Sample records for previously published laser

  1. Improvement of thermal management in the composite Yb:YAG/YAG thin-disk laser

    NASA Astrophysics Data System (ADS)

    Kuznetsov, I. I.; Mukhin, I. B.; Palashov, O. V.

    2016-04-01

    To improve the thermal management in the composite Yb:YAG/YAG thin-disk laser a new design of laser head is developed. Thermal-induced phase distortions, small signal gain and lasing in the upgraded laser head are investigated and compared with previously published results. A substantial decrease of the thermal lens optical power and phase aberrations and increase of the laser slope efficiency are observed. A continuous-wave laser with 440 W average power and 44% slope efficiency is constructed.

  2. The space-dependent model and output characteristics of intra-cavity pumped dual-wavelength lasers

    NASA Astrophysics Data System (ADS)

    He, Jin-Qi; Dong, Yuan; Zhang, Feng-Dong; Yu, Yong-Ji; Jin, Guang-Yong; Liu, Li-Da

    2016-01-01

    The intra-cavity pumping scheme which is used to simultaneously generate dual-wavelength lasers was proposed and published by us and the space-independent model of quasi-three-level and four-level intra-cavity pumped dual-wavelength lasers was constructed based on this scheme. In this paper, to make the previous study more rigorous, the space-dependent model is adopted. As an example, the output characteristics of 946 nm and 1064 nm dual-wavelength lasers under the conditions of different output mirror transmittances are numerically simulated by using the derived formula and the results are nearly identical to what was previously reported.

  3. Phase Aberrations And Beam Cleanup Techniques In Carbon-Dioxide Laser Fusion Systems

    NASA Astrophysics Data System (ADS)

    Viswanathan, V. K.

    1981-12-01

    This paper describes the various carbon dioxide laser fusion systems at Los Alamos from the point of view of an optical designer. The types of phase aberrations present in these systems, as well as the beam cleanup techniques that can be used to improve the beam optical quality, are discussed. As this is a review article, some previously published results are also used where relevant.

  4. Substituting an Inexpensive Function Generator for the Pulsed Laser in the Experiment "Laser Measurement of the Speed of Sound in Gases"

    ERIC Educational Resources Information Center

    Epstein, Mark G.; Laszlo, Matthew W.; Mayer, Steven G.

    2010-01-01

    We present an adaptation to an experiment previously published in this "Journal". The experiment was designed to determine the heat capacity ratios of gases by measuring the speed of sound using a modified Kundt's tube. The experiment yielded excellent results for all of the gases and gas mixtures measured. Although elegant in its simplicity, it…

  5. New application of the long-pulsed Nd-YAG laser as an ablative resurfacing tool for skin rejuvenation: a 7-year study.

    PubMed

    Alshami, Mohammad Ali

    2013-09-01

    Carbon dioxide (CO2 ) and erbium-yttrium aluminum garnet (Er-YAG) lasers are the gold standards in ablative skin resurfacing. Neodymium-doped yttrium aluminum garnet (Nd-YAG) laser is considered a nonablative skin resurfacing laser whose usage is limited due to its high cost. To assess the efficacy and safety of Nd-YAG as an ablative resurfacing laser and to compare the results with those previously published for CO2 and Erbium-YAG lasers. A total of 296 patients (251 female and 45 male) with Fitzpatrick skin types III-IV and dermatological conditions amenable to ablative skin resurfacing participated in this study. Nd-YAG laser parameters assessed were wavelength (1064 nm), pulse duration (5 ms), fluence (10 J/cm(2) ), and spot size (8-10 mm). Efficacy of Nd-YAG laser was assessed by comparing pre- and posttreatment photographs. An improvement of 30-80% was observed in treated patients. The degree of improvement correlated positively with the number of laser sessions. The most common side effect was hyperpigmentation. Other side effects were less common and mild in intensity compared with published results for gold standard ablative lasers. Not only was the Nd-YAG laser found to be as effective as Er-YAG and CO2 lasers, but treated patients also had shorter recovery and treatment times, and at lower cost. © 2013 Wiley Periodicals, Inc.

  6. Propulsion of a flat tin target with pulsed CO2 laser radiation: measurements using a ballistic pendulum

    NASA Astrophysics Data System (ADS)

    Lakatosh, B. V.; Abramenko, D. B.; Ivanov, V. V.; Medvedev, V. V.; Krivtsun, V. M.; Koshelev, K. N.; Yakunin, A. M.

    2018-01-01

    The recoil momentum transfer produced by irradiation of a flat tin (Sn) target with pulses of high-power CO2 laser with intensity ranging from 107 to 1010 W cm-2 has been studied. Momentum measurements were performed using a ballistic pendulum, capable of measuring momenta as small as 0.001 g · cm s-1 . It has been established that the recoil momentum monotonically increases with the laser energy and asymptotically reaches the power scaling law p ∼ Iα with α = 0.96 +/- 0.07 . Results are compared with previously published theoretical studies.

  7. Comparing quantitative values of two generations of laser-assisted indocyanine green dye angiography systems: can we predict necrosis?

    PubMed

    Phillips, Brett T; Fourman, Mitchell S; Rivara, Andrew; Dagum, Alexander B; Huston, Tara L; Ganz, Jason C; Bui, Duc T; Khan, Sami U

    2014-01-01

    Several devices exist today to assist the intraoperative determination of skin flap perfusion. Laser-Assisted Indocyanine Green Dye Angiography (LAICGA) has been shown to accurately predict mastectomy skin flap necrosis using quantitative perfusion values. The laser properties of the latest LAICGA device (SPY Elite) differ significantly from its predecessor system (SPY 2001), preventing direct translation of previous published data. The purpose of this study was to establish a mathematical relationship of perfusion values between these 2 devices. Breast reconstruction patients were prospectively enrolled into a clinical trial where skin flap evaluation and excision was based on quantitative SPY Q values previously established in the literature. Initial study patients underwent mastectomy skin flap evaluation using both SPY systems simultaneously. Absolute perfusion unit (APU) values at identical locations on the breast were then compared graphically. 210 data points were identified on the same patients (n = 4) using both SPY systems. A linear relationship (y = 2.9883x + 12.726) was identified with a high level or correlation (R(2) = 0.744). Previously published values using SPY 2001 (APU 3.7) provided a value of 23.8 APU on the SPY Elite. In addition, postoperative necrosis in these patients correlated to regions of skin identified with the SPY Elite with APU less than 23.8. Intraoperative comparison of LAICGA systems has provided direct correlation of perfusion values predictive of necrosis that were previously established in the literature. An APU value of 3.7 from the SPY 2001 correlates to a SPY Elite APU value of 23.8.

  8. Comparing Quantitative Values of Two Generations of Laser-Assisted Indocyanine Green Dye Angiography Systems: Can We Predict Necrosis?

    PubMed Central

    Fourman, Mitchell S.; Rivara, Andrew; Dagum, Alexander B.; Huston, Tara L.; Ganz, Jason C.; Bui, Duc T.; Khan, Sami U.

    2014-01-01

    Objective: Several devices exist today to assist the intraoperative determination of skin flap perfusion. Laser-Assisted Indocyanine Green Dye Angiography (LAICGA) has been shown to accurately predict mastectomy skin flap necrosis using quantitative perfusion values. The laser properties of the latest LAICGA device (SPY Elite) differ significantly from its predecessor system (SPY 2001), preventing direct translation of previous published data. The purpose of this study was to establish a mathematical relationship of perfusion values between these 2 devices. Methods: Breast reconstruction patients were prospectively enrolled into a clinical trial where skin flap evaluation and excision was based on quantitative SPY Q values previously established in the literature. Initial study patients underwent mastectomy skin flap evaluation using both SPY systems simultaneously. Absolute perfusion unit (APU) values at identical locations on the breast were then compared graphically. Results: 210 data points were identified on the same patients (n = 4) using both SPY systems. A linear relationship (y = 2.9883x + 12.726) was identified with a high level or correlation (R2 = 0.744). Previously published values using SPY 2001 (APU 3.7) provided a value of 23.8 APU on the SPY Elite. In addition, postoperative necrosis in these patients correlated to regions of skin identified with the SPY Elite with APU less than 23.8. Conclusion: Intraoperative comparison of LAICGA systems has provided direct correlation of perfusion values predictive of necrosis that were previously established in the literature. An APU value of 3.7 from the SPY 2001 correlates to a SPY Elite APU value of 23.8. PMID:25525483

  9. The influence of stripe width on the threshold current of double-heterojunction lasers

    NASA Technical Reports Server (NTRS)

    Ladany, I.

    1977-01-01

    Experimental measurements of the threshold current of oxide-isolated stripe laser as a function of stripe width and p-layer resistivity are presented. A calculation of the influence of carrier outdiffusion has been made, including the effect of current leakage beyond the stripe edges. The calculated threshold increase is in substantial agreement with experiment for stripe widths down to about 10 microns. The data also yield an effective diffusion length of about 7 microns for the lasers studied. Deviations between experimental and calculated thresholds occurring at stripe widths of 4-6 microns are represented by an empirical curve which is compared with previously published calculations of threshold gain.

  10. Laser therapy for the treatment of arthritic knees: a clinical study

    NASA Astrophysics Data System (ADS)

    Kahn, F.; Liboro, R.; Saraga, F.

    2010-02-01

    In a follow-up clinical study to our previously published 2006 SPIE conference proceeding, we analyzed a cross-section of patients treated for a variety of knee problems that present at our Meditech Laser Rehabilitation Clinics on a daily basis. Of the 98 patients with knee pathologies included in this study, 63% presented with degenerative osteoarthritis. On average 11 treatments, each 30-45 minutes in duration, were administered for the individual patient resulting in a significant improvement rate in excess of 92%. Laser Therapy is active at both the cellular and systemic levels activating a variety of mechanisms including cartilage regeneration, DNA synthesis, improved microcirculation and an analgesic and anti-inflammatory effect.

  11. In-situ characterization of laser-powder interaction and cooling rates through high-speed imaging of powder bed fusion additive manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scipioni Bertoli, Umberto; Guss, Gabe; Wu, Sheldon

    We report detailed understanding of the complex melt pool physics plays a vital role in predicting optimal processing regimes in laser powder bed fusion additive manufacturing. In this work, we use high framerate video recording of Selective Laser Melting (SLM) to provide useful insight on the laser-powder interaction and melt pool evolution of 316 L powder layers, while also serving as a novel instrument to quantify cooling rates of the melt pool. The experiment was performed using two powder types – one gas- and one water-atomized – to further clarify how morphological and chemical differences between these two feedstock materialsmore » influence the laser melting process. Finally, experimentally determined cooling rates are compared with values obtained through computer simulation, and the relationship between cooling rate and grain cell size is compared with data previously published in the literature.« less

  12. In-situ characterization of laser-powder interaction and cooling rates through high-speed imaging of powder bed fusion additive manufacturing

    DOE PAGES

    Scipioni Bertoli, Umberto; Guss, Gabe; Wu, Sheldon; ...

    2017-09-21

    We report detailed understanding of the complex melt pool physics plays a vital role in predicting optimal processing regimes in laser powder bed fusion additive manufacturing. In this work, we use high framerate video recording of Selective Laser Melting (SLM) to provide useful insight on the laser-powder interaction and melt pool evolution of 316 L powder layers, while also serving as a novel instrument to quantify cooling rates of the melt pool. The experiment was performed using two powder types – one gas- and one water-atomized – to further clarify how morphological and chemical differences between these two feedstock materialsmore » influence the laser melting process. Finally, experimentally determined cooling rates are compared with values obtained through computer simulation, and the relationship between cooling rate and grain cell size is compared with data previously published in the literature.« less

  13. Application of ultra-high energy hollow cathode helium-silver laser (224.3 nm) as Jc's, grain size surface's promoter for Ir-optimally doped-Mg0.94Ir0.06B2 superconductors

    NASA Astrophysics Data System (ADS)

    Elsabawy, Khaled M.; Fallatah, Ahmed M.; Alharthi, Salman S.

    2018-07-01

    For the first time high energy Helium-Silver laser which belongs to the category of metal-vapor lasers applied as microstructure promoter for optimally Ir-doped-MgB2sample. The Ir-optimally doped-Mg0.94Ir 0.06B2 superconducting sample was selected from previously published article for one of authors themselves. The samples were irradiated by a three different doses 1, 2 and 3 h from an ultrahigh energy He-Ag-Laser with average power of 103 W/cm2 at distance of 3 cm. Superconducting measurements and micro-structural features were investigated as function of He-Ag Laser irradiation doses. Results indicated that irradiations via an ultrahigh energy He-Ag-Laser promoted grains to lower sizes and consequently measured Jc's values enhanced and increased. Furthermore Tc-offsets for all irradiated samples are better than non-irradiated Mg0.94Ir 0.06B2.

  14. Targeting telomere-containing chromosome ends with a near-infrared femtosecond laser to study the activation of the DNA damage response and DNA damage repair pathways

    PubMed Central

    Silva, Bárbara Alcaraz; Stambaugh, Jessica R.

    2013-01-01

    Abstract. Telomeres are at the ends of chromosomes. Previous evidence suggests that laser-induced deoxyribose nucleic acid (DNA) breaks at chromosome ends during anaphase results in delayed cytokinesis. A possible explanation for this delay is that the DNA damage response (DDR) mechanism has been activated. We describe a live imaging method to study the effects of DDR activation following focal point near-infrared femtosecond laser microirradiation either at a single chromosome end or at a chromosome arm in mitotic anaphase cells. Laser microirradiation is used in combination with dual fluorescent labeling to monitor the co-localization of double-strand break marker γH2AX along with the DDR factors in PtK2 (Potorous tridactylus) cells. Laser-induced DNA breaks in chromosome ends as well as in chromosome arms results in recruitment of the following: poly(ADP-ribose) polymerase 1, checkpoint sensors (p-Chk1, p-Chk2), DNA repair protein Ku70/Ku80, and proliferating cell nuclear antigen. However, phosphorylated p53 at serine 15 is detected only at chromosome ends and not at chromosome arms. Full activation of DDR on damaged chromosome ends may explain previously published results that showed the delay of cytokinesis. PMID:24064949

  15. A review of the development of portable laser induced breakdown spectroscopy and its applications

    NASA Astrophysics Data System (ADS)

    Rakovský, J.; Čermák, P.; Musset, O.; Veis, P.

    2014-11-01

    In this review, we present person-transportable laser induced breakdown spectroscopy (LIBS) devices that have previously been developed and reported in the literature as well as their applications. They are compared with X-ray fluorescent (XRF) devices, which represent their strongest competition. Although LIBS devices have advantages over XRF devices, such as sensitivity to the light elements, high spatial resolution and the possibility to distinguish between different layers of the sample, there are also disadvantages and both are discussed here. Furthermore, the essential portable LIBS instrumentation (laser, spectrograph and detector) is presented, and published results related to new laser sources (diode-pumped solid-state, microchip and fiber lasers) used in LIBS are overviewed. Compared to conventional compact flashlamp pumped solid-state lasers, the new laser sources provide higher repetition rates, higher efficiency (less power consumption) and higher beam quality, resulting in higher fluences, even for lower energies, and could potentially increase the figure of merit of portable LIBS instruments. Compact spectrometers used in portable LIBS devices and their parts (spectrograph, detector) are also discussed.

  16. Hyperfine structure measurements of neutral vanadium by laser-induced fluorescence spectroscopy in the wavelength range from 750 nm to 860 nm

    NASA Astrophysics Data System (ADS)

    Başar, Gü.; Güzelçimen, F.; Öztürk, I. K.; Er, A.; Bingöl, D.; Kröger, S.; Başar, Gö.

    2017-11-01

    The hyperfine structure of 57 spectral lines of neutral vanadium has been investigated using a hollow cathode lamp by laser-induced fluorescence spectroscopy in the wavelength range from 750 nm to 860 nm. New magnetic dipole hyperfine structure constants A have been determined for 14 atomic energy levels and new electric quadrupole hyperfine structure constants B for two levels. Additionally previously published hyperfine structure constants A of 56 levels have been measured again. In five cases, the old A values have been rejected and replaced by improved values.

  17. From the Editors

    NASA Astrophysics Data System (ADS)

    Pashinin, Pavel P.; Yermachenko, Valery M.; Yevseyev, Igor V.

    2010-01-01

    Dear readers and authors, This preface opens the seventh volume of the journal Laser Physics Letters. We are happy to inform you that the first six years have been quite successful for the journal. In the years 2004-2009, Laser Physics Letters published around 700 original articles written by scientists from 55 countries. During these years, in addition to original articles, Laser Physics Letters published about 40 brief review invited articles written by top scientists from different countries. These review articles provide readers a unique possibility of being timely informed on the current research in different fields of laser physics and on the most fresh and important results in these fields. The brief review articles, published in Laser Physics Letters, have attracted high attention of readers and are extensively cited. Some of these review articles have been cited more than 60 times in the main journals covered by ISI Web of Science. This shows the great importance and attractiveness of the published brief review invited articles for the laser physics community. We certainly understand that such a success is due to the following reasons. First of all, the authors of Laser Physics Letters are the top scientists in the field of laser physics from all over the world. And, second, all 28 members of the Editorial Board, representing 13 countries, are strongly committed to do all their best for making the journal an excellent forum for the laser physics community. Laser Physics Letters publishes pioneering articles in different fields of laser physics. In order to be accessible to a wide auditorium, the papers should clearly point out the main contributions of the article to the field of research and their relation to other articles treating the topic. A well-written introduction is a prerequisite for a good paper. This allows the readers to better judge on the contribution of the article and to objectively evaluate the presented results. We are proud to announce that the 2008 impact factor of Laser Physics Letters reached 3.779. This is a rather good achievement for a journal published only six years. It is important to stress that each year Laser Physics Letters publishes about 150 articles. Therefore, the high impact factor is due not to the meager amount of published papers but really to the high quality of them. It is also very important that the accepted articles are displayed on the website in the section Early View just in two weeks after their acceptance. The early-view articles are already given their publication date and DOI. It makes them immediately accessible for readers and, respectively, for citation. The procedure of refereeing the submitted manuscripts is known to be of paramount importance for any journal. The refereeing process on Laser Physics Letters is unique in two points. First, it is very fast, with the standard time of reviewing about one week after the manuscript submission. Second, the refereeing is done exclusively by the top scientists in the respective fields of laser physics. Therefore, we hope that Laser Physics Letters has produced no biased or unjustified referee reports, which are so common for many journals. The Laser Physics Letters Editorial Board expresses deep gratitude to all referees of the journal. A well-organized and qualified work of the technical department of the journal is also of great importance. We are happy that this department always guarantees the highest quality of the manuscripts camera-ready copies and their figures, which has been noticed by many authors. It is worth mentioning the close collaboration of Laser Physics Letters with the annual International Laser Physics Workshop (LPHYS). The sequel of these Workshops was launched in 1992 by the Nobel Prize winner A.M. Prokhorov. There have already been 18 of these Workshops, whose history can be traced on the website www.lasphys.com. The eighteenth Workshop was held from July 13 to July 17 in Barcelona, Spain. About 580 participants from 37 countries took part in the Workshop. We hope that the next Workshop LPHYS'10, which will be held from July 5 to July 9, 2010, in Foz do Iguaçu, Brazil, will also be as successful as the previous workshops. More detailed information on LPHYS'10 is given in the next page. Once again, the Editorial Board of Laser Physics Letters thanks the authors, readers, and referees of Laser Physics Letters. We do hope that our joint work will be beneficial for the development of the laser physics science. Sincerely Yours,

  18. Enhanced laser-energy coupling to dense plasmas driven by recirculating electron currents

    NASA Astrophysics Data System (ADS)

    Gray, R. J.; Wilson, R.; King, M.; Williamson, S. D. R.; Dance, R. J.; Armstrong, C.; Brabetz, C.; Wagner, F.; Zielbauer, B.; Bagnoud, V.; Neely, D.; McKenna, P.

    2018-03-01

    The absorption of laser energy and dynamics of energetic electrons in dense plasma is fundamental to a range of intense laser-driven particle and radiation generation mechanisms. We measure the total reflected and scattered laser energy as a function of intensity, distinguishing between the influence of pulse energy and focal spot size on total energy absorption, in the interaction with thin foils. We confirm a previously published scaling of absorption with intensity by variation of laser pulse energy, but find a slower scaling when changing the focal spot size. 2D particle-in-cell simulations show that the measured differences arise due to energetic electrons recirculating within the target and undergoing multiple interactions with the laser pulse, which enhances absorption in the case of large focal spots. This effect is also shown to be dependent on the laser pulse duration, the target thickness and the electron beam divergence. The parameter space over which this absorption enhancement occurs is explored via an analytical model. The results impact our understanding of the fundamental physics of laser energy absorption in solids and thus the development of particle and radiation sources driven by intense laser–solid interactions.

  19. One-kilohertz eye tracker and active intraoperative torsion detection in the NIDEK CXIII and Quest excimer lasers.

    PubMed

    Waring, George O

    2009-10-01

    To describe recent technological additions to the NIDEK CXIII and Quest excimer lasers. A summary article with data from previous published studies outlining the benefits of newer technology. The addition of a 1-kHz infrared eye tracker decreased the spread of laser spot placement from a mean of 228.79 microm without a tracker to 38.47 microm with the eye tracker. The addition of real-time torsion error correction produced a statistically significantly lower cylinder dispersion, mean manifest refractive cylinder, and error of angle postoperatively in eyes that underwent LASIK. The incorporation of an ultrahigh speed eye tracker and active cyclotorsion correction surpasses the minimal technology criteria required for accurate wavefront-based ablations. Copyright 2009, SLACK Incorporated.

  20. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK.

    PubMed

    Lee, Jimmy K; Chuck, Roy S; Park, Choul Yong

    2015-07-01

    Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.

  1. Origin of temperature plateaus in laser-heated diamond anvil cell experiments

    NASA Astrophysics Data System (ADS)

    Geballe, Zachary M.; Jeanloz, Raymond

    2012-06-01

    Many high-pressure high-temperature studies using laser-heated diamond cells have documented plateaus in the increase of temperature with increasing laser power or with time. By modeling heat transfer in typical laser-heated diamond anvil cell experiments, we demonstrate that latent heat due to melting or other phase transformation is unlikely to be the source of observed plateaus in any previously published studies, regardless of whether pulsed or continuous lasers were used. Rather, large increases (˜10-fold) in thermal conductivity can explain some of the plateaus, and modest increases in reflectivity (tens of percent) can explain any or all of them. Modeling also shows that the sub-microsecond timescale of heating employed in recent pulsed heating experiments is fast enough compared to heat transport into and through typical insulations, but too slow compared to heat transport into metallic laser absorbers themselves to allow the detection of a large plateau due to latent heat of fusion. Four new designs are suggested for future experiments that could use the simple observation of a latent heat-induced plateau to provide reliable high-pressure melting data.

  2. Fast and slowly evolving vector solitons in mode-locked fibre lasers.

    PubMed

    Sergeyev, Sergey V

    2014-10-28

    We report on a new vector model of an erbium-doped fibre laser mode locked with carbon nanotubes. This model goes beyond the limitations of the previously used models based on either coupled nonlinear Schrödinger or Ginzburg-Landau equations. Unlike the previous models, it accounts for the vector nature of the interaction between an optical field and an erbium-doped active medium, slow relaxation dynamics of erbium ions, linear birefringence in a fibre, linear and circular birefringence of a laser cavity caused by in-cavity polarization controller and light-induced anisotropy caused by elliptically polarized pump field. Interplay of aforementioned factors changes coherent coupling of two polarization modes at a long time scale and so results in a new family of vector solitons (VSs) with fast and slowly evolving states of polarization. The observed VSs can be of interest in secure communications, trapping and manipulation of atoms and nanoparticles, control of magnetization in data storage devices and many other areas. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmlid, Leif, E-mail: holmlid@chem.gu.se

    Previous results from laser-induced processes in ultra-dense deuterium D(0) give conclusive evidence for ejection of neutral massive particles with energy >10 MeV u{sup −1}. Such particles can only be formed from nuclear processes like nuclear fusion at the low laser intensity used. Heat generation is of interest for future fusion energy applications and has now been measured by a small copper (Cu) cylinder surrounding the laser target. The temperature rise of the Cu cylinder is measured with an NTC resistor during around 5000 laser shots per measured point. No heating in the apparatus or the gas feed is normally used.more » The fusion process is suboptimal relative to previously published studies by a factor of around 10. The small neutral particles H{sub N}(0) of ultra-dense hydrogen (size of a few pm) escape with a substantial fraction of the energy. Heat loss to the D{sub 2} gas (at <1 mbar pressure) is measured and compensated for under various conditions. Heat release of a few W is observed, at up to 50% higher energy than the total laser input thus a gain of 1.5. This is uniquely high for the use of deuterium as fusion fuel. With a slightly different setup, a thermal gain of 2 is reached, thus clearly above break-even for all neutronicity values possible. Also including the large kinetic energy which is directly measured for MeV particles leaving through a small opening gives a gain of 2.3. Taking into account the lower efficiency now due to the suboptimal fusion process, previous studies indicate a gain of at least 20 during long periods.« less

  4. Fully automated laser ray tracing system to measure changes in the crystalline lens GRIN profile.

    PubMed

    Qiu, Chen; Maceo Heilman, Bianca; Kaipio, Jari; Donaldson, Paul; Vaghefi, Ehsan

    2017-11-01

    Measuring the lens gradient refractive index (GRIN) accurately and reliably has proven an extremely challenging technical problem. A fully automated laser ray tracing (LRT) system was built to address this issue. The LRT system captures images of multiple laser projections before and after traversing through an ex vivo lens. These LRT images, combined with accurate measurements of the lens geometry, are used to calculate the lens GRIN profile. Mathematically, this is an ill-conditioned problem; hence, it is essential to apply biologically relevant constraints to produce a feasible solution. The lens GRIN measurements were compared with previously published data. Our GRIN retrieval algorithm produces fast and accurate measurements of the lens GRIN profile. Experiments to study the optics of physiologically perturbed lenses are the future direction of this research.

  5. Fully automated laser ray tracing system to measure changes in the crystalline lens GRIN profile

    PubMed Central

    Qiu, Chen; Maceo Heilman, Bianca; Kaipio, Jari; Donaldson, Paul; Vaghefi, Ehsan

    2017-01-01

    Measuring the lens gradient refractive index (GRIN) accurately and reliably has proven an extremely challenging technical problem. A fully automated laser ray tracing (LRT) system was built to address this issue. The LRT system captures images of multiple laser projections before and after traversing through an ex vivo lens. These LRT images, combined with accurate measurements of the lens geometry, are used to calculate the lens GRIN profile. Mathematically, this is an ill-conditioned problem; hence, it is essential to apply biologically relevant constraints to produce a feasible solution. The lens GRIN measurements were compared with previously published data. Our GRIN retrieval algorithm produces fast and accurate measurements of the lens GRIN profile. Experiments to study the optics of physiologically perturbed lenses are the future direction of this research. PMID:29188093

  6. In-situ sequential laser transfer and laser reduction of graphene oxide films

    NASA Astrophysics Data System (ADS)

    Papazoglou, S.; Petridis, C.; Kymakis, E.; Kennou, S.; Raptis, Y. S.; Chatzandroulis, S.; Zergioti, I.

    2018-04-01

    Achieving high quality transfer of graphene on selected substrates is a priority in device fabrication, especially where drop-on-demand applications are involved. In this work, we report an in-situ, fast, simple, and one step process that resulted in the reduction, transfer, and fabrication of reduced graphene oxide-based humidity sensors, using picosecond laser pulses. By tuning the laser illumination parameters, we managed to implement the sequential printing and reduction of graphene oxide flakes. The overall process lasted only a few seconds compared to a few hours that our group has previously published. DC current measurements, X-Ray Photoelectron Spectroscopy, X-Ray Diffraction, and Raman Spectroscopy were employed in order to assess the efficiency of our approach. To demonstrate the applicability and the potential of the technique, laser printed reduced graphene oxide humidity sensors with a limit of detection of 1700 ppm are presented. The results demonstrated in this work provide a selective, rapid, and low-cost approach for sequential transfer and photochemical reduction of graphene oxide micro-patterns onto various substrates for flexible electronics and sensor applications.

  7. Sealing Penetrating Eye Injuries Using Photoactivated Bonding

    DTIC Science & Technology

    2012-09-01

    membrane over a penetrating corneal injury with photochemical tissue bonding ( PTB )(Task 1), we had proposed to directly bond, with PTB , the edges of...wounds with irregular shapes which mimic traumatic wounds. We had previously demonstrated that PTB effectively sealed linear incisional wounds in...developed for sealing eyelid lacerations with PTB was submitted in Year 2 and was published in Year 3 in Lasers in Surgery and Medicine. It is listed in

  8. A pilot study of laser energy transmission through bone and gingiva.

    PubMed

    Ng, Doreen Y; Chan, Ambrose K; Dalci, Oyku; Petocz, Peter; Papadopoulou, Alexandra K; Darendeliler, M Ali

    2018-06-20

    The use of low-level laser therapy is growing in the field of dentistry especially in orthodontics to speed up tooth movement and in implantology to aid osseointegration. In these dental applications, the laser energy needs to penetrate through the periodontium to the target site to stimulate photobiomodulation. The percentage of energy loss when laser is transmitted through the periodontium has not been previously studied. With the use of an 808-nanometer diode laser, the aim was to investigate the percentage loss of laser energy when transmitted through the periodontium to the extraction socket. The percentage energy loss of an 808-nm diode laser through the periodontium was measured in 27 tooth sockets by using a specifically designed photodiode ammeter. For each millimeter of increased bone thickness there was 6.81% reduction in laser energy (95% confidence interval, 5.02% to 8.60%). The gingival thickness had no statistically significant effect on energy penetration. Energy penetration depends markedly on bone thickness and is independent of gingival thickness. To the best of the authors' knowledge, this study is one of the first to investigate laser penetration through the periodontium. Evidence from this study showed that laser energy penetration through the periodontium is markedly affected by bone thickness but less so by gingival thickness. Clinicians need to be aware of the biological factors that could affect laser energy penetration to the target site and adjust their laser dosages accordingly. These findings may guide dental practitioners in selecting the appropriate laser dosage parameters for low-level laser therapy. Copyright © 2018 American Dental Association. Published by Elsevier Inc. All rights reserved.

  9. Professor Igor Yevseyev: In Memoriam Professor Igor Yevseyev: In Memoriam

    NASA Astrophysics Data System (ADS)

    2012-06-01

    Dear readers and authors, June 3, 2012 will mark five months since Professor Igor Yevseyev, Deputy Editor-in-Chief of both journals Laser Physics and Laser Physics Letters passed away, suddenly and unexpectedly. He was 67. Born in Moscow, he entered one of the world's best schools of physics, Moscow Engineering Physics Institute (MEPhI). With this renowned educational and research institution he bonded an alliance for his entire life, starting as an undergraduate student in the Department of Theoretical Physics and later continued as graduate student, assistant professor, associated professor, and full professor in the same department, a rare accomplishment of a person. All those years he retained the love of his life—the love for physics. He worked tirelessly as a teacher and scholar in this captivating field of knowledge. Professor Yevseyev was one of the founders of the international journal of Laser Physics in 1990, the first academic English language journal published in the former USSR. Later, in 2004, the second journal, Laser Physics Letters was brought to the forum of global laser physics community. The idea behind this new title was Professor Yevseyev's initiative to reach the readers and participants with new pioneering and break-through research results more rapidly. His leadership and indefatigable dedication to the quality of published materials made it possible that this journal reached international recognition in a few short years. Still, in order to attract even more attention of potential contributors and readers, Professor Yevseyev originally proposed to conduct the International Laser Physics Workshop (LPHYS) on the annual basis. Since 1992 the Workshop has been conducted every year, each year in a different country. As in all previous years, Professor Yevseyev was the key organizer of this year's workshop in Calgary, Canada. Sadly, this workshop will take place without him. Editorial Board

  10. PREFACE: 21st International Conference on Laser Spectroscopy - ICOLS 2013

    NASA Astrophysics Data System (ADS)

    Budker, Dmitry; Häffner, Hartmut; Müller, Holger

    2013-12-01

    The 21st International Conference on Laser Spectroscopy (ICOLS) took place at Berkeley, California on 9-14 June 2013. Following the tradition of previous meetings in this series, the conference featured about thirty invited talks broadly covering this burgeoning field of science that refuses to show any sign of saturation after more than half a century of continuous boom. In addition to the invited talks, there were two informative poster sessions, where the more than 300 ICOLS participants had an opportunity to exchange the latest scientific news and ideas while enjoying the gorgeous view of the San Francisco Bay from the vista of the Claremont Hotel, the meeting's venue. The heights of the cultural program of the meeting were excursions to several of the Bay Area gems (including the Lick observatory), as well as the conference banquet where the participants were treated to addresses by an inventor of the laser Professor Charles H Townes, a nonlinear optics pioneer Professor Erwin L Hahn, and one of the previous ICOLS chairs Professor Y R Shen. While the field of Laser Spectroscopy and the series of the bi-annual ICOLS meetings are as 'healthy' as one could imagine, the same cannot be said about the concept of published conference proceedings. With new ways to publish scientific articles and preprints, submitting papers to conference proceedings seems to be rapidly losing popularity. For this meeting, the great interest in attendance and opportunities to present is sharply contrasted with a somewhat sluggish response to the call for submission of the proceedings papers. The present collection represents a dozen or so contributions from the 'hero' invited speakers, to whom we are deeply grateful for submitting their work. We hope that this selection will faithfully convey to the readers the excitement of modern laser spectroscopy. In addition to these papers, we draw the reader's attention to the audio recordings and selected viewgraphs from the invited talks, and videos of the reception and banquet presentations available at the conference web site https://icols.berkeley.edu/. On behalf of the organizing and program committees, Berkeley, October 2013 Dmitry Budker, Hartmut Häffner, and Holger Müller

  11. Generalized filtering of laser fields in optimal control theory: application to symmetry filtering of quantum gate operations

    NASA Astrophysics Data System (ADS)

    Schröder, Markus; Brown, Alex

    2009-10-01

    We present a modified version of a previously published algorithm (Gollub et al 2008 Phys. Rev. Lett.101 073002) for obtaining an optimized laser field with more general restrictions on the search space of the optimal field. The modification leads to enforcement of the constraints on the optimal field while maintaining good convergence behaviour in most cases. We demonstrate the general applicability of the algorithm by imposing constraints on the temporal symmetry of the optimal fields. The temporal symmetry is used to reduce the number of transitions that have to be optimized for quantum gate operations that involve inversion (NOT gate) or partial inversion (Hadamard gate) of the qubits in a three-dimensional model of ammonia.

  12. 186 K Operation of Terahertz Quantum-Cascade Lasers Based on a Diagonal Design

    NASA Technical Reports Server (NTRS)

    Kumar, Sushil; Hu, Qing; Reno, John L.

    2009-01-01

    Resonant-phonon terahertz quantum-cascade lasers operating up to a heat-sink temperature of 186 K are demonstrated. This record temperature performance is achieved based on a diagonal design, with the objective to increase the upper-state lifetime and therefore the gain at elevated temperatures. The increased diagonality also lowers the operating current densities by limiting the flow of parasitic leakage current. Quantitatively, the diagonality is characterized by a radiative oscillator strength that is smaller by a factor of two from the least of any previously published designs. At the lasing frequency of 3.9 THz, 63 mW of peak optical power was measured at 5 K, and approximately 5 mW could still be detected at 180 K.

  13. Use Of Zernike Polynomials And Interferometry In The Optical Design And Assembly Of Large Carbon-Dioxide Laser Systems

    NASA Astrophysics Data System (ADS)

    Viswanathan, V. K.

    1982-02-01

    This paper describes the need for non-raytracing schemes in the optical design and analysis of large carbon-dioxide lasers like the Gigawatt,1 Gemini, 2 and Helios3 lasers currently operational at Los Alamos, and the Antares 4 laser fusion system under construction. The scheme currently used at Los Alamos involves characterizing the various optical components with a Zernike polynomial sets obtained by the digitization6 of experimentally produced interferograms of the components. A Fast Fourier Transform code then propagates the complex amplitude and phase of the beam through the whole system and computes the optical parameters of interest. The analysis scheme is illustrated through examples of the Gigawatt, Gemini, and Helios systems. A possible way of using the Zernike polynomials in optical design problems of this type is discussed. Comparisons between the computed values and experimentally obtained results are made and it is concluded that this appears to be a valid approach. As this is a review article, some previously published results are also used where relevant.

  14. Demonstrated high performance of gas-filled rugby-shaped hohlraums on Omega

    NASA Astrophysics Data System (ADS)

    Philippe, F.; Tassin, V.; Depierreux, S.; Gauthier, P.; Masson-Laborde, P. E.; Monteil, M. C.; Seytor, P.; Villette, B.; Lasinski, B.; Park, H. S.; Ross, J. S.; Amendt, P.; Döppner, T.; Hinkel, D. E.; Wallace, R.; Williams, E.; Michel, P.; Frenje, J.; Gatu-Johnson, M.; Li, C. K.; Petrasso, R.; Glebov, V.; Sorce, C.; Stoeckl, C.; Nikroo, A.; Giraldez, E.

    2014-07-01

    A direct experimental comparison of rugby-shaped and cylindrical shaped gas-filled hohlraums on the Omega laser facility demonstrates that higher coupling and minimal backscatter can be achieved in the rugby geometry, leading to significantly enhanced implosion performance. A nearly 50% increase of x-ray drive is associated with earlier bangtime and increase of neutron production. The observed drive enhancement from rugby geometry in this study is almost twice stronger than in previously published results.

  15. Semiconductor Laser Complex Dynamics: From Optical Neurons to Optical Rogue Waves

    DTIC Science & Technology

    2017-02-11

    laser dynamics for innovative applications. The results of the project were published in 5 high- impact journal papers and were presented as invited or...stochastic phenomena and ii) to exploit the laser dynamics for innovative applications. The results of the project were published in 5 high-impact...RESULTS AND DISCUSSION The results of our research were published in 5 articles in high-impact journals in the fields of photonics and nonlinear physics

  16. Experimental Investigations of the Internal Energy of Molecules Evaporated via Laser-induced Acoustic Desorption into a Fourier-transform Ion Cyclotron Resonance Mass Spectrometer (LIAD/FT-ICR)

    PubMed Central

    Shea, Ryan C.; Petzold, Christopher J.; Liu, Ji-ang; Kenttämaa, Hilkka I.

    2008-01-01

    The internal energy of neutral gas-phase organic and biomolecules, evaporated by means of laser-induced acoustic desorption (LIAD) into a Fourier-transform ion cyclotron resonance mass spectrometer (FT-ICR), was investigated through several experimental approaches. The desorbed molecules were demonstrated not to undergo degradation during the desorption process by collecting LIAD-evaporated molecules and subjecting them to analysis by electrospray ionization/quadrupole ion trap mass spectrometry. Previously established gas-phase basicity (GB) values were remeasured for LIAD-evaporated organic molecules and biomolecules with the use of the bracketing method. No endothermic reactions were observed. The remeasured basicity values are in close agreement with the values reported in the literature. The amount of internal energy deposited during LIAD is concluded to be less than a few kcal/mol. Chemical ionization with a series of proton transfer reagents was employed to obtain a breakdown curve for a protonated dipeptide, val-pro, evaporated by LIAD. Comparison of this breakdown curve with a previously published analogous curve obtained by using substrate-assisted laser desorption (SALD) to evaporate the peptide suggests that the molecules evaporated via LIAD have less internal energy than those evaporated via SALD. PMID:17263513

  17. Matrix-free mass spectrometric imaging using laser desorption ionisation Fourier transform ion cyclotron resonance mass spectrometry.

    PubMed

    Goodwin, Richard J A; Pitt, Andrew R; Harrison, David; Weidt, Stefan K; Langridge-Smith, Pat R R; Barrett, Michael P; Logan Mackay, C

    2011-04-15

    Mass spectrometry imaging (MSI) is a powerful tool in metabolomics and proteomics for the spatial localization and identification of pharmaceuticals, metabolites, lipids, peptides and proteins in biological tissues. However, sample preparation remains a crucial variable in obtaining the most accurate distributions. Common washing steps used to remove salts, and solvent-based matrix application, allow analyte spreading to occur. Solvent-free matrix applications can reduce this risk, but increase the possibility of ionisation bias due to matrix adhesion to tissue sections. We report here the use of matrix-free MSI using laser desorption ionisation performed on a 12 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. We used unprocessed tissue with no post-processing following thaw-mounting on matrix-assisted laser desorption ionisation (MALDI) indium-tin oxide (ITO) target plates. The identification and distribution of a range of phospholipids in mouse brain and kidney sections are presented and compared with previously published MALDI time-of-flight (TOF) MSI distributions. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Laser photocoagulation around extra foveolar foci of toxoplasma retinochoroiditis: a way to decrease frequency of recurrence

    NASA Astrophysics Data System (ADS)

    Labalette, P.; Desmettre, Thomas; Mordon, Serge R.; Constantinides, G.

    1995-01-01

    Thirty four patients with retinochoroiditis initially treated with medical treatment and later treated with laser photocoagulation around the foci were retrospectively evaluated for the risk of recurrence of the eretinochoroiditis. We used a Kaplan-Meier representation to show the evolution of the number of patients without recurrence as a function of time and as the number of patients followed up decreases (rate of patients without recurrence at 1 year: 86 +/- 12.3% for 26 patients exposed; at 2 years: 75 +/- 16.4% for 20 patients exposed; at 3 years and at 4 years 70 +/- 17% for 17 patients exposed). The recurrence rates were compared to the data previously published in the literature. We failed to demonstrate the efficacy of laser photocoagulation on inactive retinochoroiditis for prevention of recurrence of ocular toxoplasmosis. However, the heterogeneity of our series, the great amount of patients lost to follow up, and the heterogeneity of the recurrence rates of the literature contribute to explain that result.

  19. Mesons from Laser-Induced Processes in Ultra-Dense Hydrogen H(0)

    PubMed Central

    2017-01-01

    Large signals of charged light mesons are observed in the laser-induced particle flux from ultra-dense hydrogen H(0) layers. The mesons are formed in such layers on metal surfaces using < 200 mJ laser pulse-energy. The time variation of the signal to metal foil collectors and the magnetic deflection to a movable pin collector are now studied. Relativistic charged particles with velocity up to 500 MeV u-1 thus 0.75 c are observed. Characteristic decay time constants for meson decay are observed, for charged and neutral kaons and also for charged pions. Magnetic deflections agree with charged pions and kaons. Theoretical predictions of the decay chains from kaons to muons in the particle beam agree with the results. Muons are detected separately by standard scintillation detectors in laser-induced processes in ultra-dense hydrogen H(0) as published previously. The muons formed do not decay appreciably within the flight distances used here. Most of the laser-ejected particle flux with MeV energy is not deflected by the magnetic fields and is thus neutral, either being neutral kaons or the ultra-dense HN(0) precursor clusters. Photons give only a minor part of the detected signals. PACS: 67.63.Gh, 14.40.-n, 79.20.Ds, 52.57.-z. PMID:28081199

  20. Engine flow visualization using a copper vapor laser

    NASA Technical Reports Server (NTRS)

    Regan, Carolyn A.; Chun, Kue S.; Schock, Harold J., Jr.

    1987-01-01

    A flow visualization system has been developed to determine the air flow within the combustion chamber of a motored, axisymmetric engine. The engine has been equipped with a transparent quartz cylinder, allowing complete optical access to the chamber. A 40-Watt copper vapor laser is used as the light source. Its beam is focused down to a sheet approximately 1 mm thick. The light plane is passed through the combustion chamber, and illuminates oil particles which were entrained in the intake air. The light scattered off of the particles is recorded by a high speed rotating prism movie camera. A movie is then made showing the air flow within the combustion chamber for an entire four-stroke engine cycle. The system is synchronized so that a pulse generated by the camera triggers the laser's thyratron. The camera is run at 5,000 frames per second; the trigger drives one laser pulse per frame. This paper describes the optics used in the flow visualization system, the synchronization circuit, and presents results obtained from the movie. This is believed to be the first published study showing a planar observation of airflow in a four-stroke piston-cylinder assembly. These flow visualization results have been used to interpret flow velocity measurements previously obtained with a laser Doppler velocimetry system.

  1. A Quantitative Analysis of the Relationship between Medicare Payment and Service Volume for Glaucoma Procedures from 2005 through 2009.

    PubMed

    Gong, Dan; Jun, Lin; Tsai, James C

    2015-05-01

    To calculate the association between Medicare payment and service volume for 6 commonly performed glaucoma procedures. Retrospective, longitudinal database study. A 100% dataset of all glaucoma procedures performed on Medicare Part B beneficiaries within the United States from 2005 to 2009. Fixed-effects regression model using Medicare Part B carrier data for all 50 states and the District of Columbia, controlling for time-invariant carrier-specific characteristics, national trends in glaucoma service volume, Medicare beneficiary population, number of ophthalmologists, and income per capita. Payment-volume elasticities, defined as the percent change in service volume per 1% change in Medicare payment, for laser trabeculoplasty (Current Procedural Terminology [CPT] code 65855), trabeculectomy without previous surgery (CPT code 66170), trabeculectomy with previous surgery (CPT code 66172), aqueous shunt to reservoir (CPT code 66180), laser iridotomy (CPT code 66761), and scleral reinforcement with graft (CPT code 67255). The payment-volume elasticity was nonsignificant for 4 of 6 procedures studied: laser trabeculoplasty (elasticity, -0.27; 95% confidence interval [CI], -1.31 to 0.77; P = 0.61), trabeculectomy without previous surgery (elasticity, -0.42; 95% CI, -0.85 to 0.01; P = 0.053), trabeculectomy with previous surgery (elasticity, -0.28; 95% CI, -0.83 to 0.28; P = 0.32), and aqueous shunt to reservoir (elasticity, -0.47; 95% CI, -3.32 to 2.37; P = 0.74). Two procedures yielded significant associations between Medicare payment and service volume. For laser iridotomy, the payment-volume elasticity was -1.06 (95% CI, -1.39 to -0.72; P < 0.001): for every 1% decrease in CPT code 66761 payment, laser iridotomy service volume increased by 1.06%. For scleral reinforcement with graft, the payment-volume elasticity was -2.92 (95% CI, -5.72 to -0.12; P = 0.041): for every 1% decrease in CPT code 67255 payment, scleral reinforcement with graft service volume increased by 2.92%. This study calculated the association between Medicare payment and service volume for 6 commonly performed glaucoma procedures and found varying magnitudes of payment-volume elasticities, suggesting that the volume response to changes in Medicare payments, if present, is not uniform across all Medicare procedures. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  2. Mg/Ca ratios of the benthic foraminifera Oridorsalis umbonatus obtained by laser ablation from core top sediments: Relationship to bottom water temperature

    NASA Astrophysics Data System (ADS)

    Rathmann, SöHnke; Hess, Silvia; Kuhnert, Henning; Mulitza, Stefan

    2004-12-01

    A laser ablation system connected to an inductively coupled plasma mass spectrometer was used to determine Mg/Ca ratios of the benthic foraminifera Oridorsalis umbonatus. A set of modern core top samples collected along a depth transect on the continental slope off Namibia (320-2300 m water depth; 2.9° to 10.4°C) was used to calibrate the Mg/Ca ratio against bottom water temperature. The resulting Mg/Ca-bottom water temperature relationship of O. umbonatus is described by the exponential equation Mg/Ca = 1.528*e0.09*BWT. The temperature sensitivity of this equation is similar to previously published calibrations based on Cibicidoides species, suggesting that the Mg/Ca ratio of O. umbonatus is a valuable proxy for thermocline and deep water temperature.

  3. Validation of Laser-Induced Fluorescent Photogrammetric Targets on Membrane Structures

    NASA Technical Reports Server (NTRS)

    Jones, Thomas W.; Dorrington, Adrian A.; Shortis, Mark R.; Hendricks, Aron R.

    2004-01-01

    The need for static and dynamic characterization of a new generation of inflatable space structures requires the advancement of classical metrology techniques. A new photogrammetric-based method for non-contact ranging and surface profiling has been developed at NASA Langley Research Center (LaRC) to support modal analyses and structural validation of this class of space structures. This full field measurement method, known as Laser-Induced Fluorescence (LIF) photogrammetry, has previously yielded promising experimental results. However, data indicating the achievable measurement precision had not been published. This paper provides experimental results that indicate the LIF-photogrammetry measurement precision for three different target types used on a reflective membrane structure. The target types were: (1) non-contact targets generated using LIF, (2) surface attached retro-reflective targets, and (3) surface attached diffuse targets. Results from both static and dynamic investigations are included.

  4. Role of ROS-mediated TGF beta activation in laser photobiomodulation

    NASA Astrophysics Data System (ADS)

    Arany, Praveen R.; Chen, Aaron Chih-Hao; Hunt, Tristan; Mooney, David J.; Hamblin, Michael

    2009-02-01

    The ability of laser light to modulate specific biological processes has been well documented but the precise mechanism mediating these photobiological interactions remains an area of intense investigation. We recently published the results of our clinical trial with 30 patients in an oral tooth-extraction wound healing model using a 904nm GaAs laser (Oralaser 1010, Oralia, Konstnaz, Germany), assessing healing parameters using routine histopathology and immunostaining (Arany et al Wound Rep Regen 2007, 15, 866). We observed a better organized healing response in laser irradiated oral tissues that correlated with an increased expression of TGF-beta1 immediately post laser irradiation. Our data suggested the source of latent TGF-beta1 might be from the degranulating platelets in the serum, an abundant source of in vivo latent TGF-beta, in the freshly wounded tissues. Further, we also demonstrated the ability of the low power near-infrared laser irradiation to activate the latent TGF-beta complexes in vitro at varying fluences from 10sec (0.1 J/cm2) to 600secs (6 J/cm2). Using serum we observed two isoforms, namely TGF-beta1 and TGF-beta3, were capable of being activated by laser irradiation using an isoform-specific ELISA and a reporter based (p3TP) assay system. We are presently pursuing the precise photomolecular mechanisms focusing on potential chromophores, wavelength and fluence parameters affecting the Latent TGF-beta activation process in serum. As ROS mediated TGF-beta activation has been previously demonstrated and we are also exploring the role of Laser generated-ROS in this activation process. In summary, we present evidence of a potential molecular mechanism for laser photobiomodulation in its ability to activate latent TGF-beta complexes.

  5. Improvements In A Laser-Speckle Surface-Strain Gauge

    NASA Technical Reports Server (NTRS)

    Lant, Christian T.

    1996-01-01

    Compact optical subsystem incorporates several improvements over optical subsystems of previous versions of laser-speckle surface-strain gauge: faster acquisition of data, faster response to transients, reduced size and weight, lower cost, and less complexity. Principle of operation described previously in "Laser System Measures Two-Dimensional Strain" (LEW-15046), and "Two-Dimensional Laser-Speckle Surface-Strain Gauge" (LEW-15337).

  6. Near-ultraviolet laser diodes for brilliant ultraviolet fluorophore excitation.

    PubMed

    Telford, William G

    2015-12-01

    Although multiple lasers are now standard equipment on most modern flow cytometers, ultraviolet (UV) lasers (325-365 nm) remain an uncommon excitation source for cytometry. Nd:YVO4 frequency-tripled diode pumped solid-state lasers emitting at 355 nm are now the primary means of providing UV excitation on multilaser flow cytometers. Although a number of UV excited fluorochromes are available for flow cytometry, the cost of solid-state UV lasers remains prohibitively high, limiting their use to all but the most sophisticated multilaser instruments. The recent introduction of the brilliant ultraviolet (BUV) series of fluorochromes for cell surface marker detection and their importance in increasing the number of simultaneous parameters for high-dimensional analysis has increased the urgency of including UV sources in cytometer designs; however, these lasers remain expensive. Near-UV laser diodes (NUVLDs), a direct diode laser source emitting in the 370-380 nm range, have been previously validated for flow cytometric analysis of most UV-excited probes, including quantum nanocrystals, the Hoechst dyes, and 4',6-diamidino-2-phenylindole. However, they remain a little-used laser source for cytometry, despite their significantly lower cost. In this study, the ability of NUVLDs to excite the BUV dyes was assessed, along with their compatibility with simultaneous brilliant violet (BV) labeling. A NUVLD emitting at 375 nm was found to excite most of the available BUV dyes at least as well as a UV 355 nm source. This slightly longer wavelength did produce some unwanted excitation of BV dyes, but at sufficiently low levels to require minimal additional compensation. NUVLDs are compact, relatively inexpensive lasers that have higher power levels than the newest generation of small 355 nm lasers. They can, therefore, make a useful, cost-effective substitute for traditional UV lasers in multicolor analysis involving the BUV and BV dyes. Published 2015 Wiley Periodicals Inc. on behalf of ISAC.

  7. Analysis of the Laser Propelled Lightcraft Vehicle

    NASA Technical Reports Server (NTRS)

    Feikema, Douglas

    2000-01-01

    Advanced propulsion research and technology require launch and space flight technologies, which can drastically reduce mission costs. Laser propulsion is a concept in which energy of a thrust producing reaction mass is supplied via beamed energy from an off-board power source. A variety of laser/beamed energy concepts were theoretically and experimentally investigated since the early 1970's. During the 1980's the Strategic Defense Initiative (SDI) research lead to the invention of the Laser Lightcraft concept. Based upon the Laser Lightcraft concept, the U.S. Air Force and NASA have jointly set out to develop technologies required for launching small payloads into Low Earth Orbit (LEO) for a cost of $1.0M or $1000/lb to $ 100/lb. The near term objectives are to demonstrate technologies and capabilities essential for a future earth to orbit launch capability. Laser propulsion offers the advantages of both high thrust and good specific impulse, I(sub sp), in excess of 1000 s. Other advantages are the simplicity and reliability of the engine because of few moving parts, simpler propellant feed system, and high specific impulse. Major limitations of this approach are the laser power available, absorption and distortion of the pulsed laser beam through the atmosphere, and coupling laser power into thrust throughout the flight envelope, The objective of this paper is to assist efforts towards optimizing the performance of the laser engine. In order to accomplish this goal (1) defocusing of the primary optic was investigated using optical ray tracing and (2), time dependent calculations were conducted of the optically induced blast wave to predict pressure and temperature in the vicinity of the cowl. Defocusing of the primary parabolic reflector causes blurring and reduction in the intensity of the laser ignition site on the cowl. However, because of the caustic effect of ray-tracing optics the laser radiation still forms a well-defined ignition line on the cowl. The blast wave calculations show reasonable agreement with previously published calculations and recent detailed CFD computations.

  8. Neurotrophic keratitis after transscleral diode laser cyclophotocoagulation.

    PubMed

    Fernández-Vega González, Á; Barraquer Compte, R I; Cárcamo Martínez, A L; Torrico Delgadillo, M; de la Paz, M F

    2016-07-01

    To study the relationship between treatment with diode laser transscleral cyclophotocoagulation and development a neurotrophic keratitis due to the damage of the sensitive corneal innervation. A study was conducted on 5 eyes of 5 patients who were treated with diode laser transscleral cyclophotocoagulation and soon developed neurotrophic ulcers. Personal characteristics of the patients were collected, as well as refraction and risk factors for corneal hypoesthesia, and the parameters of the laser used in the surgery. It was found that the 5 patients had predisposing factors of corneal hypoesthesia prior to surgery (chronic use of topical beta blockers, surgery with corneal incisions, diabetes mellitus, or corneal dystrophies); however none had developed neurotrophic keratitis until the cyclophotocoagulation was performed. It also showed that 4 of them were highly myopic, and they all were treated with high laser parameters (with an average of 2880 mW for 3s at an average surface of 275°), triggering neurotrophic ulcers between 10 and 35 days after surgery. Neurotrophic keratitis is a rare complication that can occur after diode laser transscleral cyclophotocoagulation, secondary to the damage of the long ciliary nerves. The emergence of this disorder can be triggered by the existence of previous risk factors, including high myopia, thus it is important to respect the recommended treatment parameters to prevent the development of this disorder. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  9. Long term results of diode laser cycloablation in complex glaucoma using the Zeiss Visulas II system

    PubMed Central

    Ataullah, S; Biswas, S; Artes, P H; O'Donoghue, E; Ridgway, A E A; Spencer, A F

    2002-01-01

    Aim: To investigate the safety and efficacy of the Zeiss Visulas II diode laser system in the reduction of intraocular pressure (IOP) in patients with complex glaucoma. Methods: The authors analysed the medical records of patients who underwent trans-scleral diode laser cycloablation (TDC) at the Manchester Royal Eye Hospital during a 34 month period. 55 eyes of 53 patients with complex glaucoma were followed up for a period of 12–52 months (mean 23.1 months) after initial treatment with the Zeiss Visulas II diode laser system. Results: Mean pretreatment IOP was 35.8 mm Hg (range 22–64 mm Hg). At the last examination, mean IOP was 17.3 mm Hg (range 0–40 mm Hg). After treatment, 45 eyes (82%) had an IOP between 5 and 22 mm Hg; in 46 eyes (84%) the preoperative IOP had been reduced by 30% or more. The mean number of treatment sessions was 1.7 (range 1–6). At the last follow up appointment, the mean number of glaucoma medications was reduced from 2.1 to 1.6 (p<0.05). In 10 eyes (18%), post-treatment visual acuity (VA) was worse than pretreatment VA by 2 or more lines. Conclusions: Treatment with the Zeiss Visulas II diode laser system can be safely repeated in order to achieve the target IOP. Treatment outcomes in this study were similar to those from previously published work using the Iris Medical Oculight SLx laser. PMID:11801501

  10. Computational Modeling of Semiconductor Dynamics at Femtosecond Time Scales

    NASA Technical Reports Server (NTRS)

    Agrawal, Govind P.; Goorjian, Peter M.

    1998-01-01

    The main objective of the Joint-Research Interchange NCC2-5149 was to develop computer codes for accurate simulation of femtosecond pulse propagation in semiconductor lasers and semiconductor amplifiers [I]. The code should take into account all relevant processes such as the interband and intraband carrier relaxation mechanisms and the many-body effects arising from the Coulomb interaction among charge carriers [2]. This objective was fully accomplished. We made use of a previously developed algorithm developed at NASA Ames [3]-[5]. The new algorithm was tested on several problems of practical importance. One such problem was related to the amplification of femtosecond optical pulses in semiconductors. These results were presented in several international conferences over a period of three years. With the help of a postdoctoral fellow, we also investigated the origin of instabilities that can lead to the formation of femtosecond pulses in different kinds of lasers. We analyzed the occurrence of absolute instabilities in lasers that contain a dispersive host material with third-order nonlinearities. Starting from the Maxwell-Bloch equations, we derived general multimode equations to distinguish between convective and absolute instabilities. We find that both self-phase modulation and intensity-dependent absorption can dramatically affect the absolute stability of such lasers. In particular, the self-pulsing threshold (the so-called second laser threshold) can occur at few times the first laser threshold even in good-cavity lasers for which no self-pulsing occurs in the absence of intensity-dependent absorption. These results were presented in an international conference and published in the form of two papers.

  11. Effect of neodymium:YAG laser capsulotomy on visual function in patients with posterior capsule opacification and good visual acuity.

    PubMed

    Yotsukura, Erisa; Torii, Hidemasa; Saiki, Megumi; Negishi, Kazuno; Tsubota, Kazuo

    2016-03-01

    To evaluate the effect of neodymium:YAG (Nd:YAG) laser capsulotomy on the visual function in patients with posterior capsule opacification (PCO) and good visual acuity. Keio University Hospital, Tokyo, Japan. Observational case series. Eyes were evaluated that had previous cataract surgery with a clinical diagnosis of PCO requiring Nd:YAG laser capsulotomy regardless of a good corrected distance visual acuity (CDVA) (at least 20/20). The CDVA, 10% low contrast visual acuity (LCVA), wavefront aberrations from the 3rd to 6th order, and retinal straylight were measured before and after Nd:YAG laser capsulotomy. The study included 16 eyes of 16 patients (10 men, 6 women; mean age 69.5 years ± 9.3 [SD]). The mean CDVA, LCVA, and straylight after Nd:YAG laser capsulotomy improved significantly (P < .05). The root mean square (RMS) of the 3rd Zernike coefficients (S3) and the RMS of the total higher-order aberrations (HOAs) from the 3rd to 6th order decreased significantly after capsulotomy (P < .05). The straylight correlated significantly with the total HOAs (r = 0.727, P = .002) and S3 (r = 0.748, P = .001) before capsulotomy. Subjective symptoms resolved after capsulotomy in all cases. Neodymium:YAG laser capsulotomy enabled a significant improvement in visual function even in patients with PCO with good visual acuity. Straylight measurements might be useful to determine the indications for Nd:YAG laser capsulotomy when patients report visual disturbances without decreased visual acuity. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Matrix-free mass spectrometric imaging using laser desorption ionisation Fourier transform ion cyclotron resonance mass spectrometry

    PubMed Central

    Goodwin, Richard J A; Pitt, Andrew R; Harrison, David; Weidt, Stefan K; Langridge-Smith, Pat R R; Barrett, Michael P; Logan Mackay, C

    2011-01-01

    Mass spectrometry imaging (MSI) is a powerful tool in metabolomics and proteomics for the spatial localization and identification of pharmaceuticals, metabolites, lipids, peptides and proteins in biological tissues. However, sample preparation remains a crucial variable in obtaining the most accurate distributions. Common washing steps used to remove salts, and solvent-based matrix application, allow analyte spreading to occur. Solvent-free matrix applications can reduce this risk, but increase the possibility of ionisation bias due to matrix adhesion to tissue sections. We report here the use of matrix-free MSI using laser desorption ionisation performed on a 12 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. We used unprocessed tissue with no post-processing following thaw-mounting on matrix-assisted laser desorption ionisation (MALDI) indium-tin oxide (ITO) target plates. The identification and distribution of a range of phospholipids in mouse brain and kidney sections are presented and compared with previously published MALDI time-of-flight (TOF) MSI distributions. Copyright © 2011 John Wiley & Sons, Ltd. PMID:21416534

  13. OH PLIF Visualization of the UVa Supersonic Combustion Experiment: Configuration C

    NASA Technical Reports Server (NTRS)

    McRae, Colin D.; Johansen, Craig T.; Danehy, Paul M.; Gallo, Emanuela C. A.; Cantu, Luca M. L.; Magnotti, Gaetano; Cutler, Andrew D.; Rockwell, Robert D., Jr.; Goyne, Christopher P.; McDnaiel, James C.

    2013-01-01

    Non-intrusive hydroxyl radical (OH) planar laser-induced fluorescence (PLIF) measurements were obtained in configuration C of the University of Virginia supersonic combustion experiment. The combustion of hydrogen fuel injected through an unswept compression ramp into a supersonic cross-flow was imaged over a range of streamwise positions. Images were corrected for optical distortion, variations in the laser sheet profile, and different camera views. Results indicate an effect of fuel equivalence ratio on combustion zone shape and local turbulence length scale. The streamwise location of the reaction zone relative to the fuel injector was also found to be sensitive to the fuel equivalence ratio. The flow boundary conditions in the combustor section, which are sensitive to the fuel flow rate, are believed to have caused this effect. A combination of laser absorption and radiative trapping effects are proposed to have caused asymmetry observed in the images. The results complement previously published OH PLIF data obtained for configuration A along with other non-intrusive measurements to form a database for computational fluid dynamics (CFD) model validation.

  14. Confocal laser induced fluorescence with comparable spatial localization to the conventional method

    NASA Astrophysics Data System (ADS)

    Thompson, Derek S.; Henriquez, Miguel F.; Scime, Earl E.; Good, Timothy N.

    2017-10-01

    We present measurements of ion velocity distributions obtained by laser induced fluorescence (LIF) using a single viewport in an argon plasma. A patent pending design, which we refer to as the confocal fluorescence telescope, combines large objective lenses with a large central obscuration and a spatial filter to achieve high spatial localization along the laser injection direction. Models of the injection and collection optics of the two assemblies are used to provide a theoretical estimate of the spatial localization of the confocal arrangement, which is taken to be the full width at half maximum of the spatial optical response. The new design achieves approximately 1.4 mm localization at a focal length of 148.7 mm, improving on previously published designs by an order of magnitude and approaching the localization achieved by the conventional method. The confocal method, however, does so without requiring a pair of separated, perpendicular optical paths. The confocal technique therefore eases the two window access requirement of the conventional method, extending the application of LIF to experiments where conventional LIF measurements have been impossible or difficult, or where multiple viewports are scarce.

  15. Gravity model improvement using GEOS-3 (GEM 9 and 10)

    NASA Technical Reports Server (NTRS)

    Lerch, F. J.; Klosko, S. M.; Laubscher, R. E.; Wagner, C. A.

    1977-01-01

    The use of collocation permitted GEM 9 to be a larger field than previous derived satellite models, GEM 9 having harmonics complete to 20 x 20 with selected higher degree terms. The satellite data set has approximately 840,000 observations, of which 200,000 are laser ranges taken on 9 satellites equipped with retroreflectors. GEM 10 is complete to 22 x 22 with selected higher degree terms out to degree and order 30 amounting to a total of 592 coefficients. Comparisons with surface gravity and altimeter data indicate a substantial improvement in GEM 9 over previous satellite solutions; GEM 9 is in even closer agreement with surface data than the previously published GEM 6 solution which contained surface gravity. In particular the free air gravity anomalies calculated from GEM 9 and a surface gravity solution are in excellent agreement for the high degree terms.

  16. Outcomes of photorefractive keratectomy following laser in situ keratomileusis: a cohort study.

    PubMed

    Iovieno, Alfonso; Teichman, Joshua C; Low, Stephanie; Yeung, Sonia N; Eve Lègarè, Marie; Lichtinger, Alejandro D; Slomovic, Allan R; Rootman, David S

    2016-12-01

    To analyze the outcomes of photorefractive keratectomy (PRK) on residual myopia and hyperopia post-laser in situ keratomileusis (LASIK) and to compare these results with PRK on eyes without previous laser refractive surgery. Retrospective comparative cohort study. Patients undergoing PRK between 2006 and 2010 were reviewed. Patients were divided into 4 groups, myopic or hyperopic PRK post-LASIK (mPRK-PL and hPRK-PL, respectively) and myopic or hyperopic PRK on corneas without previous laser refractive surgery (mPRK and hPRK, respectively). Uncorrected and corrected distance visual acuity, mean refractive spherical equivalent (MRSE), and mean keratometry and aberrations (total, higher order [HOA], coma, trefoil, and spherical aberration) were recorded at months 3 and 6 postoperatively, as were complications and attempted versus achieved MRSE. Thirty-three eyes of 25 patients who underwent PRK post-LASIK (21 eyes of 14 patients for hPRK-PL and 12 eyes of 11 patients for mPRK-PL) and 35 eyes of 21 patients who underwent PRK on virgin eyes (11 eyes of 8 patients for hPRK and 24 eyes of 13 patients for mPRK) were included in the study. The only significant differences in outcomes were found to be HOA at 3 months for hPRK-PL as compared with both hPRK and mPRK. Achieved MRSE was significantly different from expected MRSE for hPRK-PL at 3 months postoperatively. No haze- or flap-related complications were observed. Outcomes of PRK were not different in myopic and hyperopic corrections post-LASIK by 6 months or when compared with PRK in virgin eyes. HOA may render hPRK-PL results less predictable early in the postoperative period. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  17. Leptons from decay of mesons in the laser-induced particle pulse from ultra-dense protium p(0)

    NASA Astrophysics Data System (ADS)

    Holmlid, Leif

    2016-10-01

    Kaons and pions are observed by their characteristic decay times of 12, 52 and 26 ns after impact of relatively weak ns-long laser pulses on ultra-dense hydrogen H(0), as reported previously. The signal using an ultra-dense protium p(0) generator with natural hydrogen is now studied. Deflection in a weak magnetic field or penetration through metal foils cannot distinguish between the types of decaying mesons. The signals observed are thus not caused by the decaying mesons themselves, but by the fast particles often at >50MeV u-1 formed in their decay. The fast particles are concluded to be mainly muons from their relatively small magnetic deflection and strong penetration. This is further supported by published studies on the direct observation of the beta decay of muons in scintillators and solid converters using the same type of p(0) generator.

  18. Nuclear isomer suitable for gamma ray laser

    NASA Technical Reports Server (NTRS)

    Jha, S.

    1979-01-01

    The operation of gamma ray lasers (gasers) are studied. It is assumed that the nuclear isomers mentioned in previously published papers have inherent limitations. It is further assumed that the judicious use of Bormann effect or the application of the total external reflection of low energy gamma radiation at grazing angle of incidence may permit the use of a gaser crystal sufficiently long to achieve observable stimulated emission. It is suggested that a long lived 0(+) isomer decaying by low energy gamma ray emission to a short lived 2(+) excited nuclear state would be an attractive gaser candidate. It is also suggested that the nuclear isomer be incorporated in a matrix of refractory material having an electrostatic field gradient whose principal axis lies along the length of the medium. This results in the preferential transmission of electric quadrupole radiation along the length of the medium.

  19. Terahertz laser spectroscopy of the water dimer intermolecular vibrations. I. (D2O)2

    NASA Astrophysics Data System (ADS)

    Braly, L. B.; Cruzan, J. D.; Liu, K.; Fellers, R. S.; Saykally, R. J.

    2000-06-01

    Terahertz laser VRT spectra of the water dimer consisting of 731 transitions measured with an average precision of 2 MHz and involving four (D2O)2 intermolecular vibrations (one previously published) have been measured between 65 and 104 cm-1. The precisely determined energy level patterns differ both qualitatively and quantitatively from the predictions of several dimer potentials tested, and reveal an ordering of the intermolecular vibrations which differs dramatically from that predicted by standard normal mode analysis. Strong coupling is indicated between the low barrier tunneling motions and the intermolecular vibrations as well as among different vibrations. Particularly, the 83 cm-1 (acceptor wag) and 90 cm-1 (D2O)2 (acceptor twist) vibrations interact through a Coriolis perturbation. These spectra provide the basis for our recent determination of the water pair potential. The corresponding data set for (H2O)2 is presented in an accompanying paper.

  20. EDITORIAL: Letter from the Editor Letter from the Editor

    NASA Astrophysics Data System (ADS)

    Pashinin, Pavel P.

    2013-01-01

    Dear readers, contributors, and members of the world laser physics community. It is a great honour for us to introduce to you our new publishing partner, IOP Publishing, a subsidiary of the Institute of Physics, United Kingdom. IOP Publishing is a world renowned authority in producing journals, magazines, websites and services that enable researchers and research organizations to present their work to a world-wide audience. Laser Physics, the first English-language scientific journal in Russia, was founded in 1990 on the initiative of Alexander M Prokhorov, a pioneer and leader in laser physics research. Professor Prokhorov served as the first Editor-in-Chief of the journal until 2002. We are proud that it is our 23rd year of publishing Laser Physics and our 10th year of publishing Laser Physics Letters. We would like to honour the memory of our friend, late Professor Igor Yevseyev, whose enthusiasm and unwavering dedication to our journals contributed most significantly to their success. It was initially his idea in 2011 to approach IOP with a partnership proposal. We deeply regret that he is no longer with us as we enter this productive alliance. Now, in partnership with IOP, we are turning a new page in providing world-wide access to the cutting-edge research results in our journals, serving our well established global audience. We see new horizons opening for our journals for years to come and hope that our readers share our enthusiasm and aspirations. Please accept our best wishes for all your new scientific endeavors in the exciting field of laser physics.

  1. Near infrared diffuse reflection and laser-induced fluorescence spectroscopy for myocardial tissue characterisation

    NASA Astrophysics Data System (ADS)

    Nilsson, A. M. K.; Heinrich, D.; Olajos, J.; Andersson-Engels, S.

    1997-10-01

    In order to evaluate the potential of cardiovascular tissue characterisation using near-infrared (NIR) spectroscopy, spectra in a previously unexplored wavelength region 0.8-2.3 μm were recorded from various pig heart tissue samples in vitro: normal myocardium (with and without endo/epicardium), aorta, fatty and fibrous heart tissue. The spectra were analysed with principal component analysis (PCA), revealing several spectroscopically characteristic features enabling tissue classification. Several of the identified spectral features could be attributed to specific tissue constituents by comparing the tissue signals with spectra obtained from water, elastin, collagen and cholesterol as well as with published data. The results obtained with the NIR spectroscopy technique in terms of its potential to classify different tissue types were compared with those from laser-induced fluorescence (LIF) using 337 nm excitation. LIF and NIR spectroscopy can in combination with PCA be used to discriminate between all previously mentioned tissue groups, apart from fatty versus fibrous tissue (LIF) and aorta versus fibrous tissue (NIR), respectively. The NIR analysis was improved by focusing the PCA to the wavelength segment 2.0-2.3 μm, resulting in successful spectral characterisation of all cardiovascular tissue groups.

  2. Synthesis of Ag-doped TiO2 nanoparticles by combining laser decomposition of titanium isopropoxide and ablation of Ag for dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Al-Kamal, Ahmed Kamal

    Nanostructured powders of TiO2 and Ag-doped TiO2 are synthesized by a novel pulsed-laser process that combines laser ablation of a silver (Ag) disc with laser decomposition of a titanium tetra-isopropoxide (TTIP) solution. Nanoparticles are formed by rapid condensation of vaporized species in the plasma plume generated by the high power laser, resulting in the formation of rapidly quenched Ag-doped TiO2 nanoparticles that have far-from-equilibrium or metastable structures. The uniqueness of the new ablation process is that it is a one-step process, in contrast to the two-step process developed by previous researchers in the field. Moreover, its ability to synthesize an extended-solid solution phase of Ag in TiO 2 may also be unique. The present work implies that other oxide phases, such as Al2O3, MgO and MgAl2O4, can be doped with normally insoluble metals, such as Pt and Ir, thus opening new opportunities for catalytic applications. Again, there is the prospect of being able to synthesize nanopowders of diamond, c-BN, and mixtures thereof, which are of interest for applications in machine tools, rock-drill bits, and lightweight armor. A wet-chemistry method is also investigated, which has much in common with that adopted by previous workers in the field. However, photo-voltaic properties do not measure up to expectations based on published data. A possible explanation is that the selected Ag concentrations are too high, so that recombination of holes and electrons occurs via a quantum-tunneling mechanism reduces photo-activity. Future work, therefore, will investigate lower concentrations of Ag dopant in TiO2, while also examining the effects of metastable states, including extended solid solution, amorphous, and semi-crystalline structures.

  3. Visible lesion thresholds and model predictions for Q-switched 1318-nm and 1540-nm laser exposures to porcine skin

    NASA Astrophysics Data System (ADS)

    Zohner, Justin J.; Schuster, Kurt J.; Chavey, Lucas J.; Stolarski, David J.; Kumru, Semih S.; Rockwell, Benjamin A.; Thomas, Robert J.; Cain, Clarence P.

    2006-02-01

    Skin damage thresholds were measured and compared with theoretical predictions using a skin thermal model for near-IR laser pulses at 1318 nm and 1540 nm. For the 1318-nm data, a Q-switched, 50-ns pulse with a spot size of 5 mm was applied to porcine skin and the damage thresholds were determined at 1 hour and 24 hours postexposure using Probit analysis. The same analysis was conducted for a Q-switched, 30-ns pulse at 1540 nm with a spot size of 5 mm. The Yucatan mini-pig was used as the skin model for human skin due to its similarity to pigmented human skin. The ED 50 for these skin exposures at 24 hours postexposure was 10.5 J/cm2 for the 1318-nm exposures, and 6.1 J/cm2 for the 1540-nm exposures. These results were compared to thermal model predictions. We show that the thermal model fails to account for the ED 50 values observed. A brief discussion of the possible causes of this discrepancy is presented. These thresholds are also compared with previously published skin minimum visible lesion (MVL) thresholds and with the ANSI Standard's MPE for 1318-nm lasers at 50 ns and 1540-nm lasers at 30 ns.

  4. Laser direct writing of complex radially varying single-mode polymer waveguide structures

    NASA Astrophysics Data System (ADS)

    Kruse, Kevin; Peng, Jie; Middlebrook, Christopher T.

    2015-07-01

    Increasing board-to-board and chip-to-chip computational data rates beyond 12.5 Gbs will require the use of single-mode polymer waveguides (WGs) that have high bandwidths and are able to be wavelength division multiplexed. Laser direct writing (LDW) of polymer WGs provides a scalable and reconfigurable maskless procedure compared to common photolithography fabrication. LDW of straights and radial curves are readily achieved using predefined drive commands of the two-axis direct drive linear stage system. Using the laser direct write process for advanced WG structures requires stage-drive programming techniques that account for specified polymer material exposure durations. Creating advanced structures such as WG S-bends into single-mode polymer WG builds provides designers with the ability to affect pitch control, optical coupling, and reduce footprint requirements. Fabrication of single-mode polymer WG segmented radial arcs is achieved through a smooth radial arc user-programmed defined mathematical algorithm. Cosine and raised-sine S-bends are realized through a segmentation method where the optimal incremental step length and bend dimensions are controlled to achieve minimal structure loss. Laser direct written S-bends are compared with previously published photolithographic S-bend results using theoretical bend loss models. Fabrication results show that LDW is a viable method in the fabrication of advanced polymer WG structures.

  5. Laser Propulsion Standardization Issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scharring, Stefan; Eckel, Hans-Albert; Roeser, Hans-Peter

    It is a relevant issue in the research on laser propulsion that experimental results are treated seriously and that meaningful scientific comparison is possible between groups using different equipment and measurement techniques. However, critical aspects of experimental measurements are sparsely addressed in the literature. In addition, few studies so far have the benefit of independent confirmation by other laser propulsion groups. In this paper, we recommend several approaches towards standardization of published laser propulsion experiments. Such standards are particularly important for the measurement of laser ablation pulse energy, laser spot area, imparted impulse or thrust, and mass removal during ablation.more » Related examples are presented from experiences of an actual scientific cooperation between NU and DLR. On the basis of a given standardization, researchers may better understand and contribute their findings more clearly in the future, and compare those findings confidently with those already published in the laser propulsion literature. Relevant ISO standards are analyzed, and revised formats are recommended for application to laser propulsion studies.« less

  6. Dye-Assisted Laser Skin Closure with Pulsed Radiation: An In Vitro Study of Weld Strength and Thermal Damage

    NASA Astrophysics Data System (ADS)

    Fried, Nathaniel M.; Walsh, Joseph T.

    1998-10-01

    Previous laser skin welding studies have used continuous wave delivery of radiation. However, heat diffusion during irradiation prevents strong welds from being achieved without creating large zones of thermal damage. Previously published results indicate that a thermal damage zone in skin greater than 200 micrometers may prevent normal wound healing. We proposed that both strong welds and minimal thermal damage can be achieved by introducing a dye and delivering the radiation in a series of sufficiently short pulses. Two-cm-long incisions were made in guinea pig skin, in vitro. India ink and egg white (albumin) were applied to the wound edges to enhance radiation absorption and to close the wound, respectively. Continuous wave (cw), 1.06 micrometers , Nd:yttrium-aluminum-garnet laser radiation was scanned over the weld producing approximately 100 ms pulses. The cooling time between scans and the number of scans was varied. The thermal damage zone at the weld edges was measured using a transmission polarizing light microscope. The tensile strength of the welds was measured using a tensiometer. For pulsed welding and long cooling times between pulses (8 s), weld strengths of 2.4 +/- 0.9 kg/cm2 were measured, and lateral thermal damage at the epidermis was limited to 500 +/- 150 micrometers . With cw welding, comparable weld strengths produced 2700 +/- 300 micrometers of lateral thermal damage. The cw weld strengths were only 0.6 +/- 0.3 kg/cm2 for thermal damage zones comparable to pulsed welding.

  7. US-guided application of Nd:YAG laser in porcine pancreatic tissue: an ex vivo study and numerical simulation.

    PubMed

    Di Matteo, Francesco; Martino, Margareth; Rea, Roberta; Pandolfi, Monica; Panzera, Francesco; Stigliano, Egidio; Schena, Emiliano; Saccomandi, Paola; Silvestri, Sergio; Pacella, Claudio Maurizio; Breschi, Luca; Perrone, Giuseppe; Coppola, Roberto; Costamagna, Guido

    2013-11-01

    Laser ablation (LA) with a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser is a minimally invasive approach able to achieve a high rate of complete tissue necrosis. In a previous study we described the feasibility of EUS-guided Nd:YAG pancreas LA performed in vivo in a porcine model. To establish the best laser setting of Nd:YAG lasers for pancreatic tissue ablation. A secondary aim was to investigate the prediction capability of a mathematical model on ablation volume. Ex vivo animal study. Hospital animal laboratory. Explanted pancreatic glands from 60 healthy farm pigs. Laser output powers (OP) of 1.5, 3, 6, 10, 15, and 20 W were supplied. Ten trials for each OP were performed under US guidance on ex vivo healthy porcine pancreatic tissue. Ablation volume (Va) and central carbonization volume (Vc) were measured on histologic specimens as the sum of the lesion areas multiplied by the thickness of each slide. The theoretical model of the laser-tissue interaction was based on the Pennes equation. A circumscribed ablation zone was observed in all histologic specimens. Va values grow with the increase of the OP up to 10 W and reach a plateau between 10 and 20 W. The trend of Vc values rises constantly until 20 W. The theoretical model shows a good agreement with experimental Va and Vc for OP between 1.5 and 10 W. Ex vivo study. Volumes recorded suggest that the best laser OP could be the lowest one to obtain similar Va with smaller Vc in order to avoid the risk of thermal injury to the surrounding tissue. The good agreement between the two models demonstrates the prediction capability of the theoretical model on laser-induced ablation volume in an ex vivo animal model and supports its potential use for estimating the ablation size at different laser OPs. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  8. Biostimulative effects of 809 nm diode laser on cutaneous skin wounds

    NASA Astrophysics Data System (ADS)

    Solmaz, Hakan; Gülsoy, Murat; Ülgen, Yekta

    2015-03-01

    The use of low-level laser therapy (LLLT) for therapeutic purposes in medicine has become widespread recently. There are many studies in literature supporting the idea of therapeutic effects of laser irradiation on biological tissues. The aim of this study is to investigate the biostimulative effect of 809nm infrared laser irradiation on the healing process of cutaneous incisional skin wounds. 3-4 months old male Wistar Albino rats weighing 300 to 350 gr were used throughout this study. Lowlevel laser therapy was applied through local irradiation of 809nm infrared laser on open skin incisional wounds of 1 cm length. Each animal had six identical incisions on their right and left dorsal region symmetrical to each other. The wounds were separated into three groups of control, 1 J/cm2 and 3 J/cm2 of laser irradiation. Two of these six wounds were kept as control group and did not receive any laser application. Rest of the incisions was irradiated with continuous diode laser of 809nm in wavelength and 20mW power output. Two of them were subjected to laser irradiation of 1 J/cm2 and the other two were subjected to laser light with energy density of 3 J/cm2. Biostimulation effects of irradiation were studied by means of tensile strength tests and histological examinations. Wounded skin samples were morphologically examined and removed for mechanical and histological examinations at days 3, 5 and 7 following the laser applications. Three of the six fragments of skin incisions including a portion of peripheral healthy tissue from each animal were subjected to mechanical tests by means of a universal tensile test machine, whereas the other three samples were embedded in paraffin and stained with hematoxylin and eosin for histological examinations. The findings of the study show that tissue repair following laser irradiation of 809nm has been accelerated in terms of tissue morphology, strength and cellular content. These results seem to be consistent with the results of many researches previously published in literature and support the idea that LLLT has therapeutic effect on wound healing process.

  9. Guiding flying-spot laser transepithelial phototherapeutic keratectomy with optical coherence tomography.

    PubMed

    Li, Yan; Yokogawa, Hideaki; Tang, Maolong; Chamberlain, Winston; Zhang, Xinbo; Huang, David

    2017-04-01

    To analyze transepithelial phototherapeutic keratectomy (PTK) results using optical coherence tomography (OCT) and develop a model to guide the laser dioptric and depth settings. Casey Eye Institute, Portland, Oregon, USA. Prospective nonrandomized case series. Patients with superficial corneal opacities and irregularities had transepithelial PTK with a flying-spot excimer laser by combining wide-zone myopic and hyperopic astigmatic ablations. Optical coherence tomography was used to calculate corneal epithelial lenticular masking effects, guide refractive laser settings, and measure opacity removal. The laser ablation efficiency and the refractive outcome were investigated using multivariate linear regression models. Twenty-six eyes of 20 patients received PTK to remove opacities and irregular astigmatism due to scar, dystrophy, radial keratotomy, or previous corneal surgeries. The uncorrected distance visual acuity and corrected distance visual acuity were significantly improved (P < .01) by 3.7 Snellen lines and 2.0 Snellen lines, respectively, to a mean of 20/41.2 and 20/22.0, respectively. Achieved laser ablation depths were 31.3% (myopic ablation) and 63.0% (hyperopic ablation) deeper than the manufacturer's nomogram. The spherical equivalent of the corneal epithelial lenticular masking effect was 0.73 diopter ± 0.61 (SD). The refractive outcome highly correlated to the laser settings and epithelial lenticular masking effect (Pearson R = 0.96, P < .01). The ablation rate of granular dystrophy opacities appeared to be slower. Smoothing ablation under masking fluid was needed to prevent focal steep islands in these cases. The OCT-measured ablation depth efficiency could guide opacity removal. The corneal epithelial lenticular masking effect could refine the spherical refractive nomogram to achieve a better refractive outcome after transepithelial ablation. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. The Potential Role of Drexon LaserCards in Optical Publishing.

    ERIC Educational Resources Information Center

    Schwerin, Julie B.

    1985-01-01

    Describes Drexon LaserCard (credit card size format holding two megabytes of digital data that can be recorded at factory or by information distributors) as a viable option to rotating optical media for distribution of computer software, technical manuals, periodicals, and other document applications, and projects its future in optical publishing.…

  11. Comment on "Hydrogen Balmer beta: The separation between line peaks for plasma electron density diagnostics and self-absorption test"

    NASA Astrophysics Data System (ADS)

    Gautam, Ghaneshwar; Surmick, David M.; Parigger, Christian G.

    2015-07-01

    In this letter, we present a brief comment regarding the recently published paper by Ivković et al., J Quant Spectrosc Radiat Transf 2015;154:1-8. Reference is made to previous experimental results to indicate that self absorption must have occurred; however, when carefully considering error propagation, both widths and peak-separation predict electron densities within the error margins. Yet the diagnosis method and the presented details on the use of the hydrogen beta peak separation are viewed as a welcomed contribution in studies of laser-induced plasma.

  12. Possibilities of Laser Processing of Paper Materials

    NASA Astrophysics Data System (ADS)

    Stepanov, Alexander; Saukkonen, Esa; Piili, Heidi

    Nowadays, lasers are applied in many industrial processes: the most developed technologies include such processes as laser welding, hybrid welding, laser cutting of steel, etc. In addition to laser processing of metallic materials, there are also many industrial applications of laser processing of non-metallic materials, like laser welding of polymers, laser marking of glass and laser cutting of wood-based materials. It is commonly known that laser beam is suitable for cutting of paper materials as well as all natural wood-fiber based materials. This study reveals the potential and gives overview of laser application in processing of paper materials. In 1990's laser technology increased its volume in papermaking industry; lasers at paper industry gained acceptance for different perforating and scoring applications. Nowadays, with reduction in the cost of equipment and development of laser technology (especially development of CO2 technology), laser processing of paper material has started to become more widely used and more efficient. However, there exists quite little published research results and reviews about laser processing of paper materials. In addition, forest industry products with pulp and paper products in particular are among major contributors for the Finnish economy with 20% share of total exports in the year 2013. This has been the standpoint of view and motivation for writing this literature review article: when there exists more published research work, knowledge of laser technology can be increased to apply it for processing of paper materials.

  13. Matrix Optical Absorption in UV-MALDI MS

    NASA Astrophysics Data System (ADS)

    Robinson, Kenneth N.; Steven, Rory T.; Bunch, Josephine

    2018-03-01

    In ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI MS) matrix compound optical absorption governs the uptake of laser energy, which in turn has a strong influence on experimental results. Despite this, quantitative absorption measurements are lacking for most matrix compounds. Furthermore, despite the use of UV-MALDI MS to detect a vast range of compounds, investigations into the effects of laser energy have been primarily restricted to single classes of analytes. We report the absolute solid state absorption spectra of the matrix compounds α-cyano-4-hydroxycinnamic acid (CHCA), para-nitroaniline (PNA), 2-mercaptobenzothiazole (MBT), 2,5-dihydroxybenzoic acid (2,5-DHB), and 2,4,6-trihydroxyacetophenone (THAP). The desorption/ionization characteristics of these matrix compounds with respect to laser fluence was investigated using mixed systems of matrix with either angiotensin II, PC(34:1) lipid standard, or haloperidol, acting as representatives for typical classes of analyte encountered in UV-MALDI MS. The first absolute solid phase spectra for PNA, MBT, and THAP are reported; additionally, inconsistencies between previously published spectra for CHCA are resolved. In light of these findings, suggestions are made for experimental optimization with regards to matrix and laser wavelength selection. The relationship between matrix optical cross-section and wavelength-dependant threshold fluence, fluence of maximum ion yield, and R, a new descriptor for the change in ion intensity with fluence, are described. A matrix cross-section of 1.3 × 10-17 cm-2 was identified as a potential minimum for desorption/ionization of analytes.

  14. Matrix Optical Absorption in UV-MALDI MS.

    PubMed

    Robinson, Kenneth N; Steven, Rory T; Bunch, Josephine

    2018-03-01

    In ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI MS) matrix compound optical absorption governs the uptake of laser energy, which in turn has a strong influence on experimental results. Despite this, quantitative absorption measurements are lacking for most matrix compounds. Furthermore, despite the use of UV-MALDI MS to detect a vast range of compounds, investigations into the effects of laser energy have been primarily restricted to single classes of analytes. We report the absolute solid state absorption spectra of the matrix compounds α-cyano-4-hydroxycinnamic acid (CHCA), para-nitroaniline (PNA), 2-mercaptobenzothiazole (MBT), 2,5-dihydroxybenzoic acid (2,5-DHB), and 2,4,6-trihydroxyacetophenone (THAP). The desorption/ionization characteristics of these matrix compounds with respect to laser fluence was investigated using mixed systems of matrix with either angiotensin II, PC(34:1) lipid standard, or haloperidol, acting as representatives for typical classes of analyte encountered in UV-MALDI MS. The first absolute solid phase spectra for PNA, MBT, and THAP are reported; additionally, inconsistencies between previously published spectra for CHCA are resolved. In light of these findings, suggestions are made for experimental optimization with regards to matrix and laser wavelength selection. The relationship between matrix optical cross-section and wavelength-dependant threshold fluence, fluence of maximum ion yield, and R, a new descriptor for the change in ion intensity with fluence, are described. A matrix cross-section of 1.3 × 10 -17 cm -2 was identified as a potential minimum for desorption/ionization of analytes. Graphical Abstract ᅟ.

  15. Nonablative laser resurfacing: state of the art 2002.

    PubMed

    Pozner, Jason N; Goldberg, David J

    2002-09-01

    The reader is presumed to have a basic understanding of the use of lasers in plastic surgery and laser physics. After reading this article, the participant should be able to: Physicians may earn 1 hour of Category 1 CME credit by successfully completing the examination on the basis of material covered in this article. The examination begins on page 435. Nonablative resurfacing, also referred to as subsurface or dermal remodeling, is a recently introduced technology for restoring damaged collagen without injuring or removing the overlying epidermis. To date there have been no published comparisons or reviews of these laser systems. The authors review the mechanisms of action of currently available nonablative laser technologies and published data on their performance. Literature concerning nonablative laser technology published between 2000 and 2002 was reviewed by use of Medline searches. Data on technical specifications were obtained from the manufacturers. Significant improvement in skin elasticity and photodamage with few or no complications was noted after treatment with most of the systems reviewed. However, the results were generally more subtle than those achieved with ablative lasers. Nonablative technology is currently at the forefront of skin rejuvenation. Data on long-term results must await several more years of accumulated clinical treatment. Improvement in skin quality, tone, and texture can be expected, but patients and physicians who expect nonablative laser treatment results to be similar to those achieved by ablative techniques may be disappointed. (Aesthetic Surg J 2002;22:427-434.).

  16. Femtosecond Laser Flap Creation for Laser In Situ Keratomileusis in the Setting of Previous Radial Keratotomy.

    PubMed

    Rush, Sloan W; Rush, Ryan B

    2015-01-01

    The aim of the study was to report the outcomes of laser in situ keratomileusis (LASIK) in subjects with previous radial keratotomy (RK) using a novel femtosecond laser setting on a proprietary femtosecond laser platform. This was a retrospective, consecutive chart review of patients at a single private practice institution. The medical records of 16 eyes of 8 subjects who underwent femtosecond-assisted LASIK for consecutive hyperopia after RK were retrospectively reviewed. The preoperative characteristics, intraoperative details, and postoperative outcomes were analyzed. All 16 eyes had successful femtosecond laser flap creation without significant intraoperative or postoperative complications. Uncorrected visual acuity significantly improved postoperatively (P = 0.0142) and remained stable through the final follow-up interval at 9 to 12 months postoperatively. None of the subjects lost any lines of best spectacle-corrected visual acuity in the postoperative period. The novel femtosecond laser technique described in this study can provide a safe and effective method for patients undergoing LASIK after previous RK. Future investigations are required to further validate the findings reported in this study.

  17. Single and low order mode interrogation of a multimode sapphire fiber Bragg grating sensor with tapered fibers

    NASA Astrophysics Data System (ADS)

    Grobnic, Dan; Mihailov, Stephen J.; Ding, H.; Bilodeau, F.; Smelser, Christopher W.

    2005-05-01

    Multimode sapphire fiber Bragg gratings (SFBG) made with an IR femtosecond laser and a phase mask were probed using tapered single mode fibers of different taper diameters producing single and low order mode reflection/transmission responses. A configuration made of an input single mode tapered fiber and multimode silica fiber used for output coupling was also tested and has delivered a filtered multimode transmission spectrum. The tapered coupling improved the spectral resolution of the SFBG as compared to its multimode responses previously reported. Such improvements facilitate the utilization of the SFBG as a high temperature sensor. Wavelength shifts of the single mode response were monitored as a function of temperature up to 1500 °C and were consistent with the measurement obtained from the multimode response published previously.

  18. Femtosecond-assisted laser in situ keratomileusis for consecutive hyperopia after radial keratotomy.

    PubMed

    Leccisotti, Antonio; Fields, Stefania V

    2015-08-01

    To evaluate femtosecond-assisted laser in situ keratomileusis (LASIK) for the treatment of hyperopic shift after radial keratotomy (RK). Private practice, Siena, Italy. Prospective case series. Eyes with a spherical equivalent (SE) of +1.0 diopters (D) to +4.0 D after RK with 6 or 8 incisions had LASIK. The flap (nominal thickness 130 μm) was created with a femtosecond laser (LDV Z2); the refractive ablation was performed with an excimer laser (217P). The flap was dissected in a centrifugal fashion along previous RK cuts. Eighteen eyes of 10 patients were treated. Preoperatively, the mean defocus equivalent was 3.13 diopters (D) ± 0.71 (SD); the corrected distance visual acuity (CDVA) was 0.09 ± 0.06 logMAR. At 9 months, the mean defocus equivalent was 0.51 ± 0.47 D (P < .05), with 13 eyes (72%) having 0.50 D or less of defocus equivalent and 16 eyes (89%) having 1.0 D or less of defocus equivalent. The mean CDVA was 0.04 ± 0.06 logMAR (P < .05). No lines of logMAR CDVA were lost. The mean uncorrected distance visual acuity was 0.11 ± 0.10 logMAR. The safety index was 1.11; the efficacy index was 0.97. No retreatments were performed. Flap complications were limited to an RK incision opening larger than 2 mm in 3 eyes and 1 case of a small, self-limiting epithelial ingrowth. Laser in situ keratomileusis with a low-energy femtosecond laser was a safe and effective approach to treat post-RK hyperopia, causing no relevant inflammation. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Laser-material interaction during atom probe tomography of oxides with embedded metal nanoparticles

    DOE PAGES

    Shinde, D.; Arnoldi, L.; Devaraj, A.; ...

    2016-10-28

    Oxide-supported metal nano-particles are of great interest in catalysis but also in the development of new large-spectrum-absorption materials. The design of such nano materials requires three-dimensional characterization with a high spatial resolution and elemental selectivity. The laser assisted Atom Probe Tomography (La-APT) presents both these capacities if an accurate understanding of laser-material interaction is developed. In this paper, we focus on the fundamental physics of field evaporation as a function of sample geometry, laser power, and DC electric field for Au nanoparticles embedded in MgO. By understanding the laser-material interaction through experiments and a theoretical model of heat diffusion insidemore » the sample after the interaction with laser pulse, we point out the physical origin of the noise and determine the conditions to reduce it by more than one order of magnitude, improving the sensitivity of the La-APT for metal-dielectric composites. Published by AIP Publishing.« less

  20. An overview of clinical and experimental treatment modalities for port wine stains.

    PubMed

    Chen, Jennifer K; Ghasri, Pedram; Aguilar, Guillermo; van Drooge, Anne Margreet; Wolkerstorfer, Albert; Kelly, Kristen M; Heger, Michal

    2012-08-01

    Port wine stains (PWS) are the most common vascular malformation of the skin, occurring in 0.3% to 0.5% of the population. Noninvasive laser irradiation with flashlamp-pumped pulsed dye lasers (selective photothermolysis) currently comprises the gold standard treatment of PWS; however, the majority of PWS fail to clear completely after selective photothermolysis. In this review, the clinically used PWS treatment modalities (pulsed dye lasers, alexandrite lasers, neodymium:yttrium-aluminum-garnet lasers, and intense pulsed light) and techniques (combination approaches, multiple passes, and epidermal cooling) are discussed. Retrospective analysis of clinical studies published between 1990 and 2011 was performed to determine therapeutic efficacies for each clinically used modality/technique. In addition, factors that have resulted in the high degree of therapeutic recalcitrance are identified, and emerging experimental treatment strategies are addressed, including the use of photodynamic therapy, immunomodulators, angiogenesis inhibitors, hypobaric pressure, and site-specific pharmaco-laser therapy. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  1. Femtosecond laser in laser in situ keratomileusis

    PubMed Central

    Salomão, Marcella Q.; Wilson, Steven E.

    2014-01-01

    Flap creation is a critical step in laser in situ keratomileusis (LASIK). Efforts to improve the safety and predictability of the lamellar incision have fostered the development of femtosecond lasers. Several advantages of the femtosecond laser over mechanical microkeratomes have been reported in LASIK surgery. In this article, we review common considerations in management and complications of this step in femtosecond laser–LASIK and concentrate primarily on the IntraLase laser because most published studies relate to this instrument. PMID:20494777

  2. A high-efficiency regime for gas-phase terahertz lasers.

    PubMed

    Wang, Fan; Lee, Jeongwon; Phillips, Dane J; Holliday, Samuel G; Chua, Song-Liang; Bravo-Abad, Jorge; Joannopoulos, John D; Soljačić, Marin; Johnson, Steven G; Everitt, Henry O

    2018-06-11

    We present both an innovative theoretical model and an experimental validation of a molecular gas optically pumped far-infrared (OPFIR) laser at 0.25 THz that exhibits 10× greater efficiency (39% of the Manley-Rowe limit) and 1,000× smaller volume than comparable commercial lasers. Unlike previous OPFIR-laser models involving only a few energy levels that failed even qualitatively to match experiments at high pressures, our ab initio theory matches experiments quantitatively, within experimental uncertainties with no free parameters, by accurately capturing the interplay of millions of degrees of freedom in the laser. We show that previous OPFIR lasers were inefficient simply by being too large and that high powers favor high pressures and small cavities. We believe that these results will revive interest in OPFIR laser as a powerful and compact source of terahertz radiation.

  3. Publications of LASL research, 1972--1976

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petersen, L.

    1977-04-01

    This bibliography is a compilation of unclassified work done at the Los Alamos Scientific Laboratory and published during the years 1972 to 1976. Publications too late for inclusion in earlier compilations are also listed. Declassification of previously classified reports is considered to constitute publication. The bibliography includes LASL reports, journal articles, books, conference papers, papers published in congressional hearings, theses, patents, etc. The following subject areas are included: aerospace studies; analytical technology; astrophysics; atomic and molecular physics, equation of state, opacity; biology and medicine; chemical dynamics and kinetics; chemistry; cryogenics; crystallography; CTR and plasma physics; earth science and engineering; energymore » (nonnuclear); engineering and equipment; EPR, ESR, NMR studies; explosives and detonations; fission physics; health and safety; hydrodynamics and radiation transport; instruments; lasers; mathematics and computers; medium-energy physics; metallurgy and ceramics technology; neutronics and criticality studies; nuclear physics; nuclear safeguards; physics; reactor technology; solid state science; and miscellaneous (including Project Rover). (RWR)« less

  4. MALDI-MS analysis and imaging of small molecule metabolites with 1,5-diaminonaphthalene (DAN).

    PubMed

    Korte, Andrew R; Lee, Young Jin

    2014-08-01

    1,5-Diaminonaphthalene (DAN) has previously been reported as an effective matrix for matrix-assisted laser desorption ionization-mass spectrometry of phospholipids. In the current work, we investigate the use of DAN as a matrix for small metabolite analysis in negative ion mode. DAN was found to provide superior ionization to the compared matrices for MW < ~400 Da; however, 9-aminoacridine (9-AA) was found to be superior for a uridine diphosphate standard (MW 566 Da). DAN was also found to provide a more representative profile of a natural phospholipid mixture than 9-AA. Finally, DAN and 9-AA were applied for imaging of metabolites directly from corn leaf sections. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  5. Gingival displacement: Survey results of dentists' practice procedures.

    PubMed

    Ahmed, Sumitha N; Donovan, Terry E

    2015-07-01

    A high percentage of fixed prosthodontic restorations require a subgingival margin placement, which requires the practice of gingival displacement or a deflection procedure to replicate the margins in impression. The purpose of this study was to learn the different gingival displacement techniques that are currently used by dentists in their practice and to compare the current concepts of gingival displacement with previously published articles. A survey of questions pertaining to gingival deflection methods was distributed as part of continuing education (CE) course material to dentists attending CE meetings in 7 states in the U.S. and 1 Canadian province. Question topics included initial patient assessment procedures, gingival displacement methods, dentist's knowledge and assessment of systemic manifestations, and brand names of materials used. Ninety-four percent of the participants were general practitioners with 24.11 ± 12.5 years of experience. Ninety-two percent used gingival displacement cords, while 20.2% used a soft tissue laser and 32% used electrosurgery as an adjunct. Sixty percent of the dentists used displacement cords impregnated with a medicament. Of the preimpregnated cords, 29% were impregnated with epinephrine, 13% with aluminum chloride, and 18% with aluminum potassium sulfate. The study showed a steady decrease compared with results of previously published articles in the use of epinephrine as a gingival deflection medicament. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Measurement of material nonlinearity using surface acoustic wave parametric interaction and laser ultrasonics.

    PubMed

    Stratoudaki, Theodosia; Ellwood, Robert; Sharples, Steve; Clark, Matthew; Somekh, Michael G; Collison, Ian J

    2011-04-01

    A dual frequency mixing technique has been developed for measuring velocity changes caused by material nonlinearity. The technique is based on the parametric interaction between two surface acoustic waves (SAWs): The low frequency pump SAW generated by a transducer and the high frequency probe SAW generated and detected using laser ultrasonics. The pump SAW stresses the material under the probe SAW. The stress (typically <5 MPa) is controlled by varying the timing between the pump and probe waves. The nonlinear interaction is measured as a phase modulation of the probe SAW and equated to a velocity change. The velocity-stress relationship is used as a measure of material nonlinearity. Experiments were conducted to observe the pump-probe interaction by changing the pump frequency and compare the nonlinear response of aluminum and fused silica. Experiments showed these two materials had opposite nonlinear responses, consistent with previously published data. The technique could be applied to life-time predictions of engineered components by measuring changes in nonlinear response caused by fatigue.

  7. Free-beam and contact laser soft-tissue ablation in urology.

    PubMed

    Tan, Andrew H H; Gilling, Peter J

    2003-10-01

    The ablation of tissue by laser has several applications in urology. Most of the published research has been concerned with the treatment of benign prostatic hyperplasia (BPH). Other applications studied include superficial upper- and lower-tract transitional-cell carcinoma, urethral and ureteral strictures, ureteropelvic junction stenosis, and posterior urethral valves. The attraction of laser ablation for the treatment of BPH lies with the decreased morbidity in comparison with standard transurethral electrocautery resection of the prostate and the ability to remove tissue immediately and therefore allow a more rapid progression to catheter removal and early voiding. The three main laser wavelengths used in urology for tissue ablation are the neodymium:yttrium-aluminum-garnet when used with contact tips or high-density power settings, the potassium-titanyl-phosphate, and the holmium:YAG. This article reviews the published literature on the use of these laser wavelengths in soft-tissue ablation, focusing on the treatment of BPH.

  8. Developing and Modeling Fiber Amplifier Arrays

    DTIC Science & Technology

    2006-09-01

    15. A. E. Siegman , Lasers , University Science Books, ISBN 0-935702-11-5, pg 734. 16. Jianye Lu, et al, “A new method of coherent summation of laser ... Laser Division This report is published in the interest of scientific and technical information exchange...STATEMENT Approved for public release; distribution is unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT High Energy Lasers (HEL) are required for

  9. Practical in-situ determination of ortho-para hydrogen ratios via fiber-optic based Raman spectroscopy

    DOE PAGES

    Sutherland, Liese -Marie; Knudson, James N.; Mocko, Michal; ...

    2015-12-17

    An experiment was designed and developed to prototype a fiber-optic-based laser system, which measures the ratio of ortho-hydrogen to para-hydrogen in an operating neutron moderator system at the Los Alamos Neutron Science Center (LANSCE) spallation neutron source. Preliminary measurements resulted in an ortho to para ratio of 3.06:1, which is within acceptable agreement with the previously published ratio. As a result, the successful demonstration of Raman Spectroscopy for this measurement is expected to lead to a practical method that can be applied for similar in-situ measurements at operating neutron spallation sources.

  10. Practical in-situ determination of ortho-para hydrogen ratios via fiber-optic based Raman spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, Liese -Marie; Knudson, James N.; Mocko, Michal

    An experiment was designed and developed to prototype a fiber-optic-based laser system, which measures the ratio of ortho-hydrogen to para-hydrogen in an operating neutron moderator system at the Los Alamos Neutron Science Center (LANSCE) spallation neutron source. Preliminary measurements resulted in an ortho to para ratio of 3.06:1, which is within acceptable agreement with the previously published ratio. As a result, the successful demonstration of Raman Spectroscopy for this measurement is expected to lead to a practical method that can be applied for similar in-situ measurements at operating neutron spallation sources.

  11. Absolute Equation-of-State Measurement for Polystyrene from 25 - 60 Mbar Using a Spherically Converging Shock Wave

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glenzer, Siegfried

    We have developed an experimental platform for the National Ignition Facility (NIF) that uses spherically converging shock waves for absolute equation of state (EOS) measurements along the principal Hugoniot. In this Letter we present radiographic compression measurements for polystyrene that were taken at shock pressures reaching 60 Mbar (6 TPa). This significantly exceeds previously published results obtained on the Nova laser [Cauble et al., Phys. Rev. Lett. 80, 1248 (1998)] at strongly improved precision, allowing to discriminate between different EOS models. We find excellent agreement with Kohn-Sham Density Functional Theory based molecular dynamics simulations.

  12. Mode/Medium Instability in CO2 Laser

    NASA Technical Reports Server (NTRS)

    Webster, K. L.; Sung, C. C.

    1992-01-01

    Report discribes theoretical study of model/medium instability (MMI) in CO2 laser. Purposes of study to extend, to small Fresnel numbers, previous study of MMI restricted to large Fresnel numbers and to study methods of previous studies, to suppress MMI. Method of primary interest involves replacement of hard edge output mirror in laser resonator with mirror, local reflectivity of which decreases with radial distance from optical axis according to Gaussian profile.

  13. The eΠ3g state of C2: A pathway to dissociation

    NASA Astrophysics Data System (ADS)

    Welsh, B. A.; Krechkivska, O.; Nauta, K.; Bacskay, G. B.; Kable, S. H.; Schmidt, T. W.

    2017-07-01

    The lowest 13 vibrational levels, v = 0-12, of the eΠ3g state of the C2 molecule have been measured by laser-induced fluorescence of new bands of the Fox-Herzberg system. The newly observed levels, v = 5-12, which span the eΠ3g electronic state up to and beyond the first dissociation threshold of C2, were analyzed to afford highly accurate molecular constants, including band origins, and rotational and spin-orbit constants. The spin-orbit coupling constants of the previously published lowest five levels are revised in sign and magnitude, requiring an overhaul of previously published molecular constants. The analysis is supported by high level ab initio calculations. Lifetimes of all observed levels were recorded and found to be in excellent agreement with ab initio predicted values up to v = 11. v = 12 was found to exhibit a much reduced lifetime and fluorescence quantum yield, which is attributed to the onset of predissociation. This brackets the dissociation energy of ground state XΣ+1g C2 between 6.1803 and 6.2553 eV, in agreement with the Active Thermochemical Tables.

  14. Ultrafast Laser System for Producing on-Demand Single-and Multi-Photon Quantum States

    DTIC Science & Technology

    2015-09-20

    14-Mar-2015 Approved for Public Release; Distribution Unlimited Final Report: Ultrafast laser system for producing on-demand single- and multi...Champaign, IL 61820 -7406 14-Mar-2015 ABSTRACT Number of Papers published in peer-reviewed journals: Final Report: Ultrafast laser system for producing

  15. Ultrashort pulsed laser technology development program

    NASA Astrophysics Data System (ADS)

    Manke, Gerald C.

    2014-10-01

    The Department of Navy has been pursuing a technology development program for advanced, all-fiber, Ultra Short Pulsed Laser (USPL) systems via Small Business Innovative Research (SBIR) programs. Multiple topics have been published to promote and fund research that encompasses every critical component of a standard USPL system and enable the demonstration of mJ/pulse class systems with an all fiber architecture. This presentation will summarize published topics and funded programs.

  16. Flash scanning the CO2 laser: a revival of the CO2 laser in plastic surgery

    NASA Astrophysics Data System (ADS)

    Lach, Elliot

    1994-09-01

    The CO2 laser has broad clinical application yet also presents a number of practical disadvantages. These drawbacks have limited the success and utilization of this laser in plastic surgery. Flashscanner technology has recently been used for char-free CO2 laser surgery of the oropharynx, the external female genital tract, and perirectal mucosa. A commercially available optomechanical flashscanner unit `Swiftlase,' was adapted to a CO2 laser and used for treatment in numerous plastic surgical applications. Conditions and situations that were treated in this study included generalized neurofibromatosis, tuberous sclerosis, rhinophyma, viral warts, breast reconstruction, and deepithelialization prior to microsurgery or local flap transfer and/or skin graft placement. There were no significant wound healing complications. Some patients previously sustained undue scarring from conventional CO2 laser surgery. Conservative, primarily ablative CO2 laser surgery with the Swiftlase has usefulness for treatment of patients in plastic surgery including those that were previously unsuccessfully treated.

  17. Treatment of Previously Treated Facial Capillary Malformations: Results of Single-Center Retrospective Objective 3-Dimensional Analysis of the Efficacy of Large Spot 532 nm Lasers.

    PubMed

    Kwiek, Bartłomiej; Ambroziak, Marcin; Osipowicz, Katarzyna; Kowalewski, Cezary; Rożalski, Michał

    2018-06-01

    Current treatment of facial capillary malformations (CM) has limited efficacy. To assess the efficacy of large spot 532 nm lasers for the treatment of previously treated facial CM with the use of 3-dimensional (3D) image analysis. Forty-three white patients aged 6 to 59 were included in this study. Patients had 3D photography performed before and after treatment with a 532 nm Nd:YAG laser with large spot and contact cooling. Objective analysis of percentage improvement based on 3D digital assessment of combined color and area improvement (global clearance effect [GCE]) were performed. The median maximal improvement achieved during the treatment (GCE) was 59.1%. The mean number of laser procedures required to achieve this improvement was 6.2 (range 1-16). Improvement of minimum 25% (GCE25) was achieved by 88.4% of patients, a minimum of 50% (GCE50) by 61.1%, a minimum of 75% (GCE75) by 25.6%, and a minimum of 90% (GCE90) by 4.6%. Patients previously treated with pulsed dye lasers had a significantly less response than those treated with other modalities (GCE 37.3% vs 61.8%, respectively). A large spot 532 nm laser is effective in previously treated patients with facial CM.

  18. Laser power transmission

    NASA Technical Reports Server (NTRS)

    Conway, Edmund J.

    1992-01-01

    An overview of previous studies related to laser power transmission is presented. Particular attention is given to the use of solar pumped lasers for space power applications. Three general laser mechanisms are addressed: photodissociation lasing driven by sunlight, photoexcitation lasing driven directly by sunlight, and photoexcitation lasing driven by thermal radiation.

  19. Coherent Laser Radar System Theory.

    DTIC Science & Technology

    1987-11-05

    This program is aimed at developing a system theory for the emerging technology of multifunction coherent CO2 laser radars. It builds upon previous...work funded by U.S. Army Research Office contract DAAG29-80-K-0022. Keywords include: Laser radar theory, Radar system theory , and Laser speckle.

  20. Making the Leap to Desktop Publishing.

    ERIC Educational Resources Information Center

    Schleifer, Neal

    1986-01-01

    Describes one teacher's approach to desktop publishing. Explains how the Macintosh and LaserWriter were used in the publication of a school newspaper. Guidelines are offered to teachers for the establishment of a desktop publishing lab. (ML)

  1. Above scaling short-pulse ion acceleration from flat foil and ``Pizza-top Cone'' targets at the Trident laser facility

    NASA Astrophysics Data System (ADS)

    Flippo, Kirk; Hegelich, B. Manuel; Cort Gautier, D.; Johnson, J. Randy; Kline, John L.; Shimada, Tsutomu; Fernández, Juan C.; Gaillard, Sandrine; Rassuchine, Jennifer; Le Galloudec, Nathalie; Cowan, Thomas E.; Malekos, Steve; Korgan, Grant

    2006-10-01

    Ion-driven Fast Ignition (IFI) has certain advantages over electron-driven FI due to a possible large reduction in the amount of energy required. Recent experiments at the Los Alamos National Laboratory's Trident facility have yielded ion energies and efficiencies many times in excess of recent published scaling laws, leading to even more potential advantages of IFI. Proton energies in excess of 35 MeV have been observed from targets produced by the University of Nevada, Reno - dubbed ``Pizza-top Cone'' targets - at intensities of only 1x10^19 W/cm^2 with 20 joules in 600 fs. Energies in excess of 24 MeV were observed from simple flat foil targets as well. The observed energies, above any published scaling laws, are attributed to target production, preparation, and shot to shot monitoring of many laser parameters, especially the laser ASE prepulse level and laser pulse duration. The laser parameters are monitored in real-time to keep the laser in optimal condition throughout the run providing high quality, reproducible shots.

  2. Laser and somatosensory evoked potentials in amyotrophic lateral sclerosis.

    PubMed

    Isak, Baris; Tankisi, Hatice; Johnsen, Birger; Pugdahl, Kirsten; Finnerup, Nanna Brix; Fuglsang-Frederiksen, Anders

    2016-10-01

    Mild involvement of sensory nerves has been reported in previous studies in ALS patients. In this study, we assessed sensory pathways in ALS patients using laser evoked potentials (LEPs) and somatosensory evoked potentials (SSEPs). We recruited 18 ALS patients and 31 healthy subjects. Neodymium-doped yttrium aluminium perovskite (Nd:YAP)-laser was used to evoke LEPs in upper (UE) and lower (LE) extremities. N1 and N2P2 potentials were obtained from contralateral insular cortex (T3 or T4) and vertex (Cz), respectively. Median SSEPs were recorded from C3' or C4' and tibial SSEPs from Cz'. Compared to controls, ALS patients had longer N2 and P2 latencies, and smaller N2P2 amplitudes in both UE- and LE-LEPs (p<0.05), and longer latencies for median and tibial SSEPs (p<0.05). LEPs and SSEPs were abnormal in 72.2% and 56.6% patients, respectively. Cortical potentials showed that A-beta or A-delta sensory fibres, or both, were impaired in more than half of the ALS patients. The findings support that ALS is a multi-systemic disorder involving, although to a lesser degree, other systems than the motor. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Evaluation of elemental profiling methods, including laser-induced breakdown spectroscopy (LIBS), for the differentiation of Cannabis plant material grown in different nutrient solutions.

    PubMed

    El-Deftar, Moteaa M; Robertson, James; Foster, Simon; Lennard, Chris

    2015-06-01

    Laser-induced breakdown spectroscopy (LIBS) is an emerging atomic emission based solid sampling technique that has many potential forensic applications. In this study, the analytical performance of LIBS, as well as that of inductively coupled plasma mass spectrometry (ICP-MS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray microfluorescence (μXRF), was evaluated for the ability to conduct elemental analyses on Cannabis plant material, with a specific investigation of the possible links between hydroponic nutrients and elemental profiles from associated plant material. No such study has been previously published in the literature. Good correlation among the four techniques was observed when the concentrations or peak areas of the elements of interest were monitored. For Cannabis samples collected at the same growth time, the elemental profiles could be related to the use of particular commercial nutrients. In addition, the study demonstrated that ICP-MS, LA-ICP-MS and LIBS are suitable techniques for the comparison of Cannabis samples from different sources, with high discriminating powers being achieved. On the other hand, μXRF method was not suitable for the discrimination of Cannabis samples originating from different growth nutrients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Evaluation of confocal microscopy system performance.

    PubMed

    Zucker, R M; Price, O

    2001-08-01

    The confocal laser scanning microscope (CLSM) has been used by scientists to visualize three-dimensional (3D) biological samples. Although this system involves lasers, electronics, optics, and microscopes, there are few published tests that can be used to assess the performance of this equipment. Usually the CLSM is assessed by subjectively evaluating a biological/histological test slide for image quality. Although there is a use for the test slide, there are many other components in the CLSM that need to be assessed. It would be useful if tests existed that produced reference values for machine performance. The aim of this research was to develop quality assurance tests to ensure that the CLSM was stable while delivering reproducible intensity measurements with excellent image quality. Our ultimate research objective was to quantify fluorescence using a CLSM. To achieve this goal, it is essential that the CLSM be stable while delivering known parameters of performance. Using Leica TCS-SP1 and TCS-4D systems, a number of tests have been devised to evaluate equipment performance. Tests measuring dichroic reflectivity, field illumination, lens performance, laser power output, spectral registration, axial resolution, laser stability, photomultiplier tube (PMT) reliability, and system noise were either incorporated from the literature or derived in our laboratory to measure performance. These tests are also applicable to other manufacturer's systems with minor modifications. A preliminary report from our laboratory has addressed a number of the QA issues necessary to achieve CLSM performance. This report extends our initial work on the evaluation of CLSM system performance. Tests that were described previously have been modified and new tests involved in laser stability and sensitivity are described. The QA tests on the CLSM measured laser power, PMT function, dichroic reflection, spectral registration, axial registration, system noise and sensitivity, lens performance, and laser stability. Laser power stability varied between 3% and 30% due to various factors, which may include incompatibility of the fiber-optic polarization with laser polarization, thermal instability of the acoustical optical transmission filter (AOTF), and laser noise. The sensitivity of the system was measured using a 10-microm Spherotech bead and the PMTs were assessed with the CV concept (image noise). The maximum sensitivity obtainable on our TCS-SP1 system measured on the 10-microm Spherotech beads was approximately 4% for 488 nm, 2.5% for 568 nm, 20% for 647 nm, and 19% for 365 nm laser light. The values serve as a comparison to test machine sensitivity from the same or different manufacturers. QA tests are described on the CLSM to assess performance and ensure that reproducing data are obtained. It is suggested strongly that these tests be used in place of a biological/histological sample to evaluate system performance. The tests are more specific and can recognize instrument functionality and problems better than a biological/histological sample. Utilization of this testing approach will eliminate the subjective assessment of the CLSM and may allow the data from different machines to be compared. These tests are essential if one is interested in making intensity measurements on experimental samples as well as obtaining the best signal detection and image resolution from a CLSM. Published 2001 Wiley-Liss, Inc.

  5. High Resolution Frequency Measurements of Far-Infrared Laser Lines

    DTIC Science & Technology

    2010-04-01

    1 High Resolution Frequency Measurements of Far-Infrared Laser Lines Elizabeth J. Ehasz, Thomas M. Goyette, Robert H. Giles and William E. Nixon...Abstract—The frequency of four previously reported far- infrared laser lines have been measured to an accuracy of 100 kHz. These laser lines were measured ... frequencies measured here and the listed frequencies for these laser lines ranged from 59 MHz to 3.9 GHz. Index Terms—FIR Laser, Gas Laser, Molecular

  6. Laser Treatment of Nongenital Verrucae: A Systematic Review.

    PubMed

    Nguyen, Jannett; Korta, Dorota Z; Chapman, Lance W; Kelly, Kristen M

    2016-09-01

    Although cutaneous warts are common lesions, full remission is not always achieved with conventional therapies. Laser modalities including carbon dioxide (CO2), erbium:yttrium-aluminum-garnet (Er:YAG), pulsed dye (PDL), and Nd:YAG have been investigated as alternative treatments for warts. To review the use and efficacy of lasers for treating nongenital cutaneous warts. Published randomized clinical trials (RCTs), cohort studies, case series, and case reports involving laser treatment of nongenital warts were retrieved by searching PubMed with no date limits. Quality ratings of studies were based on a modified version of the Oxford Centre for Evidence-Based Medicine scheme for rating individual studies. A higher emphasis was placed on RCTs and prospective cohort studies with large sample sizes and detailed methodology. There were 35 studies published between 1989 and 2015 that comprised an aggregate of 2149 patients. Simple and recalcitrant nongenital warts treated with lasers show variable response rates (CO2 laser, 50%-100%; Er:YAG laser, 72%-100%; PDL, 47%-100%; and Nd:YAG laser, 46%-100%). Current RCTs suggest that PDL is equivalent to conventional therapies such as cryotherapy and cantharidin. Combination therapies with lasers and other agents including bleomycin, salicylic acid, and light-emitting diode have shown some success. Lasers can be an effective treatment option for both simple and recalcitrant warts. The lasers most studied for this purpose are CO2, PDL, and Nd:YAG, and of these, PDL has the fewest adverse effects. Currently, use of lasers for wart treatment is limited by lack of established treatment guidelines. Future studies are needed to compare laser modalities with each other and with nonlaser treatment options, and to establish optimal treatment protocols.

  7. Comparison of a novel high-power blue diode laser (λ=442 nm) with Ho:YAG (λ=2100 nm), Tm fiber (λ=1940 nm), and KTP (λ=532 nm) lasers for soft tissue ablation

    NASA Astrophysics Data System (ADS)

    Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and their combination may provide an alternative to conventional Ho:YAG and KTP lasers for applications in urology and other surgical fields.

  8. Adaptive Optics Imaging in Laser Pointer Maculopathy.

    PubMed

    Sheyman, Alan T; Nesper, Peter L; Fawzi, Amani A; Jampol, Lee M

    2016-08-01

    The authors report multimodal imaging including adaptive optics scanning laser ophthalmoscopy (AOSLO) (Apaeros retinal image system AOSLO prototype; Boston Micromachines Corporation, Boston, MA) in a case of previously diagnosed unilateral acute idiopathic maculopathy (UAIM) that demonstrated features of laser pointer maculopathy. The authors also show the adaptive optics images of a laser pointer maculopathy case previously reported. A 15-year-old girl was referred for the evaluation of a maculopathy suspected to be UAIM. The authors reviewed the patient's history and obtained fluorescein angiography, autofluorescence, optical coherence tomography, infrared reflectance, and AOSLO. The time course of disease and clinical examination did not fit with UAIM, but the linear pattern of lesions was suspicious for self-inflicted laser pointer injury. This was confirmed on subsequent questioning of the patient. The presence of linear lesions in the macula that are best highlighted with multimodal imaging techniques should alert the physician to the possibility of laser pointer injury. AOSLO further characterizes photoreceptor damage in this condition. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:782-785.]. Copyright 2016, SLACK Incorporated.

  9. Algebraic expressions for the polarisation response of spin-VCSELs

    NASA Astrophysics Data System (ADS)

    Adams, Mike; Li, Nianqiang; Cemlyn, Ben; Susanto, Hadi; Henning, Ian

    2018-06-01

    Closed-form expressions are derived for the relationship between the polarisation of the output and that of the pump for spin-polarised vertical-cavity surface-emitting lasers. These expressions are based on the spin-flip model (SFM) combined with the condition that the carrier recombination time is much greater than both the spin relaxation time and the photon lifetime. Allowance is also included for misalignment between the principal axes of birefringence and dichroism. These expressions yield results that are in excellent agreement both with previously published numerical calculations and with further tests for a wide range of parameters. Trends with key parameters of the SFM are easily deduced from these expressions.

  10. Cesium alignment produced by pumping with unpolarized light★

    NASA Astrophysics Data System (ADS)

    Shi, Yongqi; Weis, Antoine

    2018-04-01

    We demonstrate optical pumping on the four hyperfine components of the Cs D 1 transition by unpolarized (UPL) resonant laser light. The evidence is based on the reduction of the absorption coefficients κ 0 with increasing light power P in an uncoated Cs vapor cell with isotropic spin relaxation. For comparison we perform the same quantitative κ 0( P) measurements with linearly-polarized light (LPL) and circularly-polarized light (CPL). We find that our previously published algebraic expressions give an excellent description of all experimentally recorded induced transparency signals. Based on this we can make reliable absolute predictions for the power dependence of the spin orientation and alignment produced by pumping with LPL, CPL and UPL.

  11. CO2 laser arthroscopy-through the arthroscope

    NASA Astrophysics Data System (ADS)

    Garrick, James G.

    1990-06-01

    Orthopedists have been among the last of the specialists to utilize lasers in surgery. Even today, laser usage in orthopedics is almost exclusively limited to arthroscopy procedures. Although other types of lasers have been approved for use in orthopedics, nearly all laser-assisted arthroscopic procedures have involved the carbon dioxide laser in the knee. These techniques involve skills and problems not previously encountered. In an attempt to simplify the usage and circumvent some of the problems, we describe a means of laser energy delivery through the arthroscope.

  12. Some Words Hurt More Than Others: Semantic Activation of Pain Concepts in Memory and Subsequent Experiences of Pain.

    PubMed

    Swannell, Ellen R; Brown, Christopher A; Jones, Anthony K P; Brown, Richard J

    2016-03-01

    Theory suggests that as activation of pain concepts in memory increases, so too does subsequent pain perception. Previously, researchers have found that activating pain concepts in memory increases pain perception of subsequent painful stimuli, relative to neutral information. However, they have not attempted to quantify the nature of the association between information studied and ensuing pain perception. We subliminally presented words that had either a low or high degree of association to the word 'pain,' although this was only partially successful and some words were consciously perceived. Participants then received randomized laser heat stimuli, delivered at 1 of 3 intensity levels (low, moderate, high), and we measured the effect of this on behavioral and electrophysiological measures of pain. Participants (N = 27) rated moderate- and high-intensity laser stimuli as more painful after viewing high relative to low associates of pain; these effects remained present when we controlled for measures of mood, anxiety, and physical symptom reporting. Similar effects were observed physiologically, with higher stimulus negativity preceding after high relative to low associates and greater amplitudes for the N2 component of the laser-evoked potential after presentation of high associates in the moderate and high laser intensity conditions. These data support activation-based models of the effects of memory on pain perception. Consistent with current theories of memory and pain, we found that high, relative to low activation of pain concepts in memory increased psychological and physiological responses to laser-induced pain. The effect remained regardless of whether participants showed conscious awareness of activation. Theoretical and clinical implications are discussed. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  13. Comparison of 808, 980, and 1075nm lasers for noninvasive thermal coagulation of the canine vas deferens, ex vivo

    NASA Astrophysics Data System (ADS)

    Cilip, Christopher M.; Schweinsberger, Gino R.; Fried, Nathaniel M.

    2011-03-01

    Successful noninvasive laser coagulation of the canine vas deferens, in vivo, has been previously reported. However, the therapeutic window for treatment is relatively narrow. This study determines the dependence of vas thermal coagulation on laser wavelength for development of a noninvasive laser vasectomy procedure. Noninvasive laser coagulation of canine vas tissue, ex vivo, was performed using three commonly available near-infrared laser wavelengths: 808, 980, and 1075 nm. Each laser delivered an average power of 9.2 W, 500-ms pulse duration, pulse rate of 1.0-Hz, and 3.2-mm diameter laser spot, synchronized with cryogen spray cooling of the scrotal skin surface for a total treatment time of 60 s. Vas burst pressures were measured to determine strength of vas closure and compared to previously reported ejaculation pressures. Gross inspection of vas and scrotal skin was also performed immediately after the procedure as an indicator of thermal coagulation and skin burns. The 1075 nm laser produced the highest vas burst pressures (288 +/- 28 mmHg), significantly greater than previously reported ejaculation pressures (136 +/- 29 mmHg). The 808 nm wavelength produced insufficient vas burst pressures of 141 +/- 61 mmHg, and minor scrotal skin burns were observed in at least one case. The 980 nm wavelength was unable to produce thermal coagulation of the vas, with low burst pressures (89 +/- 58 mmHg) and severe scrotal skin burns. The 1075 nm wavelength was the only near-IR wavelength that consistently thermally coagulated the vas with a strong degree of closure and without any scrotal skin burns.

  14. Laser shock compression experiments on precompressed water in ``SG-II'' laser facility

    NASA Astrophysics Data System (ADS)

    Shu, Hua; Huang, Xiuguang; Ye, Junjian; Fu, Sizu

    2017-06-01

    Laser shock compression experiments on precompressed samples offer the possibility to obtain new hugoniot data over a significantly broader range of density-temperature phase than was previously achievable. This technique was developed in ``SG-II'' laser facility. Hugoniot data were obtained for water in 300 GPa pressure range by laser-driven shock compression of samples statically precompressed in diamond-anvil cells.

  15. Publishing Systems Same for J-Schools and Small Papers.

    ERIC Educational Resources Information Center

    Oates, William R.

    1987-01-01

    Discusses how professional publishing software allows journalism education programs to accurately create the publishing environment students will encounter at small and medium-sized newspapers. Claims that the laser jet printer is the key ingredient that is turning the personal computer revolution into a newspaper publishing revolution, describing…

  16. New applications of laser-induced breakdown and stand-off Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Snyder, Marion Lawrence

    Two novel spectroscopic applications, with the common theme of remote spectroscopy are described. In one application, laser-induced breakdown spectroscopy (LIBS) is investigated for deep ocean measurements of hydrothermal vent chemistry. This technique is demonstrated for the first time for solution measurements at pressures corresponding to those found at hydrothermal vent sites, at ocean depths of one to three kilometers. In the other application, Raman spectroscopy is investigated for stand-off detection of high explosive (HE) materials. We demonstrate several HE materials in silica can be measured at 50-meter range under ambient light conditions, a new record for this application. Chapters one through three of this dissertation contain published and recently submitted articles describing LIBS for in situ multi-elemental detection in high-pressure aqueous environments such as the deep ocean. Initial work shows the potential of single-pulse LIBS (SP-LIBS) to measure dissolved elements (e.g., Na, Ca, Li, K, and Mn) at the part-per-million level in aqueous solutions at pressures exceeding 276 bar. Dual-pulse LIBS (DP-LIBS) of high-pressure aqueous solutions is also presented. We show significant DP-LIBS enhancements are achieved through excitation of a vapor bubble formed by laser-induced breakdown of the solution with a previous laser pulse, thereby increasing the sensitivity of LIBS and allowing additional elements to be measured. Preliminary findings show that increasing solution pressure has a detrimental effect on DP-LIBS emission intensities, such that little if any DP-LIBS emission was observed above approximately 100 bar. Recent results suggest a direct relationship exists between the size of the bubble and the resulting DP-LIBS emission, and that reduction in bubble size and lifetime at elevated pressure lead to the decreased DP-LIBS emission. Chapter four contains published work examining the potential of stand-off Raman spectroscopy for remote HE detection. A small, transportable, telescope-based standoff Raman system is demonstrated for detection of HE materials, including RDX, TNT, and PETN, and simulants at distances up to 50 meters in ambient light conditions. Possible detection limits on the hundreds of parts-per-million level and detection ranges of hundreds of meters are suggested. Merits of pulsed laser excitation sources and intensified charge-coupled devices (ICCD) for detection are discussed.

  17. Low-Level Laser Therapy in Russia: History, Science and Practice

    PubMed Central

    Moskvin, Sergey Vladimirovich

    2017-01-01

    In Russia (formerly USSR) study of biomodulation action (BMA) mechanisms of low-intensity laser irradiation (LILI) began in 1964, immediately after the development of lasers. During the period from 1965 to 1972 several dozens of scientific conferences were held, hundreds of studies were published. Generally, secondary mechanisms and results of LILI effect on patients with various diseases were studied. This data was immediately implemented into practical medicine in the fields of oncology, surgery, dermatology and dentistry, and since 1974 low level laser therapy (LLLT) is included in the standard of state medical care. For 50 years no less than 1000 books were published (monographs, collections, methodical and clinical materials), thousands of researches were carried out. Primary mechanism and patterns of interaction of LILI with acceptors within cells can be represented in the following order: absorption of photon’s energy – emergence of a local temperature gradient – release of Ca2+ from intracellular stores – stimulating Ca2+–dependent processes. Understanding of this process allowed the explanation of all known secondary effects, optimized methods and extremely increased effectiveness of LLLT. Owing to the knowledge of BMA mechanisms of LILI, numerous associated and combined LLLT techniques were developed and are widely used nowadays: locally, on the projection of internal organs, laser acupuncture, reflexology, intracavitary, transdermal and intravenous laser blood illumination, magnetic-laser therapy, laser phoresis, laser-vacuum massage, biomodulation, etc. About 400 000 laser therapeutic devices are used in Russian practical healthcare. Unique, having no analogues in the world devices, are produced – red pulsed laser diodes (wavelength 635 nm, power 5-40 W, pulse duration 100 ns, frequency 10 000 Hz) are designed specially for effective laser therapy. PMID:28652897

  18. Low-Level Laser Therapy in Russia: History, Science and Practice.

    PubMed

    Moskvin, Sergey Vladimirovich

    2017-01-01

    In Russia (formerly USSR) study of biomodulation action (BMA) mechanisms of low-intensity laser irradiation (LILI) began in 1964, immediately after the development of lasers. During the period from 1965 to 1972 several dozens of scientific conferences were held, hundreds of studies were published. Generally, secondary mechanisms and results of LILI effect on patients with various diseases were studied. This data was immediately implemented into practical medicine in the fields of oncology, surgery, dermatology and dentistry, and since 1974 low level laser therapy (LLLT) is included in the standard of state medical care. For 50 years no less than 1000 books were published (monographs, collections, methodical and clinical materials), thousands of researches were carried out. Primary mechanism and patterns of interaction of LILI with acceptors within cells can be represented in the following order: absorption of photon's energy - emergence of a local temperature gradient - release of Ca 2+ from intracellular stores - stimulating Ca 2+ -dependent processes. Understanding of this process allowed the explanation of all known secondary effects, optimized methods and extremely increased effectiveness of LLLT. Owing to the knowledge of BMA mechanisms of LILI, numerous associated and combined LLLT techniques were developed and are widely used nowadays: locally, on the projection of internal organs, laser acupuncture, reflexology, intracavitary, transdermal and intravenous laser blood illumination, magnetic-laser therapy, laser phoresis, laser-vacuum massage, biomodulation, etc. About 400 000 laser therapeutic devices are used in Russian practical healthcare. Unique, having no analogues in the world devices, are produced - red pulsed laser diodes (wavelength 635 nm, power 5-40 W, pulse duration 100 ns, frequency 10 000 Hz) are designed specially for effective laser therapy.

  19. The Advanced Glaucoma Intervention Study (AGIS): 5. Encapsulated bleb after initial trabeculectomy.

    PubMed

    Schwartz, A L; Van Veldhuisen, P C; Gaasterland, D E; Ederer, F; Sullivan, E K; Cyrlin, M N

    1999-01-01

    To compare the incidence of encapsulated bleb after trabeculectomy in eyes with and without previous argon laser trabeculoplasty and to assess other risk factors for encapsulated bleb development. After medical treatment failure, eyes enrolled in the Advanced Glaucoma Intervention Study (AGIS) were randomly assigned to sequences of interventions starting with either argon laser trabeculoplasty or trabeculectomy. In the present study we compared the clinical course for 1 year after trabeculectomy in 119 eyes with failed argon laser trabeculoplasty with that of 379 eyes without previous argon laser trabeculoplasty. Data on bleb encapsulation were collected at the time that the encapsulation was diagnosed, and 3 and 6 months later. Of multiple factors examined in the AGIS data for the risk of developing encapsulated bleb, only male gender and high school graduation without further formal education were statistically significant. Encapsulation occurred in 18.5% of eyes with previous argon laser trabeculoplasty failure and 14.5% of eyes without previous argon laser trabeculoplasty (unadjusted relative risk, 1.27; 95% confidence limits = 0.81, 2.00; P = .23). After adjusting for age, gender, educational achievement, prescribed systemic beta-blockers, diabetes, visual field score, and years since glaucoma diagnosis, this difference remains statistically not significant. Four weeks after trabeculectomy, mean intraocular pressure was 7.5 mm Hg higher in eyes with (22.5 mm Hg) than without (15.0 mm Hg) encapsulated bleb; at 1 year after trabeculectomy and the resumption of medical therapy when needed, this excess was reduced to 1.4 mm Hg. This study, as did two previous studies, found male gender to be a risk factor for bleb encapsulation. Four studies, including the present study, have reported a higher rate of encapsulation in eyes with previous argon laser trabeculoplasty; in two of the studies, one of which was the present study, the rate was not statistically significantly higher; in the other two studies the rate was significantly higher. The 4-week postoperative mean intraocular pressure was higher in eyes with than without encapsulated bleb; with the resumption of medical treatment the two means converged after 1 year.

  20. Compression of Ultrafast Laser Beams

    DTIC Science & Technology

    2016-03-01

    Copyright 2003, AIP Publishing LLC. DOI: http://dx.doi.org/10.1063/1.1611998.) When designing the pulse shaper, the laser beam must completely fill the...for the design of future versions of this device. The easiest way to align the pulse shaper is to use the laser beam that will be shaped, without...Afterward, an ultrafast thin beam splitter is placed into the system after the diameter of the laser beam is reduced; this is done to monitor the beam

  1. Sun protection behavior and knowledge of patients attending laser clinic to prevent adverse events of laser: A Cross-sectional, Single Center, Tertiary Care Study.

    PubMed

    Tempark, Therdpong; Lueangarun, Suparuj; Chatproedprai, Susheera; Panchaprateep, Ratchathorn; Pongprutthipan, Marisa; Wananukul, Siriwan

    2018-06-08

    Limited data of sun protection knowledge in laser treatment patients exists therefore, preventative information should be provided by dermatologists to minimize harmful effects. To assess sun protection knowledge-behavior and knowledge to prevent adverse events from laser therapy among patients who visited a laser clinic at a tertiary university hospital in Bangkok, Thailand. This is a self-reported questionnaire, cross-sectional survey. All participants from the Laser Clinic in KCMH were recruited into the study. A Total of 385 patients were enrolled into the study; 80.5% female participants. Patients who never received laser treatment significantly lacked proper sun protection knowledge to prevent adverse events of lasers when compared to those who previous received laser treatments regarding the application of sunscreen after laser treatment (56.6% vs 17.4%, p < 0.001), consistent application of sunscreen 4-6 weeks prior to receiving laser treatment (60.5% vs 18.9%, p < 0.001), application of topical corticosteroid after laser (67.1% vs 54.1%, p = 0.048), and sun protection in the post laser area (41.9% vs 20.4%, p < 0.001). The attitude and knowledge of sun protection to prevent adverse events were significantly different among the group of educational levels and previous history of laser treatment. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  2. Retinal damage induced by mirror-reflected light from a laser pointer.

    PubMed

    Thanos, Solon; Böhm, Michael R R; Meyer zu Hörste, Melissa; Schmidt, Peter-Fritz

    2015-10-05

    The safety of laser pointers is a major public health issue since class I and II laser pointers are available worldwide and used as toys by children despite several reports cautioning such use. Here we present the first case of retinal injury caused by the laser beam of a toy laser pointer operated by a school boy and directed via the rear-view mirror of a bus into the eye of the driver. This case emphasises the great importance of cautious and appropriate use of low-energy laser pointers. Laser pointers of any class should not be made available to children because they are unlikely to understand the risks of such lasers when using them in play. 2015 BMJ Publishing Group Ltd.

  3. Delivery of macromolecules into the endothelium of whole ex vivo human cornea by femtosecond laser-activated carbon nanoparticles.

    PubMed

    Jumelle, Clotilde; Mauclair, Cyril; Houzet, Julien; Bernard, Aurélien; He, Zhiguo; Forest, Fabien; Perrache, Chantal; Gain, Philippe; Thuret, Gilles

    2016-08-01

    The targeted delivery of drugs or genes into corneal endothelial cells (ECs) during eye banking could help improve graft quality and quantity. Physical methods raising less safety concerns than viral ones, we previously adapted, for in vitro ECs, a recent innovative technique of drug delivery based on the activation of carbon nanoparticles (CNPs) by a femtosecond laser (fsL). The aim of the present pilot study was to adapt this method to enable molecule delivery into the intact endothelium of ex vivo human corneas. ECs from 40 organ-cultured corneas were perforated by photoacoustic reaction induced by irradiation of CNPs by a fsL. This enabled intracellular delivery of Alexa Fluor 488 dextran, a 4000 Da fluorescent macromolecule. The influence of increasing laser fluences (15, 20, 30 and 40 mJ/cm(2)) and of protective additives (ROCK inhibitor and poloxamer 407) on delivery and mortality rates was quantified using ImageJ. No dextran was delivered with a fluence lower than 20 mJ/cm(2). Dextran was delivered into 3% (range 0%-7%) of cells at 20 mJ/cm(2), 7% (range 2%-12%) at 30 mJ/cm(2) and reaching a median 13% (range 3%-24%) for 40 mJ/cm(2), showing that dextran uptake by ECs increased significantly with fluence. Induced mortality varied from 0% to 53% irrespective of fluence, but likely to be related with the endothelial status (EC density and morphometry, donor age, storage duration and presence of Descemet's folds). ROCK inhibitor slightly increased uptake efficiency, unlike poloxamer. However, none of them decreased the mortality induced by laser. This study shows that a macromolecule can be delivered specifically into ECs of a whole organ-cultured human cornea, using fsL-activated CNPs. The delivery rate was relatively high for a non-viral method. Further optimisation is required to understand and reduce variability in cell mortality. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Preliminary Ar-40/Ar-39 age spectrum and laser probe dating of the M1 core of the Manson Impact Structure, Iowa: A K-T boundary crater candidate

    NASA Technical Reports Server (NTRS)

    Kunk, M. J.; Snee, L. W.; French, B. M.; Harlan, S. S.; Mcgee, J. J.

    1993-01-01

    Preliminary Ar-40/Ar-39 age spectrum and laser probe dating results from new drill core from the 35-km-diameter Manson Impact Structure (MIS), Iowa indicates a reasonable possibility that the MIS is a Cretaceous-Tertiary (K-T) boundary impact event. Several different types of samples from a melt-matrix breccia, a unit of apparent crater fill intersected by the M1 core, were analyzed. Ar-40/Ar-39 results from these samples indicate a maximum age for the MIS of about 65.4 plus or minus 0.4(2 sigma) Ma. Petrographic analyses of the samples indicate a high probability that all the dated samples from the melt-matrix breccia contain relict grains that were not entirely melted or degassed at the time of impact, suggesting that the actual age of the MIS could be somewhat younger than our preliminary results indicate. The results are consistent with a previously published age estimate of shocked microcline from the MIS central uplift of 65.7 plus or minus 1.0 Ma.

  5. 3D printed fluidics with embedded analytic functionality for automated reaction optimisation

    PubMed Central

    Capel, Andrew J; Wright, Andrew; Harding, Matthew J; Weaver, George W; Li, Yuqi; Harris, Russell A; Edmondson, Steve; Goodridge, Ruth D

    2017-01-01

    Additive manufacturing or ‘3D printing’ is being developed as a novel manufacturing process for the production of bespoke micro- and milliscale fluidic devices. When coupled with online monitoring and optimisation software, this offers an advanced, customised method for performing automated chemical synthesis. This paper reports the use of two additive manufacturing processes, stereolithography and selective laser melting, to create multifunctional fluidic devices with embedded reaction monitoring capability. The selectively laser melted parts are the first published examples of multifunctional 3D printed metal fluidic devices. These devices allow high temperature and pressure chemistry to be performed in solvent systems destructive to the majority of devices manufactured via stereolithography, polymer jetting and fused deposition modelling processes previously utilised for this application. These devices were integrated with commercially available flow chemistry, chromatographic and spectroscopic analysis equipment, allowing automated online and inline optimisation of the reaction medium. This set-up allowed the optimisation of two reactions, a ketone functional group interconversion and a fused polycyclic heterocycle formation, via spectroscopic and chromatographic analysis. PMID:28228852

  6. Dynamics and noise emission of laser induced cavitation bubbles in a vortical flow field

    NASA Astrophysics Data System (ADS)

    Oweis, Ghanem F.; Choi, Jaehyug; Ceccio, Steven L.

    2004-03-01

    The sound produced by the collapse of discrete cavitation bubbles was examined. Laser-generated cavitation bubbles were produced in both a quiescent and a vortical flow. The sound produced by the collapse of the cavitation bubbles was recorded, and its spectral content was determined. It was found that the risetime of the sound pulse produced by the collapse of single, spherical cavitation bubbles in quiescent fluid exceeded that of the slew rate of the hydrophone, which is consistent with previously published results. It was found that, as collapsing bubbles were deformed by the vortical flow, the acoustic impulse of the bubbles was reduced. Collapsing nonspherical bubbles often created a sound pulse with a risetime that exceeded that of the hydrophone slew rate, although the acoustic impulse created by the bubbles was influenced largely by the degree to which the bubbles became nonspherical before collapse. The noise produced by the slow growth of cavitation bubbles in the vortex core was not detectable. These results have implications for the interpretation of hydrodynamic cavitation noise produced by vortex cavitation.

  7. Terahertz laser spectroscopy of the water dimer intermolecular vibrations. I. (D{sub 2}O){sub 2}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braly, L. B.; Cruzan, J. D.; Liu, K.

    Terahertz laser VRT spectra of the water dimer consisting of 731 transitions measured with an average precision of 2 MHz and involving four (D{sub 2}O){sub 2} intermolecular vibrations (one previously published) have been measured between 65 and 104 cm{sup -1}. The precisely determined energy level patterns differ both qualitatively and quantitatively from the predictions of several dimer potentials tested, and reveal an ordering of the intermolecular vibrations which differs dramatically from that predicted by standard normal mode analysis. Strong coupling is indicated between the low barrier tunneling motions and the intermolecular vibrations as well as among different vibrations. Particularly, themore » 83 cm{sup -1} (acceptor wag) and 90 cm{sup -1} (D{sub 2}O){sub 2} (acceptor twist) vibrations interact through a Coriolis perturbation. These spectra provide the basis for our recent determination of the water pair potential. The corresponding data set for (H{sub 2}O){sub 2} is presented in an accompanying paper. (c) 2000 American Institute of Physics.« less

  8. Astigmatic Herriott cell for optical refrigeration

    NASA Astrophysics Data System (ADS)

    Gragossian, Aram; Meng, Junwei; Ghasemkhani, Mohammadreza; Albrecht, Alexander R.; Sheik-Bahae, Mansoor

    2017-01-01

    Cooling rare-earth-doped crystals to the lowest temperature possible requires enhanced resonant absorption and high-purity crystals. Since resonant absorption decreases as the crystal is cooled, the only path forward is to increase the number of roundtrips that the laser makes inside the crystal. To achieve even lower temperatures than previously reported, we have employed an astigmatic Herriott cell to improve laser absorption at low temperatures. Preliminary results indicate improvement over previous designs. This cavity potentially enables us to use unpolarized high-power fiber lasers, and to achieve much higher cooling power for practical applications.

  9. Rewriting magnetic phase change memory by laser heating

    NASA Astrophysics Data System (ADS)

    Timmerwilke, John; Liou, Sy-Hwang; Cheng, Shu Fan; Edelstein, Alan S.

    2016-04-01

    Magnetic phase change memory (MAG PCM) consists of bits with different magnetic permeability values. The bits are read by measuring their effect on a magnetic probe field. Previously low permeability crystalline bits had been written in high permeability amorphous films of Metglas via laser heating. Here data is presented showing that by applying short laser pulses with the appropriate power to previously crystallized regions they can first be vitrified and then again crystallized. Thus, MAG PCM is rewriteable. Technical issues in processing the bits are discussed and results on thermal modeling are presented.

  10. Soviet chemical laser research: pulsed lasers. Report for 1963--1970

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ksander, Y.

    1971-11-01

    The document reviews Soviet work on pulsed chemical lasers published in the open litarature in 1963-1970. Whereas U. S. research combines the approaches of physics, quantum electrodynamics, and aerodynamics, Soviet laser research is heavily (and expertly) oriented to understanding the chemical reactions. They prefer pulsed to cw systems, concentrating on kinetics of vibrationally excited diatomic systems. The documents describe gas lasers with discharge, photolytic, and other initiation and includes research on HN/sub 3/ + CO/sub 2/ mixtures, and means of controlling reaction rates by resonant coupling and selective heating. The report also proposes a laser based on photorecombination of atoms.

  11. Advances in Lasers for the Treatment of Stones-a Systematic Review.

    PubMed

    Kronenberg, Peter; Somani, Bhaskar

    2018-05-17

    Laser lithotripsy is increasingly used worldwide and is a continuously evolving field with new and extensive research being published every year. Variable pulse length Ho:YAG lithotripters allow new lithotripsy parameters to be manipulated, and there is an effort to integrate new technologies into lithotripters. Pulsed thulium lasers seem to be a viable alternative to holmium lasers. The performance of similar laser fibers varies from manufacturer to manufacturer. Special laser fibers and "cleaving only" fiber tip preparation can be beneficial for the lithotripsy procedure. Different laser settings and the surgical technique employed can have significant impact on the success of laser lithotripsy. When safely done, complications of laser lithotripsy are rare and concern the endoscopic nature of procedure, not the technology itself, making laser lithotripsy one of the safest tools in urology. Laser lithotripsy has had several new developments and more insight has been gained in recent years with many more advances expected in the future.

  12. Laser manufacturing: strategies for dealing with the challenges

    NASA Astrophysics Data System (ADS)

    Barr, John R. M.

    2012-09-01

    Laser manufacturing in Edinburgh was initiated in 1963 by Ferranti (one of the previous names for SELEX Galileo). Since 2003 a modernized range of military lasers has been established. Innovation, both technical and in other aspects of the business, has enabled the design and manufacture of world leading laser designators and countermeasure lasers. Specific examples will be given including: the application of Geometric Algebra to resonator design; novel alignment free optical parametric oscillators; techniques for designing thermally insensitive laser diode pump heads; and methods for contamination control in lasers.

  13. Importance of the gas phase role to the prediction of energetic material behavior: An experimental study

    NASA Astrophysics Data System (ADS)

    Ali, A. N.; Son, S. F.; Asay, B. W.; Sander, R. K.

    2005-03-01

    Various thermal (radiative, conductive, and convective) initiation experiments are performed to demonstrate the importance of the gas phase role in combustion modeling of energetic materials (EM). A previously published condensed phase model that includes a predicted critical irradiance above which ignition is not possible is compared to experimental laser ignition results for octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and 2,4,6-trinitrotoluene (TNT). Experimental results conflict with the predicted critical irradiance concept. The failure of the model is believed to result from a misconception about the role of the gas phase in the ignition process of energetic materials. The model assumes that ignition occurs at the surface and that evolution of gases inhibits ignition. High speed video of laser ignition, oven cook-off and hot wire ignition experiments captures the ignition of HMX and TNT in the gas phase. A laser ignition gap test is performed to further evaluate the effect of gas phase laser absorption and gas phase disruption on the ignition process. Results indicate that gas phase absorption of the laser energy is probably not the primary factor governing the gas phase ignition observations. It is discovered that a critical gap between an HMX pellet and a salt window of 6mm±0.4mm exists below which ignition by CO2 laser is not possible at the tested irradiances of 29W /cm2 and 38W/cm2 for HMX ignition. These observations demonstrate that a significant disruption of the gas phase, in certain scenarios, will inhibit ignition, independent of any condensed phase processes. These results underscore the importance of gas phase processes and illustrate that conditions can exist where simple condensed phase models are inadequate to accurately predict the behavior of energetic materials.

  14. Verification of Wind Measurement to 450-Meter Altitude with Mobile Laser Doppler System

    DOT National Transportation Integrated Search

    1977-12-01

    The Lockheed mobile atmospheric unit is a laser Doppler velocimeter system designed for the remote sensing of winds. The capability of the laser Doppler velocimeter accurately to measure winds to 150-meter altitude has been previously demonstrated. T...

  15. A method to investigate the diffusion properties of nuclear calcium.

    PubMed

    Queisser, Gillian; Wittum, Gabriel

    2011-10-01

    Modeling biophysical processes in general requires knowledge about underlying biological parameters. The quality of simulation results is strongly influenced by the accuracy of these parameters, hence the identification of parameter values that the model includes is a major part of simulating biophysical processes. In many cases, secondary data can be gathered by experimental setups, which are exploitable by mathematical inverse modeling techniques. Here we describe a method for parameter identification of diffusion properties of calcium in the nuclei of rat hippocampal neurons. The method is based on a Gauss-Newton method for solving a least-squares minimization problem and was formulated in such a way that it is ideally implementable in the simulation platform uG. Making use of independently published space- and time-dependent calcium imaging data, generated from laser-assisted calcium uncaging experiments, here we could identify the diffusion properties of nuclear calcium and were able to validate a previously published model that describes nuclear calcium dynamics as a diffusion process.

  16. Ultralow-threshold Yb(3+):SiO(2) glass laser fabricated by the solgel process.

    PubMed

    Ostby, Eric P; Yang, Lan; Vahala, Kerry J

    2007-09-15

    A Yb-doped silica microcavity laser on a silicon chip is fabricated from a solgel thin film. The high-Q micro-toroid cavity, which has a finesse of 10,000, is evanescently coupled to an optical fiber taper. We report a threshold of 1.8 microW absorbed power that is, to the best of our knowledge, the lowest published threshold to date for any Yb-doped laser. The effect of Yb(3+) concentration on laser threshold is experimentally quantified.

  17. Study of Perturbations on High Mach Number Blast Waves in Various Gasses

    NASA Astrophysics Data System (ADS)

    Edens, A.; Adams, R.; Rambo, P.; Shores, J.; Smith, I.; Atherton, B.; Ditmire, T.

    2006-10-01

    We have performed a series of experiments examining the properties of high Mach number blast waves. Experiments were conducted on the Z-Beamlet^1 laser at Sandia National Laboratories. We created blast waves in the laboratory by using 10 J- 1000 J laser pulses to illuminate millimeter scale solid targets immersed in gas. Our experiments studied the validity of theories forwarded by Vishniac and Ryu^2-4 to explain the dynamics of perturbations on astrophysical blast waves. These experiments consisted of an examination of the evolution of perturbations of known primary mode number induced on the surface of blast waves by means of regularly spaced wire arrays. The temporal evolution of the amplitude of the induced perturbations relative to the mean radius of the blast wave was fit to a power law in time. Measurements were taken for a number of different mode numbers and background gasses and the results show qualitative agreement with previously published theories for the hydrodynamics of thin shell blast wave. The results for perturbations on nitrogen gas have been recently published^5. .^1 P. K. Rambo, I. C. Smith, J. L. Porter, et al., Applied Optics 44, 2421 (2005). ^2 D. Ryu and E. T. Vishniac, Astrophysical Journal 313, 820 (1987). ^3 D. Ryu and E. T. Vishniac, Astrophysical Journal 368, 411 (1991). ^4 E. T. Vishniac, Astrophysical Journal 274, 152 (1983). ^5 A. D. Edens, T. Ditmire, J. F. Hansen, et al., Physical Review Letters 95 (2005).

  18. Low-level lasers affect Escherichia coli cultures in hyperosmotic stress

    NASA Astrophysics Data System (ADS)

    Pinheiro, C. C.; Barboza, L. L.; Paoli, F.; Fonseca, A. S.

    2015-08-01

    Physical characteristics and practical properties have made lasers of interest for biomedical applications. Effects of low-level lasers on biological tissues could occur or be measurable depending on cell type, presence of a pathologic process or whether the cells are in an adverse environment. The objective of this work was to evaluate the survival, morphology and filamentation of E. coli cells proficient and deficient in the repair of oxidative DNA lesions exposed low-level red and infrared lasers submitted to hyperosmotic stress. Wild type and endonuclease VIII deficient E. coli cells in exponential and stationary growth phase were exposed to red and infrared lasers and submitted to hyperosmotic stress. Cell viability, filamentation phenotype and cell morphology were evaluated. Cell viability was not significantly altered but previous laser exposure induced filamentation and an altered area of stressed cells depending on physiologic condition and presence of the DNA repair. Results suggest that previous exposure to low-level red and infrared lasers could not affect viability but induced morphologic changes in cells submitted to hyperosmotic stress depending on physiologic conditions and repair of oxidative DNA lesions.

  19. Precision Spectroscopy, Diode Lasers, and Optical Frequency Measurement Technology

    NASA Technical Reports Server (NTRS)

    Hollberg, Leo (Editor); Fox, Richard (Editor); Waltman, Steve (Editor); Robinson, Hugh

    1998-01-01

    This compilation is a selected set of reprints from the Optical Frequency Measurement Group of the Time and Frequency Division of the National Institute of Standards and Technology, and consists of work published between 1987 and 1997. The two main programs represented here are (1) development of tunable diode-laser technology for scientific applications and precision measurements, and (2) research toward the goal of realizing optical-frequency measurements and synthesis. The papers are organized chronologically in five, somewhat arbitrarily chosen categories: Diode Laser Technology, Tunable Laser Systems, Laser Spectroscopy, Optical Synthesis and Extended Wavelength Coverage, and Multi-Photon Interactions and Optical Coherences.

  20. Gold Nanoparticle-Assisted Laser Therapy for the Disruption of Methicillin-Resistant Staphylococcus aureus Biofilms

    DTIC Science & Technology

    2016-11-28

    agents. The use of laser therapy to kill bacteria or to enhance the bactericidal activity of conventional antibiotics has been previously reported in the...biofilm samples and activation of the laser. This ensured highly accurate alignment of the samples with the laser beam and reduced variability in the laser... active against biofilm infections are urgently needed. The data presented here provide important information on optimization and successful

  1. Pulse circuit apparatus for gas discharge laser

    DOEpatents

    Bradley, Laird P.

    1980-01-01

    Apparatus and method using a unique pulse circuit for a known gas discharge laser apparatus to provide an electric field for preconditioning the gas below gas breakdown and thereafter to place a maximum voltage across the gas which maximum voltage is higher than that previously available before the breakdown voltage of that gas laser medium thereby providing greatly increased pumping of the laser.

  2. Heterodyne frequency measurements on N2O at 5.3 and 9.0 microns

    NASA Technical Reports Server (NTRS)

    Wells, J. S.; Jennings, D. A.; Hinz, A.; Murray, J. S.; Maki, A. G.

    1985-01-01

    Heterodyne frequency measurements on the 01(1)1-00(0)0 band of N2O have been made with the use of a tunable-diode laser, CO laser transfer oscillator, and a CO2 laser frequency synthesizer. A beat frequency was measured between a CO laser and tunable-diode laser whose frequency was locked to the peak of N2O absorption features. The frequency of the CO laser was simultaneously determined by neasuring the beat frequency with respect to a reference synthesized from two CO2 lasers. New rovibrational constants are given for the 01(1)1 state of N2O, which are in excellent agreement with previous results, although the band center is 4 MHz higher than in the previous measurements. A table for the line frequencies and their absolute uncertainties is given for the N2O absorption lines in the wave-number region from 1830 to 1920 kaysers. Some additional frequency measurements near the lower-frequency end of the 02(0)0-00(0)0 band have also been made with respect to a C-12)(0-18)2 laser.

  3. Histologic effects of resurfacing lasers.

    PubMed

    Freedman, Joshua R; Greene, Ryan M; Green, Jeremy B

    2014-02-01

    By utilizing resurfacing lasers, physicians can significantly improve the appearance of sun-damaged skin, scars, and more. The carbon dioxide and erbium:yttrium-aluminum-garnet lasers were the first ablative resurfacing lasers to offer impressive results although these earlier treatments were associated with significant downtime. Later, nonablative resurfacing lasers such as the neodymium:yttrium-aluminum-garnet laser proved effective, after a series of treatments with less downtime, but with more modest results. The theory of fractional photothermolysis has revolutionized resurfacing laser technology by increasing the safety profile of the devices while delivering clinical efficacy. A review of the histologic and molecular consequences of the resurfacing laser-tissue interaction allows for a better understanding of the devices and their clinical effects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Short-wavelength infrared laser activates the auditory neurons: comparing the effect of 980 vs. 810 nm wavelength.

    PubMed

    Tian, Lan; Wang, Jingxuan; Wei, Ying; Lu, Jianren; Xu, Anting; Xia, Ming

    2017-02-01

    Research on auditory neural triggering by optical stimulus has been developed as an emerging technique to elicit the auditory neural response, which may provide an alternative method to the cochlear implants. However, most previous studies have been focused on using longer-wavelength near-infrared (>1800 nm) laser. The effect comparison of different laser wavelengths in short-wavelength infrared (SWIR) range on the auditory neural stimulation has not been previously explored. In this study, the pulsed 980- and 810-nm SWIR lasers were applied as optical stimuli to irradiate the auditory neurons in the cochlea of five deafened guinea pigs and the neural response under the two laser wavelengths was compared by recording the evoked optical auditory brainstem responses (OABRs). In addition, the effect of radiant exposure, laser pulse width, and threshold with the two laser wavelengths was further investigated and compared. The one-way analysis of variance (ANOVA) was used to analyze those data. Results showed that the OABR amplitude with the 980-nm laser is higher than the amplitude with the 810-nm laser under the same radiant exposure from 10 to 102 mJ/cm 2 . And the laser stimulation of 980 nm wavelength has lower threshold radiant exposure than the 810 nm wavelength at varied pulse duration in 20-500 μs range. Moreover, the 810-nm laser has a wider optimized pulse duration range than the 980-nm laser for the auditory neural stimulation.

  5. Vitreous floaters: Etiology, diagnostics, and management.

    PubMed

    Milston, Rebecca; Madigan, Michele C; Sebag, J

    2016-01-01

    Vitreous is a hydrated extracellular matrix comprised primarily of water, collagens, and hyaluronan organized into a homogeneously transparent gel. Gel liquefaction results from molecular alterations with dissociation of collagen from hyaluronan and aggregation of collagen fibrils forming fibers that cause light scattering and hence symptomatic floaters, especially in myopia. With aging, gel liquefaction and weakened vitreoretinal adhesion result in posterior vitreous detachment, the most common cause of primary symptomatic floaters arising from the dense collagen matrix of the posterior vitreous cortex. Recent studies indicate that symptomatic floaters are not only more prevalent, but also have a negative impact on the quality of life that is greater than previously appreciated. We review the literature concerning management of symptomatic vitreous floaters, currently either with observation, vitrectomy, or Nd:YAG laser. Published evidence is consistent with a low-risk profile and excellent success rate for floater vitrectomy, particularly with sutureless small gauge instruments and a limited core vitrectomy without PVD induction. Nd:YAG laser treatment of floaters, reported less commonly, claims resolution of floaters ranging between 0% and 100%; however, both peer-reviewed literature and assertions on web-based nonpeer-reviewed laser vitreolysis sites remain to be substantiated, and at present only vitrectomy has proven value. Prospective studies using objective, quantitative outcome measures are required to assess the relative efficacy and safety of these two procedures as well as new therapies such as pharmacologic vitreolysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. 3D nanostructured inkjet printed graphene via UV-pulsed laser irradiation enables paper-based electronics and electrochemical devices.

    PubMed

    Das, Suprem R; Nian, Qiong; Cargill, Allison A; Hondred, John A; Ding, Shaowei; Saei, Mojib; Cheng, Gary J; Claussen, Jonathan C

    2016-09-21

    Emerging research on printed and flexible graphene-based electronics is beginning to show tremendous promise for a wide variety of fields including wearable sensors and thin film transistors. However, post-print annealing/reduction processes that are necessary to increase the electrical conductivity of the printed graphene degrade sensitive substrates (e.g., paper) and are whole substrate processes that are unable to selectively anneal/reduce only the printed graphene-leaving sensitive device components exposed to damaging heat or chemicals. Herein a pulsed laser process is introduced that can selectively irradiate inkjet printed reduced graphene oxide (RGO) and subsequently improve the electrical conductivity (Rsheet∼0.7 kΩ□(-1)) of printed graphene above previously published reports. Furthermore, the laser process is capable of developing 3D petal-like graphene nanostructures from 2D planar printed graphene. These visible morphological changes display favorable electrochemical sensing characteristics-ferricyanide cyclic voltammetry with a redox peak separation (ΔEp) ≈ 0.7 V as well as hydrogen peroxide (H2O2) amperometry with a sensitivity of 3.32 μA mM(-1) and a response time of <5 s. Thus this work paves the way for not only paper-based electronics with graphene circuits, it enables the creation of low-cost and disposable graphene-based electrochemical electrodes for myriad applications including sensors, biosensors, fuel cells, and theranostic devices.

  7. Evaluating Continuous-Time Slam Using a Predefined Trajectory Provided by a Robotic Arm

    NASA Astrophysics Data System (ADS)

    Koch, B.; Leblebici, R.; Martell, A.; Jörissen, S.; Schilling, K.; Nüchter, A.

    2017-09-01

    Recently published approaches to SLAM algorithms process laser sensor measurements and output a map as a point cloud of the environment. Often the actual precision of the map remains unclear, since SLAMalgorithms apply local improvements to the resulting map. Unfortunately, it is not trivial to compare the performance of SLAMalgorithms objectively, especially without an accurate ground truth. This paper presents a novel benchmarking technique that allows to compare a precise map generated with an accurate ground truth trajectory to a map with a manipulated trajectory which was distorted by different forms of noise. The accurate ground truth is acquired by mounting a laser scanner on an industrial robotic arm. The robotic arm is moved on a predefined path while the position and orientation of the end-effector tool are monitored. During this process the 2D profile measurements of the laser scanner are recorded in six degrees of freedom and afterwards used to generate a precise point cloud of the test environment. For benchmarking, an offline continuous-time SLAM algorithm is subsequently applied to remove the inserted distortions. Finally, it is shown that the manipulated point cloud is reversible to its previous state and is slightly improved compared to the original version, since small errors that came into account by imprecise assumptions, sensor noise and calibration errors are removed as well.

  8. The application of diode laser in the treatment of oral soft tissues lesions. A literature review.

    PubMed

    Ortega-Concepción, Daniel; Cano-Durán, Jorge A; Peña-Cardelles, Juan-Francisco; Paredes-Rodríguez, Víctor-Manuel; González-Serrano, José; López-Quiles, Juan

    2017-07-01

    Since its appearance in the dental area, the laser has become a treatment of choice in the removal of lesions in the oral soft tissues, due to the numerous advantages they offer, being one of the most used currently the diode laser. The aim of this review was to determine the efficacy and predictability of diode laser as a treatment of soft tissue injuries compared to other surgical methods. A literature review of articles published in PubMed/MEDLINE, Scopus and the Cochrane Library databases between 2007 and 2017 was performed. "Diode laser", "soft tissue", "oral cavity" and "oral surgery" were employed for the search strategy. Only articles published English or Spanish were selected. The diode laser is a minimally invasive technology that offers great advantages, superior to those of the conventional scalpel, such as reduction of bleeding, inflammation and the lower probability of scars. Its effectiveness is comparable to that of other types of lasers, in addition to being an option of lower cost and greater ease of use. Its application in the soft tissues has been evaluated, being a safe and effective method for the excision of lesions like fibromas, epulis fissuratum and the accomplishment of frenectomies. The diode laser can be used with very good results for the removal of lesions in soft tissues, being used in small exophytic lesions due to their easy application, adequate coagulation, no need to suture and the slightest inflammation and pain. Key words: Diode laser, soft tissues, oral cavity, oral surgery.

  9. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Thresholds of surface plasma formation by the interaction of laser pulses with a metal

    NASA Astrophysics Data System (ADS)

    Borets-Pervak, I. Yu; Vorob'ev, V. S.

    1995-04-01

    An analysis is made of a model of the formation of a surface laser plasma which takes account of the heating and vaporisation of thermally insulated surface microdefects. This model is used in an interpretation of experiments in which such a plasma has been formed by irradiation of a titanium target with microsecond CO2 laser pulses. A comparison with the experimental breakdown intensities is used to calculate the average sizes of microdefects and their concentration: the results are in agreement with the published data. The dependence of the delay time of plasma formation on the total energy in a laser pulse is calculated.

  10. Development of high damage threshold laser-machined apodizers and gain filters for laser applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rambo, Patrick; Schwarz, Jens; Kimmel, Mark

    We have developed high damage threshold filters to modify the spatial profile of a high energy laser beam. The filters are formed by laser ablation of a transmissive window. The ablation sites constitute scattering centers which can be filtered in a subsequent spatial filter. Finally, by creating the filters in dielectric materials, we see an increased laser-induced damage threshold from previous filters created using ‘metal on glass’ lithography.

  11. Development of high damage threshold laser-machined apodizers and gain filters for laser applications

    DOE PAGES

    Rambo, Patrick; Schwarz, Jens; Kimmel, Mark; ...

    2016-09-27

    We have developed high damage threshold filters to modify the spatial profile of a high energy laser beam. The filters are formed by laser ablation of a transmissive window. The ablation sites constitute scattering centers which can be filtered in a subsequent spatial filter. Finally, by creating the filters in dielectric materials, we see an increased laser-induced damage threshold from previous filters created using ‘metal on glass’ lithography.

  12. Numerical and experimental determination of weld pool shape during high-power diode laser welding

    NASA Astrophysics Data System (ADS)

    Klimpel, Andrzej; Lisiecki, Aleksander; Szymanski, Andrzej; Hoult, Anthony P.

    2003-10-01

    In this paper, results of investigations on the shape of weld pool during High Power Diode Laser (HPDL) welding are presented. The results of tests showed that the shape of weld pool and mechanism of laser welding with a rectangular pattern of 808 nm laser radiation differs distinctly from previous laser welding mechanisms. For all power densities the conduction mode welds were observed and weld pool geometry depends significantly on the welding parameters.

  13. Measurement of the azimuthal dependence of cross-polarized lidar returns and its relation to optical depth.

    PubMed

    Roy, Nathalie; Roy, Gilles; Bissonnette, Luc R; Simard, Jean-Robert

    2004-05-01

    We measure with a gated intensified CCD camera the cross-polarized backscattered light from a linearly polarized laser beam penetrating a cloud made of spherical particles. In accordance with previously published results we observe a clear azimuthal pattern in the recorded images. We show that the pattern is symmetrical, that it originates from second-order scattering, and that higher-order scattering causes blurring that increases with optical depth. We also find that the contrast in the symmetrical features can be related to measurement of the optical depth. Moreover, when the blurring contributions are identified and subtracted, the resulting pattern provides a pure second-order scattering measurement that can be used for retrieval of droplet size.

  14. Feasibility of supersonic diode pumped alkali lasers: Model calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barmashenko, B. D.; Rosenwaks, S.

    The feasibility of supersonic operation of diode pumped alkali lasers (DPALs) is studied for Cs and K atoms applying model calculations, based on a semi-analytical model previously used for studying static and subsonic flow DPALs. The operation of supersonic lasers is compared with that measured and modeled in subsonic lasers. The maximum power of supersonic Cs and K lasers is found to be higher than that of subsonic lasers with the same resonator and alkali density at the laser inlet by 25% and 70%, respectively. These results indicate that for scaling-up the power of DPALs, supersonic expansion should be considered.

  15. General Linewidth Formula for Steady-State Multimode Lasing in Arbitrary Cavities

    NASA Astrophysics Data System (ADS)

    Chong, Y. D.; Stone, A. Douglas

    2012-08-01

    A formula for the laser linewidth of arbitrary cavities in the multimode nonlinear regime is derived from a scattering analysis of the solutions to semiclassical laser theory. The theory generalizes previous treatments of the effects of gain and openness described by the Petermann factor. The linewidth is expressed using quantities based on the nonlinear scattering matrix, which can be computed from steady-state ab initio laser theory; unlike previous treatments, no passive cavity or phenomenological parameters are involved. We find that low cavity quality factor, combined with significant dielectric dispersion, can cause substantial deviations from the Shawlow-Townes-Petermann theory.

  16. Structural and magnetic fluence dependence in cobalt titanate thin films synthesized by pulse laser deposition

    NASA Astrophysics Data System (ADS)

    Prisbrey, Shon Thomas

    Knowledge of the fundamental structure and magnetic characteristics of dilute magnetic semiconductors (DMSs) is an essential step towards the development of spin-polarized electronics (spintronics). Recently (2001), the report of ferromagnetism in cobalt-doped anatase titania films synthesized by pulse laser deposition (PLD) elicited interest as a possible DMS oxide. Other investigations of the CoxTi1-xO2-delta material system, utilizing a myriad of deposition techniques, yielded conflicting results as to the source of magnetism and the local environment of the deposited cobalt. No complete characterization of PLD synthesized films has been reported. This dissertation quantifies the effect of laser fluence on film morphology, structure, and magnetic properties by fully characterizing CoxTi1-x O2-delta films grown under optimal PLD deposition conditions that were identified separately in prior published work. The construction of a custom PLD system that provided repeatable laser/target interaction via a combination of fluence and target movement is addressed. A brief outline of magnetism and its relation to structure is also given. The remainder of the dissertation details the effect of laser fluence on Co0.049Ti0.951O2-delta and Co 0.038Ti0.962O2-delta films. Film structure, morphology, and magnetic properties were determined for illumination conditions corresponding to laser fluences varying from 0.57 to 1.37 J/cm2. The local cobalt environment is strongly correlated with laser fluence. Cobalt in 4.9% concentration films grown with a laser fluence between 0.7 and 0.93 J/cm2 were octahedrally coordinated, as were 3.8% films grown with a fluence less than 0.93 J/cm2. Departure of the laser fluence from these ranges results in a multitude of cobalt environments in the films. The film magnetization is observed to be a function of laser fluence with a maximum moment of ˜3.19 muB per cobalt atom occurring at 0.93 J/cm2 in the 4.9% films and ˜1.9 muB per cobalt atom at 0.57 J/cm2 in the 3.8% films. There is no evidence of cobalt segregation and subsequent formation of metallic cobalt in the high moment films. A departure in laser fluence from the maximum moment conditions results in a drop in moment to ˜1 muB. An appendix detailing previous work that investigated iridium as an oxidation resistant capping layer is also included.

  17. In space performance of the lunar orbiter laser altimeter (LOLA) laser transmitter

    NASA Astrophysics Data System (ADS)

    Yu, Anthony W.; Shaw, George B.; Novo-Gradac, Ann Marie; Li, Steven X.; Cavanaugh, John

    2011-11-01

    In this paper we present the final configuration of the space flight laser transmitter as delivered to the Lunar Orbiter Laser Altimeter (LOLA) instrument along with some in-space operation performance data. The LOLA instrument is designed to map the lunar surface and provide unprecedented data products in anticipation of future manned flight missions. The laser transmitter has been operating on orbit at the Moon continuously since July 2009 and accumulated over 1.8 billion laser shots in space. The LOLA laser transmitter design has heritage dated back to the MOLA laser transmitter launched more than 10 years ago and incorporates lessons learned from previous laser altimeter missions at NASA Goddard Space Flight Center.

  18. Large volume multiple-path nuclear pumped laser

    NASA Technical Reports Server (NTRS)

    Hohl, F.; Deyoung, R. J. (Inventor)

    1981-01-01

    Large volumes of gas are excited by using internal high reflectance mirrors that are arranged so that the optical path crosses back and forth through the excited gaseous medium. By adjusting the external dielectric mirrors of the laser, the number of paths through the laser cavity can be varied. Output powers were obtained that are substantially higher than the output powers of previous nuclear laser systems.

  19. Laser eye protection bleaching with femtosecond exposure

    NASA Astrophysics Data System (ADS)

    Stolarski, Jacob; Hayes, Kristy L.; Thomas, Robert J.; Noojin, Gary D.; Stolarski, David J.; Rockwell, Benjamin A.

    2003-06-01

    The measured optical density of various laser eye protection samples is presented as a function of irradiance using femtosecond laser pulses. We show that the protective quality of some eyewear degrades as irradiance increases. In previous studies this problem has been demonstrated for samples irradiated by nanosecond pulses, but the current study shows that some modern laser eye protection seems to be robust except for the irradiance level possible with ultrashort laser pulse exposure. We discuss the most likely saturation mechanisms in this pulse duration regime and its relevance to laser safety.

  20. Mid-Infrared Photonic Devices Fabricated by Ultrafast Laser Inscription

    DTIC Science & Technology

    2016-07-01

    active and passive photonic devices in single crystal, ceramic and glass substrates. This range of devices span applications such as: astrophysics [16...waveguide has been published this year in Applied Physics Letters. Reference: Macdonald, J.R., et al., Compact mid-infrared Cr:ZnSe channel...waveguide laser. Applied Physics Letters, 2013. 102(16): p. 161110. High efficiency circular cladding WG laser The initial demonstration of square double

  1. New Refractive Surgery Procedures and Their Implications for Aviation Safety

    DTIC Science & Technology

    2006-04-01

    airmen with laser refractive surgery, i.e., photorefractive keratectomy ( PRK ) and laser in situ keratomileusis ( LASIK ). A reference guide on refractive...surgery was published in September of 1998 (DOT/FAA/AM-98/25); however, at that time long-term clinical data on PRK and LASIK were not available...fractive surgery procedures (Photorefractive Keratectomy [ PRK ], Laser1 in situ Keratomileusis [ LASIK ]) and to assist Aviation Medical Examiners in

  2. A THRESHOLD ANALYSIS OF THE TUNNEL INJECTION LASER.

    DTIC Science & Technology

    A new threshold analysis of the tunnel injection laser is given that differs from previous treatments in that an additional loss mechanism is...a slight increase in the threshold current density of the tunnel laser. For a device one millimeter long composed of GaAs at 77K, the threshold

  3. Feasible Application Area Study for Linear Laser Cutting in Paper Making Processes

    NASA Astrophysics Data System (ADS)

    Happonen, A.; Stepanov, A.; Piili, H.

    Traditional industry sectors, like paper making industry, tend to stay within well-known technology rather than going forward towards promising, but still quite new technical solutions and applications. This study analyses the feasibility of the laser cutting in large-scale industrial paper making processes. Aim was to reveal development and process related challenges and improvement potential in paper making processes by utilizing laser technology. This study has been carried out, because there still seems to be only few large-scale industrial laser processing applications in paper converting processes worldwide, even in the beginning of 2010's. Because of this, the small-scale use of lasers in paper material manufacturing industry is related to a shortage of well-known and widely available published research articles and published measurement data (e.g. actual achieved cut speeds with high quality cut edges, set-up times and so on). It was concluded that laser cutting has strong potential in industrial applications for paper making industries. This potential includes quality improvements and a competitive advantage for paper machine manufacturers and industry. The innovations have also added potential, when developing new paper products. An example of these kinds of products are ones with printed intelligence, which could be a new business opportunity for the paper industries all around the world.

  4. Laser/Optical Data Base Products: Evaluation and Selection.

    ERIC Educational Resources Information Center

    Nicholls, Paul Travis

    1988-01-01

    The practical advice for the evaluation of laser/optical data disk materials (e.g., CD-ROM) is based on a review of the relevant literature. An evaluation framework is outlined and collection development tools and sources of published reviews are identified. (34 references) (Author/CLB)

  5. LASER MEDICINE: Effect of laser radiation absorption in water and blood on the optimal wavelength for endovenous obliteration of varicose veins

    NASA Astrophysics Data System (ADS)

    Zhilin, K. M.; Minaev, V. P.; Sokolov, Aleksandr L.

    2009-08-01

    This work examines laser radiation absorption in water and blood at the wavelengths that are used in endovenous laser treatment (EVLT): 0.81-1.06, 1.32, 1.47, 1.5 and 1.56 μm. It is shown that the best EVLT conditions are ensured by 1.56-μm radiation. Analysis of published data suggests that even higher EVLT efficacy may be achieved at wavelengths of 1.68 and 1.7 μm.

  6. Conditioning in laser skin resurfacing - betulin emulsion and skin recovery.

    PubMed

    Metelmann, Hans-Robert; Podmelle, Fred; Waite, Peter D; Müller-Debus, Charlotte Friederieke; Hammes, Stefan; Funk, Wolfgang

    2013-04-01

    Laser skin resurfacing of the face by CO₂-laser ablation is causing superficial wounds that need rapid recovery to reduce the risk of infection, the risk of chronification and as a result the risk of unaesthetic scars. The question being addressed by this study is to demonstrate benefit of betulin emulsion skin care after CO₂-laser wounds. The outcome of this aesthetic comparison between betulin emulsion, moist wound dressing and gauze covering in promoting the recovery process in laser skin ablation is to demonstrate improved aesthetic benefit for the patient. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Hydrodynamic modeling of laser interaction with micro-structured targets

    DOE PAGES

    Velechovsky, Jan; Limpouch, Jiri; Liska, Richard; ...

    2016-08-03

    A model is developed for numerical simulations of laser absorption in plasmas made of porous materials, with particular interest in low-density foams. Laser absorption is treated on two spatial scales simultaneously. At the microscale, the expansion of a thin solid pore wall is modeled in one dimension and the information obtained is used in the macroscale fluid simulations for the description of the plasma homogenization behind the ionization front. This two-scale laser absorption model is implemented in the arbitrary Lagrangian–Eulerian hydrocode PALE. In conclusion, the numerical simulations of laser penetration into low-density foams compare favorably with published experimental data.

  8. The need to certify products to CDRH Regulations.

    PubMed

    Weiner, R

    1994-06-01

    Laser products that are sold in the United States are required to comply with the regulations published by the Center for Devices and Radiological Health (CDRH) within the US Food and Drug Administration [1]. The need to certify products is straightforward in most instances, however, the applicability of the regulations is not as clear for: lasers sold only to Original Equipment Manufacturers (OEMs) as components for incorporation into end-use products, end-use products that contain lasers which have already been certified by their manufacturers, and end-use products that are being imported into the US and that already comply with international laser safety standards. This article will discuss these applications in an attempt to clarify the need for certification by laser product manufacturers and importers. The discussion applies equally for lasers and laser systems.

  9. Comparisons of angularly and spectrally resolved Bremsstrahlung measurements to two-dimensional multi-stage simulations of short-pulse laser-plasma interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, C. D.; Kemp, A. J.; Pérez, F.

    2013-05-15

    A 2-D multi-stage simulation model incorporating realistic laser conditions and a fully resolved electron distribution handoff has been developed and compared to angularly and spectrally resolved Bremsstrahlung measurements from high-Z planar targets. For near-normal incidence and 0.5-1 × 10{sup 20} W/cm{sup 2} intensity, particle-in-cell (PIC) simulations predict the existence of a high energy electron component consistently directed away from the laser axis, in contrast with previous expectations for oblique irradiation. Measurements of the angular distribution are consistent with a high energy component when directed along the PIC predicted direction, as opposed to between the target normal and laser axis asmore » previously measured.« less

  10. Laser in situ keratomileusis enhancements with the Ziemer FEMTO LDV femtosecond laser following previous LASIK treatments.

    PubMed

    Pietilä, Juhani; Huhtala, Anne; Mäkinen, Petri; Uusitalo, Hannu

    2013-02-01

    The aim of this paper is to present the accuracy, predictability, and safety outcomes of LASIK enhancements performed with the FEMTO LDV femtosecond laser (Ziemer Ophthalmic Systems, Port, Switzerland) and the Allegretto Wave Concerto 500 Hz excimer laser (Wavelight AG, Erlangen, Germany), following previous LASIK treatments. FEMTO LDV was used for flap creation in 85 previously LASIK-treated eyes of 62 patients. The intended flap thickness was 90 μm in 81 eyes and 140 μm in 4 eyes. The size of the suction ring was 9.0 mm in 72 eyes and 9.5 mm in 13 eyes. Flap dimensions were measured and correlated to preoperative characteristics. With the intended flap thickness of 90 μm in previously LASIK-treated eyes, the actual flap thickness was 90.2 ± 6.6 μm (range 80-122), and the flap diameter was 9.2 ± 0.2 mm (range 8.7-9.9). The mean hinge length was 4.0 ± 0.2 mm (range 3.0-4.8). Flap thickness correlated positively with patient age and hinge length. Complications were reported in 12 eyes (14.1 %). Most of the complications were very mild, and none of them prevented further refractive laser treatment. One eye lost two Snellen lines of best spectacle-corrected visual acuity. Femtosecond LASIK enhancement is warranted only in rare cases. Surgical experience is needed and special caution must be practiced. For cases of a primary free cap, femtosecond LASIK is not recommended.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ediger, M.N.

    The laser-induced fluorescence spectrum of rabbit cornea irradiated at ablative intensities was measured. This system directly measured the radiant exposure of fluorescence transmitted through the cornea when the anterior surface of the cornea was irradiated by an ArF excimer laser. Evidence of changing spectral characteristics as a function of total laser dose suggests photochemical changes in the cornea may be occurring. Results are compared with previous data of laser-induced fluorescence in other models and detection schemes.

  12. Ablation-cooled material removal with ultrafast bursts of pulses

    NASA Astrophysics Data System (ADS)

    Kerse, Can; Kalaycıoğlu, Hamit; Elahi, Parviz; Çetin, Barbaros; Kesim, Denizhan K.; Akçaalan, Önder; Yavaş, Seydi; Aşık, Mehmet D.; Öktem, Bülent; Hoogland, Heinar; Holzwarth, Ronald; Ilday, Fatih Ömer

    2016-09-01

    The use of femtosecond laser pulses allows precise and thermal-damage-free removal of material (ablation) with wide-ranging scientific, medical and industrial applications. However, its potential is limited by the low speeds at which material can be removed and the complexity of the associated laser technology. The complexity of the laser design arises from the need to overcome the high pulse energy threshold for efficient ablation. However, the use of more powerful lasers to increase the ablation rate results in unwanted effects such as shielding, saturation and collateral damage from heat accumulation at higher laser powers. Here we circumvent this limitation by exploiting ablation cooling, in analogy to a technique routinely used in aerospace engineering. We apply ultrafast successions (bursts) of laser pulses to ablate the target material before the residual heat deposited by previous pulses diffuses away from the processing region. Proof-of-principle experiments on various substrates demonstrate that extremely high repetition rates, which make ablation cooling possible, reduce the laser pulse energies needed for ablation and increase the efficiency of the removal process by an order of magnitude over previously used laser parameters. We also demonstrate the removal of brain tissue at two cubic millimetres per minute and dentine at three cubic millimetres per minute without any thermal damage to the bulk.

  13. Ablation-cooled material removal with ultrafast bursts of pulses.

    PubMed

    Kerse, Can; Kalaycıoğlu, Hamit; Elahi, Parviz; Çetin, Barbaros; Kesim, Denizhan K; Akçaalan, Önder; Yavaş, Seydi; Aşık, Mehmet D; Öktem, Bülent; Hoogland, Heinar; Holzwarth, Ronald; Ilday, Fatih Ömer

    2016-09-01

    The use of femtosecond laser pulses allows precise and thermal-damage-free removal of material (ablation) with wide-ranging scientific, medical and industrial applications. However, its potential is limited by the low speeds at which material can be removed and the complexity of the associated laser technology. The complexity of the laser design arises from the need to overcome the high pulse energy threshold for efficient ablation. However, the use of more powerful lasers to increase the ablation rate results in unwanted effects such as shielding, saturation and collateral damage from heat accumulation at higher laser powers. Here we circumvent this limitation by exploiting ablation cooling, in analogy to a technique routinely used in aerospace engineering. We apply ultrafast successions (bursts) of laser pulses to ablate the target material before the residual heat deposited by previous pulses diffuses away from the processing region. Proof-of-principle experiments on various substrates demonstrate that extremely high repetition rates, which make ablation cooling possible, reduce the laser pulse energies needed for ablation and increase the efficiency of the removal process by an order of magnitude over previously used laser parameters. We also demonstrate the removal of brain tissue at two cubic millimetres per minute and dentine at three cubic millimetres per minute without any thermal damage to the bulk.

  14. High-Resolution In Vivo Imaging of Regimes of Laser Damage to the Primate Retina

    PubMed Central

    Pocock, Ginger M.; Oliver, Jeffrey W.; Specht, Charles S.; Estep, J. Scot; Noojin, Gary D.; Schuster, Kurt; Rockwell, Benjamin A.

    2014-01-01

    Purpose. To investigate fundamental mechanisms of regimes of laser induced damage to the retina and the morphological changes associated with the damage response. Methods. Varying grades of photothermal, photochemical, and photomechanical retinal laser damage were produced in eyes of eight cynomolgus monkeys. An adaptive optics confocal scanning laser ophthalmoscope and spectral domain optical coherence tomographer were combined to simultaneously collect complementary in vivo images of retinal laser damage during and following exposure. Baseline color fundus photography was performed to complement high-resolution imaging. Monkeys were perfused with 10% buffered formalin and eyes were enucleated for histological analysis. Results. Laser energies for visible retinal damage in this study were consistent with previously reported damage thresholds. Lesions were identified in OCT images that were not visible in direct ophthalmoscopic examination or fundus photos. Unique diagnostic characteristics, specific to each damage regime, were identified and associated with shape and localization of lesions to specific retinal layers. Previously undocumented retinal healing response to blue continuous wave laser exposure was recorded through a novel experimental methodology. Conclusion. This study revealed increased sensitivity of lesion detection and improved specificity to the laser of origin utilizing high-resolution imaging when compared to traditional ophthalmic imaging techniques in the retina. PMID:24891943

  15. DOE-HEP Final Report for 2013-2016: Studies of plasma wakefields for high repetition-rate plasma collider, and Theoretical study of laser-plasma proton and ion acceleration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsouleas, Thomas C.; Sahai, Aakash A.

    2016-08-08

    There were two goals for this funded project: 1. Studies of plasma wakefields for high repetition-rate plasma collider, and 2. Theoretical study of laser-plasma proton and ion acceleration. For goal 1, an analytical model was developed to determine the ion-motion resulting from the interaction of non-linear “blow-out” wakefields excited by beam-plasma and laser-plasma interactions. This is key to understanding the state of the plasma at timescales of 1 picosecond to a few 10s of picoseconds behind the driver-energy pulse. More information can be found in the document. For goal 2, we analytically and computationally analyzed the longitudinal instabilities of themore » laser-plasma interactions at the critical layer. Specifically, the process of “Doppler-shifted Ponderomotive bunching” is significant to eliminate the very high-energy spread and understand the importance of chirping the laser pulse frequency. We intend to publish the results of the mixing process in 2-D. We intend to publish Chirp-induced transparency. More information can be found in the document.« less

  16. Laser Doppler velocimetry for continuous flow solar-pumped iodine laser system

    NASA Technical Reports Server (NTRS)

    Tabibi, Bagher M.; Lee, Ja H.

    1991-01-01

    A laser Doppler velocimetry (LDV) system was employed to measure the flow velocity profile of iodide vapor inside laser tubes of 36 mm ID and 20 mm ID. The LDV, which was operated in the forward scatter mode used a low power (15 mW) He-Ne laser beam. Velocity ranges from 1 m/s was measured to within one percent accuracy. The flow velocity profile across the laser tube was measured and the intensity of turbulence was determined. The flow of iodide inside the laser tube demonstrated a mixture of both turbulence and laminar flow. The flowmeter used for the laser system previously was calibrated with the LDV and found to be in good agreement.

  17. Ablative skin resurfacing.

    PubMed

    Agrawal, Nidhi; Smith, Greg; Heffelfinger, Ryan

    2014-02-01

    Ablative laser resurfacing has evolved as a safe and effective treatment for skin rejuvenation. Although traditional lasers were associated with significant thermal damage and lengthy recovery, advances in laser technology have improved safety profiles and reduced social downtime. CO2 lasers remain the gold standard of treatment, and fractional ablative devices capable of achieving remarkable clinical improvement with fewer side effects and shorter recovery times have made it a more practical option for patients. Although ablative resurfacing has become safer, careful patient selection and choice of suitable laser parameters are essential to minimize complications and optimize outcomes. This article describes the current modalities used in ablative laser skin resurfacing and examines their efficacy, indications, and possible side effects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Use of i-gel for laser ablation of a bronchial lesion.

    PubMed

    Garg, Rakesh; Thakore, Sakshi; Madan, Karan; Mohan, Anant

    2017-10-24

    The use of laser for airway lesions requires airway management. Usual options include special laser-resistant endotracheal tubes. The use of supraglottic devices have been described in the literature. Laryngeal mask airway carries the risk of cuff damage during the use of laser. i-gel is made of thermoplastic material and does not require air inflation and thus potentially reduce the risk of cuff rupture. i-gel use in laser surgeries has not been described in the literature. We present successful airway management in laser surgery for bronchial tumour using i-gel. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Experimental Investigation of the Reflection Mode Micro Laser Propulsion under Highly Frequent and Multi Pulse Laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Xinghua; Cai Jian; Li Long

    Micro laser propulsion used for some space tasks of micro-satellites are preferred to providing small thrust and high specific impulse while keeping power consumption low. Most previous work on micro laser propulsion are about transmission mode (T-mode) using a CW laser. In this article, a pulsed fiber laser is used to study the micro laser propulsion performance under reflection mode. Multi pulse (ranged from 100 to 2000) tests are conducted on a double base propellant with the vacuum less than 10 Pa. The laser frequency is 20 kHz and two kinds of instantaneous power density 4.77x10{sup 6} W/cm{sup 2} andmore » 2.39x10{sup 7} W/cm{sup 2} are used. It is found that the momentum coupling coefficient C{sub m} and the mean thrust F increases with the increasing pulse numbers, which is different to the previous work. By adjusting the irradiation time T, it is easy to get a large mean thrust, up to mN. When the energy density is the same, C{sub m}, I{sub sp}, F and {eta} increase with the increasing power density. Also I{sub sp} and {eta} are very low, laser ablation is insufficiently under the current condition. 3D Morphology of the ablation hole is obtained by confocal microscope for the first time.« less

  20. Erythema after laser skin resurfacing.

    PubMed

    Ruiz-Esparza, J; Barba Gomez, J M; Gomez de la Torre, O L; David, L

    1998-01-01

    Erythema after laser skin resurfacing is seen by many as a necessary evil in order to get good results from the procedure. A critical review of widely accepted concepts may lead to diminishing the length of postoperative erythema in patients undergoing laser resurfacing. The authors report on two previously unrecognized factors in the causation of this problem.

  1. Laboratory simulation of energetic flows of magnetospheric planetary plasma

    NASA Astrophysics Data System (ADS)

    Shaikhislamov, I. F.; Posukh, V. G.; Melekhov, A. V.; Boyarintsev, E. L.; Zakharov, Yu P.; Prokopov, P. A.; Ponomarenko, A. G.

    2017-01-01

    Dynamic interaction of super-sonic counter-streaming plasmas moving in dipole magnetic dipole is studied in laboratory experiment. First, a quasi-stationary flow is produced by plasma gun which forms a magnetosphere around the magnetic dipole. Second, explosive plasma expanding from inner dipole region outward is launch by laser beams focused at the surface of the dipole cover. Laser plasma is energetic enough to disrupt magnetic field and to sweep through the background plasma for large distances. Probe measurements showed that far from the initially formed magnetosphere laser plasma carries within itself a magnetic field of the same direction but order of magnitude larger in value than the vacuum dipole field at considered distances. Because no compression of magnetic field at the front of laser plasma was observed, the realized interaction is different from previous experiments and theoretical models of laser plasma expansion into uniform magnetized background. It was deduced based on the obtained data that laser plasma while expanding through inner magnetosphere picks up a magnetized shell formed by background plasma and carries it for large distances beyond previously existing magnetosphere.

  2. QCL seeded, ns-pulse, multi-line, CO2 laser oscillator for laser-produced-plasma extreme-UV source

    NASA Astrophysics Data System (ADS)

    Nowak, Krzysztof Michał; Suganuma, Takashi; Kurosawa, Yoshiaki; Ohta, Takeshi; Kawasuji, Yasufumi; Nakarai, Hiroaki; Saitou, Takashi; Fujimoto, Junichi; Mizoguchi, Hakaru; Sumitani, Akira; Endo, Akira

    2017-01-01

    Successful merger of state-of-the-art, semiconductor quantum-cascade lasers (QCL), with the mature CO2 laser technology, resulted in a delivery of highly-desired qualities of CO2 laser output that were not available previously without much effort. These qualities, such as multi-line operation, excellent spectro-temporal stability and pulse waveform control, became available from a single device of moderate complexity. This paper describes the operation principle and the unique properties of the solid{state seeded CO2 laser, invented for an application in laser-produced-plasma (LPP), extreme-UV (EUV) light source.

  3. Pulsed dye laser treatment of rosacea using a novel 15 mm diameter treatment beam.

    PubMed

    Bernstein, Eric F; Schomacker, Kevin; Paranjape, Amit; Jones, Christopher J

    2018-04-10

    The pulsed-dye laser has been used to treat facial redness and rosacea for decades. Recent advances in dye laser technology enable 50% higher output energies supporting 50% larger treatment areas, and beam-diameters up to 15 mm with clinically-relevant fluences. In this study, we investigate this novel pulsed-dye laser using a 15 mm diameter beam for treatment of rosacea. Twenty subjects with erythemato-telangiectatic rosacea were enrolled in the study. A total of 4 monthly treatments were administered, first treating linear vessels with a 3 × 10 mm elliptical beam, then diffuse redness with a 15-mm diameter circular beam. Blinded assessment of digital, cross-polarized photographs taken 2 months following the last treatment was performed using an 11-point clearance scale. Nineteen subjects completed the study. Blinded reviewers correctly identified baseline photos in 55 out of the total of 57 images (96.5%). The blinded reviewers scored 17 of the 19 subjects with an improvement greater than 40%, and 11 of the 19 subjects greater than 50%. The average improvement was 53.9%. Side effects were limited to mild edema, mild to moderate erythema, and mild to moderate bruising. This study demonstrates that a newly designed pulsed-dye laser having a novel 15-mm diameter treatment beam improves the appearance of rosacea with a favorable safety profile. Lasers Surg. Med. 9999:1-5, 2018. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

  4. Investigation of various factors influencing Raman spectra interpretation with the use of likelihood ratio approach.

    PubMed

    Michalska, Aleksandra; Martyna, Agnieszka; Zadora, Grzegorz

    2018-01-01

    The main aim of this study was to verify whether selected analytical parameters may affect solving the comparison problem of Raman spectra with the use of the likelihood ratio (LR) approach. Firstly the LR methodologies developed for Raman spectra of blue automotive paints obtained with the use of 785nm laser source (results published by the authors previously) were implemented for good quality spectra recorded for these paints with the use of 514.5nm laser source. For LR models construction two types of variables were used i.e. areas under selected pigments bands and coefficients derived from discrete wavelet transform procedure (DWT). Few experiments were designed for 785nm and 514.5nm Raman spectra databases after constructing well performing LR models (low rates of false positive and false negative answers and acceptable results of empirical cross entropy approach). In order to verify whether objective magnification described by its numerical aperture affects spectra interpretation, three objective magnifications -20×(N.A.=0.4.), 50×(N.A.=0.75) and 100×(N.A.=0.85) within each of the applied laser sources (514.5nm and 785nm) were tested for a group of blue solid and metallic automotive paints having the same sets of pigments depending on the applied laser source. The findings obtained by two types of LR models indicate the importance of this parameter for solving the comparison problem of both solid and metallic automotive paints regardless of the laser source used for measuring Raman signal. Hence, the same objective magnification, preferably 50× (established based on the analysis of within- and between-samples variability and F-factor value), should be used when focusing the laser on samples during Raman measurements. Then the influence of parameters (laser power and time of irradiation) of one of the recommended fluorescence suppression techniques, namely photobleaching, was under investigation. Analysis performed on a group of solid automotive paint samples showed that time of irradiation upon established laser power does not affect solving the comparison problem with the use of LR test. Likewise upon established time of irradiation 5% or 10% laser power could be used interchangeably without changing conclusions within this problem. However, upon the established time of irradiation changes in laser power between control and recovered sample from 5% or 10% to 50% may cause erroneous conclusions. Additionally it was also proved that prolonged irradiation of paint does not quantitatively affect pigments bands areas revealed after such a pre-treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Transmission geometry laser ablation into a non-contact liquid vortex capture probe for mass spectrometry imaging.

    PubMed

    Ovchinnikova, Olga S; Bhandari, Deepak; Lorenz, Matthias; Van Berkel, Gary J

    2014-08-15

    Capture of material from a laser ablation plume into a continuous flow stream of solvent provides the means for uninterrupted sampling, transport and ionization of collected material for coupling with mass spectral analysis. Reported here is the use of vertically aligned transmission geometry laser ablation in combination with a new non-contact liquid vortex capture probe coupled with electrospray ionization for spot sampling and chemical imaging with mass spectrometry. A vertically aligned continuous flow liquid vortex capture probe was positioned directly underneath a sample surface in a transmission geometry laser ablation (355 nm, 10 Hz, 7 ns pulse width) set up to capture into solution the ablated material. The outlet of the vortex probe was coupled to the Turbo V™ ion source of an AB SCIEX TripleTOF 5600+ mass spectrometer. System operation and performance metrics were tested using inked patterns and thin tissue sections. Glass slides and slides designed especially for laser capture microdissection, viz., DIRECTOR(®) slides and PEN 1.0 (polyethylene naphthalate) membrane slides, were used as sample substrates. The estimated capture efficiency of laser-ablated material was 24%, which was enabled by the use of a probe with large liquid surface area (~2.8 mm(2) ) and with gravity to help direct ablated material vertically down towards the probe. The swirling vortex action of the liquid surface potentially enhanced capture and dissolution not only of particulates, but also of gaseous products of the laser ablation. The use of DIRECTOR(®) slides and PEN 1.0 (polyethylene naphthalate) membrane slides as sample substrates enabled effective ablation of a wide range of sample types (basic blue 7, polypropylene glycol, insulin and cyctochrome c) without photodamage using a UV laser. Imaging resolution of about 6 µm was demonstrated for stamped ink on DIRECTOR(®) slides based on the ability to distinguish features present both in the optical and in the chemical image. This imaging resolution was 20 times better than the previous best reported results with laser ablation/liquid sample capture mass spectrometry imaging. Using thin sections of brain tissue the chemical image of a selected lipid was obtained with an estimated imaging resolution of about 50 µm. A vertically aligned, transmission geometry laser ablation liquid vortex capture probe, electrospray ionization mass spectrometry system provides an effective means for spatially resolved spot sampling and imaging with mass spectrometry. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.

  6. Submillikelvin Dipolar Molecules in a Radio-Frequency Magneto-Optical Trap.

    PubMed

    Norrgard, E B; McCarron, D J; Steinecker, M H; Tarbutt, M R; DeMille, D

    2016-02-12

    We demonstrate a scheme for magneto-optically trapping strontium monofluoride (SrF) molecules at temperatures one order of magnitude lower and phase space densities 3 orders of magnitude higher than obtained previously with laser-cooled molecules. In our trap, optical dark states are destabilized by rapidly and synchronously reversing the trapping laser polarizations and the applied magnetic field gradient. The number of molecules and trap lifetime are also significantly improved from previous work by loading the trap with high laser power and then reducing the power for long-term trapping. With this procedure, temperatures as low as 400  μK are achieved.

  7. Compact, Passively Q-Switched Nd:YAG Laser for the MESSENGER Mission to the Planet Mercury

    NASA Technical Reports Server (NTRS)

    Krebs, Danny J.; Novo-Gradac, Anne-Marie; Li, Steven X.; Lindauer, Steven J.; Afzal, Robert S.; Yu, Antony

    2004-01-01

    A compact, passively Q-switched Nd:YAG laser has been developed for the Mercury Laser Altimeter (MLA) instrument which is an instrument on the MESSENGER mission to the planet Mercury. The laser achieves 5.4 percent efficiency with a near diffraction limited beam. It has passed all space flight environmental tests at system, instrument, and satellite integration. The laser design draws on a heritage of previous laser altimetry missions, specifically ISESAT and Mars Global Surveyor; but incorporates thermal management features unique to the requirements of an orbit of the planet Mercury.

  8. Potential converter for laser-power beaming

    NASA Technical Reports Server (NTRS)

    Walker, Gilbert H.; Williams, Michael D.; Schuster, Gregory L.; Iles, Peter A.

    1991-01-01

    Future space missions, such as those associated with the Space Exploration Initiative (SEI), will require large amounts of power for operation of bases, rovers, and orbit transfer vehicles. One method for supplying this power is to beam power from a spaced based or Earth based laser power station to a receiver where laser photons can be converted to electricity. Previous research has described such laser power stations orbiting the Moon and beaming power to a receiver on the surface of the Moon by using arrays of diode lasers. Photovoltaic converters that can be efficiently used with these diode lasers are described.

  9. Lasers, Understanding the Atom Series.

    ERIC Educational Resources Information Center

    Hellman, Hal

    This booklet is one of the booklets in the "Understanding the Atom Series" published by the U. S. Atomic Energy Commission for high school science teachers and their students. Basic information for understanding the laser is provided including discussion of the electromagnetic spectrum, radio waves, light and the atom, coherent light, controlled…

  10. Evolution of laser skin resurfacing: from scanning to fractional technology.

    PubMed

    Aslam, Arif; Alster, Tina S

    2014-11-01

    Laser skin resurfacing was popularized for photoaged and scarred skin 2 decades ago. Since then, several technologic advancements have led to a new generation of delivery systems that produce excellent clinical outcomes with reduced treatment risks and faster recovery times. To review the evolution of laser skin resurfacing from pulsed and scanned infrared laser technology to the latest techniques of nonablative and ablative fractional photothermolysis. All published literature regarding laser skin resurfacing was analyzed and collated. A comprehensive review of laser skin resurfacing was outlined and future developments in the field of fractionated laser skin treatment were introduced. Laser skin resurfacing has evolved such that excellent clinical outcomes in photodamaged and scarred skin are achieved with rapid wound healing. As newer devices are developed, the applications of this technology will have a dramatic effect on the delivery of medical and aesthetic dermatology.

  11. Guideline Implementation: Energy-Generating Devices, Part 2-Lasers.

    PubMed

    Burlingame, Byron L

    2017-04-01

    Lasers have been used in the OR for many years and are essential tools in many different types of procedures. However, laser beams that come into contact with unintended targets directly or via reflection can cause injury to patients or personnel or pose other hazards, such as fires. The new AORN "Guideline for safe use of energy-generating devices" provides guidance on the use of all energy-generating devices in the OR. This article focuses on key points of the guideline that address the safe use of lasers. These include the components of the laser safety program, the responsibilities of the personnel in roles specific to use of a laser, laser safety measures, and documentation of laser use. Perioperative RNs should review the complete guideline for additional information and for guidance when writing and updating policies and procedures. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  12. Predictors of femtosecond laser intrastromal astigmatic keratotomy efficacy for astigmatism management in cataract surgery.

    PubMed

    Day, Alexander C; Stevens, Julian D

    2016-02-01

    To evaluate the factors associated with the efficacy of femtosecond laser intrastromal astigmatic keratotomy (AK). Moorfields Eye Hospital, London, United Kingdom. Prospective case series. Eyes having intrastromal AK for corneal cylinder correction were analyzed. Preoperative biometric parameters included axial length, anterior chamber depth, central corneal thickness, and Ocular Response Analyzer corneal hysteresis (CH) and corneal resistance factor (CRF). Preoperative and 1-month postoperative corneal keratometry was measured using the Topcon KR8100PA topographer-autorefractor. Astigmatic analyses were performed using the Alpins method. The study analyzed 319 eyes of 213 patients with a mean target induced astigmatism of 1.24 diopters (D) ± 0.44 (SD), mean surgically induced astigmatism (SIA) of 0.71 ± 0.43 D, and mean difference vector of 0.79 ± 0.41 D. Two multiple regression models were constructed for SIA prediction. Model 1, based on previous manual limbal relaxing incision parameters, confirmed age and astigmatism meridian (with/against the rule and oblique) to be associated with SIA in addition to AK arc length, AK start depth, and preoperative corneal cylinder magnitude. Model 2, additionally considering other parameters, found only lower CH (-0.06 DC per unit CH), a higher CRF (0.04 D per unit CRF), and the astigmatism meridian to be independent predictors of greater SIA (after adjusting for intrastromal AK arc length, start depth, and preoperative corneal cylinder). With-the-rule astigmatism was associated with a 0.13 D higher SIA than against-the-rule astigmatism, holding all other variables constant. Corneal biomechanical parameters and astigmatism meridian were independent predictors of femtosecond laser intrastromal AK efficacy even after adjusting for AK arc length, AK start depth, and preoperative corneal cylinder. Dr. Stevens is a previous consultant to Optimedica, Inc. which is now part of Abbott Medical Optics, Inc. Drs. Stevens and Day have no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. The learning curve, interobserver, and intraobserver agreement of endoscopic confocal laser endomicroscopy in the assessment of mucosal barrier defects.

    PubMed

    Chang, Jeff; Ip, Matthew; Yang, Michael; Wong, Brendon; Power, Theresa; Lin, Lisa; Xuan, Wei; Phan, Tri Giang; Leong, Rupert W

    2016-04-01

    Confocal laser endomicroscopy can dynamically assess intestinal mucosal barrier defects and increased intestinal permeability (IP). These are functional features that do not have corresponding appearance on histopathology. As such, previous pathology training may not be beneficial in learning these dynamic features. This study aims to evaluate the diagnostic accuracy, learning curve, inter- and intraobserver agreement for identifying features of increased IP in experienced and inexperienced analysts and pathologists. A total of 180 endoscopic confocal laser endomicroscopy (Pentax EC-3870FK; Pentax, Tokyo, Japan) images of the terminal ileum, subdivided into 6 sets of 30 were evaluated by 6 experienced analysts, 13 inexperienced analysts, and 2 pathologists, after a 30-minute teaching session. Cell-junction enhancement, fluorescein leak, and cell dropout were used to represent increased IP and were either present or absent in each image. For each image, the diagnostic accuracy, confidence, and quality were assessed. Diagnostic accuracy was significantly higher for experienced analysts compared with inexperienced analysts from the first set (96.7% vs 83.1%, P < .001) to the third set (95% vs 89.7, P = .127). No differences in accuracy were noted between inexperienced analysts and pathologists. Confidence (odds ratio, 8.71; 95% confidence interval, 5.58-13.57) and good image quality (odds ratio, 1.58; 95% confidence interval, 1.22-2.03) were associated with improved interpretation. Interobserver agreement κ values were high and improved with experience (experienced analysts, 0.83; inexperienced analysts, 0.73; and pathologists, 0.62). Intraobserver agreement was >0.86 for experienced observers. Features representative of increased IP can be rapidly learned with high inter- and intraobserver agreement. Confidence and image quality were significant predictors of accurate interpretation. Previous pathology training did not have an effect on learning. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  14. Generalized sub-Schawlow-Townes laser linewidths via material dispersion

    NASA Astrophysics Data System (ADS)

    Pillay, Jason Cornelius; Natsume, Yuki; Stone, A. Douglas; Chong, Y. D.

    2014-03-01

    A recent S-matrix-based theory of the quantum-limited linewidth, which is applicable to general lasers, including spatially nonuniform laser cavities operating above threshold, is analyzed in various limits. For broadband gain, a simple interpretation of the Petermann and bad-cavity factors is presented in terms of geometric relations between the zeros and poles of the S matrix. When there is substantial dispersion, on the frequency scale of the cavity lifetime, the theory yields a generalization of the bad-cavity factor, which was previously derived for spatially uniform one-dimensional lasers. This effect can lead to sub-Schawlow-Townes linewidths in lasers with very narrow gain widths. We derive a formula for the linewidth in terms of the lasing mode functions, which has accuracy comparable to the previous formula involving the residue of the lasing pole. These results for the quantum-limited linewidth are valid even in the regime of strong line pulling and spatial hole burning, where the linewidth cannot be factorized into independent Petermann and bad-cavity factors.

  15. Evaluation of six holmium:YAG optical fibers for ureteroscopy: What's new in 2009?

    NASA Astrophysics Data System (ADS)

    Knudsen, Bodo E.; Teichman, Joel M. H.

    2010-02-01

    The holmium:yttrium aluminum garnet (YAG) laser is the gold standard laser for intracorporeal lithotripsy.1 Optical fibers are utilized to transmit laser energy to the surface of a stone for fragmentation via a predominant photothermal mechanism.2 Previous work has demonstrated that performance characteristics of holmium:YAG optical fibers used for laser lithotripsy varies. Performance may difference not only between fibers made by different manufacturers but also between individual fibers produced by the same manufacturer.3,4 Fiber failure with bending, such as during lower pole ureterorenoscopy, can lead to catastrophic endoscope damage resulting in costly repair. Manufacturers continue to develop new holmium:YAG optical fibers. In this study we evaluate a series of newly commercially available fibers using a previously designed testing protocol. This study was designed to determine the performance and threshold for failure of six newly available holmium:YAG laser fibers from Cook Medical and Fibertech Gmbh. We hypothesize that fiber performance will continue to vary amongst different holmium:YAG optical fibers.

  16. Experimental scaling law for mass ablation rate from a Sn plasma generated by a 1064 nm laser

    NASA Astrophysics Data System (ADS)

    Burdt, Russell A.; Yuspeh, Sam; Sequoia, Kevin L.; Tao, Yezheng; Tillack, Mark S.; Najmabadi, Farrokh

    2009-08-01

    The ablation depth in planar Sn targets irradiated with a pulsed 1064 nm laser was investigated over laser intensities from 3×1011 to 2×1012 W/cm2. The ablation depth was measured by irradiating a thin layer of Sn evaporated onto a Si wafer, and looking for signatures of Si ions in the expanding plasma with spectroscopic and particle diagnostics. It was found that ablation depth scales with laser intensity to the (5/9)th power, which is consistent with analytical models of steady-state laser ablation, as well as empirical formulae from previous studies of mass ablation rate in overlapping parameter space. In addition, the scaling of mass ablation rate with atomic number of the target as given by empirical formulae in previous studies using targets such as C and Al, are shown to remain valid for the higher atomic number of the target (Z =50) used in these experiments.

  17. Thulium fiber laser damage to the ureter

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher R.; Hardy, Luke A.; Irby, Pierce B.; Fried, Nathaniel M.

    2015-07-01

    Our laboratory is studying experimental thulium fiber laser (TFL) as a potential alternative lithotripter to the clinical gold standard Holmium:YAG laser. Safety studies characterizing undesirable Holmium laser-induced damage to ureter tissue have been previously reported. Similarly, this study characterizes TFL induced ureter and stone basket damage. A TFL beam with pulse energy of 35 mJ, pulse duration of 500 μs, and pulse rates of 150-500 Hz was delivered through a 100-μm-core, low-OH, silica optical fiber to the porcine ureter wall, in vitro. Ureter perforation times were measured and gross, histological, and optical coherence tomography images of the ablation zone were acquired. TFL operation at 150, 300, and 500 Hz produced mean ureter perforation times of 7.9, 3.8, and 1.8 s, respectively. Collateral damage averaged 510, 370, and 310 μm. TFL mean perforation time exceeded 1 s at each setting, which is a greater safety margin than previously reported during Holmium laser ureter perforation studies.

  18. Quantum Phenomena in High Energy Density Plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murnane, Margaret; Kapteyn, Henry

    The possibility of implementing efficient (phase matched) HHG upconversion of deep- UV lasers in multiply-ionized plasmas, with potentially unprecedented conversion efficiency is a fascinating prospect. HHG results from the extreme nonlinear response of matter to intense laser light:high harmonics are radiated as a result of a quantum coherent electron recollision process that occurs during laser field ionization of an atom. Under current support from this grant in work published in Science in 2015, we discovered a new regime of bright HHG in highly-ionized plasmas driven by intense UV lasers, that generates bright harmonics to photon energies >280eV

  19. DNA-based dye lasers: progress in this half a decade

    NASA Astrophysics Data System (ADS)

    Kawabe, Yutaka

    2016-09-01

    After the invention of DNA-surfactant films and the proposal of dye doping into them by Ogata, many applications were demonstrated. Among them tunable thin film laser is one of the most attractive functional devices. Development and progress in DNA based lasers after the first observation of amplified spontaneous emission (ASE) by us has been reviewed in a former paper published in 2011.1 In this proceeding, progresses in the subsequent half a decade are described.

  20. Efficacy of Erbium:YAG laser treatment compared to topical estriol treatment for symptoms of genitourinary syndrome of menopause.

    PubMed

    Gaspar, Adrian; Brandi, Hugo; Gomez, Valentin; Luque, Daniel

    2017-02-01

    The objective of this prospective comparative cohort study was to establish the effectiveness and safety of Erbium:YAG (Er:YAG) laser treatment for genitourinary syndrome of menopause and to compare it with an established topical estriol treatment. Fifty patients with genitourinary syndrome of menopause were divided into two groups. The estriol group received a treatment of 0.5 mg estriol ovules for 8 weeks and the laser group was first treated for 2 weeks with 0.5 mg estriol ovules 3 times per week to hydrate the mucosa and then received three sessions with 2,940 nm Er:YAG laser in non-ablative mode. Biopsies were taken before and at 1, 3, 6, and 12 months post-treatment. Maturation index, maturation value and pH where recorded up to 12-months post-treatment, while the VAS analysis of symptoms was recorded up to 18 months post-treatment. Statistically significant (P < 0.05), reduction of all assessed symptoms was observed in the laser group at all follow-ups up to 18 months post-treatment. Significant improvement in maturation value and a decrease of pH in the laser group was detected up to 12 months after treatment. The improvement in all endpoints was more pronounced and longer lasting in the laser group. Histological examination showed changes in the tropism of the vaginal mucosa and also angiogenesis, congestion, and restructuring of the lamina propria in the laser group. Side effects were minimal and of transient nature in both groups, affecting 4% of patients in the laser group and 12% of patients in the estriol group. Our results show that Er:YAG laser treatment successfully relieves symptoms of genitourinary syndrome of menopause and that the results are more pronounced and longer lasting compared to topical estriol treatment. Lasers Surg. Med. 49:160-168, 2017. © 2016 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. © 2016 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

  1. International laser-safety regulations: a status update

    NASA Astrophysics Data System (ADS)

    Weiner, Robert M.

    1990-07-01

    There is an increase in international laser safety requirements as part of the emphasis on world-wide standardization of products and regulations. In particular the documents which will evolve from the 1992 consolidation efforts of the European Community (EC) will impact both laser manufacturers and users. This paper provides a discussion of the current status of the various laser radiation standards. NORTH AMERICAN REQUIREMENTS United States Requirements on manufacturers from the Food and Drug Administration (FDA) have been in effect since 1975. The Center for Devices and Radiological Health (CDRH) within that agency ensures that these mandatory requirements [1] are satisfied. The CDRH regulations include the division of products into classes depending on their potential for hazard criteria for power measurement and requirements for product features labels and manuals and records and reports. Manufacturers must test products and certify that they comply with the CDRH requirements. User requirements are found in a standard published by the American National Standards Institute (ANSI) and in requirements from several individual states. Specific ANSI standards have also been published for fiber communications systems [34] and for lasers in medical applications [35]. Please note that the Appendix includes additional information on the standards discussed in this paper including sources for obtaining the documents. Canada In the past Canada has had requirements for two specified product categories (bar code scanners and educational lasers) [26 These will be replaced

  2. Current role of cryotherapy in retinopathy of prematurity: a report by the American Academy of Ophthalmology.

    PubMed

    Simpson, Jennifer L; Melia, Michele; Yang, Michael B; Buffenn, Angela N; Chiang, Michael F; Lambert, Scott R

    2012-04-01

    To evaluate the role of cryotherapy in the current treatment of retinopathy of prematurity (ROP). Literature searches of PubMed and the Cochrane Library were conducted on December 2, 2009, for articles published after 1984. The searches included all languages and retrieved 187 relevant citations. Thirteen articles were deemed relevant to the assessment question and were rated according to the strength of evidence. Four articles reported results from 2 large multicenter randomized clinical trials, and the remaining 9 articles reported results of 3 small randomized trials that directly compared cryotherapy and laser. Neither of the multicenter randomized clinical trials was a direct comparison of cryotherapy with laser. These studies were used to evaluate the comparative trials based on treatment criteria, study populations, and clinical results. Higher percentages of poor structural and functional outcomes generally were seen in eyes treated with cryotherapy compared with eyes undergoing laser treatment. Higher rates of systemic complications and myopia also were identified after treatment with cryotherapy. Despite a relative paucity of level I evidence directly comparing cryotherapy and laser treatment for threshold ROP, the literature suggests that neonatal facilities should gain access to laser technology and laser-trained ophthalmic staff to achieve better outcomes for treatment of the disease. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. Reduction of protection from laser eyewear with ultrashort exposure

    NASA Astrophysics Data System (ADS)

    Stolarski, David J.; Stolarski, Jacob; Noojin, Gary D.; Rockwell, Benjamin A.; Thomas, Robert J.

    2001-07-01

    We have measured the optical density of various laser eye protection samples as a function of increasing irradiance. We show that the protective quality of some eyewear degrades as irradiance increases. In previous studies this problem has been demonstrated in samples irradiated by nanosecond pulses, but the current study shows that the modern laser eye protection seems to be robust except for the irradiance possible with ultrashort laser pulse exposure. We discuss the most likely saturation mechanisms in this pulse duration regime and discuss relevance to laser safety.

  4. Development of Technologies to Utilize Laser Plasma Radiations Sources for Radiation Effects Sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, J F

    2007-01-31

    This final report will cover work performed over the period of November 11, 2005 to September 30, 2006 on the contract to develop technologies using laser sources for radiation effects sciences. The report will discuss four topic areas; the laser source experiments on the Gekko Laser at Osaka, Japan, planning for the Charge State Freeze Out experiments to be performed in calendar year 2007, a review of previous xenon gasbags on the LANL Trident laser to provide planning support to the May-June 2007 HELEN experiments.

  5. Laser-fluorescence measurement of marine algae

    NASA Technical Reports Server (NTRS)

    Browell, E. V.

    1980-01-01

    Progress in remote sensing of algae by laser-induced fluorescence is subject of comprehensive report. Existing single-wavelength and four-wavelength systems are reviewed, and new expression for power received by airborne sensor is derived. Result differs by as much as factor of 10 from those previously reported. Detailed error analysis evluates factors affecting accuracy of laser-fluorosensor systems.

  6. Immediate and long-term changes of fundus autofluorescence in continuous wave laser lesions of the retina.

    PubMed

    Framme, Carsten; Roider, Johann

    2004-01-01

    To determine whether fundus autofluorescence imaging is able to show changes in retinal pigment epithelium (RPE) fluorescence after thermal laser photocoagulation. In vivo imaging of fundus autofluorescence was performed with a scanning laser ophthalmoscope. A laser with a wavelength of 488 nm was used for excitation of the tissue and autofluorescence was detected above 500 nm using a barrier filter. One hundred eight eyes of 87 patients who had had previous laser treatment were monitored. The appearance and size of the laser lesions were documented and correlated to the time of treatment. Immediate changes were observed prospectively in 13 eyes; long-term follow-up was studied retrospectively in 95 eyes. In all patients but one, autofluorescence was decreased in the area of laser lesions 1 hour after laser treatment. After 1 month, previously decreased autofluorescence in all lesions changed to significantly increased autofluorescence, which was stable up to 6 months after treatment. Mixed forms were present approximately 6 to 12 months after treatment, showing a central island of increased autofluorescence surrounded by a ring of decreased autofluorescence. After 1 to 2 years, lesions again changed to complete dark spots, enlarging later on. RPE destruction and subsequent proliferation after continuous wave laser photocoagulation can be visualized noninvasively by autofluorescence imaging. Immediate decreased autofluorescence may indicate acute damage of the RPE, subsequent increased autofluorescence seems to indicate proliferative behavior of the RPE, and final dark spots can indicate RPE atrophy secondary to a denaturation of neurosensory retinal tissue. Thus, autofluorescence can be used in the long-term monitoring of RPE changes after laser treatment. The enlargement of the laser atrophy zone demonstrates the potential risk of visual loss after central laser photocoagulation even years after treatment.

  7. Low-power laser effects in equine traumatology and postsurgically

    NASA Astrophysics Data System (ADS)

    Antikas, Theo G.

    1991-05-01

    The present field study on 800 cases of LPL treatments in situ using a preset `blind code' was designed to verify previously published field results; and to check whether a practicing equine vet, trainer, horse owner or rider may obtain beneficial therapeutic effects in traumatology and/or post-surgery, two of the most prevailing modalities in equine sportsmedicine. With the exception of chronic infected traumas, the positive/beneficial response to LPL treatment was verified in a range of 33.3% (infected) to 100% (non-infected, surgical) of the traumas under investigation. The administration of antibiotics, a modality compatible with LPL treatment in infected injuries, increased the beneficial effects of LPL irradiation to 66.7%. This fact indicates that laser irradiation should not be considered a replacement of common therapeutic routine but simply an efficient follow up or parallel treatment that may act synergistically to the benefit of an injured equine athlete. In the case of non-infected surgical trauma, LPL-treatment was additionally found to shorten the post-surgical `inactive' time period or `comeback time' (CBT), thus bringing the horse back into its sportive capacity considerably faster than without LPL irradiation, and at a statistically significant level (p < 0.001).

  8. Coupled electric fields in photorefractive driven liquid crystal hybrid cells - theory and numerical simulation

    NASA Astrophysics Data System (ADS)

    Moszczyński, P.; Walczak, A.; Marciniak, P.

    2016-12-01

    In cyclic articles previously published we described and analysed self-organized light fibres inside a liquid crystalline (LC) cell contained photosensitive polymer (PP) layer. Such asymmetric LC cell we call a hybrid LC cell. Light fibre arises along a laser beam path directed in plane of an LC cell. It means that a laser beam is parallel to photosensitive layer. We observed the asymmetric LC cell response on an external driving field polarization. Observation has been done for an AC field first. It is the reason we decided to carry out a detailed research for a DC driving field to obtain an LC cell response step by step. The properly prepared LC cell has been built with an isolating layer and garbage ions deletion. We proved by means of a physical model, as well as a numerical simulation that LC asymmetric response strongly depends on junction barriers between PP and LC layers. New parametric model for a junction barrier on PP/LC boundary has been proposed. Such model is very useful because of lack of proper conductivity and charge carriers of band structure data on LC material.

  9. Applications of the Excimer Laser: A Review.

    PubMed

    Beggs, Sarah; Short, Jack; Rengifo-Pardo, Monica; Ehrlich, Alison

    2015-11-01

    The 308-nm excimer laser has been approved by the Food and Drug Administration for the treatment of psoriasis and vitiligo. Its ability to treat localized areas has led to many studies determining its potential in the treatment of focal diseases with inflammation or hypopigmentation. To review the different applications of the 308-nm excimer laser for treating dermatologic conditions. An extensive literature review was conducted by searching PubMed, MEDLINE, and ClinicalKey to find articles pertaining to dermatologic conditions treated with the 308-nm excimer laser. Articles published that contributed to new applications of the excimer laser were included, as well as initial studies utilizing the excimer laser. The outcomes and results were compiled for different dermatologic conditions treated with the excimer laser. The 308-nm excimer laser has a wide range of uses for focal inflammatory and hypopigmented conditions. Treatment is generally well tolerated, with few adverse reactions. Larger studies and studies evaluating the long-term effects of the 308-nm excimer laser are needed.

  10. Implementing AORN Recommended Practices for Laser Safety.

    PubMed

    Castelluccio, Donna

    2012-05-01

    Lasers used in the OR pose many risks to both patients and personnel. AORN's "Recommended practices for laser safety in perioperative practice settings" identifies the potential hazards associated with laser use, such as eye damage and fire- and smoke-related injuries. The practice recommendations are intended to be used as a guide for establishing best practices in the workplace and to give perioperative nurses strategies for implementing the recommended safety measures. A laser safety program should include measures to control access to laser use areas; protect staff members and patients from exposure to the laser beam; provide staff members and patients with the appropriate safety eyewear for use in the laser use area; and protect staff members and patients from surgical smoke, electrical, and fire hazards. Measures such as using a safety checklist or creating a laser cart can help perioperative nurses successfully incorporate the practice recommendations. Patient scenarios are included as examples of how to use the document in real-life situations. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  11. Topography-Guided PRK and Crosslinking in Eyes with Keratoconus and Post-LASIK Ectasia.

    PubMed

    Müller, T M; Lange, A P

    2017-04-01

    Topography-guided photorefractive keratectomy (TG-PRK) combined with corneal collagen crosslinking (CXL) has been shown to potentially improve vision and stabilize progression in patients with keratoconus (KC). We attempted to reproduce the previously published results using a different laser platform (AMARIS 500E) in patients with KC and post-LASIK ectasia (PLE). All of the 9 included eyes showed improved topography (Kmax, Kmean, RMS HOA, vertical coma, cylinder; p < 0.05) and improved visual acuity (BCVA, UCVA; p < 0.05) after 18 months. Despite some still uncontrollable factors, the combination of TG-PRK and CXL may be a promising option to regularize and stabilize corneas with KC and PLE and improve visual acuity. Georg Thieme Verlag KG Stuttgart · New York.

  12. Statistical behavior of ten million experimental detection limits

    NASA Astrophysics Data System (ADS)

    Voigtman, Edward; Abraham, Kevin T.

    2011-02-01

    Using a lab-constructed laser-excited fluorimeter, together with bootstrapping methodology, the authors have generated many millions of experimental linear calibration curves for the detection of rhodamine 6G tetrafluoroborate in ethanol solutions. The detection limits computed from them are in excellent agreement with both previously published theory and with comprehensive Monte Carlo computer simulations. Currie decision levels and Currie detection limits, each in the theoretical, chemical content domain, were found to be simply scaled reciprocals of the non-centrality parameter of the non-central t distribution that characterizes univariate linear calibration curves that have homoscedastic, additive Gaussian white noise. Accurate and precise estimates of the theoretical, content domain Currie detection limit for the experimental system, with 5% (each) probabilities of false positives and false negatives, are presented.

  13. Biofilm removal by 6% sodium hypochlorite activated by different irrigation techniques.

    PubMed

    Ordinola-Zapata, R; Bramante, C M; Aprecio, R M; Handysides, R; Jaramillo, D E

    2014-07-01

    To compare the removal of biofilm utilizing four irrigation techniques on a bovine root canal model. Fifty dentine specimens (2 × 2 mm) were infected with biofilm. The samples were then adapted to previously created cavities in the bovine model. The root canals were irrigated twice with 2 mL of 6% sodium hypochlorite for 2 min (4 min total). Following initial irrigation, the different treatment modalities were introduced for 60 s (3 × 20 s intervals). The evaluated techniques were needle irrigation, Endoactivator (Dentsply Tulsa Dental, Tulsa, OK, USA), passive ultrasonic irrigation and laser-activated irrigation (photon-induced photoacoustic streaming). The controls were irrigated with distilled water and conventional needle irrigation. Subsequently, the dentine samples were separated from the model and analysed using a scanning electron microscope (SEM). Fifteen operative fields were scanned per block, and SEM pictures were captured. Two calibrated evaluators examined the images and collected data using a four-degree scale. Nonparametric tests were used to evaluate for statistical significance amongst the groups. The group undergoing laser-activated irrigation using photon-induced photoacoustic streaming exhibited the most favourable results in the removal of biofilm. Passive ultrasonic irrigation scores were significantly lower than both the Endoactivator and needle irrigation scores. Sonic and needle irrigation were not significantly different. The least favourable results were found in the control group. Laser activation of 6% sodium hypochlorite significantly improved the cleaning of biofilm-infected dentine followed by passive ultrasonic irrigation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. Desktop Publishing: A New Frontier for Instructional Technologists.

    ERIC Educational Resources Information Center

    Bell, Norman T.; Warner, James W.

    1986-01-01

    Discusses new possibilities that computers and laser printers offer instructional technologists. Includes a brief history of printed communications, a description of new technological advances referred to as "desktop publishing," and suggests the application of this technology to instructional tasks. (TW)

  15. Experimental Investigation of Axial and Beam-Riding Propulsive Physics with TEA CO{sub 2} laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kenoyer, D. A.; Salvador, I.; Myrabo, L. N.

    2010-10-08

    A twin Lumonics K922M pulsed TEA CO{sub 2} laser system (pulse duration of approximately 100 ns FWHM spike, with optional 1 {mu}s tail, depending upon laser gas mix) was employed to experimentally measure both axial thrust and beam-riding behavior of Type no. 200 lightcraft engines, using a ballistic pendulum and Angular Impulse Measurement Device (AIMD, respectively. Beam-riding forces and moments were examined along with engine thrust-vectoring behavior, as a function of: a) laser beam lateral offset from the vehicle axis of symmetry; b) laser pulse energy ({approx}12 to 40 joules); c) pulse duration (100 ns, and 1 {mu}s); and d)more » engine size (97.7 mm to 161.2 mm). Maximum lateral momentum coupling coefficients (C{sub M}) of 75 N-s/MJ were achieved with the K922M laser whereas previous PLVTS laser (420 J, 18 {mu}s duration) results reached only 15 N-s/MJ--an improvement of 5x. Maximum axial C{sub M} performance with the K922M reached 225 N-s/MJ, or about {approx}3x larger than the lateral C{sub M} values. These axial C{sub M} results are sharply higher than the 120 N/MW previously reported for long pulse (e.g., 10-18 {mu}s)CO{sub 2} electric discharge lasers.« less

  16. Retrieval of the 1964 Laser Literature Using MIT's Project Tip.

    ERIC Educational Resources Information Center

    Keenan, Stella; Terry, Edward

    Reported are the performance characteristics of the Massachusetts Institute of Technology Technical Information Program (TIP) system based on a study involving three search strategies in retrieval o f laser articles published in 1964. The TIP system provides access to (1) title, (2) author(s), (3) bibliographic references, and (4) literature…

  17. Rationale for the diabetic retinopathy clinical research network treatment protocol for center-involved diabetic macular edema.

    PubMed

    Aiello, Lloyd Paul; Beck, Roy W; Bressler, Neil M; Browning, David J; Chalam, K V; Davis, Matthew; Ferris, Frederick L; Glassman, Adam R; Maturi, Raj K; Stockdale, Cynthia R; Topping, Trexler M

    2011-12-01

    To describe the underlying principles used to develop a web-based algorithm that incorporated intravitreal anti-vascular endothelial growth factor (anti-VEGF) treatment for diabetic macular edema (DME) in a Diabetic Retinopathy Clinical Research Network (DRCR.net) randomized clinical trial. Discussion of treatment protocol for DME. Subjects with vision loss resulting from DME involving the center of the macula. The DRCR.net created an algorithm incorporating anti-VEGF injections in a comparative effectiveness randomized clinical trial evaluating intravitreal ranibizumab with prompt or deferred (≥24 weeks) focal/grid laser treatment in eyes with vision loss resulting from center-involved DME. Results confirmed that intravitreal ranibizumab with prompt or deferred laser provides superior visual acuity outcomes compared with prompt laser alone through at least 2 years. Duplication of this algorithm may not be practical for clinical practice. To share their opinion on how ophthalmologists might emulate the study protocol, participating DRCR.net investigators developed guidelines based on the algorithm's underlying rationale. Clinical guidelines based on a DRCR.net protocol. The treatment protocol required real-time feedback from a web-based data entry system for intravitreal injections, focal/grid laser treatment, and follow-up intervals. Guidance from this system indicated whether treatment was required or given at investigator discretion and when follow-up should be scheduled. Clinical treatment guidelines, based on the underlying clinical rationale of the DRCR.net protocol, include repeating treatment monthly as long as there is improvement in edema compared with the previous month or until the retina is no longer thickened. If thickening recurs or worsens after discontinuing treatment, treatment is resumed. Duplication of the approach used in the DRCR.net randomized clinical trial to treat DME involving the center of the macula with intravitreal ranibizumab may not be practical in clinical practice, but likely can be emulated based on an understanding of the underlying rationale for the study protocol. Inherent differences between a web-based treatment algorithm and a clinical approach may lead to differences in outcomes that are impossible to predict. The closer the clinical approach is to the algorithm used in the study, the more likely the outcomes will be similar to those published. Proprietary or commercial disclosure may be found after the references. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Subthreshold micropulse laser reduces anti-VEGF injection burden in patients with diabetic macular edema.

    PubMed

    Moisseiev, Elad; Abbassi, Sam; Thinda, Sumeer; Yoon, Joseph; Yiu, Glenn; Morse, Lawrence S

    2018-01-01

    To evaluate the efficacy of micropulse laser in the early treatment of diabetic macular edema (DME) and its associated burden of anti-vascular endothelial growth factor (VEGF) injections. This retrospective comparative study compared a group of 19 eyes with DME treated with micropulse laser to a matched control group of 19 eyes with DME treated with ranibizumab injections without micropulse laser. Recorded parameters included previous medical and ocular history, previous and subsequent ranibizumab injections administered for DME, visual acuity (VA), central macular thickness throughout the follow-up period, and the occurrence of any complications. The improvement in VA was comparable in both groups, at 12 months and at the final follow-up. Patients treated with micropulse laser required significantly fewer ranibizumab injections than their controls, both at 12 months (1.7 ± 2.3 vs 5.6 ± 2.1) and by the end of the follow-up (2.6 ± 3.3 vs 9.3 ± 5.1) (p<0.001 for both). No complications related to the micropulse laser were encountered. Micropulse laser is a safe and effective treatment for DME, which may achieve comparable improvement in VA along with a significant reduction in the burden of anti-VEGF injections. We suggest a treatment approach for its inclusion in the early stages of DME.

  19. International Comparison of Methane-Stabilized He-Ne Lasers

    NASA Astrophysics Data System (ADS)

    Koshelyaevskii, N. B.; Oboukhov, A.; Tatarenkov, V. M.; Titov, A. N.; Chartier, J.-M.; Felder, R.

    1981-01-01

    Two portable methane-stabilized lasers designed at BIPM have been compared with a type a stationary Soviet device developed in VNIIFTRI1. This comparison is one of a series aimed at establishing the coherence of laser wavelength and frequency measurements throughout the world and took place in June 1979. The VNIIFTRI and BIPM lasers using different methods of stabilization, have different optical and mechanical designs and laser tubes. The results of previous measurements, made in VNIIFTRI, of the most important frequency shifts for Soviet lasers together with a method of reproducing their frequency which leads to a precision of 1.10-12 are also presented.

  20. Laser balancing system for high material removal rates

    NASA Technical Reports Server (NTRS)

    Jones, M. G.; Georgalas, G.; Ortiz, A. L.

    1984-01-01

    A laser technique to remove material in excess of 10 mg/sec from a spinning rotor is described. This material removal rate is 20 times greater than previously reported for a surface speed of 30 m/sec. Material removal enhancement was achieved by steering a focused laser beam with moving optics to increase the time of laser energy interaction with a particular location on the circumferential surface of a spinning rotor. A neodymium:yttrium aluminum garnet (Nd:YAG) pulse laser was used in this work to evaluate material removal for carbon steel, 347 stainless steel, Inconal 718, and titanium 6-4. This technique is applicable to dynamic laser balancing.

  1. Lateral modes of broad area semiconductor lasers - Theory and experiment

    NASA Technical Reports Server (NTRS)

    Lang, Robert J.; Larsson, Anders G.; Cody, Jeffrey G.

    1991-01-01

    Calculations of the lateral modes of an ideal broad area laser, including the nonlinear interaction between the carriers and the optical field, are made. The results include periodically modulated near fields and single- and double-lobed far fields similar to those previously measured. The unsaturable losses are higher and quantum efficiencies are lower than those determined from plane-wave approximations. Broad area InGaAs-GaAlAs-GaAs quantum-well lasers were fabricated and measured and found to closely agree with the theory in near, far, and spectrally resolved near fields. An occultation experiment on the far field confirms previously predicted unstable resonatorlike modes with V-shaped fronts.

  2. Light and Laser Modalities in the Treatment of Cutaneous Sarcoidosis: A Systematic Review.

    PubMed

    Lima, Ana Luiza; Goetze, Steven; Illing, Tanja; Elsner, Peter

    2018-04-27

    Sarcoidosis is a systemic non-caseating granulomatous disease of unknown aetiology. Cutaneous manifestations are present in approximately 10-30% of the patients with the systemic form. Therapy is indicated in case of disabling symptoms, organ dysfunction or cosmetically distressing manifestation. Despite different therapeutic possibilities, cutaneous sarcoidosis remains exceptionally difficult to treat. Light and laser therapy may be a promising alternative. In this systematic review, we summarised the available treatments according to the literature concerning light and laser therapy for cutaneous sarcoidosis. Publications written in English and German, published between January 1990 and July 2016 in the database PubMed, MEDLINE, Embase, and Scopus were analysed. Light therapy with intense pulsed light, photodynamic therapy, and ultraviolet A light therapy, as well as laser therapy with pulsed dye laser, YAG laser, and Q-switched ruby laser were described. The results are based on individual case reports and small case series. Randomised controlled studies are lacking.

  3. Propagation of 3-D Beams Using a Finite-Difference Algorithm: Practical Considerations

    DTIC Science & Technology

    2011-05-22

    electric-discharge laser ,” J. Appl. Phys. 49(3), 1012–1027 (1978). [6] Sziklas, E. A. and Siegman , A. E., “Mode calculations in unstable resonators with...flowing saturable gain .2. fast fourier-transform method,” Applied Optics 14(8), 1874–1889 (1975). [7] Siegman , A. E., [ Lasers ], University Science...Signed// ALAN H. PAXTON, DR-III Project Manager //Signed// MICHAEL F. SHEEHAN, DR-III, DAF Acting Chief, Laser Division This report is published in

  4. Investigation of the Low Power Stage of an 1178 nm Raman System

    DTIC Science & Technology

    2013-12-23

    LEANNE HENRY, DR-III, DAF KENTON T. WOOD, DR-IV, DAF Work Unit Manager Chief, Laser Division This report is published in the...and 1069 nm pumped Raman laser system where the second Stokes is amplified in a 1121 nm resonator defined by high reflector fiber Bragg gratings (FBGs...the gratings was found to impact the performance of the laser and needs to be dealt with in order to obtain high 1178 nm output power levels. In order

  5. Dynamics and control of fast ion crystal splitting in segmented Paul traps (Open Access, Publisher’s Version)

    DTIC Science & Technology

    2014-07-09

    operations, in addition to laser - or microwave-driven logic gates. Essential shuttling operations are splitting and merging of linear ion crystals. It is...from stray charges, laser induced charging of the trap [19], trap geometry imperfections or residual ponderomotive forces along the trap axis. The...transfer expressed as the mean phonon number Δ ω¯ = n E / f . We distinguish several regimes of laser –ion interaction: (i) if the vibrational

  6. Printed Large-Area Single-Mode Photonic Crystal Bandedge Surface-Emitting Lasers on Silicon (Open Access Publisher’s Version)

    DTIC Science & Technology

    2016-01-04

    Mode Photonic Crystal Bandedge Surface-Emitting Lasers on Silicon Article in Scientific Reports · January 2016 DOI : 10.1038/srep18860 CITATIONS 5 READS...1Scientific RepoRts | 6:18860 | DOI : 10.1038/srep18860 www.nature.com/scientificreports Printed Large-Area Single-Mode Photonic Crystal Bandedge...bandgap group III-V materials on Si1,4–11 through wafer bonding, printing, and direct-growth. Most lasers demonstrated so far are edge-emitting

  7. Automated laser guidance of neuronal growth cones using a spatial light modulator.

    PubMed

    Carnegie, David J; Cizmár, Tomás; Baumgartl, Jörg; Gunn-Moore, Frank J; Dholakia, Kishan

    2009-11-01

    The growth cone of a developing neuron can be guided using a focused infra-red (IR) laser beam [1]. In previous setups this process has required a significant amount of user intervention to adjust continuously the laser beam to guide the growing neuron. Previously, a system using an acousto-optical deflector (AOD) has been developed to steer the beam [2]. However, to enhance the controllability of this system, here we demonstrate the use of a computer controlled spatial light modulator (SLM) to steer and manipulate the shape of a laser beam for use in guided neuronal growth. This new experimental setup paves the way to enable a comprehensive investigation into beam shaping effects on neuronal growth and we show neuronal growth initiated by a Bessel light mode. This is a robust platform to explore the biochemistry of this novel phenomenon. (c) 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

  8. Diagnosis of NMOS DRAM functional performance as affected by a picosecond dye laser

    NASA Technical Reports Server (NTRS)

    Kim, Q.; Schwartz, H. R.; Edmonds, L. D.; Zoutendyk, J. A.

    1992-01-01

    A picosec pulsed dye laser beam was at selected wavelengths successfully used to simulate heavy-ion single-event effects (SEEs) in negative channel NMOS DRAMs. A DRAM was used to develop the test technique because bit-mapping capability and previous heavy-ion upset data were available. The present analysis is the first to establish such a correlation between laser and heavy-ion data for devices, such as the NMOS DRAM, where charge collection is dominated by long-range diffusion, which is controlled by carrier density at remote distances from a depletion region. In the latter case, penetration depth is an important parameter and is included in the present analysis. A single-pulse picosecond dye laser beam (1.5 microns diameter) focused onto a single cell component can upset a single memory cell; clusters of memory cell upsets (multiple errors) were observed when the laser energy was increased above the threshold energy. The multiple errors were analyzed as a function of the bias voltage and total energy of a single pulse. A diffusion model to distinguish the multiple upsets from the laser-induced charge agreed well with previously reported heavy ion data.

  9. No effect of femtosecond laser pulses on M13, E. coli, DNA, or protein.

    PubMed

    Wigle, Jeffrey C; Holwitt, Eric A; Estlack, Larry E; Noojin, Gary D; Saunders, Katharine E; Yakovlev, Valdislav V; Rockwell, Benjamin A

    2014-01-01

    Data showing what appears to be nonthermal inactivation of M13 bacteriophage (M13), Tobacco mosaic virus, Escherichia coli (E. coli), and Jurkatt T-cells following exposure to 80-fs pulses of laser radiation have been published. Interest in the mechanism led to attempts to reproduce the results for M13 and E. coli. Bacteriophage plaque-forming and bacteria colony-forming assays showed no inactivation of the microorganisms; therefore, model systems were used to see what, if any, damage might be occurring to biologically important molecules. Purified plasmid DNA (pUC19) and bovine serum albumin were exposed to and analyzed by agarose gel electrophoresis (AGE) and polyacrylamide gel electrophoresis (PAGE), respectively, and no effect was found. DNA and coat proteins extracted from laser-exposed M13 and analyzed by AGE or PAGE found no effect. Raman scattering by M13 in phosphate buffered saline was measured to determine if there was any physical interaction between M13 and femtosecond laser pulses, and none was found. Positive controls for the endpoints measured produced the expected results with the relevant assays. Using the published methods, we were unable to reproduce the inactivation results or to show any interaction between ultrashort laser pulses and buffer/water, DNA, protein, M13 bacteriophage, or E. coli.

  10. No effect of femtosecond laser pulses on M13, E. coli, DNA, or protein

    NASA Astrophysics Data System (ADS)

    Wigle, Jeffrey C.; Holwitt, Eric A.; Estlack, Larry E.; Noojin, Gary D.; Saunders, Katharine E.; Yakovlev, Valdislav V.; Rockwell, Benjamin A.

    2014-01-01

    Data showing what appears to be nonthermal inactivation of M13 bacteriophage (M13), Tobacco mosaic virus, Escherichia coli (E. coli), and Jurkatt T-cells following exposure to 80-fs pulses of laser radiation have been published. Interest in the mechanism led to attempts to reproduce the results for M13 and E. coli. Bacteriophage plaque-forming and bacteria colony-forming assays showed no inactivation of the microorganisms; therefore, model systems were used to see what, if any, damage might be occurring to biologically important molecules. Purified plasmid DNA (pUC19) and bovine serum albumin were exposed to and analyzed by agarose gel electrophoresis (AGE) and polyacrylamide gel electrophoresis (PAGE), respectively, and no effect was found. DNA and coat proteins extracted from laser-exposed M13 and analyzed by AGE or PAGE found no effect. Raman scattering by M13 in phosphate buffered saline was measured to determine if there was any physical interaction between M13 and femtosecond laser pulses, and none was found. Positive controls for the endpoints measured produced the expected results with the relevant assays. Using the published methods, we were unable to reproduce the inactivation results or to show any interaction between ultrashort laser pulses and buffer/water, DNA, protein, M13 bacteriophage, or E. coli.

  11. Application of tissue mesodissection to molecular cancer diagnostics.

    PubMed

    Krizman, David; Adey, Nils; Parry, Robert

    2015-02-01

    To demonstrate clinical application of a mesodissection platform that was developed to combine advantages of laser-based instrumentation with the speed/ease of manual dissection for automated dissection of tissue off standard glass slides. Genomic analysis for KRAS gene mutation was performed on formalin fixed paraffin embedded (FFPE) cancer patient tissue that was dissected using the mesodissection platform. Selected reaction monitoring proteomic analysis for quantitative Her2 protein expression was performed on FFPE patient tumour tissue dissected by a laser-based instrument and the MilliSect instrument. Genomic analysis demonstrates highly confident detection of KRAS mutation specifically in lung cancer cells and not the surrounding benign, non-tumour tissue. Proteomic analysis demonstrates Her2 quantitative protein expression in breast cancer cells dissected manually, by laser-based instrumentation and by MilliSect instrumentation (mesodissection). Slide-mounted tissue dissection is commonly performed using laser-based instruments or manually scraping tissue by scalpel. Here we demonstrate that the mesodissection platform as performed by the MilliSect instrument for tissue dissection is cost-effective; it functions comparably to laser-based dissection and which can be adopted into a clinical diagnostic workflow. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Warm Hearts/Cold Type: Desktop Publishing Arrives.

    ERIC Educational Resources Information Center

    Kramer, Felix

    1991-01-01

    Describes desktop publishing (DTP) that may be suitable for community, activist, and nonprofit groups and discusses how it is changing written communication. Topics discussed include costs; laser printers; time savings; hardware and software selection; and guidelines to consider when establishing DTP capability. (LRW)

  13. Diode laser operating on an atomic transition limited by an isotope ⁸⁷Rb Faraday filter at 780 nm.

    PubMed

    Tao, Zhiming; Hong, Yelong; Luo, Bin; Chen, Jingbiao; Guo, Hong

    2015-09-15

    We demonstrate an extended cavity Faraday laser system using an antireflection-coated laser diode as the gain medium and the isotope (87)Rb Faraday anomalous dispersion optical filter (FADOF) as the frequency selective device. Using this method, the laser wavelength works stably at the highest transmission peak of the isotope (87)Rb FADOF over the laser diode current from 55 to 140 mA and the temperature from 15°C to 35°C. Neither the current nor the temperature of the laser diode has significant influence on the output frequency. Compared with previous extended cavity laser systems operating at frequencies irrelevant to spectacular atomic transition lines, the laser system realized here provides a stable laser source with the frequency operating on atomic transitions for many practical applications.

  14. Effect of laser immunotherapy and surgery on the treatment of mouse mammary tumors

    NASA Astrophysics Data System (ADS)

    Chen, Vivian A.; Le, Henry; Li, Xiaosong; Wolf, Roman F.; Ferguson, Halie; Sarkar, Akhee; Liu, Hong; Nordquist, Robert E.; Chen, Wei R.

    2010-02-01

    Laser immunotherapy using laser photothermal therapy and immunological stimulation could achieve tumor-specific immune responses, as indicated by our previous pre-clinical and preliminary clinical studies. To further study the effect of laser immunotherapy, we conducted an investigation combining laser immunotherapy and surgery. After laser immunotherapy, treated tumors were surgically removed at different time points. The survival rates of treated mice were compared among different groups. Furthermore, the cured mice were rechallenged to test the immunity induced by laser immunotherapy. Our results showed that the mice treated with surgical removal one week after laser immunotherapy had the highest survival rate (77%). When the tumors were removed immediately after laser immunotherapy treatment, the survival rate was 57%. Most cured mice withstood tumor rechallenges, indicating an induction of tumor immunity by laser immunotherapy. The differentiations between different surgery groups indicate that the treated tumors have contributed to the immunological responses of the hosts.

  15. Stable CW Single Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking

    NASA Technical Reports Server (NTRS)

    Duerksen, Gary L.; Krainak, Michael A.

    1999-01-01

    Previously, single-frequency semiconductor laser operation using fiber Bragg gratings has been achieved by tWo methods: 1) use of the FBG as the output coupler for an anti-reflection-coated semiconductor gain element'; 2) pulsed operation of a gain-switched Fabry-Perot laser diode with FBG-optical and RF-electrical feedback'. Here, we demonstrate CW single frequency operation from a non-AR coated Fabry-Perot laser diode using only FBG optical feedback.

  16. Stable CW Single-Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking

    NASA Technical Reports Server (NTRS)

    Duerksen, Gary L.; Krainak, Michael A.

    1998-01-01

    Previously, single-frequency semiconductor laser operation using fiber Bragg gratings (FBG) has been achieved by two methods: (1) use of the FBG as the output coupler for an anti-reflection-coated semiconductor gain element; (2) pulsed operation of a gain-switched Fabry-Perot laser diode with FBG-optical and RF-electrical feedback. Here, we demonstrate CW single frequency operation from a non-AR coated Fabry-Perot laser diode using only FBG optical feedback.

  17. Developments in signal processing and interpretation in laser tapping

    NASA Astrophysics Data System (ADS)

    Perton, M.; Neron, C.; Blouin, A.; Monchalin, J.-P.

    2013-01-01

    A novel technique, called laser-tapping, based on the thermoelastic excitation by laser like laser-ultrasonics has been previously introduced for inspecting honeycomb and foam core structures. If the top skin is delaminated or detached from the substrate, the detached layer is driven into vibration. The interpretation of the vibrations in terms of Lamb wave resonances is first discussed for a flat bottom hole configuration and then used to determine appropriate signal processing for samples such as honeycomb structures.

  18. Laser Consolidation - A Novel One-Step Manufacturing Process for Making Net-Shape Functional Components

    DTIC Science & Technology

    2006-05-01

    dies. This process uses a laser beam to melt a controlled amount of injected powder on a base plate to deposit the first layer and on previous passes...Consolidation” to build functional net-shape components directly from metallic powder in one step [1-3]. The laser consolidation is a one-step computer-aided...A focused laser beam is irradiated on the substrate to create a molten pool, while metallic powder is injected simultaneously into the pool. A

  19. Remote Sensing of Turbine Engine Gases.

    DTIC Science & Technology

    1981-09-30

    Institute by lasers operating in the infrared compared to the visible and of Technology. Lexington, M A 0217 3. UV region. 00l8.9197/81/0900-1917S00.75 0...mini-TEA lasers used in both single- and dual- laser consists of a UV -preionized discharge between Rogowski laser DIAL systems, and a study has been...described previously [10]. The discharge is thyratron system. This research has led to a better understanding of triggered and may operate at a pulse

  20. Functional fabrication of recombinant human collagen-phosphorylcholine hydrogels for regenerative medicine applications.

    PubMed

    Mirazul Islam, M; Cėpla, Vytautas; He, Chaoliang; Edin, Joel; Rakickas, Tomas; Kobuch, Karin; Ruželė, Živilė; Bruce Jackson, W; Rafat, Mehrdad; Lohmann, Chris P; Valiokas, Ramūnas; Griffith, May

    2015-01-01

    The implant-host interface is a critical element in guiding tissue or organ regeneration. We previously developed hydrogels comprising interpenetrating networks of recombinant human collagen type III and 2-methacryloyloxyethyl phosphorylcholine (RHCIII-MPC) as substitutes for the corneal extracellular matrix that promote endogenous regeneration of corneal tissue. To render them functional for clinical application, we have now optimized their composition and thereby enhanced their mechanical properties. We have demonstrated that such optimized RHCIII-MPC hydrogels are suitable for precision femtosecond laser cutting to produce complementing implants and host surgical beds for subsequent tissue welding. This avoids the tissue damage and inflammation associated with manual surgical techniques, thereby leading to more efficient healing. Although we previously demonstrated in clinical testing that RHCIII-based implants stimulated cornea regeneration in patients, the rate of epithelial cell coverage of the implants needs improvement, e.g. modification of the implant surface. We now show that our 500μm thick RHCIII-MPC constructs comprising over 85% water are suitable for microcontact printing with fibronectin. The resulting fibronectin micropatterns promote cell adhesion, unlike the bare RHCIII-MPC hydrogel. Interestingly, a pattern of 30μm wide fibronectin stripes enhanced cell attachment and showed the highest mitotic rates, an effect that potentially can be utilized for faster integration of the implant. We have therefore shown that laboratory-produced mimics of naturally occurring collagen and phospholipids can be fabricated into robust hydrogels that can be laser profiled and patterned to enhance their potential function as artificial substitutes of donor human corneas. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  1. Laser in caries treatment--patients' experiences and opinions.

    PubMed

    Sarmadi, R; Hedman, E; Gabre, P

    2014-02-01

    The aim of this study was to obtain a deeper understanding of patient's experiences and perspectives after dental caries treatment with Er:YAG laser technology. Twelve patients aged 15-30 years who had undergone at least one laser caries excavation agreed to participate in an interview study. All the interviews were tape recorded and transcribed by a transcription agency. The transcribed texts were analysed using manifest and latent qualitative content analysis. The categories in this study were identified as choosing laser, understanding laser, encouraging dental care and my oral health. The motivation for laser treatment was described as dental fear in general, specific fear of needles or discomfort with the drill. The informants described the dentist's role as initiators of treatment and willing or unwilling facilitators. Laser treatment was described as safer and more carefully considered treatment. They felt generally safe with laser and were able to relax during the treatment. All interviewers described a positive impression of the laser, and words like 'up to date' and 'future-oriented' were used to describe laser. Laser treatment was considered less painful. The results indicate that patients find laser a feasible and convenient treatment option. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Pediatric endocanalicular diode laser dacryocystorhinostomy: results of a minimally invasive surgical technique.

    PubMed

    Uysal, Ismail Onder; Ozçimen, Muammer; Yener, Halil Ibrahim; Kal, Ali

    2011-09-01

    The purpose of this study was to evaluate the effectiveness of endocanalicular diode laser dacryocystorhinostomy (DCR), which is a minimally invasive surgical technique, in pediatric patients with congenital nasolacrimal duct obstruction (NLDO). A retrospective study was carried out on patients treated between October 2008 and August 2009 for nasolacrimal duct obstruction with an endocanalicular diode laser procedure. Patients diagnosed as having nasolacrimal duct obstruction were included in this study and an endocanalicular diode laser procedure was performed. The main outcome measures were patients' previous treatments, clinical presentation, operative and postoperative complications, postoperative follow-up and resolution of epiphora. Eighteen children (10 girls, 8 boys) with a mean age of 6.11 ± 2.08 years (range, 4-10) underwent 20 endocanalicular laser DCR operations for congenital NLDO. In all eyes (100%), there was a history of epiphora and chronic dacryocystitis; two (10%) presented with acute dacryocystitis. Previous procedures included probing and irrigation of all eyes (100%) and silicone tube intubation in nine eyes (45%). None of the patients underwent any previous DCR operations. During a mean postoperative follow-up period of 20.50 ± 3.24 months (range, 14-24 months), the anatomical success rate (patency of ostium on nasal endoscopy) was 100%, and the clinical success rate (resolution of epiphora) was 85%. Endocanalicular diode laser DCR is an effective treatment modality for pediatric patients with congenital NLDO that compares favorably with the reported success rates of external and endoscopic endonasal DCR. Moreover, it has an added advantage of shorter operative time, less morbidity and avoidance of overnight admission.

  3. Trends of 'urolithiasis: interventions, simulation, and laser technology' over the last 16 years (2000-2015) as published in the literature (PubMed): a systematic review from European section of Uro-technology (ESUT).

    PubMed

    Pietropaolo, Amelia; Proietti, Silvia; Geraghty, Rob; Skolarikos, Andreas; Papatsoris, Athanasios; Liatsikos, Evangelos; Somani, Bhaskar K

    2017-11-01

    To look at the bibliometric publication trends on 'Urolithiasis' and aspects of treatment and training associated with it over a period of 16 years from 2000 to 2015. To this end, we conducted this study to look at the publication trends associated with urolithiasis, including the use of simulation, laser technology, and all types of interventions for it. We performed a systematic review of the literature using PubMed over the last 16 years, from January 2000 to December 2015 for all published papers on 'Urolithiasis'. While there were no language restrictions, English language articles and all non-English language papers with published English abstracts were also included. Case reports, animal and laboratory studies, and those studies that did not have a published abstract were excluded from our analysis. We also analyzed the data in two time periods, period-1 (2000-2007) and period-2 (2008-2015). During the last 16 years, a total of 5343 papers were published on 'Urolithiasis', including 4787 in English language and 556 in non-English language. This included papers on URS (n = 1200), PCNL (n = 1715), SWL (n = 887), open stone surgery (n = 87), laparoscopic stone surgery (n = 209), pyelolithotomy (n = 35), simulation in Endourology (n = 82), and use of laser for stone surgery (n = 406). When comparing the two time periods, during period 2, the change was +171% (p = 0.007), +279% (p < 0.001), and -17% (p = 0.2) for URS, PCNL, and SWL, respectively. While there was a rise in laparoscopic surgery (+116%), it decreased for open stone surgery (-11%) and pyelolithotomy (-47%). A total of 82 papers have been published on simulation for stone surgery including 48 papers for URS (67% rise in period-2, p = 0.007), and 34 papers for PCNL (480% rise in period-2, p < 0.001). A rising trend for the use of laser was also seen in period 2 (increase of 126%, p < 0.02, from 124 papers to 281 papers). Published papers on intervention for Urolithiasis have risen over the last 16 years. While there has been a steep rise of URS and minimally invasive PCNL techniques, SWL and open surgery have shown a slight decline over this period. A similar increase has also been seen for the use of simulation and lasers in Endourology.

  4. Beam uniformity analysis of infrared laser illuminators

    NASA Astrophysics Data System (ADS)

    Allik, Toomas H.; Dixon, Roberta E.; Proffitt, R. Patrick; Fung, Susan; Ramboyong, Len; Soyka, Thomas J.

    2015-02-01

    Uniform near-infrared (NIR) and short-wave infrared (SWIR) illuminators are desired in low ambient light detection, recognition, and identification of military applications. Factors that contribute to laser illumination image degradation are high frequency, coherent laser speckle and low frequency nonuniformities created by the laser or external laser cavity optics. Laser speckle analysis and beam uniformity improvements have been independently studied by numerous authors, but analysis to separate these two effects from a single measurement technique has not been published. In this study, profiles of compact, diode laser NIR and SWIR illuminators were measured and evaluated. Digital 12-bit images were recorded with a flat-field calibrated InGaAs camera with measurements at F/1.4 and F/16. Separating beam uniformity components from laser speckle was approximated by filtering the original image. The goal of this paper is to identify and quantify the beam quality variation of illumination prototypes, draw awareness to its impact on range performance modeling, and develop measurement techniques and methodologies for military, industry, and vendors of active sources.

  5. Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.

    PubMed

    Roach, William P; Cain, Clarence P; Narayan, Drew G; Noojin, Gary D; Boppart, Stephen A; Birngruber, Reginald; Fujimoto, James G; Toth, Cynthia A

    2004-01-01

    We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induced breakdown (LIB) at the site of laser delivery. Single 3-ps pulses of 580-nm laser energy are delivered over a range of spot sizes to the retina of Macaca mulatta. The retinal response is captured sequentially with optical coherence tomography (OCT). The in vivo OCT images and the extent of pathology on final microscopic sections of the laser site are compared. With delivery of a laser pulse with peak irradiance greater than that required for LIB, OCT and light micrographs demonstrate inner retinal injury with many intraretinal and/or vitreous hemorrhages. In contrast, broad outer retinal injury with minimal to no choriocapillaris effect is seen after delivery of laser pulses to a larger retinal area (60 to 300 microm diam) when peak irradiance is less than that required for LIB. The broader lesions extend into the inner retina when higher energy delivery produces intraretinal injury. Microscopic examination of stained fixed tissues provide better resolution of retinal morphology than OCT. OCT provides less resolution but could be guided over an in vivo, visible retinal lesion for repeated sampling over time during the evolution of the lesion formation. For 3-ps visible wavelength laser pulses, varying the spot size and laser energy directly affects the extent of retinal injury. This again is believed to be partly due to the onset of LIB, as seen in previous studies. Spot-size dependence should be considered when comparing studies of retinal effects or when pursuing a specific retinal effect from ultrashort laser pulses. Copyright 2004 Society of Photo-Optical Instrumentation Engineers.

  6. [Mucosal tolerance and low level laser therapy: Is the delegation to radiation technicians possible?].

    PubMed

    Duchosal, S

    2015-10-01

    Mucositis remains a frequent complication of radiotherapy. Low level laser applications are used to accelerate the healing process. This technique is used routinely in our centre. It is performed by delegation by radiotherapists. The conditions of this delegation of tasks are addressed here. Copyright © 2015. Published by Elsevier SAS.

  7. Atomic layer deposition for fabrication of HfO2/Al2O3 thin films with high laser-induced damage thresholds.

    PubMed

    Wei, Yaowei; Pan, Feng; Zhang, Qinghua; Ma, Ping

    2015-01-01

    Previous research on the laser damage resistance of thin films deposited by atomic layer deposition (ALD) is rare. In this work, the ALD process for thin film generation was investigated using different process parameters such as various precursor types and pulse duration. The laser-induced damage threshold (LIDT) was measured as a key property for thin films used as laser system components. Reasons for film damaged were also investigated. The LIDTs for thin films deposited by improved process parameters reached a higher level than previously measured. Specifically, the LIDT of the Al2O3 thin film reached 40 J/cm(2). The LIDT of the HfO2/Al2O3 anti-reflector film reached 18 J/cm(2), the highest value reported for ALD single and anti-reflect films. In addition, it was shown that the LIDT could be improved by further altering the process parameters. All results show that ALD is an effective film deposition technique for fabrication of thin film components for high-power laser systems.

  8. Non-equilibrium modeling of UV laser induced plasma on a copper target in the presence of Cu{sup 2+}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ait Oumeziane, Amina, E-mail: a.aitoumeziane@gmail.com; Liani, Bachir; Parisse, Jean-Denis

    2016-03-15

    This work is a contribution to the understanding of UV laser ablation of a copper sample in the presence of Cu{sup 2+} species as well as electronic non-equilibrium in the laser induced plasma. This particular study extends a previous paper and develops a 1D hydrodynamic model to describe the behavior of the laser induced plume, including the thermal non-equilibrium between electrons and heavy particles. Incorporating the formation of doubly charged ions (Cu{sup 2+}) in such an approach has not been considered previously. We evaluate the effect of the presence of doubly ionized species on the characteristics of the plume, i.e.,more » temperature, pressure, and expansion velocity, and on the material itself by evaluating the ablation depth and plasma shielding effects. This study evaluates the effects of the doubly charged species using a non-equilibrium hydrodynamic approach which comprises a contribution to the understanding of the governing processes of the interaction of ultraviolet nanosecond laser pulses with metals and the parameter optimization depending on the intended application.« less

  9. Cataracts induced by neodymium-yttrium-aluminium-garnet laser lysis of vitreous floaters.

    PubMed

    Koo, Ellen H; Haddock, Luis J; Bhardwaj, Namita; Fortun, Jorge A

    2017-06-01

    Neodymium-yttrium-aluminium-garnet (Nd:YAG) laser vitreolysis has been proposed as a treatment modality for symptomatic vitreous floaters. The purpose of this paper is to report two cases of cataracts associated with posterior capsular compromise, induced by Nd:YAG laser vitreolysis for symptomatic vitreous floaters. Case series. Two patients who underwent ND:YAG laser vitreolysis for symptomatic floaters, presented with decline in visual acuity in the treated eye after the laser procedure. At the slit-lamp biomicroscope, each patient was found to have a posterior subcapsular cataract in the treated eye, with obvious loss of integrity of the posterior capsule. These two patients underwent cataract extraction by the same surgeon via phacoemulsification. Both eyes were found to have a defect in the posterior capsule intraoperatively. In both cases, a three-piece acrylic intraocular lens implant was placed in the sulcus, achieving optic capture. The best-corrected visual acuity (BCVA) was 20/20 in both patients, at 1 month following the surgery. At 2 months, one patient had a BCVA of 20/15. The second patient maintained a BCVA of 20/20 at 3 months. Secondary cataract formation accompanied by loss of integrity of the posterior capsule is a potential complication of Nd:YAG laser vitreolysis for symptomatic floaters. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Financial analysis of technology acquisition using fractionated lasers as a model.

    PubMed

    Jutkowitz, Eric; Carniol, Paul J; Carniol, Alan R

    2010-08-01

    Ablative fractional lasers are among the most advanced and costly devices on the market. Yet, there is a dearth of published literature on the cost and potential return on investment (ROI) of such devices. The objective of this study was to provide a methodological framework for physicians to evaluate ROI. To facilitate this analysis, we conducted a case study on the potential ROI of eight ablative fractional lasers. In the base case analysis, a 5-year lease and a 3-year lease were assumed as the purchase option with a $0 down payment and 3-month payment deferral. In addition to lease payments, service contracts, labor cost, and disposables were included in the total cost estimate. Revenue was estimated as price per procedure multiplied by total number of procedures in a year. Sensitivity analyses were performed to account for variability in model assumptions. Based on the assumptions of the model, all lasers had higher ROI under the 5-year lease agreement compared with that for the 3-year lease agreement. When comparing results between lasers, those with lower operating and purchase cost delivered a higher ROI. Sensitivity analysis indicates the model is most sensitive to purchase method. If physicians opt to purchase the device rather than lease, they can significantly enhance ROI. ROI analysis is an important tool for physicians who are considering making an expensive device acquisition. However, physicians should not rely solely on ROI and must also consider the clinical benefits of a laser. (c) Thieme Medical Publishers.

  11. Effect of laser peening with glycerol as plasma confinement layer

    NASA Astrophysics Data System (ADS)

    Tsuyama, Miho; Ehara, Naoya; Yamashita, Kazuma; Heya, Manabu; Nakano, Hitoshi

    2018-03-01

    The effects of controlling the plasma confinement layer on laser peening were investigated by measuring the hardness and residual stress of laser-peened stainless steels. The plasma confinement layer contributes to increasing the pressure of shock waves by suppressing the expansion of the laser-produced plasma. Most previous studies on laser peening have employed water as the plasma confinement layer. In this study, a glycerol solution is used in the context of a large acoustic impedance. It is found that this glycerol solution is superior to water in its ability to confine plasma and that suitable conditions exist for the glycerol solution to act as a plasma confinement layer to achieve efficient laser peening.

  12. Compact, passively Q-switched Nd:YAG laser for the MESSENGER mission to Mercury.

    PubMed

    Krebs, Danny J; Novo-Gradac, Anne-Marie; Li, Steven X; Lindauer, Steven J; Afzal, Robert S; Yu, Anthony W

    2005-03-20

    A compact, passively Q-switched Nd:YAG laser has been developed for the Mercury Laser Altimeter, an instrument on the Mercury Surface, Space Environment, Geochemistry, and Ranging mission to the planet Mercury. The laser achieves 5.4% efficiency with a near-diffraction-limited beam. It passed all space-flight environmental tests at subsystem, instrument, and satellite integration testing and successfully completes a postlaunch aliveness check en route to Mercury. The laser design draws on a heritage of previous laser altimetry missions, specifically the Ice Cloud and Elevation Satellite and the Mars Global Surveyor, but incorporates thermal management features unique to the requirements of an orbit of the planet Mercury.

  13. Application of a liquid crystal spatial light modulator to laser marking.

    PubMed

    Parry, Jonathan P; Beck, Rainer J; Shephard, Jonathan D; Hand, Duncan P

    2011-04-20

    Laser marking is demonstrated using a nanosecond (ns) pulse duration laser in combination with a liquid crystal spatial light modulator to generate two-dimensional patterns directly onto thin films and bulk metal surfaces. Previous demonstrations of laser marking with such devices have been limited to low average power lasers. Application in the ns regime enables more complex, larger scale marks to be generated with more widely available and industrially proven laser systems. The dynamic nature of the device is utilized to improve mark quality by reducing the impact of the inherently speckled intensity distribution across the generated image and reduce thermal effects in the marked surface. © 2011 Optical Society of America

  14. Microwave accelerator E-beam pumped laser

    DOEpatents

    Brau, Charles A.; Stein, William E.; Rockwood, Stephen D.

    1980-01-01

    A device and method for pumping gaseous lasers by means of a microwave accelerator. The microwave accelerator produces a relativistic electron beam which is applied along the longitudinal axis of the laser through an electron beam window. The incident points of the electron beam on the electron beam window are varied by deflection coils to enhance the cooling characteristics of the foil. A thyratron is used to reliably modulate the microwave accelerator to produce electron beam pulses which excite the laser medium to produce laser pulse repetition frequencies not previously obtainable. An aerodynamic window is also disclosed which eliminates foil heating problems, as well as a magnetic bottle for reducing laser cavity length and pressures while maintaining efficient energy deposition.

  15. Interaction of 1.05 μm and 0.53 μm lasers with gold disks

    NASA Astrophysics Data System (ADS)

    Shenye, Liu; Yaonan, Ding; Zhijian, Zheng; Daoyuan, Tang

    1996-05-01

    Gold disks were irradiated with 1.05 μm and 0.53 μm lasers at pulse duration of ˜0.8 ns, intensity ranging from 5×1013 W/cm2 to 4×1015 W/cm2 on the SHEN GUANG I laser facility in China. The experimental results of laser absorption, scattering light, x-ray emission and plasma blow-off are presented in this paper. When the laser irradiated the gold disk obliquely, the angular distribution of scattered lights produced by 0.53 μm lasers disagree with that predicted by the Brillouin scattering theory. The angular distribution is different from that reported previously by the others.

  16. Extending the solvent-free MALDI sample preparation method.

    PubMed

    Hanton, Scott D; Parees, David M

    2005-01-01

    Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important technique to characterize many different materials, including synthetic polymers. MALDI mass spectral data can be used to determine the polymer average molecular weights, repeat units, and end groups. One of the key issues in traditional MALDI sample preparation is making good solutions of the analyte and the matrix. Solvent-free sample preparation methods have been developed to address these issues. Previous results of solvent-free or dry prepared samples show some advantages over traditional wet sample preparation methods. Although the results of the published solvent-free sample preparation methods produced excellent mass spectra, we found the method to be very time-consuming, with significant tool cleaning, which presents a significant possibility of cross contamination. To address these issues, we developed an extension of the solvent-free method that replaces the mortar and pestle grinding with ball milling the sample in a glass vial with two small steel balls. This new method generates mass spectra with equal quality of the previous methods, but has significant advantages in productivity, eliminates cross contamination, and is applicable to liquid and soft or waxy analytes.

  17. EAU guidelines on laser technologies.

    PubMed

    Herrmann, Thomas R W; Liatsikos, Evangelos N; Nagele, Udo; Traxer, Olivier; Merseburger, Axel S

    2012-04-01

    The European Association of Urology (EAU) Guidelines Office has set up a guideline working panel to analyse the scientific evidence published in the world literature on lasers in urologic practice. Review the physical background and physiologic and technical aspects of the use of lasers in urology, as well as current clinical results from these new and evolving technologies, together with recommendations for the application of lasers in urology. The primary objective of this structured presentation of the current evidence base in this area is to assist clinicians in making informed choices regarding the use of lasers in their practice. Structured literature searches using an expert consultant were designed for each section of this document. Searches were carried out in the Cochrane Database of Systematic Reviews, the Cochrane Central Register of Controlled Trials, and Medline and Embase on the Dialog/DataStar platform. The controlled terminology of the respective databases was used, and both Medical Subject Headings and EMTREE were analysed for relevant entry terms. One Cochrane review was identified. Depending on the date of publication, the evidence for different laser treatments is heterogeneous. The available evidence allows treatments to be classified as safe alternatives for the treatment of bladder outlet obstruction in different clinical scenarios, such as refractory urinary retention, anticoagulation, and antiplatelet medication. Laser treatment for bladder cancer should only be used in a clinical trial setting or for patients who are not suitable for conventional treatment due to comorbidities or other complications. For the treatment of urinary stones and retrograde endoureterotomy, lasers provide a standard tool to augment the endourologic procedure. In benign prostatic obstruction (BPO), laser vaporisation, resection, or enucleation are alternative treatment options. The standard treatment for BPO remains transurethral resection of the prostate for small to moderate size prostates and open prostatectomy for large prostates. Laser energy is an optimal treatment method for disintegrating urinary stones. The use of lasers to treat bladder tumours and in laparoscopy remains investigational. Copyright © 2012 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  18. Laser probes for noninvasive coagulation of subsurface tissues

    NASA Astrophysics Data System (ADS)

    Chung, Chia-Chun; Permpongkosol, Sompol; Varkarakis, Ioannis M.; Lima, Guilherme; Franco, Nicholas; Hayman, Michael H.; Nicol, Theresa; Fried, Nathaniel M.

    2006-02-01

    Previous ex vivo tissue studies utilizing deep laser heating combined with contact cooling of the tissue surface produced noninvasive thermal destruction of subsurface tissue structures in skin and liver samples. This study describes the design and preliminary in vivo testing of two integrated laser/cooling probes for simultaneous Nd:YAG laser irradiation and sapphire contact cooling of liver and skin tissues in an in vivo, acute porcine model for potential use in laparoscopic and endoscopic surgery. Nd:YAG laser radiation with a wavelength of 1.06 μm, power of 20 W, 7.5-mm-diameter spot, 500-ms pulse length, and repetition rate of 0.625 Hz, was delivered to the tissue with a total irradiation time of 16 s. The tissue surface was continuously cooled with a sapphire plate maintained at -5 °C, and with pre- and post-ablation cooling times measuring 120 s and 30 s, resulting in a total operation time of 166 s per a lesion. Thermal lesions were created in liver and skin at a 1-mm depth below the tissue surface and with a 3-4 mm diameter. The laser parameters and lesion dimensions were comparable to previous ex vivo tissue studies. Preliminary in vivo animal studies demonstrate noninvasive creation of subsurface thermal lesions in tissue using Nd:YAG laser irradiation in conjunction with sapphire contact cooling. Chronic wound healing studies will be necessary to optimize the laser and cooling parameters. Potential clinical applications include endoscopic laser treatment of female stress urinary incontinence and thermal coagulation of early stage bladder tumors.

  19. Investigating MALDI MSI parameters (Part 1) - A systematic survey of the effects of repetition rates up to 20kHz in continuous raster mode.

    PubMed

    Steven, Rory T; Dexter, Alex; Bunch, Josephine

    2016-07-15

    Recent developments in laser performance, combined with the desire for increases in detected ion intensity and throughput, have led to the adoption of high repetition-rate diode-pumped solid-state (DPSS) lasers in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI). Previous studies have demonstrated a more complex relationship between detected ion intensity, stage raster speed and laser pulse repetition rate than the simple linear relationship between number of pulses and detected ion intensity that might be expected. Here we report, for the first time, the interrelated influence of varying laser energy, repetition rate and stage raster speed on detected ion intensity. Thin films of PC 34:1 lipid standard and murine brain tissue with CHCA are analysed by continuous stage raster MALDI MSI. Contrary to previous reports, the optimum laser repetition rate is found to be dependent on both laser energy and stage raster speed and is found to be as high as 20kHz under some conditions. The effects of different repetition rates and raster speeds are also found to vary for different ion species within MALDI MSI of tissue and so may be significant when either targeting specific molecules or seeking to minimize bias. A clear dependence on time between laser pulses is also observed indicating the underlying mechanisms may be related to on-plate hysteresis-exhibiting processes such as matrix chemical modification. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. The application of robotics to microlaryngeal laser surgery.

    PubMed

    Buckmire, Robert A; Wong, Yu-Tung; Deal, Allison M

    2015-06-01

    To evaluate the performance of human subjects, using a prototype robotic micromanipulator controller in a simulated, microlaryngeal operative setting. Observational cross-sectional study. Twenty-two human subjects with varying degrees of laser experience performed CO2 laser surgical tasks within a simulated microlaryngeal operative setting using an industry standard manual micromanipulator (MMM) and a prototype robotic micromanipulator controller (RMC). Accuracy, repeatability, and ablation consistency measures were obtained for each human subject across both conditions and for the preprogrammed RMC device. Using the standard MMM, surgeons with >10 previous laser cases performed superior to subjects with fewer cases on measures of error percentage and cumulative error (P = .045 and .03, respectively). No significant differences in performance were observed between subjects using the RMC device. In the programmed (P/A) mode, the RMC performed equivalently or superiorly to experienced human subjects on accuracy and repeatability measures, and nearly an order of magnitude better on measures of ablation consistency. The programmed RMC performed significantly better for repetition error when compared to human subjects with <100 previous laser cases (P = .04). Experienced laser surgeons perform better than novice surgeons on tasks of accuracy and repeatability using the MMM device but roughly equivalently using the novel RMC. Operated in the P/A mode, the RMC performs equivalently or superior to experienced laser surgeons using the industry standard MMM for all measured parameters, and delivers an ablation consistency nearly an order of magnitude better than human laser operators. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atanasov, Petar A., E-mail: paatanas@ie.bas.bg; Nedyalkov, Nikolay N.; Valova, Eugenia I.

    We present an experimental analysis on surface structuring of polydimethylsiloxane films with UV (263 nm) femtosecond laser pulses, in air. Laser processed areas are analyzed by optical microscopy, SEM, and μ-Raman spectroscopy. The laser-treated sample shows the formation of a randomly nanostructured surface morphology. μ-Raman spectra, carried out at both 514 and 785 nm excitation wavelengths, prior and after laser treatment allow evidencing the changes in the sample structure. The influence of the laser fluence on the surface morphology is studied. Finally, successful electro-less metallization of the laser-processed sample is achieved, even after several months from the laser-treatment contrary to previous observationmore » with nanosecond pulses. Our findings address the effectiveness of fs-laser treatment and chemical metallization of polydimethylsiloxane films with perspective technological interest in micro-fabrication devices for MEMS and nano-electromechanical systems.« less

  2. Laser theory with finite atom-field interacting time

    NASA Astrophysics Data System (ADS)

    Yu, Deshui; Chen, Jingbiao

    2008-07-01

    We investigate the influence of atomic transit time τ on the laser linewidth by the quantum Langevin approach. With comparing the bandwidths of cavity mode κ , atomic polarization γab , and atomic transit broadening τ-1 , we study the laser linewidth in different limits. We also discuss the spectrum of fluctuations of output field and the influence of pumping statistics on the output field.The influence of atomic transit time τ on laser field has not been carefully discussed before, to our knowledge. In particular, a laser operating in the region of γab≪τ-1≪κ/2 appears not to have been analyzed in previous laser theories. Our work could be a useful complementarity to laser theory. It is also an important theoretical foundation for the recently proposed active optical atomic clock based on bad-cavity laser mechanism.

  3. Laser shocking of 2024 and 7075 aluminum alloys

    NASA Technical Reports Server (NTRS)

    Clauer, A. H.; Fairand, B. P.; Slater, J. E.

    1977-01-01

    The effect of laser generated stress waves on the microstructure, hardness, strength and stress corrosion resistance of 2024 and 7075 aluminum alloys was investigated. Pulsed CO2 and neodymium-glass lasers were used to determine the effect of wavelength and pulse duration on pressure generation and material property changes. No changes in material properties were observed with CO2 laser. The strength and hardness of 2024-T351 and the strength of 7075-T73 aluminum alloys were substantially improved by the stress wave environments generated with the neodymium-glass laser. The mechanical properties of 2024-T851 and 7075-T651 were unchanged by the laser treatment. The correlation of the laser shock data with published results of flyer plate experiments demonstrated that a threshold pressure needed to be exceeded before strengthening and hardening could occur. Peak pressures generated by the pulsed laser source were less than 7.0 GPa which was below the threshold pressure required to change the mechanical properties of 2024-T851 and 7075-T651. Corrosion studies indicated that laser shocking increased the resistance to local attack in 2024-T351 and 7075-T651.

  4. Laser versus traditional techniques in cerebral and brain stem gliomas

    NASA Astrophysics Data System (ADS)

    Lombard, Gian F.

    1996-01-01

    In medical literature no significant studies have been published on the effectiveness of laser compared with traditional procedures in two series of cerebral gliomas; for this reason we have studied 220 tumors (200 supratentorial -- 20 brain stem gliomas), 110 operated upon with laser, 100 with conventional techniques. Four surgical protocols have been carried out: (1) traditional techniques; (2) carbon dioxide laser free hand; (3) carbon dioxide laser plus microscope; (4) multiple laser sources plus microscope plus neurosector plus CUSA. Two laser sources have been used alone or in combination (carbon dioxide -- Nd:YAG 1.06 or 1.32). Patients have been monitored for Karnofsky scale before and after operation, 12 - 24 and 36 months later; and for survival rate. Tumors were classified by histological examination, dimensions, vascularization, topography (critical or non critical areas). Results for supratentorial gliomas: survival time is the same in both series (laser and traditional). Post- op morbidity is significantly improved in the laser group (high grade sub-group); long term follow-up shows an improvement of quality of life until 36 months in the low grade sub-group.

  5. A novel dual‐wavelength, Nd:YAG, picosecond‐domain laser safely and effectively removes multicolor tattoos

    PubMed Central

    Schomacker, Kevin T.; Basilavecchio, Lisa D.; Plugis, Jessica M.; Bhawalkar, Jayant D.

    2015-01-01

    Background and Objectives Although nanosecond‐domain lasers have been the mainstay of laser tattoo removal for decades, recent disruptive innovations in laser design have introduced a new class of commercial Q‐switched lasers that generate picosecond‐domain pulses. Study A picosecond‐domain, Nd:YAG laser with a KTP frequency‐doubling crystal was used to treat 31 decorative tattoos in 21 subjects. Safety and effectiveness were determined by blinded evaluation of digital images in this prospective clinical study. Results The average clearance overall as evaluated by blinded observers evaluating randomized digital photographs was 79 ± 0.9% (mean ± sem) after an average of 6.5 treatments. Of the 31 tattoos completing treatment, 6 had evidence of mild hyper‐ or hypo‐pigmentation by evaluation of photographs. Conclusion The 350 picosecond, 532 nm, and 450 picosecond 1,064 nm Nd:YAG laser is safe and effective for removing decorative tattoos. Lasers Surg. Med. 47:542–548, 2015. © 2015 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. PMID:26175187

  6. Regulation of miRNA Expression by Low-Level Laser Therapy (LLLT) and Photodynamic Therapy (PDT)

    PubMed Central

    Kushibiki, Toshihiro; Hirasawa, Takeshi; Okawa, Shinpei; Ishihara, Miya

    2013-01-01

    Applications of laser therapy, including low-level laser therapy (LLLT), phototherapy and photodynamic therapy (PDT), have been proven to be beneficial and relatively less invasive therapeutic modalities for numerous diseases and disease conditions. Using specific types of laser irradiation, specific cellular activities can be induced. Because multiple cellular signaling cascades are simultaneously activated in cells exposed to lasers, understanding the molecular responses within cells will aid in the development of laser therapies. In order to understand in detail the molecular mechanisms of LLLT and PDT-related responses, it will be useful to characterize the specific expression of miRNAs and proteins. Such analyses will provide an important source for new applications of laser therapy, as well as for the development of individualized treatments. Although several miRNAs should be up- or down-regulated upon stimulation by LLLT, phototherapy and PDT, very few published studies address the effect of laser therapy on miRNA expression. In this review, we focus on LLLT, phototherapy and PDT as representative laser therapies and discuss the effects of these therapies on miRNA expression. PMID:23807510

  7. Regulation of miRNA expression by low-level laser therapy (LLLT) and photodynamic therapy (PDT).

    PubMed

    Kushibiki, Toshihiro; Hirasawa, Takeshi; Okawa, Shinpei; Ishihara, Miya

    2013-06-27

    Applications of laser therapy, including low-level laser therapy (LLLT), phototherapy and photodynamic therapy (PDT), have been proven to be beneficial and relatively less invasive therapeutic modalities for numerous diseases and disease conditions. Using specific types of laser irradiation, specific cellular activities can be induced. Because multiple cellular signaling cascades are simultaneously activated in cells exposed to lasers, understanding the molecular responses within cells will aid in the development of laser therapies. In order to understand in detail the molecular mechanisms of LLLT and PDT-related responses, it will be useful to characterize the specific expression of miRNAs and proteins. Such analyses will provide an important source for new applications of laser therapy, as well as for the development of individualized treatments. Although several miRNAs should be up- or down-regulated upon stimulation by LLLT, phototherapy and PDT, very few published studies address the effect of laser therapy on miRNA expression. In this review, we focus on LLLT, phototherapy and PDT as representative laser therapies and discuss the effects of these therapies on miRNA expression.

  8. Only lasers can be used for low level laser therapy.

    PubMed

    Moskvin, Sergey Vladimirovich

    2017-12-01

    The question of lasers' exclusivity, as well as the degree of influence of special properties of low-intensity laser illumination (LILI), such as coherence, polarity and monochromaticity, on the effectiveness of low level laser therapy (LLLT) continues to cause arguments. The study analyzes publications from 1973 to 2016, in which laser and conventional light sources are compared, and the following conclusions are drawn. First, there are a lot of publications with incorrect comparison or unfounded statements. Secondly, other sources of light are often meant by LILI without any justification. Thirdly, all studies, in which the comparison is carried out correctly and close parameters of the impact and the model are used, have a firm conclusion that laser light is much more effective. Fourthly, it is uniquely identified that the most important parameter that determines the efficiency of lasers is monochromaticity, i.e., a much narrower spectral width than for all other light sources. Only laser light sources can be used for LLLT! © Author(s) 2017. This article is published with open access by China Medical University.

  9. One-year outcomes of the da Vinci Study of VEGF Trap-Eye in eyes with diabetic macular edema.

    PubMed

    Do, Diana V; Nguyen, Quan Dong; Boyer, David; Schmidt-Erfurth, Ursula; Brown, David M; Vitti, Robert; Berliner, Alyson J; Gao, Bo; Zeitz, Oliver; Ruckert, Rene; Schmelter, Thomas; Sandbrink, Rupert; Heier, Jeff S

    2012-08-01

    To compare different doses and dosing regimens of Vascular Endothelial Growth Factor (VEGF) Trap-Eye with laser photocoagulation in eyes with diabetic macular edema (DME). Randomized, double-masked, multicenter, phase 2 clinical trial. Diabetic patients (n = 221) with center-involved DME. Participants were assigned randomly to 1 of 5 treatment regimens: VEGF Trap-Eye 0.5 mg every 4 weeks (0.5q4); 2 mg every 4 weeks (2q4); 2 mg every 8 weeks after 3 initial monthly doses (2q8); or 2 mg dosing as needed after 3 initial monthly doses (2PRN), or macular laser photocoagulation. The change in best-corrected visual acuity (BCVA) at 24 weeks (the primary end point) and at 52 weeks, proportion of eyes that gained 15 letters or more in Early Treatment of Diabetic Retinopathy Study (ETDRS) BCVA, and mean changes in central retinal thickness (CRT) from baseline. As previously reported, mean improvements in BCVA in the VEGF Trap-Eye groups at week 24 were 8.6, 11.4, 8.5, and 10.3 letters for 0.5q4, 2q4, 2q8, and 2PRN regimens, respectively, versus 2.5 letters for the laser group (P ≤ 0.0085 versus laser). Mean improvements in BCVA in the VEGF Trap-Eye groups at week 52 were 11.0, 13.1, 9.7, and 12.0 letters for 0.5q4, 2q4, 2q8, and 2PRN regimens, respectively, versus -1.3 letters for the laser group (P ≤ 0.0001 versus laser). Proportions of eyes with gains in BCVA of 15 or more ETDRS letters at week 52 in the VEGF Trap-Eye groups were 40.9%, 45.5%, 23.8%, and 42.2% versus 11.4% for laser (P = 0.0031, P = 0.0007, P = 0.1608, and P = 0.0016, respectively, versus laser). Mean reductions in CRT in the VEGF Trap-Eye groups at week 52 were -165.4 μm, -227.4 μm, -187.8 μm, and -180.3 μm versus -58.4 μm for laser (P < 0.0001 versus laser). Vascular Endothelial Growth Factor Trap-Eye generally was well tolerated. The most frequent ocular adverse events with VEGF Trap-Eye were conjunctival hemorrhage, eye pain, ocular hyperemia, and increased intraocular pressure, whereas common systemic adverse events included hypertension, nausea, and congestive heart failure. Significant gains in BCVA from baseline achieved at week 24 were maintained or improved at week 52 in all VEGF Trap-Eye groups. Vascular Endothelial Growth Factor Trap-Eye warrants further investigation for the treatment of DME. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Desktop Publishing: Its Impact on Community College Journalism.

    ERIC Educational Resources Information Center

    Grzywacz-Gray, John; And Others

    1987-01-01

    Illustrates the kinds of copy that can be created on Apple Macintosh computers and laser printers. Shows font and type specification options. Discusses desktop publishing costs, potential problems, and computer compatibility. Considers the use of computers in college journalism in production, graphics, accounting, advertising, and promotion. (AYC)

  11. Selective laser ablation of carious lesions using simultaneous scanned near-IR diode and CO2 lasers

    NASA Astrophysics Data System (ADS)

    Chan, Kenneth H.; Fried, Daniel

    2017-02-01

    Previous studies have established that carious lesions can be imaged with high contrast using near-IR wavelengths coincident with high water absorption, namely 1450-nm, without the interference of stains. It has been demonstrated that computer-controlled laser scanning systems utilizing IR lasers operating at high pulse repetition rates can be used for serial imaging and selective removal of caries lesions. In this study, a point-to-point scanning system was developed integrating a 1450-nm diode laser with the CO2 ablation laser. This approach is advantageous since it does not require an expensive near-IR camera. In this pilot study, we demonstrate the feasibility of a combined NIR and IR laser system for the selective removal of carious lesions.

  12. Selective Laser Ablation of Carious Lesions using Simultaneous Scanned Near-IR Diode and CO2 Lasers.

    PubMed

    Chan, Kenneth H; Fried, Daniel

    2017-01-28

    Previous studies have established that carious lesions can be imaged with high contrast using near-IR wavelengths coincident with high water absorption, namely 1450-nm, without the interference of stains. It has been demonstrated that computer-controlled laser scanning systems utilizing IR lasers operating at high pulse repetition rates can be used for serial imaging and selective removal of caries lesions. In this study, a point-to-point scanning system was developed integrating a 1450-nm diode laser with the CO 2 ablation laser. This approach is advantageous since it does not require an expensive near-IR camera. In this pilot study, we demonstrate the feasibility of a combined NIR and IR laser system for the selective removal of carious lesions.

  13. Development of laser technology in Poland: 2016

    NASA Astrophysics Data System (ADS)

    Jankiewicz, Zdzisław; Jabczyński, Jan K.; Romaniuk, Ryszard S.

    2016-12-01

    The paper is an introduction to the volume of proceedings and a concise digest of works presented during the XIth National Symposium on Laser Technology (SLT2016) [1]. The Symposium is organized since 1984 every three years [2-8]. SLT2016 was organized by the Institute of Optoelectronics, Military University of Technology (IO, WAT) [9], Warsaw, with cooperation of Warsaw University of Technology (WUT) [10], in Jastarnia on 27-30 September 2016. Symposium Proceedings are traditionally published by SPIE [11-19]. The meeting has gathered around 150 participants who presented around 120 research and technical papers. The Symposium, organized every 3 years is a good portrait of laser technology and laser applications development in Poland at university laboratories, governmental institutes, company R&D laboratories, etc. The SLT also presents the current technical projects under realization by the national research, development and industrial teams. Topical tracks of the Symposium, traditionally divided to two large areas - sources and applications, were: laser sources in near and medium infrared, picosecond and femtosecond lasers, optical fiber lasers and amplifiers, semiconductor lasers, high power and high energy lasers and their applications, new materials and components for laser technology, applications of laser technology in measurements, metrology and science, military applications of laser technology, laser applications in environment protection and remote detection of trace substances, laser applications in medicine and biomedical engineering, laser applications in industry, technologies and material engineering.

  14. An overview of clinical and experimental treatment modalities for port wine stains

    PubMed Central

    Chen, Jennifer K.; Ghasri, Pedram; Aguilar, Guillermo; van Drooge, Anne Margreet; Wolkerstorfer, Albert; Kelly, Kristen M.; Heger, Michal

    2014-01-01

    Port wine stains (PWS) are the most common vascular malformation of the skin, occurring in 0.3% to 0.5% of the population. Noninvasive laser irradiation with flashlamp-pumped pulsed dye lasers (selective photothermolysis) currently comprises the gold standard treatment of PWS; however, the majority of PWS fail to clear completely after selective photothermolysis. In this review, the clinically used PWS treatment modalities (pulsed dye lasers, alexandrite lasers, neodymium:yttrium-aluminum-garnet lasers, and intense pulsed light) and techniques (combination approaches, multiple passes, and epidermal cooling) are discussed. Retrospective analysis of clinical studies published between 1990 and 2011 was performed to determine therapeutic efficacies for each clinically used modality/technique. In addition, factors that have resulted in the high degree of therapeutic recalcitrance are identified, and emerging experimental treatment strategies are addressed, including the use of photodynamic therapy, immunomodulators, angiogenesis inhibitors, hypobaric pressure, and site-specific pharmaco-laser therapy. PMID:22305042

  15. Treatment of actinic cheilitis with the Er:YAG laser.

    PubMed

    Armenores, Paul; James, Craig L; Walker, Patrick C; Huilgol, Shyamala C

    2010-10-01

    Actinic cheilitis is a common condition with the potential to develop into squamous cell carcinoma. Current treatments have varying cure rates and complications. The role of the erbium:yttrium-aluminum-garnet (Er:YAG) laser in the treatment of actinic cheilitis has not been widely published, despite offering theoretical advantages over current treatment modalities. To evaluate the outcome of a series of patients treated with the Er:YAG laser for actinic cheilitis. This was a retrospective, interventional, nonrandomized, sequential case series set in a tertiary referral, dermatologic surgery unit. Ninety-nine consecutive patients with actinic cheilitis treated with the Er:YAG laser between January 2001 and June 2008 underwent a case note review, of which 77 went on to a structured telephone interview. The main outcome measures were a subjective improvement in lip symptoms related to actinic cheilitis and objective improvement in the lips at routine follow-up. Mean time to interview follow-up was 65.7 months. Of those interviewed, 92.2% believed there had been an improvement in the cosmetic appearance of their lips; one hundred percent believed the function of their lips had improved or remained unchanged; and 84.8% remained completely disease free at the time of follow-up. The majority of patients (93.5%) were satisfied with the laser treatment. Scarring as a direct result of the laser occurred in 5.1% of patients. Retrospective nature of data collection; inability to interview all patients who underwent treatment. The Er:YAG laser is a successful modality for the treatment of actinic cheilitis with good functional and cosmetic results and only a small risk of long-term scarring. It should be considered as a first-line treatment for the disease. Copyright © 2009 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  16. Relativistic Acceleration of Electrons Injected by a Plasma Mirror into a Radially Polarized Laser Beam.

    PubMed

    Zaïm, N; Thévenet, M; Lifschitz, A; Faure, J

    2017-09-01

    We propose a method to generate femtosecond, relativistic, and high-charge electron bunches using few-cycle and tightly focused radially polarized laser pulses. In this scheme, the incident laser pulse reflects off an overdense plasma that injects electrons into the reflected pulse. Particle-in-cell simulations show that the plasma injects electrons ideally, resulting in a dramatic increase of charge and energy of the accelerated electron bunch in comparison to previous methods. This method can be used to generate femtosecond pC bunches with energies in the 1-10 MeV range using realistic laser parameters corresponding to current kHz laser systems.

  17. Solar-pumped 80 W laser irradiated by a Fresnel lens.

    PubMed

    Ohkubo, Tomomasa; Yabe, Takashi; Yoshida, Kunio; Uchida, Shigeaki; Funatsu, Takayuki; Bagheri, Behgol; Oishi, Takehiro; Daito, Kazuya; Ishioka, Manabu; Nakayama, Yuichirou; Yasunaga, Norihito; Kido, Kouichirou; Sato, Yuji; Baasandash, Choijil; Kato, Kiyoshi; Yanagitani, Takagimi; Okamoto, Yoshiaki

    2009-01-15

    A solar-pumped 100 W class laser that features high efficiency and low cost owing to the use of a Fresnel lens and a chromium codoped neodymium YAG ceramic laser medium was developed. A laser output of about 80 W was achieved with combination of a 4 m(2) Fresnel lens and a pumping cavity as a secondary power concentrator. This output corresponds to 4.3% of conversion efficiency from solar power into laser, and the maximum output from a unit area of Fresnel lens was 20 W/m(2), which is 2.8 times larger than previous results with mirror-type concentrator.

  18. Design of ultrahigh brightness solar-pumped disk laser.

    PubMed

    Liang, Dawei; Almeida, Joana

    2012-09-10

    To significantly improve the solar-pumped laser beam brightness, a multi-Fresnel lens scheme is proposed for side-pumping either a single-crystal Nd:YAG or a core-doped ceramic Sm(3+) Nd:YAG disk. Optimum laser system parameters are found through ZEMAX and LASCAD numerical analysis. An ultrahigh laser beam figure of merit B of 53 W is numerically calculated, corresponding to a significant enhancement of more than 180 times over the previous record. 17.7 W/m(2) collection efficiency is also numerically attained. The strong thermal effects that have hampered present-day rod-type solar-pumped lasers can also be largely alleviated.

  19. Detailed Hydraulic Assessment Using a High-Resolution Piezocone Coupled to the GeoVis

    DTIC Science & Technology

    2008-04-01

    story. For example, the SCAPS laser - induced fluorescence (LIF) technology for petroleum hydrocarbons (commercialized as the Rapid Optical...impacts of oily or viscous waste materials smearing during camera deployment, the SCAPS laser induced fluorescence (LIF) probe uses the same type of...characterization techniques on DOD sites. ESTCP has previously funded efforts to help establish regulatory acceptance of the SCAPS Laser Induced Fluorescence (LIF

  20. Pointing and Jitter Control for the USNA Multi-Beam Combining System

    DTIC Science & Technology

    2013-05-10

    previous work, an adaptive H-infinity optimal controller has been developed to control a single beam using a beam position detector for feedback... turbulence and airborne particles, platform jitter, lack of feedback from the target , and current laser technology represent just a few of these...lasers. Solid state lasers, however, cannot currently provide high enough power levels to destroy a target using a single beam. On solid-state

  1. Laboratory Measurements of Cometary Photochemical Phenomena.

    DTIC Science & Technology

    1981-12-04

    PROGFIAM ELEMENT.PROJECT TASK Laser .Chemistry Division AREA & WORK UNIT NUMaZRS Department of Chemistry - Howard University NR.051-733 Wash’ ngtQn, D. C...William M. Jackson Laser Chemistry Division Department of Chemistry Howard University .Washington, D. C. 20059 / Published by Jet Propulsion Laboratory...MEASUREMENTS OF COMETARY PHOTOCHEMICAL PHENOMENA William M. Jackson Howard University Washington, DC 20059 Abstract Laboratory experiments are described

  2. Green frequency-doubled laser-beam propagation in high-temperature hohlraum plasmas.

    PubMed

    Niemann, C; Berger, R L; Divol, L; Froula, D H; Jones, O; Kirkwood, R K; Meezan, N; Moody, J D; Ross, J; Sorce, C; Suter, L J; Glenzer, S H

    2008-02-01

    We demonstrate propagation and small backscatter losses of a frequency-doubled (2omega) laser beam interacting with inertial confinement fusion hohlraum plasmas. The electron temperature of 3.3 keV, approximately a factor of 2 higher than achieved in previous experiments with open geometry targets, approaches plasma conditions of high-fusion yield hohlraums. In this new temperature regime, we measure 2omega laser-beam transmission approaching 80% with simultaneous backscattering losses of less than 10%. These findings suggest that good laser coupling into fusion hohlraums using 2omega light is possible.

  3. The analytical approach to optimization of active region structure of quantum dot laser

    NASA Astrophysics Data System (ADS)

    Korenev, V. V.; Savelyev, A. V.; Zhukov, A. E.; Omelchenko, A. V.; Maximov, M. V.

    2014-10-01

    Using the analytical approach introduced in our previous papers we analyse the possibilities of optimization of size and structure of active region of semiconductor quantum dot lasers emitting via ground-state optical transitions. It is shown that there are optimal length' dispersion and number of QD layers in laser active region which allow one to obtain lasing spectrum of a given width at minimum injection current. Laser efficiency corresponding to the injection current optimized by the cavity length is practically equal to its maximum value.

  4. Update on the use of diode laser in the management of benign prostate obstruction in 2014.

    PubMed

    Lusuardi, Lukas; Mitterberger, Michael; Hruby, Stephan; Kunit, Thomas; Kloss, Birgit; Engelhardt, Paul F; Sieberer, Manuela; Janetschek, Günter

    2015-04-01

    To determine the status quo in respect of various diode lasers and present the techniques in use, their results and complications. We assess how these compare with transurethral resection of the prostate and other types of laser in randomized controlled trials (RCTs). When adequate RCTs were not available, case studies and reports were evaluated. Laser for the treatment of benign prostatic hyperplasia (BPH) has aroused the interest and curiosity of urologists as well as patients. The patient associates the term laser with a successful and modern procedure. The journey that started with coagulative necrosis of prostatic adenoma based on neodymium: yttrium-aluminum-garnet (Nd:YAG) laser has culminated in endoscopic "enucleation" with holmium laser. Diode laser is being used in urology for about 10 years now. Various techniques have been employed to relieve bladder outlet obstruction due to BPH. The diode laser scenario is marked by a diversity of surgical techniques and wavelengths. We summarize the current published literature in respect of functional results and complications. More randomized controlled studies are needed to determine the position and the ideal technique of diode laser treatment for BPH.

  5. Laser R and D in the armed services

    NASA Astrophysics Data System (ADS)

    Seidel, R. W.; Bromberg, J. L.

    1984-09-01

    During the year, September 15, 1983 - September 15, 1984, Dr. Joan Lisa Bromberg has investigated the history of the laser through the interviewing of laser industry pioneers and leaders in California's Bay area and the Murray Hill branch of AT & T's Bell Labs. The status of processing of the interviewee's tapes is listed. During the course of the first year of our project, Dr. Robert W. Seidel has investigated the history of military laser research and development through the exploitation of the Department of Defense's Research and Development data bases, including the Research and Development Plans, Work Unit Information Summaries, and the Technical Report Abstracts of the Defense Technical Information Center; published and unpublished technical reports of military laser research and development available through DTIC and at military installations; visits to military installations and research facilities holding manuscript materials relating to history of laser research and development; and formal and informal interviews with participants in military laser R&D projects.

  6. Qualitative tissue differentiation by analysing the intensity ratios of atomic emission lines using laser induced breakdown spectroscopy (LIBS): prospects for a feedback mechanism for surgical laser systems.

    PubMed

    Kanawade, Rajesh; Mahari, Fanuel; Klämpfl, Florian; Rohde, Maximilian; Knipfer, Christian; Tangermann-Gerk, Katja; Adler, Werner; Schmidt, Michael; Stelzle, Florian

    2015-01-01

    The research work presented in this paper focuses on qualitative tissue differentiation by monitoring the intensity ratios of atomic emissions using 'Laser Induced Breakdown Spectroscopy' (LIBS) on the plasma plume created during laser tissue ablation. The background of this study is to establish a real time feedback control mechanism for clinical laser surgery systems during the laser ablation process. Ex-vivo domestic pig tissue samples (muscle, fat, nerve and skin) were used in this experiment. Atomic emission intensity ratios were analyzed to find a characteristic spectral line for each tissue. The results showed characteristic elemental emission intensity ratios for the respective tissues. The spectral lines and intensity ratios of these specific elements varied among the different tissue types. The main goal of this study is to qualitatively and precisely identify different tissue types for tissue specific laser surgery. © 2015 The Authors. Journal of Biophotonics published by WILEY-VCH Verlag.

  7. Fractional CO2 lasers for the treatment of atrophic acne scars: a review of the literature.

    PubMed

    Magnani, Lauren Rose; Schweiger, Eric S

    2014-04-01

    This review examines the efficacy and safety of fractional CO2 lasers for the treatment of atrophic scarring secondary to acne vulgaris. We reviewed 20 papers published between 2008 and 2013 that conducted clinical studies using fractional CO2 lasers to treat atrophic scarring. We discuss the prevalence and pathogenesis of acne scarring, as well as the laser mechanism. The histologic findings are included to highlight the ability of these lasers to induce the collagen reorganization and formation that improves scar appearance. We considered the number of treatments and different laser settings to determine which methods achieve optimal outcomes. We noted unique treatment regimens that yielded superior results. An overview of adverse effects is included to identify the most common ones. We concluded that more studies need to be done using uniform treatment parameters and reporting in order to establish which fractional CO2 laser treatment approaches allow for the greatest scar improvement.

  8. Non surgical laser and light in the treatment of chronic diseases: a review based on personal experiences

    NASA Astrophysics Data System (ADS)

    Longo, L.

    2010-11-01

    Since many years some effects of non surgical laser and light on biological tissue have been demonstrated, in vitro and in vivo. This review is based on the results obtained by me and my colleagues/follower in Italy. Aim of our study is to verify the anti-inflammatory and regenerative effects of non surgical laser and light therapy on patients with chronic diseases not good treatable with traditional therapies, as diabetes, and central nervous system injuries. In addition, many clinical data have emerged from double-blind trials on laser treatment of rheumatic diseases and in sports medicine. So, we would like to do a review on the state of the art of non surgical laser treatment in medicine, included aesthetic laser and light therapy field. We discuss the indications and limitations of aesthetic laser medicine, as concluded from the data analysis of the published literature and from over thirty years of personal experiences.

  9. KrF laser-induced OH fluorescence imaging in a supersonic combustion tunnel

    NASA Technical Reports Server (NTRS)

    Quagliaroli, T. M.; Laufer, G.; Hollo, S. D.; Krauss, R. H.; Whitehurst, R. B., III; Mcdaniel, J. C., Jr.

    1992-01-01

    Planar fluorescence images of OH in a continuous-flow, electrical-resistively heated, high enthalpy, hydrogen-air combustion tunnel, induced by a tunable KrF laser, were recorded. These images were compared to previously recorded fluorescence images induced by a doubled-dye laser under similar conditions. Images induced by the doubled-dye laser system demonstrated a severe distortion caused by absorption and fluorescence trapping. By contrast, images of the fluorescence induced by the tunable KrF laser retained the symmetry properties of the flow. Based on signal-to-noise ratio measurements the yield of the fluorescence induced by the doubled-dye laser is larger than the fluorescence yield induced by the KrF laser. The measurements in the present facility of OH fluorescence induced by the KrF laser were limited by the photon-statistical noise. Based 2 on this result, doubled-dye laser systems are recommended for OH imaging in small and OH lean (less than 10 exp 15/cu cm) facilities. KrF lasers should be selected otherwise.

  10. Eruptive keratoacanthomas following carbon dioxide laser resurfacing.

    PubMed

    Gewirtzman, A; Meirson, D H; Rabinovitz, H

    1999-08-01

    Skin resurfacing with the carbon dioxide (CO2) laser is currently a popular means of improving rhytides and scars. Scarring, hyperpigmentation, hypopigmentation, and infection are among the complications that have been known to occur in some patients treated with the CO2 laser. We wish to communicate a previously unreported complication of CO2 laser resurfacing-multiple eruptive keratoacanthomas. We describe a 61-year-old woman who presented with multiple eruptive keratoacanthomas subsequent to CO2 laser resurfacing. Her lesions were cultured for fungus and bacteria. Biopsy specimens of two lesions were taken. Cultures were negative for pathogens. Biopsy specimens revealed atypical squamous epithelial proliferation and changes consistent with eruptive keratoacanthomas. Multiple eruptive keratoacanthomas should be considered as a rare complication of CO2 laser resurfacing.

  11. Formation of laser-induced periodic surface structures on fused silica upon two-color double-pulse irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Höhm, S.; Herzlieb, M.; Rosenfeld, A.

    2013-12-16

    The formation of laser-induced periodic surface structures (LIPSS) upon irradiation of fused silica with multiple irradiation sequences consisting of laser pulse pairs (50 fs single-pulse duration) of two different wavelengths (400 and 800 nm) is studied experimentally. Parallel polarized double-pulse sequences with a variable delay Δt between −10 and +10 ps and between the individual fs-laser pulses were used to investigate the LIPSS periods versus Δt. These two-color experiments reveal the importance of the ultrafast energy deposition to the silica surface by the first laser pulse for LIPSS formation. The second laser pulse subsequently reinforces the previously seeded spatial LIPSSmore » frequencies.« less

  12. Improved performance of the laser guide star adaptive optics system at Lick Observatory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    An, J R; Avicola, K; Bauman, B J

    1999-07-20

    Results of experiments with the laser guide star adaptive optics system on the 3-meter Shane telescope at Lick Observatory have demonstrated a factor of 4 performance improvement over previous results. Stellar images recorded at a wavelength of 2 {micro}m were corrected to over 40% of the theoretical diffraction-limited peak intensity. For the previous two years, this sodium-layer laser guide star system has corrected stellar images at this wavelength to {approx}10% of the theoretical peak intensity limit. After a campaign to improve the beam quality of the laser system, and to improve calibration accuracy and stability of the adaptive optics systemmore » using new techniques for phase retrieval and phase-shifting diffraction interferometry, the system performance has been substantially increased. The next step will be to use the Lick system for astronomical science observations, and to demonstrate this level of performance with the new system being installed on the 10-meter Keck II telescope.« less

  13. Celebrating 50 years of the laser(Joint scientific session of the Physical Sciences Division of the Russian Academy of Sciences and of the Scientific Councils of the P N Lebedev Physical Institute, RAS and the A M Prokhorov General Physics Institute, RAS, 21 April 2010)

    NASA Astrophysics Data System (ADS)

    2011-01-01

    A joint scientific session of the Physical Sciences Division of the Russian Academy of Sciences (RAS) and the scientific councils of the P N Lebedev Physical Institute, RAS and the A M Prokhorov General Physics Institute, RAS dedicated to the 50th anniversary of the advent of the laser was held in the conference hall of the Lebedev Physical Institute on 21 April 2010. The following reports were put on the session's agenda posted on the website www.gpad.ac.ru of the Physical Sciences Division, RAS: (1) Alferov Zh I (A F Ioffe Physical-Technical Institute RAS, St. Petersburg) "Semiconductor heterostructure lasers"; (2) Bagaev S N (Institute of Laser Physics, Siberian Branch, RAS, Novosibirsk) "Ultrahigh-resolution spectra and their fundamental application"; (3) Masalov A V (P N Lebedev Physical Institute, RAS, Moscow) "Optical Department of the Lebedev Physical Institute: early work on lasers"; (4) Garnov S V, Shcherbakov I A (A M Prokhorov General Physics Institute, RAS, Moscow) "Laser sources of megavolt terahertz pulses"; (5) Sergeev A M, Khazanov E A (Institute of Applied Physics, RAS, Nizhny Novgorod) "Structural functions of a developed turbulence"; (6) Popov Yu M (P N Lebedev Physical Institute, RAS, Moscow) "The early history of semiconductor lasers"; (7) Manenkov A A (A M Prokhorov General Physics Institute, RAS, Moscow) "Self-focusing laser pulses: current state and future prospects". The papers written on the basis of reports 3, 4, 6, and 7 are published below. A comprehensive version of report 5 prepared in the form of a review paper is published in this issue of Physics-Uspekhi on p. 9. • Optical Department of the Lebedev Physical Institute: early work on lasers, A V Masalov Physics-Uspekhi, 2011, Volume 54, Number 1, Pages 87-91 • Laser methods for generating megavolt terahertz pulses, S V Garnov, I A Shcherbakov Physics-Uspekhi, 2011, Volume 54, Number 1, Pages 91-96 • The early history of the injection laser, Yu M Popov Physics-Uspekhi, 2011, Volume 54, Number 1, Pages 96-100 • Self-focusing of laser pulses: current state and future prospects, A A Manenkov Physics-Uspekhi, 2011, Volume 54, Number 1, Pages 100-104

  14. 25  W/m2 collection efficiency solar-pumped Nd:YAG laser by a heliostat-parabolic mirror system.

    PubMed

    Liang, D; Almeida, J; Vistas, C R

    2016-09-20

    A large aspheric fused silica lens was used to couple efficiently the concentrated solar radiation from the focal zone of a 1.5-m-diameter primary concentrator into a 4-mm-diameter, 35-mm-long Nd:YAG single-crystal rod within a conical pump cavity. Continuous-wave laser power of 29.3 W was measured, attaining 25.0  W/m2 solar laser collection efficiency, corresponding to a 19% increase over the previous record. Its laser beam figure of merit-the ratio between laser power and the product of Mx2, My2 beam quality factors-of 0.01 W is 1.6 times higher than that of a direct tracking solar laser with 30  W/m2 collection efficiency. A strong dependency of solar laser power on laser resonator cavity length was found.

  15. Nociception and inflammatory hyperalgesia evaluated in rodents using infrared laser stimulation after Trpv1 gene knockout or resiniferatoxin lesion.

    PubMed

    Mitchell, Kendall; Lebovitz, Evan E; Keller, Jason M; Mannes, Andrew J; Nemenov, Michael I; Iadarola, Michael J

    2014-04-01

    TRPV1 is expressed in a subpopulation of myelinated Aδ and unmyelinated C-fibers. TRPV1+ fibers are essential for the transmission of nociceptive thermal stimuli and for the establishment and maintenance of inflammatory hyperalgesia. We have previously shown that high-power, short-duration pulses from an infrared diode laser are capable of predominantly activating cutaneous TRPV1+ Aδ-fibers. Here we show that stimulating either subtype of TRPV1+ fiber in the paw during carrageenan-induced inflammation or following hind-paw incision elicits pronounced hyperalgesic responses, including prolonged paw guarding. The ultrapotent TRPV1 agonist resiniferatoxin (RTX) dose-dependently deactivates TRPV1+ fibers and blocks thermal nociceptive responses in baseline or inflamed conditions. Injecting sufficient doses of RTX peripherally renders animals unresponsive to laser stimulation even at the point of acute thermal skin damage. In contrast, Trpv1-/- mice, which are generally unresponsive to noxious thermal stimuli at lower power settings, exhibit withdrawal responses and inflammation-induced sensitization using high-power, short duration Aδ stimuli. In rats, systemic morphine suppresses paw withdrawal, inflammatory guarding, and hyperalgesia in a dose-dependent fashion using the same Aδ stimuli. The qualitative intensity of Aδ responses, the leftward shift of the stimulus-response curve, the increased guarding behaviors during carrageenan inflammation or after incision, and the reduction of Aδ responses with morphine suggest multiple roles for TRPV1+ Aδ fibers in nociceptive processes and their modulation of pathological pain conditions. Copyright © 2014. Published by Elsevier B.V.

  16. Distributed feedback interband cascade lasers with top grating and corrugated sidewalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Feng; Stocker, Michael; Pham, John

    Distributed feedback (DFB) interband cascade lasers (ICLs) with a 1st order top surface grating were designed and fabricated. Partially corrugated sidewalls were implemented to suppress high order lateral modes. The DFB ICLs have 4 mm long and 4.5 mu m wide ridge waveguides and are mounted epi-up on AlN submounts. We demonstrated a continuous-wave (CW) DFB ICL, from a first wafer which has a large detuning of the gain peak from the DFB wavelength, with a side mode suppression ratio of 30 dB. With proper matching of grating feedback and the gain peak wavelength for the second wafer, a DFBmore » ICL was demonstrated with a maximum CW output power and a maximum wall plug efficiency reaching 42 mW and 2%, respectively, at 25 degrees C. The lasing wavelengths of both lasers are around 3.3 mu m at 25 degrees C. Published by AIP Publishing.« less

  17. Low-power laser therapy for carpal tunnel syndrome: effective optical power

    PubMed Central

    Chen, Yan; Zhao, Cheng-qiang; Ye, Gang; Liu, Can-dong; Xu, Wen-dong

    2016-01-01

    Low-power laser therapy has been used for the non-surgical treatment of mild to moderate carpal tunnel syndrome, although its efficacy has been a long-standing controversy. The laser parameters in low-power laser therapy are closely related to the laser effect on human tissue. To evaluate the efficacy of low-power laser therapy, laser parameters should be accurately measured and controlled, which has been ignored in previous clinical trials. Here, we report the measurement of the effective optical power of low-power laser therapy for carpal tunnel syndrome. By monitoring the backside reflection and scattering laser power from human skin at the wrist, the effective laser power can be inferred. Using clinical measurements from 30 cases, we found that the effective laser power differed significantly among cases, with the measured laser reflection coefficient ranging from 1.8% to 54%. The reflection coefficient for 36.7% of these 30 cases was in the range of 10–20%, but for 16.7% of cases, it was higher than 40%. Consequently, monitoring the effective optical power during laser irradiation is necessary for the laser therapy of carpal tunnel syndrome. PMID:27630706

  18. NASA space geodesy program: Catalogue of site information

    NASA Technical Reports Server (NTRS)

    Bryant, M. A.; Noll, C. E.

    1993-01-01

    This is the first edition of the NASA Space Geodesy Program: Catalogue of Site Information. This catalogue supersedes all previous versions of the Crustal Dynamics Project: Catalogue of Site Information, last published in May 1989. This document is prepared under the direction of the Space Geodesy and Altimetry Projects Office (SGAPO), Code 920.1, Goddard Space Flight Center. SGAPO has assumed the responsibilities of the Crustal Dynamics Project, which officially ended December 31, 1991. The catalog contains information on all NASA supported sites as well as sites from cooperating international partners. This catalog is designed to provde descriptions and occupation histories of high-accuracy geodetic measuring sites employing space-related techniques. The emphasis of the catalog has been in the past, and continues to be with this edition, station information for facilities and remote locations utilizing the Satellite Laser Ranging (SLR), Lunar Laser Ranging (LLR), and Very Long Baseline Interferometry (VLBI) techniques. With the proliferation of high-quality Global Positioning System (GPS) receivers and Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) transponders, many co-located at established SLR and VLBI observatories, the requirement for accurate station and localized survey information for an ever broadening base of scientists and engineers has been recognized. It is our objective to provide accurate station information to scientific groups interested in these facilities.

  19. Stable CW Single-Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking

    NASA Technical Reports Server (NTRS)

    Duerksen, Gary L.; Krainak, Michael A.

    1999-01-01

    Previously, single-frequency semiconductor laser operation using fiber Bragg gratings has been achieved by two methods: 1) use of the FBG as the output coupler for an anti-reflection-coated semiconductor gain element'; 2) pulsed operation of a gain-switched Fabry-Perot laser diode with FBG-optical and RF-electrical feedback. Here, we demonstrate CW single frequency operation from a non-AR coated Fabry-Perot laser diode using only FBG optical feedback. We coupled a nominal 935 run-wavelength Fabry-Perot laser diode to an ultra narrow band (18 pm) FBG. When tuned by varying its temperature, the laser wavelength is pulled toward the centerline of the Bragg grating, and the spectrum of the laser output is seen to fall into three discrete stability regimes as measured by the side-mode suppression ratio.

  20. Direct solar-pumped iodine laser amplifier

    NASA Technical Reports Server (NTRS)

    Han, Kwang S.; Kim, K. H.; Stock, L. V.

    1986-01-01

    In order to evaluate the feasibility of the solar pumped dye laser, the parametric study of a dye laser amplifier pumped by a solar simulator and flashlamp was carried out, and the amplifier gains were measured at various pump beam irradiances on the dye cell. Rhodamine 6G was considered as a candidate for the solar pumped laser because of its good utilization of the solar spectrum and high quantum efficiency. The measurement shows that a solar concentration of 20,000 is required to reach the threshold of the dye. The work to construct a kinetic model algorithm which predicts the output parameter of laser was progressed. The kinetic model was improved such that there is good agreement between the theoretical model and experimental data for the systems defined previously as flashlamp pumped laser oscillator, and the long path length solar pumped laser.

  1. Frequency stabilization of multiple lasers on a single medium-finesse cavity

    NASA Astrophysics Data System (ADS)

    Han, Chengyin; Zhou, Min; Gao, Qi; Li, Shangyan; Zhang, Shuang; Qiao, Hao; Ai, Di; Zhang, Mengya; Lou, Ge; Luo, Limeng; Xu, Xinye

    2018-04-01

    We present a simple, compact, and robust frequency stabilization system of three lasers operating at 649, 759, and 770 nm, respectively. These lasers are applied in experiments on ytterbium optical lattice clocks, for which each laser needs to have a linewidth of a few hundred or tens of kilohertz while maintaining a favorable long-term stability. Here, a single medium-finesse cavity is adopted as the frequency reference and the standard Pound-Drever-Hall technique is used to stabilize the laser frequencies. Based on the independent phase modulation, multiple-laser locking is demonstrated without mutual intervention. The locked lasers are measured to have a linewidth of 100 kHz and the residual frequency drift is about 78.5 Hz s-1. This kind of setup provides a construction that is much simpler than that in previous work.

  2. Observation of 690 MV m -1 Electron Accelerating Gradient with a Laser-Driven Dielectric Microstructure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wootton, K. P.; Wu, Z.; Cowan, B. M.

    Acceleration of electrons using laser-driven dielectric microstructures is a promising technology for the miniaturization of particle accelerators. In this work, experimental results are presented of relativistic electron acceleration with 690±100 MVm -1 gradient. This is a record-high accelerating gradient for a dielectric microstructure accelerator, nearly doubling the previous record gradient. To reach higher acceleration gradients the present experiment employs 90 fs duration laser pulses.

  3. Nonpolar InGaN/GaN Core-Shell Single Nanowire Lasers.

    PubMed

    Li, Changyi; Wright, Jeremy B; Liu, Sheng; Lu, Ping; Figiel, Jeffrey J; Leung, Benjamin; Chow, Weng W; Brener, Igal; Koleske, Daniel D; Luk, Ting-Shan; Feezell, Daniel F; Brueck, S R J; Wang, George T

    2017-02-08

    We report lasing from nonpolar p-i-n InGaN/GaN multi-quantum well core-shell single-nanowire lasers by optical pumping at room temperature. The nanowire lasers were fabricated using a hybrid approach consisting of a top-down two-step etch process followed by a bottom-up regrowth process, enabling precise geometrical control and high material gain and optical confinement. The modal gain spectra and the gain curves of the core-shell nanowire lasers were measured using micro-photoluminescence and analyzed using the Hakki-Paoli method. Significantly lower lasing thresholds due to high optical gain were measured compared to previously reported semipolar InGaN/GaN core-shell nanowires, despite significantly shorter cavity lengths and reduced active region volume. Mode simulations show that due to the core-shell architecture, annular-shaped modes have higher optical confinement than solid transverse modes. The results show the viability of this p-i-n nonpolar core-shell nanowire architecture, previously investigated for next-generation light-emitting diodes, as low-threshold, coherent UV-visible nanoscale light emitters, and open a route toward monolithic, integrable, electrically injected single-nanowire lasers operating at room temperature.

  4. Nonpolar InGaN/GaN core–shell single nanowire lasers

    DOE PAGES

    Li, Changyi; Wright, Jeremy Benjamin; Liu, Sheng; ...

    2017-01-24

    We report lasing from nonpolar p-i-n InGaN/GaN multi-quantum well core–shell single-nanowire lasers by optical pumping at room temperature. The nanowire lasers were fabricated using a hybrid approach consisting of a top-down two-step etch process followed by a bottom-up regrowth process, enabling precise geometrical control and high material gain and optical confinement. The modal gain spectra and the gain curves of the core–shell nanowire lasers were measured using micro-photoluminescence and analyzed using the Hakki-Paoli method. Significantly lower lasing thresholds due to high optical gain were measured compared to previously reported semipolar InGaN/GaN core–shell nanowires, despite significantly shorter cavity lengths and reducedmore » active region volume. Mode simulations show that due to the core–shell architecture, annular-shaped modes have higher optical confinement than solid transverse modes. Furthermore, the results show the viability of this p-i-n nonpolar core–shell nanowire architecture, previously investigated for next-generation light-emitting diodes, as low-threshold, coherent UV–visible nanoscale light emitters, and open a route toward monolithic, integrable, electrically injected single-nanowire lasers operating at room temperature.« less

  5. 100 positive double-blind studies: enough or too little?

    NASA Astrophysics Data System (ADS)

    Tuner, Jan; Hode, Lars

    2000-06-01

    A major argument among the opponents of laser therapy has been the absence of scientific documentation. This was a valid position in the 80s and partly in the 90s. But today, is this still a sound argument. There are more than 2,000 published studies in the field, including meeting abstracts and anecdotal reports. The vast majority of these papers reports positive effects of LLLT in vitro and in vivo. It is fair to argue that negative results are less prone to be published, but certainly more than 80 percent of the published studies are positive. In the field of dentistry, for instance, the positive percentage is well above 90 percent. The present literature study will look at the heart of the positive documentation: the positive double blind studies. It may come as a surprise to many critics that there are more than 100 positive double blind studies in the field laser therapy. This is a god base for a further understanding of the effects of low level laser in the clinical setting. We must, however, be as critical as the sceptics themselves in order to obtain a constructive dialogue between 'attorneys' and sceptics. In this paper, a critical review of 100 positive double blind studies will be presented.

  6. TRACE ANALYSIS OF FLUORESCEIN-DERIVATIZED PHENOXY ACID HERBICIDES BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY WITH LASER-INDUCTED FLUORESCENCE DETECTION

    EPA Science Inventory

    Micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection was used for the trace analysis of phenoxy acid herbicides. Capillary electrophoresis (CE) with LIF detection, which has not previously been used for pesticide analysis, overcomes the po...

  7. Theoretical studies of solar lasers and converters

    NASA Technical Reports Server (NTRS)

    Heinbockel, John H.

    1988-01-01

    The previously constructed one dimensional model for the simulated operation of an iodine laser assumed that the perfluoroalkyl iodide gas n-C3F7I was incompressible. The present study removes this simplifying assumption and considers n-C3F7I as a compressible fluid.

  8. Laser materials for the 0.67-microns to 2.5-microns range

    NASA Technical Reports Server (NTRS)

    Toda, Minoru; Zamerowski, Thomas J.; Ladany, Ivan; Martinelli, Ramon U.

    1987-01-01

    Basic requirements for obtaining injection laser action in III-V semiconductors are discussed briefly. A detailed review is presented of materials suitable for lasers emitting at 0.67, 1.44, 1.93, and 2.5 microns. A general approach to the problem is presented, based on curves of materials properties published by Sasaki et al. It is also shown that these curves, although useful, may need correction in certain ranges. It is deduced that certain materials combinations, either proposed in the literature or actually tried, are not appropriate for double heterostructure lasers, because the refractive index of the cladding material is higher than the index of the active material, thus resulting in no waveguiding, and high threshold currents. Recommendations are made about the most promising approach to the achievement of laser action in the four wavelengths mentioned above.

  9. Comment on 'Dark pulse emission of a fiber laser'

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coen, Stephane; Sylvestre, Thibaut; Institut FEMTO-ST, Universite de Franche-Comte, CNRS UMR 6174, F-25030 Besancon

    A recent Brief Report [Zhang et al., Phys. Rev. A 80, 045803 (2009)] presents experimental results in which dark pulses are generated in a fiber laser. Contrary to what is presented, the data published in that Brief Report do not support the claim that the duration of the dark dips are in the 8 ps range and that these pulses are related to genuine dark solitons.

  10. Accelerating the Kill Chain via Future Unmanned Aircraft

    DTIC Science & Technology

    2007-04-01

    Controller JTRS Joint Tactical Radio System Lasercom Laser communications LDHD Low Density High Demand LEO Low Earth Orbit LGB Laser Guided Bomb...published the Unmanned Aircraft Systems Roadmap 2005 that included the terms Unmanned Aircraft System (UAS) and Unmanned Aircraft (UA). This...comprehensive publication used the term Unmanned Aircraft Systems when referring to the entire system and the term Unmanned Aircraft when referring only to the

  11. Laser applications in advanced chip packaging

    NASA Astrophysics Data System (ADS)

    Müller, Dirk; Held, Andrew; Pätzel, Rainer; Clark, Dave; van Nunen, Joris

    2016-03-01

    While applications such as drilling μ-vias and laser direct imaging have been well established in the electronics industry, the mobile device industry's push for miniaturization is generating new demands for packaging technologies that allow for further reduction in feature size while reducing manufacturing cost. CO lasers have recently become available and their shorter wavelength allows for a smaller focus and drilling hole diameters down to 25μm whilst keeping the cost similar to CO2 lasers. Similarly, nanosecond UV lasers have gained significantly in power, become more reliable and lower in cost. On a separate front, the cost of ownership reduction for Excimer lasers has made this class of lasers attractive for structuring redistribution layers of IC substrates with feature sizes down to 2μm. Improvements in reliability and lower up-front cost for picosecond lasers is enabling applications that previously were only cost effective with mechanical means or long-pulsed lasers. We can now span the gamut from 100μm to 2μm for via drilling and can cost effectively structure redistribution layers with lasers instead of UV lamps or singulate packages with picosecond lasers.

  12. An overview of the laser ranging method of space laser altimeter

    NASA Astrophysics Data System (ADS)

    Zhou, Hui; Chen, Yuwei; Hyyppä, Juha; Li, Song

    2017-11-01

    Space laser altimeter is an active remote sensing instrument to measure topographic map of Earth, Moon and planetary. The space laser altimeter determines the range between the instrument and laser footprint by measuring round trip time of laser pulse. The return pulse reflected from ground surface is gathered by the receiver of space laser altimeter, the pulsewidth and amplitude of which are changeable with the variability of the ground relief. Meantime, several kinds of noise overlapped on the return pulse signal affect its signal-to-noise ratio. To eliminate the influence of these factors that cause range walk and range uncertainty, the reliable laser ranging methods need to be implemented to obtain high-precision range results. Based on typical space laser altimeters in the past few decades, various ranging methods are expounded in detail according to the operational principle of instruments and timing method. By illustrating the concrete procedure of determining time of flight of laser pulse, this overview provides the comparison of the employed technologies in previous and undergoing research programs and prospect innovative technology for space laser altimeters in future.

  13. Wideband laser locking to an atomic reference with modulation transfer spectroscopy.

    PubMed

    Negnevitsky, V; Turner, L D

    2013-02-11

    We demonstrate that conventional modulated spectroscopy apparatus, used for laser frequency stabilization in many atomic physics laboratories, can be enhanced to provide a wideband lock delivering deep suppression of frequency noise across the acoustic range. Using an acousto-optic modulator driven with an agile oscillator, we show that wideband frequency modulation of the pump laser in modulation transfer spectroscopy produces the unique single lock-point spectrum previously demonstrated with electro-optic phase modulation. We achieve a laser lock with 100 kHz feedback bandwidth, limited by our laser control electronics. This bandwidth is sufficient to reduce frequency noise by 30 dB across the acoustic range and narrows the imputed linewidth by a factor of five.

  14. Amplitude Noise Reduction of Ion Lasers with Optical Feedback

    NASA Technical Reports Server (NTRS)

    Herring, Gregory C.

    2011-01-01

    A reduction in amplitude noise on the output of a multi-mode continuous-wave Ar-ion laser was previously demonstrated when a fraction of the output power was retroreflected back into the laser cavity. This result was reproduced in the present work and a Fabry-Perot etalon was used to monitor the longitudinal mode structure of the laser. A decrease in the number of operating longitudinal cavity modes was observed simultaneously with the introduction of the optical feedback and the onset of the amplitude noise reduction. The noise reduction is a result of a reduced number of lasing modes, resulting in less mode beating and amplitude fluctuations of the laser output power.

  15. Publications of LASL research, 1975

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerr, A.K.

    1976-09-01

    This bibliography lists unclassified 1975 publications of work done at the Los Alamos Scientific Laboratory and those earlier publications that were received too late for inclusion in earlier compilations. Papers published in 1975 are included regardless of when they were actually written. Declassification of previously classified reports is considered to constitute publication. All classified issuances are omitted. The bibliography includes Los Alamos Scientific Laboratory reports, papers released as non-Los Alamos reports, journal articles, books, chapters of books, conference papers (whether published separately or as part of conference proceedings issued as books or reports), papers published in congressional hearings, theses, andmore » U.S. Patents. Publications by LASL authors which are not records of Laboratory-sponsored work are included when the Library becomes aware of them. The entries are arranged in sections by the following broad subject categories: aerospace studies; analytical technology; astrophysics; atomic and molecular physics, equation of state, opacity; biology and medicine; chemical dynamics and kinetics; chemistry; cryogenics; crystallography; CTR and plasma physics; earth science and engineering; energy (nonnuclear); engineering and equipment; EPR, ESR, NMR studies; explosives and detonations; fission physics; health and safety; hydrodynamics and radiation transport; instruments; lasers; mathematics and computers; medium-energy physics; metallurgy and ceramics technology; neutronics and criticality studies; nuclear physics; nuclear safeguards; physics; reactor technology; solid state science; and miscellaneous (including Project Rover). Author, numerical, and KWIC indexes are included. (RWR)« less

  16. Lasers use in dental implantology.

    PubMed

    Romanos, Georgios E; Gupta, Bhumija; Yunker, Mike; Romanos, Enisa Begic; Malmstrom, Hans

    2013-06-01

    The purpose of this literature review was to evaluate the present use of different laser systems in implant dentistry. A literature search of MEDLINE-PubMed for articles published, describing the use of lasers in implant dentistry, was performed and articles were critically reviewed by the investigators to determine the strength of evidence. The literature review reveals a limited number of randomized clinical trials with regard to laser use in dentistry. Although many case studies indicate extensive use of lasers and promising results in dental implantology, lasers may be used for uncovering submerged implants atraumatically to prevent crestal bone loss, recontouring periimplant soft tissues and sculpting emergence profile for prosthetic components, raising surgical flaps, osseous recontouring, and creating parabolic tissue architecture. Additionally, bone harvesting of block grafts, window preparation in sinus lift procedures, ridge splitting, and debridement of extraction sockets for immediate implant placement were described. Aside from the many benefits associated with the use of lasers in implant-related procedures, there are also risks to consider from the laser irradiation on the implant surface and the periimplant tissues. Therefore, an appropriate training on laser use is mandatory to increase the clinical outcome and to control the potential of complications.

  17. Pressure and Temperature Changes in In Vitro Applications with the Laser and Their Implications for Middle Ear Surgery

    PubMed Central

    Schwab, Burkard; Kontorinis, Georgios

    2010-01-01

    Background. The purpose of this study was to evaluate the thermal and pressure effects using a Titan Sapphire chirped-pulse amplifier system configured to deliver ultrashort pulses of 180 femtoseconds (fs) in an inner ear model. Materials and Methods. Temperature increases and heat exchange processes in the fluid (physiological saline) were examined in a calorically and physiologically approximated cochlea model for applying laser parameters effective in the creation of footplate perforations. Results. In the effective energy density range, the highest temperature increases achieved with the Carbon dioxide (CO2) laser were about 11 degrees C. The lowest temperature maxima were 6 degrees C with the Er:YAG laser (Yttrium-Aluminum-Oxide doted with Erbium3+-ions) and <5 degrees C with the femtosecond laser. Comparison of the laser-induced pressure with the limit graph published by Pfander indicated that the use of the fs laser is unobjectionable for fluences <1 J/cm2. Conclusions. Our investigations demonstrated that the application of the fs laser in middle ear surgery presents a new and promising addition to the range of ultrashort wavelength lasers used for this purpose. PMID:20953354

  18. Collision-induced dissociation of aminophospholipids (PE, MMPE, DMPE, PS): an apparently known fragmentation process revisited.

    PubMed

    Pittenauer, Ernst; Rehulka, Pavel; Winkler, Wolfgang; Allmaier, Günter

    2015-07-01

    A new type of low-mass substituted 4-oxazolin product ions of [M + H](+) precursor ions of aminophospholipids (glycerophosphatidylethanolamine, glycerophosphatidyl-N-methylethanolamine, glycerophosphatidyl-N,N-dimethylethanolamine, glycerophosphatidylserine) resulting from high-energy collision-induced dissociation (matrix-assisted laser desorption/ionization time-of-flight/reflectron time-of-flight mass spectrometry) and low-energy collision-induced dissociation (e.g., electrospray ionization quadrupole reflectron time-of-flight mass spectrometry) with accurate mass determination is described; these were previously misidentified as CHO-containing radical cationic product ions. The mechanism for the formation of these ions is proposed to be via rapid loss of water followed by cyclization to an 11-membered-ring transition state for the sn-1 fatty acid substituent and to a ten-membered-ring transition state for the sn-2 fatty acid substituent, and via final loss of monoacylglycerol phosphate, leading to substituted 4-oxazolin product ions. The minimum structural requirement for this interesting skeletal rearrangement fragmentation is an amino group linked to at least one hydrogen atom (i.e., ethanolamine, N-methylethanolamine, serine). Therefore, N,N-dimethylethanolamine derivates do not exhibit this type of fragmentation. The analytical value of these product ions is given by the fact that by post source decay and particularly high-energy collision-induced dissociation achieved via matrix-assisted laser desorption/ionization time-of-flight/reflectron time-of-flight mass spectrometry, the sn-2-related substituted 4-oxazolin product ion is always significantly more abundant than the sn-1-related one, which is quite helpful for detailed structural analysis of complex lipids. All other important product ions found are described in detail (following our previously published glycerophospholipid product ion nomenclature; Pittenauer and Allmaier, Int. J. Mass. Spectrom. 301:90-1012, 2011).

  19. Laser-Induced Acoustic Desorption/Electron Ionization of Amino Acids and Small Peptides

    NASA Astrophysics Data System (ADS)

    Jarrell, Tiffany M.; Owen, Benjamin C.; Riedeman, James S.; Prentice, Boone M.; Pulliam, Chris J.; Max, Joann; Kenttämaa, Hilkka I.

    2017-06-01

    Laser-induced acoustic desorption (LIAD) allows for desorption of neutral nonvolatile compounds independent of their volatility or thermal stability. Many different ionization methods have been coupled with LIAD. Hence, this setup provides a better control over the types of ions formed than other mass spectrometry evaporation/ionization methods commonly used to characterize biomolecules, such as ESI or MALDI. In this study, the utility of LIAD coupled with electron ionization (EI) was tested for the analysis of common amino acids with no derivatization. The results compared favorably with previously reported EI mass spectra obtained using thermal desorption/EI. Further, LIAD/EI mass spectra collected for hydrochloride salts of two amino acids were found to be similar to those measured for the neutral amino acids with the exception of the appearance of an HCl+● ion. However, the hydrochloride salt of arginine showed a distinctly different LIAD/EI mass spectrum than the previously published literature EI mass spectrum, likely due to its highly basic side chain that makes a specific zwitterionic form particularly favorable. Finally, EI mass spectra were measured for seven small peptides, including di-, tri-, and tetrapeptides. These mass spectra show a variety of ion types. However, an type ions are prevalent. Also, electron-induced dissociation (EID) of protonated peptides has been reported to form primarily an type ions. In addition, the loss of small neutral molecules and side-chain cleavages were observed that are reminiscent of other high-energy fragmentation methods, such as EID. Finally, the isomeric dipeptides LG and IG were found to produce drastically different EI mass spectra, thus allowing differentiation of the leucine and isoleucine amino acids in these dipeptides. [Figure not available: see fulltext.

  20. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK).

    PubMed

    Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen

    2017-01-01

    Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of -0.75 D to 1.0 D ×175° in her right eye 1 month later. We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management.

  1. Recent Development of Sb-based Phototransistors in the 0.9- to 2.2-microns Wavelength Range for Applications to Laser Remote Sensing

    NASA Technical Reports Server (NTRS)

    Abedin, M. Nurul; Refaat, Tamer F.; Sulima, Oleg V.; Singh, Upendra N.

    2006-01-01

    We have investigated commercially available photodiodes and also recent developed Sb-based phototransistors in order to compare their performances for applications to laser remote sensing. A custom-designed phototransistor in the 0.9- to 2.2-microns wavelength range has been developed at AstroPower and characterized at NASA Langley's Detector Characterization Laboratory. The phototransistor's performance greatly exceeds the previously reported results at this wavelength range in the literature. The detector testing included spectral response, dark current and noise measurements. Spectral response measurements were carried out to determine the responsivity at 2-microns wavelength at different bias voltages with fixed temperature; and different temperatures with fixed bias voltage. Current versus voltage characteristics were also recorded at different temperatures. Results show high responsivity of 2650 A/W corresponding to an internal gain of three orders of magnitude, and high detectivity (D*) of 3.9x10(exp 11) cm.Hz(exp 1/2)/W that is equivalent to a noise-equivalent-power of 4.6x10(exp -14) W/Hz(exp 1/2) (-4.0 V @ -20 C) with a light collecting area diameter of 200-microns. It appears that this recently developed 2-micron phototransistor's performances such as responsivity, detectivity, and gain are improved significantly as compared to the previously published APD and SAM APD using similar materials. These detectors are considered as phototransistors based-on their structures and performance characteristics and may have great potential for high sensitivity differential absorption lidar (DIAL) measurements of carbon dioxide and water vapor at 2.05-microns and 1.9-microns, respectively.

  2. Solar-Pumped TEM₀₀ Mode Nd:YAG laser.

    PubMed

    Liang, Dawei; Almeida, Joana

    2013-10-21

    Here we show a significant advance in solar-pumped laser beam brightness by utilizing a 1.0 m diameter Fresnel lens and a 3 mm diameter Nd:YAG single-crystal rod. The incoming solar radiation is firstly focused by the Fresnel lens on a solar tracker. A large aspheric lens and a 2D-CPC concentrator are then combined to further compress the concentrated solar radiation along the thin laser rod within a V-shaped pumping cavity. 2.3 W cw TEM₀₀ (M² ≤ 1.1) solar laser power is finally produced, attaining 1.9 W laser beam brightness figure of merit, which is 6.6 times higher than the previous record. For multimode operation, 8.1 W cw laser power is produced, corresponding to 143% enhancement in collection efficiency.

  3. Enhancement of the design of a pulsed UV laser system for a laser-desorption mass spectrometer on Mars

    NASA Astrophysics Data System (ADS)

    Kolleck, C.; Büttner, A.; Ernst, M.; Hunnekuhl, M.; Hülsenbusch, T.; Moalem, A.; Priehs, M.; Kracht, D.; Neumann, J.

    2017-11-01

    A laser-desorption mass spectrometer will be part of the ESA-led ExoMars mission with the objective of identifying organic molecules on planet Mars. A UV laser source emitting nanosecond pulses with pulse energy of about 250 μJ at a wavelength of 266 nm is required for the ionization of nonvolatile soil constituents. A passively q-switched, diode-pumped Nd∶YAG laser oscillator with external frequency quadrupling has been developed. The basic optical concept and a previously developed flight-near prototype are redesigned for the engineering qualification model of the laser, mainly due to requirements updated during the development process and necessary system adaptations. Performance issues like pulse energy stability, pulse energy adjustment, and burst mode operation are presented in this paper.

  4. Formation of laser-induced periodic surface structures (LIPSS) on tool steel by multiple picosecond laser pulses of different polarizations

    NASA Astrophysics Data System (ADS)

    Gregorčič, Peter; Sedlaček, Marko; Podgornik, Bojan; Reif, Jürgen

    2016-11-01

    Laser-induced periodic surface structures (LIPSS) are produced on cold work tool steel by irradiation with a low number of picosecond laser pulses. As expected, the ripples, with a period of about 90% of the laser wavelength, are oriented perpendicular to the laser polarization. Subsequent irradiation with the polarization rotated by 45° or 90° results in a corresponding rotation of the ripples. This is visible already with the first pulse and becomes almost complete - erasing the previous orientation - after as few as three pulses. The phenomenon is not only observed for single-spot irradiation but also for writing long coherent traces. The experimental results strongly defy the role of surface plasmon-polaritons as the predominant key to LIPSS formation.

  5. Multi Laser Pulse Investigation of the DEAS Concept in Hypersonic Flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minucci, M.A.S.; Toro, P.G.P.; Oliveira, A.C.

    2004-03-30

    The present paper presents recent experimental results on the Laser-Supported Directed Energy 'Air Spike' - DEAS in hypersonic flow achieved by the Laboratory of Aerothermodynamics and Hypersonics - LAH, Brazil. Two CO2 TEA lasers, sharing the same optical cavity, have been used in conjunction with the IEAv 0.3m Hypersonic Shock Tunnel - HST to demonstrate the Laser-Supported DEAS concept. A single and double laser pulse, generated during the tunnel useful test time, were focused through a NaCl lens upstream of a Double Apollo Disc model fitted with seven piezoelectric pressure transducers and six platinum thin film heat transfer gauges. Themore » objective being to corroborate previous results as well as to obtain additional pressure and heat flux distributions information when two laser pulses are used.« less

  6. Comparison of four different lasers for acne scars: Resurfacing and fractional lasers.

    PubMed

    You, Hi-Jin; Kim, Deok-Woo; Yoon, Eul-Sik; Park, Seung-Ha

    2016-04-01

    Acne scars are common and cause cosmetic problems. There is a multitude of treatment options for acne scars, including dermabrasion, chemical peeling, and fillers, but the advent of laser technology has greatly improved the treatment of acne scars. Although several laser systems are available, studies comparing their efficacy are limited. This study compares the results of treatments using resurfacing (carbon dioxide, CO2; erbium-doped yttrium aluminum garnet, Er:YAG) versus fractional (nonablative fractional laser, NAFL; ablative fractional laser, AFL) lasers. A retrospective photographic analysis of 58 patients who underwent laser treatment for facial atrophic acne scars was performed. Clinical improvement was assessed by six blinded investigators with a scale graded from 0 to 10. Adverse events were also noted. Mean improvement scores of the CO2, Er:YAG, NAFL, and AFL groups were 6.0, 5.8, 2.2, and 5.2, respectively. The NAFL group showed a significantly lower score than the other groups. The mean number of treatments was significantly greater in the fractional laser groups than in the resurfacing laser groups. The resurfacing laser groups had a prolonged recovery period and high risk of complications. The Er:YAG laser caused less erythema or pigmentation compared to the CO2 laser. Although the CO2 laser, Er:YAG laser, and AFL improved the acne scars, the CO2 laser had a greater downtime. Three consecutive AFL treatments are as effective as a single treatment with resurfacing lasers, with shorter social downtime periods and less adverse effects. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harilal, Sivanandan S.; Brumfield, Brian E.; LaHaye, Nicole L.

    2018-04-20

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  8. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE PAGES

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.; ...

    2018-04-20

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Lastly, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  9. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  10. [Issues of provision of the safety of laserwares in the use of nanotechnologies].

    PubMed

    Pal'tsevIu P; Levina, A V; Kravchenko, O K

    2008-01-01

    Current technologies, including nanotechnologies, cannot be introduced, without applying laser equipment. For provision of the safety in the manufacture and use of up-to-date laser equipment that is characterized by new, previously unused wavelengths and exposure levels, it is necessary to develop the hygienic regulation of the arrangement and maintenance of lasers, to improve approaches to making their sanitary-and-epidemiological examination and manufacturing inspection, to design measuring instruments that permit an objective assessment of new types of laser exposures, and to develop the current means for protecting the organ of vision in service personnel.

  11. Laser-welded Dissimilar Steel-aluminum Seams for Automotive Lightweight Construction

    NASA Astrophysics Data System (ADS)

    Schimek, M.; Springer, A.; Kaierle, S.; Kracht, D.; Wesling, V.

    By reducing vehicle weight, a significant increase in fuel efficiency and consequently a reduction in CO 2 emissions can be achieved. Currently a high interest in the production of hybrid weld seams between steel and aluminum exists. Previous methods as laser brazing are possible only by using fluxes and additional materials. Laser welding can be used to join steel and aluminum without the use of additives. With a low penetration depth increases in tensile strength can be achieved. Recent results from laser welded overlap seams show that there is no compromise in strength by decreasing penetration depth in the aluminum.

  12. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Lastly, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  13. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE PAGES

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.; ...

    2018-06-01

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  14. Laser machining wood composites

    Treesearch

    Vladimir Barnekov; Henry A. Huber; Charles W. McMillin

    1989-01-01

    This practical, nonstatistical experiment using commercial equipment demonstrated that nominal 3/4-inch compositep anelsf or furniture consisting of a particleboard core,h igh density melamine crossbands, and walnut veneer face plies can be cut with a carbon dioxide/airjet-assisted laser to produce surfaces with minimal nonparallelism and char compared to previous...

  15. Excellent Aesthetic and Functional Outcome After Fractionated Carbon Dioxide Laser Skin Graft Revision Surgery: Case Report and Review of Laser Skin Graft Revision Techniques.

    PubMed

    Ho, Derek; Jagdeo, Jared

    2015-11-01

    Skin grafts are utilized in dermatology to reconstruct a defect secondary to surgery or trauma of the skin. Common indications for skin grafts include surgical removal of cutaneous malignancies, replacement of tissue after burns or lacerations, and hair transplantation in alopecia. Skin grafts may be cosmetically displeasing, functionally limiting, and significantly impact patient's quality-of-life. There is limited published data regarding skin graft revision to enhance aesthetics and function. Here, we present a case demonstrating excellent aesthetic and functional outcome after fractionated carbon dioxide (CO2) laser skin graft revision surgery and review of the medical literature on laser skin graft revision techniques.

  16. Long-term remission of folliculitis decalvans after treatment with the long-pulsed Nd:YAG laser.

    PubMed

    Meesters, Arne A; Van der Veen, J P Wietze; Wolkerstorfer, Albert

    2014-04-01

    Folliculitis decalvans (FD) is a rare inflammatory scalp disorder presenting with tufted folliculitis, follicular papules and pustules, progressing to cicatricial alopecia. Current treatments mainly consist of antibiotic and immunomodulatory therapies and are often disappointing. FD has previously shown to respond to treatment with neodymium:yttrium aluminium garnet (Nd:YAG) laser in one case. We present a case of recalcitrant FD, successfully treated with a long-pulsed Nd:YAG laser.

  17. Bit Error Ratio Test Equipment for High Speed Vertical Cavity Transistor Laser and MicroCavity VCSEL and Photo Receiver

    DTIC Science & Technology

    2015-08-31

    Ratio Test Equipment for High Speed Vertical Cavity Transistor Laser & MicroCavity VCSEL and Photo Receiver The views, opinions and/or findings...suggesstions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis...for High Speed Vertical Cavity Transistor Laser & MicroCavity VCSEL and Photo Receiver Report Title In the previous DURIP award (W911NF-13-1-0287

  18. The effect of static cyclotorsion compensation on refractive and visual outcomes using the Schwind Amaris laser platform for the correction of high astigmatism.

    PubMed

    Aslanides, Ioannis M; Toliou, Georgia; Padroni, Sara; Arba Mosquera, Samuel; Kolli, Sai

    2011-06-01

    To compare the refractive and visual outcomes using the Schwind Amaris excimer laser in patients with high astigmatism (>1D) with and without the static cyclotorsion compensation (SCC) algorithm available with this new laser platform. 70 consecutive eyes with ≥1D astigmatism were randomized to treatment with compensation of static cyclotorsion (SCC group- 35 eyes) or not (control group- 35 eyes). A previously validated optimized aspheric ablation algorithm profile was used in every case. All patients underwent LASIK with a microkeratome cut flap. The SCC and control group did not differ preoperatively, in terms of refractive error, magnitude of astigmatism or in terms of cardinal or oblique astigmatism. Following treatment, average deviation from target was SEq +0.16D, SD±0.52 D, range -0.98 D to +1.71 D in the SCC group compared to +0.46 D, SD±0.61 D, range -0.25 D to +2.35 D in the control group, which was statistically significant (p<0.05). Following treatment, average astigmatism was 0.24 D (SD±0.28 D, range -1.01 D to 0.00 D) in the SCC group compared to 0.46 D (SD±0.42 D, range -1.80 D to 0.00 D) in the control group, which was highly statistically significant (p<0.005). There was no statistical difference in the postoperative uncorrected vision when the aspheric algorithm was used although there was a trend to increased number of lines gained in the SCC group. This study shows that static cyclotorsion is accurately compensated for by the Schwind Amaris laser platform. The compensation of static cyclotorsion in patients with moderate astigmatism produces a significant improvement in refractive and astigmatic outcomes than when not compensated. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Higher Order Chemistry Models in the CFD Simulation of Laser-Ablated Carbon Plumes

    NASA Technical Reports Server (NTRS)

    Greendyke, R. B.; Creel, J. R.; Payne, B. T.; Scott, C. D.

    2005-01-01

    Production of single-walled carbon nanotubes (SWNT) has taken place for a number of years and by a variety of methods such as laser ablation, chemical vapor deposition, and arc-jet ablation. Yet, little is actually understood about the exact chemical kinetics and processes that occur in SWNT formation. In recent time, NASA Johnson Space Center has devoted a considerable effort to the experimental evaluation of the laser ablation production process for SWNT originally developed at Rice University. To fully understand the nature of the laser ablation process it is necessary to understand the development of the carbon plume dynamics within the laser ablation oven. The present work is a continuation of previous studies into the efforts to model plume dynamics using computational fluid dynamics (CFD). The ultimate goal of the work is to improve understanding of the laser ablation process, and through that improved understanding, refine the laser ablation production of SWNT.

  20. Formation of high mass carbon cluster ions from laser ablation of polymers and thin carbon films

    NASA Astrophysics Data System (ADS)

    Creasy, William R.; Brenna, J. T.

    1990-02-01

    Three materials were studied by laser ablation/Fourier transform mass spectrometry, using 266 nm laser radiation: a copolymer of ethylene and tetrafluoroethylene (ETFE), polyphenylene sulfide (PPS), and a diamond-like carbon film (DLC). In each case, positive ion mass spectra exhibit primarily even-numbered, high mass carbon clusters (``fullerenes'') of the type previously reported for graphite ablation. In the case of ETFE, a large C+60 peak (``buckminsterfullerene'') was observed. The polymer spectra showed a strong dependence on the number of laser pulses on one spot and the laser power density. For ETFE, the fullerene ion relative intensity first increases and then decreases as a function of the number of laser pulses. For the DLC film, fullerenes are observed with a single laser pulse on a fresh spot of the sample. The results are interpreted in terms of a gas phase growth model for the fullerene ion formation.

  1. Dependence of optimal initial density on laser parameters for multi-keV x-ray radiators generated by nanosecond laser-produced underdense plasma

    NASA Astrophysics Data System (ADS)

    Tu, Shao-yong; Yuan, Yong-teng; Hu, Guang-yue; Miao, Wen-yong; Zhao, Bin; Zheng, Jian; Jiang, Shao-en; Ding, Yong-kun

    2016-01-01

    Efficient multi-keV x-ray sources can be produced using nanosecond laser pulse-heated middle-Z underdense plasmas generated using gas or foam. Previous experimental results show that an optimal initial target density exists for efficient multi-keV x-ray emission at which the laser ionization wave is supersonic. Here we explore the influence of the laser intensity and the pulse duration on this optimal initial target density via a one-dimensional radiation hydrodynamic simulation. The simulation shows that the optimal initial density is sensitive to both the laser intensity and the pulse duration. However, the speed of the supersonic ionization wave at the end of the laser irradiation is always maintained at 1.5 to 1.7 times that of the ion acoustic wave under the optimal initial density conditions.

  2. Effects of Different Polarization Strategies on Laser Cutting with Direct Diode Lasers

    NASA Astrophysics Data System (ADS)

    Rodrigues, G. Costa; Duflou, J. R.

    As Direct Diode Lasers are introduced as an emerging technology for laser cutting of metal sheets, new challenges arise. The relatively low beam quality remains a limitation to the maximum cutting speed. One way to balance this may be a strategic use of laser polarization in order to influence laser material interaction in the cutting kerf. In this paper the effects of cross-, linear-, radial- and azimuthal- laser beam polarization arrangements are studied with both Fusion and Flame cutting at an output power of approximately 750W. Different combinations of materials and thicknesses were cut and the maximum cutting speed and edge quality analyzed. It is found that at similar cutting edge quality, improvements in cutting speed can go up to 40% with an inert gas, such as Nitrogen, and up to 20% with a reactive gas, such as Oxygen, in agreement with analytical models for absorption previously developed by the authors.

  3. Laser ablation efficiency during the production of Ag nanoparticles in ethanol at a low pulse repetition rate (1-10 Hz)

    NASA Astrophysics Data System (ADS)

    Valverde-Alva, M. A.; García-Fernández, T.; Esparza-Alegría, E.; Villagrán-Muniz, M.; Sánchez-Aké, C.; Castañeda-Guzmán, R.; de la Mora, M. B.; Márquez-Herrera, C. E.; Sánchez Llamazares, J. L.

    2016-10-01

    We studied the effect of the repetition rate of laser pulses (RRLP) in the range from 1-10 Hz in the production of silver nanoparticles (Ag-NPs) by laser ablation in ethanol. Laser pulses with a duration of 7 ns, a wavelength of 1064 nm and an energy of 60 mJ were used to ablate a 99.99% pure silver target immersed in 10 ml of ethanol. Transmittance analysis and atomic absorption spectroscopy were used to study the silver concentration in the colloidal solutions. The ablation process was studied by measuring the transmission of the laser pulses through the colloid. It is shown that for a fixed number of laser pulses (NLP) the ablation efficiency, in terms of the ablated silver mass per laser pulse, increases with the RRLP. This result contradicts what had previously been established in the literature.

  4. Simulation of laser-tattoo pigment interaction in a tissue-mimicking phantom using Q-switched and long-pulsed lasers.

    PubMed

    Ahn, K J; Kim, B J; Cho, S B

    2017-08-01

    Laser therapy is the treatment of choice in tattoo removal. However, the precise mechanisms of laser-tattoo pigment interactions remain to be evaluated. We evaluated the geometric patterns of laser-tattoo pigment particle interactions using a tattoo pigment-embedded tissue-mimicking (TM) phantom. A Q-switched (QS) neodymium-doped yttrium aluminum garnet laser was used at settings of 532-, 660-, and 1064-nm wavelengths, single-pulse and quick pulse-to-pulse treatment modes, and spot sizes of 4 and 7 mm. Most of the laser-tattoo interactions in the experimental conditions formed cocoon-shaped or oval photothermal and photoacoustic injury zones, which contained fragmented tattoo particles in various sizes depending on the conditions. In addition, a long-pulsed 755-nm alexandrite laser was used at a spot size of 6 mm and pulse widths of 3, 5, and 10 ms. The finer granular pattern of tattoo destruction was observed in TM phantoms treated with 3- and 5-ms pulse durations compared to those treated with a 10-ms pulse. We outlined various patterns of laser-tattoo pigment interactions in a tattoo-embedded TM phantom to predict macroscopic tattoo and surrounding tissue reactions after laser treatment for tattoo removal. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Antihyperglycaemic effect of laser acupuncture treatment at BL20 in diabetic rats.

    PubMed

    Cornejo-Garrido, Jorge; Becerril-Chávez, Flavia; Carlín-Vargas, Gabriel; Ordoñez-Rodríguez, Juan Manuel; Abrajan-González, María Del Carmen; de la Cruz-Ramírez, Rosario; Ordaz-Pichardo, Cynthia

    2014-12-01

    To investigate the antihyperglycaemic activity of laser acupuncture stimulation at 650 and 980 nm at BL20 in streptozotocin (STZ)-induced diabetic rats. Seventy healthy adult male albino Wistar rats weighing 250±50 g were divided into seven groups of 10 animals each. Groups I-III comprised healthy control rats which were untreated (I) or stimulated with laser acupuncture at 650 nm (II) and 980 nm (III), respectively. Groups IV-VII underwent induction of diabetes with a single intraperitoneal administration of STZ at 50 mg/kg. Animals with blood glucose levels of ≥200 mg/dL on the fifth day were used for the experiments and were left untreated (group IV), treated with glibenclamide (group V) or stimulated with laser acupuncture at 650 nm (group VI) and 980 nm (group VII), respectively. Laser acupuncture was applied at BL20 on alternate days for a total of 12 sessions over a 28-day period. After 28 days of treatment, STZ-induced diabetic rats stimulated with laser acupuncture at 650 and 980 nm had significantly lower glucose levels compared with untreated diabetic rats (242.0±65.0 and 129.8±33.2 vs 376.5±10.0 mg/dL, both p≤0.05). Treatment at 980 nm also attenuated the increase in glucose between day 1 and day 28 compared with the glibenclamide-treated diabetic group (41.5±19.6 mg/dL vs 164.1±13.7 g/dL, p<0.05). Laser acupuncture treatment did not affect the blood count or biochemical profile and was not associated with any morphological changes in the pancreas, liver, kidney or spleen. Stimulation with laser acupuncture at 650 and 980 nm at BL20 in STZ-induced diabetic rats has antihyperglycaemic activity. The results support further evaluation of laser acupuncture as an alternative or complementary treatment for the control of hyperglycaemia. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Laser use and safety.

    PubMed

    1992-09-01

    This Guidance Article is an update of an article published in a special issue of Health Devices entitled "Lasers in Medicine--An Introduction" (13[8], June 1984). Although surgical lasers have a good overall safety record, they do expose patients, physicians, and other clinical staff to serious risks. Laser hazards can cause injury, disability, or even death: hospital staff have been burned by misdirected laser beams, technicians and maintenance personnel have received eye injuries while working on lasers and have been exposed to hazardous chemicals while changing laser dyes, and patients have died from injuries resulting from fires ignited by laser energy. Laser accidents most commonly result from misdirection of the laser beam. Direct or reflected radiation can burn skin, hair, or, more seriously, the cornea or retina, causing permanent damage. Misdirected laser energy can also cause ignition of surgical drapes, tracheal tubes, or the patient's hair. Also, a frequent by-product of laser-tissue interactions is laser plume, or smoke. Its acrid smell and particulate matter irritate the eyes, nose, and lungs and cause nausea; it is also a suspected vector for transmitting infectious materials, such as the human papilloma virus (HPV) associated with condyloma (a wartlike lesion) and cervical cancer. The risks are not limited to patients and those directly involved in using and maintaining lasers. Many laser procedures are performed in areas outside the controlled environment of the surgical suite; patients in a waiting area or even passersby could conceivably walk into an accessible laser treatment room, such as a doctor's office, and inadvertently be exposed to a direct or reflected beam.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Measurements of density, temperature, and their fluctuations in turbulent supersonic flow using UV laser spectroscopy

    NASA Technical Reports Server (NTRS)

    Fletcher, Douglas G.; Mckenzie, R. L.

    1992-01-01

    Nonintrusive measurements of density, temperature, and their turbulent fluctuation levels were obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment are compared with previous measurements obtained in the same facility using conventional probes and an earlier spectroscopic technique. Densities and temperatures measured with the current technique agree with the previous surveys to within 3 percent and 2 percent, respectively. The fluctuation amplitudes for both variables agree with the measurements obtained using the earlier spectroscopic technique and show evidence of an unsteady, weak shock wave that perturbs the boundary layer.

  8. Ocular pulse amplitude after panretinal photocoagulation in normotensive eyes with proliferative diabetic retinopathy.

    PubMed

    Bozic, Marija M; Karadzic, Jelena B; Kovacevic, Igor M; Marjanovic, Ivan S

    2017-06-26

    To assess the effect of panretinal laser photocoagulation on ocular pulse amplitude (OPA) in normotensive eyes with proliferative diabetic retinopathy. Prospectively, we performed unilateral argon laser panretinal photocoagulation (PRP) in 30 patients with diabetes mellitus type II and previously untreated bilateral proliferative diabetic retinopathy. Before and 7 and 30 days after the treatment, OPA was measured using dynamic contour tonometer. Compared with the untreated contralateral eyes, laser photocoagulation led to a reduction of OPA. Ocular pulse amplitude did not significantly differ in photocoagulated eyes 7 days after the treatment, but there was a significant difference in OPA 30 days after the treatment. The decrease in OPA values was 15% 7 days after PRP and 40% 30 days after PRP. Ocular pulse amplitude reduction after PRP indirectly informs us about choriocapillary closure, already reported in previous studies.

  9. Stable TEM00-mode Nd:YAG solar laser operation by a twisted fused silica light-guide

    NASA Astrophysics Data System (ADS)

    Bouadjemine, R.; Liang, D.; Almeida, J.; Mehellou, S.; Vistas, C. R.; Kellou, A.; Guillot, E.

    2017-12-01

    To improve the output beam stability of a TEM00-mode solar-pumped laser, a twisted fused silica light-guide was used to achieve uniform pumping along a 3 mm diameter and 50 mm length Nd:YAG rod. The concentrated solar power at the focal spot of a primary parabolic mirror with 1.18 m2 effective collection area was efficiently coupled to the entrance aperture of a 2D-CPC/2V-shaped pump cavity, within which the thin laser rod was pumped. Optimum solar laser design parameters were found through ZEMAX© non-sequential ray-tracing and LASCAD© laser cavity analysis codes. 2.3 W continuous-wave TEM00-mode 1064 nm laser power was measured, corresponding to 1.96 W/m2 collection efficiency and 2.2 W laser beam brightness figure of merit. Excellent TEM00-mode laser beam profile at M2 ≤ 1.05 and very good output power stability of less than 1.6% were achieved. Heliostat orientation error dependent laser power variation was considerably less than previous solar laser pumping schemes.

  10. Toward a comprehensive UV laser ablation modeling of multicomponent materials—A non-equilibrium investigation on titanium carbide

    NASA Astrophysics Data System (ADS)

    Ait Oumeziane, Amina; Parisse, Jean-Denis

    2018-05-01

    Titanium carbide (TiC) coatings of great quality can be produced using nanosecond pulsed laser deposition (PLD). Because the deposition rate and the transfer of the target stoichiometry depend strongly on the laser-target/laser-plasma interaction as well as the composition of the laser induced plume, investigating the ruling fundamental mechanisms behind the material ablation and the plasma evolution in the background environment under PLD conditions is essential. This work, which extends previous investigations dedicated to the study of nanosecond laser ablation of pure target materials, is a first step toward a comprehensive non-equilibrium model of multicomponent ones. A laser-material interaction model coupled to a laser-plasma interaction one is presented. A UV 20 ns KrF (248 nm) laser pulse is considered. Ablation depths, plasma ignition thresholds, and shielding rates have been calculated for a wide range of laser beam fluences. A comparison of TiC behavior with pure titanium material under the same conditions is made. Plasma characteristics such as temperature and composition have been investigated. An overall correlation between the various results is presented.

  11. International Laser Ranging Service (ILRS) 1999 Annual Report

    NASA Technical Reports Server (NTRS)

    Pearlman, Michael (Editor); Taggert, Linda (Editor)

    2000-01-01

    This 1999 Annual Report of the International Laser Ranging Service (ILRS) is comprised of individual contributions from ILRS components within the international geodetic community. This report documents the work of the ILRS components from the inception of the Service through December 31,1999. Since the service has only recently been established, the ILRS associates decided to publish this Annual report as a reference to our organization and its components.

  12. Research on Acoustical Scattering, Diffraction Catastrophes, Optics of Bubbles, Photoacoustics, and Acoustical Phase Conjugation.

    DTIC Science & Technology

    1987-09-15

    optical levitation of bubbles; D. Acoustical and optical diffraction catastrophes (theory and optical simulation of transverse cusps, experiments with...35 C. Optical Levitation of Bubbles in Water by the Radiation Pressure of a Laser Beam: An Acoustically Quiet Levitator ...radiation pressure of a laser beam: an acoustically quiet levitator ," J. Acoust . Soc. Am. (submitted July 1987). C. Books (and sections thereof) Published

  13. A comparative study of colour and perfusion between two different post surgical scars. Do the laser Doppler imager and the colorimeter measure the same features of a scar?

    PubMed

    Mermans, J F; Peeters, W J; Dikmans, R; Serroyen, J; van der Hulst, R R J W; Van den Kerckhove, E

    2013-05-01

    The purpose of this study was to investigate the influence of different located post surgical scars on both perfusion and redness. The pattern of change and correlation between perfusion and redness of post surgical scars is also examined. In this study, we measured redness and perfusion of the abdominal and breast scar of 24 women undergoing breast reconstruction with Deep Inferior Epigastric Perforator Free Flap surgery with the Minolta Chromameter CR-400/410 and the Moor Instruments laser Doppler imager 12IR, respectively, at different intervals post-operatively. The laser Doppler imager gives significantly higher values for the abdominal compared with the breast scar. There was no consistent correlation found between perfusion and redness at the different test moments for both locations. The scores of both parameters were significantly associated after 9 months follow-up for both locations. Scars closed with higher mechanical force show higher perfusion and prolonged activity; and more redness is associated with more perfusion for both post surgical scars. Nevertheless, there was no consistent correlation found between these parameters making the laser Doppler imager and the Colorimeter still non-replaceable instruments. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  14. Laser-shocked energetic materials with metal additives: evaluation of detonation performance

    NASA Astrophysics Data System (ADS)

    Gottfried, Jennifer; Bukowski, Eric

    A focused, nanosecond-pulsed laser with sufficient energy to exceed the breakdown threshold of a material generates a laser-induced plasma with high peak temperatures, pressures, and shock velocities. Depending on the laser parameters and material properties, nanograms to micrograms of material is ablated, atomized, ionized and excited in the laser-induced plasma. The subsequent shock wave expansion into the air above the sample has been monitored using high-speed schlieren imaging in a recently developed technique, laser-induced air shock from energetic materials (LASEM). The estimated detonation velocities using LASEM agree well with published experimental values. A comparison of the measured shock velocities for various energetic materials including RDX, DNTF, and LLM-172 doped with Al or B to the detonation velocities predicted by CHEETAH for inert or active metal participation demonstrates that LASEM has potential for predicting the early time participation of metal additives in detonation events. The LASEM results show that reducing the amount of hydrogen present in B formulations increases the resulting detonation velocities

  15. Femtosecond laser induced fixation of calcium alkali phosphate ceramics on titanium alloy bone implant material.

    PubMed

    Symietz, Christian; Lehmann, Erhard; Gildenhaar, Renate; Krüger, Jörg; Berger, Georg

    2010-08-01

    Femtosecond lasers provide a novel method of attaching bioceramic material to a titanium alloy, thereby improving the quality of bone implants. The ultrashort 30 fs laser pulses (790 nm wavelength) penetrate a thin dip-coated layer of fine ceramic powder, while simultaneously melting a surface layer of the underlying metal. The specific adjustment of the laser parameters (pulse energy and number of pulses per spot) avoids unnecessary melting of the bioactive calcium phosphate, and permits a defined thin surface melting of the metal, which in turn is not heated throughout, and therefore maintains its mechanical stability. It is essential to choose laser energy densities that correspond to the interval between the ablation fluences of both materials involved: about 0.1-0.4 Jcm(-2). In this work, we present the first results of this unusual technique, including laser ablation studies, scanning electron microscopy and optical microscope images, combined with EDX data. Copyright 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Review of photorejuvenation: devices, cosmeceuticals, or both?

    PubMed

    Rokhsar, Cameron K; Lee, Sandra; Fitzpatrick, Richard E

    2005-09-01

    Both the public and the medical profession have placed a lot of attention on reversal of signs of aging and photodamage, resulting in numerous cosmeceutical products and nonablative laser techniques designed to achieve these results. The purpose of this report is to briefly review both the cosmeceutical products and nonablative laser techniques that appear to be most promising based on published studies. After this review, recommendations for potential enhancement of benefits by combining cosmeceuticals and laser treatments will be explored. Pulsed dye lasers targeting microvessels, intense pulsed light targeting both melanin and microvessels, and midinfrared lasers targeting dermal water and collagen all appear to have some ability to improve skin texture, color, and wrinkling. Retinoids, vitamin C, alpha-hydroxy acids, and topical growth factors may also stimulate repair mechanisms that result in similar improvements in photodamaged skin. Although supported only by theoretic considerations and anecdotal reports, it seems logical that the concurrent use of appropriate cosmeceuticals with nonablative laser photorejuvenation should result in enhanced benefits.

  17. A systematic review of the use of lasers for the treatment of hidradenitis suppurativa.

    PubMed

    John, Hannah; Manoloudakis, Nikolaos; Stephen Sinclair, J

    2016-10-01

    To conduct a systematic review of the effectiveness of various types of lasers (and light based therapies) for the treatment of hidradenitis suppurativa (HS) and to establish recommendations based on our findings. MEDLINE, Cochrane and PubMed databases. English language studies describing the use of laser for the treatment of HS. Multiple reviewers performed independent extraction and identified 22 studies that met the inclusion and exclusion criteria. Studies were categorised according to grading recommendations based on evidence quality guidelines for systematic reviews. Only 2 studies met criteria to be assigned the highest grade. Nd:YAG laser has been shown to be effective for the treatment of HS, as is intense pulsed light therapy (IPL) using the same principles of laser hair removal. There is weak evidence to recommend the use of carbon dioxide, diode or alexandrite lasers. The need for larger randomized controlled trials is highlighted. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Experimental study and finite element analysis based on equivalent load method for laser ultrasonic measurement of elastic constants.

    PubMed

    Zhan, Yu; Liu, Changsheng; Zhang, Fengpeng; Qiu, Zhaoguo

    2016-07-01

    The laser ultrasonic generation of Rayleigh surface wave and longitudinal wave in an elastic plate is studied by experiment and finite element method. In order to eliminate the measurement error and the time delay of the experimental system, the linear fitting method of experimental data is applied. The finite element analysis software ABAQUS is used to simulate the propagation of Rayleigh surface wave and longitudinal wave caused by laser excitation on a sheet metal sample surface. The equivalent load method is proposed and applied. The pulsed laser is equivalent to the surface load in time and space domain to meet the Gaussian profile. The relationship between the physical parameters of the laser and the load is established by the correction factor. The numerical solution is in good agreement with the experimental result. The simple and effective numerical and experimental methods for laser ultrasonic measurement of the elastic constants are demonstrated. Copyright © 2016. Published by Elsevier B.V.

  19. Novel Treatment Approach for Deep Palmoplantar Warts Using Long-Pulsed 1064-nm Nd:YAG Laser and a Moisturizing Cream Without Prior Paring of the Wart Surface.

    PubMed

    Alshami, Mohammad Ali; Mohana, Mona Jameel

    2016-10-01

    The present study aimed to assess the safety and efficacy of palmoplantar wart removal using long-pulsed 1064-nm Nd:YAG laser after application of a moisturizing cream. Previously described laser treatments for wart removal are associated with negative side effects and need to pare the warts before laser treatment. Two hundred forty patients (142 males, 98 females) were treated for 1-40 palmoplantar warts by long-pulsed 1064-nm Nd:YAG laser (spot size 4-6 mm, pulse duration 20 msec, fluence 200 J/cm 2 ) after covering the wart surface with a thin film of a moisturizing cream. The endpoint was lesion graying or whitening with or without development of a hemorrhagic bulla beneath the treated wart. Color photographs were taken before and immediately after each laser session and at 1, 4, and 16 weeks after the last session. The overall clearance rate was 97%, with 90% of treated patients cured after one session, 4% after two, and 3% after three. Clearance rate after three laser sessions decreased linearly with the number of warts from 100% to 95%. Less accessible wart location in interdigital spaces also decreased the cure rate after three sessions from 100% to 95%. Additionally, warts became more difficult to eradicate as they aged. Remission lasted up to 6 years, and complications were mild and infrequent (17.5%). This novel method is effective in removing palmoplantar warts. It is easier, time-saving, and safer than other methods described in previous studies conducted with ablative or nonablative lasers.

  20. Direct solar-pumped iodine laser amplifier

    NASA Technical Reports Server (NTRS)

    Han, Kwang S.; Hwang, In Heon; Stock, Larry V.

    1989-01-01

    This semiannual progress report covers the period from September 1, 1988 to February 28, 1989 under NASA grant NAG-1-441 entitled, Direct Solar-Pumped Iodine Laser Amplifier. During this period, the research effort was concentrated on the solar pumped master oscillator power amplifier (MOPA) system using n-C3F7I. In the experimental work, the amplification measurement was conducted to identify the optimum conditions for amplification of the center's Vortek solar simulator pumped iodine laser amplifier. A modeling effort was also pursued to explain the experimental results in the theoretical work. The amplification measurement of the solar simulator pumped iodine laser amplifier is the first amplification experiment on the continuously pumped amplifier. The small signal amplification of 5 was achieved for the triple pass geometry of the 15 cm long solar simulator pumped amplifier at the n-C3F7I pressure of 20 torr, at the flow velocity of 6 m/sec and at the pumping intensity of 1500 solar constants. The XeCl laser pumped iodine laser oscillator, which was developed in the previous research, was employed as the master oscillator for the amplification measurement. In the theoretical work, the rate equations of the amplifier was established and the small signal amplification was calculated for the solar simulator pumped iodine laser amplifier. The amplification calculated from the kinetic equations with the previously measured rate coefficients reveals very large disagreement with experimental measurement. Moreover, the optimum condition predicted by the kinetic equation is quite discrepant with that measured by experiment. This fact indicates the necessity of study in the measurement of rate coefficients of the continuously pumped iodine laser system.

  1. The relative importance of fluid and kinetic frequency shifts of an electron plasma wave

    NASA Astrophysics Data System (ADS)

    Winjum, B. J.; Fahlen, J.; Mori, W. B.

    2007-10-01

    The total nonlinear frequency shift of a plasma wave including both fluid and kinetic effects is estimated when the phase velocity of the wave is much less than the speed of light. Using a waterbag or fluid model, the nonlinear frequency shift due to harmonic generation is calculated for an arbitrary shift in the wavenumber. In the limit where the wavenumber does not shift, the result is in agreement with previously published work [R. L. Dewar and J. Lindl, Phys. Fluids 15, 820 (1972); T. P. Coffey, Phys. Fluids 14, 1402 (1971)]. This shift is compared to the kinetic shift of Morales and O'Neil [G. J. Morales and T. M. O'Neil, Phys. Rev. Lett. 28, 417 (1972)] for wave amplitudes and values of kλD of interest to Raman backscatter of a laser driver in inertial confinement fusion.

  2. High Sensitivity Analysis of Nanoliter Volumes of Volatile and Nonvolatile Compounds using Matrix Assisted Ionization (MAI) Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Hoang, Khoa; Pophristic, Milan; Horan, Andrew J.; Johnston, Murray V.; McEwen, Charles N.

    2016-10-01

    First results are reported using a simple, fast, and reproducible matrix-assisted ionization (MAI) sample introduction method that provides substantial improvements relative to previously published MAI methods. The sensitivity of the new MAI methods, which requires no laser, high voltage, or nebulizing gas, is comparable to those reported for MALDI-TOF and n-ESI. High resolution full acquisition mass spectra having low chemical background are acquired from low nanoliters of solution using only a few femtomoles of analyte. The limit-of-detection for angiotensin II is less than 50 amol on an Orbitrap Exactive mass spectrometer. Analysis of peptides, including a bovine serum albumin digest, and drugs, including drugs in urine without a purification step, are reported using a 1 μL zero dead volume syringe in which only the analyte solution wetting the walls of the syringe needle is used in the analysis.

  3. Detection of adulterants in honey using a portable Raman Spectrometer

    NASA Astrophysics Data System (ADS)

    Garcia, Kenneth Leigh

    Food adulteration is a growing problem worldwide. In the United States over half of honey consumed is provided with imported products as total domestic production of honey is unable to meet the demand. As pure, natural honey is a labor intensive, relatively expensive product it is a prime target for adulteration with less expensive sweeteners. Previously published work describes the detection of these adulterants in a strict laboratory environment with time consuming techniques and delicate instrumentation. Experiments confirm that adulterants such as high fructose corn syrup and rice malt syrup can be detected in honey using Raman Spectroscopy and portable equipment. When laser light is applied to the products, the result is a Raman signal of inelastically scattered photons representing the fingerprints of the various molecules. When this signal is detected and stored in a laptop computer it can be analyzed for characteristics peculiar to honey and to the adulterants.

  4. Multi-frequency local wavenumber analysis and ply correlation of delamination damage.

    PubMed

    Juarez, Peter D; Leckey, Cara A C

    2015-09-01

    Wavenumber domain analysis through use of scanning laser Doppler vibrometry has been shown to be effective for non-contact inspection of damage in composites. Qualitative and semi-quantitative local wavenumber analysis of realistic delamination damage and quantitative analysis of idealized damage scenarios (Teflon inserts) have been performed previously in the literature. This paper presents a new methodology based on multi-frequency local wavenumber analysis for quantitative assessment of multi-ply delamination damage in carbon fiber reinforced polymer (CFRP) composite specimens. The methodology is presented and applied to a real world damage scenario (impact damage in an aerospace CFRP composite). The methodology yields delamination size and also correlates local wavenumber results from multiple excitation frequencies to theoretical dispersion curves in order to robustly determine the delamination ply depth. Results from the wavenumber based technique are validated against a traditional nondestructive evaluation method. Published by Elsevier B.V.

  5. Picosecond lasers: the next generation of short-pulsed lasers.

    PubMed

    Freedman, Joshua R; Kaufman, Joely; Metelitsa, Andrea I; Green, Jeremy B

    2014-12-01

    Selective photothermolysis, first discussed in the context of targeted microsurgery in 1983, proposed that the optimal parameters for specific thermal damage rely critically on the duration over which energy is delivered to the tissue. At that time, nonspecific thermal damage had been an intrinsic limitation of all commercially available lasers, despite efforts to mitigate this by a variety of compensatory cooling mechanisms. Fifteen years later, experimental picosecond lasers were first reported in the dermatological literature to demonstrate greater efficacy over their nanosecond predecessors in the context of targeted destruction of tattoo ink. Within the last 4 years, more than a decade after those experiments, the first commercially available cutaneous picosecond laser unit became available (Cynosure, Westford, Massachusetts), and several pilot studies have demonstrated its utility in tattoo removal. An experimental picosecond infrared laser has also recently demonstrated a nonthermal tissue ablative capability in soft tissue, bone, and dentin. In this article, we review the published data pertaining to dermatology on picosecond lasers from their initial reports to the present as well as discuss forthcoming technology.

  6. Anaesthesia modalities during laser photocoagulation for retinopathy of prematurity: a retrospective, longitudinal study.

    PubMed

    Jiang, Jing-Bo; Strauss, Randy; Luo, Xian-Qiong; Nie, Chuan; Wang, Yan-Li; Zhang, Jia-Wen; Zhang, Zhi-Wei

    2017-01-24

    Laser photocoagulation surgery is a routine treatment for threshold retinopathy of prematurity (ROP). However, little is known about which anaesthesia protocols provide efficient pain control while minimising exposure risk to vulnerable infants. In this study, therefore, we assessed the efficacy and tolerability of multiple anaesthesia techniques used on premature infants during laser therapy. Anaesthesia modalities consisted of topical eye drops anaesthesia, general anaesthesia and intravenous fentanyl sedation with mechanical ventilation. Laser treatment efficacy and detailed operative information were retrospectively and consecutively analysed. Cardiorespiratory stability was assessed and compared. The Neonatal Pain Agitation and Sedation Scale (N-PASS) was used to evaluate tolerability in infants that underwent intravenous fentanyl sedation. 97 cases of prematurity were included in this study. In 94/97 (96.9%) cases, vascular proliferation regressed. In the topical anaesthesia groups, the ophthalmologist needed 12-16 min more to complete the treatment. During the 3 postoperative days, topical anaesthesia demonstrated the greatest instability; 4/31 (12.90%) infants in this group suffered from life threatening events requiring resuscitation. The only instability observed in general anaesthesia and fentanyl sedation was attributed to difficulty in extubating within 24 hours after surgery. During laser therapy, the N-PASS score increased to 1.8 in the fentanyl sedation group. Topical anaesthesia was associated with more cardiorespiratory instability during ROP laser treatment. While general anaesthesia and fentanyl sedation had similar postoperative cardiorespiratory results, the latter demonstrated acceptable pain stress control. However, the difficulty of weaning off mechanical ventilation in some cases after surgery needs to be addressed in future studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Radiobiological effectiveness of laser accelerated electrons in comparison to electron beams from a conventional linear accelerator.

    PubMed

    Laschinsky, Lydia; Baumann, Michael; Beyreuther, Elke; Enghardt, Wolfgang; Kaluza, Malte; Karsch, Leonhard; Lessmann, Elisabeth; Naumburger, Doreen; Nicolai, Maria; Richter, Christian; Sauerbrey, Roland; Schlenvoigt, Hans-Peter; Pawelke, Jörg

    2012-01-01

    The notable progress in laser particle acceleration technology promises potential medical application in cancer therapy through compact and cost effective laser devices that are suitable for already existing clinics. Previously, consequences on the radiobiological response by laser driven particle beams characterised by an ultra high peak dose rate have to be investigated. Therefore, tumour and non-malignant cells were irradiated with pulsed laser accelerated electrons at the JETI facility for the comparison with continuous electrons of a conventional therapy LINAC. Dose response curves were measured for the biological endpoints clonogenic survival and residual DNA double strand breaks. The overall results show no significant differences in radiobiological response for in vitro cell experiments between laser accelerated pulsed and clinical used electron beams. These first systematic in vitro cell response studies with precise dosimetry to laser driven electron beams represent a first step toward the long term aim of the application of laser accelerated particles in radiotherapy.

  8. Influence of turbulent atmosphere on laser beams from confocal unstable resonators

    NASA Astrophysics Data System (ADS)

    Peng, Yu-feng; Wang, Juan; Bi, Xiao-qun; Zhang, Ming-gao; Cheng, Zu-hai

    2009-07-01

    Based on the laser fields from a positive confocal unstable resonator (ab initio), the propagation characteristics of the beam through turbulent atmosphere are investigated by means of fast Fourier transform algorithm (FFT). To conveniently investigate the propagation characteristics of laser beam through the atmosphere, as far as known, in the previous many works, a mathematical expression was generally artificially predefined to represent the given laser beam, such as Gaussian beam, Hermite-cosh-Gaussian beam, flat topped beam, dark-hollow (annular) beam, etc. In this paper, by basing on the initial built in oscillation of a laser resonator, such as a positive confocal unstable resonator (CUR), we studied the intensity distributions of the output laser field to obtain the propagation characteristics of laser beam through the turbulent atmosphere as functions of different propagation distances. The results show that the turbulence will result in the degradation of the peak value of the laser intensity in the far field, the spread of the far field diagram patterns, and the beam quality characteristics greatly degraded.

  9. A low-cost, tunable laser lock without laser frequency modulation

    NASA Astrophysics Data System (ADS)

    Shea, Margaret E.; Baker, Paul M.; Gauthier, Daniel J.

    2015-05-01

    Many experiments in optical physics require laser frequency stabilization. This can be achieved by locking to an atomic reference using saturated absorption spectroscopy. Often, the laser frequency is modulated and phase sensitive detection used. This method, while well-proven and robust, relies on expensive components, can introduce an undesirable frequency modulation into the laser, and is not easily frequency tuned. Here, we report a simple locking scheme similar to those implemented previously. We modulate the atomic resonances in a saturated absorption setup with an AC magnetic field created by a single solenoid. The same coil applies a DC field that allows tuning of the lock point. We use an auto-balanced detector to make our scheme more robust against laser power fluctuations and stray magnetic fields. The coil, its driver, and the detector are home-built with simple, cheap components. Our technique is low-cost, simple to setup, tunable, introduces no laser frequency modulation, and only requires one laser. We gratefully acknowledge the financial support of the NSF through Grant # PHY-1206040.

  10. Quasi-monoenergetic laser-plasma acceleration of electrons to 2 GeV

    PubMed Central

    Wang, Xiaoming; Zgadzaj, Rafal; Fazel, Neil; Li, Zhengyan; Yi, S. A.; Zhang, Xi; Henderson, Watson; Chang, Y.-Y.; Korzekwa, R.; Tsai, H.-E.; Pai, C.-H.; Quevedo, H.; Dyer, G.; Gaul, E.; Martinez, M.; Bernstein, A. C.; Borger, T.; Spinks, M.; Donovan, M.; Khudik, V.; Shvets, G.; Ditmire, T.; Downer, M. C.

    2013-01-01

    Laser-plasma accelerators of only a centimetre’s length have produced nearly monoenergetic electron bunches with energy as high as 1 GeV. Scaling these compact accelerators to multi-gigaelectronvolt energy would open the prospect of building X-ray free-electron lasers and linear colliders hundreds of times smaller than conventional facilities, but the 1 GeV barrier has so far proven insurmountable. Here, by applying new petawatt laser technology, we produce electron bunches with a spectrum prominently peaked at 2 GeV with only a few per cent energy spread and unprecedented sub-milliradian divergence. Petawatt pulses inject ambient plasma electrons into the laser-driven accelerator at much lower density than was previously possible, thereby overcoming the principal physical barriers to multi-gigaelectronvolt acceleration: dephasing between laser-driven wake and accelerating electrons and laser pulse erosion. Simulations indicate that with improvements in the laser-pulse focus quality, acceleration to nearly 10 GeV should be possible with the available pulse energy. PMID:23756359

  11. Laser generation of XeCl exciplex molecules in a longitudinal repetitively pulsed discharge in a Xe - CsCl mixture

    NASA Astrophysics Data System (ADS)

    Boichenko, A. M.; Klenovskii, M. S.

    2015-12-01

    By using the previously developed kinetic model, we have carried out simulations to study the possibility of laser generation of XeCl exciplex molecules in the working medium based on a mixture of Xe with CsCl vapours, excited by a longitudinal repetitively pulsed discharge. The formation mechanism of exciplex molecules in this mixture is fundamentally different from the formation mechanisms in the traditional mixtures of exciplex lasers. The conditions that make the laser generation possible are discussed. For these conditions, with allowance for available specific experimental conditions of the repetitively pulsed discharge excitation, we have obtained the calculated dependences of the power and efficiency of generation on the reflectivity of mirrors in a laser cavity.

  12. Laser plasma source for soft x-ray imaging in CIOM

    NASA Astrophysics Data System (ADS)

    Shao, Zhongxing; Wang, Zhanshan; Xu, Fengming; Lu, Junxia; Chen, Xingdan

    1997-10-01

    We previously reported 18 nm Schwartzchild microscope by using a laser plasma source. Now we are planning to improve our Nd:YAG laser system and the multilayers mirror of Mo/B4C instead of Mo/Si, for producing shorter wavelength radiation and developing a new soft x-ray imaging setup. To compress the pulse width of the laser, the SBS (Stimulated Brillouin Scattering) cells is available. To short the wavelength to the 4th harmonics of the laser with high as 0.4 J energy per pulse, the hindrance is the low, less than 20%, nonlinear conversion efficiency. In this paper we are going to briefly introduce the new method to overcome the hindrance and the configuration of the SBS cell.

  13. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Low-threshold generation of harmonics and hard x radiation in a laser plasma. 2. Multipeak generation

    NASA Astrophysics Data System (ADS)

    Apollonov, V. V.; Derzhavin, S. I.; Kazakov, K. Kh

    1993-02-01

    The conditions for the generation of hard x radiation with a multipeak structure in a plasma pumped by a long pulse from a free-running CO2 laser at a low intensity (q≲10 GW/cm2) have been studied. This x-ray generation had been observed in a previous study by the present authors. It is shown that this generation of hard x radiation with a multipeak structure leads to a more than tenfold increase in the yield of hard x radiation per laser pulse, under optimum conditions. This increase results from the additional peaks in the x-ray signal. An explanation of this effect is proposed.

  14. Non-stationary self-focusing of intense laser beam in plasma using ramp density profile

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habibi, M.; Ghamari, F.

    2011-10-15

    The non-stationary self-focusing of high intense laser beam in under-dense plasma with upward increasing density ramp is investigated. The obtained results show that slowly increasing plasma density ramp is very important in enhancing laser self-focusing. Also, the spot size oscillations of laser beam in front and rear of the pulse for two different density profiles are shown. We have selected density profiles that already were used by Sadighi-Bonabi et al.[Phys. Plasmas 16, 083105 (2009)]. Ramp density profile causes the laser beam to become more focused and penetrations deeps into the plasma by reduction of diffraction effects. Our computations show moremore » reliable results in comparison to the previous works.« less

  15. Continuous-wave supercontinuum laser based on an erbium-doped fiber ring cavity incorporating a highly nonlinear optical fiber.

    PubMed

    Lee, Ju Han; Takushima, Yuichi; Kikuchi, Kazuro

    2005-10-01

    We experimentally demonstrate a novel erbium-doped fiber based continuous-wave (cw) supercontinuum laser. The laser has a simple ring-cavity structure incorporating an erbium-doped fiber and a highly nonlinear dispersion-shifted fiber (HNL-DSF). Differently from previously demonstrated cw supercontinuum sources based on single propagation of a strong Raman pump laser beam through a highly nonlinear fiber, erbium gain inside the cavity generates a seed light oscillation, and the oscillated light subsequently evolves into a supercontinuum by nonlinear effects such as modulation instability and stimulated Raman scattering in the HNL-DSF. High quality of the depolarized supercontinuum laser output with a spectral bandwidth larger than 250 nm is readily achieved.

  16. Direct quantitative comparison of molecular responses in photodamaged human skin to fractionated and fully ablative carbon dioxide laser resurfacing.

    PubMed

    Orringer, Jeffrey S; Sachs, Dana L; Shao, Yuan; Hammerberg, Craig; Cui, Yilei; Voorhees, John J; Fisher, Gary J

    2012-10-01

    Fractionated ablative laser resurfacing has become a widely used treatment modality. Its clinical results are often found to approach those of traditional fully ablative laser resurfacing. To directly compare the molecular changes that result from fractionated and fully ablative carbon dioxide (CO(2)) laser resurfacing in photodamaged human skin. Photodamaged skin of 34 adult volunteers was focally treated at distinct sites with a fully ablative CO(2) laser and a fractionated CO(2) laser. Serial skin samples were obtained at baseline and several time points after treatment. Real-time reverse transcriptase polymerase chain reaction technology and immunohistochemistry were used to quantify molecular responses to each type of laser treatment. Fully ablative and fractionated CO(2) laser resurfacing induced significant dermal remodeling and collagen induction. After a single treatment, fractionated ablative laser resurfacing resulted in collagen induction that was approximately 40% to 50% as pronounced as that induced by fully ablative laser resurfacing. The fundamental cutaneous responses that result from fully ablative and fractionated carbon dioxide laser resurfacing are similar but differ in magnitude and duration, with the fully ablative procedure inducing relatively greater changes including more pronounced collagen induction. However, the molecular data reported here provide substantial support for fractionated ablative resurfacing as an effective treatment modality for improving skin texture. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  17. Single-frequency oscillation of thin-disk lasers due to phase-matched pumping.

    PubMed

    Vorholt, Christian; Wittrock, Ulrich

    2017-09-04

    We present a novel pump concept that should lead to single-frequency operation of thin-disk lasers without the need for etalons or other spectral filters. The single-frequency operation is due to matching the standing wave pattern of partially coherent pump light to the standing wave pattern of the laser light inside the disk. The output power and the optical efficiency of our novel pump concept are compared with conventional pumping. The feasibility of our pump concept was shown in previous experiments.

  18. New energy levels of atomic niobium (Nb I) discovered by laser-spectroscopic investigations

    NASA Astrophysics Data System (ADS)

    Kröger, S.; Windholz, L.; Başar, Gü.; Başar, Gö.

    2018-06-01

    We report the discovery of 9 previously unknown energy levels of the atomic niobium, all having even parity. Two levels have energies below 19,500 cm-1 and angular momentum J = 3/2, while the energies of the others are located between 39,700 and 43,420 cm-1. The levels were discovered by laser excitation of several unclassified spectral lines in the wavelength range between 554 nm and 650 nm and detection of laser-induced fluorescence with a monochromator.

  19. IDA Gamma-Ray Laser Annual Summary Report (1985). Investigation of the Feasibility of Developing a Laser Using Nuclear Transitions. Revised.

    DTIC Science & Technology

    1986-06-01

    beams of coherent radiation whose short wavelengths would permit greater penetration of matter than is possible with current laser sources. With that...nuclear linewidth. It is claimed that the time required for any narrowing is at least as long as the inverse of the linewidth achieved, no matter what...with the re- quired narrow line can be prepared is a different matter . The point is that the previous uncertainty principle does not forbid the

  20. Collisionless dissociation and isotopic enrichment of SF6 using high-powered CO2 laser radiation

    NASA Technical Reports Server (NTRS)

    Gower, M. C.; Billman, K. W.

    1977-01-01

    Dissociation of S-32F6 and the resultant isotopic enrichment of S-34F6 using high-powered CO2 laser radiation has been studied with higher experimental sensitivity than previously reported. Enrichment factors have been measured as a function of laser pulse number, wavelength, energy and time duration. A geometry independent dissociation cross section is introduced and measured values are presented. Threshold energy densities, below which no dissociation was observed, were also determined.

  1. Strong Optical Injection Locking of Edge-Emitting Lasers and Its Applications

    DTIC Science & Technology

    2006-08-18

    investigated for communications applications. Using AlGaAs lasers, Kobayashi et al. demonstrated stable single-mode operation of Fabry - Perot (F-P...modulation (AM) efficiency is obtained at the expense of linearity. Furthermore, the previous gain-lever devices were Fabry - Perot (F-P) lasers operating in...coating of ~ 0.2-μm Zirconium dioxide (ZrO2) layer with a reflectivity of less than 0.1% is deposited on one facet to suppress the Fabry - Perot (F-P

  2. Early treatment using fractional CO2 laser before skin suture during scar revision surgery in Asians.

    PubMed

    Du, Feiya; Yu, Yusheng; Zhou, Zhiqin; Wang, Liujia; Zheng, Shusen

    2018-04-01

    Fractional CO 2 laser is one of the most effective treatment options used to resurface scars. However, most previous studies have been performed on mature scars at least 2 months after surgery. Recent studies have emphasized the importance of early treatment to reduce scar formation. In the present study, we described our experience with fractional CO 2 laser intervention before skin suture during scar revision surgery in Asians, and found the treatment was safe and effective.

  3. Evidence for high-efficiency laser-heated hohlraum performance at 527 nm.

    PubMed

    Stevenson, R M; Oades, K; Thomas, B R; Schneider, M; Slark, G E; Suter, L J; Kauffman, R; Hinkel, D; Miller, M C

    2005-02-11

    A series of experiments conducted on the HELEN laser system [M. J. Norman, Appl. Opt.4120023497], into thermal x-ray generation from hohlraum targets using 527 nm (2omega) wavelength laser light, has shown that it is possible to exceed radiation temperatures previously thought limited by high levels of superthermal or hot electron production or stimulated backscatter. This Letter questions whether the assumptions traditionally applied to hohlraum design with respect to hot plasma filling and the use of 2omega light are too conservative.

  4. Direct carrier-envelope phase control of an amplified laser system.

    PubMed

    Balčiūnas, Tadas; Flöry, Tobias; Baltuška, Andrius; Stanislauskas, Tomas; Antipenkov, Roman; Varanavičius, Arūnas; Steinmeyer, Günter

    2014-03-15

    Direct carrier-envelope phase stabilization of an Yb:KGW MOPA laser system is demonstrated with a residual phase jitter reduced to below 100 mrad, which compares favorably with previous stabilization reports, both of amplified laser systems as well as of ytterbium-based oscillators. This novel stabilization scheme relies on a frequency synthesis scheme and a feed-forward approach. The direct stabilization of a sub-MHz frequency comb from a CPA amplifier not only reduces the phase noise but also greatly simplifies the stabilization setup.

  5. Refractive Index Seen by a Probe Beam Interacting with a Laser-Plasma System

    NASA Astrophysics Data System (ADS)

    Turnbull, D.; Goyon, C.; Kemp, G. E.; Pollock, B. B.; Mariscal, D.; Divol, L.; Ross, J. S.; Patankar, S.; Moody, J. D.; Michel, P.

    2017-01-01

    We report the first complete set of measurements of a laser-plasma optical system's refractive index, as seen by a second probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for crossed-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstration of a laser-plasma polarizer with 85 %- 87 % extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices.

  6. Refractive Index Seen by a Probe Beam Interacting with a Laser-Plasma System.

    PubMed

    Turnbull, D; Goyon, C; Kemp, G E; Pollock, B B; Mariscal, D; Divol, L; Ross, J S; Patankar, S; Moody, J D; Michel, P

    2017-01-06

    We report the first complete set of measurements of a laser-plasma optical system's refractive index, as seen by a second probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for crossed-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstration of a laser-plasma polarizer with 85%-87% extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices.

  7. Interaction of laser pulse with confined plasma during exit surface nanosecond laser damage

    NASA Astrophysics Data System (ADS)

    Rubenchik, Alexander M.; Feit, Michael D.; Demos, Stavros G.

    2013-12-01

    Interpretation of spatial and time resolved images of rear surface ns laser damage in dielectrics requires understanding of the dynamic interaction of the incoming laser beam with the confined expanding plasma in the material. The detailed kinetics of the plasma, involving both expansion and retraction, depends on details of reflection and absorption in the hot material. The growth of the hot region is treated using a model previously developed to understand laser peening. The pressure is found to scale as the square root of laser intensity and drops off slowly after energy deposition is complete. For the conditions of our experimental observations in fused silica, our model predicts a pressure of about 9 GPa and a surface expansion velocity of about 1.5 km/sec, in good agreement with experimental observation.

  8. Ultra-Intense Short-Pulse Pair Creation Using the Texas Petawatt Laser

    NASA Astrophysics Data System (ADS)

    Liang, Edison; Henderson, Alexander; Clarke, Taylor; Taylor, Devin; Chaguine, Petr; Serratto, Kristina; Riley, Nathan; Dyer, Gilliss; Donovan, Michael; Ditmire, Todd

    2013-10-01

    We report results from the 2012 pair creation experiment using the Texas Petawatt Laser. Up to 1011 positrons per steradian were detected using 100 Joule pulses from the Texas Petawatt Laser to irradiate gold targets, with peak laser intensities up to 1.9 × 1021W/cm2 and pulse durations as short as 130 fs. Positron-to-electron ratios exceeding 20% were measured on some shots. The positron energy, positron yield per unit laser energy, and inferred positron density are significantly higher than those reported in previous experiments. This confirms that, for a given laser energy, higher intensity and shorter pulses irradiating thicker targets are more favorable for pair creation. Narrow-band high-energy positrons up to 23 MeV were observed from thin targets. Supported by DOE Grant DE-SC-0001481 and Rice FIF.

  9. TEM00 mode Nd:YAG solar laser by side-pumping a grooved rod

    NASA Astrophysics Data System (ADS)

    Vistas, Cláudia R.; Liang, Dawei; Almeida, Joana; Guillot, Emmanuel

    2016-05-01

    A simple TEM00 mode solar laser system with a grooved Nd:YAG rod pumped through a heliostat-parabolic mirror system is reported here. The radiation coupling capacity of a fused silica tube lens was combined with the multipass pumping ability of a 2 V-shaped cavity to provide efficient side-pumping along a 4.0 mm diameter grooved Nd:YAG single-crystal rod. TEM00 mode solar laser power of 3.4 W was measured by adopting an asymmetric large-mode laser resonant cavity. Record TEM00 mode solar laser collection efficiency of 3.4 W/m2and slope efficiency of 1.9% was achieved, which corresponds to 1.8 and 2.4 times more than the previous TEM00 mode Nd:YAG solar laser using the PROMES-CNRS heliostat-parabolic mirror system, respectively.

  10. Biological applications and effects of optical masers

    NASA Astrophysics Data System (ADS)

    Ham, William T., Jr.; Mueller, Harold A.; Williams, Ray C.; Geeraets, Walter J.; Ruffolo, John J., Jr.

    1988-02-01

    Research experiments and projects pertaining to the ocular hazards of lasers and other optical sources are reviewed and discussed in some detail. Early studies to determine threshold retinal damage in the rabbit from ruby and neodymium lasers are described and followed by more elaborate experiments with monkeys using the He;Ne laser. A comparison between threshold retinal lesions in human volunteers, monkeys and rabbits is given. Retinal damage in the rhesus monkey is evaluated in terms of visual acuity. Quantitative data on solar retinitis as determined in the rhesus monkey are provided and the effects of wavelength on light toxicity are evaluated for eight monochromatic laser lines. Experiments performed at Los Alamos to evaluate the ocular effects and hazards of picosecond and nanosecond pulses of radiation from CO2 and HF lasers are described. A list of published papers describing the above research is included. The HF laser effects on the rabbit cornea were very similar to those caused by exposure to the CO2 laser. The energy from the CO2 and HF lasers is completely absorbed in the superficial layers of the cornea, creating a sharp sonic or shock wave which can disrupt the epithelial cells but does not penetrate to the stroma.

  11. Laser in the management of burn scars.

    PubMed

    Willows, Brooke M; Ilyas, Muneeb; Sharma, Amit

    2017-11-01

    Burn scars are associated with significant morbidity ranging from contractures, pruritus, and disfigurement to psychosocial impairment. Traditional therapies include silicone gel, compression garments, corticosteroid injections, massage therapy, and surgical procedures, however, newer and advanced therapies for the treatment of burn scars have been developed. Lasers, specifically ablative fractional lasers, show potential for the treatment of burn scars. Both MeSH and keyword searches of the PubMed, Medline and Embase databases were performed and relevant articles were read in full for the compilation of this review. Fifty-one relevant observational studies, clinical trials, and systematic reviews published in English from 2006 to 2016 were reviewed and summarized. Laser therapy is effective for the treatment of burn scar appearance, including measures such as pigmentation, vascularity, pliability, and thickness. Ablative fractional laser therapy, in particular, shows significant potential for the release of contractures allowing for improved range of motion of affected joints. Patients may benefit from the use of lasers in the treatment of burn scars, and the safety profile of lasers allows the benefits of treatment to outweigh the risks. Laser therapy should be included in burn scar treatment protocols as an adjuvant therapy to traditional interventions. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  12. Octave spanning supercontinuum in an As₂S₃ taper using ultralow pump pulse energy.

    PubMed

    Hudson, Darren D; Dekker, Stephen A; Mägi, Eric C; Judge, Alexander C; Jackson, Stuart D; Li, Enbang; Sanghera, J S; Shaw, L B; Aggarwal, I D; Eggleton, Benjamin J

    2011-04-01

    An octave spanning spectrum is generated in an As₂S₃ taper via 77 pJ pulses from an ultrafast fiber laser. Using a previously developed tapering method, we construct a 1.3 μm taper that has a zero-dispersion wavelength around 1.4 μm. The low two-photon absorption of sulfide-based chalcogenide fiber allows for higher input powers than previous efforts in selenium-based chalcogenide tapered fibers. This higher power handling capability combined with input pulse chirp compensation allows an octave spanning spectrum to be generated directly from the taper using the unamplified laser output.

  13. A re-evaluation of laser heterodyne radiometer ClO measurements. [for stratospheric chemistry studies

    NASA Technical Reports Server (NTRS)

    Menzies, R. T.

    1983-01-01

    Previously reported measurements of stratospheric ClO using a balloon-borne laser heterodyne radiometer, launched from Palestine, Texas, are re-evaluated as a result of recent spectroscopic data. A spectral feature which was observed during September, 1978 and November, 1979 flights was incorrectly identified as a ClO absorption line, while a second feature observed during the latter flight with somewhat limited sensitivity is now believed to be due to ClO. This new interpretation results in a measured ClO profile which falls off more rapidly with decreasing altitude than the previous results indicated.

  14. Fractional versus ablative erbium:yttrium-aluminum-garnet laser resurfacing for facial rejuvenation: an objective evaluation.

    PubMed

    El-Domyati, Moetaz; Abd-El-Raheem, Talal; Abdel-Wahab, Hossam; Medhat, Walid; Hosam, Wael; El-Fakahany, Hasan; Al Anwer, Mustafa

    2013-01-01

    Laser is one of the main tools for skin resurfacing. Erbium:yttrium-aluminum-garnet (Er:YAG) was the second ablative laser, after carbon dioxide, emitting wavelength of 2940 nm. Fractional laser resurfacing has been developed to overcome the drawbacks of ablative lasers. We aimed to objectively evaluate the histopathological and immunohistochemical effects of Er:YAG 2940-nm laser for facial rejuvenation (multiple sessions of fractional vs single session of ablative Er:YAG laser). Facial resurfacing with single-session ablative Er:YAG laser was performed on 6 volunteers. Another 6 were resurfaced using fractional Er:YAG laser (4 sessions). Histopathological (hematoxylin-eosin, orcein, Masson trichrome, and picrosirius red stains) and immunohistochemical assessment for skin biopsy specimens were done before laser resurfacing and after 1 and 6 months. Histometry for epidermal thickness and quantitative assessment for neocollagen formation; collagen I, III, and VII; elastin; and tropoelastin were done for all skin biopsy specimens. Both lasers resulted in increased epidermal thickness. Dermal collagen showed increased neocollagen formation with increased concentration of collagen types I, III, and VII. Dermal elastic tissue studies revealed decreased elastin whereas tropoelastin concentration increased after laser resurfacing. Neither laser showed significant difference between their effects clinically and on dermal collagen. Changes in epidermal thickness, elastin, and tropoelastin were significantly more marked after ablative laser. The small number of patients is a limitation, yet the results show significant improvement. Multiple sessions of fractional laser have comparable effects to a single session of ablative Er:YAG laser on dermal collagen but ablative laser has more effect on elastic tissue and epidermis. Copyright © 2012 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  15. Improvement of laser keyhole formation with the assistance of arc plasma in the hybrid welding process of magnesium alloy

    NASA Astrophysics Data System (ADS)

    Liu, Liming; Hao, Xinfeng

    2009-11-01

    In the previous work, low-power laser/arc hybrid welding technique is used to weld magnesium alloy and high-quality weld joints are obtained. In order to make clear the interactions between low-power laser pulse and arc plasma, the effect of arc plasma on laser pulse is studied in this article. The result shows that the penetration of low-power laser welding with the assistance of TIG arc is more than two times deeper than that of laser welding alone and laser welding transforms from thermal-conduction mode to keyhole mode. The plasma behaviors and spectra during the welding process are studied, and the transition mechanism of laser-welding mode is analyzed in detail. It is also found that with the assistance of arc plasma, the threshold value of average power density to form keyhole welding for YAG laser is only 3.3×10 4 W/cm 2, and the average peak power density is 2.6×10 5 W/cm 2 in the present experiment. Moreover, the distribution of energy density during laser pulse is modulated to improve the formation and stability of laser keyholes.

  16. Effect of the CO2 laser (9.6μm) on the dental pulp in humans

    NASA Astrophysics Data System (ADS)

    Wigdor, Harvey A.; Walsh, Joseph T., Jr.; Mostafi, Reza

    2000-03-01

    There has been great interest in the potential use of a laser to replace the dental handpiece (drill). Ideally a laser emitting radiation that is absorbed strongly by both the water and hydroxyapatite in teeth, would be a more efficient laser. Previous investigators showed that the 9.3 and 9.6 micron wavelength bands of the CO2 laser contain hydroxyapatite absorption peaks. For this study, human patients who were to have teeth removed for either orthodontic or periodontal reasons were used. A total of 16 teeth were irradiated. The number of teeth treated per patient varied from 1 - 4. The laser used was a prototype CO2 laser (ESC Medical Systems, Yokneam, Israel). The CO2 laser emits 50 mJ 60 microsecond-long pulses of 9.6 micrometer radiation in a beam focused to a 300 micrometer diameter (i/e2) spot. The pulps in both the laser and handpiece prepared holes appeared similar and had no apparent inflammation or vascular changes. It appears from this small sample of laser treated human teeth that this laser has an equal effect to the dental pulpal tissue when compared to the dental handpiece.

  17. Frequency-resolved optical gating with the use of second-harmonic generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeLong, K.W.; Trebino, R.; Hunter, J.

    1994-11-01

    We discuss the use of second-harmonic generation (SHG) as the nonlinearity in the technique of frequency-resolved optical gating (FROG) for measuring the full intensity and phase evolution of an arbitrary ultrashort pulse. FROG that uses a third-order nonlinearity in the polarization-gate geometry has proved extremely successful, and the algorithm required for extraction of the intensity and the phase from the experimental data is quite robust. However, for pulse intensities less than [similar to] 1 MW, third-order nonlinearities generate insufficient signal strength, and therefore SHG FROG appears necessary. We discuss the theoretical, algorithmic, and experimental considerations of SHG FROG in detail.more » SHG FROG has an ambiguity in the direction of time, and its traces are somewhat unintuitive. Also, previously published algorithms are generally ineffective at extracting the intensity and the phase of an arbitrary laser pulse from the SHG FROG trace. We present an improved pulse-retrieval algorithm, based on the method of generalized projections, that is far superior to the previously published algorithms, although it is still not so robust as the polarization-gate algorithm. We discuss experimental sources of error such as pump depletion and group-velocity mismatch. We also present several experimental examples of pulses measured with SHG FROG and show that the derived intensities and phases are in agreement with more conventional diagnostic techniques, and we demonstrate the high-dynamic-range capability of SHG FROG. We conclude that, despite the above drawbacks, SHG FROG should be useful in measuring low-energy pulses.« less

  18. Hydrodynamic study of plasma amplifiers for soft-x-ray lasers: a transition in hydrodynamic behavior for plasma columns with widths ranging from 20 μm to 2 mm.

    PubMed

    Oliva, Eduardo; Zeitoun, Philippe; Velarde, Pedro; Fajardo, Marta; Cassou, Kevin; Ros, David; Sebban, Stephan; Portillo, David; le Pape, Sebastien

    2010-11-01

    Plasma-based seeded soft-x-ray lasers have the potential to generate high energy and highly coherent short pulse beams. Due to their high density, plasmas created by the interaction of an intense laser with a solid target should store the highest amount of energy density among all plasma amplifiers. Our previous numerical work with a two-dimensional (2D) adaptive mesh refinement hydrodynamic code demonstrated that careful tailoring of plasma shapes leads to a dramatic enhancement of both soft-x-ray laser output energy and pumping efficiency. Benchmarking of our 2D hydrodynamic code in previous experiments demonstrated a high level of confidence, allowing us to perform a full study with the aim of the way for 10-100 μJ seeded soft-x-ray lasers. In this paper, we describe in detail the mechanisms that drive the hydrodynamics of plasma columns. We observed transitions between narrow plasmas, where very strong bidimensional flow prevents them from storing energy, to large plasmas that store a high amount of energy. Millimeter-sized plasmas are outstanding amplifiers, but they have the limitation of transverse lasing. In this paper, we provide a preliminary solution to this problem.

  19. Proton-transfer lasers based on solid copolymers of modified 2-(2'-hydroxyphenyl)benzimidazoles with methacrylate monomers

    NASA Astrophysics Data System (ADS)

    Costela, A.; García-Moreno, I.; Mallavia, Ricardo; Amat-Guerri, F.; Barroso, J.; Sastre, R.

    1998-06-01

    We report on the lasing action of two newly synthesized 2-(2'-hydroxyphenyl) benzimidazole derivatives copolymerized with methyl methacrylate. The laser samples were transversely pumped with a N 2 laser at 337 nm. The influence on the proton-transfer laser performance of the distance between the chromophore group and the polymeric main chain and of the rigidity of the polymeric host matrix, were studied. Significant increases in lasing efficiency and photostability are demonstrated for some of the new materials, as compared to those previously obtained with related proton-transfer dyes also covalently bound to methacrylic monomers.

  20. Robust sub-millihertz-level offset locking for transferring optical frequency accuracy and for atomic two-photon spectroscopy.

    PubMed

    Cheng, Wang-Yau; Chen, Ting-Ju; Lin, Chia-Wei; Chen, Bo-Wei; Yang, Ya-Po; Hsu, Hung Yi

    2017-02-06

    Robust sub-millihertz-level offset locking was achieved with a simple scheme, by which we were able to transfer the laser frequency stability and accuracy from either cesium-stabilized diode laser or comb laser to the other diode lasers who had serious frequency jitter previously. The offset lock developed in this paper played an important role in atomic two-photon spectroscopy with which record resolution and new determination on the hyperfine constants of cesium atom were achieved. A quantum-interference experiment was performed to show the improvement of light coherence as an extended design was implemented.

  1. Construction of a system for single-cell transgene induction in Caenorhabditis elegans using a pulsed infrared laser

    PubMed Central

    Churgin, Matthew A.; He, Liping; Murray, John I.; Fang-Yen, Christopher

    2014-01-01

    The spatial and temporal control of transgene expression is an important tool in C. elegans biology. We previously described a method for evoking gene expression in arbitrary cells by using a focused pulsed infrared laser to induce a heat shock response (Churgin et al 2013). Here we describe detailed methods for building and testing a system for performing single-cell heat shock. Steps include setting up the laser and associated components, coupling the laser beam to a microscope, and testing heat shock protocols. All steps can be carried out using readily available off-the-shelf components. PMID:24835576

  2. Calculation of the force acting on a micro-sized particle with optical vortex array laser beam tweezers

    NASA Astrophysics Data System (ADS)

    Kuo, Chun-Fu; Chu, Shu-Chun

    2013-03-01

    Optical vortices possess several special properties, including carrying optical angular momentum (OAM) and exhibiting zero intensity. Vortex array laser beams have attracts many interests due to its special mesh field distributions, which show great potential in the application of multiple optical traps and dark optical traps. Previously study developed an Ince-Gaussian Mode (IGM)-based vortex array laser beam1. This study develops a simulation model based on the discrete dipole approximation (DDA) method for calculating the resultant force acting on a micro-sized spherical dielectric particle that situated at the beam waist of the IGM-based vortex array laser beams1.

  3. Laser-induced ferroelectric domain engineering in LiNbO3 crystals using an amorphous silicon overlayer

    NASA Astrophysics Data System (ADS)

    Zisis, G.; Martinez-Jimenez, G.; Franz, Y.; Healy, N.; Masaud, T. M.; Chong, H. M. H.; Soergel, E.; Peacock, A. C.; Mailis, S.

    2017-08-01

    We report laser-induced poling inhibition and direct poling in lithium niobate crystals (LiNbO3), covered with an amorphous silicon (a-Si) light-absorbing layer, using a visible (488 nm) continuous wave laser source. Our results show that the use of the a-Si overlayer produces deeper poling inhibited domains with minimum surface damage, as compared to previously reported UV laser writing experiments on uncoated crystals, thus increasing the applicability of this method in the production of ferroelectric domain engineered structures for nonlinear optical applications. The characteristics of the poling inhibited domains were investigated using differential etching and piezoresponse force microscopy.

  4. Improving the particle beam characteristics resulting from laser ion acceleration at ultra high intensity through target manipulation - Numerical modeling

    NASA Astrophysics Data System (ADS)

    Tatomirescu, Dragos; d'Humieres, Emmanuel; Vizman, Daniel

    2017-12-01

    The necessity to produce superior quality ion and electron beams has been a hot research field due to the advances in laser science in the past decade. This work focuses on the parametric study of different target density profiles in order to determine their effect on the spatial distribution of the accelerated particle beam, the particle maximum energy, and the electromagnetic field characteristics. For the scope of this study, the laser pulse parameters were kept constant, while varying the target parameters. The study continues the work published in [1] and focuses on further studying the effects of target curvature coupled with a cone laser focusing structure. The results show increased particle beam focusing and a significant enhancement in particle maximum energy.

  5. Laser ablative nanostructuring of Au in liquid ambience in continuous wave illumination regime

    NASA Astrophysics Data System (ADS)

    Kucherik, A. O.; Kutrovskaya, S. V.; Arakelyan, S. M.; Ryabchikov, Y. V.; Al-Kattan, A.; Kabashin, A. V.; Itina, T. E.

    2016-03-01

    Gold nanoparticles (Au NPs) attract particular attention because of their unique size-dependent chemical, physicochemical and optical properties and, hence, their potential applications in catalysis, nanoelectronics, photovoltaics and medicine. In particular, laser-produced colloidal nanoparticles are not only biocompatible, but also reveal unique chemical properties. Different laser systems can be used for synthesis of these colloids, varying from continuous wave (CW) to ultra-short femtosecond lasers. The choice of an optimum laser system is still a challenge in application development. To bring more light at this issue, we investigate an influence of laser parameters on nanoparticle formation from a gold target immersed in deionized water. First, an optical diagnostics of laser-induced hydrodynamic processes taking place near the gold surface is performed. Then, gold nanoparticle colloids with average particle sizes smaller than 10 nm and a very narrow dispersion are shown to be formed by CW laser ablation. The obtained results are compared with the ones obtained by using the second harmonics and with previous results obtained by using femtosecond laser systems.

  6. Further characterization of photothermal breakdown products of uric acid stones following holmium:YAG laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Glickman, Randolph D.; Weintraub, Susan T.; Kumar, Neeru; Corbin, Nicole S.; Lesani, Omid; Teichman, Joel M. H.

    2000-06-01

    Previously we found that Ho:YAG laser (2120 nm) lithotripsy of uric acid stones produced cyanide, a known thermal breakdown product of uric acid. We now report that alloxan, another thermal breakdown product, is also likely produced. Uric acid stones (approximately 98% pure) of human origin were placed in distilled water and subjected to one of the following experimental treatments: unexposed control, exposed to Ho:YAG laser, Nd:YAG laser, or mechanically crushed. Samples were then processed for HPLC analysis with UV detection. Peaks were identified by comparison to authentic standards. All samples contained uric acid, with retention time (RT) about 6 min. All of the laser-exposed samples contained a peak that eluted at 2.5 min, identical to the RT of authentic alloxan. Ho:YAG laser irradiation, however, produced a larger presumed alloxan peak than did the Nd:YAG laser. The peak at 2.5 min, as well as unidentified later-eluting peaks, were present in the laser-exposed, but not the unexposed or mechanically crushed, samples. These results confirm the thermal nature of lithotripsy performed with long-pulse IR lasers.

  7. Identifying new saturation mechanisms hindering the development of plasma-based laser amplifiers utilizing Stimulated Raman Backscattering

    NASA Astrophysics Data System (ADS)

    Turnbull, David Pearson

    Stimulated Raman Backscattering (SRBS) has the potential to supplement existing laser amplification technology in order to exceed the maximum intensity that is attainable with modern systems. It utilizes a three wave interaction in plasma in order to transfer the energy from a long, low intensity pumping pulse to a short, counterpropagating seed pulse that undergoes temporal compression as it is amplified and should ultimately be able to reach unfocused intensities up to a relativistic limit about five orders of magnitude larger than conventional systems. If proven viable, it could democratize research conducted with ultraintense laser systems as well as open up new realms of physics. Following theoretical suggestions and previous experimental conclusions, longer and more uniform preformed plasma channels were successfully created by focusing one of the plasma-forming beams to a line using an axicon lens. The beams amplified in those plasma channels were in fact more energetic than those previously reported in the published literature. However, results remained far afield of the theoretical predictions, which prompted an effort to reconcile the analytical work suggesting this scheme can be highly efficient with the experimental results demonstrating saturation. A Frequency-Resolved Optical Gating diagnostic was built in order to obtain greater insight into the amplified pulse shape and frequency distribution, data from which indicated that there was very often a frequency shift that seems to detune the interaction. Several mechanisms appear to be potentially viable sources of this shift. One possibility is that an ion acoustic wave induces wave collapse of the primary Langmuir wave mediating SRBS; this would also increase the damping rate and might even facilitate particle trapping. Additional evidence of this scenario later appeared in the time-integrated spectrometer data. Another possibility is that the amplified seed pulse triggers additional ionization of the plasma. Since both of these effects would require a very low initial electron temperature, a method for determining that value using only the gas density and electron density was developed, the results of which were consistent with the requisite conditions. The development of advanced laser technology is relevant to the pursuit of inertial fusion energy. The importance of fusion as a future option for electricity generation was investigated using integrated assessment modeling. The results suggest that fusion energy could be very valuable under imposed limits on carbon dioxide emissions, in particular if other carbon-neutral baseload technologies prove uncompetitive or are otherwise constrained by nonmarket impediments.

  8. Laser Science & Technology Program Annual Report - 2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, H-L

    2001-03-20

    The Laser Science and Technology (LS&T) Program Annual Report 2001 provides documentation of the achievements of the LLNL LS&T Program during the April 2001 to March 2002 period using three formats: (1) an Overview that is a narrative summary of important results for the year; (2) brief summaries of research and development activity highlights within the four Program elements: Advanced Lasers and Components (AL&C), Laser Optics and Materials (LO&M), Short Pulse Laser Applications and Technologies (SPLAT), and High-Energy Laser System and Tests (HELST); and (3) a compilation of selected articles and technical reports published in reputable scientific or technology journalsmore » in this period. All three elements (Annual Overview, Activity Highlights, and Technical Reports) are also on the Web: http://laser.llnl.gov/lasers/pubs/icfq.html. The underlying mission for the LS&T Program is to develop advanced lasers, optics, and materials technologies and applications to solve problems and create new capabilities of importance to the Laboratory and the nation. This mission statement has been our guide for defining work appropriate for our Program. A major new focus of LS&T beginning this past year has been the development of high peak power short-pulse capability for the National Ignition Facility (NIF). LS&T is committed to this activity.« less

  9. Variability of pulsed energy outputs from three dermatology lasers during multiple simulated treatments.

    PubMed

    Britton, Jason

    2018-01-20

    Dermatology laser treatments are undertaken at regional departments using lasers of different powers and wavelengths. In order to achieve good outcomes, there needs to be good consistency of laser output across different weeks as it is custom and practice to break down the treatments into individual fractions. Departments will also collect information from test patches to help decide on the most appropriate treatment parameters for individual patients. The objective of these experiments is to assess the variability of the energy outputs from a small number of lasers across multiple weeks at realistic parameters. The energy outputs from 3 lasers were measured at realistic treatment parameters using a thermopile detector across a period of 6 weeks. All lasers fired in single-pulse mode demonstrated good repeatability of energy output. In spite of one of the lasers being scheduled for a dye canister change in the next 2 weeks, there was good energy matching between the two devices with only a 4%-5% variation in measured energies. Based on the results presented, clinical outcomes should not be influenced by variability in the energy outputs of the dermatology lasers used as part of the treatment procedure. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. A Systematic Study on the Generation of Multimetallic Lanthanide Fullerene ions by Laser Ablation Mass Spectrometry.

    PubMed

    Wang, Yiyun; Ma, LiFu; Mu, Lei; Ren, Juan; Kong, Xianglei

    2018-06-01

    Laser ablation masss spectromety has been previously proved to be a powerful tool for studying endohedro metallofullerene (EMF) ions. Our previous study showed the possiblity of forming multi-metallofullerene ions containg more than six metal atoms for La, Y and Lu. Thus, it is important to conduct a systematic study on the generation of multi-metallofullerenes and their distribuitons for all lanthanide elements. Experiments were performed on a 7.0 T Fourier transform ion cyclotron resonance (FT ICR) mass spectrometer. Laser ablation mass spectra were obtained by laser irradiation on mixtures of graphene and MCl 3 on a stainless steel plate, applying a 355 nm Nd: YAG laser with a typical energy of 2.5 mJ/pulse. Reaction test experiments were performed by introducing O 2 into the FT ICR cell with a pulse valve. Multi-metallofullerene ions Ce2-4C2m+, Pr2-4C2m+, Gd2-4C2m+, Nd3C2m+, Dy2-3C2m+, Tb2-7C2m+, Ho2-6C2m+ were observed in the mass spectra. For metal Sm and Eu, no multi-metallofullerene ion was observed. No reaction with O 2 was observed in the reaction experiments, verifying that these species had endohedral structures. For the observed series of multi-metallofullerene ions, tri-metallofullerene ions dominated their mass spectra. The results were further compared with previously generated EMF ions for La, Er, Tm, Yb and Lu. Endohedral lanthanide metallofullerene ions were generated by laser ablation of graphene and the corresponding metal salts MCl 3 (M = Ce, Pr, Nd, Gd, Tb, Dy and Ho) and studied with a FT ICR mass spectrometer. Typically, multi-metallofullerene ions of TbnC2m+2≤n≤780≤2m≤176, Ho6C2m+2≤n≤674≤2m≤162 were observed. The results show that the formation of multi-EMF ions containing lanthanides that have +3 and +4 oxidation states is easier than those containing +2 oxidation states in the process of laser ablation. This article is protected by copyright. All rights reserved.

  11. Application of the holmium:YAG laser for prostatectomy.

    PubMed

    Kabalin, J N; Gilling, P J; Fraundorfer, M R

    1998-02-01

    The authors review the current knowledge regarding the application of the Holmium: YAG laser for prostatectomy. Conventional surgical therapies for benign prostatic hyperplasia (BPH) are effective but associated with relatively high morbidity. Laser prostatectomy, using either Neodymium:YAG or potassium-titanyl-phosphate lasers, has emerged as a new and much safer operative approach to relieve symptoms of benign prostatic hyperplasia. However, these laser wavelengths possess key disadvantages that have limited their acceptability and dissemination in everyday urologic practice. THE authors review their own extensive experience in the development of clinical application of Holmium: YAG laser technology for prostatectomy, as well as the published reports in the current medical literature now dealing with this subject. In multiple clinical trials, Holmium:YAG laser resection of the prostate has proven efficacious in relieving symptomatic BPH. Both objective urodynamic measures of voiding outcomes and symptomatic improvement have been shown to be equivalent to standard electrocautery resection of the prostate. At the same time, these studies have demonstrated the superior safety and hemostasis of Holmium:YAG laser prostatectomy compared to electrocautery resection, similar to prior laser prostatectomy procedure. Unlike prior forms of laser prostatectomy, Holmium:YAG laser resection of the prostate acutely removes all obstructing prostate tissue, so that the postoperative catheterization requirement is typically only overnight and improvement in voiding is immediate. Current operative techniques and the latest technological developments to facilitate Holmium:YAG laser prostatectomy are described. Holmium: YAG laser prostatectomy combines the best features of prior laser prostatectomy technologies, including minimal complications and morbidity, with the efficacy and immediacy of voiding outcomes associated with conventional electrocautery resection of the prostate.

  12. Er,CR:YSGG lasers induce fewer dysplastic-like epithelial artefacts than CO2 lasers: an in vivo experimental study on oral mucosa.

    PubMed

    González-Mosquera, A; Seoane, J; García-Caballero, L; López-Jornet, P; García-Caballero, T; Varela-Centelles, P

    2012-09-01

    Our aim was to assess wounds made by lasers (CO(2) and Er,Cr:YSGG) for their epithelial architectural changes and width of damage. We allocated 60 Sprague-Dawley(®) rats into groups: glossectomy by CO(2) laser at 3 different wattages (n=10 in each); glossectomy by Er,Cr:YSGG laser at two different emissions (n=10 in each), and a control group (n=10). Histological examination assessed both prevalence and site of thermal artefacts for each group. Both lasers (CO(2) and Er,Cr:YSGG) caused the same type of cytological artefacts. The 3W Er,Cr:YSGG laser produced the fewest cytological artefacts/specimen, and was significantly different from the other experimental groups: 3W CO(2) laser (95% CI=0.8 to 1.0); the 6W CO(2) laser (95% CI=0.1 to 2.0) and the 10W CO(2) laser (95% CI=1.1 to 3.0). CO(2) lasers (3-10W) generate epithelial damage that can simulate dysplastic changes with cytological atypia that affects mainly the basal and suprabasal layers. Irradiation with Er,CR:YSGG laser (2-4W) produces significantly fewer cellular artefacts and less epithelial damage, which may be potentially useful for biopsy of oral mucosa. Copyright © 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Mobile Robot Navigation and Obstacle Avoidance in Unstructured Outdoor Environments

    DTIC Science & Technology

    2017-12-01

    to pull information from the network, it subscribes to a specific topic and is able to receive the messages that are published to that topic. In order...total artificial potential field is characterized “as the sum of an attractive potential pulling the robot toward the goal…and a repulsive potential...of robot laser_max = 20; % robot laser view horizon goaldist = 0.5; % distance metric for reaching goal goali = 1

  14. A simple pendulum laser interferometer for determining the gravitational constant.

    PubMed

    Parks, Harold V; Faller, James E

    2014-10-13

    We present a detailed account of our 2004 experiment to measure the Newtonian constant of gravitation with a suspended laser interferometer. The apparatus consists of two simple pendulums hanging from a common support. Each pendulum has a length of 72 cm and their separation is 34 cm. A mirror is embedded in each pendulum bob, which then in combination form a Fabry-Perot cavity. A laser locked to the cavity measures the change in pendulum separation as the gravitational field is modulated due to the displacement of four 120 kg tungsten masses. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  15. X-Ray Laser Gets First Real-Time Snapshots of a Chemical Flipping a Biological Switch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-11-14

    Scientists have used the powerful X-ray laser at the Department of Energy’s SLAC National Accelerator Laboratory to make the first snapshots of a chemical interaction between two biomolecules – one that flips an RNA “switch” that regulates production of proteins, the workhorse molecules of life. The results, published in Nature, show the game-changing potential of X-ray free-electron lasers, or XFELs, for studying RNA, which guides protein manufacturing in the cell, serves as the primary genetic material in retroviruses such as HIV and also plays a role in most forms of cancer.

  16. Stable carbon isotope analyses of nanogram quantities of particulate organic carbon (pollen) with laser ablation nano combustion gas chromatography/isotope ratio mass spectrometry

    PubMed Central

    Sluijs, Appy; Laks, Jelmer J.; Reichart, Gert‐Jan

    2016-01-01

    Rationale Analyses of stable carbon isotope ratios (δ 13C values) of organic and inorganic matter remains have been instrumental for much of our understanding of present and past environmental and biological processes. Until recently, the analytical window of such analyses has been limited to samples containing at least several μg of carbon. Methods Here we present a setup combining laser ablation, nano combustion gas chromatography and isotope ratio mass spectrometry (LA/nC/GC/IRMS). A deep UV (193 nm) laser is used for optimal fragmentation of organic matter with minimum fractionation effects and an exceptionally small ablation chamber and combustion oven are used to reduce the minimum sample mass requirement compared with previous studies. Results Analyses of the international IAEA CH‐7 polyethylene standard show optimal accuracy, and precision better than 0.5‰, when measuring at least 42 ng C. Application to untreated modern Eucalyptus globulus (C3 plant) and Zea mays (C4 plant) pollen grains shows a ~ 16‰ offset between these species. Within each single Z. mays pollen grain, replicate analyses show almost identical δ 13C values. Conclusions Isotopic offsets between individual pollen grains exceed analytical uncertainties, therefore probably reflecting interspecimen variability of ~0.5–0.9‰. These promising results set the stage for investigating both δ 13C values and natural carbon isotopic variability between single specimens of a single population of all kinds of organic particles yielding tens of nanograms of carbon. © 2016 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd. PMID:27766694

  17. Real time laser speckle imaging monitoring vascular targeted photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Goldschmidt, Ruth; Vyacheslav, Kalchenko; Scherz, Avigdor

    2017-02-01

    Laser speckle imaging is a technique that has been developed to non-invasively monitor in vivo blood flow dynamics and vascular structure, at high spatial and temporal resolution. It can record the full-field spatio-temporal characteristics of microcirculation and has therefore, often been used to study the blood flow in tumors after photodynamic therapy (PDT). Yet, there is a paucity of reports on real-time laser speckle imaging (RTLSI) during PDT. Vascular-targeted photodynamic therapy (VTP) with WST11, a water-soluble bacteriochlorophyll derivative, achieves tumor ablation through rapid occlusion of the tumor vasculature followed by a cascade of events that actively kill the tumor cells. WST11-VTP has been already approved for treatment of early/intermediate prostate cancer at a certain drug dose, time and intensity of illumination. Application to other cancers may require different light dosage. However, incomplete vascular occlusion at lower light dose may result in cancer cell survival and tumor relapse while excessive light dose may lead to toxicity of nearby healthy tissues. Here we provide evidence for the feasibility of concomitant RTLSI of the blood flow dynamics in the tumor and surrounding normal tissues during and after WST11-VTP. Fast decrease in the blood flow is followed by partial mild reperfusion and a complete flow arrest within the tumor by the end of illumination. While the primary occlusion of the tumor feeding arteries and draining veins agrees with previous data published by our group, the late effects underscore the significance of light dose control to minimize normal tissue impairment. In conclusion- RTSLI application should allow to optimize VTP efficacy vs toxicity in both the preclinical and clinical arenas.

  18. Low level laser therapy (Photobiomodulation therapy) for breast cancer-related lymphedema: a systematic review.

    PubMed

    Baxter, G David; Liu, Lizhou; Petrich, Simone; Gisselman, Angela Spontelli; Chapple, Cathy; Anders, Juanita J; Tumilty, Steve

    2017-12-07

    Breast cancer related lymphedema (BCRL) is a prevalent complication secondary to cancer treatments which significantly impacts the physical and psychological health of breast cancer survivors. Previous research shows increasing use of low level laser therapy (LLLT), now commonly referred to as photobiomodulation (PBM) therapy, for BCRL. This systematic review evaluated the effectiveness of LLLT (PBM) in the management of BCRL. Clinical trials were searched in PubMed, AMED, Web of Science, and China National Knowledge Infrastructure up to November 2016. Two reviewers independently assessed the methodological quality and adequacy of LLLT (PBM) in these clinical trials. Primary outcome measures were limb circumference/volume, and secondary outcomes included pain intensity and range of motion. Because data were clinically heterogeneous, best evidence synthesis was performed. Eleven clinical trials were identified, of which seven randomized controlled trials (RCTs) were chosen for analysis. Overall, the methodological quality of included RCTs was high, whereas the reporting of treatment parameters was poor. Results indicated that there is strong evidence (three high quality trials) showing LLLT (PBM) was more effective than sham treatment for limb circumference/volume reduction at a short-term follow-up. There is moderate evidence (one high quality trial) indicating that LLLT (PBM) was more effective than sham laser for short-term pain relief, and limited evidence (one low quality trial) that LLLT (PBM) was more effective than no treatment for decreasing limb swelling at short-term follow-up. Based upon the current systematic review, LLLT (PBM) may be considered an effective treatment approach for women with BCRL. Due to the limited numbers of published trials available, there is a clear need for well-designed high-quality trials in this area. The optimal treatment parameters for clinical application have yet to be elucidated.

  19. Are Einstein's transition probabilities for spontaneous emission constant in plasmas?

    NASA Technical Reports Server (NTRS)

    Griem, H. R.; Huang, Y. W.; Wang, J.-S.; Moreno, J. C.

    1991-01-01

    An investigation is conducted with a ruby laser to experimentally confirm the quenching of spontaneous emission coefficients and propose a mechanism for the phenomenon. Results of previous experiments are examined to determine the consistency and validity of interpretations of the spontaneous emissions. For the C IV 3s-3p and 2s-3p transitions, the line-intensity ratios are found to be dependent on the separation of the laser from the target. Density gradients and Stark broadening are proposed to interpret the results in a way that does not invalidate the Einstein A values. The interpretation is extended to C III and N V, both of which demonstrate similar changes in A values in previous experiments. The apparent quenching of Ar II by photon collisions is explained by Rabi oscillations and power broadening in the argon-ion laser cavity. It is concluded that the changes in A values cannot result from dense plasma effects.

  20. Theoretical gain optimization studies in 10. 6. mu. m CO/sub 2/--N/sub 2/ gasdynamic lasers. IV. Further results of parametric study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, K.P.J.; Reddy, N.M.

    1984-01-01

    Based on a method proposed by Reddy and Shanmugasundaram, similar solutions have been obtained for the steady inviscid quasi-one-dimensional nonreacting flow in the supersonic nozzle of CO/sub 2/--N/sub 2/--H/sub 2/O and CO/sub 2/--N/sub 2/--He gasdynamic laser systems. Instead of using the correlations of a nonsimilar function N/sub S/ for pure N/sub 2/ gas, as is done in previous publications, the N/sub S/ correlations are computed here for the actual gas mixtures used in the gasdynamic lasers. Optimum small-signal optical gain and the corresponding optimum values of the operating parameters like reservoir pressure and temperature and nozzle area ratio are computedmore » using these correlations. The present results are compared with the previous results and the main differences are discussed.« less

  1. Ultrastable lasers based on vibration insensitive cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Millo, J.; Magalhaes, D. V.; Mandache, C.

    2009-05-15

    We present two ultrastable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultrastable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better than 1.5x10{sup -11}/m s{sup -2} for each spatial direction, which shows significant improvement over previous studies. We have tested the very low dependence on the position of the cavity support points, in order to establish that our designs eliminate the need for fine tuningmore » to achieve extremely low vibration sensitivity. Relative frequency measurements show that at least one of the stabilized lasers has a stability better than 5.6x10{sup -16} at 1 s, which is the best result obtained for this length of cavity.« less

  2. Growing Crystaline Sapphire Fibers By Laser Heated Pedestal Techiques

    DOEpatents

    Phomsakha, Vongvilay; Chang, Robert S. F.; Djeu, Nicholas I.

    1997-03-04

    An improved system and process for growing crystal fibers comprising a means for creating a laser beam having a substantially constant intensity profile through its cross sectional area, means for directing the laser beam at a portion of solid feed material located within a fiber growth chamber to form molten feed material, means to support a seed fiber above the molten feed material, means to translate the seed fiber towards and away from the molten feed material so that the seed fiber can make contact with the molten feed material, fuse to the molten feed material and then be withdrawn away from the molten feed material whereby the molten feed material is drawn off in the form of a crystal fiber. The means for creating a laser beam having a substantially constant intensity profile through its cross sectional area includes transforming a previously generated laser beam having a conventional gaussian intensity profile through its cross sectional area into a laser beam having a substantially constant intensity profile through its cross sectional area by passing the previously generated laser beam through a graded reflectivity mirror. The means for directing the laser beam at a portion of solid feed material is configured to direct the laser beam at a target zone which contains the molten feed material and a portion of crystal fiber drawn off the molten feed material by the seed fiber. The means to support the seed fiber above the molten feed material is positioned at a predetermined height above the molten feed material. This predetermined height provides the seed fiber with sufficient length and sufficient resiliency so that surface tension in the molten feed material can move the seed fiber to the center of the molten feed material irrespective of where the seed fiber makes contact with the molten feed material. The internal atmosphere of the fiber growth chamber is composed substantially of Helium gas.

  3. Local induction of calcium phosphate formation on TiO2 coatings on titanium via surface treatment with a CO2 laser.

    PubMed

    Moritz, N; Jokinen, M; Peltola, T; Areva, S; Yli-Urpo, A

    2003-04-01

    Sol-gel-derived TiO(2) coatings are known to promote bonelike hydroxyapatite formation on their surfaces in vitro and in vivo. Hydroxyapatite integrates into bone tissue. In some clinical applications, the surface of an implant is simultaneously interfaced with soft and hard tissues, so it should match the properties of both. A new method is introduced for treating the coatings locally in a controlled manner. The local densification of sol-gel-derived titania coatings on titanium substrates with a CO(2) laser was studied in terms of the in vitro calcium phosphate-inducting properties. CO(2)-laser-treated multilayer coatings were compared with furnace-fired coatings prepared with the same recipe and previously shown to be bioactive. Additionally, local areas of furnace-fired multilayer coatings (previously shown to be bioactive in vitro) were further laser-treated to achieve various properties in the same implant. Topological surface properties were examined with atomic force microscopy. The formation of hydroxyapatite was studied with Fourier transform infrared and scanning electron microscopy energy-dispersive X-ray analysis. The results show that calcium phosphate formation can be adjusted locally by laser treatment. Calcium phosphate is a bonelike hydroxyapatite. The local treatment of sol-gel-derived coatings with a CO(2) laser is a promising technique for creating implants with various properties to interface different tissues and a possible way of coating implants that do not tolerate furnace firing. Copyright 2003 Wiley Periodicals, Inc.

  4. High-resolution low-frequency fluctuation map of a multimode laser diode subject to filtered optical feedback via a fiber Bragg grating.

    PubMed

    Baladi, Fadwa; Lee, Min Won; Burie, Jean-René; Bettiati, Mauro A; Boudrioua, Azzedine; Fischer, Alexis P A

    2016-07-01

    A highly detailed and extended map of low-frequency fluctuations is established for a high-power multi-mode 980 nm laser diode subject to filtered optical feedback from a fiber Bragg grating. The low-frequency fluctuations limits and substructures exhibit substantial differences with previous works.

  5. Red-light-emitting laser diodes operating CW at room temperature

    NASA Technical Reports Server (NTRS)

    Kressel, H.; Hawrylo, F. Z.

    1976-01-01

    Heterojunction laser diodes of AlGaAs have been prepared with threshold current densities substantially below those previously achieved at room temperature in the 7200-8000-A spectral range. These devices operate continuously with simple oxide-isolated stripe contacts to 7400 A, which extends CW operation into the visible (red) portion of the spectrum.

  6. Intense Nanosecond-Pulsed Cavity-Dumped Laser Radiation at 1.04 THz

    NASA Astrophysics Data System (ADS)

    Wilson, Thomas

    2013-03-01

    We report first results of intense far-infrared (FIR) nanosecond-pulsed laser radiation at 1.04 THz from a previously described[2] cavity-dumped, optically-pumped molecular gas laser. The gain medium, methyl fluoride, is pumped by the 9R20 line of a TEA CO2 laser[3] with a pulse energy of 200 mJ. The THz laser pulses contain of 30 kW peak power in 5 nanosecond pulse widths at a pulse repetition rate of 10 Hz. The line width, measured by a scanning metal-mesh FIR Fabry-Perot interferometer, is 100 MHz. The novel THz laser is being used in experiments to resonantly excite coherent ns-pulsed 1.04 THz longitudinal acoustic phonons in silicon doping-superlattices. The research is supported by NASA EPSCoR NNX11AM04A and AFOSR FA9550-12-1-0100 awards.

  7. Modifying a Rodenstock scanning laser ophthalmoscope for imaging densitometry.

    PubMed

    Tornow, R P; Beuel, S; Zrenner, E

    1997-08-01

    The necessary modifications and technical requirements are described for using a commercially available scanning laser ophthalmoscope (Rodenstock Model 101 SLO) as an imaging densitometer to assess human photopigment distribution. The main requirements are a linear detector amplifier, fast shutters for the laser beams, and a trigger unit. Images must be compensated for varying laser intensity. Both rod and cone photopigments are measured with the 514-nm argon laser of the SLO. Discrimination is possible owing to the different spatial distribution. The cone pigment density peaks in the foveal center (D = 0.40) with a steep decrease with increasing eccentricity E (full width at half-maximum, 2.5 degrees ). Rod photopigment increases with increasing eccentricity (D = 0.23 for E = 11 degrees ). These values are in agreement with previous reported results obtained with scanning laser ophthalmoscopes specially designed for retinal densitometry and high stability.

  8. Multistage Coupling of Laser-Wakefield Accelerators with Curved Plasma Channels.

    PubMed

    Luo, J; Chen, M; Wu, W Y; Weng, S M; Sheng, Z M; Schroeder, C B; Jaroszynski, D A; Esarey, E; Leemans, W P; Mori, W B; Zhang, J

    2018-04-13

    Multistage coupling of laser-wakefield accelerators is essential to overcome laser energy depletion for high-energy applications such as TeV-level electron-positron colliders. Current staging schemes feed subsequent laser pulses into stages using plasma mirrors while controlling electron beam focusing with plasma lenses. Here a more compact and efficient scheme is proposed to realize the simultaneous coupling of the electron beam and the laser pulse into a second stage. A partly curved channel, integrating a straight acceleration stage with a curved transition segment, is used to guide a fresh laser pulse into a subsequent straight channel, while the electrons continue straight. This scheme benefits from a shorter coupling distance and continuous guiding of the electrons in plasma while suppressing transverse beam dispersion. Particle-in-cell simulations demonstrate that the electron beam from a previous stage can be efficiently injected into a subsequent stage for further acceleration while maintaining high capture efficiency, stability, and beam quality.

  9. Refractive Index Seen by a Probe Beam Interacting with a Laser-Plasma System

    DOE PAGES

    Turnbull, D.; Goyon, C.; Kemp, G. E.; ...

    2017-01-05

    Here, we report the first complete set of measurements of a laser-plasma optical system’s refractive index, as seen by a second probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for crossed-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstrationmore » of a laser-plasma polarizer with 85$-$87% extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices.« less

  10. Multistage Coupling of Laser-Wakefield Accelerators with Curved Plasma Channels

    NASA Astrophysics Data System (ADS)

    Luo, J.; Chen, M.; Wu, W. Y.; Weng, S. M.; Sheng, Z. M.; Schroeder, C. B.; Jaroszynski, D. A.; Esarey, E.; Leemans, W. P.; Mori, W. B.; Zhang, J.

    2018-04-01

    Multistage coupling of laser-wakefield accelerators is essential to overcome laser energy depletion for high-energy applications such as TeV-level electron-positron colliders. Current staging schemes feed subsequent laser pulses into stages using plasma mirrors while controlling electron beam focusing with plasma lenses. Here a more compact and efficient scheme is proposed to realize the simultaneous coupling of the electron beam and the laser pulse into a second stage. A partly curved channel, integrating a straight acceleration stage with a curved transition segment, is used to guide a fresh laser pulse into a subsequent straight channel, while the electrons continue straight. This scheme benefits from a shorter coupling distance and continuous guiding of the electrons in plasma while suppressing transverse beam dispersion. Particle-in-cell simulations demonstrate that the electron beam from a previous stage can be efficiently injected into a subsequent stage for further acceleration while maintaining high capture efficiency, stability, and beam quality.

  11. Carbon dioxide laser effects on caries-like lesions of dental enamel

    NASA Astrophysics Data System (ADS)

    Featherstone, John D. B.; Zhang, S. H.; Shariati, M.; McCormack, Sandra M.

    1991-05-01

    Previous studies by the authors have shown that carbon dioxide (CO2) laser light has marked effects on dental hard tissues and that these effects are wavelength-dependent. The aim of the present study was to determine whether treatment by CO2 laser of caries-like lesions in human enamel would inhibit subsequent lesion progression. Nine groups of 10 teeth each with preformed caries-like lesions were treated with/without CO2 laser (9.32 micrometers , 15 mJ or 25 mJ per pulse) by a pulsed laser (100-200 nsec) for either 200 or 400 pulses. Preformed lesions were then treated with acidulated phosphate fluoride for 5 minutes with control groups with no fluoride treatment. Teeth were subjected to a subsequent pH cycling challenge to determine the protection against lesion progression. Low energy laser treatment coupled with fluoride treatment entirely inhibited subsequent lesion progression in this model system.

  12. High efficiency laser-assisted H - charge exchange for microsecond duration beams

    DOE PAGES

    Cousineau, Sarah; Rakhman, Abdurahim; Kay, Martin; ...

    2017-12-26

    Laser-assisted stripping is a novel approach to H - charge exchange that overcomes long-standing limitations associated with the traditional, foil-based method of producing high-intensity, time-structured beams of protons. This paper reports on the first successful demonstration of the laser stripping technique for microsecond duration beams. The experiment represents a factor of 1000 increase in the stripped pulse duration compared with the previous proof-of-principle demonstration. The central theme of the experiment is the implementation of methods to reduce the required average laser power such that high efficiency stripping can be accomplished for microsecond duration beams using conventional laser technology. In conclusion,more » the experiment was performed on the Spallation Neutron Source 1 GeV H - beam using a 1 MW peak power UV laser and resulted in ~95% stripping efficiency.« less

  13. High efficiency laser-assisted H - charge exchange for microsecond duration beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cousineau, Sarah; Rakhman, Abdurahim; Kay, Martin

    Laser-assisted stripping is a novel approach to H - charge exchange that overcomes long-standing limitations associated with the traditional, foil-based method of producing high-intensity, time-structured beams of protons. This paper reports on the first successful demonstration of the laser stripping technique for microsecond duration beams. The experiment represents a factor of 1000 increase in the stripped pulse duration compared with the previous proof-of-principle demonstration. The central theme of the experiment is the implementation of methods to reduce the required average laser power such that high efficiency stripping can be accomplished for microsecond duration beams using conventional laser technology. In conclusion,more » the experiment was performed on the Spallation Neutron Source 1 GeV H - beam using a 1 MW peak power UV laser and resulted in ~95% stripping efficiency.« less

  14. Femtosecond-laser hyperdoping silicon in an SF{sub 6} atmosphere: Dopant incorporation mechanism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sher, Meng-Ju, E-mail: msher@stanford.edu; Mangan, Niall M.; Lin, Yu-Ting

    2015-03-28

    In this paper, we examine the fundamental processes that occur during femtosecond-laser hyperdoping of silicon with a gas-phase dopant precursor. We probe the dopant concentration profile as a function of the number of laser pulses and pressure of the dopant precursor (sulfur hexafluoride). In contrast to previous studies, we show the hyperdoped layer is single crystalline. From the dose dependence on pressure, we conclude that surface adsorbed molecules are the dominant source of the dopant atoms. Using numerical simulation, we estimate the change in flux with increasing number of laser pulses to fit the concentration profiles. We hypothesize that themore » native oxide plays an important role in setting the surface boundary condition. As a result of the removal of the native oxide by successive laser pulses, dopant incorporation is more efficient during the later stage of laser irradiation.« less

  15. Pump-probe imaging of nanosecond laser-induced bubbles in distilled water solutions: Observations of laser-produced-plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, R.; Camacho-Lopez, S.

    2010-11-15

    This article presents the analysis of the laser-produced-plasma (LPP) formed by the focusing of a 9 ns laser pulse, {lambda}=532 nm, with a NA=0.6 aspherical lens using energies between 100-1500 {mu}J, into distilled water with varying solutions of table salt. Observations of the filamentation plasma were made, which are explained by self-focusing of the laser pulse by the LPP through ponderomotive cavitation of the electron plasma in the center of the beam. The filamentation of the beam through a low density plasma wave guide explains why the transmission of the pump laser through the interaction region was notably higher onmore » previous experiments that we performed [R. Evans et al., Opt. Express 16, 7481 (2008)], than a very similar set of experiments performed by Noack and Vogel [IEEE J. Quantum Electron. 35, 1156 (1999)].« less

  16. Off-Axis and Angular Impulse Measurements on a Lightcraft Engine

    NASA Astrophysics Data System (ADS)

    Libeau, Michael; Myrabo, Leik

    2005-04-01

    A laser pulse into a Lightcraft engine applies three linear impulses and three angular impulses to the vehicle that depend on the engine's position and orientation with respect to the laser beam. The magnitudes on this impulsive reaction determine the vehicle's autonomous beam-riding characteristics. The impulsive reaction applied to the laser Lightcraft is examined and a device capable of measuring the reaction is designed and tested. Previous work has examined only the linear impulse acting in the thrust direction but the new apparatus, termed the Angular Impulse Measuring Device (AIMD), experimentally measures the dominant side impulse and dominant pitching angular impulse generated by the engine after a laser-strike. Recent tests of an 11/10 scale Model 200 Lightcraft were conducted using a 10KW Army laser at White Sands Missile Range. The resulting measurements are presented as a function of laser beam position.

  17. Caries inhibition with a CO2 9.3 μm laser: An in vitro study.

    PubMed

    Rechmann, Peter; Rechmann, Beate M T; Groves, William H; Le, Charles Q; Rapozo-Hilo, Marcia L; Kinsel, Richard; Featherstone, John D B

    2016-07-01

    The caries preventive effects of different laser wavelengths have been studied in the laboratory as well as in pilot clinical trials. The objective of this in vitro study was to evaluate whether irradiation with a new 9.3 μm microsecond short-pulsed CO2 -laser could enhance enamel caries resistance with and without additional fluoride applications. One hundred and one human tooth enamel samples were divided into seven groups. Each group was treated with different laser parameters (CO2 -laser, wavelength 9.3 μm, 43 Hz pulse-repetition rate, pulse duration between 3 µs at 1.5 mJ/pulse to 7 µs at 2.9 mJ/pulse). A laboratory pH-cycling model followed by cross-sectional microhardness testing determined the mean relative mineral loss delta Z (ΔZ) for each group to assess caries inhibition in tooth enamel by the CO2 9.3 µm short-pulsed laser irradiation. The pH-cycling was performed with or without additional fluoride. The non-laser control groups with additional fluoride had a relative mineral loss (ΔZ, vol% × µm) that ranged between 646 ± 215 and 773 ± 223 (mean ± SD). The laser irradiated and fluoride treated samples had a mean ΔZ ranging between 209 ± 133 and 403 ± 245 for an average 55% ± 9% reduction in mineral loss (ANOVA test, P < 0.0001). Increased mean mineral loss (ΔZ between 1166 ± 571 and 1339 ± 347) was found for the non-laser treated controls without additional fluoride. In contrast, the laser treated groups without additional fluoride showed a ΔZ between 470 ± 240 and 669 ± 209 (ANOVA test, P < 0.0001) representing an average 53% ± 11% reduction in mineral loss. Scanning electron microscopical assessment revealed that 3 µs pulses did not markedly change the enamel surface, while 7 µs pulses caused some enamel ablation. The CO2 9.3 µm short-pulsed laser energy renders enamel caries resistant with and without additional fluoride use. The observed enhanced acid resistance occurred with the laser irradiation parameters used without obvious melting of the enamel surface as well as after irradiation with energies causing cutting of the enamel. Lasers Surg. Med. 48:546-554, 2016. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  18. Investigation of Current Spike Phenomena During Heavy Ion Irradiation of NAND Flash Memories

    NASA Technical Reports Server (NTRS)

    Oldham, Timothy R.; Berg, Melanie; Friendlich, Mark; Wilcox, Ted; Seidleck, Christina; LaBel, Kenneth A.; Irom, Farokh; Buchner, Steven P.; McMorrow, Dale; Mavis, David G.; hide

    2011-01-01

    A series of heavy ion and laser irradiations were performed to investigate previously reported current spikes in flash memories. High current events were observed, however, none matches the previously reported spikes. Plausible mechanisms are discussed.

  19. Proposed SLR Optical Bench Required to Track Debris Using 1550 nm Lasers

    NASA Technical Reports Server (NTRS)

    Shappirio, M.; Coyle, D. B.; McGarry, J. F.; Bufton, J.; Cheek, J. W.; Clarke, G.; Hull, S. M.; Skillman, D. R.; Stysley, P. R.; Sun, X.; hide

    2015-01-01

    A previous study has indicated that by using approx.1550 nm wavelengths a laser ranging system can track debris objects in an "eye safe" manner, while increasing the expected return rate by a factor of approx. 2/unit area of the telescope. In this presentation we develop the optical bench required to use approx.1550nm lasers, and integration with a 532nm system. We will use the optical bench configuration for NGSLR as the baseline, and indicate a possible injection point for the 1550 nm laser. The presentation will include what elements may need to be changed for transmitting the required power on the approx.1550nm wavelength, supporting the alignment of the laser to the telescope, and possible concerns for the telescope optics.

  20. Active mode-locking of mid-infrared quantum cascade lasers with short gain recovery time.

    PubMed

    Wang, Yongrui; Belyanin, Alexey

    2015-02-23

    We investigate the dynamics of actively modulated mid-infrared quantum cascade lasers (QCLs) using space- and time-domain simulations of coupled density matrix and Maxwell equations with resonant tunneling current taken into account. We show that it is possible to achieve active mode locking and stable generation of picosecond pulses in high performance QCLs with a vertical laser transition and a short gain recovery time by bias modulation of a short section of a monolithic Fabry-Perot cavity. In fact, active mode locking in QCLs with a short gain recovery time turns out to be more robust to the variation of parameters as compared to previously studied lasers with a long gain recovery time. We investigate the effects of spatial hole burning and phase locking on the laser output.

  1. Delivery of molecules into cells using carbon nanoparticles activated by femtosecond laser pulses

    PubMed Central

    Chakravarty, Prerona; Qian, Wei; El-Sayed, Mostafa A.; Prausnitz, Mark R.

    2010-01-01

    A major barrier to drug and gene delivery is crossing the cell's plasma membrane. Physical forces applied to cells via electroporation1, ultrasound2 and laser-irradiation3–6 generate nanoscale holes in the plasma membrane for direct delivery of drugs into the cytoplasm. Inspired by previous work showing that laser excitation of carbon nanoparticles can drive the carbon-steam reaction to generate highly controlled shock waves7–10, here we show carbon black (CB) nanoparticles activated by femtosecond laser pulses can facilitate the delivery of small molecules, proteins and DNA into two types of cells. Our initial results suggest that interaction between the laser energy and CB nanoparticles may generate photoacoustic forces by chemical reaction to create transient holes in the membrane for delivery. PMID:20639882

  2. Characterization of quantum well laser diodes for application within the AMRDEC HWIL facilities

    NASA Astrophysics Data System (ADS)

    Saylor, Daniel A.; Bender, Matt; Cantey, Thomas M.; Beasley, D. B.; Buford, Jim A.

    2004-08-01

    The U.S. Army's Research, Development, and Engineering Command's (RDECOM) Aviation and Missile Research, Development, and Engineering Center (AMRDEC) provides Hardware-in-the-Loop (HWIL) test support to numerous tactical and theatre missile programs. Critical to the successful execution of these tests is the state-of-the-art technologies employed in the visible and infrared scene projector systems. This paper describes the results of characterizations tests performed on new mid-wave infrared (MWIR) quantum well laser diodes recently provided to AMRDEC by the Naval Research Labs and Sarnoff Industries. These lasers provide a +10X imrovement in MWIR output over the previous technology of lead-salt laser diodes. Performance data on output power, linearity, and solid-angle coverage are presented. A discussion of the laser packages is also provided.

  3. Monitoring the inhibition of erosion by a CO2 laser with OCT

    NASA Astrophysics Data System (ADS)

    Chan, Kenneth H.; Tom, Henry; Fried, Daniel

    2014-02-01

    Since optical coherence tomography (OCT) is well suited for measuring small dimensional changes on tooth surfaces, OCT has great potential for monitoring tooth erosion. Previous studies have shown that enamel areas ablated by a carbon dioxide laser manifested lower rates of erosion compared to the nonablated areas. The purpose of this study was to develop a model to monitor erosion in vitro that could potentially be used in vivo. Teeth surfaces were irradiated with a carbon dioxide laser at low sub-ablative fluence to create an acid-resistant reference layer without damaging the enamel. The laser treated areas were compared with the unprotected areas using OCT during exposure to a pH cycling model for up to 6 days. The laser treated areas markedly reduced the rate of erosion.

  4. Composite polymer: Glass edge cladding for laser disks

    DOEpatents

    Powell, H.T.; Wolfe, C.A.; Campbell, J.H.; Murray, J.E.; Riley, M.O.; Lyon, R.E.; Jessop, E.S.

    1987-11-02

    Large neodymium glass laser disks for disk amplifiers such as those used in the Nova laser require an edge cladding which absorbs at 1 micrometer. This cladding prevents edge reflections from causing parasitic oscillations which would otherwise deplete the gain. Nova now utilizes volume-absorbing monolithic-glass claddings which are fused at high temperature to the disks. These perform quite well but are expensive to produce. Absorbing glass strips are adhesively bonded to the edges of polygonal disks using a bonding agent whose index of refraction matches that of both the laser and absorbing glass. Optical finishing occurs after the strips are attached. Laser disks constructed with such claddings have shown identical gain performance to the previous Nova disks and have been tested for hundreds of shots without significant degradation. 18 figs.

  5. Composite polymer-glass edge cladding for laser disks

    DOEpatents

    Powell, Howard T.; Riley, Michael O.; Wolfe, Charles R.; Lyon, Richard E.; Campbell, John H.; Jessop, Edward S.; Murray, James E.

    1989-01-01

    Large neodymium glass laser disks for disk amplifiers such as those used in the Nova laser require an edge cladding which absorbs at 1 micrometer. This cladding prevents edge reflections from causing parasitic oscillations which would otherwise deplete the gain. Nova now utilizes volume-absorbing monolithic-glass claddings which are fused at high temperature to the disks. These perform quite well but are expensive to produce. Absorbing glass strips are adhesively bonded to the edges of polygonal disks using a bonding agent whose index of refraction matches that of both the laser and absorbing glass. Optical finishing occurs after the strips are attached. Laser disks constructed with such claddings have shown identical gain performance to the previous Nova disks and have been tested for hundreds of shots without significant degradation.

  6. Effects of malicious ocular laser exposure in commercial airline pilots.

    PubMed

    Palakkamanil, Mathew M; Fielden, Michael P

    2015-12-01

    Intentional malicious laser strikes on commercial pilots are committed by individuals who target a laser into airplane cockpits during takeoff and landing. Because laser exposure to pilots is a relatively new but growing occurrence, our study investigates the ocular effect of this laser exposure in pilots. Retrospective chart review by a single ophthalmologist. All commercial airline pilots (58 male, 3 female) who experienced a laser strike while flying between April 2012 and November 2014 who presented to our clinic were included. A retrospective chart review was performed in a retinal specialist's practice. Ocular assessment was performed within 3 days of laser exposure. A complete ophthalmic evaluation was conducted, including Early Treatment Diabetic Retinopathy Study visual acuity, colour vision, visual fields, intraocular pressure, slit-lamp examination, dilated fundus examination, colour fundus photographs, and ocular coherence tomography. Sixty-four laser strike incidents involving commercial pilots were included. All pilots in the study experienced some degree of immediate ocular irritation or light sensitivity. No definite cases of ocular damage were attributed to laser strikes. No pilot had any functional ocular deficits. Our study revealed that laser strikes on aircraft did not result in permanent visual functional or structural deficits. However, laser strikes cause immediate visual effects, including glare, flash blindness, and ocular irritation that can interfere with a pilot's visual function. Given the widespread accessibility of high-power lasers and the rapid increase in incidents, laser strikes threaten to jeopardize aviation safety unless effective preventative measures are put in place. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  7. On pulse duration of self-terminating lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bokhan, P A

    2011-02-28

    The problem of the maximum pulse duration {tau}{sub max} of self-terminating lasers is considered. It is shown that the duration depends on the transition probability in the laser channel, on the decay rate of the resonant state in all other channels, and on the excitation rate of the metastable state. As a result, {tau}{sub max} is found to be significantly shorter than previously estimated. The criteria for converting the 'self-terminating' lasing to quasi-cw lasing are determined. It is shown that in the case of nonselective depopulation of the metastable state, for example in capillary lasers or in a fast flowmore » of the active medium gas, it is impossible to obtain continuous lasing. Some concrete examples are considered. It is established that in several studies of barium vapour lasers ({lambda} = 1.5 {mu}m) and nitrogen lasers ({lambda} = 337 nm), collisional lasing is obtained by increasing the relaxation rate of the metastable state in collisions with working particles (barium atoms and nitrogen molecules). (lasers)« less

  8. Nd:YAG laser associated to different materials on seal of dentinal tubuli for dowel and post preparation

    NASA Astrophysics Data System (ADS)

    Aun, Carlos E.; de Campos Ferraz, Jussara; Silva Kfouri, Luciana

    1998-04-01

    Previous researches have discussed the importance of sealing the internal surface of the root canal after preparing it for posts or dowels, avoiding tubuli contamination by the oral environment. The purpose of this study was to investigate the effects of Neodymium-Yttrium-Aluminum-Garnet laser irradiation, associated or not with another materials, on the root inner walls after post space preparation. Forty single rooted endodontically treated teeth had theirs filings partially removed for prosthetics restoration, divided into 8 groups which received a coat of the following materials: group A: Copalite vanish; group B: Copalite vanish and laser; group C: Scothbond Multi-Purpose; group D: Scothbond Multi-Purpose and laser; group E: methylcianoacrilate; group F: methylcianocrilate and laser; group G: laser only; group H: control. The roots were placed in methylene blue dye and transversally cutted, then submitted to the analysis in the profile projector. So far we could observe that the Nd:Yag laser was able to enhance the sealing properties of the Scothbond Multi-Purpose.

  9. A novel high-resolution chaotic lidar with optical injection to chaotic laser diode

    NASA Astrophysics Data System (ADS)

    Wang, Yun-cai; Wang, An-bang

    2008-03-01

    A novel chaotic lidar with high resolution is proposed and studied theoretically. In chaotic lidar system, the chaotic laser emitted from chaotic laser diode is split into two beams: the probe and the reference light. The ranging is achieved by correlating the reference waveform with the delayed probe waveform backscattered from the target. In chaotic lidar systems presented previously, the chaotic signal source is laser diode with optical feedback or with optical injection by another one. The ranging resolution is limited by the bandwidth of chaotic laser which determined by the configuration of chaotic signal source. We proposed a novel chaotic lidar which ranging resolution is enhanced significantly by external optical injected chaotic laser diode. With the bandwidth-enhanced chaotic laser, the range resolution of the chaotic lidar system with optical injection is roughly two times compared with that of without optical injection. The resolution increases with injection strength increasing in a certain frequency detuning range.

  10. Surface-emitting circular DFB, disk- and ring- Bragg resonator lasers with chirped gratings: a unified theory and comparative study.

    PubMed

    Sun, Xiankai; Yariv, Amnon

    2008-06-09

    We have developed a theory that unifies the analysis of the modal properties of surface-emitting chirped circular grating lasers. This theory is based on solving the resonance conditions which involve two types of reflectivities of chirped circular gratings. This approach is shown to be in agreement with previous derivations which use the characteristic equations. Utilizing this unified analysis, we obtain the modal properties of circular DFB, disk-, and ring- Bragg resonator lasers. We also compare the threshold gain, single mode range, quality factor, emission efficiency, and modal area of these types of circular grating lasers. It is demonstrated that, under similar conditions, disk Bragg resonator lasers have the highest quality factor, the highest emission efficiency, and the smallest modal area, indicating their suitability in low-threshold, high-efficiency, ultracompact laser design, while ring Bragg resonator lasers have a large single mode range, high emission efficiency, and large modal area, indicating their suitability for high-efficiency, large-area, high-power applications.

  11. Transmutation prospect of long-lived nuclear waste induced by high-charge electron beam from laser plasma accelerator

    NASA Astrophysics Data System (ADS)

    Wang, X. L.; Xu, Z. Y.; Luo, W.; Lu, H. Y.; Zhu, Z. C.; Yan, X. Q.

    2017-09-01

    Photo-transmutation of long-lived nuclear waste induced by a high-charge relativistic electron beam (e-beam) from a laser plasma accelerator is demonstrated. A collimated relativistic e-beam with a high charge of approximately 100 nC is produced from high-intensity laser interaction with near-critical-density (NCD) plasma. Such e-beam impinges on a high-Z convertor and then radiates energetic bremsstrahlung photons with flux approaching 1011 per laser shot. Taking a long-lived radionuclide 126Sn as an example, the resulting transmutation reaction yield is the order of 109 per laser shot, which is two orders of magnitude higher than obtained from previous studies. It is found that at lower densities, a tightly focused laser irradiating relatively longer NCD plasmas can effectively enhance the transmutation efficiency. Furthermore, the photo-transmutation is generalized by considering mixed-nuclide waste samples, which suggests that the laser-accelerated high-charge e-beam could be an efficient tool to transmute long-lived nuclear waste.

  12. Study report on laser storage and retrieval of image data

    NASA Technical Reports Server (NTRS)

    Becker, C. H.

    1976-01-01

    The theoretical foundation is presented for a system of real-time nonphotographic and nonmagnetic digital laser storage and retrieval of image data. The system utilizes diffraction-limited laser focusing upon thin metal films, melting elementary holes in the metal films in laser focus. The metal films are encapsulated in rotating flexible mylar discs which act as the permanent storage carries. Equal sized holes encompass two dimensional digital ensembles of information bits which are time-sequentially (bit by bit) stored and retrieved. The bits possess the smallest possible size, defined by the Rayleigh criterion of coherent physical optics. Space and time invariant reflective read-out of laser discs with a small laser, provides access to the stored digital information. By eliminating photographic and magnetic data processing, which characterize the previous state of the art, photographic grain, diffusion, and gamma-distortion do not exist. Similarly, magnetic domain structures, magnetic gaps, and magnetic read-out are absent with a digital laser disc system.

  13. Alternative wavelengths for sutureless laser microvascular anastomosis: a preliminary study on acute samples.

    PubMed

    Bass, L S; Oz, M C; Libutti, S K; Treat, M R

    1992-06-01

    Attempts to improve the speed and patency of microvascular anastomosis with laser-assisted techniques have provided a modest reduction in operative time and comparable success rates. Using sutureless microvascular anastomoses, 30 end-to-end anastomoses were created in the rat carotid artery using the gallium-aluminum-arsenide diode laser (808 nm). Indocyanine green and fibrinogen were applied to enhance tissue absorption of the laser energy and strengthen the bond created. These were compared with previously reported welds using the THC:YAG laser (2150 nm). Mean welding times were 140 and 288 s, and mean bursting pressures immediately after welding were 515 and 400 mmHg for the diode and THC:YAG laser groups, respectively. Histologically, both lateral and vertical spread of thermal damage was limited. Since both lasers create welds of adequate initial strength without stay sutures and are faster and easier to use than existing systems, evaluation of long-term patency would be worthwhile.

  14. Multistage Coupling of Laser-Wakefield Accelerators with Curved Plasma Channel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, J.; Chen, M.; Wu, W. Y.

    Multistage coupling of laser-wakefield accelerators is essential to overcome laser energy depletion for high-energy applications such as TeV level electron-positron colliders. Current staging schemes feed subsequent laser pulses into stages using plasma mirrors, while controlling electron beam focusing with plasma lenses. Here a more compact and efficient scheme is proposed to realize simultaneous coupling of the electron beam and the laser pulse into a second stage. Furthermore, a curved channel with transition segment is used to guide a fresh laser pulse into a subsequent straight channel, while allowing the electrons to propagate in a straight channel. This scheme then benefitsmore » from a shorter coupling distance and continuous guiding of the electrons in plasma, while suppressing transverse beam dispersion. Within moderate laser parameters, particle-in-cell simulations demonstrate that the electron beam from a previous stage can be efficiently injected into a subsequent stage for further acceleration, while maintaining high capture efficiency, stability, and beam quality.« less

  15. Multistage Coupling of Laser-Wakefield Accelerators with Curved Plasma Channel

    DOE PAGES

    Luo, J.; Chen, M.; Wu, W. Y.; ...

    2018-04-10

    Multistage coupling of laser-wakefield accelerators is essential to overcome laser energy depletion for high-energy applications such as TeV level electron-positron colliders. Current staging schemes feed subsequent laser pulses into stages using plasma mirrors, while controlling electron beam focusing with plasma lenses. Here a more compact and efficient scheme is proposed to realize simultaneous coupling of the electron beam and the laser pulse into a second stage. Furthermore, a curved channel with transition segment is used to guide a fresh laser pulse into a subsequent straight channel, while allowing the electrons to propagate in a straight channel. This scheme then benefitsmore » from a shorter coupling distance and continuous guiding of the electrons in plasma, while suppressing transverse beam dispersion. Within moderate laser parameters, particle-in-cell simulations demonstrate that the electron beam from a previous stage can be efficiently injected into a subsequent stage for further acceleration, while maintaining high capture efficiency, stability, and beam quality.« less

  16. Contamination and UV lasers: lessons learned

    NASA Astrophysics Data System (ADS)

    Daly, John G.

    2015-09-01

    Laser induced damage to optical elements has been a subject of significant research, development, and improvement, since the first lasers were built over the last 50 years. Better materials, with less absorption, impurities, and defects are available, as well as surface coatings with higher laser damage resistance. However, the presence of contamination (particles, surface deposition films, or airborne) can reduce the threshold for damage by several orders of magnitude. A brief review of the anticipated laser energy levels for damage free operation is presented as a lead into the problems associated with contamination for ultraviolet (UV) laser systems. As UV lasers become more common in applications especially in areas such as lithography, these problems have limited reliability and added to costs. This has been characterized as Airborne Molecular Contamination (AMC) in many published reports. Normal engineering guidelines such as screening materials within the optical compartment for low outgassing levels is the first step. The use of the NASA outgassing database (or similar test methods) with low Total Mass Loss (TML) and Condensed Collected Volatiles Collected Mass (CVCM) is a good baseline. Energetic UV photons are capable of chemical bond scission and interaction with surface contaminant or airborne materials results in deposition of obscuring film laser footprints that continue to degrade laser system performance. Laser systems with average powers less than 5 mW have been shown to exhibit aggressive degradation. Lessons learned over the past 15 years with UV laser contamination and steps to reduce risk will be presented.

  17. Macrophage Infiltration Is a Causative Factor for Ligamentum Flavum Hypertrophy through the Activation of Collagen Production in Fibroblasts.

    PubMed

    Saito, Takeyuki; Hara, Masamitsu; Kumamaru, Hiromi; Kobayakawa, Kazu; Yokota, Kazuya; Kijima, Ken; Yoshizaki, Shingo; Harimaya, Katsumi; Matsumoto, Yoshihiro; Kawaguchi, Kenichi; Hayashida, Mitsumasa; Inagaki, Yutaka; Shiba, Keiichiro; Nakashima, Yasuharu; Okada, Seiji

    2017-12-01

    Ligamentum flavum (LF) hypertrophy causes lumbar spinal canal stenosis, leading to leg pain and disability in activities of daily living in elderly individuals. Although previous studies have been performed on LF hypertrophy, its pathomechanisms have not been fully elucidated. In this study, we demonstrated that infiltrating macrophages were a causative factor for LF hypertrophy. Induction of macrophages into the mouse LF by applying a microinjury resulted in LF hypertrophy along with collagen accumulation and fibroblasts proliferation at the injured site, which were very similar to the characteristics observed in the severely hypertrophied LF of human. However, we found that macrophage depletion by injecting clodronate-containing liposomes counteracted LF hypertrophy even with microinjury. For identification of fibroblasts in the LF, we used collagen type I α 2 linked to green fluorescent protein transgenic mice and selectively isolated green fluorescent protein-positive fibroblasts from the microinjured LF using laser microdissection. A quantitative RT-PCR on laser microdissection samples revealed that the gene expression of collagen markedly increased in the fibroblasts at the injured site with infiltrating macrophages compared with the uninjured location. These results suggested that macrophage infiltration was crucial for LF hypertrophy by stimulating collagen production in fibroblasts, providing better understanding of the pathophysiology of LF hypertrophy. Copyright © 2017 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  18. A simple method for rapid microbial identification from positive monomicrobial blood culture bottles through matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Lin, Jung-Fu; Ge, Mao-Cheng; Liu, Tsui-Ping; Chang, Shih-Cheng; Lu, Jang-Jih

    2017-06-30

    Rapid identification of microbes in the bloodstream is crucial in managing septicemia because of its high disease severity, and direct identification from positive blood culture bottles through matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) can shorten the turnaround time. Therefore, we developed a simple method for rapid microbiological identification from positive blood cultures by using MALDI-TOF MS. We modified previously developed methods to propose a faster, simpler and more economical method, which includes centrifugation and hemolysis. Specifically, our method comprises two-stage centrifugation with gravitational acceleration (g) at 600g and 3000g, followed by the addition of a lysis buffer and another 3000g centrifugation. In total, 324 monomicrobial bacterial cultures were identified. The success rate of species identification was 81.8%, which is comparable with other complex methods. The identification success rate was the highest for Gram-negative aerobes (85%), followed by Gram-positive aerobes (78.2%) and anaerobes (67%). The proposed method requires less than 10 min, costs less than US$0.2 per usage, and facilitates batch processing. We conclude that this method is feasible for clinical use in microbiology laboratories, and can serve as a reference for treatments or further complementary diagnostic testing. Copyright © 2017. Published by Elsevier B.V.

  19. Treatment outcome and prognostic factor of CO2 laser cordectomy for early glottic cancer

    NASA Astrophysics Data System (ADS)

    Chung, Phil-Sang; Lee, Sang Joon

    2012-02-01

    Objectives: Laser cordectomy is very popular nowadays and become one of the treatments of choice for early glottis carcinoma. Transoral laser microsurgery has many advantages comparing conventional open surgery or radiation therapy. In this study, we examined the oncologic results of laser cordectomy for early glottic cancer and analyzed the prognostic impact on the survival of the several tumor-related and treatment-related factors. Methods: Patients who were diagnosed as early glottic squamous cell carcinoma, treated by laser cordectomy with curative intent were analyzed. Patients with preivous radiation therapy were included. From June 1988 to March 2005, 202 patients from five hospitals were analyzed (174 T1, 28 T2). Results: Five-year overall survival and disease-free survival were 98.4% and 84.9%. Twenty two patients developed local recurrence. Total laryngectomy was done in 6 patients and laryngeal preservation rate was 97%. Recurrence was higher in the patients with anterior commissure involvement (9/39) than without anterior commissure involvement (13/163). Recurrence was higher in T1b (4/15) than T1a (13/159). Previous radiation was also highly related to the recurrence (7/20 vs 15/182). Twenty patients with local recurrence after radiation therapy were treated by salvage laser cordectomy. Of them, 7 patients developed local recurrence and 5 year disease-free survival was 57%. Complication was rare with one case of hemorrhage. Tracheotomy was not necessary in all patients. Conclusions: Laser cordectomy for early glottic carcinoma showed high survival, laryngeal preservation rate and low complication rate. The prognostic factors were anterior commissure involvement, both vocal fold involvement and previous radiotherapy.

  20. Studies of Optical Beam Phase-Conjugation and Electromagnetic Scattering Process

    DTIC Science & Technology

    1992-05-05

    34 S.M. Jensen and R.W. Hellwarth, Appl. Phys. Lett., 33 404, September, 1978. 3.3. " Infrared -to--optical image conversion by Bragg reflection from...paper WW2 at the 1988 Conference on Lasers and Electrooptics. 27 April 1988 at Anaheim, California. Abstract in Conference Bulletin. Summary published...in Technical Digest. Conference on Lasers and Electro-Optics (Optical Society of America, Washington, D.C., 1988). Paper WW2 . 16 4.74. "Fidelity of

  1. Theoretical studies of Resonance Enhanced Stimulated Raman Scattering (RESRS) of frequency doubled Alexandrite laser wavelength in cesium vapor

    NASA Technical Reports Server (NTRS)

    Lawandy, Nabil M.

    1987-01-01

    The third phase of research will focus on the propagation and energy extraction of the pump and SERS beams in a variety of configurations including oscillator structures. In order to address these questions a numerical code capable of allowing for saturation and full transverse beam evolution is required. The method proposed is based on a discretized propagation energy extraction model which uses a Kirchoff integral propagator coupled to the three level Raman model already developed. The model will have the resolution required by diffraction limits and will use the previous density matrix results in the adiabatic following limit. Owing to its large computational requirements, such a code must be implemented on a vector array processor. One code on the Cyber is being tested by using previously understood two-level laser models as guidelines for interpreting the results. Two tests were implemented: the evolution of modes in a passive resonator and the evolution of a stable state of the adiabatically eliminated laser equations. These results show mode shapes and diffraction losses for the first case and relaxation oscillations for the second one. Finally, in order to clarify the computing methodology used to exploit the speed of the Cyber's computational speed, the time it takes to perform both of the computations previously mentioned to run on the Cyber and VAX 730 must be measured. Also included is a short description of the current laser model (CAVITY.FOR) and a flow chart of the test computations.

  2. Micromirror-based real image laser automotive head-up display

    NASA Astrophysics Data System (ADS)

    Fan, Chao; He, Siyuan

    2017-01-01

    This paper reports a micromirror-based real image laser automotive head-up display (HUD), which overcomes the limitations of the previous designs by: (1) implementing an advanced display approach which is able to display sharp corners while the previous designs can only display curved lines such as to improve the display fidelity and (2) Optimizing the optical configuration to significantly reduce the HUD module size. The optical design in the HUD is simulated to choose the off-the-shelf concave lens. The vibration test is conducted to verify that the micromirror can survive 5 g. The prototype of the HUD system is fabricated and tested.

  3. Photoaggregation of crystallins (main proteins of eye lens) under the effect of XeCl laser radiation

    NASA Astrophysics Data System (ADS)

    Soustov, Lev V.; Chelnokov, Evgeny V.; Bityurin, Nikita M.; Kiselev, A. L.; Nemov, V. V.; Sergeev, Yu. V.; Ostrovsky, Michail A.

    2004-07-01

    UV light is one of primary factors associated with cataract formation in the eye lens. α-, β-, γ-Crystallins maintain lens transparency, and damage to these proteins plays a major role in cataract formation. The effect of XeCl laser radiation (308 nm) on βL-crystallin solution is studied. The strong dependence of protein aggregation kinetics on both laser fluence (w) and repetition rate (F) is investigated. The kinetics features are similar to those of carbonic anhydrase photoaggregation studied previously.

  4. Surface intervalley scattering on GaAs(110): Direct observation with picosecond laser photoemission

    NASA Astrophysics Data System (ADS)

    Haight, R.; Silberman, J. A.

    1989-02-01

    Angle-resolved laser photoemission investigations of the laser excited GaAs(110) surface have revealed a previously unobserved valley of the C3 unoccupied surface band whose minimum is at X¯ in the surface Brillouin zone. Electron population in this valley increases only as a result of scattering from the directly photoexcited valley at Γ¯. With high momentum resolution, we have isolated the dynamic electron population changes at both Γ¯ and X¯ and deduced the scattering time between the two valleys.

  5. Tunable diode laser measurements of HO2NO2 absorption coefficients near 12.5 microns

    NASA Technical Reports Server (NTRS)

    May, R. D.; Molina, L. T.; Webster, C. R.

    1988-01-01

    A tunable diode laser spectrometer has been used to measure absorption coefficients of peroxynitric acid (HO2NO2) near the 803/cm Q branch. HO2NO2 concentrations in a low-pressure flowing gas mixture were determined from chemical titration procedures and UV absorption spectroscopy. The diode laser measured absorption coefficients, at a spectral resolution of better than 0.001/cm, are about 10 percent larger than previous Fourier transform infrared measurements made at a spectral resolution of 0.06/cm.

  6. Single-pulse measurement of density and temperature in a turbulent, supersonic flow using UV laser spectroscopy

    NASA Technical Reports Server (NTRS)

    Fletcher, D. G.; Mckenzie, R. L.

    1992-01-01

    Nonintrusive measurements of density and temperature and their turbulent fluctuation levels have been obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment compare favorably with previous measurements obtained in the same facility from conventional probes and an earlier spectroscopic technique.

  7. Non-Ablative Fractional Laser to Facilitate Transdermal Delivery.

    PubMed

    Ganti, Sindhu S; Banga, Ajay K

    2016-11-01

    The advances in laser technology have led to its rapidly expanding applications in dermatology. This study aims at the novel use of a non-ablative fractional laser to enhance transdermal permeation of diclofenac sodium and sumatriptan succinate. The effects of the laser on skin were characterized visually with dye binding, scanning electron microscopy, pore permeability index, and histology. In vitro transdermal permeation of drugs through laser treated and untreated human dermatomed skin was analyzed over 24 h and quantified by HPLC. Drug transport through untreated skin resulted in transdermal delivery of 72.61 μg/cm 2 ± 50.35 and 22.80 ± 0.64 μg/cm 2 of diclofenac sodium and sumatriptan succinate, respectively. Laser treatment of skin significantly increased (p < 0.005) delivery of diclofenac sodium to 575.66 ± 207.18 μg/cm 2 and sumatriptan succinate to 498.32 ± 97.54 μg/cm 2 . This is a first of its kind study that demonstrates the use of 1410 nm non-ablative fractional laser to enhance transdermal permeation of 2 small molecular weight drugs. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  8. Laser-assisted drug delivery in dermatology: from animal models to clinical practice.

    PubMed

    Ali, Faisal R; Al-Niaimi, Firas

    2016-02-01

    Topical medicaments are the mainstay of the dermatologists' therapeutic arsenal. Laser-assisted drug delivery enhances the ability of topically applied medicaments to penetrate the skin. We discuss the mechanisms of laser-assisted drug delivery and animal models that have informed clinical practice. We review clinical studies that have employed laser-assisted drug delivery for a range of indications to date including non-melanoma skin cancer, vitiligo, scarring, vaccination, local anaesthesia, analgesia, viral warts, infantile haemangiomas and cosmetic uses. Studies thus far suggest that laser pre-treatment improves transepidermal absorption of topical agents and allows for a much deeper penetration of drugs than is possible with topical medicaments alone. This may allow more efficacious action of current treatments, such that conventional duration of treatment can be shortened or lower concentrations of active agents be used, potentially obviating side effects of treatment. The prospect of using laser technologies to facilitate transdermal vaccination and as an adjunct for inflammatory dermatoses and cosmetic indications remains in its infancy. As larger trials are published, involving greater numbers of patients and utilising various laser and topical medicament parameters, we will enhance our understanding of this nascent modality of treatment delivery.

  9. The use of ablative lasers in the treatment of facial melasma.

    PubMed

    Morais, Orlando Oliveira de; Lemos, Érica Freitas Lima; Sousa, Márcia Carolline dos Santos; Gomes, Ciro Martins; Costa, Izelda Maria Carvalho; Paula, Carmen Déa Ribeiro de

    2013-01-01

    Melasma represents a pigmentary disorder that is difficult to treat. This study aims to broadly review the use of ablative lasers (Er:YAG and CO2) in the treatment of melasma, presenting the level of evidence of studies published to date. A total of 75 patients were enrolled in four case series studies (n=39), one controlled clinical trial (n=6) and one randomized controlled clinical trial (n=30). Studies on the Er:YAG laser showed better results with the use of short square-shaped pulses, which determined low rates of post-inflammatory hyperpigmentation and long-lasting maintenance of results. Likewise, studies on the CO2 laser proved the benefits of short pulse duration along with low-density energy. Post-treatment maintenance with the use of antipigmenting creams was necessary and effective to sustain long-term results. Ablative lasers may represent another useful and effective tool against melasma. Postinflammatory hyperpigmentation and difficulty in sustaining long-term results still represent the main limitations to a broader use of ablative lasers. Based on actual evidence, the use of this technology should be restricted to patients with recalcitrant disease. Further studies will help establish optimal laser parameters and treatment regimens.

  10. The use of ablative lasers in the treatment of facial melasma*

    PubMed Central

    de Morais, Orlando Oliveira; Lemos, Érica Freitas Lima; Sousa, Márcia Carolline dos Santos; Gomes, Ciro Martins; Costa, Izelda Maria Carvalho; de Paula, Carmen Déa Ribeiro

    2013-01-01

    Melasma represents a pigmentary disorder that is difficult to treat. This study aims to broadly review the use of ablative lasers (Er:YAG and CO2) in the treatment of melasma, presenting the level of evidence of studies published to date. A total of 75 patients were enrolled in four case series studies (n=39), one controlled clinical trial (n=6) and one randomized controlled clinical trial (n=30). Studies on the Er:YAG laser showed better results with the use of short square-shaped pulses, which determined low rates of post-inflammatory hyperpigmentation and long-lasting maintenance of results. Likewise, studies on the CO2 laser proved the benefits of short pulse duration along with low-density energy. Post-treatment maintenance with the use of antipigmenting creams was necessary and effective to sustain long-term results. Ablative lasers may represent another useful and effective tool against melasma. Postinflammatory hyperpigmentation and difficulty in sustaining long-term results still represent the main limitations to a broader use of ablative lasers. Based on actual evidence, the use of this technology should be restricted to patients with recalcitrant disease. Further studies will help establish optimal laser parameters and treatment regimens. PMID:23739704

  11. Digital frequency offset-locked He–Ne laser system with high beat frequency stability, narrow optical linewidth and optical fibre output

    NASA Astrophysics Data System (ADS)

    Sternkopf, Christian; Manske, Eberhard

    2018-06-01

    We report on the enhancement of a previously-presented heterodyne laser source on the basis of two phase-locked loop (PLL) frequency coupled internal-mirror He–Ne lasers. Our new system consists of two digitally controlled He–Ne lasers with slightly different wavelengths, and offers high-frequency stability and very narrow optical linewidth. The digitally controlled system has been realized by using a FPGA controller and transconductance amplifiers. The light of both lasers was coupled into separate fibres for heterodyne interferometer applications. To enhance the laser performance we observed the sensitivity of both laser tubes to electromagnetic noise from various laser power supplies and frequency control systems. Furthermore, we describe how the linewidth of a frequency-controlled He–Ne laser can be reduced during precise frequency stabilisation. The digitally controlled laser source reaches a standard beat frequency deviation of less than 20 Hz (with 1 s gate time) and a spectral full width at half maximum (FWHM) of the beat signal less than 3 kHz. The laser source has enough optical output power to serve a fibre-coupled multi axis heterodyne interferometer. The system can be adjusted to output beat frequencies in the range of 0.1 MHz–20 MHz.

  12. Low-level laser effects on bacterial cultures submitted to heat stress

    NASA Astrophysics Data System (ADS)

    Gonçalves, E. M.; Guimarães, O. R.; Geller, M.; Paoli, F.; Fonseca, A. S.

    2016-06-01

    Low-level lasers have been used worldwide to treat a number of diseases, pain relief, and wound healing. Some studies demonstrated that low-level laser radiations induce effects depending on the physiological state and DNA repair mechanisms of cells. In this work we evaluated the effects of low-level red and infrared lasers on Escherichia coli cells deficient in SOS responses submitted to heat stress. Exponential and stationary E. coli cultures of wild type (AB1157), RecA deficient (AB2463) and LexA deficient (AB2494), both SOS response deficient, were exposed to low-level red and infrared lasers at different fluences and submitted to heat stress (42 °C, 20 min). After that, cell survival and morphology were evaluated. Previous exposure to red, but not infrared lasers, increases survival fractions and decreases the area ratios of E. coli AB1157 cells submitted to heat stress. Our research suggests that a low-level red laser increases cell viability and protects cells from morphological alteration in E. coli cultures submitted to heat stress depending on laser wavelength and SOS response.

  13. Leg ulcer plastic surgery descent by laser therapy

    NASA Astrophysics Data System (ADS)

    Telfer, Jacqui; Filonenko, Natalia; Salansky, Norman M.

    1994-02-01

    Low energy laser therapy (LELT) was used to treat chronic leg ulcers. Seven patients, aged 59 to 96 years, with 11 leg ulcers were referred for laser therapy by plastic surgeons. They had a history of ulceration of 3 - 50 years and five of the patients had breakdown of previous skin grafts. Laser treatments were administered with a microprocessor-controlled device. A 22 red ((lambda) equals 660 nm) laser head was utilized to provide a dose of (4 - 6) J/cm2 and 7 infrared ((lambda) equals 880 nm) head to provide a dose of (4 - 8) J/cm2. The patients were treated three to five times per week, 25 - 30 treatments per course. Three patients underwent two courses of laser therapy with three weeks interval between them. All patients, after 5 - 10 laser treatments, have gotten relief of pain and decreased the amount of analgesics used. All ulcers in six patients were completely healed and two ulcers in the seventh patient decreased in size by 75%. One may conclude the developed laser methodology might be used as a preventative measure to avoid plastic surgery or improve its success.

  14. Bichromatic random laser from a powder of rhodamine-doped sub-micrometer silica particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbosa-Silva, Renato; Silva, Andrea F.; Brito-Silva, Antonio M.

    2014-01-28

    We studied the random laser (RL) bichromatic emission (BCE) from a powder consisting of silica particles infiltrated with Rhodamine 640 (Rh640) molecules. The BCE is attributed to Rh640 monomers and dimers. Because of the efficient monomer-dimer energy transfer, we observed RL wavelength switching from ≈ 620 nm to ≈650 nm and the control of the emitted wavelength was made by changing only the excitation laser intensity. None of external parameters such as excitation laser spot size or radiation detector position was changed as in previous experiments. Two laser thresholds associated either to monomers or dimers were clearly observed. Moreover, an effect analogmore » to frequency-pulling among two coupled oscillators was identified measuring the RL spectra as a function of the excitation laser intensity. A wavelength shift, Δλ, was measured between the monomer and dimer resonance wavelengths, changing only the excitation laser intensity. The maximum value of Δλ ≈ 16 cm{sup −1} was obtained for laser pulses of 7 ns with 30 μJ.« less

  15. Measurement Issues In Pulsed Laser Propulsion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinko, John E.; Scharring, Stefan; Eckel, Hans-Albert

    Various measurement techniques have been used throughout the over 40-year history of laser propulsion. Often, these approaches suffered from inconsistencies in definitions of the key parameters that define the physics of laser ablation impulse generation. Such parameters include, but are not limited to the pulse energy, spot area, imparted impulse, and ablated mass. The limits and characteristics of common measurement techniques in each of these areas will be explored as they relate to laser propulsion. The idea of establishing some standardization system for laser propulsion data is introduced in this paper, so that reported results may be considered and studiedmore » by the general community with more certain understanding of particular merits and limitations. In particular, it is the intention to propose a minimum set of requirements a literature study should meet. Some international standards for measurements are already published, but modifications or revisions of such standards may be necessary for application to laser ablation propulsion. Issues relating to development of standards will be discussed, as well as some examples of specific experimental circumstances in which standardization would have prevented misinterpretation or misuse of past data.« less

  16. Evaluation of uranium transitions for isotopically-selective laser induced fluorescence with diode lasers (technical report for ST064)

    NASA Astrophysics Data System (ADS)

    Cannon, B. D.

    1993-10-01

    Isotopically-selective excitation of uranium atoms by diode lasers can be the basis for a portable instrument to perform uranium isotopic assays in the field. Such an instrument would improve the ability of on-site inspections to detect and deter nuclear proliferation. Published and unpublished spectroscopic data on atomic uranium were examined to identify candidate transitions for isotopically-selective laser excitation with diode lasers. Eleven candidate transitions were identified and evaluated for their potential usefulness for a portable uranium assay instrument. Eight of these transitions are suitable for laser induced fluorescence using different excitation and detection wavelengths, which will improve sensitivity and elemental selectivity. Data sheets on the 25 uranium transitions in the wavelength range 629 nm to 1,000 nm that originate in the ground or first excited states of neutral atomic uranium are included. Each data sheet provides the wavelength, upper and lower energy levels, angular momentum quantum numbers, U-235 isotope shift (relative to U-238, and high-resolution spectra of weapons-grade uranium (93% U-235 and 7% U-238).

  17. Types of Lasers and Their Applications in Pediatric Dentistry

    PubMed Central

    Nazemisalman, Bahareh; Farsadeghi, Mahya; Sokhansanj, Mehdi

    2015-01-01

    Laser technology has been recently introduced into the dental field with the idea to replace drilling. Having a less painful first dental experience by the use of modern instruments like laser can be an efficient preventive and therapeutic strategy in pediatric dentistry. Pedodontists need to learn the new less invasive technologies and adopt them in their routine practice. This study aimed to review the available types of lasers and their applications in pediatric dentistry. An electronic search was carried out in IranMedex, InterScience, Scopus, Science Direct, PubMed, ProQuest, Medline and Google Scholar databases to find relevant articles published from 2000 to 2014. Relevant textbooks were reviewed as well. Laser can be used as a suitable alternative to many conventional diagnostic and therapeutic dental procedures. It is especially efficient for caries detection and removal, pulp therapy, lowering the risk of infection, inflammation and swelling and reducing bleeding. On the other hand, due to minimal invasion, laser treatment is well tolerated by children. Improved patient cooperation leads to higher satisfaction of the parents, dentists and the children themselves. PMID:26464775

  18. Thermooptics of magnetoactive media: Faraday isolators for high average power lasers

    NASA Astrophysics Data System (ADS)

    Khazanov, E. A.

    2016-09-01

    The Faraday isolator, one of the key high-power laser elements, provides optical isolation between a master oscillator and a power amplifier or between a laser and its target, for example, a gravitational wave detector interferometer. However, the absorbed radiation inevitably heats the magnetoactive medium and leads to thermally induced polarization and phase distortions in the laser beam. This self-action process limits the use of Faraday isolators in high average power lasers. A unique property of magnetoactive medium thermooptics is that parasitic thermal effects arise on the background of circular birefringence rather than in an isotropic medium. Also, even insignificant polarization distortions of the radiation result in a worse isolation ratio, which is the key characteristic of the Faraday isolator. All possible laser beam distortions are analyzed for their deteriorating effect on the Faraday isolator parameters. The mechanisms responsible for and key physical parameters associated with different kinds of distortions are identified and discussed. Methods for compensating and suppressing parasitic thermal effects are described in detail, the published experimental data are systematized, and avenues for further research are discussed based on the results achieved.

  19. Analysis of laser therapy and assessment methods in the rehabilitation of temporomandibular disorder: a systematic review of the literature

    PubMed Central

    Herpich, Carolina Marciela; Amaral, Ana Paula; Leal-Junior, Ernesto Cesar Pinto; Tosato, Juliana de Paiva; Gomes, Cid Andre Fidelis de Paula; Arruda, Éric Edmur Camargo; Glória, Igor Phillip dos Santos; Garcia, Marilia Barbosa Santos; Barbosa, Bruno Roberto Borges; Rodrigues, Monique Sampaio; Silva, Katiane Lima; El Hage, Yasmin; Politti, Fabiano; Gonzalez, Tabajara de Oliveira; Bussadori, Sandra Kalil; Biasotto-Gonzalez, Daniela Aparecida

    2015-01-01

    The aim of the present study was to perform a systematic review of the literature on the effects of low-level laser therapy in the treatment of TMD, and to analyze the use of different assessment tools. [Subjects and Methods] Searches were carried out of the BIREME, MEDLINE, PubMed and SciELO electronic databases by two independent researchers for papers published in English and Portuguese using the terms: “temporomandibular joint laser therapy” and “TMJ laser treatment”. [Results] Following the application of the eligibility criteria, 11 papers were selected for in-depth analysis. The papers analyzed exhibited considerable methodological differences, especially with regard to the number of sessions, anatomic site and duration of low-level laser therapy irradiation, as well as irradiation parameters, diagnostic criteria and assessment tools. [Conclusion] Further studies are needed, especially randomized clinical trials, to establish the exact dose and ideal parameters for low-level laser therapy and define the best assessment tools in this promising field of research that may benefit individuals with signs and symptoms of TMD. PMID:25642095

  20. Beam uniformity of flat top lasers

    NASA Astrophysics Data System (ADS)

    Chang, Chao; Cramer, Larry; Danielson, Don; Norby, James

    2015-03-01

    Many beams that output from standard commercial lasers are multi-mode, with each mode having a different shape and width. They show an overall non-homogeneous energy distribution across the spot size. There may be satellite structures, halos and other deviations from beam uniformity. However, many scientific, industrial and medical applications require flat top spatial energy distribution, high uniformity in the plateau region, and complete absence of hot spots. Reliable standard methods for the evaluation of beam quality are of great importance. Standard methods are required for correct characterization of the laser for its intended application and for tight quality control in laser manufacturing. The International Organization for Standardization (ISO) has published standard procedures and definitions for this purpose. These procedures have not been widely adopted by commercial laser manufacturers. This is due to the fact that they are unreliable because an unrepresentative single-pixel value can seriously distort the result. We hereby propose a metric of beam uniformity, a way of beam profile visualization, procedures to automatically detect hot spots and beam structures, and application examples in our high energy laser production.

  1. Channel optimization of high-intensity laser beams in millimeter-scale plasmas.

    PubMed

    Ceurvorst, L; Savin, A; Ratan, N; Kasim, M F; Sadler, J; Norreys, P A; Habara, H; Tanaka, K A; Zhang, S; Wei, M S; Ivancic, S; Froula, D H; Theobald, W

    2018-04-01

    Channeling experiments were performed at the OMEGA EP facility using relativistic intensity (>10^{18}W/cm^{2}) kilojoule laser pulses through large density scale length (∼390-570 μm) laser-produced plasmas, demonstrating the effects of the pulse's focal location and intensity as well as the plasma's temperature on the resulting channel formation. The results show deeper channeling when focused into hot plasmas and at lower densities, as expected. However, contrary to previous large-scale particle-in-cell studies, the results also indicate deeper penetration by short (10 ps), intense pulses compared to their longer-duration equivalents. This new observation has many implications for future laser-plasma research in the relativistic regime.

  2. Picosecond laser welding of similar and dissimilar materials.

    PubMed

    Carter, Richard M; Chen, Jianyong; Shephard, Jonathan D; Thomson, Robert R; Hand, Duncan P

    2014-07-01

    We report picosecond laser welding of similar and dissimilar materials based on plasma formation induced by a tightly focused beam from a 1030 nm, 10 ps, 400 kHz laser system. Specifically, we demonstrate the welding of fused silica, borosilicate, and sapphire to a range of materials including borosilicate, fused silica, silicon, copper, aluminum, and stainless steel. Dissimilar material welding of glass to aluminum and stainless steel has not been previously reported. Analysis of the borosilicate-to-borosilicate weld strength compares well to those obtained using similar welding systems based on femtosecond lasers. There is, however, a strong requirement to prepare surfaces to a high (10-60 nm Ra) flatness to ensure a successful weld.

  3. Invited review article: Large ring lasers for rotation sensing.

    PubMed

    Schreiber, Karl Ulrich; Wells, Jon-Paul R

    2013-04-01

    Over the last two decades a series of large ring laser gyroscopes have been built having an unparalleled scale factor. These upscaled devices have improved the sensitivity and stability for rotation rate measurements by six orders of magnitude when compared to previous commercial developments. This progress has made possible entirely new applications of ring laser gyroscopes in the fields of geophysics, geodesy, and seismology. Ring lasers are currently the only viable measurement technology, which is directly referenced to the instantaneous rotation axis of the Earth. The sensor technology is rapidly developing. This is evidenced by the first experimentally viable proposals to make terrestrial tests of general relativistic effects such as the frame dragging of the rotating Earth.

  4. Unexpected impact of radiation friction: enhancing production of longitudinal plasma waves.

    PubMed

    Gelfer, Evgeny; Elkina, Nina; Fedotov, Alexander

    2018-04-24

    We study the penetration of ultra-intense (intensity I [Formula: see text] 10 23-24  W/cm 2 ) circularly polarized laser pulses into a thick subcritical plasma layer with accounting for radiation friction. We show that radiation pressure is enhanced due to radiation friction in the direction transverse to the laser pulse propagation, and that for stronger and longer laser pulses this mechanism dominates over the ordinary ponderomotive pressure, thus resulting in a substantionaly stronger charge separation than anticipated previously. We give estimates of the effect and compare them with the results of one and two dimensional particle-in-cell simulations. This effect can be important for laser-based acceleration schemes.

  5. Dependence of injection locking of a TEA CO2 laser on intensity of injected radiation

    NASA Technical Reports Server (NTRS)

    Oppenheim, U. P.; Menzies, R. T.; Kavaya, M. J.

    1982-01-01

    The results of an experimental study to determine the minimum required injected power to control the output frequency of a TEA CO2 laser are reported. A CW CO2 waveguide laser was used as the injection oscillator. Both the power and the frequency of the injected radiation were varied, while the TEA resonator cavity length was adjusted to match the frequency of the injected signal. Single-longitudinal mode (SLM) TEA laser radiation was produced for injected power levels which are several orders of magnitude below those previously reported. The ratio of SLM output power to injection power exceeded 10 to the 12th at the lowest levels of injected intensity.

  6. Highly efficient end-side-pumped Nd:YAG solar laser by a heliostat-parabolic mirror system.

    PubMed

    Almeida, J; Liang, D; Vistas, C R; Guillot, E

    2015-03-10

    We report a large improvement in the collection and slope efficiency of an Nd:YAG solar laser pumped by a heliostat-parabolic mirror system. A conical fused silica lens was used to further concentrate the solar radiation from the focal zone of a 2 m diameter primary concentrator to a Nd:YAG single-crystal rod within a conical pump cavity, which enabled multipass pumping to the active medium. A 56 W cw laser power was measured, corresponding to 21.1  W/m2 record-high solar laser collection efficiency with the heliostat-parabolic mirror system. 4.9% slope efficiency was calculated, corresponding to 175% enhancement over our previous result.

  7. Channel optimization of high-intensity laser beams in millimeter-scale plasmas

    NASA Astrophysics Data System (ADS)

    Ceurvorst, L.; Savin, A.; Ratan, N.; Kasim, M. F.; Sadler, J.; Norreys, P. A.; Habara, H.; Tanaka, K. A.; Zhang, S.; Wei, M. S.; Ivancic, S.; Froula, D. H.; Theobald, W.

    2018-04-01

    Channeling experiments were performed at the OMEGA EP facility using relativistic intensity (>1018W/cm 2 ) kilojoule laser pulses through large density scale length (˜390 -570 μ m ) laser-produced plasmas, demonstrating the effects of the pulse's focal location and intensity as well as the plasma's temperature on the resulting channel formation. The results show deeper channeling when focused into hot plasmas and at lower densities, as expected. However, contrary to previous large-scale particle-in-cell studies, the results also indicate deeper penetration by short (10 ps), intense pulses compared to their longer-duration equivalents. This new observation has many implications for future laser-plasma research in the relativistic regime.

  8. Recent advance to 3 × 10(-5) rad near diffraction-limited beam divergence of dye laser with transverse-discharge flash-lamp pumping.

    PubMed

    Trusov, K K

    1994-02-20

    A new experimental setup of a Rhodamine 6G dye laser with a transverse-discharge flash-lamp-pumping system is presented. It differs from a previous setup [Sov. J. Quantum Electron. 16, 468-471 (1989)] in that it has a larger laser beam aperture (32 mm) and higher pumping energy (1 kJ), which made it possible to test the scalability and reach near diffraction-limited laser beam divergence of 3 × 10(-5) rad FWHM at beam energy 1.4 J. The effect of spectral dispersion in the active medium and of other optical elements on the beam divergence is also discussed.

  9. Phase-matching properties of BaGa4Se7 for SHG and SFG in the 0.901-10.5910  μm range.

    PubMed

    Kato, Kiyoshi; Miyata, Kentaro; Petrov, Valentin

    2017-04-10

    We report new experimental results on the phase-matching properties of a BaGa4Se7 crystal for harmonic generation of a Nd:YAG laser-pumped AgGaS2 optical parametric oscillator (OPO) and a CO2 laser in the 0.901-10.5910 μm range. In addition, we present new Sellmeier equations that provide a good reproduction of the present experimental results as well as the published data points for a Nd:YAG laser-pumped OPO and an optical parametric amplifier (OPA) in the 3.10-15.22 μm range and a Ho:YAG laser-pumped OPA in the 3.49-5.18 μm range.

  10. Laser-assisted marking for toric intraocular lens alignment.

    PubMed

    Dick, H Burkhard; Schultz, Tim

    2016-01-01

    We describe a technique of 3-dimensional spectral-domain optical coherence tomography-controlled laser-assisted corneal marking for toric intraocular lens implantation. To facilitate accurate alignment, the technique creates 2 perpendicular intrastromal incisions (width 0.75 mm) using an image-guided femtosecond laser. This was performed in a case series comprising 10 eyes of 10 patients. No posterior corneal perforation or epithelial alterations occurred. The incisions were plainly visible under the operating microscope, and no optical phenomena were reported 6 weeks after surgery. Laser-assisted marking can be performed safely and has the potential to enable precise axis marking. Dr. Dick is a paid consultant to Abbott Medical Optics, Inc. Dr. Schultz has no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Peripheral laser assisted angioplasty: results, complications and follow-up.

    PubMed

    Owen, E R; Moussa, S A; Lewis, J D; Wilkins, R A

    1990-04-01

    Detailed results including complications and ultimate outcome of 24 laser assisted angioplasties in 22 patients are presented. Despite the enthusiasm expressed in other published reports, we remain sceptical of the value of laser using a 1.5 mm 'hot-tip' probe for assisting angioplasty of peripheral occlusions. The tendency for this type of probe to damage the vessel wall and in so doing prohibit the use of subsequent balloon dilatation is a major problem. In this small series the long-term patency was not improved compared with conventional angioplasty. We have established the relative safety of this laser technique and further advances in probe design may lead to greater success in crossing long lesions. Long-term maintenance of patency in these diseased arteries will need further advances in technique and assessment preferably by a controlled trial.

  12. Particle agglomerated 3-d nanostructures for photon absorption

    NASA Astrophysics Data System (ADS)

    Sivayoganathan, Mugunthan

    The main objective of this thesis is to investigate the photon absorption properties of particle agglomerated 3-D structures that are synthesized through femtosecond laser ablation of solids. The size and morphology of these particle agglomerated 3-D structures, which can be tailored through adjusting laser parameters, determine the photon absorption property. A systematic theoretical and experimental study was performed to identify the effect of lasers on the size of the formed particles. The literature survey showed that the amount of supersaturation influences the growth rate as well as the nucleation rate of vapour condensed nanoparticles. Based on this theory, a mechanism was formed to explain the control of laser parameters over the size of formed particles. Further, a theoretical explanation was proposed from the experimental results for the transition of particle size distribution modals. These proposed mechanisms and explanations show the variation in particle size in the particle agglomerated 3-D nanostructures with laser parameters. The effect of laser parameters on the formed ring size was studied. Based on the previous studies, a mechanism was proposed for the formation of ring nanoclusters. The laser pulse intensity dependent ponderomotive force was the key force to define the formation of ring nanoclusters. Then the effect of laser parameters on ring size was studied. Structures fabricated on several materials such as graphite, aluminosilicate ceramic, zinc ingot, gold, and titanium were analyzed to show the influence of material properties, laser parameters, and the environmental conditions on the size of ring formed. The studies performed on the structures showed a minimum absorption of 0.75 A.U. in the bandwidth from UV to IR. The absorption spectrum is much wider compared to existing nanomaterials, such as silicon nanostructures and titanium dioxide nanostructures. To the best of the author's knowledge, it is a very competitive absorption rate when compared with the previous nanostructures used in photovoltaic conversion. Several features of nanostructures contribute to the enhancement of this light absorption. The special feature of the structure is that ease to fabricate and modify the properties by varying the laser parameters could make it competitive among other nanostructures available for solar cells.

  13. Comparison of 2 wavefront-guided excimer lasers for myopic laser in situ keratomileusis: one-year results.

    PubMed

    Yu, Charles Q; Manche, Edward E

    2014-03-01

    To compare laser in situ keratomileusis (LASIK) outcomes between 2 wavefront-guided excimer laser systems in the treatment of myopia. University eye clinic, Palo Alto, California, USA. Prospective comparative case series. One eye of patients was treated with the Allegretto Wave Eye-Q system (small-spot scanning laser) and the fellow eye with the Visx Star Customvue S4 IR system (variable-spot scanning laser). Evaluations included measurement of uncorrected visual acuity, corrected visual acuity, and wavefront aberrometry. One hundred eyes (50 patients) were treated. The mean preoperative spherical equivalent (SE) refraction was -3.89 diopters (D) ± 1.67 (SD) and -4.18 ± 1.73 D in the small-spot scanning laser group and variable-spot scanning laser group, respectively. There were no significant differences in preoperative higher-order aberrations (HOAs) between the groups. Twelve months postoperatively, all eyes in the small-spot scanning laser group and 92% in the variable-spot scanning laser group were within ±0.50 D of the intended correction (P = .04). At that time, the small-spot scanning laser group had significantly less spherical aberration (0.12 versus 0.15) (P = .04) and significantly less mean total higher-order root mean square (0.33 μm versus 0.40 μm) (P = .01). Subjectively, patients reported that the clarity of night and day vision was significantly better in the eye treated with the small-spot scanning laser. The predictability and self-reported clarity of vision of wavefront-guided LASIK were better with the small-spot scanning laser. Eyes treated with the small-spot scanning laser had significantly fewer HOAs. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Experiment and numerical simulation for laser ultrasonic measurement of residual stress.

    PubMed

    Zhan, Yu; Liu, Changsheng; Kong, Xiangwei; Lin, Zhongya

    2017-01-01

    Laser ultrasonic is a most promising method for non-destructive evaluation of residual stress. The residual stress of thin steel plate is measured by laser ultrasonic technique. The pre-stress loading device is designed which can easily realize the condition of the specimen being laser ultrasonic tested at the same time in the known stress state. By the method of pre-stress loading, the acoustoelastic constants are obtained and the effect of different test directions on the results of surface wave velocity measurement is discussed. On the basis of known acoustoelastic constants, the longitudinal and transverse welding residual stresses are measured by the laser ultrasonic technique. The finite element method is used to simulate the process of surface wave detection of welding residual stress. The pulsed laser is equivalent to the surface load and the relationship between the physical parameters of the laser and the load is established by the correction coefficient. The welding residual stress of the specimen is realized by the ABAQUS function module of predefined field. The results of finite element analysis are in good agreement with the experimental method. The simple and effective numerical and experimental methods for laser ultrasonic measurement of residual stress are demonstrated. Copyright © 2016. Published by Elsevier B.V.

  15. Combination treatment with excimer laser and narrowband UVB light in vitiligo patients.

    PubMed

    Shin, Sungsik; Hann, Seung-Kyung; Oh, Sang Ho

    2016-01-01

    For the treatment of vitiligo, narrowband UVB (NBUVB) light is considered the most effective for nonsegmental vitiligo, while excimer laser treatment is commonly used for localized vitiligo. However, treatment areas may potentially be missed with excimer laser treatment. We aimed to evaluate the effect of combinational treatment with NBUVB light and excimer laser on vitiligo. All patients were first treated with NBUVB; excimer laser was then applied in conjunction with NBUVB phototherapy due to a slow response or no further improvement with continuous NBUVB treatment alone. To minimize adverse effects, a fixed dose of NBUVB was administered, and the dose of excimer laser was increased based on patient response. Among 80 patients, 54 patients showed responses after combination with excimer laser; however, 26 patients (32.5%) showed no remarkable change after combination therapy. Of the 26 patients who showed no further response, 12 patients (46.1%) presented with vitiligo on the acral areas, which are known to the least responsive sites. Our study suggests that combined treatment of NBUVB and excimer laser in vitiligo may enhance the treatment response without remarkable side effects, therefore might also increase the compliance of the patients to the treatment. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Adjunctive use of the diode laser in non-surgical periodontal therapy: exploring the controversy.

    PubMed

    Porteous, Mary Sornborger; Rowe, Dorothy J

    2014-04-01

    Despite the controversy regarding clinical efficacy, dental hygienists use the diode laser as an adjunct to non-surgical periodontal therapy. The technique to maximize successful laser therapy outcome is controversial as well. The purpose of this review is to explore the scientific foundation of the controversy surrounding the use of the diode laser as an adjunct to non-surgical periodontal therapy. Further, this paper addresses the weaknesses in study design, the heterogeneity of methodology in the published clinical studies, especially the laser parameters, and how these issues impact the collective clinical and microbial data, and thus conclusions regarding clinical efficacy. Evaluation of the literature identifies possible mechanisms that could contribute to the varied, often conflicting results among laser studies that are the foundation of the controversy surrounding clinical efficacy. These mechanisms include current paradigms of periodontal biofilm behavior, tissue response to laser therapy being dependent on tissue type and health, and that the successful therapeutic treatment window is specific to the target tissue, biofilm composition, laser wavelength, and laser energy delivered. Lastly, this paper discusses laser parameters used in the various clinical studies, and how their diversity contributes to the controversy. Although this review does not establish clinical efficacy, it does reveal the scientific foundation of the controversy and the need for standardized, well designed randomized controlled clinical trials to develop specific guidelines for using the laser as an adjunct to non-surgical periodontal therapy. Using evidence-based laser guidelines would allow dental hygienists to provide more effective non-surgical periodontal care.

  17. Model predictions of ocular injury from 1315-nm laser light

    NASA Astrophysics Data System (ADS)

    Polhamus, Garrett D.; Zuclich, Joseph A.; Cain, Clarence P.; Thomas, Robert J.; Foltz, Michael

    2003-06-01

    With the advent of future weapons systems that employ high energy lasers, the 1315 nm wavelength will present a new laser safety hazard to the armed forces. Experiments in non-human primates using this wavelength have demonstrated a range of ocular injuries, including corneal, lenticular and retinal lesions, as a function of pulse duration and spot size at the cornea. To improve our understanding of this phenomena, there is a need for a mathematical model that properly predicts these injuries and their dependence on appropriate exposure parameters. This paper describes the use of a finite difference model of laser thermal injury in the cornea and retina. The model was originally developed for use with shorter wavelength laser irradiation, and as such, requires estimation of several key parameters used in the computations. The predictions from the model are compared to the experimental data, and conclusions are drawn regarding the ability of the model to properly follow the published observations at this wavelength.

  18. Theory of Talbot lasers

    NASA Astrophysics Data System (ADS)

    Guillet de Chatellus, H.; Lacot, E.; Glastre, W.; Jacquin, O.; Hugon, O.

    2013-09-01

    We provide a theoretical study of frequency-shifted feedback (FSF) lasers, i.e., lasers with an internal frequency shifter, seeded with a monochromatic wave. The resulting spectrum consists in a set of equidistant modes, labeled by n, whose phases vary quadratically with n. We prove the emergence of a temporal fractional Talbot effect, leading to generation of Fourier-transform-limited pulses at a repetition rate tunable by the parameters of the FSF cavity (cavity length and frequency shift per round trip), and limited by the spectral bandwidth of the laser. We characterize in detail the output field of this so-called “Talbot laser” and emphasize its specific intensity fluctuations. We evidence connections with some aspects of number theory by the appearance of Gauss sums and theta series in the expression of the laser field. Our predictions are in full agreement with the experimental results published in Guillet de Chatellus [Opt. ExpressOPEXFF1094-408710.1364/OE.21.015065 21, 15065 (2013)]. Practical applications and limitations are discussed.

  19. Er:YAG laser for dentistry: basics, actual questions, and perspectives

    NASA Astrophysics Data System (ADS)

    Hibst, Raimund; Keller, Ulrich

    1994-12-01

    In recent years the dental use of the Er:YAG has found increasing interest. Most of the papers published so far concentrate on in vitro studies on cavity preparation, including the determination of ablation rates, measurements of temperature increase, microscopical analysis, and studies on the effect of water spray. The results are qualitatively in agreement and reveal a combination of high ablation efficiency and small side effects superior to other laser systems. Quantitative results, however, e.g., on ablation threshold or crater depths, sometimes differ. Some of these differences now can be explained and related to laser parameters or experimental conditions. Besides increasing the understanding on laser tissue interaction, the actual research enlarges the potential applications of the Er:YAG laser, such as for condition of enamel or dentin surfaces to enhance the bonding of composites. With the use of fibers, additional perspectives are given in periodontics and endodontics, e.g., for concrement removal or root canal preparation or sterilization.

  20. The effects of lasers on bond strength to ceramic materials: A systematic review and meta-analysis.

    PubMed

    García-Sanz, Verónica; Paredes-Gallardo, Vanessa; Mendoza-Yero, Omel; Carbonell-Leal, Miguel; Albaladejo, Alberto; Montiel-Company, José María; Bellot-Arcís, Carlos

    2018-01-01

    Lasers have recently been introduced as an alternative means of conditioning dental ceramic surfaces in order to enhance their adhesive strength to cements and other materials. The present systematic review and meta-analysis aimed to review and quantitatively analyze the available literature in order to determine which bond protocols and laser types are the most effective. A search was conducted in the Pubmed, Embase and Scopus databases for papers published up to April 2017. PRISMA guidelines for systematic review and meta-analysis were followed. Fifty-two papers were eligible for inclusion in the review. Twenty-five studies were synthesized quantitatively. Lasers were found to increase bond strength of ceramic surfaces to resin cements and composites when compared with control specimens (p-value < 0.01), whereas no significant differences were found in comparison with air-particle abraded surfaces. High variability can be observed in adhesion values between different analyses, pointing to a need to standardize study protocols and to determine the optimal parameters for each laser type.

Top