monitoring port and a reference port is located within a coaxial inner guide tube. The reference port of the transducer is open to the vented interval of the outer guide tube, which has the same gas pressure as in the sediment surrounding the tensiometer. The reference side of the pressure transducer is thus isolated from the effects of atmospheric pressure changes and relative to pressure changes in the material surrounding the tensiometer measurement location and so it is automatically compensated for such pressure changes.

  10. Hydrostatic Extrusion of 60mm Mortar Tubes

    DTIC Science & Technology

    1974-10-01

    Transverse "Tensile Test Specimen 16 9. Subsize Charpy and Tensile Test Specimens 17 10. Extruded 718 Alloy Tube Pressure-strain Pressure Test [)ata 18... subsize specimens. (d) Previous studies have shown that the standard size Charpy values are 4.5 times the subsize values. 22 -. •. ., *. ...20 II. Tensile Properties of Extruded and Aged Tube (a) 21 III. Extruded 718 Alloy Pressure Test Data 21 IV. V-Notch Charpy Impact Properties(c) of

  11. Results from sudden loss of vacuum on scaled superconducting radio frequency cryomodule experiment

    NASA Astrophysics Data System (ADS)

    Dalesandro, Andrew A.; Dhuley, Ram C.; Theilacker, Jay C.; Van Sciver, Steven W.

    2014-01-01

    Superconducting radio frequency (SRF) cavities for particle accelerators are at risk of failure due to sudden loss of vacuum (SLV) adjacent to liquid helium (LHe) spaces. To better understand this failure mode and its associated risks an experiment is designed to test the longitudinal effects of SLV within the beam tube of a scaled SRF cryomodule that has considerable length relative to beam tube cross section. The scaled cryomodule consists of six individual SRF cavities each roughly 350 mm long, initially cooled to 2 K by a superfluid helium bath and a beam tube pumped to vacuum. A fast-acting solenoid valve is used to simulate SLV on the beam tube, from which point it takes over 3 s for the beam tube pressure to equalize with atmosphere, and 30 s for the helium space to reach the relief pressure of 4 bara. A SLV longitudinal effect in the beam tube is evident in both pressure and temperature data, but interestingly the temperatures responds more quickly to SLV than do the pressures. It takes 500 ms (roughly 100 ms per cavity) for the far end of the 2 m long beam tube to respond to a pressure increase compared to 300 ms for temperature (approximately 50 ms per cavity). The paper expands upon these and other results to better understand the longitudinal effect for SRF cryomodules due to SLV.

  12. Crimp sealing of tubes flush with or below a fixed surface

    DOEpatents

    Fischer, J.E.; Walmsley, D.; Wapman, P.D.

    1996-08-20

    An apparatus for crimp sealing and severing tubes flush or below a fixed surface. Tube crimping below a fixed surface requires an asymmetric die and anvil configuration. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. This asymmetric die and anvil is used when a ductile metal tube and valve assembly are attached to a pressure vessel which has a fixed surface around the base of the tube at the pressure vessel. A flat anvil is placed against the tube. Die guides are placed against the tube on a side opposite the anvil. A pinch-off die is inserted into the die guides against the tube. Adequate clearance for inserting the die and anvil around the tube is needed below the fixed surface. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. 8 figs.

  13. Crimp sealing of tubes flush with or below a fixed surface

    DOEpatents

    Fischer, Jon E.; Walmsley, Don; Wapman, P. Derek

    1996-01-01

    An apparatus for crimp sealing and severing tubes flush or below a fixed surface. Tube crimping below a fixed surface requires an asymmetric die and anvil configuration. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. This asymmetric die and anvil is used when a ductile metal tube and valve assembly are attached to a pressure vessel which has a fixed surface around the base of the tube at the pressure vessel. A flat anvil is placed against the tube. Die guides are placed against the tube on a side opposite the anvil. A pinch-off die is inserted into the die guides against the tube. Adequate clearance for inserting the die and anvil around the tube is needed below the fixed surface. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes.

  14. High-Performance Ion Mobility Spectrometry Using Hourglass Electrodynamic Funnel And Internal Ion Funnel

    DOEpatents

    Smith, Richard D.; Tang, Keqi; Shvartsburg, Alexandre A.

    2004-11-16

    A method and apparatus enabling increased sensitivity in ion mobility spectrometry/mass spectrometry instruments which substantially reduces or eliminates the loss of ions in ion mobility spectrometer drift tubes utilizing an hourglass electrodynamic ion funnel at the entrance to the drift tube and/or an internal ion funnel at the exit of the drift tube. An hourglass electrodynamic funnel is formed of at least an entry element, a center element, and an exit element, wherein the aperture of the center element is smaller than the aperture of the entry element and the aperture of the exit elements. Ions generated in a relatively high pressure region by an ion source at the exterior of the hourglass electrodynamic funnel are transmitted to a relatively low pressure region at the entrance of the hourglass funnel through a conductance limiting orifice. Alternating and direct electrical potentials are applied to the elements of the hourglass electrodynamic funnel thereby drawing ions into and through the hourglass electrodynamic funnel thereby introducing relatively large quantities of ions into the drift tube while maintaining the gas pressure and composition at the interior of the drift tube as distinct from those at the entrance of the electrodynamic funnel and allowing a positive gas pressure to be maintained within the drift tube, if desired. An internal ion funnel is provided within the drift tube and is positioned at the exit of said drift tube. The advantage of the internal ion funnel is that ions that are dispersed away from the exit aperture within the drift tube, such as those that are typically lost in conventional drift tubes to any subsequent analysis or measurement, are instead directed through the exit of the drift tube, vastly increasing the amount of ions exiting the drift tube.

  15. Effects of the Fabrication Process and Thermal Cycling on the Oxidation of Zirconium-Niobium Pressure Tubes

    NASA Astrophysics Data System (ADS)

    Nam, Cheol

    2009-12-01

    Pressure tubes made of Zr-2.5%Nb alloy are used to contain fuels and coolant in CANDU nuclear power reactors The pressure tube oxidizes during reactor operation and hydrogen ingress through the oxide grown on the tube limits its lifetime. Little attention was paid to the intermediate tube manufacturing processes in enhancing the oxidation resistance. In addition, the oxide grown on the tube experiences various thermal cycles depending on the reactor shutdown and startup cycles. To address these two aspects and to better understand the oxidation process of the Zr-2.5Nb tube, research was conducted in two parts: (i) effects of tube fabrication on oxidation behavior, and (ii) thermal cycling behaviors of oxides grown on a pressure tube. In the first part, the optimum manufacturing process was pursued to improve the corrosion resistance of Zr-2.5Nb tubes. Experimental micro-tubes were fabricated with various manufacturing routes in the stages of billet preparation, hot extrusion and cold drawing. These were oxidized in air at 400°C and 500°C, and in an autoclave at 360°C lithiated water. Microstructure and texture of the tubes and oxides were characterized with X-ray diffraction, scanning electron microscope and optical microscope. Special emphasis was given to examinations of the metal/oxide interface structures. A correlation between the manufacturing process and oxidation resistance was investigated in terms of tube microstructure and the metal/oxide interface structure. As a result, it was consistently observed that uniform interface structures were formed on the tubes which had a fine distribution of secondary phases. These microstructures were found to be beneficial in enhancing the oxidation resistance as opposed to the tubes that had coarse and continuous beta-Zr phases. Based on these observations, a schematic model of the oxidation process was proposed with respect to the oxidation resistance under oxidizing temperatures of 360°C, 400°C and 500°C. In the second part, the oxides grown on a standard Zr-2.5Nb pressure tube were analyzed by X-ray diffraction peak broadening and line shift. Crystallite size, t-ZrO2 fraction and residual stress of the zirconium oxides were investigated upon several thermal cycles at DeltaT range of 500°C--750°C. The oxide residual stresses measured by the sin2psi method were always compressive around 2 GPa. Different stress-states were noticed with the oxides grown on different sections of pressure tube. The compressive stress was released when the oxide was thermally cycled at the highest DeltaT of 750°C. Discussion was given to the effects of anisotropic nature of thermal expansion coefficients and crystallographic texture on the stress-state of Zr oxides.

  16. Small drill-hole, gas mini-permeameter probe

    DOEpatents

    Molz, III, Fred J.; Murdoch, Lawrence C.; Dinwiddie, Cynthia L.; Castle, James W.

    2002-12-03

    The distal end of a basic tube element including a stopper device with an expandable plug is positioned in a pre-drilled hole in a rock face. Rotating a force control wheel threaded on the tube element exerts force on a sleeve that in turn causes the plug component of the stopper means to expand and seal the distal end of the tube in the hole. Gas under known pressure is introduced through the tube element. A thin capillary tube positioned in the tube element connects the distal end of the tube element to means to detect and display pressure changes and data that allow the permeability of the rock to be determined.

  17. Small drill-hole, gas mini-permeameter probe

    DOEpatents

    Molz, III, Fred J.; Murdoch, Lawrence C.; Dinwiddie, Cynthia L.; Castle, James W.

    2002-01-01

    The distal end of a basic tube element including a stopper device with an expandable plug is positioned in a pre-drilled hole in a rock face. Rotating a force control wheel threaded on the tube element exerts force on a sleeve that in turn causes the plug component of the stopper means to expand and seal the distal end of the tube in the hole. Gas under known pressure is introduced through the tube element. A thin capillary tube positioned in the tube element connects the distal end of the tube element to means to detect and display pressure changes and data that allow the permeability of the rock to be determined.

  18. 78 FR 32551 - Airworthiness Directives; Turbomeca S.A. Turboshaft Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-31

    ... manifolds and borescope- inspection of the flame tube and the high-pressure (HP) turbine area for possible...-inspect the flame tube and the high-pressure turbine area for turbine distress, when replacing the fuel... installation before exceeding 400 operating hours TSN. (2) Borescope-inspect the flame tube and the high...

  19. Manufacture of thin-walled clad tubes by pressure welding of roll bonded sheets

    NASA Astrophysics Data System (ADS)

    Schmidt, Hans Christian; Grydin, Olexandr; Stolbchenko, Mykhailo; Homberg, Werner; Schaper, Mirko

    2017-10-01

    Clad tubes are commonly manufactured by fusion welding of roll bonded metal sheets or, mechanically, by hydroforming. In this work, a new approach towards the manufacture of thin-walled tubes with an outer diameter to wall thickness ratio of about 12 is investigated, involving the pressure welding of hot roll bonded aluminium-steel strips. By preparing non-welded edges during the roll bonding process, the strips can be zip-folded and (cold) pressure welded together. This process routine could be used to manufacture clad tubes in a continuous process. In order to investigate the process, sample tube sections with a wall thickness of 2.1 mm were manufactured by U-and O-bending from hot roll bonded aluminium-stainless steel strips. The forming and welding were carried out in a temperature range between RT and 400°C. It was found that, with the given geometry, a pressure weld is established at temperatures starting above 100°C. The tensile tests yield a maximum bond strength at 340°C. Micrograph images show a consistent weld of the aluminium layer over the whole tube section.

  20. Corrosion evaluation of N reactor pressure tube 1756

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larrick, A.P.

    1967-10-26

    N Reactor Zircaloy-2 pressure tube No. 1756 and its associated ASTM A234 steel nozzles were examined for corrosion and hydrogen content after approximately 300 days exposure in-reactor. Visual examination showed tight, adherent, dull black oxides in the pressure tube except for scratching in the bottom due to sliding of fuel and fuel spacers through the tube during charge- discharge operations. Several fretted areas up to $sup 3$/$sub 8$ inch wide by $sup 1$/$sub 2$ inch long by up to 13 mils deep were observed at the downstream end--these pits were caused by vibration of the fuel spacers against the pressuremore » tube. Hydrogen levels were fairly constant along the tube length with an average of about 19 +- 6 ppm except at one location. At approximately 30 inches from the front end of the tube a sharp peak to a maximum of 58 ppm hydrogen occurred. The reason for the peak is unknown. (auth)« less

  1. ANSYS Fluent Modelling of an Underexpanded Supersonic Sootblower Jet Impinging into Recovery Boiler Tube Geometries

    NASA Astrophysics Data System (ADS)

    Doroudi, Shahed

    Sootblowers generate high pressure supersonic steam jets to control fireside deposition on heat transfer tubes of a kraft recovery boiler. Sootblowing is energy expensive, using 3-12% of the mill's total steam production. This motivates research on the dynamics of sootblower jet interaction with tubes and deposits, to optimize their use. A CFD investigation was performed using ANSYS Fluent 15.0 to model three-dimensional steady-state impingement of a Mach 2.5 mildly underexpanded (PR 1.2) air jet onto arrays of cylindrical tubes with and without fins, at various nozzle-to-tube centerline offsets. A free jet and four impingement cases for each of the economizer and generating bank geometries are compared to experimental visualizations. Pressure distributions on impinging surfaces suggest that the fins in the economizer produce a reduced but uniform sootblowing force. Pressure contours along the tubes (in the vertical direction) show a sharp decline one tube diameter away from the jet mid-plane.

  2. Preliminary Investigation of the Process Capabilities of Hydroforging

    PubMed Central

    Alzahrani, Bandar; Ngaile, Gracious

    2016-01-01

    Hydroforging is a hybrid forming operation whereby a thick tube is formed to a desired geometry by combining forging and hydroforming principles. Through this process hollow structures with high strength-to-weight ratio can be produced for applications in power transmission systems and other structural components that demands high strength-to-weight ratio. In this process, a thick tube is deformed by pressurized fluid contained within the tube using a multi-purpose punch assembly, which is also used to feed tube material into the die cavity. Fluid pressure inside the thick tube is developed by volume change governed by the movement of the punch assembly. In contrast to the conventional tube hydroforming (THF), the hydroforging process presented in this study does not require external supply of pressurized fluid to the deforming tube. To investigate the capability of hydroforging process, an experimental setup was developed and used to hydroforge various geometries. These geometries included hollow flanged vessels, hexagonal flanged parts, and hollow bevel and spur gears. PMID:28787840

  3. Numerical modeling and characterization of blast waves for application in blast-induced mild traumatic brain injury research

    NASA Astrophysics Data System (ADS)

    Phillips, Michael G.

    Human exposure to blast waves, including blast-induced traumatic brain injury, is a developing field in medical research. Experiments with explosives have many disadvantages including safety, cost, and required area for trials. Shock tubes provide an alternative method to produce free field blast wave profiles. A compressed nitrogen shock tube experiment instrumented with static and reflective pressure taps is modeled using a numerical simulation. The geometry of the numerical model is simplified and blast wave characteristics are derived based upon static and pressure profiles. The pressure profiles are analyzed along the shock tube centerline and radially away from the tube axis. The blast wave parameters found from the pressure profiles provide guidelines for spatial location of a specimen. The location could be based on multiple parameters and provides a distribution of anticipated pressure profiles experience by the specimen.

  4. Injector Element which Maintains a Constant Mean Spray Angle and Optimum Pressure Drop During Throttling by Varying the Geometry of Tangential Inlets

    NASA Technical Reports Server (NTRS)

    Trinh, Huu P. (Inventor); Myers, William Neill (Inventor)

    2014-01-01

    A method for determining the optimum inlet geometry of a liquid rocket engine swirl injector includes obtaining a throttleable level phase value, volume flow rate, chamber pressure, liquid propellant density, inlet injector pressure, desired target spray angle and desired target optimum delta pressure value between an inlet and a chamber for a plurality of engine stages. The tangential inlet area for each throttleable stage is calculated. The correlation between the tangential inlet areas and delta pressure values is used to calculate the spring displacement and variable inlet geometry. An injector designed using the method includes a plurality of geometrically calculated tangential inlets in an injection tube; an injection tube cap with a plurality of inlet slots slidably engages the injection tube. A pressure differential across the injector element causes the cap to slide along the injection tube and variably align the inlet slots with the tangential inlets.

  5. Dynamic loads on human and animal surrogates at different test locations in compressed-gas-driven shock tubes

    NASA Astrophysics Data System (ADS)

    Alay, E.; Skotak, M.; Misistia, A.; Chandra, N.

    2018-01-01

    Dynamic loads on specimens in live-fire conditions as well as at different locations within and outside compressed-gas-driven shock tubes are determined by both static and total blast overpressure-time pressure pulses. The biomechanical loading on the specimen is determined by surface pressures that combine the effects of static, dynamic, and reflected pressures and specimen geometry. Surface pressure is both space and time dependent; it varies as a function of size, shape, and external contour of the specimens. In this work, we used two sets of specimens: (1) anthropometric dummy head and (2) a surrogate rodent headform instrumented with pressure sensors and subjected them to blast waves in the interior and at the exit of the shock tube. We demonstrate in this work that while inside the shock tube the biomechanical loading as determined by various pressure measures closely aligns with live-fire data and shock wave theory, significant deviations are found when tests are performed outside.

  6. 30 CFR 250.528 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... calculated MAWOPs; (h) All casing/riser pre-bleed down pressures; (i) Shut-in tubing pressure; (j) Flowing tubing pressure; (k) Date and the calculated daily production rate during last well test (oil, gas, basic...); (m) Well type (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well schematic; (p...

  7. 30 CFR 250.527 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... calculated MAWOPs; (h) All casing/riser pre-bleed down pressures; (i) Shut-in tubing pressure; (j) Flowing tubing pressure; (k) Date and the calculated daily production rate during last well test (oil, gas, basic...); (m) Well type (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well schematic; (p...

  8. 30 CFR 250.528 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... calculated MAWOPs; (h) All casing/riser pre-bleed down pressures; (i) Shut-in tubing pressure; (j) Flowing tubing pressure; (k) Date and the calculated daily production rate during last well test (oil, gas, basic...); (m) Well type (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well schematic; (p...

  9. FERRET-SAND II physics-dosimetry analysis for N Reactor Pressure Tubes 2954, 3053 and 1165 using a WIMS calculated input spectrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McElroy, W.N.; Kellogg, L.S.; Matsumoto, W.Y.

    1988-05-01

    This report is in response to a request from Westinghouse Hanford Company (WHC) that the PNL National Dosimetry Center (NDC) perform physics-dosimetry analyses (E > MeV) for N Reactor Pressure Tubes 2954 and 3053. As a result of these analyses, and recommendations for additional studies, two physics-dosimetry re-evaluations for Pressure Tube 1165 were also accomplished. The primary objective of Pacific Northwest Laboratories' (PNL) National Dosimetry Center (NDC) physics-dosimetry work for N Reactor was to provide FERRET-SAND II physics-dosimetry results to assist in the assessment of neutron radiation-induced changes in the physical and mechanical properties of N Reactor pressure tubes. 15more » refs., 6 figs., 5 tabs.« less

  10. Shock wave propagation in a magnetic flux tube

    NASA Astrophysics Data System (ADS)

    Ferriz-Mas, A.; Moreno-Insertis, F.

    1992-12-01

    The propagation of a shock wave in a magnetic flux tube is studied within the framework of the Brinkley-Kirkwood theory adapted to a radiating gas. Simplified thermodynamic paths along which the compressed plasma returns to its initial state are considered. It is assumed that the undisturbed medium is uniform and that the flux tube is optically thin. The shock waves investigated, which are described with the aid of the thin flux-tube approximation, are essentially slow magnetohydrodynamic shocks modified by the constraint of lateral pressure balance between the flux tube and the surrounding field-free fluid; the confining external pressure must be balanced by the internal gas plus magnetic pressures. Exact analytical solutions giving the evolution of the shock wave are obtained for the case of weak shocks.

  11. Water Drinking Test: Intraocular Pressure Changes after Tube Surgery and Trabeculectomy

    PubMed Central

    Razeghinejad, Mohammad Reza; Tajbakhsh, Zahra; Nowroozzadeh, Mohammad Hossein; Masoumpour, Masoumeh

    2017-01-01

    Purpose: To study the effects of filtration surgeries (tube and trabeculectomy) on changes in intraocular pressure after a water-drinking test. Methods: In this prospective, non-randomized, comparative clinical study, 30 patients who had tube surgery and 30 age- and sex-matched trabeculectomy patients underwent a water-drinking test. Only one eye of each patient was included. The baseline intraocular pressure was ≤21 mmHg in all enrolled eyes with or without adjunctive topical medications. After the water-drinking test, the intraocular pressure was measured and recorded at 15, 30, 45, and 60 minutes and the results were compared between the two groups. Results: In both groups, intraocular pressure significantly increased from baseline at all measured time-points (P < 0.001). In the trabeculectomy group, the average intraocular pressure increased from 14.8 ± 2.9 to 18.8 ± 4.7 mmHg at 30 minutes, but decreased at 60 min (18.0 ± 5.2 mmHg). In the Tube group, intraocular pressure increased incrementally until the last measurement (14.2 ± 3.9, 18.8 ± 5.6, and 19.7 ± 6.0 mmHg at baseline, 30, and 60 minutes, respectively). The end-pressure difference (intraocular pressure at 60 minutes vs. baseline) was significantly greater in the tube group (5.6 ± 3.6 mmHg; 41% change) than in the trabeculectomy group (3.2 ± 4.7; 23% change; P = 0.03). Conclusion: Intraocular pressure significantly increased after the water-drinking test in both the groups. Intraocular pressure started to decline 30 minutes after the water-drinking test in the trabeculectomy group, while it continued to increase up to 60 minutes in the Tube group. This finding may have implications regarding the efficacy or safety of the procedures in advanced glaucoma patients. PMID:29090048

  12. DEVICE FOR CHARGING OR DISCHARGING

    DOEpatents

    Untemeyer, S.; Hutter, E.

    1959-01-13

    A loading and unloading device is presented for loading objects into and unloading them from an apparatus in which fluid under pressure is employed, such as a heterogeneous rcactor wherein the fuel elements are in the form of slugs. This device is comprised essentially of a cylindrical member disposed coaxially with and as an accessible extension of an internal tube member of the apparatus in which the objects, or fuel elements, are normally disposed in use. The outermost end of the cylindrical extension is closed by a removable seal plug. The lower end of the cylindrical extension is separated from the intennal tube by a disk valve which is operated externally. A source of pressure fluid and a drain line are provided in communication with the interior of the cylindrical extension. To load an object into the internal tube, the disk valve is closed, the seal plug is renmoved, an object is placed in the cylindrical extension, and the seal plug is replaced. The disk valve is then opened and ihe pressure of the fluid within the cylindrical extension is increased until it is greater than the pressure within the internal tube and forces the object out of the cylindrical extension into the internal tube. To remove an object from the tube the disk valve is opened and the intenior of thc cylindnical extension is connected to the drain line whereby the operating pressure within the intennal tube forces the object out of the internal tube and up into the cylindrical extension. The disk valve is then closed and the seal plug is removed to permit removal of the object.

  13. High frequency pressure oscillator for microcryocoolers.

    PubMed

    Vanapalli, S; ter Brake, H J M; Jansen, H V; Zhao, Y; Holland, H J; Burger, J F; Elwenspoek, M C

    2008-04-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80 K, delivering a cooling power of 10 mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5 MPa and compression volume of about 22.6 mm(3) when operating the actuator with a peak-to-peak sinusoidal voltage of 100 V at a frequency of 1 kHz. The electrical power input was 2.73 W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.

  14. High frequency pressure oscillator for microcryocoolers

    NASA Astrophysics Data System (ADS)

    Vanapalli, S.; ter Brake, H. J. M.; Jansen, H. V.; Zhao, Y.; Holland, H. J.; Burger, J. F.; Elwenspoek, M. C.

    2008-04-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80K, delivering a cooling power of 10mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5MPa and compression volume of about 22.6mm3 when operating the actuator with a peak-to-peak sinusoidal voltage of 100V at a frequency of 1kHz. The electrical power input was 2.73W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.

  15. Pressure dependence of the radial mode frequency in carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Venkateswaran, Uma; Masica, D.; Sumanasekara, G.; Eklund, P.

    2003-03-01

    Recently, an analytical expression for the radial breathing mode frequency, ω_R, was derived by considering the oscillations of a thin hollow cylinder.[1] Using this result and the experimental pressure-dependence of the elastic and lattice constants of graphite, we show that the pressure derivative of ωR depends inversely on the nanotube diameter, D. Since ωR also depends inversely on D, the above result implies that the logarithmic pressure derivative of ω_R, i.e., dlnω_R/dP should be independent of D. We have performed high-pressure Raman scattering experiments on HiPCO-SWNT bundles using different laser excitations, thereby probing the radial modes from different diameter tubes. These measurements show an increase in dlnω_R/dP with increasing D. This difference between the predictions and experiments suggests that the main contribution to ω_R's pressure dependence in SWNT bundles stems from the tube-tube interactions within the bundle and from pressure-induced distortions to the tube cross-section. [1] G.D. Mahan, Phys. Rev. B 65, 235402 (2002).

  16. 46 CFR 56.30-25 - Flared, flareless, and compression fittings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... form a pressure seal against the fitting body. (e) For fluid services, other than hydraulic systems... within the service limitations of size, pressure, temperature, and vibration recommended by the... outer surface of the tube with sufficient strength to hold the tube against pressure, but without...

  17. 46 CFR 56.30-25 - Flared, flareless, and compression fittings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... form a pressure seal against the fitting body. (e) For fluid services, other than hydraulic systems... within the service limitations of size, pressure, temperature, and vibration recommended by the... outer surface of the tube with sufficient strength to hold the tube against pressure, but without...

  18. 46 CFR 56.30-25 - Flared, flareless, and compression fittings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... form a pressure seal against the fitting body. (e) For fluid services, other than hydraulic systems... within the service limitations of size, pressure, temperature, and vibration recommended by the... outer surface of the tube with sufficient strength to hold the tube against pressure, but without...

  19. 46 CFR 56.30-25 - Flared, flareless, and compression fittings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... form a pressure seal against the fitting body. (e) For fluid services, other than hydraulic systems... within the service limitations of size, pressure, temperature, and vibration recommended by the... outer surface of the tube with sufficient strength to hold the tube against pressure, but without...

  20. Hydrogen gas sensor and method of manufacture

    DOEpatents

    McKee, John M.

    1991-01-01

    A sensor for measuring the pressure of hydrogen gas in a nuclear reactor, and method of manufacturing the same. The sensor comprises an elongated tube of hydrogen permeable material which is connected to a pressure transducer through a feedthrough tube which passes through a wall at the boundary of the region in which hydrogen is present. The tube is pressurized and flushed with hydrogen gas at an elevated temperature during the manufacture of the sensor in order to remove all gasses other than hydrogen from the device.

  1. Burst strength of tubing and casing based on twin shear unified strength theory.

    PubMed

    Lin, Yuanhua; Deng, Kuanhai; Sun, Yongxing; Zeng, Dezhi; Liu, Wanying; Kong, Xiangwei; Singh, Ambrish

    2014-01-01

    The internal pressure strength of tubing and casing often cannot satisfy the design requirements in high pressure, high temperature and high H2S gas wells. Also, the practical safety coefficient of some wells is lower than the design standard according to the current API 5C3 standard, which brings some perplexity to the design. The ISO 10400: 2007 provides the model which can calculate the burst strength of tubing and casing better than API 5C3 standard, but the calculation accuracy is not desirable because about 50 percent predictive values are remarkably higher than real burst values. So, for the sake of improving strength design of tubing and casing, this paper deduces the plastic limit pressure of tubing and casing under internal pressure by applying the twin shear unified strength theory. According to the research of the influence rule of yield-to-tensile strength ratio and mechanical properties on the burst strength of tubing and casing, the more precise calculation model of tubing-casing's burst strength has been established with material hardening and intermediate principal stress. Numerical and experimental comparisons show that the new burst strength model is much closer to the real burst values than that of other models. The research results provide an important reference to optimize the tubing and casing design of deep and ultra-deep wells.

  2. Burst Strength of Tubing and Casing Based on Twin Shear Unified Strength Theory

    PubMed Central

    Lin, Yuanhua; Deng, Kuanhai; Sun, Yongxing; Zeng, Dezhi; Liu, Wanying; Kong, Xiangwei; Singh, Ambrish

    2014-01-01

    The internal pressure strength of tubing and casing often cannot satisfy the design requirements in high pressure, high temperature and high H2S gas wells. Also, the practical safety coefficient of some wells is lower than the design standard according to the current API 5C3 standard, which brings some perplexity to the design. The ISO 10400: 2007 provides the model which can calculate the burst strength of tubing and casing better than API 5C3 standard, but the calculation accuracy is not desirable because about 50 percent predictive values are remarkably higher than real burst values. So, for the sake of improving strength design of tubing and casing, this paper deduces the plastic limit pressure of tubing and casing under internal pressure by applying the twin shear unified strength theory. According to the research of the influence rule of yield-to-tensile strength ratio and mechanical properties on the burst strength of tubing and casing, the more precise calculation model of tubing-casing's burst strength has been established with material hardening and intermediate principal stress. Numerical and experimental comparisons show that the new burst strength model is much closer to the real burst values than that of other models. The research results provide an important reference to optimize the tubing and casing design of deep and ultra-deep wells. PMID:25397886

  3. In Vitro Evaluation of Evacuated Blood Collection Tubes as a Closed-Suction Surgical Drain Reservoir.

    PubMed

    Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly

    The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.

  4. Evaluation of a teaching tool to increase the accuracy of pilot balloon palpation for measuring tracheostomy tube cuff pressure.

    PubMed

    Jiang, Nancy; Del Signore, Anthony G; Iloreta, Alfred M; Malkin, Benjamin D

    2013-08-01

    The purpose of this study was to evaluate the efficacy of a novel teaching tool to improve health care providers' ability to inflate tracheostomy tube cuffs to the appropriate pressure. Single-blinded, randomized, controlled trial. Subjects were randomized to a control and study group. The control group viewed a video about inflating tracheostomy tube cuffs to safe pressure levels. The study group viewed the same video and also got to palpate the pilot balloons of tracheostomy tube cuffs inflated to three different pressures. All subjects inflated tracheostomy tube cuffs to pressures they believed to be appropriate based on palpation of the pilot balloon preintervention, and immediately, 2 weeks, and 3 months postintervention. Forty-nine health care providers participated in the study. There was no significant difference in the mean preintervention cuff inflation pressures between the two groups (36 cm H2 O vs. 38 cm H2 O, P = 0.4888), with both initially overinflating. Postintervention, the study group inflated the cuffs to significantly lower pressures than the control group, closer to the ideal of 25 cm H2 O (26 cm H2 O vs. 35 cm H2 O, P = 0.0001). This difference was also observed 2 weeks (28 cm H2 O vs. 37 cm H2 O P <0.0001) and 3 months (28 cm H2 O vs. 36 cm H2 O, P = 0.0002) postintervention. The novel teaching tool evaluated in this study is simple, easily reproducible, and low-cost. Its use leads to long-lasting improvement in health care providers' ability to more accurately inflate tracheostomy tube cuffs to safe pressures. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Impact of tubing length on hemodynamics in a simulated neonatal extracorporeal life support circuit.

    PubMed

    Qiu, Feng; Uluer, Mehmet C; Kunselman, Allen; Clark, J Brian; Myers, John L; Undar, Akif

    2010-11-01

    During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8Fr Biomedicus arterial and a 10Fr Biomedicus venous cannula were connected to the pseudopatient. One-fourth inch tubing was used for both the arterial and the venous line. A Hoffman clamp was located upstream from the pseudopatient to maintain a certain patient pressure. Three pressure transducers were placed at different sites: postoxygenator, prearterial cannula, and postarterial cannula. The system was primed with Lactated Ringer's solution; human blood was then added to maintain a hematocrit of 40%. The volume of the pseudopatient was 500mL. We hemodynamically evaluated three circuits with different lengths of tubing: 6, 4, and 2 feet (182.88, 121.92, and 60.96 cm, respectively) for both arterial and venous lines; the priming volumes including all of the components of the circuits were 195, 155, and 115mL, respectively. In each circuit, we measured the pressure drops of the arterial tubing and the arterial cannula, as well as the flow rates at different rpm (1750-3000, 250 intervals) under three patient pressures (40, 60, and 80mm Hg). All the experiments were conducted at 37°C. The pressure drop across the arterial cannula is much larger than that of arterial tubing in all set-ups, especially under high flow rates. Upon cutting the tubing from 6 to 2 feet, the pressure drop of the arterial tubing decreased by half, while the pressure drop of the arterial cannula increased due to the slightly higher flow rates. These results suggest that compared to the arterial tubing, the arterial cannula has a larger impact on the hemodynamics of the circuit. There is a little influence of tubing length on the circuit flow rate. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. 78 FR 9007 - Airworthiness Directives; Turbomeca S.A. Turboshaft Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-07

    ... replacement of injector manifolds and borescope-inspection of the flame tube and the high-pressure (HP...-inspect the flame tube and the high-pressure turbine area for turbine distress. (3) Thereafter, within... and the high-pressure turbine area for turbine distress. (3) Thereafter, within every 400 operating...

  7. Outflow resistance of the Baerveldt glaucoma drainage implant and modifications for early postoperative intraocular pressure control.

    PubMed

    Breckenridge, R Reid; Bartholomew, Luanna R; Crosson, Craig E; Kent, Alexander R

    2004-10-01

    To determine outflow resistance of the Baerveldt glaucoma implant using different tube configurations. Outflow resistance of 6 tube configurations (C1- C6) of Baerveldt implants was measured under conditions of constant pressure perfusion. Pressures ranged from 2 to 55 mm Hg. Venting slits were created using a 7-0 Vicryl, spatulated suture-needle. Seton tubes were occluded by threading a retrograde suture approximately 1.5 cm into the lumen. At pressures between 2 and 55 mm Hg, mean outflow resistance of the normally configured seton (ie, open tube; C1) was 0.41 (+/- 0.6) mm Hg/microL/min. Resistance was unchanged (mean 0.41 (+/- 0.4) mm Hg/microL/min) by the addition of 4 venting slits (C2) to the seton tube. Occlusion of the open seton tube with a 3-0 Supramid suture (C3) significantly increased (P < 0.001) mean outflow resistance to 14.99 (+/- 0.6) mm Hg/microL/min. Occlusion of the tube with a 4-0 Supramid suture (C4) significantly increased (P < 0.001) mean outflow resistance to 1.09 (+/- 0.5) mm Hg/microL/min. In implants where tubes were occluded with a 3-0 Supramid suture, the addition of venting slits (C5) significantly decreased (P = 0.038) mean outflow resistance to 8.98 (+/- 0.4) mm Hg/microL/min. In tubes occluded with a 4-0 Supramid suture, the addition of venting slits (C6) decreased mean outflow resistance to 0.98 (+/- 0.6) mm Hg/microL/min. Although these results cannot be directly correlated to the clinical setting, they do show that outflow resistance can be modified at the time of surgery by changing tube configuration of the Baerveldt glaucoma implant. Configuration C5 (3-0 Supramid with venting slits) closely approximates the outflow rate in the normal intraocular pressure range.

  8. Free-piston cutting machine

    DOEpatents

    Ciccarelli, Gaby; Subudhi, Manomohan; Hall, Robert E.

    2000-01-01

    A cutting machine includes a gun barrel for receiving a projectile. A compression tube is disposed in flow communication with the barrel and includes a piston therein. A reservoir is disposed in flow communication with the tube and receives a first gas under pressure. A second gas fills the compression tube on a front face of the piston. And, the pressurized first gas is discharged into the tube on a back face of the piston to accelerate the piston through the tube for compressing the second gas, and in turn launching the projectile through the barrel to impact a workpiece.

  9. Correlations to predict frictional pressure loss of hydraulic-fracturing slurry in coiled tubing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, S.; Zhoi, Y.X.; Bailey, M.

    2009-08-15

    Compared with conventional-tubing fracturing, coiled-tubing (CT) fracturing has several advantages. CT fracturing has become an effective stimulation technique for multizone oil and gas wells. It is also an attractive production-enhancement method for multiseam coalbed-methane wells, and wells with bypassed zones. The excessive frictional pressure loss through CT has been a concern in fracturing. The small diameter of the string limits the cross-sectional area open to flow. Furthermore, the tubing curvature causes secondary flow and results in extra flow resistance. This increased frictional pressure loss results in high surface pumping pressure. The maximum possible pump rate and sand concentration, therefore, havemore » to be reduced. To design a CT fracturing job properly, it is essential to predict the frictional pressure loss through the tubing accurately. This paper presents correlations for the prediction of frictional pressure loss of fracturing slurries in straight tubing and CT. They are developed on the basis of full-scale slurry-flow tests with 11/2-in. CT and slurries prepared with 35 lbm/1,000 gal of guar gel. The extensive experiments were conducted at the full-scale CT-flow test facility. The proposed correlations have been verified with the experimental data and actual field CT-fracturing data. Case studies of wells recently fractured are provided to demonstrate the application of the correlations. The correlations will be useful to the CT engineers in their hydraulics design calculations.« less

  10. Multistage open-tube trap for enrichment of part-per-trillion trace components of low-pressure (below 27-kPa) air samples

    NASA Technical Reports Server (NTRS)

    Ohara, D.; Vo, T.; Vedder, J. F.

    1985-01-01

    A multistage open-tube trap for cryogenic collection of trace components in low-pressure air samples is described. The open-tube design allows higher volumetric flow rates than densely packed glass-bead traps commonly reported and is suitable for air samples at pressures below 27 kPa with liquid nitrogen as the cryogen. Gas blends containing 200 to 2500 parts per trillion by volume each of ethane and ethene were sampled and hydrocarbons were enriched with 100 + or - 4 percent trap efficiency. The multistage design is more efficient than equal-length open-tube traps under the conditions of the measurements.

  11. On the Exit Boundary Condition for One-Dimensional Calculations of Pulsed Detonation Engine Performance

    NASA Technical Reports Server (NTRS)

    Wilson, Jack; Paxson, Daniel E.

    2002-01-01

    In one-dimensional calculations of pulsed detonation engine (PDE) performance, the exit boundary condition is frequently taken to be a constant static pressure. In reality, for an isolated detonation tube, after the detonation wave arrives at the exit plane, there will be a region of high pressure, which will gradually return to ambient pressure as an almost spherical shock wave expands away from the exit, and weakens. Initially, the flow is supersonic, unaffected by external pressure, but later becomes subsonic. Previous authors have accounted for this situation either by assuming the subsonic pressure decay to be a relaxation phenomenon, or by running a two-dimensional calculation first, including a domain external to the detonation tube, and using the resulting exit pressure temporal distribution as the boundary condition for one-dimensional calculations. These calculations show that the increased pressure does affect the PDE performance. In the present work, a simple model of the exit process is used to estimate the pressure decay time. The planar shock wave emerging from the tube is assumed to transform into a spherical shock wave. The initial strength of the spherical shock wave is determined from comparison with experimental results. Its subsequent propagation, and resulting pressure at the tube exit, is given by a numerical blast wave calculation. The model agrees reasonably well with other, limited, results. Finally, the model was used as the exit boundary condition for a one-dimensional calculation of PDE performance to obtain the thrust wall pressure for a hydrogen-air detonation in tubes of length to diameter ratio (L/D) of 4, and 10, as well as for the original, constant pressure boundary condition. The modified boundary condition had no performance impact for values of L/D > 10, and moderate impact for L/D = 4.

  12. Experimental study on the pressure and pulse wave propagation in viscoelastic vessel tubes-effects of liquid viscosity and tube stiffness.

    PubMed

    Ikenaga, Yuki; Nishi, Shohei; Komagata, Yuka; Saito, Masashi; Lagrée, Pierre-Yves; Asada, Takaaki; Matsukawa, Mami

    2013-11-01

    A pulse wave is the displacement wave which arises because of ejection of blood from the heart and reflection at vascular bed and distal point. The investigation of pressure waves leads to understanding the propagation characteristics of a pulse wave. To investigate the pulse wave behavior, an experimental study was performed using an artificial polymer tube and viscous liquid. A polyurethane tube and glycerin solution were used to simulate a blood vessel and blood, respectively. In the case of the 40 wt% glycerin solution, which corresponds to the viscosity of ordinary blood, the attenuation coefficient of a pressure wave in the tube decreased from 4.3 to 1.6 dB/m because of the tube stiffness (Young's modulus: 60 to 200 kPa). When the viscosity of liquid increased from approximately 4 to 10 mPa·s (the range of human blood viscosity) in the stiff tube, the attenuation coefficient of the pressure wave changed from 1.6 to 3.2 dB/m. The hardening of the blood vessel caused by aging and the increase of blood viscosity caused by illness possibly have opposite effects on the intravascular pressure wave. The effect of the viscosity of a liquid on the amplitude of a pressure wave was then considered using a phantom simulating human blood vessels. As a result, in the typical range of blood viscosity, the amplitude ratio of the waves obtained by the experiments with water and glycerin solution became 1:0.83. In comparison with clinical data, this value is much smaller than that seen from blood vessel hardening. Thus, it can be concluded that the blood viscosity seldom affects the attenuation of a pulse wave.

  13. An in vitro comparison of tracheostomy tube cuffs

    PubMed Central

    Maguire, Seamus; Haury, Frances; Jew, Korinne

    2015-01-01

    Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the cylindrical-shaped cuff, for each tube size tested (P<0.05). The insertion force for the taper-shaped cuff was ~40% less than that for the cylindrical-shaped cuff. Conclusion In a model trachea, the Shiley™ Flexible Adult tracheostomy tube with TaperGuard™ cuff, when compared to the Shiley™ Disposable Inner Cannula Tracheostomy tube with cylindrical cuff, exerted a lower average lateral wall pressure and a more evenly distributed pressure. In addition, it provided more effective fluid and air seals and required less force to insert. PMID:25960679

  14. The Effect of Compressibility on the Pressure Reading of a Prandtl Pitot Tube at Subsonic Flow Velocity

    NASA Technical Reports Server (NTRS)

    Walchner, O

    1939-01-01

    Errors arising from yawed flow were also determined up to 20 degrees angle of attack. In axial flow, the Prandtl pitot tube begins at w/a approx. = 0.8 to give an incorrect static pressure reading, while it records the tank pressure correctly, as anticipated, up to sonic velocity. Owing to the compressibility of the air, the Prandtl pitot tube manifests compression shocks when the air speed approaches velocity of sound. This affects the pressure reading of the instrument. Because of the increasing importance of high speed in aviation, this compressibility effect is investigated in detail.

  15. Comparisons of wing pressure distribution from flight tests of flush and external orifices for Mach numbers from 0.50 to 0.97

    NASA Technical Reports Server (NTRS)

    Montoya, L. C.; Lux, D. P.

    1975-01-01

    Wing pressure distributions obtained in flight with flush orifice and external tubing orifice installations for Mach numbers from 0.50 to 0.97 are compared. The procedure used to install the external tubing orifice is discussed. The results indicate that external tubing orifice installations can give useful results.

  16. Effects on Vocal Fold Collision and Phonation Threshold Pressure of Resonance Tube Phonation with Tube End in Water

    ERIC Educational Resources Information Center

    Enflo, Laura; Sundberg, Johan; Romedahl, Camilla; McAllister, Anita

    2013-01-01

    Purpose: Resonance tube phonation in water (RTPW) or in air is a voice therapy method successfully used for treatment of several voice pathologies. Its effect on the voice has not been thoroughly studied. This investigation analyzes the effects of RTPW on collision and phonation threshold pressures (CTP and PTP), the lowest subglottal pressure…

  17. A unifying model for elongational flow of polymer melts and solutions based on the interchain tube pressure concept

    NASA Astrophysics Data System (ADS)

    Wagner, Manfred Hermann; Rolón-Garrido, Víctor Hugo

    2015-04-01

    An extended interchain tube pressure model for polymer melts and concentrated solutions is presented, based on the idea that the pressures exerted by a polymer chain on the walls of an anisotropic confinement are anisotropic (M. Doi and S. F. Edwards, The Theory of Polymer Dynamics, Oxford University Press, New York, 1986). In a tube model with variable tube diameter, chain stretch and tube diameter reduction are related, and at deformation rates larger than the inverse Rouse time τR, the chain is stretched and its confining tube becomes increasingly anisotropic. Tube diameter reduction leads to an interchain pressure in the lateral direction of the tube, which is proportional to the 3rd power of stretch (G. Marrucci and G. Ianniruberto. Macromolecules 37, 3934-3942, 2004). In the extended interchain tube pressure (EIP) model, it is assumed that chain stretch is balanced by interchain tube pressure in the lateral direction, and by a spring force in the longitudinal direction of the tube, which is linear in stretch. The scaling relations established for the relaxation modulus of concentrated solutions of polystyrene in oligomeric styrene (M. H. Wagner, Rheol. Acta 53, 765-777, 2014, M. H. Wagner, J. Non-Newtonian Fluid Mech. http://dx.doi.org/10.1016/j.jnnfm.2014.09.017, 2014) are applied to the solutions of polystyrene (PS) in diethyl phthalate (DEP) investigated by Bhattacharjee et al. (P. K. Bhattacharjee et al., Macromolecules 35, 10131-10148, 2002) and Acharya et al. (M. V. Acharya et al. AIP Conference Proceedings 1027, 391-393, 2008). The scaling relies on the difference ΔTg between the glass-transition temperatures of the melt and the glass-transition temperatures of the solutions. ΔTg can be inferred from the reported zero-shear viscosities, and the BSW spectra of the solutions are obtained from the BSW spectrum of the reference melt with good accuracy. Predictions of the EIP model are compared to the steady-state elongational viscosity data of PS/DEP solutions. Except for a possible influence of solvent quality, linear and nonlinear viscoelasticity of entangled polystyrene solutions can thus be obtained from the linear-viscoelastic characteristics of a reference polymer melt and the shift of the glass transition temperature between melt and solution.

  18. High-temperature, high-pressure optical cell

    NASA Technical Reports Server (NTRS)

    Harris, R. P. (Inventor); Holland, L. R. (Inventor); Smith, R. E. (Inventor)

    1986-01-01

    The invention is an optical cell for containment of chemicals under conditions of high temperature and high pressure. The cell is formed of a vitreous silica tube, two optical windows comprising a vitreous silica rod inserted into the ends of a tube, and fused into position in the tube ends. Windows are spaced apart to form a cavity enclosed by the tube and the windows. A hole is drilled radially through the tube and into the cavity. Another vitreous silica tube is fused to the silica tube around the hole to form the stem, which is perpendicular to the long axis of the tube. The open end of the stem is used to load chemicals into the cavity. Then the stem may be sealed, and if desired, it may be shortened in order to reduce the volume of the cavity, which extends into the stem.

  19. Inspection system for a turbine blade region of a turbine engine

    DOEpatents

    Smed, Jan P [Winter Springs, FL; Lemieux, Dennis H [Casselberry, FL; Williams, James P [Orlando, FL

    2007-06-19

    An inspection system formed at least from a viewing tube for inspecting aspects of a turbine engine during operation of the turbine engine. An outer housing of the viewing tube may be positioned within a turbine engine using at least one bearing configured to fit into an indentation of a support housing to form a ball and socket joint enabling the viewing tube to move during operation as a result of vibrations and other movements. The viewing tube may also include one or more lenses positioned within the viewing tube for viewing the turbine components. The lenses may be kept free of contamination by maintaining a higher pressure in the viewing tube than a pressure outside of the viewing tube and enabling gases to pass through an aperture in a cap at a viewing end of the viewing tube.

  20. A novel method for calculating the dynamic capillary force and correcting the pressure error in micro-tube experiment.

    PubMed

    Wang, Shuoliang; Liu, Pengcheng; Zhao, Hui; Zhang, Yuan

    2017-11-29

    Micro-tube experiment has been implemented to understand the mechanisms of governing microcosmic fluid percolation and is extensively used in both fields of micro electromechanical engineering and petroleum engineering. The measured pressure difference across the microtube is not equal to the actual pressure difference across the microtube. Taking into account the additional pressure losses between the outlet of the micro tube and the outlet of the entire setup, we propose a new method for predicting the dynamic capillary pressure using the Level-set method. We first demonstrate it is a reliable method for describing microscopic flow by comparing the micro-model flow-test results against the predicted results using the Level-set method. In the proposed approach, Level-set method is applied to predict the pressure distribution along the microtube when the fluids flow along the microtube at a given flow rate; the microtube used in the calculation has the same size as the one used in the experiment. From the simulation results, the pressure difference across a curved interface (i.e., dynamic capillary pressure) can be directly obtained. We also show that dynamic capillary force should be properly evaluated in the micro-tube experiment in order to obtain the actual pressure difference across the microtube.

  1. Pulsed electron beam propagation in gases under pressure of 6.6 kPa in drift tube

    NASA Astrophysics Data System (ADS)

    Kholodnaya, G. E.; Sazonov, R. V.; Ponomarev, D. V.; Remnev, G. E.; Poloskov, A. V.

    2017-02-01

    This paper presents the results of an investigation of pulsed electron beam transport propagated in a drift tube filled with different gases (He, H2, N2, Ar, SF6, and CO2). The total pressure in the drift tube was 6.6 kPa. The experiments were carried out using a TEA-500 pulsed electron accelerator. The electron beam was propagated in the drift tube composed of two sections equipped with reverse current shunts. Under a pressure of 6.6 kPa, the maximum value of the electron beam charge closed on the walls of the drift tube was recorded when the beam was propagated in hydrogen and carbon dioxide. The minimum value of the electron beam charge closed on the walls of the drift tube was recorded for sulfur hexafluoride. The visualization of the pulsed electron beam energy losses onto the walls of the drift chamber was carried out using radiation-sensitive film.

  2. Vortex rope instabilities in a model of conical draft tube

    NASA Astrophysics Data System (ADS)

    Skripkin, Sergey; Tsoy, Mikhail; Kuibin, Pavel; Shtork, Sergey

    2017-10-01

    We report on experimental studies of the formation of vortex ropes in a laboratory simplified model of hydroturbine draft tube. Work is focused on the observation of various flow patterns at the different rotational speed of turbine runner at fixed flow rate. The measurements involve high-speed visualization and pressure pulsations recordings. Draft tube wall pressure pulsations are registered by pressure transducer for different flow regimes. Vortex rope precession frequency were calculated using FFT transform. The experiments showed interesting features of precessing vortex rope like twin spiral and formation of vortex ring.

  3. Pressure and volume changes of tracheal tube cuff following inflation with various inflating agents during nitrous oxide anesthesia.

    PubMed

    Bajaj, Pramila; Nanda, Rajan; Goyal, Pradeep KR

    2004-10-01

    The study was designed to investigate the changes in pressure and volume of a tracheal tube-cuff inflated with air, mixture of N2O + O2, saline and 4% lidocaine during nitrous oxide anesthesia. This study was conducted in 80 patients (33 male & 47 female). The pressure and volume of a tracheal tube cuff increased with air, decreased with mixture of N2O + O2 and almost remained the same with saline and 4% lidocaine. The complications were more in the air group.

  4. Horizontal Advanced Tensiometer

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2004-06-22

    An horizontal advanced tensiometer is described that allows the monitoring of the water pressure of soil positions, particularly beneath objects or materials that inhibit the use of previous monitoring wells. The tensiometer includes a porous cup, a pressure transducer (with an attached gasket device), an adaptive chamber, at least one outer guide tube which allows access to the desired horizontal position, a transducer wire, a data logger and preferably an inner guide tube and a specialized joint which provides pressure on the inner guide tube to maintain the seal between the gasket of the transducer and the adaptive chamber.

  5. Managing endotracheal tube cuff pressure at altitude: a comparison of four methods.

    PubMed

    Britton, Tyler; Blakeman, Thomas C; Eggert, John; Rodriquez, Dario; Ortiz, Heather; Branson, Richard D

    2014-09-01

    Ascent to altitude results in the expansion of gases in closed spaces. The management of overinflation of the endotracheal tube (ETT) cuff at altitude is critical to prevent mucosal injury. We continuously measured ETT cuff pressures during a Critical Care Air Transport Team training flight to 8,000-ft cabin pressure using four methods of cuff pressure management. ETTs were placed in a tracheal model, and mechanical ventilation was performed. In the control ETT, the cuff was inflated to 20 mm Hg to 22 mm Hg and not manipulated. The manual method used a pressure manometer to adjust pressure at cruising altitude and after landing. A PressureEasy device was connected to the pilot balloon of the third tube and set to a pressure of 20 mm Hg to 22 mm Hg. The final method filled the balloon with 10 mL of saline. Both size 8.0-mm and 7.5-mm ETT were studied during three flights. In the control tube, pressure exceeded 70 mm Hg at cruising altitude. Manual management corrected for pressure at altitude but resulted in low cuff pressures upon landing (<10 mm Hg). The PressureEasy reduced the pressure change to a maximum of 36 mm Hg, but on landing, cuff pressures were less than 15 mm Hg. Saline inflation ameliorated cuff pressure changes at altitude, but initial pressures were 40 mm Hg. None of the three methods using air inflation managed to maintain cuff pressures below those associated with tracheal damage at altitude or above pressures associated with secretion aspiration during descent. Saline inflation minimizes altitude-related alteration in cuff pressure but creates excessive pressures at sea level. New techniques need to be developed.

  6. High Performance Ion Mobility Spectrometry Using Hourglass Electrodynamic Funnel And Internal Ion Funnel

    DOEpatents

    Smith, Richard D.; Tang, Keqi; Shvartsburg, Alexandre A.

    2005-11-22

    A method and apparatus enabling increased sensitivity in ion mobility spectrometry/mass spectrometry instruments which substantially reduces or eliminates the loss of ions in ion mobility spectrometer drift tubes utilizing a device for transmitting ions from an ion source which allows the transmission of ions without significant delay to an hourglass electrodynamic ion funnel at the entrance to the drift tube and/or an internal ion funnel at the exit of the drift tube. An hourglass electrodynamic funnel is formed of at least an entry element, a center element, and an exit element, wherein the aperture of the center element is smaller than the aperture of the entry element and the aperture of the exit elements. Ions generated in a relatively high pressure region by an ion source at the exterior of the hourglass electrodynamic funnel are transmitted to a relatively low pressure region at the entrance of the hourglass funnel through a conductance limiting orifice. Alternating and direct electrical potentials are applied to the elements of the hourglass electrodynamic funnel thereby drawing ions into and through the hourglass electrodynamic funnel thereby introducing relatively large quantities of ions into the drift tube while maintaining the gas pressure and composition at the interior of the drift tube as distinct from those at the entrance of the electrodynamic funnel and allowing a positive gas pressure to be maintained within the drift tube, if desired. An internal ion funnel is provided within the drift tube and is positioned at the exit of said drift tube. The advantage of the internal ion funnel is that ions that are dispersed away from the exit aperture within the drift tube, such as those that are typically lost in conventional drift tubes to any subsequent analysis or measurement, are instead directed through the exit of the drift tube, vastly increasing the amount of ions exiting the drift tube.

  7. Prevention

    MedlinePlus

    ... Heart Disease Stroke High Blood Pressure Cholesterol Salt Video: Gail’s Story YouTube embed video: YouTube embed video: https://www.youtube-nocookie.com/embed/ZOoRLFdOdac Video: Aaron’s Story YouTube embed video: YouTube embed video: ...

  8. A dynamic pressure source for the calibration of pressure transducers

    NASA Technical Reports Server (NTRS)

    Vezzetti, C. F.; Hilten, J. S.; Mayo-Wells, J. F.; Lederer, P. S.

    1976-01-01

    A dynamic pressure source is described for producing sinusoidally varying pressures of up to 34 kPa zero to peak, over the frequency range of approximately 50 Hz to 2 kHz. The source is intended for the dynamic calibration of pressure transducers. The transducer to be calibrated is mounted near the base of the thick walled aluminum tube forming the vessel so that the pressure sensitive element is in contact with the liquid in the tube. A section of the tube is filled with small steel balls to damp the motion of the 10-St dimethyl siloxane working fluid in order to extend the useful frquency range to higher frequencies than would be provided by an undamped system. The dynamic response of six transducers provided by the sponsor was evaluated using the pressure sources; the results of these calibrations are given.

  9. Reduction of frequent otitis media and pressure-equalizing tube insertions in children after introduction of pneumococcal conjugate vaccine.

    PubMed

    Poehling, Katherine A; Szilagyi, Peter G; Grijalva, Carlos G; Martin, Stacey W; LaFleur, Bonnie; Mitchel, Ed; Barth, Richard D; Nuorti, J Pekka; Griffin, Marie R

    2007-04-01

    Streptococcus pneumoniae is an important cause of otitis media in children. In this study we estimated the effect of routine childhood immunization with heptavalent pneumococcal conjugate vaccine on frequent otitis media (3 episodes in 6 months or 4 episodes in 1 year) and pressure-equalizing tube insertions. The study population included all children who were enrolled at birth in TennCare or selected upstate New York commercial insurance plans as of July 1998 and continuously followed until 5 years old, loss of health plan enrollment, study outcome, or end of the study. We compared the risk of developing frequent otitis media or having pressure-equalizing tube insertion for 4 birth cohorts (1998-1999, 1999-2000, 2000-2001, and 2001-2002) by using Cox regression analysis. We used data from the National Immunization Survey to estimate the heptavalent pneumococcal conjugate vaccine uptake for children in these 4 birth cohorts in Tennessee and New York. The proportion of children in Tennessee and New York who received at least 3 doses of heptavalent pneumococcal conjugate vaccine by 2 years of age increased from < or = 1% for the 1998-1999 birth cohort to approximately 75% for the 2000-2001 birth cohort. By age 2 years, 29% of Tennessee and New York children born in 2000-2001 had developed frequent otitis media, and 6% of each of these birth cohorts had pressure-equalizing tubes inserted. Comparing the 2000-2001 birth cohort to the 1998-1999 birth cohort, frequent otitis media declined by 17% and 28%, and pressure-equalizing tube insertions declined by 16% and 23% for Tennessee and New York children, respectively. For the 2000-2001 to the 2001-2002 birth cohort, frequent otitis media and pressure-equalizing tubes remained stable in New York but increased in Tennessee. After heptavalent pneumococcal conjugate vaccine introduction, children were less likely to develop frequent otitis media or have pressure-equalizing tube insertions.

  10. Propagation of atmospheric-pressure ionization waves along the tapered tube

    NASA Astrophysics Data System (ADS)

    Xia, Yang; Wang, Wenchun; Liu, Dongping; Yan, Wen; Bi, Zhenhua; Ji, Longfei; Niu, Jinhai; Zhao, Yao

    2018-02-01

    Gas discharge in a small radius dielectric tube may result in atmospheric pressure plasma jets with high energy and density of electrons. In this study, the atmospheric pressure ionization waves (IWs) were generated inside a tapered tube. The propagation behaviors of IWs inside the tube were studied by using a spatially and temporally resolved optical detection system. Our measurements show that both the intensity and velocity of the IWs decrease dramatically when they propagate to the tapered region. After the taper, the velocity, intensity, and electron density of the IWs are improved with the tube inner diameter decreasing from 4.0 to 0.5 mm. Our analysis indicates that the local gas conductivity and surface charges may play a role in the propagation of the IWs under such a geometrical constraint, and the difference in the dynamics of the IWs after the taper can be related to the restriction in the size of IWs.

  11. On random pressure pulses in the turbine draft tube

    NASA Astrophysics Data System (ADS)

    Kuibin, P. A.; Shtork, S. I.; Skripkin, S. G.; Tsoy, M. A.

    2017-04-01

    The flow in the conical part of the hydroturbine draft tube undergoes various instabilities due to deceleration and flow swirling at off-design operation points. In particular, the precessing vortex rope develops at part-load regimes in the draft tube. This rope induces periodical low-frequency pressure oscillations in the draft tube. Interaction of rotational (asynchronous) mode of disturbances with the elbow can bring to strong oscillations in the whole hydrodynamical system. Recent researches on flow structure in the discharge cone in a regime of free runner had revealed that helical-like vortex rope can be unstable itself. Some coils of helix close to each other and reconnection appears with generation of a vortex ring. The vortex ring moves toward the draft tube wall and downstream. The present research is focused on interaction of vortex ring with wall and generation of pressure pulses.

  12. Analysis and testing of high entrainment single nozzle jet pumps with variable mixing tubes

    NASA Technical Reports Server (NTRS)

    Hickman, K. E.; Hill, P. G.; Gilbert, G. B.

    1972-01-01

    An analytical model was developed to predict the performance characteristics of axisymmetric single-nozzle jet pumps with variable area mixing tubes. The primary flow may be subsonic or supersonic. The computer program uses integral techniques to calculate the velocity profiles and the wall static pressures that result from the mixing of the supersonic primary jet and the subsonic secondary flow. An experimental program was conducted to measure mixing tube wall static pressure variations, velocity profiles, and temperature profiles in a variable area mixing tube with a supersonic primary jet. Static pressure variations were measured at four different secondary flow rates. These test results were used to evaluate the analytical model. The analytical results compared well to the experimental data. Therefore, the analysis is believed to be ready for use to relate jet pump performance characteristics to mixing tube design.

  13. Cold cathode vacuum gauging system

    DOEpatents

    Denny, Edward C.

    2004-03-09

    A vacuum gauging system of the cold cathode type is provided for measuring the pressure of a plurality of separate vacuum systems, such as in a gas centrifuge cascade. Each casing is fitted with a gauge tube assembly which communicates with the vacuum system in the centrifuge casing. Each gauge tube contains an anode which may be in the form of a slender rod or wire hoop and a cathode which may be formed by the wall of the gauge tube. The tube is provided with an insulated high voltage connector to the anode which has a terminal for external connection outside the vacuum casing. The tube extends from the casing so that a portable magnet assembly may be inserted about the tube to provide a magnetic field in the area between the anode and cathode necessary for pressure measurements in a cold cathode-type vacuum gauge arrangement. The portable magnetic assembly is provided with a connector which engages the external high voltage terminal for providing power to the anode within in the gauge tube. Measurement is made in the same manner as the prior cold cathode gauges in that the current through the anode to the cathode is measured as an indication of the pressure. By providing the portable magnetic assembly, a considerable savings in cost, installation, and maintenance of vacuum gauges for pressure measurement in a gas centrifuge cascade is realizable.

  14. COTS MEMS Flow-Measurement Probes

    NASA Technical Reports Server (NTRS)

    Redding, Chip; Smith, Floyd A.; Blank, Greg; Cruzan, Charles

    2004-01-01

    As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at Glenn Research Center have been fabricating packaging components and assembling a set of unique probes that contain commercial off-the-shelf (COTS) microelectromechanical systems (MEMS) sensor chips. MEMS sensor chips offer some compelling advantages over standard macroscopic measurement devices. MEMS sensor technology has matured through mass production and use in the automotive and aircraft industries. At present, MEMS are the devices of choice for sensors in such applications as tire-pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Compactness, minimality of power demand, rugged construction, and moderate cost all contribute to making MEMS sensors attractive for instrumentation for future research. Conventional macroscopic flow-measurement instrumentation includes tubes buried beneath the aerodynamic surfaces of wind-tunnel models or in wind-tunnel walls. Pressure is introduced at the opening of each such tube. The pressure must then travel along the tube before reaching a transducer that generates an electronic signal. The lengths of such tubes typically range from 20 ft (approx.= 6 m) to hundreds of feet (of the order of 100 m). The propagation of pressure signals in the tubes damps the signals considerably and makes it necessary to delay measurements until after test rigs have reached steady-state operation. In contrast, a MEMS pressure sensor that generates electronic output can take readings continuously under dynamic conditions in nearly real time. In order to use stainless-steel tubing for pressure measurements, it is necessary to clean many tubes, cut them to length, carefully install them, delicately deburr them, and splice them. A cluster of a few hundred 1/16-in.- (approx.=1.6-mm-) diameter tubes (such clusters are common in research testing facilities) can be several inches (of the order of 10 cm) in diameter and could weigh enough that two technicians are needed to handle it. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of a 1/16-in. tube with room to spare. The Lucas NovaSensor P592 piezoresistive silicon pressure sensor was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The sensor chip is 1 mm square by 0.6 mm thick (about 0.039 by 0.039 by 0.024 in.) and includes 0.12-mm (approx.=0.005-in.) wire connection tabs. The figure shows a flow-angularity probe that was built by use of three such MEMS chips. It is planned to demonstrate this MEMS probe as an alternative to a standard tube-type "Cobra" probe now used routinely in wind tunnels and aeronautical hardware. This MEMS probe could be translated across a flow field by use of a suitable actuator, so that its accuracy and the shortness of its response time could be exploited to obtain precise dynamic measurements of a sort that cannot be made by use of conventional tubing-based instrumentation.

  15. Dynamic Runner Forces and Pressure Fluctuations on the Draft Tube Wall of a Model Pump-Turbine

    NASA Astrophysics Data System (ADS)

    Kirschner, O.; Ruprecht, A.; Göde, E.; Riedelbauch, S.

    2016-11-01

    When Francis-turbines and pump-turbines operate at off-design conditions, typically a vortex rope develops. The vortex rope causes pressure oscillations leading to fluctuations of the forces affecting the runner. The presence of dynamic runner forces over a long period of time might damage the bearings and possibly the runner. In this experimental investigation, the fluctuating part of the runner forces and the pressure oscillations on the draft tube wall were measured on a model pump-turbine with a simplified straight cone draft tube in different operating conditions. The investigation focuses on the correlation of the pressure fluctuations frequency measured at the draft tube wall with the frequency of the fluctuating forces on the runner. The comparison between pressure fluctuations and dynamic forces shows a significant correlation in all operating points. For the comparison of different components in the spatial directions of the forces, the pressure fluctuations were separated in a synchronous part and a rotating part for operating points with higher amplitudes. The rotating pressure fluctuations correlate with the radial forces especially in the operating points with a rotating vortex rope. At frequencies with higher amplitudes in the pressure fluctuations caused by the vortex rope movement, there are also higher amplitudes in the radial forces at the same frequencies.

  16. Enhancing the aggressive intensity of hydrodynamic cavitation through a Venturi tube by increasing the pressure in the region where the bubbles collapse

    NASA Astrophysics Data System (ADS)

    Soyama, H.; Hoshino, J.

    2016-04-01

    In this paper, we used a Venturi tube for generating hydrodynamic cavitation, and in order to obtain the optimum conditions for this to be used in chemical processes, the relationship between the aggressive intensity of the cavitation and the downstream pressure where the cavitation bubbles collapse was investigated. The acoustic power and the luminescence induced by the bubbles collapsing were investigated under various cavitating conditions, and the relationships between these and the cavitation number, which depends on the upstream pressure, the downstream pressure at the throat of the tube and the vapor pressure of the test water, was found. It was shown that the optimum downstream pressure, i.e., the pressure in the region where the bubbles collapse, increased the aggressive intensity by a factor of about 100 compared to atmospheric pressure without the need to increase the input power. Although the optimum downstream pressure varied with the upstream pressure, the cavitation number giving the optimum conditions was constant for all upstream pressures.

  17. Optical fiber pressure and acceleration sensor fabricated on a fiber endface

    DOEpatents

    Zhu, Yizheng; Wang, Xingwei; Xu, Juncheng; Wang, Anbo

    2006-05-30

    A fiber optic sensor has a hollow tube bonded to the endface of an optical fiber, and a diaphragm bonded to the hollow tube. The fiber endface and diaphragm comprise an etalon cavity. The length of the etalon cavity changes when applied pressure or acceleration flexes the diaphragm. The entire structure can be made of fused silica. The fiber, tube, and diaphragm can be bonded with a fusion splice. The present sensor is particularly well suited for measuring pressure or acceleration in high temperature, high pressure and corrosive environments (e.g., oil well downholes and jet engines). The present sensors are also suitable for use in biological and medical applications.

  18. Computer-Aided Thermohydraulic Design of TEMA Type E Shell and Tube Heat Exchangers for Use in Low Pressure, Liquid-to-Liquid, Single Phase Applications.

    DTIC Science & Technology

    1985-04-01

    and Standards .. ... ....... ....... 9 A. General . ... .. .. ... ..... .. .. ... 9 B. ASME Boiler and Pressure Vessel Code .. .. ......9 C. Foreign...several different sources. B. American Society of Mechanial Engineers (ASME) Boiler and Pressure Vessel Code A shell and tube heat exchanger is indeed a

  19. Visualization and flow boiling heat transfer of hydrocarbons in a horizontal tube

    NASA Astrophysics Data System (ADS)

    Yang, Zhuqiang; Bi, Qincheng; Guo, Yong; Liu, Zhaohui; Yan, Jianguo

    2013-07-01

    Visualizations of a specific hydrocarbon fuel in a horizontal tube with 2.0 mm inside diameter were investigated. The experiments were conducted at mass velocity of 213.4, 426.5 and 640.2 kg/ (m2ṡs), diabatic lengths of 140, 240 and 420 mm under the pressure from 2.0-2.7 MPa. In the sub-pressure conditions, bubbly, intermittent, stratified-wave, churn and annular flow patterns were observed. The frictional pressure drops were also measured to distinguish the patterns. The development of flow patterns and frictional pressure drop were positively related to the mass velocity and the heat flux. However, the diabatic length of the tube takes an important part in the process. The residence time of the fluid does not only affect the transition of the patterns but influence the composition of the fuel manifested by the fuel color and carbon deposit. The special observational phenomenon was obtained for the supercritical pressure fluid. The flow in the tube became fuzzier and pressure drop changed sharply near the pseudocritical point. The flow boiling heat transfer characteristics of the hydrocarbons were also discussed respectively. The curve of critical heat flux about onset of nucleate boiling was plotted with different mass velocities and diabatic tube lengths. And heat transfer characteristics of supercritical fuel were proved to be better than that in subcritical conditions.

  20. Investigation of two pitot-static tubes at supersonic speeds

    NASA Technical Reports Server (NTRS)

    Hasel, Lowell E; Coletti, Donald E

    1948-01-01

    The results of tests at a Mach number of 1.94 of an ogives-nose cylindrical pitot-static tube and similar tests at Mach numbers of 1.93 and 1.62 of a service pitot-static tube to determine body static pressures and indicated Mach numbers are presented and discussed. The radial pressure distribution on the cylindrical bodies is compared with that calculated by an approximate theory.

  1. Creep-rupture tests of internally pressurized Inconel 702 tubes

    NASA Technical Reports Server (NTRS)

    Gumto, K. H.

    1973-01-01

    Seamless Inconel 702 tubes with 0.375-in. outside diameter and 0.025-in. wall thickness were tested to failure at temperatures from 1390 to 1575 F and internal helium pressures from 700 to 1800 psi. Lifetimes ranged from 29 to 1561 hr. The creep-rupture strength of the tubes was about 70 percent lower than that of sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.

  2. Superhydrophobic copper tubes with possible flow enhancement and drag reduction.

    PubMed

    Shirtcliffe, Neil J; McHale, Glen; Newton, Michael I; Zhang, Yong

    2009-06-01

    The transport of a Newtonian liquid through a smooth pipe or tube is dominated by the frictional drag on the liquid against the walls. The resistance to flow against a solid can, however, be reduced by introducing a layer of gas at or near the boundary between the solid and liquid. This can occur by the vaporization of liquid at a surface at a temperature above the Leidenfrost point, by a cushion of air (e.g. below a hovercraft), or by producing bubbles at the interface. These methods require a continuous energy input, but a more recent discovery is the possibility of using a superhydrophobic surface. Most reported research uses small sections of lithographically patterned surfaces and rarely considers pressure differences or varying flow rates. In this work we present a method for creating a uniform superhydrophobic nanoribbon layer on the inside of round copper tubes of millimetric internal radius. Two types of experiments are described, with the first involving a simultaneous comparison of four tubes with different surface finishes (as received, as received with hydrophobic coating, nanoribbon, and nanoribbon with a hydrophobic coating) under constant flow rate conditions using water and water-glycerol mixtures. The results show that the superhydrophobic nanoribbon with a hydrophobic coating surface finish allows greater flow at low pressure differences but that the effect disappears as the pressure at the inlet of the tube is increased. The second experiment is a simple visual demonstration of the low-pressure behavior using two nominally identical tubes in terms of length and cross-section, but with one tube possessing a superhydrophobic internal surface finish. In this experiment a reservoir is allowed to feed the two tubes with open ends via a T-piece and it is observed that, once flow commences, it preferentially occurs down the superhydrophobic tube.

  3. Oxy-acetylene driven laboratory scale shock tubes for studying blast wave effects

    NASA Astrophysics Data System (ADS)

    Courtney, Amy C.; Andrusiv, Lubov P.; Courtney, Michael W.

    2012-04-01

    This paper describes the development and characterization of modular, oxy-acetylene driven laboratory scale shock tubes. Such tools are needed to produce realistic blast waves in a laboratory setting. The pressure-time profiles measured at 1 MHz using high-speed piezoelectric pressure sensors have relevant durations and show a true shock front and exponential decay characteristic of free-field blast waves. Descriptions are included for shock tube diameters of 27-79 mm. A range of peak pressures from 204 kPa to 1187 kPa (with 0.5-5.6% standard error of the mean) were produced by selection of the driver section diameter and distance from the shock tube opening. The peak pressures varied predictably with distance from the shock tube opening while maintaining both a true blast wave profile and relevant pulse duration for distances up to about one diameter from the shock tube opening. This shock tube design provides a more realistic blast profile than current compression-driven shock tubes, and it does not have a large jet effect. In addition, operation does not require specialized personnel or facilities like most blast-driven shock tubes, which reduces operating costs and effort and permits greater throughput and accessibility. It is expected to be useful in assessing the response of various sensors to shock wave loading; assessing the reflection, transmission, and absorption properties of candidate armor materials; assessing material properties at high rates of loading; assessing the response of biological materials to shock wave exposure; and providing a means to validate numerical models of the interaction of shock waves with structures. All of these activities have been difficult to pursue in a laboratory setting due in part to lack of appropriate means to produce a realistic blast loading profile.

  4. The transfer of atmospheric-pressure ionization waves via a metal wire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Yang; Liu, Dongping, E-mail: Dongping.liu@dlnu.edu.cn; School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024

    2016-01-15

    Our study has shown that the atmospheric-pressure He ionization waves (IWs) may be transferred from one dielectric tube (tube 1) to the other one (tube 2) via a floating metal wire. The propagation of IWs along the two tubes is not affected by the diameter of a floating metal wire, however, their propagation is strongly dependent on the length of a floating metal wire. The propagation of one IW along the tube 1 may result in the second IW propagating reversely inside the tube in vicinity of a floating metal wire, which keeps from their further propagation through the tubemore » 1. After they merge together as one conduction channel inside the tube 1, the transferred plasma bullet starts to propagate along the tube 2. The propagation of transferred plasma bullets along the tube 2 is mainly determined by the capacitance and inductance effects, and their velocity and density can be controlled by the length of a floating metal wire.« less

  5. In situ microscopy reveals reversible cell wall swelling in kelp sieve tubes: one mechanism for turgor generation and flow control?

    PubMed

    Knoblauch, Jan; Tepler Drobnitch, Sarah; Peters, Winfried S; Knoblauch, Michael

    2016-08-01

    Kelps, brown algae (Phaeophyceae) of the order Laminariales, possess sieve tubes for the symplasmic long-distance transport of photoassimilates that are evolutionarily unrelated but structurally similar to the tubes in the phloem of vascular plants. We visualized sieve tube structure and wound responses in fully functional, intact Bull Kelp (Nereocystis luetkeana [K. Mertens] Postels & Ruprecht 1840). In injured tubes, apparent slime plugs formed but were unlikely to cause sieve tube occlusion as they assembled at the downstream side of sieve plates. Cell walls expanded massively in the radial direction, reducing the volume of the wounded sieve elements by up to 90%. Ultrastructural examination showed that a layer of the immediate cell wall characterized by circumferential cellulose fibrils was responsible for swelling and suggested that alginates, abundant gelatinous polymers of the cell wall matrix, were involved. Wall swelling was rapid, reversible and depended on intracellular pressure, as demonstrated by pressure-injection of silicon oil. Our results revive the concept of turgor generation and buffering by swelling cell walls, which had fallen into oblivion over the last century. Because sieve tube transport is pressure-driven and controlled physically by tube diameter, a regulatory role of wall swelling in photoassimilate distribution is implied in kelps. © 2016 John Wiley & Sons Ltd.

  6. Echocardiographic evaluation during weaning from mechanical ventilation.

    PubMed

    Schifelbain, Luciele Medianeira; Vieira, Silvia Regina Rios; Brauner, Janete Salles; Pacheco, Deise Mota; Naujorks, Alexandre Antonio

    2011-01-01

    Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T-tube; and comparing patient subgroups: success vs. failure in weaning. Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T-tube. Pressure support ventilation vs. T-tube and weaning success vs. failure were compared using ANOVA and Student's t-test. The level of significance was p<0.05. Twenty-four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T-tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T-tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients.

  7. [Application research of presacral space drainage tube combined with subcutaneous vacuum pressure suction in the laparoscopic-assisted abdominoperineal resection].

    PubMed

    Chen, Liqi; Zeng, Changqing; Chi, Liangjie; Huang, Liangxiang; Li, Jiandang

    2017-08-25

    To study the management for the perineal incision after laparoscopic-assisted abdominoperineal resection for rectal cancer. Clinical data of 87 patients undergoing laparoscopic Miles operation for lower rectal cancer from June 2009 to February 2014 were collected and studied. Presacral space drainage group: presacral space drainage tube was applied in 42 patients. Combined drainage group: presacral space drainage tube combined with subcutaneous vacuum pressure suction was applied in 45 cases. In combined drainage group, except the presacral drainage tube, another drainage tube was placed subcutaneously and connected to a negative pressure ball, which was fixed on the lateral anterior of perineal wound by the further incision and drainage. After subcutaneous tube was placed for 2 weeks, as drainage fluid was limpid and <15 ml/d for 3 days, meanwhile no obvious pelvic fluid was detected by ultrasound, and the wound healed quite well without redness and edema, then the subcutaneous tube with the negative pressure ball could be removed. There were 51 males and 36 females with the mean age of 26-78(56.9±10.8) years old. The laparoscopic Miles operation was successfully completed in all the cases without death and complications. The drainage tube was placed for 4-13(8.0±2.5) days in presacral space drainage group, and for 4-14(6.7±2.4) days in combined drainage group. The subcutaneous tube was placed for 14-24(15.8±3.0) days. The primary healing rate of perineal wound in presacral space drainage group and combined drainage group was 66.7%(28/42) and 91.1%(41/45) respectively, while the perineal wound infection rate was 21.4%(9/42) and 4.4%(2/45) respectively, whose differences between two groups were both significant (χ 2 =7.911, P=0.005 and χ 2 =5.674, P=0.017). Presacral space drainage tube combined with subcutaneous vacuum pressure suction in laparoscopic-assisted abdominoperineal resection for rectal cancer has better efficacy and lower infection rate for perineal incision, which is worth wide application.

  8. Nonlinear ballooning modes in tokamaks: stability and saturation

    NASA Astrophysics Data System (ADS)

    Ham, C. J.; Cowley, S. C.; Brochard, G.; Wilson, H. R.

    2018-07-01

    The nonlinear dynamics of magneto-hydrodynamic ballooning mode perturbations is conjectured to be characterised by the motion of isolated elliptical flux tubes. The theory of stability, dynamics and saturation of such tubes in tokamaks is developed using a generalised Archimedes’ principle. The equation of motion for a tube moving against a drag force in a general axisymmetric equilibrium is derived and then applied to a simplified ‘s–α’ equilibrium. The perturbed nonlinear tube equilibrium (saturated) states are investigated in an ‘s–α’ equilibrium with specific pressure and magnetic shear profiles. The energy of these nonlinear (ballooning) saturated states is calculated. In some cases, particularly at low magnetic shear, these finitely displaced states can have a lower energy than the equilibrium state even if the profile is linearly stable to ballooning modes (infinitesimal tube displacements) at all radii. Thus nonlinear ballooning modes can be metastable. The amplitude of the saturated tube displacement in such cases can be as large as the pressure gradient scale length. We conjecture that triggering a transition into these filamentary states can lead to hard instability limits. A short survey of different pressure profiles is presented to illustrate the variety of behaviour of perturbed elliptical flux tubes.

  9. Vortex formation at the open end of an acoustic waveguide

    NASA Astrophysics Data System (ADS)

    Martinez Del Rio, Leon; Rendon, Pablo L.; Malaga, Carlos; Zenit, Roberto

    2017-11-01

    For high enough levels of acoustic pressure inside a cylindrical tube, a nonlinear mechanism is responsible for the formation of annular vortices at the open end of the tube, which results in energy loss. Higher sound pressure levels in the tube lead, in turn, to larger values of the acoustic velocity at the exit, and thus to higher Reynolds numbers. It has been observed [Buick et al., 2011] that, provided the magnitude of the acoustic velocity is large enough, two nonlinear regimes are possible: in the first regime, the vorticity appears only in the immediate vicinity of the tube; for higher velocities, vortex rings are formed at the open end of the tube and are advected outwards. We use a Lattice Boltzmann Method (LBM) to simulate the velocity and the pressure fields at the exit of the tube in 3D, with Reynolds numbers based on the acoustic boundary layer thickness 18 >Rδ > 1.8 . We also conduct experiments with phase-locked particle image velocimetry (PL-PIV) 2D within a range of 25.5 >Rδ > 10.2 . Experimental and numerical results are compared for a range of Womersley numbers. The effects of varying both the tube geometry and the end shape are addressed.

  10. Characterization of size-dependent mechanical properties of tip-growing cells using a lab-on-chip device.

    PubMed

    Hu, Chengzhi; Munglani, Gautam; Vogler, Hannes; Ndinyanka Fabrice, Tohnyui; Shamsudhin, Naveen; Wittel, Falk K; Ringli, Christoph; Grossniklaus, Ueli; Herrmann, Hans J; Nelson, Bradley J

    2016-12-20

    Quantification of mechanical properties of tissues, living cells, and cellular components is crucial for the modeling of plant developmental processes such as mechanotransduction. Pollen tubes are tip-growing cells that provide an ideal system to study the mechanical properties at the single cell level. In this article, a lab-on-a-chip (LOC) device is developed to quantitatively measure the biomechanical properties of lily (Lilium longiflorum) pollen tubes. A single pollen tube is fixed inside the microfluidic chip at a specific orientation and subjected to compression by a soft membrane. By comparing the deformation of the pollen tube at a given external load (compressibility) and the effect of turgor pressure on the tube diameter (stretch ratio) with finite element modeling, its mechanical properties are determined. The turgor pressure and wall stiffness of the pollen tubes are found to decrease considerably with increasing initial diameter of the pollen tubes. This observation supports the hypothesis that tip-growth is regulated by a delicate balance between turgor pressure and wall stiffness. The LOC device is modular and adaptable to a variety of cells that exhibit tip-growth, allowing for the straightforward measurement of mechanical properties.

  11. High spatial resolution measurements in a single stage ram accelerator

    NASA Technical Reports Server (NTRS)

    Hinkey, J. B.; Burnham, E. A.; Bruckner, A. P.

    1992-01-01

    High spatial resolution experimental tube wall pressure measurements of ram accelerator gas dynamic phenomena are presented in this paper. The ram accelerator is a ramjet-in-tube device which operates in a manner similar to that of a conventional ramjet. The projectile resembles the centerbody of a ramjet and travels supersonically through a tube filled with a combustible gaseous mixture, with the tube acting as the outer cowling. Pressure data are recorded as the projectile passes by sensors mounted in the tube wall at various locations along the tube. Utilization of special highly instrumented sections of tube has allowed the recording of gas dynamic phenomena with high resolution. High spatial resolution tube wall pressure data from the three regimes of propulsion studied to date (subdetonative, transdetonative, and superdetonative) in a single stage gas mixture are presented and reveal the three-dimensional character of the flow field induced by projectile fins and the canting of the fins and the canting of the projectile body relative to the tube wall. Also presented for comparison to the experimental data are calculations made with an inviscid, three-dimensional CFD code. The knowledge gained from these experiments and simulations is useful in understanding the underlying nature of ram accelerator propulsive regimes, as well as assisting in the validation of three-dimensional CFD coded which model unsteady, chemically reactive flows.

  12. Identification of a Very High Cuff Pressure by Manual Palpation of the External Cuff Balloon on an Endotracheal Tube.

    PubMed

    Hedberg, Pia; Eklund, Carolina; Högqvist, Sandra

    2015-06-01

    The most common complication due to intubation is a high cuff pressure. A high cuff pressure can cause postanesthetic tracheal mucosal injuries in patients undergoing surgery. The aim of this cross-sectional study was to describe whether anesthetic nurses and anesthesiologists identified a very high cuff pressure by manual palpation of the external cuff balloon on an endotracheal tube. An airway device was intubated with an endotracheal tube cuffed to 95 cm H2O. Each participant palpated the external cuff balloon and then filled out a questionnaire, including estimation of the cuff pressure and user frequency of the cuff pressure manometer. The results showed that 89.1% estimated that the cuff pressure was high. Among the participants who rated the cuff pressure as high, 44.8% rated the pressure as quite high and 60.6% rated the pressure as very high. There was no significant relationship between profession and skill in identifying a very high cuff pressure (P = .843) or between work experience and skill in terms of identifying a very high cuff pressure (P = .816). These findings indicate that 10% of patients are at risk of tracheal erosion because of a high cuff pressure.

  13. Probing Combustion Chemistry in a Miniature Shock Tube with Synchrotron VUV Photo Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lynch, Patrick T.; Troy, Tyler P.; Ahmed, Musahid

    2015-01-29

    Tunable synchrotron-sourced photoionization time-of-flight mass spectrometry (PI-TOF-MS) is an important technique in combustion chemistry, complementing lab-scale electron impact and laser photoionization studies for a wide variety of reactors, typically at low pressure. For high-temperature and high-pressure chemical kinetics studies, the shock tube is the reactor of choice. Extending the benefits of shock tube/TOF-MS research to include synchrotron sourced PI-TOF-MS required a radical reconception of the shock tube. An automated, miniature, high-repetition-rate shock tube was developed and can be used to study high-pressure reactive systems (T > 600 K, P < 100 bar) behind reflected shock waves. In this paper, wemore » present results of a PI-TOF-MS study at the Advanced Light Source at Lawrence Berkeley National Laboratory. Dimethyl ether pyrolysis (2% CH3OCH3/Ar) was observed behind the reflected shock (1400 < T-5 < 1700 K, 3 < P-5 < 16 bar) with ionization energies between 10 and 13 eV. Individual experiments have extremely low signal levels. However, product species and radical intermediates are well-resolved when averaging over hundreds of shots, which is ordinarily impractical in conventional shock tube studies. The signal levels attained and data throughput rates with this technique are comparable to those with other synchrotron-based PI-TOF-MS reactors, and it is anticipated that this high pressure technique will greatly complement those lower pressure techniques.« less

  14. Numerical studies on heat transfer and pressure drop characteristics of flat finned tube bundles with various fin materials

    NASA Astrophysics Data System (ADS)

    Peng, Y.; Zhang, S. J.; Shen, F.; Wang, X. B.; Yang, X. R.; Yang, L. J.

    2017-11-01

    The air-cooled heat exchanger plays an important role in the field of industry like for example in thermal power plants. On the other hand, it can be used to remove core decay heat out of containment passively in case of a severe accident circumstance. Thus, research on the performance of fins in air-cooled heat exchangers can benefit the optimal design and operation of cooling systems in nuclear power plants. In this study, a CFD (Computational Fluid Dynamic) method is implemented to investigate the effects of inlet velocity, fin spacing and tube pitch on the flow and the heat transfer characteristics of flat fins constructed of various materials (316L stainless steel, copper-nickel alloy and aluminium). A three dimensional geometric model of flat finned tube bundles with fixed longitudinal tube pitch and transverse tube pitch is established. Results for the variation of the average convective heat transfer coefficient with respect to cooling air inlet velocity, fin spacing, tube pitch and fin material are obtained, as well as for the pressure drop of the cooling air passing through finned tube. It is shown that the increase of cooling air inlet velocity results in enhanced average convective heat transfer coefficient and decreasing pressure drop. Both fin spacing and tube pitch engender positive effects on pressure drop and have negative effects on heat transfer characteristics. Concerning the fin material, the heat transfer performance of copper-nickel alloy is superior to 316L stainless steel and inferior to aluminium.

  15. Intraluminal pressure response in Baerveldt tube shunts: a comparison of modification techniques.

    PubMed

    Gilbert, David D; Bond, Brent

    2007-01-01

    To design an apparatus for in vitro quantification of effects of modifications to nonvalved tube shunts, and to compare the effects of these modifications done to prevent early postoperative hypotony. A testing apparatus was designed and constructed to measure intraluminal pressure (ILP) during constant infusion of balanced salt solution at 2 microL/min through Baerveldt tube shunts mounted on cadaver eyes. Three different modifications were performed and 3 shunts were used for each modification. The modifications were partial tube occlusion with a 3-0 Supramid suture, tube perforation with a 27-gauge needle on an occluded tube, and a 1.2 mm longitudinal venting slit on an occluded tube. The final steady state ILP for the 3-0 Supramid partially occluded tube ranged between 1.6 and 2.8 mm Hg over 3 trials with an average final steady state ILP of 2.0 mm Hg. The 27-gauge needle perforation produced ILPs of 4.6 to 8.2 mm Hg over 3 trials with an average final steady state pressure of 5.9 mm Hg. The 1.2 mm longitudinal venting slit produced an ILP range of 12.6 to 17.3 mm Hg over 3 trials with an average final steady state ILP of 14.8 mm Hg. The differences in final steady state ILP between the 3 modification techniques were statistically significant (P=0.00036). The 3-0 Supramid occlusion and the 27-gauge perforation techniques produced hypotony, whereas the 1.2 mm longitudinal venting slit produced acceptable pressures in vitro.

  16. Pressure wave propagation in fluid-filled co-axial elastic tubes. Part 1: Basic theory.

    PubMed

    Berkouk, K; Carpenter, P W; Lucey, A D

    2003-12-01

    Our work is motivated by ideas about the pathogenesis of syringomyelia. This is a serious disease characterized by the appearance of longitudinal cavities within the spinal cord. Its causes are unknown, but pressure propagation is probably implicated. We have developed an inviscid theory for the propagation of pressure waves in co-axial, fluid-filled, elastic tubes. This is intended as a simple model of the intraspinal cerebrospinal-fluid system. Our approach is based on the classic theory for the propagation of longitudinal waves in single, fluid-filled, elastic tubes. We show that for small-amplitude waves the governing equations reduce to the classic wave equation. The wave speed is found to be a strong function of the ratio of the tubes' cross-sectional areas. It is found that the leading edge of a transmural pressure pulse tends to generate compressive waves with converging wave fronts. Consequently, the leading edge of the pressure pulse steepens to form a shock-like elastic jump. A weakly nonlinear theory is developed for such an elastic jump.

  17. Heat transfer and pressure drop of condensation of hydrocarbons in tubes

    NASA Astrophysics Data System (ADS)

    Fries, Simon; Skusa, Severin; Luke, Andrea

    2018-03-01

    The heat transfer coefficient and pressure drop are investigated for propane. Two different mild steel plain tubes and saturation pressures are considered for varying mass flux and vapour quality. The pressure drop is compared to the Friedel-Correlation with two different approaches to determine the friction factor. The first is calculation as proposed by Friedel and the second is through single phase pressure drop investigations. For lower vapour qualities the experimental results are in better agreement with the approach of the calculated friction factor. For higher vapour qualities the experimental friction factor is more precise. The pressure drop increases for a decreasing tube diameter and saturation pressure. The circumferential temperature profile and heat transfer coefficients are shown for a constant vapour quality at varying mass fluxes. The subcooling is highest for the bottom of the tube and lowest for the top. The average subcooling as well as the circumferential deviation decreases for rising mass fluxes. The averaged heat transfer coefficients are compared to the model proposed by Thome and Cavallini. The experimental results are in good agreement with both correlations, however the trend is better described with the correlation from Thome. The experimental heat transfer coefficients are under predicted by Thome and over predicted by Cavallini.

  18. Abdominal drainage following cholecystectomy: high, low, or no suction?

    PubMed Central

    McCormack, T. T.; Abel, P. D.; Collins, C. D.

    1983-01-01

    A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study failed to demonstrate any clinically useful difference between high negative pressure, low negative pressure, and static drainage system were compared: a simple tube drain, a low negative used, suction is not necessary and a simple tube drain (greater than 6 mm internal diameter) is the most effective form of drainage. PMID:6614773

  19. Experimental perfect-gas study of expansion-tube flow characteristics

    NASA Technical Reports Server (NTRS)

    Shinn, J. L.; Miller, C. G., III

    1978-01-01

    Results of an experimental investigation of expansion tube flow characteristics performed with helium test gas and acceleration gas are presented. The use of helium, eliminates complex real gas chemistry in the comparison of measured and predicted flow quantities. The driver gas was unheated helium at a nominal pressure of 33 MN sq m. The quiescent test gas pressure and quiescent acceleration gas pressure were varied from 0.7 to 50 kN/sq m and from 2.5 to 53 N/sq m, respectively. The effects of tube-wall boundary layer growth and finite secondary diaphragm opening time were examined through the variation of the quiescent gas pressures and secondary diaphragm thickness. Optimum operating conditions for helium test gas were also defined.

  20. Creep-rupture tests of internally pressurized Hastelloy-X tubes

    NASA Technical Reports Server (NTRS)

    Gumto, K. H.; Colantino, G. J.

    1973-01-01

    Seamless Hastelloy-X tubes with 0.375-in. outside diameter and 0.025-in. wall thickness were tested to failure at temperatures from 1400 to 1650 F and internal helium pressures from 800 to 1800 psi. Lifetimes ranged from 58 to 3600 hr. The creep-rupture strength of the tubes was from 20 to 40 percent lower than that of sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.

  1. Stress analysis and failure of an internally pressurized composite-jacketed steel cylinder

    NASA Technical Reports Server (NTRS)

    Chen, Peter C. T.

    1992-01-01

    This paper presents a nonlinear stress analysis of a thick-walled compound tube subjected to internal pressure. The compound tube is constructed of a steel liner and a graphite-bismaleimide outer shell. Analytical expressions for the stresses, strains, and displacements are derived for all loading ranges up to failure. Numerical results for the stresses and the maximum value that the compound tube can contain without failure are presented.

  2. Risks for Heart Disease & Stroke

    MedlinePlus

    ... Heart Disease Stroke High Blood Pressure Cholesterol Salt Video: Know Your Risk Factors YouTube embed video: YouTube ... https://www.youtube-nocookie.com/embed/GQ0f7-ksmGI Video: José’s Story YouTube embed video: YouTube embed video: ...

  3. Buckling of thin walled composite cylindrical shell filled with solid propellant

    NASA Astrophysics Data System (ADS)

    Dash, A. P.; Velmurugan, R.; Prasad, M. S. R.

    2017-12-01

    This paper investigates the buckling of thin walled composite cylindrical tubes that are partially filled with solid propellant equivalent elastic filler. Experimental investigation is conducted on thin composite tubes made out of S2-glass epoxy, which is made by using filament winding technique. The composite tubes are filled with elastic filler having similar mechanical properties as that of a typical solid propellant used in rocket motors. The tubes are tested for their buckling strength against the external pressure in the presence of the filler. Experimental data confirms the enhancement of external pressure carrying capacity of the composite tubes by up to three times as that of empty tubes for a volumetric loading fraction (VLF) of 0.9. Furthermore, the finite element based geometric nonlinearity analysis predicts the buckling behaviour of the partially filled composite tubes close to the experimental results.

  4. Large co-axial pulse tube preliminary results

    NASA Astrophysics Data System (ADS)

    Emery, N.; Caughley, A.; Meier, J.; Nation, M.; Tanchon, J.; Trollier, T.; Ravex, A.

    2014-01-01

    We report that Callaghan Innovation, formally known as Industrial Research Ltd (IRL), has designed and built its largest of three high frequency single-stage co-axial pulse tubes, closely coupled to a metal diaphragm pressure wave generator (PWG). The previous pulse tube achieved 110 W of cooling power @ 77 K, with an electrical input power of 3.1 kW from a 90 cc swept volume PWG. The pulse tubes have all been tuned to operate at 50 Hz, with a mean helium working pressure of 2.5 MPa. Sage pulse tube simulation software was used to model the latest pulse tube and predicted 280 W of cooling power @ 77 K. The nominal 250 W cryocooler was designed to be an intermediate step to up-scale pulse tube technology for our 1000 cc swept-volume PWG, to provide liquefaction of gases and cooling for HTS applications. Details of the modeling, design, development and preliminary experimental results are discussed.

  5. Dynamics of Magnetic Flux Tubes in an Advective Flow around a Black Hole

    NASA Astrophysics Data System (ADS)

    Deb, Arnab; Chakrabarti, Sandip Kumar; Giri, Kinsuk

    2016-07-01

    Magnetic fields cannibalized by an accretion flow would very soon have a dominant toroidal component. Without changing the topology, we study the movements of these flux tubes inside a geometrically thick advective disk which undergo centrifugal pressure supported shocks. We also consider the effects of the flux tubes on the flow. We use a finite element method (Total Variation Diminishing) for this purpose and specifically focussed whether the flux tubes contribute to changes in outflow properties in terms of its collimation and outflow rates. It is seen that depending upon the cross sectional radius of the flux tubes (which control the drag force), these field lines may move towards the central object or oscillate vertically before eventually escaping out of the funnel wall (pressure zero surface). These interesting results obtained with and without flux tubes point to the role the flux tubes play in collimation of jets and outflows.

  6. Expansion tube test time predictions

    NASA Technical Reports Server (NTRS)

    Gourlay, Christopher M.

    1988-01-01

    The interaction of an interface between two gases and strong expansion is investigated and the effect on flow in an expansion tube is examined. Two mechanisms for the unsteady Pitot-pressure fluctuations found in the test section of an expansion tube are proposed. The first mechanism depends on the Rayleigh-Taylor instability of the driver-test gas interface in the presence of a strong expansion. The second mechanism depends on the reflection of the strong expansion from the interface. Predictions compare favorably with experimental results. The theory is expected to be independent of the absolute values of the initial expansion tube filling pressures.

  7. Occurrence of turbulent flow conditions in supercritical fluid chromatography.

    PubMed

    De Pauw, Ruben; Choikhet, Konstantin; Desmet, Gert; Broeckhoven, Ken

    2014-09-26

    Having similar densities as liquids but with viscosities up to 20 times lower (higher diffusion coefficients), supercritical CO2 is the ideal (co-)solvent for fast and/or highly efficient separations without mass-transfer limitations or excessive column pressure drops. Whereas in liquid chromatography the flow remains laminar in both the packed bed and tubing, except in extreme cases (e.g. in a 75 μm tubing, pure acetonitrile at 5 ml/min), a supercritical fluid can experience a transition from laminar to turbulent flow in more typical operation modes. Due to the significant lower viscosity, this transition for example already occurs at 1.3 ml/min for neat CO2 when using connection tubing with an ID of 127 μm. By calculating the Darcy friction factor, which can be plotted versus the Reynolds number in a so-called Moody chart, typically used in fluid dynamics, higher values are found for stainless steel than PEEK tubing, in agreement with their expected higher surface roughness. As a result turbulent effects are more pronounced when using stainless steel tubing. The higher than expected extra-column pressure drop limits the kinetic performance of supercritical fluid chromatography and complicates the optimization of tubing ID, which is based on a trade-off between extra-column band broadening and pressure drop. One of the most important practical consequences is the non-linear increase in extra-column pressure drop over the tubing downstream of the column which leads to an unexpected increase in average column pressure and mobile phase density, and thus decrease in retention. For close eluting components with a significantly different dependence of retention on density, the selectivity can significantly be affected by this increase in average pressure. In addition, the occurrence of turbulent flow is also observed in the detector cell and connection tubing. This results in a noise-increase by a factor of four when going from laminar to turbulent flow (e.g. going from 0.5 to 2.5 ml/min for neat CO2). Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Heat Transfer Enhancement for Finned-Tube Heat Exchangers with Vortex Generators: Experimental and Numerical Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Brien, James Edward; Sohal, Manohar Singh; Huff, George Albert

    2002-08-01

    A combined experimental and numerical investigation is under way to investigate heat transfer enhancement techniques that may be applicable to large-scale air-cooled condensers such as those used in geothermal power applications. The research is focused on whether air-side heat transfer can be improved through the use of finsurface vortex generators (winglets,) while maintaining low heat exchanger pressure drop. A transient heat transfer visualization and measurement technique has been employed in order to obtain detailed distributions of local heat transfer coefficients on model fin surfaces. Pressure drop measurements have also been acquired in a separate multiple-tube row apparatus. In addition, numericalmore » modeling techniques have been developed to allow prediction of local and average heat transfer for these low-Reynolds-number flows with and without winglets. Representative experimental and numerical results presented in this paper reveal quantitative details of local fin-surface heat transfer in the vicinity of a circular tube with a single delta winglet pair downstream of the cylinder. The winglets were triangular (delta) with a 1:2 height/length aspect ratio and a height equal to 90% of the channel height. Overall mean fin-surface Nusselt-number results indicate a significant level of heat transfer enhancement (average enhancement ratio 35%) associated with the deployment of the winglets with oval tubes. Pressure drop measurements have also been obtained for a variety of tube and winglet configurations using a single-channel flow apparatus that includes four tube rows in a staggered array. Comparisons of heat transfer and pressure drop results for the elliptical tube versus a circular tube with and without winglets are provided. Heat transfer and pressure-drop results have been obtained for flow Reynolds numbers based on channel height and mean flow velocity ranging from 700 to 6500.« less

  9. Fluid flow monitoring device

    DOEpatents

    McKay, M.D.; Sweeney, C.E.; Spangler, B.S. Jr.

    1993-11-30

    A flow meter and temperature measuring device are described comprising a tube with a body centered therein for restricting flow and a sleeve at the upper end of the tube to carry several channels formed longitudinally in the sleeve to the appropriate axial location where they penetrate the tube to allow pressure measurements and temperature measurements with thermocouples. The high pressure measurement is made using a channel penetrating the tube away from the body and the low pressure measurement is made at a location at the widest part of the body. An end plug seals the end of the device and holes at its upper end allow fluid to pass from the interior of the tube into a plenum. The channels are made by cutting grooves in the sleeve, the grooves widened at the surface of the sleeve and then a strip of sleeve material is welded to the grooves closing the channels. Preferably the sleeve is packed with powdered graphite before cutting the grooves and welding the strips. 7 figures.

  10. Condensation heat transfer and pressure drop of R-410A in flat aluminum multi-port tubes

    NASA Astrophysics Data System (ADS)

    Kim, Nae-Hyun

    2018-02-01

    Brazed heat exchangers with aluminum flat multi-port tubes are being used as condensers of residential air-conditioners. In this study, R-410A condensation tests were conducted in four multi-port tubes having a range of hydraulic diameter (0.78 ≤ Dh ≤ 0.95 mm). The test range covered the mass flux from 100 to 400 kg/m2 s and the heat flux at 3 kW/m2, which are typical operating conditions of residential air conditioners. Results showed that both the heat transfer coefficient and the pressure drop increased as the hydraulic diameter decreased. The effect of hydraulic diameter on condensation heat transfer was much larger than the predictions of existing correlations for the range of investigation. Comparison of the data with the correlations showed that some macro-channel tube correlations and mini-channel tube correlations reasonably predicted the heat transfer coefficient. However, macro-channel correlations highly overpredicted the pressure drop data.

  11. The measurement of Eustachian tube function in a hyperbaric chamber using an ear canal microphone.

    PubMed

    Fischer, Hans-Georg; Koch, Andreas; Kähler, Wataru; Pohl, Michael; Pau, Hans-Wilhelm; Zehlicke, Thorsten

    2016-03-01

    The purpose of this study was to further the understanding of the opening of the Eustachian tube in relation to changes in barometric pressure. An ear canal microphone was used to measure the specific sounds related to tube opening and possible eardrum movements. Five subjects with normal tube function were examined in a hyperbaric chamber (up to 304 kPa). All active and passive equalization events were recorded and correlated with the subjectively perceived pressure regulation in the measured ear. The signals recorded were clear and reproducible. The acoustic analysis distinguished between the different kinds of equalization. Subjective impressions were confirmed by the recorded frequency of acoustic phenomena (clicks). During compression, the sequence of active equalization manoeuvres was in a more regular and steady pattern than during decompression, when the click sounds varied. The study established a simple technical method for analyzing the function of the Eustachian tube and provided new information about barometric pressure regulation of the middle ear.

  12. Poiseuille's Law--Showing that "p" Is Inversely Proportional to R[superscript 4] Using the Shell Method

    ERIC Educational Resources Information Center

    Drost, John P.; Georges, Rachel A.

    2004-01-01

    Jean Poiseuille, a physician, developed a mercury filled U-tube to measure blood pressure in 1828. He discovered that pressure in veins is significantly lower than pressure in arteries. As a result, he studied liquid flow in small tubes. A few years later he established Poiseuille's Law, which states the resistance, "p," of the flow of blood as…

  13. Repair of a vesicocutaneous fistula using negative-pressure wound therapy and urinary diversion via a nephrostomy tube.

    PubMed

    Freeman, Julie J; Storto, Dominic L P; Berry-Cabán, Cristóbal S

    2013-01-01

    This article describes an unusual case of a vesicocutaneous fistula in a patient with a history of radiation therapy and recent abdominal surgery. A 61-year-old woman was transferred to our acute care facility from a rehabilitation facility, with poor nutritional intake and a concern for urine draining from her wound. A nephrostomy tube was placed (she had only 1 functioning kidney) and negative-pressure wound therapy was used to close the fistula. Urinary diversion via a nephrostomy tube and negative-pressure wound therapy were used to successfully and safely close this vesicocutaneous fistula.

  14. Acoustic levitation

    NASA Astrophysics Data System (ADS)

    Hansen, Uwe J.

    2005-09-01

    A speaker, driven by an amplified audio signal is used to set up a standing wave in a 3b-ft-long, 4-in.-diam transparent tube. Initially the tube is oriented horizontally, and Styrofoam packing peanuts accumulate near the pressure nodes. When the tube is turned to a position with the axis oriented vertically, the peanuts drop slightly, until the gravitational force on the peanuts is balanced by the force due to the sound pressure, at which point levitation is observed. Sound-pressure level measurements are used to map the air column normal mode pattern. Similarly, standing waves are established between an ultrasonic horn and a metal reflector and millimeter size Styrofoam balls are levitated.

  15. STEAM GENERATOR FOR GAS COOLED NUCLEAR REACTORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1960-03-14

    A steam generator for a gas-cooled nuclear reactor is disposed inside the same pressure vessel as the reactor and has a tube system heated by the gas circulating through the reactor; the pressure vessel is double-walled, and the interspace between these two walls is filled with concrete serving as radiation shielding. The steam generator has a cylindricaIly shaped vertical casing, through which the heating gas circulates, while the tubes are arranged in a plurality of parallel horizontal planes and each of them have the shape of an involute of a circle. The tubes are uniformly distributed over the available surfacemore » in the plane, all the tubes of the same plane being connected in parallel. The exterior extremities of these involute-shaped tubes are each connected with similar tubes disposed in the adjacent lower situated plane, while the interior extremities are connected with tubes in the adjacent higher situated plane. The alimentation of the tubes is performed over annular headers. The tube system is self-supporting, the tubes being joined together by welded spacers. The fluid flow in the tubes is performed by forced circulation. (NPO)« less

  16. Effect of Mixture Pressure and Equivalence Ratio on Detonation Cell Size for Hydrogen-Air Mixtures

    DTIC Science & Technology

    2015-06-01

    National Labs ( BNL ) built and tested several detonation tubes with hydrogen and air detonations. BNL’s main detonation tubes were called the High...K and the ability to change to mixture pressure from one atmosphere to just less than three atmospheres. Before BNL designed their detonation tubes...gas driver initiation system was that the diaphragm had to be replaced after each test. In order to save time from replacing the diaphragms, BNL

  17. Ultrasonic analyte concentration and application in flow cytometry

    DOEpatents

    Kaduchak, Gregory; Goddard, Greg; Salzman, Gary; Sinha, Dipen; Martin, John C.; Kwiatkowski, Christopher; Graves, Steven

    2014-07-22

    The present invention includes an apparatus and corresponding method for concentrating analytes within a fluid flowing through a tube using acoustic radiation pressure. The apparatus includes a function generator that outputs a radio frequency electrical signal to a transducer that transforms the radio frequency electric signal to an acoustic signal and couples the acoustic signal to the tube. The acoustic signal is converted within the tube to acoustic pressure that concentrates the analytes within the fluid.

  18. Ultrasonic analyte concentration and application in flow cytometry

    DOEpatents

    Kaduchak, Gregory [Los Alamos, NM; Goddard, Greg [Los Alamos, NM; Salzman, Gary [White Rock, NM; Sinha, Dipen [Los Alamos, NM; Martin, John C [Los Alamos, NM; Kwiatkowski, Christopher [Los Alamos, NM; Graves, Steven [San Juan Pueblo, NM

    2008-03-11

    The present invention includes an apparatus and corresponding method for concentrating analytes within a fluid flowing through a tube using acoustic radiation pressure. The apparatus includes a function generator that outputs a radio frequency electrical signal to a transducer that transforms the radio frequency electric signal to an acoustic signal and couples the acoustic signal to the tube. The acoustic signal is converted within the tube to acoustic pressure that concentrates the analytes within the fluid.

  19. Ultrasonic analyte concentration and application in flow cytometry

    DOEpatents

    Kaduchak, Gregory; Goddard, Greg; Salzman, Gary; Sinha, Dipen; Martin, John C.; Kwiatkowski, Christopher; Graves, Steven

    2015-07-07

    The present invention includes an apparatus and corresponding method for concentrating analytes within a fluid flowing through a tube using acoustic radiation pressure. The apparatus includes a function generator that outputs a radio frequency electrical signal to a transducer that transforms the radio frequency electric signal to an acoustic signal and couples the acoustic signal to the tube. The acoustic signal is converted within the tube to acoustic pressure that concentrates the analytes within the fluid.

  20. Bifurcation of finitely deformed thick-walled electroelastic cylindrical tubes subject to a radial electric field

    NASA Astrophysics Data System (ADS)

    Melnikov, Andrey; Ogden, Ray W.

    2018-06-01

    This paper is concerned with the bifurcation analysis of a pressurized electroelastic circular cylindrical tube with closed ends and compliant electrodes on its curved boundaries. The theory of small incremental electroelastic deformations superimposed on a finitely deformed electroelastic tube is used to determine those underlying configurations for which the superimposed deformations do not maintain the perfect cylindrical shape of the tube. First, prismatic bifurcations are examined and solutions are obtained which show that for a neo-Hookean electroelastic material prismatic modes of bifurcation become possible under inflation. This result contrasts with that for the purely elastic case for which prismatic bifurcation modes were found only for an externally pressurized tube. Second, axisymmetric bifurcations are analyzed, and results for both neo-Hookean and Mooney-Rivlin electroelastic energy functions are obtained. The solutions show that in the presence of a moderate electric field the electroelastic tube becomes more susceptible to bifurcation, i.e., for fixed values of the axial stretch axisymmetric bifurcations become possible at lower values of the circumferential stretches than in the corresponding problems in the absence of an electric field. As the magnitude of the electric field increases, however, the possibility of bifurcation under internal pressure becomes restricted to a limited range of values of the axial stretch and is phased out completely for sufficiently large electric fields. Then, axisymmetric bifurcation is only possible under external pressure.

  1. Experimental investigation of spontaneous ignition and flame propagation at pressurized hydrogen release through tubes with varying cross-section.

    PubMed

    Duan, Qiangling; Xiao, Huahua; Gao, Wei; Gong, Liang; Sun, Jinhua

    2016-12-15

    An experimental investigation of spontaneous ignition and flame propagation at high-pressure hydrogen release via cylindrical tubes with varying cross-section is presented. Tubes with different transverse cross-sections are considered in the experiments: (1) local contraction, (2) local enlargement, (3) abrupt contraction, and (4) abrupt enlargement. The results show that the presence of the varying cross-section geometries can significantly promote the occurrence of spontaneous ignition. Compared to the tube with constant cross-section, the minimum pressure release needed for spontaneous ignition for the varying cross-sections tubes is considerably lower. Moreover, the initial ignition location is closer to the disk in the presence of varying cross-section geometries in comparison with straight channel. As the flame emerges from the outlet of the tube, the velocity of the flame front in the vicinity of the nozzle increases sharply. Then, a deflagration develops across the mixing zone of hydrogen/air mixture. The maximum deflagration overpressure increases linearly with the release pressure. Subsequently, a hydrogen jet flame is produced and evolves different shapes at different release stages. A fireball is formed after the jet flame spouts in the open air. Later, the fireball develops into a jet flame which shifts upward and continues to burn in the vertical direction. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. A Numerical Process Control Method for Circular-Tube Hydroforming Prediction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Kenneth I.; Nguyen, Ba Nghiep; Davies, Richard W.

    2004-03-01

    This paper describes the development of a solution control method that tracks the stresses, strains and mechanical behavior of a tube during hydroforming to estimate the proper axial feed (end-feed) and internal pressure loads through time. The analysis uses the deformation theory of plasticity and Hill?s criterion to describe the plastic flow. Before yielding, the pressure and end-feed increments are estimated based on the initial tube geometry, elastic properties and yield stress. After yielding, the pressure increment is calculated based on the tube geometry at the previous solution increment and the current hoop stress increment. The end-feed increment is computedmore » from the increment of the axial plastic strain. Limiting conditions such as column buckling (of long tubes), local axi-symmetric wrinkling of shorter tubes, and bursting due to localized wall thinning are considered. The process control method has been implemented in the Marc finite element code. Hydroforming simulations using this process control method were conducted to predict the load histories for controlled expansion of 6061-T4 aluminum tubes within a conical die shape and under free hydroforming conditions. The predicted loading paths were transferred to the hydroforming equipment to form the conical and free-formed tube shapes. The model predictions and experimental results are compared for deformed shape, strains and the extent of forming at rupture.« less

  3. Gay-Lussac Experiment

    ERIC Educational Resources Information Center

    Ladino, L. A.; Rondón, S. H.

    2015-01-01

    In this paper, we present a low-cost method to study the Gay-Lussac's law. We use a heating wire wrapped around the test tube to heat the air inside and make use of a solid state pressure sensor which requires a previous calibration to measure the pressure in the test tube.

  4. A research program to reduce interior noise in general aviation airplanes: Investigation of the characteristics of an acoustic panel test facility

    NASA Technical Reports Server (NTRS)

    Grosveld, F.; Vanaken, J.

    1978-01-01

    Sound pressure levels in the test facility were studied that are caused by varying: (1) microphone positions; (2) equalizer setting; and (3) panel clamping forces. Measurements were done by using a Beranek tube or this Beranek tube in combinations with an extension tube and a special test section. In all configurations tests were executed with and without a test panel installed. The influence of the speaker back panel and the back panel of the Beranek tube on the sound pressure levels inside the test tube were also investigated. It is shown that the definition of noise reduction is more useful in relation to this test facility than transmission loss.

  5. Aluminum Hydride as a Fuel Supplement to NanoThermites

    DTIC Science & Technology

    2014-01-01

    nanocomposite thermite based on CuO, Bi2O3, and Fe2O3. Pressure cell and burn tube experiments demonstrated enhancements in absolute pressure...pressurization rate, and burning velocity when micron-scale aluminum hydride was used as a minor fuel component in a nanoaluminum–copper-oxide thermite ...alane, AlH3) replaced nanoaluminum incrementally as a fuel in a nanocomposite thermite based on CuO, Bi2O3, and Fe2O3. Pressure cell and burn tube

  6. Echocardiographic evaluation during weaning from mechanical ventilation

    PubMed Central

    Schifelbain, Luciele Medianeira; Vieira, Silvia Regina Rios; Brauner, Janete Salles; Pacheco, Deise Mota; Naujorks, Alexandre Antonio

    2011-01-01

    INTRODUCTION: Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. OBJECTIVES: To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T‐tube; and comparing patient subgroups: success vs. failure in weaning. METHODS: Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T‐tube. Pressure support ventilation vs. T‐tube and weaning success vs. failure were compared using ANOVA and Student's t‐test. The level of significance was p<0.05. RESULTS: Twenty‐four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T‐tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. CONCLUSION: No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T‐tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients. PMID:21437445

  7. Phase velocity enhancement of linear explosive shock tubes

    NASA Astrophysics Data System (ADS)

    Loiseau, Jason; Serge, Matthew; Szirti, Daniel; Higgins, Andrew; Tanguay, Vincent

    2011-06-01

    Strong, high density shocks can be generated by sequentially detonating a hollow cylinder of explosives surrounding a thin-walled, pressurized tube. Implosion of the tube results in a pinch that travels at the detonation velocity of the explosive and acts like a piston to drive a shock into the gas ahead of it. In order to increase the maximum shock velocities that can be obtained, a phase velocity generator can be used to drag an oblique detonation wave along the gas tube at a velocity much higher than the base detonation velocity of the explosive. Since yielding and failure of the gas tube is the primary limitation of these devices, it is desirable to retain the dynamic confinement effects of a heavy-walled tamper without interfering with operation of the phase velocity generator. This was accomplished by cutting a slit into the tamper and introducing a phased detonation wave such that it asymmetrically wraps around the gas tube. This type of configuration has been previously experimentally verified to produce very strong shocks but the post-shock pressure and shock velocity limits have not been investigated. This study measured the shock trajectory for various fill pressures and phase velocities to ascertain the limiting effects of tube yield, detonation obliquity and pinch aspect ratio.

  8. Coaxial Tubing Systems Increase Artificial Airway Resistance and Work of Breathing.

    PubMed

    Wenzel, Christin; Schumann, Stefan; Spaeth, Johannes

    2017-09-01

    Tubing systems are an essential component of the ventilation circuit, connecting the ventilator to the patient's airways. Coaxial tubing systems incorporate the inspiratory tube within the lumen of the expiratory one. We hypothesized that by design, these tubing systems increase resistance to air flow compared with conventional ones. We investigated the flow-dependent pressure gradient across coaxial, conventional disposable, and conventional reusable tubing systems from 3 different manufacturers. Additionally, the additional work of breathing and perception of resistance during breathing through the different devices were determined in 18 healthy volunteers. The pressure gradient across coaxial tubing systems was up to 6 times higher compared with conventional ones (1.90 ± 0.03 cm H 2 O vs 0.34 ± 0.01 cm H 2 O, P < .001) and was higher during expiration compared with inspiration ( P < .001). Additional work of breathing and perceived breathing resistance were highest in coaxial tubing systems, accordingly. Our findings suggest that the use of coaxial tubing systems should be carefully considered with respect to their increased resistance. Copyright © 2017 by Daedalus Enterprises.

  9. Combustion of Micro- and Nanothermites under Elevating Pressure

    NASA Astrophysics Data System (ADS)

    Monogarov, K.; Pivkina, Alla; Muravyev, N.; Meerov, D.; Dilhan, D.

    Non-equilibrium process of combustion-wave propagation of thermite compositions (Mg/Fe2O3) inside the sealed steel tube have been investigated to study the burning rate at elevating pressure. Under confinement the hot gas-phase products, formed during thermite combustion result in considerable overpressure inside the tube that reverses the gas flow and leads to pressure-driven preheating effect of the burned-gas permeation. Convective origin of this preheating effect is discussed. The pressure-time dependency is obtained experimentally. The composition was pressed inside the steel tube in pellets; the size of each part was measured to obtain burning rate - pressure dependency. Both micro- and nanosized components were used to prepare thermite compositions under study. The significant difference in burning parameters of micron- and nanosized thermites is observed and analyzed. Based on obtained results, the combustion mechanism of thermites with the micro- and nanosized components is discussed.

  10. Mechanism for Increasing the Pressure in an Oil Well by a Combustible Oxidizing Liquid Mixture

    NASA Astrophysics Data System (ADS)

    Melik-Gaikazov, G. V.

    2014-09-01

    A method of estimating the pressure pulse arising in a deep oil well as a result of the thermal explosion of a combustible oxidizing liquid mixture in it is presented. It was established that less than 10% of this mixture is expended for the formation of a pressure pulse in this well. The conditions under which a tubing string positioned in such a well experiences a plastic bending and its walls are crumpled were determined. The maximum admissible difference between the pressures at the walls of this tube were calculated, and axial compression loads were related to critical forces of different orders. It is shown that, when the indicated tube is submerged in the liquid in the well, its resistance to a short-time axial compression load increases.

  11. Circumferential pressure probe

    NASA Technical Reports Server (NTRS)

    Holmes, Harlan K. (Inventor); Moore, Thomas C. (Inventor); Fantl, Andrew J. (Inventor)

    1989-01-01

    A probe for measuring circumferential pressure inside a body cavity is disclosed. In the preferred embodiment, a urodynamic pressure measurement probe for evaluating human urinary sphincter function is disclosed. Along the length of the probe are disposed a multiplicity of deformable wall sensors which typically comprise support tube sections with flexible side wall areas. These are arranged along the length of the probe in two areas, one just proximal to the tip for the sensing of fluid pressure inside the bladder, and five in the sensing section which is positioned within the urethra at the point at which the urinary sphincter constricts to control the flow of urine. The remainder of the length of the probe comprises multiple rigid support tube sections interspersed with flexible support tube sections in the form of bellows to provide flexibility.

  12. Economic method for measuring ultra-low flow rates of fluids

    NASA Technical Reports Server (NTRS)

    Bogdanovic, J. A.; Keller, W. F.

    1970-01-01

    Capillary tube flowmeter measures ultra-low flows of very corrosive fluids /such as chlorine trifluoride and liquid fluorine/ and other liquids with reasonable accuracy. Flowmeter utilizes differential pressure transducer and operates on the principle that for laminar flow in the tube, pressure drop is proportional to flow rate.

  13. 31. DETAIL OF PRESSURE GAUGE AND ASSOCIATED VALVES AND TUBING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. DETAIL OF PRESSURE GAUGE AND ASSOCIATED VALVES AND TUBING FOR STRETCH SLING CYLINDER. GAUGE LOCATED IN SOUTHWEST CORNER OF SLC-3W MST STATION 78. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. Distillation device supplies cesium vapor at constant pressure

    NASA Technical Reports Server (NTRS)

    Basiulis, A.; Shefsiek, P. K.

    1968-01-01

    Distillation apparatus in the form of a U tube supplies small amounts of pure cesium vapor at constant pressure to a thermionic converter. The upstream leg of the U tube is connected to a vacuum pump to withdraw noncondensable impurities, the bottom portion serves as a reservoir for the liquid cesium.

  15. 30 CFR 250.618 - Tubing and wellhead equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... following requirements during well-workover operations with the tree removed: (a) No tubing string shall be... pressure integrity and is otherwise suitable for its intended use. (b) In the event of prolonged operations... Manager. (c) When reinstalling the tree, you must: (1) Equip wells to monitor for casing pressure...

  16. 78 FR 17285 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-21

    ... inspections for dirt, loose particles, or blockage of the flanged tube and drain hole for the pressure seals... aft pressure seals; doing repetitive inspections for dirt, loose particles, or blockage of the flanged... AD, do a general visual inspection for dirt, loose particles, and blockage of the flanged tube and...

  17. On the Quantitative Analysis of Liquid Flow in Physiological Tubes.

    DTIC Science & Technology

    1982-12-01

    cri- copharyngeal sphincter which is aided by skeletal muscle (Vantrap- pen and hellemans, 1980) relaxes to accept the bolus and the gastro - esophageal ...lower ( gastro -) esophageal junction during peristalsis resulting from the interaction of gastric, esophageal and thoracic pressures. PIP is a pressure...higher than the downstream pressure and a flow velocity profile with no reflux (syn.: retropulsion). The 5 Pumping in Biological Tubes a. Peristaltic

  18. Two-tier tube-trailer pressure consolidation operation method for hydrogen refueling station cost reduction

    DOE PAGES

    Reddi, Krishna; Elgowainy, Amgad; Rustagi, Neha; ...

    2018-01-10

    An operation strategy known as two-tier “pressure consolidation” of delivered tube-trailers (or equivalent supply storage) has been developed to maximize the throughput at gaseous hydrogen refueling stations (HRSs) for fuel cell electric vehicles (FCEVs). The high capital costs of HRSs and the consequent high investment risk are deterring growth of the infrastructure needed to promote the deployment of FCEVs. Stations supplied by gaseous hydrogen will be necessary for FCEV deployment in both the near and long term. Here, the two-tier pressure consolidation method enhances gaseous HRSs in the following ways: (1) reduces the capital cost compared with conventional stations, asmore » well as those operating according to the original pressure consolidation approach described by Elgowainy et al. (2014) [1], (2) minimizes pressure cycling of HRS supply storage relative to the original pressure consolidation approach; and (3) increases use of the station’s supply storage (or delivered tube-trailers) while maintaining higher state-of-charge vehicle fills.« less

  19. Two-tier tube-trailer pressure consolidation operation method for hydrogen refueling station cost reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddi, Krishna; Elgowainy, Amgad; Rustagi, Neha

    An operation strategy known as two-tier “pressure consolidation” of delivered tube-trailers (or equivalent supply storage) has been developed to maximize the throughput at gaseous hydrogen refueling stations (HRSs) for fuel cell electric vehicles (FCEVs). The high capital costs of HRSs and the consequent high investment risk are deterring growth of the infrastructure needed to promote the deployment of FCEVs. Stations supplied by gaseous hydrogen will be necessary for FCEV deployment in both the near and long term. Here, the two-tier pressure consolidation method enhances gaseous HRSs in the following ways: (1) reduces the capital cost compared with conventional stations, asmore » well as those operating according to the original pressure consolidation approach described by Elgowainy et al. (2014) [1], (2) minimizes pressure cycling of HRS supply storage relative to the original pressure consolidation approach; and (3) increases use of the station’s supply storage (or delivered tube-trailers) while maintaining higher state-of-charge vehicle fills.« less

  20. The Propagation of a Liquid Bolus Through an Elastic Tube and Airway Reopening

    NASA Technical Reports Server (NTRS)

    Howell, Peter D.; Grotberg, James B.

    1996-01-01

    We use lubrication theory and matched asymptotic expansions to model the quasi-steady propagation of a liquid bridge through an elastic tube. In the limit of small capillary number, asymptotic expressions are found for the pressure drop across the bridge and the thickness of the liquid film left behind, as functions of the capillary number, the thickness of the liquid lining ahead of the bridge and the elastic characteristics of the tube wall. For a given precursor thickness, we find a critical propagation speed, and hence a critical imposed pressure drop, above which the bridge will eventually burst, and hence the tube will reopen.

  1. Nonlinear oscillations of gas in an open tube near the resonance frequency in the shock-free mode

    NASA Astrophysics Data System (ADS)

    Tkachenko, L. A.; Sergienko, M. V.

    2014-11-01

    The forced oscillations of gas in an open tube, excited by harmonical oscillations of piston in the shock-free mode were investigated near the first first eigenfrequencies. An expression for the pressure oscillations of gas was obtained for the tube with unrounded end without flange. The amplitude impact of piston displacement on the oscillations of pressure and velocity of the secondary flow of gas was investigated. The comparison of theoretical calculations with experimental data was executed. The effect of secondary flow on the particle drift along the tube axis with acoustic oscillations of gas was shown.

  2. [Continuous inflation of a leaking cuff of an intubation tube].

    PubMed

    Boussard, N; Helmer, J; Rose, E; Lascombes, P

    1988-01-01

    Perforation of the cuff of the endotracheal tube peroperatively is a very serious problem, especially when it occurs in a patient prone on an orthopaedic table. This is even more dramatic when the patient is not breathing spontaneously and he cannot be turned over to be reintubated. Given the unusual character of this situation, an apparatus has been designed to keep the cuff inflated permanently. It was a circuit consisting of a manual pressure valve, flexible tubing, a peripheral catheter and the cuff supply tube. The gas used was medical air at 3 bar pressure. This method proved perfectly safe and efficient, the operation having continued without reintubation.

  3. Restrike Particle Beam Experiments on a Dense Plasma Focus.

    DTIC Science & Technology

    1980-11-30

    differentially pumped drift tube as shown in Figure 1. However, even the lOI of gas pressure in the drift space is sufficient to establish an equilibrium...pumped drift tube concept are five-fold: 1) Lower energy attenuation of the beam by neutral gas 2) Lower lateral spread of the beam caused by multiple...relatively low gas pressure through the use of a differentially pumped drift tube . The path makes it possible to observe ion energies to considerably lower

  4. Determination of soluble bromine in an extra-high-pressure mercury discharge lamp by sodium hydroxide decomposition-suppressed ion chromatography.

    PubMed

    Mitsumata, Hiroshi; Mori, Toshio; Maeda, Tatsuo; Kita, Yoshiyuki; Kohatsu, Osamu

    2006-02-01

    We have established a simple method for assaying the quantity of soluble bromine in the discharge tubes of an extra-high-pressure mercury discharge lamp. Each discharge tube is destroyed in 5 ml of 10 mM sodium hydroxide, and the recovered sodium hydroxide solution is analyzed by suppressed-ion chromatography using gradient elution. We have clarified that this method can assay less than 1 microg of soluble bromine in a discharge tube.

  5. Thermal Performance of Microencapsulated Phase Change Material Slurry

    DTIC Science & Technology

    2008-03-01

    the enhanced tubing to account for the microfin enhancement size. Figure 4.2 suggests that a roughness factor value for an 8 mm enhanced tubing ...After taking into account the enhanced tubing additional surface area, it can be concluded that that the microfins or enhancements on the tubing ...39 4.2 Pressure drop of water with 8 mm enhanced tubing

  6. Thermal Performance of Microencapsulated Phase Change Material Survey

    DTIC Science & Technology

    2008-03-01

    the enhanced tubing to account for the microfin enhancement size. Figure 4.2 suggests that a roughness factor value for an 8 mm enhanced tubing ...After taking into account the enhanced tubing additional surface area, it can be concluded that that the microfins or enhancements on the tubing ...39 4.2 Pressure drop of water with 8 mm enhanced tubing

  7. Tailoring the Blast Exposure Conditions in the Shock Tube for Generating Pure, Primary Shock Waves: The End Plate Facilitates Elimination of Secondary Loading of the Specimen

    PubMed Central

    Misistia, Anthony; Kahali, Sudeepto; Sundaramurthy, Aravind; Chandra, Namas

    2016-01-01

    The end plate mounted at the mouth of the shock tube is a versatile and effective implement to control and mitigate the end effects. We have performed a series of measurements of incident shock wave velocities and overpressures followed by quantification of impulse values (integral of pressure in time domain) for four different end plate configurations (0.625, 2, 4 inches, and an open end). Shock wave characteristics were monitored by high response rate pressure sensors allocated in six positions along the length of 6 meters long 229 mm square cross section shock tube. Tests were performed at three shock wave intensities, which was controlled by varying the Mylar membrane thickness (0.02, 0.04 and 0.06 inch). The end reflector plate installed at the exit of the shock tube allows precise control over the intensity of reflected waves penetrating into the shock tube. At the optimized distance of the tube to end plate gap the secondary waves were entirely eliminated from the test section, which was confirmed by pressure sensor at T4 location. This is pronounced finding for implementation of pure primary blast wave animal model. These data also suggest only deep in the shock tube experimental conditions allow exposure to a single shock wave free of artifacts. Our results provide detailed insight into spatiotemporal dynamics of shock waves with Friedlander waveform generated using helium as a driver gas and propagating in the air inside medium sized tube. Diffusion of driver gas (helium) inside the shock tube was responsible for velocity increase of reflected shock waves. Numerical simulations combined with experimental data suggest the shock wave attenuation mechanism is simply the expansion of the internal pressure. In the absence of any other postulated shock wave decay mechanisms, which were not implemented in the model the agreement between theory and experimental data is excellent. PMID:27603017

  8. Tailoring the Blast Exposure Conditions in the Shock Tube for Generating Pure, Primary Shock Waves: The End Plate Facilitates Elimination of Secondary Loading of the Specimen.

    PubMed

    Kuriakose, Matthew; Skotak, Maciej; Misistia, Anthony; Kahali, Sudeepto; Sundaramurthy, Aravind; Chandra, Namas

    2016-01-01

    The end plate mounted at the mouth of the shock tube is a versatile and effective implement to control and mitigate the end effects. We have performed a series of measurements of incident shock wave velocities and overpressures followed by quantification of impulse values (integral of pressure in time domain) for four different end plate configurations (0.625, 2, 4 inches, and an open end). Shock wave characteristics were monitored by high response rate pressure sensors allocated in six positions along the length of 6 meters long 229 mm square cross section shock tube. Tests were performed at three shock wave intensities, which was controlled by varying the Mylar membrane thickness (0.02, 0.04 and 0.06 inch). The end reflector plate installed at the exit of the shock tube allows precise control over the intensity of reflected waves penetrating into the shock tube. At the optimized distance of the tube to end plate gap the secondary waves were entirely eliminated from the test section, which was confirmed by pressure sensor at T4 location. This is pronounced finding for implementation of pure primary blast wave animal model. These data also suggest only deep in the shock tube experimental conditions allow exposure to a single shock wave free of artifacts. Our results provide detailed insight into spatiotemporal dynamics of shock waves with Friedlander waveform generated using helium as a driver gas and propagating in the air inside medium sized tube. Diffusion of driver gas (helium) inside the shock tube was responsible for velocity increase of reflected shock waves. Numerical simulations combined with experimental data suggest the shock wave attenuation mechanism is simply the expansion of the internal pressure. In the absence of any other postulated shock wave decay mechanisms, which were not implemented in the model the agreement between theory and experimental data is excellent.

  9. Power break off in a bulb turbine: wall pressure sensor investigation

    NASA Astrophysics Data System (ADS)

    Duquesne, P.; Maciel, Y.; Aeschlimann, V.; Ciocan, G. D.; Deschênes, C.

    2014-03-01

    A measurement campaign using unsteady wall pressure sensors on a bulb turbine draft tube was performed over the power and efficiency break off range of a N11 curve. This study is part of the BulbT project, undertaken by the Consortium on hydraulic machines and the LAMH (Hydraulic Machine Laboratory of Laval University). The chosen operating points include the best efficiency point for a high runner blade angle and a high N11. Three other points, with the same N11, have been selected in the break off zone of the efficiency curve. Flow conditions have been set using the guide vanes while the runner blade angle remained constant. The pressure sensors were developed from small piezoresistive chips with high frequency response. The calibration gave an instrumental error lower than 0.3% of the measurement range. The unsteady wall pressure was measured simultaneously at 13 locations inside the first part of the draft tube, which is conical, and at 16 locations in the circular to rectangular transition part just downstream. It was also measured at 11 locations along a streamwise line path at the bottom left part of the draft tube, where flow separation occurs, covering the whole streamwise extent of the draft tube. For seven radial-azimuthal planes, four sensors were distributed azimuthally. As confirmed by tuft visualizations, the break off phenomenon is correlated to the presence of flow separation inside the diffuser at the wall. The break off is linked to the appearance of a large recirculation in the draft tube. The efficiency drop increases with the size of the separated region. Analysis of the draft tube pressure coefficients confirms that the break off is related to diffuser losses. The streamwise evolution of the mean pressure coefficient is analyzed for the different operating conditions. An azimuthal dissymmetry of the mean pressure produced by the separation is detected. The pressure signals have been analyzed and used to track the separation zone depending on the operating conditions. Spectral analysis of these signals reveals a low frequency unsteadiness generated by the flow separation.

  10. Waveguide Calibrator for Multi-Element Probe Calibration

    NASA Technical Reports Server (NTRS)

    Sommerfeldt, Scott D.; Blotter, Jonathan D.

    2007-01-01

    A calibrator, referred to as the spider design, can be used to calibrate probes incorporating multiple acoustic sensing elements. The application is an acoustic energy density probe, although the calibrator can be used for other types of acoustic probes. The calibrator relies on the use of acoustic waveguide technology to produce the same acoustic field at each of the sensing elements. As a result, the sensing elements can be separated from each other, but still calibrated through use of the acoustic waveguides. Standard calibration techniques involve placement of an individual microphone into a small cavity with a known, uniform pressure to perform the calibration. If a cavity is manufactured with sufficient size to insert the energy density probe, it has been found that a uniform pressure field can only be created at very low frequencies, due to the size of the probe. The size of the energy density probe prevents one from having the same pressure at each microphone in a cavity, due to the wave effects. The "spider" design probe is effective in calibrating multiple microphones separated from each other. The spider design ensures that the same wave effects exist for each microphone, each with an indivdual sound path. The calibrator s speaker is mounted at one end of a 14-cm-long and 4.1-cm diameter small plane-wave tube. This length was chosen so that the first evanescent cross mode of the plane-wave tube would be attenuated by about 90 dB, thus leaving just the plane wave at the termination plane of the tube. The tube terminates with a small, acrylic plate with five holes placed symmetrically about the axis of the speaker. Four ports are included for the four microphones on the probe. The fifth port is included for the pre-calibrated reference microphone. The ports in the acrylic plate are in turn connected to the probe sensing elements via flexible PVC tubes. These five tubes are the same length, so the acoustic wave effects are the same in each tube. The flexible nature of the tubes allows them to be positioned so that each tube terminates at one of the microphones of the energy density probe, which is mounted in the acrylic structure, or the calibrated reference microphone. Tests performed verify that the pressure did not vary due to bends in the tubes. The results of these tests indicate that the average sound pressure level in the tubes varied by only 0.03 dB as the tubes were bent to various angles. The current calibrator design is effective up to a frequency of approximately 4.5 kHz. This upper design frequency is largely due to the diameter of the plane-wave tubes.

  11. An Illustration of the Bernoulli Effect With a Rubber Tube

    ERIC Educational Resources Information Center

    Hanson, M. J.

    1973-01-01

    Describes a simple method of demonstrating the Bernoulli effect, by spinning a length of rubber tubing around one's head. A manometer attached to the stationary end of the tube indicates a reduction in pressure. (JR)

  12. Root cause analysis of oxide scale forming and shedding in high temperature reheater of a 200MW super high pressure boiler

    NASA Astrophysics Data System (ADS)

    Bo, Jiang; Hao, Weidong; Hu, Zhihong; Liu, Fuguo

    2015-12-01

    In order to solve the problem of over temperature tube-burst caused by oxide scale shedding and blocking tubes of high temperature reheater of a 200MW super high pressure power plant boiler, this paper expounds the mechanism of scale forming and shedding, and analyzes the probable causes of the tube-burst failure. The results show that the root cause of scale forming is that greater steam extraction flow after reforming of the second extraction leads to less steam flow into reheater, which causes over temperature to some of the heated tubes; and the root cause of scale shedding is that long term operation in AGC-R mode brings about great fluctuations of unit load, steam temperature and pressure, accelerating scale shedding. In conclusion, preventive measures are drawn up considering the operation mode of the unit.

  13. Method for automatically scramming a nuclear reactor

    DOEpatents

    Ougouag, Abderrafi M.; Schultz, Richard R.; Terry, William K.

    2005-12-27

    An automatically scramming nuclear reactor system. One embodiment comprises a core having a coolant inlet end and a coolant outlet end. A cooling system operatively associated with the core provides coolant to the coolant inlet end and removes heated coolant from the coolant outlet end, thus maintaining a pressure differential therebetween during a normal operating condition of the nuclear reactor system. A guide tube is positioned within the core with a first end of the guide tube in fluid communication with the coolant inlet end of the core, and a second end of the guide tube in fluid communication with the coolant outlet end of the core. A control element is positioned within the guide tube and is movable therein between upper and lower positions, and automatically falls under the action of gravity to the lower position when the pressure differential drops below a safe pressure differential.

  14. Design of the glass pulse-tube cryocooler

    NASA Astrophysics Data System (ADS)

    Jiang, Z.; Bernhardt, C.; Pfotenhauer, J. M.

    2017-12-01

    With the purpose of generating the curiosity of the public, a pulse-tube cryocooler with regenerator, pulse-tube, inertance tube and reservoir made of glass has been designed constructed and operated. The dimensions of the glass regenerator have been determined using REGEN3.3 [1] from given parameters of the conductive porous medium inside of the regenerator and a 150K target cooling temperature at the cold head. The geometry of the glass pulse-tube and glass inertance tube has been fixed using an approximate design method [2], and the entire system parameters checked using SAGE [3]. The thickness of each glass component is based on a charge pressure of around 7 bar and a pressure ratio of about 1.35. The dimensions of the after-cooler are calculated using ISOHX [4] assuming a gas temperature of 300 K at the inlet of the regenerator.

  15. Transient Behavior of Lumped-Constant Systems for Sensing Gas Pressures

    NASA Technical Reports Server (NTRS)

    Delio, Gene J; Schwent, Glennon V; Cesaro, Richard S

    1949-01-01

    The development of theoretical equations describing the behavior of a lumped-constant pressure-sensing system under transient operation Is presented with experimental data that show agreement with the equations. A pressure-sensing system 'consisting of a tube terminating in a reservoir is investigated for the transient relation between a presSure disturbance at the open end of the tube and the pressure response in the reservoir. Design parameters are presented that can be adjusted to achieve a desired performance fran such a system when the system is considered as a transfer member of a control loop.

  16. A new sliding joint to accommodate recoil of a free-piston-driven expansion tube facility

    NASA Astrophysics Data System (ADS)

    Gildfind, D. E.; Morgan, R. G.

    2016-11-01

    This paper describes a new device to decouple free-piston driver recoil and its associated mechanical vibration from the acceleration tube and test section of The University of Queensland's X3 expansion tube. A sliding joint is introduced to the acceleration tube which axially decouples the facility at this station. When the facility is fired, the upstream section of the facility, which includes the free-piston driver, can recoil upstream freely. The downstream acceleration tube remains stationary. This arrangement provides two important benefits. Firstly, it eliminates nozzle movement relative to the test section before and during the experiment. This has benefits in terms of experimental setup and alignment. Secondly, it prevents transmission of mechanical disturbances from the free-piston driver to the acceleration tube, thereby eliminating mechanically-induced transducer noise in the sensitive pressure transducers installed in this low-pressure tube. This paper details the new design, and presents experimental confirmation of its performance.

  17. Numerical and experimental research on pentagonal cross-section of the averaging Pitot tube

    NASA Astrophysics Data System (ADS)

    Zhang, Jili; Li, Wei; Liang, Ruobing; Zhao, Tianyi; Liu, Yacheng; Liu, Mingsheng

    2017-07-01

    Averaging Pitot tubes have been widely used in many fields because of their simple structure and stable performance. This paper introduces a new shape of the cross-section of an averaging Pitot tube. Firstly, the structure of the averaging Pitot tube and the distribution of pressure taps are given. Then, a mathematical model of the airflow around it is formulated. After that, a series of numerical simulations are carried out to optimize the geometry of the tube. The distribution of the streamline and pressures around the tube are given. To test its performance, a test platform was constructed in accordance with the relevant national standards and is described in this paper. Curves are provided, linking the values of flow coefficient with the values of Reynolds number. With a maximum deviation of only  ±3%, the results of the flow coefficient obtained from the numerical simulations were in agreement with those obtained from experimental methods. The proposed tube has a stable flow coefficient and favorable metrological characteristics.

  18. Optical study on thermal radiation energy of diesel spray combustion in a shock tube

    NASA Astrophysics Data System (ADS)

    Tsuboi, T.; Nagaya, K.; Ishii, K.

    . A ``tailored'' interface shock tube was used to measure the thermal energy radiated from diesel-spray combustion. Experiments were performed in a steel shock tube with a seven m long low-pressure section filled with air and a six m long high-pressure section. Pre-compressed fuel was injected through a throttling nozzle into air behind a reflected shock wave. Monochromatic emissive powers and emissive powers of the whole IR-wavelengths were followed with IR-detectors set along the central axis of the tube. Time-dependent-radii, where soot particles radiate, were also determined. Results were : (1) the tailored interface shock tube could be applied to a study of diesel-spray combustion. (2) thermal radiation energy could be described well from the ignition delay of the fuel spray.

  19. Numerical Simulation and Validation of a High Head Model Francis Turbine at Part Load Operating Condition

    NASA Astrophysics Data System (ADS)

    Goyal, Rahul; Trivedi, Chirag; Kumar Gandhi, Bhupendra; Cervantes, Michel J.

    2017-07-01

    Hydraulic turbines are operated over an extended operating range to meet the real time electricity demand. Turbines operated at part load have flow parameters not matching the designed ones. This results in unstable flow conditions in the runner and draft tube developing low frequency and high amplitude pressure pulsations. The unsteady pressure pulsations affect the dynamic stability of the turbine and cause additional fatigue. The work presented in this paper discusses the flow field investigation of a high head model Francis turbine at part load: 50% of the rated load. Numerical simulation of the complete turbine has been performed. Unsteady pressure pulsations in the vaneless space, runner, and draft tube are investigated and validated with available experimental data. Detailed analysis of the rotor stator interaction and draft tube flow field are performed and discussed. The analysis shows the presence of a rotating vortex rope in the draft tube at the frequency of 0.3 times of the runner rotational frequency. The frequency of the vortex rope precession, which causes severe fluctuations and vibrations in the draft tube, is predicted within 3.9% of the experimental measured value. The vortex rope results pressure pulsations propagating in the system whose frequency is also perceive in the runner and upstream the runner.

  20. [Postoperative Follow-Up of Glaucoma Drainage Devices].

    PubMed

    Dietlein, T S; Neugebauer, A; Fricke, J; Lappas, A; Rosentreter, A

    2016-05-01

    There is an increasing trend towards using glaucoma drainage implants. The postoperative management of such devices depends on their technical characteristics and specific complications. The Baerveldt glaucoma implant with its larger surface area has been shown to lower mean intraocular pressure more effectively than the Ahmed-FP7 implant. As a non-valve implant, however, it has been associated with a higher rate of severe complications, particularly ocular hypotension. Moreover, glaucoma implants may induce diplopia if they interfere with extraocular muscles. Topical treatment with antibiotics and steroids is necessary in cases of intraocular inflammation. In refractory cases, the tube may even have to be removed. Surgical reposition of the tube may be indicated when it is severely dislocated. Increased intraocular pressure is primarily treated by pressure-lowering medications during postoperative follow-up. If topical glaucoma medication is insufficient to control increases in intraocular pressure due to encapsulation, a second implant may be considered or the capsule surrounding the implant may be excised to reduce outflow resistance or additional cyclodestructive procedures can be performed. Chronic hypotension may be treated with tube ligation or occlusion. Severe corneal oedema may require lamellar keratoplasty. Conjunctival erosions with tube exposure or tube retractions also require surgical correction. Georg Thieme Verlag KG Stuttgart · New York.

  1. A program for calculating expansion-tube flow quantities for real-gas mixtures and comparison with experimental results

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III

    1972-01-01

    A computer program written in FORTRAN 4 language is presented which determines expansion-tube flow quantities for real test gases CO2 N2, O2, Ar, He, and H2, or mixtures of these gases, in thermochemical equilibrium. The effects of dissociation and first and second ionization are included. Flow quantities behind the incident shock into the quiescent test gas are determined from the pressure and temperature of the quiescent test gas in conjunction with: (1) incident-shock velocity, (2) static pressure immediately behind the incident shock, or (3) pressure and temperature of the driver gas (imperfect hydrogen or helium). The effect of the possible existence of a shock reflection at the secondary diaphragm of the expansion tube is included. Expansion-tube test-section flow conditions are obtained by performing an isentropic unsteady expansion from the conditions behind the incident shock or reflected shock to either the test-region velocity or the static pressure. Both a thermochemical-equilibrium expansion and a frozen expansion are included. Flow conditions immediately behind the bow shock of a model positioned at the test section are also determined. Results from the program are compared with preliminary experimental data obtained in the Langley 6-inch expansion tube.

  2. Gas slug ascent through changes in conduit diameter: Laboratory insights into a volcano-seismic source process in low-viscosity magmas

    USGS Publications Warehouse

    James, M.R.; Lane, S.J.; Chouet, B.A.

    2006-01-01

    Seismic signals generated during the flow and degassing of low-viscosity magmas include long-period (LP) and very-long-period (VLP) events, whose sources are often attributed to dynamic fluid processes within the conduit. We present the results of laboratory experiments designed to investigate whether the passage of a gas slug through regions of changing conduit diameter could act as a suitable source mechanism. A vertical, liquid-filled glass tube featuring a concentric diameter change was used to provide canonical insights into potentially deep or shallow seismic sources. As gas slugs ascend the tube, we observe systematic pressure changes varying with slug size, liquid depth, tube diameter, and liquid viscosity. Gas slugs undergoing an abrupt flow pattern change upon entering a section of significantly increased tube diameter induce a transient pressure decrease in and above the flare and an associated pressure increase below it, which stimulates acoustic and inertial resonant oscillations. When the liquid flow is not dominantly controlled by viscosity, net vertical forces on the apparatus are also detected. The net force is a function of the magnitude of the pressure transients generated and the tube geometry, which dictates where, and hence when, the traveling pressure pulses can couple into the tube. In contrast to interpretations of related volcano-seismic data, where a single downward force is assumed to result from an upward acceleration of the center of mass in the conduit, our experiments suggest that significant downward forces can result from the rapid deceleration of relatively small volumes of downward-moving liquid. Copyright 2006 by the American Geophysical Union.

  3. 30 CFR 250.617 - Tubing and wellhead equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-workover operations with the tree removed: (a) No tubing string shall be placed in service or continue to... the tree, you must: (1) Equip wells to monitor for casing pressure according to the following chart... surface casing head, a surface tubing head, a surface tubing hanger, and a surface christmas tree. (2...

  4. Tube failures in moisture separator-reheater tube bundles due to restrained thermal expansion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heilker, W.J.; Cassell, D.S.

    1983-01-01

    In a nuclear power plant, moisture separator-reheater components (MSRs) are used to dry and superheat the exhaust steam from the high pressure turbine before admitting this steam to the low pressure turbines. MSRs have experienced numerous problems which have caused loss of plant thermal efficiency, poor unit availability and high maintenance costs. The most serious problem has been the progressive failure of the U-tubes, which has necessitated replacement of MSR tube bundles at several plants. This paper presents an explanation of the failure mode and identifies critical operational and geometric parameters as to their respective roles in the process. Detailedmore » thermal-hydraulic analytic modeling enables the calculation of tube wall temperatures along the length of each tube for selected power levels. These temperature data are input to finite element models of the tube bundle which yield interactive displacements, rotations and stresses. The results of these studies provide the rational basis for the tube failure mechanism, which is supported by data acquired from inspection of in-service MSRs.« less

  5. Texture and hydride orientation relationship of Zircaloy-4 fuel clad tube during its fabrication for pressurized heavy water reactors

    NASA Astrophysics Data System (ADS)

    Vaibhaw, Kumar; Rao, S. V. R.; Jha, S. K.; Saibaba, N.; Jayaraj, R. N.

    2008-12-01

    Zircaloy-4 material is used for cladding tube in pressurized heavy water reactors (PHWRs) of 220 MWe and 540 MWe capacity in India. These tubes are fabricated by using various combinations of thermo-mechanical processes to achieve desired mechanical and corrosion properties. Cladding tube develops crystallographic texture during its fabrication, which has significant influence on its in-reactor performance. Due to radiolytic decomposition of water Zircaloy-4 picks-up hydrogen. This hydrogen in excess of its maximum solubility in reactor operating condition (˜300 °C), precipitates as zirconium hydrides causing embrittlement of cladding tube. Hydride orientation in the radial direction of the tube limits the service life and lowers the fuel burn-up in reactor. The orientation of the hydride primarily depends on texture developed during fabrication. A correlation between hydride orientation ( F n) with the texture in the tube during its fabrication has been developed using a second order polynomial. The present work is aimed at quantification and correlation of texture evolved in Zircaloy-4 cladding tube using Kearn's f-parameter during its fabrication process.

  6. Safe Distances From a High-Energy Capacitor Bank for Ear and Lung Protection

    DTIC Science & Technology

    2014-06-01

    switching network or device such as a Silicon Carbide Gate Turn-Off Thyristor (SGTO), Pulse Forming Network (PFN), Gas Tube, Traveling Wave Tube...increase in pressure produces an imbalance of pressure in the body and causes injury. As an example, the eardrum membrane may break if the outside

  7. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  8. 30 CFR 250.517 - Tubing and wellhead equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pressure integrity and is otherwise suitable for its intended use. (b) In the event of prolonged operations... Manager. (c) When the tree is installed, you must equip wells to monitor for casing pressure according to... platform wells, the wellhead, all annuli (A, B, C, D, etc., annuli). (2) subsea wells, the tubing head, the...

  9. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  10. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  11. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  12. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  13. Leakage of fluid around endotracheal tube cuffs: a cadaver study

    PubMed Central

    Lucius, Ralph; Ewald, Kristian

    2013-01-01

    Background The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. Methods Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülke & Mayr GmbH, Norderstedt, Germany]) was applied for thirty seconds in the mouth. During the trial, leakage of the cuffs was examined. Results The sealing between the tracheal cuff and tracheal wall was leakage-proof for all tested intracuff pressures and all tested antiseptic rinses. However, approximately 5.6 ml and 1.8 ml leaked into the esophagus and remained as a cuff-puddle, respectively. Conclusions The sealing between an endotracheal tube cuff with an intracuff pressure of 30 cmH2O and the tracheal wall is leakage-proof during oral care with antiseptic rinsing. An increase of intracuff pressure to 100 cmH2O does not appear to be required. PMID:24363847

  14. Numerical simulations of the flow in the HYPULSE expansion tube

    NASA Technical Reports Server (NTRS)

    Wilson, Gregory J.; Sussman, Myles A.; Bakos, Robert J.

    1995-01-01

    Axisymmetric numerical simulations with finite-rate chemistry are presented for two operating conditions in the HYPULSE expansion tube. The operating gas for these two cases is nitrogen and the computations are compared to experimental data. One test condition is at a total enthalpy of 15.2 MJ/Kg and a relatively low static pressure of 2 kPa. This case is characterized by a laminar boundary layer and significant chemical nonequilibrium in the acceleration gas. The second test condition is at a total enthalpy of 10.2 MJ/Kg and a static pressure of 38 kPa and is characterized by a turbulent boundary layer. For both cases, the time-varying test gas pressure predicted by the simulations is in good agreement with experimental data. The computations are also found to be in good agreement with Mirels' correlations for shock tube flow. It is shown that the nonuniformity of the test gas observed in the HYPULSE expansion tube is strongly linked to the boundary layer thickness. The turbulent flow investigated has a larger boundary layer and greater test gas nonuniformity. In order to investigate possibilities of improving expansion tube flow quality by reducing the boundary layer thickness, parametric studies showing the effect of density and turbulent transition point on the test conditions are also presented. Although an increase in the expansion tube operating pressure level would reduce the boundary layer thickness, the simulations indicate that the reduction would be less than what is predicted by flat plate boundary layer correlations.

  15. Qualification of oil-based tracer particles for heated Ludwieg tubes

    NASA Astrophysics Data System (ADS)

    Casper, Marcus; Stephan, Sören; Scholz, Peter; Radespiel, Rolf

    2014-06-01

    The generation, insertion, pressurization and use of oil-based tracer particles is qualified for the application in heated flow facilities, typically hypersonic facilities such as Ludwieg tubes. The operative challenges are to ensure a sub-critical amount of seeding material in the heated part, to qualify the methods that are used to generate the seeding, pressurize it to storage tube pressure, as well as to test specific oil types. The mass of the seeding material is held below the lower explosion limit such that operation is safe. The basis for the tracers is qualified in off-situ particle size measurements. In the main part different methods and operational procedures are tested with respect to their ability to generate a suitable amount of seeding in the test section. For the best method the relaxation time of the tracers is qualified by the oblique shock wave test. The results show that the use of a special temperature resistant lubricant oil "Plantfluid" is feasible under the conditions of a Mach-6 Ludwieg tube with heated storage tube. The method gives high-quality tracers with high seeding densities. Although the experimental results of the oblique shock wave test differ from theoretical predictions of relaxation time, still the relaxation time of 3.2 μs under the more dense tunnel conditions with 18 bar storage tube pressure is low enough to allow the use of the seeding for meaningful particle image velocimetry studies.

  16. Normal stress effects on Knudsen flow

    NASA Astrophysics Data System (ADS)

    Eu, Byung Chan

    2018-01-01

    Normal stress effects are investigated on tube flow of a single-component non-Newtonian fluid under a constant pressure gradient in a constant temperature field. The generalized hydrodynamic equations are employed, which are consistent with the laws of thermodynamics. In the cylindrical tube flow configuration, the solutions of generalized hydrodynamic equations are exactly solvable and the flow velocity is obtained in a simple one-dimensional integral quadrature. Unlike the case of flow in the absence of normal stresses, the flow develops an anomaly in that the flow in the boundary layer becomes stagnant and the thickness of such a stagnant velocity boundary layer depends on the pressure gradient, the aspect ratio of the radius to the length of the tube, and the pressure (or density and temperature) at the entrance of the tube. The volume flow rate formula through the tube is derived for the flow. It generalizes the Knudsen flow rate formula to the case of a non-Newtonian stress tensor in the presence of normal stress differences. It also reduces to the Navier-Stokes theory formula in the low shear rate limit near equilibrium.

  17. Effect of Detonation through a Turbine Stage

    NASA Technical Reports Server (NTRS)

    Ellis, Matthew T.

    2004-01-01

    Pulse detonation engines (PDE) have been investigated as a more efficient means of propulsion due to its constant volume combustion rather than the more often used constant pressure combustion of other propulsion systems. It has been proposed that a hybrid PDE-gas turbine engine would be a feasible means of improving the efficiency of the typical constant pressure combustion gas turbine cycle. In this proposed system, multiple pulse detonation tubes would replace the conventional combustor. Also, some of the compressor stages may be removed due to the pressure rise gained across the detonation wave. The benefits of higher thermal efficiency and reduced compressor size may come at a cost. The first question that arises is the unsteadiness in the flow created by the pulse detonation tubes. A constant pressure combustor has the advantage of supplying a steady and large mass flow rate. The use of the pulse detonation tubes will create an unsteady mass flow which will have currently unknown effects on the turbine located downstream of the combustor. Using multiple pulse detonation tubes will hopefully improve the unsteadiness. The interaction between the turbine and the shock waves exiting the tubes will also have an unknown effect. Noise levels are also a concern with this hybrid system. These unknown effects are being investigated using TURBO, an unsteady turbomachinery flow simulation code developed at Mississippi State University. A baseline case corresponding to a system using a constant pressure combustor with the same mass flow rate achieved with the pulse detonation hybrid system will be investigated first.

  18. Probable causes of damage of heat-exchange tubes of low-pressure-exchanges of PND-3 type and repair methods

    NASA Astrophysics Data System (ADS)

    Trifonov, N. N.; Esin, S. B.; Nikolaenkova, E. K.; Sukhorukov, Yu. G.; Svyatkin, F. A.; Sintsova, T. G.; Modestov, V. S.

    2017-08-01

    The structures of low-pressure heaters (LPH), which are installed at nuclear power plants with the K-1000-60/1500 type turbine plants are considered. It was revealed that only the PND-3 type low-pressure heaters have the damages of the heat exchange tubes. For a short operation life, the number of the damaged heat-exchange tubes of PND-3 is approximately 50 pcs for Kalinin NPP and 100-150 pcs for Balakovo NPP. The low-pressure heaters were manufactured at AO Ural Plant of Chemical Machine-Building "Uralkhimmash," OAO Taganrog Boiler-Making Works "Krasny Kotelshchik," and Vitkovice Machinery Group, but the damage nature of the heat-exchange tubes is identical for all PND-3. The damages occur in the place of passage of the heat exchange tubes through the first, the second, and the third partitions over the lower tube plate (the first path of the turbine condensate). Hydraulic shocks can be one of the possible causes of the damage of the heat-exchange tubes of PND-3. The analysis of the average thermal and dynamic loads of the tube systems of PND-1-PND-4 revealed that PND-3 by the thermal power are loaded 1.4-1.6 times and by the dynamic effects are loaded 1.8-2.0 times more than the remaining LPHs. Another possible cause of damage can be the cascaded drain of the separate into PND-4 and then through the drainage heat exchange into PND-3. An additional factor can be the structure of the condensate drainage unit. The advanced system of the heating steam flow and pumping scheme of the separate drain using the existing drainage pumps of PND-3 for K-1000-60/1500 turbine plants for Balakovo and Kalinin NPPs were proposed. The considered decisions make it possible to reduce the flow rate of the heating steam condensate from PND-3 into PND-4 and the speed of the heating steam in the tube space of PND-3 and eliminate the occurrence of hydraulic shocks and damages of the heat exchanger tubes.

  19. Impulse generation by detonation tubes

    NASA Astrophysics Data System (ADS)

    Cooper, Marcia Ann

    Impulse generation with gaseous detonation requires conversion of chemical energy into mechanical energy. This conversion process is well understood in rocket engines where the high pressure combustion products expand through a nozzle generating high velocity exhaust gases. The propulsion community is now focusing on advanced concepts that utilize non-traditional forms of combustion like detonation. Such a device is called a pulse detonation engine in which laboratory tests have proven that thrust can be achieved through continuous cyclic operation. Because of poor performance of straight detonation tubes compared to conventional propulsion systems and the success of using nozzles on rocket engines, the effect of nozzles on detonation tubes is being investigated. Although previous studies of detonation tube nozzles have suggested substantial benefits, up to now there has been no systematic investigations over a range of operating conditions and nozzle configurations. As a result, no models predicting the impulse when nozzles are used exist. This lack of data has severely limited the development and evaluation of models and simulations of nozzles on pulse detonation engines. The first experimental investigation measuring impulse by gaseous detonation in plain tubes and tubes with nozzles operating in varying environment pressures is presented. Converging, diverging, and converging-diverging nozzles were tested to determine the effect of divergence angle, nozzle length, and volumetric fill fraction on impulse. The largest increases in specific impulse, 72% at an environment pressure of 100 kPa and 43% at an environment pressure of 1.4 kPa, were measured with the largest diverging nozzle tested that had a 12° half angle and was 0.6 m long. Two regimes of nozzle operation that depend on the environment pressure are responsible for these increases and were first observed from these data. To augment this experimental investigation, all data in the literature regarding partially filled detonation tubes was compiled and analyzed with models investigating concepts of energy conservation and unsteady gas dynamics. A model to predict the specific impulse was developed for partially filled tubes. The role of finite chemical kinetics in detonation products was examined through numerical simulations of the flow in nonsteady expansion waves.

  20. Using wave intensity analysis to determine local reflection coefficient in flexible tubes.

    PubMed

    Li, Ye; Parker, Kim H; Khir, Ashraf W

    2016-09-06

    It has been shown that reflected waves affect the shape and magnitude of the arterial pressure waveform, and that reflected waves have physiological and clinical prognostic values. In general the reflection coefficient is defined as the ratio of the energy of the reflected to the incident wave. Since pressure has the units of energy per unit volume, arterial reflection coefficient are traditionally defined as the ratio of reflected to the incident pressure. We demonstrate that this approach maybe prone to inaccuracies when applied locally. One of the main objectives of this work is to examine the possibility of using wave intensity, which has units of energy flux per unit area, to determine the reflection coefficient. We used an in vitro experimental setting with a single inlet tube joined to a second tube with different properties to form a single reflection site. The second tube was long enough to ensure that reflections from its outlet did not obscure the interactions of the initial wave. We generated an approximately half sinusoidal wave at the inlet of the tube and took measurements of pressure and flow along the tube. We calculated the reflection coefficient using wave intensity (R dI and R dI 0.5 ) and wave energy (R I and R I 0.5 ) as well as the measured pressure (R dP ) and compared these results with the reflection coefficient calculated theoretically based on the mechanical properties of the tubes. The experimental results show that the reflection coefficients determined by all the techniques we studied increased or decreased with distance from the reflection site, depending on the type of reflection. In our experiments, R dP , R dI 0.5 and R I 0.5 are the most reliable parameters to measure the mean reflection coefficient, whilst R dI and R I provide the best measure of the local reflection coefficient, closest to the reflection site. Additional work with bifurcations, tapered tubes and in vivo experiments are needed to further understand, validate the method and assess its potential clinical use. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Experimental Investigation of Reynolds Number Effects on Test Quality in a Hypersonic Expansion Tube

    NASA Astrophysics Data System (ADS)

    Rossmann, Tobias; Devin, Alyssa; Shi, Wen; Verhoog, Charles

    2017-11-01

    Reynolds number effects on test time and the temporal and spatial flow quality in a hypersonic expansion tube are explored using high-speed pressure, infrared optical, and Schlieren imaging measurements. Boundary layer models for shock tube flows are fairly well established to assist in the determination of test time and flow dimensions at typical high enthalpy test conditions. However, the application of these models needs to be more fully explored due to the unsteady expansion of turbulent boundary layers and contact regions separating dissimilar gasses present in expansion tube flows. Additionally, expansion tubes rely on the development of a steady jet with a large enough core-flow region at the exit of the acceleration tube to create a constant velocity region inside of the test section. High-speed measurements of pressure and Mach number at several locations within the expansion tube allow for the determination of an experimental x-t diagram. The comparison of the experimentally determined x-t diagram to theoretical highlights the Reynolds number dependent effects on expansion tube. Additionally, spatially resolved measurements of the Reynolds number dependent, steady core-flow in the expansion tube viewing section are shown. NSF MRI CBET #1531475, Lafayette College, McCutcheon Foundation.

  2. METHOD OF CONDUCTING A PERSON BETWEEN A SAFE REGION AND A DANGEROUS REGION

    DOEpatents

    Moulthrop, H.A.

    1957-11-12

    This invention relates to a method for conducting a person between a safe region and a dangerous or con taminated region so that he may work in the dangerous region without risk to himself or the hinderance of an attached tube, and without danger of contaminating the safe region. A safely suit in which a person is to work is connected by a thermoplastic tube, turned partially inside out, to a hole in the wall separating the dangerous region. The tube is sealed by pressure and separated into two parts at the seal, whereupon the person in the suit may move around freely in the dangerous area. When the person desires to exit the dangerous region, the parts of the tube are resealed, removing a portion of the tube at the seal, and the person leaves the hole whcre he entered, seals the tube to close the hole, and cuts his suit free from the tube. Bands of masking tape inside and outside of the tube at predetermined points simplify the pressure sealing of the tube at the desired points. This patent provides a simple, safe and economical method of freely working in a dangerous region.

  3. High enthalpy, hypervelocity flows of air and argon in an expansion tube

    NASA Technical Reports Server (NTRS)

    Neely, A. J; Stalker, R. J.; Paull, A.

    1991-01-01

    An expansion tube with a free piston driver has been used to generate quasi-steady hypersonic flows in argon and air at flow velocities in excess of 9 km/s. Irregular test flow unsteadiness has limited the performance of previous expansion tubes, and it has been found that this can be avoided by attention to the interaction between the test gas accelerating expansion and the contact surface in the primary shock tube. Test section measurements of pitot pressure, static pressure and flat plate heat transfer are reported. An approximate analytical theory has been developed for predicting the velocities achieved in the unsteady expansion of the ionizing or dissociating test gas.

  4. Hypervelocity flows of argon produced in a free piston driven expansion tube

    NASA Technical Reports Server (NTRS)

    Neely, A. J.; Stalker, R. J.

    1992-01-01

    An expansion tube with a free piston driver has been used to generate quasi-steady hypersonic flows in argon at flow velocities in excess of 9 km/s. Irregular test flow unsteadiness has limited the performance of previous expansion tubes. Test section measurements of pitot pressure, static pressure, and flat plate heat transfer rates are used to confirm the presence of quasi-steady flow, and comparisons are made with predictions for the equilibrium flow of an ideal, ionizing, monatomic gas. The results of this work indicate that expansion tubes can be used to generate quasi-steady hypersonic flows in argon at speeds in excess of Earth orbital velocity.

  5. Shock tube studies of thermal radiation of diesel-spray combustion under a range of spray conditions

    NASA Astrophysics Data System (ADS)

    Tsuboi, T.; Kurihara, Y.; Takasaki, M.; Katoh, R.; Ishii, K.

    2007-05-01

    A tailored interface shock tube and an over-tailored interface shock tube were used to measure the thermal energy radiated during diesel-spray combustion of light oil, α-methylnaphthalene and cetane by changing the injection pressure. The ignition delay of methanol and the thermal radiation were also measured. Experiments were performed in a steel shock tube with a 7 m low-pressure section filled with air and a 6 m high-pressure section. Pre-compressed fuel was injected through a throttle nozzle into air behind a reflected shock wave. Monochromatic emissive power and the power emitted across all infrared wavelengths were measured with IR-detectors set along the central axis of the tube. Time-dependent radii where soot particles radiated were also determined, and the results were as follows. For diesel spray combustion with high injection pressures (from 10 to 80 MPa), the thermal radiation energy of light oil per injection increased with injection pressure from 10 to 30 MPa. The energy was about 2% of the heat of combustion of light oil at P inj = about 30 MPa. At injection pressure above 30 MPa the thermal radiation decreased with increasing injection pressure. This profile agreed well with the combustion duration, the flame length, the maximum amount of soot in the flame, the time-integrated soot volume and the time-integrated flame volume. The ignition delay of light oil was observed to decrease monotonically with increasing fuel injection pressure. For diesel spray combustion of methanol, the thermal radiation including that due to the gas phase was 1% of the combustion heat at maximum, and usually lower than 1%. The thermal radiation due to soot was lower than 0.05% of the combustion heat. The ignition delays were larger (about 50%) than those of light oil. However, these differences were within experimental error.

  6. Rapid and selective brain cooling method using vortex tube: A feasibility study.

    PubMed

    Bakhsheshi, Mohammad Fazel; Keenliside, Lynn; Lee, Ting-Yim

    2016-05-01

    Vortex tubes are simple mechanical devices to produce cold air from a stream of compressed air without any moving parts. The primary focus of the current study is to investigate the feasibility and efficiency of nasopharyngeal brain cooling method using a vortex tube. Experiments were conducted on 5 juvenile pigs. Nasopharygeal brain cooling was achieved by directing cooled air via a catheter in each nostril into the nasal cavities. A vortex tube was used to generate cold air using various sources of compressed air: (I) hospital medical air outlet (n = 1); (II) medical air cylinders (n = 3); and (III) scuba (diving) cylinders (n = 1). By using compressed air from a hospital medical air outlet at fixed inlet pressure of 50 PSI, maximum brain-rectal temperature gradient of -2°C was reached about 45-60 minutes by setting the flow rate of 25 L/min and temperature of -7°C at the cold air outlet. Similarly, by using medical air cylinders at fill-pressure of 2265 PSI and down regulate the inlet pressure to the vortex tube to 50 PSI, brain temperature could be reduced more rapidly by blowing -22°C ± 2°C air at a flow rate of 50 L/min; brain-body temperature gradient of -8°C was obtained about 30 minutes. Furthermore, we examined scuba cylinders as a portable source of compressed gas supply to the vortex tube. Likewise, by setting up the vortex tube to have an inlet pressure of 25 PSI and 50 L/min and -3°C at the cold air outlet, brain temperature decreased 4.5°C within 10-20 min. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush.

    PubMed

    Groth, Sylvia L; Greider, Kelsi L; Sponsel, William Eric

    2015-01-01

    To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. Case series. Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.

  8. Microphone Detects Boiler-Tube Leaks

    NASA Technical Reports Server (NTRS)

    Parthasarathy, S. P.

    1985-01-01

    Unit simple, sensitive, rugged, and reliable. Diaphragmless microphone detects leaks from small boiler tubes. Porous plug retains carbon granules in tube while allowing pressure changes to penetrate to granules. Has greater life expectancy than previous controllers and used in variety of hot corrosive atmospheres.

  9. Biaxial and Shear Testing Apparatus with Force Controls

    DTIC Science & Technology

    2006-03-30

    materials as the test specimen. (2) Description of the Prior Art [0004] It is known in the art that pressurized fabric tubes ; pressure-stabilized beams...apparatus is that these roller pins prevent any torsional load from reaching the test specimen. [0010] In Ward et al., (United States Patent No. 5,279,166...loading a specimen through pressurizing the inside surface of a cylinder is disclosed. A thin-wall tube specimen is biaxially tested for stress analysis

  10. Creep-rupture tests of internally pressurized Rene 41 tubes

    NASA Technical Reports Server (NTRS)

    Gumto, K. H.; Weiss, B.

    1972-01-01

    Weld-drawn tubes of Rene 41 with 0.935 centimeter outside diameter and 0.064 centimeter wall thickness were tested to failure at temperatures from 1117 to 1233 K and internal helium pressures from 5.5 to 12.4 meganewtons per square meter. Lifetimes ranged from 5 to 2065 hours. The creep-rupture strength of the tubes was 50 percent lower than that of unwelded, thick sheet specimens, and 20 percent lower than that of unwelded, thin sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.

  11. Kundt's Tube: An Acoustic Gas Analyzer

    ERIC Educational Resources Information Center

    Aristov, Natasha; Habekost, Gehsa; Habekost, Achim

    2011-01-01

    A Kundt tube is normally used to measure the speed of sound in gases. Therefore, from known speeds of sound, a Kundt tube can be used to identify gases and their fractions in mixtures. In these experiments, the speed of sound is determined by measuring the frequency of a standing sound wave at a fixed tube length, temperature, and pressure. This…

  12. Parametric Study of High Frequency Pulse Detonation Tubes

    NASA Technical Reports Server (NTRS)

    Cutler, Anderw D.

    2008-01-01

    This paper describes development of high frequency pulse detonation tubes similar to a small pulse detonation engine (PDE). A high-speed valve injects a charge of a mixture of fuel and air at rates of up to 1000 Hz into a constant area tube closed at one end. The reactants detonate in the tube and the products exit as a pulsed jet. High frequency pressure transducers are used to monitor the pressure fluctuations in the device and thrust is measured with a balance. The effects of injection frequency, fuel and air flow rates, tube length, and injection location are considered. Both H2 and C2H4 fuels are considered. Optimum (maximum specific thrust) fuel-air compositions and resonant frequencies are identified. Results are compared to PDE calculations. Design rules are postulated and applications to aerodynamic flow control and propulsion are discussed.

  13. Acoustic Resonance and Vortex Shedding from Tube Banks of Boiler Plant

    NASA Astrophysics Data System (ADS)

    Hamakawa, Hiromitsu; Matsue, Hiroto; Nishida, Eiichi; Fukano, Tohru

    This paper focuses on the relationship between acoustic resonance and vortex shedding from the tube banks of a boiler plant. We have built a model similar to the actual boiler plant to clarify the characteristics of acoustic resonance phenomena and vortex shedding. The model used in-line tube banks with a small tube pitch ratio. We examined the relationship between the acoustic resonance of the actual plant and that of the model, and measured the sound pressure level, acoustic pressure mode shape, spectrum of velocity fluctuation, and gap velocity. Gap velocity was defined as the mean velocity in the smallest gaps between two neighboring tubes in the transverse direction. As a result, the resonant frequencies and mode shapes of the acoustic resonances in the actual boiler plant agreed well with those in the similar model. We found many peak frequencies in the sound pressure level spectrum when acoustic resonances occurred. The typical Strouhal numbers at the onset velocity of acoustic resonances were about 0.19, 0.26 and 0.52. Periodic velocity fluctuation caused by vortex shedding was observed inside the tube banks without acoustic resonance. The Strouhal number measured for vortex shedding was 0.15. Acoustic resonances of higher-order modes were generated in this plant.

  14. Experimental investigation on heat transfer and frictional characteristics of vertical upward rifled tube in supercritical CFB boiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dong; Pan, Jie; Zhu, Xiaojing

    2011-02-15

    Water wall design is a key issue for supercritical Circulating Fluidized Bed (CFB) boiler. On account of the good heat transfer performance, rifled tube is applied in the water wall design of a 600 MW supercritical CFB boiler in China. In order to investigate the heat transfer and frictional characteristics of the rifled tube with vertical upward flow, an in-depth experiment was conducted in the range of pressure from 12 to 30 MPa, mass flux from 230 to 1200 kg/(m{sup 2} s), and inner wall heat flux from 130 to 720 kW/m{sup 2}. The wall temperature distribution and pressure dropmore » in the rifled tube were obtained in the experiment. The normal, enhanced and deteriorated heat transfer characteristics were also captured. In this paper, the effects of pressure, inner wall heat flux and mass flux on heat transfer characteristics are analyzed, the heat transfer mechanism and the frictional resistance performance are discussed, and the corresponding empirical correlations are presented. The experimental results show that the rifled tube can effectively prevent the occurrence of departure from nucleate boiling (DNB) and keep the tube wall temperature in a permissible range under the operating condition of supercritical CFB boiler. (author)« less

  15. Pediatric Tubular Pulmonary Heart Valve from Decellularized Engineered Tissue Tubes

    PubMed Central

    Reimer, Jay M.; Syedain, Zeeshan H.; Haynie, Bee H.T.; Tranquillo, Robert T.

    2015-01-01

    Pediatric patients account for a small portion of the heart valve replacements performed, but a pediatric pulmonary valve replacement with growth potential remains an unmet clinical need. Herein we report the first tubular heart valve made from two decellularized, engineered tissue tubes attached with absorbable sutures, which can meet this need, in principle. Engineered tissue tubes were fabricated by allowing ovine dermal fibroblasts to replace a sacrificial fibrin gel with an aligned, cell-produced collagenous matrix, which was subsequently decellularized. Previously, these engineered tubes became extensively recellularized following implantation into the sheep femoral artery. Thus, a tubular valve made from these tubes may be amenable to recellularization and, ideally, somatic growth. The suture line pattern generated three equi-spaced “leaflets” in the inner tube, which collapsed inward when exposed to back pressure, per tubular valve design. Valve testing was performed in a pulse duplicator system equipped with a secondary flow loop to allow for root distention. All tissue-engineered valves exhibited full leaflet opening and closing, minimal regurgitation (< 5%), and low systolic pressure gradients (< 2.5 mmHg) under pulmonary conditions. Valve performance was maintained under various trans-root pressure gradients and no tissue damage was evident after 2 million cycles of fatigue testing. PMID:26036175

  16. Oscillatory fluid flow in deformable tubes: Implications for pore-scale hydromechanics from comparing experimental observations with theoretical predictions.

    PubMed

    Kurzeja, Patrick; Steeb, Holger; Strutz, Marc A; Renner, Jörg

    2016-12-01

    Oscillatory flow of four fluids (air, water, two aqueous sodium-tungstate solutions) was excited at frequencies up to 250 Hz in tubes of two materials (steel, silicone) covering a wide range in length, diameter, and thickness. The hydrodynamical response was characterized by phase shift and amplitude ratio between pressures in an upstream (pressure excitation) and a downstream reservoir connected by the tubes. The resulting standing flow waves reflect viscosity-controlled diffusive behavior and inertia-controlled wave behavior for oscillation frequencies relatively low and high compared to Biot's critical frequency, respectively. Rigid-tube theories correspond well with the experimental results for steel tubes filled with air or water. The wave modes observed for silicone tubes filled with the rather incompressible liquids or air, however, require accounting for the solid's shear and bulk modulus to correctly predict speed of pressure propagation and deformation mode. The shear mode may be responsible for significant macroscopic attenuation in porous materials with effective frame-shear moduli lower than the bulk modulus of the pore fluid. Despite notable effects of the ratio of densities and of acoustic and shear velocity of fluid and solid, Biot's frequency remains an approximate indicator of the transition from the viscosity to the inertia controlled regime.

  17. Failure Analysis of T-38 Aircraft Burst Hydraulic Aileron Return Line

    NASA Technical Reports Server (NTRS)

    Martinez, J. E.; Figert, J. D.; Paton, R. M.; Nguyen, S. D.; Flint, A.

    2012-01-01

    During maintenance troubleshooting for fluctuating hydraulic pressures, a technician found that a right hand aileron return line, on the flight hydraulic side, was ruptured (Fig. 1, 2). This tubing is part of the Hydraulic Flight Control Aileron Return Reducer to Aileron Manifold and is suspected to be original to the T-38 Talon trainer aircraft. Ailerons are small hinged sections on the outboard portion of a wing used to generate rolling motion thereby banking the aircraft. The ailerons work by changing the effective shape of the airfoil of the outer portion of the wing [1]. The drawing, Northrop P/N 3-43033-55 (6/1960), specifies that the line is made from 0.375 inch OD, aluminum 5052-0 tubing with a 0.049 inch wall thickness. WW-T-787 requires the tube shall be seamless and uniform in quality and temper [2]. The test pressure for this line is 3000 psi, and the operational pressure for this line is estimated to be between 45 psi and 1500 psi based on dynamic loading during flight. Examination of the fracture surface found evidence of arrest bands originating on the inner diameter (Fig 3). Ductile dimples are observed on the tube fractures (Fig. 4). The etched cross-section revealed thinning and work-hardening in the burst region (Fig. 5). The wall thickness just outside the work-hardened fracture region measured 0.035". Barlow's Formula: P = 2St/D, where P is burst pressure, S is allowable stress, t is wall thickness and D is the outer diameter of tube. Using the ultimate tensile strength of 28 ksi and a measured wall thickness of 0.035 inches at burst, P = 5.2 ksi (burst pressure). Using the yield of 13 ksi (YS) for aluminum 5052-0, plastic deformation will happen at P = 2.4 ksi suggesting plastic deformation occurred at a proof pressure of 3.0 ksi. Conclusion: The burst resulted from high stress, low-cycle fatigue. Evidence of arrest bands originating on the inner diameter. Fracture is predominately shear dimples, characteristic of high load ductile fractures (Fig 6). Section wall reduction in the burst region. Plastic deformation and thinning of the out-of-specification tube wall likely happened during the initial proof testing years ago. Metallography of tubing away from rupture site confirmed tubing was seamless. Based on the tube microstructure, it is likely that the initial wall thickness was about 30 % thinner than the requirement of 0.049 inches. Fracture initiated on the ID and progressed to the OD (shear lip). The tube is made of the correct material of 5052-0 aluminum as verified using Optical Emission Spectroscopy (Table 2). The tubing hardness tested 77 HV100 (77 HRE). This hardness is slightly above the requirement for 70 HRE maximum for aluminum 5052-0 in AMS 2658C [3].

  18. 46 CFR 56.01-2 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Steel Pipe for High-Temperature Service (“ASTM A 106”), 56.60-1; (5) ASTM A 126-95, Standard... (1996), Standard Specification for Seamless Carbon Steel Boiler Tubes for High-Pressure Service (“ASTM A...-Resistance-Welded Carbon Steel Boiler and Superheater Tubes for High-Pressure Service (“ASTM A 226”), 56.60-1...

  19. Atmospheric pressure helium afterglow discharge detector for gas chromatography

    DOEpatents

    Rice, G.; D'Silva, A.P.; Fassel, V.A.

    1985-04-05

    An apparatus for providing a simple, low-frequency, electrodeless discharge system for atmospheric pressure afterglow generation. A single quartz tube through which a gas mixture is passed is extended beyond a concentric electrode positioned thereabout. A grounding rod is placed directly above the tube outlet to permit optical viewing of the discharge between the electrodes.

  20. Atmospheric pressure helium afterglow discharge detector for gas chromatography

    DOEpatents

    Rice, Gary; D'Silva, Arthur P.; Fassel, Velmer A.

    1986-05-06

    An apparatus for providing a simple, low-frequency electrodeless discharge system for atmospheric pressure afterglow generation. A single quartz tube through which a gas mixture is passed is extended beyond a concentric electrode positioned thereabout. A grounding rod is placed directly above the tube outlet to permit optical viewing of the discharge between the electrodes.

  1. Testing the Münch hypothesis of long distance phloem transport in plants.

    PubMed

    Knoblauch, Michael; Knoblauch, Jan; Mullendore, Daniel L; Savage, Jessica A; Babst, Benjamin A; Beecher, Sierra D; Dodgen, Adam C; Jensen, Kaare H; Holbrook, N Michele

    2016-06-02

    Long distance transport in plants occurs in sieve tubes of the phloem. The pressure flow hypothesis introduced by Ernst Münch in 1930 describes a mechanism of osmotically generated pressure differentials that are supposed to drive the movement of sugars and other solutes in the phloem, but this hypothesis has long faced major challenges. The key issue is whether the conductance of sieve tubes, including sieve plate pores, is sufficient to allow pressure flow. We show that with increasing distance between source and sink, sieve tube conductivity and turgor increases dramatically in Ipomoea nil. Our results provide strong support for the Münch hypothesis, while providing new tools for the investigation of one of the least understood plant tissues.

  2. Carbon nanotube vacuum gauges utilizing long, dissipative tubes

    NASA Astrophysics Data System (ADS)

    Kaul, Anupama B.; Manohara, Harish M.

    2008-04-01

    A carbon nanotube-based thermal conductivity vacuum gauge is described which utilizes 5-10 μm long diffusively contacted SWNTs for vacuum sensing. By etching the thermal SiO II beneath the tubes and minimizing heat conduction through the substrate, pressure sensitivity was extended toward higher vacuums. The pressure response of unannealed and annealed devices was compared to that of released devices. The released devices showed sensitivity to pressure as low as 1 x 10 -6 Torr. The sensitivity increased more dramatically with power for the released device compared to that of the unreleased device. Low temperature electronic transport measurements of the tubes were suggestive of a thermally activated hopping mechanism where the activation energy for hopping was calculated to be ~ 39 meV.

  3. Solar thermal power system

    DOEpatents

    Bennett, Charles L.

    2010-06-15

    A solar thermal power generator includes an inclined elongated boiler tube positioned in the focus of a solar concentrator for generating steam from water. The boiler tube is connected at one end to receive water from a pressure vessel as well as connected at an opposite end to return steam back to the vessel in a fluidic circuit arrangement that stores energy in the form of heated water in the pressure vessel. An expander, condenser, and reservoir are also connected in series to respectively produce work using the steam passed either directly (above a water line in the vessel) or indirectly (below a water line in the vessel) through the pressure vessel, condense the expanded steam, and collect the condensed water. The reservoir also supplies the collected water back to the pressure vessel at the end of a diurnal cycle when the vessel is sufficiently depressurized, so that the system is reset to repeat the cycle the following day. The circuital arrangement of the boiler tube and the pressure vessel operates to dampen flow instabilities in the boiler tube, damp out the effects of solar transients, and provide thermal energy storage which enables time shifting of power generation to better align with the higher demand for energy during peak energy usage periods.

  4. A canine model of tracheal stenosis induced by cuffed endotracheal intubation

    PubMed Central

    Su, Zhuquan; Li, Shiyue; Zhou, Ziqing; Chen, Xiaobo; Gu, Yingying; Chen, Yu; Zhong, Changhao; Zhong, Minglu; Zhong, Nanshan

    2017-01-01

    Postintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal stenosis remain not fully understood. We aimed to establish an animal model and to investigate risk factors for postintubation tracheal stenosis. Beagles were intubated with 4 sized tubes (internal diameter 6.5 to 8.0 mm) and cuff pressures of 100 to 200 mmHg for 24 hr. The status of tracheal wall was evaluated by bronchoscopic and histological examinations. The model was successfully established by cuffed endotracheal intubation using an 8.0 mm tube and an intra-cuff pressure of 200 mmHg for 24 hr. When the intra-cuff pressures were kept constant, a larger sized tube would induce a larger tracheal wall pressure and more severe injury to the tracheal wall. The degree of tracheal stenosis ranged from 78% to 91% at 2 weeks postextubation. Histological examination demonstrated submucosal infiltration of inflammatory cells, hyperplasia of granulation tissue and collapse of tracheal cartilage. In summary, a novel animal model of tracheal stenosis was established by cuffed endotracheal intubation, whose histopathological feathers are similar to those of clinical cases of postintubation tracheal stenosis. Excessive cuff pressure and over-sized tube are the risk factors for postintubation tracheal stenosis. PMID:28349955

  5. Heat Transfer and Pressure Drop in Concentric Annular Flows of Binary Inert Gas Mixtures

    NASA Technical Reports Server (NTRS)

    Reid, R. S.; Martin, J. J.; Yocum, D. J.; Stewart, E. T.

    2007-01-01

    Studies of heat transfer and pressure drop of binary inert gas mixtures flowing through smooth concentric circular annuli, tubes with fully developed velocity profiles, and constant heating rate are described. There is a general lack of agreement among the constant property heat transfer correlations for such mixtures. No inert gas mixture data exist for annular channels. The intent of this study was to develop highly accurate and benchmarked pressure drop and heat transfer correlations that can be used to size heat exchangers and cores for direct gas Brayton nuclear power plants. The inside surface of the annular channel is heated while the outer surface of the channel is insulated. Annulus ratios range 0.5 < r* < 0.83. These smooth tube data may serve as a reference to the heat transfer and pressure drop performance in annuli, tubes, and channels having helixes or spacer ribs, or other surfaces.

  6. Curved and conformal high-pressure vessel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Croteau, Paul F.; Kuczek, Andrzej E.; Zhao, Wenping

    A high-pressure vessel is provided. The high-pressure vessel may comprise a first chamber defined at least partially by a first wall, and a second chamber defined at least partially by the first wall. The first chamber and the second chamber may form a curved contour of the high-pressure vessel. A modular tank assembly is also provided, and may comprise a first mid tube having a convex geometry. The first mid tube may be defined by a first inner wall, a curved wall extending from the first inner wall, and a second inner wall extending from the curved wall. The firstmore » inner wall may be disposed at an angle relative to the second inner wall. The first mid tube may further be defined by a short curved wall opposite the curved wall and extending from the second inner wall to the first inner wall.« less

  7. Manometer Boards below the 8- by 6-Foot Supersonic Wind Tunnel

    NASA Image and Video Library

    1951-02-21

    Analysts at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory take data readings from rows of manometers in the basement of the 8- by 6-Foot Supersonic Wind Tunnel. Manometers were mercury-filled glass tubes that indicated different pressure levels in the test section. Manometers look and function very similarly to thermometers. Pressure sensing instruments were installed on the test article inside the wind tunnel or other test facility. Each test could have dozens of such instruments installed and connected to a remotely located manometer tube. The mercury inside the manometer rose and fell with the pressure levels. The dark mercury can be seen at different levels within the tubes. Since the pressure readings were dynamic, it was necessary to note the levels at given points during the test. This was done using both female computers and photography. A camera is seen on a stand to the right in this photograph.

  8. [Influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge].

    PubMed

    Huang, Ling; Xie, Chen; Zhang, Lifeng; Meng, Liying; Li, Guizheng; Li, Yang; Huang, Bing; Pan, Linghui; Tang, Zhanhong

    2017-01-01

    To discuss the influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge, and to provide some reference for the clinical work. The experiment was carried out on the model of the glass tube, which was divided into three parts. Each part of the experiment was divided into normal pressure group and high pressure group according to the different inflation pressure target value. The endotracheal tube cuff pressure was determined intermittently by using the transparent tracheal models which had a static diameter of 2 cm. The target press value of normal pressure group was 32 cmH 2 O (1 cmH 2 O = 0.098 kPa) while that of high pressure group was 40 cmH 2 O. The handheld pressure gauge was connected with the indicated cuff through a tee joint, and the pressure in the cuff in both groups was determined. The pressure loss caused by intermittent measurement of the two groups was compared. By switching the tee joint, the pressure loss through the gauge self-structure and the pressure loss when connecting and disconnecting the indicated cuff were determined to analyze the causes of pressure loss caused by intermittent measurement of pressure gauge. The pressure loss caused by intermittent measurement of high pressure group was significantly higher than that of normal pressure group (cmH 2 O: 15.10±0.43 vs. 10.19±0.45) with statistical significance (t = -24.875, P = 0.000). The pressure loss through the gauge self-structure of high pressure group was also significantly higher than that of normal pressure group (cmH 2 O: 13.91±0.48 vs. 8.77±0.53), which showed a statistics significance (t = -22.854, P = 0.000). The pressure loss when connecting and disconnecting the indicated cuff of the normal pressure and high pressure groups were (1.33±0.49) cmH 2 O and (1.23±0.55) cmH 2 O, respectively, without statistics significance (t = 0.445, P = 0.662). It was figured that the total pressure loss caused by intermittent measurement of the endotracheal intubation cuff was approximately equal to the value of the pressure loss caused by the pressure gauge self-structure and the pressure loss when the indicated cuff was connected and disconnected [normal pressure group: (10.19±0.45) cmH 2 O ≍ (8.77±0.53) cmH 2 O + (1.33±0.49) cmH 2 O, high pressure group: (15.10±0.43) cmH 2 O ≍ (13.91±0.48) cmH 2 O + (1.23±0.55) cmH 2 O]. The intermittently monitoring on endotracheal tube cuff pressure is the main cause of the pressure loss. The total pressure loss consists of the pressure leak from the cuff to the gauge and the pressure leak when connecting and disconnecting the gauge and the indicated cuff during each test. When the pressure in the cuff is increased, it will cause more pressure loss.

  9. SHEATHED TUBE AND APPARATUS AND METHOD OF PRODUCTION THEREOF

    DOEpatents

    Ohlinger, L.A.

    1959-08-18

    A tubular fuel element covered inside and out by a unitary covering tube originally about twice its length and of small enough diameter to fit snugly inside the fuel tube is described. The covering tube is then reentrantly folded back by a pressure-die mechanism over both ends of the fuel tube and againsts outside until the folded back ends of the covering tube meet where they are welded in a single seam running circumferentially around the middle of the resulting assembly.

  10. RP-1 Thermal Stability and Copper Based Materials Compatibility Study

    NASA Technical Reports Server (NTRS)

    Stiegemeier, B. R.; Meyer, M. L.; Driscoll, E.

    2005-01-01

    A series of electrically heated tube tests was performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the effect that sulfur content, test duration, and tube material play in the overall thermal stability and materials compatibility characteristics of RP-1. Scanning-electron microscopic (SEM) analysis in conjunction with energy dispersive spectroscopy (EDS) were used to characterize the condition of the tube inner wall surface and any carbon deposition or corrosion formed during these runs. Results of the parametric study indicate that tests with standard RP-1 (total sulfur -23 ppm) and pure copper tubing are characterized by a depostion/deposit shedding process producing local wall temperature swings as high as 500 F. The effect of this shedding is to keep total carbon deposition levels relatively constant for run times from 20 minutes up to 5 hours, though increasing tube pressure drops were observed in all runs. Reduction in the total sulfur content of the fuel from 23 ppm to less than 0.1 ppm resulted in the elimination of deposit shedding, local wall temperature variation, and the tube pressure drop increases that were observed in standard sulfur level RP-1 tests. The copper alloy GRCop-84, a copper alloy developed specifically for high heat flux applications, was found to exhibit higher carbon deposition levels compared to identical tests performed in pure copper tubes. Results of the study are consistent with previously published heated tube data which indicates that small changes in fuel total sulfur content can lead to significant differences in the thermal stability of kerosene type fuels and their compatibility with copper based materials. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-1.

  11. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    PubMed

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  12. Simulation of a shock tube with a small exit nozzle

    NASA Astrophysics Data System (ADS)

    Luan, Yigang; Olzmann, Matthias; Magagnato, Franco

    2018-02-01

    Shock tubes are frequently used to rapidly heat up reaction mixtures to study chemical reaction mechanisms and kinetics in the field of combustion chemistry [1]. In the present work, the flow field inside a shock tube with a small nozzle in the end plate has been investigated to support the analysis of reacting chemical mixtures with an attached mass spectrometer and to clarify whether the usual assumptions for the flow field and the related thermodynamics are fulfilled. In the present work, the details of the flow physics inside the tube and the flow out of the nozzle in the end plate have been investigated. Due to the large differences in the typical length scales and the large pressure ratios of this special device, a very strong numerical stiffness prevails during the simulation process. Second-order ROE numerical schemes have been employed to simulate the flow field inside the shock tube. The simulations were performed with the commercial code ANSYS Fluent [2]. Axial-symmetric boundary conditions are employed to reduce the consumption of CPU time. A density-based transient scheme has been used and validated in terms of accuracy and efficiency. The simulation results for pressure and density are compared with analytical solutions. Numerical results show that a density-based numerical scheme performs better when dealing with shock-tube problems [5]. The flow field near the nozzle is studied in detail, and the effects of the nozzle to pressure and temperature variations inside the tube are investigated. The results show that this special shock-tube setup can be used to study high-temperature gas-phase chemical reactions with reasonable accuracy.

  13. Orotracheal tube as a risk factor for lower respiratory tract infection: preliminary data from a randomised trial.

    PubMed

    Muzlovic, Igor; Perme, Janja; Stubljar, David

    2018-05-01

    The aim of the study was to investigate whether polyurethane (PU) endotracheal tubes, continuous measurements of cuff pressure and aspiration of the subglottic space as a bundle of parameters could reduce patients' risk for developing ventilator associated pneumonia (VAP). Two groups of patients that differed only in terms of endotracheal tubes and intubation intervention were compared. Group A was ventilated using PU tubes a with conical cuff; they also had continuous cuff pressure measurement and continuous subglottic aspiration. Group B was ventilated using PVC tubes with a cylindrical cuff; the patients underwent intermittent cuff pressure measurement and intermittent subglottic aspiration. Seven patients in group A (13.2%) and 18 in group B (36.0%) out of 103 were diagnosed with VAP. VAP patients were in general older, stayed longer in the ICU and were ventilated significantly longer compared with the patients with no VAP. Eight more patients in group B died compared with group A. Moreover, subjects in group A survived longer. Patient age, hours on mechanical ventilation, and days on an ICU were all positively associated with the occurrence of VAP. Prevention parameters in ventilation (PU cuff, conical cuff, continuous subglottic drainage and continuous cuff pressure measurement) could prevent the incidence of VAP in ICU patients.

  14. PARTIAL ECONOMIC STUDY OF STEAM COOLED HEAVY WATER MODERATED REACTORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1960-04-01

    Steam-cooled reactors are compared with CAHDU for costs of Calandria tubes, pressure tubes. heavy water moderator, heavy water reflector, fuel supply, heat exchanger, and turbine generator. A direct-cycle lightsteam-cooled heavy- water-moderated pressure-tube reactor formed the basic reactor design for the study. Two methods of steam circulation through the reactor were examined. In both cases the steam was generated outside the reactor and superheated in the reactor core. One method consisted of a series of reactor and steam generator passes. The second method consisted of the Loeffler cycle and its modifications. The fuel was assumed to be natural cylindrical UO/sub 2/more » pellets sheathed in a hypothetical material with the nuclear properties of Zircaloy, but able to function at temperatures to 900 deg F. For the conditions assumed, the longer the rod, the higher the outlet temperature and therefore the higher the efficiency. The turbine cycle efficiency was calculated on the assumption that suitable steam generators are available. As the neutron losses to the pressure tubes were significant, an economic analysis of insulated pressure tubes is included. A description of the physics program for steam-cooled reactors is included. Results indicated that power from the steam-cooled reactor would cost 1.4 mills/ kwh compared with 1.25 mills/kwh for CANDU. (M.C.G.)« less

  15. Reconstruction of an acoustic pressure field in a resonance tube by particle image velocimetry.

    PubMed

    Kuzuu, K; Hasegawa, S

    2015-11-01

    A technique for estimating an acoustic field in a resonance tube is suggested. The estimation of an acoustic field in a resonance tube is important for the development of the thermoacoustic engine, and can be conducted employing two sensors to measure pressure. While this measurement technique is known as the two-sensor method, care needs to be taken with the location of pressure sensors when conducting pressure measurements. In the present study, particle image velocimetry (PIV) is employed instead of a pressure measurement by a sensor, and two-dimensional velocity vector images are extracted as sequential data from only a one- time recording made by a video camera of PIV. The spatial velocity amplitude is obtained from those images, and a pressure distribution is calculated from velocity amplitudes at two points by extending the equations derived for the two-sensor method. By means of this method, problems relating to the locations and calibrations of multiple pressure sensors are avoided. Furthermore, to verify the accuracy of the present method, the experiments are conducted employing the conventional two-sensor method and laser Doppler velocimetry (LDV). Then, results by the proposed method are compared with those obtained with the two-sensor method and LDV.

  16. Hydraulic drill string breakdown and bleed off unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeringue, F.J. Jr.

    1987-02-17

    An apparatus is described for use within an oil well rig for decoupling a tubing string into pipe segments comprising, in combination: rotary tong means for applying an unthreading torque to a first, upper pipe segment within the tubing string; torque resisting means for securing a second, lower pipe segment within the tubing string against the unthreading torque; containing means, intermediate the rotary tong means and the torque resisting means, enclosing a threaded joint of the tubing string, adapted for containing pressurized gases, liquids, and particulates, released from the threaded joint upon the decoupling; fluid communicating means for allowing fluidmore » communication between the containing means and a receiving point adapted for receiving the pressurized gases, liquids, and particulates; means for moving the rotary tong means, the torque resisting means and the containing means between a closed, engaging position with the tubing string and an open position; and means for horizontally moving the rotary tong means, the torque resisting means and the containing means between a position adjacent the tubing string and a position away from the tubing string.« less

  17. Ultimate Temperature of Pulse Tube Cryocoolers

    NASA Technical Reports Server (NTRS)

    Kittel, Peter

    2009-01-01

    An ideal pulse tube cryocooler using an ideal gas can operate at any temperature. This is not true for real gases. The enthalpy flow resulting from the real gas effects of He-3, He-4, and their mixtures in ideal pulse tube cryocoolers puts limits on the operating temperature of pulse tube cryocoolers. The discussion of these effects follows a previous description of the real gas effects in ideal pulse tube cryocoolers and makes use of models of the thermophysical properties of He-3 and He-4. Published data is used to extend the analysis to mixtures of He-3 and He-4. The analysis was done for pressures below 2 MPa and temperatures below 2.5 K. Both gases and their mixtures show low temperature limits for pulse tube cryocoolers. These limits are in the 0.5-2.2 K range and depend on pressure and mixture. In some circumstances, even lower temperatures may be possible. Pulse tube cryocoolers using the two-fluid properties of dilute 3He in superfluid He-4 appear to have no limit.

  18. Ultimate Temperature of Pulse Tube Cryocoolers

    NASA Technical Reports Server (NTRS)

    Kittel, Peter

    2009-01-01

    An ideal pulse tube cryocooler using an ideal gas can operate at any temperature. This is not true for real gases. The enthalpy flow resulting from the real gas effects of 3He, 4He, and their mixtures in ideal pulse tube cryocoolers puts limits on the operating temperature of pulse tube cryocoolers. The discussion of these effects follows a previous description of the real gas effects in ideal pulse tube cryocoolers and makes use of models of the thermophysical properties of 3He and 4He. Published data is used to extend the analysis to mixtures of 3He and 4He. The analysis was done for pressures below 2 MPa and temperatures below 2.5 K. Both gases and their mixtures show low temperature limits for pulse tube cryocoolers. These limits are in the 0.5-2.2 K range and depend on pressure and mixture. In some circumstances, even lower temperatures may be possible. Pulse tube cryocoolers using the ha-fluid properties of dilute 3He in superfluid 4He appear to have no limit.

  19. Development of a dynamic pressure calibration technique

    NASA Technical Reports Server (NTRS)

    Vezzetti, C. F.; Hilten, J. S.; Lederer, P. S.

    1975-01-01

    The report deals with work continuing on the development of a method of producing sinusoidally varying pressures of at least 34 kPa zero-to-peak with amplitude variations within plus or minus 5% up to 2 kHz for the dynamic calibration of pressure transducers. Sinusoidally varying pressures of 34 kPa zero-to-peak were produced between 40 Hz and 750 Hz by vibrating a 10-cm column of a dimethyl siloxane liquid at 36gn zero-to-peak. Damping of the liquid column was accomplished by packing the fixture tube with a number of smaller diameter tubes.

  20. Pulsating Flows in a Tube with Expandable Wall

    NASA Astrophysics Data System (ADS)

    Raguso, Frank; Goushcha, Oleg

    2017-11-01

    A mean axial fluid flow inside a cardiovascular system has a periodic behavior driven by a heart. In one period, the flow through aorta is accelerated to a Reynolds number associated with turbulent flow and decelerated to nearly stagnant condition. The cyclic pressure in the aorta also exerts time-dependent forces on the walls of the cardiovascular system. Since walls are not rigid, they can expand under fluidic pressure. It is of interest to examine the effect of expandable walls on the flow regime transition. To achieve this, an experimental apparatus has been set up. The periodic mean axial flow inside the tubes is driven by a motor-controlled piston programmed to induce a periodic flow. A time-resolved particle image velocimetry method has been used to calculate the flow velocity field in two tubes: (1) a rigid tube and (2) a flexible tube with expandable walls. The velocity fields from two tubes were comparted to identify any differences in flow transition mechanisms.

  1. Cascading pulse tubes on a large diaphragm pressure wave generator to increase liquefaction potential

    NASA Astrophysics Data System (ADS)

    Caughley, A.; Meier, J.; Nation, M.; Reynolds, H.; Boyle, C.; Tanchon, J.

    2017-12-01

    Fabrum Solutions, in collaboration with Absolut System and Callaghan Innovation, produce a range of large pulse tube cryocoolers based on metal diaphragm pressure wave generator technology (DPWG). The largest cryocooler consists of three in-line pulse tubes working in parallel on a 1000 cm3 swept volume DPWG. It has demonstrated 1280 W of refrigeration at 77 K, from 24 kW of input power and was subsequently incorporated into a liquefaction plant to produce liquid nitrogen for an industrial customer. The pulse tubes on the large cryocooler each produced 426 W of refrigeration at 77 K. However, pulse tubes can produce more refrigeration with higher efficiency at higher temperatures. This paper presents the results from experiments to increase overall liquefaction throughput by operating one or more pulse tubes at a higher temperature to pre-cool the incoming gas. The experiments showed that the effective cooling increased to 1500 W resulting in an increase in liquefaction rate from 13 to 16 l/hour.

  2. Tube-Load Model Parameter Estimation for Monitoring Arterial Hemodynamics

    PubMed Central

    Zhang, Guanqun; Hahn, Jin-Oh; Mukkamala, Ramakrishna

    2011-01-01

    A useful model of the arterial system is the uniform, lossless tube with parametric load. This tube-load model is able to account for wave propagation and reflection (unlike lumped-parameter models such as the Windkessel) while being defined by only a few parameters (unlike comprehensive distributed-parameter models). As a result, the parameters may be readily estimated by accurate fitting of the model to available arterial pressure and flow waveforms so as to permit improved monitoring of arterial hemodynamics. In this paper, we review tube-load model parameter estimation techniques that have appeared in the literature for monitoring wave reflection, large artery compliance, pulse transit time, and central aortic pressure. We begin by motivating the use of the tube-load model for parameter estimation. We then describe the tube-load model, its assumptions and validity, and approaches for estimating its parameters. We next summarize the various techniques and their experimental results while highlighting their advantages over conventional techniques. We conclude the review by suggesting future research directions and describing potential applications. PMID:22053157

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruth, E.K.

    Measurements of pressure losses and heat transfer rates were made for an unconventional crossflow heat exchanger with tubes of lenticular cross section so spaced to reduce variation in the velocity of the fluid outside the tubes, thus reducing separation and drag. The results of these experiments are reported for various tube spacing and demonstrate that the performance of the lenticular tube heat exchanger is superior to that of conventional circular tubes by 20 percent at Reynolds numbers of 20,000 to 50,000.

  4. Advances on a cryogen-free Vuilleumier type pulse tube cryocooler

    NASA Astrophysics Data System (ADS)

    Wang, Yanan; Zhao, Yuejing; Zhang, Yibing; Wang, Xiaotao; Vanapalli, Srinivas; Dai, Wei; Li, Haibing; Luo, Ercang

    2017-03-01

    This paper presents experimental results and numerical evaluation of a Vuilleumier (VM) type pulse tube cryocooler. The cryocooler consists of three main subsystems: a thermal compressor, a low temperature pulse tube cryocooler, and a Stirling type precooler. The thermal compressor, similar to that in a Vuilleumier cryocooler, is used to drive the low temperature stage pulse tube cryocooler. The Stirling type precooler is used to establish a temperature difference for the thermal compressor to generate pressure wave. A lowest no-load temperature of 15.1 K is obtained with a pressure ratio of 1.18, a working frequency of 3 Hz and an average pressure of 2.45 MPa. Numerical simulations have been performed to help the understanding of the system performance. With given experimental conditions, the simulation predicts a lowest temperature in reasonable agreement with the experimental result. Analyses show that there is a large discrepancy in the pre-cooling power between experiments and calculation, which requires further investigation.

  5. Foam relaxation in fractures and narrow channels

    NASA Astrophysics Data System (ADS)

    Lai, Ching-Yao; Rallabandi, Bhargav; Perazzo, Antonio; Stone, Howard A.

    2017-11-01

    Various applications, from foam manufacturing to hydraulic fracturing with foams, involve pressure-driven flow of foams in narrow channels. We report a combined experimental and theoretical study of this problem accounting for the compressible nature of the foam. In particular, in our experiments the foam is initially compressed in one channel and then upon flow into a second channel the compressed foam relaxes as it moves. A plug flow is observed in the tube and the pressure at the entrance of the tube is higher than the exit. We measure the volume collected at the exit of the tube, V, as a function of injection flow rate, tube length and diameter. Two scaling behaviors for V as a function of time are observed depending on whether foam compression is important or not. Our work may relate to foam fracturing, which saves water usage in hydraulic fracturing, more efficient enhanced oil recovery via foam injection, and various materials manufacturing processes involving pressure-driven flow foams.

  6. Comparative Tests of Pitot-static Tubes

    NASA Technical Reports Server (NTRS)

    Merriam, Kenneth G; Spaulding, Ellis R

    1935-01-01

    Comparative tests were made on seven conventional Pitot-static tubes to determine their static, dynamic, and resultant errors. The effect of varying the dynamic opening, static opening, wall thickness, and inner-tube diameter was investigated. Pressure-distribution measurements showing stem and tip effects were also made. A tentative design for a standard Pitot-static tube for use in measuring air velocity is submitted.

  7. Heat exchanger with a removable tube section

    DOEpatents

    Wolowodiuk, W.; Anelli, J.

    1975-07-29

    A heat exchanger is described in which the tube sheet is secured against primary liquid pressure, but which allows for easy removal of the tube section. The tube section is supported by a flange which is secured by a number of shear blocks, each of which extends into a slot which is immovable with respect to the outer shell of the heat exchanger. (auth)

  8. Flooding Experiments and Modeling for Improved Reactor Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solmos, M.; Hogan, K. J.; Vierow, K.

    2008-09-14

    Countercurrent two-phase flow and “flooding” phenomena in light water reactor systems are being investigated experimentally and analytically to improve reactor safety of current and future reactors. The aspects that will be better clarified are the effects of condensation and tube inclination on flooding in large diameter tubes. The current project aims to improve the level of understanding of flooding mechanisms and to develop an analysis model for more accurate evaluations of flooding in the pressurizer surge line of a Pressurized Water Reactor (PWR). Interest in flooding has recently increased because Countercurrent Flow Limitation (CCFL) in the AP600 pressurizer surge linemore » can affect the vessel refill rate following a small break LOCA and because analysis of hypothetical severe accidents with the current flooding models in reactor safety codes shows that these models represent the largest uncertainty in analysis of steam generator tube creep rupture. During a hypothetical station blackout without auxiliary feedwater recovery, should the hot leg become voided, the pressurizer liquid will drain to the hot leg and flooding may occur in the surge line. The flooding model heavily influences the pressurizer emptying rate and the potential for surge line structural failure due to overheating and creep rupture. The air-water test results in vertical tubes are presented in this paper along with a semi-empirical correlation for the onset of flooding. The unique aspects of the study include careful experimentation on large-diameter tubes and an integrated program in which air-water testing provides benchmark knowledge and visualization data from which to conduct steam-water testing.« less

  9. Improving Vortex Generators to Enhance the Performance of Air-Cooled Condensers in a Geothermal Power Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manohar S. Sohal

    2005-09-01

    This report summarizes work at the Idaho National Laboratory to develop strategies to enhance air-side heat transfer in geothermal air-cooled condensers such that it should not significantly increase pressure drop and parasitic fan pumping power. The work was sponsored by the U.S. Department of Energy, NEDO (New Energy and Industrial Technology Development Organization) of Japan, Yokohama National University, and the Indian Institute of Technology, Kanpur, India. A combined experimental and numerical investigation was performed to investigate heat transfer enhancement techniques that may be applicable to largescale air-cooled condensers such as those used in geothermal power applications. A transient heat transfermore » visualization and measurement technique was employed in order to obtain detailed distributions of local heat transfer coefficients on model fin surfaces. Pressure drop measurements were obtained for a variety of tube and winglet configurations using a single-channel flow apparatus that included four tube rows in a staggered array. Heat transfer and pressure drop measurements were also acquired in a separate multiple-tube row apparatus in the Single Blow Test Facility. In addition, a numerical modeling technique was developed to predict local and average heat transfer for these low-Reynolds number flows, with and without winglets. Representative experimental and numerical results were obtained that reveal quantitative details of local finsurface heat transfer in the vicinity of a circular tube with a single delta winglet pair downstream of the cylinder. Heat transfer and pressure-drop results were obtained for flow Reynolds numbers based on channel height and mean flow velocity ranging from 700 to 6500. The winglets were of triangular (delta) shape with a 1:2 or 1:3 height/length aspect ratio and a height equal to 90% of the channel height. Overall mean fin-surface heat transfer results indicate a significant level of heat transfer enhancement (in terms of Colburn j-factor) associated with deployment of the winglets with circular as well as oval tubes. In general, toe-in (common flow up) type winglets appear to have better performance than the toe-out (common flow down) type winglets. Comparisons of heat transfer and pressure drop results for the elliptical tube versus a circular tube with and without winglets are provided. During the course of their independent research, all of the researchers have established that about 10 to 30% enhancement in Colburn j-factor is expected. However, actual increase in heat transfer rate from a heat exchanger employing finned tubes with winglets may be smaller, perhaps on the order of 2 to 5%. It is also concluded that for any specific application, more full-size experimentation is needed to optimize the winglet design for a specific heat exchanger application. If in place of a circular tube, an oval tube can be economically used in a bundle, it is expected that the pressure drop across the tube bundle with the application of vortex generators (winglets) will be similar to that in a conventional circular tube bundle. It is hoped that the results of this research will demonstrate the benefits of applying vortex generators (winglets) on the fins to improve the heat transfer from the air-side of the tube bundle.« less

  10. Shear thinning effects on blood flow in straight and curved tubes

    NASA Astrophysics Data System (ADS)

    Cherry, Erica M.; Eaton, John K.

    2013-07-01

    Simulations were performed to determine the magnitude and types of errors one can expect when approximating blood in large arteries as a Newtonian fluid, particularly in the presence of secondary flows. This was accomplished by running steady simulations of blood flow in straight and curved tubes using both Newtonian and shear-thinning viscosity models. In the shear-thinning simulations, the viscosity was modeled as a shear rate-dependent function fit to experimental data. Simulations in straight tubes were modeled after physiologically relevant arterial flows, and flow parameters for the curved tube simulations were chosen to examine a variety of secondary flow strengths. The diameters ranged from 1 mm to 10 mm and the Reynolds numbers from 24 to 1500. Pressure and velocity data are reported for all simulations. In the straight tube simulations, the shear-thinning flows had flattened velocity profiles and higher pressure gradients compared to the Newtonian simulations. In the curved tube flows, the shear-thinning simulations tended to have blunted axial velocity profiles, decreased secondary flow strengths, and decreased axial vorticity compared to the Newtonian simulations. The cross-sectionally averaged pressure drops in the curved tubes were higher in the shear-thinning flows at low Reynolds number but lower at high Reynolds number. The maximum deviation in secondary flow magnitude averaged over the cross sectional area was 19% of the maximum secondary flow and the maximum deviation in axial vorticity was 25% of the maximum vorticity.

  11. 46 CFR 56.01-2 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...”), 56.10-5; 56.60-1; (4) ASTM A 106-95, Standard Specification for Seamless Carbon Steel Pipe for High...), Standard Specification for Seamless Carbon Steel Boiler Tubes for High-Pressure Service (“ASTM A 192”), 56... Steel Boiler and Superheater Tubes for High-Pressure Service (“ASTM A 226”), 56.60-1; (19) ASTM A 234/A...

  12. 46 CFR 56.01-2 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...”), 56.10-5; 56.60-1; (4) ASTM A 106-95, Standard Specification for Seamless Carbon Steel Pipe for High...), Standard Specification for Seamless Carbon Steel Boiler Tubes for High-Pressure Service (“ASTM A 192”), 56... Steel Boiler and Superheater Tubes for High-Pressure Service (“ASTM A 226”), 56.60-1; (19) ASTM A 234/A...

  13. Integrated high pressure manifold for thermoplastic microfluidic devices

    NASA Astrophysics Data System (ADS)

    Aghvami, S. Ali; Fraden, Seth

    2017-11-01

    We introduce an integrated tubing manifold for thermoplastic microfluidic chips that tolerates high pressure. In contrast to easy tubing in PDMS microfluidic devices, tube connection has been challenging for plastic microfluidics. Our integrated manifold connection tolerates 360 psi while conventional PDMS connections fail at 50 psi. Important design considerations are incorporation of a quick-connect, leak-free and high-pressure manifold for the inlets and outlets on the lid and registration marks that allow the precise alignment of the inlets and outlets. In our method, devices are comprised of two molded pieces joined together to create a sealed device. The first piece contains the microfluidic features and the second contains the inlet and outlet manifold, a frame for rigidity and a viewing window. The mold for the lid with integrated manifold is CNC milled from aluminium. A cone shape PDMS component which acts as an O-ring, seals the connection between molded manifold and tubing. The lid piece with integrated inlet and outlets will be a standard piece and can be used for different chips and designs. Sealing the thermoplastic device is accomplished by timed immersion of the lid in a mixture of volatile and non-volatile solvents followed by application of heat and pressure.

  14. Structure and characteristics of heterogeneous detonation

    NASA Astrophysics Data System (ADS)

    Nicholls, J. A.; Sichel, M.; Kauffman, C. W.

    1983-09-01

    The emphasis of this research program centered around the structure of heterogeneous detonation waves, inasmuch as this had been found to be very important to the detonation characteristics of heterogeneous mixtures. On the experimental side, a vertical detonation tube was used wherein liquid fuel drops, all of one size, were generated at the top of the tube and allowed to fall vertically into the desired gaseous mixture. A strong blast wave was transmitted into the mixture through use of an auxiliary shock tube. The propagation of the resultant wave was monitored by pressure switches, pressure transducers, and photography. The low vapor pressure liquid fuel, decane (400 micrometer drop size) was used for most of the experiments. Attention was given to wave structure, wave velocity, and initiation energy. Three atmospheres (100% O2; 40% O2/60% N2; and air) and a number of equivalence ratios were investigated. Holographic pictures and streak photography were employed to study the drop shattering process and the structure of the front. Other experiments investigated the addition of the sensitizer, normal propyl nitrate (NPN), to the decane. The important aspect of vapor pressure was studied by heating the entire tube to various elevated temperatures and then noting the effect on detonability.

  15. Resolving Structural Isomers of Monosaccharide Methyl Glycosides Using Drift Tube and Traveling Wave Ion Mobility Mass Spectrometry

    PubMed Central

    Li, Hongli; Giles, Kevin; Bendiak, Brad; Kaplan, Kimberly; Siems, William F.; Hill, Herbert H.

    2013-01-01

    Monosaccharide structural isomers including sixteen methyl-D-glycopyranosides and four methyl-N-acetylhexosamines were subjected to ion mobility measurements by electrospray ion mobility mass spectrometry. Two ion mobility-MS systems were employed: atmospheric pressure drift tube ion mobility time-of-flight mass spectrometry and a Synapt G2 HDMS system which incorporates a low pressure traveling wave ion mobility separator. All the compounds were investigated as [M+Na]+ ions in the positive mode. A majority of the monosaccharide structural isomers exhibited different mobility drift times in either system, depending on differences in their anomeric and stereochemical configurations. In general, drift time patterns (relative drift times of isomers) matched between the two instruments. Higher resolving power was observed using the atmospheric pressure drift tube. Collision cross section values of monosaccharide structural isomers were directly calculated from the atmospheric pressure ion mobility experiments and a collision cross section calibration curve was made for the traveling wave ion mobility instrument. Overall, it was demonstrated that ion mobility-mass spectrometry using either drift tube or traveling wave ion mobility is a valuable technique for resolving subtle variations in stereochemistry among the sodium adducts of monosaccharide methyl glycosides. PMID:22339760

  16. Heat release and flame structure measurements of self-excited acoustically-driven premixed methane flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopp-Vaughan, Kristin M.; Tuttle, Steven G.; Renfro, Michael W.

    An open-open organ pipe burner (Rijke tube) with a bluff-body ring was used to create a self-excited, acoustically-driven, premixed methane-air conical flame, with equivalence ratios ranging from 0.85 to 1.05. The feed tube velocities corresponded to Re = 1780-4450. Coupled oscillations in pressure, velocity, and heat release from the flame are naturally encouraged at resonant frequencies in the Rijke tube combustor. This coupling creates sustainable self-excited oscillations in flame front area and shape. The period of the oscillations occur at the resonant frequency of the combustion chamber when the flame is placed {proportional_to}1/4 of the distance from the bottom ofmore » the tube. In this investigation, the shape of these acoustically-driven flames is measured by employing both OH planar laser-induced fluorescence (PLIF) and chemiluminescence imaging and the images are correlated to simultaneously measured pressure in the combustor. Past research on acoustically perturbed flames has focused on qualitative flame area and heat release relationships under imposed velocity perturbations at imposed frequencies. This study reports quantitative empirical fits with respect to pressure or phase angle in a self-generated pressure oscillation. The OH-PLIF images were single temporal shots and the chemiluminescence images were phase averaged on chip, such that 15 exposures were used to create one image. Thus, both measurements were time resolved during the flame oscillation. Phase-resolved area and heat release variations throughout the pressure oscillation were computed. A relation between flame area and the phase angle before the pressure maximum was derived for all flames in order to quantitatively show that the Rayleigh criterion was satisfied in the combustor. Qualitative trends in oscillating flame area were found with respect to feed tube flow rates. A logarithmic relation was found between the RMS pressure and both the normalized average area and heat release rate for all flames. (author)« less

  17. Flexible pressure sensors for burnt skin patient monitoring

    NASA Astrophysics Data System (ADS)

    Hong, Gwang-Wook; Kim, Se-Hoon; Kim, Joo-Hyung

    2015-04-01

    To monitor hypertrophic scars in burnt skin we proposed and demonstrated a hybrid polymer/carbon tube-based flexible pressure sensor. To monitor the pressure on skin by measurement, we were focusing on the fabrication of a well-defined hybrid polydimethylsiloxsane/functionalized multi-walled carbon tube array formed on the patterned interdigital transducer in a controllable way for the application of flexible pressure sensing devices. As a result, the detection at the pressure of 20 mmHg is achieved, which is a suggested optimal value of resistance for sensing pressure. It should be noted that the achieved value of resistance at the pressure of 20 mmHg is highly desirable for the further development of sensitive flexible pressure sensors. In addition we demonstrate a feasibility of a wearable pressure sensor which can be in real-time detection of local pressure by wireless communication module. Keywords:

  18. Rigid removable cover for dorsal wound protection and tube fixation in pigs.

    PubMed

    Stynes, G D; Kiroff, G K; Morrison, W A; Edwards, G A; Page, R S; Kirkland, M A

    2016-04-01

    To report the design and benefits of a rigid polyethylene cover 'shell' for the protection of dorsal torso wounds and tube fixation in pigs. Open C-shaped polyethylene shells were designed to protect wounds and dressings on the dorsum of pigs used in research into negative pressure dressing-assisted wound healing. The shells were designed to resist trauma and contamination, to be comfortable and expansible, and to facilitate tube fixation and management. Strap fixation was optimised during experimentation. Efficacy was assessed by direct observation of dressing and wound protection, tube integrity and by macroscopic and microscopic assessments of wound healing. The shells effectively protected the wounds against blunt and sharp trauma, were simple to remove and reapply, were well tolerated and allowed for growth of the pigs. Circumferential neck straps attached by lateral straps to the shells proved critical. There was no wound infection or inflammation underlying the shells. Porting tubing via mid-dorsal holes in the shells and affixing the tubing just cranial to these holes prevented tube damage and traction, permitted tube management from outside the cages and allowed the pigs to move freely without becoming entangled. These shells effectively protected dorsal skin wounds and dressings, prevented tube damage and facilitated tube management in pigs. Similar systems may be useful for other production animals for wound management and for tube management with negative pressure wound healing, drain tubes or the delivery of nutrition, fluids or medications. © 2016 Australian Veterinary Association.

  19. Impact of endotracheal tube shortening on work of breathing in neonatal and pediatric in vitro lung models.

    PubMed

    Mohr, Rebecca; Thomas, Jörg; Cannizzaro, Vincenzo; Weiss, Markus; Schmidt, Alexander R

    2017-09-01

    Work of breathing accounts for a significant proportion of total oxygen consumption in neonates and infants. Endotracheal tube inner diameter and length significantly affect airflow resistance and thus work of breathing. While endotracheal tube shortening reduces endotracheal tube resistance, the impact on work of breathing in mechanically ventilated neonates and infants remains unknown. The objective of this in vitro study was to quantify the effect of endotracheal tube shortening on work of breathing in simulated pediatric lung settings. We hypothesized that endotracheal tube shortening significantly reduces work of breathing. We used the Active-Servo-Lung 5000 to simulate different clinical scenarios in mechanically ventilated infants and neonates under spontaneous breathing with and without pressure support. Endotracheal tube size, lung resistance, and compliance, as well as respiratory settings such as respiratory rate and tidal volume were weight and age adapted for each lung model. Work of breathing was measured before and after maximal endotracheal tube shortening and the reduction of the daily energy demand calculated. Tube shortening with and without pressure support decreased work of breathing to a maximum of 10.1% and 8.1%, respectively. As a result, the calculated reduction of total daily energy demand by endotracheal tube shortening was between 0.002% and 0.02%. In this in vitro lung model, endotracheal tube shortening had minimal effects on work of breathing. Moreover, the calculated percentage reduction of the total daily energy demand after endotracheal tube shortening was minimal. © 2017 John Wiley & Sons Ltd.

  20. In-Situ Contained And Of Volatile Soil Contaminants

    DOEpatents

    Varvel, Mark Darrell

    2005-12-27

    The invention relates to a novel approach to containing and removing toxic waste from a subsurface environment. More specifically the present invention relates to a system for containing and removing volatile toxic chemicals from a subsurface environment using differences in surface and subsurface pressures. The present embodiment generally comprises a deep well, a horizontal tube, at least one injection well, at least one extraction well and a means for containing the waste within the waste zone (in-situ barrier). During operation the deep well air at the bottom of well (which is at a high pressure relative to the land surface as well as relative to the air in the contaminated soil) flows upward through the deep well (or deep well tube). This stream of deep well air is directed into the horizontal tube, down through the injection tube(s) (injection well(s)) and into the contaminate plume where it enhances volatization and/or removal of the contaminants.

  1. In-Situ Containment and Extraction of Volatile Soil Contaminants

    DOEpatents

    Varvel, Mark Darrell

    2005-12-27

    The invention relates to a novel approach to containing and removing toxic waste from a subsurface environment. More specifically the present invention relates to a system for containing and removing volatile toxic chemicals from a subsurface environment using differences in surface and subsurface pressures. The present embodiment generally comprises a deep well, a horizontal tube, at least one injection well, at least one extraction well and a means for containing the waste within the waste zone (in-situ barrier). During operation the deep well air at the bottom of well (which is at a high pressure relative to the land surface as well as relative to the air in the contaminated soil) flows upward through the deep well (or deep well tube). This stream of deep well air is directed into the horizontal tube, down through the injection tube(s) (injection well(s)) and into the contaminate plume where it enhances volatization and/or removal of the contaminants.

  2. High pressure mechanical seal

    NASA Technical Reports Server (NTRS)

    Babel, Henry W. (Inventor); Fuson, Phillip L. (Inventor); Chickles, Colin D. (Inventor); Jones, Cherie A. (Inventor); Anderson, Raymond H. (Inventor)

    1995-01-01

    A relatively impervious mechanical seal is formed between the outer surface of a tube and the inside surface of a mechanical fitting of a high pressure fluid or hydraulic system by applying a very thin soft metal layer onto the outer surface of the hard metal tube and/or inner surface of the hard metal fitting, prior to swaging the fitting onto the tube. The thickness of such thin metal layer is independent of the size of the tube and/or fittings. Many metals and alloys of those metals exhibit the requisite softness, including silver, gold, nickel, tin, platinum, indium, rhodium and cadmium. Suitably, the coating is about 0.0025 millimeters (0.10 mils) in thickness. After swaging, the tube and fitting combination exhibits very low leak rates on the order or 10.sup.-8 cubic centimeters per second or less as meaured using the Helium leak test.

  3. Transfer system

    DOEpatents

    Kurosawa, Kanji; Koga, Bunichiro; Ito, Hideki; Kiriyama, Shigeru; Higuchi, Shizuo

    2003-05-20

    A transport system includes a traveling rail (1) which constitutes a transport route and a transport body (3) which is capable of traveling on the traveling rail in the longitudinal direction of the traveling rail. Flexible drive tubes (5) are arranged on the traveling rail in the longitudinal direction of the traveling rail. The transport body includes a traveling wheel (4) which is capable of rolling on the traveling rail and drive wheels (2) which are capable of rolling on the drive tubes upon receiving the rotational drive power generated by pressure of a pressure medium supplied to the drive tubes while depressing the drive tubes. The traveling rail includes a plurality of transport sections and the transport body is capable of receiving a rotational drive force from the drive tubes at every transport sections. If necessary, a transport route changeover switch which changes over the transport route can be provided between the transport sections.

  4. Ceramic pressure housing with metal endcaps

    DOEpatents

    Downing, Jr., John P.; DeRoos, Bradley G.; Hackman, Donald J.

    1995-01-01

    A housing for the containment of instrumentation in a high pressure fluid environment that consists of a metallic endcap and ceramic cylinder bonded together. The improvement comprises a structure which results in the improved sealing of said housing as the fluid pressure increases. The cylindrical ceramic tube and endcap are dimensioned such that mechanical failure does not occur when exposed to the desired external operating pressures which includes up to 36,000 feet of water. The housing is designed to withstand the external operating pressures without being subject to mechanical failure or excessive deformation which results in the loss of pressure housing integrity via cracking or deformation of the ceramic tube, deformation of the endcap, or from failure of the bonding agent.

  5. Ceramic pressure housing with metal endcaps

    DOEpatents

    Downing, J.P. Jr.; DeRoos, B.G.; Hackman, D.J.

    1995-06-27

    A housing is disclosed for the containment of instrumentation in a high pressure fluid environment that consists of a metallic endcap and ceramic cylinder bonded together. The improvement comprises a structure which results in the improved sealing of said housing as the fluid pressure increases. The cylindrical ceramic tube and endcap are dimensioned such that mechanical failure does not occur when exposed to the desired external operating pressures which includes up to 36,000 feet of water. The housing is designed to withstand the external operating pressures without being subject to mechanical failure or excessive deformation which results in the loss of pressure housing integrity via cracking or deformation of the ceramic tube, deformation of the endcap, or from failure of the bonding agent. 9 figs.

  6. Phloem ultrastructure and pressure flow: Sieve-Element-Occlusion-Related agglomerations do not affect translocation.

    PubMed

    Froelich, Daniel R; Mullendore, Daniel L; Jensen, Kåre H; Ross-Elliott, Tim J; Anstead, James A; Thompson, Gary A; Pélissier, Hélène C; Knoblauch, Michael

    2011-12-01

    Since the first ultrastructural investigations of sieve tubes in the early 1960s, their structure has been a matter of debate. Because sieve tube structure defines frictional interactions in the tube system, the presence of P protein obstructions shown in many transmission electron micrographs led to a discussion about the mode of phloem transport. At present, it is generally agreed that P protein agglomerations are preparation artifacts due to injury, the lumen of sieve tubes is free of obstructions, and phloem flow is driven by an osmotically generated pressure differential according to Münch's classical hypothesis. Here, we show that the phloem contains a distinctive network of protein filaments. Stable transgenic lines expressing Arabidopsis thaliana Sieve-Element-Occlusion-Related1 (SEOR1)-yellow fluorescent protein fusions show that At SEOR1 meshworks at the margins and clots in the lumen are a general feature of living sieve tubes. Live imaging of phloem flow and flow velocity measurements in individual tubes indicate that At SEOR1 agglomerations do not markedly affect or alter flow. A transmission electron microscopy preparation protocol has been generated showing sieve tube ultrastructure of unprecedented quality. A reconstruction of sieve tube ultrastructure served as basis for tube resistance calculations. The impact of agglomerations on phloem flow is discussed.

  7. Phloem Ultrastructure and Pressure Flow: Sieve-Element-Occlusion-Related Agglomerations Do Not Affect Translocation[W

    PubMed Central

    Froelich, Daniel R.; Mullendore, Daniel L.; Jensen, Kåre H.; Ross-Elliott, Tim J.; Anstead, James A.; Thompson, Gary A.; Pélissier, Hélène C.; Knoblauch, Michael

    2011-01-01

    Since the first ultrastructural investigations of sieve tubes in the early 1960s, their structure has been a matter of debate. Because sieve tube structure defines frictional interactions in the tube system, the presence of P protein obstructions shown in many transmission electron micrographs led to a discussion about the mode of phloem transport. At present, it is generally agreed that P protein agglomerations are preparation artifacts due to injury, the lumen of sieve tubes is free of obstructions, and phloem flow is driven by an osmotically generated pressure differential according to Münch’s classical hypothesis. Here, we show that the phloem contains a distinctive network of protein filaments. Stable transgenic lines expressing Arabidopsis thaliana Sieve-Element-Occlusion-Related1 (SEOR1)–yellow fluorescent protein fusions show that At SEOR1 meshworks at the margins and clots in the lumen are a general feature of living sieve tubes. Live imaging of phloem flow and flow velocity measurements in individual tubes indicate that At SEOR1 agglomerations do not markedly affect or alter flow. A transmission electron microscopy preparation protocol has been generated showing sieve tube ultrastructure of unprecedented quality. A reconstruction of sieve tube ultrastructure served as basis for tube resistance calculations. The impact of agglomerations on phloem flow is discussed. PMID:22198148

  8. The Results From the First High-Pressure Melt Ejection Test Completed in the Molten Fuel Moderator Interaction Facility at Chalk River Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nitheanandan, T.; Kyle, G.; O'Connor, R.

    2006-07-01

    A high-pressure melt ejection test using prototypical corium was conducted at Atomic Energy of Canada Limited Chalk River Laboratories. This test was planned by the CANDU Owners Group to study the potential for an energetic interaction between molten fuel and water under postulated single-channel flow-blockage events. The experiments were designed to address regulator concerns surrounding this very low probability postulated accident events in CANDU Pressurized Heavy Water Reactors. The objective of the experimental program is to determine whether a highly energetic 'steam explosion' and associated high-pressure pulse, is possible when molten material is finely fragmented as it is ejected frommore » a fuel channel into the heavy-water moderator. The finely fragmented melt particles would transfer energy to the moderator as it is dispersed, creating a modest pressure pulse in the calandria vessel. The high-pressure melt ejection test consisted of heating up a {approx} 5 kg thermite mixture of U, U{sub 3}O{sub 8}, Zr, and CrO{sub 3} inside a 1.14-m length of insulated pressure tube. When the molten material reached the desired temperature of {approx} 2400 deg C, the pressure inside the tube was raised to 11.6 MPa, failing the pressure tube at a pre-machined flaw, and releasing the molten material into the surrounding tank of 68 deg C water. The experiment investigated the dynamic pressure history, debris size, and the effects of the material interacting with tubes representing neighbouring fuel channels. The measured mean particle size was 0.686 mm and the peak dynamic pressures were between 2.54 and 4.36 MPa, indicating that an energetic interaction between the melt and the water did not occur in the test. (authors)« less

  9. Design and Analysis of a Continuous Split Typed Needle-Free Injection System for Animal Vaccination.

    PubMed

    Chen, Kai; Pan, Min; Liu, Tingting

    2017-01-01

    Liquid needle-free injection devices (NFIDs) employ a high-velocity liquid jet to deliver drugs and vaccine through transdermal injection. NFIDs for animal vaccination are more complicated than those used for human beings for their much larger and more flexible power sources, as well as rapid, repetitive and continuous injection features. In the paper, spring-powered NFID is designed for animal vaccine injection. For convenience, the device is a split into a power source and handheld injector. A mathematical model is proposed to calculate the injection pressure, taking into the account pressure loss and the strain energy loss in the bendable tube due to elastic deformation. An experimental apparatus was build to verify the calculation results. Under the same system conditions, the calculation results of the dynamic injection pressure match the experimental results. It is found that the bendable tube of the split typed NFID has significant impact on the profile of the injection pressure. The initial peak pressure is less than the initial peak pressure of NFID without bendable tube, and there is occurrence time lag of the peak pressure. The mathematical model is the first attempt to reveal the relationship between the injection pressure and the system variables of split typed NFID.

  10. Pulse tube cooler having 1/4 wavelength resonator tube instead of reservoir

    NASA Technical Reports Server (NTRS)

    Gedeon, David R. (Inventor)

    2008-01-01

    An improved pulse tube cooler having a resonator tube connected in place of a compliance volume or reservoir. The resonator tube has a length substantially equal to an integer multiple of 1/4 wavelength of an acoustic wave in the working gas within the resonator tube at its operating frequency, temperature and pressure. Preferably, the resonator tube is formed integrally with the inertance tube as a single, integral tube with a length approximately 1/2 of that wavelength. Also preferably, the integral tube is spaced outwardly from and coiled around the connection of the regenerator to the pulse tube at a cold region of the cooler and the turns of the coil are thermally bonded together to improve heat conduction through the coil.

  11. Evaluation of different diameter arterial tubing and arterial cannulae in simulated neonatal/pediatric cardiopulmonary bypass circuits.

    PubMed

    Wang, Shigang; Rosenthal, Tami; Kunselman, Allen R; Ündar, Akif

    2015-01-01

    The objective of this study is to evaluate three different diameters of arterial tubing and three diameters of arterial cannulae in terms of pressure drop, and hemodynamic energy delivery in simulated neonatal/pediatric cardiopulmonary bypass (CPB) circuits. The CPB circuit consisted of a Terumo Capiox Baby FX05 oxygenator (Terumo Corporation, Tokyo, Japan), arterial tubing (1/4 in, 3/16 in, or 1/8 in × 150 cm), and a Medtronic Bio-Medicus arterial cannula (8, 10, or 12 Fr; Medtronic, Inc., Minneapolis, MN, USA). The pseudo patient's pressure was maintained at 50 mm Hg. The circuit was primed using lactated Ringer's solution and heparinized packed human red blood cells (hematocrit 30%). Trials were conducted at different flow rates and temperatures (35 and 28°C). Flow and pressure data were collected using a custom-based data acquisition system. Using 8 Fr arterial cannula at 500 mL/min, small diameter arterial tubing generated higher circuit pressure (294.6 ± 0.1 mm Hg [1/8 in], 213.5 ± 0.5 mm Hg [3/16 in], 208.4 ± 0.4 mm Hg [1/4 in] at 35°C) and arterial line pressure drop (158.3 ± 0.1 mm Hg [1/8 in], 79.6 ± 0.1 mm Hg [3/16 in], 62.1 ± 0.1 mm Hg [1/4 in] at 35°C). Using 10 Fr arterial cannula at 1000 mL/min, pre-oxygenator pressures were 266.8 ± 0.2 mm Hg (3/16 in) and 248.0 ± 0.3 mm Hg (1/4 in); arterial line pressure drops were 111.6 ± 0.0 mm Hg (3/16 in) and 74.0 ± 0.1 mm Hg (1/4 in) at 35°C. When using 12 Fr arterial cannula at 1500 mL/min, preoxygenator pressures reached 324.4 ± 0.3 mm Hg (3/16 in) and 302.5 ± 0.4 mm Hg (1/4 in); arterial line pressure drops were 154.0 ± 0.1 mm Hg (3/16 in) and 92.0 ± 0.2 mm Hg (1/4 in) at 35°C. Pressure drops across arterial line tubing were main CPB circuit pressure drops. High flow rate, hypothermia, small diameter arterial tubing. and arterial cannula created more hemodynamic energy at the preoxygenator site, but energy loss across CPB circuit also increased. Although small diameter (<1/4 in ID) arterial tubing may decrease total CPB priming volume, it also led to significantly higher circuit pressure, higher pressure drop, and more hemodynamic energy loss across CPB circuit. Larger diameter arterial cannula had less pressure drop and allowed more hemodynamic energy delivery to the patient. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Testing the Münch hypothesis of long distance phloem transport in plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knoblauch, Michael; Knoblauch, Jan; Mullendore, Daniel L.

    Long distance transport in plants occurs in sieve tubes of the phloem. The pressure flow hypothesis introduced by Ernst Münch in 1930 describes a mechanism of osmotically generated pressure differentials that are supposed to drive the movement of sugars and other solutes in the phloem, but this hypothesis has long faced major challenges. The key issue is whether the conductance of sieve tubes, including sieve plate pores, is sufficient to allow pressure flow. We show that with increasing distance between source and sink, sieve tube conductivity and turgor increases dramatically in Ipomoea nil. Our results provide strong support for themore » Münch hypothesis, while providing new tools for the investigation of one of the least understood plant tissues.« less

  13. Testing the Münch hypothesis of long distance phloem transport in plants

    DOE PAGES

    Knoblauch, Michael; Knoblauch, Jan; Mullendore, Daniel L.; ...

    2016-06-02

    Long distance transport in plants occurs in sieve tubes of the phloem. The pressure flow hypothesis introduced by Ernst Münch in 1930 describes a mechanism of osmotically generated pressure differentials that are supposed to drive the movement of sugars and other solutes in the phloem, but this hypothesis has long faced major challenges. The key issue is whether the conductance of sieve tubes, including sieve plate pores, is sufficient to allow pressure flow. We show that with increasing distance between source and sink, sieve tube conductivity and turgor increases dramatically in Ipomoea nil. Our results provide strong support for themore » Münch hypothesis, while providing new tools for the investigation of one of the least understood plant tissues.« less

  14. An improved water-filled impedance tube.

    PubMed

    Wilson, Preston S; Roy, Ronald A; Carey, William M

    2003-06-01

    A water-filled impedance tube capable of improved measurement accuracy and precision is reported. The measurement instrument employs a variation of the standardized two-sensor transfer function technique. Performance improvements were achieved through minimization of elastic waveguide effects and through the use of sound-hard wall-mounted acoustic pressure sensors. Acoustic propagation inside the water-filled impedance tube was found to be well described by a plane wave model, which is a necessary condition for the technique. Measurements of the impedance of a pressure-release terminated transmission line, and the reflection coefficient from a water/air interface, were used to verify the system.

  15. Liquid level, void fraction, and superheated steam sensor for nuclear reactor cores

    DOEpatents

    Tokarz, Richard D.

    1983-01-01

    An apparatus for detecting nominal phase conditions of coolant in a reactor vessel comprising one or more lengths of tubing each leading from a location being monitored to a closed outer end exterior of the vessel. Temperature is sensed at the open end of each length of tubing. Pressure within the tubing is also sensed. Both measurements are directed to an analyzer which compares the measured temperature to the known saturated temperature of the coolant at the measured pressure. In this manner, the nominal phase conditions of the coolant are constantly monitored.

  16. Influence of the wetting state of a heated surface on heat transfer and pressure loss in an evaporator tube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koehler, W; Hein, D

    1986-09-01

    The influence of the wetting state of a heated surface on heat transfer and pressure loss in an evaporator tube was investigated for a parameter range occurring in fossil-fired steam generators. Included in the analysis are quantities which determine the wetting state in steady and transient flow. The experimental work consists of the following: Occurrence of critical heat flux (CHF) and post-CHF heat transfer in a vertical upflow evaporator tube; influence of pressure and enthalpy transients on heat transfer in the unwetted region; influence of pipe orientation on heat transfer; and two phase flow pressure loss in wetted and unwettedmore » region. Based on these experiments a method of predicting CHF for a vertical upflow evaporator tube was developed. The heat transfer in the unwetted region was newly formulated taking into account thermal nonequilibrium between the water and steam phases. Wall temperature excursions during pressure and enthalpy transients are interpreted with the help of the boiling curve and the Leidenfrost phenomenon. A method is developed by means of which it is possible to determine the influence of the pipe orientation on the location of the boiling crisis as well as on the heat transfer in the unwetted region. The influence of the wetting state of the heated surface on the two phase flow pressure loss is interpreted as ''Wall effect'' and is calculated using a simplified computer model. 68 refs., 83 figs.« less

  17. Tube Law of the Pharyngeal Airway in Sleeping Patients with Obstructive Sleep Apnea.

    PubMed

    Genta, Pedro R; Edwards, Bradley A; Sands, Scott A; Owens, Robert L; Butler, James P; Loring, Stephen H; White, David P; Wellman, Andrew

    2016-02-01

    Obstructive sleep apnea (OSA) is characterized by repetitive pharyngeal collapse during sleep. However, the dynamics of pharyngeal narrowing and re-expansion during flow-limited breathing are not well described. The static pharyngeal tube law (end-expiratory area versus luminal pressure) has demonstrated increasing pharyngeal compliance as luminal pressure decreases, indicating that the airway would be sucked closed with sufficient inspiratory effort. On the contrary, the airway is rarely sucked closed during inspiratory flow limitation, suggesting that the airway is getting stiffer. Therefore, we hypothesized that during inspiratory flow limitation, as opposed to static conditions, the pharynx becomes stiffer as luminal pressure decreases. Upper airway endoscopy and simultaneous measurements of airflow and epiglottic pressure were performed during natural nonrapid eye movement sleep. Continuous positive (or negative) airway pressure was used to induce flow limitation. Flow-limited breaths were selected for airway cross-sectional area measurements. Relative airway area was quantified as a percentage of end-expiratory area. Inspiratory airway radial compliance was calculated at each quintile of epiglottic pressure versus airway area plot (tube law). Eighteen subjects (14 males) with OSA (apnea-hypopnea index = 57 ± 27 events/h), aged 49 ± 8 y, with a body mass index of 35 ± 6 kg/m(2) were studied. A total of 163 flow limited breaths were analyzed (9 ± 3 breaths per subject). Compliances at the fourth (2.0 ± 4.7 % area/cmH2O) and fifth (0.0 ± 1.7 % area/cmH2O) quintiles were significantly lower than the first (12.2 ± 5.5 % area/cmH2O) pressure quintile (P < 0.05). The pharyngeal tube law is concave (airway gets stiffer as luminal pressure decreases) during respiratory cycles under inspiratory flow limitation. © 2016 Associated Professional Sleep Societies, LLC.

  18. [Increasing the anode characteristics of sharp-focused Coolidge X-ray tubes by changing from a high to a low vacuum].

    PubMed

    Kanikovskiĭ, V B

    2002-01-01

    The anode characteristics of up-to-date sharp-focused Coolidge X-ray tubes are analyzed. The reason for differences in the real anode characteristics from theoretical ones has been found to be a higher tube gas pressure than that accepted. There is evidence that there are new third-class X-tubes--electronic tubes with compensation for negative volumetric charge of electrons with positive gas ions.

  19. Commercial-Off-The-Shelf Microelectromechanical Systems (MEMS) Flow-Measurement Probes Fabricated And Assembled

    NASA Technical Reports Server (NTRS)

    Redding, Chip

    2002-01-01

    As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at the NASA Glenn Research Center have been fabricating packaging components and assembling a set of unique probes using commercial-off-the-shelf microelectromechanical systems (MEMS) integrated circuits (computer chips). Using MEMS as an alternative has some compelling advantages over standard measurement devices. Sensor technologies have matured through high-production usage in industries such as automotive and aircraft manufacturers. Currently, MEMS are the choice in applications such as tire pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Conventional instrumentation uses tubing buried in the model aerodynamic surfaces or wind tunnel walls. The measurements are made when pressure is introduced at the tube opening. The pressure then must travel the tubing for lengths ranging from 20 to hundreds of feet before reaching an electronic signal conditioner. This condition causes a considerable amount of damping and requires measurements to be made only after the test rig has reached steady-state operation. The electronic MEMS pressure sensor is able to take readings continuously under dynamic states in nearly real time. The use of stainless steel tubing for pressure measurements requires many tubes to be cleaned, cut to length, carefully installed, and delicately deburred and spliced for use. A cluster of a few hundred 1/16-in.- (0.0625-in.-) diameter tubes (not uncommon in research testing facilities) can be several inches in diameter and may weigh enough to require two men to handle. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of the 1/16-in. tubing with room to spare. The P592 piezoresistive silicon pressure sensor (Lucas NovaSensor, Fremont, CA) was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The chip is 1 mm square by 0.6 mm thick (0.039 by 0.023 in.) with 0.12-mm (0.005-in.) wire connection tabs. Three MEMS chips were used to build the first type of flow-angularity probe. This MEMS probe will be demonstrated as an alternative to a standard tube type "Cobra Probe" now used routinely in wind tunnel and aeronautical hardware applications. The response time and accuracy would allow the probe to be translated on an actuator across a flow field, yielding precision dynamic measurements not possible with conventional instrumentation. The low profile, the minimal power requirement, the rugged construction, and the moderate cost all contribute to making MEMS sensors the enticing choice instrument in future research measurement needs. The MEMS probe efforts are a continuation of work initiated by Brian Willis, without whose foresight and efforts this project would never have been realized. This task was funded through cooperation with the NASA Electronic Parts and Packaging (NEPP) program at the Jet Propulsion Laboratory.

  20. Investigation on the Inertance Tubes of Pulse Tube Cryocooler Without Reservoir

    NASA Astrophysics Data System (ADS)

    Liu, Y. J.; Yang, L. W.; Liang, J. T.; Hong, G. T.

    2010-04-01

    Phase angle is of vital importance for high-efficiency pulse tube cryocoolers (PTCs). Inertance tube as the main phase shifter is useful for the PTCs to obtain appropriate phase angle. Experiments of inertance tube without reservoir under variable frequency, variable length and diameter of inertance tube and variable pressure amplitude are investigated respectively. In addition, the authors used DeltaEC, a computer program to predict the performance of low-amplitude thermoacoustic engines, to simulate the effects of inertance tube without reservoir. According to the comparison of experiments and theoretical simulations, DeltaEC method is feasible and effective to direct and improve the design of inertance tubes.

  1. 75 FR 31330 - Airworthiness Directives; Pratt & Whitney PW4000 Series Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-03

    ... No. 3 bearing oil pressure tube, part number (P/N) 51J041-01, P/N 50J604-01, or P/N 50J924-01. Tubes... also prohibit repaired tubes from being installed. This proposed AD results from one report of a repaired No. 3 bearing oil tube that caused an engine in- flight shutdown, seven reports of repaired No. 3...

  2. Modular Rake of Pitot Probes

    NASA Technical Reports Server (NTRS)

    Dunlap, Timothy A.; Henry, Michael W.; Homyk, Raymond P.

    2004-01-01

    The figure presents selected views of a modular rake of 17 pitot probes for measuring both transient and steady-state pressures in a supersonic wind tunnel. In addition to pitot tubes visible in the figure, the probe modules contain (1) high-frequency dynamic-pressure transducers connected through wires to remote monitoring circuitry and (2) flow passages that lead to tubes that, in turn, lead to remote steady-state pressure transducers. Prior pitot-probe rakes were fabricated as unitary structures, into which the individual pitot probes were brazed. Repair or replacement of individual probes was difficult, costly, and time-consuming because (1) it was necessary to remove entire rakes in order to unbraze individual malfunctioning probes and (2) the heat of unbrazing a failed probe and of brazing a new probe in place could damage adjacent probes. In contrast, the modules in the present probe are designed to be relatively quickly and easily replaceable with no heating and, in many cases, without need for removal of the entire rake from the wind tunnel. To remove a malfunctioning probe, one first removes a screw-mounted V-cross-section cover that holds the probe and adjacent probes in place. Then one removes a screw-mounted cover plate to gain access to the steady-state pressure tubes and dynamicpressure wires. Next, one disconnects the tube and wires of the affected probe. Finally, one installs a new probe in the reverse of the aforementioned sequence. The wire connections can be made by soldering, but to facilitate removal and installation, they can be made via miniature plugs and sockets. The connections between the probe flow passages and the tubes leading to the remote pressure sensors can be made by use of any of a variety of readily available flexible tubes that can be easily pulled off and slid back on for removal and installation, respectively.

  3. Behavior of fragmentation front in a porous viscoelastic material

    NASA Astrophysics Data System (ADS)

    Ichihara, M.; Takayama, K.

    2002-12-01

    We are developing laboratory experiments to investigate dynamics of magma fragmentation during explosive volcanic eruptions. Fragmentation of such a mixture as magma consisting of viscoelastic melt, bubbles and solid particles, is not known yet, and experiments are necessary to establish a mathematical model. It has been shown that viscoelastic silicone compound (Dow Corning 3179) is a useful analogous material to simulate magma fragmentation. In the previous work, a porous specimen made of the compound was rapidly decompressed and development of brittle fragmentation was observed. However, there were arguments that the experiment was different from actual processes which produce fragments as small as volcanic ash, because in the experiment the specimen was broken into only several pieces. This time, results of the improved experiments are presented. The experimental apparatus is a kind of a vertical shock tube, which mainly consists of a high pressure test section and low pressure chambers. The test section is made of acrylic tube of which inner diameter is 25 mm. The internal phenomenon is recorded by a high-speed video camera. Pressure is measured in the gas above and beneath the specimen by piezoelectric transducers. The specimen is prepared in the following way. First, an acrylic tube filled with the compound is put in a nitrogen tank and kept at 45 bar for more than 8 hours. The compound absorbs the gas and equilibrates with the nitrogen. Next, the tank is decompressed back to the atmospheric pressure slowly. Nitrogen exsolves and bubbles are formed in the compound quite uniformly. Finally, the expanded compound sticking out of both ends of the tube is cut down, and the tube containing the specimen is attached to the shock tube. The specimen is rapidly decompressed by 24, 16, and 8 bars. The high-speed video images demonstrate a sequence of the fragmentation process. We observe propagation of a clear fracture front at 50 m/s for 24 bar of decompression and at smaller speed for smaller decompression. The pressure change associated with development of the fragmentation is analyzed and effects of over pressure in the pores and permeable gas flow on fragmentation behavior are discussed.

  4. Improving the Performance of Two-Stage Gas Guns By Adding a Diaphragm in the Pump Tube

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.; Miller, Robert J.

    1995-01-01

    Herein, we study the technique of improving the gun performance by installing a diaphragm in the pump tube of the gun. A CFD study is carried out for the 0.28 in. gun in the Hypervelocity Free Flight Radiation (HFF RAD) range at the NASA Ames Research Center. The normal, full-length pump tube is studied as well as two pump tubes of reduced length (approximately 75% and approximately 33% of the normal length). Significant improvements in performance are calculated to be gained for the reduced length pump tubes upon the addition of the diaphragm. These improvements are identified as reductions in maximum pressures in the pump tube and at the projectile base of approximately 20%, while maintaining the projectile muzzle velocity or as increases in muzzle velocity of approximately 0.5 km/sec while not increasing the maximum pressures in the gun. Also, it is found that both guns with reduced pump tube length (with diaphragms) could maintain the performance of gun with the full length pump tube without diaphragms, whereas the guns with reduced pump tube lengths without diaphragms could not. A five-shot experimental investigation of the pump tube diaphragm technique is carried out for the gun with a pump tube length of 75% normal. The CFD predictions of increased muzzle velocity are borne out by the experimental data. Modest, but useful muzzle velocity increases (2.5 - 6%) are obtained upon the installation of a diaphragm, compared to a benchmark shot without a diaphragm.

  5. The origin of mean arterial and jugular venous blood pressures in giraffes.

    PubMed

    Mitchell, Graham; Maloney, Shane K; Mitchell, Duncan; Keegan, D James

    2006-07-01

    Using a mechanical model of the giraffe neck and head circulation consisting of a rigid, ascending, 'carotid' limb, a 'cranial' circulation that could be rigid or collapsible, and a descending, 'jugular' limb that also could be rigid or collapsible, we have analyzed the origin of the high arterial and venous pressures in giraffe, and whether blood flow is assisted by a siphon. When the tubes were rigid and the 'jugular' limb exit was lower than the 'carotid' limb entrance a siphon operated, 'carotid' hydrostatic pressures became more negative, and flow was 3.3 l min(-1) but ceased when the 'cranial' and 'jugular' limbs were collapsible or when the 'jugular' limb was opened to the atmosphere. Pumping water through the model produced positive pressures in the 'carotid' limb similar to those found in giraffe. Applying an external 'tissue' pressure to the 'jugular' tube during pump flow produced the typical pressures found in the jugular vein in giraffe. Constriction of the lowest, 'jugular cuff', portion of the 'jugular' limb showed that the cuff may augment the orthostatic reflex during head raising. Except when all tubes were rigid, pressures were unaffected by a siphon. We conclude that mean arterial blood pressure in giraffes is a consequence of the hydrostatic pressure generated by the column of blood in the neck, that tissue pressure around the collapsible jugular vein produces the known jugular pressures, and that a siphon does not assist flow through the cranial circulation.

  6. Method for forming a layer of synthetic corrosion products on tubing surfaces

    DOEpatents

    Lane, Michael H.; Salamon, Eugene J. M.

    1996-01-01

    A method is provided for forming a synthetic corrosion product layer on tube surfaces. The method utilizes two dissimilar materials with different coefficients of thermal expansion. An object tube and sacrificial tube are positioned one inside the other such that an annular region is created between the two tubes' surfaces. A slurry of synthetic corrosion products is injected into this annular region and the assembly is heat treated. This heat causes the tubes to expand, the inner tube with the higher coefficient of expansion expanding more than the outer tube, thereby creating internal pressures which consolidate the corrosion products and adhere the corrosion products to the tubing surfaces. The sacrificial tube may then be removed by conventional chemical etching or mechanical methods.

  7. High pressure mechanical seal

    NASA Technical Reports Server (NTRS)

    Babel, Henry W. (Inventor); Anderson, Raymond H. (Inventor)

    1996-01-01

    A relatively impervious mechanical seal is formed between the outer surface of a tube and the inside surface of a mechanical fitting of a high pressure fluid or hydraulic system by applying a very thin soft metal layer onto the outer surface of the hard metal tube and/or inner surface of the hard metal fitting. The thickness of such thin metal layer is independent of the size of the tube and/or fittings. Many metals and alloys of those metals exhibit the requisite softness, including silver, gold, tin, platinum, indium, rhodium and cadmium. Suitably, the coating is about 0.0025 millimeters (0.10 mils) in thickness. After compression, the tube and fitting combination exhibits very low leak rates on the order or 10.sup.-8 cubic centimeters per second or less as measured using the Helium leak test.

  8. Tank depletion flow controller

    DOEpatents

    Georgeson, Melvin A.

    1976-10-26

    A flow control system includes two bubbler tubes installed at different levels within a tank containing such as radioactive liquid. As the tank is depleted, a differential pressure transmitter monitors pressure differences imparted by the two bubbler tubes at a remote, shielded location during uniform time intervals. At the end of each uniform interval, balance pots containing a dense liquid are valved together to equalize the pressures. The resulting sawtooth-shaped signal generated by the differential pressure transmitter is compared with a second sawtooth signal representing the desired flow rate during each time interval. Variations in the two signals are employed by a control instrument to regulate flow rate.

  9. Benchtop study of leakages across the Portex, TaperGuard, and Microcuff endotracheal tubes under simulated clinical conditions.

    PubMed

    Lau, Arthur C W; Lam, S M; Yan, W W

    2014-02-01

    OBJECTIVES. To compare three endotracheal tubes for leakage across the cuff (microaspiration) under a comprehensive set of simulated clinical situations. These were the Mallinckrodt TaperGuard (Covidien, US) with a tapered polyvinyl chloride cuff; the KimVent Microcuff (Kimberly-Clark Health Care, US) with a cylindrical polyurethane cuff; and a conventional Portex (Smiths Medical International Ltd, UK) with a globular polyvinyl chloride cuff. DESIGN. A benchtop experimental study. SETTING AND MATERIALS. A silicone cylinder serving as the model trachea was intubated with each of the three endotracheal tubes, one at a time. A total of 20 mL of water were added above the cuff and leakage measured every minute for 20 minutes under five simulated mechanical ventilation scenarios, including different positive end-expiratory pressure levels, and disconnection with and without spontaneous breathing efforts. Each scenario was studied under three cuff pressures of 10, 20 and 30 cm H2O, and then repeated with the application of a continuous suction force of 200 cm H2O, and leakage measured every minute for 3 minutes. RESULTS. The outcome of interest was the cumulative amount of leakage. The Microcuff endotracheal tubes with an ultrathin polyurethane cuff consistently provided the best protection against microaspiration under all simulated clinical situations, followed by TaperGuard with a tapered cuff, and lastly Portex with a globular polyvinyl chloride cuff. Clinical scenarios associated with the greatest leakage were mechanical ventilation with zero positive end-expiratory pressure, circuit disconnection with spontaneous breathing efforts, application of suction, and a low cuff pressure. CONCLUSIONS. Microcuff endotracheal tubes outperformed TaperGuard and Portex endotracheal tubes in preventing microaspiration, which is one of the major mechanisms for ventilator-associated pneumonia.

  10. High-Subsonic Performance Characteristics and Boundary-Layer Investigations of a 12 deg 10-Inch-Inlet-Diameter Conical Diffuser

    DTIC Science & Technology

    1950-05-11

    available condition supersonic flow was obtained as far as K.5 inches downstream from the diffueer inlet with a maximum Mach number of M % 1.5...Boundary—layer total-pressure measurements were made with the rake shown in figure k. The tubes varied in size from 0.030-Inch outside diameter...at the wall to 0.050—inch outside diameter farther out. A static-pressure tube was mounted on the rake to measure static pressures at the same

  11. Turbulent convective heat transfer of methane at supercritical pressure in a helical coiled tube

    NASA Astrophysics Data System (ADS)

    Wang, Chenggang; Sun, Baokun; Lin, Wei; He, Fan; You, Yingqiang; Yu, Jiuyang

    2018-02-01

    The heat transfer of methane at supercritical pressure in a helically coiled tube was numerically investigated using the Reynolds Stress Model under constant wall temperature. The effects of mass flux ( G), inlet pressure ( P in) and buoyancy force on the heat transfer behaviors were discussed in detail. Results show that the light fluid with higher temperature appears near the inner wall of the helically coiled tube. When the bulk temperature is less than or approach to the pseudocritical temperature ( T pc ), the combined effects of buoyancy force and centrifugal force make heavy fluid with lower temperature appear near the outer-right of the helically coiled tube. Beyond the T pc , the heavy fluid with lower temperature moves from the outer-right region to the outer region owing to the centrifugal force. The buoyancy force caused by density variation, which can be characterized by Gr/ Re 2 and Gr/ Re 2.7, enhances the heat transfer coefficient ( h) when the bulk temperature is less than or near the T pc , and the h experiences oscillation due to the buoyancy force. The oscillation is reduced progressively with the increase of G. Moreover, h reaches its peak value near the T pc . Higher G could improve the heat transfer performance in the whole temperature range. The peak value of h depends on P in. A new correlation was proposed for methane at supercritical pressure convective heat transfer in the helical tube, which shows a good agreement with the present simulated results.

  12. Some Factors Affecting the Reproducibility of Penetration and the Cut-Off of Oil Sprays for Fuel-injection Engines

    NASA Technical Reports Server (NTRS)

    Beardsley, E G

    1928-01-01

    This investigation was undertaken at the Langley Memorial Aeronautical Laboratory in connection with a general research on fuel-injection for aircraft. The purpose of the investigation was to determine the factors controlling the reproducibility of spray penetration and secondary discharges after cut-off. The development of single sprays from automatic injection valves was recorded by means of special high-speed photographic apparatus capable of taking 25 consecutive pictures of the moving spray at a rate of 4,000 per second. The effect of two types of injection valves, injection-valve tube length, initial pressure in the injection-valve tube, speed of the injection control mechanism, and time of spray cut-off, on the reproducibility of spray penetration, and on secondary discharges were investigated. It was found that neither type of injection valve materially affected spray reproducibility. The initial pressure in the injection-valve tube controlled the reproducibility of spray penetrations. An increase in the initial pressure or in the length of the injection-valve tube slightly increased the spray penetration within the limits of this investigation. The speed of the injection-control mechanism did not affect the penetration. Analysis of the results indicates that secondary discharges were caused in this apparatus by pressure waves initiated by the rapid opening of the cut-off valve. The secondary discharges were eliminated in this investigation by increasing the length of the injection-valve tube. (author)

  13. Earache

    MedlinePlus

    ... tube drains fluid that is made in the middle ear. If the eustachian tube becomes blocked, fluid can ... of lying down can reduce pressure in the middle ear. Over-the-counter ear drops can be used ...

  14. Numerical simulation of the processes in the normal incidence tube for high acoustic pressure levels

    NASA Astrophysics Data System (ADS)

    Fedotov, E. S.; Khramtsov, I. V.; Kustov, O. Yu.

    2016-10-01

    Numerical simulation of the acoustic processes in an impedance tube at high levels of acoustic pressure is a way to solve a problem of noise suppressing by liners. These studies used liner specimen that is one cylindrical Helmholtz resonator. The evaluation of the real and imaginary parts of the liner acoustic impedance and sound absorption coefficient was performed for sound pressure levels of 130, 140 and 150 dB. The numerical simulation used experimental data having been obtained on the impedance tube with normal incidence waves. At the first stage of the numerical simulation it was used the linearized Navier-Stokes equations, which describe well the imaginary part of the liner impedance whatever the sound pressure level. These equations were solved by finite element method in COMSOL Multiphysics program in axisymmetric formulation. At the second stage, the complete Navier-Stokes equations were solved by direct numerical simulation in ANSYS CFX in axisymmetric formulation. As the result, the acceptable agreement between numerical simulation and experiment was obtained.

  15. Prediction of Burst Pressure in Multistage Tube Hydroforming of Aerospace Alloys.

    PubMed

    Saboori, M; Gholipour, J; Champliaud, H; Wanjara, P; Gakwaya, A; Savoie, J

    2016-08-01

    Bursting, an irreversible failure in tube hydroforming (THF), results mainly from the local plastic instabilities that occur when the biaxial stresses imparted during the process exceed the forming limit strains of the material. To predict the burst pressure, Oyan's and Brozzo's decoupled ductile fracture criteria (DFC) were implemented as user material models in a dynamic nonlinear commercial 3D finite-element (FE) software, ls-dyna. THF of a round to V-shape was selected as a generic representative of an aerospace component for the FE simulations and experimental trials. To validate the simulation results, THF experiments up to bursting were carried out using Inconel 718 (IN 718) tubes with a thickness of 0.9 mm to measure the internal pressures during the process. When comparing the experimental and simulation results, the burst pressure predicated based on Oyane's decoupled damage criterion was found to agree better with the measured data for IN 718 than Brozzo's fracture criterion.

  16. NACA Computers Take Readings From Manometer Boards

    NASA Image and Video Library

    1949-02-21

    Female computers at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory copy pressure readings from rows of manometers below the 18- by 18-inch Supersonic Wind Tunnel. The computers obtained test data from the manometers and other instruments, made the initial computations, and plotted the information graphically. Based on these computations, the researchers planned their next test or summarized their findings in a report. Manometers were mercury-filled glass tubes that were used to indicate different pressure levels from inside the test facility or from the test article. Manometers look and function very similarly to thermometers. Dozens of pressure sensing instruments were installed for each test. Each was connected to a manometer tube located inside the control room. The mercury inside the manometer rose and fell with the pressure levels. The dark mercury can be seen in this photograph at different levels within the tubes. Since this activity was dynamic, it was necessary to note the levels at given points during the test. This was done using both computer notations and photography.

  17. Development of dynamic calibration methods for POGO pressure transducers. [for space shuttle

    NASA Technical Reports Server (NTRS)

    Hilten, J. S.; Lederer, P. S.; Vezzetti, C. F.; Mayo-Wells, J. F.

    1976-01-01

    Two dynamic pressure sources are described for the calibration of pogo pressure transducers used to measure oscillatory pressures generated in the propulsion system of the space shuttle. Rotation of a mercury-filled tube in a vertical plane at frequencies below 5 Hz generates sinusoidal pressures up to 48 kPa, peak-to-peak; vibrating the same mercury-filled tube sinusoidally in the vertical plane extends the frequency response from 5 Hz to 100 Hz at pressures up to 140 kPa, peak-to-peak. The sinusoidal pressure fluctuations can be generated by both methods in the presence of high pressures (bias) up to 55 MPa. Calibration procedures are given in detail for the use of both sources. The dynamic performance of selected transducers was evaluated using these procedures; the results of these calibrations are presented. Calibrations made with the two sources near 5 Hz agree to within 3% of each other.

  18. Monte Carlo N-Particle Tracking of Ultrafine Particle Flow in Bent Micro-Tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casella, Andrew M.; Loyalka, Sudarsham K.

    2016-02-16

    The problem of large pressure-differential driven laminar convective-diffusive ultrafine aerosol flow through bent micro-tubes is of interest in several contemporary research areas including; release of contents from pressurized containment vessels, aerosol sampling equipment, advanced scientific instruments, gas-phase micro-heat exchangers, and microfluidic devices. In each of these areas, the predominant problem is the determination of the fraction of particles entering the micro-tube that is deposited within the tube and the fraction that is transmitted through. Due to the extensive parameter restrictions of this class of problems, a Lagrangian particle tracking method making use of the coupling of the analytical stream linemore » solutions of Dean and the simplified Langevin equation is quite a useful tool in problem characterization. This method is a direct analog to the Monte Carlo N-Particle method of particle transport extensively used in nuclear physics and engineering. In this work, 10 nm diameter particles with a density of 1 g/cm3 are tracked within micro-tubes with toroidal bends with pressure differentials ranging between 0.2175 and 0.87 atmospheres. The tubes have radii of 25 microns and 50 microns and the radius of curvature is between 1 m and 0.3183 cm. The carrier gas is helium, and temperatures of 298 K and 558 K are considered. Numerical convergence is considered as a function of time step size and of the number of particles per simulation. Particle transmission rates and deposition patterns within the bent micro-tubes are calculated.« less

  19. COAXIAL TUBE COUPLING

    DOEpatents

    Niemoth, H.R.

    1963-02-26

    BS>This patent shows a device for quickly coupling coaxial tubes in metal-to-metal fashion, so as to be suitable for use in a nuclear reactor. A threaded coliar urges a tapered metal extension on the outer coaxial tube into a tapered seat in the device and simultaneously exerts pressure through a coaxial helical spring so that a similar extension on the inner tube seats in a similar seat near the other end. (AEC)

  20. Numerical analysis of inertance pulse tube cryocooler with a modified reservoir

    NASA Astrophysics Data System (ADS)

    Abraham, Derick; Damu, C.; Kuzhiveli, Biju T.

    2017-12-01

    Pulse tube cryocoolers are used for cooling applications, where very high reliability is required as in space applications. These cryocoolers require a buffer volume depending on the temperature to be maintained and cooling load. A miniature single stage coaxial Inertance Pulse Tube Cryocooler is proposed which operates at 80 K to provide a cooling effect of at least 2 W. In this paper a pulse tube cryocooler, with modified reservoir is suggested, where the reverse fluctuation in compressor case is used instead of a steady pressure in the reservoir to bring about the desired phase shift between the pressure and the mass flow rate in the cold heat exchanger. Therefore, the large reservoir of the cryocooler is replaced by the crank volume of the hermetically sealed linear compressor, and hence the cryocooler is simplified and compact in size. The components of the cryocooler consist of a connecting tube, aftercooler, regenerator, cold heat exchanger, flow straightener, pulse tube, warm heat exchanger, inertance tube and the modified reservoir along with the losses were designed and analyzed. Each part of the cryocooler was analysed using SAGE v11 and verified with ANSYS Fluent. The simulation results clearly show that there is 50% reduction in the reservoir volume for the modified Inertance pulse tube cryocooler.

  1. Effect of Mach number, valve angle and length to diameter ratio on thermal performance in flow of air through Ranque Hilsch vortex tube

    NASA Astrophysics Data System (ADS)

    Devade, Kiran D.; Pise, Ashok T.

    2017-01-01

    Ranque Hilsch vortex tube is a device that can produce cold and hot air streams simultaneously from pressurized air. Performance of vortex tube is influenced by a number of geometrical and operational parameters. In this study parametric analysis of vortex tube is carried out. Air is used as the working fluid and geometrical parameters like length to diameter ratio (15, 16, 17, 18), exit valve angles (30°-90°), orifice diameters (5, 6 and 7 mm), 2 entry nozzles and tube divergence angle 4° is used for experimentation. Operational parameters like pressure (200-600 kPa), cold mass fraction (0-1) is varied and effect of Mach number at the inlet of the tube is investigated. The vortex tube is tested at sub sonic (0 < Ma < 1), sonic (Ma = 1) and supersonic (1 < Ma < 2) Mach number, and its effect on thermal performance is analysed. As a result it is observed that, higher COP and low cold end temperature is obtained at subsonic Ma. As CMF increases, COP rises and cold and temperature drops. Optimum performance of the tube is observed for CMF up to 0.5. Experimental correlations are proposed for optimum COP. Parametric correlation is developed for geometrical and operational parameters.

  2. 11. RW Meyer Sugar Mill: 18761889. Locomotive=type, firetube, portable boiler, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. RW Meyer Sugar Mill: 1876-1889. Locomotive=type, fire-tube, portable boiler, model No. 1, Manufactured by Ames Iron Works, Oswego, New York, 1879. 120 lbs./sq. in. working pressure, 66 sq. ft. heating surface in tubes. View: the boiler provided steam for steam engine which in turn powered the centrifugals. View shows front fire box, end of boiler. Below fire-box,used for removing ashes, is a door. Circular openings at the rear of the fire-box are where fire-tubes connected with furnace. Column to right of fire-box carried pressure and water level gauges. Fluted chimney-type structure is steam-port, safety valve, and whistle. Weights originally sat on the arm extending from the top of the port and controlled the boiler pressure. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  3. Testing the Münch hypothesis of long distance phloem transport in plants

    PubMed Central

    Knoblauch, Michael; Knoblauch, Jan; Mullendore, Daniel L; Savage, Jessica A; Babst, Benjamin A; Beecher, Sierra D; Dodgen, Adam C; Jensen, Kaare H; Holbrook, N Michele

    2016-01-01

    Long distance transport in plants occurs in sieve tubes of the phloem. The pressure flow hypothesis introduced by Ernst Münch in 1930 describes a mechanism of osmotically generated pressure differentials that are supposed to drive the movement of sugars and other solutes in the phloem, but this hypothesis has long faced major challenges. The key issue is whether the conductance of sieve tubes, including sieve plate pores, is sufficient to allow pressure flow. We show that with increasing distance between source and sink, sieve tube conductivity and turgor increases dramatically in Ipomoea nil. Our results provide strong support for the Münch hypothesis, while providing new tools for the investigation of one of the least understood plant tissues. DOI: http://dx.doi.org/10.7554/eLife.15341.001 PMID:27253062

  4. Apparatus for safeguarding a radiological source

    DOEpatents

    Bzorgi, Fariborz M

    2014-10-07

    A tamper detector is provided for safeguarding a radiological source that is moved into and out of a storage location through an access porthole for storage and use. The radiological source is presumed to have an associated shipping container approved by the U.S. Nuclear Regulatory Commission for transporting the radiological source. The tamper detector typically includes a network of sealed tubing that spans at least a portion of the access porthole. There is an opening in the network of sealed tubing that is large enough for passage therethrough of the radiological source and small enough to prevent passage therethrough of the associated shipping cask. Generally a gas source connector is provided for establishing a gas pressure in the network of sealed tubing, and a pressure drop sensor is provided for detecting a drop in the gas pressure below a preset value.

  5. Premixed direct injection nozzle for highly reactive fuels

    DOEpatents

    Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin Paul; York, William David; Uhm, Jong Ho; Zuo, Baifang

    2013-09-24

    A fuel/air mixing tube for use in a fuel/air mixing tube bundle is provided. The fuel/air mixing tube includes an outer tube wall extending axially along a tube axis between an inlet end and an exit end, the outer tube wall having a thickness extending between an inner tube surface having a inner diameter and an outer tube surface having an outer tube diameter. The tube further includes at least one fuel injection hole having a fuel injection hole diameter extending through the outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

  6. A Modelling Study for Predicting Life of Downhole Tubes Considering Service Environmental Parameters and Stress

    PubMed Central

    Zhao, Tianliang; Liu, Zhiyong; Du, Cuiwei; Hu, Jianpeng; Li, Xiaogang

    2016-01-01

    A modelling effort was made to try to predict the life of downhole tubes or casings, synthetically considering the effect of service influencing factors on corrosion rate. Based on the discussed corrosion mechanism and corrosion processes of downhole tubes, a mathematic model was established. For downhole tubes, the influencing factors are environmental parameters and stress, which vary with service duration. Stress and the environmental parameters including water content, partial pressure of H2S and CO2, pH value, total pressure and temperature, were considered to be time-dependent. Based on the model, life-span of an L80 downhole tube in oilfield Halfaya, an oilfield in Iraq, was predicted. The results show that life-span of the L80 downhole tube in Halfaya is 247 months (approximately 20 years) under initial stress of 0.1 yield strength and 641 months (approximately 53 years) under no initial stress, which indicates that an initial stress of 0.1 yield strength will reduce the life-span by more than half. PMID:28773872

  7. Concentration by centrifugation for gas exchange EPR oximetry measurements with loop-gap resonators.

    PubMed

    Subczynski, Witold K; Felix, Christopher C; Klug, Candice S; Hyde, James S

    2005-10-01

    Measurement of the bimolecular collision rate between a spin label and oxygen is conveniently carried out using a gas permeable plastic sample tube of small diameter that fits a loop-gap resonator. It is often desirable to concentrate the sample by centrifugation in order to improve the signal-to-noise ratio (SNR), but the deformable nature of small plastic sample tubes presents technical problems. Solutions to these problems are described. Two geometries were considered: (i) a methylpentene polymer, TPX, from Mitsui Chemicals, at X-band and (ii) Teflon tubing with 0.075 mm wall thickness at Q-band. Sample holders were fabricated from Delrin that fit the Eppendorf microcentrifuge tubes and support the sample capillaries. For TPX, pressure of the sealant at the end of the sample tube against the Delrin sample holder provided an adequate seal. For Teflon, the holder permitted introduction of water around the tube in order to equalize pressures across the sealant during centrifugation. Typically, the SNR was improved by a factor of five to eight. Oxygen accessibility applications in site-directed spin labeling studies are discussed.

  8. Concentration by centrifugation for gas exchange EPR oximetry measurements with loop-gap resonators

    NASA Astrophysics Data System (ADS)

    Subczynski, Witold K.; Felix, Christopher C.; Klug, Candice S.; Hyde, James S.

    2005-10-01

    Measurement of the bimolecular collision rate between a spin label and oxygen is conveniently carried out using a gas permeable plastic sample tube of small diameter that fits a loop-gap resonator. It is often desirable to concentrate the sample by centrifugation in order to improve the signal-to-noise ratio (SNR), but the deformable nature of small plastic sample tubes presents technical problems. Solutions to these problems are described. Two geometries were considered: (i) a methylpentene polymer, TPX, from Mitsui Chemicals, at X-band and (ii) Teflon tubing with 0.075 mm wall thickness at Q-band. Sample holders were fabricated from Delrin that fit the Eppendorf microcentrifuge tubes and support the sample capillaries. For TPX, pressure of the sealant at the end of the sample tube against the Delrin sample holder provided an adequate seal. For Teflon, the holder permitted introduction of water around the tube in order to equalize pressures across the sealant during centrifugation. Typically, the SNR was improved by a factor of five to eight. Oxygen accessibility applications in site-directed spin labeling studies are discussed.

  9. Development of a prototype flexible radiator system

    NASA Technical Reports Server (NTRS)

    Hixon, C. W.

    1979-01-01

    The radiator is a roll-up flexible panel with the transport fluid manifolds located at the ends of the 27 foot length. A total of fifty Teflon flow tubes are sandwiched between the layers of silver wire mesh and sealed in the Teflon film. The transport fluid flows from an inlet manifold through 25 panel flow tubes to the end of the radiator panel into a manifold which directs the fluid into the other 25 flow tubes on its return to the base of the radiator. Deployment/retraction of the flexible radiator panel is by low pressure inflation tubes (one along each side of the panel) which incorporate a flat spring. The spring supplies the retraction force to wind the radiator panel on a drum when the pressure in the inflation tubes is relieved. Room ambient deployment tests of the radiator panel were conducted to verify the inflation tube spring deployment, and retraction capability. The panel underwent a thermal vacuum, solar spectrum exposure test. After approximately 100 hours of solar exposure, post-test inspection revealed no structural or optical properties degraded.

  10. Transfer of a cold atmospheric pressure plasma jet through a long flexible plastic tube

    NASA Astrophysics Data System (ADS)

    Kostov, Konstantin G.; Machida, Munemasa; Prysiazhnyi, Vadym; Honda, Roberto Y.

    2015-04-01

    This work proposes an experimental configuration for the generation of a cold atmospheric pressure plasma jet at the downstream end of a long flexible plastic tube. The device consists of a cylindrical dielectric chamber where an insulated metal rod that serves as high-voltage electrode is inserted. The chamber is connected to a long (up to 4 m) commercial flexible plastic tube, equipped with a thin floating Cu wire. The wire penetrates a few mm inside the discharge chamber, passes freely (with no special support) along the plastic tube and terminates a few millimeters before the tube end. The system is flushed with Ar and the dielectric barrier discharge (DBD) is ignited inside the dielectric chamber by a low frequency ac power supply. The gas flow is guided by the plastic tube while the metal wire, when in contact with the plasma inside the DBD reactor, acquires plasma potential. There is no discharge inside the plastic tube, however an Ar plasma jet can be extracted from the downstream tube end. The jet obtained by this method is cold enough to be put in direct contact with human skin without an electric shock. Therefore, by using this approach an Ar plasma jet can be generated at the tip of a long plastic tube far from the high-voltage discharge region, which provides the safe operation conditions and device flexibility required for medical treatment.

  11. Pool boiling of nanofluids on rough and porous coated tubes: experimental and correlation

    NASA Astrophysics Data System (ADS)

    Cieśliński, Janusz T.; Kaczmarczyk, Tomasz Z.

    2014-06-01

    The paper deals with pool boiling of water-Al2O3 and water- Cu nanofluids on rough and porous coated horizontal tubes. Commercially available stainless steel tubes having 10 mm outside diameter and 0.6 mm wall thickness were used to fabricate the test heater. The tube surface was roughed with emery paper 360 or polished with abrasive compound. Aluminium porous coatings of 0.15 mm thick with porosity of about 40% were produced by plasma spraying. The experiments were conducted under different absolute operating pressures, i.e., 200, 100, and 10 kPa. Nanoparticles were tested at the concentration of 0.01, 0.1, and 1% by weight. Ultrasonic vibration was used in order to stabilize the dispersion of the nanoparticles. It was observed that independent of operating pressure and roughness of the stainless steel tubes addition of even small amount of nanoparticles augments heat transfer in comparison to boiling of distilled water. Contrary to rough tubes boiling heat transfer coefficient of tested nanofluids on porous coated tubes was lower compared to that for distilled water while boiling on porous coated tubes. A correlation equation for prediction of the average heat transfer coefficient during boiling of nanofluids on smooth, rough and porous coated tubes is proposed. The correlation includes all tested variables in dimensionless form and is valid for low heat flux, i.e., below 100 kW/m2.

  12. The compression and expansion waves of the forward and backward flows: an in-vitro arterial model.

    PubMed

    Feng, J; Khir, A W

    2008-05-01

    Although the propagation of arterial waves of forward flows has been studied before, that of backward flows has not been thoroughly investigated. The aim of this research is to investigate the propagation of the compression and expansion waves of backward flows in terms of wave speed and dissipation, in flexible tubes. The aim is also to compare the propagation of these waves with those of forward flows. A piston pump generated a flow waveform in the shape of approximately half-sinusoid, in flexible tubes (12 mm and 16 mm diameter). The pump produced flow in either the forward or the backward direction by moving the piston forward, in a 'pushing action' or backward, in a 'pulling action', using a graphite brushes d.c. motor. Pressure and flow were measured at intervals of 5 cm along each tube and wave speed was determined using the PU-loop method. The simultaneous measurements of diameter were also taken at the same position of the pressure and flow in the 16 mm tube. Wave intensity analysis was used to determine the magnitude of the pressure and velocity waveforms and wave intensity in the forward and backward directions. Under the same initial experimental conditions, wave speed was higher during the pulling action (backward flow) than during the pushing action (forward flow). The amplitudes of pressure and velocity in the pulling action were significantly higher than those in the pushing action. The tube diameter was approximately 20 per cent smaller in the pulling action than in the pushing action in the 16 mm tube. The compression and expansion waves resulting from the pushing and pulling actions dissipated exponentially along the travelling distance, and their dissipation was greater in the smaller than in the larger tubes. Local wave speed in flexible tubes is flow direction- and wave nature-dependent and is greater with expansion than with compression waves. Wave dissipation has an inverse relationship with the vessel diameter, and dissipation of the expansion wave of the pulling action was greater than that of the pushing action.

  13. Correlation of heat transfer for the zero pressure gradient hypersonic laminar boundary layer for several gases

    NASA Technical Reports Server (NTRS)

    Cook, W. J.

    1973-01-01

    A theoretical study of heat transfer for zero pressure gradient hypersonic laminar boundary layers for various gases with particular application to the flows produced in an expansion tube facility was conducted. A correlation based on results obtained from solutions to the governing equations for five gases was formulated. Particular attention was directed toward the laminar boundary layer shock tube splitter plates in carbon dioxide flows generated by high speed shock waves. Computer analysis of the splitter plate boundary layer flow provided information that is useful in interpreting experimental data obtained in shock tube gas radiation studies.

  14. Optimization of a Tube Hydroforming Process

    NASA Astrophysics Data System (ADS)

    Abedrabbo, Nader; Zafar, Naeem; Averill, Ron; Pourboghrat, Farhang; Sidhu, Ranny

    2004-06-01

    An approach is presented to optimize a tube hydroforming process using a Genetic Algorithm (GA) search method. The goal of the study is to maximize formability by identifying the optimal internal hydraulic pressure and feed rate while satisfying the forming limit diagram (FLD). The optimization software HEEDS is used in combination with the nonlinear structural finite element code LS-DYNA to carry out the investigation. In particular, a sub-region of a circular tube blank is formed into a square die. Compared to the best results of a manual optimization procedure, a 55% increase in expansion was achieved when using the pressure and feed profiles identified by the automated optimization procedure.

  15. Gaseous Detonation-Driven Fracture of Tubes

    DTIC Science & Technology

    2004-03-01

    understanding, in addition to leading to safer piping system design in nuclear power plants, can also assist accident investigators in learning what type...load, there are derived expressions in the literature from which one can learn about some essential features of mode I dynamic fracture. For a...along a 0.2-mm deep longitudinal groove. Pressure histories were measured by pressure transducers mounted inside the tube, axial and circumferen- tial

  16. High Pressure Pneumatic Forming of Ti-3Al-2.5V Titanium Tubes in a Square Cross-Sectional Die

    PubMed Central

    Liu, Gang; Wang, Jianlong; Dang, Kexin; Tang, Zejun

    2014-01-01

    A new high strain rate forming process for titanium alloys is presented and named High Pressure Pneumatic Forming (HPPF), which might be applicable to form certain tubular components with irregular cross sections with high efficiency, both with respect to energy cost and time consumption. HPPF experiments were performed on Ti-3Al-2.5V titanium alloy tubes using a square cross-sectional die with a small corner radius. The effects of forming of pressure and temperature on the corner filling were investigated and the thickness distributions after the HPPF processes at various pressure levels are discussed. At the same time, the stress state, strain and strain rate distribution during the HPPF process were numerically analyzed by the finite element method. Microstructure evolution of the formed tubes was also analyzed by using electron back scattering diffraction (EBSD). Because of different stress states, the strain and strain rate are very different at different areas of the tube during the corner filling process, and consequently the microstructure of the formed component is affected to some degree. The results verified that HPPF is a potential technology to form titanium tubular components with complicated geometrical features with high efficiency. PMID:28788173

  17. ORCHID - a computer simulation of the reliability of an NDE inspection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moles, M.D.C.

    1987-03-01

    CANDU pressurized heavy water reactors contain several hundred horizontally-mounted zirconium alloy pressure tubes. Following a pressure tube failure, a pressure tube inspection system called CIGARette was rapidly designed, manufactured and put in operation. Defects called hydride blisters were found to be the cause of the failure, and were detected using a combination of eddy current and ultrasonic scans. A number of improvements were made to CIGARette during the inspection period. The ORCHID computer program models the operation of the delivery system, eddy current and ultrasonic systems by imitating the on-reactor decision-making procedure. ORCHID predicts that during the early stage ofmore » development, less than one blistered tube in three would be detected, while less than one in two would be detected in the middle development stage. However, ORCHID predicts that during the late development stage, probability of detection will be over 90%, primarily due to the inclusion of axial ultrasonic scans (a procedural modification). Rotational and axial slip could severely reduce probability of detection. Comparison of CIGARette's inspection data with ORCHID's predictions indicate that the latter are compatible with the actual inspection results, through the numbers are small and data uncertain. It should be emphasized that the CIGARette system has been essentially replaced with the much more reliable CIGAR system.« less

  18. Feasibility study of an active soft catheter actuated by SMA wires

    NASA Astrophysics Data System (ADS)

    Konh, Bardia; Karimi, Saeed; Miller, Scott

    2018-03-01

    This study aims to assess the feasibility of using a combination of thin elastomer tubes and SMA wires to develop an active catheter. Cardiac catheters have been widely used in investigational and interventional procedures such as angiography, angioplasty, electro- physiology, and endocardial ablation. The commercial models manually steer inside the patient's body via internally installed pull wires. Active catheters, on the other hand, have the potential to revolutionize surgical procedures because of their computer-controlled and enhanced motion. Shape memory alloys have been used for almost a decade as a trustworthy actuator for biomedical applications. In this work, SMA wires were attached to a small pressurized elastomer tube to realize deflection. The tube was pressurized to maintain a constant stress on the SMA wires. The tip motion via actuation of SMA wires was then measured and reported. The results of this study showed that by adopting an appropriate training process for the SMA wires prior to performing the experiments and adopting an appropriate internal pressure for the elastomer tube, less external loads on SMA wires would be needed for a consistent actuation.

  19. Experiments of draining and filling processes in a collapsible tube at high external pressure

    NASA Astrophysics Data System (ADS)

    Flaud, P.; Guesdon, P.; Fullana, J.-M.

    2012-02-01

    The venous circulation in the lower limb is mainly controlled by the muscular action of the calf. To study the mechanisms governing the venous draining and filling process in such a situation, an experimental setup, composed by a collapsible tube under external pressure, has been built. A valve preventing back flows is inserted at the bottom of the tube and allows to model two different configurations: physiological when the fluid flow is uni-directional and pathological when the fluid flows in both directions. Pressure and flow rate measurements are carried out at the inlet and outlet of the tube and an original optical device with three cameras is proposed to measure the instantaneous cross-sectional area. The experimental results (draining and filling with physiological or pathological valves) are confronted to a simple one-dimensional numerical model which completes the physical interpretation. One major observation is that the muscular contraction induces a fast emptying phase followed by a slow one controlled by viscous effects, and that a defect of the valve decreases, as expected, the ejected volume.

  20. Numerical modeling of an experimental shock tube for traumatic brain injury studies

    NASA Astrophysics Data System (ADS)

    Phillips, Michael; Regele, Jonathan D.

    2015-11-01

    Unfortunately, Improvised Explosive Devices (IEDs) are encountered commonly by both civilians and military soldiers throughout the world. Over a decade of medical history suggests that traumatic brain injury (TBI) may result from exposure to the blast waves created by these explosions, even if the person does not experience any immediate injury or lose consciousness. Medical researchers study the exposure of mice and rats to blast waves created in specially designed shock tubes to understand the effect on brain tissue. A newly developed table-top shock tube with a short driver section has been developed for mice experiments to reduce the time necessary to administer the blast radiation and increase the amount of statistical information available. In this study, numerical simulations of this shock tube are performed to assess how the blast wave takes its shape. The pressure profiles obtained from the numerical results are compared with the pressure histories from the experimental pressure transducers. The results show differences in behavior from what was expected, but the blast wave may still be an effective means of studying TBI.

  1. Wavelet analysis of poorly-focused ultrasonic signal of pressure tube inspection in nuclear industry

    NASA Astrophysics Data System (ADS)

    Zhao, Huan; Gachagan, Anthony; Dobie, Gordon; Lardner, Timothy

    2018-04-01

    Pressure tube fabrication and installment challenges combined with natural sagging over time can produce issues with probe alignment for pressure tube inspection of the primary circuit of CANDU reactors. The ability to extract accurate defect depth information from poorly focused ultrasonic signals would reduce additional inspection procedures, which leads to a significant time and cost saving. Currently, the defect depth measurement protocol is to simply calculate the time difference between the peaks of the echo signals from the tube surface and the defect from a single element probe focused at the back-wall depth. When alignment issues are present, incorrect focusing results in interference within the returning echo signal. This paper proposes a novel wavelet analysis method that employs the Haar wavelet to decompose the original poorly focused A-scan signal and reconstruct detailed information based on a selected high frequency component range within the bandwidth of the transducer. Compared to the original signal, the wavelet analysis method provides additional characteristic defect information and an improved estimate of defect depth with errors less than 5%.

  2. R245fa Flow Boiling inside a 4.2 mm ID Microfin Tube

    NASA Astrophysics Data System (ADS)

    Longo, G. A.; Mancin, S.; Righetti, G.; Zilio, C.

    2017-11-01

    This paper presents the R245fa flow boiling heat transfer and pressure drop measurements inside a mini microfin tube with internal diameter at the fin tip of 4.2 mm, having 40 fins, 0.15 mm high with a helix angle of 18°. The tube was brazed inside a copper plate and electrically heated from the bottom. Sixteen T-type thermocouples are located in the copper plate to monitor the wall temperature. The experimental measurements were carried out at constant mean saturation temperature of 30 °C, by varying the refrigerant mass velocity between 100 kg m-2 s-1 and 300 kg m-2 s-1, the vapour quality from 0.15 to 0.95, at two different heat fluxes: 30 and 60 kW m-2. The experimental results are presented in terms of two-phase heat transfer coefficient, onset dryout vapour quality, and frictional pressure drop. Moreover, the experimental measurements are compared against the most updated models for boiling heat transfer coefficient and frictional pressure drop estimations available in the open literature for microfin tubes.

  3. Controlled microaspiration for high-pressure freezing: a new method for ultrastructural preservation of fragile and sparse tissues for TEM and electron tomography

    PubMed Central

    Triffo, W. J.; Palsdottir, H.; McDonald, K. L.; Lee, J. K.; Inman, J. L.; Bissell, M. J.; Raphael, R. M.; Auer, M.

    2009-01-01

    Summary High-pressure freezing is the preferred method to prepare thick biological specimens for ultrastructural studies. However, the advantages obtained by this method often prove unattainable for samples that are difficult to handle during the freezing and substitution protocols. Delicate and sparse samples are difficult to manipulate and maintain intact throughout the sequence of freezing, infiltration, embedding and final orientation for sectioning and subsequent transmission electron microscopy. An established approach to surmount these difficulties is the use of cellulose microdialysis tubing to transport the sample. With an inner diameter of 200 µm, the tubing protects small and fragile samples within the thickness constraints of high-pressure freezing, and the tube ends can be sealed to avoid loss of sample. Importantly, the transparency of the tubing allows optical study of the specimen at different steps in the process. Here, we describe the use of a micromanipulator and microinjection apparatus to handle and position delicate specimens within the tubing. We report two biologically significant examples that benefit from this approach, 3D cultures of mammary epithelial cells and cochlear outer hair cells. We illustrate the potential for correlative light and electron microscopy as well as electron tomography. PMID:18445158

  4. Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

    NASA Technical Reports Server (NTRS)

    Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.

    1998-01-01

    Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

  5. In vitro estimation of pressure drop across tracheal tubes during high-frequency percussive ventilation.

    PubMed

    Ajčević, M; Lucangelo, U; Ferluga, M; Zin, W A; Accardo, A

    2014-02-01

    Tracheal tubes (TT) are used in clinical practice to connect an artificial ventilator to the patient's airways. It is important to know the pressure used to overcome tube impedance to avoid lung injury. Although high-frequency percussive ventilation (HFPV) has been increasingly used, the mechanical behavior of TT under HFPV has not yet been described. Thus, we aimed at characterizing in vitro the pressure drop across TT (ΔPTT) by identifying the model that best fits the measured pressure-flow (P-V̇) relationships during HFPV under different working pressures (PWork), percussive frequencies and mechanical loads. Three simple models relating ΔPTT and flow (V̇) were tested. Model 1 is characterized by linear resistive [Rtube ⋅ V̇(t)] and inertial [I · V̈(t)] terms. Model 2 takes into consideration Rohrer's approach [K1· V̇(t) + K2 ⋅V̇(t)] and inertance [I ·V̈(t)]. In model 3 the pressure drop caused by friction is represented by the non-linear Blasius component [Kb· V̇(1.75)(t)] and the inertial term [I· V̈(t)]. Model 1 presented a significantly higher root mean square error of approximation than models 2 and 3, which were similar. Thus, model 1 was not as accurate as the latter, possibly due to turbulence. Model 3 presented the most robust resistance-related coefficient. Estimated inertances did not vary among the models using the same tube. In conclusion, in HFPV ΔPTT can be easily calculated by the physician using model 3.

  6. The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator.

    PubMed

    White, Donna M; Redondo, José I; Mair, Alastair R; Martinez-Taboada, Fernando

    2017-09-01

    The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator. Prospective, experimental clinical study. Participants included veterinary students at the beginning (group S1) and end (group S2) of their 2-week anaesthesia rotation and veterinary anaesthetists (group A). The feline airway simulator was designed to simulate an average size feline trachea, intubated with a 4.5 mm low-pressure, high-volume cuffed endotracheal tube, connected to a Bain breathing system with oxygen flow of 2 L minute -1 . Participants inflated the on-endotracheal tube cuff by pilot balloon palpation and by instilling the minimum occlusive volume (MOV) required for loss of airway leaks during manual ventilation. Intracuff pressures were measured by manometers obscured to participants and ideally were 20-30 cm H 2 O. Student t, Fisher exact, and Chi-squared tests were used where appropriate to analyse data (p < 0.05). Participants were 12 students and eight anaesthetists. Measured intracuff pressures for palpation and MOV, respectively, were 19 ± 12 and 29 ± 19 cm H 2 O for group S1, 10 ± 5 and 20 ± 11 cm H 2 O for group S2 and 13 ± 6 and 29 ± 18 cm H 2 O for group A. All groups performed poorly at achieving intracuff pressures within the ideal range. There was no significant difference in intracuff pressures between techniques. Students administered lower (p = 0.02) intracuff pressures using palpation after their training. When using palpation and MOV for cuff inflation operators rarely achieved optimal intracuff pressures. Experience had no effect on this skill and, as such, a cuff manometer is recommended. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  7. Thermodynamic analyses and the experimental validation of the Pulse Tube Expander system

    NASA Astrophysics Data System (ADS)

    Jia, Qiming; Gong, Linghui; Feng, Guochao; Zou, Longhui

    2018-04-01

    A Pulse Tube Expander (PTE) for small and medium capacity cryogenic refrigeration systems is described in this paper. An analysis of the Pulse Tube Expander is developed based on the thermodynamic analyses of the system. It is shown that the gas expansion is isentropic in the cold end of the pulse tube. The temperature variation at the outlet of Pulse Tube Expander is measured and the isentropic efficiency is calculated to be 0.455 at 2 Hz. The pressure oscillations in the pulse tube are obtained at different frequencies. The limitations and advantages of this system are also discussed.

  8. Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS

    PubMed Central

    Weisberg, Stacy N.; McCall, Jonathan C.; Tennyson, Joseph

    2017-01-01

    Introduction Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. Methods ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH2O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. Results We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH2O. Maximum altitude for the program ranged from 1,000–3,000 feet above sea level, with a change in altitude from 800–2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH2O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Conclusion Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs. PMID:28611883

  9. Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS.

    PubMed

    Weisberg, Stacy N; McCall, Jonathan C; Tennyson, Joseph

    2017-06-01

    Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH 2 O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH 2 O. Maximum altitude for the program ranged from 1,000-3,000 feet above sea level, with a change in altitude from 800-2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH 2 O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Shyy Woei; Yang, Tsun Lirng; Liou, Jin Shuen

    An experimental study measuring the axial heat transfer distributions and the pressure drop coefficients of the tube fitted with a broken twisted tape of twist ratio 1, 1.5, 2, 2.5 or {infinity} is performed in the Re range of 1000-40,000. This type of broken twisted tape is newly invented without previous investigations available. Local Nusselt numbers and mean Fanning friction factors in the tube fitted with the broken twisted tape increase as the twist ratio decreases. Heat transfer coefficients, mean Fanning friction factors and thermal performance factors in the tube fitted with the broken twisted tape are, respectively, augmented tomore » 1.28-2.4, 2-4.7 and 0.99-1.8 times of those in the tube fitted with the smooth twisted tape. Empirical heat transfer and pressure drop correlations which evaluate the local Nusselt number and the mean Fanning friction factor for the tube with the broken twisted tape insert are generated to assist the industrial applications. (author)« less

  11. Improvement of Die Corner Filling in Box-shape Stepped Tubes Hydroforming

    NASA Astrophysics Data System (ADS)

    Hosseini-Farrash, S. H.; Elyasi, M.; Bakhshi-Jooybari, M.; Gorji, A.

    2011-01-01

    A new die design to improve the die corner filling in the hydroforming of square-sectional stepped tubes is presented. The proposed die-set contains two additional bushes, compared to the common tube hydroforming dies. First, the tube is placed into the die, filled with liquid, and sealed with the punches. Then, by increasing the internal pressure, the tube is bulged and contacts the die walls (bulging stage). By maintaining the internal pressure, the two upper and lower bushes move until the die cavity is filled completely (calibration stage). The proposed die was simulated and the results show that sharp corners of the part and relatively complete filling of the die cavity can be obtained by using this die set. In order to verify the results, some experiments have been carried out. The experimental results verified the results obtained from the simulations. The thickness distribution of the part is also investigated and it is shown that fairly uniform thickness distribution can be obtained by using the proposed die set.

  12. A novel coupled VM-PT cryocooler operating at liquid helium temperature

    NASA Astrophysics Data System (ADS)

    Pan, Changzhao; Zhang, Tong; Zhou, Yuan; Wang, Junjie

    2016-07-01

    This paper presents experimental results on a novel two-stage gas-coupled VM-PT cryocooler, which is a one-stage VM cooler coupled a pulse tube cooler. In order to reach temperatures below the critical point of helium-4, a one-stage coaxial pulse tube cryocooler was gas-coupled on the cold end of the former VM cryocooler. The low temperature inertance tube and room temperature gas reservoir were used as phase shifters. The influence of room temperature double-inlet was first investigated, and the results showed that it added excessive heat loss. Then the inertance tube, regenerator and the length of the pulse tube were researched experimentally. Especially, the DC flow, whose function is similar to the double-orifice, was experimentally studied, and shown to contribute about 0.2 K for the no-load temperature. The minimum no-load temperature of 4.4 K was obtained with a pressure ratio near 1.5, working frequency of 2.2 Hz, and average pressure of 1.73 MPa.

  13. Experimental study on heat transfer to supercritical water flowing through tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, M.; Gu, H.; Cheng, X.

    2012-07-01

    A test facility named SWAMUP (Supercritical Water Multi-Purpose Loop) has been constructed in Shanghai Jiao Tong Univ. to investigate heat transfer and pressure drop through tubes and rod bundles. SWAMUP is a closed loop with operating pressure up to 30 MPa, outlet-water temperature up to 550 deg. C, and mass flow rate up to 5 t/h. In this paper, experimental study has been carried out on heat transfer of supercritical water flowing vertically through tubes (ID=7.6 and 10 mm). A large number of test points in tubes has been obtained with a wide range of heat flux (200-1500 kw/m{sup 2})more » and mass flux (450-2000 kg/m{sup 2}s). Test results showed that heat transfer deterioration (HTD) caused by buoyancy effect only appears in upward flow and HTD caused by acceleration effect appears both in upward flow and downward flow. The heat transfer coefficients (HTC) produced in tube tests were compared with existing heat transfer correlations. (authors)« less

  14. Shape optimized headers and methods of manufacture thereof

    DOEpatents

    Perrin, Ian James

    2013-11-05

    Disclosed herein is a shape optimized header comprising a shell that is operative for collecting a fluid; wherein an internal diameter and/or a wall thickness of the shell vary with a change in pressure and/or a change in a fluid flow rate in the shell; and tubes; wherein the tubes are in communication with the shell and are operative to transfer fluid into the shell. Disclosed herein is a method comprising fixedly attaching tubes to a shell; wherein the shell is operative for collecting a fluid; wherein an internal diameter and/or a wall thickness of the shell vary with a change in pressure and/or a change in a fluid flow rate in the shell; and wherein the tubes are in communication with the shell and are operative to transfer fluid into the shell.

  15. A microfluidic tubing method and its application for controlled synthesis of polymeric nanoparticles.

    PubMed

    Wang, Jidong; Chen, Wenwen; Sun, Jiashu; Liu, Chao; Yin, Qifang; Zhang, Lu; Xianyu, Yunlei; Shi, Xinghua; Hu, Guoqing; Jiang, Xingyu

    2014-05-21

    This report describes a straightforward but robust tubing method for connecting polydimethylsiloxane (PDMS) microfluidic devices to external equipment. The interconnection is irreversible and can sustain a pressure of up to 4.5 MPa that is characterized experimentally and theoretically. To demonstrate applications of this high-pressure tubing technique, we fabricate a semicircular microfluidic channel to implement a high-throughput, size-controlled synthesis of poly(lactic-co-glycolic acid) (PLGA) nanoparticles ranging from 55 to 135 nm in diameter. This microfluidic device allows for a total flow rate of 410 mL h(-1), resulting in enhanced convective mixing which can be utilized to precipitate small size nanoparticles with a good dispersion. We expect that this tubing technique would be widely used in microfluidic chips for nanoparticle synthesis, cell manipulation, and potentially nanofluidic applications.

  16. NUCLEAR REACTOR

    DOEpatents

    Treshow, M.

    1958-08-19

    A neuclear reactor is described of the heterogeneous type and employing replaceable tubular fuel elements and heavy water as a coolant and moderator. A pluraltty of fuel tubesa having their axes parallel, extend through a tank type pressure vessel which contatns the liquid moderator. The fuel elements are disposed within the fuel tubes in the reaetive portion of the pressure vessel during normal operation and the fuel tubes have removable plug members at each end to permit charging and discharging of the fuel elements. The fuel elements are cylindrical strands of jacketed fissionable material having helical exterior ribs. A bundle of fuel elements are held within each fuel tube with their longitudinal axes parallel, the ribs serving to space them apart along their lengths. Coolant liquid is circulated through the fuel tubes between the spaced fuel elements. Suitable control rod and monitoring means are provided for controlling the reactor.

  17. Development of single crystal membranes

    NASA Technical Reports Server (NTRS)

    Stormont, R. W.; Cocks, F. H.

    1972-01-01

    The design and construction of a high pressure crystal growth chamber was accomplished which would allow the growth of crystals under inert gas pressures of 2 MN/sq m (300 psi). A novel crystal growth technique called EFG was used to grow tubes and rods of the hollandite compounds, BaMgTi7O16, K2MgTi7O16, and tubes of sodium beta-alumina, sodium magnesium-alumina, and potassium beta-alumina. Rods and tubes grown are characterized using metallographic and X-ray diffraction techniques. The hollandite compounds are found to be two or three-phase, composed of coarse grained orientated crystallites. Single crystal c-axis tubes of sodium beta-alumina were grown from melts containing excess sodium oxide. Additional experiments demonstrated that crystals of magnesia doped beta-alumina and potassium beta-alumina also can be achieved by this EFG technique.

  18. Experimental Study on Flow Boiling of Carbon Dioxide in a Horizontal Microfin Tube

    NASA Astrophysics Data System (ADS)

    Kuwahara, Ken; Ikeda, Soshi; Koyama, Shigeru

    This paper deals with the experimental study on flow boiling heat transfer of carbon dioxide in a micro-fin tube. The geometrical parameters of micro-fin tube used in this study are 6.07 mm in outer diameter, 5.24 mm in average inner diameter, 0.256 mm in fin height, 20.4 in helix angle, 52 in number of grooves and 2.35 in area expansion ratio. Flow patterns and heat transfer coefficients were measured at 3-5 MPa in pressure, 300-540 kg/(m2s) in mass velocity and -5 to 15 °C in CO2 temperature. Flow patterns of wavy flow, slug flow and annular flow were observed. The measured heat transfer coefficients of micro-fin tube were 10-40 kW/(m2K). Heat transfer coefficients were strongly influenced by pressure.

  19. Aperiodic pressure pulsation under non optimal hydraulic turbine regimes at low swirl number

    NASA Astrophysics Data System (ADS)

    Skripkin, S. G.; Tsoy, M. A.; Kuibin, P. A.; Shtork, S. I.

    2017-09-01

    Off-design operating conditions of hydraulic turbines is hindered by pressure fluctuations in the draft tube of the turbine. A precessing helical vortex rope develops, which imperils the mechanical structure and limits the operation flexibility of hydropower station. Understanding of the underlying instabilities of precessing vortex rope at low swirl number is incomplete. In this paper flow regimes with different residual swirl is analysed, particular attention is paid to the regime with a small swirl parameter. Study defines upper and low boundaries of regime where aperiodic pressure surge is observed. Flow field at the runner exit is investigated by Laser Doppler Velocimetry and high-speed visualizations, which are complemented draft tube wall pressure measurements.

  20. Some flow phenomena in a constant area duct with a Borda type inlet including the critical region

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Simoneau, R. J.

    1978-01-01

    Mass limiting flow characteristics for a 55 L/D tube with a Borda type inlet were assessed over large ranges of temperature and pressure, using fluid nitrogen. Under certain conditions, separation and pressure drop at the inlet was sufficiently strong to permit partial vaporization and the remaining fluid flowed through the tube as if it were a free jet. An empirical relation was determined which defines conditions under which this type of flow can occur. A flow coefficient is presented which enables estimations of flow rates over the experimental range. A flow rate stagnation pressure map for selected stagnation isotherms and pressure profiles document these flow phenomena.

  1. The values of intrapleural pressure before the removal of chest tube in non-complicated pulmonary lobectomies.

    PubMed

    Refai, Majed; Brunelli, Alessandro; Varela, Gonzalo; Novoa, Nuria; Pompili, Cecilia; Jimenez, Marcelo F; Aranda, José Luis; Sabbatini, Armando

    2012-04-01

    Digitalized chest drainage systems allow for quantification of air leak and measurement of intrapleural pressure. Little is known about the value of intrapleural pressure during the postoperative phase and its role in the recovering process after pulmonary resection. The objective of this investigation was to measure the values of pleural pressure immediately before the removal of chest tube after different types of pulmonary lobectomy. Prospective observational analysis on 203 consecutive patients submitted to pulmonary lobectomy during a 12-month period at two centres. Multiple measurements were recorded in the last hour before the removal of chest tube and averaged for the analysis. All patients were seated in bed in a 45° up-right position or in a chair, had a single chest tube and were not connected to suction during the evaluation period. Analysis of variance (ANOVA) was used to assess the differences in pleural pressure between different types of lobectomies. The average maximum, minimum and differential pressures were -6.1, -19.5 and 13.3 cmH(2)O, respectively. The average pressures were similar in all types of lobectomies (ANOVA, P = 0.2) and ranged from -11 to -13 cmH(2)O, with the exception of right upper bilobectomy (-20 cmH(2)O, all P-values vs. other types of lobectomies <0.05). Similar values were also recorded for maximum pressures (range -4.4 to -8.4 cmH(2)O) and minimum pressures (-31.6 cmH(2)O vs. ranged from -15.4 to -20.5 cmH(2)O, all P-values <0.01). The average pleural pressure was not associated with FEV1 (P = 0.9), DLCO (P = 0.2) or FEV1/FVC ratio (P = 0.6), when tested with linear regression. Similarly, the average pleural pressure was similar in patients with and without COPD (-12.1 vs. -13.0 cmH(2)O, P = 0.4). The ANOVA test was used to assess differences in pressures between different lobectomies. The so-called water seal status may actually correspond to intrapleural pressures ranging from -13 to -20 cmH(2)O. Modern electronic chest drainage devices allow a stable control of the intrapleural pressure. Thus, the values found in this study may be used as target pressures for different types of lobectomies, in order to favour lung recovery after surgery.

  2. Curing A Large Composite Cylinder Without An Autoclave

    NASA Technical Reports Server (NTRS)

    Frazer, Robert E.

    1992-01-01

    Proposed technique provides application of heat and pressure to cure fiber-wound composite cylinder too large to fit in autoclave. Tube wound around cylinder applies pressure. Blanket distributes pressure. Pressure expels gas bubbles from material. Heat applied by conventional methods.

  3. CONDENSATION CAN

    DOEpatents

    Booth, E.T. Jr.; Pontius, R.B.; Jacobsohn, B.A.; Slade, C.B.

    1962-03-01

    An apparatus is designed for condensing a vapor to a solid at relatively low back pressures. The apparatus comprises a closed condensing chamber, a vapor inlet tube extending to the central region of the chamber, a co-axial tubular shield surrounding the inlet tube, means for heating the inlet tube at a point outside the condensing chamber, and means for refrigeratirg the said chamber. (AEC)

  4. End Restraints for Impact-Energy-Absorbing Tube Specimens

    NASA Technical Reports Server (NTRS)

    Farley, G. L.; Modlin, J. T.

    1985-01-01

    Inexpensive device developed that eliminates tipping problem without affecting crushing process. Device consists of soft sponge-rubber insert approximately 0.5 inches (1.3 centimeters) thick, cut to same diameter as internal diameter of tube specimen. Metal washer, slightly smaller than internal diameter of tube, placed on top of rubber insert. Screw passed through washer and rubber insert and threaded into base of test machine. As screw tightened against washer, rubber insert compressed and expands radially. Radial expansion applies pressure against internal wall of tube specimen, which provides sufficient support to tube to prevent tipping.

  5. Numerical simulation analysis of four-stage mutation of solid-liquid two-phase grinding

    NASA Astrophysics Data System (ADS)

    Li, Junye; Liu, Yang; Hou, Jikun; Hu, Jinglei; Zhang, Hengfu; Wu, Guiling

    2018-03-01

    In order to explore the numerical simulation of solid-liquid two-phase abrasive grain polishing and abrupt change tube, in this paper, the fourth order abrupt change tube was selected as the research object, using the fluid mechanics software to simulate,based on the theory of solid-liquid two-phase flow dynamics, study on the mechanism of AFM micromachining a workpiece during polishing.Analysis at different inlet pressures, the dynamic pressure distribution pipe mutant fourth order abrasive flow field, turbulence intensity, discuss the influence of the inlet pressure of different abrasive flow polishing effect.

  6. Speed control with end cushion for high speed air cylinder

    DOEpatents

    Stevens, Wayne W.; Solbrig, Charles W.

    1991-01-01

    A high speed air cylinder in which the longitudinal movement of the piston within the air cylinder tube is controlled by pressurizing the air cylinder tube on the accelerating side of the piston and releasing pressure at a controlled rate on the decelerating side of the piston. The invention also includes a method for determining the pressure required on both the accelerating and decelerating sides of the piston to move the piston with a given load through a predetermined distance at the desired velocity, bringing the piston to rest safely without piston bounce at the end of its complete stroke.

  7. Effect of swirler-mounted mixing venturi on emissions of flame-tube combustor using jet A fuel

    NASA Technical Reports Server (NTRS)

    Ercegovic, D. B.

    1979-01-01

    Six headplate modules in a flame-tube combustor were evaluated. Unburned hydrocarbons, carbon monoxide, and oxides of nitrogen were measured for three types of fuel injectors both with and without a mixing venturi. Tests were conducted using jet A fuel at an inlet pressure of 0.69 megapascal, an inlet temperature of 478 K, and an isothermal static pressure drop of 3 percent. Oxides of nitrogen were reduced by over 50 percent with a mixing venturi with no performance penalties in either other gaseous emissions or pressure drop.

  8. Free-stream temperature, density, and pressure measurements in an expansion tube flow

    NASA Technical Reports Server (NTRS)

    Haggard, K. V.

    1973-01-01

    An experimental study was conducted to determine test-flow conditions in the Langley pilot model expansion tube. Measurements of temperature, density, wall pressure, pitot pressure, and shock and interface velocities were compared with theoretical calculations based on various models of the flow cycle. The vibrational temperature and integrated density of the molecular oxygen component of the flow were measured by use of vacuum ultraviolet absorption techniques. These measurements indicate both the presence and possible degree of nonequilibrium in the flow. Data are compared with several simplified models of the flow cycle, and data trends are discussed.

  9. A novel technique for preventing skin pressure sores using a rubber tube during surgical treatment of mandibular condyle fractures.

    PubMed

    Kawase-Koga, Yoko; Mori, Yoshiyuki; Hoshi, Kazuhito; Takato, Tsuyoshi

    2013-11-01

    Craniofacial surgery occasionally results in sores and necrosis of the facial skin because of pressure from surgical instruments. During surgical treatment of mandibular condylar process fractures, the main mandibular fragment is routinely retracted downward using a wire to achieve a satisfactory anatomic reduction. This procedure may injure the facial skin. This potential complication is easily overlooked by medical staff, but it is easily preventable. We herein describe a method of using a rubber tube to avoid causing pressure sores of the facial skin during surgical treatment of mandibular condylar process fractures.

  10. Measurement of unsteady airflow velocity at nozzle outlet

    NASA Astrophysics Data System (ADS)

    Pyszko, René; Machů, Mário

    2017-09-01

    The paper deals with a method of measuring and evaluating the cooling air flow velocity at the outlet of the flat nozzle for cooling a rolled steel product. The selected properties of the Prandtl and Pitot sensing tubes were measured and compared. A Pitot tube was used for operational measurements of unsteady dynamic pressure of the air flowing from nozzles to abtain the flow velocity. The article also discusses the effects of air temperature, pressure and relative air humidity on air density, as well as the influence of dynamic pressure filtering on the error of averaged velocity.

  11. Gas propagation in a liquid helium cooled vacuum tube following a sudden vacuum loss

    NASA Astrophysics Data System (ADS)

    Dhuley, Ram C.

    This dissertation describes the propagation of near atmospheric nitrogen gas that rushes into a liquid helium cooled vacuum tube after the tube suddenly loses vacuum. The loss-of-vacuum scenario resembles accidental venting of atmospheric air to the beam-line of a superconducting radio frequency particle accelerator and is investigated to understand how in the presence of condensation, the in-flowing air will propagate in such geometry. In a series of controlled experiments, room temperature nitrogen gas (a substitute for air) at a variety of mass flow rates was vented to a high vacuum tube immersed in a bath of liquid helium. Pressure probes and thermometers installed on the tube along its length measured respectively the tube pressure and tube wall temperature rise due to gas flooding and condensation. At high mass in-flow rates a gas front propagated down the vacuum tube but with a continuously decreasing speed. Regression analysis of the measured front arrival times indicates that the speed decreases nearly exponentially with the travel length. At low enough mass in-flow rates, no front propagated in the vacuum tube. Instead, the in-flowing gas steadily condensed over a short section of the tube near its entrance and the front appeared to `freeze-out'. An analytical expression is derived for gas front propagation speed in a vacuum tube in the presence of condensation. The analytical model qualitatively explains the front deceleration and flow freeze-out. The model is then simplified and supplemented with condensation heat/mass transfer data to again find the front to decelerate exponentially while going away from the tube entrance. Within the experimental and procedural uncertainty, the exponential decay length-scales obtained from the front arrival time regression and from the simplified model agree.

  12. Thermal design, rating and second law analysis of shell and tube condensers based on Taguchi optimization for waste heat recovery based thermal desalination plants

    NASA Astrophysics Data System (ADS)

    Chandrakanth, Balaji; Venkatesan, G; Prakash Kumar, L. S. S; Jalihal, Purnima; Iniyan, S

    2018-03-01

    The present work discusses the design and selection of a shell and tube condenser used in Low Temperature Thermal Desalination (LTTD). To optimize the key geometrical and process parameters of the condenser with multiple parameters and levels, a design of an experiment approach using Taguchi method was chosen. An orthogonal array (OA) of 25 designs was selected for this study. The condenser was designed, analysed using HTRI software and the heat transfer area with respective tube side pressure drop were computed using the same, as these two objective functions determine the capital and running cost of the condenser. There was a complex trade off between the heat transfer area and pressure drop in the analysis, however second law analysis was worked out for determining the optimal heat transfer area vs pressure drop for condensing the required heat load.

  13. Neutron source, linear-accelerator fuel enricher and regenerator and associated methods

    DOEpatents

    Steinberg, Meyer; Powell, James R.; Takahashi, Hiroshi; Grand, Pierre; Kouts, Herbert

    1982-01-01

    A device for producing fissile material inside of fabricated nuclear elements so that they can be used to produce power in nuclear power reactors. Fuel elements, for example, of a LWR are placed in pressure tubes in a vessel surrounding a liquid lead-bismuth flowing columnar target. A linear-accelerator proton beam enters the side of the vessel and impinges on the dispersed liquid lead-bismuth columns and produces neutrons which radiate through the surrounding pressure tube assembly or blanket containing the nuclear fuel elements. These neutrons are absorbed by the natural fertile uranium-238 elements and are transformed to fissile plutonium-239. The fertile fuel is thus enriched in fissile material to a concentration whereby they can be used in power reactors. After use in the power reactors, dispensed depleted fuel elements can be reinserted into the pressure tubes surrounding the target and the nuclear fuel regenerated for further burning in the power reactor.

  14. The Effect of Turbulence on the Drag of Flat Plates

    NASA Technical Reports Server (NTRS)

    Schubauer, G B; Dryden, H L

    1937-01-01

    in determining the effect of turbulence on the forces exerted on bodies in the air stream of a wind tunnel, it is commonly assumed that the indications of the standard Pitot-static tube used to determine the air speed are not dependent on the turbulence. To investigate the truth of this assumption, the drag of a normally exposed flat plate, the difference in pressure between the front and rear of a thin circular disk, the rate of rotation of a vane anemometer, and the pressure developed by a standard Pitot-static tube were measured in an air stream for several conditions of turbulence. The results may be interpreted as indicating that there is no appreciable effect of turbulence on the vane anemometer and the standard pitot-static tube, but that there is small effect on the drag of a flat plate and the pressure difference between front and rear of a disk.

  15. Internally Mounting Strain Gages

    NASA Technical Reports Server (NTRS)

    Jett, J. R., Jr.

    1984-01-01

    Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.

  16. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOEpatents

    McDermott, D.J.; Schrader, K.J.; Schulz, T.L.

    1994-05-03

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  17. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOEpatents

    McDermott, Daniel J.; Schrader, Kenneth J.; Schulz, Terry L.

    1994-01-01

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  18. Overall heat transfer coefficient and pressure drop in a typical tubular exchanger employing alumina nano-fluid as the tube side hot fluid

    NASA Astrophysics Data System (ADS)

    Kabeel, A. E.; Abdelgaied, Mohamed

    2016-08-01

    Nano-fluids are used to improve the heat transfer rates in heat exchangers, especially; the shell-and-tube heat exchanger that is considered one of the most important types of heat exchangers. In the present study, an experimental loop is constructed to study the thermal characteristics of the shell-and-tube heat exchanger; at different concentrations of Al2O3 nonmetallic particles (0.0, 2, 4, and 6 %). This material concentrations is by volume concentrations in pure water as a base fluid. The effects of nano-fluid concentrations on the performance of shell and tube heat exchanger have been conducted based on the overall heat transfer coefficient, the friction factor, the pressure drop in tube side, and the entropy generation rate. The experimental results show that; the highest heat transfer coefficient is obtained at a nano-fluid concentration of 4 % of the shell side. In shell side the maximum percentage increase in the overall heat transfer coefficient has reached 29.8 % for a nano-fluid concentration of 4 %, relative to the case of the base fluid (water) at the same tube side Reynolds number. However; in the tube side the maximum relative increase in pressure drop has recorded the values of 12, 28 and 48 % for a nano-material concentration of 2, 4 and 6 %, respectively, relative to the case without nano-fluid, at an approximate value of 56,000 for Reynolds number. The entropy generation reduces with increasing the nonmetallic particle volume fraction of the same flow rates. For increase the nonmetallic particle volume fraction from 0.0 to 6 % the rate of entropy generation decrease by 10 %.

  19. Method for estimating off-axis pulse tube losses

    NASA Astrophysics Data System (ADS)

    Fang, T.; Mulcahey, T. I.; Taylor, R. P.; Spoor, P. S.; Conrad, T. J.; Ghiaasiaan, S. M.

    2017-12-01

    Some Stirling-type pulse tube cryocoolers (PTCs) exhibit sensitivity to gravitational orientation and often exhibit significant cooling performance losses unless situated with the cold end pointing downward. Prior investigations have indicated that some coolers exhibit sensitivity while others do not; however, a reliable method of predicting the level of sensitivity during the design process has not been developed. In this study, we present a relationship that estimates an upper limit to gravitationally induced losses as a function of the dimensionless pulse tube convection number (NPTC) that can be used to ensure that a PTC would remain functional at adverse static tilt conditions. The empirical relationship is based on experimental data as well as experimentally validated 3-D computational fluid dynamics simulations that examine the effects of frequency, mass flow rate, pressure ratio, mass-pressure phase difference, hot and cold end temperatures, and static tilt angle. The validation of the computational model is based on experimental data collected from six commercial pulse tube cryocoolers. The simulation results are obtained from component-level models of the pulse tube and heat exchangers. Parameter ranges covered in component level simulations are 0-180° for tilt angle, 4-8 for length to diameter ratios, 4-80 K cold tip temperatures, -30° to +30° for mass flow to pressure phase angles, and 25-60 Hz operating frequencies. Simulation results and experimental data are aggregated to yield the relationship between inclined PTC performance and pulse tube convection numbers. The results indicate that the pulse tube convection number can be used as an order of magnitude indicator of the orientation sensitivity, but CFD simulations should be used to calculate the change in energy flow more accurately.

  20. Wall pressure measurements of flooding in vertical countercurrent annular air–water flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choutapalli, I., Vierow, K.

    2010-01-01

    An experimental study of flooding in countercurrent air-water annular flow in a large diameter vertical tube using wall pressure measurements is described in this paper. Axial pressure profiles along the length of the test section were measured up to and after flooding using fast response pressure transducers for three representative liquid flow rates representing a wide range of liquid Reynolds numbers (ReL = 4Γ/μ; Γ is the liquid mass flow rate per unit perimeter; μ is the dynamic viscosity) from 3341 to 19,048. The results show that flooding in large diameter tubes cannot be initiated near the air outlet andmore » is only initiated near the air inlet. Fourier analysis of the wall pressure measurements shows that up to the point of flooding, there is no dominant wave frequency but rather a band of frequencies encompassing both the low frequency and the broad band that are responsible for flooding. The data indicates that flooding in large diameter vertical tubes may be caused by the constructive superposition of a plurality of waves rather than the action of a single large-amplitude wave.« less

  1. Condensation Heat-Transfer Measurements of Refrigerants on Externally Enhanced Tubes.

    DTIC Science & Technology

    1987-06-01

    Pf Density of condensate at Tf (kgjm3 ) e Insulated angle em Rotation angle of normal to fin surface Of Surface tension of condensate (N/m) a Nusselt ...reported data for the condensation of steam at near atmospheric pressure on smooth tubes and roped tubes with and without a helical , external wrap of...Their model, a Nusselt -type equation based on the equivalent diameter of the finned tube, lives the average condensing coefficient by the following

  2. [Heated humidification during CPAP with and without tube insulation].

    PubMed

    Rühle, K-H; Domanski, U; Schröder, M; Franke, K J; Nilius, G

    2010-05-01

    Patients with obstructive sleep apnoea syndrome (OSAS) under continuous positive pressure (CPAP) often complain about drying-up of the throat and nasal mucosa. In many cases the problem can be eliminated with a heated humidifier (WLB). Especially in a cold environment condensation forming on cooling of the air in the tube and the mask can be observed. To avoid this, some patients use an insulating tube covering. We investigated the effect of temperature (T) and relative humidity (rH) of the environment, the ventilation pressure, mask leaks, insulation of tubing on the T and rH% of the delivered air at the end of the tube or in the mask in OSAS patients. All measurements were performed with a conventional WLB (S8, Resmed Fa) and a temperature and humidity sensor (Fa Testo, Lenzkirch). 8 patients with OSAS were examined during the day at a room temperature of 16.4 degrees C. The temperature at the outlet of the WLB increased with a higher ambient temperature. Through isolation with a hose cover the temperature drop in the tube was reduced by 2.3 degrees C. By tube insulation a mean increase in temperature between 1.6 and 1.0 C during normal breathing in dependence on the leakage flow in the mask was found. Due to additional insulation with a tube cover the mask temperature can be increased, albeit slightly, and the formation of condensation is reduced.

  3. Evaluation of runner cone extension to dampen pressure pulsations in a Francis model turbine

    NASA Astrophysics Data System (ADS)

    Gogstad, Peter Joachim; Dahlhaug, Ole Gunnar

    2016-11-01

    Today's energy market has a high demand of flexibility due to introduction of other intermittent renewables as wind and solar. To ensure a steady power supply, hydro turbines are often forced to operate more at part load conditions. Originally, turbines were built for steady operation around the best efficiency point. The demand of flexibility, combined with old designs has showed an increase in turbines having problems with hydrodynamic instabilities such as pressure pulsations. Different methods have been investigated to mitigate pressure pulsations. Air injection shows a significant reduction of pressure pulsation amplitudes. However, installation of air injection requires extra piping and a compressor. Investigation of other methods such as shaft extension shows promising results for some operational points, but may significantly reduce the efficiency of the turbine at other operational points. The installation of an extension of the runner cone has been investigated at NTNU by Vekve in 2004. This has resulted in a cylindrical extension at Litjfossen Power Plant in Norway, where the bolt suffered mechanical failure. This indicates high amplitude pressure pulsations in the draft tube centre. The high pressure pulsation amplitudes are believed to be related to high tangential velocity in the draft tube. The mentioned runner cone extension has further been developed to a freely rotating extension. The objective is to reduce the tangential velocity in the draft tube and thereby the pressure pulsation amplitudes.

  4. Design of a Two-Stage Light Gas Gun for Muzzle Velocities of 10 - 11 kms

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.

    2016-01-01

    Space debris poses a major risk to spacecraft. In low earth orbit, impact velocities can be 10 11 kms and as high as 15 kms. For debris shield design, it would be desirable to be able to launch controlled shape projectiles to these velocities. The design of the proposed 10 11 kmsec gun uses, as a starting point, the Ames 1.280.22 two stage gun, which has achieved muzzle velocities of 10 11.3 kmsec. That gun is scaled up to a 0.3125 launch tube diameter. The gun is then optimized with respect to maximum pressures by varying the pump tube length to diameter ratio (LD), the piston mass and the hydrogen pressure. A pump tube LD of 36.4 is selected giving the best overall performance. Piezometric ratios for the optimized guns are found to be 2.3, much more favorable than for more traditional two stage light gas guns, which range from 4 to 6. The maximum powder chamber pressures are 20 to 30 ksi. To reduce maximum pressures, the desirable range of the included angle of the cone of the high pressure coupling is found to be 7.3 to 14.6 degrees. Lowering the break valve rupture pressure is found to lower the maximum projectile base pressure, but to raise the maximum gun pressure. For the optimized gun with a pump tube LD of 36.4, increasing the muzzle velocity by decreasing the projectile mass and increasing the powder loads is studied. It appears that saboted spheres could be launched to 10.25 and possibly as high as 10.7 10.8 kmsec, and that disc-like plastic models could be launched to 11.05 kms. The use of a tantalum liner to greatly reduce bore erosion and increase muzzle velocity is discussed. With a tantalum liner, CFD code calculations predict muzzle velocities as high as 12 to 13 kms.

  5. Steady finite-Reynolds-number flows in three-dimensional collapsible tubes

    NASA Astrophysics Data System (ADS)

    Hazel, Andrew L.; Heil, Matthias

    2003-07-01

    A fully coupled finite-element method is used to investigate the steady flow of a viscous fluid through a thin-walled elastic tube mounted between two rigid tubes. The steady three-dimensional Navier Stokes equations are solved simultaneously with the equations of geometrically nonlinear Kirchhoff Love shell theory. If the transmural (internal minus external) pressure acting on the tube is sufficiently negative then the tube buckles non-axisymmetrically and the subsequent large deformations lead to a strong interaction between the fluid and solid mechanics. The main effect of fluid inertia on the macroscopic behaviour of the system is due to the Bernoulli effect, which induces an additional local pressure drop when the tube buckles and its cross-sectional area is reduced. Thus, the tube collapses more strongly than it would in the absence of fluid inertia. Typical tube shapes and flow fields are presented. In strongly collapsed tubes, at finite values of the Reynolds number, two ’jets‘ develop downstream of the region of strongest collapse and persist for considerable axial distances. For sufficiently high values of the Reynolds number, these jets impact upon the sidewalls and spread azimuthally. The consequent azimuthal transport of momentum dramatically changes the axial velocity profiles, which become approximately uTheta-shaped when the flow enters the rigid downstream pipe. Further convection of momentum causes the development of a ring-shaped velocity profile before the ultimate return to a parabolic profile far downstream.

  6. Effects of Increasing Airway Pressures on the Pressure of the Endotracheal Tube Cuff During Pelvic Laparoscopic Surgery.

    PubMed

    Rosero, Eric B; Ozayar, Esra; Eslava-Schmalbach, Javier; Minhajuddin, Abu; Joshi, Girish P

    2017-11-17

    Tracheal tube cuff pressures exceeding the perfusion pressures of the tracheal mucosa have been associated with complications such as sore throat, tracheal mucosa ulcers, tracheal rupture, and subglottic stenosis. Despite appropriate inflation, many factors can increase the tracheal cuff pressure during mechanical ventilation. This prospective observational cohort study was designed to test the hypothesis that during a clinical model of decreasing respiratory compliance, the pressure within the endotracheal tube cuff will rise in direct relationship to increases in the airway pressures. Twenty-eight adult obese patients (BMI ≥30 kg/m) scheduled for elective laparoscopic gynecologic procedures were enrolled. All patients received general anesthesia utilizing endotracheal tubes with low-pressure high-volume cuffs. After baseline adjustment of the cuff pressure to 25 cm H2O, the airway pressures and endotracheal cuff pressures were continuously measured using pressure transducers connected to the anesthesia circuit and cuff pilot, respectively. Data on cuff and airway pressures, mechanical ventilation parameters, intraabdominal pressures, and degree of surgical table inclination were collected throughout the anesthetic procedure. General linear regression models with fixed and random effects were fit to assess the effect of increases in airway pressures on cuff pressure, after adjusting for covariates and the clustered structure of the data. The mean (standard deviation) age and body mass index were 42.2 (8.8) years and 37.7 (5.1) kg/m, respectively. After tracheal intubation, the cuffs were overinflated (ie, intracuff pressures >30 cm H2O) in 89% of patients. The cuff pressures significantly changed after concomitant variations in the airway pressures from a mean (standard error) value of 29.6 (1.30) cm H2O before peritoneal insufflations, to 35.6 (0.68) cm H2O after peritoneal insufflation, and to 27.8 (0.79) cm H2O after peritoneal deflation (P < .0001). The multilevel mixed regression models revealed that after controlling for clustering of the data (at the patient and study phase levels) and covariates, increased peak airway pressures were significantly associated with increased pressures within the endotracheal cuff (coefficient [95% confidence interval], 0.25 [0.14-0.36]; P < .0001). Other variables associated with increasing endotracheal cuff pressure included degree of surgical table inclination (0.08 [0.04-0.12]; P = .0003) and I:E ratio of 1:1 (4.47 [2.10-6.83]; P = .0002). This clinical model of decreased respiratory compliance in mechanically ventilated patients reveals that the pressure within the endotracheal cuff significantly changes in direct relation to changes in the airway pressures. This finding may have clinical relevance in patients requiring prolonged use of high airway pressures.

  7. Three-phase flow? Consider helical-coil heat exchangers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haraburda, S.S.

    1995-07-01

    In recent years, chemical process plants are increasingly encountering processes that require heat exchange in three-phase fluids. A typical application, for example, is heating liquids containing solid catalyst particles and non-condensable gases. Heat exchangers designed for three-phase flow generally have tubes with large diameters (typically greater than two inches), because solids can build-up inside the tube and lead to plugging. At the same time, in order to keep heat-transfer coefficients high, the velocity of the process fluid within the tube should also be high. As a result, heat exchangers for three-phase flow may require less than five tubes -- eachmore » having a required linear length that could exceed several hundred feet. Given these limitations, it is obvious that a basic shell-and-tube heat exchanger is not the most practical solution for this purpose. An alternative for three-phase flow is a helical-coil heat exchanger. The helical-coil units offer a number of advantages, including perpendicular, counter-current flow and flexible overall dimensions for the exchanger itself. The paper presents equations for: calculating the tube-side heat-transfer coefficient; calculating the shell-side heat-transfer coefficient; calculating the heat-exchanger size; calculating the tube-side pressure drop; and calculating shell-side pressure-drop.« less

  8. The effect of continuous positive airway pressure on middle ear pressure.

    PubMed

    Lin, Fred Y; Gurgel, Richard K; Popelka, Gerald R; Capasso, Robson

    2012-03-01

    While continuous positive airway pressure (CPAP) is commonly used for obstructive sleep apnea treatment, its effect on middle ear pressure is unknown. The purpose of this study was to measure the effect of CPAP on middle ear pressure and describe the correlation between CPAP levels and middle ear pressures. Retrospective review of normal tympanometry values and a prospective cohort evaluation of subjects' tympanometric values while using CPAP at distinct pressure levels. A total of 3,066 tympanograms were evaluated to determine the normal range of middle ear pressures. Ten subjects with no known history of eustachian tube dysfunction or obstructive sleep apnea had standard tympanometry measurements while wearing a CPAP device. Measurements were taken at baseline and with CPAP air pressures of 0, 5, 10, and 15 cm H(2)O. The percentage of normal control patients with middle ear pressures above 40 daPa was 0.03%. In the study population, prior to a swallowing maneuver to open the eustachian tube, average middle ear pressures were 21.67 daPa, 22.63 daPa, 20.42, daPa, and 21.58 daPa with CPAP pressures of 0, 5, 10, and 15 cm H(2) 0, respectively. After swallowing, average middle ear air pressures were 18.83 daPa, 46.75 daPa, 82.17 daPa, and 129.17 daPa with CPAP pressures of 0, 5, 10, and 15 cm H(2)0, respectively. The postswallow Pearson correlation coefficient correlating CPAP and middle ear pressures was 0.783 (P < 0.001). Middle ear air pressure is directly proportional to CPAP air pressure in subjects with normal eustachian tube function. Middle ear pressure reaches supraphysiologic levels at even minimal CPAP levels. Although further investigation is necessary, there may be otologic implications for patients who are chronically CPAP dependent. These findings may also influence the perioperative practice of otologic and skull base surgeons. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  9. DIRECT-CYCLE, BOILING-WATER NUCLEAR REACTOR

    DOEpatents

    Harrer, J.M.; Fromm, L.W. Jr.; Kolba, V.M.

    1962-08-14

    A direct-cycle boiling-water nuclear reactor is described that employs a closed vessel and a plurality of fuel assemblies, each comprising an outer tube closed at its lower end, an inner tube, fuel rods in the space between the tubes and within the inner tube. A body of water lying within the pressure vessel and outside the fuel assemblies is converted to saturated steam, which enters each fuel assembly at the top and is converted to superheated steam in the fuel assembly while it is passing therethrough first downward through the space between the inner and outer tubes of the fuel assembly and then upward through the inner tube. (AEC)

  10. Detonation mode and frequency analysis under high loss conditions for stoichiometric propane-oxygen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, Scott I.; Lee, Bok Jik; Shepherd, Joseph E.

    In this paper, the propagation characteristics of galloping detonations were quantified with a high-time-resolution velocity diagnostic. Combustion waves were initiated in 30-m lengths of 4.1-mm inner diameter transparent tubing filled with stoichiometric propane–oxygen mixtures. Chemiluminescence from the resulting waves was imaged to determine the luminous wave front position and velocity every 83.3 μ. As the mixture initial pressure was decreased from 20 to 7 kPa, the wave was observed to become increasingly unsteady and transition from steady detonation to a galloping detonation. While wave velocities averaged over the full tube length smoothly decreased with initial pressure down to half ofmore » the Chapman–Jouguet detonation velocity (D CJ) at the quenching limit, the actual propagation mechanism was seen to be a galloping wave with a cycle period of approximately 1.0 ms, corresponding to a cycle length of 1.3–2.0 m or 317–488 tube diameters depending on the average wave speed. The long test section length of 7300 tube diameters allowed observation of up to 20 galloping cycles, allowing for statistical analysis of the wave dynamics. In the galloping regime, a bimodal velocity distribution was observed with peaks centered near 0.4 D CJ and 0.95 D CJ. Decreasing initial pressure increasingly favored the low velocity mode. Galloping frequencies ranged from 0.8 to 1.0 kHz and were insensitive to initial mixture pressure. Wave deflagration-to-detonation transition and detonation failure trajectories were found to be repeatable in a given test and also across different initial mixture pressures. The temporal duration of wave dwell at the low and high velocity modes during galloping was also quantified. It was found that the mean wave dwell duration in the low velocity mode was a weak function of initial mixture pressure, while the mean dwell time in the high velocity mode depended exponentially on initial mixture pressure. Analysis of the velocity histories using dynamical systems ideas demonstrated trajectories that varied from stable to limit cycles to aperiodic motion with decreasing initial pressure. Finally, the results indicate that galloping detonation is a persistent phenomenon at long tube lengths.« less

  11. Detonation mode and frequency analysis under high loss conditions for stoichiometric propane-oxygen

    DOE PAGES

    Jackson, Scott I.; Lee, Bok Jik; Shepherd, Joseph E.

    2016-03-24

    In this paper, the propagation characteristics of galloping detonations were quantified with a high-time-resolution velocity diagnostic. Combustion waves were initiated in 30-m lengths of 4.1-mm inner diameter transparent tubing filled with stoichiometric propane–oxygen mixtures. Chemiluminescence from the resulting waves was imaged to determine the luminous wave front position and velocity every 83.3 μ. As the mixture initial pressure was decreased from 20 to 7 kPa, the wave was observed to become increasingly unsteady and transition from steady detonation to a galloping detonation. While wave velocities averaged over the full tube length smoothly decreased with initial pressure down to half ofmore » the Chapman–Jouguet detonation velocity (D CJ) at the quenching limit, the actual propagation mechanism was seen to be a galloping wave with a cycle period of approximately 1.0 ms, corresponding to a cycle length of 1.3–2.0 m or 317–488 tube diameters depending on the average wave speed. The long test section length of 7300 tube diameters allowed observation of up to 20 galloping cycles, allowing for statistical analysis of the wave dynamics. In the galloping regime, a bimodal velocity distribution was observed with peaks centered near 0.4 D CJ and 0.95 D CJ. Decreasing initial pressure increasingly favored the low velocity mode. Galloping frequencies ranged from 0.8 to 1.0 kHz and were insensitive to initial mixture pressure. Wave deflagration-to-detonation transition and detonation failure trajectories were found to be repeatable in a given test and also across different initial mixture pressures. The temporal duration of wave dwell at the low and high velocity modes during galloping was also quantified. It was found that the mean wave dwell duration in the low velocity mode was a weak function of initial mixture pressure, while the mean dwell time in the high velocity mode depended exponentially on initial mixture pressure. Analysis of the velocity histories using dynamical systems ideas demonstrated trajectories that varied from stable to limit cycles to aperiodic motion with decreasing initial pressure. Finally, the results indicate that galloping detonation is a persistent phenomenon at long tube lengths.« less

  12. Laboratory experiments on fragmentation of highly-viscous bubbly syrup

    NASA Astrophysics Data System (ADS)

    Kurihara, H.; Kameda, M.; Ichihara, M.

    2006-12-01

    Fragmentation of vesicular magma by rapid decompression is a key process in explosive eruptions. To determine the fragmentation criteria, we carried out laboratory experiments on magma fragmentation using analogous materials. We used commercial syrup as an analogous material of magma, because the viscosity was widely altered by adding or subtracting water contents in the syrup. We made the bubbly syrup by adding hydrogen peroxide with manganese oxide in the syrup. The amount of hydrogen peroxide is proportional to the gas volume fraction in the syrup. We measured the rheological properties of the syrup. Zero shear viscosity η was measured by a rotating viscometer and a fiber elongation technique. Glass transition temperature was measured by differential scanning calorimetry. The measured data indicated that the temperature dependence of viscosity was described well using Williams-Landel-Ferry (WLF) equation. The solid content of syrup alters the viscosity as well as the glass transition temperature, though it may hardly affect the rigidity μ, which was measured by ultrasonic test in our previous work. We used a pressurized vertical tube with a large vacuum vessel to apply the rapid decompression on the material. An acrylic container, filled with the bubbly syrup, was placed in the bottom of the pressurized tube. By rupturing the diaphragms inserted between the tube and the vacuum vessel, the bubbly syrup is rapidly decompressed due to expansion of the pressurized gas in the tube. A high-speed video camera was used to obtain sequential images of the materials. Pressure transducers were mounted on the sidewall of the tube and the bottom of the container. The initial pressure was varied from 1 MPa to 5 MPa. The gas-volume fraction of the syrup under pressure was fixed as 2 % to 20%. The viscosity varied from 105 Pa·s to 108 Pa·s. We successfully observed three principal behaviors using the present analogous material; brittle fragmentation, partial fracture and ductile expansion without crack initiation. From all the experimental data, in conclusion, the fragmentation is observed when the pressure drop Δ p reaches a critical value within the order of relaxation time of syrup, which is defined as η/μ. Simultaneously, the initial gas volume fraction should be larger than a critical value, which decreases as the initial high-pressure is larger.

  13. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  14. Arrangement for measuring the field angle of a magnetic field as a function of axial position within a magnet bore tube

    DOEpatents

    Pidcoe, Stephen V.; Zink, Roger A.; Boroski, William N.; McCaw, William R.

    1993-01-01

    An arrangement for measuring the field angle of a magnetic field as a function of axial position within a magnet bore tube of a magnet such as is used with the Superconducting Super Collider (SSC). The arrangement includes a magnetic field alignment gauge that is carried through the magnet bore tube by a positioning shuttle in predetermined increments. The positioning shuttle includes an extensible body assembly which is actuated by an internal piston arrangement. A pair of spaced inflatable cuffs are carried by the body assembly and are selectively actuated in cooperation with pressurizing of the piston to selectively drive the positioning shuttle in an axial direction. Control of the shuttle is provided by programmed electronic computer means located exteriorly of the bore tube and which controls valves provided pressurized fluid to the inflatable cuss and the piston arrangement.

  15. Enhanced methods for operating refueling station tube-trailers to reduce refueling cost

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elgowainy, Amgad; Reddi, Krishna

    A method and apparatus are provided for operating a refueling station including source tube-trailers and at least one compressor to reduce refueling cost. The refueling station includes a gaseous fuel supply source including a plurality of tanks on a tube trailer coupled to a first control unit, and high pressure buffer storage having predefined capacity coupled to a second control unit and the first tanks by a pressure control valve and the first control unit, and at least one compressor. The refueling station is operated at different modes depending on a state of the refueling station at the beginning ofmore » each operational mode. The refueling system is assessed at the end of each operational mode to identify the state of the system and select a next mode of operation. The operational modes include consolidating hydrogen, or any gaseous fuel, within the tubes mounted on the trailer.« less

  16. F-16XL ship #1 wing close-up showing boundary layer detection Preston tubes

    NASA Technical Reports Server (NTRS)

    1995-01-01

    This photo shows the boundary layer Preston tubes mounted on the left wing of NASA's single-seat F-16XL (ship #1) used for the Cranked-Arrow Wing Aerodynamic Project (CAWAP) at Dryden Flight Research Center, Edwards, California. The modified airplane features a delta 'cranked-arrow' wing with strips of tubing along the leading edge to the trailing edge to sense static on the wing and obtain pressure distribution data. The right wing receives data on pressure distribution and the left wing has three types of instrumentation - preston tubes to measure local skin friction, boundary layer rakes to measure boundary layer profiles (the layer where the air interacts with the surfaces of a moving aircraft), and hot films to determine boundary layer transition locations. The first flight of CAWAP occurred on November 21, 1995, and the test program ended in April 1996.

  17. AFRL Ludwieg Tube Initial Performance

    DTIC Science & Technology

    2017-11-01

    Nov 2016 14. ABSTRACT The Air Force Research Laboratory has developed and constructed a Ludwieg tube wind tunnel for hypersonic experimental ...Ludwieg tube wind tunnel for hypersonic experimental research. This wind tunnel is now operational and its initial performance has been...opening and the first expansion wave reflection was 100 ms, as expected. About 80 ms of quasi -steady pressure was obtained after the valve-opening

  18. Adjustable Pitot Probe

    NASA Technical Reports Server (NTRS)

    Ashby, George C., Jr.; Robbins, W. Eugene; Horsley, Lewis A.

    1991-01-01

    Probe readily positionable in core of uniform flow in hypersonic wind tunnel. Formed of pair of mating cylindrical housings: transducer housing and pitot-tube housing. Pitot tube supported by adjustable wedge fairing attached to top of pitot-tube housing with semicircular foot. Probe adjusted both radially and circumferentially. In addition, pressure-sensing transducer cooled internally by water or other cooling fluid passing through annulus of cooling system.

  19. Scramjet test flow reconstruction for a large-scale expansion tube, Part 2: axisymmetric CFD analysis

    NASA Astrophysics Data System (ADS)

    Gildfind, D. E.; Jacobs, P. A.; Morgan, R. G.; Chan, W. Y. K.; Gollan, R. J.

    2018-07-01

    This paper presents the second part of a study aiming to accurately characterise a Mach 10 scramjet test flow generated using a large free-piston-driven expansion tube. Part 1 described the experimental set-up, the quasi-one-dimensional simulation of the full facility, and the hybrid analysis technique used to compute the nozzle exit test flow properties. The second stage of the hybrid analysis applies the computed 1-D shock tube flow history as an inflow to a high-fidelity two-dimensional-axisymmetric analysis of the acceleration tube. The acceleration tube exit flow history is then applied as an inflow to a further refined axisymmetric nozzle model, providing the final nozzle exit test flow properties and thereby completing the analysis. This paper presents the results of the axisymmetric analyses. These simulations are shown to closely reproduce experimentally measured shock speeds and acceleration tube static pressure histories, as well as nozzle centreline static and impact pressure histories. The hybrid scheme less successfully predicts the diameter of the core test flow; however, this property is readily measured through experimental pitot surveys. In combination, the full test flow history can be accurately determined.

  20. Crashworthiness of Aluminium Tubes; Part 1: Hydroforming at Different Corner-Fill Radii and End Feeding Levels

    NASA Astrophysics Data System (ADS)

    D'Amours, Guillaume; Rahem, Ahmed; Williams, Bruce; Worswick, Michael; Mayer, Robert

    2007-05-01

    The automotive industry, with an increasing demand to reduce vehicle weight through the adoption of lightweight materials, requires a search of efficient methods that suit these materials. One attractive concept is to use hydroforming of aluminium tubes. By using FE simulations, the process can be optimized to reduce the risk for failure while maintaining energy absorption and component integrity under crash conditions. It is important to capture the level of residual ductility after forming to allow proper design for crashworthiness. This paper presents numerical and experimental studies that have been carried out for high pressure hydroforming operations to study the influence of the tube corner radius, end feeding, material thinning, and work hardening in 76.2 mm diameter, 3 mm wall thickness AA5754 aluminium alloy tube. End feeding was used to increase the formability of the tubes. The influence of the end feed displacement versus tube forming pressure schedule was studied to optimize the forming process operation to reduce thinning. Validation of the numerical simulations was performed by comparison of the predicted strain distributions and thinning, with measured quantities. The effect of element formulation (thin shell versus solid elements) was also considered in the models.

  1. Numerical study of the influence of dielectric tube on propagation of atmospheric pressure plasma jet based on coplanar dielectric barrier discharge

    NASA Astrophysics Data System (ADS)

    Haixin, HU; Feng, HE; Ping, ZHU; Jiting, OUYANG

    2018-05-01

    A 2D fluid model was employed to simulate the influence of dielectric on the propagation of atmospheric pressure helium plasma jet based on coplanar dielectric barrier discharge (DBD). The spatio-temporal distributions of electron density, ionization rate, electrical field, spatial charge and the spatial structure were obtained for different dielectric tubes that limit the helium flow. The results show that the change of the relative permittivity of the dielectric tube where the plasma jet travels inside has no influence on the formation of DBD itself, but has great impact on the jet propagation. The velocity of the plasma jet changes drastically when the jet passes from a tube of higher permittivity to one of lower permittivity, resulting in an increase in jet length, ionization rate and electric field, as well as a change in the distribution of space charges and discharge states. The radius of the dielectric tube has a great influence on the ring-shaped or solid bullet structure. These results can well explain the behavior of the plasma jet from the dielectric tube into the ambient air and the hollow bullet in experiments.

  2. Leakage of fluid in different types of tracheal tubes.

    PubMed

    Winklmaier, U; Wüst, K; Schiller, S; Wallner, F

    2006-10-01

    The aim of this study was to evaluate leakage of liquids, i.e., water and saliva, past low-pressure cuffs of tracheostomy tubes. Three different types of tracheostomy tubes, TRACOE vario (TRACOE Medical GmbH, Germany), Rüsch Ultra-Tracheoflex (Rüsch GmbH, Germany), and Portex Blue Line Ultra (Smiths Medical, UK) were tested in isolated pig tracheas. Sixty samples (10 tubes each of 7- and 8-mm inner diameter of each type) were used. Four different experiments were devised: type 1 (water and artificial ventilation), type 2 (water and no artificial ventilation), type 3 (saliva and artificial ventilation), and type 4 (saliva and no artificial ventilation). Six milliliters of water or artificial saliva were infused over the cuff and the volume of fluid that leaked past the cuff was measured after 5, 10, and 15 min. Intracuff pressure was also measured three times. The saliva experiments resulted in less leakage than the water experiments. Leakage after treatment with water or artificial saliva is higher without artificial ventilation than with ventilation. The amount of leakage among the tubes with respect to manufacturer showed statistically significant results. However, there were no differences among tracheostomy tubes with respect to internal diameter.

  3. Scramjet test flow reconstruction for a large-scale expansion tube, Part 2: axisymmetric CFD analysis

    NASA Astrophysics Data System (ADS)

    Gildfind, D. E.; Jacobs, P. A.; Morgan, R. G.; Chan, W. Y. K.; Gollan, R. J.

    2017-11-01

    This paper presents the second part of a study aiming to accurately characterise a Mach 10 scramjet test flow generated using a large free-piston-driven expansion tube. Part 1 described the experimental set-up, the quasi-one-dimensional simulation of the full facility, and the hybrid analysis technique used to compute the nozzle exit test flow properties. The second stage of the hybrid analysis applies the computed 1-D shock tube flow history as an inflow to a high-fidelity two-dimensional-axisymmetric analysis of the acceleration tube. The acceleration tube exit flow history is then applied as an inflow to a further refined axisymmetric nozzle model, providing the final nozzle exit test flow properties and thereby completing the analysis. This paper presents the results of the axisymmetric analyses. These simulations are shown to closely reproduce experimentally measured shock speeds and acceleration tube static pressure histories, as well as nozzle centreline static and impact pressure histories. The hybrid scheme less successfully predicts the diameter of the core test flow; however, this property is readily measured through experimental pitot surveys. In combination, the full test flow history can be accurately determined.

  4. Creeping gaseous flows through elastic tube and annulus micro-configurations

    NASA Astrophysics Data System (ADS)

    Elbaz, Shai; Jacob, Hila; Gat, Amir

    2016-11-01

    Gaseous flows in elastic micro-configurations is relevant to biological systems (e.g. alveolar ducts in the lungs) as well as to applications such as gas actuated soft micro-robots. We here examine the effect of low-Mach-number compressibility on creeping gaseous axial flows through linearly elastic tube and annulus micro-configurations. For steady flows, the leading-order effects of elasticity on the pressure distribution and mass-flux are obtained. For transient flow in a tube with small deformations, elastic effects are shown to be negligible in leading order due to compressibility. We then examine transient flows in annular configurations where the deformation is significant compared with the gap between the inner and outer cylinders defining the annulus. Both compressibility and elasticity are obtained as dominant terms interacting with viscosity. For a sudden flux impulse, the governing non-linear leading order diffusion equation is initially approximated by a porous-medium-equation of order 2.5 for the pressure square. However, as the fluid expand and the pressure decreases, the governing equation degenerates to a porous-medium-equation of order 2 for the pressure.

  5. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    PubMed

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  6. Determination of the neutral oxygen atom density in a plasma reactor loaded with metal samples

    NASA Astrophysics Data System (ADS)

    Mozetic, Miran; Cvelbar, Uros

    2009-08-01

    The density of neutral oxygen atoms was determined during processing of metal samples in a plasma reactor. The reactor was a Pyrex tube with an inner diameter of 11 cm and a length of 30 cm. Plasma was created by an inductively coupled radiofrequency generator operating at a frequency of 27.12 MHz and output power up to 500 W. The O density was measured at the edge of the glass tube with a copper fiber optics catalytic probe. The O atom density in the empty tube depended on pressure and was between 4 and 7 × 1021 m-3. The maximum O density was at a pressure of about 150 Pa, while the dissociation fraction of O2 molecules was maximal at the lowest pressure and decreased with increasing pressure. At about 300 Pa it dropped below 10%. The measurements were repeated in the chamber loaded with different metallic samples. In these cases, the density of oxygen atoms was lower than that in the empty chamber. The results were explained by a drain of O atoms caused by heterogeneous recombination on the samples.

  7. Temperature and pressure measurements at cold exit of counter-flow vortex tube with flow visualization of reversed flow

    NASA Astrophysics Data System (ADS)

    Yusof, Mohd Hazwan bin; Katanoda, Hiroshi; Morita, Hiromitsu

    2015-02-01

    In order to clarify the structure of the cold flow discharged from the counter-flow vortex tube (VT), the temperature and pressure of the cold flow were measured, and the existence and behavior of the reversed flow at the cold exit was studied using a simple flow visualization technique consisting of a 0.75mm-diameter needle, and an oil paint droplet. It is observed through this experiment that the Pitot pressure at the cold exit center can either be lower or higher than atmospheric pressure, depending on the inlet pressure and the cold fraction, and that a reversed flow is observed when the Pitot pressure at the cold exit center is lower than atmospheric pressure. In addition, it is observed that when reducing the cold fraction from unity at any arbitrary inlet pressure, the region of reversed and colder flow in the central part of cold exit extends in the downstream direction.

  8. Determination of heat losses and their influence on the performance characteristics of high-enthalpy hot-shot tubes

    NASA Astrophysics Data System (ADS)

    Ganimedov, V. L.; Shumsky, V. V.; Yaroslavtsev, M. I.

    2009-06-01

    An analysis of the losses of heat into the walls of settling chamber in a hypersonic hot-shot tube has been performed. Tests without diaphragm rupture showed that the fall of settling-chamber pressure during the operating flow regime in the tube was the consequence of the transfer of heat from working body to wall; this has allowed us to evaluate the heat-transfer coefficient α and the inner-surface temperature of the wall T w. An empirical formula relating the coefficient α with the pressure and working-body temperature in the settling chamber in the range of pressures and temperatures 160 to 540 bar and 700 to 3400 K was obtained. Using the gained dependences of α and T w on pressure and temperature, we have developed a physical model for calculating the working-body characteristics in the tube with allowance for enthalpy losses. We found that by the hundredth millisecond of the operating regime the disregard, in such calculations, of the wall heat flux in the first settling chamber resulted in overestimation of the stagnation temperature in the test section in comparison with similar calculations made without allowance for the heat losses by 6-18 % in terms of the full-scale temperature for aircraft flight in Mach number range 5 to 8. The developed calculation procedure has been tested in experiments without diaphragm rupture.

  9. Deposit formation and heat transfer in hydrocarbon rocket fuels

    NASA Technical Reports Server (NTRS)

    Giovanetti, A. J.; Spadaccini, L. J.; Szetela, E. J.

    1983-01-01

    An experimental research program was undertaken to investigate the thermal stability and heat transfer characteristics of several hydrocarbon fuels under conditions that simulate high-pressure, rocket engine cooling systems. The rates of carbon deposition in heated copper and nickel-plated copper tubes were determined for RP-1, propane, and natural gas using a continuous flow test apparatus which permitted independent variation and evaluation of the effect on deposit formation of wall temperature, fuel pressure, and fuel velocity. In addition, the effects of fuel additives and contaminants, cryogenic fuel temperatures, and extended duration testing with intermittent operation were examined. Parametric tests to map the thermal stability characteristics of RP-1, commercial-grade propane, and natural gas were conducted at pressures of 6.9 to 13.8 MPa, bulk fuel velocities of 30 to 90 m/s, and tube wall temperatures in the range of 230 to 810 K. Also, tests were run in which propane and natural gas fuels were chilled to 230 and 160 K, respectively. Corrosion of the copper tube surface was detected for all fuels tested. Plating the inside of the copper tubes with nickel reduced deposit formation and eliminated tube corrosion in most cases. The lowest rates of carbon deposition were obtained for natural gas, and the highest rates were obtained for propane. For all fuels tested, the forced-convection heat transfer film coefficients were satisfactorily correlated using a Nusselt-Reynolds-Prandtl number equation.

  10. Numerical investigation on nonlinear effect and vortex formation of oscillatory flow throughout a short tube in a thermoacoustic Stirling engine

    NASA Astrophysics Data System (ADS)

    Yang, Peng; Chen, Hui; Liu, Yingwen

    2017-06-01

    In this paper, a two-dimensional axisymmetric model of a thermoacoustic Stirling engine with a short tube where the cross section narrows has been developed. The transient streamlines and vortex formation through short tubes with different diameters in oscillatory flow have been investigated visually by computational fluid dynamics. Three dimensionless parameters, Reynolds number (Re), Keulegan-Carpenter number (KC), and Womersley number (Wo), are used to describe the flow regime and vortex characteristic throughout the short tube. High Re and Wo numbers indicate that the oscillatory flow develops into the turbulent flow through the short tube. The KC number has a direct effect on the transition of streamlines and the development of the vortex. For a small cross section where KC ≈ 1, streamlines rotate and the vortex forms at both sides of the short tube. The vortex stays in the main flow region, and intensity varies as streamlines are convected downstream. The velocity along the radius presents a Poiseuille profile within the influence of the vortex. For a large cross section where KC < 1, streamlines pass the short tube with little rotation and the vortex disappears in the main flow region and confines near the short tube. The velocity profile tends to be flat. The nonlinear effects including instantaneous pressure drop and power dissipation throughout the short tube are also discussed. It shows that the time averaged pressure drop is generated at the cost of power dissipation. Finally, the "effectiveness" is applied to evaluate the performance of the short tube. The results suggest that increasing the diameter of the short tube is in favor of reducing power dissipation, which is beneficial to improve "effectiveness."

  11. A comparison of measured and predicted test flow in an expansion tube with air and oxygen test gases

    NASA Technical Reports Server (NTRS)

    Aaggard, K. V.; Goad, W. K.

    1975-01-01

    Simultaneous time-resolved measurements of temperature, density, pitot pressure, and wall pressure in both air and O2 test gases were obtained in the Langley pilot model expansion tube. These tests show nonequilibrium chemical and vibrational relaxation significantly affect the test-flow condition. The use of an electromagnetic device to preopen the secondary diaphragm before the arrival of the primary shock wave resulted in an improvement in the agreement between the measured pitot pressure and the value inferred from measured density and interface velocity. Boundary-layer splitter plates used to reduce the wall boundary layer show that this disagreement in the measured and inferred pitot pressures is not a result of boundary-layer effects.

  12. Investigation of the reaction of liquid hydrogen with liquid air in a pressure tube

    NASA Technical Reports Server (NTRS)

    Karb, Erich H.

    1987-01-01

    A pressure tube should protect the FR-2 reactor from the consequences of a hydrogen-air reaction, which is conceivable in the breakdown of several safety devices of the planned cold neutron source Project FR-2/16. The magnitudes and time pattern of the pressures to be expected were investigated. In the geometry used and the ignition mechanism selected, which is comparable to the strongest ignition process conceivable in the reactor, the reaction proceeds with greater probability than combustion. The combustion is possibly smaller if local limited partial detonations are superimposed. The magnitude of the pressure was determined by the masses of the reaction partners, liquid H2 and liquid air, and determines their ratio to each other.

  13. A novel transanal tube designed to prevent anastomotic leakage after rectal cancer surgery: the WING DRAIN.

    PubMed

    Nishigori, Hideaki; Ito, Masaaki; Nishizawa, Yuji

    2017-04-01

    We introduce a novel transanal tube (TAT), named the "WING DRAIN", designed to prevent anastomotic leakage after rectal cancer surgery, and report the fundamental experiments that led to its development. We performed the basic experiments to evaluate the effect of TATs on intestinal decompression, the changes they make in patterns of watery fluid drainage, the changes in their decompression effect when the extension tube connecting the TAT to the collection bag fills with watery drainage fluid, and the variations in intestinal contact and crushing pressure made by some types of TAT. Any type of TAT contributed to decompression in the intestinal tract. Watery drainage commenced from when the water level first rose to the hole in the tip of drain. The intestinal pressure increased with the length of the vertical twist in an extension tube. The crushing pressures of most types of TAT were high enough to cause injury to the intestine. We resolved the problems using an existing TAT for the purpose of intestinal decompression and by creating the first specialized TAT designed to prevent anastomotic leakage after rectal cancer surgery in Japan.

  14. Starter for inductively coupled plasma tube

    DOEpatents

    Hull, Donald E.; Bieniewski, Thomas M.

    1988-01-01

    A starter assembly is provided for use with an inductively coupled plasma (ICP) tube to reliably initate a plasma at internal pressures above about 30 microns. A conductive probe is inserted within the inductor coil about the tube and insulated from the tube shield assembly. A capacitive circuit is arranged for momentarily connecting a high voltage radio-frequency generator to the probe while simultaneously energizing the coil. When the plasma is initiated the probe is disconnected from the generator and electrically connected to the shield assembly for operation.

  15. Drift chambers on the basis of Mylar tube blocks

    NASA Astrophysics Data System (ADS)

    Budagov, Yu.; Chirikov-Zorin, I.; Golovanov, L.; Khazins, D.; Kuritsin, A.; Pukhov, O.; Zhukov, V.

    1993-06-01

    Prototypes of drift chambers constructed of Mylar tube blocks were tested. The purpose of developing tube blocks technology was to create long chambers (up to 3-4 m). Counting and drift characteristics of the chambers for different values of the gas pressure and different diameters of sense wires are presented. The lifetime of the chambers is determined. A photoeffect in the visible spectrum on the surface of the thin film aluminium cathode, which covers the Mylar tubes was observed.

  16. Laser interferometer/Preston tube skin-friction comparison in shock/boundary-layer interaction

    NASA Technical Reports Server (NTRS)

    Kim, K.-S.; Lee, Y.; Settles, G. S.

    1991-01-01

    An evaluation is conducted of the accuracy of the 'Preston tube' surface pitot-pressure skin friction measurement method relative to the already proven laser interferometer skin-friction meter in a swept shock wave/turbulent boundary-layer interaction. The Preston tube was used to estimate the total shear-stress distribution in a fin-generated swept shock-wave/turbulent boundary-layer interaction. The Keener-Hopkins calibration method using the isentropic relation to calculate the Preston-tube Mach number produces the best results.

  17. Apparatuses for prestressing rod-type specimens in torsion for in-situ passive fracture toughness testing in an extremely high-pressure environment of hydrogen

    DOEpatents

    Wang, Jy-an [Oak Ridge, TN; Liu, Ken C [Oak Ridge, TN; Feng, Zhili [Knoxville, TN

    2012-05-15

    An in-situ specimen fixture particularly adapted for prestressing rod-type SNTT-type specimens comprising a tube and end cap wherein the specimen is secured at one end to the tube, and at the opposite end to the end cap. The end cap is rotatable relative to the tube, and may be fixedly secured for creating a torsional force prestressing the specimen enclosed within the tube.

  18. Bifurcation parameters of a reflected shock wave in cylindrical channels of different roughnesses

    NASA Astrophysics Data System (ADS)

    Penyazkov, O.; Skilandz, A.

    2018-03-01

    To investigate the effect of bifurcation on the induction time in cylindrical shock tubes used for chemical kinetic experiments, one should know the parameters of the bifurcation structure of a reflected shock wave. The dynamics and parameters of the shock wave bifurcation, which are caused by reflected shock wave-boundary layer interactions, are studied experimentally in argon, in air, and in a hydrogen-nitrogen mixture for Mach numbers M = 1.3-3.5 in a 76-mm-diameter shock tube without any ramp. Measurements were taken at a constant gas density behind the reflected shock wave. Over a wide range of experimental conditions, we studied the axial projection of the oblique shock wave and the pressure distribution in the vicinity of the triple Mach configuration at 50, 150, and 250 mm from the endwall, using side-wall schlieren and pressure measurements. Experiments on a polished shock tube and a shock tube with a surface roughness of 20 {μ }m Ra were carried out. The surface roughness was used for initiating small-scale turbulence in the boundary layer behind the incident shock wave. The effect of small-scale turbulence on the homogenization of the transition zone from the laminar to turbulent boundary layer along the shock tube perimeter was assessed, assuming its influence on a subsequent stabilization of the bifurcation structure size versus incident shock wave Mach number, as well as local flow parameters behind the reflected shock wave. The influence of surface roughness on the bifurcation development and pressure fluctuations near the wall, as well as on the Mach number, at which the bifurcation first develops, was analyzed. It was found that even small additional surface roughness can lead to an overshoot in pressure growth by a factor of two, but it can stabilize the bifurcation structure along the shock tube perimeter.

  19. Collapsible pistons for light-gas guns

    NASA Technical Reports Server (NTRS)

    Teng, R. N.

    1973-01-01

    Moving and expandable parts of gun consist of pump-tube diaphragm, piston, launch-tube diaphragm, and saboted projectile. As a result of improved piston design, pressure cycle has been significantly improved by smoother buildup, increasing muzzle velocities up to 50%.

  20. Visiting your baby in the NICU

    MedlinePlus

    ... the baby. This can seem scary to new parents. They are not hurting the baby. Some tubes and wires are connected to monitors. They check the baby's breathing, heart rate, blood pressure, and temperature at all times. A tube through ...

  1. Water Barometer.

    ERIC Educational Resources Information Center

    Akridge, Russell

    1993-01-01

    This activity makes a barometer out of 50 feet of clear vinyl tubing and a gallon of tea. The barometer is used in a building stairwell where students have easy access to the tube. Discusses possible pitfalls, vapor pressure, elevation, and weather influences. (MVL)

  2. An experimental investigation of wall boundary layer transition Reynolds numbers in an expansion tube

    NASA Technical Reports Server (NTRS)

    Weilmuenster, K. J.

    1974-01-01

    Experimental measurements of boundary-layer transition in an expansion-tube test-gas flow are presented along with radial distributions of pitot pressure. An integral method for calculating constant Reynolds number lines for an expansion-tube flow is introduced. Comparison of experimental data and constant Reynolds number calculations has shown that for given conditions, wall boundary-layer transition occurs at a constant Reynolds number in an expansion-tube flow. Operating conditions in the expansion tube were chosen so that the effects of test-gas nonequilibrium on boundary-layer transition could be studied.

  3. 40 CFR 147.3107 - Mechanical integrity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...

  4. 40 CFR 147.3107 - Mechanical integrity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...

  5. 40 CFR 147.3107 - Mechanical integrity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...

  6. 40 CFR 147.3107 - Mechanical integrity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...

  7. Two-phase heat transfer and pressure drop of LNG during saturated flow boiling in a horizontal tube

    NASA Astrophysics Data System (ADS)

    Chen, Dongsheng; Shi, Yumei

    2013-12-01

    Two-phase heat transfer and pressure drop of LNG (liquefied natural gas) have been measured in a horizontal smooth tube with an inner diameter of 8 mm. The experiments were conducted at inlet pressures from 0.3 to 0.7 MPa with a heat flux of 8-36 kW m-2, and mass flux of 49.2-201.8 kg m-2 s-1. The effect of vapor quality, inlet pressure, heat flux and mass flux on the heat transfer characteristic are discussed. The comparisons of the experimental data with the predicted value by existing correlations are analyzed. Zou et al. (2010) correlation shows the best accuracy with 24.1% RMS deviation among them. Moreover four frictional pressure drop methods are also chosen to compare with the experimental database.

  8. High-sensitivity pressure sensor based on fiber Mach-Zehnder interferometer

    NASA Astrophysics Data System (ADS)

    Wu, Yue; Xu, Yao; Yang, Yuguang; Jin, Wenxing; Jiang, Youchao; Shen, Ya; Jian, Shuisheng

    2017-10-01

    In this paper we propose and experimentally demonstrate an optical fiber structure sensor based on a Mach-Zehnder interferometer for pressure measurement. The fiber sensor is composed of a single-mode-no-core-single-mode structure, a section of capillary pure silica tube and refractive index matching fluid (RIMF). As the pressure decreases, the sealed air in the tube expands and the liquid level of the RIMF increases, which causes a wavelength shift of the interferometer. The measurement of the pressure variation can thus be achieved by monitoring the wavelength shift. The experimental results agree well with the numerical simulation, and a maximum pressure sensitivity of 266.6 nm Mpa-1 is achieved experimentally. Furthermore, the proposed fiber sensor has the potential to obtain higher sensitivity by enlarging the length of the air cavity.

  9. Compliant electrospun silk fibroin tubes for small vessel bypass grafting.

    PubMed

    Marelli, Benedetto; Alessandrino, Antonio; Farè, Silvia; Freddi, Giuliano; Mantovani, Diego; Tanzi, Maria Cristina

    2010-10-01

    Processing silk fibroin (SF) by electrospinning offers a very attractive opportunity for producing three-dimensional nanofibrillar matrices in tubular form, which may be useful for a biomimetic approach to small calibre vessel regeneration. Bypass grafting of small calibre vessels, with a diameter less than 6mm, is performed mainly using autografts, like the saphenous vein or internal mammary artery. At present no polymeric grafts made of SF are commercially available, mainly due to inadequate properties (low compliance and lack of endothelium cells). The aim of this work was to electrospin SF into tubular structures (Ø=6mm) for small calibre vessel grafting, characterize the morphological, chemico-physical and mechanical properties of the electrospun SF structures and to validate their potential to interact with cells. The morphological properties of electrospun SF nanofibres were investigated by scanning electron microscopy. Chemico-physical analyses revealed an increase in the crystallinity of the structure of SF nanofibres on methanol treatment. Mechanical tests, i.e. compliance and burst pressure measurements, of the electrospun SF tubes showed that the inner pressure to radial deformation ratio was linear for elongation up to 15% and pressure up to 400 mm Hg. The mean compliance value between 80 and 120 mm Hg was higher than the values reported for both Goretex(R) and Dacron(R) grafts and for bovine heterografts, but still slightly lower than those of saphenous and umbilical vein, which nowadays represent the gold standard for the replacement of small calibre arteries. The electrospun tubes resisted up to 575+/-17 mmHg, which is more than four times the upper physiological pressure of 120 mmHg and more than twice the pathological upper pressures (range 180-220 mmHg). The in vitro tests showed a good cytocompatibility of the electrospun SF tubes. Therefore, the electrospun SF tubes developed within this work represent a suitable candidate for small calibre blood vessel replacement. 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Supercritical convection, critical heat flux, and coking characteristics of propane

    NASA Technical Reports Server (NTRS)

    Rousar, D. C.; Gross, R. S.; Boyd, W. C.

    1984-01-01

    The heat transfer characteristics of propane at subcritical and supercritical pressure were experimentally evaluated using electrically heated Monel K-500 tubes. A design correlation for supercritical heat transfer coefficient was established using the approach previously applied to supercritical oxygen. Flow oscillations were observed and the onset of these oscillations at supercritical pressures was correlated with wall-to-bulk temperature ratio and velocity. The critical heat flux measured at subcritical pressure was correlated with the product of velocity and subcooling. Long duration tests at fixed heat flux conditions were conducted to evaluate coking on the coolant side tube wall and coking rates comparable to RP-1 were observed.

  11. Performance data of the new free-piston shock tunnel T5 at GALCIT

    NASA Technical Reports Server (NTRS)

    Hornung, H.; Sturtevant, B.; Belanger, J.; Sanderson, S.; Brouillette, M.; Jenkins, M.

    1992-01-01

    A new free piston shock tunnel has been constructed at the Graduate Aeronautical Laboratories at Caltec. Compression tube length is 30 m and diameter 300 mm. Shock tube length is 12 m and diameter 90 mm. Piston mass is 150 kg and maximum diaphragm burst pressure is 130 MPa. Special features of this facility are that the pressure in the driver gas is monitored throughout the compression process until well after diaphragm rupture, and that the diaphragm burst pressure can be measured dynamically. An analysis of initial performance data including transient behavior of the flow over models is presented.

  12. Simulation analysis and experimental verification of spiral-tube-type valveless piezoelectric pump with gyroscopic effect

    NASA Astrophysics Data System (ADS)

    Leng, Xuefei; Zhang, Jianhui; Jiang, Yan; Wang, Shouyin; Zhao, Chunsheng

    2014-07-01

    The current research of the valveless piezoelectric pump focuses on increasing the flow rate and pressure differential. Compared with the valve piezoelectric pump, the valveless one has excellent performances in simple structure, low cost, and easy miniaturization. So, their important development trend is the mitigation of their weakness, and the multi-function integration. The flow in a spiral tube element is sensitive to the element attitude caused by the Coriolis force, and that a valveless piezoelectric pump is designed by applying this phenomenon. The pump has gyroscopic effect, and has both the actuator function of fluid transfer and the sensor function, which can obtain the angular velocity when its attitude changes. First, the present paper analyzes the flow characteristics in the tube, obtains the calculation formula for the pump flow, and identifies the relationship between pump attitude and flow, which clarifies the impact of flow and driving voltage, frequency, spiral line type and element attitude, and verifies the gyroscopic effect of the pump. Then, the finite element simulation is used to verify the theory. Finally, a pump is fabricated for experimental testing of the relationship between pump attitude and pressure differential. Experimental results show that when Archimedes spiral θ=4π is selected for the tube design, and the rotation speed of the plate is 70 r/min, the pressure differential is 88.2 Pa, which is 1.5 times that of 0 r/min rotation speed. The spiral-tube-type valveless piezoelectric pump proposed can turn the element attitude into a form of pressure output, which is important for the multi-function integration of the valveless piezoelectric pump and for the development of civil gyroscope in the future.

  13. Quality of life improvement after pressure equalization tube placement in Down syndrome: A prospective study.

    PubMed

    Labby, Alex; Mace, Jess C; Buncke, Michelle; MacArthur, Carol J

    2016-09-01

    To evaluate quality-of-life changes after bilateral pressure equalization tube placement with or without adenoidectomy for the treatment of chronic otitis media with effusion or recurrent acute otitis media in a pediatric Down syndrome population compared to controls. Prospective case-control observational study. The OM Outcome Survey (OMO-22) was administered to both patients with Down syndrome and controls before bilateral tube placement with or without adenoidectomy and at an average of 6-7 months postoperatively. Thirty-one patients with Down syndrome and 34 controls were recruited. Both pre-operative and post-operative between-group and within-group score comparisons were conducted for the Physical, Hearing/Balance, Speech, Emotional, and Social domains of the OMO-22. Both groups experienced improvement of mean symptom scores post-operatively. Patients with Down syndrome reported significant post-operative improvement in mean Physical and Hearing domain item scores while control patients reported significant improvement in Physical, Hearing, and Emotional domain item scores. All four symptom scores in the Speech domain, both pre-operatively and post-operatively, were significantly worse for Down syndrome patients compared to controls (p ≤ 0.008). Surgical placement of pressure equalizing tubes results in significant quality of life improvements in patients with Down syndrome and controls. Problems related to speech and balance are reported at a higher rate and persist despite intervention in the Down syndrome population. It is possible that longer follow up periods and/or more sensitive tools are required to measure speech improvements in the Down syndrome population after pressure equalizing tube placement ± adenoidectomy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature.

    PubMed

    Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv

    2016-01-01

    Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Design and Construction of a Shock Tube Experiment for Multiphase Instability Experiments

    NASA Astrophysics Data System (ADS)

    Middlebrooks, John; Black, Wolfgang; Avgoustopoulos, Constantine; Allen, Roy; Kathakapa, Raj; Guo, Qiwen; McFarland, Jacob

    2016-11-01

    Hydrodynamic instabilities are important phenomena that have a wide range of practical applications in engineering and physics. One such instability, the shock driven multiphase instability (SDMI), arises when a shockwave accelerates an interface between two particle-gas mixtures with differing multiphase properties. The SDMI is present in high energy explosives, scramjets, and supernovae. A practical way of studying shock wave driven instabilities is through experimentation in a shock tube laboratory. This poster presentation will cover the design and data acquisition process of the University of Missouri's Fluid Mixing Shock Tube Laboratory. In the shock tube, a pressure generated shockwave is passed through a multiphase interface, creating the SDMI instability. This can be photographed for observation using high speed cameras, lasers, and advance imaging techniques. Important experimental parameters such as internal pressure and temperature, and mass flow rates of gases can be set and recorded by remotely controlled devices. The experimental facility provides the University of Missouri's Fluid Mixing Shock Tube Laboratory with the ability to validate simulated experiments and to conduct further inquiry into the field of shock driven multiphase hydrodynamic instabilities. Advisor.

  16. Alternate tube plugging criteria for steam generator tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cueto-Felgueroso, C.; Aparicio, C.B.

    1997-02-01

    The tubing of the Steam Generators constitutes more than half of the reactor coolant pressure boundary. Specific requirements governing the maintenance of steam generator tubes integrity are set in Plant Technical Specifications and in Section XI of the ASME Boiler and Pressure Vessel Code. The operating experience of Steam Generator tubes of PWR plants has shown the existence of some types of degradatory processes. Every one of these has an specific cause and affects one or more zones of the tubes. In the case of Spanish Power Plants, and depending on the particular Plant considered, they should be mentioned themore » Primary Water Stress Corrosion Cracking (PWSCC) at the roll transition zone (RTZ), the Outside Diameter Stress Corrosion Cracking (ODSCC) at the Tube Support Plate (TSP) intersections and the fretting with the Anti-Vibration Bars (AVBs) or with the Support Plates in the preheater zone. The In-Service Inspections by Eddy Currents constitutes the standard method for assuring the SG tubes integrity and they permit the monitoring of the defects during the service life of the plant. When the degradation reaches a determined limit, called the plugging limit, the SG tube must be either repaired or retired from service by plugging. Customarily, the plugging limit is related to the depth of the defect. Such depth is typically 40% of the wall thickness of the tube and is applicable to any type of defect in the tube. In its origin, that limit was established for tubes thinned by wastage, which was the predominant degradation in the seventies. The application of this criterion for axial crack-like defects, as, for instance, those due to PWSCC in the roll transition zone, has lead to an excessive and unnecessary number of tubes being plugged. This has lead to the development of defect specific plugging criteria. Examples of the application of such criteria are discussed in the article.« less

  17. Obtaining off-Hugoniot equation of state data on solid metals at extreme pressures via pulsed-power driven cylindrical liner implosions

    NASA Astrophysics Data System (ADS)

    Lemke, Raymond

    2015-06-01

    The focus of this talk is on magnetically driven, liner implosion experiments on the Z machine (Z) in which a solid, metal tube is shocklessly compressed to multi-megabar pressure. The goal of the experiments is to collect velocimetry data that can be used in conjunction with a new optimization based analysis technique to infer the principal isentrope of the tube material over a range of pressures. For the past decade, shock impact and ramp loading experiments on Z have used planar platforms exclusively. While producing state-of-the-art results for material science, it is difficult to produce drive pressures greater than 6 Mbar in the divergent planar geometry. In contrast, a cylindrical liner implosion is convergent; magnetic drive pressures approaching 50 Mbar are possible with the available current on Z (~ 20 MA). In our cylindrical experiments, the liner comprises an inner tube composed of the sample material (e.g., Ta) of unknown equation of state, and an outer tube composed of aluminum (Al) that serves as the current carrying cathode. Internal to the sample are fielded multiple PDV (Photonic Doppler Velocimetry) probes that measure velocity of the inner free surface of the imploding sample. External to the composite liner, at much larger radius, is an Al tube that is the return current anode. VISAR (velocity interferometry system for any reflector) probes measure free surface velocity of the exploding anode. Using the latter, MHD and optimization codes are employed to solve an inverse problem that yields the current driving the liner implosion. Then, the drive current, PDV velocity, MHD and optimization codes, are used to solve another inverse problem that yields pressure vs. density on approximately the principal isentrope of the sample material. Results for Ta, Re, and Cu compressed to ~ 10 Mbar are presented. Sandia National Laboratories is a multiprogram laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the US DOE's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  18. 75 FR 71351 - Airworthiness Directives; Pratt & Whitney PW4000 Series Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-23

    ... products listed above. This AD requires a one-time visual inspection of the No. 3 bearing oil pressure tube, part number (P/N) 51J041-01, P/N 50J604-01, or P/N 50J924-01. Tubes that are found cracked or repaired must be removed from service. This AD also prohibits repaired tubes from being installed. This AD...

  19. SIGHT - A balloon borne hard X-ray telescope

    NASA Technical Reports Server (NTRS)

    Wilkerson, J.; Edberg, T. K.; Hurley, K.; Lin, R. P.; Parsons, A.

    1991-01-01

    The authors report on progress toward developing a large-area, high-pressure xenon gas scintillator for use in hard X-ray astrophysics. Proof test results for a low-mass pressure vessel are presented. The design of a high-voltage multiplier board operating inside the scintillation chamber is discussed. The development of tetrakis-dimethylamine-thylene (TMAE)-based proportional tubes for detecting primary scintillation in the xenon is described. Finally, Monte Carlo tests of a scheme to use conventional photomultiplier tubes are discussed.

  20. Coolant monitoring apparatus for nuclear reactors

    DOEpatents

    Tokarz, Richard D.

    1983-01-01

    A system for monitoring coolant conditions within a pressurized vessel. A length of tubing extends outward from the vessel from an open end containing a first line restriction at the location to be monitored. The flowing fluid is cooled and condensed before passing through a second line restriction. Measurement of pressure drop at the second line restriction gives an indication of fluid condition at the first line restriction. Multiple lengths of tubing with open ends at incremental elevations can measure coolant level within the vessel.

  1. Characterization and Performance of a Liquid Hydrocarbon-Fueled Pulse Detonation Rocket Engine

    DTIC Science & Technology

    2001-12-01

    head wall pressure (P3) and the two sensors at the end of the tube provided indication of detonation wave passage (Wave1 and Wave2 ). These data...wave speed using the time of passage at Wave1 and Wave2 and the user-defined value of the distance between each sensor (this distance varied slightly...for each tube extension). A detonation velocity of zero was returned for any event in which neither Wave1 or Wave2 sensed a pressure rise of

  2. Potential Danger of Pre-Pump Clamping on Negative Pressure-Associated Gaseous Microemboli Generation During Extracorporeal Life Support--An In Vitro Study.

    PubMed

    Wang, Shigang; Chin, Brian J; Gentile, Frank; Kunselman, Allen R; Palanzo, David; Ündar, Akif

    2016-01-01

    The objectives of this study were to investigate the relationship between revolution speed of a conventional centrifugal pump and negative pressure at the inlet of the pump by clamping the tubing upstream of the pump, and to verify whether negative pressure leads to gaseous microemboli (GME) production in a simulated adult extracorporeal life support (ECLS) system. The experimental circuit, including a Maquet Rotaflow centrifugal pump and a Medos Hilite 7000 LT polymethyl-pentene membrane oxygenator, was primed with packed red blood cells (hematocrit 35%). Negative pressure was created in the circuit by clamping the tubing upstream of the pump for 10 s, and then releasing the clamp. An emboli detection and classification quantifier was used to record GME volume and count at pre-oxygenator and post-oxygenator sites, and pressure and flow rate data were collected using a custom-based data acquisition system. All trials were conducted at 36°C at revolution speeds of 2000-4000 rpm (500 rpm increment). The flow rates were 1092.5-4708.4 mL/min at the revolution speeds of 2000-4000 rpm. Higher revolution speed generated higher negative pressure at the pre-pump site when clamping the tubing upstream of the pump (-108.3 ± 0.1 to -462.0 ± 0.5 mm Hg at 2000-4000 rpm). Moreover, higher negative pressure was associated with a larger number and volume of GME at pre-oxygenator site after de-clamp (GME count 10,573 ± 271 at pre-oxygenator site at 4000 rpm). The results showed that there was a potential danger of delivering GME to the patient when clamping pre-pump tubing during ECLS using a centrifugal pump. Our results warrant further clinical studies to investigate this phenomenon. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Liquid oscillations in a U-tube

    NASA Astrophysics Data System (ADS)

    Munguía Aguilar, Horacio; Maldonado, Rigoberto Franco; Barba Navarro, Luis

    2018-01-01

    In hydrostatics, pressure measurement with U-gauges and their relationship to density is a well-known experiment. Very little is studied or experimented with the dynamics of the movement of a liquid in a U-tube probably due to its theoretical complexity but, after all, it is a simple damped oscillating system. In this paper we present a relatively simple experiment that allows studying in some detail the dynamics of the movement of a liquid in a U-tube when an initial pressure gradient is applied. In order to record the information of the column displacement as a function of time we have developed a position sensor system based on a solar cell that allows the recording of the experiment using a simple data acquisition system.

  4. Concentric wrench for blind access opening in a turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurer, Kurt Neal; Drlik, Gary Joseph; Gibler, Edward Eugene

    The concentric wrench includes an outer tube having flats at one end and a gripping surface at an opposite end. An inner tube has interior flats at one end and a gripping surface at its opposite end. With the inner and outer tubes disposed about a pressure transmitting conduit, the tubes may be inserted into a blind access opening in the outer turbine casing to engage the flats of the tubes against hex nuts of an internal fitting. By relatively rotating the tubes using the externally exposed gripping surfaces, the threaded connection between the parts of the fitting bearing themore » respective hex nuts can be tightened or loosened.« less

  5. Modular heat exchanger

    DOEpatents

    Culver, Donald W.

    1978-01-01

    A heat exchanger for use in nuclear reactors includes a heat exchange tube bundle formed from similar modules each having a hexagonal shroud containing a large number of thermally conductive tubes which are connected with inlet and outlet headers at opposite ends of each module, the respective headers being adapted for interconnection with suitable inlet and outlet manifold means. In order to adapt the heat exchanger for operation in a high temperature and high pressure environment and to provide access to all tube ports at opposite ends of the tube bundle, a spherical tube sheet is arranged in sealed relation across the chamber with an elongated duct extending outwardly therefrom to provide manifold means for interconnection with the opposite end of the tube bundle.

  6. Review of vortex tube expansion in vapour compression refrigeration system

    NASA Astrophysics Data System (ADS)

    Liu, Yefeng; Yu, Jun

    2018-05-01

    A vortex tube expansion device replacing the throttle valve is proposed to improve the efficiency of vapour compression refrigeration cycle by reducing the loss of irreversibility in expansion process. The vortex tube is well-suited for these applications because it is simple, compact, light, quiet. Thus, this paper presents an overview of the thermodynamic analysis of vapour compression refrigeration cycle with vortex tube expansion device using different refrigerants. The paper also reviews the experiments and the calculations presented in previous studies on temperature separation in the vortex tube. The temperature separation mechanism and the flow-field inside the vortex tubes is explored by measuring the pressure, velocity, and temperature fields.

  7. Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.

    1990-01-01

    Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

  8. Acceleration of tendon-bone healing of anterior cruciate ligament graft using intermittent negative pressure in rabbits.

    PubMed

    Sun, Zhengming; Wang, Xiaoqing; Ling, Ming; Wang, Wei; Chang, Yanhai; Yang, Guang; Dong, Xianghui; Wu, Shixun; Wu, Xueyuan; Yang, Bo; Chen, Ming

    2017-04-18

    The purpose of this study was to test effects of negative pressure on tendon-bone healing after reconstruction of anterior cruciate ligament (ACL) in rabbits. Hind legs of 24 New Zealand White rabbits were randomly selected as negative pressure group and the contralateral hind legs as control. Reconstruction of the ACL was done. Joints of the negative pressure side were placed with drainage tubes connecting the micro-negative pressure aspirator. Control side was placed with ordinary drainage tubes. Drainage tubes on both sides were removed at the same time 5 days after operation. After 6 weeks, joint fluid was drawn to detect the expression levels of interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α); at the same time, femur-ligament-tibia complex was obtained to determine tendon graft tension and to observe the histomorphology, blood vessels of the tendon-bone interface, and expression of vascular endothelial growth factor (VEGF). The maximum load breakage of tendon graft was significantly greater in the negative pressure group than in the control group (P < 0.05). Histological studies of the tendon-bone interface found that there was more new bone formation containing chondroid cells and aligned connective tissue in the negative pressure group than in the control group. Expression of VEGF was higher in the negative pressure group than in the control group (P < 0.01). Content of IL-1β and TNF-α in synovial fluid is lower in the negative pressure group than in the control group (P < 0.01). Intermittent negative pressure plays an active role in tendon-bone healing and creeping substitution of ACL reconstruction in the rabbits.

  9. Vocal tract and glottal function during and after vocal exercising with resonance tube and straw.

    PubMed

    Guzman, Marco; Laukkanen, Anne-Maria; Krupa, Petr; Horáček, Jaromir; Švec, Jan G; Geneid, Ahmed

    2013-07-01

    The present study aimed to investigate the vocal tract and glottal function during and after phonation into a tube and a stirring straw. A male classically trained singer was assessed. Computerized tomography (CT) was performed when the subject produced [a:] at comfortable speaking pitch, phonated into the resonance tube and when repeating [a:] after the exercise. Similar procedure was performed with a narrow straw after 15 minutes silence. Anatomic distances and area measures were obtained from CT midsagittal and transversal images. Acoustic, perceptual, electroglottographic (EGG), and subglottic pressure measures were also obtained. During and after phonation into the tube or straw, the velum closed the nasal passage better, the larynx position lowered, and hypopharynx area widened. Moreover, the ratio between the inlet of the lower pharynx and the outlet of the epilaryngeal tube became larger during and after tube/straw phonation. Acoustic results revealed a stronger spectral prominence in the singer/speaker's formant cluster region after exercising. Listening test demonstrated better voice quality after straw/tube than before. Contact quotient derived from EGG decreased during both tube and straw and remained lower after exercising. Subglottic pressure increased during straw and remained somewhat higher after it. CT and acoustic results indicated that vocal exercises with increased vocal tract impedance lead to increased vocal efficiency and economy. One of the major changes was the more prominent singer's/speaker's formant cluster. Vocal tract and glottal modifications were more prominent during and after straw exercising compared with tube phonation. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  10. Accurate measurement of dispersion data through short and narrow tubes used in very high-pressure liquid chromatography.

    PubMed

    Gritti, Fabrice; McDonald, Thomas; Gilar, Martin

    2015-09-04

    An original method is proposed for the accurate and reproducible measurement of the time-based dispersion properties of short L< 50cm and narrow rc< 50μm tubes at mobile phase flow rates typically used in very high-pressure liquid chromatography (vHPLC). Such tubes are used to minimize sample dispersion in vHPLC; however, their dispersion characteristics cannot be accurately measured at such flow rates due to system dispersion contribution of vHPLC injector and detector. It is shown that using longer and wider tubes (>10μL) enables a reliable measurement of the dispersion data. We confirmed that the dimensionless plot of the reduced dispersion coefficient versus the reduced linear velocity (Peclet number) depends on the aspect ratio, L/rc, of the tube, and unexpectedly also on the diffusion coefficient of the analyte. This dimensionless plot could be easily obtained for a large volume tube, which has the same aspect ratio as that of the short and narrow tube, and for the same diffusion coefficient. The dispersion data for the small volume tube are then directly extrapolated from this plot. For instance, it is found that the maximum volume variances of 75μm×30.5cm and 100μm×30.5cm prototype finger-tightened connecting tubes are 0.10 and 0.30μL(2), respectively, with an accuracy of a few percent and a precision smaller than seven percent. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Measurements and computations of mass flow and momentum flux through short tubes in rarefied gases

    NASA Astrophysics Data System (ADS)

    Lilly, T. C.; Gimelshein, S. F.; Ketsdever, A. D.; Markelov, G. N.

    2006-09-01

    Gas flows through orifices and short tubes have been extensively studied from the 1960s through the 1980s for both fundamental and practical reasons. These flows are a basic and often important element of various modern gas driven instruments. Recent advances in micro- and nanoscale technologies have paved the way for a generation of miniaturized devices in various application areas, from clinical analyses to biochemical detection to aerospace propulsion. The latter is the main area of interest of this study, where rarefied gas flow into a vacuum through short tubes with thickness-to-diameter ratios varying from 0.015 to 1.2 is investigated both experimentally and numerically with kinetic and continuum approaches. Helium and nitrogen gases are used in the range of Reynolds numbers from 0.02 to 770 (based on the tube diameter), corresponding to Knudsen numbers from 40 down to about 0.001. Propulsion properties of relatively thin and thick tubes are examined. Good agreement between experimental and numerical results is observed for mass flow rate and momentum flux, the latter being corrected for the experimental facility background pressure. For thick-to-thin tube ratios of mass flow and momentum flux versus pressure, a minimum is observed at a Knudsen number of about 0.5. A short tube propulsion efficiency is shown to be much higher than that of a thin orifice. The effect of surface specularity on a thicker tube specific impulse was found to be relatively small.

  12. Design of distributed JT (Joule-Thomson) effect heat exchanger for superfluid 2 K cooling device

    NASA Astrophysics Data System (ADS)

    Jeong, S.; Park, C.; Kim, K.

    2018-03-01

    Superfluid at 2 K or below is readily obtained from liquid helium at 4.2 K by reducing its vapour pressure. For better cooling performance, however, the cold energy of vaporized helium at 2 K chamber can be effectively utilized in a recuperator which is specially designed in this paper for accomplishing so-called the distributed Joule-Thomson (JT) expansion effect. This paper describes the design methodology of distributed JT effect heat exchanger for 2 K JT cooling device. The newly developed heat exchanger allows continuous significant pressure drop at high-pressure part of the recuperative heat exchanger by using a capillary tube. Being different from conventional recuperative heat exchangers, the efficient JT effect HX must consider the pressure drop effect as well as the heat transfer characteristic. The heat exchanger for the distributed JT effect actively utilizes continuous pressure loss at the hot stream of the heat exchanger by using an OD of 0.64 mm and an ID of 0.4 mm capillary tube. The analysis is performed by dividing the heat exchanger into the multiple sub-units of the heat exchange part and JT valve. For more accurate estimation of the pressure drop of spirally wound capillary tube, preliminary experiments are carried out to investigate the friction factor at high Reynolds number. By using the developed pressure drop correlation and the heat transfer correlation, the specification of the heat exchanger with distributed JT effect for 2 K JT refrigerator is determined.

  13. Study of the velocity distribution influence upon the pressure pulsations in draft tube model of hydro-turbine

    NASA Astrophysics Data System (ADS)

    Sonin, V.; Ustimenko, A.; Kuibin, P.; Litvinov, I.; Shtork, S.

    2016-11-01

    One of the mechanisms of generation of powerful pressure pulsations in the circuit of the turbine is a precessing vortex core, formed behind the runner at the operation points with partial or forced loads, when the flow has significant residual swirl. To study periodic pressure pulsations behind the runner the authors of this paper use approaches of experimental modeling and methods of computational fluid dynamics. The influence of velocity distributions at the output of the hydro turbine runner on pressure pulsations was studied based on analysis of the existing and possible velocity distributions in hydraulic turbines and selection of the distribution in the extended range. Preliminary numerical calculations have showed that the velocity distribution can be modeled without reproduction of the entire geometry of the circuit, using a combination of two blade cascades of the rotor and stator. Experimental verification of numerical results was carried out in an air bench, using the method of 3D-printing for fabrication of the blade cascades and the geometry of the draft tube of hydraulic turbine. Measurements of the velocity field at the input to a draft tube cone and registration of pressure pulsations due to precessing vortex core have allowed building correlations between the velocity distribution character and the amplitude-frequency characteristics of the pulsations.

  14. Blood in the gastric lumen increases splanchnic blood flow and portal pressure in portal-hypertensive rats.

    PubMed

    Chen, L; Groszmann, R J

    1996-10-01

    In portal-hypertensive humans, portal blood flow and pressure increase after a meal. These hemodynamic changes may increase variceal rupture risk. The aim of this study was to determine whether blood in the stomach lumen increases splanchnic flow and portal pressure (PP) in portal-hypertensive rats. superior mesenteric artery flow and PP were measured in conscious, unrestrained, fasted partial portal vein-ligated rats with chronically implanted Doppler flow probes or portal vein catheters before and after gavage with heparinized, warmed blood from donor rats, air, standard meal, or empty tube. Percentage of changes in flow and pressure from baseline were significantly greater after gavage with blood (an increase of 22.6% +/- 3.5% and an increase of 16.4% +/- 3.1%, respectively) than empty tube (an increase of 3.4% +/- 0.6% and a decrease of 5.4% +/- 3.5%, respectively) (P < 0.005). Percentage of changes in flow and pressure were slightly but insignificantly greater after gavage with air vs. empty tube (P < 0.005). In portal-hypertensive rats, blood in the stomach lumen significantly increases splanchnic blood flow and PP. Splanchnic hyperemia from absorption of blood's calories probably contributes to these hemodynamic changes. In patients with variceal hemorrhage, blood in the stomach may increase the risk of persistent variceal bleeding or rebleeding.

  15. Evaluation of candidate Stirling engine heater tube alloys after 3500 hours exposure to high pressure doped hydrogen or helium

    NASA Technical Reports Server (NTRS)

    Misencik, J. A.; Titran, R. H.

    1984-01-01

    The heater head tubes of current prototype automotive Stirling engines are fabricated from alloy N-155, an alloy which contains 20 percent cobalt. Because the United States imports over 90 percent of the cobalt used in this country and resource supplies could not meet the demand imposed by automotive applications of cobalt in the heater head (tubes plus cylinders and regenerator housings), it is imperative that substitute alloys free of cobalt be identified. The research described herein focused on the heater head tubes. Sixteen alloys (15 potential substitutes plus the 20 percent Co N-155 alloy) were evaluated in the form of thin wall tubing in the NASA Lewis Research Center Stirling simulator materials diesel fuel fired test rigs. Tubes filled with either hydrogen doped with 1 percent CO2 or with helium at a gas pressure of 15 MPa and a temperature of 820 C were cyclic endurance tested for times up to 3500 hr. Results showed that two iron-nickel base superalloys, CG-27 and Pyromet 901 survived the 3500 hr endurance test. The remaining alloys failed by creep-rupture at times less than 3000 hr, however, several other alloys had superior lives to N-155. Results further showed that doping the hydrogen working fluid with 1 vol % CO2 is an effective means of reducing hydrogen permeability through all the alloy tubes investigated.

  16. Tracheal Tube Design and Ventilator-Associated Pneumonia.

    PubMed

    Rouzé, Anahita; Jaillette, Emmanuelle; Poissy, Julien; Préau, Sébastien; Nseir, Saad

    2017-10-01

    Microaspiration of contaminated oropharyngeal and gastric secretions is the main mechanism for ventilator-associated pneumonia (VAP) in critically ill patients. Improving the performance of tracheal tubes in reducing microaspiration is one potential means to prevent VAP. The aim of this narrative review is to discuss recent findings on the impact of tracheal tube design on VAP prevention. Several randomized controlled studies have reported that subglottic secretion drainage (SSD) is efficient in VAP prevention. Meta-analyses have reported conflicting results regarding the impact of SSD on duration of mechanical ventilation, and one animal study raised concern about SSD-related tracheal lesions. However, this measure appears to be cost-effective. Therefore, SSD should probably be used in all patients with expected duration of mechanical ventilation > 48 h. Three randomized controlled trials have shown that tapered-cuff tracheal tubes are not useful to prevent VAP and should probably not be used in critically ill patients. Further studies are required to confirm the promising effects of continuous control of cuff pressure, polyurethane-cuffed, silver-coated, and low-volume low-pressure tracheal tubes. There is moderate evidence for the use of SSD and strong evidence against the use of tapered-cuff tracheal tubes in critically ill patients for VAP prevention. However, more data on the safety and cost-effectiveness of these measures are needed. Other tracheal tube-related preventive measures require further investigation. Copyright © 2017 by Daedalus Enterprises.

  17. Boiling and condensation in microfin tubes

    NASA Astrophysics Data System (ADS)

    Schlager, Lynn M.

    A general overview of microfin tubes and their applications is presented. Manufacturing processes, commercial availability, experimental heat transfer, and pressure drop data for various refrigerants (including alternative refrigerants and refrigerant-oil mixtures), physical mechanisms of enhancement, and the incorporation of microfin tubes in common heat exchanger configurations are discussed. Microfin tubes, also known by various trade names, are characterized by numerous small fins which typically spiral down the inside wall of tubes at angles ranging from 10 to 30 degrees. The number of fins ranges from 48 to 70 with typical fin heights of 0.12 to 0.30 mm (fin height generally less than 3 percent of the inside diameter of the tube). Fin shapes may vary and the inside surface area of microfin tubes is 10 to 70 percent greater than the area of equivalent smooth tubes. Heat transfer can be enhanced by up to a factor of three with microfin tubes.

  18. Low-pressure water-cooled inductively coupled plasma torch

    DOEpatents

    Seliskar, C.J.; Warner, D.K.

    1984-02-16

    An inductively coupled plasma torch is provided which comprises an inner tube, including a sample injection port to which the sample to be tested is supplied and comprising an enlarged central portion in which the plasma flame is confined; an outer tube surrounding the inner tube and containing water therein for cooling the inner tube, the outer tube including a water inlet port to which water is supplied and a water outlet port spaced from the water inlet port and from which water is removed after flowing through the outer tube; and an rf induction coil for inducing the plasma in the gas passing into the tube through the sample injection port. The sample injection port comprises a capillary tube including a reduced diameter orifice, projecting into the lower end of the inner tube. The water inlet is located at the lower end of the outer tube and the rf heating coil is disposed around the outer tube above and adjacent to the water inlet.

  19. Improvement of pump tubes for gas guns and shock tube drivers

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.

    1990-01-01

    In a pump tube, a gas is mechanically compressed, producing very high pressures and sound speeds. The intensely heated gas produced in such a tube can be used to drive light gas guns and shock tubes. Three concepts are presented that have the potential to allow substantial reductions in the size and mass of the pump tube to be achieved. The first concept involves the use of one or more diaphragms in the pump tube, thus replacing a single compression process by multiple, successive compressions. The second concept involves a radical reduction in the length-to-diameter ratio of the pump tube and the pump tube piston. The third concept involves shock heating of the working gas by high explosives in a cyclindrical geometry reusable device. Preliminary design analyses are performed on all three concepts and they appear to be quite feasible. Reductions in the length and mass of the pump tube by factors up to about 11 and about 7, respectively, are predicted, relative to a benchmark conventional pump tube.

  20. Low-pressure water-cooled inductively coupled plasma torch

    DOEpatents

    Seliskar, Carl J.; Warner, David K.

    1988-12-27

    An inductively coupled plasma torch is provided which comprises an inner tube, including a sample injection port to which the sample to be tested is supplied and comprising an enlarged central portion in which the plasma flame is confined; an outer tube surrounding the inner tube and containing water therein for cooling the inner tube, the outer tube including a water inlet port to which water is supplied and a water outlet port spaced from the water inlet port and from which water is removed after flowing through the outer tube; and an r.f. induction coil for inducing the plasma in the gas passing into the tube through the sample injection port. The sample injection port comprises a capillary tube including a reduced diameter orifice, projecting into the lower end of the inner tube. The water inlet is located at the lower end of the outer tube and the r.f. heating coil is disposed around the outer tube above and adjacent to the water inlet.

Top