An evaluation of several methods for detecting alkali-carbonate reaction.
DOT National Transportation Integrated Search
1972-01-01
Based on the review of previous Council reports, a strategy for the use and control of potentially reactive carbonate rocks is discussed in this report, which lists the previous reports in a bibliography. Specifically, this report discusses an evalua...
Application of Probability of Crack Detection to Aircraft Systems Reliability.
DOT National Transportation Integrated Search
1993-08-31
This report describes three tasks related to probability of crack detection (POD) and aircraft systems reliablity. All three consider previous work in which crack growth simulations and crack detection data in the Service Difficulty Report (SDR) data...
Indigenous Carbonaceous Matter and Boron Associated with Halite Crystals in Nakhla
NASA Technical Reports Server (NTRS)
Thomas-Keprta, K. L.; Clemett, S. J.; McKay, D. S.; Gibson, E. K.; Wentworth, S. J.
2015-01-01
We report here the observation of indigenous organic matter spatially associated with, and in several cases embedded within, halite crystals located in alteration veins inside the Martian meteorite Nakhla. Further-more, we have also detected enrichments of boron (B) in these halites far in excess of those previously reported in bulk Martian meteorites. Boron in Martian halites has not been detected previously.
Refinement of Molecular Diagnostic Protocol of Auditory Neuropathy Spectrum Disorder
Chang, Mun Young; Kim, Ah Reum; Kim, Nayoung K.D.; Lee, Chung; Park, Woong-Yang; Choi, Byung Yoon
2015-01-01
Abstract Auditory neuropathy spectrum disorder (ANSD) is a sensorineural hearing disorder caused by dysfunction of auditory neural conduction. ANSD has a heterogeneous etiology, including genetic factors; the response to cochlear implantation significantly varies depending on the etiology. The results of timely cochlear implantation for OTOF-related ANSD (DFNB9) have been reported to be good. Therefore, identifying the causative gene of ANSD, especially OTOF, is an important issue to rehabilitate these patients. Six sporadic ANSD subjects without anatomical abnormality of the cochlear nerve, including the 4 subjects that were previously reported to be without detectable OTOF mutation, were included. We performed targeted resequencing (TRS) of known deafness genes and multiphasic bioinformatics analyses of the data that ensured detection of capture failure and structural variations. Exclusion of SNP was also double checked. The TRS data previously obtained from 2 subjects were reanalyzed. Through this study, we detected 2 mutant alleles of OTOF from 5 (83.3%) of 6 ANSD subjects. All of the 5 subjects carried at least 1 mutant allele carrying p.R1939Q. This variant was categorized as a simple SNP (rs201326023) in the database and it resided in the exon with frequent capture failures, which previously led to exclusion of this variant from eligible candidacy mistakenly. In addition, we detected a structural variation within OTOF from a previously undiagnosed ANSD subject, which was the second structural variation reported in DFNB9 subjects to date. We identify a strong etiologic homogeneity of prelingual ANSD in case of the anatomically normal cochlear nerve in Koreans and now report DFNB9 as the single overwhelming cause. Multiphasic analysis of TRS data ensuring detection of capture failure and structural variations would be expected to reveal DFNB9 from a substantial portion of previously undiagnosed ANSD subjects in Koreans. Based on our results, we propose a novel strategy that incorporates imaging studies, prevalent mutation screening and multiphasic analysis of TRS data in a stepwise manner to correctly detect DFNB9 in Koreans. PMID:26632695
Fullerenes in Allende Meteorite
NASA Technical Reports Server (NTRS)
Becker, L.; Bada, J. L.; Winans, R. E.; Bunch, T. E.
1994-01-01
The detection of fullerenes in deposits from meteor impacts has led to renewed interest in the possibility that fullerenes are present in meteorites. Although fullerenes have not previously been detected in the Murchison and Allende meteorites, the Allende meteorite is known to contain several well-ordered graphite particles which are remarkably similar in size and appearance to the fullerene-related structures carbon onions and nanotubes. We report that fullerenes are in fact present in trace amounts in the Allende meteorite. In addition to fullerenes, we detected many polycyclic aromatic hydrocarbons (PAHs) in the Allende meteorite, consistent with previous reports. In particular, we detected benzofluoranthene and corannulene (C20H10), five-membered ring structures which have been proposed as precursors to the formation of fullerene synthesis, perhaps within circumstellar envelopes or other sites in the interstellar medium.
DETECTION OF PATHOGENS IN DRINKING WATER (SEER 2)
Project investigators developed a polymerase chain reaction (PCR)-based technique to detect E. coli 0157:H7 cells in environmental samples using previously reported PCR primers for the specific detection of genes involved in biosynthesis of 0157 polysacchari...
The Incidence of Human Papillomavirus in Tanzanian Adolescent Girls Before Reported Sexual Debut.
Houlihan, Catherine F; Baisley, Kathy; Bravo, Ignacio G; Kapiga, Saidi; de Sanjosé, Silvia; Changalucha, John; Ross, David A; Hayes, Richard J; Watson-Jones, Deborah
2016-03-01
Acquisition of human papillomavirus (HPV) in women occurs predominantly through vaginal sex. However, HPV has been detected in girls reporting no previous sex. We aimed to determine incidence and risk factors for HPV acquisition in girls who report no previous sex in Tanzania, a country with high HPV prevalence and cervical cancer incidence. We followed 503 adolescent girls aged 15-16 years in Mwanza, Tanzania, with face-to-face interviews and self-administered vaginal swabs every 3 months for 18 months; 397 girls reported no sex before enrollment or during follow-up; of whom, 120 were randomly selected. Samples from enrollment, 6-, 12-, and 18-month visits were tested for 37 HPV genotypes. Incidence, clearance, point prevalence, and duration of any HPV and genotype-specific infections were calculated and associated factors were evaluated. Of 120 girls who reported no previous sex, 119 were included, contributing 438 samples. HPV was detected in 51 (11.6%) samples. The overall incidence of new HPV infections was 29.4/100 person-years (95% confidence interval: 15.9-54.2). The point prevalence of vaccine types HPV-6,-11,-16, and -18 was .9%, .9%, 2.0%, and 0%, respectively. Spending a night away from home and using the Internet were associated with incident HPV, and reporting having seen a pornographic movie was inversely associated with HPV incidence. Incident HPV infections were detected frequently in adolescent girls who reported no previous sex over 18 months. This is likely to reflect under-reporting of sex. A low-point prevalence of HPV genotypes in licensed vaccines was seen, indicating that vaccination of these girls might still be effective. Copyright © 2016 Society for Adolescent Health and Medicine. All rights reserved.
The Incidence of Human Papillomavirus in Tanzanian Adolescent Girls Before Reported Sexual Debut
Houlihan, Catherine F.; Baisley, Kathy; Bravo, Ignacio G.; Kapiga, Saidi; de Sanjosé, Silvia; Changalucha, John; Ross, David A.; Hayes, Richard J.; Watson-Jones, Deborah
2016-01-01
Purpose Acquisition of human papillomavirus (HPV) in women occurs predominantly through vaginal sex. However, HPV has been detected in girls reporting no previous sex. We aimed to determine incidence and risk factors for HPV acquisition in girls who report no previous sex in Tanzania, a country with high HPV prevalence and cervical cancer incidence. Methods We followed 503 adolescent girls aged 15–16 years in Mwanza, Tanzania, with face-to-face interviews and self-administered vaginal swabs every 3 months for 18 months; 397 girls reported no sex before enrollment or during follow-up; of whom, 120 were randomly selected. Samples from enrollment, 6-, 12-, and 18-month visits were tested for 37 HPV genotypes. Incidence, clearance, point prevalence, and duration of any HPV and genotype-specific infections were calculated and associated factors were evaluated. Results Of 120 girls who reported no previous sex, 119 were included, contributing 438 samples. HPV was detected in 51 (11.6%) samples. The overall incidence of new HPV infections was 29.4/100 person-years (95% confidence interval: 15.9–54.2). The point prevalence of vaccine types HPV-6,-11,-16, and -18 was .9%, .9%, 2.0%, and 0%, respectively. Spending a night away from home and using the Internet were associated with incident HPV, and reporting having seen a pornographic movie was inversely associated with HPV incidence. Conclusions Incident HPV infections were detected frequently in adolescent girls who reported no previous sex over 18 months. This is likely to reflect under-reporting of sex. A low-point prevalence of HPV genotypes in licensed vaccines was seen, indicating that vaccination of these girls might still be effective. PMID:26725717
Holographic particle detection
NASA Technical Reports Server (NTRS)
Bowen, Theodore
1988-01-01
The feasibility was studied of developing a novel particle track detector based on the detection of 1p-1s emission radiation from electron bubbles in liquid helium. The principles, design, construction, and initial testing of the detection system have been described in previous reports. The main obstacle encountered was the construction of the liquid-helium tight infrared windows. Despite numerous efforts in testing and redesigning the windows, the problem of window leakage at low temperature persisted. Due to limited time and resources, attention was switched to investigating the possibility of using room-temperature liquid as the detection medium. A possible mechanism was the detection of de-excitation radiation emitted from localized electrons in common liquids where electrons exhibit low mobilities, as suggested in the previous report. The purity of the liquid is critical in this method as the dissolved impurities (such as oxygen), even in trace amounts, will act as scavengers of electrons. Another mechanism is discussed whereby the formation of the superoxide ions by electron scavenging behavior of dissolved oxygen is exploited to detect the track of ionizing particles. An experiment to measure the ionization current produced in a liquid by a pulsed X-ray beam in order to study propertiies of the ions is also reported.
Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru
2017-01-01
Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection. PMID:28690568
Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru
2017-01-01
Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection.
Detection of interstellar sodium hydroxide in self-absorption toward the galactic center
NASA Technical Reports Server (NTRS)
Hollis, J. M.; Rhodes, P. J.
1982-01-01
A weak self-absorbed emission line, which is identified as the J = 4-3 transition of sodium hydroxide, has been detected in the direction of Sgr B2(OH). The correspondingly weak Sgr B2(QH) emission line U75406, previously reported as an unidentified spectral feature by other investigators, is consistent with the J = 3-2 transition of sodium hydroxide. This detection may represent the first evidence of a grain reaction formation mechanism for simple metal hydroxides. The detection of H62 Delta toward Orion A is also reported.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-12
... manufacturer of inner glass ply fracture. We are issuing this AD to detect and correct damage to the cockpit...: Discussion We received reports from the windshield manufacturer of inner glass ply fractures found on 19... reports from the windshield manufacturer of inner glass ply fracture. We are issuing this AD to detect and...
Detection of accreting gas toward HD 45677: A newly recognized, Herbig Be proto-planetary system
NASA Technical Reports Server (NTRS)
Grady, C. A.; Bjorkman, K. S.; Shepherd, D.; Schulte-Ladbeck, R. E.; Perez, M. R.; Dewinter, D.; The, P. S.
1993-01-01
We report detection of high velocity, accreting gas toward the Be star with IR excess and bipolar nebula, HD 45677. High velocity (+200 to +400 km/s), variable column density gas is visible in all IUE spectra from 1979-1992 in transitions of Si II, C II, Al III, Fe III, Si IV, and C IV. Low-velocity absorption profiles from low oscillator-strength transitions of Si II, Fe II, and Zn II exhibit double-peaked absorption profiles similar to those previously reported in optical spectra of FU Orionis objects. The UV absorption data, together with previously reported analyses of the IR excess and polarization of this object, suggest that HD 45677 is a massive, Herbig Be star with an actively accreting circumstellar, proto-planetary disk.
Optical biosensor based on liquid crystal droplets for detection of cholic acid
NASA Astrophysics Data System (ADS)
Niu, Xiaofang; Luo, Dan; Chen, Rui; Wang, Fei; Sun, Xiaowei; Dai, Haitao
2016-12-01
A highly sensitive cholic acid biosensor based on 4-cyano-4‧-penthlbiphenyl (5CB) Liquid crystal droplets in phosphate buffer saline solution was reported. A radial-to-bipolar transition of 5CB droplet would be triggered during competitive reaction of CA at the sodium dodecyl sulfate surfactant-laden 5CB droplet surface. Our liquid crystal droplet sensor is a low-cost, simple and fast method for CA detection. The detection limit (5 μM) of our method is 2.4 times lower than previously report by using liquid crystal film to detection of CA.
Toward achieving flexible and high sensitivity hexagonal boron nitride neutron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maity, A.; Grenadier, S. J.; Li, J.
Hexagonal boron nitride (h-BN) detectors have demonstrated the highest thermal neutron detection efficiency to date among solid-state neutron detectors at about 51%. We report here the realization of h-BN neutron detectors possessing one order of magnitude enhancement in the detection area but maintaining an equal level of detection efficiency of previous achievement.
Toward achieving flexible and high sensitivity hexagonal boron nitride neutron detectors
Maity, A.; Grenadier, S. J.; Li, J.; ...
2017-07-17
Hexagonal boron nitride (h-BN) detectors have demonstrated the highest thermal neutron detection efficiency to date among solid-state neutron detectors at about 51%. We report here the realization of h-BN neutron detectors possessing one order of magnitude enhancement in the detection area but maintaining an equal level of detection efficiency of previous achievement.
Shintani, H
1985-05-31
Studies were made of the analytical conditions required for indirect photometric ion chromatography using ultraviolet photometric detection (UV method) for the determination of serum cations following a previously developed serum pre-treatment. The sensitivities of the conductivity detection (CD) and UV methods and the amounts of serum cations determined by both methods were compared. Attempts to improve the sensitivity of the conventional UV method are reported. It was found that the mobile phase previously reported by Small and Miller showed no quantitative response when more than 4 mM copper(II) sulphate pentahydrate was used. As a result, there was no significant difference in the amounts of serum cations shown by the CD and UV methods. However, by adding 0.5-5 mM cobalt(II) sulphate heptahydrate, nickel(II) sulphate hexahydrate, zinc(II) sulphate heptahydrate or cobalt(II) diammonium sulphate hexahydrate to 0.5-1.5 mM copper(II) sulphate pentahydrate, higher sensitivity and a quantitative response were attained.
Simulation of Wake Vortex Radiometric Detection via Jet Exhaust Proxy
NASA Technical Reports Server (NTRS)
Daniels, Taumi S.
2015-01-01
This paper describes an analysis of the potential of an airborne hyperspectral imaging IR instrument to infer wake vortices via turbine jet exhaust as a proxy. The goal was to determine the requirements for an imaging spectrometer or radiometer to effectively detect the exhaust plume, and by inference, the location of the wake vortices. The effort examines the gas spectroscopy of the various major constituents of turbine jet exhaust and their contributions to the modeled detectable radiance. Initially, a theoretical analysis of wake vortex proxy detection by thermal radiation was realized in a series of simulations. The first stage used the SLAB plume model to simulate turbine jet exhaust plume characteristics, including exhaust gas transport dynamics and concentrations. The second stage used these plume characteristics as input to the Line By Line Radiative Transfer Model (LBLRTM) to simulate responses from both an imaging IR hyperspectral spectrometer or radiometer. These numerical simulations generated thermal imagery that was compared with previously reported wake vortex temperature data. This research is a continuation of an effort to specify the requirements for an imaging IR spectrometer or radiometer to make wake vortex measurements. Results of the two-stage simulation will be reported, including instrument specifications for wake vortex thermal detection. These results will be compared with previously reported results for IR imaging spectrometer performance.
Non-detection of HC11N towards TMC-1: constraining the chemistry of large carbon-chain molecules
NASA Astrophysics Data System (ADS)
Loomis, Ryan A.; Shingledecker, Christopher N.; Langston, Glen; McGuire, Brett A.; Dollhopf, Niklaus M.; Burkhardt, Andrew M.; Corby, Joanna; Booth, Shawn T.; Carroll, P. Brandon; Turner, Barry; Remijan, Anthony J.
2016-12-01
Bell et al. reported the first detection of the cyanopolyyne HC11N towards the cold dark cloud TMC-1; no subsequent detections have been reported towards any source. Additional observations of cyanopolyynes and other carbon-chain molecules towards TMC-1 have shown a log-linear trend between molecule size and column density, and in an effort to further explore the underlying chemical processes driving this trend, we have analysed Green Bank Telescope observations of HC9N and HC11N towards TMC-1. Although we find an HC9N column density consistent with previous values, HC11N is not detected and we derive an upper limit column density significantly below that reported in Bell et al. Using a state-of-the-art chemical model, we have investigated possible explanations of non-linearity in the column density trend. Despite updating the chemical model to better account for ion-dipole interactions, we are not able to explain the non-detection of HC11N, and we interpret this as evidence of previously unknown carbon-chain chemistry. We propose that cyclization reactions may be responsible for the depleted HC11N abundance, and that products of these cyclization reactions should be investigated as candidate interstellar molecules.
Abràmoff, Michael David; Lou, Yiyue; Erginay, Ali; Clarida, Warren; Amelon, Ryan; Folk, James C; Niemeijer, Meindert
2016-10-01
To compare performance of a deep-learning enhanced algorithm for automated detection of diabetic retinopathy (DR), to the previously published performance of that algorithm, the Iowa Detection Program (IDP)-without deep learning components-on the same publicly available set of fundus images and previously reported consensus reference standard set, by three US Board certified retinal specialists. We used the previously reported consensus reference standard of referable DR (rDR), defined as International Clinical Classification of Diabetic Retinopathy moderate, severe nonproliferative (NPDR), proliferative DR, and/or macular edema (ME). Neither Messidor-2 images, nor the three retinal specialists setting the Messidor-2 reference standard were used for training IDx-DR version X2.1. Sensitivity, specificity, negative predictive value, area under the curve (AUC), and their confidence intervals (CIs) were calculated. Sensitivity was 96.8% (95% CI: 93.3%-98.8%), specificity was 87.0% (95% CI: 84.2%-89.4%), with 6/874 false negatives, resulting in a negative predictive value of 99.0% (95% CI: 97.8%-99.6%). No cases of severe NPDR, PDR, or ME were missed. The AUC was 0.980 (95% CI: 0.968-0.992). Sensitivity was not statistically different from published IDP sensitivity, which had a CI of 94.4% to 99.3%, but specificity was significantly better than the published IDP specificity CI of 55.7% to 63.0%. A deep-learning enhanced algorithm for the automated detection of DR, achieves significantly better performance than a previously reported, otherwise essentially identical, algorithm that does not employ deep learning. Deep learning enhanced algorithms have the potential to improve the efficiency of DR screening, and thereby to prevent visual loss and blindness from this devastating disease.
Toward photostable multiplex analyte detection on a single mode planar optical waveguide
NASA Astrophysics Data System (ADS)
Mukundan, Harshini; Xie, Hongzhi; Anderson, Aaron; Grace, W. Kevin; Martinez, Jennifer S.; Swanson, Basil
2009-02-01
We have developed a waveguide-based optical biosensor for the sensitive and specific detection of biomarkers associated with disease. Our technology combines the superior optical properties of single-mode planar waveguides, the robust nature of functionalized self-assembled monolayer sensing films and the specificity of fluorescence sandwich immunoassays to detect biomarkers in complex biological samples such as serum, urine and sputum. We have previously reported the adaptation of our technology to the detection of biomarkers associated with breast cancer and anthrax. However, these approaches primarily used phospholipid bilayers as the functional film and organic dyes (ex: AlexaFluors) as the fluorescence reporter. Organic dyes are easily photodegraded and are not amenable to multiplexing because of their narrow Stokes' shift. Here we have developed strategies for conjugation of the detector antibodies with quantum dots for use in a multiplex detection platform. We have previously evaluated dihydroxylipoic acid quantum dots for the detection of a breast cancer biomarker. In this manuscript, we investigate the detection of the Bacillus anthracis protective antigen using antibodies conjugated with polymer-coated quantum dots. Kinetics of binding on the waveguide-based biosensor is reported. We compare the sensitivity of quantum dot labeled antibodies to those labeled with AlexaFluor and demonstrate the photostability of the former in our assay platform. In addition, we compare sulfydryl labeling of the antibody in the hinge region to that of nonspecific amine labeling. This is but the first step in developing a multiplex assay for such biomarkers on our waveguide platform.
NASA Technical Reports Server (NTRS)
Duyar, A.; Guo, T.-H.; Merrill, W.; Musgrave, J.
1992-01-01
In a previous study, Guo, Merrill and Duyar, 1990, reported a conceptual development of a fault detection and diagnosis system for actuation faults of the space shuttle main engine. This study, which is a continuation of the previous work, implements the developed fault detection and diagnosis scheme for the real time actuation fault diagnosis of the space shuttle main engine. The scheme will be used as an integral part of an intelligent control system demonstration experiment at NASA Lewis. The diagnosis system utilizes a model based method with real time identification and hypothesis testing for actuation, sensor, and performance degradation faults.
Ocvirk, Rok; Franklin, Keith B J; Pearson Murphy, Beverley E
2009-02-01
The performance of an antiserum to progesterone and pregnane neurosteroids was assessed in two competitive assay setups: radioimmunoassay and enzyme-linked immunoassay with colorimetric detection, both with the same limit of detection of 2 pg. The enzyme-linked immunoassay was less labor-intensive and had better precision of measurement and was used to measure progesterone and six of its ring A-reduced metabolites in rat plasma. The measured levels of allopregnanolone and progesterone were in agreement with those reported previously when measured by gas chromatography/mass spectrometry and high-performance liquid chromatography coupled with radioimmunoassay and substantially lower than those previously measured by radioimmunoassay without chromatographic separation. Both isomers of dihydroprogesterone and all four isomers of pregnanolone were detected in rat plasma, indicating that progesterone is metabolized by reduction at the C5 and C3 position of the A ring, in both alpha and beta configurations. In addition to 5beta-dihydroprogesterone and isopregnanolone, which have not been previously detected in the rat, we found considerable amounts of pregnanolone, which is neuroactive, with similar potency to that of allopregnanolone but was previously thought not to be produced in rats.
SINE sequences detect DNA fingerprints in salmonid fishes.
Spruell, P; Thorgaard, G H
1996-04-01
DNA probes homologous to two previously described salmonid short interspersed nuclear elements (SINEs) detected DNA fingerprint patterns in 14 species of salmonid fishes. The probes showed more homology to some species than to others and little homology to three nonsalmonid fishes. The DNA fingerprint patterns derived from the SINE probes are individual-specific and inherited in a Mendelian manner. Probes derived from different regions of the same SINE detect only partially overlapping banding patterns, reflecting a more complex SINE structure than has been previously reported. Like the human Alu sequence, the SINEs found in salmonids could provide useful genetic markers and primer sites for PCR-based techniques. These elements may be more desirable for some applications than traditional DNA fingerprinting probes that detect tandemly repeated arrays.
Development of an Enzyme Linked Immunosorbent Assay to Detect Chicken Parvovirus Specific Antibodies
USDA-ARS?s Scientific Manuscript database
Here we report the development and application of an enzyme linked immunosorbent assay to detect parvovirus-specific antibodies in chicken sera. We used an approach previously described for other parvoviruses to clone and express viral structural proteins in insect cells from recombinant baculovirus...
Childress, Carolyn J. Oblinger; Foreman, William T.; Connor, Brooke F.; Maloney, Thomas J.
1999-01-01
This report describes the U.S. Geological Survey National Water Quality Laboratory?s approach for determining long-term method detection levels and establishing reporting levels, details relevant new reporting conventions, and provides preliminary guidance on interpreting data reported with the new conventions. At the long-term method detection level concentration, the risk of a false positive detection (analyte reported present at the long-term method detection level when not in sample) is no more than 1 percent. However, at the long-term method detection level, the risk of a false negative occurrence (analyte reported not present when present at the long-term method detection level concentration) is up to 50 percent. Because this false negative rate is too high for use as a default 'less than' reporting level, a more reliable laboratory reporting level is set at twice the determined long-term method detection level. For all methods, concentrations measured between the laboratory reporting level and the long-term method detection level will be reported as estimated concentrations. Non-detections will be censored to the laboratory reporting level. Adoption of the new reporting conventions requires a full understanding of how low-concentration data can be used and interpreted and places responsibility for using and presenting final data with the user rather than with the laboratory. Users must consider that (1) new laboratory reporting levels may differ from previously established minimum reporting levels, (2) long-term method detection levels and laboratory reporting levels may change over time, and (3) estimated concentrations are less certain than concentrations reported above the laboratory reporting level. The availability of uncensored but qualified low-concentration data for interpretation and statistical analysis is a substantial benefit to the user. A decision to censor data after they are reported from the laboratory may still be made by the user, if merited, on the basis of the intended use of the data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukundan, Harshini; Xei, Hongshi; Anderson, Aaron S
We have developed a waveguide-based optical biosensor for the sensitive and specific detection of biomarkers associated with disease. Our technology combines the superior optical properties of single-mode planar waveguides, the robust nature of functionalized self-assembled monolayer sensing films and the specificity of fluorescence sandwich immunoassays to detect biomarkers in complex biological samples such as serum, urine and sputum. We have previously reported the adaptation of our technology to the detection of biomarkers associated with breast cancer and anthrax. However, these approaches primarily used phospholipid bilayers as the functional film and organic dyes (ex: AlexaFluors) as the fluorescence reporter. Organic dyesmore » are easily photodegraded and are not amenable to multiplexing because of their narrow Stokes' shift. Here we have developed strategies for conjugation of the detector antibodies with quantum dots for use in a multiplex detection platform. We have previously evaluated dihydroxylipoic acid quantum dots for the detection of a breast cancer biomarker. In this manuscript, we investigate the detection of the Bacillus anthracis protective antigen using antibodies conjugated with polymer-coated quantum dots. Kinetics of binding on the waveguide-based biosensor is reported. We compare the sensitivity of quantum dot labeled antibodies to those labeled with AlexaFluor and demonstrate the photostability of the former in our assay platform. In addition, we compare sulfydryl labeling of the antibody in the hinge region to that of nonspecific amine labeling. This is but the first step in developing a multiplex assay for such biomarkers on our waveguide platform.« less
Optical polarimetry of TXS 0506+056 (possible counterpart of IceCube-170922A)
NASA Astrophysics Data System (ADS)
Steele, I. A.; Jermak, H.; Copperwheat, C.
2018-03-01
ATel #11419 reports enhanced Gamma Ray Activity of TXS 0506+056 detected by Fermi-LAT on 2018 March 13. A previous Fermi-LAT high state of this source in the period 2017 Sept 15-27 was potentially associated with the Ice Cube Neutrino detection 170922A (ATel #10791).
Performance of probabilistic method to detect duplicate individual case safety reports.
Tregunno, Philip Michael; Fink, Dorthe Bech; Fernandez-Fernandez, Cristina; Lázaro-Bengoa, Edurne; Norén, G Niklas
2014-04-01
Individual case reports of suspected harm from medicines are fundamental for signal detection in postmarketing surveillance. Their effective analysis requires reliable data and one challenge is report duplication. These are multiple unlinked records describing the same suspected adverse drug reaction (ADR) in a particular patient. They distort statistical screening and can mislead clinical assessment. Many organisations rely on rule-based detection, but probabilistic record matching is an alternative. The aim of this study was to evaluate probabilistic record matching for duplicate detection, and to characterise the main sources of duplicate reports within each data set. vigiMatch™, a published probabilistic record matching algorithm, was applied to the WHO global individual case safety reports database, VigiBase(®), for reports submitted between 2000 and 2010. Reported drugs, ADRs, patient age, sex, country of origin, and date of onset were considered in the matching. Suspected duplicates for the UK, Denmark, and Spain were reviewed and classified by the respective national centre. This included evaluation to determine whether confirmed duplicates had already been identified by in-house, rule-based screening. Furthermore, each confirmed duplicate was classified with respect to the likely source of duplication. For each country, the proportions of suspected duplicates classified as confirmed duplicates, likely duplicates, otherwise related, and unrelated were obtained. The proportions of confirmed or likely duplicates that were not previously known by the national organisation were determined, and variations in the rates of suspected duplicates across subsets of reports were characterised. Overall, 2.5 % of the reports with sufficient information to be evaluated by vigiMatch were classified as suspected duplicates. The rates for the three countries considered in this study were 1.4 % (UK), 1.0 % (Denmark), and 0.7 % (Spain). Higher rates of suspected duplicates were observed for literature reports (11 %) and reports with fatal outcome (5 %), whereas a lower rate was observed for reports from consumers and non-health professionals (0.5 %). The predictive value for confirmed or likely duplicates among reports flagged as suspected duplicates by vigiMatch ranged from 86 % for the UK, to 64 % for Denmark and 33 % for Spain. The proportions of confirmed duplicates that were previously unknown to national centres ranged from 89 % for Spain, to 60 % for the UK and 38 % for Denmark, despite in-house duplicate detection processes in routine use. The proportion of unrelated cases among suspected duplicates were below 10 % for each national centre in the study. Probabilistic record matching, as implemented in vigiMatch, achieved good predictive value for confirmed or likely duplicates in each data source. Most of the false positives corresponded to otherwise related reports; less than 10 % were altogether unrelated. A substantial proportion of the correctly identified duplicates had not previously been detected by national centre activity. On one hand, vigiMatch highlighted duplicates that had been missed by rule-based methods, and on the other hand its lower total number of suspected duplicates to review improved the accuracy of manual review.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yokoyama, Yoko; Shimizu, Akira; Okada, Etsuko
Highlights: Black-Right-Pointing-Pointer We developed new method to rapidly identify COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer New PCR method using a single primer pair detected COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer This is the first report of DFSP with a novel COL1A1 breakpoint in exon 5. -- Abstract: The detection of fusion transcripts of the collagen type 1{alpha}1 (COL1A1) and platelet-derived growth factor-BB (PDGFB) genes by genetic analysis has recognized as a reliable and valuable molecular tool for the diagnosis of dermatofibrosarcoma protuberans (DFSP). To detect the COL1A1-PDGFB fusion, almost previous reports performed reverse transcription polymerase chain reaction (RT-PCR) using multiplex forward primersmore » from COL1A1. However, it has possible technical difficulties with respect to the handling of multiple primers and reagents in the procedure. The objective of this study is to establish a rapid, easy, and efficient one-step method of PCR using only a single primer pair to detect the fusion transcripts of the COL1A1 and PDGFB in DFSP. To validate new method, we compared the results of RT-PCR in five patients of DFSP between the previous method using multiplex primers and our established one-step RT-PCR using a single primer pair. In all cases of DFSP, the COL1A1-PDGFB fusion was detected by both previous method and newly established one-step PCR. Importantly, we detected a novel COL1A1 breakpoint in exon 5. The newly developed method is valuable to rapidly identify COL1A1-PDGFB fusion transcripts in DFSP.« less
2013-06-01
benefitting from rapid, automated discrimination of specific predefined signals , and is free-standing (requiring no other plugins or packages). The...previously labeled dataset, and comparing two labeled datasets. 15. SUBJECT TERMS Artifact, signal detection, EEG, MATLAB, toolbox 16. SECURITY... CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT UU 18. NUMBER OF PAGES 56 19a. NAME OF RESPONSIBLE PERSON W. David Hairston a. REPORT
Time Domain Reflectometry for Damage Detection of Laminated CFRP plate
2011-08-18
Final Report PROJECT ID: AOARD-10-4112 Title: Time Domain Reflectometry for damage detection of laminated CFRP plate Researcher: Professor Akira...From July/2010 To July/2011 Abstract Recently, high toughness Carbon Fiber Reinforced Polymer (CFRP) laminates are used to primary structures. The...large laminated CFRP structures. In the previous study, Time Domain Reflectometry (TDR) method is adopted for the detection of the fiber breakages of
Zhao, Nan; Chen, Wenfeng; Xuan, Yuming; Mehler, Bruce; Reimer, Bryan; Fu, Xiaolan
2014-01-01
The 'looked-but-failed-to-see' phenomenon is crucial to driving safety. Previous research utilising change detection tasks related to driving has reported inconsistent effects of driver experience on the ability to detect changes in static driving scenes. Reviewing these conflicting results, we suggest that drivers' increased ability to detect changes will only appear when the task requires a pattern of visual attention distribution typical of actual driving. By adding a distant fixation point on the road image, we developed a modified change blindness paradigm and measured detection performance of drivers and non-drivers. Drivers performed better than non-drivers only in scenes with a fixation point. Furthermore, experience effect interacted with the location of the change and the relevance of the change to driving. These results suggest that learning associated with driving experience reflects increased skill in the efficient distribution of visual attention across both the central focus area and peripheral objects. This article provides an explanation for the previously conflicting reports of driving experience effects in change detection tasks. We observed a measurable benefit of experience in static driving scenes, using a modified change blindness paradigm. These results have translational opportunities for picture-based training and testing tools to improve driver skill.
The use of Endopep-MS to detect multiple subtypes of botulinum neurotoxins A, B, E, and F
NASA Astrophysics Data System (ADS)
Kalb, Suzanne R.; Smith, Theresa J.; Moura, Hercules; Hill, Karen; Lou, Jianlong; Geren, Isin N.; Garcia-Rodriguez, Consuelo; Marks, James D.; Smith, Leonard A.; Pirkle, James L.; Barr, John R.
2008-12-01
Botulinum neurotoxins (BoNTs) cause the disease botulism, which can be lethal if untreated. Rapid determination of exposure to BoNT is an important public health goal. Previous work in our laboratory focused on the development of Endopep-MS, a mass spectrometry-based endopeptidase method for detecting and differentiating BoNT A-G in buffer and BoNT A, B, E, and F in clinical samples. We introduce here the use of Endopep-MS to detect non-commercial subtypes of BoNT A, B, E, and F which have been associated with botulism outbreaks. We have now tested and successfully detected 15 of the 17 known subtypes of BoNT A, B, E, and F by Endopep-MS. Extraction of BoNT A and B from a complex mixture prior to analysis is accomplished by using monoclonal antibodies specific for the catalytically inactive heavy chain of the toxin. These antibodies have high-binding affinities and do not interfere with the catalytic activity of the light chain resulting in a lower limit of detection for BoNT A and B than previously reported. We also report for the first time limits of detection for BoNT A2, A3, B2, and bivalent B using Endopep-MS.
Imported dengue from 2013 Angola outbreak: Not just serotype 1 was detected.
Abreu, Cândida; Silva-Pinto, André; Lazzara, Daniela; Sobrinho-Simões, Joana; Guimarães, João Tiago; Sarmento, António
2016-06-01
All the reports from Angola's 2013 dengue outbreak revealed serotype 1. However, previously dengue serotypes 1-4 have been reported in Africa and in 2014 serotype 4 was reported in Angola. To report dengue serotypes in patients returning from Angola during 2013 outbreak. Retrospective, cross-sectional study. We serotyped the dengue by an in house Polymerase Chain Reaction technique in randomly selected cases. From the 2013 Angola's dengue outbreak we treated 47 adult patients. None had history of past dengue. A combo kit test for dengue revealed positive NS1 antigen in 39 and IgM antibodies in 8. From 17 randomly patients tested by RNA Real Time-PCR, 11 were positive: 7 for DENV-1, 2 for DENV-2, 1 for DENV-3 (co-infected with DENV-1) and 1 for DENV-4. None had a complicated or fatal evolution. Unlike previous reports the 4 serotypes were detected, and this resulted in a different epidemiological situation, raising the risk of future outbreaks of severe dengue. Copyright © 2016 Elsevier B.V. All rights reserved.
'water splitting' by titanium exchanged zeolite A. Technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznicki, S.M.; Eyring, E.M.
1978-09-01
Visually detectable and chromatographically and mass spectrally identified hydrogen gas evolves from titanium (III) exchanged zeolite A immersed in water and illuminated with visible light. Titanium(III) exchanged zeolite X and zeolite Y do not produce this reaction. A photochemically produced, oxygenated titanium free radical (detected by electron spin resonance) not previously described is the species in the zeolite that reduces protons to molecular hydrogen. The other product of this reduction step is a nonradical, oxygenated titanium species of probable empirical formula TiO4. Heating the spent oxygenated titanium containing zeolite A under vacuum at 375 C restores over fifty percent ofmore » the free radical. Unlike previously reported systems, heating does not restore the original aquotitanium(III) species in the zeolite. Thus a means other than heating must be found to achieve a closed photochemical cycle that harnesses visible solar energy in the production of molecular hydrogen. The titanium exchanged zeolite A does, however, lend itself to a thermolysis of water previously described by Kasai and Bishop. (Author)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bachman, D., E-mail: bachman@ualberta.ca; Fedosejevs, R.; Tsui, Y. Y.
An optical damage threshold for crystalline silicon from single femtosecond laser pulses was determined by detecting a permanent change in the refractive index of the material. This index change could be detected with unprecedented sensitivity by measuring the resonant wavelength shift of silicon integrated optics microring resonators irradiated with femtosecond laser pulses at 400 nm and 800 nm wavelengths. The threshold for permanent index change at 400 nm wavelength was determined to be 0.053 ± 0.007 J/cm{sup 2}, which agrees with previously reported threshold values for femtosecond laser modification of crystalline silicon. However, the threshold for index change at 800 nm wavelength was found to be 0.044 ± 0.005 J/cm{supmore » 2}, which is five times lower than the previously reported threshold values for visual change on the silicon surface. The discrepancy is attributed to possible modification of the crystallinity of silicon below the melting temperature that has not been detected before.« less
Concentrations of the Allelochemical (+/-)-catechin IN Centaurea maculosa soils.
Perry, Laura G; Thelen, Giles C; Ridenour, Wendy M; Callaway, Ragan M; Paschke, Mark W; Vivanco, Jorge M
2007-12-01
The phytotoxin (+/-)-catechin has been proposed to mediate invasion and autoinhibition by the Eurasian plant Centaurea maculosa (spotted knapweed). The importance of (+/-)-catechin to C. maculosa ecology depends in part on whether sufficient catechin concentrations occur at appropriate times and locations within C. maculosa soil to influence neighboring plants. Previous research on catechin in C. maculosa soils has yielded conflicting results, with some studies finding high soil catechin concentrations and other, more recent studies finding little or no catechin in field soils. Here, we report the most extensive study of soil catechin concentrations to date. We examined soil catechin concentrations in 402 samples from 11 C. maculosa sites in North America sampled in consecutive months over 1 yr, excluding winter months. One site was sampled on seven dates, another was sampled twice, and the remaining nine sites were each sampled once on a range of sampling dates. Methods used were similar to those with which we previously measured high soil catechin concentrations. We detected catechin only in the site that was sampled on seven dates and only on one sampling date in that site (May 16 2006), but in all samples collected on that date. The mean soil catechin concentration on that date was 0.65 +/- 0.45 (SD) mg g(-1), comparable to previously reported high concentrations. There are a number of possible explanations for the infrequency with which we detected soil catechin in this work compared to previous studies. Differences in results could reflect spatial and temporal variation in catechin exudation or degradation, as we examined different sites in a different year from most previous studies. Also, large quantities of catechin were detected in blanks for two sampling periods in the present study, leading us to discard those data. This contamination suggests that previous reports of high catechin concentrations that did not include blanks should be viewed with caution. Our results suggest that pure catechin is only rarely present in C. maculosa bulk soils. Thus, although catechin may play a role in C. maculosa invasion, the infrequency of soil catechin that we determined in this study suggests that we cannot be as certain of its role as previous reports of high soil catechin concentrations suggested.
Progress toward polio eradication - worldwide, 2014-2015.
Hagan, José E; Wassilak, Steven G F; Craig, Allen S; Tangermann, Rudolf H; Diop, Ousmane M; Burns, Cara C; Quddus, Arshad
2015-05-22
In 1988, the World Health Assembly of the World Health Organization (WHO) resolved to eradicate polio worldwide. Wild poliovirus (WPV) transmission has been interrupted in all but three countries (Afghanistan, Nigeria, and Pakistan). No WPV type 2 cases have been detected worldwide since 1999, and the last WPV type 3 case was detected in Nigeria in November 2012; since 2012, only WPV type 1 has been detected. Circulating vaccine-derived poliovirus (cVDPV), usually type 2, continues to cause cases of paralytic polio in communities with low population immunity. In 2012, the World Health Assembly declared global polio eradication "a programmatic emergency for global public health", and in 2014, WHO declared the international spread of WPV to previously polio-free countries to be "a public health emergency of international concern". This report summarizes global progress toward polio eradication during 2014-2015 and updates previous reports. In 2014, a total of 359 WPV cases were reported in nine countries worldwide. Although reported WPV cases increased in Pakistan and Afghanistan, cases in Nigeria decreased substantially in 2014, and encouraging progress toward global WPV transmission interruption has occurred. Overcoming ongoing challenges to interruption of WPV transmission globally will require sustained programmatic enhancements, including improving the quality of supplementary immunization activities (SIAs) to interrupt transmission in Afghanistan and Pakistan and to prevent WPV exportation to polio-free countries.
From Mosques to Classrooms: Mobilizing the Community to Enhance Case Detection of Tuberculosis
Rifat, Mahfuza; Rusen, I. D.; Mahmud, Mohammad Hasan; Nayer, Israt; Islam, Akramul; Ahmed, Faruque
2008-01-01
In response to the global challenge of inadequate case detection of tuberculosis (TB), the Fund for Innovative DOTS Expansion through Local Initiatives to Stop Tuberculosis (FIDELIS) was developed in 2003 to rapidly assess and implement innovative approaches to increase the detection of new smear-positive TB cases. As previously reported, a wide range of target populations and interventions has been incorporated into successful FIDELIS projects. PMID:18633095
Detection of ice and organics on an asteroidal surface.
Rivkin, Andrew S; Emery, Joshua P
2010-04-29
Recent observations, including the discovery in typical asteroidal orbits of objects with cometary characteristics (main-belt comets, or MBCs), have blurred the line between comets and asteroids, although so far neither ice nor organic material has been detected on the surface of an asteroid or directly proven to be an asteroidal constituent. Here we report the spectroscopic detection of water ice and organic material on the asteroid 24 Themis, a detection that has been independently confirmed. 24 Themis belongs to the same dynamical family as three of the five known MBCs, and the presence of ice on 24 Themis is strong evidence that it also is present in the MBCs. We conclude that water ice is more common on asteroids than was previously thought and may be widespread in asteroidal interiors at much smaller heliocentric distances than was previously expected.
Detection and phylogenetic analysis of hepatitis E viruses from mongooses in Okinawa, Japan.
Nidaira, Minoru; Takahashi, Kazuaki; Ogura, Go; Taira, Katsuya; Okano, Shou; Kudaka, Jun; Itokazu, Kiyomasa; Mishiro, Shunji; Nakamura, Masaji
2012-12-01
Hepatitis E virus (HEV) infection has previously been reported in wild mongooses on Okinawa Island; to date however, only one HEV RNA sequence has been identified in a mongoose. Hence, this study was performed to detect HEV RNA in 209 wild mongooses on Okinawa Island. Six (2.9%) samples tested positive for HEV RNA. Phylogenetic analysis revealed that 6 HEV RNAs belonged to genotype 3 and were classified into groups A and B. In group B, mongoose-derived HEV sequences were very similar to mongoose HEV previously detected on Okinawa Island, as well as to those of a pig. This investigation emphasized the possibility that the mongoose is a reservoir animal for HEV on Okinawa Island.
Sad Facial Expressions Increase Choice Blindness
Wang, Yajie; Zhao, Song; Zhang, Zhijie; Feng, Wenfeng
2018-01-01
Previous studies have discovered a fascinating phenomenon known as choice blindness—individuals fail to detect mismatches between the face they choose and the face replaced by the experimenter. Although previous studies have reported a couple of factors that can modulate the magnitude of choice blindness, the potential effect of facial expression on choice blindness has not yet been explored. Using faces with sad and neutral expressions (Experiment 1) and faces with happy and neutral expressions (Experiment 2) in the classic choice blindness paradigm, the present study investigated the effects of facial expressions on choice blindness. The results showed that the detection rate was significantly lower on sad faces than neutral faces, whereas no significant difference was observed between happy faces and neutral faces. The exploratory analysis of verbal reports found that participants who reported less facial features for sad (as compared to neutral) expressions also tended to show a lower detection rate of sad (as compared to neutral) faces. These findings indicated that sad facial expressions increased choice blindness, which might have resulted from inhibition of further processing of the detailed facial features by the less attractive sad expressions (as compared to neutral expressions). PMID:29358926
Sad Facial Expressions Increase Choice Blindness.
Wang, Yajie; Zhao, Song; Zhang, Zhijie; Feng, Wenfeng
2017-01-01
Previous studies have discovered a fascinating phenomenon known as choice blindness-individuals fail to detect mismatches between the face they choose and the face replaced by the experimenter. Although previous studies have reported a couple of factors that can modulate the magnitude of choice blindness, the potential effect of facial expression on choice blindness has not yet been explored. Using faces with sad and neutral expressions (Experiment 1) and faces with happy and neutral expressions (Experiment 2) in the classic choice blindness paradigm, the present study investigated the effects of facial expressions on choice blindness. The results showed that the detection rate was significantly lower on sad faces than neutral faces, whereas no significant difference was observed between happy faces and neutral faces. The exploratory analysis of verbal reports found that participants who reported less facial features for sad (as compared to neutral) expressions also tended to show a lower detection rate of sad (as compared to neutral) faces. These findings indicated that sad facial expressions increased choice blindness, which might have resulted from inhibition of further processing of the detailed facial features by the less attractive sad expressions (as compared to neutral expressions).
Mutational spectrum in breast cancer associated BRCA1 and BRCA2 genes in Colombia
Gómez-Gutiérrez, Alberto; Díaz-Dussán, Natalia Andrea; Noguera-Santamaría, María Claudia; Díaz-Rincón, Diego; Casas-Gómez, María Consuelo
2017-01-01
Abstract Introduction: The risk of developing breast and ovarian cancer is higher in families that carry mutations in BRCA1 or BRCA2 genes, and timely mutation detection is critical. Objective: To identify the presence of mutations in the Colombian population and evaluate two testing strategies. Methods: From a total universe of 853 individual blood samples referred for BRCA1 and BRCA2 typing, 256 cases were analyzed by complete direct sequencing of both genes in Myriad Genetics, and the remaining 597 cases were studied by partial sequencing based on founder mutations in a PCR test designed by ourselves ("Profile Colombia"). Results: We found 107 patients carrying deleterious mutations in this group of patients, 69 (64.5%) located in BRCA1, and 38 (35.5%) in BRCA2. Overall, we detected 39 previously unreported mutations in Colombia (22 in BRCA1 and 17 in BRCA2) and only 4 out of the 6 previously reported founder mutations. Sixty four out of 597 patients (10.7%) studied by "Profile Colombia" showed mutations in BRCA1 or BRCA2, and 41/256 patients (16%) showed mutations by complete BRCA1-BRCA2 sequencing. Conclusions: The spectrum of 44 different mutations in Colombia as detected in our study is broader than the one previously reported for this country. "Profile Colombia" is a useful screening test to establish both founder and new mutations (detection rate of 10.7%) in cases with family history of breast cancer. Complete sequencing shows a detection rate of 16.0%, and should complement the study of the genetic basis of this disease. PMID:29021639
Villarroel, Camilo E.; Villanueva-Mendoza, Cristina; Orozco, Lorena; Alcántara-Ortigoza, Miguel Angel; Jiménez, Diana F.; Ordaz, Juan C.
2008-01-01
Purpose Paired box gene 6 (PAX6) heterozygous mutations are well known to cause congenital non-syndromic aniridia. These mutations produce primarily protein truncations and have been identified in approximately 40%–80% of all aniridia cases worldwide. In Mexico, there is only one previous report describing three intragenic deletions in five cases. In this study, we further analyze PAX6 variants in a group of Mexican aniridia patients and describe associated ocular findings. Methods We evaluated 30 nonrelated probands from two referral hospitals. Mutations were detected by single-strand conformation polymorphism (SSCP) and direct sequencing, and novel missense mutations and intronic changes were analyzed by in silico analysis. One intronic variation (IVS2+9G>A), which in silico analysis suggested had no pathological effects, was searched in 103 unaffected controls. Results Almost all cases exhibited phenotypes that were at the severe end of the aniridia spectrum with associated ocular alterations such as nystagmus, macular hypoplasia, and congenital cataracts. The mutation detection rate was 30%. Eight different mutations were identified: four (c.184_188dupGAGAC, c.361T>C, c.879dupC, and c.277G>A) were novel, and four (c.969C>T, IVS6+1G>C, c.853delC, and IVS7–2A>G) have been previously reported. The substitution at position 969 was observed in two patients. None of the intragenic deletions previously reported in Mexican patients were found. Most of the mutations detected predict either truncation of the PAX6 protein or conservative amino acid changes in the paired domain. We also detected two intronic non-pathogenic variations, IVS9–12C>T and IVS2+9G>A, that had been previously reported. Because the latter variation was considered potentially pathogenic, it was analyzed in 103 healthy Mexican newborns where we found an allelic frequency of 0.1116 for the A allele. Conclusions This study adds four novel mutations to the worldwide PAX6 mutational spectrum, and reaffirms the finding that c.969C>T is one of the three more frequent causal mutations in aniridia cases. It also provides evidence that IVS2+9G>A is an intronic change without pathogenic effect. PMID:18776953
NASA Astrophysics Data System (ADS)
Paik, Seoyoung; Lee, Sang-Yun; McCamey, Dane R.; Boehme, Christoph
2011-12-01
Electrically detected spin-Rabi beat oscillation of pairs of paramagnetic near interface states at the phosphorous doped (1016 cm-3) Si(111)/SiO2 interface is reported. Due to the g-factor anisotropy of the Pb center (a silicon surface dangling bond), one can tune intrapair Larmor frequency differences (Larmor separations) by orientation of the crystal with regard to an external magnetic field. Since Larmor separation governs the number of beating spin pairs, crystal orientation can control the beat current. This is used to identify spin states that are paired by mutual electronic transitions. The experiments confirm the presence of the previously reported 31P-Pb transition and provide direct experimental evidence of the previously hypothesized Pb-E' center (a near interface SiO2 bulk state) transition.
NASA Astrophysics Data System (ADS)
Zuelsdorf, R. S.; Franz, R. C.; Strangeway, R. J.; Russell, C. T.
2000-08-01
Transionospheric pulse pairs (TIPPs) as detected by the Blackbeard VHF radio instrument onboard the ALEXIS satellite have been shown to correlate with pulses detected by stations in the National Lightning Detection Network (NLDN). The short peak-to-zero time of these NLDN-detected pulses (<10 μs) are indicative of interior cloud processes, as opposed to the longer pulses associated with cloud-to-ground discharges. TIPPs are most probably generated by the same discharge responsible for narrow bipolar pulses (NBPs), which have been detected on the ground but are also believed to be generated entirely inside the cloud. Here we report on five TIPPs detected by Blackbeard that are correlated with cloud-generated pulses detected by multiple stations in the NLDN during powerful storms. Previously, a maximum of two stations at a time showed such a correlation. Given the greater area of detection, these pulses radiate more powerfully in the LF/VLF frequencies than those previously detected as TIPPs by Blackbeard. We are able to place the sources of the TIPPs in Hurricane Fausto off the coast of Mexico, and in a remnant of the same storm eight days later over Texas. The heights of the sources are higher than those previously determined for TIPPs. The higher altitudes and the greater power of the TIPP-correlating signals may be related to the intensity of the storms. Two of these five TIPPs were also correlated with the ground detection of HF signals, and the TIPPs and HF signals were determined to originate from the same source region. These HF signals are similar to those previously recorded with the field change signature of narrow positive bipolar pulses (NPBPs), but we find that both polarities are detected, four out of the five being negative. This indicates that TIPPs correlate with narrow negative bipolar pulses (NNBPs) as well as NPBPs. The detection of NNBPs, which has previously been much rarer than NPBPs, may also be related to the intensity of the storms and the resultant higher-altitude sources.
Unusual superconducting state at 49 K in electron-doped CaFe2As2 at ambient pressure
Lv, Bing; Deng, Liangzi; Gooch, Melissa; Wei, Fengyan; Sun, Yanyi; Meen, James K.; Xue, Yu-Yi; Lorenz, Bernd; Chu, Ching-Wu
2011-01-01
We report the detection of unusual superconductivity up to 49 K in single crystalline CaFe2As2 via electron-doping by partial replacement of Ca by rare-earth. The superconducting transition observed suggests the possible existence of two phases: one starting at 49 K, which has a low critical field < 4 Oe, and the other at 21 K, with a much higher critical field > 5 T. Our observations are in strong contrast to previous reports of doping or pressurizing layered compounds AeFe2As2 (or Ae122), where Ae = Ca, Sr, or Ba. In Ae122, hole-doping has been previously observed to generate superconductivity with a transition temperature (Tc) only up to 38 K and pressurization has been reported to produce superconductivity with a Tc up to 30 K. The unusual 49 K phase detected will be discussed. PMID:21911404
ERIC Educational Resources Information Center
Faughn, Carley; Marrus, Natasha; Shuman, Jeremy; Ross, Stephen R.; Constantino, John N.; Pruett, John R., Jr.; Povinelli, Daniel J.
2015-01-01
Comparative studies of social responsiveness, a core impairment in autism spectrum disorder (ASD), will enhance our understanding of typical and atypical social behavior. We previously reported a quantitative, cross-species (human-chimpanzee) social responsiveness measure, which included the development of the Chimpanzee Social Responsiveness…
In Situ CaptureRT-qPCR: A new simple and sensitive method to detect human norovirus in oysters
USDA-ARS?s Scientific Manuscript database
Human noroviruses (HuNoVs) are the major cause for the non-bacterial acute gastroenteritis worldwide. RT-qPCR is a widely used method to detect HuNoVs. However, the method is unable to discriminate between infectious and non-infectious viruses. Previously, we reported that the receptor mediated in s...
A system for distributed intrusion detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snapp, S.R.; Brentano, J.; Dias, G.V.
1991-01-01
The study of providing security in computer networks is a rapidly growing area of interest because the network is the medium over which most attacks or intrusions on computer systems are launched. One approach to solving this problem is the intrusion-detection concept, whose basic premise is that not only abandoning the existing and huge infrastructure of possibly-insecure computer and network systems is impossible, but also replacing them by totally-secure systems may not be feasible or cost effective. Previous work on intrusion-detection systems were performed on stand-alone hosts and on a broadcast local area network (LAN) environment. The focus of ourmore » present research is to extend our network intrusion-detection concept from the LAN environment to arbitarily wider areas with the network topology being arbitrary as well. The generalized distributed environment is heterogeneous, i.e., the network nodes can be hosts or servers from different vendors, or some of them could be LAN managers, like our previous work, a network security monitor (NSM), as well. The proposed architecture for this distributed intrusion-detection system consists of the following components: a host manager in each host; a LAN manager for monitoring each LAN in the system; and a central manager which is placed at a single secure location and which receives reports from various host and LAN managers to process these reports, correlate them, and detect intrusions. 11 refs., 2 figs.« less
NegBio: a high-performance tool for negation and uncertainty detection in radiology reports.
Peng, Yifan; Wang, Xiaosong; Lu, Le; Bagheri, Mohammadhadi; Summers, Ronald; Lu, Zhiyong
2018-01-01
Negative and uncertain medical findings are frequent in radiology reports, but discriminating them from positive findings remains challenging for information extraction. Here, we propose a new algorithm, NegBio, to detect negative and uncertain findings in radiology reports. Unlike previous rule-based methods, NegBio utilizes patterns on universal dependencies to identify the scope of triggers that are indicative of negation or uncertainty. We evaluated NegBio on four datasets, including two public benchmarking corpora of radiology reports, a new radiology corpus that we annotated for this work, and a public corpus of general clinical texts. Evaluation on these datasets demonstrates that NegBio is highly accurate for detecting negative and uncertain findings and compares favorably to a widely-used state-of-the-art system NegEx (an average of 9.5% improvement in precision and 5.1% in F1-score). https://github.com/ncbi-nlp/NegBio.
Ukwaja, Kingsley Nnanna; Alobu, Isaac; Ifebunandu, Ngozi Appolonia; Osakwe, Chijioke; Igwenyi, Chika
2013-01-01
Unlike previous annual WHO tuberculosis reports that reported case detection rate for only smear-positive tuberculosis cases, the 2010 report presented case detection rate for all tuberculosis cases notified in line with the current Stop TB strategy. To help us understand how tuberculosis control programmes performed in terms of detecting tuberculosis, there is need to document the trend in case detection rate for all tuberculosis cases notified in high burden countries. This evidence is currently lacking from Nigeria. Therefore, this study aimed to assess the trend in case detection rate for all tuberculosis cases notified from Ebonyi state compared to Nigeria national figures. Reports of tuberculosis cases notified between 1999 and 2009 were reviewed from the Ebonyi State Ministry of Health tuberculosis quarterly reports. Tuberculosis case detection rates were computed according to WHO guidelines. 22, 508 patients with all forms of tuberculosis were notified during the study. Case detection rate for all tuberculosis rose from 27% in 1999 to gradually reach a peak of 40% during 2007 to 2008 before a slight decline in 2009 to 38%. However, the national case detection rate for all tuberculosis cases in Nigeria rose from 7% in 1999 and progressively increased to reach a peak of 19% during 2008 and 2009. Since the introduction of DOTS in Ebonyi, the programme has achieved 40% case detection rate for all tuberculosis cases - about 20% better than national figures. However, with the current low case detection rates, alternative mechanisms are needed to achieve the current global stop- TB targets in Nigeria.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera.
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-10-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-01-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods. PMID:28974031
Epidemiology of bovine hemoprotozoa parasites in cattle and water buffalo in Vietnam.
Weerasooriya, Gayani; Sivakumar, Thillaiampalam; Lan, Dinh Thi Bich; Long, Phung Thang; Takemae, Hitoshi; Igarashi, Ikuo; Inoue, Noboru; Yokoyama, Naoaki
2016-09-01
A PCR-based survey of hemoprotozoa parasites detected Babesia bigemina, Theileria orientalis and Trypanosoma theileri among cattle and water buffalo in Vietnam, and a new Babesia sp. closely related to Babesia ovata was detected in cattle only. In addition, Theileria annulata and Trypanosoma evansi were not detected in both cattle and water buffalo. Phylogenetic analysis detected T. orientalis MPSP genotypes 3, 5, 7 and N3 in cattle and 5, 7, N1 and N2 in water buffalo. Additionally, water buffalo-derived T. theileri CATL sequences clustered together with a previously reported cattle-derived sequence from Vietnam. This is the first report of a new Babesia sp. in cattle, and T. orientalis MPSP genotype 7 and T. theileri in water buffalo in Vietnam.
Epidemiology of bovine hemoprotozoa parasites in cattle and water buffalo in Vietnam
WEERASOORIYA, Gayani; SIVAKUMAR, Thillaiampalam; LAN, Dinh Thi Bich; LONG, Phung Thang; TAKEMAE, Hitoshi; IGARASHI, Ikuo; INOUE, Noboru; YOKOYAMA, Naoaki
2016-01-01
A PCR-based survey of hemoprotozoa parasites detected Babesia bigemina, Theileria orientalis and Trypanosoma theileri among cattle and water buffalo in Vietnam, and a new Babesia sp. closely related to Babesia ovata was detected in cattle only. In addition, Theileria annulata and Trypanosoma evansi were not detected in both cattle and water buffalo. Phylogenetic analysis detected T. orientalis MPSP genotypes 3, 5, 7 and N3 in cattle and 5, 7, N1 and N2 in water buffalo. Additionally, water buffalo-derived T. theileri CATL sequences clustered together with a previously reported cattle-derived sequence from Vietnam. This is the first report of a new Babesia sp. in cattle, and T. orientalis MPSP genotype 7 and T. theileri in water buffalo in Vietnam. PMID:27149894
Cury, Maysa Heineck; Cury, Marcus Vinícius Martins; Godoy, Marcos Roberto; Matielo, Marcelo Fernando
2016-10-01
The aim of this case report is to describe the use of contrast-enhanced ultrasonography in the detection of a type II endoleak after prior embolization with Onyx. A 74-year-old male patient with hypertension previously underwent endovascular repair of a 7.1-cm infrarenal aortic aneurysm. CT angiography surveillance revealed a type II endoleak associated with aneurysm sac expansion. Selective transarterial embolization of the endoleak was performed, but it was not possible to detect the persistent endoleak using CT angiography because of image artifacts caused by Onyx. Contrast-enhanced ultrasonography enabled us to detect the persistent endoleak in this patient. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:522-526, 2016. © 2016 Wiley Periodicals, Inc.
Moreau, Robert A; Hicks, Kevin B
2006-10-18
We previously reported that heat pretreatment of corn fiber (150 degrees C, 1 h) caused a tenfold increase in the levels of extractable gamma-tocopherol. The current study was a reinvestigation of the previous effect, using improved methods (HPLC with fluorescence detection, diode-array UV detection, and mass spectrometry) for tocol analysis. Heat pretreatment did not cause an increase in the levels of any of the tocopherols or tocotrienols in corn fiber oil, but lowered the levels of three of the tocols and had no effect on the levels of the other two tocols. Heat pretreatment of corn germ had a similar effect. UV and mass spectra indicated that the peak that we had identified as gamma-tocopherol in our previous report was probably a mixture of oxidation products of triacylglycerols. Thus, heat treatment of corn germ or other corn-oil containing fractions at high temperatures leads to decreases in gamma-tocopherol, gamma-tocotrienol, and delta-tocotrienol and to the production of triacylglycerol oxidation products.
Yaylacioglu Tuncay, Fulya; Kayman Kurekci, Gülsüm; Guntekin Ergun, Sezen; Pasaoglu, Ozge Tugce; Akata, Rustu Fikret; Dincer, Pervin Rukiye
2016-01-01
Purpose To identify pathogenic variations in carbohydrate sulfotransferase 6 (CHST6) and transforming growth factor, beta-induced (TGFBI) genes in Turkish patients with corneal dystrophy (CD). Methods In this study, patients with macular corneal dystrophy (MCD; n = 18), granular corneal dystrophy type 1 (GCD1; n = 12), and lattice corneal dystrophy type 1 (LCD1; n = 4), as well as 50 healthy controls, were subjected to clinical and genetic examinations. The level of antigenic keratan sulfate (AgKS) in the serum samples of patients with MCD was determined with enzyme-linked immunosorbent assay (ELISA) to immunophenotypically subtype the patients as MCD type I and MCD type II. DNA was isolated from venous blood samples from the patients and controls. Variations were analyzed with DNA sequencing in the coding region of CHST6 in patients with MCD and exons 4 and 12 in TGFBI in patients with LCD1 and GCD1. Clinical characteristics and the detected variations were evaluated to determine any existing genotype–phenotype correlations. Results The previously reported R555W mutation in TGFBI was detected in 12 patients with GCD1, and the R124C mutation in TGFBI was detected in four patients with LCD1. Serum AgKS levels indicated that 12 patients with MCD were in subgroup I, and five patients with MCD were in subgroup II. No genetic variation was detected in the coding region of CHST6 for three patients with MCD type II. In other patients with MCD, three previously reported missense variations (c. 1A>T, c.738C>G, and c.631 C>T), three novel missense variations (c.164 T>C, c.526 G>A, c. 610 C>T), and two novel frameshift variations (c.894_895 insG and c. 462_463 delGC) were detected. These variations did not exist in the control chromosomes, 1000 Genomes, and dbSNP. Conclusions This is the first molecular analysis of TGFBI and CHST6 in Turkish patients with different types of CD. We detected previously reported, well-known hot spot mutations in TGFBI in the patients with GCD1 and LCD1. Eight likely pathogenic variations in CHST6, five of them novel, were reported in patients with MCD, which enlarges the mutational spectrum of MCD. PMID:27829782
Yaylacioglu Tuncay, Fulya; Kayman Kurekci, Gülsüm; Guntekin Ergun, Sezen; Pasaoglu, Ozge Tugce; Akata, Rustu Fikret; Dincer, Pervin Rukiye
2016-01-01
To identify pathogenic variations in carbohydrate sulfotransferase 6 ( CHST6 ) and transforming growth factor, beta-induced ( TGFBI ) genes in Turkish patients with corneal dystrophy (CD). In this study, patients with macular corneal dystrophy (MCD; n = 18), granular corneal dystrophy type 1 (GCD1; n = 12), and lattice corneal dystrophy type 1 (LCD1; n = 4), as well as 50 healthy controls, were subjected to clinical and genetic examinations. The level of antigenic keratan sulfate (AgKS) in the serum samples of patients with MCD was determined with enzyme-linked immunosorbent assay (ELISA) to immunophenotypically subtype the patients as MCD type I and MCD type II. DNA was isolated from venous blood samples from the patients and controls. Variations were analyzed with DNA sequencing in the coding region of CHST6 in patients with MCD and exons 4 and 12 in TGFBI in patients with LCD1 and GCD1. Clinical characteristics and the detected variations were evaluated to determine any existing genotype-phenotype correlations. The previously reported R555W mutation in TGFBI was detected in 12 patients with GCD1, and the R124C mutation in TGFBI was detected in four patients with LCD1. Serum AgKS levels indicated that 12 patients with MCD were in subgroup I, and five patients with MCD were in subgroup II. No genetic variation was detected in the coding region of CHST6 for three patients with MCD type II. In other patients with MCD, three previously reported missense variations (c. 1A>T, c.738C>G, and c.631 C>T), three novel missense variations (c.164 T>C, c.526 G>A, c. 610 C>T), and two novel frameshift variations (c.894_895 insG and c. 462_463 delGC) were detected. These variations did not exist in the control chromosomes, 1000 Genomes, and dbSNP. This is the first molecular analysis of TGFBI and CHST6 in Turkish patients with different types of CD. We detected previously reported, well-known hot spot mutations in TGFBI in the patients with GCD1 and LCD1. Eight likely pathogenic variations in CHST6 , five of them novel, were reported in patients with MCD, which enlarges the mutational spectrum of MCD.
Barton, James C.; Acton, Ronald T.; Leiendecker-Foster, Catherine; Lovato, Laura; Adams, Paul C.; Eckfeldt, John H.; McLaren, Christine E.; Reiss, Jacob A.; McLaren, Gordon D.; Reboussin, David M.; Gordeuk, Victor R.; Speechley, Mark R.; Press, Richard D.; Dawkins, Fitzroy W.
2013-01-01
There are few descriptions of young adults with self-reported hemochromatosis or iron overload (H/IO). We analyzed initial screening data in 7,343 HEmochromatosis and IRon Overload Screening (HEIRS) Study participants ages 25–29 years, including race/ethnicity and health information; transferrin saturation (TS) and ferritin (SF) measurements; and HFE C282Y and H63D genotypes. We used denaturing high-pressure liquid chromatography and sequencing to detect mutations in HJV, TFR2, HAMP, SLC40A1, and FTL. Fifty-one participants reported previous H/IO; 23 (45%) reported medical conditions associated with H/IO. Prevalences of reports of arthritis, diabetes, liver disease or liver cancer, heart failure, fertility problems or impotence, and blood relatives with H/IO were significantly greater in participants with previous H/IO reports than in those without. Only 7.8% of the 51 participants with previous H/IO reports had elevated TS; 13.7% had elevated SF. Only one participant had C282Y homozygosity. Three participants aged 25–29 years were heterozygous for potentially deleterious mutations in HFE2, TFR2, and HAMP promoter, respectively. Prevalences of self-reported conditions, screening iron phenotypes, and C282Y homozygosity were similar in 1,165 participants aged 30 years or greater who reported previous H/IO. We conclude that persons who report previous H/IO diagnoses in screening programs are unlikely to have H/IO phenotypes or genotypes. Previous H/IO reports in some participants could be explained by treatment that induced iron depletion before initial screening, misdiagnosis, or participant misunderstanding of their physician or the initial screening questionnaire. PMID:17726683
Wilson, Sandra R; Fink, Arlene; Verghese, Shinu; Beck, John C; Nguyen, Khue; Lavori, Philip
2007-03-01
To evaluate a new alcohol-related risk score for research use. Using data from a previously reported trial of a screening and education system for older adults (Computerized Alcohol-Related Problems Survey), secondary analyses were conducted comparing the ability of two different measures of risk to detect post-intervention group differences: the original categorical outcome measure and a new, finely grained quantitative risk score based on the same research-based risk factors. Three primary care group practices in southern California. Six hundred sixty-five patients aged 65 and older. A previously calculated, three-level categorical classification of alcohol-related risk and a newly developed quantitative risk score. Mean post-intervention risk scores differed between the three experimental conditions: usual care, patient report, and combined report (P<.001). The difference between the combined report and usual care was significant (P<.001) and directly proportional to baseline risk. The three-level risk classification did not reveal approximately 57.3% of the intervention effect detected by the risk score. The risk score also was sufficiently sensitive to detect the intervention effect within the subset of hypertensive patients (n=112; P=.001). As an outcome measure in intervention trials, the finely grained risk score is more sensitive than the trinary risk classification. The additional clinical value of the risk score relative to the categorical measure needs to be determined.
The search for Ar in the lunar atmosphere using the Lunar Reconnaissance Orbiter's LAMP instrument.
NASA Astrophysics Data System (ADS)
Cook, J. C.; Stern, S. A.; Feldman, P. D.; Gladstone, R.; Retherford, K. D.; Greathouse, T. K.; Grava, C.
2014-12-01
The Apollo 17 mass spectrometer, LACE, first measured mass 40 particles in the lunar atmosphere, and over a nine-month period, detected variations correlated with the lunar day (Hoffman et al., 1973, LPSC, 4, 2865). LACE detected a high particle density at dusk (0.6-1.0x104 cm-3), decreasing through the lunar night to a few hundred cm-3, then increasing rapidly before dawn to levels 2-4 times greater than at dusk. No daytime measurements were made due to instrument saturation. Given the LACE measurements' periodic nature, and the Ar abundance in lunar regolith samples (Kaiser, 1972, EPSL, 13, 387), it was concluded that mass 40 was likely due to Ar. Benna et al. (2014, LPSC, 45, 1535) recently reported that the Neutral Mass Spectrometer (NMS) aboard LADEE also detected Ar (mass 40) with similar diurnal profiles. We report on UV spectra of the lunar atmosphere as obtained by the Lunar Reconnaissance Orbiter (LRO). Aboard LRO is the UV-spectrograph, LAMP (Lyman Alpha Mapping Project), spanning the spectral range 575 to 1965 Å. LAMP is typically oriented toward the surface and has been mapping the Moon since September 2009. LAMP also observes the tenuous lunar atmosphere when the surface is in darkness, but the atmospheric column below LRO is illuminated. We have previously used nadir oriented twilight observations to examine the sparse lunar atmosphere (Feldman et al., 2012, Icarus, 221, 854; Cook et al., 2013, Icarus, 225, 681; Stern et al., 2013, Icarus, 226, 1210; Cook & Stern 2014, Icarus, 236, 48). In Cook et al., 2013, we reported an upper limit for Ar of 2.3x104 cm-3. Since then, we have collected additional data and refined our search method by focusing on the regions (near equator) and local times (dawn and dusk) where Ar has been reported previously. We have carefully considered effective area calibration and g-factor accuracies and find these to be unlikely explanations for the order of magnitude differences. We will report new results, which provide much lower density upper limits than any previous detection and continue to explore other potential sources of uncertainty in these results.
Automatic detection of unattended changes in room acoustics.
Frey, Johannes Daniel; Wendt, Mike; Jacobsen, Thomas
2015-01-01
Previous research has shown that the human auditory system continuously monitors its acoustic environment, detecting a variety of irregularities (e.g., deviance from prior stimulation regularity in pitch, loudness, duration, and (perceived) sound source location). Detection of irregularities can be inferred from a component of the event-related brain potential (ERP), referred to as the mismatch negativity (MMN), even in conditions in which participants are instructed to ignore the auditory stimulation. The current study extends previous findings by demonstrating that auditory irregularities brought about by a change in room acoustics elicit a MMN in a passive oddball protocol (acoustic stimuli with differing room acoustics, that were otherwise identical, were employed as standard and deviant stimuli), in which participants watched a fiction movie (silent with subtitles). While the majority of participants reported no awareness for any changes in the auditory stimulation, only one out of 14 participants reported to have become aware of changing room acoustics or sound source location. Together, these findings suggest automatic monitoring of room acoustics. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Endolithic phototrophs in built and natural stone.
Gaylarde, Christine C; Gaylarde, Peter M; Neilan, Brett A
2012-08-01
Lichens, algae and cyanobacteria have been detected growing endolithically in natural rock and in stone buildings in various countries of Australasia, Europe and Latin America. Previously these organisms had mainly been described in natural carbonaceous rocks in aquatic environments, with some reports in siliceous rocks, principally from extremophilic regions. Using various culture and microscopy methods, we have detected endoliths in siliceous stone, both natural and cut, in humid temperate and subtropical climates. Such endolithic growth leads to degradation of the stone structure, not only by mechanical means, but also by metabolites liberated by the cells. Using in vitro culture, transmission, optical and fluorescence microscopy, and confocal laser scanning microscopy, both coccoid and filamentous cyanobacteria and algae, including Cyanidiales, have been identified growing endolithically in the facades of historic buildings built from limestone, sandstone, granite, basalt and soapstone, as well as in some natural rocks. Numerically, the most abundant are small, single-celled, colonial cyanobacteria. These small phototrophs are difficult to detect by standard microscope techniques and some of these species have not been previously reported within stone.
ILS Scattering Problem and Signal Detection Model
DOT National Transportation Integrated Search
1972-02-01
The construction of a mathematical model of The Instrument Landing System (ILS) multipath problem was undertaken. This report presents the theoretical basis for any such model, a critique of previous models and newly achieve developments in ILS model...
Lin, Zhenyu; Yang, Weiqiang; Zhang, Guiyun; Liu, Qida; Qiu, Bin; Cai, Zongwei; Chen, Guonan
2011-08-28
A novel catalytic colorimetric assay assisted by nicking endonuclease signal amplification (NESA) was developed. With the signal amplification, the detection limit of the p53 target gene can be as low as 1 pM, which is nearly 5 orders of magnitude lower than that of other previously reported colorimetric DNA detection strategies based on catalytic DNAzyme.
Hepatobiliary fascioliasis: a case with unusual radiological features.
Yeşildağ, Ahmet; Senol, Altuğ; Köroğlu, Mert; Koçkar, Cem; Oyar, Orhan; Işler, Mehmet
2010-12-01
We report a case of hepatobiliary fascioliasis presenting with unusual radiological findings that have not been reported previously. Imaging studies revealed hepatic cystic pouches communicating with intrahepatic bile ducts. Snail-like, oval shaped and conglomerated echogenic particles with no acoustic shadowing, suggesting F. hepatica, were detected in these cystic pouches. In addition, secondary sclerosing cholangitis developed after fascioliasis.
Self-reported HIV antibody testing among Latino urban day laborers.
Solorio, Maria Rosa; Galvan, Frank H
2009-12-01
To identify the characteristics of male Latino urban day laborers who self-report having tested for human immunodeficiency virus (HIV). A cross-sectional survey was conducted with 356 Latino day laborers, aged 18 to 40 years, who had been sexually active in the previous 12 months, from 6 day labor sites in the City of Los Angeles. Most of the men were single, mainly from Mexico and Guatemala, and had been employed as a day laborer for fewer than 3 years; 38% had an annual income of $4000 or less. Ninety-two percent of the men reported having sex with women only, and 8% reported a history of having sex with men and women. Forty-six percent had received an HIV test in the previous 12 months and 1 person tested positive. In univariate logistic regression analyses, day laborers who were aged 26 years or older, had more than 3 years in the United States, had more than 1 year but fewer than 5 years employed as a day laborer, and had annual incomes greater than $4000 were significantly more likely to self-report HIV testing in the previous 12 months. In a multivariate logistic regression analysis, only higher annual income was found to be significantly associated with self-reported HIV testing. Interventions that target lower-income Latino day laborers are needed to promote early HIV detection. HIV detection offers individual benefits through treatment, with decreased morbidity and mortality, as well as public health benefits through decreased rates of HIV transmission in the community.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, Naoki, E-mail: naokinak@luke.or.jp; Tsunoda, Hiroko; Takahashi, Osamu
2012-11-01
Purpose: To determine the frequency and clinical significance of previously undetected incidental findings found on computed tomography (CT) simulation images for breast cancer patients. Methods and Materials: All CT simulation images were first interpreted prospectively by radiation oncologists and then double-checked by diagnostic radiologists. The official reports of CT simulation images for 881 consecutive postoperative breast cancer patients from 2009 to 2010 were retrospectively reviewed. Potentially important incidental findings (PIIFs) were defined as any previously undetected benign or malignancy-related findings requiring further medical follow-up or investigation. For all patients in whom a PIIF was detected, we reviewed the clinical recordsmore » to determine the clinical significance of the PIIF. If the findings from the additional studies prompted by a PIIF required a change in management, the PIIF was also recorded as a clinically important incidental finding (CIIF). Results: There were a total of 57 (6%) PIIFs. The 57 patients in whom a PIIF was detected were followed for a median of 17 months (range, 3-26). Six cases of CIIFs (0.7% of total) were detected. Of the six CIIFs, three (50%) cases had not been noted by the radiation oncologist until the diagnostic radiologist detected the finding. On multivariate analysis, previous CT examination was an independent predictor for PIIF (p = 0.04). Patients who had not previously received chest CT examinations within 1 year had a statistically significantly higher risk of PIIF than those who had received CT examinations within 6 months (odds ratio, 3.54; 95% confidence interval, 1.32-9.50; p = 0.01). Conclusions: The rate of incidental findings prompting a change in management was low. However, radiation oncologists appear to have some difficulty in detecting incidental findings that require a change in management. Considering cost, it may be reasonable that routine interpretations are given to those who have not received previous chest CT examinations within 1 year.« less
Piscine mycobacteriosis - Involvement of bacterial species and reflection in pathology.
Keller, C; Wenker, C; Jermann, T; Hirschi, R; Schildger, B; Meier, R; Schmidt-Posthaus, H
2018-06-01
Piscine mycobacteriosis is a lethal disease with zoonotic potential, found worldwide in both fresh and marine fish. More than 20 strains of Mycobacterium spp. are known to persist in fish so far, but the pathogenicity is currently unknown for most of them. However, M. marinum is reported as one of the most pathogenic agents for fish and is involved in zoonotic cases. We examined 47 different cases from two zoological gardens, where fish tuberculosis was identified or previously suspected during the last ten years. We collected PCR and sequencing data, which were then compared to previously collected clinical data and pathology. The clinical signs caused by Mycobacterium spp. were similar in all the cases, except for cases infected by M. marinum, which lacked the presence of skin lesions. Lesions seen in histology caused by M. marinum tended to be more acute and severe compared lesions caused by other Mycobacterium spp. The majority of M. marinum cases have been reported within marine fish. In contrast to previous studies we detected this species to be the predominant bacteria present within freshwater fish. Interestingly, we detected M. holsaticum in one of the seawater systems used in this project, being the first report of this Mycobacterium species shown to be present in a fish.
Fermi detection of delayed GeV emission from the short gamma-ray burst 081024B
Abdo, A. A.
2010-03-03
Here, we report on the detailed analysis of the high-energy extended emission from the short gamma-ray burst (GRB) 081024B detected by the Fermi Gamma-ray Space Telescope. Historically, this represents the first clear detection of temporal extended emission from a short GRB. Furthermore, the light curve observed by the Fermi Gamma-ray Burst Monitor lasts approximately 0.8 s whereas the emission in the Fermi Large Area Telescope lasts for about 3 s. Evidence of longer lasting high-energy emission associated with long bursts has been already reported by previous experiments. These observations, together with the earlier reported study of the bright short GRBmore » 090510, indicate similarities in the high-energy emission of short and long GRBs and open the path to new interpretations.« less
Maeda, Katsuhiro; Hirose, Daisuke; Okoshi, Natsuki; Shimomura, Kouhei; Wada, Yuya; Ikai, Tomoyuki; Kanoh, Shigeyoshi; Yashima, Eiji
2018-03-07
We report the first direct chirality sensing of a series of chiral hydrocarbons and isotopically chiral compounds (deuterated isotopomers), which are almost impossible to detect by conventional optical spectroscopic methods, by a stereoregular polyacetylene bearing 2,2'-biphenol-derived pendants. The polyacetylene showed a circular dichroism due to a preferred-handed helix formation in response to the hardly detectable hidden chirality of saturated tertiary or chiroptical quaternary hydrocarbons, and deuterated isotopomers. In sharp contrast to the previously reported sensory systems, the chirality detection by the polyacetylene relies on an excess one-handed helix formation induced by the chiral hydrocarbons and deuterated isotopomers via significant amplification of the chirality followed by its static memory, through which chiral information on the minute and hidden chirality can be stored as an excess of a single-handed helix memory for a long time.
Determining root correspondence between previously and newly detected objects
Paglieroni, David W.; Beer, N Reginald
2014-06-17
A system that applies attribute and topology based change detection to networks of objects that were detected on previous scans of a structure, roadway, or area of interest. The attributes capture properties or characteristics of the previously detected objects, such as location, time of detection, size, elongation, orientation, etc. The topology of the network of previously detected objects is maintained in a constellation database that stores attributes of previously detected objects and implicitly captures the geometrical structure of the network. A change detection system detects change by comparing the attributes and topology of new objects detected on the latest scan to the constellation database of previously detected objects.
Point pattern match-based change detection in a constellation of previously detected objects
Paglieroni, David W.
2016-06-07
A method and system is provided that applies attribute- and topology-based change detection to objects that were detected on previous scans of a medium. The attributes capture properties or characteristics of the previously detected objects, such as location, time of detection, detection strength, size, elongation, orientation, etc. The locations define a three-dimensional network topology forming a constellation of previously detected objects. The change detection system stores attributes of the previously detected objects in a constellation database. The change detection system detects changes by comparing the attributes and topological consistency of newly detected objects encountered during a new scan of the medium to previously detected objects in the constellation database. The change detection system may receive the attributes of the newly detected objects as the objects are detected by an object detection system in real time.
Anderson, Elizabeth S; Oxenham, Andrew J; Nelson, Peggy B; Nelson, David A
2012-12-01
Measures of spectral ripple resolution have become widely used psychophysical tools for assessing spectral resolution in cochlear-implant (CI) listeners. The objective of this study was to compare spectral ripple discrimination and detection in the same group of CI listeners. Ripple detection thresholds were measured over a range of ripple frequencies and were compared to spectral ripple discrimination thresholds previously obtained from the same CI listeners. The data showed that performance on the two measures was correlated, but that individual subjects' thresholds (at a constant spectral modulation depth) for the two tasks were not equivalent. In addition, spectral ripple detection was often found to be possible at higher rates than expected based on the available spectral cues, making it likely that temporal-envelope cues played a role at higher ripple rates. Finally, spectral ripple detection thresholds were compared to previously obtained speech-perception measures. Results confirmed earlier reports of a robust relationship between detection of widely spaced ripples and measures of speech recognition. In contrast, intensity difference limens for broadband noise did not correlate with spectral ripple detection measures, suggesting a dissociation between the ability to detect small changes in intensity across frequency and across time.
Attribute and topology based change detection in a constellation of previously detected objects
Paglieroni, David W.; Beer, Reginald N.
2016-01-19
A system that applies attribute and topology based change detection to networks of objects that were detected on previous scans of a structure, roadway, or area of interest. The attributes capture properties or characteristics of the previously detected objects, such as location, time of detection, size, elongation, orientation, etc. The topology of the network of previously detected objects is maintained in a constellation database that stores attributes of previously detected objects and implicitly captures the geometrical structure of the network. A change detection system detects change by comparing the attributes and topology of new objects detected on the latest scan to the constellation database of previously detected objects.
High-Contrast Imaging of Epsilon Eridani with Ground-Based Instruments
NASA Technical Reports Server (NTRS)
Mizuki, T.; Yamada, T.; Carson, J. C.; Kuzuhara, M.; Nakagawa, T.; Nishikawa, J.; Sitko, M. L.; Kudo, T.; Kusakabe, N.; Hashimoto, J.;
2016-01-01
Epsilon Eridani is one of the nearest solar-type stars. Its proximity and relatively young age allow high-contrast imaging observations to achieve sensitivities to planets at narrow separations down to an inner radius of approximately 5 AU. Previous observational studies of the system report a dust disk with asymmetric morphology as well as a giant planet with large orbital eccentricity, which may require another massive companion to induce the peculiar morphology and to enhance the large orbital eccentricity. In this paper, we report results from deep high-contrast imaging observations to detect the previously reported planet and search for other unseen less massive companions with Subaru/HiCIAO, Gemini-South/NICI, and VLT/NACO. No positive detection was made, but high-contrast measurements with the CH4S narrow-band filter of HiCIAO achieved sensitivities at 14.7 mag differential magnitude level, at an angular separation of 1.0''. In terms of planetary mass, as determined by cooling evolutionary models, the highest sensitivities were achieved by the Lp broad-band filter of NACO, resulting in sensitivities corresponding to 1.8, 2.8, and 4.5 M(sub jup) at the projected separation of 3 AU, if 200, 400, and 800 Myr is assumed for the age of the system, respectively. We also discuss origins of the dust disk from the detection sensitivity in the planetary mass and find that a less massive eccentric planet is preferred for disk stirring, which is consistent with the orbital parameters of epsilon Eri b claimed from the previous long-term radial velocity monitoring.
Buehler, James W; Hopkins, Richard S; Overhage, J Marc; Sosin, Daniel M; Tong, Van
2004-05-07
The threat of terrorism and high-profile disease outbreaks has drawn attention to public health surveillance systems for early detection of outbreaks. State and local health departments are enhancing existing surveillance systems and developing new systems to better detect outbreaks through public health surveillance. However, information is limited about the usefulness of surveillance systems for outbreak detection or the best ways to support this function. This report supplements previous guidelines for evaluating public health surveillance systems. Use of this framework is intended to improve decision-making regarding the implementation of surveillance for outbreak detection. Use of a standardized evaluation methodology, including description of system design and operation, also will enhance the exchange of information regarding methods to improve early detection of outbreaks. The framework directs particular attention to the measurement of timeliness and validity for outbreak detection. The evaluation framework is designed to support assessment and description of all surveillance approaches to early detection, whether through traditional disease reporting, specialized analytic routines for aberration detection, or surveillance using early indicators of disease outbreaks, such as syndromic surveillance.
Height and weight errors in aeromedical certification data.
DOT National Transportation Integrated Search
1973-06-01
The Framingham Relative Weight Index (FRWI) of obesity was described in previous reports as a screening aid for detecting susceptibility to coronary heart disease (CHD). FRWI calculation requires measured values of height and weight but the height an...
Morris, Heather C; Damon, Michael; Maule, Jake; Monaco, Lisa A; Wainwright, Norm
2012-09-01
Abstract A portable, rapid, microbial detection unit, the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS), was launched to the International Space Station (ISS) as a technology demonstration unit in December 2006. Results from the first series of experiments designed to detect Gram-negative bacteria on ISS surfaces by quantifying a single microbial biomarker lipopolysaccharide (LPS) were reported in a previous article. Herein, we report additional technology demonstration experiments expanding the on-orbit capabilities of the LOCAD-PTS to detecting three different microbial biomarkers on ISS surfaces. Six different astronauts on more than 20 occasions participated in these experiments, which were designed to test the new beta-glucan (fungal cell wall molecule) and lipoteichoic acid (LTA; Gram-positive bacterial cell wall component) cartridges individually and in tandem with the existing Limulus Amebocyte Lysate (LAL; Gram-negative bacterial LPS detection) cartridges. Additionally, we conducted the sampling side by side with the standard culture-based detection method currently used on the ISS. Therefore, we present data on the distribution of three microbial biomarkers collected from various surfaces in every module present on the ISS at the time of sampling. In accordance with our previous experiments, we determined that spacecraft surfaces known to be frequently in contact with crew members demonstrated higher values of all three microbial molecules. Key Words: Planetary protection-Spaceflight-Microbiology-Biosensor. Astrobiology 12, 830-840.
New Treatments for Drug-Resistant Epilepsy that Target Presynaptic Transmitter Release
2014-05-01
in control versus pilocarpine-treated (suffering status epilepticus ) group of animals that were injected with saline instead of levetiracetam for 1...month (Figure 1A). As previously reported we detected a significant 4.4% increase in normalized peak fluorescence in status epilepticus (SE) group...slices) (Figure A, b3). These data is consistent with our previous findings that status epilepticus induce an abnortmal increase in presynaptic
Dual wavelength imaging allows analysis of membrane fusion of influenza virus inside cells.
Sakai, Tatsuya; Ohuchi, Masanobu; Imai, Masaki; Mizuno, Takafumi; Kawasaki, Kazunori; Kuroda, Kazumichi; Yamashina, Shohei
2006-02-01
Influenza virus hemagglutinin (HA) is a determinant of virus infectivity. Therefore, it is important to determine whether HA of a new influenza virus, which can potentially cause pandemics, is functional against human cells. The novel imaging technique reported here allows rapid analysis of HA function by visualizing viral fusion inside cells. This imaging was designed to detect fusion changing the spectrum of the fluorescence-labeled virus. Using this imaging, we detected the fusion between a virus and a very small endosome that could not be detected previously, indicating that the imaging allows highly sensitive detection of viral fusion.
Moon, Sanghoon; Kim, Young Jin; Hong, Chang Bum; Kim, Dong-Joon; Lee, Jong-Young; Kim, Bong-Jo
2011-11-01
To date, hundreds of thousands of copy-number variation (CNV) data have been reported using various platforms. The proportion of Asians in these data is, however, relatively small as compared with that of other ethnic groups, such as Caucasians and Yorubas. Because of limitations in platform resolution and the high noise level in signal intensity, in most CNV studies (particularly those using single nucleotide polymorphism arrays), the average number of CNVs in an individual is less than the number of known CNVs. In this study, we ascertained reliable, common CNV regions (CNVRs) and identified actual frequency rates in the Korean population to provide more CNV information. We performed two-stage analyses for detecting structural variations with two platforms. We discovered 576 common CNVRs (88 CNV segments on average in an individual), and 87% (501 of 576) of these CNVRs overlapped by ≥1 bp with previously validated CNV events. Interestingly, from the frequency analysis of CNV profiles, 52 of 576 CNVRs had a frequency rate of <1% in the 8842 individuals. Compared with other common CNV studies, this study found six common CNVRs that were not reported in previous CNV studies. In conclusion, we propose the data-driven detection approach to discover common CNVRs including those of unreported in the previous Korean CNV study while minimizing false positives. Through our approach, we successfully discovered more common CNVRs than previous Korean CNV study and conducted frequency analysis. These results will be a valuable resource for the effective level of CNVs in the Korean population.
The frequency of previously undetectable deletions involving 3' Exons of the PMS2 gene.
Vaughn, Cecily P; Baker, Christine L; Samowitz, Wade S; Swensen, Jeffrey J
2013-01-01
Lynch syndrome is characterized by mutations in one of four mismatch repair genes, MLH1, MSH2, MSH6, or PMS2. Clinical mutation analysis of these genes includes sequencing of exonic regions and deletion/duplication analysis. However, detection of deletions and duplications in PMS2 has previously been confined to Exons 1-11 due to gene conversion between PMS2 and the pseudogene PMS2CL in the remaining 3' exons (Exons 12-15). We have recently described an MLPA-based method that permits detection of deletions of PMS2 Exons 12-15; however, the frequency of such deletions has not yet been determined. To address this question, we tested for 3' deletions in 58 samples that were reported to be negative for PMS2 mutations using previously available methods. All samples were from individuals whose tumors exhibited loss of PMS2 immunohistochemical staining without concomitant loss of MLH1 immunostaining. We identified seven samples in this cohort with deletions in the 3' region of PMS2, including three previously reported samples with deletions of Exons 13-15 (two samples) and Exons 14-15. Also detected were deletions of Exons 12-15, Exon 13, and Exon 14 (two samples). Breakpoint analysis of the intragenic deletions suggests they occurred through Alu-mediated recombination. Our results indicate that ∼12% of samples suspected of harboring a PMS2 mutation based on immunohistochemical staining, for which mutations have not yet been identified, would benefit from testing using the new methodology. Copyright © 2012 Wiley Periodicals, Inc.
Staphylococcus aureus detection in blood samples by silica nanoparticle-oligonucleotides conjugates.
Borsa, Baris A; Tuna, Bilge G; Hernandez, Frank J; Hernandez, Luiza I; Bayramoglu, Gulay; Arica, M Yakup; Ozalp, V Cengiz
2016-12-15
A fast, specific and sensitive homogeneous assay for Staphylococcus aureus detection was developed by measuring the activity of secreted nuclease from the bacteria via a modified DNA oligonucleotide. As biosensor format, an effective system, Nanokeepers as previously reported, were used for triggered release of confined fluorophores, and hence specific detection of S. aureus on nuclease activity was obtained. The interference from blood components for fluorescent quantification was eliminated by a pre-purification by aptamer-functionalized silica magnetic nanoparticles. The reported assay system was exclusively formed by nucleic acid oligos and magnetic or mesoporous silica nanoparticles, that can be used on blood samples in a stepwise manner. The assay was successfully used as a sensing platform for the specific detection of S. aureus cells as low as 682 CFU in whole blood. Copyright © 2016 Elsevier B.V. All rights reserved.
CRTS-II Detection of Increased Optical Activity from CTA 102
NASA Astrophysics Data System (ADS)
Djorgovski, S. G.; Drake, A. J.; Mahabal, A. A.; Graham, M. J.; Christensen, E.; Larson, S. M.
2017-12-01
We report the detection of significant optical brightening of FSRQ CTA 102 by CRTS-II on 2017 Dec. 8.15 UT. At that time CTA 102 was seen to have risen approximately 1.4 mags (to V_CSS = 14.15) compared with previous observations taken on 2017 Nov. 23 UT. Additional survey observations taken on 2017 Dec. 15 UT show CTA 102 at V_CSS = 14.05.
AGILE detection of prolonged gamma-ray emission from the Galactic Nova ASASSN-18fv
NASA Astrophysics Data System (ADS)
Piano, G.; Lucarelli, F.; Pittori, C.; Verrecchia, F.; Tavani, M.; Bulgarelli, A.; Parmiggiani, N.; Cardillo, M.; Ursi, A.; Minervini, G.; Donnarumma, I.; Vercellone, S.; Fioretti, V.; Pilia, M.; Gianotti, F.; Trifoglio, M.; Giuliani, A.; Mereghetti, S.; Caraveo, P.; Perotti, F.; Chen, A.; Argan, A.; Costa, E.; Del Monte, E.; Evangelista, Y.; Feroci, M.; Lazzarotto, F.; Lapshov, I.; Pacciani, L.; Soffitta, P.; Sabatini, S.; Vittorini, V.; Pucella, G.; Rapisarda, M.; Di Cocco, G.; Fuschino, F.; Galli, M.; Labanti, C.; Marisaldi, M.; Pellizzoni, A.; Trois, A.; Barbiellini, G.; Vallazza, E.; Longo, F.; Morselli, A.; Picozza, P.; Prest, M.; Lipari, P.; Zanello, D.; Cattaneo, P. W.; Rappoldi, A.; Ferrari, A.; Colafrancesco, S.; Paoletti, F.; Antonelli, A.; Giommi, P.; Salotti, L.; Valentini, G.; D'Amico, F.
2018-04-01
AGILE detected intense gamma-ray emission above 100 MeV from a source at Galactic coordinates (l, b) = (287.08, -1.08) +/- 0.6 deg (68% stat. c.l.) +/- 0.1 deg (syst.) (R.A., Dec. = 159.94, -59.84 deg, J2000), positionally consistent with the Galactic Nova ASASSN-18fv, previously reported in a gamma-ray flaring state by Fermi-LAT (ATel #11546).
Increased detection of precancerous cervical lesions with adjunctive dynamic spectral imaging.
DeNardis, Sara A; Lavin, Philip T; Livingston, Jeff; Salter, William R; James-Patrick, Nanette; Papagiannakis, Emmanouil; Olson, Christopher G; Weinberg, Lori
2017-01-01
To validate, in US community-based colposcopy clinics, previous reports of increased detection of high-grade cervical intraepithelial neoplasia (CIN2+) with biopsies selected using dynamic spectral imaging (DSI) mapping after standard colposcopy. Cross-sectional observational study of 26 colposcopists across nine clinics recruiting consecutive colposcopy patients. Standard assessment with biopsy selections was completed before seeing the DSI map which was subsequently interpreted and used for additional biopsies per clinical judgment. Primary measure was the number of women with CIN2+ detected by DSI-assisted biopsies, over those detected by standard colposcopy biopsies. A total of 887 women were recruited. After exclusions, 881 women and 1,189 biopsies were analyzed. Standard biopsy detected 78 women with CIN2+ and DSI-assisted biopsies another 34, increasing the detection rate from 8.85% to 12.71% ( p =0.00016). This was achieved with 16.16% of DSI-assisted biopsies finding CIN2+ compared to 13.24% for the preceding standard biopsies. For secondary specificity analysis, 431 women had only
Increased detection of precancerous cervical lesions with adjunctive dynamic spectral imaging
DeNardis, Sara A; Lavin, Philip T; Livingston, Jeff; Salter, William R; James-Patrick, Nanette; Papagiannakis, Emmanouil; Olson, Christopher G; Weinberg, Lori
2017-01-01
Objective To validate, in US community-based colposcopy clinics, previous reports of increased detection of high-grade cervical intraepithelial neoplasia (CIN2+) with biopsies selected using dynamic spectral imaging (DSI) mapping after standard colposcopy. Study design Cross-sectional observational study of 26 colposcopists across nine clinics recruiting consecutive colposcopy patients. Standard assessment with biopsy selections was completed before seeing the DSI map which was subsequently interpreted and used for additional biopsies per clinical judgment. Primary measure was the number of women with CIN2+ detected by DSI-assisted biopsies, over those detected by standard colposcopy biopsies. Results A total of 887 women were recruited. After exclusions, 881 women and 1,189 biopsies were analyzed. Standard biopsy detected 78 women with CIN2+ and DSI-assisted biopsies another 34, increasing the detection rate from 8.85% to 12.71% (p=0.00016). This was achieved with 16.16% of DSI-assisted biopsies finding CIN2+ compared to 13.24% for the preceding standard biopsies. For secondary specificity analysis, 431 women had only
Bruno, John G; Sivils, Jeffrey C
2017-11-01
Previously reported DNA aptamers developed against surface proteins extracted from Campylobacter jejuni were further characterized by aptamer-based Western blotting and shown to bind epitopes on proteins weighing ~16 and 60 kD from reduced C. jejuni and Campylobacter coli lysates. Proteins of these approximate weights have also been identified in traditional antibody-based Western blots of Campylobacter spp. Specificity of the capture and reporter aptamers from the previous report was further validated by aptamer-based ELISA-like (ELASA) colorimetric microplate assay. Finally, the limit of detection of the previously reported plastic-adherent aptamer-magnetic bead and aptamer-quantum dot sandwich assay (PASA) was validated by an independent food safety testing laboratory to lie between 5 and 10 C. jejuni cells per milliliter in phosphate buffered saline and repeatedly frozen and thawed chicken rinsate. Such ultrasensitive and rapid (30 min) aptamer-based assays could provide alternative or additional screening tools to enhance food safety testing for Campylobacter and other foodborne pathogens.
Detection of Adverse Drug Reactions using Medical Named Entities on Twitter.
MacKinlay, Andrew; Aamer, Hafsah; Yepes, Antonio Jimeno
2017-01-01
Adverse Drug Reactions (ADRs) are unintentional reactions caused by a drug or combination of drugs taken by a patient. The current ADR reporting systems inevitably have delays in reporting such events. The broad scope of social media conversations on sites such as Twitter means that inevitably health-related topics will be covered. This means that these sites could then be used to detect potentially novel ADRs with less latency for subsequent further investigation. In this work, we investigate ADR surveillance using a large corpus of Twitter data, containing around 50 billion tweets spanning 3 years (2012-2014), and evaluate against over 3000 drugs reported in the FAERS database. This is both a larger corpus and broader selection of drugs than previous work in the domain. We compare the ADRs identified using our method to the FDA Adverse Event Reporting System (FAERS) database of ADRs reported using more traditional techniques, and find that Twitter is a useful resource for ADR detection up to 72% micro-averaged precision. Micro-averaged recall of 6% is achievable using only 10% of Twitter, indicating that with a higher-volume or targeted feed it would be possible to detect a large percentage of ADRs.
The first cases of Lassa fever in Ghana.
Dzotsi, E K; Ohene, S-A; Asiedu-Bekoe, F; Amankwa, J; Sarkodie, B; Adjabeng, M; Thouphique, A M; Ofei, A; Oduro, J; Atitogo, D; Bonney, J H K; Paintsil, S C N; Ampofo, W
2012-09-01
Lassa fever is a zoonotic disease endemic in West Africa but with no previous case reported in Ghana. We describe the first two laboratory confirmed cases of Lassa fever from the Ashanti Region of Ghana detected in October and December, 2011.
NASA Astrophysics Data System (ADS)
Lomax, Jamie R.; Peters, Matthew; Wisniewski, John; Dalcanton, Julianne; Williams, Benjamin; Lutz, Julie; Choi, Yumi; Sigut, Aaron
2017-11-01
Massive stars are intrinsically rare and therefore present a challenge to understand from a statistical perspective, especially within the Milky Way. We recently conducted follow-up observations to the Panchromatic Hubble Andromeda Treasury (PHAT) survey that were designed to detect more than 10,000 emission line stars, including WRs, by targeting regions in M31 previously known to host large numbers of young, massive clusters and very young stellar populations. Because of the existing PHAT data, we are able to derive an effective temperature, bolarimetric luminosity, and extinction for each of our detected stars. We report on preliminary results of the massive star population of our dataset and discuss how our results compare to previous studies of massive stars in M31.
Daschner, A; Vega de la Osada, F; Pascual, C Y
2005-01-01
The ubiquitous fish-nematode Anisakis simplex produces acute urticaria or angioedema in the course of gastro-allergic anisakiasis. We studied the relationship between this nematode and chronic urticaria (CU), as well as the clinical usefulness of measuring specific IgG4 in A. simplex-sensitized patients with CU. First, the prevalence of sensitization to A. simplex was estimated in 135 consecutive CU patients and the result was compared with known data about sensitization in a healthy population. Then, clinical response to a 2-month diet without fish was analyzed in 76 CU patients. The improvement rate in patients with and without sensitization to A. simplex was compared. Finally, the improvement rate, other clinical data and specific immunoglobulins in sensitized patients with and without detectable specific IgG4 were compared. a) The A. simplex sensitization rate in CU patients was 52.6 % compared with a known prevalence of between 16 and 20 % in our region. b) Of 65 sensitized patients, 52 experienced clinical improvement after the diet compared with only three of 11 patients without sensitization to A. simplex (p = 0.001). c) Of 43 patients with detectable specific IgG4, 38 showed clinical improvement compared with only 14 of 22 patients without detectable IgG4 (p = 0.02). Eight of nine patients with previous fish-associated cutaneous symptoms had detectable specific IgG4 compared with 15 of 32 patients who reported no previous fish-associated symptoms or acute urticaria (p = 0.03). Our results indicate that A. simplex is a possibly widespread etiologic agent able to induce CU. This parasite model constitutes the first report that associates an infectious agent with CU on a large scale. The detection of IgG4 antibodies reflects a previous acute parasitic infection and a temporary diet without fish improves symptoms in most patients with detectable specific IgG4.
Photon-number-resolving SSPDs with system detection efficiency over 50% at telecom range
NASA Astrophysics Data System (ADS)
Zolotov, P.; Divochiy, A.; Vakhtomin, Yu.; Moshkova, M.; Morozov, P.; Seleznev, V.; Smirnov, K.
2018-02-01
We used technology of making high-efficiency superconducting single-photon detectors as a basis for improvement of photon-number-resolving devices. By adding optical cavity and using an improved NbN superconducting film, we enhanced previously reported system detection efficiency at telecom range for such detectors. Our results show that implementation of optical cavity helps to develop four-section device with quantum efficiency over 50% at 1.55 µm. Performed experimental studies of detecting multi-photon optical pulses showed irregularities over defining multi-photon through single-photon quantum efficiency.
Septiningsih, E M; Prasetiyono, J; Lubis, E; Tai, T H; Tjubaryat, T; Moeljopawiro, S; McCouch, S R
2003-11-01
A BC(2)F(2) population developed from an interspecific cross between Oryza sativa (cv IR64) and O. rufipogon (IRGC 105491) was used in an advanced backcross QTL analysis to identify and introduce agronomically useful genes from this wild relative into the cultivated gene pool. The objectives of this study were: (1) to identify putative yield and yield component QTLs that can be useful to improve the elite cultivar IR64; (2) to compare the QTLs within this study with previously reported QTLs in rice as the basis for identifying QTLs that are stable across different environments and genetic backgrounds; and (3) to compare the identified QTLs with previously reported QTLs from maize to examine the degree of QTL conservation across the grass family. Two hundred eighty-five families were evaluated in two field environments in Indonesia, with two replications each, for 12 agronomic traits. A total of 165 markers consisting of 131 SSRs and 34 RFLPs were used to construct the genetic linkage map. By employing interval mapping and composite interval mapping, 42 QTLs were identified. Despite its inferior performance, 33% of the QTL alleles originating from O. rufipogon had a beneficial effect for yield and yield components in the IR64 background. Twenty-two QTLs (53.4%) were located in similar regions as previously reported rice QTLs, suggesting the existence of stable QTLs across genetic backgrounds and environments. Twenty QTLs (47.6%) were exclusively detected in this study, uncovering potentially novel alleles from the wild, some of which might improve the performance of the tropical indica variety IR64. Additionally, several QTLs for plant height, grain weight, and flowering time detected in this study corresponded to homeologous regions in maize containing previously detected maize QTLs for these traits.
Investigating prior probabilities in a multiple hypothesis test for use in space domain awareness
NASA Astrophysics Data System (ADS)
Hardy, Tyler J.; Cain, Stephen C.
2016-05-01
The goal of this research effort is to improve Space Domain Awareness (SDA) capabilities of current telescope systems through improved detection algorithms. Ground-based optical SDA telescopes are often spatially under-sampled, or aliased. This fact negatively impacts the detection performance of traditionally proposed binary and correlation-based detection algorithms. A Multiple Hypothesis Test (MHT) algorithm has been previously developed to mitigate the effects of spatial aliasing. This is done by testing potential Resident Space Objects (RSOs) against several sub-pixel shifted Point Spread Functions (PSFs). A MHT has been shown to increase detection performance for the same false alarm rate. In this paper, the assumption of a priori probability used in a MHT algorithm is investigated. First, an analysis of the pixel decision space is completed to determine alternate hypothesis prior probabilities. These probabilities are then implemented into a MHT algorithm, and the algorithm is then tested against previous MHT algorithms using simulated RSO data. Results are reported with Receiver Operating Characteristic (ROC) curves and probability of detection, Pd, analysis.
Multichannel waveguides for the simultaneous detection of disease biomarkers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukundan, Harshini; Price, Dominique Z; Grace, Wynne K
2009-01-01
The sensor team at the Los Alamos National Laboratory has developed a waveguide-based optical biosensor that has previously been used for the detection of biomarkers associated with diseases such as tuberculosis, breast cancer, anthrax and influenza in complex biological samples (e.g., serum and urine). However, no single biomarker can accurately predict disease. To address this issue, we developed a multiplex assay for the detection of components of the Bacillus anthracis lethal toxin on single mode planar optical waveguides with tunable quantum dots as the fluorescence reporter. This limited ability to multiplex is still insufficient for accurate detection of disease ormore » for monitoring prognosis. In this manuscript, we demonstrate for the first time, the design, fabrication and successful evaluation of a multichannel planar optical waveguide for the simultaneous detection of at least three unknown samples in quadruplicate. We demonstrate the simultaneous, rapid (30 min), quantitative (with internal standard) and sensitive (limit of detection of 1 pM) detection of protective antigen and lethal factor of Bacillus anthracis in complex biological samples (serum) using specific monoclonal antibodies labeled with quantum dots as the fluorescence reporter.« less
Drug-induced hypersensitivity syndrome associated with Epstein-Barr virus infection.
Descamps, V; Mahe, E; Houhou, N; Abramowitz, L; Rozenberg, F; Ranger-Rogez, S; Crickx, B
2003-05-01
Association of drug-induced hypersensitivity syndrome with viral infection is debated. Human herpesvirus 6 (HHV-6) reactivation has been the most frequently reported infection associated with this syndrome. However, a case of cytomegalovirus (CMV) infection was recently described associated with anticonvulsant-induced hypersensitivity syndrome. We report a case of severe allopurinol-induced hypersensitivity syndrome with pancreatitis associated with Epstein-Barr virus (EBV) infection. Active EBV infection was demonstrated in two consecutive serum samples by the presence of anti-EBV early antigen (EA) IgM antibodies and an increase in anti-EBV EA IgG antibodies, whereas no anti-EBV nuclear antigen IgG antibodies were detected. EBV DNA was detected by polymerase chain reaction (PCR) in peripheral blood mononuclear cells. Reactivation of HHV-6 was suggested only by the presence of anti-HHV-6 IgM antibodies, but HHV-6 DNA was not detected by PCR in the serum. Other viral investigations showed previous infection (CMV, rubella, measles, parvovirus B19), immunization after vaccination (hepatitis B virus), or absence of previous infection (hepatitis C virus, human immunodeficiency virus). We suggest that EBV infection may participate in some cases, as do the other herpesviruses HHV-6 or CMV, in the development of drug-induced hypersensitivity syndrome.
The Role of Attention in the Binding of Surface Features to Locations
Hyun, Joo-seok; Woodman, Geoffrey F.; Luck, Steven J.
2013-01-01
Previous studies have proposed that attention is not necessary for detecting simple features but is necessary for binding them to spatial locations. The present study tested this hypothesis, using the N2pc component of the event-related potential waveform as a measure of the allocation of attention. A simple feature detection condition, in which observers reported whether a target color was present or not, was compared with feature-location binding conditions, in which observers reported the location of the target color. A larger N2pc component was observed in the binding conditions than in the detection condition, indicating that additional attentional resources are needed to bind a feature to a location than to detect the feature independently of its location. This finding supports theories of attention in which attention plays a special role in binding features. PMID:24235876
Anderson, Elizabeth S.; Oxenham, Andrew J.; Nelson, Peggy B.; Nelson, David A.
2012-01-01
Measures of spectral ripple resolution have become widely used psychophysical tools for assessing spectral resolution in cochlear-implant (CI) listeners. The objective of this study was to compare spectral ripple discrimination and detection in the same group of CI listeners. Ripple detection thresholds were measured over a range of ripple frequencies and were compared to spectral ripple discrimination thresholds previously obtained from the same CI listeners. The data showed that performance on the two measures was correlated, but that individual subjects’ thresholds (at a constant spectral modulation depth) for the two tasks were not equivalent. In addition, spectral ripple detection was often found to be possible at higher rates than expected based on the available spectral cues, making it likely that temporal-envelope cues played a role at higher ripple rates. Finally, spectral ripple detection thresholds were compared to previously obtained speech-perception measures. Results confirmed earlier reports of a robust relationship between detection of widely spaced ripples and measures of speech recognition. In contrast, intensity difference limens for broadband noise did not correlate with spectral ripple detection measures, suggesting a dissociation between the ability to detect small changes in intensity across frequency and across time. PMID:23231122
Palanga, Essowè; Filloux, Denis; Martin, Darren P; Fernandez, Emmanuel; Gargani, Daniel; Ferdinand, Romain; Zabré, Jean; Bouda, Zakaria; Neya, James Bouma; Sawadogo, Mahamadou; Traore, Oumar; Peterschmitt, Michel; Roumagnac, Philippe
2016-01-01
Cowpea, (Vigna unguiculata L. (Walp)) is an annual tropical grain legume. Often referred to as "poor man's meat", cowpea is one of the most important subsistence legumes cultivated in West Africa due to the high protein content of its seeds. However, African cowpea production can be seriously constrained by viral diseases that reduce yields. While twelve cowpea-infecting viruses have been reported from Africa, only three of these have so-far been reported from Burkina Faso. Here we use a virion-associated nucleic acids (VANA)-based metagenomics method to screen for the presence of cowpea viruses from plants collected from the three agro-climatic zones of Burkina Faso. Besides the three cowpea-infecting virus species which have previously been reported from Burkina Faso (Cowpea aphid borne mosaic virus [Family Potyviridae], the Blackeye cowpea mosaic virus-a strain of Bean common mosaic virus-[Family Potyviridae] and Cowpea mottle virus [Family Tombusviridae]) five additional viruses were identified: Southern cowpea mosaic virus (Sobemovirus genus), two previously uncharacterised polerovirus-like species (Family Luteoviridae), a previously uncharacterised tombusvirus-like species (Family Tombusviridae) and a previously uncharacterised mycotymovirus-like species (Family Tymoviridae). Overall, potyviruses were the most prevalent cowpea viruses (detected in 65.5% of samples) and the Southern Sudan zone of Burkina Faso was found to harbour the greatest degrees of viral diversity and viral prevalence. Partial genome sequences of the two novel polerovirus-like and tombusvirus-like species were determined and RT-PCR primers were designed for use in Burkina Faso to routinely detect all of these cowpea-associated viruses.
Palanga, Essowè; Filloux, Denis; Martin, Darren P.; Fernandez, Emmanuel; Gargani, Daniel; Ferdinand, Romain; Zabré, Jean; Bouda, Zakaria; Neya, James Bouma; Sawadogo, Mahamadou; Traore, Oumar; Peterschmitt, Michel; Roumagnac, Philippe
2016-01-01
Cowpea, (Vigna unguiculata L. (Walp)) is an annual tropical grain legume. Often referred to as “poor man’s meat”, cowpea is one of the most important subsistence legumes cultivated in West Africa due to the high protein content of its seeds. However, African cowpea production can be seriously constrained by viral diseases that reduce yields. While twelve cowpea-infecting viruses have been reported from Africa, only three of these have so-far been reported from Burkina Faso. Here we use a virion-associated nucleic acids (VANA)-based metagenomics method to screen for the presence of cowpea viruses from plants collected from the three agro-climatic zones of Burkina Faso. Besides the three cowpea-infecting virus species which have previously been reported from Burkina Faso (Cowpea aphid borne mosaic virus [Family Potyviridae], the Blackeye cowpea mosaic virus—a strain of Bean common mosaic virus—[Family Potyviridae] and Cowpea mottle virus [Family Tombusviridae]) five additional viruses were identified: Southern cowpea mosaic virus (Sobemovirus genus), two previously uncharacterised polerovirus-like species (Family Luteoviridae), a previously uncharacterised tombusvirus-like species (Family Tombusviridae) and a previously uncharacterised mycotymovirus-like species (Family Tymoviridae). Overall, potyviruses were the most prevalent cowpea viruses (detected in 65.5% of samples) and the Southern Sudan zone of Burkina Faso was found to harbour the greatest degrees of viral diversity and viral prevalence. Partial genome sequences of the two novel polerovirus-like and tombusvirus-like species were determined and RT-PCR primers were designed for use in Burkina Faso to routinely detect all of these cowpea-associated viruses. PMID:27764211
Genome-Wide Detection of CNVs and Their Association with Meat Tenderness in Nelore Cattle.
Silva, Vinicius Henrique da; Regitano, Luciana Correia de Almeida; Geistlinger, Ludwig; Pértille, Fábio; Giachetto, Poliana Fernanda; Brassaloti, Ricardo Augusto; Morosini, Natália Silva; Zimmer, Ralf; Coutinho, Luiz Lehmann
2016-01-01
Brazil is one of the largest beef producers and exporters in the world with the Nelore breed representing the vast majority of Brazilian cattle (Bos taurus indicus). Despite the great adaptability of the Nelore breed to tropical climate, meat tenderness (MT) remains to be improved. Several factors including genetic composition can influence MT. In this article, we report a genome-wide analysis of copy number variation (CNV) inferred from Illumina® High Density SNP-chip data for a Nelore population of 723 males. We detected >2,600 CNV regions (CNVRs) representing ≈6.5% of the genome. Comparing our results with previous studies revealed an overlap in ≈1400 CNVRs (>50%). A total of 1,155 CNVRs (43.6%) overlapped 2,750 genes. They were enriched for processes involving guanosine triphosphate (GTP), previously reported to influence skeletal muscle physiology and morphology. Nelore CNVRs also overlapped QTLs for MT reported in other breeds (8.9%, 236 CNVRs) and from a previous study with this population (4.1%, 109 CNVRs). Two CNVRs were also proximal to glutathione metabolism genes that were previously associated with MT. Genome-wide association study of CN state with estimated breeding values derived from meat shear force identified 6 regions, including a region on BTA3 that contains genes of the cAMP and cGMP pathway. Ten CNVRs that overlapped regions associated with MT were successfully validated by qPCR. Our results represent the first comprehensive CNV study in Bos taurus indicus cattle and identify regions in which copy number changes are potentially of importance for the MT phenotype.
Watson, Sarah; Chandler, Rebecca E; Taavola, Henric; Härmark, Linda; Grundmark, Birgitta; Zekarias, Alem; Star, Kristina; van Hunsel, Florence
2018-02-01
Patient reporting in pharmacovigilance is important and contributes to signal detection. However, descriptions of methodologies for using patient reports in signal detection are scarce, and published experiences of how patient reports are used in pharmacovigilance are limited to a few individual countries. Our objective was to explore the contribution of patient reports to global signal detection in VigiBase. Data were retrieved from VigiBase in September 2016. Drug-event-combination series were restricted to those with >50% patient reports, defined as reporter type "Consumer/non-health professional" per E2B reporting standard. vigiRank was applied to patient reports to prioritize combinations for assessment. Product information for healthcare professionals (HCPs) as well as patient information leaflets (PILs) were used as reference for information on adverse drug reactions (ADRs). Staff from the Uppsala Monitoring Centre and the Netherlands Pharmacovigilance Centre Lareb categorized the combinations. Potential signals proceeded to a more in-depth clinical review to determine whether the safety concern should be communicated as a "signal." Of the 212 combinations assessed, 20 (9%) resulted in eight signals communicated within the World Health Organization (WHO) programme for international drug monitoring. Review of PILs revealed insufficient ADR descriptions for patients and examples of poor consistency with product information for HCPs. Patient narratives provided details regarding the experience and impact of ADRs and evidence that patients make causality and personal risk assessments. Safety concerns described in patient reports can be identified in a global database including previously unknown ADRs as well as new aspects of known ADRs. Patient reports provide unique information valuable in signal assessment and should be included in signal detection. Novel approaches to highlighting patient reports in statistical signal detection can further improve the contribution of patient reports to pharmacovigilance.
Yusof, Mohammed F; Eltahir, Yassir M; Serhan, Wissam S; Hashem, Farouk M; Elsayed, Elsaeid A; Marzoug, Bahaaeldin A; Abdelazim, Assem Si; Bensalah, Oum Keltoum A; Al Muhairi, Salama S
2015-06-01
High seroprevalence of Middle East respiratory syndrome corona virus (MERS-CoV) in dromedary camels has been previously reported in United Arab Emirates (UAE). However, the molecular detection of the virus has never been reported before in UAE. Of the 7,803 nasal swabs tested in the epidemiological survey, MERS-CoV nucleic acid was detected by real-time PCR in a total of 126 (1.6 %) camels. Positive camels were detected at the borders with Saudi Arabia and Oman and in camels' slaughter houses. MERS-CoV partial sequences obtained from UAE camels were clustering with human- and camel-derived MERS-CoV sequences in the same geographic area. Results provide further evidence of MERS-CoV zoonosis.
Detection of tunnel excavation using fiber optic reflectometry: experimental validation
NASA Astrophysics Data System (ADS)
Linker, Raphael; Klar, Assaf
2013-06-01
Cross-border smuggling tunnels enable unmonitored movement of people and goods, and pose a severe threat to homeland security. In recent years, we have been working on the development of a system based on fiber- optic Brillouin time domain reflectometry (BOTDR) for detecting tunnel excavation. In two previous SPIE publications we have reported the initial development of the system as well as its validation using small-scale experiments. This paper reports, for the first time, results of full-scale experiments and discusses the system performance. The results confirm that distributed measurement of strain profiles in fiber cables buried at shallow depth enable detection of tunnel excavation, and by proper data processing, these measurements enable precise localization of the tunnel, as well as reasonable estimation of its depth.
Enterobius vermicularis: Can it be a possible pathogen in Bartholin gland abscess formation?
Dönmez, Melahat Emine; Özlü, Tülay; Yılmaz, Fahri; Ayaz, Erol
2014-01-01
The most frequent disorders of the Bartholin glands are cysts or abscesses. Bartholin gland abscesses occur generally as a result of polymicrobial infections or agents that cause sexually transmitted diseases. But as far as we know, no parasite has been previously reported among the infectious agents that are detected from the abscesses of the Bartholin gland. Here, we report a 45-year-old woman, in the Bartholin abscess aspirate of whom Enterobius vermicularis eggs were detected in between the inflammatory infiltrate by cytological examination. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.
Detection of Novel Sequences Related to African Swine Fever Virus in Human Serum and Sewage▿ †
Loh, Joy; Zhao, Guoyan; Presti, Rachel M.; Holtz, Lori R.; Finkbeiner, Stacy R.; Droit, Lindsay; Villasana, Zoilmar; Todd, Collin; Pipas, James M.; Calgua, Byron; Girones, Rosina; Wang, David; Virgin, Herbert W.
2009-01-01
The family Asfarviridae contains only a single virus species, African swine fever virus (ASFV). ASFV is a viral agent with significant economic impact due to its devastating effects on populations of domesticated pigs during outbreaks but has not been reported to infect humans. We report here the discovery of novel viral sequences in human serum and sewage which are clearly related to the asfarvirus family but highly divergent from ASFV. Detection of these sequences suggests that greater genetic diversity may exist among asfarviruses than previously thought and raises the possibility that human infection by asfarviruses may occur. PMID:19812170
Genovar: a detection and visualization tool for genomic variants.
Jung, Kwang Su; Moon, Sanghoon; Kim, Young Jin; Kim, Bong-Jo; Park, Kiejung
2012-05-08
Along with single nucleotide polymorphisms (SNPs), copy number variation (CNV) is considered an important source of genetic variation associated with disease susceptibility. Despite the importance of CNV, the tools currently available for its analysis often produce false positive results due to limitations such as low resolution of array platforms, platform specificity, and the type of CNV. To resolve this problem, spurious signals must be separated from true signals by visual inspection. None of the previously reported CNV analysis tools support this function and the simultaneous visualization of comparative genomic hybridization arrays (aCGH) and sequence alignment. The purpose of the present study was to develop a useful program for the efficient detection and visualization of CNV regions that enables the manual exclusion of erroneous signals. A JAVA-based stand-alone program called Genovar was developed. To ascertain whether a detected CNV region is a novel variant, Genovar compares the detected CNV regions with previously reported CNV regions using the Database of Genomic Variants (DGV, http://projects.tcag.ca/variation) and the Single Nucleotide Polymorphism Database (dbSNP). The current version of Genovar is capable of visualizing genomic data from sources such as the aCGH data file and sequence alignment format files. Genovar is freely accessible and provides a user-friendly graphic user interface (GUI) to facilitate the detection of CNV regions. The program also provides comprehensive information to help in the elimination of spurious signals by visual inspection, making Genovar a valuable tool for reducing false positive CNV results. http://genovar.sourceforge.net/.
Enhanced olfactory sensitivity in autism spectrum conditions.
Ashwin, Chris; Chapman, Emma; Howells, Jessica; Rhydderch, Danielle; Walker, Ian; Baron-Cohen, Simon
2014-01-01
People with autism spectrum conditions (ASC) report heightened olfaction. Previous sensory experiments in people with ASC have reported hypersensitivity across visual, tactile, and auditory domains, but not olfaction. The aims of the present study were to investigate olfactory sensitivity in ASC, and to test the association of sensitivity to autistic traits. We recruited 17 adult males diagnosed with ASC and 17 typical adult male controls and tested their olfactory sensitivity using the Alcohol Sniff Test (AST), a standardised clinical evaluation of olfactory detection. The AST involves varying the distance between subject and stimulus until an odour is barely detected. Participants with ASC also completed the Autism Spectrum Quotient (AQ) as a measure of autism traits. The ASC group detected the odour at a mean distance of 24.1 cm (SD =11.5) from the nose, compared to the control group, who detected it at a significantly shorter mean distance of 14.4 cm (SD =5.9). Detection distance was independent of age and IQ for both groups, but showed a significant positive correlation with autistic traits in the ASC group (r =0.522). This is the first experimental demonstration, as far as the authors are aware, of superior olfactory perception in ASC and showing that greater olfactory sensitivity is correlated with a higher number of autistic traits. This is consistent with results from previous findings showing hypersensitivity in other sensory domains and may help explain anecdotal and questionnaire accounts of heightened olfactory sensitivity in ASC. Results are discussed in terms of possible underlying neurophysiology.
Doppler imaging with dual-detection full-range frequency domain optical coherence tomography
Meemon, Panomsak; Lee, Kye-Sung; Rolland, Jannick P.
2010-01-01
Most of full-range techniques for Frequency Domain Optical Coherence Tomography (FD-OCT) reported to date utilize the phase relation between consecutive axial lines to reconstruct a complex interference signal and hence may exhibit degradation in either mirror image suppression performance or detectable velocity dynamic range or both when monitoring a moving sample such as flow activity. We have previously reported a technique of mirror image removal by simultaneous detection of the quadrature components of a complex spectral interference called a Dual-Detection Frequency Domain OCT (DD-FD-OCT) [Opt. Lett. 35, 1058-1060 (2010)]. The technique enables full range imaging without any loss of acquisition speed and is intrinsically less sensitive to phase errors generated by involuntary movements of the subject. In this paper, we demonstrate the application of the DD-FD-OCT to a phase-resolved Doppler imaging without degradation in either mirror image suppression performance or detectable velocity dynamic range that were observed in other full-range Doppler methods. In order to accommodate for Doppler imaging, we have developed a fiber-based DD-FD-OCT that more efficiently utilizes the source power compared with the previous free-space DD-FD-OCT. In addition, the velocity sensitivity of the phase-resolved DD-FD-OCT was investigated, and the relation between the measured Doppler phase shift and set flow velocity of a flow phantom was verified. Finally, we demonstrate the Doppler imaging using the DD-FD-OCT in a biological sample. PMID:21258488
PFIESTERIA PISCICIDA-INDUCED COGNITIVE EFFECTS: VISUAL SIGNAL DETECTION PERFORMANCE AND REVERSAL.
Humans exposed to Pfiesteria piscicida report cognitive impairment. In a rat model, we showed that exposure to Pfiesteria impaired learning a new task, but not performance of previously-learned behavior. In this study, we characterized the behavioral effects of Pfiesteria in rats...
Molecular identification and detection of Phytophthora ramorum
Peter Bonants; Els Verstappen; Ineke De Vries; Katarzyna Wiejacha; Kelly Ivors
2006-01-01
The genus Phytophthora comprises over 70 described species, however many new species have been reported recently as a result of the discovery of previously undetected species or by the hybridization of known species. Phytophthora ramorum, one of the new Phytophthora species, is considered a high phytosanitary...
Tse, Herman; Tsoi, Hoi-Wah; Teng, Jade L. L.; Chen, Xin-Chun; Liu, Haiying; Zhou, Boping; Zheng, Bo-Jian; Woo, Patrick C. Y.; Lau, Susanna K. P.; Yuen, Kwok-Yung
2011-01-01
Partetravirus is a recently described group of animal parvoviruses which include the human partetravirus, bovine partetravirus and porcine partetravirus (previously known as human parvovirus 4, bovine hokovirus and porcine hokovirus respectively). In this report, we describe the discovery and genomic characterization of partetraviruses in bovine and ovine samples from China. These partetraviruses were detected by PCR in 1.8% of bovine liver samples, 66.7% of ovine liver samples and 71.4% of ovine spleen samples. One of the bovine partetraviruses detected in the present samples is phylogenetically distinct from previously reported bovine partetraviruses and likely represents a novel genotype. The ovine partetravirus is a novel partetravirus and phylogenetically most related to the bovine partetraviruses. The genome organization is conserved amongst these viruses, including the presence of a putative transmembrane protein encoded by an overlapping reading frame in ORF2. Results from the present study provide further support to the classification of partetraviruses as a separate genus in Parvovirinae. PMID:21980506
Mallia, Madhava B; Mittal, Sweety; Sarma, Haladhar D; Banerjee, Sharmila
2016-01-01
Previous studies have clearly demonstrated strong correlation between in vivo distribution and blood clearance of radiopharmaceuticals for the detection of hypoxia. Present study describes an attempt to improve the in vivo distribution of a previously reported 2-nitroimidazole-(99m)Tc(CO)3 complex by tuning its blood clearance pattern through structural modification of the ligand. Herein, a 2-nitroimidazole-dipicolylamine ligand (2-nitroimidazole-DPA) was synthesized in a two-step procedure and radiolabeled with (99m)Tc(CO)3 core. Subsequently, the complex was evaluated in Swiss mice bearing fibrosarcoma tumor. As intended by its design, 2-nitroimidazole-DPA-(99m)Tc(CO)3 complex was more lipophilic than previously reported 2-nitroimidazole-DETA-(99m)Tc(CO)3 complex (DETA-diethylenetriamine) and showed slower blood clearance. Consequently it showed higher tumor uptake than 2-nitroimidazole-DETA-(99m)Tc(CO)3 complex. Significantly, despite structural modifications, other parameters such as the tumor to blood ratio and tumor to muscle ratio of the 2-nitroimidazole-DPA-(99m)Tc(CO)3 complex remained comparable to that of 2-nitroimidazole-DETA-(99m)Tc(CO)3 complex. Present study demonstrates the feasibility of structural modifications for improving in vivo tumor uptake of hypoxia detecting radiopharmaceuticals. This might encourage researchers to improve suboptimal properties of a potential radiopharmaceuticals rather than ignoring it altogether. Copyright © 2015 Elsevier Ltd. All rights reserved.
Image-Subtraction Photometry of Variable Stars in the Globular Clusters NGC 6388 and NGC 6441
NASA Technical Reports Server (NTRS)
Corwin, Michael T.; Sumerel, Andrew N.; Pritzl, Barton J.; Smith, Horace A.; Catelan, M.; Sweigart, Allen V.; Stetson, Peter B.
2006-01-01
We have applied Alard's image subtraction method (ISIS v2.1) to the observations of the globular clusters NGC 6388 and NGC 6441 previously analyzed using standard photometric techniques (DAOPHOT, ALLFRAME). In this reanalysis of observations obtained at CTIO, besides recovering the variables previously detected on the basis of our ground-based images, we have also been able to recover most of the RR Lyrae variables previously detected only in the analysis of Hubble Space Telescope WFPC2 observations of the inner region of NGC 6441. In addition, we report five possible new variables not found in the analysis of the EST observations of NGC 6441. This dramatically illustrates the capabilities of image subtraction techniques applied to ground-based data to recover variables in extremely crowded fields. We have also detected twelve new variables and six possible variables in NGC 6388 not found in our previous groundbased studies. Revised mean periods for RRab stars in NGC 6388 and NGC 6441 are 0.676 day and 0.756 day, respectively. These values are among the largest known for any galactic globular cluster. Additional probable type II Cepheids were identified in NGC 6388, confirming its status as a metal-rich globular cluster rich in Cepheids.
2013-01-01
Background We have recently reported on the changes in plasma free amino acid (PFAA) profiles in lung cancer patients and the efficacy of a PFAA-based, multivariate discrimination index for the early detection of lung cancer. In this study, we aimed to verify the usefulness and robustness of PFAA profiling for detecting lung cancer using new test samples. Methods Plasma samples were collected from 171 lung cancer patients and 3849 controls without apparent cancer. PFAA levels were measured by high-performance liquid chromatography (HPLC)–electrospray ionization (ESI)–mass spectrometry (MS). Results High reproducibility was observed for both the change in the PFAA profiles in the lung cancer patients and the discriminating performance for lung cancer patients compared to previously reported results. Furthermore, multivariate discriminating functions obtained in previous studies clearly distinguished the lung cancer patients from the controls based on the area under the receiver-operator characteristics curve (AUC of ROC = 0.731 ~ 0.806), strongly suggesting the robustness of the methodology for clinical use. Moreover, the results suggested that the combinatorial use of this classifier and tumor markers improves the clinical performance of tumor markers. Conclusions These findings suggest that PFAA profiling, which involves a relatively simple plasma assay and imposes a low physical burden on subjects, has great potential for improving early detection of lung cancer. PMID:23409863
ASLAN, Muhammet Eren; AZKUR, Ahmet Kursat; GAZYAGCI, Serkal
2015-01-01
The aim of the study was to determine the epidemiological data of bovine viral diarrhea virus (BVDV), bovine herpesvirus-1 (BHV-1), bovine herpesvirus-4 (BHV-4), bovine herpesvirus-5 (BHV-5) and Brucella–associated cattle that were previously reported to have abortion and infertility problems in Ankara, Corum, Kirikkale and Yozgat provinces, Turkey. Whole blood and sera samples were obtained from 656 cattle, and antibodies against Brucella spp. were detected in 45 (6.86%) and 41 (6.25%) animals by Rose Bengal plate and serum tube agglutination tests, respectively. The seropositivity rates against BVDV, BHV-1 and BHV-4 were 70.89%, 41.3% and 28.78%, respectively. RT-PCR and PCR were performed to detect RNA and DNA viruses in blood samples, respectively. The BVDV 5′-untranslated region and BHV-1 gB gene detected in this study were phylogenetically analyzed. The BVDV strains analyzed in this study were closely related to those previously reported from Turkey. The nucleotide sequence from the BHV-1 strain detected in this study is the first nucleotide sequence of BHV-1 circulating in this area of Turkey deposited in the GenBank. The presence of Brucella spp. and prevalence of BHV-1, BHV-4 and BVDV in cattle should be further investigated throughout these regions. PMID:26096964
Research and Development of Non-Spectroscopic MEMS-Based Sensor Arrays for Targeted Gas Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loui, A; McCall, S K
2011-10-24
The ability to monitor the integrity of gas volumes is of interest to the stockpile surveillance community. Specifically, the leak detection of noble gases, at relevant concentration ranges and distinguished from other chemical species that may be simultaneously present, is particularly challenging. Aside from the laboratory-based method of gas chromatography-mass spectrometry (GC-MS), where samples may be collected by solid-phase microextraction (SPME) or cryofocusing, the other major approaches for gas-phase detection employ lasers typically operating in the mid-infrared wavelength region. While mass spectrometry can readily detect noble gases - the helium leak detector is an obvious example - laser-based methods suchmore » as infrared (IR) or Raman spectroscopy are completely insensitive to them as their monatomic nature precludes a non-zero dipole moment or changes in polarizability upon excitation. Therefore, noble gases can only be detected by one of two methods: (1) atomic emission spectroscopies which require the generation of plasmas through laser-induced breakdown, electrical arcing, or similar means; (2) non-spectroscopic methods which measure one or more physical properties (e.g., mass, thermal conductivity, density). In this report, we present our progress during Fiscal Year 2011 (FY11) in the research and development of a non-spectroscopic method for noble gas detection. During Fiscal Year 2010 (FY10), we demonstrated via proof-of-concept experiments that the combination of thermal conductivity detection (TCD) and coating-free damped resonance detection (CFDRD) using micro-electromechanical systems (MEMS) could provide selective sensing of these inert species. Since the MEMS-based TCD technology was directly adapted from a brassboard prototype commissioned by a previous chemical sensing project, FY11 efforts focused on advancing the state of the newer CFDRD method. This work, guided by observations previously reported in the open literature, has not only resulted in a substantially measureable increase in selectivity but has also revealed a potential method for mitigating or eliminating thermal drift that does not require a secondary reference sensor. The design of an apparatus to test this drift compensation scheme will be described. We will conclude this report with a discussion of planned efforts in Fiscal Year 2012 (FY12).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, Dean James; Brusseau, Charles A.
2012-01-01
This document is a final report for the polyvinyl toluene (PVT) neutron-gamma (PVT-NG) project, which was sponsored by the Domestic Nuclear Detection Office (DNDO). The PVT-NG sensor uses PVT detectors for both gamma and neutron detection. The sensor exhibits excellent spectral resolution and gain stabilization, which are features that are beneficial for detection of both gamma-ray and neutron sources. In fact, the ability to perform isotope identification based on spectra that were measured by the PVT-NG sensor was demonstrated. As described in a previous report, the neutron sensitivity of the first version of the prototype was about 25% less thanmore » the DNDO requirement of 2.5 cps/ng for bare Cf-252. This document describes design modifications that were expected to improve the neutron sensitivity by about 50% relative to the PVT-NG prototype. However, the project was terminated before execution of the design modifications after portal vendors demonstrated other technologies that enable neutron detection without the use of He-3. Nevertheless, the PVT-NG sensor development demonstrated several performance goals that may be useful in future portal designs.« less
Brian T. Sullivan
2005-01-01
Olfactory sensitivity of the southern pine beetle, Dendroctonus frontalis zimmermann, to compounds isolated from the mid/hindguts of newly emerged conspecific adults was assayed with coupled gas chromatography-electoantennographic detection. All previously reported pheromones for D. frontalis plus eight additional compounds (...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sweany, Melinda
2017-10-01
This is a high-risk effort to leverage knowledge gained from previous work, which focused on detector development leading to better energy resolution and reconstruction errors. This work seeks to enable applications that require precise elemental characterization of materials, such as chemical munitions remediation, offering the potential to close current detection gaps.
Development of a Multi-Sensor Cancer Detection Probe Final Report CRADA No. TC-2026-01
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marion, J.; Hular, R.
This collaboration continued work started under a previous CRADA (TSB-2023-00) to take a detailed concept specification for a multi-sensor needle/probe suitable for breast cancer analysis and produce a prototype system suitable for human FDA trials.
NASA Technical Reports Server (NTRS)
Dhawan, R.; Gunther, M. F.; Claus, R. O.
1991-01-01
Quantitative measurements of the in-plane particle displacement components of ultrasonic surface acoustic wave fields using extrinsic Fizeau fiber interferometric (EFFI) sensors are reported. Wave propagation in materials and the fiber sensor elements are briefly discussed. Calibrated experimental results obtained for simulated acoustic emission events on homogeneous metal test specimens are reported and compared to previous results obtained using piezoelectric transducers.
Thermospheric Neutral Wind Measurement Using the LWA1 and the AFRL Digisonde
2014-09-26
Dr. Stephen White Project Manager, AFRL/RVBXS Chief, Battlespace Environment Division This report is published in the...CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON Dr. Stephen White a. REPORT Unclassified b...emission from meteors has not been previously detected, but this is not the first time its existence has been discussed. Hawkins (1958) conducted a
Priyadarshini, E; Pradhan, N; Panda, P K; Mishra, B K
2015-06-15
The ability of self-functionalized biogenic GNPs towards highly selective colorimetric detection of rare earth element cerium is being reported for the first time. GNPs underwent rapid aggregation on addition of cerium indicated by red shift of SPR peak followed by complete precipitation. Hereby, this concept of co-ordination of cerium ions onto the GNP surface has been utilized for detection of cerium. The remarkable capacity of GNPs to sensitively detect Ce without proves beneficial compared to previous reports of colorimetric sensing. MDL was 15 and 35 ppm by DLS and UV-vis spectroscopy respectively, suggesting DLS to be highly sensitive and a practical alternative in ultrasensitive detection studies. The sensing system showed a good linear fit favouring feasible detection of cerium in range of 2-50 ppm. Similar studies further showed the superior selectivity of biogenic GNPs compared to chemically synthesized counterparts. The sensing system favours on-site analysis as it overcomes need of complex instrumentation, lengthy protocols and surface modification of GNP. Copyright © 2015 Elsevier B.V. All rights reserved.
Tarifa, Anamary; Almirall, José R
2015-05-01
A rapid method for the characterization of both organic and inorganic components of gunshot residues (GSR) is proposed as an alternative tool to facilitate the identification of a suspected shooter. In this study, two fast screening methods were developed and optimized for the detection of organic compounds and inorganic components indicative of GSR presence on the hands of shooters and non-shooters. The proposed methods consist of headspace extraction of volatile organic compounds using a capillary microextraction of volatiles (CMV) device previously reported as a high-efficiency sampler followed by detection by GC-MS. This novel sampling technique has the potential to yield fast results (<2min sampling) and high sensitivity capable of detecting 3ng of diphenylamine (DPA) and 8ng of nitroglycerine (NG). Direct analysis of the headspace of over 50 swabs collected from the hands of suspected shooters (and non-shooters) provides information regarding VOCs present on their hands. In addition, a fast laser induced breakdown spectroscopy (LIBS) screening method for the detection of the inorganic components indicative of the presence of GSR (Sb, Pb and Ba) is described. The sampling method for the inorganics consists of liquid extraction of the target elements from the same cotton swabs (previously analyzed for VOCs) and an additional 30 swab samples followed by spiking 1μL of the extract solution onto a Teflon disk and then analyzed by LIBS. Advantages of LIBS include fast analysis (~12s per sample) and high selectivity and sensitivity, with expected LODs 0.1-18ng for each of the target elements after sampling. The analytical performance of the LIBS method is also compared to previously reported methods (inductively coupled plasma-optical emission spectroscopy). The combination of fast CMV sampling, unambiguous organic compound identification with GC-MS and fast LIBS analysis provides the basis for a new comprehensive screening method for GSR. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
IMANISHI, M.; NEWTON, A. E.; VIEIRA, A. R.; GONZALEZ-AVILES, G.; KENDALL SCOTT, M. E.; MANIKONDA, K.; MAXWELL, T. N.; HALPIN, J. L.; FREEMAN, M. M.; MEDALLA, F.; AYERS, T. L.; DERADO, G.; MAHON, B. E.; MINTZ, E. D.
2016-01-01
SUMMARY Although rare, typhoid fever cases acquired in the United States continue to be reported. Detection and investigation of outbreaks in these domestically acquired cases offer opportunities to identify chronic carriers. We searched surveillance and laboratory databases for domestically acquired typhoid fever cases, used a space–time scan statistic to identify clusters, and classified clusters as outbreaks or non-outbreaks. From 1999 to 2010, domestically acquired cases accounted for 18% of 3373 reported typhoid fever cases; their isolates were less often multidrug-resistant (2% vs. 15%) compared to isolates from travel-associated cases. We identified 28 outbreaks and two possible outbreaks within 45 space–time clusters of ⩾2 domestically acquired cases, including three outbreaks involving ⩾2 molecular subtypes. The approach detected seven of the ten outbreaks published in the literature or reported to CDC. Although this approach did not definitively identify any previously unrecognized outbreaks, it showed the potential to detect outbreaks of typhoid fever that may escape detection by routine analysis of surveillance data. Sixteen outbreaks had been linked to a carrier. Every case of typhoid fever acquired in a non-endemic country warrants thorough investigation. Space–time scan statistics, together with shoe-leather epidemiology and molecular subtyping, may improve outbreak detection. PMID:25427666
Imanishi, M; Newton, A E; Vieira, A R; Gonzalez-Aviles, G; Kendall Scott, M E; Manikonda, K; Maxwell, T N; Halpin, J L; Freeman, M M; Medalla, F; Ayers, T L; Derado, G; Mahon, B E; Mintz, E D
2015-08-01
Although rare, typhoid fever cases acquired in the United States continue to be reported. Detection and investigation of outbreaks in these domestically acquired cases offer opportunities to identify chronic carriers. We searched surveillance and laboratory databases for domestically acquired typhoid fever cases, used a space-time scan statistic to identify clusters, and classified clusters as outbreaks or non-outbreaks. From 1999 to 2010, domestically acquired cases accounted for 18% of 3373 reported typhoid fever cases; their isolates were less often multidrug-resistant (2% vs. 15%) compared to isolates from travel-associated cases. We identified 28 outbreaks and two possible outbreaks within 45 space-time clusters of ⩾2 domestically acquired cases, including three outbreaks involving ⩾2 molecular subtypes. The approach detected seven of the ten outbreaks published in the literature or reported to CDC. Although this approach did not definitively identify any previously unrecognized outbreaks, it showed the potential to detect outbreaks of typhoid fever that may escape detection by routine analysis of surveillance data. Sixteen outbreaks had been linked to a carrier. Every case of typhoid fever acquired in a non-endemic country warrants thorough investigation. Space-time scan statistics, together with shoe-leather epidemiology and molecular subtyping, may improve outbreak detection.
A Rigorous Attempt to Verify Interstellar Glycine
NASA Technical Reports Server (NTRS)
Snyder, L. E.; Lovas, F. J.; Hollis, J. M.; Friedel, D. N.; Jewell, P. R.; Remijan, A.; Ilyushin, V. V.; Alekseev, E. A.; Dyubko, S. F.
2004-01-01
In 2003, Kuan, Charnley, and co-workers reported the detection of interstellar glycine (NH2CH2COOH) based on observations of 27 lines in 19 different spectral bands in one or more of the sources Sgr BP(N-LMH), Orion KL, and W51 e1/e2. They supported their detection report with rotational temperature diagrams for all three sources. In this paper, we present essential criteria which can be used in a straightforward analysis technique to confirm the identity of an interstellar asymmetric rotor such as glycine. We use new laboratory measurements of glycine as a basis for applying this analysis technique, both to our previously unpublished 12 m telescope data and to the previously published SEST data of Nummelin and colleagues. We conclude that key lines necessary for an interstellar glycine identification have not yet been found. We identify several common molecular candidates that should be examined further as more likely carriers of the lines reported as glycine. Finally, we illustrate that rotational temperature diagrams used without the support of correct spectroscopic assignments are not a reliable tool for the identification of interstellar molecules. Subject headings: ISM: abundances - ISM: clouds - ISM: individual (Sagittarius B2[N-
NASA Astrophysics Data System (ADS)
Ghita, Adrian; Matousek, Pavel; Stone, Nick
2018-02-01
Our work focuses on the development of a medical Raman spectroscopy based platform to non-invasively detect and determine in-vivo molecular information deep inside biological tissues by monitoring the chemical composition of breast calcifications. The ultimate goal is to replace a needle biopsy which typically follows the detection of an abnormality in mammographic images. Here we report the non-invasive detection of calcium oxalate monohydrate in tissue through 40 mm of phantom tissues using our recently developed advanced Raman instrument complementing our previous detection of calcium hydroxyapatite through this thickness of tissue. The ability to detect these two key types of calcifications opens avenues for the development of non-invasive in-vivo breast cancer diagnostic tool in the future.
Detections of Propellers in Saturn's Rings using Machine Learning: Preliminary Results
NASA Astrophysics Data System (ADS)
Gordon, Mitchell K.; Showalter, Mark R.; Odess, Jennifer; Del Villar, Ambi; LaMora, Andy; Paik, Jin; Lakhani, Karim; Sergeev, Rinat; Erickson, Kristen; Galica, Carol; Grayzeck, Edwin; Morgan, Thomas; Knopf, William
2015-11-01
We report on the initial analysis of the output of a tool designed to identify persistent, non-axisymmetric features in the rings of Saturn. This project introduces a new paradigm for scientific software development. The preliminary results include what appear to be new detections of propellers in the rings of Saturn.The Planetary Data System (PDS), working with the NASA Tournament Lab (NTL), Crowd Innovation Lab at Harvard University, and the Topcoder community at Appirio, Inc., under the umbrella “Cassini Rings Challenge”, sponsored a set of competitions employing crowd sourcing and machine learning to develop a tool which could be made available to the community at large. The Challenge was tackled by running a series of separate contests to solve individual tasks prior to the major machine learning challenge. Each contest was comprised of a set of requirements, a timeline, one or more prizes, and other incentives, and was posted by Appirio to the Topcoder Community. In the case of the machine learning challenge (a “Marathon Challenge” on the Topcoder platform), members competed against each other by submitting solutions that were scored in real time and posted to a public leader-board by a scoring algorithm developed by Appirio for this contest.The current version of the algorithm was run against ~30,000 of the highest resolution Cassini ISS images. That set included 668 images with a total of 786 features previously identified as propellers in the main rings. The tool identified 81% of those previously identified propellers. In a preliminary, close examination of 130 detections identified by the tool, we determined that of the 130 detections, 11 were previously identified propeller detections, 5 appear to be new detections of known propellers, and 4 appear to be detections of propellers which have not been seen previously. A total of 20 valid detections from 130 candidates implies a relatively high false positive rate which we hope to reduce by further algorithm development. The machine learning aspect of the algorithm means that as our set of verified detections increases so does the pool of “ground-truth” data used to train the algorithm for future use.
The use of ground-penetrating radar in the surveying of overlaid bridge decks : summary report.
DOT National Transportation Integrated Search
1993-01-01
It was shown in a previous study that the presence of delamination in concrete can be detected by the appearance of a distinctive signature in the analog radar reflection profiles recorded when a concrete deck is scanned with ground-penetrating radar...
USDA-ARS?s Scientific Manuscript database
A transparent and functional system for virus classification is essential to allow scientists to correctly identify and report on viruses detected in different hosts or locations without ambiguity. New research into relationships between previously characterized and newly-emerging viruses may requir...
USDA-ARS?s Scientific Manuscript database
A transparent and functional system for virus classification is essential to allow scientists to correctly identify and report on viruses detected in different hosts or locations without ambiguity. New research into relationships between previously characterized and newly-emerging viruses may requir...
USDA-ARS?s Scientific Manuscript database
We have expanded upon a previously reported comparative genomics approach using a read-depth (JaRMs) and a hybrid read-pair, split-read (RAPTR-SV) copy number variation (CNV) detection method that uses read alignments to the cattle reference genome in order to identify species-specific genomic rearr...
USDA-ARS?s Scientific Manuscript database
Lymphoproliferative disease virus (LPDV) is an exogenous oncogenic retrovirus that induces lymphoid tumors in some galliform species of birds. Historically, outbreaks of LPDV have been reported from Europe and Israel. Although the virus has previously never been detected in North America, herein we ...
Spatially-Aware Temporal Anomaly Mapping of Gamma Spectra
NASA Astrophysics Data System (ADS)
Reinhart, Alex; Athey, Alex; Biegalski, Steven
2014-06-01
For security, environmental, and regulatory purposes it is useful to continuously monitor wide areas for unexpected changes in radioactivity. We report on a temporal anomaly detection algorithm which uses mobile detectors to build a spatial map of background spectra, allowing sensitive detection of any anomalies through many days or months of monitoring. We adapt previously-developed anomaly detection methods, which compare spectral shape rather than count rate, to function with limited background data, allowing sensitive detection of small changes in spectral shape from day to day. To demonstrate this technique we collected daily observations over the period of six weeks on a 0.33 square mile research campus and performed source injection simulations.
1983-07-01
tranverse lines, all of which overlapped test areas previously investigated by Technos. The lines were chosen to be representative of cavity areas and...cavities and may be con- sidered as competent rock for this site. It is interesting to note that amplitude perturbations do appear in the zone 95 to 100 ft...tunnels are man-made (regular in shape) and are in reasonably competent rock (not heavily fractured), the tunnel signature wiil be quite evident and
Swift observations of SDSS J141118.31+481257.6 during its first detected outburst
NASA Astrophysics Data System (ADS)
Sandoval, L. E. Rivera; Maccarone, T.
2018-05-01
We report Swift observations of the AM CVn-type system SDSS J141118.31+481257.6 (RA=14:11:18.31, Dec=+48:12:57.6) during its first ever recorded outburst. The system was detected by Tadashi Kojima on 2018-May-20 with a V magnitude of 12.6 +- 0.2 (http://ooruri.kusastro.kyoto-u.ac.jp/mailarchive/vsnet-alert/22176), an increase of 7 mags compared to any previous measurement in the same filter.
Radioisotope studies of the farmville meteorite using γγ-coincidence spectrometry.
Howard, Chris; Ferm, Megan; Cesaratto, John; Daigle, Stephen; Iliadis, Christian
2014-12-01
Radionuclides are cosmogenically produced in meteorites before they fall to the surface of the Earth. Measurement of the radioactive decay of such nuclides provides a wealth of information on the irradiation conditions of the meteorite fragment, the intensity of cosmic rays in the inner solar system, and the magnetic activity of the Sun. We report here on the detection of (26)Al using a sophisticated spectrometer consisting of a HPGe detector and a NaI(Tl) annulus. It is shown that modern γ-ray spectrometers represent an interesting alternative to other detection techniques. Data are obtained for a fragment of the Farmville meteorite and compared to results from Geant4 simulations. In particular, we report on optimizing the detection sensitivity by using suitable coincidence gates for deposited energy and event multiplicity. We measured an (26)Al activity of 48.5±3.5dpm/kg for the Farmville meteorite, in agreement with previously reported values for other H chondrites. Copyright © 2014 Elsevier Ltd. All rights reserved.
Splendore, A; Silva, E O; Alonso, L G; Richieri-Costa, A; Alonso, N; Rosa, A; Carakushanky, G; Cavalcanti, D P; Brunoni, D; Passos-Bueno, M R
2000-10-01
Twenty-eight families with a clinical diagnosis of Treacher Collins syndrome were screened for mutations in the 25 coding exons of TCOF1 and their adjacent splice junctions through SSCP and direct sequencing. Pathogenic mutations were detected in 26 patients, yielding the highest detection rate reported so far for this disease (93%) and bringing the number of known disease-causing mutations from 35 to 51. This is the first report to describe clustering of pathogenic mutations. Thirteen novel polymorphic alterations were characterized, confirming previous reports that TCOF1 has an unusually high rate of single-nucleotide polymorphisms (SNPs) within its coding region. We suggest a possible different mechanism leading to TCS or genetic heterogeneity for this condition, as we identified two families with no apparent pathogenic mutation in the gene. Furthermore, our data confirm the absence of genotype-phenotype correlation and reinforce that the apparent anticipation often observed in TCS families is due to ascertainment bias. Copyright 2000 Wiley-Liss, Inc.
Raman spectrum of bacteriochlorophyll a in the S1 state
NASA Astrophysics Data System (ADS)
Nishizawa, Ei-ichi; Hashimoto, Hideki; Koyama, Yasushi
1991-07-01
The S 1 Raman spectrum of bacteriochlorophyll a is reported for the first time. A one-color experiment using the 351 nm picosecond pulses (duration 50 ps and repetition 1 kHz) for tetrahydrofuran solution detected a transient species, which showed distinct Raman lines at 1567, 1409 and 1320 cm -1 and weak profiles around 1169, 1092, 1051 and 794 cm -1. The other one-color experiment using the 355 nm nanosecond pulses (duration 12 ns and repetition 10 Hz) detected the T 1 species reported previously showing Raman lines at 1578 and 1330 cm -1. Thus, the newly identified transient species, which was pumped and probed within 50 ps, is assigned to S 1.
Oral contraceptives and benign breast disease.
Hislop, T G; Threlfall, W J
1984-08-01
In 1980 a questionnaire was mailed to 726 nurses who had previously entered a study of breast disease in the late 1940s and 1950s; 665 responded. Between the ages of 30 to 49 years, 137 reported detecting their first signs of benign breast disease and 76 reported receiving their first biopsy for these signs. Long-term oral contraceptive usage reduced the risk of developing signs of benign breast disease and the risk of biopsy for these signs. The potential bias due to the effect of prior benign breast disease on the prescribing practices for oral contraceptives was minimized by considering oral contraceptive usage prior to detecting the first signs of benign breast disease.
Aptamer-phage reporters for ultrasensitive lateral flow assays
Adhikari, Meena; Strych, Ulrich; Kim, Jinsu; Goux, Heather; Dhamane, Sagar; Poongavanam, Mohan-Vivekanandan; Hagström, Anna E. V.; Kourentzi, Katerina; Conrad, Jacinta C.; Willson, Richard C.
2015-01-01
We introduce the modification of bacteriophage particles with aptamers for the use as bioanalytical reporters, and demonstrate the use of these particles in ultrasensitive lateral flow assays. M13 phage displaying an in vivo biotinylatable peptide (AviTag) genetically fused to the phage tail protein pIII were used as reporter particle scaffolds, with biotinylated aptamers attached via avidin-biotin linkages, and horseradish peroxidase (HRP) reporter enzymes covalently attached to the pVIII coat protein. These modified viral nanoparticles were used in immunochromatographic sandwich assays for the direct detection of IgE and of the penicillin-binding protein from Staphylococcus aureus (PBP2a). We also developed an additional lateral flow assay for IgE, in which the analyte is sandwiched between immobilized anti-IgE antibodies and aptamer-bearing reporter phage modified with HRP. The limit of detection of this LFA was 0.13 ng/mL IgE, ~100 times lower than those of previously reported IgE assays. PMID:26456715
Aptamer-Phage Reporters for Ultrasensitive Lateral Flow Assays.
Adhikari, Meena; Strych, Ulrich; Kim, Jinsu; Goux, Heather; Dhamane, Sagar; Poongavanam, Mohan-Vivekanandan; Hagström, Anna E V; Kourentzi, Katerina; Conrad, Jacinta C; Willson, Richard C
2015-12-01
We introduce the modification of bacteriophage particles with aptamers for use as bioanalytical reporters, and demonstrate the use of these particles in ultrasensitive lateral flow assays. M13 phage displaying an in vivo biotinylatable peptide (AviTag) genetically fused to the phage tail protein pIII were used as reporter particle scaffolds, with biotinylated aptamers attached via avidin-biotin linkages, and horseradish peroxidase (HRP) reporter enzymes covalently attached to the pVIII coat protein. These modified viral nanoparticles were used in immunochromatographic sandwich assays for the direct detection of IgE and of the penicillin-binding protein from Staphylococcus aureus (PBP2a). We also developed an additional lateral flow assay for IgE, in which the analyte is sandwiched between immobilized anti-IgE antibodies and aptamer-bearing reporter phage modified with HRP. The limit of detection of this LFA was 0.13 ng/mL IgE, ∼100 times lower than those of previously reported IgE assays.
Sconfienza, Luca Maria; Mauri, Giovanni; Muzzupappa, Claudia; Poloni, Alessandro; Bandirali, Michele; Esseridou, Anastassia; Tritella, Stefania; Secchi, Francesco; Di Leo, Giovanni; Sardanelli, Francesco
2015-01-01
AIM: To investigate the prevalence of relevant incidental findings (RIFs) detected during routine abdominal contrast-enhanced computed tomography (CeCT). METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal CeCT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs (if needing additional workup) was noted. RESULTS: One thousand forty abdominal CeCT were performed in 949 patients (528 males, mean age 66 ± 14 years). No significant difference was found between inpatients and outpatients age and sex distribution (P > 0.472). RIFs were found in 195/1040 (18.8%) CeCT [inpatients = 108/470 (23.0%); outpatients = 87/570 (15.2%); P = 0.002]. RIFs were found in 30/440 (6.8%) CeCT with a previous exam and in 165/600 (27.5%) without a previous exam (P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different (P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs. CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal CeCT. Risk of overdiagnosis should be taken into account. PMID:26516432
Detection of target phonemes in spontaneous and read speech.
Mehta, G; Cutler, A
1988-01-01
Although spontaneous speech occurs more frequently in most listeners' experience than read speech, laboratory studies of human speech recognition typically use carefully controlled materials read from a script. The phonological and prosodic characteristics of spontaneous and read speech differ considerably, however, which suggests that laboratory results may not generalise to the recognition of spontaneous speech. In the present study listeners were presented with both spontaneous and read speech materials, and their response time to detect word-initial target phonemes was measured. Responses were, overall, equally fast in each speech mode. However, analysis of effects previously reported in phoneme detection studies revealed significant differences between speech modes. In read speech but not in spontaneous speech, later targets were detected more rapidly than targets preceded by short words. In contrast, in spontaneous speech but not in read speech, targets were detected more rapidly in accented than in unaccented words and in strong than in weak syllables. An explanation for this pattern is offered in terms of characteristic prosodic differences between spontaneous and read speech. The results support claims from previous work that listeners pay great attention to prosodic information in the process of recognising speech.
New Ways to Detect Pediatric Sickle Cell Retinopathy: A Comprehensive Review.
Pahl, Daniel A; Green, Nancy S; Bhatia, Monica; Chen, Royce W S
2017-11-01
Sickle retinopathy reflects disease-related vascular injury of the eye, which can potentially result in visual loss from vitreous hemorrhage or retinal detachment. Here we review sickle retinopathy among children with sickle cell disease, describe the epidemiology, pediatric risk factors, pathophysiology, ocular findings, and treatment. Newer, more sensitive ophthalmological imaging modalities are available for retinal imaging, including ultra-widefield fluorescein angiography, spectral-domain optical coherence tomography, and optical coherence tomography angiography. Optical coherence tomography angiography provides a noninvasive view of retinal vascular layers that could previously not be imaged and can be quantified for comparative or prospective analyses. Ultra-widefield fluorescein angiography provides a more comprehensive view of the peripheral retina than traditional imaging techniques. Screening for retinopathy by standard fundoscopic imaging modalities detects a prevalence of approximately 10%. In contrast, these more sensitive methods allow for more sensitive examination that includes the retina perimeter where sickle retinopathy is often first detectable. Use of these new imaging modalities may detect a higher prevalence of early sickle pathology among children than has previously been reported. Earlier detection may help in better understanding the pathogenesis of sickle retinopathy and guide future screening and treatment paradigms.
High prevalence of Seoul hantavirus in a breeding colony of pet rats.
McELHINNEY, L M; Marston, D A; Pounder, K C; Goharriz, H; Wise, E L; Verner-Carlsson, J; Jennings, D; Johnson, N; Civello, A; Nunez, A; Brooks, T; Breed, A C; Lawes, J; Lundkvist, Å; Featherstone, C A; Fooks, A R
2017-11-01
As part of further investigations into three linked haemorrhagic fever with renal syndrome (HFRS) cases in Wales and England, 21 rats from a breeding colony in Cherwell, and three rats from a household in Cheltenham were screened for hantavirus. Hantavirus RNA was detected in either the lungs and/or kidney of 17/21 (81%) of the Cherwell rats tested, higher than previously detected by blood testing alone (7/21, 33%), and in the kidneys of all three Cheltenham rats. The partial L gene sequences obtained from 10 of the Cherwell rats and the three Cheltenham rats were identical to each other and the previously reported UK Cherwell strain. Seoul hantavirus (SEOV) RNA was detected in the heart, kidney, lung, salivary gland and spleen (but not in the liver) of an individual rat from the Cherwell colony suspected of being the source of SEOV. Serum from 20/20 of the Cherwell rats and two associated HFRS cases had high levels of SEOV-specific antibodies (by virus neutralisation). The high prevalence of SEOV in both sites and the moderately severe disease in the pet rat owners suggest that SEOV in pet rats poses a greater public health risk than previously considered.
Cell of Origin: Exploring an Alternative Contributor to Ovarian Cancer
2015-12-01
of 60 mice). We previously reported that we conducted simple preliminary studies to assess the potential impact of the retroviral infections on...using primers designed to specifically detect exogenous TP53 gene expression. 12. Simple preliminary studies assessing the potential impact of exogenous...Award was ending and we were delinquent with respect to submission of the Closure report and no longer had access to the funds. Since there was such a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffman, D; Dyer, B; Kumaran Nair, C
Purpose: The Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area, linac-mounted ion chamber used to monitor photon fluence during patient treatment. Our previous work evaluated the change of the ion chamber’s response to deviations from static 1×1 cm2 and 10×10 cm2 photon beams and other characteristics integral to use in external beam detection. The aim of this work is to simulate two external beam radiation delivery errors, quantify the detection of simulated errors and evaluate the reduction in patient harm resulting from detection. Methods: Two well documented radiation oncology delivery errors were selected formore » simulation. The first error was recreated by modifying a wedged whole breast treatment, removing the physical wedge and calculating the planned dose with Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI). The second error was recreated by modifying a static-gantry IMRT pharyngeal tonsil plan to be delivered in 3 unmodulated fractions. A radiation oncologist evaluated the dose for simulated errors and predicted morbidity and mortality commiserate with the original reported toxicity, indicating that reported errors were approximately simulated. The ion chamber signal of unmodified treatments was compared to the simulated error signal and evaluated in Pinnacle TPS again with radiation oncologist prediction of simulated patient harm. Results: Previous work established that transmission detector system measurements are stable within 0.5% standard deviation (SD). Errors causing signal change greater than 20 SD (10%) were considered detected. The whole breast and pharyngeal tonsil IMRT simulated error increased signal by 215% and 969%, respectively, indicating error detection after the first fraction and IMRT segment, respectively. Conclusion: The transmission detector system demonstrated utility in detecting clinically significant errors and reducing patient toxicity/harm in simulated external beam delivery. Future work will evaluate detection of other smaller magnitude delivery errors.« less
NASA Astrophysics Data System (ADS)
Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing
2013-08-01
Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.
Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing
2013-01-01
Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring. PMID:23982222
Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing
2013-01-01
Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.
Entropy Beacon: A Hairpin-Free DNA Amplification Strategy for Efficient Detection of Nucleic Acids
2015-01-01
Here, we propose an efficient strategy for enzyme- and hairpin-free nucleic acid detection called an entropy beacon (abbreviated as Ebeacon). Different from previously reported DNA hybridization/displacement-based strategies, Ebeacon is driven forward by increases in the entropy of the system, instead of free energy released from new base-pair formation. Ebeacon shows high sensitivity, with a detection limit of 5 pM target DNA in buffer and 50 pM in cellular homogenate. Ebeacon also benefits from the hairpin-free amplification strategy and zero-background, excellent thermostability from 20 °C to 50 °C, as well as good resistance to complex environments. In particular, based on the huge difference between the breathing rate of a single base pair and two adjacent base pairs, Ebeacon also shows high selectivity toward base mutations, such as substitution, insertion, and deletion and, therefore, is an efficient nucleic acid detection method, comparable to most reported enzyme-free strategies. PMID:26505212
Identification of novel Theileria genotypes from Grant's gazelle
Hooge, Janis; Howe, Laryssa; Ezenwa, Vanessa O.
2015-01-01
Blood samples collected from Grant's gazelles (Nanger granti) in Kenya were screened for hemoparasites using a combination of microscopic and molecular techniques. All 69 blood smears examined by microscopy were positive for hemoparasites. In addition, Theileria/Babesia DNA was detected in all 65 samples screened by PCR for a ~450-base pair fragment of the V4 hypervariable region of the 18S rRNA gene. Sequencing and BLAST analysis of a subset of PCR amplicons revealed widespread co-infection (25/39) and the existence of two distinct Grant's gazelle Theileria subgroups. One group of 11 isolates clustered as a subgroup with previously identified Theileria ovis isolates from small ruminants from Europe, Asia and Africa; another group of 3 isolates clustered with previously identified Theileria spp. isolates from other African antelope. Based on extensive levels of sequence divergence (1.2–2%) from previously reported Theileria species within Kenya and worldwide, the Theileria isolates detected in Grant's gazelles appear to represent at least two novel Theileria genotypes. PMID:25973394
Identification of novel Theileria genotypes from Grant's gazelle.
Hooge, Janis; Howe, Laryssa; Ezenwa, Vanessa O
2015-08-01
Blood samples collected from Grant's gazelles (Nanger granti) in Kenya were screened for hemoparasites using a combination of microscopic and molecular techniques. All 69 blood smears examined by microscopy were positive for hemoparasites. In addition, Theileria/Babesia DNA was detected in all 65 samples screened by PCR for a ~450-base pair fragment of the V4 hypervariable region of the 18S rRNA gene. Sequencing and BLAST analysis of a subset of PCR amplicons revealed widespread co-infection (25/39) and the existence of two distinct Grant's gazelle Theileria subgroups. One group of 11 isolates clustered as a subgroup with previously identified Theileria ovis isolates from small ruminants from Europe, Asia and Africa; another group of 3 isolates clustered with previously identified Theileria spp. isolates from other African antelope. Based on extensive levels of sequence divergence (1.2-2%) from previously reported Theileria species within Kenya and worldwide, the Theileria isolates detected in Grant's gazelles appear to represent at least two novel Theileria genotypes.
Junkuy, Anongphan; Aramrattana, Apinun; Sribanditmongkol, Pongruk
2014-07-01
Three diagnostic methods have dominated drug-abuse research: self-report, urinalysis and hair analysis. Previous studies have compared detection rates for various drugs, but none has focused a three-pronged concordance study on the use of methamphetamine (MA). To determine and compare the rates of MA detection in urine and hair of subjects who reported consuming MA in the form of Yaba. Self-reports of Yaba use, as well as biological specimens for chemical analyses, were collected from paid volunteers participating in a larger project studying risk-taking behavior of young adults in northern Thailand. All subjects in the present study reported using Yaba within 90 days of enrollment. Hair analysis for MA followed a validated protocol that coupled solid phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS). Preliminary urinalysis was by means of REMEDi-HS. Positive urine was confirmed for MA by the SPME/GC-MS protocol. The MA detection rate by hair analysis (34.3%, n = 172) was significantly higher than by urinalysis (19.1%, n = 96) (p < 0.01; McNemar's test). All subjects with MA-positive urine samples reported using Yaba within 30 days of testing, while hair analysis gave positive results for self-reports up to 90 days. Urinalysis showed greater concordance with self-report than hair analysis if testing occurred within seven days of most recent admitted Yaba use. The reverse was true after 14 days. Agreement of laboratory findings with self-reports increased if test results for the two biological matrices were combined. There was no strong agreement between hair analysis and urinalysis for subjects reporting most recent use within 30 days of testing (kappa = 0.131; 95% CI = 0.022-0.240). For the Yaba users in the present study, urinalysis for MA significantly detected more positives than hair analysis if the most recent use reportedly occurred within seven days of testing. Hair analysis yielded better results after an interval of 14 days, with its window of detection extending up to three months. There were no urine positive samples for reported use after 30 days. Combining urinalysis and hair analysis increased the probability of detecting recent MA use. Both urinalysis and hair analysis significantly under-detected MA in the biological samples collected. The combined detection rate was 44.4%. This discrepancy might have resulted from over-reporting of Yaba use due to social/psychological factors and/or insufficient MA consumption causing test results to fall below cutoff levels.
Doebel, Sabine; Rowell, Shaina F.; Koenig, Melissa A.
2016-01-01
The reported research tested the hypothesis that young children detect logical inconsistency in communicative contexts that support the evaluation of speakers’ epistemic reliability. In two experiments (N = 194), 3- to 5-year-olds were presented with two speakers who expressed logically consistent or inconsistent claims. Three-year-olds failed to detect inconsistencies (Experiment 1), 4-year-olds detected inconsistencies when expressed by human speakers but not when read from books, and 5-year-olds detected inconsistencies in both contexts (Experiment 2). In both experiments, children demonstrated skepticism toward testimony from previously inconsistent sources. Executive function and working memory each predicted inconsistency detection. These findings indicate logical inconsistency understanding emerges in early childhood, is supported by social and domain general cognitive skills, and plays a role in adaptive learning from testimony. PMID:27317511
Consciousness of the first order in blindsight
Sahraie, Arash; Hibbard, Paul B.; Trevethan, Ceri T.; Ritchie, Kay L.; Weiskrantz, Lawrence
2010-01-01
At suprathreshold levels, detection and awareness of visual stimuli are typically synonymous in nonclinical populations. But following postgeniculate lesions, some patients may perform above chance in forced-choice detection paradigms, while reporting not to see the visual events presented within their blind field. This phenomenon, termed “blindsight,” is intriguing because it demonstrates a dissociation between detection and perception. It is possible, however, for a blindsight patient to have some “feeling” of the occurrence of an event without seeing per se. This is termed blindsight type II to distinguish it from the type I, defined as discrimination capability in the total absence of any acknowledged awareness. Here we report on a well-studied patient, D.B., whose blindsight capabilities have been previously documented. We have found that D.B. is capable of detecting visual patterns defined by changes in luminance (first-order gratings) and those defined by contrast modulation of textured patterns (textured gratings; second-order stimuli) while being aware of the former but reporting no awareness of the latter. We have systematically investigated the parameters that could lead to visual awareness of the patterns and show that mechanisms underlying the subjective reports of visual awareness rely primarily on low spatial frequency, first-order spatial components of the image. PMID:21078979
NASA Astrophysics Data System (ADS)
Handler, G.; Rybicka, M.; Popowicz, A.; Pigulski, A.; Kuschnig, R.; Zocłońska, E.; Moffat, A. F. J.; Weiss, W. W.; Grant, C. C.; Pablo, H.; Whittaker, G. N.; Ruciński, S. M.; Ramiaramanantsoa, T.; Zwintz, K.; Wade, G. A.
2017-01-01
We report a simultaneous ground- and space-based photometric study of the β Cephei star ν Eridani. Half a year of observations have been obtained by four of the five satellites constituting BRITE-Constellation, supplemented with ground-based photoelectric photometry. We show that carefully combining the two data sets virtually eliminates the aliasing problem that often hampers time series analyses. We detect 40 periodic signals intrinsic to the star in the light curves. Despite a lower detection limit, we do not recover all the pressure and mixed modes previously reported in the literature, but we newly detect six additional gravity modes. This behaviour is a consequence of temporal changes in the pulsation amplitudes that we also detected for some of the p modes. We point out that the dependence of theoretically predicted pulsation amplitude on wavelength is steeper in visual passbands than those observationally measured, to the extent that three dominant pulsation modes of ν Eridani would be incorrectly identified using data in optical filters only. We discuss possible reasons for this discrepancy.
Genetically encoded reporters for hyperpolarized xenon magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Shapiro, Mikhail G.; Ramirez, R. Matthew; Sperling, Lindsay J.; Sun, George; Sun, Jinny; Pines, Alexander; Schaffer, David V.; Bajaj, Vikram S.
2014-07-01
Magnetic resonance imaging (MRI) enables high-resolution non-invasive observation of the anatomy and function of intact organisms. However, previous MRI reporters of key biological processes tied to gene expression have been limited by the inherently low molecular sensitivity of conventional 1H MRI. This limitation could be overcome through the use of hyperpolarized nuclei, such as in the noble gas xenon, but previous reporters acting on such nuclei have been synthetic. Here, we introduce the first genetically encoded reporters for hyperpolarized 129Xe MRI. These expressible reporters are based on gas vesicles (GVs), gas-binding protein nanostructures expressed by certain buoyant microorganisms. We show that GVs are capable of chemical exchange saturation transfer interactions with xenon, which enables chemically amplified GV detection at picomolar concentrations (a 100- to 10,000-fold improvement over comparable constructs for 1H MRI). We demonstrate the use of GVs as heterologously expressed indicators of gene expression and chemically targeted exogenous labels in MRI experiments performed on living cells.
An SSP-PCR method for the rapid detection of disease-associated alleles HLA-A*29 and HLA-B*51.
Amstutz, U; Schaerer, D; Andrey, G; Wirthmueller, U; Largiadèr, C R
2018-05-15
HLA-A*29 and HLA-B*51 are associated with birdshot uveitis and Behçet's disease, respectively, and are used as a diagnostic criterion in patients with suspected disease, requiring their detection in diagnostic laboratories. While commercial tests for individual HLA alleles are available for other disease-associated HLA variants, no similar allele-specific assays are available for HLA-A*29 and -B*51. Here, we report SSP-PCR methods for the detection of HLA-A*29 and -B*51 using a single PCR reaction per allele. The assays were tested in 30 and 32 previously HLA-typed samples, respectively, representing >97% of HLA-A alleles and >93% of HLA-B alleles in a European population. A concordance of 100% was observed with previous typing results, validating these methods for use in a diagnostic or research context. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Astrophysics Data System (ADS)
Wollenweber, S. D.; Tsui, B. M. W.; Lalush, D. S.; Frey, E. C.; Gullberg, G. T.
1998-08-01
The objective of this study was to implement the Hotelling trace (HT) to evaluate the potential increase in defect detection in myocardial SPECT using high-resolution fan-beam (HRF) versus parallel-hole (HRP) collimation and compare results to a previously reported human observer study (G.K. Gregoriou et al., ibid., vol. 42, p. 1267-75, 1995). Projection data from the 3D MCAT torso phantom were simulated including the effects of attenuation, collimator-detector response blurring and scatter. Poisson noise fluctuations were then simulated. The HRP and HRF collimators had the same spatial resolution at 20 cm. The total counts in the projection data sets were proportional to the detection efficiencies of the collimators and on the order of that found in clinical Tc-99m studies. In six left-ventricular defect locations, the HT found for HRF was superior to that for HRP collimation. For HRF collimation, the HT was calculated for reconstructed images using 64/spl times/64, 128/spl times/128 and 192/spl times/192 grid sizes. The results demonstrate substantial improvement in myocardial defect detection when the grid size was increased from 64/spl times/64 to 128/spl times/128 and slight improvement from 128/spl times/128 to 192/spl times/192. Also, the performance of the Hotelling observer in terms of the HT at the different grid sizes correlates at better than 0.95 to that found in human observers in a previously reported observer experiment and ROC study.
Steven, Rory T; Dexter, Alex; Bunch, Josephine
2016-07-15
Recent developments in laser performance, combined with the desire for increases in detected ion intensity and throughput, have led to the adoption of high repetition-rate diode-pumped solid-state (DPSS) lasers in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI). Previous studies have demonstrated a more complex relationship between detected ion intensity, stage raster speed and laser pulse repetition rate than the simple linear relationship between number of pulses and detected ion intensity that might be expected. Here we report, for the first time, the interrelated influence of varying laser energy, repetition rate and stage raster speed on detected ion intensity. Thin films of PC 34:1 lipid standard and murine brain tissue with CHCA are analysed by continuous stage raster MALDI MSI. Contrary to previous reports, the optimum laser repetition rate is found to be dependent on both laser energy and stage raster speed and is found to be as high as 20kHz under some conditions. The effects of different repetition rates and raster speeds are also found to vary for different ion species within MALDI MSI of tissue and so may be significant when either targeting specific molecules or seeking to minimize bias. A clear dependence on time between laser pulses is also observed indicating the underlying mechanisms may be related to on-plate hysteresis-exhibiting processes such as matrix chemical modification. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Terada, Hiroshi; Tokunaga, Alan T.
2017-01-01
We report the multi-epoch detections of water ice in 2.8-4.2 μ {{m}} spectra of two Herbig Ae stars, PDS 144N (A2 IVe) and PDS 453 (F2 Ve), which have an edge-on circumstellar disk. The detected water ice absorption is found to originate from their protoplanetary disks. The spectra show a relatively shallow absorption of water ice of around 3.1 μ {{m}} for both objects. The optical depths of the water ice absorption are ˜0.1 and ˜0.2 for PDS 144N and PDS 453, respectively. Compared to the water ice previously detected in low-mass young stellar objects with an edge-on disk with a similar inclination angle, these optical depths are significantly lower. It suggests that stronger UV radiation from the central stars effectively decreases the water ice abundance around the Herbig Ae stars through photodesorption. The water ice absorption in PDS 453 shows a possible variation of the feature among the six observing epochs. This variation could be due to a change of absorption materials passing through our line of sight to the central star. The overall profile of the water ice absorption in PDS 453 is quite similar to the absorption previously reported in the edge-on disk object d216-0939, and this unique profile may be seen only at a high inclination angle in the range of 76°-80°.
Incidence of facial clefts in Cambridge, United Kingdom.
Bister, Dirk; Set, Patricia; Cash, Charlotte; Coleman, Nicholas; Fanshawe, Thomas
2011-08-01
The aim of this study was to determine the incidence of facial clefting in Cambridge, UK, using multiple resources of ascertainment and to relate the findings to antenatal ultrasound screening (AUS) detection rates. AUS records from an obstetric ultrasound department, post-natal records from the regional craniofacial unit, and autopsy reports of foetuses over 16 weeks' gestational age from a regional pathology department from 1993 to 1997 were retrospectively reviewed. Cross-referencing between the three data sets identified all cases of facial clefts. Of 23,577 live and stillbirths, 30 had facial clefts. AUS detected 17 of these. Sixteen of the 30 had isolated facial clefts. Others had associated anomalies, chromosomal defects, or syndromes. Percentages and confidence intervals were calculated from the above data. Twenty-one resulted in live births, seven terminations, and two foetal deaths. Overall, detection rate by AUS was 65 percent [67 percent isolated cleft lip, 93 per cent cleft lip and palate (CLP), and 22 percent isolated cleft palate], with no false positives. The incidence of facial clefts was 0.127 percent (95 percent confidence interval 0.089-0.182 percent); the incidence for isolated CLP was lower than previously reported: 0.067 percent (0.042-0.110 percent). With one exception, all terminations were in foetuses with multiple anomalies. The figures presented will enable joint CLP clinics to give parents information of termination rates. The study allows pre-pregnancy counselling of families previously affected by clefting about the reliability of AUS detection rates.
Detection of New Dissociative Electron Attachment Channels in NO
NASA Technical Reports Server (NTRS)
Orient, O. J.; Chutjian, A.
1995-01-01
Three dissociative electron attachment channels have been detected and identified in NO via measurement of the O minus (exp 2)P fragment energy. In addition to the known N((exp 2 D(exp 0)) + O minus (exp 2)P channel, two new channels N((exp 1 S(exp 0)) + 0 (2 P) and N(exp 2)P(exp 0) + O(exp 2)P were detected. Cross sections for each of the channels are reported by normalizing the scattering intensities to previously measured total cross sections. The experimental approach uses solenoidal magnetic confinement of the electrons and ions, and trochoidal energy analysis of the low-energy ions.
Compact Highly Sensitive Multi-species Airborne Mid-IR Spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richter, Dirk; Weibring, P.; Walega, J.
2015-02-01
We report on the development and airborne field deployment of a mid-IR laser based spectrometer. The instrument was configured for the simultaneous in-situ detection of formaldehyde (CH2O) and ethane (C2H6). Numerous mechanical, optical, electronic, and software improvements over a previous instrument design resulted in reliable highly sensitive airborne operation with long stability times yielding 90% airborne measurement coverage during the recent air quality study over the Colorado front range, FRAPPÉ 2014. Airborne detection sensitivities of ~ 15 pptv (C2H6) and ~40 pptv (CH2O) were generally obtained for 1 s of averaging for simultaneous detection.
Tomar, Swati; Sethi, Raman; Sundar, Gangadhara; Quah, Thuan Chong; Quah, Boon Long; Lai, Poh San
2017-01-01
Retinoblastoma (RB) is a rare childhood malignant disorder caused by the biallelic inactivation of RB1 gene. Early diagnosis and identification of carriers of heritable RB1 mutations can improve disease outcome and management. In this study, mutational analysis was conducted on fifty-nine matched tumor and peripheral blood samples from 18 bilateral and 41 unilateral unrelated RB cases by a combinatorial approach of Multiplex Ligation-dependent Probe Amplification (MLPA) assay, deletion screening, direct sequencing, copy number gene dosage analysis and methylation assays. Screening of both blood and tumor samples yielded a mutation detection rate of 94.9% (56/59) while only 42.4% (25/59) of mutations were detected if blood samples alone were analyzed. Biallelic mutations were observed in 43/59 (72.9%) of tumors screened. There were 3 cases (5.1%) in which no mutations could be detected and germline mutations were detected in 19.5% (8/41) of unilateral cases. A total of 61 point mutations were identified, of which 10 were novel. There was a high incidence of previously reported recurrent mutations, occurring at 38.98% (23/59) of all cases. Of interest were three cases of mosaic RB1 mutations detected in the blood from patients with unilateral retinoblastoma. Additionally, two germline mutations previously reported to be associated with low-penetrance phenotypes: missense-c.1981C>T and splice variant-c.607+1G>T, were observed in a bilateral and a unilateral proband, respectively. These findings have implications for genetic counselling and risk prediction for the affected families. This is the first published report on the spectrum of mutations in RB patients from Singapore and shows that further improved mutation screening strategies are required in order to provide a definitive molecular diagnosis for every case of RB. Our findings also underscore the importance of genetic testing in supporting individualized disease management plans for patients and asymptomatic family members carrying low-penetrance, germline mosaicism or heritable unilateral mutational phenotypes.
Solar g-modes? Comparison of detected asymptotic g-mode frequencies with solar model predictions
NASA Astrophysics Data System (ADS)
Wood, Suzannah Rebecca; Guzik, Joyce Ann; Mussack, Katie; Bradley, Paul A.
2018-06-01
After many years of searching for solar gravity modes, Fossat et al. (2017) reported detection of the nearly equally spaced high-order g-modes periods using a 15-year time series of GOLF data from the SOHO spacecraft. Here we report progress towards and challenges associated with calculating and comparing g-mode period predictions for several previously published standard solar models using various abundance mixtures and opacities, as well as the predictions for some non-standard models incorporating early mass loss, and compare with the periods reported by Fossat et al (2017). Additionally, we have a side-by-side comparison of results of different stellar pulsation codes for calculating g-mode predictions. These comparisons will allow for testing of nonstandard physics input that affect the core, including an early more massive Sun and dynamic electron screening.
Thomas, Lashun K.; Journey, Celeste A.; Stringfield, Whitney J.; Clark, Jimmy M.; Bradley, Paul M.; Wellborn, John B.; Ratliff, Hagan; Abrahamsen, Thomas A.
2011-01-01
A spatial survey of streams was conducted from February to April 2010 to assess the concentrations of major ions, selected trace elements, semivolatile organic compounds, organochlorine pesticides, and polychlorinated biphenyls associated with the bed sediments of surface waters at Fort Gordon military installation near Augusta, Georgia. This investigation expanded a previous study conducted in May 1998 by the U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, that evaluated the streambed sediment quality of selected surface waters at Fort Gordon. The data presented in this report are intended to help evaluate bed sediment quality in relation to guidelines for the protection of aquatic life, and identify temporal trends in trace elements and semivolatile organic compound concentrations at streambed sites previously sampled. Concentrations of 34 major ions and trace elements and 102 semivolatile organic, organochlorine pesticide, and polychlorinated biphenyl compounds were determined in the fine-grained fraction of bed sediment samples collected from 13 of the original 29 sites in the previous study, and 22 additional sites at Fort Gordon. Three of the sites were considered reference sites as they were presumed to be located away from potential sources of contaminants and were selected to represent surface waters flowing onto the fort, and the remaining 32 nonreference sites were presumed to be located within the contamination area at the fort. Temporal trends in trace elements and semivolatile organic compound concentrations also were evaluated at 13 of the 32 nonreference sites to provide an assessment of the variability in the number of detections and concentrations of constituents in bed sediment associated with potential sources, accumulation, and attenuation processes. Major ion and trace element concentrations in fine-grained bed sediment samples from most nonreference sites exceeded concentrations in samples from reference sites at Fort Gordon. Bed sediments from one of the nonreference sites sampled contained the highest concentrations of copper and lead with elevated levels of zinc and chromium relative to reference sites. The percentage change of major ions, trace elements, and total organic carbon that had been detected at sites previously sampled in May 1998 and current bed sediment sites ranged from -4 to 8 percent with an average percentage change of less than 1 percent. Concentrations of major ions and trace elements in bed sediments exceeded probable effect levels for aquatic life (based on the amphipod Hyalella azteca) established by the U.S. Environmental Protection Agency at 46 and 69 percent of the current and previously sampled locations, respectively. The greatest frequency of exceedances for major ions and trace elements in bed sediments was observed for lead. Concentrations of semivolatile organic compounds, organochlorine pesticides, and polychlorinated biphenyls were detected in bed sediment samples at 94 percent of the sites currently sampled. Detections of these organic compounds were reported with greater frequency in bed sediments at upstream sampling locations, when compared to downstream locations. The greatest number of detections of these compounds was reported for bed sediment samples collected from two creeks above a lake. The percentage change of semivolatile organic compounds detected at previously sampled and current bed sediment sites ranged from -68 to 100 percent with the greatest percentage increase reported for one of the creeks above the lake. Concentrations of semivolatile organic compounds and polychlorinated biphenyls in bed sediments exceeded aquatic life criteria established by the U.S. Environmental Protection Agency at three sites. Contaminant compounds exceeding aquatic life criteria included fluoranthene, phenanthrene, anthracene, benzo(a)anthracene
(abstract) Dynamics of Meteor Trails Deposited in the Equatorial Electrojet
NASA Technical Reports Server (NTRS)
Chapin, Elaine; Kudeki, Erhan
1996-01-01
Previously we reported that the meteor echoes detected at the Jicamarca Radio Observatory exhibit some unusual properties. In summary, the echo durations are very long ..., radio wave scattering is non-specular ..., and the doppler spectra of the scattered signals contain components that are red-shifted ... immediately after the onset of the echoes.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-21
... installation of certain serial number (S/N) starter generators and replacing the starter generator if one with an affected serial number is found. This proposed AD results from reports that starter generators... proposing this AD to detect and replace starter generators with defective armature insulating materials...
Complete Genome Sequence of Porcine Parvovirus 2 Recovered from Swine Sera
Kluge, M.; Franco, A. C.; Giongo, A.; Valdez, F. P.; Saddi, T. M.; Brito, W. M. E. D.; Roehe, P. M.
2016-01-01
A complete genomic sequence of porcine parvovirus 2 (PPV-2) was detected by viral metagenome analysis on swine sera. A phylogenetic analysis of this genome reveals that it is highly similar to previously reported North American PPV-2 genomes. The complete PPV-2 sequence is 5,426 nucleotides long. PMID:26823583
Measurement of soil creep by inclinometer
Robert R. Ziemer
1977-01-01
Abstract - Continued inclinometer measurements at borehole sites installed in 1964 in northern California suggest that previously reported rates of soil creep are excessively high. Upon analysis of 35 access casings located in forested and grassland sites, no consistent direction of soil movement could be detected. In addition, no significant rate of soil creep could...
Haemophilus haemolyticus Isolates Causing Clinical Disease
Wang, Xin; Briere, Elizabeth C.; Katz, Lee S.; Cohn, Amanda C.; Clark, Thomas A.; Messonnier, Nancy E.; Mayer, Leonard W.
2012-01-01
We report seven cases of Haemophilus haemolyticus invasive disease detected in the United States, which were previously misidentified as nontypeable Haemophilus influenzae. All cases had different symptoms and presentations. Our study suggests that a testing scheme that includes reliable PCR assays and standard microbiological methods should be used in order to improve H. haemolyticus identification. PMID:22573587
Haemophilus haemolyticus isolates causing clinical disease.
Anderson, Raydel; Wang, Xin; Briere, Elizabeth C; Katz, Lee S; Cohn, Amanda C; Clark, Thomas A; Messonnier, Nancy E; Mayer, Leonard W
2012-07-01
We report seven cases of Haemophilus haemolyticus invasive disease detected in the United States, which were previously misidentified as nontypeable Haemophilus influenzae. All cases had different symptoms and presentations. Our study suggests that a testing scheme that includes reliable PCR assays and standard microbiological methods should be used in order to improve H. haemolyticus identification.
Triclosan (TCS), a broad-spectrum antimicrobial agent found in many personal care products, has been detected in humans and has been shown to interact with endocrine systems in rats. We previously reported that TCS potentiated the estrogenic effect of ethinyl estradiol (EE) on u...
DOT National Transportation Integrated Search
1980-03-01
This report presents the findings of a workshop on the chemical analysis of human body fluids for drugs of interest in highway safety. A cross-disciplinary panel of experts reviewed the list of drugs of interest developed in a previous workshop and d...
Circumpolar variation in periodicity and synchrony among gypsy moth populations
Derek M. Johnson; Andrew M. Liebhold; Ottar N. Bjornstad; Michael L. Mcmanus; Michael L. Mcmanus
2005-01-01
Previous studies or insect dynamics have detected spatial synchrony in intraspecific population dynamics up to, but not exceeding, 1000 km. Oddly, interspecific synchrony has recently been reported at distances well over 1000 km (at continental and circumpolar scales). While the authors implicated climatic effects as the cause for the apparent largescale interspecific...
NASA Astrophysics Data System (ADS)
Trigo-Rodriguez, Josep M.
2008-10-01
The present outburst experienced by this Centaur (#IAUC 8978) is the brightest detected since September 2004 [for more details see Trigo-Rodriguez et al. (2008) A&A485, pp. 599-606]. In the previously reported work the outburst frequency was established in 7.3 outbursts/year, typically reaching a +13 maximum magnitude or less.
CAMS confirmation of previously reported meteor showers
NASA Astrophysics Data System (ADS)
Jenniskens, P.; Nénon, Q.; Gural, P. S.; Albers, J.; Haberman, B.; Johnson, B.; Holman, D.; Morales, R.; Grigsby, B. J.; Samuels, D.; Johannink, C.
2016-03-01
Leading up to the 2015 IAU General Assembly, the International Astronomical Union's Working List of Meteor Showers included 486 unconfirmed showers, showers that are not certain to exist. If confirmed, each shower would provide a record of past comet or asteroid activity. Now, we report that 41 of these are detected in the Cameras for Allsky Meteor Surveillance (CAMS) video-based meteor shower survey. They manifest as meteoroids arriving at Earth from a similar direction and orbit, after removing the daily radiant drift due to Earth's motion around the Sun. These showers do exist and, therefore, can be moved to the IAU List of Established Meteor Showers. This adds to 31 previously confirmed showers from CAMS data. For each shower, finding charts are presented based on 230,000 meteors observed up to March of 2015, calculated by re-projecting the drift-corrected Sun-centered ecliptic coordinates into more familiar equatorial coordinates. Showers that are not detected, but should have, and duplicate showers that project to the same Sun-centered ecliptic coordinates, are recommended for removal from the Working List.
Jones, B R; Bancroft, H R
1986-06-01
Polyacrylamide gel electrophoresis was used to examine gut, Malpighian tube, fat-body, testes, and ovarioles tissues of the adult cotton boll weevil, Anthonomus grandis Boh. Esterases for which the inheritance has been reported previously by Terranova using whole-body homogenates were detected in dissected tissues and the probable physiological function of each allozyme is suggested. EST-1 occurs most frequently in ovarioles and female fat bodies. EST-2 is most often found in fat bodies and may be important in lipid turnover. No sex difference was observed. EST-3S is found in fat bodies and reproductive tissue, while EST-3F is always located in gut tissues, indicating that EST-3 is not controlled by a single autosomal locus with two codominant alleles as previously reported. EST-4, the most abundant esterase, can be detected in gut tissue at any age and is probably involved in digestion. EST-5 contains four allozymes which appear most frequently in testes and may be important during reproduction.
García-Chequer, A.J.; Méndez-Tenorio, A.; Olguín-Ruiz, G.; Sánchez-Vallejo, C.; Isa, P.; Arias, C.F.; Torres, J.; Hernández-Angeles, A.; Ramírez-Ortiz, M.A.; Lara, C.; Cabrera-Muñoz, M.L.; Sadowinski-Pine, S.; Bravo-Ortiz, J.C.; Ramón-García, G.; Diegopérez-Ramírez, J.; Ramírez-Reyes, G.; Casarrubias-Islas, R.; Ramírez, J.; Orjuela, M.A.; Ponce-Castañeda, M.V.
2016-01-01
Genes are frequently lost or gained in malignant tumors and the analysis of these changes can be informative about the underlying tumor biology. Retinoblastoma is a pediatric intraocular malignancy, and since deletions in chromosome 13 have been described in this tumor, we performed genome wide sequencing with the Illumina platform to test whether recurrent losses could be detected in low coverage data from DNA pools of Rb cases. An in silico reference profile for each pool was created from the human genome sequence GRCh37p5; a chromosome integrity score and a graphics 40 Kb window analysis approach, allowed us to identify with high resolution previously reported non random recurrent losses in all chromosomes of these tumors. We also found a pattern of gains and losses associated to clear and dark cytogenetic bands respectively. We further analyze a pool of medulloblastoma and found a more stable genomic profile and previously reported losses in this tumor. This approach facilitates identification of recurrent deletions from many patients that may be biological relevant for tumor development. PMID:26883451
Visual acuity of the honey bee retina and the limits for feature detection.
Rigosi, Elisa; Wiederman, Steven D; O'Carroll, David C
2017-04-06
Visual abilities of the honey bee have been studied for more than 100 years, recently revealing unexpectedly sophisticated cognitive skills rivalling those of vertebrates. However, the physiological limits of the honey bee eye have been largely unaddressed and only studied in an unnatural, dark state. Using a bright display and intracellular recordings, we here systematically investigated the angular sensitivity across the light adapted eye of honey bee foragers. Angular sensitivity is a measure of photoreceptor receptive field size and thus small values indicate higher visual acuity. Our recordings reveal a fronto-ventral acute zone in which angular sensitivity falls below 1.9°, some 30% smaller than previously reported. By measuring receptor noise and responses to moving dark objects, we also obtained direct measures of the smallest features detectable by the retina. In the frontal eye, single photoreceptors respond to objects as small as 0.6° × 0.6°, with >99% reliability. This indicates that honey bee foragers possess significantly better resolution than previously reported or estimated behaviourally, and commonly assumed in modelling of bee acuity.
A universal TaqMan-based RT-PCR protocol for cost-efficient detection of small noncoding RNA.
Jung, Ulrike; Jiang, Xiaoou; Kaufmann, Stefan H E; Patzel, Volker
2013-12-01
Several methods for the detection of RNA have been developed over time. For small RNA detection, a stem-loop reverse primer-based protocol relying on TaqMan RT-PCR has been described. This protocol requires an individual specific TaqMan probe for each target RNA and, hence, is highly cost-intensive for experiments with small sample sizes or large numbers of different samples. We describe a universal TaqMan-based probe protocol which can be used to detect any target sequence and demonstrate its applicability for the detection of endogenous as well as artificial eukaryotic and bacterial small RNAs. While the specific and the universal probe-based protocol showed the same sensitivity, the absolute sensitivity of detection was found to be more than 100-fold lower for both than previously reported. In subsequent experiments, we found previously unknown limitations intrinsic to the method affecting its feasibility in determination of mature template RISC incorporation as well as in multiplexing. Both protocols were equally specific in discriminating between correct and incorrect small RNA targets or between mature miRNA and its unprocessed RNA precursor, indicating the stem-loop RT-primer, but not the TaqMan probe, triggers target specificity. The presented universal TaqMan-based RT-PCR protocol represents a cost-efficient method for the detection of small RNAs.
NASA Technical Reports Server (NTRS)
Bolton, Eric K.; Sayler, Gary S.; Nivens, David E.; Rochelle, James M.; Ripp, Steven; Simpson, Michael L.
2002-01-01
We report an integrated CMOS microluminometer optimized for the detection of low-level bioluminescence as part of the bioluminescent bioreporter integrated circuit (BBIC). This microluminometer improves on previous devices through careful management of the sub-femtoampere currents, both signal and leakage, that flow in the front-end processing circuitry. In particular, the photodiode is operated with a reverse bias of only a few mV, requiring special attention to the reset circuitry of the current-to-frequency converter (CFC) that forms the front-end circuit. We report a sub-femtoampere leakage current and a minimum detectable signal (MDS) of 0.15 fA (1510 s integration time) using a room temperature 1.47 mm2 CMOS photodiode. This microluminometer can detect luminescence from as few as 5000 fully induced Pseudomonas fluorescens 5RL bacterial cells. c2002 Elsevier Science B.V. All rights reserved.
Effect of Age and Glaucoma on the Detection of Darks and Lights
Zhao, Linxi; Sendek, Caroline; Davoodnia, Vandad; Lashgari, Reza; Dul, Mitchell W.; Zaidi, Qasim; Alonso, Jose-Manuel
2015-01-01
Purpose We have shown previously that normal observers detect dark targets faster and more accurately than light targets, when presented in noisy backgrounds. We investigated how these differences in detection time and accuracy are affected by age and ganglion cell pathology associated with glaucoma. Methods We asked 21 glaucoma patients, 21 age-similar controls, and 5 young control observers to report as fast as possible the number of 1 to 3 light or dark targets. The targets were positioned at random in a binary noise background, within the central 30° of the visual field. Results We replicate previous findings that darks are detected faster and more accurately than lights. We extend these findings by demonstrating that differences in detection of darks and lights are found reliably across different ages and in observers with glaucoma. We show that differences in detection time increase at a rate of approximately 55 msec/dB at early stages of glaucoma and then remain constant at later stages at approximately 800 msec. In normal subjects, differences in detection time increase with age at a rate of approximately 8 msec/y. We also demonstrate that the accuracy to detect lights and darks is significantly correlated with the severity of glaucoma and that the mean detection time is significantly longer for subjects with glaucoma than age-similar controls. Conclusions We conclude that differences in detection of darks and lights can be demonstrated over a wide range of ages, and asymmetries in dark/light detection increase with age and early stages of glaucoma. PMID:26513506
Effect of Age and Glaucoma on the Detection of Darks and Lights.
Zhao, Linxi; Sendek, Caroline; Davoodnia, Vandad; Lashgari, Reza; Dul, Mitchell W; Zaidi, Qasim; Alonso, Jose-Manuel
2015-10-01
We have shown previously that normal observers detect dark targets faster and more accurately than light targets, when presented in noisy backgrounds. We investigated how these differences in detection time and accuracy are affected by age and ganglion cell pathology associated with glaucoma. We asked 21 glaucoma patients, 21 age-similar controls, and 5 young control observers to report as fast as possible the number of 1 to 3 light or dark targets. The targets were positioned at random in a binary noise background, within the central 30° of the visual field. We replicate previous findings that darks are detected faster and more accurately than lights. We extend these findings by demonstrating that differences in detection of darks and lights are found reliably across different ages and in observers with glaucoma. We show that differences in detection time increase at a rate of approximately 55 msec/dB at early stages of glaucoma and then remain constant at later stages at approximately 800 msec. In normal subjects, differences in detection time increase with age at a rate of approximately 8 msec/y. We also demonstrate that the accuracy to detect lights and darks is significantly correlated with the severity of glaucoma and that the mean detection time is significantly longer for subjects with glaucoma than age-similar controls. We conclude that differences in detection of darks and lights can be demonstrated over a wide range of ages, and asymmetries in dark/light detection increase with age and early stages of glaucoma.
Progress Toward Poliomyelitis Eradication - Pakistan, January 2015-September 2016.
Hsu, Christopher H; Mahamud, Abdirahman; Safdar, Rana Muhammad; Ahmed, Jamal; Jorba, Jaume; Sharif, Salmaan; Farag, Noha; Martinez, Maureen; Tangermann, Rudolph H; Ehrhardt, Derek
2016-11-25
Pakistan, Afghanistan, and Nigeria remain the only countries where endemic wild poliovirus type 1 (WPV1) transmission continues. This report describes the activities, challenges, and progress toward polio eradication in Pakistan during January 2015-September 2016 and updates previous reports (1,2). In 2015, a total of 54 WPV1 cases were reported in Pakistan, an 82% decrease from 2014. In 2016, 15 WPV1 cases had been reported as of November 1, representing a 61% decrease compared with the 38 cases reported during the same period in 2015 (Figure 1). Among the 15 WPV1 cases reported in 2016, children aged <36 months accounted for 13 cases; four of those children had received only a single dose of oral poliovirus vaccine (OPV). Seven of the 15 WPV1 cases occurred in the province of Khyber Pakhtunkhwa (KP), five in Sindh, two in the Federally Administered Tribal Areas (FATA), and one in Balochistan (3). During January-September 2016, WPV1 was detected in 9% (36 of 384) of environmental samples collected, compared with 19% (69 of 354) of samples collected during the same period in 2015. Rigorous implementation of the 2015-2016 National Emergency Action Plan (NEAP) (4), coordinated by the National Emergency Operations Center (EOC), has resulted in a substantial decrease in overall WPV1 circulation compared with the previous year. However, detection of WPV1 cases in high-risk areas and the detection of WPV1 in environmental samples from geographic areas where no polio cases are identified highlight the need to continue to improve the quality of supplemental immunization activities (SIAs),* immunization campaigns focused on vaccinating children with OPV outside of routine immunization services, and surveillance for acute flaccid paralysis (AFP). Continuation and refinement of successful program strategies, as outlined in the new 2016-2017 NEAP (5), with particular focus on identifying children missed by vaccination, community-based vaccination, and rapid response to virus identification are needed to stop WPV transmission.
West Nile virus activity--United States, 2006.
2007-06-08
West Nile virus (WNV) is the leading cause of arboviral encephalitis in the United States. Originally discovered in Africa in 1937, WNV was first detected in the western hemisphere in 1999 in New York City. Since then, WNV has caused seasonal epidemics of febrile illness and severe neurologic disease in the United States. This report summarizes provisional WNV surveillance data for 2006 reported to CDC as of April 3, 2007. During 2006, WNV transmission to humans or animals expanded into 52 counties that had not previously reported transmission and recurred in 1,350 counties where transmission had been reported in previous years. In addition, 1,491 cases of WNV neuroinvasive disease (WNND) were reported in the United States during this period, amounting to a 14% increase from 2005 and the largest number reported since 2003. On the basis of extrapolations from past serosurveys, an estimated 41,750 cases of non-neuroinvasive WNV disease occurred in 2006; of these cases, 2,770 were reported. These findings highlight the need for ongoing surveillance, mosquito control, promotion of personal protection from mosquito bites, and research into additional prevention strategies.
Progress Toward Poliomyelitis Eradication - Pakistan, January 2016-September 2017.
Elhamidi, Youness; Mahamud, Abdirahman; Safdar, Muhammad; Al Tamimi, Wasan; Jorba, Jaume; Mbaeyi, Chukwuma; Hsu, Christopher H; Wadood, Zubair; Sharif, Salmaan; Ehrhardt, Derek
2017-11-24
In 1988, the World Health Assembly launched the Global Polio Eradication Initiative. Among the three wild poliovirus serotypes, only wild poliovirus (WPV) type 1 (WPV1) has been detected since 2012. Since 2014, Pakistan, Afghanistan, and Nigeria remain the only countries with continuing endemic WPV1 transmission. This report describes activities conducted and progress made toward the eradication of poliovirus in Pakistan during January 2016-July 2017 and provides an update to previous reports (1,2). In 2016, Pakistan reported 20 WPV1 cases, a 63% decrease compared with 54 cases in 2015 (3). As of September 25, 2017, five WPV1 cases have been reported in 2017, representing a 69% decline compared with 16 cases reported during the same period in 2016 (Figure 1). During January-September 2017, WPV1 was detected in 72 of 468 (15%) environmental samples collected, compared with 36 of 348 (9%) samples collected during the same period in 2016. WPV1 was detected in environmental samples in areas where no polio cases are being reported, which indicates that WPV1 transmission is continuing in some high-risk areas. Interruption of WPV transmission in Pakistan requires maintaining focus on reaching missed children (particularly among mobile populations), continuing community-based vaccination, implementing the 2017-2018 National Emergency Action Plan (4), and improving routine immunization services.
Detection of intestinal obstruction by radionuclide scan: case report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaudhuri, T.K.
1976-11-01
The value of /sup 99m/Technetium-pertechnetate abdomen scan has recently been established in the diagnosis of Meckel's diverticulum, intussusception, and inflamed appendix. The purpose of this paper is to report a case with small intestinal obstruction secondary to fibrous adhesions which resulted from a previous surgery, in whom a /sup 99m/Technetium-pertechnetate abdomen scan showed increased radionuclide concentration in the area of dilated loop of bowel proximal to the site of obstruction.
Ozkul, Aykut; Ergunay, Koray; Koysuren, Aydan; Alkan, Feray; Arsava, Ethem M; Tezcan, Seda; Emekdas, Gurol; Hacioglu, Sabri; Turan, Mahur; Us, Durdal
2013-07-01
West Nile fever is an important zoonotic infection caused by West Nile virus (WNV), a member of the Flaviviridae. Previous serological data from Turkey suggest widespread WNV circulation. This report includes cases of human and equine WNV infections occurring concurrently, and manifesting as central nervous system infections, in two neighboring provinces of Central Anatolia, Turkey. A partial phylogenetic analysis of the causative virus is given for the first time. The cases were reported in February (horses) and March (human). Symptoms of the disease were similar in the two species, characterized by neurological manifestations suggesting meningoencephalitis. Real-time/nested PCRs and commercial immunoassays and a plaque reduction neutralization assay were employed for the detection of viral RNA and specific antibodies, respectively. WNV RNAs were detected in buffy coat (horses) and cerebrospinal fluid (human) samples. Partial nucleotide sequences of the E-gene coding region revealed that the strains are closely related to viruses of lineage 1, clade 1a. Accompanying equine serosurveillance demonstrated WNV-specific antibodies in 31.6% of the samples. This is the first report of acute WNV infections caused by lineage 1 strains from Turkey, in concordance with previous reports from some European and North African countries. Copyright © 2013 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
The coolest DA white dwarfs detected at soft X-ray wavelengths
NASA Technical Reports Server (NTRS)
Kidder, K. M.; Holberg, J. B.; Barstow, M. A.; Tweedy, R. W.; Wesemael, F.
1992-01-01
New soft X-ray/EUV photometric observations of the DA white dwarfs KPD 0631 + 1043 = WD 0631 + 107 and PG 1113 + 413 = WD 1113 + 413 are analyzed. Previously reported soft X-ray detections of three other DAs and the failure to detect a fourth DA in deep Exosat observations are investigated. New ground-based spectra are presented for all of the objects, with IUE Ly-alpha spectra for some. These data are used to constrain the effective temperatures and surface gravities. The improved estimates of these parameters are employed to refer a photospheric He abundance for the hotter objects and to elucidate an effective observational low-temperature threshold for the detection of pure hydrogen DA white dwarfs at soft X-ray wavelengths.
RAMA casein zymography: Time-saving and highly sensitive casein zymography for MMP7 and trypsin.
Yasumitsu, Hidetaro; Ozeki, Yasuhiro; Kanaly, Robert A
2016-11-01
To detect metalloproteinase-7 (MMP7), zymography is conducted using a casein substrate and conventional CBB stain. It has disadvantages because it is time consuming and has low sensitivity. Previously, a sensitive method to detect MMP7 up to 30 pg was reported, however it required special substrates and complicated handlings. RAMA casein zymography described herein is rapid, sensitive, and reproducible. By applying high-sensitivity staining with low substrate conditions, the staining process is completed within 1 h and sensitivity was increased 100-fold. The method can detect 10 pg MMP7 by using commercially available casein without complicated handlings. Moreover, it increases detection sensitivity for trypsin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Klämpfl, Martin K; Philippen, Philipp B; Lobinger, Babett H
2015-01-01
The yips is considered a task-specific movement disorder. Its estimated prevalence, however, is high compared to similar neurological movement disorders, possibly resulting from previous studies' restriction of samples based on skill level, and self-report bias. Alternatively, this high prevalence might be an indication of additional aetiologies, for example the influence of previously played racket sports. We estimated the prevalence of the putting yips across the skill range, using self-reports in one study and a screening test in a second study. We explored if previously played sports matter for the development of the yips. In study 1, yips prevalence (N = 1,306) and golfers' sports biographies (n = 264) were examined via two online surveys, in which golfers indicated if they were yips-affected. In study 2, golfers (N = 186) putted in a standardised putting test while kinematic and performance measures were recorded. Prevalence was estimated via a kinematic threshold. Sports biographies (n = 119) were obtained via an online survey. Prevalence of currently yips-affected golfers was 22.4% in study 1 and 16.7% in study 2. In both studies, more yips-affected than unaffected golfers had experience in playing racket sports. Yips prevalence remained higher than previously estimated prevalence of other movement disorders but decreased when the whole skill range including professionals and novices was considered. Future studies should use the kinematic screening test instead of self-reports to detect the yips and further investigate the influence of previously played racket sports.
Daily rhythmicity of body temperature in the dog.
Refinetti, R; Piccione, G
2003-08-01
Research over the past 50 years has demonstrated the existence of circadian or daily rhythmicity in the body core temperature of a large number of mammalian species. However, previous studies have failed to identify daily rhythmicity of body temperature in dogs. We report here the successful recording of daily rhythms of rectal temperature in female Beagle dogs. The low robustness of the rhythms (41% of maximal robustness) and the small range of excursion (0.5 degrees C) are probably responsible for previous failures in detecting rhythmicity in dogs.
NASA Technical Reports Server (NTRS)
Hall, R. C. (Principal Investigator)
1973-01-01
The author has identified the following significant results. In earlier reports it has been indicated that it is possible to delineate areas of lodgepole pine timber mortality into three degrees of damage from enlarged ERTS-1 color composites; light, medium, and heavy. It can also be confidently reported that it is now possible to detect all major areas of lodgepole pine defoliated by the needle miner. It has also been confirmed, through ground checking and helicopter observation that previous designation of the following features have been consistently accurate: timbered vs non-timbered areas; timber types; damaged vs undamaged areas; lakes, dome shadows which resemble lakes, mountain meadows, pasture and agricultural land, desert; riparian vegetation; and glaciers.
Study of interhemispheric asymmetries in electroencephalographic signals by frequency analysis
NASA Astrophysics Data System (ADS)
Zapata, J. F.; Garzón, J.
2011-01-01
This study provides a new method for the detection of interhemispheric asymmetries in patients with continuous video-electroencephalography (EEG) monitoring at Intensive Care Unit (ICU), using wavelet energy. We obtained the registration of EEG signals in 42 patients with different pathologies, and then we proceeded to perform signal processing using the Matlab program, we compared the abnormalities recorded in the report by the neurophysiologist, the images of each patient and the result of signals analysis with the Discrete Wavelet Transform (DWT). Conclusions: there exists correspondence between the abnormalities found in the processing of the signal with the clinical reports of findings in patients; according to previous conclusion, the methodology used can be a useful tool for diagnosis and early quantitative detection of interhemispheric asymmetries.
Testing the importance of auditory detections in avian point counts
Brewster, J.P.; Simons, T.R.
2009-01-01
Recent advances in the methods used to estimate detection probability during point counts suggest that the detection process is shaped by the types of cues available to observers. For example, models of the detection process based on distance-sampling or time-of-detection methods may yield different results for auditory versus visual cues because of differences in the factors that affect the transmission of these cues from a bird to an observer or differences in an observer's ability to localize cues. Previous studies suggest that auditory detections predominate in forested habitats, but it is not clear how often observers hear birds prior to detecting them visually. We hypothesized that auditory cues might be even more important than previously reported, so we conducted an experiment in a forested habitat in North Carolina that allowed us to better separate auditory and visual detections. Three teams of three observers each performed simultaneous 3-min unlimited-radius point counts at 30 points in a mixed-hardwood forest. One team member could see, but not hear birds, one could hear, but not see, and the third was nonhandicapped. Of the total number of birds detected, 2.9% were detected by deafened observers, 75.1% by blinded observers, and 78.2% by nonhandicapped observers. Detections by blinded and nonhandicapped observers were the same only 54% of the time. Our results suggest that the detection of birds in forest habitats is almost entirely by auditory cues. Because many factors affect the probability that observers will detect auditory cues, the accuracy and precision of avian point count estimates are likely lower than assumed by most field ornithologists. ?? 2009 Association of Field Ornithologists.
Chemical Sensors Based on IR Spectroscopy and Surface-Modified Waveguides
NASA Technical Reports Server (NTRS)
Lopez, Gabriel P.; Niemczyk, Thomas
1999-01-01
Sol-gel processing techniques have been used to apply thin porous films to the surfaces of planar infrared (IR) waveguides to produce widely useful chemical sensors. The thin- film coating serves to diminish the concentration of water and increase the concentration of the analyte in the region probed by the evanescent IR wave. These porous films are composed of silica, and therefore, conventional silica surface modification techniques can be used to give the surface a specific functional character. The sol-gel film was surface-modified to make the film highly hydrophobic. These sensors were shown to be capable of detecting non-polar organic analytes, such as benzonitrile, in aqueous solution with detection limits in the ppb range. Further, these porous sol-gel structures allow the analytes to diffuse into and out of the films rapidly, thus reaching equilibrium in less than ten seconds. These sensors are unique because of the fact that their operation is based on the measurement of an IR absorption spectrum. Thus, these sensors are able to identify the analytes as well as measure concentration with high sensitivity. These developments have been documented in previous reports and publications. Recently, we have also targeted detection of the polar organic molecules acetone and isopropanol in aqueous solution. Polar organics are widely used in industrial and chemical processes, hence it is of interest to monitor their presence in effluents or decontamination process flows. Although large improvements in detection limits were expected with non-polar organic molecules in aqueous solutions using very hydrophobic porous sol-gel films on silicon attenuated total reflectance (Si ATR) waveguides, it was not as clear what the detection enhancements might be for polar organic molecules. This report describes the use of modified sol-gel-coated Si ATR sensors for trace detection and quantitation of small polar organic molecules in aqueous solutions. The detection of both acetone and isopropanol molecules in aqueous solution has been previously reported for chalcogenide fiber optic sensors. The sol-gel film was produced using a mixture of ethyltriethoxysilane and tetraethoxysilane and the surface modification was carried out using trimethylchlorosilane. We have demonstrated that this film concentrates the target polar analytes from aqueous solution in the region probed by the evanescent wave to improve detection limits by as much as a factor of 450.
The Faintest WISE Debris Disks: Enhanced Methods for Detection and Verification
NASA Astrophysics Data System (ADS)
Patel, Rahul I.; Metchev, Stanimir A.; Heinze, Aren; Trollo, Joseph
2017-02-01
In an earlier study, we reported nearly 100 previously unknown dusty debris disks around Hipparcos main-sequence stars within 75 pc by selecting stars with excesses in individual WISE colors. Here, we further scrutinize the Hipparcos 75 pc sample to (1) gain sensitivity to previously undetected, fainter mid-IR excesses and (2) remove spurious excesses contaminated by previously unidentified blended sources. We improve on our previous method by adopting a more accurate measure of the confidence threshold for excess detection and by adding an optimally weighted color average that incorporates all shorter-wavelength WISE photometry, rather than using only individual WISE colors. The latter is equivalent to spectral energy distribution fitting, but only over WISE bandpasses. In addition, we leverage the higher-resolution WISE images available through the unWISE.me image service to identify contaminated WISE excesses based on photocenter offsets among the W3- and W4-band images. Altogether, we identify 19 previously unreported candidate debris disks. Combined with the results from our earlier study, we have found a total of 107 new debris disks around 75 pc Hipparcos main-sequence stars using precisely calibrated WISE photometry. This expands the 75 pc debris disk sample by 22% around Hipparcos main-sequence stars and by 20% overall (including non-main-sequence and non-Hipparcos stars).
Yang, Xiaomeng; Li, Shuya; Zhao, Xingquan; Liu, Liping; Jiang, Yong; Li, Zixiao; Wang, Yilong; Wang, Yongjun
2017-12-04
Atrial fibrillation (AF) is reported to be a less frequent cause of ischemic stroke in China than in Europe and North America, but it is not clear whether this is due to underestimation. Our aim was to define the true frequency of AF-associated stroke, to determine the yield of 6-day Holter ECG to detect AF in Chinese stroke patients, and to elucidate predictors of newly detected AF. Patients with acute ischemic stroke or transient ischemic attack (TIA) were enrolled in a prospective, multicenter cohort study of 6-day Holter monitoring within 7 days after stroke onset at 20 sites in China between 2013 and 2015. Independent predictors of newly-detected AF were determined by multivariate analysis. Among 1511 patients with ischemic stroke and TIA (mean age 63 years, 33.1% women), 305 (20.2%) had either previously known (196, 13.0%) or AF newly-detected by electrocardiography (53, 3.5%) or by 6-day Holter monitoring (56/1262, 4.4%). A history of heart failure (OR = 4.70, 95%CI, 1.64-13.5), advanced age (OR = 1.06, 95%CI, 1.04-1.09), NIHSS at admission (OR = 1.06, 95%CI, 1.02-1.10), blood high density lipoprotein (HDL) (OR = 1.52, 95%CI, 1.09-2.13), together with blood triglycerides (OR = 0.64, 95%CI, 0.45-0.91) were independently associated with newly-detected AF. Contrary to previous reports, AF-associated stroke is frequent (20%) in China if systemically sought. Prolonged noninvasive cardiac rhythm monitoring importantly increases AF detection in patients with recent ischemic stroke and TIA in China. Advanced age, history of heart failure, and higher admission NIHSS and higher level of HDL were independent indicators of newly-detected AF. NCT02156765 (June 5, 2014).
Yilmaz, Huseyin; Altan, Eda; Cizmecigil, Utku Y; Gurel, Aydin; Ozturk, Gulay Yuzbasioglu; Bamac, Ozge Erdogan; Aydin, Ozge; Britton, Paul; Monne, Isabella; Cetinkaya, Burhan; Morgan, Kenton L; Faburay, Bonto; Richt, Juergen A; Turan, Nuri
2016-09-01
The avian coronavirus infectious bronchitis virus (AvCoV-IBV) is recognized as an important global pathogen because new variants are a continuous threat to the poultry industry worldwide. This study investigates the genetic origin and diversity of AvCoV-IBV by analysis of the S1 sequence derived from 49 broiler flocks and 14 layer flocks in different regions of Turkey. AvCoV-IBV RNA was detected in 41 (83.6%) broiler flocks and nine (64.2%) of the layer flocks by TaqMan real-time RT-PCR. In addition, AvCoV-IBV RNA was detected in the tracheas 27/30 (90%), lungs 31/49 (62.2%), caecal tonsils 7/22 (31.8%), and kidneys 4/49 (8.1%) of broiler flocks examined. Pathologic lesions, hemorrhages, and mononuclear infiltrations were predominantly observed in tracheas and to a lesser extent in the lungs and a few in kidneys. A phylogenetic tree based on partial S1 sequences of the detected AvCoV-IBVs (including isolates) revealed that 1) viruses detected in five broiler flocks were similar to the IBV vaccines Ma5, H120, M41; 2) viruses detected in 24 broiler flocks were similar to those previously reported from Turkey and to Israel variant-2 strains; 3) viruses detected in seven layer flocks were different from those found in any of the broiler flocks but similar to viruses previously reported from Iran, India, and China (similar to Israel variant-1 and 4/91 serotypes); and 4) that the AVCoV-IBV, Israeli variant-2 strain, found to be circulating in Turkey appears to be undergoing molecular evolution. In conclusion, genetically different AvCoV-IBV strains, including vaccine-like strains, based on their partial S1 sequence, are circulating in broiler and layer chicken flocks in Turkey and the Israeli variant-2 strain is undergoing evolution.
Aagaard, Lise; Hansen, Ebba Holme
2009-01-01
Background Despite surveillance efforts, unexpected and serious adverse drug reactions (ADRs) repeatedly occur after marketing. The aim of this article is to analyse ADRs reported by available ADR signal detection approaches and to explore which information about new and unexpected ADRs these approaches have detected. Methods We selected three therapeutic cases for the review: antibiotics for systemic use, non-steroidal anti-inflammatory medicines (NSAID) and selective serotonin re-uptake inhibitors (SSRI). These groups are widely used and represent different therapeutic classes of medicines. The ADR studies were identified through literature search in Medline and Embase. The search was conducted in July 2007. For each therapeutic case, we analysed the time of publication, the strengths of the evidence of safety in the different approaches, reported ADRs and whether the studies have produced new information about ADRs compared to the information available at the time of marketing. Results 79 studies were eligible for inclusion in the analysis: 23 antibiotics studies, 35 NSAID studies, 20 SSRI studies. Studies were mainly published from the end of the 1990s and onwards. Although the drugs were launched in different decades, both analytical and observational approaches to ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. The studies primarily dealt with analyses of ADRs of the type A and B and to a lesser extent C and D, cf. Rawlins' classification system. The therapeutic cases provided similar results with regard to detecting information about new ADRs despite different time periods and organs attacked. Approaches ranging higher in the evidence hierarchy provided information about risks of already known or expected ADRs, while information about new and previously unknown ADRs was only detected by case reports, the lowest ranking approach in the evidence hierarchy. Conclusion Although the medicines were launched in different decades, approaches to the ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. Both descriptive and analytical designs were applied. Despite the fact that analytical studies rank higher in the evidence hierarchy, only the lower ranking descriptive case reports/spontaneous reports provided information about new and previously undetected ADRs. This review underscores the importance of systems for spontaneous reporting of ADRs. Therefore, spontaneous reporting should be encouraged further and the information in ADR databases should continuously be subjected to systematic analysis. PMID:19254390
Aagaard, Lise; Hansen, Ebba Holme
2009-03-03
Despite surveillance efforts, unexpected and serious adverse drug reactions (ADRs) repeatedly occur after marketing. The aim of this article is to analyse ADRs reported by available ADR signal detection approaches and to explore which information about new and unexpected ADRs these approaches have detected. We selected three therapeutic cases for the review: antibiotics for systemic use, non-steroidal anti-inflammatory medicines (NSAID) and selective serotonin re-uptake inhibitors (SSRI). These groups are widely used and represent different therapeutic classes of medicines. The ADR studies were identified through literature search in Medline and Embase. The search was conducted in July 2007. For each therapeutic case, we analysed the time of publication, the strengths of the evidence of safety in the different approaches, reported ADRs and whether the studies have produced new information about ADRs compared to the information available at the time of marketing. 79 studies were eligible for inclusion in the analysis: 23 antibiotics studies, 35 NSAID studies, 20 SSRI studies. Studies were mainly published from the end of the 1990s and onwards. Although the drugs were launched in different decades, both analytical and observational approaches to ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. The studies primarily dealt with analyses of ADRs of the type A and B and to a lesser extent C and D, cf. Rawlins' classification system. The therapeutic cases provided similar results with regard to detecting information about new ADRs despite different time periods and organs attacked. Approaches ranging higher in the evidence hierarchy provided information about risks of already known or expected ADRs, while information about new and previously unknown ADRs was only detected by case reports, the lowest ranking approach in the evidence hierarchy. Although the medicines were launched in different decades, approaches to the ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. Both descriptive and analytical designs were applied. Despite the fact that analytical studies rank higher in the evidence hierarchy, only the lower ranking descriptive case reports/spontaneous reports provided information about new and previously undetected ADRs. This review underscores the importance of systems for spontaneous reporting of ADRs. Therefore, spontaneous reporting should be encouraged further and the information in ADR databases should continuously be subjected to systematic analysis.
Li, You-Qiong; Li, Ru; Li, Dong-Zhi
2013-01-01
Hb Constant Spring [Hb CS, α142, Term→Gln, TAA>CAA (α2)] is a nondeletional form of α-thalassemia (α-thal) that is most prevalent in Southern Chinese and Southeast Asian populations. We previously found that Hb CS trait could efficiently be screened using Sebia Capillarys2. In this study, we report that Hb CS heterozygotes combined with β-thal could not be detected by the Sebia Capillarys2 method due to the very small amount of Hb CS.
An X-Ray Atlas of Groups of Galaxies
NASA Technical Reports Server (NTRS)
Mulchaey, John S.; Davis, David S.; Mushotzky, Richard F.; Burnstein, David
2003-01-01
A search was conducted for a hot intragroup medium in 10(exp 9) low-redshift galaxy groups observed with the ROSAT PSPC. Evidence for diffuse, extended X-ray emission is found in at least 61 groups. Approximately one-third of these detections have not been previously reported in the literature. Most of the groups are detected out to less than half of the virial radius with ROSAT. Although some spiral-rich groups do contain an intragroup medium, diffuse emission is restricted to groups that contain at least one early-type galaxy.
Positron-annihilation-induced ion desorption from TiO2(110)
NASA Astrophysics Data System (ADS)
Tachibana, T.; Hirayama, T.; Nagashima, Y.
2014-05-01
We have investigated the positron-stimulated desorption of ions from a TiO2(110) surface. Desorbed O+ ions were detected in coincidence with the emission of annihilation γ rays. The energy dependence of the ion yields shows that the O+ ions were detected at energies much lower than the previously reported threshold for electron impact desorption corresponding to the excitation energy of Ti(3p) core electrons. These results provide evidence that core-hole creation by positron annihilation with electrons in the core levels leads to ion desorption.
Concurrent insulinoma with mosaic Turner syndrome: A case report.
Wang, Shaoyun; Yang, Lijuan; Li, Jie; Mu, Yiming
2015-03-01
Turner syndrome is a chromosomal abnormality in which the majority of patients have a 45XO karyotype, while a small number have a 45XO/47XXX karyotype. Congenital adrenal hyperplasia has been previously reported in patients with Turner syndrome. Although insulinomas are the most common type of functioning pancreatic neuroendocrine tumor and have been reported in patients with multiple endocrine neoplasias, the tumors have not been reported in patients with mosaic Turner syndrome. The present study reports the first case of an insulinoma in a patient with 45XO/47XXX mosaic Turner syndrome. The patient suffered from recurrent hypoglycemia, which was relieved following ingestion of glucose or food. A 5-h glucose tolerance test was performed and the levels of glucose, C-Peptide and insulin were detected. In addition, computed tomography (CT) and ultrasound scanning were performed to evaluate the possibility of an insulinoma. Pathological examination and karyotyping were performed on a surgical specimen and a whole blood sample, respectively. The patient was found to suffer from premature ovarian failure, and a physical examination was consistent with a diagnosis of Turner syndrome. An ultrasound scan demonstrated streak ovaries and the patient was found to have a 45XO/47XXX karyotype. Furthermore, a lesion was detected in the pancreas following CT scanning, which was identified as an insulinoma following surgical removal and histological examination. In conclusion, the present study reports the first case of an insulinoma in a patient with mosaic Turner syndrome. Since mosaic Turner syndrome and insulinoma are rare diseases, an association may exist that has not been previously identified.
Hansen, Nienke L; Kesch, Claudia; Barrett, Tristan; Koo, Brendan; Radtke, Jan P; Bonekamp, David; Schlemmer, Heinz-Peter; Warren, Anne Y; Wieczorek, Kathrin; Hohenfellner, Markus; Kastner, Christof; Hadaschik, Boris
2017-11-01
To evaluate the detection rates of targeted and systematic biopsies in magnetic resonance imaging (MRI) and ultrasound (US) image-fusion transperineal prostate biopsy for patients with previous benign transrectal biopsies in two high-volume centres. A two centre prospective outcome study of 487 patients with previous benign biopsies that underwent transperineal MRI/US fusion-guided targeted and systematic saturation biopsy from 2012 to 2015. Multiparametric MRI (mpMRI) was reported according to Prostate Imaging Reporting and Data System (PI-RADS) Version 1. Detection of Gleason score 7-10 prostate cancer on biopsy was the primary outcome. Positive (PPV) and negative (NPV) predictive values including 95% confidence intervals (95% CIs) were calculated. Detection rates of targeted and systematic biopsies were compared using McNemar's test. The median (interquartile range) PSA level was 9.0 (6.7-13.4) ng/mL. PI-RADS 3-5 mpMRI lesions were reported in 343 (70%) patients and Gleason score 7-10 prostate cancer was detected in 149 (31%). The PPV (95% CI) for detecting Gleason score 7-10 prostate cancer was 0.20 (±0.07) for PI-RADS 3, 0.32 (±0.09) for PI-RADS 4, and 0.70 (±0.08) for PI-RADS 5. The NPV (95% CI) of PI-RADS 1-2 was 0.92 (±0.04) for Gleason score 7-10 and 0.99 (±0.02) for Gleason score ≥4 + 3 cancer. Systematic biopsies alone found 125/138 (91%) Gleason score 7-10 cancers. In patients with suspicious lesions (PI-RADS 4-5) on mpMRI, systematic biopsies would not have detected 12/113 significant prostate cancers (11%), while targeted biopsies alone would have failed to diagnose 10/113 (9%). In equivocal lesions (PI-RADS 3), targeted biopsy alone would not have diagnosed 14/25 (56%) of Gleason score 7-10 cancers, whereas systematic biopsies alone would have missed 1/25 (4%). Combination with PSA density improved the area under the curve of PI-RADS from 0.822 to 0.846. In patients with high probability mpMRI lesions, the highest detection rates of Gleason score 7-10 cancer still required combined targeted and systematic MRI/US image-fusion; however, systematic biopsy alone may be sufficient in patients with equivocal lesions. Repeated prostate biopsies may not be needed at all for patients with a low PSA density and a negative mpMRI read by experienced radiologists. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Huan, L N; Tejani, A M; Egan, G
2014-10-01
An increasing amount of recently published literature has implicated outcome reporting bias (ORB) as a major contributor to skewing data in both randomized controlled trials and systematic reviews; however, little is known about the current methods in place to detect ORB. This study aims to gain insight into the detection and management of ORB by biomedical journals. This was a cross-sectional analysis involving standardized questions via email or telephone with the top 30 biomedical journals (2012) ranked by impact factor. The Cochrane Database of Systematic Reviews was excluded leaving 29 journals in the sample. Of 29 journals, 24 (83%) responded to our initial inquiry of which 14 (58%) answered our questions and 10 (42%) declined participation. Five (36%) of the responding journals indicated they had a specific method to detect ORB, whereas 9 (64%) did not have a specific method in place. The prevalence of ORB in the review process seemed to differ with 4 (29%) journals indicating ORB was found commonly, whereas 7 (50%) indicated ORB was uncommon or never detected by their journal previously. The majority (n = 10/14, 72%) of journals were unwilling to report or make discrepancies found in manuscripts available to the public. Although the minority, there were some journals (n = 4/14, 29%) which described thorough methods to detect ORB. Many journals seemed to lack a method with which to detect ORB and its estimated prevalence was much lower than that reported in literature suggesting inadequate detection. There exists a potential for overestimation of treatment effects of interventions and unclear risks. Fortunately, there are journals within this sample which appear to utilize comprehensive methods for detection of ORB, but overall, the data suggest improvements at the biomedical journal level for detecting and minimizing the effect of this bias are needed. © 2014 John Wiley & Sons Ltd.
Endosymbiont Dominated Bacterial Communities in a Dwarf Spider
Vanthournout, Bram; Hendrickx, Frederik
2015-01-01
The microbial community of spiders is little known, with previous studies focussing primarily on the medical importance of spiders as vectors of pathogenic bacteria and on the screening of known cytoplasmic endosymbiont bacteria. These screening studies have been performed by means of specific primers that only amplify a selective set of endosymbionts, hampering the detection of unreported species in spiders. In order to have a more complete overview of the bacterial species that can be present in spiders, we applied a combination of a cloning assay, DGGE profiling and high-throughput sequencing on multiple individuals of the dwarf spider Oedothorax gibbosus. This revealed a co-infection of at least three known (Wolbachia, Rickettsia and Cardinium) and the detection of a previously unreported endosymbiont bacterium (Rhabdochlamydia) in spiders. 16S rRNA gene sequences of Rhabdochlamydia matched closely with those of Candidatus R. porcellionis, which is currently only reported as a pathogen from a woodlouse and with Candidatus R. crassificans reported from a cockroach. Remarkably, this bacterium appears to present in very high proportions in one of the two populations only, with all investigated females being infected. We also recovered Acinetobacter in high abundance in one individual. In total, more than 99% of approximately 4.5M high-throughput sequencing reads were restricted to these five bacterial species. In contrast to previously reported screening studies of terrestrial arthropods, our results suggest that the bacterial communities in this spider species are dominated by, or even restricted to endosymbiont bacteria. Given the high prevalence of endosymbiont species in spiders, this bacterial community pattern could be widespread in the Araneae order. PMID:25706947
Fukuda, Koji; Takahashi, Kazuo; Iwata, Yasuhide; Mori, Norio; Gonda, Kenji; Ogawa, Tsuguhiro; Osonoe, Kouichi; Sato, Minako; Ogata, Shin-ichi; Horimoto, Taisuke; Sawada, Takashi; Tashiro, Masato; Yamaguchi, Kazunari; Niwa, Shin-ichi; Shigeta, Shiro
2001-01-01
The involvement of Borna disease virus (BDV) in psychiatric diseases in humans remains controversial. T-cell memory response and seroprevalence of BDV in patients with psychiatric disorders and blood donors in Japan were evaluated collectively by Western blot (WB) analysis with inhibition test, electrochemiluminescence immunoassay, immunofluorescence assay, and T-cell proliferative response as well as detection of BDV p24 RNA in peripheral blood mononuclear cells (PBMCs). Positive proliferative responses to both BDV p40 and p24 proteins were detected in 9% of patients with mood disorders (4 of 45), 4% of schizophrenic patients (2 of 45), and 2% of blood donors (1 of 45). By WB analysis, the antibody to BDV p40 was detected only in 2% of patients with mood disorders (1 of 45). The BDV p24 antibody was detected in 2% of patients with mood disorders (1 of 45) and 9% of schizophrenic patients. (4 of 45) No plasma reacted with both BDV proteins. The finding of a lower seroprevalence than previously reported suggests the presence of false-positive cases in the previous report. BDV RNA was detected only in 2% of patients with mood disorders (1 of 45). In these three serological assays, T-cell responses, and PCR analysis, there was no significant difference in the prevalence among the three groups. However, we found three psychiatric patients who were positive for both BDV antibodies and T-cell proliferative responses and one patient who was positive for BDV RNA in PBMCs. These findings suggest the usefulness of the proliferative T-cell response and that certain individuals are infected with BDV or a BDV-related virus. PMID:11158085
Burton, Casey; Shi, Honglan; Ma, Yinfa
2013-11-19
Recent preliminary studies have implicated urinary pteridines as candidate biomarkers in a growing number of malignancies including breast cancer. While the developments of capillary electrophoresis-laser induced fluorescence (CE-LIF), high performance liquid chromatography (HPLC), and liquid chromatography-mass spectroscopy (LC-MS) pteridine urinalyses among others have helped to enable these findings, limitations including poor pteridine specificity, asynchronous or nonexistent renal dilution normalization, and a lack of information regarding adduct formation in mass spectrometry techniques utilizing electrospray ionization (ESI) have prevented application of these techniques to a larger clinical setting. In this study, a simple, rapid, specific, and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and optimized for simultaneous detection of six pteridines previously implicated in breast cancer and creatinine as a renal dilution factor in urine. In addition, this study reports cationic adduct formation of urinary pteridines under ESI-positive ionization for the first time. This newly developed technique separates and detects the following six urinary pteridines: 6-biopterin, 6-hydroxymethylpterin, d-neopterin, pterin, isoxanthopterin, and xanthopterin, as well as creatinine. The method detection limit for the pteridines is between 0.025 and 0.5 μg/L, and for creatinine, it is 0.15 μg/L. The method was also validated by spiked recoveries (81-105%), reproducibility (RSD: 1-6%), and application to 25 real urine samples from breast cancer positive and negative samples through a double-blind study. The proposed technique was finally compared directly with a previously reported CE-LIF technique, concluding that additional or alternative renal dilution factors are needed for proper investigation of urinary pteridines as breast cancer biomarkers.
do Carmo Teixeira, Diva; Luc Danet, Jean; Eveillard, Sandrine; Cristina Martins, Elaine; de Jesus Junior, Waldir Cintra; Takao Yamamoto, Pedro; Aparecido Lopes, Silvio; Beozzo Bassanezi, Renato; Juliano Ayres, Antonio; Saillard, Colette; Bové, Joseph Marie
2005-06-01
Symptoms of huanglongbing (HLB), one of the most serious diseases of citrus in Asia and Africa, have been noticed in March 2004 in the Araraquara region of São Paulo State, Brazil. HLB has not been reported previously from America. The causal HLB bacteria, Candidatus Liberibacter africanus in Africa and Candidatus Liberibacter asiaticus in Asia, can be detected in symptomatic citrus leaves by PCR amplification of their 16S rDNA with previously described primers. When this technique was applied to 43 symptomatic leaf samples from the Araraquara region, all PCR reactions were negative. This suggested that a new pathogen, not detected by the above primers, could be involved in HLB in the State of São Paulo. Indeed, by using universal primers for amplification of bacterial 16S rDNA, a new liberibacter species, Candidatus Liberibacter americanus, has recently been identified. Specific primers for PCR amplification of the 16S rDNA of Ca. L. americanus have been selected. Using these primers, the new liberibacter could be detected in 214 symptomatic leaf samples tested. The leaves of two additional samples were infected with Candidatus Liberibacter asiaticus, and two further samples contained both Ca. L. americanus and Ca. L. asiaticus. The samples came from 47 farms in 35 municipalities. The psyllid vector of Ca. L. asiaticus, Diaphorina citri, is established in South, Central, and North America (Florida and Texas). Ca. L. americanus could be detected by PCR in several batches of D. citri psyllids collected on symptomatic sweet orange trees infected with Ca. L. americanus, strongly suggesting that D. citri is the vector of Ca. L. americanus. The results reported here confirm the presence of HLB in the State of São Paulo. Ca. L. americanus is the most widely distributed pathogen.
Fermi-LAT Gamma-Ray Detections of Classical Novae V1369 Centauri 2013 and V5668 Sagittarii 2015
NASA Astrophysics Data System (ADS)
Cheung, C. C.; Jean, P.; Shore, S. N.; Stawarz, Ł.; Corbet, R. H. D.; Knödlseder, J.; Starrfield, S.; Wood, D. L.; Desiante, R.; Longo, F.; Pivato, G.; Wood, K. S.
2016-08-01
We report the Fermi Large Area Telescope (LAT) detections of high-energy (>100 MeV) γ-ray emission from two recent optically bright classical novae, V1369 Centauri 2013 and V5668 Sagittarii 2015. At early times, Fermi target-of-opportunity observations prompted by their optical discoveries provided enhanced LAT exposure that enabled the detections of γ-ray onsets beginning ˜2 days after their first optical peaks. Significant γ-ray emission was found extending to 39-55 days after their initial LAT detections, with systematically fainter and longer-duration emission compared to previous γ-ray-detected classical novae. These novae were distinguished by multiple bright optical peaks that encompassed the time spans of the observed γ-rays. The γ-ray light curves and spectra of the two novae are presented along with representative hadronic and leptonic models, and comparisons with other novae detected by the LAT are discussed.
Variation in GIGYF2 is not associated with Parkinson disease.
Nichols, W C; Kissell, D K; Pankratz, N; Pauciulo, M W; Elsaesser, V E; Clark, K A; Halter, C A; Rudolph, A; Wojcieszek, J; Pfeiffer, R F; Foroud, T
2009-06-02
A recent study reported that mutations in a gene on chromosome 2q36-37, GIGYF2, result in Parkinson disease (PD). We have previously reported linkage to this chromosomal region in a sample of multiplex PD families, with the strongest evidence of linkage obtained using the subset of the sample having the strongest family history of disease and meeting the strictest diagnostic criteria. We have tested whether mutations in GIGYF2 may account for the previously observed linkage finding. We sequenced the GIGYF2 coding region in 96 unrelated patients with PD used in our original study that contributed to the chromosome 2q36-37 linkage signal. Subsequently, we genotyped the entire sample of 566 multiplex PD kindreds as well as 1,447 controls to test whether variants in GIGYF2 are causative or increase susceptibility for PD. We detected three novel variants as well as one of the previously reported seven variants in a total of five multiple PD families; however, there was no consistent evidence that these variants segregated with PD in these families. We also did not find a significant increase in risk for PD among those inheriting variants in GIGYF2 (p = 0.28). We believe that variation in a gene other than GIGYF2 accounts for the previously reported linkage finding on chromosome 2q36-37.
Elman, Noel M; Ben-Yoav, Hadar; Sternheim, Marek; Rosen, Rachel; Krylov, Slava; Shacham-Diamand, Yosi
2008-06-15
A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-d-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection.
Bowden, Vanessa K; Loft, Shayne
2016-06-01
In 2 experiments we examined the impact of memory for prior events on conflict detection in simulated air traffic control under conditions where individuals proactively controlled aircraft and completed concurrent tasks. Individuals were faster to detect conflicts that had repeatedly been presented during training (positive transfer). Bayesian statistics indicated strong evidence for the null hypothesis that conflict detection was not impaired for events that resembled an aircraft pair that had repeatedly come close to conflicting during training. This is likely because aircraft altitude (the feature manipulated between training and test) was attended to by participants when proactively controlling aircraft. In contrast, a minor change to the relative position of a repeated nonconflicting aircraft pair moderately impaired conflict detection (negative transfer). There was strong evidence for the null hypothesis that positive transfer was not impacted by dividing participant attention, which suggests that part of the information retrieved regarding prior aircraft events was perceptual (the new aircraft pair "looked" like a conflict based on familiarity). These findings extend the effects previously reported by Loft, Humphreys, and Neal (2004), answering the recent strong and unanimous calls across the psychological science discipline to formally establish the robustness and generality of previously published effects. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Klasson, B; Convery, P; Raschke, S
1998-04-01
Previous publications have reported on the flexibility of ankle-foot orthoses (AFO) only in the same plane as the applied load. This paper reports on a test apparatus developed to detect the flexibility of an AFO in 5 degrees of freedom when subjected to a plantar/dorsiflexion moment, a medial/lateral moment or a torque. A moment applied to an AFO in one plane induces angulation and translation in all planes.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
... fuel transfer system. We are issuing this AD to detect and correct damage to certain fuel booster pumps... problem with the fuel transfer system. The results of the subsequent investigation revealed damage on the... was prompted by a report of an in-flight problem with the fuel transfer system. We are issuing this AD...
PHENYLKETONURIA, DETECTION IN THE NEWBORN INFANT AS A ROUTINE HOSPITAL PROCEDURE.
ERIC Educational Resources Information Center
GUTHRIE, ROBERT; WHITNEY, STEWART
A FIELD TRIAL OF AN INHIBITION ASSAY METHOD FOR SCREENING FOR PHENYLKETONURIA (PKU) TESTED MORE THAN 400,000 NEWBORN INFANTS PRIOR TO DISCHARGE FROM THE HOSPTIAL. IN ALL, 39 CASES WERE FOUND, A HIGHER INCIDENCE THAN HAD PREVIOUSLY BEEN EXPECTED. THE PRACTICALITY OF THE INHIBITION ASSAY METHOD WAS ALSO DEMONSTRATED. THE REPORT DETAILS THE TRIAL'S…
Complete Genome Sequence of Porcine Parvovirus 2 Recovered from Swine Sera.
Campos, F S; Kluge, M; Franco, A C; Giongo, A; Valdez, F P; Saddi, T M; Brito, W M E D; Roehe, P M
2016-01-28
A complete genomic sequence of porcine parvovirus 2 (PPV-2) was detected by viral metagenome analysis on swine sera. A phylogenetic analysis of this genome reveals that it is highly similar to previously reported North American PPV-2 genomes. The complete PPV-2 sequence is 5,426 nucleotides long. Copyright © 2016 Campos et al.
Deborah D. Iwanowicz; William B. Schill; Deanna H. Olson; Michael J. Adams; Christine Densmore; R. Scott Cornman; Cynthia Adams; Jr. Figiel; Chauncey W. Anderson; Andrew R. Blaustein; Tara Chestnut
2017-01-01
We report on the results of surveillance for the salamander chytrid fungus, Batrachochytrium salamandrivorans (Bsal). Two samples from archived DNA used in a previous chytrid study in Oregon were Bsal-positive, alerting us to the first potential finding of this pathogen in North America, infecting American...
Persistence of invading gypsy moth populations in the United States
Stefanie L. Whitmire; Patrick C. Tobin
2006-01-01
Abstract Exotic invasive species are a mounting threat to native biodiversity, and their effects are gaining more public attention as each new species is detected. Equally important are the dynamics of exotic invasives that are previously well established. While the literature reports many examples of the ability of a newly arrived exotic invader to persist prior to...
ERIC Educational Resources Information Center
Iwanami, Akira; Okajima, Yuka; Ota, Haruhisa; Tani, Masayuki; Yamada, Takashi; Hashimoro, Ryuichiro; Kanai, Chieko; Watanabe, Hiromi; Yamasue, Hidenori; Kawakubo, Yuki; Kato, Nobumasa
2011-01-01
Dysfunction of the prefrontal cortex has been previously reported in individuals with Asperger's disorder. In the present study, we used multi-channel near-infrared spectroscopy (NIRS) to detect changes in the oxygenated hemoglobin concentration ([oxy-Hb]) during two verbal fluency tasks. The subjects were 20 individuals with Asperger's disorder…
Searching for the 3.5 keV Line in the Stacked Suzaku Observations of Galaxy Clusters
NASA Technical Reports Server (NTRS)
Bulbul, Esra; Markevitch, Maxim; Foster, Adam; Miller, Eric; Bautz, Mark; Lowenstein, Mike; Randall, Scott W.; Smith, Randall K.
2016-01-01
We perform a detailed study of the stacked Suzaku observations of 47 galaxy clusters, spanning a redshift range of 0.01-0.45, to search for the unidentified 3.5 keV line. This sample provides an independent test for the previously detected line. We detect a 2sigma-significant spectral feature at 3.5 keV in the spectrum of the full sample. When the sample is divided into two subsamples (cool-core and non-cool core clusters), the cool-core subsample shows no statistically significant positive residuals at the line energy. A very weak (approx. 2sigma confidence) spectral feature at 3.5 keV is permitted by the data from the non-cool-core clusters sample. The upper limit on a neutrino decay mixing angle of sin(sup 2)(2theta) = 6.1 x 10(exp -11) from the full Suzaku sample is consistent with the previous detections in the stacked XMM-Newton sample of galaxy clusters (which had a higher statistical sensitivity to faint lines), M31, and Galactic center, at a 90% confidence level. However, the constraint from the present sample, which does not include the Perseus cluster, is in tension with previously reported line flux observed in the core of the Perseus cluster with XMM-Newton and Suzaku.
The magnetic fields of hot subdwarf stars
NASA Astrophysics Data System (ADS)
Landstreet, J. D.; Bagnulo, S.; Fossati, L.; Jordan, S.; O'Toole, S. J.
2012-05-01
Context. Detection of magnetic fields has been reported in several sdO and sdB stars. Recent literature has cast doubts on the reliability of most of these detections. The situation concerning the occurrence and frequency of magnetic fields in hot subdwarfs is at best confused. Aims: We revisit data previously published in the literature, and we present new observations to clarify the question of how common magnetic fields are in subdwarf stars. Methods: We consider a sample of about 40 hot subdwarf stars. About 30 of them have been observed with the FORS1 and FORS2 instruments of the ESO VLT. Results have been published for only about half of the hot subdwarfs observed with FORS. Here we present new FORS1 field measurements for 17 stars, 14 of which have never been observed for magnetic fields before. We also critically review the measurements already published in the literature, and in particular we try to explain why previous papers based on the same FORS1 data have reported contradictory results. Results: All new and re-reduced measurements obtained with FORS1 are shown to be consistent with non-detection of magnetic fields. We explain previous spurious field detections from data obtained with FORS1 as due to a non-optimal method of wavelength calibration. Field detections in other surveys are found to be uncertain or doubtful, and certainly in need of confirmation. Conclusions: There is presently no strong evidence for the occurrence of a magnetic field in any sdB or sdO star, with typical longitudinal field uncertainties of the order of 2-400 G. It appears that globally simple fields of more than about 1 or 2 kG in strength occur in at most a few percent of hot subdwarfs. Further high-precision surveys, both with high-resolution spectropolarimeters and with instruments similar to FORS1 on large telescopes, would be very valuable. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere, Chile under observing programmes 072.D-0290 and 075.D-0352, or obtained from the ESO/ST-ECF Science Archive Facility.
A rapid detection method for paralytic shellfish poisoning toxins by cell bioassay.
Okumura, Masanao; Tsuzuki, Hideaki; Tomita, Ban-Ichi
2005-07-01
We report here a rapid detection method for paralytic shellfish poisoning (PSP) toxins using a cultured neuroblastoma cell line, modified from the bioassay system previously established by Manger et al. [Manger, R.L., Leja, L.S., Lee, S.Y., Hungerford, J.M., Kirkpatrick, M.A., Yasumoto, T., Wekell, M.M., 2003. Detection of paralytic shellfish poison by rapid cell bioassay: antagonism of voltage-gated sodium channel active toxins in vitro. J. AOAC Int. 86 (3), 540-543]. In the present study, we made two major modifications to the previous method. The first is the use of maitotoxin, a marine toxin of ciguatera fish poisoning, which enables the incubation period to be reduced to 6 h when applied to the microplate 15 min prior to the end of the incubation. The second is the use of WST-8, a dehydrogenase detecting water-soluble tetrazolium salt for determining the target cell viability, which permits the omission of a washing step and simplifies the counting process. In addition, we attempted to reduce the required materials as much as possible. Thus, our modified method should be useful for screening the PSP-toxins from shellfish.
DETECTION OF ELEMENTS AT ALL THREE r-PROCESS PEAKS IN THE METAL-POOR STAR HD 160617
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roederer, Ian U.; Lawler, James E., E-mail: iur@obs.carnegiescience.edu, E-mail: jelawler@wisc.edu
2012-05-01
We report the first detection of elements at all three r-process peaks in the metal-poor halo star HD 160617. These elements include arsenic and selenium, which have not been detected previously in halo stars, and the elements tellurium, osmium, iridium, and platinum, which have been detected previously. Absorption lines of these elements are found in archive observations made with the Space Telescope Imaging Spectrograph on board the Hubble Space Telescope. We present up-to-date absolute atomic transition probabilities and complete line component patterns for these elements. Additional archival spectra of this star from several ground-based instruments allow us to derive abundancesmore » or upper limits of 45 elements in HD 160617, including 27 elements produced by neutron-capture reactions. The average abundances of the elements at the three r-process peaks are similar to the predicted solar system r-process residuals when scaled to the abundances in the rare earth element domain. This result for arsenic and selenium may be surprising in light of predictions that the production of the lightest r-process elements generally should be decoupled from the heavier r-process elements.« less
Bujons, J; Ladona, M G; Messeguer, A; Morató, A; Ampurdanés, C
2001-08-01
The Toxic Oil Syndrome was a massive food-borne intoxication that occurred in Spain in 1981. Epidemiological studies point to 3-(phenylamino)propane-1,2-diol (PAP) derivatives as the putative toxic agents. We report further identification of metabolites cleared in urine of A/J and C57BL/6 mice in which (R)- and (S)-3-(phenylamino)propane-1,2-diol were administered intraperitoneally. This investigation is an extension of previous studies carried out with the racemic compound [Ladona, M. G., Bujons, J., Messeguer, A., Ampurdanés, C., Morató, A., and Corbella, J. (1999) Chem. Res. Toxicol. 12, 1127-1137]. Both PAP enantiomers were extensively metabolized, and several metabolites were eliminated in urine. The HPLC profiles of the urine samples of both mouse strains treated with each enantiomer were qualitatively similar, but differences were found in a relatively higher proportion of several detected metabolites in mice treated with (R)-PAP compared with those treated with (S)-PAP. The main urine metabolite continues to be 2-hydroxy-3-(phenylamino)propanoic acid (1), which confirms our previous results obtained with rac-PAP. In addition to the detection of other metabolites already reported in our previous paper, interesting evidence is provided on the presence of 4-aminophenol and paracetamol conjugates in the urine samples from both mouse strains. The detection of these metabolites suggests the in vivo formation of quinoneimine PAP derivatives. Indeed, some quinoneimine species (11 and 12), as well as other PAP metabolites (13) that bear modifications in the alkyl chain, have been tentatively identified in mouse urine. These metabolic findings might imply a potential toxicological significance for the Toxic Oil Syndrome.
Warejko, Jillian K; Schueler, Markus; Vivante, Asaf; Tan, Weizhen; Daga, Ankana; Lawson, Jennifer A; Braun, Daniela A; Shril, Shirlee; Amann, Kassaundra; Somers, Michael J G; Rodig, Nancy M; Baum, Michelle A; Daouk, Ghaleb; Traum, Avram Z; Kim, Heung Bae; Vakili, Khashayar; Porras, Diego; Lock, James; Rivkin, Michael J; Chaudry, Gulraiz; Smoot, Leslie B; Singh, Michael N; Smith, Edward R; Mane, Shrikant M; Lifton, Richard P; Stein, Deborah R; Ferguson, Michael A; Hildebrandt, Friedhelm
2018-04-01
Midaortic syndrome (MAS) is a rare cause of severe childhood hypertension characterized by narrowing of the abdominal aorta in children and is associated with extensive vascular disease. It may occur as part of a genetic syndrome, such as neurofibromatosis, or as consequence of a pathological inflammatory disease. However, most cases are considered idiopathic. We hypothesized that in a high percentage of these patients, a monogenic cause of disease may be detected by evaluating whole exome sequencing data for mutations in 1 of 38 candidate genes previously described to cause vasculopathy. We studied a cohort of 36 individuals from 35 different families with MAS by exome sequencing. In 15 of 35 families (42.9%), we detected likely causal dominant mutations. In 15 of 35 (42.9%) families with MAS, whole exome sequencing revealed a mutation in one of the genes previously associated with vascular disease ( NF1 , JAG1 , ELN , GATA6 , and RNF213 ). Ten of the 15 mutations have not previously been reported. This is the first report of ELN , RNF213 , or GATA6 mutations in individuals with MAS. Mutations were detected in NF1 (6/15 families), JAG1 (4/15 families), ELN (3/15 families), and one family each for GATA6 and RNF213 Eight individuals had syndromic disease and 7 individuals had isolated MAS. Whole exome sequencing can provide conclusive molecular genetic diagnosis in a high fraction of individuals with syndromic or isolated MAS. Establishing an etiologic diagnosis may reveal genotype/phenotype correlations for MAS in the future and should, therefore, be performed routinely in MAS. © 2018 American Heart Association, Inc.
[Computerised monitoring of integrated cervical screening. Indicators of diagnostic performance].
Bucchi, L; Pierri, C; Amadori, A; Folicaldi, S; Ghidoni, D; Nannini, R; Bondi, A
2003-12-01
In a previous issue of this journal, we presented the background, rationale, general methods, and indicators of participation of a computerised system for the monitoring of integrated cervical screening, i.e. the integration of spontaneous Pap smear practice into organised screening. We also reported the results of the application of those indicators in the general database of the Pathology Department of Imola Health District in northern Italy. In the current paper, we present the rationale and definitions of indicators of diagnostic performance (total Pap smears and rate of unsatisfactory Pap smears, distribution by cytology class reported, rate of patients without timely follow-up, detection rate, positive predictive value, distribution of cytology classes reported by histology diagnosis, and distribution of cases of CIN and carcinoma registered by detection modality) as well as the results of their application in the same database as above.
The scenario of norovirus contamination in food and food handlers.
Tuan Zainazor, C; Hidayah, M S Noor; Chai, L C; Tunung, R; Ghazali, F Mohamad; Son, R
2010-02-01
Recently, many cases related to viral gastroenteritis outbreaks have been reported all over the world. Noroviruses are found to be leading as the major cause of outbreaks of acute gastroenteritis. Patients with the acute gastroenteritis normally found to be positive with norovirus when stools and vomit were analyzed. This paper reviews various activities and previous reports that describe norovirus contaminated in various food matrixes and relationship between food handlers. Lately, a numbers of norovirus outbreaks have been reported which are involved fresh produce (such as vegetables, fruits), shellfish and prepared food. Food produces by infected food handlers may therefore easily contaminated. In addition, food that required much handling and have been eaten without heat treatment gave the high risk for getting foodborne illnesses. The standard method for detection of norovirus has already been available for stool samples. However, only few methods for detection of norovirus in food samples have been developed until now.
Application of nonlinear ultrasonics to inspection of stainless steel for dry storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ulrich, Timothy James II; Anderson, Brain E.; Remillieux, Marcel C.
This report summarized technical work conducted by LANL staff an international collaborators in support of the UFD Storage Experimentation effort. The focus of the current technical work is on the detection and imaging of a failure mechanism known as stress corrosion cracking (SCC) in stainless steel using the nonlinear ultrasonic technique known as TREND. One of the difficulties faced in previous work is in finding samples that contain realistically sized SCC. This year such samples were obtained from EPRI. Reported here are measurements made on these samples. One of the key findings is the ability to detect subsurface changes tomore » the direction in which a crack is penetrating into the sample. This result follows from last year's report that demonstrated the ability of TREND techniques to image features below the sample surface. A new collaboration was established with AGH University of Science and Technology, Krakow, Poland.« less
Robo-AO Kepler Survey. IV. The Effect of Nearby Stars on 3857 Planetary Candidate Systems
NASA Astrophysics Data System (ADS)
Ziegler, Carl; Law, Nicholas M.; Baranec, Christoph; Riddle, Reed; Duev, Dmitry A.; Howard, Ward; Jensen-Clem, Rebecca; Kulkarni, S. R.; Morton, Tim; Salama, Maïssa
2018-04-01
We present the overall statistical results from the Robo-AO Kepler planetary candidate survey, comprising of 3857 high-angular resolution observations of planetary candidate systems with Robo-AO, an automated laser adaptive optics system. These observations reveal previously unknown nearby stars blended with the planetary candidate host stars that alter the derived planetary radii or may be the source of an astrophysical false positive transit signal. In the first three papers in the survey, we detected 440 nearby stars around 3313 planetary candidate host stars. In this paper, we present observations of 532 planetary candidate host stars, detecting 94 companions around 88 stars; 84 of these companions have not previously been observed in high resolution. We also report 50 more-widely separated companions near 715 targets previously observed by Robo-AO. We derive corrected planetary radius estimates for the 814 planetary candidates in systems with a detected nearby star. If planetary candidates are equally likely to orbit the primary or secondary star, the radius estimates for planetary candidates in systems with likely bound nearby stars increase by a factor of 1.54, on average. We find that 35 previously believed rocky planet candidates are likely not rocky due to the presence of nearby stars. From the combined data sets from the complete Robo-AO KOI survey, we find that 14.5 ± 0.5% of planetary candidate hosts have a nearby star with 4″, while 1.2% have two nearby stars, and 0.08% have three. We find that 16% of Earth-sized, 13% of Neptune-sized, 14% of Saturn-sized, and 19% of Jupiter-sized planet candidates have detected nearby stars.
Characterization of Fissile Assemblies Using Low-Efficiency Detection Systems
Chapline, George F.; Verbeke, Jerome M.
2017-02-02
Here, we have investigated the possibility that the amount, chemical form, multiplication, and shape of the fissile material in an assembly can be passively assayed using scintillator detection systems by only measuring the fast neutron pulse height distribution and distribution of time intervals Δt between fast neutrons. We have previously demonstrated that the alpha-ratio can be obtained from the observed pulse height distribution for fast neutrons. In this paper we report that we report that when the distribution of time intervals is plotted as a function of logΔt, the position of the correlated neutron peak is nearly independent of detectormore » efficiency and determines the internal relaxation rate for fast neutrons. If this information is combined with knowledge of the alpha-ratio, then the position of the minimum between the correlated and uncorrelated peaks can be used to rapidly estimate the mass, multiplication, and shape of fissile material. This method does not require a priori knowledge of either the efficiency for neutron detection or the alpha-ratio. Although our method neglects 3-neutron correlations, we have used previously obtained experimental data for metallic and oxide forms of Pu to demonstrate that our method yields good estimates for multiplications as large as 2, and that the only constraint on detector efficiency/observation time is that a peak in the interval time distribution due to correlated neutrons is visible.« less
NASA Astrophysics Data System (ADS)
Aab, A.; Abreu, P.; Aglietta, M.; Samarai, I. Al; Albuquerque, I. F. M.; Allekotte, I.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Anastasi, G. A.; Anchordoqui, L.; Andrada, B.; Andringa, S.; Aramo, C.; Arqueros, F.; Arsene, N.; Asorey, H.; Assis, P.; Aublin, J.; Avila, G.; Badescu, A. M.; Balaceanu, A.; Barreira Luz, R. J.; Baus, C.; Beatty, J. J.; Becker, K. H.; Bellido, J. A.; Berat, C.; Bertaina, M. E.; Bertou, X.; Biermann, P. L.; Billoir, P.; Biteau, J.; Blaess, S. G.; Blanco, A.; Blazek, J.; Bleve, C.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Borodai, N.; Botti, A. M.; Brack, J.; Brancus, I.; Bretz, T.; Bridgeman, A.; Briechle, F. L.; Buchholz, P.; Bueno, A.; Buitink, S.; Buscemi, M.; Caballero-Mora, K. S.; Caccianiga, L.; Cancio, A.; Canfora, F.; Caramete, L.; Caruso, R.; Castellina, A.; Cataldi, G.; Cazon, L.; Chavez, A. G.; Chinellato, J. A.; Chudoba, J.; Clay, R. W.; Colalillo, R.; Coleman, A.; Collica, L.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cooper, M. J.; Coutu, S.; Covault, C. E.; Cronin, J.; D'Amico, S.; Daniel, B.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; de Jong, S. J.; De Mauro, G.; de Mello Neto, J. R. T.; De Mitri, I.; de Oliveira, J.; de Souza, V.; Debatin, J.; Deligny, O.; Di Giulio, C.; Di Matteo, A.; Díaz Castro, M. L.; Diogo, F.; Dobrigkeit, C.; D'Olivo, J. C.; dos Anjos, R. C.; Dova, M. T.; Dundovic, A.; Ebr, J.; Engel, R.; Erdmann, M.; Erfani, M.; Escobar, C. O.; Espadanal, J.; Etchegoyen, A.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Fick, B.; Figueira, J. M.; Filipčič, A.; Fratu, O.; Freire, M. M.; Fujii, T.; Fuster, A.; Gaior, R.; García, B.; Garcia-Pinto, D.; Gaté, F.; Gemmeke, H.; Gherghel-Lascu, A.; Ghia, P. L.; Giaccari, U.; Giammarchi, M.; Giller, M.; Głas, D.; Glaser, C.; Golup, G.; Gómez Berisso, M.; Gómez Vitale, P. F.; González, N.; Gorgi, A.; Gorham, P.; Gouffon, P.; Grillo, A. F.; Grubb, T. D.; Guarino, F.; Guedes, G. P.; Hampel, M. R.; Hansen, P.; Harari, D.; Harrison, T. A.; Harton, J. L.; Hasankiadeh, Q.; Haungs, A.; Hebbeker, T.; Heck, D.; Heimann, P.; Herve, A. E.; Hill, G. C.; Hojvat, C.; Holt, E.; Homola, P.; Hörandel, J. R.; Horvath, P.; Hrabovský, M.; Huege, T.; Hulsman, J.; Insolia, A.; Isar, P. G.; Jandt, I.; Jansen, S.; Johnsen, J. A.; Josebachuili, M.; Kääpä, A.; Kambeitz, O.; Kampert, K. H.; Katkov, I.; Keilhauer, B.; Kemp, E.; Kemp, J.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Krause, R.; Krohm, N.; Kuempel, D.; Kukec Mezek, G.; Kunka, N.; Kuotb Awad, A.; LaHurd, D.; Lauscher, M.; Legumina, R.; Leigui de Oliveira, M. A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; Lopes, L.; López, R.; López Casado, A.; Luce, Q.; Lucero, A.; Malacari, M.; Mallamaci, M.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Mariş, I. C.; Marsella, G.; Martello, D.; Martinez, H.; Martínez Bravo, O.; Masías Meza, J. J.; Mathes, H. J.; Mathys, S.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Mayotte, E.; Mazur, P. O.; Medina, C.; Medina-Tanco, G.; Melo, D.; Menshikov, A.; Messina, S.; Micheletti, M. I.; Middendorf, L.; Minaya, I. A.; Miramonti, L.; Mitrica, B.; Mockler, D.; Mollerach, S.; Montanet, F.; Morello, C.; Mostafá, M.; Müller, A. L.; Müller, G.; Muller, M. A.; Müller, S.; Mussa, R.; Naranjo, I.; Nellen, L.; Nguyen, P. H.; Niculescu-Oglinzanu, M.; Niechciol, M.; Niemietz, L.; Niggemann, T.; Nitz, D.; Nosek, D.; Novotny, V.; Nožka, H.; Núñez, L. A.; Ochilo, L.; Oikonomou, F.; Olinto, A.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Papenbreer, P.; Parente, G.; Parra, A.; Paul, T.; Pech, M.; Pedreira, F.; Pȩkala, J.; Pelayo, R.; Peña-Rodriguez, J.; Pereira, L. A. S.; Perlín, M.; Perrone, L.; Peters, C.; Petrera, S.; Phuntsok, J.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Plum, M.; Porowski, C.; Prado, R. R.; Privitera, P.; Prouza, M.; Quel, E. J.; Querchfeld, S.; Quinn, S.; Ramos-Pollan, R.; Rautenberg, J.; Ravignani, D.; Revenu, B.; Ridky, J.; Risse, M.; Ristori, P.; Rizi, V.; Rodrigues de Carvalho, W.; Rodriguez Fernandez, G.; Rodriguez Rojo, J.; Rogozin, D.; Roncoroni, M. J.; Roth, M.; Roulet, E.; Rovero, A. C.; Ruehl, P.; Saffi, S. J.; Saftoiu, A.; Salazar, H.; Saleh, A.; Salesa Greus, F.; Salina, G.; Sánchez, F.; Sanchez-Lucas, P.; Santos, E. M.; Santos, E.; Sarazin, F.; Sarmento, R.; Sarmiento, C. A.; Sato, R.; Schauer, M.; Scherini, V.; Schieler, H.; Schimp, M.; Schmidt, D.; Scholten, O.; Schovánek, P.; Schröder, F. G.; Schulz, A.; Schulz, J.; Schumacher, J.; Sciutto, S. J.; Segreto, A.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sigl, G.; Silli, G.; Sima, O.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sonntag, S.; Sorokin, J.; Squartini, R.; Stanca, D.; Stanič, S.; Stasielak, J.; Stassi, P.; Strafella, F.; Suarez, F.; Suarez Durán, M.; Sudholz, T.; Suomijärvi, T.; Supanitsky, A. D.; Swain, J.; Szadkowski, Z.; Taboada, A.; Taborda, O. A.; Tapia, A.; Theodoro, V. M.; Timmermans, C.; Todero Peixoto, C. J.; Tomankova, L.; Tomé, B.; Torralba Elipe, G.; Torri, M.; Travnicek, P.; Trini, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van Aar, G.; van Bodegom, P.; van den Berg, A. M.; van Vliet, A.; Varela, E.; Vargas Cárdenas, B.; Varner, G.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Vergara Quispe, I. D.; Verzi, V.; Vicha, J.; Villaseñor, L.; Vorobiov, S.; Wahlberg, H.; Wainberg, O.; Walz, D.; Watson, A. A.; Weber, M.; Weindl, A.; Wiencke, L.; Wilczyński, H.; Winchen, T.; Wittkowski, D.; Wundheiler, B.; Yang, L.; Yelos, D.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zepeda, A.; Zimmermann, B.; Ziolkowski, M.; Zong, Z.; Zuccarello, F.
2017-06-01
We report a multi-resolution search for anisotropies in the arrival directions of cosmic rays detected at the Pierre Auger Observatory with local zenith angles up to 80o and energies in excess of 4 EeV (4 × 1018 eV). This search is conducted by measuring the angular power spectrum and performing a needlet wavelet analysis in two independent energy ranges. Both analyses are complementary since the angular power spectrum achieves a better performance in identifying large-scale patterns while the needlet wavelet analysis, considering the parameters used in this work, presents a higher efficiency in detecting smaller-scale anisotropies, potentially providing directional information on any observed anisotropies. No deviation from isotropy is observed on any angular scale in the energy range between 4 and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured; while no other deviation from isotropy is observed for moments beyond the dipole one. The corresponding p-values obtained after accounting for searches blindly performed at several angular scales, are 1.3 × 10-5 in the case of the angular power spectrum, and 2.5 × 10-3 in the case of the needlet analysis. While these results are consistent with previous reports making use of the same data set, they provide extensions of the previous works through the thorough scans of the angular scales.
Does fatigue have any impact on satisfaction of search?
NASA Astrophysics Data System (ADS)
Krupinski, Elizabeth A.; Schartz, Kevin; Caldwell, Robert; Madsen, Mark; Berbaum, Kevin S.
2017-03-01
Previous studies have demonstrated that fatigue impacts diagnostic accuracy, especially for those in training. We continued this line of investigation to determine if fatigue has any impact on a common source of errors - satisfaction of search (SOS). SOS requires subjects to participate in 2 sessions (SOS and non-SOS) and so does fatigue (fatigued and not fatigued) so we ran subjets in only the fatigued condition and used a previous non-fatigued study as the comparison. We used 64 chest computed radiographs half demonstrating various ``test'' abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Adding nodules did not influence detection accuracy (ROC AUC SOS = 0.667; non-SOS = 0.679), but did induce a reluctance to report them. Adding nodules did not affect inspection time so the reluctance to report was not associated with reduced search. Fatigue did not appear to exacerbate the SOS effect. A second study with fractures revealed the same shift in performance but did reduce viewing times when fatigued. The results of these two studies suggest that the impact of fatigue on SOS is more complicated than expected and thus may require more investigation to fully understand its impact in the clinic.
UV plasmonic device for sensing ethanol and acetone
NASA Astrophysics Data System (ADS)
Honda, Mitsuhiro; Ichikawa, Yo; Rozhin, Alex G.; Kulinich, Sergei A.
2018-01-01
In the present study, we demonstrate efficient detection of volatile organic vapors with improved sensitivity, exploiting the localized surface plasmon resonance of indium nanograins in the UV range (UV-LSPR). The sensitivity of deep-UV-LSPR measurements toward ethanol was observed to be 0.004 nm/ppm, which is 10 times higher than that of a previously reported visible-LSPR device based on Ag nanoprisms [Sensors 11, 8643 (2011)]. Although practical issues such as improving detection limits are still remaining, the results of the present study suggest that the new approach based on UV-LSPR may open new avenues to the detection of organic molecules in solid, liquid, and gas phases using plasmonic sensors.
Bjurlin, Marc A; Meng, Xiaosong; Le Nobin, Julien; Wysock, James S; Lepor, Herbert; Rosenkrantz, Andrew B; Taneja, Samir S
2014-09-01
Optimization of prostate biopsy requires addressing the shortcomings of standard systematic transrectal ultrasound guided biopsy, including false-negative rates, incorrect risk stratification, detection of clinically insignificant disease and the need for repeat biopsy. Magnetic resonance imaging is an evolving noninvasive imaging modality that increases the accurate localization of prostate cancer at the time of biopsy, and thereby enhances clinical risk assessment and improves the ability to appropriately counsel patients regarding therapy. In this review we 1) summarize the various sequences that comprise a prostate multiparametric magnetic resonance imaging examination along with its performance characteristics in cancer detection, localization and reporting standards; 2) evaluate potential applications of magnetic resonance imaging targeting in prostate biopsy among men with no previous biopsy, a negative previous biopsy and those with low stage cancer; and 3) describe the techniques of magnetic resonance imaging targeted biopsy and comparative study outcomes. A bibliographic search covering the period up to October 2013 was conducted using MEDLINE®/PubMed®. Articles were reviewed and categorized based on which of the 3 objectives of this review was addressed. Data were extracted, analyzed and summarized. Multiparametric magnetic resonance imaging consists of anatomical T2-weighted imaging coupled with at least 2 functional imaging techniques. It has demonstrated improved prostate cancer detection sensitivity up to 80% in the peripheral zone and 81% in the transition zone. A prostate cancer magnetic resonance imaging suspicion score has been developed, and is depicted using the Likert or PI-RADS (Prostate Imaging Reporting and Data System) scale for better standardization of magnetic resonance imaging interpretation and reporting. Among men with no previous biopsy, magnetic resonance imaging increases the frequency of significant cancer detection to 50% in low risk and 71% in high risk patients. In low risk men the negative predictive value of a combination of negative magnetic resonance imaging with prostate volume parameters is nearly 98%, suggesting a potential role in avoiding biopsy and reducing over detection/overtreatment. Among men with a previous negative biopsy 72% to 87% of cancers detected by magnetic resonance imaging guidance are clinically significant. Among men with a known low risk cancer, repeat biopsy using magnetic resonance targeting demonstrates a high likelihood of confirming low risk disease in low suspicion score lesions and of upgrading in high suspicion score lesions. Techniques of magnetic resonance imaging targeted biopsy include visual estimation transrectal ultrasound guided biopsy; software co-registered magnetic resonance imaging-ultrasound, transrectal ultrasound guided biopsy; and in-bore magnetic resonance imaging guided biopsy. Although the improvement in accuracy and efficiency of visual estimation biopsy compared to systematic appears limited, co-registered magnetic resonance imaging-ultrasound biopsy as well as in-bore magnetic resonance imaging guided biopsy appear to increase cancer detection rates in conjunction with increasing suspicion score. Use of magnetic resonance imaging for targeting prostate biopsies has the potential to reduce the sampling error associated with conventional biopsy by providing better disease localization and sampling. More accurate risk stratification through improved cancer sampling may impact therapeutic decision making. Optimal clinical application of magnetic resonance imaging targeted biopsy remains under investigation. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Kubanek, Jan; Snyder, Lawrence H.
2017-01-01
Abstract Behavior is guided by previous experience. Good, positive outcomes drive a repetition of a previous behavior or choice, whereas poor or bad outcomes lead to an avoidance. How these basic drives are implemented by the brain has been of primary interest to psychology and neuroscience. We engaged animals in a choice task in which the size of a reward outcome strongly governed the animals' subsequent decision whether to repeat or switch the previous choice. We recorded the discharge activity of neurons implicated in reward-based choice in 2 regions of parietal cortex. We found that the tendency to retain previous choice following a large (small) reward was paralleled by a marked decrease (increase) in the activity of parietal neurons. This neural effect is independent of, and of sign opposite to, value-based modulations reported in parietal cortex previously. This effect shares the same basic properties with signals previously reported in the limbic system that detect the size of the recently obtained reward to mediate proper repeat-switch decisions. We conclude that the size of the obtained reward is a decision variable that guides the decision between retaining a choice or switching, and neurons in parietal cortex strongly respond to this novel decision variable. PMID:26491065
Pham, Thuy T; Moore, Steven T; Lewis, Simon John Geoffrey; Nguyen, Diep N; Dutkiewicz, Eryk; Fuglevand, Andrew J; McEwan, Alistair L; Leong, Philip H W
2017-11-01
Freezing of gait (FoG) is common in Parkinsonian gait and strongly relates to falls. Current clinical FoG assessments are patients' self-report diaries and experts' manual video analysis. Both are subjective and yield moderate reliability. Existing detection algorithms have been predominantly designed in subject-dependent settings. In this paper, we aim to develop an automated FoG detector for subject independent. After extracting highly relevant features, we apply anomaly detection techniques to detect FoG events. Specifically, feature selection is performed using correlation and clusterability metrics. From a list of 244 feature candidates, 36 candidates were selected using saliency and robustness criteria. We develop an anomaly score detector with adaptive thresholding to identify FoG events. Then, using accuracy metrics, we reduce the feature list to seven candidates. Our novel multichannel freezing index was the most selective across all window sizes, achieving sensitivity (specificity) of (). On the other hand, freezing index from the vertical axis was the best choice for a single input, achieving sensitivity (specificity) of () for ankle and () for back sensors. Our subject-independent method is not only significantly more accurate than those previously reported, but also uses a much smaller window (e.g., versus ) and/or lower tolerance (e.g., versus ).Freezing of gait (FoG) is common in Parkinsonian gait and strongly relates to falls. Current clinical FoG assessments are patients' self-report diaries and experts' manual video analysis. Both are subjective and yield moderate reliability. Existing detection algorithms have been predominantly designed in subject-dependent settings. In this paper, we aim to develop an automated FoG detector for subject independent. After extracting highly relevant features, we apply anomaly detection techniques to detect FoG events. Specifically, feature selection is performed using correlation and clusterability metrics. From a list of 244 feature candidates, 36 candidates were selected using saliency and robustness criteria. We develop an anomaly score detector with adaptive thresholding to identify FoG events. Then, using accuracy metrics, we reduce the feature list to seven candidates. Our novel multichannel freezing index was the most selective across all window sizes, achieving sensitivity (specificity) of (). On the other hand, freezing index from the vertical axis was the best choice for a single input, achieving sensitivity (specificity) of () for ankle and () for back sensors. Our subject-independent method is not only significantly more accurate than those previously reported, but also uses a much smaller window (e.g., versus ) and/or lower tolerance (e.g., versus ).
Non-lethal sampling for the detection of Myxobolus cerebralis in asymptomatic rainbow trout
Schill, Bane; Waldrop, Thomas; Densmore, Christine; Blazer, Vicki
1999-01-01
We have described in previous reports (Schill et al., 1998) the development of a polymerase chain reaction (PCR) amplification of 18S ribosomal RNA for the detection of Myxozoan parasites. Oligonucleotide primers were developed by multiple alignment of Myxozoan sequence information and analysis by a custom-written computer program (PRIM). Candidate pairs of primer sequences were then analyzed for specificity by BLAST (Basic Local Alignment Search Tool). From these, a set of promising primers (MYXFWD and MYXREV) was chosen for further testing. These were chosen because they should direct detection of a number of Myxozoan species (Table 1). PCR using MXYFWD and MYXREV proved to be robust and relatively free of artifact products. Further, we were able to routinely detect Myxobolus cerebralis in fish tissues (Figure 1).
Quantitative surface-enhanced resonance Raman scattering of phthalocyanine-labelled oligonucleotides
Macaskill, A.; Chernonosov, A. A.; Koval, V. V.; Lukyanets, E. A.; Fedorova, O. S.; Smith, W. E.; Faulds, K.; Graham, D.
2007-01-01
The evaluation of phthalocyanine labels for the surface-enhanced resonance Raman scattering (SERRS) detection of oligonucleotides is reported. Three phthalocyanine-labelled oligonucleotides were assessed, each containing a different metal centre. Detection limits for each labelled oligonucleotide were determined using two excitation frequencies where possible. Limits of detection as low as 2.8 × 10−11 mol. dm−3 were obtained which are comparable to standard fluorescently labelled probes used in previous SERRS studies. The identification of two phthalocyanine-labelled oligonucleotides without separation was also demonstrated indicating their suitability for multiplexing. This study extends the range of labels suitable for quantitative surface-enhanced resonance Raman scattering with silver nanoparticles and offers more flexibility and choice when considering SERRS for quantitative DNA detection. PMID:17289751
Desflurane Hepatitis Associated with Hapten and Autoantigen-Specific IgG4 Antibodies
Anderson, James S.; Rose, Noel R.; Martin, Jackie L.; Eger, Edmond I.; Njoku, Dolores B.
2013-01-01
BACKGROUND Three cases of drug-induced liver injury (DILI) have been reported after desflurane anesthesia. However, no previous reports have detected serum autoantibodies such as that reported with DILI from halothane or isoflurane. METHODS AND RESULTS We describe the first documentation of cytochrome P450 2E1 IgG4 autoantibodies, as well as 58 kDa endoplasmic reticulum protein and trifluoroacetyl chloride hapten-specific IgG4 antibodies, in a patient who developed DILI after desflurane anesthesia. CONCLUSIONS These findings suggest that allergic and autoimmune mechanisms have critical roles in the development of desflurane DILI. PMID:17513640
Li, Chuang; Gong, Wenbing; Zhang, Lin; Yang, Zhiquan; Nong, Wenyan; Bian, Yinbing; Kwan, Hoi-Shan; Cheung, Man-Kit; Xiao, Yang
2017-01-01
Association mapping is a robust approach for the detection of quantitative trait loci (QTLs). Here, by genotyping 297 genome-wide molecular markers of 89 Lentinula edodes cultivars in China, the genetic diversity, population structure and genetic loci associated with 11 agronomic traits were examined. A total of 873 alleles were detected in the tested strains with a mean of 2.939 alleles per locus, and the Shannon's information index was 0.734. Population structure analysis revealed two robustly differentiated groups among the Chinese L. edodes cultivars (FST = 0.247). Using the mixed linear model, a total of 43 markers were detected to be significantly associated with four traits. The number of markers associated with traits ranged from 9 to 26, and the phenotypic variations explained by each marker varied from 12.07% to 31.32%. Apart from five previously reported markers, the remaining 38 markers were newly reported here. Twenty-one markers were identified as simultaneously linked to two to four traits, and five markers were associated with the same traits in cultivation tests performed in two consecutive years. The 43 traits-associated markers were related to 97 genes, and 24 of them were related to 10 traits-associated markers detected in both years or identified previously, 13 of which had a >2-fold expression change between the mycelium and primordium stages. Our study has provided candidate markers for marker-assisted selection (MAS) and useful clues for understanding the genetic architecture of agronomic traits in the shiitake mushroom. PMID:28261189
Safety and clinical performance of acoustic reflex tests.
Hunter, L L; Ries, D T; Schlauch, R S; Levine, S C; Ward, W D
1999-12-01
Safety and effectiveness of acoustic reflex tests are important issues because these tests are widely applied to screen for retrocochlear pathology. Previous studies have reported moderately high sensitivity and specificity for detection of acoustic neuroma. However, there have been reports of possible iatrogenic hearing loss resulting from acoustic reflex threshold (ART) and decay (ARD) tests. This study assessed safety and clinical performance of ART tests for detection of acoustic neuroma. We report a case in which ARD testing resulted in a significant bilateral permanent threshold shift. This case was the impetus for us to investigate the clinical utility of ART and ARD tests. We analyzed sensitivity and specificity of ART, as well as asymmetry in pure-tone thresholds (PTT) for detection of acoustic neuroma in 56 tumor and 108 non-tumor ears. Sensitivity and specificity were higher for PTT asymmetry than for ART. Ipsilateral ART at 1000 Hz had poor sensitivity and specificity for detection of acoustic neuroma, and involves some potential risk to residual hearing for presentation levels higher than 115 dB SPL. Approximately half of the acoustic neuroma group had ipsilateral ARTs that would require administration of ARD tests at levels exceeding 115 dB SPL. Therefore, we conclude that PTT asymmetry is a more effective test for detection of acoustic neuroma, and involves no risk to residual hearing. Future studies of contralateral reflex threshold and ARD in combination with PTT asymmetry are recommended.
Sridhar, Vivek Kumar Rangarajan; Bangalore, Srinivas; Narayanan, Shrikanth S.
2009-01-01
In this paper, we describe a maximum entropy-based automatic prosody labeling framework that exploits both language and speech information. We apply the proposed framework to both prominence and phrase structure detection within the Tones and Break Indices (ToBI) annotation scheme. Our framework utilizes novel syntactic features in the form of supertags and a quantized acoustic–prosodic feature representation that is similar to linear parameterizations of the prosodic contour. The proposed model is trained discriminatively and is robust in the selection of appropriate features for the task of prosody detection. The proposed maximum entropy acoustic–syntactic model achieves pitch accent and boundary tone detection accuracies of 86.0% and 93.1% on the Boston University Radio News corpus, and, 79.8% and 90.3% on the Boston Directions corpus. The phrase structure detection through prosodic break index labeling provides accuracies of 84% and 87% on the two corpora, respectively. The reported results are significantly better than previously reported results and demonstrate the strength of maximum entropy model in jointly modeling simple lexical, syntactic, and acoustic features for automatic prosody labeling. PMID:19603083
A nanocomposite-based electrochemical sensor for non-enzymatic detection of hydrogen peroxide
Du, Xin; Chen, Yuan; Dong, Wenhao; Han, Bingkai; Liu, Min; Chen, Qiang; Zhou, Jun
2017-01-01
Hydrogen peroxide (H2O2) plays important signaling roles in normal physiology and disease. However, analyzing the actions of H2O2 is often impeded by the difficulty in detecting this molecule. Herein, we report a novel nanocomposite-based electrochemical sensor for non-enzymatic detection of H2O2. Graphene oxide (GO) was selected as the dopant for the synthesis of polyaniline (PANI), leading to the successful fabrication of a water-soluble and stable GO-PANI composite. GO-PANI was subsequently subject to cyclic voltammetry to generate reduced GO-PANI (rGO-PANI), enhancing the conductivity of the material. Platinum nanoparticles (PtNPs) were then electrodeposited on the surface of the rGO-PANI-modified glassy carbon electrode (GCE) to form an electrochemical H2O2 sensor. Compared to previously reported sensors, the rGO-PANI-PtNP/GCE exhibited an expanded linear range, higher sensitivity, and lower detection limit in the quantification of H2O2. In addition, the sensor displayed outstanding reproducibility and selectivity in real-sample examination. Our study suggests that the rGO-PANI-PtNP/GCE may have broad utility in H2O2 detection under physiological and pathological conditions. PMID:28035076
Detection of Avian Influenza Virus from Cloacal Swabs Using a Disposable Well Gate FET Sensor.
Park, Sungwook; Choi, Jaebin; Jeun, Minhong; Kim, Yongdeok; Yuk, Seong-Su; Kim, Sang Kyung; Song, Chang-Seon; Lee, Seok; Lee, Kwan Hyi
2017-07-01
Current methods to detect avian influenza viruses (AIV) are time consuming and lo inw sensitivity, necessitating a faster and more sensitive sensor for on-site epidemic detection in poultry farms and urban population centers. This study reports a field effect transistor (FET) based AIV sensor that detects nucleoproteins (NP) within 30 minutes, down to an LOD of 10 3 EID 50 mL -1 from a live animal cloacal swab. Previously reported FET sensors for AIV detection have not targeted NPs, an internal protein shared across multiple strains, due to the difficulty of field-effect sensing in a highly ionic lysis buffer. The AIV sensor overcomes the sensitivity limit with an FET-based platform enhanced with a disposable well gate (DWG) that is readily replaceable after each measurement. In a single procedure, the virus-containing sample is immersed in a lysis buffer mixture to expose NPs to the DWG surface. In comparison with commercial AIV rapid kits, the AIV sensor is proved to be highly sensitive, fast, and compact, proving its potential effectiveness as a portable biosensor. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Amplified and in situ detection of redox-active metabolite using a biobased redox capacitor.
Kim, Eunkyoung; Gordonov, Tanya; Bentley, William E; Payne, Gregory F
2013-02-19
Redox cycling provides a mechanism to amplify electrochemical signals for analyte detection. Previous studies have shown that diverse mediators/shuttles can engage in redox-cycling reactions with a biobased redox capacitor that is fabricated by grafting redox-active catechols onto a chitosan film. Here, we report that redox cycling with this catechol-chitosan redox capacitor can amplify electrochemical signals for detecting a redox-active bacterial metabolite. Specifically, we studied the redox-active bacterial metabolite pyocyanin that is reported to be a virulence factor and signaling molecule for the opportunistic pathogen P. aeruginosa. We demonstrate that redox cycling can amplify outputs from various electrochemical methods (cyclic voltammetry, chronocoulometry, and differential pulse voltammetry) and can lower the detection limit of pyocyanin to 50 nM. Further, the compatibility of this biobased redox capacitor allows the in situ monitoring of the production of redox-active metabolites (e.g., pyocyanin) during the course of P. aeruginosa cultivation. We anticipate that the amplified output of redox-active virulence factors should permit an earlier detection of life-threatening infections by the opportunistic pathogen P. aeruginosa while the "bio-compatibility" of this measurement approach should facilitate in situ study of the spatiotemporal dynamics of bacterial redox signaling.
Systematic screening for CYP3A4 genetic polymorphisms in a Han Chinese population.
Hu, Guo-Xin; Dai, Da-Peng; Wang, Hao; Huang, Xiang-Xin; Zhou, Xiao-Yang; Cai, Jie; Chen, Hao; Cai, Jian-Ping
2017-03-01
To systematically investigate the genetic polymorphisms of the CYP3A4 gene in a Han Chinese population. The promoter and exons of CYP3A4 gene in 1114 unrelated, healthy Han Chinese subjects were amplified and genotyped by direct sequencing. In total, five previously reported alleles (*1G, *4, *5, *18B and *23) were detected, of which one allele (*23) was reported for the first time in Han Chinese population. Additionally, seven novel exonic variants were also identified and designated as new alleles CYP3A4*28-*34. This study provides the most comprehensive data of CYP3A4 polymorphisms in Han Chinese population and detects the largest number of novel CYP3A4 alleles in one ethnic group.
West Nile virus activity--United States, January 1-December 1, 2005.
2005-12-16
West Nile virus (WNV) is the leading cause of arboviral encephalitis in the United States. Originally discovered in Africa in 1937, WNV was first detected in the western hemisphere in 1999 in New York City. Since then it has caused seasonal epidemics of febrile illness and severe neurologic disease. During January 1-December 1, 2005, a total of 2,744 cases of WNV disease in humans were reported in the United States, an increase from 2,359 during the same period in 2004. A total of 1,165 cases were WNV neuroinvasive disease (WNND). WNV infections in humans, birds, mosquitoes, and nonhuman mammals are reported to CDC through ArboNET, an Internet-based arbovirus surveillance system managed by state health departments and CDC. During 2005, WNV transmission to humans or animals expanded into 21 counties that had not previously reported transmission and recurred in 1,196 counties where transmission had been reported in previous years. This report summarizes provisional WNV surveillance data through December 1, 2005, and highlights the need for ongoing surveillance, mosquito control, promotion of personal protection from mosquito bites, and research into additional prevention strategies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xianliang, Zhou; Mopper, K.
1990-10-01
Carbonyl compounds in clean marine air were trapped onto 2,4-dinitrophenylhydrazine- (DNPH-) coated cartridges, and their hydrazone derivatives were separated by HPLC and detected by UV absorbance. More than 20 carbonyl compounds were isolated from marine air with >92% collection efficiency. The technique employs a highly effective reagent purification procedure, which results in much lower blanks compared to previously reported trapping techniques for carbonyl compounds. Blanks were routinely <0.07 ppb for formaldehyde and acetone and <0.02 ppb for the others. Humidity and reactive gases have no detectable effect on collection efficiencies. Carbonyl-DNPH derivatives eluted from the cartridges are stable in acetonitrilemore » for at least 2 weeks, which facilitates field studies. Several previously undetected unknown carbonyl compounds were found in marine air by this technique. Typical results for open ocean and coastal marine air are shown.« less
Seroprevalence of Chikungunya Virus in a Rural Community in Brazil
Cunha, Rivaldo V.; Trinta, Karen S.; Montalbano, Camila A.; Sucupira, Michel V. F.; de Lima, Maricelia M.; Marques, Erenilde; Romanholi, Izilyanne H.
2017-01-01
Background The emergence of the Chikungunya virus (CHIKV) is currently expanding. In 2015, 38,332 cases of Chikungunya were reported to the Brazilian epidemiological surveillance system. Eighteen months after notification of the first case in the city of Feira de Santana, we conducted the first serosurvey to define the magnitude of transmission in a rural community in Brazil. Methodology/Main findings The serosurvey was conducted in a random sample of 450 residences in the Chapada district, located 100 kilometers from Feira de Santana. We administered questionnaires and tested 120 sera from Chapada district residents for CHIKV IgM- and IgG-specific antibodies. An individual with CHIKV infection was defined as any person with CHIKV IgM or IgG antibodies detected in the serum. One Hundred cases of Chikungunya were reported after prolonged rainfall, which reinforced the relationship between the rainfall index and CHIKV transmission. Eighteen months after the start of the outbreak, we identified a seroprevalence of 20% (95% CI, 15.4–35%). CHIKV IgG- and IgM-specific antibodies were detected in 22/120 (18.3%) and 6/120 (5.0%) individuals, respectively. Among seropositive patients, 13/24 (54.2%) reported fever and joint pain over the previous two years (p<0.01). The rate of symptomatic CHIKV infection was 40.7%. Conclusions/Significance We identified a moderate seroprevalence of Chikungunya in the Chapada district, and in half of the confirmed CHIKV infections, patients reported arthralgia and fever over the previous two years. PMID:28107342
Seroprevalence of Chikungunya Virus in a Rural Community in Brazil.
Cunha, Rivaldo V; Trinta, Karen S; Montalbano, Camila A; Sucupira, Michel V F; de Lima, Maricelia M; Marques, Erenilde; Romanholi, Izilyanne H; Croda, Julio
2017-01-01
The emergence of the Chikungunya virus (CHIKV) is currently expanding. In 2015, 38,332 cases of Chikungunya were reported to the Brazilian epidemiological surveillance system. Eighteen months after notification of the first case in the city of Feira de Santana, we conducted the first serosurvey to define the magnitude of transmission in a rural community in Brazil. The serosurvey was conducted in a random sample of 450 residences in the Chapada district, located 100 kilometers from Feira de Santana. We administered questionnaires and tested 120 sera from Chapada district residents for CHIKV IgM- and IgG-specific antibodies. An individual with CHIKV infection was defined as any person with CHIKV IgM or IgG antibodies detected in the serum. One Hundred cases of Chikungunya were reported after prolonged rainfall, which reinforced the relationship between the rainfall index and CHIKV transmission. Eighteen months after the start of the outbreak, we identified a seroprevalence of 20% (95% CI, 15.4-35%). CHIKV IgG- and IgM-specific antibodies were detected in 22/120 (18.3%) and 6/120 (5.0%) individuals, respectively. Among seropositive patients, 13/24 (54.2%) reported fever and joint pain over the previous two years (p<0.01). The rate of symptomatic CHIKV infection was 40.7%. We identified a moderate seroprevalence of Chikungunya in the Chapada district, and in half of the confirmed CHIKV infections, patients reported arthralgia and fever over the previous two years.
Ackermann, M.; Ajello, M.; Albert, A.; ...
2015-06-15
Dark matter in the Milky Way may annihilate directly into γ rays, producing a monoenergetic spectral line. Therefore, detecting such a signature would be strong evidence for dark matter annihilation or decay. We search for spectral lines in the Fermi Large Area Telescope observations of the Milky Way halo in the energy range 200 MeV–500 GeV using analysis methods from our most recent line searches. The main improvements relative to previous works are our use of 5.8 years of data reprocessed with the Pass 8 event-level analysis and the additional data resulting from the modified observing strategy designed to increasemore » exposure of the Galactic center region. Furthermore, we search in five sky regions selected to optimize sensitivity to different theoretically motivated dark matter scenarios and find no significant detections. In addition to presenting the results from our search for lines, we also investigate the previously reported tentative detection of a line at 133 GeV using the new Pass 8 data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Ann M.; Giovanelli, Riccardo; Haynes, Martha P.
We present a fourth catalog of H I sources from the Arecibo Legacy Fast ALFA (ALFALFA) Survey. We report 541 detections over 136 deg{sup 2}, within the region of the sky having 22{sup h} < {alpha} < 03{sup h} and 24 deg. < {delta} < 26 deg. This complements a previous catalog in the region 26 deg. < {delta} < 28 deg. We present here the detections falling into three classes: (1) extragalactic sources with signal-to-noise ratio (S/N)>6.5, where the reliability of the catalog is better than 95%; (2) extragalactic sources 5.0 < S/N < 6.5 and a previously measuredmore » optical redshift that corroborates our detection; or (3) High Velocity Clouds (HVCs), or subcomponents of such clouds, in the periphery of the Milky Way. Of the 541 objects presented here, 90 are associated with HVCs, while the remaining 451 are identified as extragalactic objects. Optical counterparts have been matched with all but one of the extragalactic objects.« less
NASA Astrophysics Data System (ADS)
Arkwright, J. W.; Blenman, N. G.; Underhill, I. D.; Maunder, S. A.; Spencer, N. J.; Costa, M.; Brooks, S. J.; Szczesniak, M. M.; Dinning, P. G.
2010-09-01
Diagnostic catheters based on fibre Bragg gratings (FBG's) are proving to be highly effective for measurement of the muscular activity associated with peristalsis in the human gut. The primary muscular contractions that generate peristalsis are circumferential in nature; however, it has long been known that there is also a component of longitudinal contractility present, acting in harmony with the circumferential component to improve the overall efficiency of material movement. To date, there have been relatively few reports on the measurement or inference of longitudinal contractions in humans and all have been limited to detection at a single location only. This is due to the lack of a viable recording technique suitable for real-time in-vivo measurement of this type of activity over extended lengths of the gut. We report the detection of longitudinal motion in lengths of excised mammalian colon using an FBG technique that should be viable for similar detection in humans. The longitudinal sensors have been combined with our previously reported FBG pressure sensing elements to form a composite catheter that allows the relative phase between the two components to be detected. The catheter output has been validated using digital video mapping in an ex-vivo animal preparation using lengths of rabbit ileum.
Generic Sensor Modeling Using Pulse Method
NASA Technical Reports Server (NTRS)
Helder, Dennis L.; Choi, Taeyoung
2005-01-01
Recent development of high spatial resolution satellites such as IKONOS, Quickbird and Orbview enable observation of the Earth's surface with sub-meter resolution. Compared to the 30 meter resolution of Landsat 5 TM, the amount of information in the output image was dramatically increased. In this era of high spatial resolution, the estimation of spatial quality of images is gaining attention. Historically, the Modulation Transfer Function (MTF) concept has been used to estimate an imaging system's spatial quality. Sometimes classified by target shapes, various methods were developed in laboratory environment utilizing sinusoidal inputs, periodic bar patterns and narrow slits. On-orbit sensor MTF estimation was performed on 30-meter GSD Landsat4 Thematic Mapper (TM) data from the bridge pulse target as a pulse input . Because of a high resolution sensor s small Ground Sampling Distance (GSD), reasonably sized man-made edge, pulse, and impulse targets can be deployed on a uniform grassy area with accurate control of ground targets using tarps and convex mirrors. All the previous work cited calculated MTF without testing the MTF estimator's performance. In previous report, a numerical generic sensor model had been developed to simulate and improve the performance of on-orbit MTF estimating techniques. Results from the previous sensor modeling report that have been incorporated into standard MTF estimation work include Fermi edge detection and the newly developed 4th order modified Savitzky-Golay (MSG) interpolation technique. Noise sensitivity had been studied by performing simulations on known noise sources and a sensor model. Extensive investigation was done to characterize multi-resolution ground noise. Finally, angle simulation was tested by using synthetic pulse targets with angles from 2 to 15 degrees, several brightness levels, and different noise levels from both ground targets and imaging system. As a continuing research activity using the developed sensor model, this report was dedicated to MTF estimation via pulse input method characterization using the Fermi edge detection and 4th order MSG interpolation method. The relationship between pulse width and MTF value at Nyquist was studied including error detection and correction schemes. Pulse target angle sensitivity was studied by using synthetic targets angled from 2 to 12 degrees. In this report, from the ground and system noise simulation, a minimum SNR value was suggested for a stable MTF value at Nyquist for the pulse method. Target width error detection and adjustment technique based on a smooth transition of MTF profile is presented, which is specifically applicable only to the pulse method with 3 pixel wide targets.
Genome-wide association mapping of partial resistance to Aphanomyces euteiches in pea.
Desgroux, Aurore; L'Anthoëne, Virginie; Roux-Duparque, Martine; Rivière, Jean-Philippe; Aubert, Grégoire; Tayeh, Nadim; Moussart, Anne; Mangin, Pierre; Vetel, Pierrick; Piriou, Christophe; McGee, Rebecca J; Coyne, Clarice J; Burstin, Judith; Baranger, Alain; Manzanares-Dauleux, Maria; Bourion, Virginie; Pilet-Nayel, Marie-Laure
2016-02-20
Genome-wide association (GWA) mapping has recently emerged as a valuable approach for refining the genetic basis of polygenic resistance to plant diseases, which are increasingly used in integrated strategies for durable crop protection. Aphanomyces euteiches is a soil-borne pathogen of pea and other legumes worldwide, which causes yield-damaging root rot. Linkage mapping studies reported quantitative trait loci (QTL) controlling resistance to A. euteiches in pea. However the confidence intervals (CIs) of these QTL remained large and were often linked to undesirable alleles, which limited their application in breeding. The aim of this study was to use a GWA approach to validate and refine CIs of the previously reported Aphanomyces resistance QTL, as well as identify new resistance loci. A pea-Aphanomyces collection of 175 pea lines, enriched in germplasm derived from previously studied resistant sources, was evaluated for resistance to A. euteiches in field infested nurseries in nine environments and with two strains in climatic chambers. The collection was genotyped using 13,204 SNPs from the recently developed GenoPea Infinium® BeadChip. GWA analysis detected a total of 52 QTL of small size-intervals associated with resistance to A. euteiches, using the recently developed Multi-Locus Mixed Model. The analysis validated six of the seven previously reported main Aphanomyces resistance QTL and detected novel resistance loci. It also provided marker haplotypes at 14 consistent QTL regions associated with increased resistance and highlighted accumulation of favourable haplotypes in the most resistant lines. Previous linkages between resistance alleles and undesired late-flowering alleles for dry pea breeding were mostly confirmed, but the linkage between loci controlling resistance and coloured flowers was broken due to the high resolution of the analysis. A high proportion of the putative candidate genes underlying resistance loci encoded stress-related proteins and others suggested that the QTL are involved in diverse functions. This study provides valuable markers, marker haplotypes and germplasm lines to increase levels of partial resistance to A. euteiches in pea breeding.
Detection of mumps virus genotype H in two previously vaccinated patients from Mexico City.
Del Valle, Alberto; García, Alí A; Barrón, Blanca L
2016-06-01
Infections caused by mumps virus (MuV) have been successfully prevented through vaccination; however, in recent years, an increasing number of mumps outbreaks have been reported within vaccinated populations. In this study, MuV was genotyped for the first time in Mexico. Saliva samples were obtained from two previously vaccinated patients in Mexico City who had developed parotitis. Viral isolation was carried out in Vero cells, and the SH and HN genes were amplified by RT-PCR. Amplicons were sequenced and compared to a set of reference sequences to identify the MuV genotype.
Spine lesion analysis in 3D CT data - Reporting on research progress
NASA Astrophysics Data System (ADS)
Jan, Jiri; Chmelik, Jiri; Jakubicek, Roman; Ourednicek, Petr; Amadori, Elena; Gavelli, Giampaolo
2018-04-01
The contribution describes progress in the long-term project concerning automatic diagnosis of spine bone lesions. There are two difficult problems: segmenting reliably possibly severely deformed vertebrae in the spine and then detect, segment and classify the lesions that are often hardly visible thus making even the medical expert decisions highly uncertain, with a large inter-expert variety. New approaches are described enabling to solve both problems with a success rate acceptable for clinical testing, at the same time speeding up the process substantially compared to the previous stage. The results are compared with previously published achievements.
Korchazhkina, Olga; Yang, Ying
2004-07-05
A previously described method of measurement of malondialdehyde (MDA) in human urine after derivatisation with 2,4-dinitrophenylhydrazine (DNPH) was tested for a possibility of using methyl malondialdehyde (MeMDA) as an internal standard. Despite structural similarity, those compounds were found to produce different yields of derivatisation under the same conditions depending on urine matrix. We conclude, that MeMDA is not suitable as an internal standard for the measurement of MDA in urine under previously reported conditions when DNPH is used as a deriviatising agent.
Full-waveform detection of non-impulsive seismic events based on time-reversal methods
NASA Astrophysics Data System (ADS)
Solano, Ericka Alinne; Hjörleifsdóttir, Vala; Liu, Qinya
2017-12-01
We present a full-waveform detection method for non-impulsive seismic events, based on time-reversal principles. We use the strain Green's tensor as a matched filter, correlating it with continuous observed seismograms, to detect non-impulsive seismic events. We show that this is mathematically equivalent to an adjoint method for detecting earthquakes. We define the detection function, a scalar valued function, which depends on the stacked correlations for a group of stations. Event detections are given by the times at which the amplitude of the detection function exceeds a given value relative to the noise level. The method can make use of the whole seismic waveform or any combination of time-windows with different filters. It is expected to have an advantage compared to traditional detection methods for events that do not produce energetic and impulsive P waves, for example glacial events, landslides, volcanic events and transform-fault earthquakes for events which velocity structure along the path is relatively well known. Furthermore, the method has advantages over empirical Greens functions template matching methods, as it does not depend on records from previously detected events, and therefore is not limited to events occurring in similar regions and with similar focal mechanisms as these events. The method is not specific to any particular way of calculating the synthetic seismograms, and therefore complicated structural models can be used. This is particularly beneficial for intermediate size events that are registered on regional networks, for which the effect of lateral structure on the waveforms can be significant. To demonstrate the feasibility of the method, we apply it to two different areas located along the mid-oceanic ridge system west of Mexico where non-impulsive events have been reported. The first study area is between Clipperton and Siqueiros transform faults (9°N), during the time of two earthquake swarms, occurring in March 2012 and May 2016. The second area of interest is the Gulf of California where two swarms took place during July and September of 2015. We show that we are able to detect previously non-reported, non-impulsive events and recommend that this method be used together with more traditional template matching methods to maximize the number of detected events.
Zuway, Khaled Y; Smith, Jamie P; Foster, Christopher W; Kapur, Nikil; Banks, Craig E; Sutcliffe, Oliver B
2015-09-21
The global increase in the production and abuse of cathinone-derived New Psychoactive Substances (NPSs) has developed the requirement for rapid, selective and sensitive protocols for their separation and detection. Electrochemical sensing of these compounds has been demonstrated to be an effective method for the in-field detection of these substances, either in their pure form or in the presence of common adulterants, however, the technique is limited in its ability to discriminate between structurally related cathinone-derivatives (for example: (±)-4′-methylmethcathinone (4-MMC, 2a) and (±)-4′-methyl-N-ethylmethcathinone (4-MEC, 2b) when they are both present in a mixture. In this paper we demonstrate, for the first time, the combination of HPLC-UV with amperometric detection (HPLC-AD) for the qualitative and quantitative analysis of 4-MMC and 4-MEC using either a commercially available impinging jet (LC-FC-A) or custom-made iCell channel (LC-FC-B) flow-cell system incorporating embedded graphite screen-printed macroelectrodes. The protocol offers a cost-effective, reproducible and reliable sensor platform for the simultaneous HPLC-UV and amperometric detection of the target analytes. The two systems have similar limits of detection, in terms of amperometric detection [LC-FC-A: 14.66 μg mL(-1) (2a) and 9.35 μg mL(-1) (2b); LC-FC-B: 57.92 μg mL(-1) (2a) and 26.91 μg mL(-1) (2b)], to the previously reported oxidative electrochemical protocol [39.8 μg mL(-1) (2a) and 84.2 μg mL(-1) (2b)], for two synthetic cathinones, prevalent on the recreational drugs market. Though not as sensitive as standard HPLC-UV detection, both flow cells show a good agreement, between the quantitative electroanalytical data, thereby making them suitable for the detection and quantification of 4-MMC and 4-MEC, either in their pure form or within complex mixtures. Additionally, the simultaneous HPLC-UV and amperometric detection protocol detailed herein shows a marked improvement and advantage over previously reported electroanalytical methods, which were either unable to selectively discriminate between structurally related synthetic cathinones (e.g. 4-MMC and 4-MEC) or utilised harmful and restrictive materials in their design.
ERIC Educational Resources Information Center
Monahan, Patrick O.; McHorney, Colleen A.; Stump, Timothy E.; Perkins, Anthony J.
2007-01-01
Previous methodological and applied studies that used binary logistic regression (LR) for detection of differential item functioning (DIF) in dichotomously scored items either did not report an effect size or did not employ several useful measures of DIF magnitude derived from the LR model. Equations are provided for these effect size indices.…
Orbital Metastasis: Rare Initial Presentation of an Occult Gall Bladder Carcinoma.
Jain, Tarun Kumar; Parihar, Ashwin Singh; Sood, Ashwani; Basher, Rajender Kumar; Bollampally, Neeraja; Shekhawat, Amit Singh; Mittal, Bhagwant Rai
2018-03-01
Orbital metastases are known to arise from primary breast carcinoma followed by prostate, malignant melanoma, and lung carcinoma. We report a case of orbital metastasis as the initial presentation of an occult primary gall bladder carcinoma. The FDG PET/CT helped in localizing the occult distant primary site, which previously escaped detection, and also enabled the evaluation of orbital metastasis.
Study of the $$\\beta $$ Decay of Fission Products with the DTAS Detector
Guadilla, V.; Algora, A.; Tain, J. L.; ...
2017-01-01
Total Absorption Spectroscopy measurements of the β decay of 103Mo and 103Tc, important contributors to the decay heat summation calculation in reactors, are reported in this work. Furthermore, the analysis of the experiment, performed at IGISOL with the new DTAS detector, show new β intensity that was not detected in previous measurements with Ge detectors.
A Search for Rapidly Pulsating Hot Subdwarf Stars in the GALEX Survey
NASA Astrophysics Data System (ADS)
Boudreaux, Thomas M.; Barlow, Brad N.; Fleming, Scott W.; Vasquez Soto, Alan; Million, Chase; Reichart, Dan E.; Haislip, Josh B.; Linder, Tyler R.; Moore, Justin P.
2017-08-01
NASA’s Galaxy Evolution Explorer (GALEX) provided near- and far-UV observations for approximately 77% of the sky over a 10-year period; however, the data reduction pipeline initially only released single NUV and FUV images to the community. The recently released Python module gPhoton changes this, allowing calibrated time-series aperture photometry to be extracted easily from the raw GALEX data set. Here we use gPhoton to generate light curves for all hot subdwarf B (sdB) stars that were observed by GALEX, with the intention of identifying short-period, p-mode pulsations. We find that the spacecraft’s short visit durations, uneven gaps between visits, and dither pattern make the detection of hot subdwarf pulsations difficult. Nonetheless, we detect UV variations in four previously known pulsating targets and report their UV pulsation amplitudes and frequencies. Additionally, we find that several other sdB targets not previously known to vary show promising signals in their periodograms. Using optical follow-up photometry with the Skynet Robotic Telescope Network, we confirm p-mode pulsations in one of these targets, LAMOST J082517.99+113106.3, and report it as the most recent addition to the sdBV r class of variable stars.
Serine proteases in rodent hippocampus.
Davies, B J; Pickard, B S; Steel, M; Morris, R G; Lathe, R
1998-09-04
Brain serine proteases are implicated in developmental processes, synaptic plasticity, and in disorders including Alzheimer's disease. The spectrum of the major enzymes expressed in brain has not been established previously. We now present a systematic study of the serine proteases expressed in adult rat and mouse hippocampus. Using a combination of techniques including polymerase chain reaction amplification and Northern blotting we show that tissue-type plasminogen activator (t-PA) is the major species represented. Unexpectedly, the next most abundant species were RNK-Met-1, a lymphocyte protease not reported previously in brain, and two new family members, BSP1 (brain serine protease 1) and BSP2. We report full-length sequences of the two new proteases; homologies indicate that these are of tryptic specificity. Although BSP2 is expressed in several brain regions, BSP1 expression is strikingly restricted to hippocampus. Other enzymes represented, but at lower levels, included elastase IV, proteinase 3, complement C2, chymotrypsin B, chymotrypsin-like protein, and Hageman factor. Although thrombin and urokinase-type plasminogen activator were not detected in the primary screen, low level expression was confirmed using specific polymerase chain reaction primers. In contrast, and despite robust expression of t-PA, the usual t-PA substrate plasminogen was not expressed at detectable levels.
Code of Federal Regulations, 2010 CFR
2010-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... previously approved fire detection and alarm system on a deepwater port? 149.421 Section 149.421 Navigation... Requirements § 149.421 What is the requirement for a previously approved fire detection and alarm system on a deepwater port? An existing fire detection and alarm system on a deepwater port need not meet the...
Woodman, Geoffrey F.; Vogel, Edward K.; Luck, Steven J.
2012-01-01
Many recent studies of visual working memory have used change-detection tasks in which subjects view sequential displays and are asked to report whether they are identical or if one object has changed. A key question is whether the memory system used to perform this task is sufficiently flexible to detect changes in object identity independent of spatial transformations, but previous research has yielded contradictory results. To address this issue, the present study compared standard change-detection tasks with tasks in which the objects varied in size or position between successive arrays. Performance was nearly identical across the standard and transformed tasks unless the task implicitly encouraged spatial encoding. These results resolve the discrepancies in prior studies and demonstrate that the visual working memory system can detect changes in object identity across spatial transformations. PMID:22287933
Falls event detection using triaxial accelerometry and barometric pressure measurement.
Bianchi, Federico; Redmond, Stephen J; Narayanan, Michael R; Cerutti, Sergio; Celler, Branko G; Lovell, Nigel H
2009-01-01
A falls detection system, employing a Bluetooth-based wearable device, containing a triaxial accelerometer and a barometric pressure sensor, is described. The aim of this study is to evaluate the use of barometric pressure measurement, as a surrogate measure of altitude, to augment previously reported accelerometry-based falls detection algorithms. The accelerometry and barometric pressure signals obtained from the waist-mounted device are analyzed by a signal processing and classification algorithm to discriminate falls from activities of daily living. This falls detection algorithm has been compared to two existing algorithms which utilize accelerometry signals alone. A set of laboratory-based simulated falls, along with other tasks associated with activities of daily living (16 tests) were performed by 15 healthy volunteers (9 male and 6 female; age: 23.7 +/- 2.9 years; height: 1.74 +/- 0.11 m). The algorithm incorporating pressure information detected falls with the highest sensitivity (97.8%) and the highest specificity (96.7%).
NASA Astrophysics Data System (ADS)
Shimura, Akihiko; Yanagi, Kazuhiro; Yoshizawa, Masayuki
2018-01-01
In time-resolved pump-probe spectroscopy of carbon nanotubes, the fundamental understanding of the optical generation and detection processes of radial-breathing-mode (RBM) phonons has been inconsistent among the previous reports. In this study, the tunable-pumping/broadband-probing scheme was used to fully reveal the amplitude and phase of the phonon-modulated signals. We observed that signals detected off resonantly to excitonic transitions are delayed by π /2 radians with respect to resonantly detected signals, which demonstrates that RBM phonons are detected through dynamically modulating the linear response, not through adiabatically modulating the light absorption. Furthermore, we found that the initial phases are independent of the pump detuning across the first (E11) and the second (E22) excitonic resonances, evidencing that the RBM phonons are generated by the displacive excitation rather than stimulated Raman process.
Detection of forced oscillations in power systems with multichannel methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Follum, James D.
2015-09-30
The increasing availability of high fidelity, geographically dispersed measurements in power systems improves the ability of researchers and engineers to study dynamic behaviors in the grid. One such behavior that is garnering increased attention is the presence of forced oscillations. Power system engineers are interested in forced oscillations because they are often symptomatic of the malfunction or misoperation of equipment. Though the resulting oscillation is not always large in amplitude, the root cause may be serious. In this report, multi-channel forced oscillation detection methods are developed. These methods leverage previously developed detection approaches based on the periodogram and spectral-coherence. Makingmore » use of geographically distributed channels of data is shown to improved detection performance and shorten the delay before an oscillation can be detected in the online environment. Results from simulated and measured power system data are presented.« less
MOF-Bacteriophage Biosensor for Highly Sensitive and Specific Detection of Staphylococcus aureus.
Bhardwaj, Neha; Bhardwaj, Sanjeev K; Mehta, Jyotsana; Kim, Ki-Hyun; Deep, Akash
2017-10-04
To produce a sensitive and specific biosensor for Staphylococcus aureus, bacteriophages have been interfaced with a water-dispersible and environmentally stable metal-organic framework (MOF), NH 2 -MIL-53(Fe). The conjugation of the MOF with bacteriophages has been achieved through the use of glutaraldehyde as cross-linker. Highly sensitive detection of S. aureus in both synthetic and real samples was realized by the proposed MOF-bacteriophage biosensor based on the photoluminescence quenching phenomena: limit of detection (31 CFU/mL) and range of detection (40 to 4 × 10 8 CFU/mL). This is the first report exploiting the use of an MOF-bacteriophage complex for the biosensing of S. aureus. The results of our study highlight that the proposed biosensor is more sensitive than most of the previous methods while exhibiting some advanced features like specificity, regenerability, extended range of linear detection, and stability for long-term storage (even at room temperature).
Mari, Montse; Nadal, Martí; Schuhmacher, Marta; Barbería, Eneko; García, Francisco; Domingo, José L
2014-06-01
The concentrations of a number of metals were determined in the brain, bone, kidney, liver, and lung of 20 autopsied subjects who had lived, at least 10 years, in the neighborhood of a hazardous waste incinerator (HWI) in Tarragona (Catalonia, Spain). Results were compared with those obtained in 1998 (baseline survey) and previous surveys (2003 and 2007). Arsenic, Be, Ni, Tl, and V showed concentrations below the corresponding detection limits in all tissues. Cadmium showed the highest levels in the kidney, with a mean value of 21.15 μg/g. However, Cd was found below the detection limit in the brain and bone. Chromium showed similar concentrations in the kidney, brain, and lung (range of mean values, 0.57-0.66 μg/g) and higher in the bone (1.38 μg/g). In turn, Hg was below the detection limit in all tissues with the exception of the kidney, where the mean concentration was 0.15 μg/g (range, <0.05-0.58 μg/g). On the other hand, Mn could be detected in all tissues showing the highest levels in the liver and kidney (1.45 and 1.09 μg/g, respectively). Moreover, Pb showed the highest concentrations in bone (mean, 1.39 μg/g; range, <0.025-4.88 μg/g). Finally, Sn could be detected only in some tissue samples, reaching the highest values in the bone (0.17 μg/g). The current metal levels in human tissues from individuals living near the HWI of Tarragona are comparable and of a similar magnitude to previously reported results corresponding to general populations, as well as those of our previous surveys.
Wang, Bronwen; Mueller, Seth; Stetson, Sarah; Bailey, Elizabeth; Lee, Greg
2006-01-01
We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project 'Geologic and Mineral Deposit Data for Alaskan Economic Development.' Data presented here are from samples collected in June and July of 2005. The data are being released at this time with minimal interpretation. This is the second release of aqueous geochemical data from this project; 2004 aqueous geochemical data were published previously (Wang and others, 2006). The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO3-), though in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. In general, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. With the exception of a total mercury concentration of 0.33 ng/L detected in a field blank, field blank major-ion and trace-elements concentrations were below detection.
Search for chameleon particles via photon regeneration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chou, Aaron S.; /CCPP, New York U.
2008-09-01
We report the first results from the GammeV search for chameleon particles, which may be created via photon-photon interactions within a strong magnetic field. The chameleons are assumed to have matter effects sufficiently strong that they reflect from all solid surfaces of the apparatus, thus evading detection in our previous search for weakly-interacting axion-like particles. We implement a novel technique to create and trap the reflective particles within a jar and to detect them later via their afterglow as they slowly convert back into photons. These measurements provide the first experimental constraints on the couplings of chameleons to photons.
mecC-Harboring Methicillin-Resistant Staphylococcus aureus: Hiding in Plain Sight.
Ford, Bradley A
2018-01-01
Previously there was scant data on the performance of laboratory testing to detect mecC -mediated beta-lactam resistance in Staphylococcus aureus Kriegeskorte and colleagues (J Clin Microbiol 56:e00826-17, 2018, https://doi.org/10.1128/JCM.00826-17) report the performance of various clinical tests for the detection of mecC -harboring methicillin-resistant S. aureus (MRSA), which failed to identify from 0 to 41% of tested mecC -harboring MRSA isolates. Changes in practice and new test development are necessary to address the challenge of mecC -harboring MRSA. Copyright © 2017 American Society for Microbiology.
Mechanical control of Renilla luciferase.
Tseng, Chiao-Yu; Zocchi, Giovanni
2013-08-14
We report experiments where the activity of the enzyme luciferase from Renilla reniformis is controlled through a DNA spring attached to the enzyme. In the wake of previous work on kinases, these results establish that mechanical stress applied through the DNA springs is indeed a general method for the artificial control of enzymes, and for the quantitative study of mechano-chemical coupling in these molecules. We also show proof of concept of the luciferase construct as a sensitive molecular probe, detecting a specific DNA target sequence in an easy, one-step, homogeneous assay, as well as SNP detection without melting curve analysis.
Breast Reference Set Application: Chris Li-FHCRC (2014) — EDRN Public Portal
This application proposes to use Reference Set #1. We request access to serum samples collected at the time of breast biopsy from subjects with IC (n=30) or benign disease without atypia (n=30). Statistical power: With 30 BC cases and 30 normal controls, a 25% difference in mean metabolite levels can be detected between groups with 80% power and α=0.05, assuming coefficients of variation of 30%, consistent with our past studies. These sample sizes appear sufficient to enable detection of changes similar in magnitude to those previously reported in pre-clinical (BC recurrence) specimens (20).
CUDA-based real time surgery simulation.
Liu, Youquan; De, Suvranu
2008-01-01
In this paper we present a general software platform that enables real time surgery simulation on the newly available compute unified device architecture (CUDA)from NVIDIA. CUDA-enabled GPUs harness the power of 128 processors which allow data parallel computations. Compared to the previous GPGPU, it is significantly more flexible with a C language interface. We report implementation of both collision detection and consequent deformation computation algorithms. Our test results indicate that the CUDA enables a twenty times speedup for collision detection and about fifteen times speedup for deformation computation on an Intel Core 2 Quad 2.66 GHz machine with GeForce 8800 GTX.
Fluorescent triplex-forming DNA oligonucleotides labeled with a thiazole orange dimer unit
Ikeda, Shuji; Yanagisawa, Hiroyuki; Yuki, Mizue; Okamoto, Akimitsu
2013-01-01
Fluorescent probes for the detection of a double-stranded DNA were prepared by labeling a triplex-forming DNA oligonucleotide with a thiazole orange (TO) dimer unit. They belong to ECHO (exciton-controlled hybridization-sensitive fluorescent oligonucleotide) probes which we have previously reported. The excitonic interaction between the two TO molecules was expected to effectively suppress the background fluorescence of the probes. The applicability of the ECHO probes for the detection of double-stranded DNA was confirmed by examining the thermal stability and photophysical and kinetic properties of the DNA triplexes formed by the ECHO probes. PMID:23445822
False recognition of facial expressions of emotion: causes and implications.
Fernández-Dols, José-Miguel; Carrera, Pilar; Barchard, Kimberly A; Gacitua, Marta
2008-08-01
This article examines the importance of semantic processes in the recognition of emotional expressions, through a series of three studies on false recognition. The first study found a high frequency of false recognition of prototypical expressions of emotion when participants viewed slides and video clips of nonprototypical fearful and happy expressions. The second study tested whether semantic processes caused false recognition. The authors found that participants made significantly higher error rates when asked to detect expressions that corresponded to semantic labels than when asked to detect visual stimuli. Finally, given that previous research reported that false memories are less prevalent in younger children, the third study tested whether false recognition of prototypical expressions increased with age. The authors found that 67% of eight- to nine-year-old children reported nonpresent prototypical expressions of fear in a fearful context, but only 40% of 6- to 7-year-old children did so. Taken together, these three studies demonstrate the importance of semantic processes in the detection and categorization of prototypical emotional expressions.
Blanchard, Philippe; Schurr, Frank; Celle, Olivier; Cougoule, Nicolas; Drajnudel, Patrick; Thiéry, Richard; Faucon, Jean-Paul; Ribière, Magali
2008-11-01
Bee samples were collected in French apiaries that displayed severe losses and mortality during the winter (from November 2007 to March 2008). They were screened for the presence of Israeli acute paralysis virus (IAPV) by using RT-PCR. Five out of 35 surveyed apiaries, located in two different geographical areas, were found positive. This represents the first reported detection of IAPV in France. The specificity of the PCR products was checked by sequencing. The phylogenetic analysis showed that French isolates of IAPV were closely related to a cluster including American and Australian isolates. Nevertheless, most of American isolates previously reported to be associated to Colony Collapse Disorder (CCD) and an Israeli isolate first isolated in 2004 from dead bees were included in another cluster. Since IAPV was detected in only 14% of the affected apiaries, it was not possible to establish a causal link between IAPV and the severe winter losses that occurred.
Mode-mismatched confocal thermal-lens microscope with collimated probe beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cabrera, Humberto, E-mail: hcabrera@ictp.it; Centro Multidisciplinartio de Ciencias, Instituto Venezolano de Investigaciones Científicas; Korte, Dorota
2015-05-15
We report a thermal lens microscope (TLM) based on an optimized mode-mismatched configuration. It takes advantage of the coaxial counter propagating tightly focused excitation and collimated probe beams, instead of both focused at the sample, as it is in currently known TLM setups. A simple mathematical model that takes into account the main features of the instrument is presented. The confocal detection scheme and the introduction of highly collimated probe beam allow enhancing the versatility, limit of detection (LOD), and sensitivity of the instrument. The theory is experimentally verified measuring ethanol’s absorption coefficient at 532.8 nm. Additionally, the presented techniquemore » is applied for detection of ultra-trace amounts of Cr(III) in liquid solution. The achieved LOD is 1.3 ppb, which represents 20-fold enhancement compared to transmission mode spectrometric techniques and a 7.5-fold improvement compared to previously reported methods for Cr(III) based on thermal lens effect.« less
NASA Astrophysics Data System (ADS)
Kuassivi; Bonanno, A.; Ferlet, R.
2005-11-01
We report the detection of pulsations in the far ultraviolet (FUV) light curves of PG 1219+534, PG 1605+072 and PG 1613+426 obtained with the Far Ultraviolet Spectroscopic Explorer (FUSE) in time tagged mode (TTAG). Exposures of the order of a few ksec were sufficient to observe the main frequencies of PG 1219+534 and PG 1605+072 and confirm the detection of a pulsation mode at the surface of PG 1613+426 as reported from ground. For the first time we derive time resolved spectroscopic FUSE data of a sdB pulsator (PG 1605+072) and comment on its line profile variation diagram (lpv diagram). We observe the phase shift between the maximum luminosity and the maximum radius to be consistent with the model of an adiabatic pulsator. We also present evidence that the line broadening previously reported is not caused by rotation but is rather an observational bias due to the rapid Doppler shift of the lines with 17 km s-1 amplitude. Thus our observations do not support the previous claim that PG 1605+072 is (or will evolve into) an unusually fast rotating degenerate dwarf. These results demonstrate the asteroseismological potential of the FUSE satellite which should be viewed as another powerful means of investigating stellar pulsations, along with the MOST and COROT missions.
NASA Astrophysics Data System (ADS)
Yu, Gui-Feng; Yan, Xu; Yu, Miao; Jia, Meng-Yang; Pan, Wei; He, Xiao-Xiao; Han, Wen-Peng; Zhang, Zhi-Ming; Yu, Liang-Min; Long, Yun-Ze
2016-01-01
A facile fabrication strategy via electrospinning and followed by in situ polymerization to fabricate a patterned, highly stretchable, and conductive polyaniline/poly(vinylidene fluoride) (PANI/PVDF) nanofibrous membrane is reported. Owing to the patterned structure, the nanofibrous PANI/PVDF strain sensor can detect a strain up to 110%, for comparison, which is 2.6 times higher than the common nonwoven PANI/PVDF mat and much larger than the previously reported values (usually less than 15%). Meanwhile, the conductivity of the patterned strain sensor shows a linear response to the applied strain in a wide range from 0% to about 85%. Additionally, the patterned PANI/PVDF strain sensor can completely recover to its original electrical and mechanical values within a strain range of more than 22%, and exhibits good durability over 10 000 folding-unfolding tests. Furthermore, the strain sensor also can be used to detect finger motion. The results demonstrate promising application of the patterned nanofibrous membrane in flexible electronic fields.A facile fabrication strategy via electrospinning and followed by in situ polymerization to fabricate a patterned, highly stretchable, and conductive polyaniline/poly(vinylidene fluoride) (PANI/PVDF) nanofibrous membrane is reported. Owing to the patterned structure, the nanofibrous PANI/PVDF strain sensor can detect a strain up to 110%, for comparison, which is 2.6 times higher than the common nonwoven PANI/PVDF mat and much larger than the previously reported values (usually less than 15%). Meanwhile, the conductivity of the patterned strain sensor shows a linear response to the applied strain in a wide range from 0% to about 85%. Additionally, the patterned PANI/PVDF strain sensor can completely recover to its original electrical and mechanical values within a strain range of more than 22%, and exhibits good durability over 10 000 folding-unfolding tests. Furthermore, the strain sensor also can be used to detect finger motion. The results demonstrate promising application of the patterned nanofibrous membrane in flexible electronic fields. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08618c
Christensen, Søren Troels; Bjerrum, Ole Jannik
2013-12-01
Postmarketing studies of drugs forms an essential part of safety surveillance. In particular, this concerns new drugs as safety information of these by large rests on randomized clinical studies conducted on a limited number of subjects before licensing. Pharmacists in community pharmacies are in a unique position for detection of user experienced adverse drug reactions (ADRs) in relation to drug dispensing. The study reports from a research initiative exploring prompt and proactive ADR detection of liraglutide and reporting facilitated by pharmacy students undertaking internship in a community pharmacy in Denmark. Nineteen pharmacy students undertaking regular 6 months' internship--eighth semester--in a Danish community pharmacy participated in the data collection. Before the data collection, students attended an interactive training seminar addressing ADRs in general, organ symptoms, diagnostic classification, and pharmacovigilance systems. Pharmacy students approached recurrent drug users purchasing liraglutide. Participating users were asked about experienced ADRs linked to liraglutide use. Reported ADRs were collected and analyzed. Sixty-two liraglutide users participated in the study, of whom, 38 reported 84 ADRs possibly linked to liraglutide usage. Nausea was by far the most reported ADR followed by decreased appetite, diarrhea, fatigue, and abdominal pain (upper). The reported ADRs are in accordance with previously reported ADRs. The study has demonstrated the feasibility of community pharmacy driven pharmacovigilance. The study supports the thesis that community pharmacists in the future may play a proactive and prominent role in patient-centered pharmacovigilance.
Effect of the GPI anchor of human Thy-1 on antibody recognition and function
Bradley, John E.; Chan, Joy M.; Hagood, James S.
2012-01-01
Thymocyte differentiation antigen 1 (Thy-1) is a glycosylphosphatidyl inositol (GPI)-linked cell surface glycoprotein expressed on numerous cell types, which regulates signals affecting cell adhesion, migration, differentiation, and survival. In addition, Thy-1 has been detected in serum, cerebral spinal fluid, wound fluid from venous ulcers, synovial fluid from joints in rheumatoid arthritis and more recently urine. We previously detected Thy-1 in the conditioned media of cytokine-stimulated lung fibroblasts, suggesting that Thy-1 shedding may be a response to cellular stress. Soluble and membrane bound forms of Thy-1 from in vivo sources have been shown to be identical in size when deglycosylated, suggesting that soluble Thy-1 is separated from the diacyl glycerol portion of its GPI-anchor by hydrolysis within the GPI moiety. For Thy-1 and other GPI-anchored proteins, delipidation induces a stable change in conformation that manifests itself in a change in antibody affinity for soluble forms. Using epitope tagged recombinant soluble Thy-1, we report that widely available monoclonal antibodies to human Thy-1 are unable to detect soluble Thy-1 by immunoblotting. We reevaluated the Thy-1 that we previously reported in the conditioned media of normal human lung fibroblasts and found it to be entirely insoluble. These findings suggest that most Thy-1 reported in body fluids retains its GPI anchor and may be associated with membrane fragments or vesicles. This phenomenon should be considered in the generation of antibodies and controls for Thy-1 bioassays. Furthermore, the changes in Thy-1 conformation with delipidation, beyond affecting antibody affinity, likely affect the ligand affinity and biological function of soluble vs. released membrane-associated forms. PMID:23358110
Wang, Bronwen; Mueller, Seth; Stetson, Sarah; Bailey, Elizabeth; Lee, Greg
2011-01-01
We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle, Alaska. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project entitled ?Geologic and Mineral Deposit Data for Alaskan Economic Development.? Data presented here are from samples collected in June and July 2006. The data are being released at this time with minimal interpretation. This is the third release of aqueous geochemical data from this project; aqueous geochemical data from samples collected in 2004 and 2005 were published previously. The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountains quadrangle is dominated by bicarbonate (HCO3-), although in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. Generally, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. All field blank major-ion and trace-element concentrations were below detection.
Fukui, Daisuke; Nakamura, Makiko; Yamaguchi, Tsuyoshi; Takenaka, Makiko; Murakami, Mami; Yanai, Tokuma; Fukushi, Hideto; Yanagida, Kazumi; Bando, Gen; Matsuno, Keita; Nagano, Masashi; Tsubota, Toshio
2016-04-28
In 2006-10, an epizootic of emerging avian pox occurred in Carrion Crows ( Corvus corone ) and Large-billed Crows ( Corvus macrorhynchos ), leading to mortality of juvenile crows in Hokkaido, the northernmost island of Japan. We diagnosed 27 crows with proliferative skin lesions (19 carcasses and eight biopsied cases [one in zoo captivity]) as avian pox clinically, histopathologically by detection of Avipoxvirus-specific 4b core protein (P4b) gene, and epidemiologically. The fatal cases demonstrated intensively severe infection and aggressive lesions with secondary bacterial infection. Since the first identification of avian pox in Sapporo, Japan, in 2006, the frequency of mortality events has increased, peaking in 2007-08. Mortalities have subsequently occurred in other areas, suggesting disease expansion. In Sapporo, prevalence of avian pox evaluated by field censuses during 2007-12 was 17.6% (6.6-27.2%), peaked during 2007-08 and 2008-09, and then decreased. All diseased crows were juveniles, except for one adult. The number of crows assembling in the winter roosts had been stable for >10 yr; however, it declined in 2007-08, decreased by about 50% in 2008-09, and recovered to the previous level in 2009-10, correlated with the avian pox outbreak. Thus, avian pox probably contributed to the unusual crow population decline. All P4b sequences detected in six specimens in Sapporo were identical and different from any previously reported sequences. The sequence detected in the zoo-kept crow was distinct from any reported clades, and interspecies transmission was suspected. This report demonstrates an emerging novel avian pox in the Japanese avifauna and in global populations of Carrion Crows and Large-billed Crows. Longitudinal monitoring is needed to evaluate its impact on the crow population.
Tomar, Swati; Sethi, Raman; Sundar, Gangadhara; Quah, Thuan Chong; Quah, Boon Long; Lai, Poh San
2017-01-01
Retinoblastoma (RB) is a rare childhood malignant disorder caused by the biallelic inactivation of RB1 gene. Early diagnosis and identification of carriers of heritable RB1 mutations can improve disease outcome and management. In this study, mutational analysis was conducted on fifty-nine matched tumor and peripheral blood samples from 18 bilateral and 41 unilateral unrelated RB cases by a combinatorial approach of Multiplex Ligation-dependent Probe Amplification (MLPA) assay, deletion screening, direct sequencing, copy number gene dosage analysis and methylation assays. Screening of both blood and tumor samples yielded a mutation detection rate of 94.9% (56/59) while only 42.4% (25/59) of mutations were detected if blood samples alone were analyzed. Biallelic mutations were observed in 43/59 (72.9%) of tumors screened. There were 3 cases (5.1%) in which no mutations could be detected and germline mutations were detected in 19.5% (8/41) of unilateral cases. A total of 61 point mutations were identified, of which 10 were novel. There was a high incidence of previously reported recurrent mutations, occurring at 38.98% (23/59) of all cases. Of interest were three cases of mosaic RB1 mutations detected in the blood from patients with unilateral retinoblastoma. Additionally, two germline mutations previously reported to be associated with low-penetrance phenotypes: missense-c.1981C>T and splice variant-c.607+1G>T, were observed in a bilateral and a unilateral proband, respectively. These findings have implications for genetic counselling and risk prediction for the affected families. This is the first published report on the spectrum of mutations in RB patients from Singapore and shows that further improved mutation screening strategies are required in order to provide a definitive molecular diagnosis for every case of RB. Our findings also underscore the importance of genetic testing in supporting individualized disease management plans for patients and asymptomatic family members carrying low-penetrance, germline mosaicism or heritable unilateral mutational phenotypes. PMID:28575107
Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Fu, Tao Qi Huang; Fernandez, Charlene Judith; Gildea, Sarah; Cullinane, Ann
2017-06-16
Equine influenza (EI) is a respiratory disease caused by equine influenza A virus (EIV, H3N8) infection. Rapid diagnosis is essential to limit the disease spread. We previously reported that some rapid antigen detection (RAD) tests are fit for diagnosing EI although their sensitivity is not optimal. Here, we evaluated the performance of the newly developed RAD test using silver amplification immunochromatography (Quick Chaser Auto Flu A, B: QCA) to diagnose EI. The detection limits of QCA for EIVs were five-fold lower than the conventional RAD tests. The duration of virus antigen detection in the infected horses was longer than the conventional RAD tests. We conclude that QCA could be a valuable diagnostic method for EI.
Detection of 16 gamma-ray pulsars through blind frequency searches using the Fermi LAT.
Abdo, A A; Ackermann, M; Ajello, M; Anderson, B; Atwood, W B; Axelsson, M; Baldini, L; Ballet, J; Barbiellini, G; Baring, M G; Bastieri, D; Baughman, B M; Bechtol, K; Bellazzini, R; Berenji, B; Bignami, G F; Blandford, R D; Bloom, E D; Bonamente, E; Borgland, A W; Bregeon, J; Brez, A; Brigida, M; Bruel, P; Burnett, T H; Caliandro, G A; Cameron, R A; Caraveo, P A; Casandjian, J M; Cecchi, C; Celik, O; Chekhtman, A; Cheung, C C; Chiang, J; Ciprini, S; Claus, R; Cohen-Tanugi, J; Conrad, J; Cutini, S; Dermer, C D; de Angelis, A; de Luca, A; de Palma, F; Digel, S W; Dormody, M; do Couto e Silva, E; Drell, P S; Dubois, R; Dumora, D; Farnier, C; Favuzzi, C; Fegan, S J; Fukazawa, Y; Funk, S; Fusco, P; Gargano, F; Gasparrini, D; Gehrels, N; Germani, S; Giebels, B; Giglietto, N; Giommi, P; Giordano, F; Glanzman, T; Godfrey, G; Grenier, I A; Grondin, M-H; Grove, J E; Guillemot, L; Guiriec, S; Gwon, C; Hanabata, Y; Harding, A K; Hayashida, M; Hays, E; Hughes, R E; Jóhannesson, G; Johnson, R P; Johnson, T J; Johnson, W N; Kamae, T; Katagiri, H; Kataoka, J; Kawai, N; Kerr, M; Knödlseder, J; Kocian, M L; Kuss, M; Lande, J; Latronico, L; Lemoine-Goumard, M; Longo, F; Loparco, F; Lott, B; Lovellette, M N; Lubrano, P; Madejski, G M; Makeev, A; Marelli, M; Mazziotta, M N; McConville, W; McEnery, J E; Meurer, C; Michelson, P F; Mitthumsiri, W; Mizuno, T; Monte, C; Monzani, M E; Morselli, A; Moskalenko, I V; Murgia, S; Nolan, P L; Norris, J P; Nuss, E; Ohsugi, T; Omodei, N; Orlando, E; Ormes, J F; Paneque, D; Parent, D; Pelassa, V; Pepe, M; Pesce-Rollins, M; Pierbattista, M; Piron, F; Porter, T A; Primack, J R; Rainò, S; Rando, R; Ray, P S; Razzano, M; Rea, N; Reimer, A; Reimer, O; Reposeur, T; Ritz, S; Rochester, L S; Rodriguez, A Y; Romani, R W; Ryde, F; Sadrozinski, H F-W; Sanchez, D; Sander, A; Saz Parkinson, P M; Scargle, J D; Sgrò, C; Siskind, E J; Smith, D A; Smith, P D; Spandre, G; Spinelli, P; Starck, J-L; Strickman, M S; Suson, D J; Tajima, H; Takahashi, H; Takahashi, T; Tanaka, T; Thayer, J G; Thompson, D J; Tibaldo, L; Tibolla, O; Torres, D F; Tosti, G; Tramacere, A; Uchiyama, Y; Usher, T L; Van Etten, A; Vasileiou, V; Vilchez, N; Vitale, V; Waite, A P; Wang, P; Watters, K; Winer, B L; Wolff, M T; Wood, K S; Ylinen, T; Ziegler, M
2009-08-14
Pulsars are rapidly rotating, highly magnetized neutron stars emitting radiation across the electromagnetic spectrum. Although there are more than 1800 known radio pulsars, until recently only seven were observed to pulse in gamma rays, and these were all discovered at other wavelengths. The Fermi Large Area Telescope (LAT) makes it possible to pinpoint neutron stars through their gamma-ray pulsations. We report the detection of 16 gamma-ray pulsars in blind frequency searches using the LAT. Most of these pulsars are coincident with previously unidentified gamma-ray sources, and many are associated with supernova remnants. Direct detection of gamma-ray pulsars enables studies of emission mechanisms, population statistics, and the energetics of pulsar wind nebulae and supernova remnants.
Liu, Benhua; Li, Yuehua; Ma, Jianfeng; Huang, Linxian; Chen, Liang
2016-01-01
China is suffering from serious water and soil pollution, especially in the North China Plain. This work investigated semi-volatile organic compounds (SVOCs) in surface water, groundwater and soil within a chemical industrial park in Eastern China, for which the volatile organic compound (VOC) results have been previously reported. A total of 20 samples were collected from the field, and analyzed in the laboratory. A 100% detection frequency of SVOCs in samples from this chemical industrial park was observed (same as VOCs). Moreover, the detection frequency of 113 SVOCs in each sample reached 15.93, 12.39 and 20.35% for surface water, groundwater and soil, respectively. The most detected SVOCs in the park included N-containing SVOCs, polycyclic aromatic hydrocarbons, phthalates, organic pesticides and polychlorodiphenyls. The elevated detecting frequencies and concentration levels of SVOCs identified in the groundwater were attributed to the intensive chemical production activities in the park. In addition, the agricultural activities in the area might also have contributed to the SVOCs to the groundwater. The results of VOCs and SVOCs from this and previous studies suggest that the groundwater in this industrial park has been severely contaminated, and the contamination likely spreads beyond the park. Imminent hydrogeological assessments and remedial actions are warranted to eliminate the source and mitigate the potential plume expansion beyond the park boundary.
Coldwell, Kate E.; Cutts, Suzanne M.; Ognibene, Ted J.; Henderson, Paul T.; Phillips, Don R.
2008-01-01
Limited sensitivity of existing assays has prevented investigation of whether Adriamycin–DNA adducts are involved in the anti-tumour potential of Adriamycin. Previous detection has achieved a sensitivity of a few Adriamycin–DNA adducts/104 bp DNA, but has required the use of supra-clinical drug concentrations. This work sought to measure Adriamycin–DNA adducts at sub-micromolar doses using accelerator mass spectrometry (AMS), a technique with origins in geochemistry for radiocarbon dating. We have used conditions previously validated (by less sensitive decay counting) to extract [14C]Adriamycin–DNA adducts from cells and adapted the methodology to AMS detection. Here we show the first direct evidence of Adriamycin–DNA adducts at clinically-relevant Adriamycin concentrations. [14C]Adriamycin treatment (25 nM) resulted in 4.4 ± 1.0 adducts/107 bp (∼1300 adducts/cell) in MCF-7 breast cancer cells, representing the best sensitivity and precision reported to date for the covalent binding of Adriamycin to DNA. The exceedingly sensitive nature of AMS has enabled over three orders of magnitude increased sensitivity of Adriamycin–DNA adduct detection and revealed adduct formation within an hour of drug treatment. This method has been shown to be highly reproducible for the measurement of Adriamycin–DNA adducts in tumour cells in culture and can now be applied to the detection of these adducts in human tissues. PMID:18632763
DNA Hypermethylation Patterns Detected in Serum as a Tool for Early Breast Cancer Diagnosis
2008-09-01
age at, and date of, blood donation. The analysis of the promoter methylation status of a panel of six cancer- related genes (RASSF1A, GSTP1 , RARβ2...Gene Selection: As reported in the previous progress report, the gene panel was modified to include: RASSF1A, HIN-1, GSTP1 , APC, p16 and RARβ2...gene was removed from the panel (for the time being) and analysis of RASSF1A, GSTP1 , RARβ2 and APC conducted. QMSP Results: Assays have been
Yang, Kamie K; Lewis, Ian H
2014-06-15
Various equipment malfunctions of anesthesia gas delivery systems have been previously reported. Our profession increasingly uses technology as a means to prevent these errors. We report a case of a near-total anesthesia circuit obstruction that went undetected before the induction of anesthesia despite the use of automated machine check technology. This case highlights that automated machine check modules can fail to detect severe equipment failure and demonstrates how, even in this era of expanding technology, manual checks still remain essential components of safe care.
Radionuclide demonstration of urinary extravasation with ureteral obstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, V.A.; Chiang, L.C.; Meade, R.C.
Two cases of urinary extravasation with ureteral obstruction demonstrated by the radionuclide studies are reported. The value of radionuclide studies in patients with renal transplantation has been reported previously, but studies in patients without transplantation have rarely been described in the literature. Ureteral obstruction may cause urinary extravasation, which may be demonstrated by radionuclide studies even when radiologic studies are inconclusive. In one case, urinary extravasation was detected in the sitting position but not in the supine position. Renal imaging should probably be performed not only with multiple projections but also in different positions.
A critical incident report: Propofol triggered anaphylaxis
Koul, Archna; Jain, Rashmi; Sood, Jayashree
2011-01-01
Although propofol is one of the most commonly used drugs for induction of anaesthesia, it is not devoid of anaphylactic potential. Early detection of any suspected anaphylactic reaction during anaesthesia, prompt management, identification of the offending agent and prevention of exposure to the offending agent in the future is the responsibility of the anaesthesiologist. This is a case report of anaphylaxis to propofol at the induction of anaesthesia in a previously non-allergic 56 year-old man, planned to undergo laparoscopic nephrectomy, who responded to epinephrine infusion. PMID:22174476
Statistical significance of the rich-club phenomenon in complex networks
NASA Astrophysics Data System (ADS)
Jiang, Zhi-Qiang; Zhou, Wei-Xing
2008-04-01
We propose that the rich-club phenomenon in complex networks should be defined in the spirit of bootstrapping, in which a null model is adopted to assess the statistical significance of the rich-club detected. Our method can serve as a definition of the rich-club phenomenon and is applied to analyze three real networks and three model networks. The results show significant improvement compared with previously reported results. We report a dilemma with an exceptional example, showing that there does not exist an omnipotent definition for the rich-club phenomenon.
Gynephilic Men's Self-Reported and Genital Sexual Responses to Relationship Context Cues.
Timmers, Amanda D; Chivers, Meredith L
2018-04-01
The current study examined men's sexual responses to relationship context. Chivers and Timmers (2012) previously reported that heterosexual men's genital and self-reported sexual arousal varied by gender but not relationship context, suggesting that gender cues are more salient determinants of sexual response than relationship context cues for men. Those analyses were, however, significantly underpowered to detect relationship context effects (n = 9). The current study utilized the same paradigm as Chivers and Timmers' study, exposing a larger sample of heterosexual men (n = 26) to audio narratives describing sexual interactions that varied by partner gender (man, woman) and relationship context (stranger, friend, long-term relationship), and observing effects on genital and self-reported sexual response. Results indicated that men's genital response to relationship context cues mirrored those previously reported for heterosexual women (Chivers & Timmers, 2012); heterosexual men demonstrated less genital response to the friend than to the stranger or long-term relationship conditions. No significant effect of relationship context was found for men's self-reported sexual arousal. These data suggest that, in addition to gender cues, relationship cues may also be an important determinant of men's genital sexual responses.
Gyberg, Viveca; De Bacquer, Dirk; De Backer, Guy; Jennings, Catriona; Kotseva, Kornelia; Mellbin, Linda; Schnell, Oliver; Tuomilehto, Jaakko; Wood, David; Rydén, Lars; Amouyel, Philippe; Bruthans, Jan; Conde, Almudena Castro; Cifkova, Renata; Deckers, Jaap W; De Sutter, Johan; Dilic, Mirza; Dolzhenko, Maryna; Erglis, Andrejs; Fras, Zlatko; Gaita, Dan; Gotcheva, Nina; Goudevenos, John; Heuschmann, Peter; Laucevicius, Aleksandras; Lehto, Seppo; Lovic, Dragan; Miličić, Davor; Moore, David; Nicolaides, Evagoras; Oganov, Raphael; Pająk, Andrzej; Pogosova, Nana; Reiner, Zeljko; Stagmo, Martin; Störk, Stefan; Tokgözoğlu, Lale; Vulic, Dusko
2015-10-01
In order to influence every day clinical practice professional organisations issue management guidelines. Cross-sectional surveys are used to evaluate the implementation of such guidelines. The present survey investigated screening for glucose perturbations in people with coronary artery disease and compared patients with known and newly detected type 2 diabetes with those without diabetes in terms of their life-style and pharmacological risk factor management in relation to contemporary European guidelines. A total of 6187 patients (18-80 years) with coronary artery disease and known glycaemic status based on a self reported history of diabetes (previously known diabetes) or the results of an oral glucose tolerance test and HbA1c (no diabetes or newly diagnosed diabetes) were investigated in EUROASPIRE IV including patients in 24 European countries 2012-2013. The patients were interviewed and investigated in order to enable a comparison between their actual risk factor control with that recommended in current European management guidelines and the outcome in previously conducted surveys. A total of 2846 (46%) patients had no diabetes, 1158 (19%) newly diagnosed diabetes and 2183 (35%) previously known diabetes. The combined use of all four cardioprotective drugs in these groups was 53, 55 and 60%, respectively. A blood pressure target of <140/90 mmHg was achieved in 68, 61, 54% and a LDL-cholesterol target of <1.8 mmol/L in 16, 18 and 28%. Patients with newly diagnosed and previously known diabetes reached an HbA1c <7.0% (53 mmol/mol) in 95 and 53% and 11% of those with previously known diabetes had an HbA1c >9.0% (>75 mmol/mol). Of the patients with diabetes 69% reported on low physical activity. The proportion of patients participating in cardiac rehabilitation programmes was low (≈40 %) and only 27% of those with diabetes had attended diabetes schools. Compared with data from previous surveys the use of cardioprotective drugs had increased and more patients were achieving the risk factor treatment targets. Despite advances in patient management there is further potential to improve both the detection and management of patients with diabetes and coronary artery disease.
Cheetah paradigm revisited: MHC diversity in the world's largest free-ranging population.
Castro-Prieto, Aines; Wachter, Bettina; Sommer, Simone
2011-04-01
For more than two decades, the cheetah (Acinonyx jubatus) has been considered a paradigm of disease vulnerability associated with low genetic diversity, particularly at the immune genes of the major histocompatibility complex (MHC). Cheetahs have been used as a classic example in numerous conservation genetics textbooks as well as in many related scientific publications. However, earlier studies used methods with low resolution to quantify MHC diversity and/or small sample sizes. Furthermore, high disease susceptibility was reported only for captive cheetahs, whereas free-ranging cheetahs show no signs of infectious diseases and a good general health status. We examined whether the diversity at MHC class I and class II-DRB loci in 149 Namibian cheetahs was higher than previously reported using single-strand conformation polymorphism analysis, cloning, and sequencing. MHC genes were examined at the genomic and transcriptomic levels. We detected ten MHC class I and four class II-DRB alleles, of which nine MHC class I and all class II-DRB alleles were expressed. Phylogenetic analyses and individual genotypes suggested that the alleles belong to four MHC class I and three class II-DRB putative loci. Evidence of positive selection was detected in both MHC loci. Our study indicated that the low number of MHC class I alleles previously observed in cheetahs was due to a smaller sample size examined. On the other hand, the low number of MHC class II-DRB alleles previously observed in cheetahs was further confirmed. Compared with other mammalian species including felids, cheetahs showed low levels of MHC diversity, but this does not seem to influence the immunocompetence of free-ranging cheetahs in Namibia and contradicts the previous conclusion that the cheetah is a paradigm species of disease vulnerability.
Tantisira, J G; Kowalski, R P; Gordon, Y J
1995-07-01
The Kodak Surecell Chlamydia test, a rapid enzyme immunoassay, has been reported to be highly sensitive (93%) and specific (96%) for detecting chlamydial lipopolysaccharide antigen in conjunctival specimens from infants, but has not been evaluated previously in adult conjunctival specimens. This study was designed to determine the efficacy of the Kodak Surecell Chlamydia test for the laboratory diagnosis of adult inclusion conjunctivitis. Twenty Chlamydia culture-positive conjunctival specimens from adults (true-positives) and 20 true-negative specimens were tested with the Kodak Surecell Chlamydia test. The Kodak Surecell Chlamydia test was 40% (8/20) sensitive, 100% (20/20) specific, and 70% (28/40) efficient. This study indicates that the Kodak Surecell Chlamydia test, though highly specific, is less sensitive in its ability to diagnose chlamydial conjunctivitis in adults than has been reported previously in infants.
The Distribution of Interplanetary Dust Near 1-AU: An MMS Perspective
NASA Astrophysics Data System (ADS)
Adrian, M. L.; St Cyr, O. C.; Wilson, L. B., III; Schiff, C.; Sacks, L. W.; Chai, D. J.; Queen, S. Z.; Sedlak, J. E.
2017-12-01
The distribution of dust in the ecliptic plane in the vicinity of 1-AU has been inferred from impacts on the four Magnetospheric Multiscale (MMS) mission spacecraft as detected by the Acceleration Measurement System (AMS) during periods when no other spacecraft activities are in progress. Consisting of four identically instrumented spacecraft, with an inter-spacecraft separation ranging from 10-km to 400-km, the MMS constellation forms a dust "detector" with approximately four-times the collection area of any previous dust monitoring framework. Here we introduce the MMS-AMS and the inferred dust impact observations, provide a preliminary comparison of the MMS distribution of dust impacts to previously reported interplanetary dust distributions — namely those of the STEREO mission — and report on our initial comparison of the MMS distribution of dust impacts with known meteor showers.
Wang, Xuewei; Yue, Dengfeng; Lv, Enguang; Wu, Lei; Qin, Wei
2014-02-18
The tremendous applications of boronic acids (BAs) in chemical sensing, medical chemistry, molecular assembly, and organic synthesis lead to an urgent demand for developing effective sensing methods for BAs. This paper reports a facile and sensitive potentiometric sensor scheme for heterogeneous detection of BAs based on their unexpected potential responses on quaternary ammonium salt-doped polymeric liquid membranes. (11)B NMR data reveal that a quaternary ammonium chloride can trigger the hydrolysis of an electrically neutral BA in an aprotic solvent. Using the quaternary ammonium salt as the receptor, the BA molecules can be extracted from the sample solution into the polymeric membrane phase and undergo the concomitant hydrolysis. Such salt-triggered hydrolysis generates H(+) ions, which can be coejected into the aqueous phase with the counterions (e.g., Cl(-)) owing to their high hydrophilicities. The perturbation on the ionic partition at the sample-membrane interface changes the phase boundary potential and thus enables the potentiometric sensing of BAs. In contrast to other transduction methods for BAs, for which labeled or separate reporters are exclusively required, the present heterogeneous sensing scheme allows the direct detection of BAs without using any reporter molecules. This technique shows superior detection limits for BAs (e.g., 1.0 × 10(-6) M for phenylboronic acid) as compared to previously reported methods based on colorimetry, fluorimetry, and mass spectrometry. The proposed sensing strategy has also been successfully applied to potentiometric indication of the BA reactions with hydrogen peroxide and saccharides, which allows indirect and sensitive detection of these important species.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aab, A.; Abreu, P.; Andringa, S.
2017-06-01
We report a multi-resolution search for anisotropies in the arrival directions of cosmic rays detected at the Pierre Auger Observatory with local zenith angles up to 80{sup o} and energies in excess of 4 EeV (4 × 10{sup 18} eV). This search is conducted by measuring the angular power spectrum and performing a needlet wavelet analysis in two independent energy ranges. Both analyses are complementary since the angular power spectrum achieves a better performance in identifying large-scale patterns while the needlet wavelet analysis, considering the parameters used in this work, presents a higher efficiency in detecting smaller-scale anisotropies, potentially providingmore » directional information on any observed anisotropies. No deviation from isotropy is observed on any angular scale in the energy range between 4 and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured; while no other deviation from isotropy is observed for moments beyond the dipole one. The corresponding p -values obtained after accounting for searches blindly performed at several angular scales, are 1.3 × 10{sup −5} in the case of the angular power spectrum, and 2.5 × 10{sup −3} in the case of the needlet analysis. While these results are consistent with previous reports making use of the same data set, they provide extensions of the previous works through the thorough scans of the angular scales.« less
HIV-1 Viral Escape in Cerebrospinal Fluid of Subjects on Suppressive Antiretroviral Treatment
Edén, Arvid; Fuchs, Dietmar; Hagberg, Lars; Nilsson, Staffan; Spudich, Serena; Svennerholm, Bo; Price, Richard W.; Gisslén, Magnus
2010-01-01
Background. Occasional cases of viral escape in cerebrospinal fluid (CSF) despite suppression of plasma human immunodeficiency virus type 1 (HIV-1) RNA have been reported. We investigated CSF viral escape in subjects treated with commonly used antiretroviral therapy regimens in relation to intrathecal immune activation and central nervous system penetration effectiveness (CPE) rank. Methods. Sixty-nine neurologically asymptomatic subjects treated with antiretroviral therapy >6 months and plasma HIV-1 RNA <50 copies/mL were cross-sectionally included in the analysis. Antiretroviral therapy regimens included efavirenz, lopinavir/ritonavir or atazanavir/ritonavir combined with tenofovir, abacavir, or zidovudine and emtricitabine or lamivudine. HIV-1 RNA was analyzed with real-time polymerase chain reaction assays. Neopterin was analyzed by enzyme-linked immunosorbent assay. Results. Seven (10%) of the 69 subjects had detectable CSF HIV-1 RNA, in median 121 copies/mL (interquartile range, 54–213 copies/mL). Subjects with detectable CSF virus had significantly higher CSF neopterin and longer duration of treatment. Previous treatment interruptions were more common in subjects with CSF escape. Central nervous system penetration effectiveness rank was not a significant predictor of detectable CSF virus or CSF neopterin levels. Conclusions. Viral escape in CSF is more common than previously reported, suggesting that low-grade central nervous system infection may continue in treated patients. Although these findings need extension in longitudinal studies, they suggest the utility of monitoring CSF responses, as new treatment combinations and strategies modify clinical practice. PMID:21050119
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aab, A.; Abreu, P.; Aglietta, M.
We report a multi-resolution search for anisotropies in the arrival directions of cosmic rays detected at the Pierre Auger Observatory with local zenith angles up to 80(o) and energies in excess of 4 EeV (4 × 10 18 eV). This search is conducted by measuring the angular power spectrum and performing a needlet wavelet analysis in two independent energy ranges. Both analyses are complementary since the angular power spectrum achieves a better performance in identifying large-scale patterns while the needlet wavelet analysis, considering the parameters used in this work, presents a higher efficiency in detecting smaller-scale anisotropies, potentially providing directional information onmore » any observed anisotropies. No deviation from isotropy is observed on any angular scale in the energy range between 4 and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured, while no other deviation from isotropy is observed for moments beyond the dipole one. The corresponding p-values obtained after accounting for searches blindly performed at several angular scales, are 1.3 × 10 -5 in the case of the angular power spectrum, and 2.5 × 10 -3 in the case of the needlet analysis. While these results are consistent with previous reports making use of the same data set, they provide extensions of the previous works through the thorough scans of the angular scales.« less
Kodamatani, Hitoshi; Yamasaki, Hitomi; Sakaguchi, Takeru; Itoh, Shinya; Iwaya, Yoshimi; Saga, Makoto; Saito, Keiitsu; Kanzaki, Ryo; Tomiyasu, Takashi
2016-08-19
As a contaminant in drinking water, N-nitrosodimethylamine (NDMA) is of great concern because of its carcinogenicity; it has been limited to levels of ng/L by regulatory bodies worldwide. Consequently, a rapid and sensitive method for monitoring NDMA in drinking water is urgently required. In this study, we report an improvement of our previously proposed HPLC-based system for NDMA determination. The approach consists of the HPLC separation of NDMA, followed by NDMA photolysis to form peroxynitrite and detection with a luminol chemiluminescence reaction. The detection limit for the improved HPLC method was 0.2ng/L, which is 10 times more sensitive than our previously reported system. For tap water measurements, only the addition of an ascorbic acid solution to eliminate residual chlorine and passage through an Oasis MAX solid-phase extraction cartridge are needed. The proposed NDMA determination method requires a sample volume of less than 2mL and a complete analysis time of less than 15min per sample. The method was utilized for the long-term monitoring of NDMA in tap water. The NDMA level measured in the municipal water survey was 4.9ng/L, and a seasonal change of the NDMA concentration in tap water was confirmed. The proposed method should constitute a useful NDMA monitoring method for protecting drinking water quality. Copyright © 2016 Elsevier B.V. All rights reserved.
HIV-1 viral escape in cerebrospinal fluid of subjects on suppressive antiretroviral treatment.
Edén, Arvid; Fuchs, Dietmar; Hagberg, Lars; Nilsson, Staffan; Spudich, Serena; Svennerholm, Bo; Price, Richard W; Gisslén, Magnus
2010-12-15
Occasional cases of viral escape in cerebrospinal fluid (CSF) despite suppression of plasma human immunodeficiency virus type 1 (HIV-1) RNA have been reported. We investigated CSF viral escape in subjects treated with commonly used antiretroviral therapy regimens in relation to intrathecal immune activation and central nervous system penetration effectiveness (CPE) rank. Sixty-nine neurologically asymptomatic subjects treated with antiretroviral therapy >6 months and plasma HIV-1 RNA <50 copies/mL were cross-sectionally included in the analysis. Antiretroviral therapy regimens included efavirenz, lopinavir/ritonavir or atazanavir/ritonavir combined with tenofovir, abacavir, or zidovudine and emtricitabine or lamivudine. HIV-1 RNA was analyzed with real-time polymerase chain reaction assays. Neopterin was analyzed by enzyme-linked immunosorbent assay. Seven (10%) of the 69 subjects had detectable CSF HIV-1 RNA, in median 121 copies/mL (interquartile range, 54-213 copies/mL). Subjects with detectable CSF virus had significantly higher CSF neopterin and longer duration of treatment. Previous treatment interruptions were more common in subjects with CSF escape. Central nervous system penetration effectiveness rank was not a significant predictor of detectable CSF virus or CSF neopterin levels. Viral escape in CSF is more common than previously reported, suggesting that low-grade central nervous system infection may continue in treated patients. Although these findings need extension in longitudinal studies, they suggest the utility of monitoring CSF responses, as new treatment combinations and strategies modify clinical practice.
NASA Astrophysics Data System (ADS)
Tingay, S. J.; Tremblay, C. D.; Croft, S.
2018-03-01
Following the results of the first systematic modern low-frequency search for extraterrestrial intelligence using the Murchison Widefield Array (MWA), which was directed toward a Galactic Center field, we report a second survey toward a Galactic Anticenter field. Using the MWA in the frequency range 99–122 MHz over a three-hour period, a 625 deg2 field centered on Orion KL (in the general direction of the Galactic Anticenter) was observed with a frequency resolution of 10 kHz. Within this field, 22 exoplanets are known. At the positions of these exoplanets, we searched for narrowband signals consistent with radio transmissions from intelligent civilizations. No such signals were found with a 5σ detection threshold. Our sample is significantly different to the 45 exoplanets previously studied with the MWA toward the Galactic Center, since the Galactic Center sample is dominated by exoplanets detected using microlensing, and hence at much larger distances than the exoplanets toward the Anticenter, found via radial velocity and transit detection methods. Our average effective sensitivity to extraterrestrial transmitter power is therefore much improved for the Anticenter sample. Added to this, our data processing techniques have improved, reducing our observational errors, leading to our best detection limit being reduced by approximately a factor of four compared to our previously published results.
Response Times to Gustatory–Olfactory Flavor Mixtures: Role of Congruence
Shepard, Timothy G.; Veldhuizen, Maria G.
2015-01-01
A mixture of perceptually congruent gustatory and olfactory flavorants (sucrose and citral) was previously shown to be detected faster than predicted by a model of probability summation that assumes stochastically independent processing of the individual gustatory and olfactory signals. This outcome suggests substantial integration of the signals. Does substantial integration also characterize responses to mixtures of incongruent flavorants? Here, we report simple response times (RTs) to detect brief pulses of 3 possible flavorants: monosodium glutamate, MSG (gustatory: “umami” quality), citral (olfactory: citrus quality), and a mixture of MSG and citral (gustatory–olfactory). Each stimulus (and, on a fraction of trials, water) was presented orally through a computer-operated, automated flow system, and subjects were instructed to press a button as soon as they detected any of the 3 non-water stimuli. Unlike responses previously found to the congruent mixture of sucrose and citral, responses here to the incongruent mixture of MSG and citral took significantly longer (RTs were greater) and showed lower detection rates than the values predicted by probability summation. This outcome suggests that the integration of gustatory and olfactory flavor signals is less extensive when the component flavors are perceptually incongruent rather than congruent, perhaps because incongruent flavors are less familiar. PMID:26304508
Detection of food intake from swallowing sequences by supervised and unsupervised methods.
Lopez-Meyer, Paulo; Makeyev, Oleksandr; Schuckers, Stephanie; Melanson, Edward L; Neuman, Michael R; Sazonov, Edward
2010-08-01
Studies of food intake and ingestive behavior in free-living conditions most often rely on self-reporting-based methods that can be highly inaccurate. Methods of Monitoring of Ingestive Behavior (MIB) rely on objective measures derived from chewing and swallowing sequences and thus can be used for unbiased study of food intake with free-living conditions. Our previous study demonstrated accurate detection of food intake in simple models relying on observation of both chewing and swallowing. This article investigates methods that achieve comparable accuracy of food intake detection using only the time series of swallows and thus eliminating the need for the chewing sensor. The classification is performed for each individual swallow rather than for previously used time slices and thus will lead to higher accuracy in mass prediction models relying on counts of swallows. Performance of a group model based on a supervised method (SVM) is compared to performance of individual models based on an unsupervised method (K-means) with results indicating better performance of the unsupervised, self-adapting method. Overall, the results demonstrate that highly accurate detection of intake of foods with substantially different physical properties is possible by an unsupervised system that relies on the information provided by the swallowing alone.
Detection of Food Intake from Swallowing Sequences by Supervised and Unsupervised Methods
Lopez-Meyer, Paulo; Makeyev, Oleksandr; Schuckers, Stephanie; Melanson, Edward L.; Neuman, Michael R.; Sazonov, Edward
2010-01-01
Studies of food intake and ingestive behavior in free-living conditions most often rely on self-reporting-based methods that can be highly inaccurate. Methods of Monitoring of Ingestive Behavior (MIB) rely on objective measures derived from chewing and swallowing sequences and thus can be used for unbiased study of food intake with free-living conditions. Our previous study demonstrated accurate detection of food intake in simple models relying on observation of both chewing and swallowing. This article investigates methods that achieve comparable accuracy of food intake detection using only the time series of swallows and thus eliminating the need for the chewing sensor. The classification is performed for each individual swallow rather than for previously used time slices and thus will lead to higher accuracy in mass prediction models relying on counts of swallows. Performance of a group model based on a supervised method (SVM) is compared to performance of individual models based on an unsupervised method (K-means) with results indicating better performance of the unsupervised, self-adapting method. Overall, the results demonstrate that highly accurate detection of intake of foods with substantially different physical properties is possible by an unsupervised system that relies on the information provided by the swallowing alone. PMID:20352335
Thin wetting film lensless imaging
NASA Astrophysics Data System (ADS)
Allier, C. P.; Poher, V.; Coutard, J. G.; Hiernard, G.; Dinten, J. M.
2011-03-01
Lensless imaging has recently attracted a lot of attention as a compact, easy-to-use method to image or detect biological objects like cells, but failed at detecting micron size objects like bacteria that often do not scatter enough light. In order to detect single bacterium, we have developed a method based on a thin wetting film that produces a micro-lens effect. Compared with previously reported results, a large improvement in signal to noise ratio is obtained due to the presence of a micro-lens on top of each bacterium. In these conditions, standard CMOS sensors are able to detect single bacterium, e.g. E.coli, Bacillus subtilis and Bacillus thuringiensis, with a large signal to noise ratio. This paper presents our sensor optimization to enhance the SNR; improve the detection of sub-micron objects; and increase the imaging FOV, from 4.3 mm2 to 12 mm2 to 24 mm2, which allows the detection of bacteria contained in 0.5μl to 4μl to 10μl, respectively.
Detection of radial motion depends on spatial displacement.
de la Malla, Cristina; López-Moliner, Joan
2010-06-01
Nakayama and Tyler (1981) disentangled the use of pure motion (speed) information from spatial displacement information for the detection of lateral motion. They showed that when positional cues were removed the contribution of motion or spatial information was dependent on the temporal frequency: for temporal frequencies lower than 1Hz the mechanism used to detect motion relied on speed information while for higher temporal frequencies a mechanism based on displacement information was used. Here we test whether the same dependency is also revealed in radial motion. In order to do so, we adapted the paradigm previously used by Nakayama and Tyler to obtain detection thresholds for lateral and radial motion by using a 2-IFC procedure. Subjects had to report which of the intervals contained the signal stimulus (33% coherent motion). We replicated the temporal frequency dependency for lateral motion but results indicate, however, that the detection of radial is always consistent with detecting a spatial displacement amplitude. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Caglayan, A. K.; Godiwala, P. M.
1985-01-01
The performance analysis results of a fault inferring nonlinear detection system (FINDS) using sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment is presented. First, a statistical analysis of the flight recorded sensor data was made in order to determine the characteristics of sensor inaccuracies. Next, modifications were made to the detection and decision functions in the FINDS algorithm in order to improve false alarm and failure detection performance under real modelling errors present in the flight data. Finally, the failure detection and false alarm performance of the FINDS algorithm were analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minute flight data. In general, the detection speed, failure level estimation, and false alarm performance showed a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed was faster for filter measurement sensors soon as MLS than for filter input sensors such as flight control accelerometers.
Fermi-LAT gamma ray detections of classical novae V1369 centauri 2013 and V5668 Sagittarii 2015
Cheung, C. C.; Jean, P.; Shore, S. N.; ...
2016-07-27
Here, we report the Fermi Large Area Telescope (LAT) detections of high-energy (>100 MeV) γ-ray emission from two recent optically bright classical novae, V1369 Centauri 2013 and V5668 Sagittarii 2015. Furthermore, at early times, Fermi target-of-opportunity observations prompted by their optical discoveries provided enhanced LAT exposure that enabled the detections of γ-ray onsets beginning ~2 days after their first optical peaks. Significant γ-ray emission was found extending to 39–55 days after their initial LAT detections, with systematically fainter and longer-duration emission compared to previous γ-ray-detected classical novae. These novae were distinguished by multiple bright optical peaks that encompassed the timemore » spans of the observed γ-rays. Finally, we discussed the γ-ray light curves and spectra of the two novae are presented along with representative hadronic and leptonic models, and comparisons with other novae detected by the LAT.« less
Conventional and PCR Detection of Aphelenchoides fragariae in Diverse Ornamental Host Plant Species
McCuiston, Jamie L.; Hudson, Laura C.; Subbotin, Sergei A.; Davis, Eric L.; Warfield, Colleen Y.
2007-01-01
A PCR-based diagnostic assay was developed for early detection and identification of Aphelenchoides fragariae directly in host plant tissues using the species-specific primers AFragFl and AFragRl that amplify a 169-bp fragment in the internal transcribed spacer (ITS1) region of ribosomal DNA. These species-specific primers did not amplify DNA from Aphelenchoides besseyi or Aphelenchoides ritzemabosi. The PCR assay was sensitive, detecting a single nematode in a background of plant tissue extract. The assay accurately detected A. fragariae in more than 100 naturally infected, ornamental plant samples collected in North Carolina nurseries, garden centers and landscapes, including 50 plant species not previously reported as hosts of Aphelenchoides spp. The detection sensitivity of the PCR-based assay was higher for infected yet asymptomatic plants when compared to the traditional, water extraction method for Aphelenchoides spp. detection. The utility of using NaOH extraction for rapid preparation of total DNA from plant samples infected with A. fragariae was demonstrated. PMID:19259510
Mergler, Rebecca; Kerstan, Andreas; Schmidt, Enno; Goebeler, Matthias; Benoit, Sandrine
2017-01-01
Pemphigus vegetans (PVeg) is a rare variant of pemphigus vulgaris characterized by pustules and/or papillomatous vegetations, preferentially affecting intertriginous and periorificial areas. Exceptional manifestations may be misdiagnosed resulting in delayed diagnosis and treatment. Diagnosis is confirmed by immunofluorescence and detection of anti-desmoglein (Dsg) 3 and/or anti-Dsg1 antibodies. We herein report an unusual manifestation of PVeg. At the time of first presentation, lesions were restricted to the right ring finger's tip. Although mucous membranes were initially not affected, high levels of anti-Dsg3 antibodies were detected while anti-Dsg1 and anti-desmocollin (Dsc) 1, 2, and 3 antibodies were absent. To compare our immunological findings with previous reports, all accessible Anglophone literature published since December 1988 was evaluated. We identified 52 patients suffering from PVeg, 7 of these showed anti-Dsg3 antibodies without any mucous membrane involvement. Notably, the detection of anti-Dsg1 and anti-Dsg3 antibodies does not necessarily correlate with the involvement of skin and/or mucous membranes. This might be due to more specific and complex antibody constellations in nonclassical or atypical pemphigus. PMID:28559810
Detecting large-scale networks in the human brain using high-density electroencephalography.
Liu, Quanying; Farahibozorg, Seyedehrezvan; Porcaro, Camillo; Wenderoth, Nicole; Mantini, Dante
2017-09-01
High-density electroencephalography (hdEEG) is an emerging brain imaging technique that can be used to investigate fast dynamics of electrical activity in the healthy and the diseased human brain. Its applications are however currently limited by a number of methodological issues, among which the difficulty in obtaining accurate source localizations. In particular, these issues have so far prevented EEG studies from reporting brain networks similar to those previously detected by functional magnetic resonance imaging (fMRI). Here, we report for the first time a robust detection of brain networks from resting state (256-channel) hdEEG recordings. Specifically, we obtained 14 networks previously described in fMRI studies by means of realistic 12-layer head models and exact low-resolution brain electromagnetic tomography (eLORETA) source localization, together with independent component analysis (ICA) for functional connectivity analysis. Our analyses revealed three important methodological aspects. First, brain network reconstruction can be improved by performing source localization using the gray matter as source space, instead of the whole brain. Second, conducting EEG connectivity analyses in individual space rather than on concatenated datasets may be preferable, as it permits to incorporate realistic information on head modeling and electrode positioning. Third, the use of a wide frequency band leads to an unbiased and generally accurate reconstruction of several network maps, whereas filtering data in a narrow frequency band may enhance the detection of specific networks and penalize that of others. We hope that our methodological work will contribute to rise of hdEEG as a powerful tool for brain research. Hum Brain Mapp 38:4631-4643, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
First Detection of a Pulsar Bow Shock Nebula in Far-UV: PSR J0437-4715
NASA Astrophysics Data System (ADS)
Rangelov, Blagoy; Pavlov, George G.; Kargaltsev, Oleg; Durant, Martin; Bykov, Andrei M.; Krassilchtchikov, Alexandre
2016-11-01
Pulsars traveling at supersonic speeds are often accompanied by cometary bow shocks seen in Hα. We report on the first detection of a pulsar bow shock in the far-ultraviolet (FUV). We detected it in FUV images of the nearest millisecond pulsar J0437-4715 obtained with the Hubble Space Telescope. The images reveal a bow-like structure positionally coincident with part of the previously detected Hα bow shock, with an apex at 10″ ahead of the moving pulsar. Its FUV luminosity, L(1250{--}2000 \\mathringA )≈ 5 × {10}28 erg s-1, exceeds the Hα luminosity from the same area by a factor of 10. The FUV emission could be produced by the shocked interstellar medium matter or, less likely, by relativistic pulsar wind electrons confined by strong magnetic field fluctuations in the bow shock. In addition, in the FUV images we found a puzzling extended (≃3″ in size) structure overlapping with the limb of the bow shock. If related to the bow shock, it could be produced by an inhomogeneity in the ambient medium or an instability in the bow shock. We also report on a previously undetected X-ray emission extending for about 5″ ahead of the pulsar, possibly a pulsar wind nebula created by shocked pulsar wind, with a luminosity L(0.5-8 keV) ˜ 3 × 1028 erg s-1. Based on observations made with the NASA/ESA Hubble Space Telescope, obtained at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS 5-26555. These observations are associated with programs GO 12917 and GO 10568.
Schaeffer, Anthony J. ; Chung, June ; Heretis, Konstantina ; Wong, Andrew ; Ledbetter, David H. ; Lese Martin, Christa
2004-01-01
Miscarriage is a condition that affects 10%–15% of all clinically recognized pregnancies, most of which occur in the first trimester. Approximately 50% of first-trimester miscarriages result from fetal chromosome abnormalities. Currently, G-banded chromosome analysis is used to determine if large-scale genetic imbalances are the cause of these pregnancy losses. This technique relies on the culture of cells derived from the fetus, a technique that has many limitations, including a high rate of culture failure, maternal overgrowth of fetal cells, and poor chromosome morphology. Comparative genomic hybridization (CGH)–array analysis is a powerful new molecular cytogenetic technique that allows genomewide analysis of DNA copy number. By hybridizing patient DNA and normal reference DNA to arrays of genomic clones, unbalanced gains or losses of genetic material across the genome can be detected. In this study, 41 product-of-conception (POC) samples, which were previously analyzed by G-banding, were tested using CGH arrays to determine not only if the array could identify all reported abnormalities, but also whether any previously undetected genomic imbalances would be discovered. The array methodology detected all abnormalities as reported by G-banding analysis and revealed new abnormalities in 4/41 (9.8%) cases. Of those, one trisomy 21 POC was also mosaic for trisomy 20, one had a duplication of the 10q telomere region, one had an interstitial deletion of chromosome 9p, and the fourth had an interstitial duplication of the Prader-Willi/Angelman syndrome region on chromosome 15q, which, if maternally inherited, has been implicated in autism. This retrospective study demonstrates that the DNA-based CGH-array technology overcomes many of the limitations of routine cytogenetic analysis of POC samples while enhancing the detection of fetal chromosome aberrations. PMID:15127362
Dale, Einar; Moan, Jon M; Osnes, Terje A; Bogsrud, Trond V
2017-02-01
FDG PET/CT is perceived as a valuable diagnostic tool in addition to the standard diagnostic workup for patients with isolated neck lymph nodes of squamous cell carcinoma of unknown primary (SCCUP). For patients with SCCUP intended for primary radiotherapy, we hypothesize that the previously reported FDG PET/CT detection rates are too high. From 2008 to 2015, 30 SCCUP patients were examined with FDG PET/CT. The objective of the FDG PET/CT examination was twofold: (1) improve the radiotherapy target definition, and (2) identify the primary cancer. Before the FDG PET/CT, the patients had been through a standard workup consisting of CT of the neck and chest, examination with flexible endoscopy with patient awake, panendoscopy and examination under general anesthesia, tonsillectomy and sometimes blind sampling biopsies, and MRI (floor of the mouth). All FDG PET/CTs were performed applying a flat table, head support and fixation mask as part of the radiotherapy treatment planning. Diagnostic CT with contrast was an integrated part of the PET/CT examination. Only 1/30 patients (cancer of the vallecula) had their primary cancer detected by FDG PET/CT. In addition, a non-biopsied patient with high uptake in the ipsilateral palatine tonsil was included, giving a detection rate of ≤7 % (95 % CI 2-21 %). In this retrospective study, we found that the FDG PET/CT detection rate of the primary for SCCUP patients is lower than previously reported. It is questionable whether FDG PET/CT is necessary for these patients when improved, advanced workup is available.
Very bright optical transient near the Trifid and Lagoon Nebulae
NASA Astrophysics Data System (ADS)
Dunsby, Peter
2018-03-01
Peter Dunsby (University of Cape Town) reports the detection of a very bright optical transient in the region between the Lagoon and Trifid Nebulae based on observations obtained from Cape Town on 20 March 2018, between 01:00 and 03:45 UT. The object was visible throughout the full duration of the observations and not seen when this field was observed previously (08 March 2018).
Detection of moisture and moisture related phenomena from Skylab. [Texas and Kansas
NASA Technical Reports Server (NTRS)
Eagleman, J. R. (Principal Investigator); Lin, W. C.
1974-01-01
The author has identified the following significant results. The high correlations between radiometric temperature and soil moisture content are shown to remain quite high for independent footprints of the S194 sensor. Since an analysis based on overlapping footprints had previously been reported with a high correlation, it was necessary to verify that the correlation did not arise from dependent data.
Update on Vaccine-Derived Polioviruses - Worldwide, January 2016-June 2017.
Jorba, Jaume; Diop, Ousmane M; Iber, Jane; Henderson, Elizabeth; Sutter, Roland W; Wassilak, Steven G F; Burns, Cara C
2017-11-03
In 1988, the World Health Assembly launched the Global Polio Eradication Initiative (GPEI) (1). Among the three wild poliovirus (WPV) serotypes, only type 1 (WPV1) has been detected since 2012. Since 2014, detection of WPV1 has been limited to three countries, with 37 cases in 2016 and 11 cases in 2017 as of September 27. The >99.99% decline worldwide in polio cases since the launch of the GPEI is attributable to the extensive use of the live, attenuated oral poliovirus vaccine (OPV) in mass vaccination campaigns and comprehensive national routine immunization programs. Despite its well-established safety record, OPV use can be associated with rare emergence of genetically divergent vaccine-derived polioviruses (VDPVs) whose genetic drift from the parental OPV strains indicates prolonged replication or circulation (2). VDPVs can also emerge among persons with primary immunodeficiencies (PIDs). Immunodeficiency-associated VDPVs (iVDPVs) can replicate for years in some persons with PIDs. In addition, circulating vaccine-derived polioviruses (cVDPVs) can emerge very rarely among immunologically normal vaccine recipients and their contacts in areas with inadequate OPV coverage and can cause outbreaks of paralytic polio. This report updates previous summaries regarding VDPVs (3). During January 2016-June 2017, new cVDPV outbreaks were identified, including two in the Democratic Republic of the Congo (DRC) (eight cases), and another in Syria (35 cases), whereas the circulation of cVDPV type 2 (cVDPV2) in Nigeria resulted in cVDPV2 detection linked to a previous emergence. The last confirmed case from the 2015-2016 cVDPV type 1 (cVDPV1) outbreak in Laos occurred in January 2016. Fourteen newly identified persons in 10 countries were found to excrete iVDPVs, and three previously reported patients in the United Kingdom and Iran (3) were still excreting type 2 iVDPV (iVDPV2) during the reporting period. Ambiguous VDPVs (aVDPVs), isolates that cannot be classified definitively, were found among immunocompetent persons and environmental samples in 10 countries. Cessation of all OPV use after certification of polio eradication will eliminate the risk for new VDPV infections.
Tao, Lin; Ma, Jing; Kunisue, Tatsuya; Libelo, E Laurence; Tanabe, Shinsuke; Kannan, Kurunthachalam
2008-11-15
The occurrence of perfluorinated compounds (PFCs) in human blood is known to be widespread; nevertheless, the sources of exposure to humans, including infants, are not well understood. In this study, breast milk collected from seven countries in Asia was analyzed (n=184) for nine PFCs, including perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA). In addition, five brands of infant formula (n=21) and 11 brands of dairy milk (n=12) collected from retail stores in the United States were analyzed, for comparison with PFC concentrations previously reported for breast milk from the U.S. PFOS was the predominant PFC detected in almost all Asian breast milk samples, followed by perfluorohexanesulfonate (PFHxS) and PFOA. Median concentrations of PFOS in breast milk from Asian countries varied significantly;the lowest concentration of 39.4 pg/mL was found in India, and the highest concentration of 196 pg/mL was found in Japan. The measured concentrations were similarto or less than the concentrations previously reported from Sweden, the United States, and Germany (median, 106-166 pg/mL). PFHxS was found in more than 70% of the samples analyzed from Japan, Malaysia, Philippines, and Vietnam, at mean concentrations ranging from 6.45 (Malaysia) to 15.8 (Philippines) pg/mL PFOA was found frequently only in samples from Japan; the mean concentration for that country was 77.7 pg/mL. None of the PFCs were detected in the infant-formula or dairy-milk samples from the U.S. except a few samples that contained concentrations close to the limit of detection. The estimated average daily intake of PFOS by infants from seven Asian countries, via breastfeeding, was 11.8 +/- 10.6 ng/kg bw/ day; this value is 7-12 times higher than the estimated adult dietary intakes previously reported from Germany, Canada, and Spain. The average daily intake of PFOA by Japanese infants was 9.6 +/- 4.9 ng/kg bw/day, a value 3-10 times greater than the estimated adult dietary intakes reported from Germany and Canada. The highest estimated daily intakes of PFOS and PFOA by infants from seven Asian countries studied were 1-2 orders of magnitude below the tolerable daily intake values recommended by the U.K. Food Standards Agency.
Internal carotid artery rupture caused by carotid shunt insertion
Illuminati, Giulio; Caliò, Francesco G.; Pizzardi, Giulia; Vietri, Francesco
2015-01-01
Introduction Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. Presentation of case A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Discussion Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Conclusion Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. PMID:26255001
O'Rourke, Declan J; Ryan, Stephanie; Salomons, Gajja; Jakobs, Cornelis; Monavari, Ahmad; King, Mary D
2009-05-01
Guanidinoacetate methyltransferase (GAMT) deficiency is a disorder of creatine biosynthesis, characterized by early-onset learning disability and epilepsy in most affected children. Severe expressive language delay is a constant feature even in the mildest clinical phenotypes.We report the clinical, biochemical, imaging, and treatment data of two female siblings (18y and 13y) with an unusual phenotype of GAMT deficiency. The oldest sibling had subacute onset of a movement disorder at age 17 years, later than has been previously reported. The younger sibling had better language skills than previously described in this disorder. After treatment with creatine, arginine restriction and ornithine-supplemented diet, seizure severity and movement disorder were reduced but cognition did not improve. This report confirms that GAMT deficiency, a heterogeneous, potentially treatable disorder, detected by increased levels of guanidinoacetate in body fluids (e.g. plasma or urine) or by an abnormal creatine peak on magnetic resonance spectroscopy, should be considered in patients of any age with unexplained, apparently static learning disability and epilepsy.
Al-Shahwan, I M; Abdalla, O A; Al-Saleh, M A; Amer, M A
2017-09-01
A total of 1368 symptomatic plant samples showing different virus-like symptoms such as mottling, chlorosis, mosaic, yellow mosaic, vein clearing and stunting were collected from alfalfa, weed and cultivated plant species growing in vicinity of alfalfa fields in five principal regions of alfalfa production in Saudi Arabia. DAS-ELISA test indicated occurrence of 11 different viruses in these samples, 10 of which were detected for the first time in Saudi Arabia. Eighty percent of the alfalfa samples and 97.5% of the weed and cultivated plants samples were found to be infected with one or more of these viruses. Nine weed plant species were found to harbor these viruses namely, Sonchus oleraceus, Chenopodium spp., Hibiscus spp., Cichorium intybus , Convolvulus arvensis , Malva parviflora , Rubus fruticosus , Hippuris vulgaris , and Flaveria trinervia . These viruses were also detected in seven cultivated crop plants growing adjacent to the alfalfa fields including Vigna unguiculata , Solanum tuberosum , Solanum melongena , Phaseolus vulgaris , Cucurbita maxima , Capsicum annuum , and Vicia faba . The newly reported viruses together with their respective percent of detection in alfalfa, and in both weeds and cultivated crop plant species together were as follows: Bean leaf roll virus (BLRV) {12.5 and 4.5%}, Lucerne transient streak virus (LTSV) {2.9 and 3.5%}, Bean yellow mosaic virus (BYMV) {1.4 and 4.5%}, Bean common mosaic virus (BCMV) {1.2 and 4.5%}, Red clover vein mosaic virus (RCVMV) {1.2 and 4%}, White clover mosaic virus (WCIMV) {1.0 and 5%}, Cucumber mosaic virus (CMV) {0.8 and 3%}, Pea streak virus (PeSV) {0.4 and 4.5%} and Tobacco streak virus (TSV) {0.3 and 2.5%}. Alfalfa mosaic virus (AMV), the previously reported virus in alfalfa, had the highest percentage of detection in alfalfa accounting for 58.4% and 62.8% in the weeds and cultivated plants. Peanut stunt virus (PSV) was also detected for the first time in Saudi Arabia with a 66.7% of infection in 90 alfalfa samples collected from the surveyed regions during the last visit that tested negative to all the previously detected viruses.
Dose and detectability for a cone-beam C-arm CT system revisited
Ganguly, Arundhuti; Yoon, Sungwon; Fahrig, Rebecca
2010-01-01
Purpose: The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose’s criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to (dose)1∕2. A more detailed analysis based on recent theoretical modeling of C-arm CT images is presented in this work. Methods: The signal and noise propagations in a C-arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x-ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose-criteria-based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results. Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to (dose)1∕3 and (dose)1∕2.8, respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose-criterion-based normalization. Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization. PMID:20527560
NASA Technical Reports Server (NTRS)
Spruce, Joseph P.; Hargrove, William; Gasser, Jerry; Smoot, James; Kuper, Philip D.
2014-01-01
This presentation discusses MODIS NDVI change detection methods and products used in the ForWarn Early Warning System (EWS) for near real time (NRT) recognition and tracking of regionally evident forest disturbances throughout the conterminous US (CONUS). The latter has provided NRT forest change products to the forest health protection community since 2010, using temporally processed MODIS Aqua and Terra NDVI time series data to currently compute and post 6 different forest change products for CONUS every 8 days. Multiple change products are required to improve detectability and to more fully assess the nature of apparent disturbances. Each type of forest change product reports per pixel percent change in NDVI for a given 24 day interval, comparing current versus a given historical baseline NDVI. EMODIS 7 day expedited MODIS MOD13 data are used to obtain current and historical NDVIs, respectively. Historical NDVI data is processed with Time Series Product Tool (TSPT); and 2) the Phenological Parameters Estimation Tool (PPET) software. While each change products employ maximum value compositing (MVC) of NDVI, the design of specific products primarily differs in terms of the historical baseline. The three main change products use either 1, 3, or all previous years of MVC NDVI as a baseline. Another product uses an Adaptive Length Compositing (ALC) version of MVC to derive an alternative current NDVI that is the freshest quality NDVI as opposed to merely the MVC NDVI across a 24 day time frame. The ALC approach can improve detection speed by 8 to 16 days. ForWarn also includes 2 change products that improve detectability of forest disturbances in lieu of climatic fluctuations, especially in the spring and fall. One compares current MVC NDVI to the zonal maximum under the curve NDVI per pheno-region cluster class, considering all previous years in the MODIS record. The other compares current maximum NDVI to the mean of maximum NDVI for all previous MODIS years.
Dong, Tao; Pires, Nuno Miguel Matos
2017-08-15
This work reports a novel optical microfluidic biosensor with highly sensitive organic photodetectors (OPDs) for absorbance-based detection of salivary protein biomarkers at the point of care. The compact and miniaturized biosensor has comprised OPDs made of polythiophene-C 70 bulk heterojunction for the photoactive layer; whilst a calcium-free cathode interfacial layer, made of linear polyethylenimine, was incorporated to the photodetectors to enhance the low cost. The OPDs realized onto a glass chip were aligned to antibody-functionalized chambers of a poly(methyl methacrylate) microfluidic chip, in where immunogold-silver assays were conducted. The biosensor has detected IL-8, IL-1β and MMP-8 protein in spiked saliva with high detection specificity and short analysis time exhibiting detection limits between 80pgmL -1 and 120pgmL -1 . The result for IL-8 was below the clinical established cut-off of 600pgmL -1 , which revealed the potential of the biosensor to early detection of oral cancer. The detection limit was also comparable to other previously reported immunosensors performed with bulky instrumentation or using inorganic photodetectors. The optical detection sensitivity of the polythiophene-C 70 OPD was enhanced by optimizing the thickness of the photoactive layer and anode interfacial layer prior to the saliva immunoassays. Further, the biosensor was tested with unspiked human saliva samples, and the results of measuring IL-8 and IL-1β were in statistical agreement with those provided by two commercial assays of ELISA. The optical microfluidic biosensor reported hereby offers an attractive and cost-effective tool to diagnostics or screening purposes at the point of care. Copyright © 2017 Elsevier B.V. All rights reserved.
A CCD search for distant satellites of asteroids 3 Juno and 146 Lucina
NASA Technical Reports Server (NTRS)
Stern, S. Alan; Barker, Edwin S.
1992-01-01
The results of CCD searches for satellites of asteroids 146 Lucina and 3 Juno are reported. Juno is one of the largest asteroids (D = 244 km); no previous deep imaging search for satellites around it has been reported. A potential occultation detection of a small satellite orbiting 146 Lucina (D = 137 km) km was reported by Arlot et al. (1985), but has not been confirmed. Using the 2.1 m reflector at McDonald Observatory in 1990 and 1991 with a CCD camera equipped with a 2.7 arc-sec radius occulting disk, limiting magnitudes of m(sub R) = 19.5 and m(sub R) = 21.4 were achieved around these two asteroids. This corresponds to objects of 1.6 km radius at Juno's albedo and distance, and 0.6 km radius at Lucina's albedo and distance. No satellite detections were made. Unless satellites were located behind our occultation mask, these two asteroids do not have satellites larger than the radii given above.
OPAD-EDIFIS Real-Time Processing
NASA Technical Reports Server (NTRS)
Katsinis, Constantine
1997-01-01
The Optical Plume Anomaly Detection (OPAD) detects engine hardware degradation of flight vehicles through identification and quantification of elemental species found in the plume by analyzing the plume emission spectra in a real-time mode. Real-time performance of OPAD relies on extensive software which must report metal amounts in the plume faster than once every 0.5 sec. OPAD software previously written by NASA scientists performed most necessary functions at speeds which were far below what is needed for real-time operation. The research presented in this report improved the execution speed of the software by optimizing the code without changing the algorithms and converting it into a parallelized form which is executed in a shared-memory multiprocessor system. The resulting code was subjected to extensive timing analysis. The report also provides suggestions for further performance improvement by (1) identifying areas of algorithm optimization, (2) recommending commercially available multiprocessor architectures and operating systems to support real-time execution and (3) presenting an initial study of fault-tolerance requirements.
Valen-Sendstad, Kristian; Mardal, Kent-André; Steinman, David A
2013-01-18
High-frequency flow fluctuations in intracranial aneurysms have previously been reported in vitro and in vivo. On the other hand, the vast majority of image-based computational fluid dynamics (CFD) studies of cerebral aneurysms report periodic, laminar flow. We have previously demonstrated that transitional flow, consistent with in vivo reports, can occur in a middle cerebral artery (MCA) bifurcation aneurysm when ultra-high-resolution direct numerical simulation methods are applied. The object of the present study was to investigate if such high-frequency flow fluctuations might be more widespread in adequately-resolved CFD models. A sample of N=12 anatomically realistic MCA aneurysms (five unruptured, seven ruptured), was digitally segmented from CT angiograms. Four were classified as sidewall aneurysms, the other eight as bifurcation aneurysms. Transient CFD simulations were carried out assuming a steady inflow velocity of 0.5m/s, corresponding to typical peak systolic conditions at the MCA. To allow for detection of clinically-reported high-frequency flow fluctuations and resulting flow structures, temporal and spatial resolutions of the CFD simulations were in the order of 0.1 ms and 0.1 mm, respectively. A transient flow response to the stationary inflow conditions was found in five of the 12 aneurysms, with energetic fluctuations up to 100 Hz, and in one case up to 900 Hz. Incidentally, all five were ruptured bifurcation aneurysms, whereas all four sidewall aneurysms, including one ruptured case, quickly reached a stable, steady state solution. Energetic, rapid fluctuations may be overlooked in CFD models of bifurcation aneurysms unless adequate temporal and spatial resolutions are used. Such fluctuations may be relevant to the mechanobiology of aneurysm rupture, and to a recently reported dichotomy between predictors of rupture likelihood for bifurcation vs. sidewall aneurysms. Copyright © 2012 Elsevier Ltd. All rights reserved.
Progress toward polio eradication--Worldwide, 2013-2014.
Moturi, Edna K; Porter, Kimberly A; Wassilak, Steven G F; Tangermann, Rudolf H; Diop, Ousmane M; Burns, Cara C; Jafari, Hamid
2014-05-30
In 1988, the World Health Assembly of the World Health Organization (WHO) resolved to interrupt wild poliovirus (WPV) transmission worldwide, and in 2012, the World Health Assembly declared the completion of global polio eradication a programmatic emergency for public health. By 2013, the annual number of WPV cases had decreased by >99% since 1988, and only three countries remained that had never interrupted WPV transmission: Afghanistan, Nigeria, and Pakistan. This report summarizes global progress toward polio eradication during 2013-2014 and updates previous reports. In 2013, a total of 416 WPV cases were reported globally from eight countries, an 86% increase from the 223 WPV cases reported from five countries in 2012. This upsurge in 2013 was caused by a 60% increase in WPV cases detected in Pakistan, and by outbreaks in five previously polio-free countries resulting from international spread of WPV. In 2014, as of May 20, a total of 82 WPV cases had been reported worldwide, compared with 34 cases during the same period in 2013. Polio cases caused by circulating vaccine-derived poliovirus (cVDPV) were detected in eight countries in 2013 and in two countries so far in 2014. To achieve polio eradication in the near future, further efforts are needed to 1) address health worker safety concerns in areas of armed conflict in priority countries, 2) to prevent further spread of WPV and new outbreaks after importation into polio-free countries, and 3) to strengthen surveillance globally. Based on the international spread of WPV to date in 2014, the WHO Director General has issued temporary recommendations to reduce further international exportation of WPV through vaccination of persons traveling from currently polio-affected countries.
Occurrence of arsenic in ground water of Suffolk County, New York, 1997–2002
Cartwright, Richard A.
2004-01-01
Water-quality data from public and private drinking-water supply wells that were sampled from October 1997 through March 2001 in Suffolk County, New York were evaluated to define the occurrence and concentrations of arsenic throughout the county. The data bases of the Suffolk County Water Authority (SCWA) and the Suffolk County Department of Health Services (SCDHS) included 14 wells at which arsenic concentrations approached or exceeded the 2002 U.S. Environmental Protection Agency (USEPA) drinking-water guideline of 10 micrograms per liter (µg/L).As a followup, 19 wells were sampled from June through August 2002; 7 were wells previously reported to have had high arsenic concentrations; 7 were near other wells reported to have high concentrations, and the remaining 5 were in areas where detectable concentrations of arsenic were suspected. Arsenic concentrations near 10 µg/L were detected at only 2 of the 19 wells sampled; arsenic concentrations in samples from the remaining 17 wells were reported as less than the USGS Central Laboratory reporting limits of 2 µg/L or 4 µg/L.The elevated concentrations previously reported (1997 through 2001) for at least three of the wells were due to incompletely flushed carbon filters in the supply-well system or were typographical errors. A decrease in arsenic concentration was indicated at six of the seven resampled wells; no reasons are apparent. Arsenic concentrations in ground water that exceed drinking-water guidelines were found only at one site. On the basis of limited sampling data available for this study, the concentrations of arsenic above drinking-water standards (10 µg/L) do not appear to indicate a countywide problem with regards to arsenic concentrations in ground water.
High Detectivity Graphene-Silicon Heterojunction Photodetector.
Li, Xinming; Zhu, Miao; Du, Mingde; Lv, Zheng; Zhang, Li; Li, Yuanchang; Yang, Yao; Yang, Tingting; Li, Xiao; Wang, Kunlin; Zhu, Hongwei; Fang, Ying
2016-02-03
A graphene/n-type silicon (n-Si) heterojunction has been demonstrated to exhibit strong rectifying behavior and high photoresponsivity, which can be utilized for the development of high-performance photodetectors. However, graphene/n-Si heterojunction photodetectors reported previously suffer from relatively low specific detectivity due to large dark current. Here, by introducing a thin interfacial oxide layer, the dark current of graphene/n-Si heterojunction has been reduced by two orders of magnitude at zero bias. At room temperature, the graphene/n-Si photodetector with interfacial oxide exhibits a specific detectivity up to 5.77 × 10(13) cm Hz(1/2) W(-1) at the peak wavelength of 890 nm in vacuum, which is highest reported detectivity at room temperature for planar graphene/Si heterojunction photodetectors. In addition, the improved graphene/n-Si heterojunction photodetectors possess high responsivity of 0.73 A W(-1) and high photo-to-dark current ratio of ≈10(7) . The current noise spectral density of the graphene/n-Si photodetector has been characterized under ambient and vacuum conditions, which shows that the dark current can be further suppressed in vacuum. These results demonstrate that graphene/Si heterojunction with interfacial oxide is promising for the development of high detectivity photodetectors. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A magnetoelectric flux gate: new approach for weak DC magnetic field detection.
Chu, Zhaoqiang; Shi, Huaduo; PourhosseiniAsl, Mohammad Javad; Wu, Jingen; Shi, Weiliang; Gao, Xiangyu; Yuan, Xiaoting; Dong, Shuxiang
2017-08-17
The magnetic flux gate sensors based on Faraday's Law of Induction are widely used for DC or extremely low frequency magnetic field detection. Recently, as the fast development of multiferroics and magnetoelectric (ME) composite materials, a new technology based on ME coupling effect is emerging for potential devices application. Here, we report a magnetoelectric flux gate sensor (MEFGS) for weak DC magnetic field detection for the first time, which works on a similar magnetic flux gate principle, but based on ME coupling effect. The proposed MEFGS has a shuttle-shaped configuration made of amorphous FeBSi alloy (Metglas) serving as both magnetic and magnetostrictive cores for producing a closed-loop high-frequency magnetic flux and also a longitudinal vibration, and one pair of embedded piezoelectric PMN-PT fibers ([011]-oriented Pb(Mg,Nb)O 3 -PbTiO 3 single crystal) serving as ME flux gate in a differential mode for detecting magnetic anomaly. In this way, the relative change in output signal of the MEFGS under an applied DC magnetic anomaly of 1 nT was greatly enhanced by a factor of 4 to 5 in comparison with the previous reports. The proposed ME flux gate shows a great potential for magnetic anomaly detections, such as magnetic navigation, magnetic based medical diagnosis, etc.
Mannion, Damien J; Donkin, Chris; Whitford, Thomas J
2017-01-01
We investigated the relationship between psychometrically-defined schizotypy and the ability to detect a visual target pattern. Target detection is typically impaired by a surrounding pattern (context) with an orientation that is parallel to the target, relative to a surrounding pattern with an orientation that is orthogonal to the target (orientation-dependent contextual modulation). Based on reports that this effect is reduced in those with schizophrenia, we hypothesised that there would be a negative relationship between the relative score on psychometrically-defined schizotypy and the relative effect of orientation-dependent contextual modulation. We measured visual contrast detection thresholds and scores on the Oxford-Liverpool Inventory of Feelings and Experiences (O-LIFE) from a non-clinical sample ( N = 100). Contrary to our hypothesis, we find an absence of a monotonic relationship between the relative magnitude of orientation-dependent contextual modulation of visual contrast detection and the relative score on any of the subscales of the O-LIFE. The apparent difference of this result with previous reports on those with schizophrenia suggests that orientation-dependent contextual modulation may be an informative condition in which schizophrenia and psychometrically-defined schizotypy are dissociated. However, further research is also required to clarify the strength of orientation-dependent contextual modulation in those with schizophrenia.
Chauhan, Nidhi; Chawla, Sheetal; Pundir, C S; Jain, Utkarsh
2017-03-15
An essential biological sensor for acetylcholine (ACh) detection is constructed by immobilizing enzymes, acetylcholinesterase (AChE) and choline oxidase (ChO), on the surface of iron oxide nanoparticles (Fe 2 O 3 NPs), poly(3,4-ethylenedioxythiophene) (PEDOT)-reduced graphene oxide (rGO) nanocomposite modified fluorine doped tin oxide (FTO). The qualitative and quantitative measurements of nanocomposites properties were accomplished by scanning electron microscope (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). This prepared biological sensor delineated a wide linear range of 4.0nM to 800μM with a response time less than 4s and detection limit (based on S/N ratio) of 4.0nM. The sensor showed perfect sensitivity, excessive selectivity and stability for longer period of time during storage. Besides its very high-sensitivity, the biosensor has displayed a low detection limit which is reported for the first time in comparison to previously reported ACh sensors. By fabricating Fe 2 O 3 NPs/rGO/PEDOT modified FTO electrode for determining ACh level in serum samples, the applicability of biosensor has increased immensely as the detection of the level neurotransmitter is first priority for patients suffering from memory loss or Alzheimer's disease (AD). Copyright © 2016 Elsevier B.V. All rights reserved.
Charge exchange in galaxy clusters
NASA Astrophysics Data System (ADS)
Gu, Liyi; Mao, Junjie; de Plaa, Jelle; Raassen, A. J. J.; Shah, Chintan; Kaastra, Jelle S.
2018-03-01
Context. Though theoretically expected, the charge exchange emission from galaxy clusters has never been confidently detected. Accumulating hints were reported recently, including a rather marginal detection with the Hitomi data of the Perseus cluster. As previously suggested, a detection of charge exchange line emission from galaxy clusters would not only impact the interpretation of the newly discovered 3.5 keV line, but also open up a new research topic on the interaction between hot and cold matter in clusters. Aim. We aim to perform the most systematic search for the O VIII charge exchange line in cluster spectra using the RGS on board XMM-Newton. Methods: We introduce a sample of 21 clusters observed with the RGS. In order to search for O VIII charge exchange, the sample selection criterion is a >35σ detection of the O VIII Lyα line in the archival RGS spectra. The dominating thermal plasma emission is modeled and subtracted with a two-temperature thermal component, and the residuals are stacked for the line search. The systematic uncertainties in the fits are quantified by refitting the spectra with a varying continuum and line broadening. Results: By the residual stacking, we do find a hint of a line-like feature at 14.82 Å, the characteristic wavelength expected for oxygen charge exchange. This feature has a marginal significance of 2.8σ, and the average equivalent width is 2.5 × 10-4 keV. We further demonstrate that the putative feature can be barely affected by the systematic errors from continuum modeling and instrumental effects, or the atomic uncertainties of the neighboring thermal lines. Conclusions: Assuming a realistic temperature and abundance pattern, the physical model implied by the possible oxygen line agrees well with the theoretical model proposed previously to explain the reported 3.5 keV line. If the charge exchange source indeed exists, we expect that the oxygen abundance could have been overestimated by 8-22% in previous X-ray measurements that assumed pure thermal lines. These new RGS results bring us one step forward to understanding the charge exchange phenomenon in galaxy clusters.
Central serous choroidopathy in the Hallermann-Streiff Syndrome.
Blair, N P; Brockhurst, R J; Lee, W
1981-08-01
Central serous choroidopathy was observed in a young patient with the Hallermann-Streiff syndrome. Typical features of this syndrome include microphthalmos, proportionate dwarfism, dyscephaly with birdlike facies, dental abnormalities, and hypotrichosis. Exceptional aspects of this case include age of onset (11 years), high hyperopic refractive error (+ 13.00 sphere), and multiple recurrences caused by six separate documented leaks from the choroid. Fundus changes previously reported in the Hallermann-Streiff syndrome, interpreted as chorioretinal pigmentary changes, may have been secondary to previous undiagnosed central serous choroidopathy. Periodic ophthalmoscopy should be performed and may detect unrecognized episodes of central serous choroidopathy for which photocoagulation would be beneficial.
Waterborne disease outbreak detection: an integrated approach using health administrative databases.
Coly, S; Vincent, N; Vaissiere, E; Charras-Garrido, M; Gallay, A; Ducrot, C; Mouly, D
2017-08-01
Hundreds of waterborne disease outbreaks (WBDO) of acute gastroenteritis (AGI) due to contaminated tap water are reported in developed countries each year. Such outbreaks are probably under-detected. The aim of our study was to develop an integrated approach to detect and study clusters of AGI in geographical areas with homogeneous exposure to drinking water. Data for the number of AGI cases are available at the municipality level while exposure to tap water depends on drinking water networks (DWN). These two geographical units do not systematically overlap. This study proposed to develop an algorithm which would match the most relevant grouping of municipalities with a specific DWN, in order that tap water exposure can be taken into account when investigating future disease outbreaks. A space-time detection method was applied to the grouping of municipalities. Seven hundred and fourteen new geographical areas (groupings of municipalities) were obtained compared with the 1,310 municipalities and the 1,706 DWN. Eleven potential WBDO were identified in these groupings of municipalities. For ten of them, additional environmental investigations identified at least one event that could have caused microbiological contamination of DWN in the days previous to the occurrence of a reported WBDO.
Zehetleitner, Michael; Proulx, Michael J; Müller, Hermann J
2009-11-01
In efficient search for feature singleton targets, additional singletons (ASs) defined in a nontarget dimension are frequently found to interfere with performance. All search tasks that are processed via a spatial saliency map of the display would be predicted to be subject to such AS interference. In contrast, dual-route models, such as feature integration theory, assume that singletons are detected not via a saliency map, but via a nonspatial route that is immune to interference from cross-dimensional ASs. Consistent with this, a number of studies have reported absent interference effects in detection tasks. However, recent work suggests that the failure to find such effects may be due to the particular frequencies at which ASs were presented, as well as to their relative saliency. These two factors were examined in the present study. In contrast to previous reports, cross-dimensional ASs were found to slow detection (target-present and target-absent) responses, modulated by both their frequency of occurrence and saliency (relative to the target). These findings challenge dual-route models and support single-route models, such as dimension weighting and guided search.
Mycoplasma detection and isolation from one-humped camels (Camelus dromedarius).
Mederos-Iriarte, Lidia E; Poveda, José B; Poveda, Carlos G; Vega-Orellana, Orestes M; Gutiérrez, Carlos; Corbera, Juan A; Ramírez, Ana S
2014-10-01
In scientific literature, a small amount of information is found concerning mycoplasmosis in camel species. Mycoplasma (M.) arginini, Acholeplasma (A.) laidlawii, and Acholeplasma oculi have been reported to be isolated from these host species. Serologically positive results have been reported for Mycoplasma mycoides subsp. mycoides SC type, Mycoplasma capricolum subsp. capripneumoniae, and M. mycoides subsp. capri. The aims of this study were to detect, isolate, and identify mycoplasmas from camels (Camelus dromedarius). Initially, saliva and ear smears plus conjunctival and vaginal secretions were taken from five female animals, but only conjunctival secretions in three male animals, all belonging to the same farm. An unknown mycoplasma was isolated from one of the vagina samples. Additionally, another unknown and uncultured mycoplasma was detected with molecular biology in the same sample. In the second stage, 23 vaginal secretions were taken from the same farm plus another secretion from a different one. Ten isolates of the same unknown and previously isolated mycoplasma were detected, nine of them recovered from the vagina of female camels. Some mycoplasmas have been related to reproductive disorders; however, there is no evidence that the isolated mycoplasmas are related to such disorders.
Genital HSV Shedding among Kenyan Women Initiating Antiretroviral Therapy
Manguro, Griffins O.; Masese, Linnet N.; Deya, Ruth W.; Magaret, Amalia; Wald, Anna; McClelland, R. Scott; Graham, Susan M.
2016-01-01
Objectives Genital ulcer disease (GUD) prevalence increases in the first month of antiretroviral treatment (ART), followed by a return to baseline prevalence by month 3. Since most GUD is caused by herpes simplex virus type 2 (HSV-2), we hypothesized that genital HSV detection would follow a similar pattern after treatment initiation. Methods We conducted a prospective cohort study of 122 HSV-2 and HIV-1 co-infected women with advanced HIV disease who initiated ART and were followed closely with collection of genital swab specimens for the first three months of treatment. Results At baseline, the HSV detection rate was 32%, without significant increase in genital HSV detection noted during the first month or the third month of ART. HIV-1 shedding declined during this period; no association was also noted between HSV and HIV-1 shedding during this period. Conclusion Because other studies have reported increased HSV detection in women initiating ART and we have previously reported an increase in GUD during early ART, it may be prudent to counsel HIV-1 infected women initiating ART that HSV shedding in the genital tract may continue after ART initiation. PMID:27683204
The FIDELIS initiative: innovative strategies for increased case finding.
Hinderaker, S G; Rusen, I D; Chiang, C-Y; Yan, L; Heldal, E; Enarson, D A
2011-01-01
Low-income, high tuberculosis (TB) burden countries. To compare case finding of new smear-positive pulmonary TB patients in projects funded to apply innovative approaches. Prospective application of innovative approaches to case finding within routine services to determine the numbers of additional cases detected and the cost per additional case detected, according to the type of approach applied. Between 2003 and 2007, 51 FIDELIS projects were implemented in 18 countries; 273,239 cases were reported, of which 85,267 were additional to the number reported in the previous year. The median cost per additional case was US$103. The interventions employed were: 1) social mobilisation and information, education and communication; 2) engagement of the private sector; 3) innovative approaches for microscopy services; 4) enhanced or semi-active case finding; 5) health systems strengthening; and 6) use of incentives. None of these was significantly more likely to detect additional cases or to have a lower cost per additional case than any of the others. While there was a substantial increase in cases detected, at a moderate cost per additional case, we were unable to show that any single intervention had an advantage over the others.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Ziqiang
1999-12-10
Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based onmore » monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10 -8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.« less
A deep intronic mutation in the SLC12A3 gene leads to Gitelman syndrome.
Nozu, Kandai; Iijima, Kazumoto; Nozu, Yoshimi; Ikegami, Ei; Imai, Takehide; Fu, Xue Jun; Kaito, Hiroshi; Nakanishi, Koichi; Yoshikawa, Norishige; Matsuo, Masafumi
2009-11-01
Many mutations have been detected in the SLC12A3 gene of Gitelman syndrome (GS, OMIM 263800) patients. In previous studies, only one mutant allele was detected in approximately 20 to 41% of patients with GS; however, the exact reason for the nonidentification has not been established. In this study, we used RT-PCR using mRNA to investigate for the first time transcript abnormalities caused by deep intronic mutation. Direct sequencing analysis of leukocyte DNA identified one base insertion in exon 6 (c.818_819insG), but no mutation was detected in another allele. We analyzed RNA extracted from leukocytes and urine sediments and detected unknown sequence containing 238bp between exons 13 and 14. The genomic DNA analysis of intron 13 revealed a single-base substitution (c.1670-191C>T) that creates a new donor splice site within the intron resulting in the inclusion of a novel cryptic exon in mRNA. This is the first report of creation of a splice site by a deep intronic single-nucleotide change in GS and the first report to detect the onset mechanism in a patient with GS and missing mutation in one allele. This molecular onset mechanism may partly explain the poor success rate of mutation detection in both alleles of patients with GS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This report provides a detailed summary of the activities carried out to sample groundwater at Waste Area Grouping (WAG) 6. The analytical results for samples collected during Phase 1, Activity 2 of the WAG 6 Resource Conservation and Recovery Act Facility Investigation (RFI) are also presented. In addition, analytical results for Phase 1, activity sampling events for which data were not previously reported are included in this TM. A summary of the groundwater sampling activities of WAG 6, to date, are given in the Introduction. The Methodology section describes the sampling procedures and analytical parameters. Six attachments are included. Attachmentsmore » 1 and 2 provide analytical results for selected RFI groundwater samples and ORNL sampling event. Attachment 3 provides a summary of the contaminants detected in each well sampled for all sampling events conducted at WAG 6. Bechtel National Inc. (BNI)/IT Corporation Contract Laboratory (IT) RFI analytical methods and detection limits are given in Attachment 4. Attachment 5 provides the Oak Ridge National Laboratory (ORNL)/Analytical Chemistry Division (ACD) analytical methods and detection limits and Resource Conservation and Recovery Act (RCRA) quarterly compliance monitoring (1988--1989). Attachment 6 provides ORNL/ACD groundwater analytical methods and detection limits (for the 1990 RCRA semi-annual compliance monitoring).« less
Water Ice in 2060 Chiron and Its Implications for Centaurs and Kuiper Belt Objects.
Luu; Jewitt; Trujillo
2000-03-10
We report the detection of water ice in the Centaur 2060 Chiron, based on near-infrared spectra (1.0-2.5 µm) taken with the 3.8 m United Kingdom Infrared Telescope and the 10 m Keck Telescope. The appearance of this ice is correlated with the recent decline in Chiron's cometary activity: the decrease in the coma cross section allows previously hidden solid-state surface features to be seen. We predict that water ice is ubiquitous among Centaurs and Kuiper Belt objects, but its surface coverage varies from object to object and thus determines its detectability and the occurrence of cometary activity.
(abstract) Effect of Long Period Ocean Tides on the Earth's Rotation
NASA Technical Reports Server (NTRS)
Gross, R. S.; Chao, B. F.; Desai, S.
1996-01-01
The second-degree zonal tide raising potential, which is responsible for tidal changes in the Earth's rotation rate and length-of-day, is symmetric about the polar axis and hence can excite the Earth's polar motion only through its action upon nonaxisymmetric features of the Earth such as the oceans. Ocean tidal excitation of polar motion in the diurnal and semidiurnal tidal bands has been previously detected and extensively examined. Here, the detection of ocean tidal excitation of polar motion in the long-period tidal band, specifically at the Mf' (13.63-day) and Mf (13.66-day) tidal frequencies, is reported.
Elston, Ralph A; Moore, James; Abbott, Cathryn L
2012-12-03
Mikrocytos mackini, causative agent of Denman Island disease in Pacific oysters Crassostrea gigas and other oyster species, was found in 2011 in a previously unreported host, the Kumamoto oyster C. sikamea, in Humboldt Bay, California, USA. The detection was also the first reported finding of M. mackini in California. Prevalence was estimated as high as approximately 27% from pooled samples analyzed by PCR. Higher prevalence appeared related to longer residence time in the bay and somewhat colder than typical winter seawater temperatures. No M. mackini was detected in Humboldt Bay juvenile Kumamoto oysters or Pacific oyster brood or seed stock in 2011 or 2012.
Barnes, Agnieszka Szot; Haker, Steven J; Mulkern, Robert V; So, Minna; D'Amico, Anthony V; Tempany, Clare M
2005-12-01
Brachytherapy targeted to the peripheral zone with magnetic resonance imaging (MRI) guidance is a prostate cancer treatment option with potentially fewer complications than other treatments. Follow-up MRI when failure is suspected is, however, difficult because of radiation-induced changes. Furthermore, MR spectroscopy (MRS) is compromised by susceptibility artifacts from radioactive seeds in the peripheral zone. We report a case in which combined MRI/MRS was useful for the detection of prostate cancer in the transitional zone in patients previously treated with MR-guided brachytherapy. We propose that MRI/MRS can help detect recurrent prostate cancer, guide prostate biopsy, and help manage salvage treatment decisions.
Efficient entanglement distribution over 200 kilometers.
Dynes, J F; Takesue, H; Yuan, Z L; Sharpe, A W; Harada, K; Honjo, T; Kamada, H; Tadanaga, O; Nishida, Y; Asobe, M; Shields, A J
2009-07-06
Here we report the first demonstration of entanglement distribution over a record distance of 200 km which is of sufficient fidelity to realize secure communication. In contrast to previous entanglement distribution schemes, we use detection elements based on practical avalanche photodiodes (APDs) operating in a self-differencing mode. These APDs are low-cost, compact and easy to operate requiring only electrical cooling to achieve high single photon detection efficiency. The self-differencing APDs in combination with a reliable parametric down-conversion source demonstrate that entanglement distribution over ultra-long distances has become both possible and practical. Consequently the outlook is extremely promising for real world entanglement-based communication between distantly separated parties.
NASA Astrophysics Data System (ADS)
Wren, Stephen P.; Piletsky, Sergey A.; Karim, Kal; Gascoine, Paul; Lacey, Richard; Sun, Tong; Grattan, Kenneth T. V.
2014-05-01
Previously, we have developed chemical sensors using fibre optic-based techniques for the detection of Cocaine, utilising molecularly imprinted polymers (MIPs) containing fluorescein moieties as the signalling groups. Here, we report the computational design of a fluorophore which was incorporated into a MIP for the generation of a novel sensor that offers improved sensitivity for Cocaine with a detection range of 1-100μM. High selectivity for Cocaine over a suite of known Cocaine interferants (25μM) was also demonstrated by measuring changes in the intensity of fluorescence signals received from the sensor.
Detection of new in-path targets by drivers using Stop & Go Adaptive Cruise Control.
Stanton, Neville A; Dunoyer, Alain; Leatherland, Adam
2011-05-01
This paper reports on the design and evaluation of in-car displays used to support Stop & Go Adaptive Cruise Control. Stop & Go Adaptive Cruise Control is an extension of Adaptive Cruise Control, as it is able to bring the vehicle to a complete stop. Previous versions of Adaptive Cruise Control have only operated above 26 kph. The greatest concern for these technologies is the appropriateness of the driver's response in any given scenario. Three different driver interfaces were proposed to support the detection of modal, spatial and temporal changes of the system: an iconic display, a flashing iconic display, and a representation of the radar. The results show that drivers correctly identified more changes detected by the system with the radar display than with the other displays, but higher levels of workload accompanied this increased detection. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Zhang, Junwen; Yu, Jianjun; Chi, Nan
2015-01-01
All optical method is considered as a promising technique for high symbol rate Nyquist signal generation, which has attracted a lot of research interests for high spectral-efficiency and high-capacity optical communication system. In this paper, we extend our previous work and report the fully experimental demonstration of polarization-division multiplexed (PDM) all-optical Nyquist signal generation based on Sinc-shaped Nyquist pulse with advanced modulation formats, fiber-transmission and single-receiver full-band coherent detection. Using this scheme, we have successfully demonstrated the generation, fiber transmission and single-receiver full-band coherent detection of all-optical Nyquist PDM-QPSK and PDM-16QAM signals up to 125-GBaud. 1-Tb/s single-carrier PDM-16QAM signal generation and full-band coherent detection is realized, which shows the advantage and feasibility of the single-carrier all-optical Nyquist signals. PMID:26323238
SWAN - Detection of explosives by means of fast neutron activation analysis
NASA Astrophysics Data System (ADS)
Gierlik, M.; Borsuk, S.; Guzik, Z.; Iwanowska, J.; Kaźmierczak, Ł.; Korolczuk, S.; Kozłowski, T.; Krakowski, T.; Marcinkowski, R.; Swiderski, L.; Szeptycka, M.; Szewiński, J.; Urban, A.
2016-10-01
In this work we report on SWAN, the experimental, portable device for explosives detection. The device was created as part of the EU Structural Funds Project "Accelerators & Detectors" (POIG.01.01.02-14-012/08-00), with the goal to increase beneficiary's expertise and competencies in the field of neutron activation analysis. Previous experiences and budged limitations lead toward a less advanced design based on fast neutron interactions and unsophisticated data analysis with the emphasis on the latest gamma detection and spectrometry solutions. The final device has been designed as a portable, fast neutron activation analyzer, with the software optimized for detection of carbon, nitrogen and oxygen. SWAN's performance in the role of explosives detector is elaborated in this paper. We demonstrate that the unique features offered by neutron activation analysis might not be impressive enough when confronted with practical demands and expectations of a generic homeland security customer.
OBSERVATIONS OF ROTATING RADIO TRANSIENTS WITH THE FIRST STATION OF THE LONG WAVELENGTH ARRAY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, G. B.; Stovall, K.; McCrackan, M.
2016-11-10
Rotating radio transients (RRATs) are a subclass of pulsars first identified in 2006 that are detected only in searches for single pulses and not through their time averaged emission. Here, we present the results of observations of 19 RRATs using the first station of the Long Wavelength Array (LWA1) at frequencies between 30 and 88 MHz. The RRATs observed here were first detected in higher frequency pulsar surveys. Of the 19 RRATs observed, two sources were detected and their dispersion measures, periods, pulse profiles, and flux densities are reported and compared to previous higher frequency measurements. We find a lowmore » detection rate (11%), which could be a combination of the lower sensitivity of LWA1 compared to higher frequency telescopes, and the result of scattering by the interstellar medium or a spectral turnover.« less
NASA Astrophysics Data System (ADS)
Wang, Zhiyu; Fan, ZheFeng
2018-01-01
A highly sensitive sensor for detection of histidine (His) based on the nitrogen-doped graphene quantum dots (N-GQDs)-Cu2 + system has been designed. The N-GQDs were synthesized by one-step hydrothermal approach according to previous report. The fluorescence of N-GQDs can be effectively quenched by Cu2 + due to the binding between Cu2 + and functional groups on the surface of N-GQDs. The high affinity of His to Cu2 + enables Cu2 + to be dissociated from the surface of N-GQDs and recovering the fluorescence. The sensor displayed a sensitive response to His in the concentration range of 0-35 μmol L- 1, with a detection limit of 72.2 nmol L- 1. The proposed method is successfully applied to detect His in samples with a recovery range of 96-102%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baba, Justin S; Koju, Vijay; John, Dwayne O
2016-01-01
The modulation of the state of polarization of photons due to scatter generates associated geometric phase that is being investigated as a means for decreasing the degree of uncertainty in back-projecting the paths traversed by photons detected in backscattered geometry. In our previous work, we established that polarimetrically detected Berry phase correlates with the mean photon penetration depth of the backscattered photons collected for image formation. In this work, we report on the impact of state-of-linear-polarization (SOLP) filtering on both the magnitude and population distributions of image forming detected photons as a function of the absorption coefficient of the scatteringmore » sample. The results, based on Berry phase tracking implemented Polarized Monte Carlo Code, indicate that sample absorption plays a significant role in the mean depth attained by the image forming backscattered detected photons.« less
SERS-based pesticide detection by using nanofinger sensors
NASA Astrophysics Data System (ADS)
Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong
2015-01-01
Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.
Zhang, Yun; Liu, Fang; Nie, Jinfang; Jiang, Fuyang; Zhou, Caibin; Yang, Jiani; Fan, Jinlong; Li, Jianping
2014-05-07
In this paper, we report for the first time an electrochemical biosensor for single-step, reagentless, and picomolar detection of a sequence-specific DNA-binding protein using a double-stranded, electrode-bound DNA probe terminally modified with a redox active label close to the electrode surface. This new methodology is based upon local repression of electrolyte diffusion associated with protein-DNA binding that leads to reduction of the electrochemical response of the label. In the proof-of-concept study, the resulting electrochemical biosensor was quantitatively sensitive to the concentrations of the TATA binding protein (TBP, a model analyte) ranging from 40 pM to 25.4 nM with an estimated detection limit of ∼10.6 pM (∼80 to 400-fold improvement on the detection limit over previous electrochemical analytical systems).
Chowdhury, Shubhajit Roy
2012-04-01
The paper reports of a Field Programmable Gate Array (FPGA) based embedded system for detection of QRS complex in a noisy electrocardiogram (ECG) signal and thereafter differential diagnosis of tachycardia and tachyarrhythmia. The QRS complex has been detected after application of entropy measure of fuzziness to build a detection function of ECG signal, which has been previously filtered to remove power line interference and base line wander. Using the detected QRS complexes, differential diagnosis of tachycardia and tachyarrhythmia has been performed. The entire algorithm has been realized in hardware on an FPGA. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity (Se) of 99.74% and accuracy of 99.5% is achieved when tested using single channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in literature. Using the system, 200 patients have been diagnosed with an accuracy of 98.5%.
NASA Technical Reports Server (NTRS)
Caglayan, A. K.; Godiwala, P. M.; Morrell, F. R.
1985-01-01
This paper presents the performance analysis results of a fault inferring nonlinear detection system (FINDS) using integrated avionics sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment. First, an overview of the FINDS algorithm structure is given. Then, aircraft state estimate time histories and statistics for the flight data sensors are discussed. This is followed by an explanation of modifications made to the detection and decision functions in FINDS to improve false alarm and failure detection performance. Next, the failure detection and false alarm performance of the FINDS algorithm are analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minutes of flight data. Results indicate that the detection speed, failure level estimation, and false alarm performance show a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed is faster for filter measurement sensors such as MLS than for filter input sensors such as flight control accelerometers. Finally, the progress in modifications of the FINDS algorithm design to accommodate flight computer constraints is discussed.
Korğalı, Elif Ünver; Yavuz, Amine; Şimşek, Cemile Ece Çağlar; Güney, Cengiz; Kurtulgan, Hande Küçük; Başer, Burak; Atalar, Mehmet Haydar; Özer, Hatice; Eğilmez, Hatice Reyhan
2018-04-01
Megacystis microcolon intestinal hypoperistalsis syndrome (MMIHS) is characterized by bladder distension without urinary tract obstruction, decreased or absent intestinal peristalsis and microcolon. Although the definitive cause remains unknown, changes in the ACTG2 gene are thought to be responsible for the intestinal and bladder hypoperistalsis. This female newborn with MMIHS had a c.532C>A /p.Arg178Ser heterozygous de novo mutation detected in the ACTG2 gene. Normal immature ganglion cells, normal calretinin punctate positivity, maintence of smooth muscle actin immunoreactivity, and decreased numbers of interstitial cells of Cajal(ICCs) were detected. This previously unreported c.532C>A /p.Arg178Ser heterozygous de novo mutation in the ACTG2 gene may lead to a severe form of MMIHS.
Detection of 16 Gamma-Ray Pulsars Through Blind Frequency Searches Using the Fermi LAT
Abdo, A. A.; Ackermann, M.; Ajello, M.; ...
2009-07-02
Pulsars are rapidly rotating, highly magnetized neutron stars emitting radiation across the electromagnetic spectrum. Although there are more than 1800 known radio pulsars, until recently only seven were observed to pulse in gamma rays, and these were all discovered at other wavelengths. The Fermi Large Area Telescope (LAT) makes it possible to pinpoint neutron stars through their gamma-ray pulsations. In this paper, we report the detection of 16 gamma-ray pulsars in blind frequency searches using the LAT. Most of these pulsars are coincident with previously unidentified gamma-ray sources, and many are associated with supernova remnants. Finally, direct detection of gamma-raymore » pulsars enables studies of emission mechanisms, population statistics, and the energetics of pulsar wind nebulae and supernova remnants.« less
Second Epoch VLBA Calibrator Survey Observations - VCS-II
NASA Technical Reports Server (NTRS)
Gordon, David; Jacobs, Christopher; Beasley, Anthony; Peck, Alison; Gaume, Ralph; Charlot, Patrick; Fey, Alan; Ma, Chopo; Titov, Oleg; Boboltz, David
2016-01-01
Six very successful VLBA calibrator survey campaigns were run between 1994 and 2007 to build up a large list of compact radio sources with positions precise enough for use as VLBI phase reference calibrators. We report on the results of a second epoch VLBA Calibrator Survey campaign (VCS-II) in which 2400 VCS sources were re-observed at X and S bands in order to improve the upcoming third realization of the International Celestial Reference Frame (ICRF3) as well as to improve their usefulness as VLBI phase reference calibrators. In this survey, some 2062 previously detected sources and 324 previously undetected sources were detected and revised positions are presented. Average position uncertainties for the reobserved sources were reduced from 1.14 and 1.98 mas to 0.24 and 0.41 mas in RA and Declination, respectively, or by nearly a factor of 5. Minimum detected flux values were approximately 15 and 28 mJy in X and S bands, respectively, and median total fluxes are approximately 230 and 280 mJy. The vast majority of these sources are flat-spectrum sources, with approximately 82% having spectral indices greater than -0.5.
Second Epoch VLBA Calibrator Survey Observations: VCS-II
NASA Astrophysics Data System (ADS)
Gordon, David; Jacobs, Christopher; Beasley, Anthony; Peck, Alison; Gaume, Ralph; Charlot, Patrick; Fey, Alan; Ma, Chopo; Titov, Oleg; Boboltz, David
2016-06-01
Six very successful Very Long Baseline Array (VLBA) calibrator survey campaigns were run between 1994 and 2007 to build up a large list of compact radio sources with positions precise enough for use as very long baseline interferometry (VLBI) phase reference calibrators. We report on the results of a second epoch VLBA Calibrator Survey campaign (VCS-II) in which 2400 VCS sources were re-observed in the X and S bands in order to improve the upcoming third realization of the International Celestial Reference Frame (ICRF3) as well as to improve their usefulness as VLBI phase reference calibrators. In this survey, some 2062 previously detected sources and 324 previously undetected sources were detected and revised positions are presented. Average position uncertainties for the re-observed sources were reduced from 1.14 and 1.98 mas to 0.24 and 0.41 mas in R.A. and decl., respectively, or by nearly a factor of 5. Minimum detected flux values were approximately 15 and 28 mJy in the X and S bands, respectively, and median total fluxes are approximately 230 and 280 mJy. The vast majority of these sources are flat-spectrum sources, with ˜82% having spectral indices greater than -0.5.
Necrotizing meningoencephalitis in atypical dog breeds: a case series and literature review.
Cooper, J J; Schatzberg, S J; Vernau, K M; Summers, B A; Porter, B F; Siso, S; Young, B D; Levine, J M
2014-01-01
Canine necrotizing meningoencephalitis (NME) is a fatal, noninfectious inflammatory disease of unknown etiology. NME has been reported only in a small number of dog breeds, which has led to the presumption that it is a breed-restricted disorder. Our objective was to describe histopathologically confirmed NME in dog breeds in which the condition has not been reported previously and to provide preliminary evidence that NME affects a wider spectrum of dog breeds than previously reported. Four dogs with NME. Archives from 3 institutions and from 1 author's (BS) collection were reviewed to identify histopathologically confirmed cases of NME in breeds in which the disease has not been reported previously. Age, sex, breed, survival from onset of clinical signs, and histopathologic findings were evaluated. Necrotizing meningoencephalitis was identified in 4 small dog breeds (Papillon, Shih Tzu, Coton de Tulear, and Brussels Griffon). Median age at clinical evaluation was 2.5 years. Histopathologic abnormalities included 2 or more of the following: lymphoplasmacytic or histiocytic meningoencephalitis or encephalitis, moderate-to-severe cerebrocortical necrosis, variable involvement of other anatomic locations within the brain (cerebellum, brainstem), and absence of detectable infectious agents. Until now, NME has only been described in 5 small dog breeds. We document an additional 4 small breeds previously not shown to develop NME. Our cases further illustrate that NME is not a breed-restricted disorder and should be considered in the differential diagnosis for dogs with signalment and clinical signs consistent with inflammatory brain disease. Copyright © 2013 by the American College of Veterinary Internal Medicine.
NASA Technical Reports Server (NTRS)
Hughes, John P.
1999-01-01
We report the detection, using data from the Advanced Satellite for Cosmology and Astrophysics (ASCA), of a hard X-ray source in the vicinity of the radio pulsar PSR B1853+01, which is located within the supernova remnant (SNR) W44. PSR B1853+01, a 267 ms pulsar, has to date been detected only in the radio band. Previous observations at soft X-ray energies (e.g., with ROSAT HRI) have failed to detect any significant X-ray emission (pulsed or unpulsed) from the pulsar. In addition, no high-energy emission (approx. > 4 keV) has been detected previously from W44. Over the 0.5-4.0 keV band, the ASCA data show soft thermal emission from W44, with a morphology very similar to that observed earlier by Einstein and ROSAT. In the high-energy band (4.0-9.5 keV), the SNR is, for the most part, invisible, although a source coincident with the position of PSR B1853+01 is evident. The observed ASCA spectra are consistent with a power-law origin (photon index approx. 2.3) for the X-ray emission from this source at a flux level (flux density approx. 0.5 micro Jy at I keV) consistent with previous upper limits. The maximum allowed size for the source is determined directiv from the ASCA data (<5 min.), while the minimum size is derived from the nondetection of a point source in the ROSAT HRI data (approx. > 30 sec.). Timing analysis of the hard X-ray source failed to detect pulsations at the pulsar's period. Based on these lines of evidence, we conclude that the new hard source in W44 represents an X-ray synchrotron nebula associated with PSR B1853+01, rather than the beamed output of the pulsar itself. This discoverv adds W44 to the small group of previously known plerionic SNRs This nebula lies at the low end of, but is consistent with, the correlation between X-ray luminosity and pulsar spin-down energy loss found for such objects, lending further support to our interpretation.
ISO ammonia line absorption reveals a layer of hot gas veiling Sgr B2
NASA Astrophysics Data System (ADS)
Ceccarelli, C.; Baluteau, J.-P.; Walmsley, M.; Swinyard, B. M.; Caux, E.; Sidher, S. D.; Cox, P.; Gry, C.; Kessler, M.; Prusti, T.
2002-02-01
We report the first results of the unbiased spectral high resolution survey obtained towards Sgr B2 with the Long Wavelength Spectrometer on board ISO. The survey detected more than one hundreds lines from several molecules. Ammonia is the molecule with the largest number (21) of detected lines in the survey. We detected NH3 transitions from levels with energies from 45 to 500 cm-1. The detected transitions are from both para and ortho ammonia and metastable and non-metastable levels. All the ammonia lines are in absortion against the FIR continuum of Sgr B2. With such a large number of detected lines in such a large range of energy levels, we could very efficiently constrain the main parameters of the absorbing gas layer. The gas is at (700 +/- 100) K and has a density lower than 104 cm-3. The total NH3 column density in the layer is (3+/- 1) x 1016 cm-2, equally shared between ortho and para ammonia. Given the derived relatively high gas temperature and ammonia column density, our observations support the hypothesis previously proposed of a layer of shocked gas between us and Sgr B2. We also discuss previous observations of far infrared line absorption from other molecules, like H2O and HF, in the light of this hot absorbing layer. If the absorption is done by the hot absorbing layer rather than by the warm envelope surrounding Sgr B2, as was previously supposed in order to interpret the mentioned observations, the derived H2O and HF abundances are one order of magitude larger than previously estimated. Yet, the present H2O and HF observations do not allow one to disentangle the absorption from the hot layer against the warm envelope. Our conclusions are hence that care should be applied when interpreting the absorption observations in Sgr B2, as the hot layer clearly seen in the ammonia transitions may substantially contribute to the absorption. ISO is an ESA project with instruments funded by ESA Member States (especially the PI countries: France, Germany, The Netherlands and the United Kingdom) and with the participation of ISAS and NASA.
Crimean Congo Hemorrhagic Fever Virus and Alkhurma (Alkhumra) Virus in Ticks in Djibouti.
Horton, Katherine C; Fahmy, Nermeen T; Watany, Noha; Zayed, Alia; Mohamed, Abro; Ahmed, Ammar Abdo; Rollin, Pierre E; Dueger, Erica L
2016-10-01
Crimean Congo hemorrhagic fever virus and Alkhumra virus, not previously reported in Djibouti, were detected among 141 (infection rate = 15.7 per 100, 95% CI: 13.4-18.1) tick pools from 81 (37%) cattle and 2 (infection rate = 0.2 per 100, 95% CI: 0.0-0.7) tick pools from 2 (1%) cattle, respectively, collected at an abattoir in 2010 and 2011.
Hurst, William J; Stanley, Bruce; Glinski, Jan A; Davey, Matthew; Payne, Mark J; Stuart, David A
2009-10-15
This report describes the characterization of a series of commercially available procyanidin standards ranging from dimers DP = 2 to decamers DP = 10 for the determination of procyanidins from cocoa and chocolate. Using a combination of HPLC with fluorescence detection and MALDI-TOF mass spectrometry, the purity of each standard was determined and these data were used to determine relative response factors. These response factors were compared with other response factors obtained from published methods. Data comparing the procyanidin analysis of a commercially available US dark chocolate calculated using each of the calibration methods indicates divergent results and demonstrate that previous methods may significantly underreport the procyanidins in cocoa-containing products. These results have far reaching implications because the previous calibration methods have been used to develop data for a variety of scientific reports, including food databases and clinical studies.
Gorshein, Elan; Wei, Catherine; Ambrosy, Susan; Budney, Shanna; Vivas, Juliana; Shenkerman, Angelika; Manago, Jacqueline; McGrath, Mary Kate; Tyno, Anne; Lin, Yong; Patel, Vimal; Gharibo, Mecide; Schaar, Dale; Jenq, Robert R; Khiabanian, Hossein; Strair, Roger
2017-05-01
Graft-versus-host disease (GVHD) is a major adverse effect associated with allogeneic stem cell transplant. Previous studies in mice indicated that administration of the probiotic Lactobacillus rhamnosus GG can reduce the incidence of GVHD after hematopoietic stem cell transplant. Here we report results from the first randomized probiotic enteric regimen trial in which allogenic hematopoietic stem cell patients were supplemented with Lactobacillus rhamnosus GG. Gut microbiome analysis confirmed a previously reported gut microbiome association with GVHD. However, the clinical trial was terminated when interim analysis did not detect an appreciable probiotic-related change in the gut microbiome or incidence of GVHD. Additional studies are necessary to determine whether probiotics can alter the incidence of GVHD after allogeneic stem cell transplant. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The 51.8 micron (0 3) line emission observed in four galactic H 2 regions
NASA Technical Reports Server (NTRS)
Melnick, G.; Gull, G. E.; Harwit, M.
1978-01-01
The (0 III) 51.8 microns line from four H II regions, M42, M17, W51 and NGC 6375A was detected. Respective line strengths are 7 x 10 to the minus 15 power, 1.0 x 10 to the minus 14 power, 2.1 x 10 to the minus 15 power and 2.6 x 10 to the minus 15 power watt cm/2. Observations are consistent with previously reported line position and place the line at 51.80 + or 0.05 micron. When combined with the 88.35 microns (0 III) reported earlier, clumping seems to be an important factor in NGC 6375A and M42 and to a lesser extent in W51 and M17. The combined data also suggest an (0 III) abundance of approximately 3 x 0.0001 sub n e' a factor of 2 greater than previously assumed.
Probe Heating Method for the Analysis of Solid Samples Using a Portable Mass Spectrometer
Kumano, Shun; Sugiyama, Masuyuki; Yamada, Masuyoshi; Nishimura, Kazushige; Hasegawa, Hideki; Morokuma, Hidetoshi; Inoue, Hiroyuki; Hashimoto, Yuichiro
2015-01-01
We previously reported on the development of a portable mass spectrometer for the onsite screening of illicit drugs, but our previous sampling system could only be used for liquid samples. In this study, we report on an attempt to develop a probe heating method that also permits solid samples to be analyzed using a portable mass spectrometer. An aluminum rod is used as the sampling probe. The powdered sample is affixed to the sampling probe or a droplet of sample solution is placed on the tip of the probe and dried. The probe is then placed on a heater to vaporize the sample. The vapor is then introduced into the portable mass spectrometer and analyzed. With the heater temperature set to 130°C, the developed system detected 1 ng of methamphetamine, 1 ng of amphetamine, 3 ng of 3,4-methylenedioxymethamphetamine, 1 ng of 3,4-methylenedioxyamphetamine, and 0.3 ng of cocaine. Even from mixtures consisting of clove powder and methamphetamine powder, methamphetamine ions were detected by tandem mass spectrometry. The developed probe heating method provides a simple method for the analysis of solid samples. A portable mass spectrometer incorporating this method would thus be useful for the onsite screening of illicit drugs. PMID:26819909
A Search for Rapidly Pulsating Hot Subdwarf Stars in the GALEX Survey
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boudreaux, Thomas M.; Barlow, Brad N.; Soto, Alan Vasquez
NASA’s Galaxy Evolution Explorer ( GALEX ) provided near- and far-UV observations for approximately 77% of the sky over a 10-year period; however, the data reduction pipeline initially only released single NUV and FUV images to the community. The recently released Python module gPhoton changes this, allowing calibrated time-series aperture photometry to be extracted easily from the raw GALEX data set. Here we use gPhoton to generate light curves for all hot subdwarf B (sdB) stars that were observed by GALEX , with the intention of identifying short-period, p-mode pulsations. We find that the spacecraft’s short visit durations, uneven gapsmore » between visits, and dither pattern make the detection of hot subdwarf pulsations difficult. Nonetheless, we detect UV variations in four previously known pulsating targets and report their UV pulsation amplitudes and frequencies. Additionally, we find that several other sdB targets not previously known to vary show promising signals in their periodograms. Using optical follow-up photometry with the Skynet Robotic Telescope Network, we confirm p-mode pulsations in one of these targets, LAMOST J082517.99+113106.3, and report it as the most recent addition to the sdBV{sub r} class of variable stars.« less
The absolute threshold of cone vision
Koeing, Darran; Hofer, Heidi
2013-01-01
We report measurements of the absolute threshold of cone vision, which has been previously underestimated due to sub-optimal conditions or overly strict subjective response criteria. We avoided these limitations by using optimized stimuli and experimental conditions while having subjects respond within a rating scale framework. Small (1′ fwhm), brief (34 msec), monochromatic (550 nm) stimuli were foveally presented at multiple intensities in dark-adapted retina for 5 subjects. For comparison, 4 subjects underwent similar testing with rod-optimized stimuli. Cone absolute threshold, that is, the minimum light energy for which subjects were just able to detect a visual stimulus with any response criterion, was 203 ± 38 photons at the cornea, ∼0.47 log units lower than previously reported. Two-alternative forced-choice measurements in a subset of subjects yielded consistent results. Cone thresholds were less responsive to criterion changes than rod thresholds, suggesting a limit to the stimulus information recoverable from the cone mosaic in addition to the limit imposed by Poisson noise. Results were consistent with expectations for detection in the face of stimulus uncertainty. We discuss implications of these findings for modeling the first stages of human cone vision and interpreting psychophysical data acquired with adaptive optics at the spatial scale of the receptor mosaic. PMID:21270115
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martha, A.; Ferrel, R.E.; Hittner, H.M.
1994-09-01
Aniridia (iris hyplasia) is a autosomal dominant congenital disorder of the eye. Mutations in the human aniridia (PAX6) gene have now been identified in many patients from various ethnic groups. In the present study we describe new mutations in this gene. Out of four mutations found, three were novel mutations; the fourth one is identical to the previously reported mutations (C{yields}T transition at nt 240). The three novel mutations analyzed were in the glycine-rich region (two) and in the proline/serine/threonine-rich (PST) region (one). Previously no mutations were reported for the glycine-rich region in humans. One of the mutations found inmore » this region is associated with cataracts in an aniridia family. The other splice mutation found in the PST domain is associated with anosmia (lack of sensation to smell) in a sporadic aniridia case. Two of the mutations presented here, one in the glycine-rich region and the other in the PST domain, were not detected by SSCR. These mutations could be detected by using MDE gel and heteroduplex information. All mutations found in the present study are similar in that 32 of 33 PAX6 mutations result in protein truncation and haploinsufficiency.« less
DANCING IN THE DARK: NEW BROWN DWARF BINARIES FROM KERNEL PHASE INTERFEROMETRY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pope, Benjamin; Tuthill, Peter; Martinache, Frantz, E-mail: bjsp@physics.usyd.edu.au, E-mail: p.tuthill@physics.usyd.edu.au, E-mail: frantz@naoj.org
2013-04-20
This paper revisits a sample of ultracool dwarfs in the solar neighborhood previously observed with the Hubble Space Telescope's NICMOS NIC1 instrument. We have applied a novel high angular resolution data analysis technique based on the extraction and fitting of kernel phases to archival data. This was found to deliver a dramatic improvement over earlier analysis methods, permitting a search for companions down to projected separations of {approx}1 AU on NIC1 snapshot images. We reveal five new close binary candidates and present revised astrometry on previously known binaries, all of which were recovered with the technique. The new candidate binariesmore » have sufficiently close separation to determine dynamical masses in a short-term observing campaign. We also present four marginal detections of objects which may be very close binaries or high-contrast companions. Including only confident detections within 19 pc, we report a binary fraction of at least #Greek Lunate Epsilon Symbol#{sub b} = 17.2{sub -3.7}{sup +5.7}%. The results reported here provide new insights into the population of nearby ultracool binaries, while also offering an incisive case study of the benefits conferred by the kernel phase approach in the recovery of companions within a few resolution elements of the point-spread function core.« less
Arif, Mohammad; Busot, Grethel Y.; Mann, Rachel; Rodoni, Brendan; Liu, Sanzhen; Stack, James P.
2016-01-01
Rathayibacter toxicus is a gram-positive bacterium that infects the floral parts of several Poaceae species in Australia. Bacterial ooze is often produced on the surface of infected plants and bacterial galls are produced in place of seed. R. toxicus is a regulated plant pathogen in the U.S. yet reliable detection and diagnostic tools are lacking. To better understand this geographically-isolated plant pathogen, genetic variation as a function of geographic location, host species, and date of isolation was determined for isolates collected over a forty-year period. Discriminant analyses of recently collected and archived isolates using Multi-Locus Sequence Typing (MLST) and Inter-Simple Sequence Repeats (ISSR) identified three populations of R. toxicus; RT-I and RT-II from South Australia and RT-III from Western Australia. Population RT-I, detected in 2013 and 2014 from the Yorke Peninsula in South Australia, is a newly emerged population of R. toxicus not previously reported. Commonly used housekeeping genes failed to discriminate among the R. toxicus isolates. However, strategically selected and genome-dispersed MLST genes representing an array of cellular functions from chromosome replication, antibiotic resistance and biosynthetic pathways to bacterial acquired immunity were discriminative. Genetic variation among isolates within the RT-I population was less than the within-population variation for the previously reported RT-II and RT-III populations. The lower relative genetic variation within the RT-I population and its absence from sampling over the past 40 years suggest its recent emergence. RT-I was the dominant population on the Yorke Peninsula during the 2013–2014 sampling period perhaps indicating a competitive advantage over the previously detected RT-II population. The potential for introduction of this bacterial plant pathogen into new geographic areas provide a rationale for understanding the ecological and evolutionary trajectories of R. toxicus. PMID:27219107
Arif, Mohammad; Busot, Grethel Y; Mann, Rachel; Rodoni, Brendan; Liu, Sanzhen; Stack, James P
2016-01-01
Rathayibacter toxicus is a gram-positive bacterium that infects the floral parts of several Poaceae species in Australia. Bacterial ooze is often produced on the surface of infected plants and bacterial galls are produced in place of seed. R. toxicus is a regulated plant pathogen in the U.S. yet reliable detection and diagnostic tools are lacking. To better understand this geographically-isolated plant pathogen, genetic variation as a function of geographic location, host species, and date of isolation was determined for isolates collected over a forty-year period. Discriminant analyses of recently collected and archived isolates using Multi-Locus Sequence Typing (MLST) and Inter-Simple Sequence Repeats (ISSR) identified three populations of R. toxicus; RT-I and RT-II from South Australia and RT-III from Western Australia. Population RT-I, detected in 2013 and 2014 from the Yorke Peninsula in South Australia, is a newly emerged population of R. toxicus not previously reported. Commonly used housekeeping genes failed to discriminate among the R. toxicus isolates. However, strategically selected and genome-dispersed MLST genes representing an array of cellular functions from chromosome replication, antibiotic resistance and biosynthetic pathways to bacterial acquired immunity were discriminative. Genetic variation among isolates within the RT-I population was less than the within-population variation for the previously reported RT-II and RT-III populations. The lower relative genetic variation within the RT-I population and its absence from sampling over the past 40 years suggest its recent emergence. RT-I was the dominant population on the Yorke Peninsula during the 2013-2014 sampling period perhaps indicating a competitive advantage over the previously detected RT-II population. The potential for introduction of this bacterial plant pathogen into new geographic areas provide a rationale for understanding the ecological and evolutionary trajectories of R. toxicus.
Abdul-Baki, Heitham; Schoen, Robert E; Dean, Katie; Rose, Sherri; Leffler, Daniel A; Kuganeswaran, Eliathamby; Morris, Michele; Carrell, David; Mehrotra, Ateev
2015-10-01
Colonoscopy is the predominant method for colorectal cancer screening in the United States. Previous studies have documented variation across physicians in colonoscopy quality as measured by the adenoma detection rate (ADR). ADR is the primary quality measure of colonoscopy examinations and an indicator of the likelihood of subsequent colorectal cancer. There is interest in mechanisms to improve the ADR. In Central Illinois, a local employer and a quality improvement organization partnered to publically report physician colonoscopy quality. We assessed whether this initiative was associated with an improvement in the ADR. We compared ADRs before and after public reporting at a private practice endoscopy center with 11 gastroenterologists in Peoria, Illinois, who participated in the initiative. To generate the ADR, colonoscopy and pathology reports from examinations performed over 4 years at the endoscopy center were analyzed by using previously validated natural language processing software. A central Illinois endoscopy center. The ADR in the pre-public reporting period was 34.3% and 39.2% in the post-public reporting period (an increase of 4.9%, P < .001). The increase in the right-sided ADR was 5.1% (P < .01), whereas the increase in the left-sided ADR was 2.1% (P < .05). The increase in the ADR was 7.8% for screening colonoscopies (P < 0.05) and 3.5% for nonscreening colonoscopies (P < .05). All but 1 physician's ADR increased (range -2.7% to 10.5%). There was no statistically significant change in the advanced ADR (increase of 0.8%, P = .22). There was no concurrent control group to assess whether the increased ADR was due to a secular trend. A public reporting initiative on colonoscopy quality was associated with an increase in ADR. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Prevalence of BPH and lower urinary tract symptoms in West Africans.
Chokkalingam, A P; Yeboah, E D; Demarzo, A; Netto, G; Yu, K; Biritwum, R B; Tettey, Y; Adjei, A; Jadallah, S; Li, Y; Chu, L W; Chia, D; Niwa, S; Partin, A; Thompson, I M; Roehrborn, C; Hoover, R N; Hsing, A W
2012-06-01
BPH and lower urinary tract symptoms (LUTS) are very common among older men in Western countries. However, the prevalence of these two conditions in the developing countries is less clear. We assessed the age-standardized prevalence of BPH and/or LUTS among West Africans in a probability sample of 950 men aged 50-74 in Accra, Ghana, with no evidence of biopsy-confirmed prostate cancer after screening with PSA and digital rectal examination (DRE). Information on LUTS was based on self-reports of the International Prostate Symptom Score (IPSS). BPH was estimated using DRE, PSA levels and imputed prostate volume. The prevalence of DRE-detected enlarged prostate was 62.3%, while that of PSA≥1.5 ng ml(-1) (an estimate of prostate volume ≥ 30 cm(3)) was 35.3%. The prevalence of moderate-to-severe LUTS (IPSS≥8) was 19.9%. The prevalence of IPSS≥8 and an enlarged prostate on DRE was 13.3%. Although there is no universally agreed-upon definition of BPH/LUTS, making comparisons across populations difficult, BPH and/or LUTS appear to be quite common among older Ghanaian men. We found that after age standardization, the prevalence of DRE-detected enlarged prostate in Ghanaian men is higher than previously reported for American men, but the prevalence of LUTS was lower than previously reported for African Americans. Further studies are needed to confirm these findings and identify the risk factors for BPH in both Africans and African Americans.
Previous Knee Injury and Health-Related Quality of Life in Collegiate Athletes.
Lam, Kenneth C; Thomas, Steven St; Valier, Alison R Snyder; McLeod, Tamara C Valovich; Bay, R Curtis
2017-06-02
Patient-rated outcome measures (PROMs) capture changes that are important and meaningful to patients, such as health-related quality of life (HRQOL). Although group differences in HRQOL have been reported, little is known about the effect of injury history on HRQOL in collegiate athletes. To determine whether knee-specific function (International Knee Documentation Committee Subjective Knee Evaluation Form [IKDC]) and HRQOL (Short Form 12 [SF-12]) differs in collegiate athletes based on sex and the severity of a previous knee injury. Cross-sectional study. Athletic training facilities. Healthy collegiate athletes (n = 263) were grouped based on self-report of a previous knee injury: severe (n = 47), mild (n = 40), and no (n = 176) knee injury. Participants completed the IKDC and SF-12 during their preparticipation examinations. Generalized linear models were used to assess interactions and main effects of all scores. An interaction effect was observed for the SF-12 role physical subscale (P = .02), with men in the mild- and severe-injury groups reporting worse scores than men with no injury history. We noted a main effect for injury group for the IKDC total score (P < .001) and SF-12 physical functioning (P = .04) and role emotional (P = .04) subscales, with the severe-injury group reporting worse scores than the mild- and no-injury groups. No main effects of sex were reported (P > .05). Despite returning to full participation, collegiate athletes who previously sustained severe knee injuries tended to report worse knee-specific function and less ability to complete activities due to physical health. In addition, individuals with a history of severe knee injury tended to report more emotional concerns than athletes with a history of mild or no knee injury. Region-specific PROMs may be more sensitive in detecting deficits than generic PROMs after return to full participation. Researchers should investigate the role of PROMs, particularly region-specific PROMs, as potential screening tools for clinical care.
Unidentified emission features in the R Coronae Borealis star V854 Centauri
NASA Astrophysics Data System (ADS)
Oostrum, L. C.; Ochsendorf, B. B.; Kaper, L.; Tielens, A. G. G. M.
2018-02-01
During its 2012 decline, the R Coronae Borealis star (RCB) V854 Cen was spectroscopically monitored with X-shooter on the ESO Very Large Telescope. The obscured optical and near-infrared spectrum exhibits many narrow and several broad emission features, as previously observed. The envelope is spatially resolved along the slit and allows for a detailed study of the circumstellar material. In this Letter, we report on the properties of a number of unidentified visual emission features (UFs), including the detection of a new feature at 8692 Å. These UFs have been observed in the Red Rectangle (RR), but their chemical and physical nature is still a mystery. The previously known UFs behave similarly in the RR and in V854 Cen, but are not detected in six other observed RCBs. Some hydrogen might be required for the formation of their carrier(s). The λ8692 UF is present in all RCBs. Its carrier is likely of a carbonaceous molecular nature, presumably different from that of the other UFs.
Detection of Cercopithifilaria bainae in western Romania.
Andersson, Martin O; Chitimia-Dobler, Lidia
2017-11-01
Cercopithifilaria species are tick-transmitted filarial parasites of mammals. In Europe, three Cercopithifilaria spp. are known to parasitize dogs, all occurring mainly in the Mediterranean countries. In Romania, Cercopithifilaria bainae has been reported in a single dog in eastern Romania but the occurrence in other parts of the country is not known. To further elucidate the geographic distribution of Cercopithifilaria spp. infection, 544 ticks were collected from dogs in several locations across Romania. The presence of Cercopithifilaria spp. was investigated with real-time PCR. A single Dermacentor reticulatus female tick was found to be infected with Cercopithifilaria bainae. The finding in the present study is geographically separated from the previous finding in Romania by 800 km, as well as by the Carpathian mountain range. Hence, C. bainae is more geographically widespread in Romania than previously recognized. However, the single detection does suggest that infection is rather uncommon in Romanian dogs. Nevertheless, further studies on Cercopithifilaria spp. distribution and prevalence are needed.
Lightening the load: perceptual load impairs visual detection in typical adults but not in autism.
Remington, Anna M; Swettenham, John G; Lavie, Nilli
2012-05-01
Autism spectrum disorder (ASD) research portrays a mixed picture of attentional abilities with demonstrations of enhancements (e.g., superior visual search) and deficits (e.g., higher distractibility). Here we test a potential resolution derived from the Load Theory of Attention (e.g., Lavie, 2005). In Load Theory, distractor processing depends on the perceptual load of the task and as such can only be eliminated under high load that engages full capacity. We hypothesize that ASD involves enhanced perceptual capacity, leading to the superior performance and increased distractor processing previously reported. Using a signal-detection paradigm, we test this directly and demonstrate that, under higher levels of load, perceptual sensitivity was reduced in typical adults but not in adults with ASD. These findings confirm our hypothesis and offer a promising solution to the previous discrepancies by suggesting that increased distractor processing in ASD results not from a filtering deficit but from enhanced perceptual capacity.
Evolution of semilocal string networks. II. Velocity estimators
NASA Astrophysics Data System (ADS)
Lopez-Eiguren, A.; Urrestilla, J.; Achúcarro, A.; Avgoustidis, A.; Martins, C. J. A. P.
2017-07-01
We continue a comprehensive numerical study of semilocal string networks and their cosmological evolution. These can be thought of as hybrid networks comprised of (nontopological) string segments, whose core structure is similar to that of Abelian Higgs vortices, and whose ends have long-range interactions and behavior similar to that of global monopoles. Our study provides further evidence of a linear scaling regime, already reported in previous studies, for the typical length scale and velocity of the network. We introduce a new algorithm to identify the position of the segment cores. This allows us to determine the length and velocity of each individual segment and follow their evolution in time. We study the statistical distribution of segment lengths and velocities for radiation- and matter-dominated evolution in the regime where the strings are stable. Our segment detection algorithm gives higher length values than previous studies based on indirect detection methods. The statistical distribution shows no evidence of (anti)correlation between the speed and the length of the segments.
Callén, E; Tischkowitz, M D; Creus, A; Marcos, R; Bueren, J A; Casado, J A; Mathew, C G; Surrallés, J
2004-01-01
Fanconi anaemia is an autosomal recessive disease characterized by chromosome fragility, multiple congenital abnormalities, progressive bone marrow failure and a high predisposition to develop malignancies. Most of the Fanconi anaemia patients belong to complementation group FA-A due to mutations in the FANCA gene. This gene contains 43 exons along a 4.3-kb coding sequence with a very heterogeneous mutational spectrum that makes the mutation screening of FANCA a difficult task. In addition, as the FANCA gene is rich in Alu sequences, it was reported that Alu-mediated recombination led to large intragenic deletions that cannot be detected in heterozygous state by conventional PCR, SSCP analysis, or DNA sequencing. To overcome this problem, a method based on quantitative fluorescent multiplex PCR was proposed to detect intragenic deletions in FANCA involving the most frequently deleted exons (exons 5, 11, 17, 21 and 31). Here we apply the proposed method to detect intragenic deletions in 25 Spanish FA-A patients previously assigned to complementation group FA-A by FANCA cDNA retroviral transduction. A total of eight heterozygous deletions involving from one to more than 26 exons were detected. Thus, one third of the patients carried a large intragenic deletion that would have not been detected by conventional methods. These results are in agreement with previously published data and indicate that large intragenic deletions are one of the most frequent mutations leading to Fanconi anaemia. Consequently, this technology should be applied in future studies on FANCA to improve the mutation detection rate. Copyright 2003 S. Karger AG, Basel
Raman-spectroscopy-based chemical contaminant detection in milk powder
NASA Astrophysics Data System (ADS)
Dhakal, Sagar; Chao, Kuanglin; Qin, Jianwei; Kim, Moon S.
2015-05-01
Addition of edible and inedible chemical contaminants in food powders for purposes of economic benefit has become a recurring trend. In recent years, severe health issues have been reported due to consumption of food powders contaminated with chemical substances. This study examines the effect of spatial resolution used during spectral collection to select the optimal spatial resolution for detecting melamine in milk powder. Sample depth of 2mm, laser intensity of 200mw, and exposure time of 0.1s were previously determined as optimal experimental parameters for Raman imaging. Spatial resolution of 0.25mm was determined as the optimal resolution for acquiring spectral signal of melamine particles from a milk-melamine mixture sample. Using the optimal resolution of 0.25mm, sample depth of 2mm and laser intensity of 200mw obtained from previous study, spectral signal from 5 different concentration of milk-melamine mixture (1%, 0.5%, 0.1%, 0.05%, and 0.025%) were acquired to study the relationship between number of detected melamine pixels and corresponding sample concentration. The result shows that melamine concentration has a linear relation with detected number of melamine pixels with correlation coefficient of 0.99. It can be concluded that the quantitative analysis of powder mixture is dependent on many factors including physical characteristics of mixture, experimental parameters, and sample depth. The results obtained in this study are promising. We plan to apply the result obtained from this study to develop quantitative detection model for rapid screening of melamine in milk powder. This methodology can also be used for detection of other chemical contaminants in milk powders.
Horner, Patrick J; Wills, Gillian S; Reynolds, Rosy; Johnson, Anne M; Muir, David A; Winston, Alan; Broadbent, Andrew J; Parker, David; McClure, Myra O
2013-08-01
To investigate what factors influence the detection of Chlamydia trachomatis antibody following genital tract infection. One hundred and sixty-four women with a previous history of C trachomatis infection contributed to an earlier report on the performance of chlamydia antibody ELISA assays. We undertook further analysis to explore how chlamydia antibody assay sensitivity changes with time since infection. Chlamydia antibody was detected in more women soon after the last detection of chlamydia at the lower genital tract than at later times. This holds true for all tests, but the Anilabsystems IgG EIA, Medac pELISA plus ELISA and the Savyon SeroCT-IgG ELISA were less sensitive than the pgp3 ELISA and the Anilabsystems microimmunofluorescence (MIF) assay at all time points except during current infection. Fall in seropositivity in women generally occurred in the early weeks and months following the last episode of chlamydia infection. There was no clear pattern of further reduction in seropositivity after 6 months. Multiple previous episodes were associated with increased seropositivity in the pgp3 assay (two or more vs one, OR 19, p<0.001) and other tests, but the effect was significantly smaller for the Anilabs, Medac and SeroCT MOMP peptide ELISAs, but not for the MIF assay. Chlamydia antibody detection decreases with time since infection and this is most apparent in the first 6 months. In women who have had more than one infection, antibody remained detectable longer for all tests, but this was more marked for the pgp3 ELISA and MIF assay.
Aichivirus in Children with Diarrhea in Northern Italy.
Bergallo, Massimiliano; Galliano, Ilaria; Montanari, Paola; Rassu, Marco; Daprà, Valentina
2017-01-01
Since its discovery, Aichivirus (AiV) A has been detected, with an incidence of 0.9-4.1%, primarily when studying outbreaks of diarrhea in children or young adults. In this paper, we report the first detection of AiV in Piedmont, Italy, in pediatric patients. A total of 159 fecal specimens (from 96 males and 63 females) previously screened for rotaviruses, adenoviruses, noroviruses, human parechoviruses, saliviruses, and sapoviruses were collected from infants and children with acute gastroenteritis. The most commonly detected virus was norovirus GII (33.80%), fol lowed by rotavirus (21.30%), astrovirus (18.87%), boca virus (13.92%), sapovirus (10.90%), parechovirus (8%), norovirus GI (6.70%), adenovirus (1%), and salivirus (0.52%). Real-time polymerase chain reaction detected AiV A in 1 (0.62%) case subjects. AiV A was detected in monoinfection only in January. Our results indicate that AiV may be associated with a limited number of diarrhea cases in pediatric patients. © 2018 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Tamma, Venkata Ananth; Huang, Fei; Nowak, Derek; Kumar Wickramasinghe, H.
2016-06-01
We report on stimulated Raman spectroscopy and nanoscopy of molecules, excited without resonant electronic enhancement gain, and recorded using near field photon induced forces. Photon-induced interaction forces between the sharp metal coated silicon tip of an Atomic Force Microscope (AFM) and a sample resulting from stimulated Raman excitation were detected. We controlled the tip to sample spacing using the higher order flexural eigenmodes of the AFM cantilever, enabling the tip to come very close to the sample. As a result, the detection sensitivity was increased compared with previous work on Raman force microscopy. Raman vibrational spectra of azobenzene thiol and l-phenylalanine were measured and found to agree well with published results. Near-field force detection eliminates the need for far-field optical spectrometer detection. Recorded images show spatial resolution far below the optical diffraction limit. Further optimization and use of ultrafast pulsed lasers could push the detection sensitivity towards the single molecule limit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamma, Venkata Ananth; Huang, Fei; Kumar Wickramasinghe, H., E-mail: hkwick@uci.edu
We report on stimulated Raman spectroscopy and nanoscopy of molecules, excited without resonant electronic enhancement gain, and recorded using near field photon induced forces. Photon-induced interaction forces between the sharp metal coated silicon tip of an Atomic Force Microscope (AFM) and a sample resulting from stimulated Raman excitation were detected. We controlled the tip to sample spacing using the higher order flexural eigenmodes of the AFM cantilever, enabling the tip to come very close to the sample. As a result, the detection sensitivity was increased compared with previous work on Raman force microscopy. Raman vibrational spectra of azobenzene thiol andmore » l-phenylalanine were measured and found to agree well with published results. Near-field force detection eliminates the need for far-field optical spectrometer detection. Recorded images show spatial resolution far below the optical diffraction limit. Further optimization and use of ultrafast pulsed lasers could push the detection sensitivity towards the single molecule limit.« less
Bouvresse, Sophie; Socolovshi, Cristina; Berdjane, Zohra; Durand, Rémy; Izri, Arezki; Raoult, Didier; Chosidow, Olivier; Brouqui, Philippe
2011-12-01
The human body louse is the only known vector of Bartonella quintana. However, the presence of this bacterium has recently been detected in the head lice of homeless individuals and Nepalese slum children. Previous studies have reported the isolation of Acinetobacter baumannii from the body lice of homeless individuals. An epidemiological survey including 74 schools was conducted between 2008 and 2009 in Paris. After a first visual examination, the hair of children with suspected pediculosis was combed with a fine-tooth comb to collect live adult head lice. Molecular studies were performed on randomly selected DNA samples to detect B. quintana and A. baumannii by specific quantitative real-time PCR. Among a collection of 288 DNA samples, B. quintana was not detected, but A. baumannii was detected in 95 DNA samples (33%). Further study is needed to determine the significance of the finding of A. baumannii in head lice. 2011. Published by Elsevier Ltd. All rights reserved.
Constitutional trisomy 8 mosaicism syndrome: case report and review
Udayakumar, Achandira M.; Al-Kindy, Adila
2013-01-01
Trisomy 8 mosaicism (Warkany syndrome) is a rare viable condition with variable phenotypes, ranging from mild dysmorphic features to severe malformations. Karyotyping and fluorescence in-situ hybridization potentially help detecting this low mosaic clone to confirm the diagnosis of patients with classical and unusual clinical presentations. This report reviews few previous cases to describe our case - a boy who had trisomy 8 mosaicism with severe dysmorphic features, born to a consanguineous Arabic couple. This study concludes that careful cytogenetic diagnoses of trisomy 8 mosaicism is essential for appropriate management and follow up of this rare disorder. PMID:27625859
Constitutional trisomy 8 mosaicism syndrome: case report and review.
Udayakumar, Achandira M; Al-Kindy, Adila
2013-12-01
Trisomy 8 mosaicism (Warkany syndrome) is a rare viable condition with variable phenotypes, ranging from mild dysmorphic features to severe malformations. Karyotyping and fluorescence in-situ hybridization potentially help detecting this low mosaic clone to confirm the diagnosis of patients with classical and unusual clinical presentations. This report reviews few previous cases to describe our case - a boy who had trisomy 8 mosaicism with severe dysmorphic features, born to a consanguineous Arabic couple. This study concludes that careful cytogenetic diagnoses of trisomy 8 mosaicism is essential for appropriate management and follow up of this rare disorder.
Retina-V1 model of detectability across the visual field
Bradley, Chris; Abrams, Jared; Geisler, Wilson S.
2014-01-01
A practical model is proposed for predicting the detectability of targets at arbitrary locations in the visual field, in arbitrary gray scale backgrounds, and under photopic viewing conditions. The major factors incorporated into the model include (a) the optical point spread function of the eye, (b) local luminance gain control (Weber's law), (c) the sampling array of retinal ganglion cells, (d) orientation and spatial frequency–dependent contrast masking, (e) broadband contrast masking, and (f) efficient response pooling. The model is tested against previously reported threshold measurements on uniform backgrounds (the ModelFest data set and data from Foley, Varadharajan, Koh, & Farias, 2007) and against new measurements reported here for several ModelFest targets presented on uniform, 1/f noise, and natural backgrounds at retinal eccentricities ranging from 0° to 10°. Although the model has few free parameters, it is able to account quite well for all the threshold measurements. PMID:25336179
Comprehensive GMO detection using real-time PCR array: single-laboratory validation.
Mano, Junichi; Harada, Mioko; Takabatake, Reona; Furui, Satoshi; Kitta, Kazumi; Nakamura, Kosuke; Akiyama, Hiroshi; Teshima, Reiko; Noritake, Hiromichi; Hatano, Shuko; Futo, Satoshi; Minegishi, Yasutaka; Iizuka, Tayoshi
2012-01-01
We have developed a real-time PCR array method to comprehensively detect genetically modified (GM) organisms. In the method, genomic DNA extracted from an agricultural product is analyzed using various qualitative real-time PCR assays on a 96-well PCR plate, targeting for individual GM events, recombinant DNA (r-DNA) segments, taxon-specific DNAs, and donor organisms of the respective r-DNAs. In this article, we report the single-laboratory validation of both DNA extraction methods and component PCR assays constituting the real-time PCR array. We selected some DNA extraction methods for specified plant matrixes, i.e., maize flour, soybean flour, and ground canola seeds, then evaluated the DNA quantity, DNA fragmentation, and PCR inhibition of the resultant DNA extracts. For the component PCR assays, we evaluated the specificity and LOD. All DNA extraction methods and component PCR assays satisfied the criteria set on the basis of previous reports.
High-resolution two-photon spectroscopy of a 5 p56 p ←5 p6 transition of xenon
NASA Astrophysics Data System (ADS)
Altiere, Emily; Miller, Eric R.; Hayamizu, Tomohiro; Jones, David J.; Madison, Kirk W.; Momose, Takamasa
2018-01-01
We report high-resolution Doppler-free two-photon excitation spectroscopy of Xe from the ground state to the 5 p5(
Recent Developments on Autonomous Corrosion Protection Through Encapsulation
NASA Technical Reports Server (NTRS)
Li, W.; Buhrow, J. W.; Calle, L. M.; Gillis, M.; Blanton, M.; Hanna, J.; Rawlins, J.
2015-01-01
This paper concerns recent progress in the development of a multifunctional smart coating, based on microencapsulation, for the autonomous detection and control of corrosion. Microencapsulation has been validated and optimized to incorporate desired corrosion control functionalities, such as early corrosion detection and inhibition, through corrosion-initiated release of corrosion indicators and inhibitors, as well as self-healing agent release triggered by mechanical damage. While proof-of-concept results have been previously reported, more recent research and development efforts have concentrated on improving coating compatibility and synthesis procedure scalability, with a targeted goal of obtaining easily dispersible pigment-grade type microencapsulated materials. The recent progress has resulted in the development of pH-sensitive microparticles as a corrosion-triggered delivery system for corrosion indicators and inhibitors. The synthesis and early corrosion indication results obtained with coating formulations that incorporate these microparticles are reported. The early corrosion indicating results were obtained with color changing and with fluorescent indicators.
The Neural Representation of Consonant-Vowel Transitions in Adults Who Wear Hearing Aids
Tremblay, Kelly L.; Kalstein, Laura; Billings, Cuttis J.; Souza, Pamela E.
2006-01-01
Hearing aids help compensate for disorders of the ear by amplifying sound; however, their effectiveness also depends on the central auditory system's ability to represent and integrate spectral and temporal information delivered by the hearing aid. The authors report that the neural detection of time-varying acoustic cues contained in speech can be recorded in adult hearing aid users using the acoustic change complex (ACC). Seven adults (50–76 years) with mild to severe sensorineural hearing participated in the study. When presented with 2 identifiable consonant-vowel (CV) syllables (“shee” and “see”), the neural detection of CV transitions (as indicated by the presence of a P1-N1-P2 response) was different for each speech sound. More specifically, the latency of the evoked neural response coincided in time with the onset of the vowel, similar to the latency patterns the authors previously reported in normal-hearing listeners. PMID:16959736
Kärrman, Anna; Domingo, José L; Llebaria, Xavier; Nadal, Martí; Bigas, Esther; van Bavel, Bert; Lindström, Gunilla
2010-03-01
Perfluorinated compounds (PFCs) are global environmental pollutants that bioaccumulate in wildlife and humans. Laboratory experiments have revealed toxic effects such as delayed development, humoral suppression, and hepatotoxicity. Although numerous human blood levels have been reported, little is known about distribution in the human body. Knowledge about PFC distribution and accumulation in the human body is crucial to understanding uptake and subsequent effects as well as to conduct risk assessments. The present study reports PFC levels in human liver and breast milk from a general population living in Catalonia, Spain. Liver and milk levels are compared to previously reported levels in blood from the same geographic area as well as to other existing reports on human liver and milk levels in other countries. Human liver (n = 12) and milk (n = 10) samples were collected in 2007 and 2008 in Catalonia, Spain. Liver samples were taken postmortem from six males and six females aged 27-79 years. Milk samples were from healthy primipara women (30-39 years old). Both liver and milk were analyzed by solid-phase extraction and ultra-performance liquid chromatography tandem mass spectrometry. Six PFCs were detected in liver, with perfluorooctanesulfonate (PFOS, 26.6 ng/g wet weight) being the chemical with the highest mean concentration. Other PFCs such as perfluorohexanesulfonate (PFHxS), perfluorooctanoic acid (PFOA), and acids with chain lengths up to C11 were also detected, with mean levels ranging between 0.50 and 1.45 ng/g wet weight. On the other hand, PFOS and PFHxS were the only PFCs detected in human milk, with mean concentrations of 0.12 and 0.04 ng/mL, respectively. While milk concentrations were similar to reported levels from other countries, liver samples contained more PFCs above quantification limits and higher PFOS concentrations compared to the only two other reports found in the literature. Differences between the results of the present study and those concerning previous investigations can be due to declining levels of some PFCs, which have been reported for the USA. The relationship between PFC concentrations in human liver, milk, and blood was assessed using blood concentrations previously determined in Catalonia. Those levels resulted in liver/serum ratios of 1.7:1, 1.4:1, and 2.1:1 for PFOS, perfluorodecanoic acid, and perfluoroundecanoic acid, respectively. Accumulation in liver is suggested for PFOS and the perfluorocarboxylic acids with carbon chain lengths C9, C10, and C11. For PFOA and PFHxS, fivefold and 14-fold higher concentrations, respectively, were seen in serum as compared to liver. The mean concentration of PFOS and PFHxS in milk was only 0.8% and 0.6% of the reported mean serum level, respectively. The results of the present study show that several PFCs could be detected in human liver samples of subjects living in Tarragona. Concerning human milk, the mechanism by which PFCs are transferred from mother's blood to breast milk is still unclear. Considering that PFCs are strongly bound to the protein fraction in blood, the possibility of PFCs entering the milk and accumulating to levels observed in maternal plasma is limited. Interestingly, the potential accumulation difference for PFCs with different chain lengths might be of great importance for risk assessment. Continuing studies on the distribution of different PFCs in human tissue are therefore justified.
Rare Combination of Pathologies Causing Mitral Stenosis and Mitral Regurgitation: A Case Report.
Nair, Anupama K; Chowdhuri, Kuntal Roy; Radhakrishnan, Sitaraman; Iyer, Krishna S; Saxena, Manish
2018-01-01
A supramitral ring is a rare cause of mitral stenosis, while an isolated mitral valve cleft is a rare cause of congenital mitral regurgitation. Fortunately, both the lesions are known to have good outcomes after surgical correction. Although each is known to be associated with a variety of other structural heart defects, their coexistence has not been reported previously. We report a case of a three- and half-year-old boy detected to have a rare combination of supramitral ring producing severe mitral stenosis with a coexisting cleft in the anterior leaflet of mitral valve causing severe mitral regurgitation. The patient underwent successful surgical repair with resolution of both mitral stenosis and regurgitation.
Self-reported illness and household strategies for coping with health-care payments in Bangladesh
Gilmour, Stuart; Saito, Eiko; Sultana, Papia; Shibuya, Kenji
2013-01-01
Abstract Objective To investigate self-reported illness and household strategies for coping with payments for health care in a city in Bangladesh. Methods A cluster-sampled probability survey of 1593 households in the city of Rajshahi, Bangladesh, was conducted in 2011. Multilevel logistic regression – with adjustment for any clustering within households – was used to examine the risk of self-reported illness in the previous 30 days. A multilevel Poisson regression model, with adjustment for clustering within households and individuals, was used to explore factors potentially associated with the risk of health-care-related “distress” financing (e.g. paying for health care by borrowing, selling, reducing food expenditure, removing children from school or performing additional paid work). Findings According to the interviewees, about 45% of the surveyed individuals had suffered at least one episode of illness in the previous 30 days. The most frequently reported illnesses among children younger than 5 years and adults were common tropical infections and noncommunicable diseases, respectively. The risks of self-reported illness in the previous 30 days were relatively high for adults older than 44 years, women and members of households in the poorest quintile. Distress financing, which had been implemented to cover health-care payments associated with 13% of the reported episodes, was significantly associated with heart and liver disease, asthma, typhoid, inpatient care, the use of public outpatient facilities, and poverty at the household level. Conclusion Despite the subsidization of public health services in Bangladesh, high prevalences of distress financing – and illness – were detected in the surveyed, urban households. PMID:24052682
Polet, Michael; Van Gansbeke, Wim; Van Eenoo, Peter; Deventer, Koen
2016-07-01
Identification of anabolic androgenic steroids (AAS) is a vital issue in doping control and toxicology, and searching for metabolites with longer detection times remains an important task. Recently, a gas chromatography chemical ionization triple quadrupole mass spectrometry (GC-CI-MS/MS) method was introduced, and CI, in comparison with electron ionization (EI), proved to be capable of increasing the sensitivity significantly. In addition, correlations between AAS structure and fragmentation behavior could be revealed. This enables the search for previously unknown but expected metabolites by selection of their predicted transitions. The combination of both factors allows the setup of an efficient approach to search for new metabolites. The approach uses selected reaction monitoring which is inherently more sensitive than full scan or precursor ion scan. Additionally, structural information obtained from the structure specific CI fragmentation pattern facilitates metabolite identification. The procedure was demonstrated by a methandienone case study. Its metabolites have been studied extensively in the past, and this allowed an adequate evaluation of the efficiency of the approach. Thirty three metabolites were detected, including all relevant previously discovered metabolites. In our study, the previously reported long-term metabolite (18-nor-17β-hydroxymethyl,17α-methyl-androst-1,4,13-trien-3-one) could be detected up to 26 days by using GC-CI-MS/MS. The study proves the validity of the approach to search for metabolites of new synthetic AAS and new long-term metabolites of less studied AAS and illustrates the increase in sensitivity by using CI. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Giri, J A; Gregoresky, J; Silguero, P; García Messina, O; Planes, N
2001-01-01
Several studies had previously demonstrated the high sensitivity and specificity of JCV DNA detection in CSF by PCR. This paper reported the implementation of a simple PCR procedure to detect JCV in the CSF in a cohort of HIV-1 infected patients from Argentina. Years ago, the confirmatory diagnosis of this disease was made by in-situ hybridization or immunohistochemistry techniques on brain biopsies. The PCR procedure described here improves the diagnosis of PML because it is simple and noninvasive, and allows the differential diagnosis of PML from other neurological syndromes associated with AIDS. Many recent studies report a significant benefit of combined antiretroviral therapy on the survival of HIV patients without clear neurological improvements. A negative correlation has been described between the concentration of JCV in the CSF and survival time in HIV-1 infected patients, and the level of immune depression may influence JCV replication. This suggests that a single CSF JCV viral load determination during the course of PML disease progression may be of prognostic value for managing HIV patients.
Enzyme-linked small-molecule detection using split aptamer ligation.
Sharma, Ashwani K; Kent, Alexandra D; Heemstra, Jennifer M
2012-07-17
Here we report an aptamer-based analogue of the widely used sandwich enzyme-linked immunosorbent assay (ELISA). This assay utilizes the cocaine split aptamer, which is comprised of two DNA strands that only assemble in the presence of the target small molecule. One split aptamer fragment is immobilized on a microplate, then a test sample is added containing the second split aptamer fragment. If cocaine is present in the test sample, it directs assembly of the split aptamer and promotes a chemical ligation between azide and cyclooctyne functional groups appended to the termini of the split aptamer fragments. Ligation results in covalent attachment of biotin to the microplate and provides a colorimetric output upon conjugation to streptavidin-horseradish peroxidase. Using this assay, we demonstrate detection of cocaine at concentrations of 100 nM-100 μM in buffer and 1-100 μM human blood serum. The detection limit of 1 μM in serum represents an improvement of two orders of magnitude over previously reported split aptamer-based sensors and highlights the utility of covalently trapping split aptamer assembly events.
Search for cold gas in clusters with and without cooling flows
NASA Technical Reports Server (NTRS)
Grabelsky, D. A.; Ulmer, M. P.
1990-01-01
The dominant galaxy in each of approx. 40 clusters was studied using co-added Infrared Astronomy Satellite (IRAS) survey data, and 11 of these galaxies were observed for CO (J=1 to 0) emission with the 12 m telescope at Kitt Peak. Half of the galaxies in the sample are in clusters reported to have cooling flows while the other half are not. Six of the galaxies appear to have been detected by IRAS at fairly low flux levels, in addition to one previously known strong detection; all seven have reported cooling flows. No detectable CO emission (to 2 to 3 mK) was found in any of the 11 galaxies observed. Assuming accretion rates of approx. 100 Solar Mass yr(-1), the star formation rates and efficiencies in these galaxies must be quite high in order to render the CO undetectable. At the same time, the infrared luminosities of these galaxies is unremarkable, suggesting that the correlation between star formation efficiency and infrared luminosity found for spirals may not hold for cooling flows.
Larroche, C; Scieux, C; Honderlick, P; Piette, A M; Morinet, F; Blétry, O
2002-10-01
Reported here is the case of a patient who spontaneously recovered from hemophagocytic syndrome associated with acute B19 infection and concomitant Epstein-Barr virus reactivation. The previously healthy 37-year-old-man was hospitalized after 10 days of high fever, arthralgia and arthritis and was determined to have hemophagocytic syndrome. Immunoglobulin (Ig) M antibodies to Epstein-Barr virus (EBV) capsid antigen, early antigen and parvovirus B19 (B19) were found. B19 DNA and low-level EBV DNA were detected in bone marrow, serum and peripheral blood mononuclear cells. The patient recovered spontaneously without any treatment. Two months later anti-B19 IgG antibodies were detected, while at 9-month follow-up, anti-B19 IgM antibodies were no longer detectable and B19 DNA had disappeared from serum. To the best of our knowledge, this is the first report of spontaneous resolution of hemophagocytic syndrome associated with acute B19 infection and concomitant EBV reactivation in an otherwise healthy adult.
Acute heroin intoxication in a baby chronically exposed to cocaine and heroin: a case report
2011-01-01
Introduction Acute intoxication with drugs of abuse in children is often only the tip of the iceberg, actually hiding chronic exposure. Analysis using non-conventional matrices such as hair can provide long-term information about exposure to recreational drugs. Case presentation We report the case of a one-month-old Caucasian boy admitted to our pediatric emergency unit with respiratory distress and neurological abnormalities. A routine urine test was positive for opiates, suggesting an acute opiate ingestion. No other drugs of misuse, such as cocaine, cannabis, amphetamines or derivatives, were detected in the baby's urine. Subsequently, hair samples from the baby and the parents were collected to evaluate the possibility of chronic exposure to drug misuse by segmental analysis. Opiates and cocaine metabolites were detected in hair samples from the baby boy and his parents. Conclusions In light of these and previous results, we recommend hair analysis in babies and children from risky environments to detect exposure to heroin and other drug misuse, which could provide the basis for specific social and health interventions. PMID:21729296
Press, M F; Hung, G; Godolphin, W; Slamon, D J
1994-05-15
HER-2/neu oncogene amplification and overexpression of breast cancer tissue has been correlated with poor prognosis in women with both node-positive and node-negative disease. However, several studies have not confirmed this association. Review of these studies reveals the presence of considerable methodological variability including differences in study size, follow-up time, techniques and reagents. The majority of papers with clinical follow-up information are immunohistochemical studies using archival, paraffin-embedded breast cancers, and a variety of HER-2/neu antibodies have been used in these studies. Very little information, however, is available about the ability of the antibodies to detect overexpression following tissue processing for paraffin-embedding. Therefore, a series of antibodies, reported in the literature or commercially available, were evaluated to assess their sensitivity and specificity as immunohistochemical reagents. Paraffin-embedded samples of 187 breast cancers, previously characterized as frozen specimens for HER-2/neu amplification by Southern blot and for overexpression by Northern blot, Western blot, and immunohistochemistry, were used. Two multitumor paraffin-embedded tissue blocks were prepared from the previously analyzed breast cancers as a panel of cases to test a series of previously studied and/or commercially available anti-HER-2/neu antibodies. Immunohistochemical staining results obtained with 7 polyclonal and 21 monoclonal antibodies in sections from paraffin-embedded blocks of these breast cancers were compared. The ability of these antibodies to detect overexpression was extremely variable, providing an important explantation for the variable overexpression rate reported in the literature.
Going on with false beliefs: What if satisfaction of search was really suppression of recognition?
NASA Astrophysics Data System (ADS)
Mello-Thoms, Claudia; Trieu, Phuong Dung; Brennan, Patrick C.
2014-03-01
Satisfaction of search (SOS) is a well known phenomenon in radiology, in which the detection of one abnormality facilitates the neglect of other abnormalities. Over the years SOS has been thoroughly studied primarily in chest and in trauma, and it has been found to be an elusive effect, appearing in some settings but not in others. Unfortunately, very little is known about SOS in mammography. In this study we will explore SOS in breast cancer detection by considering a case set of digital mammograms as interpreted by breast radiologists. However, the primary goal of the study will be to challenge the core of the paradigm; for decades, many have associated SOS with incomplete search, but as Kundel has put eloquently when addressing the SPIE Medical Imaging in 2004 [1], "observers do not stop viewing when one abnormality has been found on an image with multiple abnormalities". What else could cause SOS then? According to our previous work, the first "perceived" abnormality reported by a radiologist has an influential role in the report of any other "perceived" abnormalities on the case, which supports the idea that perhaps SOS is caused a perceptual suppression of the recognition of different abnormalities. In other words, once the radiologist has made a first report (regardless of whether that first report is a TP or FP), detection and hence reporting of other abnormalities present in the case are greatly dependent on whether these associated abnormalities "fit the profile" of what has been already found.
Adaptive virus detection using filament-coupled antibodies.
Stone, Gregory P; Lin, Kelvin S; Haselton, Frederick R
2006-01-01
We recently reported the development of a filament-antibody recognition assay (FARA), in which the presence of virions in solution initiates the formation of enzyme-linked immunosorbent assay (ELISA)-like antibody complexes. The unique features of this assay are that processing is achieved by motion of a filament and that, in the presence of a virus, antibody-virus complexes are coupled to the filament at known locations. In this work, we combine the unique features of this assay with a 638-nm laser-based optical detector to enable adaptive control of virus detection. Integration of on-line fluorescence detection yields approximately a five-fold increase in signal-to-noise ratio (SNR) compared to the fluorescence detection method reported previously. A one-minute incubation with an M13K07 test virus is required to detect 10(10) virionsml, and 40 min was required to detect 10(8) virionsml. In tests of the components of an adaptive strategy, a 30-min virus (3.3 x 10(10) virionsml) incubation time, followed by repositioning the filament-captured virus either within the detecting antibody chamber, (20 microg ml) or within the virus chamber, found an increase in signal roughly proportional to the cumulative residence times in these chambers. Furthermore, cumulative fluorescence signals observed for a filament-captured virus after repeated positioning of the filament within the virus chamber are similar to those observed for a single long incubation time. The unique features of the FARA-like design combined with online optical detection to direct subsequent bioprocessing steps provides new flexibility for developing adaptive molecular recognition assays.
Zhang, Ning; Francis, Kevin P; Prakash, Arun; Ansaldi, Daniel
2013-04-01
A previous study reported the use of luminol for the detection of myeloperoxidase (MPO) activity using optical imaging in infiltrating neutrophils under inflammatory disease conditions. The detection is based on a photon-emitting reaction between luminol and an MPO metabolite. Because of tissue absorption and scattering, however, luminol-emitted blue light can be efficiently detected from superficial inflammatory foci only. In this study we report a chemiluminescence resonance energy transfer (CRET) methodology in which luminol-generated blue light excites nanoparticles to emit light in the near-infrared spectral range, resulting in remarkable improvement of MPO detectability in vivo. CRET caused a 37-fold increase in luminescence emission over luminol alone in detecting MPO activity in lung tissues after lipopolysaccharide challenge. We demonstrated a dependence of the chemiluminescent signal on MPO activity using MPO-deficient mice. In addition, co-administration of 4-aminobenzoic acid hydrazide (4-ABAH), an irreversible inhibitor of MPO, significantly attenuated luminescent emission from inflamed lungs. Inhibition of nitric oxide synthase with a nonspecific inhibitor, L-NAME, had no effect on luminol-mediated chemiluminescence production. Pretreatment of mice with MLN120B, a selective inhibitor of IKK-2, resulted in suppression of neutrophil infiltration to the lung tissues and reduction of MPO activity. We also demonstrated that CRET can effectively detect MPO activity at deep tissue tumor foci due to tumor development-associated neutrophil infiltration. We developed a sensitive MPO detection methodology that provides a means for visualizing and quantifying oxidative stress in deep tissue. This method is amenable to rapid evaluation of anti-inflammatory agents in animal models.
Fan, Daoqing; Shang, Changshuai; Gu, Wenling; Wang, Erkang; Dong, Shaojun
2017-08-09
Glutathione (GSH) plays crucial roles in various biological functions, the level alterations of which have been linked to varieties of diseases. Herein, we for the first time expanded the application of oxidase-like property of MnO 2 nanosheet (MnO 2 NS) to fluorescent substrates of peroxidase. Different from previously reported fluorescent quenching phenomena, we found that MnO 2 NS could not only largely quench the fluorescence of highly fluorescent Scopoletin (SC) but also surprisingly enhance that of nonfluorescent Amplex Red (AR) via oxidation reaction. If MnO 2 NS is premixed with GSH, it will be reduced to Mn 2+ and lose the oxidase-like property, accompanied by subsequent increase in SC's fluorescence and decrease in AR's. On the basis of the above mechanism, we construct the first MnO 2 NS-based ratiometric fluorescent sensor for ultrasensitive and selective detection of GSH. Notably, this ratiometric sensor is programmed by the cascade logic circuit (an INHIBIT gate cascade with a 1 to 2 decoder). And a linear relationship between ratiometric fluorescent intensities of the two substrates and logarithmic values of GSH's concentrations is obtained. The detection limit of GSH is as low as 6.7 nM, which is much lower than previous ratiometric fluorescent sensors, and the lowest MnO 2 NS-based fluorescent GSH sensor reported so far. Furthermore, this sensor is simple, label-free, and low-cost; it also presents excellent applicability in human serum samples.
Berruyer, M; Amiral, J; Ffrench, P; Belleville, J; Bastien, O; Clerc, J; Kassir, A; Estanove, S; Dechavanne, M
1993-05-01
Brief case histories of three patients aged 58, 38, and 44 years are reported. All underwent cardiovascular operations. Subsequently hemostasis test abnormalities developed between the seventh and eighth postoperative days after exposure to bovine thrombin used with fibrin glue. These were characterized by an increased activated partial thromboplastin time (64 to 147 seconds), prothrombin time (19 to 24 seconds), bovine thrombin time (> 120 seconds) and a markedly reduced factor V level (< 10% in two patients and 16% in the third patient). A patient plasma dilution of 1 in 200 with a normal plasma pool was necessary to correct bovine thrombin time. No fast-acting or progressive inhibitor against factor V could be detected by coagulation tests, and fresh frozen plasma perfusion had no effect. Plasmapheresis was performed preventatively to avoid bleeding, and factor V levels stabilized at around 50% after two to four exchanges. Immunologic studies showed that the inhibitors were directed not only against bovine factors but also against human ones. Therefore factor V decrease could have been the result of rapid clearance from the circulation of complexes formed with a nonneutralizing inhibitor that is not detected by clotting tests. These antibodies were purified by standard methods and immunoaffinity. Fast immunization could be explained by a prior sensitization to bovine thrombin exposure during previous operations. It is suggested that bovine thrombin used with fibrin glue contains small amounts of factor V and may be responsible for these abnormalities. This is in agreement with previous literature reports. However, these described neutralizing factor V inhibitors, which were easily detected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, W. D.
In order to appropriately model and predict the chemical integrity and performance of cementitious materials used for waste immobilization at the Savannah River Site (SRS), it is critical to understand the I-129 solubility and distribution within the tank farm. Iodine in radioactive waste and in environmental media is typically highly mobile and long lived. Iodine is ubiquitous in SRS tank waste and waste forms. The iodine is assumed to be soluble and present at low levels in Performance Assessments (PAs) for SRS Tank Farms, and is one of the dose drivers in the PAs for both the SRS Salt Disposalmore » Facility (SDF) and the H-Area Tank Farm (HTF). Analysis of tank waste samples is critical to understanding the Tank Farm iodine inventory and reducing disposal uncertainty. Higher than expected iodine levels have recently been observed in residual solids isolated from some SRS tanks prior to closure, indicating uncertainty regarding the chemical species involved. If the iodine inventory uncertainty is larger than anticipated, future work may be necessary to reduce the uncertainty. This memorandum satisfies a portion of the work scope identified in Task Plan SRNL-RP-2016-00651. A separate memorandum issued previously, reported historical unpublished I-129 data, a significant portion of which was below detectable analytical limits. This memorandum includes iodine and general chemical analysis results for six archived SRNL samples which were previously reported to have I-129 concentrations below detectable limits. Lower sample dilution factors were used for the current analyses in order to obtain concentrations above detection. The samples analyzed included surface and depth samples from SRS tanks 30, 32, and 39.« less
Design rules for quantum imaging devices: experimental progress using CMOS single-photon detectors
NASA Astrophysics Data System (ADS)
Charbon, Edoardo; Gunther, Neil J.; Boiko, Dmitri L.; Beretta, Giordano B.
2006-08-01
We continue our previous program1 where we introduced a set of quantum-based design rules directed at quantum engineers who design single-photon quantum communications and quantum imaging devices. Here, we report on experimental progress using SPAD (single photon avalanche diode) arrays of our design and fabricated in CMOS (complementary metal oxide semiconductor) technology. Emerging high-resolution imaging techniques based on SPAD arrays have proven useful in a variety of disciplines including bio-fluorescence microscopy and 3D vision systems. They have also been particularly successful for intra-chip optical communications implemented entirely in CMOS technology. More importantly for our purposes, a very low dark count allows SPADs to detect rare photon events with a high dynamic range and high signal-to-noise ratio. Our CMOS SPADs support multi-channel detection of photon arrivals with picosecond accuracy, several million times per second, due to a very short detection cycle. The tiny chip area means they are suitable for highly miniaturized quantum imaging devices and that is how we employ them in this paper. Our quantum path integral analysis of the Young-Afshar-Wheeler interferometer showed that Bohr's complementarity principle was not violated due the previously overlooked effect of photon bifurcation within the lens--a phenomenon consistent with our quantum design rules--which accounts for the loss of which-path information in the presence of interference. In this paper, we report on our progress toward the construction of quantitative design rules as well as some proposed tests for quantum imaging devices using entangled photon sources with our SPAD imager.
External validation of urinary PCA3-based nomograms to individually predict prostate biopsy outcome.
Auprich, Marco; Haese, Alexander; Walz, Jochen; Pummer, Karl; de la Taille, Alexandre; Graefen, Markus; de Reijke, Theo; Fisch, Margit; Kil, Paul; Gontero, Paolo; Irani, Jacques; Chun, Felix K-H
2010-11-01
Prior to safely adopting risk stratification tools, their performance must be tested in an external patient cohort. To assess accuracy and generalizability of previously reported, internally validated, prebiopsy prostate cancer antigen 3 (PCA3) gene-based nomograms when applied to a large, external, European cohort of men at risk of prostate cancer (PCa). Biopsy data, including urinary PCA3 score, were available for 621 men at risk of PCa who were participating in a European multi-institutional study. All patients underwent a ≥10-core prostate biopsy. Biopsy indication was based on suspicious digital rectal examination, persistently elevated prostate-specific antigen level (2.5-10 ng/ml) and/or suspicious histology (atypical small acinar proliferation of the prostate, >/= two cores affected by high-grade prostatic intraepithelial neoplasia in first set of biopsies). PCA3 scores were assessed using the Progensa assay (Gen-Probe Inc, San Diego, CA, USA). According to the previously reported nomograms, different PCA3 score codings were used. The probability of a positive biopsy was calculated using previously published logistic regression coefficients. Predicted outcomes were compared to the actual biopsy results. Accuracy was calculated using the area under the curve as a measure of discrimination; calibration was explored graphically. Biopsy-confirmed PCa was detected in 255 (41.1%) men. Median PCA3 score of biopsy-negative versus biopsy-positive men was 20 versus 48 in the total cohort, 17 versus 47 at initial biopsy, and 37 versus 53 at repeat biopsy (all p≤0.002). External validation of all four previously reported PCA3-based nomograms demonstrated equally high accuracy (0.73-0.75) and excellent calibration. The main limitations of the study reside in its early detection setting, referral scenario, and participation of only tertiary-care centers. In accordance with the original publication, previously developed PCA3-based nomograms achieved high accuracy and sufficient calibration. These novel nomograms represent robust tools and are thus generalizable to European men at risk of harboring PCa. Consequently, in presence of a PCA3 score, these nomograms may be safely used to assist clinicians when prostate biopsy is contemplated. Copyright © 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Johnsen, Jill M.; Fletcher, Shelley N.; Huston, Haley; Roberge, Sarah; Martin, Beth K.; Kircher, Martin; Josephson, Neil C.; Shendure, Jay; Ruuska, Sarah; Koerper, Marion A.; Morales, Jaime; Pierce, Glenn F.; Aschman, Diane J.
2017-01-01
Hemophilia A and B are rare, X-linked bleeding disorders. My Life, Our Future (MLOF) is a collaborative project established to genotype and study hemophilia. Patients were enrolled at US hemophilia treatment centers (HTCs). Genotyping was performed centrally using next-generation sequencing (NGS) with an approach that detected common F8 gene inversions simultaneously with F8 and F9 gene sequencing followed by confirmation using standard genotyping methods. Sixty-nine HTCs enrolled the first 3000 patients in under 3 years. Clinically reportable DNA variants were detected in 98.1% (2357/2401) of hemophilia A and 99.3% (595/599) of hemophilia B patients. Of the 924 unique variants found, 285 were novel. Predicted gene-disrupting variants were common in severe disease; missense variants predominated in mild–moderate disease. Novel DNA variants accounted for ∼30% of variants found and were detected continuously throughout the project, indicating that additional variation likely remains undiscovered. The NGS approach detected >1 reportable variants in 36 patients (10 females), a finding with potential clinical implications. NGS also detected incidental variants unlikely to cause disease, including 11 variants previously reported in hemophilia. Although these genes are thought to be conserved, our findings support caution in interpretation of new variants. In summary, MLOF has contributed significantly toward variant annotation in the F8 and F9 genes. In the near future, investigators will be able to access MLOF data and repository samples for research to advance our understanding of hemophilia. PMID:29296726
Decreased visual detection during subliminal stimulation.
Bareither, Isabelle; Villringer, Arno; Busch, Niko A
2014-10-17
What is the perceptual fate of invisible stimuli-are they processed at all and does their processing have consequences for the perception of other stimuli? As has been shown previously in the somatosensory system, even stimuli that are too weak to be consciously detected can influence our perception: Subliminal stimulation impairs perception of near-threshold stimuli and causes a functional deactivation in the somatosensory cortex. In a recent study, we showed that subliminal visual stimuli lead to similar responses, indicated by an increase in alpha-band power as measured with electroencephalography (EEG). In the current study, we investigated whether a behavioral inhibitory mechanism also exists within the visual system. We tested the detection of peripheral visual target stimuli under three different conditions: Target stimuli were presented alone or embedded in a concurrent train of subliminal stimuli either at the same location as the target or in the opposite hemifield. Subliminal stimuli were invisible due to their low contrast, not due to a masking procedure. We demonstrate that target detection was impaired by the subliminal stimuli, but only when they were presented at the same location as the target. This finding indicates that subliminal, low-intensity stimuli induce a similar inhibitory effect in the visual system as has been observed in the somatosensory system. In line with previous reports, we propose that the function underlying this effect is the inhibition of spurious noise by the visual system. © 2014 ARVO.
Response Times to Gustatory-Olfactory Flavor Mixtures: Role of Congruence.
Shepard, Timothy G; Veldhuizen, Maria G; Marks, Lawrence E
2015-10-01
A mixture of perceptually congruent gustatory and olfactory flavorants (sucrose and citral) was previously shown to be detected faster than predicted by a model of probability summation that assumes stochastically independent processing of the individual gustatory and olfactory signals. This outcome suggests substantial integration of the signals. Does substantial integration also characterize responses to mixtures of incongruent flavorants? Here, we report simple response times (RTs) to detect brief pulses of 3 possible flavorants: monosodium glutamate, MSG (gustatory: "umami" quality), citral (olfactory: citrus quality), and a mixture of MSG and citral (gustatory-olfactory). Each stimulus (and, on a fraction of trials, water) was presented orally through a computer-operated, automated flow system, and subjects were instructed to press a button as soon as they detected any of the 3 non-water stimuli. Unlike responses previously found to the congruent mixture of sucrose and citral, responses here to the incongruent mixture of MSG and citral took significantly longer (RTs were greater) and showed lower detection rates than the values predicted by probability summation. This outcome suggests that the integration of gustatory and olfactory flavor signals is less extensive when the component flavors are perceptually incongruent rather than congruent, perhaps because incongruent flavors are less familiar. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Radio detections of southern ultracool dwarfs
NASA Astrophysics Data System (ADS)
Lynch, C.; Murphy, T.; Ravi, V.; Hobbs, G.; Lo, K.; Ward, C.
2016-04-01
We report the results of a volume-limited survey using the Australia Telescope Compact Array to search for transient and quiescent radio emission from 15 Southern hemisphere ultracool dwarfs. We detect radio emission from 2MASSW J0004348-404405 increasing the number of radio loud ultracool dwarfs to 22. We also observe radio emission from 2MASS J10481463-3956062 and 2MASSI J0339352-352544, two sources with previous radio detections. The radio emission from the three detected sources shows no variability or flare emission. Modelling this quiescent emission we find that it is consistent with optically thin gyrosynchrotron emission from a magnetosphere with an emitting region radius of (1-2)R*, magnetic field inclination 20°-80°, field strength ˜10-200 G, and power-law electron density ˜104-108 cm-3. Additionally, we place upper limits on four ultracool dwarfs with no previous radio observations. This increases the number of ultracool dwarfs studied at radio frequencies to 222. Analysing general trends of the radio emission for this sample of 15 sources, we find that the radio activity increases for later spectral types and more rapidly rotating objects. Furthermore, comparing the ratio of the radio to X-ray luminosities for these sources, we find 2MASS J10481463-3956062 and 2MASSI J0339352-352544 violate the Güdel-Benz relation by more than two orders of magnitude.
On the Ubiquity of Molecular Anions in the Dense Interstellar Medium
NASA Technical Reports Server (NTRS)
Cordiner, M. A.; Buckle, J. V.; Wirstroem, E. S.; Olofsson, A. O. H.; Charnley, S. B.
2013-01-01
Results are presented from a survey for molecular anions in seven nearby Galactic star-forming cores and molecular clouds. The hydrocarbon anion C6H(-) is detected in all seven target sources, including four sources where no anions have been previously detected: L1172, L1389, L1495B, and TMC-1C. The C6H(-) /C6H column density ratio is approx. > 1.0% in every source, with a mean value of 3.0% (and standard deviation 0.92%). Combined with previous detections, our results show that anions are ubiquitous in dense clouds wherever C6H is present. The C6H(-)/C6H ratio is found to show a positive correlation with molecular hydrogen number density, and with the apparent age of the cloud.We also report the first detection of C4H(-) in TMC-1 (at 4.8 sigma confidence), and derive an anion-to-neutral ratio C4H(-) /C4H = (1.2 +/- 0.4)×10(exp -5)(= 0.0012% +/- 0.0004%). Such a low value compared with C6H(-) highlights the need for a revised radiative electron attachment rate for C4H. Chemical model calculations show that the observed C4H(-) could be produced as a result of reactions of oxygen atoms with C5H(-) and C6H(-).
Diagnosis and management of dementia with Lewy bodies
Boeve, Bradley F.; Dickson, Dennis W.; Halliday, Glenda; Taylor, John-Paul; Weintraub, Daniel; Aarsland, Dag; Galvin, James; Attems, Johannes; Ballard, Clive G.; Bayston, Ashley; Beach, Thomas G.; Blanc, Frédéric; Bohnen, Nicolaas; Bonanni, Laura; Bras, Jose; Brundin, Patrik; Burn, David; Chen-Plotkin, Alice; Duda, John E.; El-Agnaf, Omar; Feldman, Howard; Ferman, Tanis J.; ffytche, Dominic; Fujishiro, Hiroshige; Galasko, Douglas; Goldman, Jennifer G.; Gomperts, Stephen N.; Graff-Radford, Neill R.; Honig, Lawrence S.; Iranzo, Alex; Kantarci, Kejal; Kaufer, Daniel; Kukull, Walter; Lee, Virginia M.Y.; Leverenz, James B.; Lewis, Simon; Lippa, Carol; Lunde, Angela; Masellis, Mario; Masliah, Eliezer; McLean, Pamela; Mollenhauer, Brit; Montine, Thomas J.; Moreno, Emilio; Mori, Etsuro; Murray, Melissa; O'Brien, John T.; Orimo, Sotoshi; Postuma, Ronald B.; Ramaswamy, Shankar; Ross, Owen A.; Salmon, David P.; Singleton, Andrew; Taylor, Angela; Thomas, Alan; Tiraboschi, Pietro; Toledo, Jon B.; Trojanowski, John Q.; Tsuang, Debby; Walker, Zuzana; Yamada, Masahito; Kosaka, Kenji
2017-01-01
The Dementia with Lewy Bodies (DLB) Consortium has refined its recommendations about the clinical and pathologic diagnosis of DLB, updating the previous report, which has been in widespread use for the last decade. The revised DLB consensus criteria now distinguish clearly between clinical features and diagnostic biomarkers, and give guidance about optimal methods to establish and interpret these. Substantial new information has been incorporated about previously reported aspects of DLB, with increased diagnostic weighting given to REM sleep behavior disorder and 123iodine-metaiodobenzylguanidine (MIBG) myocardial scintigraphy. The diagnostic role of other neuroimaging, electrophysiologic, and laboratory investigations is also described. Minor modifications to pathologic methods and criteria are recommended to take account of Alzheimer disease neuropathologic change, to add previously omitted Lewy-related pathology categories, and to include assessments for substantia nigra neuronal loss. Recommendations about clinical management are largely based upon expert opinion since randomized controlled trials in DLB are few. Substantial progress has been made since the previous report in the detection and recognition of DLB as a common and important clinical disorder. During that period it has been incorporated into DSM-5, as major neurocognitive disorder with Lewy bodies. There remains a pressing need to understand the underlying neurobiology and pathophysiology of DLB, to develop and deliver clinical trials with both symptomatic and disease-modifying agents, and to help patients and carers worldwide to inform themselves about the disease, its prognosis, best available treatments, ongoing research, and how to get adequate support. PMID:28592453
Development of the first-mention bias*
HARTSHORNE, JOSHUA K.; NAPPA, REBECCA; SNEDEKER, JESSE
2015-01-01
In many contexts, pronouns are interpreted as referring to the character mentioned first in the previous sentence, an effect called the ‘first-mention bias’. While adults can rapidly use the first-mention bias to guide pronoun interpretation, it is unclear when this bias emerges during development. Curiously, experiments with children between two and three years old show successful use of order of mention, while experiments with older children (four to five years old) do not. While this could suggest U-shaped development, it could also reflect differences in the methodologies employed. We show that children can indeed use first-mention information, but do so too slowly to have been detected in previous work reporting null results. Comparison across the present and previously published studies suggests that the speed at which children deploy first-mention information increases greatly during the preschool years. PMID:24735525
Molecular Evolution of Enterovirus 68 Detected in the Philippines
Imamura, Tadatsugu; Suzuki, Akira; Lupisan, Socorro; Okamoto, Michiko; Aniceto, Rapunzel; Egos, Rutchie J.; Daya, Edgardo E.; Tamaki, Raita; Saito, Mariko; Fuji, Naoko; Roy, Chandra Nath; Opinion, Jaime M.; Santo, Arlene V.; Macalalad, Noel G.; Tandoc, Amado; Sombrero, Lydia; Olveda, Remigio; Oshitani, Hitoshi
2013-01-01
Background Detection of Enterovirus 68 (EV68) has recently been increased. However, underlying evolutionary mechanism of this increasing trend is not fully understood. Methods Nasopharyngeal swabs were collected from 5,240 patients with acute respiratory infections in the Philippines from June 2009 to December 2011. EV68 was detected by polymerase chain reaction (PCR) targeting for 5′ untranslated region (5′UTR), viral protein 1 (VP1), and VP4/VP2. Phylogenetic trees were generated using the obtained sequences. Results Of the 5,240 tested samples, 12 EV68 positive cases were detected between August and December in 2011 (detection rate, 0.23%). The detection rate was higher among inpatients than outpatients (p<0.0001). Among VP1 sequences detected from 7 patients in 2011, 5 in lineage 2 were diverged from those detected in the Philippines in 2008, however, 2 in lineage 3 were not diverged from strains detected in the Philippines in 2008 but closely associated with strains detected in the United States. Combined with our previous report, EV68 occurrences were observed twice in the Philippines within the last four years. Conclusions EV68 detections might be occurring in cyclic patterns, and viruses might have been maintained in the community while some strains might have been newly introduced. PMID:24073203
Iwasaki, Yoichiro; Misumi, Masato; Nakamiya, Toshiyuki
2013-06-17
We have already proposed a method for detecting vehicle positions and their movements (henceforth referred to as "our previous method") using thermal images taken with an infrared thermal camera. Our experiments have shown that our previous method detects vehicles robustly under four different environmental conditions which involve poor visibility conditions in snow and thick fog. Our previous method uses the windshield and its surroundings as the target of the Viola-Jones detector. Some experiments in winter show that the vehicle detection accuracy decreases because the temperatures of many windshields approximate those of the exterior of the windshields. In this paper, we propose a new vehicle detection method (henceforth referred to as "our new method"). Our new method detects vehicles based on tires' thermal energy reflection. We have done experiments using three series of thermal images for which the vehicle detection accuracies of our previous method are low. Our new method detects 1,417 vehicles (92.8%) out of 1,527 vehicles, and the number of false detection is 52 in total. Therefore, by combining our two methods, high vehicle detection accuracies are maintained under various environmental conditions. Finally, we apply the traffic information obtained by our two methods to traffic flow automatic monitoring, and show the effectiveness of our proposal.
Direct Imaging Detection of Methane in the Atmosphere of GJ 504 b
NASA Technical Reports Server (NTRS)
Janson, Markus; Brandt, Timothy; Kuzuhara, Masayuki; Spiegel, David; Thalmann, Christian; Currie, Thayne; Bonnefoy, Mickael; Zimmerman, Neil; Sorahana, Satoko; Kotani, Takayuki;
2013-01-01
Most exoplanets detected by direct imaging so far have been characterized by relatively hot (approximately greater than1000 K) and cloudy atmospheres. A surprising feature in some of their atmospheres has been a distinct lack of methane, possibly implying non-equilibrium chemistry. Recently, we reported the discovery of a planetary companion to the Sun-like star GJ 504 using Subaru/HiCIAO within the SEEDS survey. The planet is substantially colder (less than 600 K) than previously imaged planets, and has indications of fewer clouds, which implies that it represents a new class of planetary atmospheres with expected similarities to late T-type brown dwarfs in the same temperature range. If so, one might also expect the presence of significant methane absorption, which is characteristic of such objects. Here, we report the detection of deep methane absorption in the atmosphere of GJ 504 b, using the Spectral Differential Imaging mode of HiCIAO to distinguish the absorption feature around 1.6 micrometers. We also report updated JHK photometry based on new K(sub s)-band data and a re-analysis of the existing data. The results support the notion that GJ 504 b has atmospheric properties distinct from other imaged exoplanets, and will become a useful reference object for future planets in the same temperature range.
Levofloxacin-Induced Acute Immune-Mediated Thrombocytopenia of Rapid-Onset.
Shih, Andrew W; Lam, Andy S; Warkentin, Theodore E
2018-04-01
Drug-induced immune thrombocytopenia (D-ITP) typically occurs after the patient has been receiving the implicated drug for at least 1 week, due to newly forming drug-dependent antibodies ("typical-onset" D-ITP). A "rapid-onset" form of D-ITP can occur when previous sensitization has occurred, where antibodies have thus already been formed, and a precipitous platelet count fall occurs upon reexposure. Typical-onset D-ITP has been reported after levofloxacin, but the rapid-onset form with a well-documented previous exposure has not been described. We report a 76-year-old male treated with levofloxacin for acute exacerbation of chronic obstructive pulmonary disease. After a single 750 mg oral dose of levofloxacin, his platelet count fell from 187 to 5 × 10 9 /L (nadir) over 4 days. Other causes of thrombocytopenia were ruled out. He had received a previous course of levofloxacin 6 months earlier. Discontinuation of levofloxacin and treatment with intravenous immunoglobulin and dexamethasone resulted in platelet count recovery. Levofloxacin-dependent antibodies were not detectable, consistent with the known low sensitivity of laboratory tests for drug-dependent antibodies, presumably indicating antibodies against levofloxacin metabolites, as is indirectly supported by the abrupt but relatively slow platelet count decline observed. This case illustrates a rapid-onset presentation of levofloxacin-induced D-ITP in the setting of previous drug exposure.
A ppb level sensitive sensor for atmospheric methane detection
NASA Astrophysics Data System (ADS)
Xia, Jinbao; Zhu, Feng; Zhang, Sasa; Kolomenskii, Alexandre; Schuessler, Hans
2017-11-01
A high sensitivity sensor, combining a multipass cell and wavelength modulation spectroscopy in the near infrared spectral region was designed and implemented for trace gas detection. The effective length of the multipass cell was about 290 meters. The developed spectroscopic technique demonstrates an improved sensitivity of methane in ambient air and a relatively short detection time compared to previously reported sensors. Home-built electronics and software were employed for diode laser frequency modulation, signal lock-in detection and processing. A dual beam scheme and a balanced photo-detector were implemented to suppress the intensity modulation and noise for better detection sensitivity. The performance of the sensor was evaluated in a series of measurements ranging from three hours to two days. The average methane concentration measured in ambient air was 2.01 ppm with a relative error of ± 2.5%. With Allan deviation analysis, it was found that the methane detection limit of 1.2 ppb was achieved in 650 s. The developed sensor is compact and portable, and thus it is well suited for field measurements of methane and other trace gases.
Amperometric immunosensor for rapid detection of Mycobacterium tuberculosis
NASA Astrophysics Data System (ADS)
Hiraiwa, Morgan; Kim, Jong-Hoon; Lee, Hyun-Boo; Inoue, Shinnosuke; Becker, Annie L.; Weigel, Kris M.; Cangelosi, Gerard A.; Lee, Kyong-Hoon; Chung, Jae-Hyun
2015-05-01
Tuberculosis (TB) has been a major public health problem, which can be better controlled by using accurate and rapid diagnosis in low-resource settings. A simple, portable, and sensitive detection method is required for point-of-care (POC) settings. This paper studies an amperometric biosensor using a microtip immunoassay for a rapid and low-cost detection of Mycobacterium tuberculosis (MTB) in sputum. MTB in sputum is specifically captured on the functionalized microtip surface and detected by electric current. According to the numerical study, the current signal on the microtip surface is linearly changed with increasing immersion depth. Using a reference microtip, the immersion depth is compensated for a sensing microtip. On the microtip surface, target bacteria are concentrated and organized by a coffee-ring effect, which amplifies the electric current. To enhance the signal-to-noise ratio, both the sample processing and rinsing steps are presented with the use of deionized water as a medium for the amperometric measurement. When applied to cultured MTB cells spiked into human sputum, the detection limit was 100 CFU mL-1, comparable to a more labor-intensive fluorescence detection method reported previously.
Physical Conditions in Low Ionization Regions of the Orion Nebula
NASA Technical Reports Server (NTRS)
Baldwin, J. A.; Crotts, A.; DuFour, R. J.; Ferland, G. J.; Heathcote, S.; Hester, J. J.; Korista, K. T.; Martin, P. J.; ODell, C. R.
1996-01-01
We reexamine the spectroscopic underpinnings of recent claims that low ionization (O(I)) and (Fe(II)) lines from the Orion H(II) region are produced in a region where the iron-carrying grains have been destroyed and the electron density is surprisingly high. Our new HST and CTIO observations show that previous reported detections of(O(I)) lambda 5577 were strongly affected by telluric emission. Our line limits consistent with a moderate density (approx. 10(exp 4)/cu. cm photoionized gas. We show that a previously proposed model of the Orion H(II) region reproduces the observed (O(I)) and (Fe(II)) spectrum. These lines are fully consistent with formation in a moderate density dusty region.
Built-Up Area Feature Extraction: Second Year Technical Progress Report
1990-02-01
Contract DACA 72-87-C-001. During this year we have built on previous research, in road network extraction and in the detection and delineation of buildings...methods to perform stereo analysis using loosely coupled techniques where comparison is deferred until each method has performed a complete estimate...or missing information. A course of action may be suggested to the user depending on the error. Although the checks do not guarantee the correctness
Crimean Congo Hemorrhagic Fever Virus and Alkhurma (Alkhumra) Virus in Ticks in Djibouti
Horton, Katherine C.; Fahmy, Nermeen T.; Watany, Noha; Zayed, Alia; Mohamed, Abro; Ahmed, Ammar Abdo; Rollin, Pierre E.; Dueger, Erica L.
2017-01-01
Crimean Congo hemorrhagic fever virus and Alkhumra virus, not previously reported in Djibouti, were detected among 141 (infection rate =15.7 per 100, 95% CI: 13.4–18.1) tick pools from 81 (37%) cattle and 2 (infection rate = 0.2 per 100, 95% CI: 0.0–0.7) tick pools from 2 (1%) cattle, respectively, collected at an abattoir in 2010 and 2011. PMID:27508862
Early MESSENGER Results for Less Abundant or Weakly Emitting Species in Mercury's Exosphere
NASA Technical Reports Server (NTRS)
Vervack, Ronald J., Jr.; McClintock, William E.; Killen, Rosemary M.; Sprague, Ann L.; Burger, Matthew H.; Merkel, Aimee W.; Sarantos, Menelaos
2011-01-01
Now that the Messenger spacecraft is in orbit about Mercury, the extended observing time enables searches for exospheric species that are less abundant or weakly emitting compared with those for which emission has previously been detected. Many of these species cannot be observed from the ground because of terrestrial atmospheric absorption. We report here on the status of MESSENGER orbital-phase searches for additional species in Mercury's exosphere.
Common germline polymorphisms associated with breast cancer-specific survival.
Pirie, Ailith; Guo, Qi; Kraft, Peter; Canisius, Sander; Eccles, Diana M; Rahman, Nazneen; Nevanlinna, Heli; Chen, Constance; Khan, Sofia; Tyrer, Jonathan; Bolla, Manjeet K; Wang, Qin; Dennis, Joe; Michailidou, Kyriaki; Lush, Michael; Dunning, Alison M; Shah, Mitul; Czene, Kamila; Darabi, Hatef; Eriksson, Mikael; Lambrechts, Dieter; Weltens, Caroline; Leunen, Karin; van Ongeval, Chantal; Nordestgaard, Børge G; Nielsen, Sune F; Flyger, Henrik; Rudolph, Anja; Seibold, Petra; Flesch-Janys, Dieter; Blomqvist, Carl; Aittomäki, Kristiina; Fagerholm, Rainer; Muranen, Taru A; Olsen, Janet E; Hallberg, Emily; Vachon, Celine; Knight, Julia A; Glendon, Gord; Mulligan, Anna Marie; Broeks, Annegien; Cornelissen, Sten; Haiman, Christopher A; Henderson, Brian E; Schumacher, Frederick; Le Marchand, Loic; Hopper, John L; Tsimiklis, Helen; Apicella, Carmel; Southey, Melissa C; Cross, Simon S; Reed, Malcolm Wr; Giles, Graham G; Milne, Roger L; McLean, Catriona; Winqvist, Robert; Pylkäs, Katri; Jukkola-Vuorinen, Arja; Grip, Mervi; Hooning, Maartje J; Hollestelle, Antoinette; Martens, John Wm; van den Ouweland, Ans Mw; Marme, Federick; Schneeweiss, Andreas; Yang, Rongxi; Burwinkel, Barbara; Figueroa, Jonine; Chanock, Stephen J; Lissowska, Jolanta; Sawyer, Elinor J; Tomlinson, Ian; Kerin, Michael J; Miller, Nicola; Brenner, Hermann; Butterbach, Katja; Holleczek, Bernd; Kataja, Vesa; Kosma, Veli-Matti; Hartikainen, Jaana M; Li, Jingmei; Brand, Judith S; Humphreys, Keith; Devilee, Peter; Tollenaar, Robert Aem; Seynaeve, Caroline; Radice, Paolo; Peterlongo, Paolo; Manoukian, Siranoush; Ficarazzi, Filomena; Beckmann, Matthias W; Hein, Alexander; Ekici, Arif B; Balleine, Rosemary; Phillips, Kelly-Anne; Benitez, Javier; Zamora, M Pilar; Perez, Jose Ignacio Arias; Menéndez, Primitiva; Jakubowska, Anna; Lubinski, Jan; Gronwald, Jacek; Durda, Katarzyna; Hamann, Ute; Kabisch, Maria; Ulmer, Hans Ulrich; Rüdiger, Thomas; Margolin, Sara; Kristensen, Vessela; Nord, Siljie; Evans, D Gareth; Abraham, Jean; Earl, Helena; Poole, Christopher J; Hiller, Louise; Dunn, Janet A; Bowden, Sarah; Yang, Rose; Campa, Daniele; Diver, W Ryan; Gapstur, Susan M; Gaudet, Mia M; Hankinson, Susan; Hoover, Robert N; Hüsing, Anika; Kaaks, Rudolf; Machiela, Mitchell J; Willett, Walter; Barrdahl, Myrto; Canzian, Federico; Chin, Suet-Feung; Caldas, Carlos; Hunter, David J; Lindstrom, Sara; Garcia-Closas, Montserrat; Couch, Fergus J; Chenevix-Trench, Georgia; Mannermaa, Arto; Andrulis, Irene L; Hall, Per; Chang-Claude, Jenny; Easton, Douglas F; Bojesen, Stig E; Cox, Angela; Fasching, Peter A; Pharoah, Paul Dp; Schmidt, Marjanka K
2015-04-22
Previous studies have identified common germline variants nominally associated with breast cancer survival. These associations have not been widely replicated in further studies. The purpose of this study was to evaluate the association of previously reported SNPs with breast cancer-specific survival using data from a pooled analysis of eight breast cancer survival genome-wide association studies (GWAS) from the Breast Cancer Association Consortium. A literature review was conducted of all previously published associations between common germline variants and three survival outcomes: breast cancer-specific survival, overall survival and disease-free survival. All associations that reached the nominal significance level of P value <0.05 were included. Single nucleotide polymorphisms that had been previously reported as nominally associated with at least one survival outcome were evaluated in the pooled analysis of over 37,000 breast cancer cases for association with breast cancer-specific survival. Previous associations were evaluated using a one-sided test based on the reported direction of effect. Fifty-six variants from 45 previous publications were evaluated in the meta-analysis. Fifty-four of these were evaluated in the full set of 37,954 breast cancer cases with 2,900 events and the two additional variants were evaluated in a reduced sample size of 30,000 samples in order to ensure independence from the previously published studies. Five variants reached nominal significance (P <0.05) in the pooled GWAS data compared to 2.8 expected under the null hypothesis. Seven additional variants were associated (P <0.05) with ER-positive disease. Although no variants reached genome-wide significance (P <5 x 10(-8)), these results suggest that there is some evidence of association between candidate common germline variants and breast cancer prognosis. Larger studies from multinational collaborations are necessary to increase the power to detect associations, between common variants and prognosis, at more stringent significance levels.
Immunity-Based Aircraft Fault Detection System
NASA Technical Reports Server (NTRS)
Dasgupta, D.; KrishnaKumar, K.; Wong, D.; Berry, M.
2004-01-01
In the study reported in this paper, we have developed and applied an Artificial Immune System (AIS) algorithm for aircraft fault detection, as an extension to a previous work on intelligent flight control (IFC). Though the prior studies had established the benefits of IFC, one area of weakness that needed to be strengthened was the control dead band induced by commanding a failed surface. Since the IFC approach uses fault accommodation with no detection, the dead band, although it reduces over time due to learning, is present and causes degradation in handling qualities. If the failure can be identified, this dead band can be further A ed to ensure rapid fault accommodation and better handling qualities. The paper describes the application of an immunity-based approach that can detect a broad spectrum of known and unforeseen failures. The approach incorporates the knowledge of the normal operational behavior of the aircraft from sensory data, and probabilistically generates a set of pattern detectors that can detect any abnormalities (including faults) in the behavior pattern indicating unsafe in-flight operation. We developed a tool called MILD (Multi-level Immune Learning Detection) based on a real-valued negative selection algorithm that can generate a small number of specialized detectors (as signatures of known failure conditions) and a larger set of generalized detectors for unknown (or possible) fault conditions. Once the fault is detected and identified, an adaptive control system would use this detection information to stabilize the aircraft by utilizing available resources (control surfaces). We experimented with data sets collected under normal and various simulated failure conditions using a piloted motion-base simulation facility. The reported results are from a collection of test cases that reflect the performance of the proposed immunity-based fault detection algorithm.
Nguyen, Huu-Nghi; Tanaka, Mitsuru; Komabayashi, Genki; Matsui, Toshiro
2016-10-01
Matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) is widely used for the detection and analysis of ionizable compounds. However, the method has less potential for the analysis of neutral compounds, such as polyphenols, owing to their lack of favorable proton-attachment or -removal groups. In this study, we reported for the first time that nifedipine (2,6-dimethyl-3,5-dicarbomethoxy-4-(2-nitrophenyl)-1,4-dihydropyridine), which is a strong photobase generator commonly used in polymerization, can abstract protons from neutral compounds in negative mode-MALDI experiments. When nifedipine (5 mg/ml) was used as a matrix reagent, the limit of detection (LOD) for epigallocatechin-3-O-gallate (EGCG) was determined to be 100 fmol/spot, which constitutes >50-fold improvement compared to the LOD obtained when trans-3-indoleacrylic acid, a matrix reagent previously reported for polyphenol detection, was used. Of the dihydropyridines investigated, only nifedipine facilitated the detection of EGCG, suggesting that the nitrosophenyl pyridine derivative of nifedipine formed by photoreduction under laser irradiation at 355 nm plays a crucial role in detecting polyphenols in negative mode. Reduced MS detection of 5-O-methylnaringenin indicated that nifedipine may preferably remove a proton from the 5-position OH group in the A ring of the flavonoid skeleton. The significant MS detection by nifedipine was extensively observed for polyphenols including flavones, flavonones, chalcones, stilbenoids and phenolic acids. In conclusion, nifedipine can act as a novel matrix for improving polyphenol detection by MALDI-MS in negative mode. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Detecting molecules and cells labeled with magnetic particles using an atomic magnetometer
NASA Astrophysics Data System (ADS)
Yu, Dindi; Ruangchaithaweesuk, Songtham; Yao, Li; Xu, Shoujun
2012-09-01
The detection of magnetically labeled molecules and cells involves three essential parameters: sensitivity, spatial resolution, and molecular specificity. We report on the use of atomic magnetometry and its derivative techniques to achieve high performance in terms of all these parameters. With a sensitivity of 80 fT/√Hz for dc magnetic fields, we show that 7,000 streptavidin-conjugated magnetic microparticles magnetized by a permanent magnet produce a magnetic field of 650 pT; this result predicts that a single such particle can be detected during one second of signal averaging. Spatial information is obtained using a scanning magnetic imaging scheme. The spatial resolution is 20 μm with a detection distance of more than 1 cm; this distance is much longer than that in previous reports. The molecular specificity is achieved using force-induced remnant magnetization spectroscopy, which currently uses an atomic magnetometer for detection. As an example, we perform measurement of magnetically labeled human CD4+ T cells, whose count in the blood is the diagnostic criterion for human immunodeficiency virus infection. Magnetic particles that are specifically bound to the cells are resolved from nonspecifically bound particles and quantitatively correlate with the number of cells. The magnetic particles have an overall size of 2.8 μm, with a magnetic core in nanometer regime. The combination of our techniques is predicted to be useful in molecular and cellular imaging.
Joung, Ha Kyung; Han, Sang Ha; Park, Su-Jung; Jheong, Weon-Hwa; Ahn, Tae Seok; Lee, Joong-Bok; Jeong, Yong-Seok; Jang, Kyung Lib; Lee, Gyu-Cheol; Rhee, Ok-Jae; Park, Jeong-Woong; Paik, Soon Young
2013-01-01
Widespread outbreaks of foot-and-mouth disease and avian influenza occurred in South Korea during 2010. In response to the culling of many animals to attenuate the spread of disease, South Korea used mass burial sites to dispose of the large number of carcasses; consequently, concerns about groundwater contamination by leachate from these burial sites are increasing. Groundwater is one of the main sources of drinking water, and its cleanliness is directly related to public health. Thus, this study aimed to evaluate the safety of groundwater around the burial sites (total of 600 sites). A total of 1,200 groundwater samples were collected though the country, and microbial analysis was conducted during two time periods: during the spring (n = 600; April to June 2012) and after rainfall (n = 600; August to October, 2012; fall). Fecal coliform and Escherichia coli were detected in 173 (14.4%) and 85 (7.1%) of the 1,200 samples, respectively. Salmonella spp. and Shigella spp. each were detected only once (0.083%). Clostridium perfringens was detected from 7 groundwater samples (0.583%), and E. coli O157:H7 was not detected. With respect to norovirus, only the GII type was detected from six groundwater samples (0.5%), and enterovirus was detected in 15 groundwater samples (1.25%). The frequency of E. coli that we detected was lower than that found in previous studies conducted in South Korea, but we detected higher frequency of fecal coliform than that observed in a previous report. The contamination frequencies of Salmonella spp. and Shigella spp. were very low, but C. perfringens, which could be an indicator of fecal pollution, was detected in seven regions. Overall, the results of the present study indicate a low possibility of contamination from burial sites. However, consistent monitoring is required to prevent microbial contamination of groundwater near the burial sites. PMID:24351737
NASA Astrophysics Data System (ADS)
Li, J.-H.; Du, Y.; Feng, G.-K.; Du, Y.-B.; Zhou, Y.-Q.; Zeng, M.-S.
2017-11-01
Surface-enhanced Raman scattering (SERS) nanotags as an ultrasensitive nanoprobe is becoming popular for the detection of biomarkers. Herein, antibody-conjugated gold nanoparticles (AuNPs) were used to target LMP2A in an LMP2A-infected CNE2 cell line. SERS maps showed that the LMP2A was distributed around the cell, which was consistent with the results of immunofl uorescence staining in the previous report. This location could be due to the specific binding of the bioconjugated nanotags to the receptors on the cell surface. However, the CNE2 cell line without LMP2A-infected showed no detectable signal at 1044 cm-1. The results demonstrated the potential feasibility of AuNPs nanotags as highly sensitive probes conjugated at the subcellular level for detection and localization of cancer markers in nasopharyngeal carcinoma (NPC).
Glorioso, Brad M.; Waddle, J. Hardin
2017-01-01
The southeastern United States is home to a diverse assemblage of snakes, but only one species, the Rough Greensnake (Opheodrys aestivus), is considered specialized for a predominantly arboreal lifestyle. Other species, such as Ratsnakes (genus Pantherophis) and Ribbonsnakes/Gartersnakes (genus Thamnophis), are widely known to climb into vegetation and trees. Some explanations given for snake climbing behavior are foraging, thermoregulation, predator avoidance, and response to flood. Reports of arboreality in snake species typically not associated with life in the trees (such as terrestrial, aquatic, and even fossorial species) usually come from single observations, with no knowledge of prevalence of the behavior. Here, we report on arboreality of snake species detected during 8 years of night surveys in the Atchafalaya Basin of south-central Louisiana and 5+ years of night surveys in Big Thicket National Preserve in southeast Texas. We recorded a total of 1,088 detections of 19 snake species between the two study areas, with 348 detections above ground level (32%). The Rough Greensnake and Western Ribbonsnake (Thamnophis proximus) accounted for nearly 75% of total arboreal detections among the two study areas. However, with one exception, all snake species detected more than once between both study areas had at least one arboreal detection. These observations demonstrate that snakes with widely varying natural histories may be found in the trees at night, and for some species, this behavior may be more common than previously believed.
Abraham, Michael H.
2010-01-01
We have measured concentration detection (i.e., psychometric) functions to determine the odor detectability of homologous aliphatic aldehydes (propanal, butanal, hexanal, octanal, and nonanal) and helional. Subjects (16 ≤ n ≤ 18) used a 3-alternative forced-choice procedure against carbon-filtered air (blanks), under an ascending concentration approach. Generation, delivery, and control of each vapor were achieved via an 8-station vapor delivery device. Gas chromatography served to quantify the concentrations presented. Group and individual functions were modeled by a sigmoid (logistic) equation. Odor detection thresholds (ODTs) were defined as the concentration producing a detectability (P) halfway (P = 0.5) between chance (P = 0.0) and perfect detection (P = 1.0). ODTs decreased with carbon chain length: 2.0, 0.46, 0.33, and 0.17 ppb, respectively, from propanal to octanal, but the threshold increased for nonanal (0.53 ppb), revealing maximum sensitivity for the 8-carbon member. The strong olfactory receptor (OR) ligands octanal and helional (0.14 ppb) showed the lowest thresholds. ODTs fell at the lower end of previously reported values. Interindividual variability (ODT ratios) amounted to a factor ranging from 10 to 50, lower than typically reported, and was highest for octanal and hexanal. The behavioral dose–response functions emerge at concentrations 2–5 orders of magnitude lower than those required for functions tracing the activation of specific human ORs by the same aldehydes in cell/molecular studies, after all functions were expressed as vapor concentrations. PMID:20190010
A novel mechanism for a survival advantage of vigilant individuals in groups.
van der Post, Daniel J; de Weerd, Harmen; Verbrugge, Rineke; Hemelrijk, Charlotte K
2013-11-01
In many animal species, vigilance is crucial for avoiding predation. In groups, however, nonvigilant individuals could benefit from the vigilance of others without any of the associated costs. In an evolutionary sense, such exploitation may be compensated if vigilant individuals have a survival advantage. The novelty in our model is that the probability to detect a predator is "distance dependent." We show that even if nonvigilant individuals benefit fully from information produced by vigilant individuals, vigilant individuals nevertheless enjoy a survival advantage. This happens because detection of predators is more likely when vigilant individuals happen to be targets of predation. We expect this distance-dependent mechanism to be compatible with previously reported mechanisms.
Laboureur, Laurent; Guérineau, Vincent; Auxilien, Sylvie; Yoshizawa, Satoko; Touboul, David
2018-02-16
A method based on supercritical fluid chromatography coupled to high resolution mass spectrometry for the profiling of canonical and modified nucleosides was optimized, and compared to classical reverse-phase liquid chromatography in terms of separation, number of detected modified nucleosides and sensitivity. Limits of detection and quantification were measured using statistical method and quantifications of twelve nucleosides of a tRNA digest from E. coli are in good agreement with previously reported data. Results highlight the complementarity of both separation techniques to cover the largest view of nucleoside modifications for forthcoming epigenetic studies. Copyright © 2017 Elsevier B.V. All rights reserved.
The design and integration of retinal CAD-SR to diabetes patient ePR system
NASA Astrophysics Data System (ADS)
Wu, Huiqun; Wei, Yufang; Liu, Brent J.; Shang, Yujuan; Shi, Lili; Jiang, Kui; Dong, Jiancheng
2017-03-01
Diabetic retinopathy (DR) is one of the serious complications of diabetes that could lead to blindness. Digital fundus camera is often used to detect retinal changes but the diagnosis relies too much on ophthalmologist's experience. Based on our previously developed algorithms for quantifying retinal vessels and lesions, we developed a computer aided detection-structured report (CAD-SR) template and implemented it into picture archiving and communication system (PACS). Furthermore, we mapped our CAD-SR into HL7 CDA to integrate CAD findings into diabetes patient electronic patient record (ePR) system. Such integration could provide more quantitative features from fundus image into ePR system, which is valuable for further data mining researches.
Kokubun, Hideya; Ouki, Makiko; Matoba, Motohiro; Kubo, Hiroaki; Hoka, Sumio; Yago, Kazuo
2005-03-01
We developed an HPLC procedure using electrochemical detection for the quantitation of oxycodone and hydrocotarnine in cancer patients serum. An eluent of methanol:acetonitrile:5 mM pH 8 phosphate buffer (2:1:7) was used for the mobile phase. The calibration curve was linear in the range from 10 ng/mL to 100 ng/mL. The recovery of oxycodone and hydrocotarnine was 97.2% and 90.5%, respectively. The relative standard deviations within-runs and between-runs for the assay of oxycodone or hydrocotarnine were less than 4.8%. The method developed here was better than the method reported previously.
Pure detection of the acoustic spin pumping in Pt/YIG/PZT structures
NASA Astrophysics Data System (ADS)
Uchida, Ken-ichi; Qiu, Zhiyong; Kikkawa, Takashi; Saitoh, Eiji
2014-11-01
The acoustic spin pumping (ASP) stands for the generation of a spin voltage from sound waves in a ferromagnet/paramagnet junction. In this letter, we propose and demonstrate a method for pure detection of the ASP, which enables the separation of sound-wave-driven spin currents from the spin Seebeck effect due to the heating of a sample caused by a sound-wave injection. Our demonstration using a Pt/YIG/PZT sample shows that the ASP signal in this structure measured by a conventional method is considerably offset by the heating signal and that the pure ASP signal is one order of magnitude greater than that reported in the previous study.
Observation of two-photon interference with continuous variables by homodyne detection
NASA Astrophysics Data System (ADS)
Wu, Daohua; Kawamoto, Kota; Guo, Xiaomin; Kasai, Katsuyuki; Watanabe, Masayoshi; Zhang, Yun
2017-10-01
We experimentally observed a two-photon interference between a squeezed vacuum state from an optical parametric amplifier and a weak coherent state on a beam splitter with continuous variables. The photon statistics properties of the mixed field were investigated by calculating the correlations among four permutations of measured quadratures components, which were obtained by two homodyne detection systems. This also means that the two-photon interference occurred at analysis frequency differing from the previous two-photon interference reports. The nonclassical effect of photon anti-bunching occurred when an amplitude squeezed vacuum state acted as one of interference sources. On the other hand, the photon bunching effect appeared when a phase squeezed vacuum state was employed.
2012-07-18
For AlGaN, it is found that Al2O3, Ga2O3 and N-O states were detected on native oxide and HF-treated surfaces. During the course of the ALD process...the N-O bonds are seen to decrease to a level near XPS detection limits, as well as a small decrease in the Ga2O3 concentration, consistent with a...and the other at 1118.2 eV, indicative of a Ga 3+ oxidation state, likely due to Ga2O3 , consistent with previous reports.22,23 There is no evidence
Unexpected Relationships and Inbreeding in HapMap Phase III Populations
Stevens, Eric L.; Baugher, Joseph D.; Shirley, Matthew D.; Frelin, Laurence P.; Pevsner, Jonathan
2012-01-01
Correct annotation of the genetic relationships between samples is essential for population genomic studies, which could be biased by errors or omissions. To this end, we used identity-by-state (IBS) and identity-by-descent (IBD) methods to assess genetic relatedness of individuals within HapMap phase III data. We analyzed data from 1,397 individuals across 11 ethnic populations. Our results support previous studies (Pemberton et al., 2010; Kyriazopoulou-Panagiotopoulou et al., 2011) assessing unknown relatedness present within this population. Additionally, we present evidence for 1,657 novel pairwise relationships across 9 populations. Surprisingly, significant Cotterman's coefficients of relatedness K1 (IBD1) values were detected between pairs of known parents. Furthermore, significant K2 (IBD2) values were detected in 32 previously annotated parent-child relationships. Consistent with a hypothesis of inbreeding, regions of homozygosity (ROH) were identified in the offspring of related parents, of which a subset overlapped those reported in previous studies (Gibson et al. 2010; Johnson et al. 2011). In total, we inferred 28 inbred individuals with ROH that overlapped areas of relatedness between the parents and/or IBD2 sharing at a different genomic locus between a child and a parent. Finally, 8 previously annotated parent-child relationships had unexpected K0 (IBD0) values (resulting from a chromosomal abnormality or genotype error), and 10 previously annotated second-degree relationships along with 38 other novel pairwise relationships had unexpected IBD2 (indicating two separate paths of recent ancestry). These newly described types of relatedness may impact the outcome of previous studies and should inform the design of future studies relying on the HapMap Phase III resource. PMID:23185369
Distinct frontal and amygdala correlates of change detection for facial identity and expression
Achaibou, Amal; Loth, Eva
2016-01-01
Recruitment of ‘top-down’ frontal attentional mechanisms is held to support detection of changes in task-relevant stimuli. Fluctuations in intrinsic frontal activity have been shown to impact task performance more generally. Meanwhile, the amygdala has been implicated in ‘bottom-up’ attentional capture by threat. Here, 22 adult human participants took part in a functional magnetic resonance change detection study aimed at investigating the correlates of successful (vs failed) detection of changes in facial identity vs expression. For identity changes, we expected prefrontal recruitment to differentiate ‘hit’ from ‘miss’ trials, in line with previous reports. Meanwhile, we postulated that a different mechanism would support detection of emotionally salient changes. Specifically, elevated amygdala activation was predicted to be associated with successful detection of threat-related changes in expression, over-riding the influence of fluctuations in top-down attention. Our findings revealed that fusiform activity tracked change detection across conditions. Ventrolateral prefrontal cortical activity was uniquely linked to detection of changes in identity not expression, and amygdala activity to detection of changes from neutral to fearful expressions. These results are consistent with distinct mechanisms supporting detection of changes in face identity vs expression, the former potentially reflecting top-down attention, the latter bottom-up attentional capture by stimulus emotional salience. PMID:26245835
Internal carotid artery rupture caused by carotid shunt insertion.
Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco
2015-01-01
Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Xu, Wentao; Tian, Jingjing; Shao, Xiangli; Zhu, Longjiao; Huang, Kunlun; Luo, Yunbo
2017-03-15
For previously reported aptasensor, the sensitivity and selectivity of aptamers to targets were often suppressed due to the reporter label of single-stranded molecular beacon or hindrance of the duplex DNA strand displacement. To solve the affinity declining of aptamers showed in traditional way and realize on-site rapid detection of Lipopolysaccharides (LPS), we developed an ingenious structure-switching aptasensor based on the bulb-like triplex turn-on switch (BTTS) as the effective molecular recognition and signal transduction element and streptavidin-horseradish peroxidase modified hybridization chain reaction (HCR-HRP) nanocomposites as the signal amplifier and signal report element. In the presence of LPS, the bulb-like LPS-aptamer (BLA) and LPS formed the LPS/aptamer complex, while the BTTS disassembled and liberated the dissociative bridge probes (BP) to achieve molecular recognition and signal transduction. Immobilized BP, captured by immobilized capture probes (CP), triggered hybridization chain reactions (HCR) to amplify the switching signal, and the HCR products were then modified with streptavidin-horseradish peroxidase (SA-HRP) to form HCR-HRP nanostructures to output colorimetric signals. In less than four hours, the proposed biosensor showed a detection limit of 50pg/mL of LPS quantitatively with the portable spectrophotometer and the observation limit of 20ng/mL semi-quantitatively with the naked eye, opening up new opportunities for LPS detection in future clinical diagnosis, food security and environment monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.
Corrections of clinical chemistry test results in a laboratory information system.
Wang, Sihe; Ho, Virginia
2004-08-01
The recently released reports by the Institute of Medicine, To Err Is Human and Patient Safety, have received national attention because of their focus on the problem of medical errors. Although a small number of studies have reported on errors in general clinical laboratories, there are, to our knowledge, no reported studies that focus on errors in pediatric clinical laboratory testing. To characterize the errors that have caused corrections to have to be made in pediatric clinical chemistry results in the laboratory information system, Misys. To provide initial data on the errors detected in pediatric clinical chemistry laboratories in order to improve patient safety in pediatric health care. All clinical chemistry staff members were informed of the study and were requested to report in writing when a correction was made in the laboratory information system, Misys. Errors were detected either by the clinicians (the results did not fit the patients' clinical conditions) or by the laboratory technologists (the results were double-checked, and the worksheets were carefully examined twice a day). No incident that was discovered before or during the final validation was included. On each Monday of the study, we generated a report from Misys that listed all of the corrections made during the previous week. We then categorized the corrections according to the types and stages of the incidents that led to the corrections. A total of 187 incidents were detected during the 10-month study, representing a 0.26% error detection rate per requisition. The distribution of the detected incidents included 31 (17%) preanalytic incidents, 46 (25%) analytic incidents, and 110 (59%) postanalytic incidents. The errors related to noninterfaced tests accounted for 50% of the total incidents and for 37% of the affected tests and orderable panels, while the noninterfaced tests and panels accounted for 17% of the total test volume in our laboratory. This pilot study provided the rate and categories of errors detected in a pediatric clinical chemistry laboratory based on the corrections of results in the laboratory information system. A direct interface of the instruments to the laboratory information system showed that it had favorable effects on reducing laboratory errors.
French, Daniel G; Allen, Philippe D; Ellsmere, James C
2013-11-01
Transabdominal ultrasonography (TAUS) is the most commonly used modality to diagnose gallbladder (GB) disease. GB polyps are reported in 1-5.6 % of TAUS studies. Histopathologic studies suggest that there is a relationship between GB polyps and GB cancer. Previous literature suggests GB polyps reported on TAUS do not correlate well with histological findings. There have been recent advances in TAUS technology. We hypothesize the recent advances in TAUS technology have improved the accuracy of TAUS for diagnosing GB polyps. Radiology and pathology databases at our tertiary care center were retrospectively searched between January 1, 2000, and December 31, 2010. Ultrasound reports that suggested a GB polyp was present on TAUS were correlated to histopathology in cases where a cholecystectomy was performed. The pathology reports where a GB polyp was found were correlated with preoperative TAUS reports. There were 102,740 TAUS reports referring to the GB, of which 6,612 (6.4 %) contained search terms suggesting a GB polyp was present. There were 13,278 cholecystectomy pathology reports, of which 159 (1.2 %) included a diagnosis of GB polyp. TAUS detected only 50 % of the polyps identified on histopathology. The sensitivity and specificity of TAUS for diagnosing GB polyps were 50.0 and 98.3 %, respectively. The positive and negative predictive values were 10.5 and 99.8 %. Despite improvement in TAUS technology, the accuracy for GB polyps remains poor. This needs to be considered when managing patients with TAUS-detected GB polyps. We recommend that the decision to operate on TAUS-detected GB polyps be largely based on symptoms, and following GB polyps with TAUS should be discouraged.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, Howie; Lawrence, Shayla; Rebellato, Betty
2004-01-01
The purpose of this addendum is, first, to provide and discuss disease agent survey results that were not available for inclusion in the Disease Risk Assessment portion of the YEAR 3 report at the time of its writing, and second, to make recommendations stemming from these results. The first set of results deals with live box exposure tests conducted using juvenile sentinel rainbow trout in the spring of 2002 to detect Myxosoma cerebralis and Ceratomyxa shasta. The second set of results deals with similar exposure tests conducted in the spring of 2003. The latter tests were initially intended to occurmore » in the fall of 2002 but had to be re-scheduled to the spring of 2003 because suitably aged sentinel rainbow trout for the exposures were not available in the fall of 2002. The methods used for the live box exposure tests were essentially the same as those described in the YEAR 3 report. Fish were again exposed at the same four sites above McIntyre Dam and at the same four sites below the dam. As mentioned in the YEAR 3 report, the spring 2002 exposure lasted for 21 days (May 6 to 27). The spring 2003 exposure also lasted for 21 days (April 22 to May 13). The number of fish in the spring 2003 tests was, however, reduced to approximately half the number used in previous tests in order to reduce the chances of dissolved oxygen problems, suspected to have occurred in earlier tests in some of the live boxes. As before, fish that survived the live box exposures were transferred to Skaha Hatchery where they were held for sufficient time to permit any infections with M. cerebralis and C. shasta to develop and to permit for spore development in these pathogens. Assays for the pathogens were carried out as previously described. Detection of M. cerebralis was based on detecting its spores following the trypsin/pepsin digestion method. Detection of C. shasta was based on a polymerase chain reaction (PCR) test, but smears of fresh intestinal tissues (one fish per smear) were also prepared so that positive PCR findings could be confirmed by the microscopic observation of C. shasta spores. Except as just mentioned, appropriate tissues from the fish were in most cases pooled (maximum of five fish per pool) for the assays.« less
Satisfaction of Search in Chest Radiography 2015.
Berbaum, Kevin S; Krupinski, Elizabeth A; Schartz, Kevin M; Caldwell, Robert T; Madsen, Mark T; Hur, Seung; Laroia, Archana T; Thompson, Brad H; Mullan, Brian F; Franken, Edmund A
2015-11-01
Two decades have passed since the publication of laboratory studies of satisfaction of search (SOS) in chest radiography. Those studies were performed using film. The current investigation tests for SOS effects in computed radiography of the chest. Sixty-four chest computed radiographs half demonstrating various "test" abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Results of previous studies were reanalyzed using similar modern techniques. In the present study, adding nodules did not influence detection accuracy for the other abnormalities (P = .93), but did induce a reluctance to report them (P < .001). Adding nodules did not affect inspection time (P = .58) so the reluctance to report was not associated with reduced search. Reanalysis revealed a similar decision threshold shift that had not been recognized in the early studies of SOS in chest radiography (P < .01) in addition to reduced detection accuracy (P < .01). The nature of SOS in chest radiography has changed, but it is not clear why. SOS may be changing as a function of changes in radiology education and practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Rusconi, Elena; Ferri, Francesca; Viding, Essi; Mitchener-Nissen, Timothy
2015-01-01
X-ray imaging is a cost-effective technique at security checkpoints that typically require the presence of human operators. We have previously shown that self-reported attention to detail can predict threat detection performance with small-vehicle x-ray images (Rusconi et al., 2012). Here, we provide evidence for the generality of such a link by having a large sample of naïve participants screen more typical dual-energy x-ray images of hand luggage. The results show that the Attention to Detail score from the autism-spectrum quotient (AQ) questionnaire (Baron-Cohen et al., 2001) is a linear predictor of threat detection accuracy. We then develop and fine-tune a novel self-report scale for security screening: the XRIndex, which improves on the Attention to Detail scale for predictive power and opacity to interpretation. The XRIndex is not redundant with any of the Big Five personality traits. We validate the XRIndex against security x-ray images with an independent sample of untrained participants and suggest that the XRIndex may be a useful aid for the identification of suitable candidates for professional security training with a focus on x-ray threat detection. Further studies are needed to determine whether this can also apply to trained professionals. PMID:26321935
Rosin, P; Niskanen, T; Palm, D; Struelens, M; Takkinen, J
2013-06-20
A hybrid strain of enteroaggregative and Shiga toxin 2-producing Escherichia coli (EAEC-STEC) serotype O104:H4 strain caused a large outbreak of haemolytic uraemic syndrome and bloody diarrhoea in 2011 in Europe. Two surveys were performed in the European Union (EU) and European Economic Area (EEA) countries to assess their laboratory capabilities to detect and characterise this previously uncommon STEC strain. Prior to the outbreak, 11 of the 32 countries in this survey had capacity at national reference laboratory (NRL) level for epidemic case confirmation according to the EU definition. During the outbreak, at primary diagnostic level, nine countries reported that clinical microbiology laboratories routinely used Shiga toxin detection assays suitable for diagnosis of infections with EAEC-STEC O104:H4, while 14 countries had NRL capacity to confirm epidemic cases. Six months after the outbreak, 22 countries reported NRL capacity to confirm such cases following initiatives taken by NRLs and the European Centre for Disease Prevention and Control (ECDC) Food- and Waterborne Disease and Zoonoses laboratory network. These data highlight the challenge of detection and confirmation of epidemic infections caused by atypical STEC strains and the benefits of coordinated EU laboratory networks to strengthen capabilities in response to a major outbreak.
NASA Astrophysics Data System (ADS)
Kenton, Arthur C.; Geci, Duane M.; Ray, Kristofer J.; Thomas, Clayton M.; Salisbury, John W.; Mars, John C.; Crowley, James K.; Witherspoon, Ned H.; Holloway, John H., Jr.
2004-09-01
The objective of the Office of Naval Research (ONR) Rapid Overt Reconnaissance (ROR) program and the Airborne Littoral Reconnaissance Technologies (ALRT) project's LAMBS effort is to determine if electro-optical spectral discriminants exist that are useful for the detection of land mines in littoral regions. Statistically significant buried mine overburden and background signature data were collected over a wide spectral range (0.35 to 14 μm) to identify robust spectral features that might serve as discriminants for new airborne sensor concepts. LAMBS has expanded previously collected databases to littoral areas - primarily dry and wet sandy soils - where tidal, surf, and wind conditions can severely modify spectral signatures. At AeroSense 2003, we reported completion of three buried mine collections at an inland bay, Atlantic and Gulf of Mexico beach sites. We now report LAMBS spectral database analyses results using metrics which characterize the detection performance of general types of spectral detection algorithms. These metrics include mean contrast, spectral signal-to-clutter, covariance, information content, and spectral matched filter analyses. Detection performance of the buried land mines was analyzed with regard to burial age, background type, and environmental conditions. These analyses considered features observed due to particle size differences, surface roughness, surface moisture, and compositional differences.
Oya, Maiko; Takahashi, Toshiaki; Tanabe, Hidenori; Oe, Makoto; Murayama, Ryoko; Yabunaka, Koichi; Matsui, Yuko; Sanada, Hiromi
Infiltration is a frequent complication of infusion therapy. We previously demonstrated the usefulness of infrared thermography as an objective method of detecting infiltration in healthy people. However, whether thermography can detect infiltration in clinical settings remains unknown. Therefore, we report two cases where thermography was useful in detecting infiltration at puncture sites. In both cases, tissue changes were verified ultrasonographically. The patients were a 56-year-old male with cholangitis and a 76-year-old female with hepatoma. In both cases, infiltration symptoms such as swelling and erythema occurred one day after the insertion of a peripheral intravenous catheter. Thermographic images from both patients revealed low-temperature areas spreading from the puncture sites; however, these changes were not observed in other patients. The temperature difference between the low-temperature areas and their surrounding skin surface exceeded 1.0°C. Concurrently, ultrasound images revealed that tissues surrounding the vein had a cobblestone appearance, indicating edema. In both patients, subcutaneous tissue changes suggested infiltration and both had low-temperature areas spreading from the puncture sites. Thus, subcutaneous edema may indicate infusion leakage, resulting in a decrease in the temperature of the associated skin surface. These cases suggest that infrared thermography is an effective method of objectively and noninvasively detecting infiltration.
Kenton, A.C.; Geci, D.M.; Ray, K.J.; Thomas, C.M.; Salisbury, J.W.; Mars, J.C.; Crowley, J.K.; Witherspoon, N.H.; Holloway, J.H.; Harmon R.S.Broach J.T.Holloway, Jr. J.H.
2004-01-01
The objective of the Office of Naval Research (ONR) Rapid Overt Reconnaissance (ROR) program and the Airborne Littoral Reconnaissance Technologies (ALRT) project's LAMBS effort is to determine if electro-optical spectral discriminants exist that are useful for the detection of land mines in littoral regions. Statistically significant buried mine overburden and background signature data were collected over a wide spectral range (0.35 to 14 ??m) to identify robust spectral features that might serve as discriminants for new airborne sensor concepts. LAMBS has expanded previously collected databases to littoral areas - primarily dry and wet sandy soils - where tidal, surf, and wind conditions can severely modify spectral signatures. At AeroSense 2003, we reported completion of three buried mine collections at an inland bay, Atlantic and Gulf of Mexico beach sites.1 We now report LAMBS spectral database analyses results using metrics which characterize the detection performance of general types of spectral detection algorithms. These metrics include mean contrast, spectral signal-to-clutter, covariance, information content, and spectral matched filter analyses. Detection performance of the buried land mines was analyzed with regard to burial age, background type, and environmental conditions. These analyses considered features observed due to particle size differences, surface roughness, surface moisture, and compositional differences.
FERMI Observations of TeV-Selected Active Galactic Nuclei
Abdo, A. A.; Ackermann, M.; Ajello, M.; ...
2009-12-04
Here, we report on observations of TeV-selected active galactic nuclei (AGNs) made during the first 5.5 months of observations with the Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope (Fermi). In total, 96 AGNs were selected for study, each being either (1) a source detected at TeV energies (28 sources) or (2) an object that has been studied with TeV instruments and for which an upper limit has been reported (68 objects). The Fermi observations show clear detections of 38 of these TeV-selected objects, of which 21 are joint GeV-TeV sources, and 29 were not in the thirdmore » EGRET catalog. For each of the 38 Fermi-detected sources, spectra and light curves are presented. Most can be described with a power law of spectral index harder than 2.0, with a spectral break generally required to accommodate the TeV measurements. Based on an extrapolation of the Fermi spectrum, we identify sources, not previously detected at TeV energies, which are promising targets for TeV instruments. Finally, evidence for systematic evolution of the γ-ray spectrum with redshift is presented and discussed in the context of interaction with the extragalactic background light.« less
Kolpin, D.W.; Goolsby, D.A.; Thurman, E.M.
1995-01-01
In 1992, the U.S. Geological Survey (USGS) determined the distribution of pesticides in near-surface aquifers of the midwestern USA to be much more widespread than originally determined during a 1991 USGS study. The frequency of pesticide detection increased from 28.4% during the 1991 study to 59.0% during the 1992 study. This increase in pesticide detection was primarily the result of a more sensitive analytical method that used reporting limits as much as 20 times lower than previously available and a threefold increase in the number of pesticide metabolites analyzed. No pesticide concentrations exceeded the U.S. Environmental Protection Agency's (USEPAs) maximum contaminant levels or health advisory levels for drinking water. However, five of the six most frequently detected compounds during 1992 were pesticide metabolites that currently do not have drinking water standards determined. The frequent presence of pesticide metabolites for this study documents the importance of obtaining information on these compounds to understand the fate and transport of pesticides in the hydrologic system. It appears that the 56 parent compounds analyzed follow similar pathways through the hydrologic system as atrazine. When atrazine was detected by routine or sensitive analytical methods, there was an increased likelihood of detecting additional parent compounds. As expected, the frequency of pesticide detection was highly dependent on the analytical reporting limit. The number of atrazine detections more than doubled as the reporting limit decreased from 0.10 to 0.01 µg/L. The 1992 data provided no indication that the frequency of pesticide detection would level off as improved analytical methods provide concentrations below 0.003 µg/L. A relation was determined between groundwater age and the frequency of pesticide detection, with 15.8% of the samples composed of pre-1953 water and 70.3% of the samples of post-1953 water having a detection of at least one pesticide or metabolite. Pre-1953 water is less likely to contain pesticides because it tends to predate the use of pesticides to increase crop production in the Midwest. Pre-1953 water was more likely to occur in the near-surface bedrock aquifers (50.0%) than in the near-surface unconsolidated aquifers (9.1%) sampled.
Jain, Paras; Hartman, Travis E; Eisenberg, Nell; O'Donnell, Max R; Kriakov, Jordan; Govender, Karnishree; Makume, Mantha; Thaler, David S; Hatfull, Graham F; Sturm, A Willem; Larsen, Michelle H; Moodley, Preshnie; Jacobs, William R
2012-04-01
The difficulty of diagnosing active tuberculosis (TB) and lack of rapid drug susceptibility testing (DST) at the point of care remain critical obstacles to TB control. This report describes a high-intensity mycobacterium-specific-fluorophage (φ(2)GFP10) that for the first time allows direct visualization of Mycobacterium tuberculosis in clinical sputum samples. Engineered features distinguishing φ(2)GFP10 from previous reporter phages include an improved vector backbone with increased cloning capacity and superior expression of fluorescent reporter genes through use of an efficient phage promoter. φ(2)GFP10 produces a 100-fold increase in fluorescence per cell compared to existing reporter phages. DST for isoniazid and oxofloxacin, carried out in cultured samples, was complete within 36 h. Use of φ(2)GFP10 detected M. tuberculosis in clinical sputum samples collected from TB patients. DST for rifampin and kanamycin from sputum samples yielded results after 12 h of incubation with φ(2)GFP10. Fluorophage φ(2)GFP10 has potential for clinical development as a rapid, sensitive, and inexpensive point-of-care diagnostic tool for M. tuberculosis infection and for rapid DST.
Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide
2016-01-01
An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the usefulness of OXR in the diagnosis of the occult pneumothorax and to compare OXR with ultrasonography. All consecutive blunt chest trauma patients with clinically suspected pneumothorax on arrival at the emergency department were prospectively included at our tertiary-care center. The patients underwent OXR and ultrasonography, and underwent computed tomography scans as the gold standard. Occult pneumothorax size on computed tomography was classified as minuscule, anterior, or anterolateral. One hundred and fifty-nine patients were enrolled. Of the 70 occult pneumothoraces found in the 318 thoraces, 19 were minuscule, 32 were anterior, and 19 were anterolateral. The sensitivity and specificity of OXR for detecting occult pneumothorax was 61.4 % and 99.2 %, respectively. The sensitivity and specificity of lung ultrasonography was 62.9 % and 98.8 %, respectively. Among 27 occult pneumothoraces that could not be detected by OXR, 16 were minuscule and 21 could be conservatively managed without thoracostomy. OXR appears to be as good method as lung ultrasonography in the detection of large occult pneumothorax. In trauma patients who are difficult to transfer to computed tomography scan, OXR may be effective at detecting occult pneumothorax with a risk of progression.
Media Literacy Education for Elementary School Substance Use Prevention: Study of Media Detective
Kupersmidt, Janis B.; Scull, Tracy M.; Austin, Erica Weintraub
2017-01-01
OBJECTIVES Media Detective is a 10-lesson elementary school substance use prevention program developed on the basis of the message interpretation processing model designed to increase children’s critical thinking skills about media messages and reduce intent to use tobacco and alcohol products. The purpose of this study was to conduct a short-term, randomized, controlled trial to evaluate the effectiveness of Media Detective for achieving these goals. METHODS Elementary schools were randomly assigned to conditions to either receive the Media Detective program (n = 344) or serve in a waiting list control group (n = 335). RESULTS Boys in the Media Detective group reported significantly less interest in alcohol-branded merchandise than boys in the control group. Also, students who were in the Media Detective group and had used alcohol or tobacco in the past reported significantly less intention to use and more self-efficacy to refuse substances than students who were in the control group and had previously used alcohol or tobacco. CONCLUSIONS This evaluation provides evidence that Media Detective can be effective for substance use prevention in elementary school–aged children. Notably, media-related cognitions about alcohol and tobacco products are malleable and relevant to the development and maintenance of substance use behaviors during late childhood. The findings from this study suggest that media literacy– based interventions may serve as both a universal and a targeted prevention program that has potential for assisting elementary school children in making healthier, more informed decisions about use of alcohol and tobacco products. PMID:20732940
Outburst of the recurrent nova V745 Sco
NASA Astrophysics Data System (ADS)
Waagen, Elizabeth O.
2014-02-01
The outburst of the recurrent nova V745 Sco (Nova Sco 1937) by Rod Stubbings (Tetoora Road, VIC, Australia) at visual magnitude 9.0 on 2014 February 6.694 UT is reported. This recurrent nova is fading quickly. Follow-up observations of all types (visual, CCD, DSLR) are strongly encouraged, as is spectroscopy; fast time-series of this nova may be useful to detect possible flaring activity as was observed during the outburst of U Scorpii in 2010. Coincident time-series by multiple observers would be most useful for such a study, with a V-filter being preferred. Observations reported to the AAVSO International Database show V745 Sco at visual mag. 10.2 on 2014 Feb. 07.85833 UT (A. Pearce, Nedlands, W. Australia). Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. Previous outbursts occurred in 1937 and 1989. The 1937 outburst was detected in 1958 (in decline at magnitude 11.0 on 1937 May 11.1 UT; outburst had occurred within the previous 19 days) by Lukas Plaut on plates taken by Hendrik van Gent at the Leiden Observatory; the object was announced as Nova Sco 1937 and later assigned the GCVS name V745 Sco. The 1989 outburst was detected on 1989 August 1.55 UT by Mati Morel (MMAT, Thornton, NSW, Australia) at visual magnitude 10.4 and in decline. Dr. Bradley Schaefer (Louisiana State University) reports (2010ApJS..187..275S) in his comprehensive analysis of the 10 known galactic recurrent novae (including V745 Sco) that the median interval between recurrent novae outbursts is 24 years. The interval since the 1989 outburst of V745 Sco is 24.10 years. See the Alert Notice for additional visual and multicolor photometry and for more details.
ATP-activated P2X2 current in mouse spermatozoa
Navarro, Betsy; Miki, Kiyoshi; Clapham, David E.
2011-01-01
Sperm cells acquire hyperactivated motility as they ascend the female reproductive tract, which enables them to overcome barriers and penetrate the cumulus and zona pellucida surrounding the egg. This enhanced motility requires Ca2+ entry via cation channel of sperm (CatSper) Ca2+-selective ion channels in the sperm tail. Ca2+ entry via CatSper is enhanced by the membrane hyperpolarization mediated by Slo3, a K+ channel also present in the sperm tail. To date, no transmitter-mediated currents have been reported in sperm and no currents have been detected in the head or midpiece of mature spermatozoa. We screened a number of neurotransmitters and biomolecules to examine their ability to induce ion channel currents in the whole spermatozoa. Surprisingly, we find that none of the previously reported neurotransmitter receptors detected by antibodies alone are functional in mouse spermatozoa. Instead, we find that mouse spermatozoa have a cation-nonselective current in the midpiece of spermatozoa that is activated by external ATP, consistent with an ATP-mediated increase in intracellular Ca2+ as previously reported. The ATP-dependent current is not detected in mice lacking the P2X2 receptor gene (P2rx2−/−). Furthermore, the slowly desensitizing and strongly outwardly rectifying ATP-gated current has the biophysical and pharmacological properties that mimic heterologously expressed mouse P2X2. We conclude that the ATP-induced current on mouse spermatozoa is mediated by the P2X2 purinergic receptor/channel. Despite the loss of ATP-gated current, P2rx2−/− spermatozoa have normal progressive motility, hyperactivated motility, and acrosome reactions. However, fertility of P2rx2−/− males declines with frequent mating over days, suggesting that P2X2 receptor adds a selection advantage under these conditions. PMID:21831833
Ward, Jamie; Jonas, Clare; Dienes, Zoltan; Seth, Anil
2010-04-07
For people with synaesthesia letters and numbers may evoke experiences of colour. It has been previously demonstrated that these synaesthetes may be better at detecting a triangle made of 2s among a background of 5s if they perceive 5 and 2 as having different synaesthetic colours. However, other studies using this task (or tasks based on the same principle) have failed to replicate the effect or have suggested alternative explanations of the effect. In this study, we repeat the original study on a larger group of synaesthetes (n = 36) and include, for the first time, an assessment of their self-reported colour experiences. We show that synaesthetes do have a general advantage over controls on this task. However, many synaesthetes report no colour experiences at all during the task. Synaesthetes who do report colour typically experience around one third of the graphemes in the display as coloured. This is more consistent with theories of synaesthesia in which spatial attention needs to be deployed to graphemes for conscious colour experiences to emerge than the interpretation based on 'pop-out'.
Horiuchi, Katsumi; Ariga, Tadashi; Fujioka, Hirotaka; Kawashima, Kunihiro; Yamamoto, Yuhei; Igawa, Hiroharu; Sugihara, Tsuneki; Sakiyama, Yukio
2005-05-01
Treacher Collins Syndrome (TCS) (OMIM 154500) is a congenital, craniofacial disorder inherited as an autosomal dominant trait. The responsible gene for TCS, TCOF1, was mapped to 5q32-33.1 and identified in 1996. Since then, TCOF1 mutations in patients with TCS have been reported from Europe, North and South America, however, no TCS cases from an Asian country have been molecularly characterized. Here we report mutational analysis for 11 Japanese patients with TCS for the first time, and have identified TCOF1 mutations in 9 of them. The mutations detected were various, but most likely all the mutations are predicted to result in a truncated gene product, known as treacle. One mutation frequently reported was included in our cases, but no missense mutations were detected. These findings are similar to those for the previous studies for TCS in other races. We have speculated about the molecular mechanisms of the mutations in most cases. Collectively, we have defined some of the characteristic molecular features commonly observed in TCS patients, irrespective of racial difference. 2005 Wiley-Liss, Inc.
The effect of the rate of hydrostatic pressure depressurization on cells in culture.
Tworkoski, Ellen; Glucksberg, Matthew R; Johnson, Mark
2018-01-01
Changes in hydrostatic pressure, at levels as low as 10 mm Hg, have been reported in some studies to alter cell function in vitro; however, other studies have found no detectable changes using similar methodologies. We here investigate the hypothesis that the rate of depressurization, rather than elevated hydrostatic pressure itself, may be responsible for these reported changes. Hydrostatic pressure (100 mm Hg above atmospheric pressure) was applied to bovine aortic endothelial cells (BAECs) and PC12 neuronal cells using pressurized gas for periods ranging from 3 hours to 9 days, and then the system was either slowly (~30 minutes) or rapidly (~5 seconds) depressurized. Cell viability, apoptosis, proliferation, and F-actin distribution were then assayed. Our results did not show significant differences between rapidly and slowly depressurized cells that would explain differences previously reported in the literature. Moreover, we found no detectable effect of elevated hydrostatic pressure (with slow depressurization) on any measured variables. Our results do not confirm the findings of other groups that modest increases in hydrostatic pressure affect cell function, but we are not able to explain their findings.