Sample records for primary eye position

  1. Kinematic principles of primate rotational vestibulo-ocular reflex. II. Gravity-dependent modulation of primary eye position

    NASA Technical Reports Server (NTRS)

    Hess, B. J.; Angelaki, D. E.

    1997-01-01

    The kinematic constraints of three-dimensional eye positions were investigated in rhesus monkeys during passive head and body rotations relative to gravity. We studied fast and slow phase components of the vestibulo-ocular reflex (VOR) elicited by constant-velocity yaw rotations and sinusoidal oscillations about an earth-horizontal axis. We found that the spatial orientation of both fast and slow phase eye positions could be described locally by a planar surface with torsional variation of <2.0 +/- 0.4 degrees (displacement planes) that systematically rotated and/or shifted relative to Listing's plane. In supine/prone positions, displacement planes pitched forward/backward; in left/right ear-down positions, displacement planes were parallel shifted along the positive/negative torsional axis. Dynamically changing primary eye positions were computed from displacement planes. Torsional and vertical components of primary eye position modulated as a sinusoidal function of head orientation in space. The torsional component was maximal in ear-down positions and approximately zero in supine/prone orientations. The opposite was observed for the vertical component. Modulation of the horizontal component of primary eye position exhibited a more complex dependence. In contrast to the torsional component, which was relatively independent of rotational speed, modulation of the vertical and horizontal components of primary position depended strongly on the speed of head rotation (i.e., on the frequency of oscillation of the gravity vector component): the faster the head rotated relative to gravity, the larger was the modulation. Corresponding results were obtained when a model based on a sinusoidal dependence of instantaneous displacement planes (and primary eye position) on head orientation relative to gravity was fitted to VOR fast phase positions. When VOR fast phase positions were expressed relative to primary eye position estimated from the model fits, they were confined approximately to a single plane with a small torsional standard deviation ( approximately 1.4-2.6 degrees). This reduced torsional variation was in contrast to the large torsional spread (well >10-15 degrees ) of fast phase positions when expressed relative to Listing's plane. We conclude that primary eye position depends dynamically on head orientation relative to space rather than being fixed to the head. It defines a gravity-dependent coordinate system relative to which the torsional variability of eye positions is minimized even when the head is moved passively and vestibulo-ocular reflexes are evoked. In this general sense, Listing's law is preserved with respect to an otolith-controlled reference system that is defined dynamically by gravity.

  2. Oculomotor control of primary eye position discriminates between translation and tilt

    NASA Technical Reports Server (NTRS)

    Hess, B. J.; Angelaki, D. E.

    1999-01-01

    We have previously shown that fast phase axis orientation and primary eye position in rhesus monkeys are dynamically controlled by otolith signals during head rotations that involve a reorientation of the head relative to gravity. Because of the inherent ambiguity associated with primary otolith afferent coding of linear accelerations during head translation and tilts, a similar organization might also underlie the vestibulo-ocular reflex (VOR) during translation. The ability of the oculomotor system to correctly distinguish translational accelerations from gravity in the dynamic control of primary eye position has been investigated here by comparing the eye movements elicited by sinusoidal lateral and fore-aft oscillations (0.5 Hz +/- 40 cm, equivalent to +/- 0.4 g) with those during yaw rotations (180 degrees/s) about a vertically tilted axis (23.6 degrees). We found a significant modulation of primary eye position as a function of linear acceleration (gravity) during rotation but not during lateral and fore-aft translation. This modulation was enhanced during the initial phase of rotation when there was concomitant semicircular canal input. These findings suggest that control of primary eye position and fast phase axis orientation in the VOR are based on central vestibular mechanisms that discriminate between gravity and translational head acceleration.

  3. Eye position signals modify vestibulo- and cervico-ocular fast phases during passive yaw rotations in humans.

    PubMed

    Anastasopoulos, D; Mandellos, D; Kostadima, V; Pettorossi, V E

    2002-08-01

    We studied the amplitude, latency, and probability of occurrence of fast phases (FP) in darkness to unpredictable vestibular and/or cervical yaw stimulation in normal human subjects. The rotational stimuli were smoothed trapezoidal motion transients of 14 degrees amplitude and 1.25 s duration. Eye position before stimulus application (initial eye position, IEP) was introduced as a variable by asking the subjects to fixate a spot appearing either straight ahead or at 7 degrees eccentric positions. The recordings demonstrated that the generation of FP during vestibular stimulation was facilitated when the whole-body rotation was directed opposite the eccentric IEP. Conversely, FP were attenuated if the whole-body rotation was directed toward the eccentric IEP; i.e., the FP attenuated if they were made to further eccentric positions. Cervical stimulation-induced FP were small and variable in direction when IEP was directed straight ahead before stimulus onset. Eccentric IEPs resulted in large FP, the direction of which was essentially independent of the neck-proprioceptive stimulus. They tended to move the eye toward the primary position, both when the trunk motion under the stationary head was directed toward or away from the IEP. FP dependence on IEP was evident also during head-on-trunk rotations. No consistent interaction between vestibularly and cervically induced FP was found. We conclude that extraretinal eye position signals are able to modify vestibularly evoked reflexive FP in darkness, aiming at minimizing excursions of the eyes away from the primary position. However, neck-induced FP do not relate to specific tasks of stabilization or visual search. By keeping the eyes near the primary position, FP may permit flexibility of orienting responses to incoming stimuli. This recentering bias for both vestibularly and cervically generated FP may represent a visuomotor optimizing strategy.

  4. Association between eye diagnosis and positive syphilis test results in a large, urban sexually transmitted infection/primary care clinic population.

    PubMed

    Lobo, Ann-Marie; Gao, Yan; Rusie, Laura; Houlberg, Magda; Mehta, Supriya D

    2018-03-01

    In 2015, the Centers for Disease Control and Prevention (CDC) and the American Academy of Ophthalmology (AAO) released clinical advisories on rising cases of ocular syphilis. We examined the association between eye disease and syphilis infection among primary care and sexually transmitted infection (STI) clinic patients attending an urban lesbian, gay, bisexual, transgender (LGBT) health center. We conducted a retrospective medical record review of all patients who underwent syphilis testing at Howard Brown Health between 1 January 2010 and 31 December 2015. Confirmed eye diagnosis was based on International Classification of Diseases, Ninth Revision (ICD-9) diagnosis codes for conjunctivitis, uveitis, keratitis, retinitis, and red eye. Demographic information, syphilis treatment, HIV status, and high-risk behaviors were abstracted. Syphilis diagnosis was defined by available laboratory data (enzyme immunoassay [EIA], rapid plasma reagin [RPR] titer, fluorescent treponemal antibody absorption [FTA-Abs], Treponema pallidum Ab). Multivariable logistic regression with robust variance was used to identify independent associations. During the study period, 71,299 syphilis tests were performed on 30,422 patients. There were 2288 (3.2%) positive syphilis tests. Seventy-seven patients had a confirmed eye diagnosis (0.25%). Patients with eye disease had higher probability of at least one positive syphilis test (33%) compared to those without eye disease (8%) ( p < 0.01). Of patients with eye disease, 77% were men who had sex with men (MSM) and 65% were HIV-positive. Patients with eye disease had 5.97 (95% CI: 3.70, 9.63) higher odds of having syphilis compared to patients without eye disease. When adjusted for age, race, gender/sexual orientation, insurance status, and HIV status, this association between positive syphilis test and eye disease decreased but was still significant (OR 2.00, 95% CI 1.17, 3.41). Patients who present with an eye diagnosis to STI/primary care clinic have a higher probability of positive syphilis tests even after adjusting for other risk factors for syphilis. High-risk patients with eye symptoms should have routine STI testing and in keeping with CDC and AAO recommendations, full ophthalmologic examination.

  5. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    NASA Technical Reports Server (NTRS)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  6. Lamina cribrosa position and Bruch's membrane opening differences between anterior ischemic optic neuropathy and open-angle glaucoma.

    PubMed

    Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J

    2018-06-01

    To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Prelaminar tissue thickness was significantly thinner in primary open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Lamina cribrosa was shallower in both non-arteritic anterior ischemic optic neuropathy and unaffected fellow eyes compared to healthy eyes (P < 0.001 and P = 0.04, respectively). No differences were found in the optic disk area. A forward lamina cribrosa placement and not a smaller disk could be involved in the pathogenesis of non-arteritic anterior ischemic optic neuropathy. A significantly larger Bruch's membrane opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch's membrane opening has been considered a stable reference for disk-related measures.

  7. Combining recessions (nystagmus and strabismus) with tenotomy improved visual function and decreased oscillopsia and diplopia in acquired downbeat nystagmus and in horizontal infantile nystagmus syndrome.

    PubMed

    Wang, Zhong I; Dell'Osso, Louis F; Tomsak, Robert L; Jacobs, Jonathan B

    2007-04-01

    To investigate the effects of combined tenotomy and recession procedures on both acquired downbeat nystagmus and horizontal infantile nystagmus. Patient 1 had downbeat nystagmus with a chin-down (upgaze) position, oscillopsia, strabismus, and diplopia. Asymmetric superior rectus recessions and inferior rectus tenotomies reduced right hypertropia and rotated both eyes downward. Patient 2 had horizontal infantile nystagmus, a 20 degrees left-eye exotropia, and alternating (abducting-eye) fixation. Lateral rectus recessions and medial rectus tenotomies were performed. Horizontal and vertical eye movements were recorded pre- and postsurgically using high-speed digital video. The eXpanded Nystagmus Acuity Function (NAFX) and nystagmus amplitudes and frequencies were measured. Patient 1: The NAFX peak moved from 10 degrees up to primary position where NAFX values improved 17% and visual acuity increased 25%. Vertical NAFX increased across the -10 degrees to +5 degrees vertical range. Primary-position right hypertropia decreased approximately 50%; foveation time per cycle increased 102%; vertical amplitude, oscillopsia, and diplopia were reduced, and frequency was unchanged. Patient 2: Two lateral, narrow high-NAFX regions (due to alternating fixation) became one broad region with a 43% increase in primary position (acuity increased approximately 92.3%). Diplopia amplitude decreased; convergence and gaze holding were improved. Primary-position right exotropia was reduced; foveation time per cycle increased 257%; horizontal-component amplitude decreased 45.7%, and frequency remained unchanged. Combining tenotomy with nystagmus or strabismus recession procedures increased NAFX and visual acuities and reduced diplopia and oscillopsia in downbeat nystagmus and infantile nystagmus.

  8. High-resolution eye tracking using V1 neuron activity

    PubMed Central

    McFarland, James M.; Bondy, Adrian G.; Cumming, Bruce G.; Butts, Daniel A.

    2014-01-01

    Studies of high-acuity visual cortical processing have been limited by the inability to track eye position with sufficient accuracy to precisely reconstruct the visual stimulus on the retina. As a result, studies on primary visual cortex (V1) have been performed almost entirely on neurons outside the high-resolution central portion of the visual field (the fovea). Here we describe a procedure for inferring eye position using multi-electrode array recordings from V1 coupled with nonlinear stimulus processing models. We show that this method can be used to infer eye position with one arc-minute accuracy – significantly better than conventional techniques. This allows for analysis of foveal stimulus processing, and provides a means to correct for eye-movement induced biases present even outside the fovea. This method could thus reveal critical insights into the role of eye movements in cortical coding, as well as their contribution to measures of cortical variability. PMID:25197783

  9. Individual case photogrammetric calibration of the Hirschberg Ratio (HR) for corneal light reflection test strabometry.

    PubMed

    Romano, Paul E

    2006-01-01

    The HR (prism diopters [PD] per mm of corneal light reflection test [CLRT] asymmetry for strabometry) varies in humans from 14 to 24 PD/mm, but is totally unpredictable. Photo(grammetric) HR calibration in (of) each case facilitates acceptable strabometry precision and accuracy. Take 3 flash photos of the patient with both the preferred eye and then the deviating eye fixating straight ahead and then again with the deviation eye fixing at (+/-5-10 PD) the strabismic angle on a metric rule (stick) one meter away from the camera lens (where 1 cm = 1 PD). On these 3 photos, make four precise measurements of the position of the CLR with reference to the limbus: In the deviating eye fixing straight ahead and fixating at the angle of deviation. Divide the mm difference in location into the change in the angle of fixation to determine the HR for this patient at this angle. Then determine the CLR position in both the deviating eye and the fixing eye in the straight ahead primary position picture. Apply the calculated calibrated HR to the asymmetry of the CLRs in primary position to determine the true strabismic deviation. This imaging method insures accurate Hirschberg CLRT strabometry in each case, determining the deviation in "free space", under conditions of normal binocular viewing, uncontaminated by the artifacts or inaccuracies of other conventional strabometric methods or devices. So performed, the Hirschberg CLRT is the gold standard of strabometry.

  10. Tear osmolarity measurements in dry eye related to primary Sjögren's syndrome.

    PubMed

    Utine, Canan Asli; Bıçakçıgil, Müge; Yavuz, Sule; Çiftçi, Ferda

    2011-08-01

    To evaluate the tear osmolarity in patients with dry eye syndrome related to primary Sjögren's Syndrome (SS). Twenty eyes of 10 patients with dry eye and primary SS (Group 1) and 20 eyes of 20 subjects who do not have dry eye syndrome (Group 2) were included in this cross-sectional study. In all eyes, ophthalmic examination was performed in the same order: International Ocular Surface Disease Index survey, visual acuity assessment, conjunctival hyperemia scoring, tear osmolarity measurement with TearLab(™) Osmolarity System, tear film break-up time assessment, corneal fluorescein staining scoring, ocular surface Lissamine Green staining scoring, anesthetized Schirmer test. Dry eye severity was graded according to Dry Eye Workshop (DEWS) classification system. Four eyes with grade 1, four eyes with grade 2, seven eyes with grade 3, and five eyes with grade 4 dryness, according to DEWS system, were included. The mean tear osmolarity value was 301.9 ± 11.40 mOsm/L (range: 290-328) in Group 1, and 294.85 ± 8.33 mOsm/L (range: 283-311) in Group 2 (p = 0.03). In Group 1, tear osmolarity values were positively correlated with OSDI scores (r(18) = 0.55, r(2) = 0.31, p = 0.01), DEWS classification grades (r(18) = 0.73, r(2) = 0.54, p < 0.01), temporal and total corneal staining scores (r(18) = 0.67, r(2) = 0.44, p < 0.01, and r(18) = 0.51, r(2) = 0.26, p = 0.02, respectively), temporal conjunctival staining scores (r(18) = 58, r(2) = 0.34, p < 0.01); and negatively correlated with anesthetized Schirmer test results (r(18) = -0.62, r(2) = 0.38, p < 0.01) and TFBUT (r(18) = -0.50, r(2) = 0.25, p = 0.02). Tear osmolarity values were found to be greater in patients with dry eye syndrome related to primary SS compared to control subjects, and positively correlated with the severity of dry eye.

  11. Effect of eye position on saccades and neuronal responses to acoustic stimuli in the superior colliculus of the behaving cat.

    PubMed

    Populin, Luis C; Tollin, Daniel J; Yin, Tom C T

    2004-10-01

    We examined the motor error hypothesis of visual and auditory interaction in the superior colliculus (SC), first tested by Jay and Sparks in the monkey. We trained cats to direct their eyes to the location of acoustic sources and studied the effects of eye position on both the ability of cats to localize sounds and the auditory responses of SC neurons with the head restrained. Sound localization accuracy was generally not affected by initial eye position, i.e., accuracy was not proportionally affected by the deviation of the eyes from the primary position at the time of stimulus presentation, showing that eye position is taken into account when orienting to acoustic targets. The responses of most single SC neurons to acoustic stimuli in the intact cat were modulated by eye position in the direction consistent with the predictions of the "motor error" hypothesis, but the shift accounted for only two-thirds of the initial deviation of the eyes. However, when the average horizontal sound localization error, which was approximately 35% of the target amplitude, was taken into account, the magnitude of the horizontal shifts in the SC auditory receptive fields matched the observed behavior. The modulation by eye position was not due to concomitant movements of the external ears, as confirmed by recordings carried out after immobilizing the pinnae of one cat. However, the pattern of modulation after pinnae immobilization was inconsistent with the observations in the intact cat, suggesting that, in the intact animal, information about the position of the pinnae may be taken into account.

  12. Kinematics of Visually-Guided Eye Movements

    PubMed Central

    Hess, Bernhard J. M.; Thomassen, Jakob S.

    2014-01-01

    One of the hallmarks of an eye movement that follows Listing’s law is the half-angle rule that says that the angular velocity of the eye tilts by half the angle of eccentricity of the line of sight relative to primary eye position. Since all visually-guided eye movements in the regime of far viewing follow Listing’s law (with the head still and upright), the question about its origin is of considerable importance. Here, we provide theoretical and experimental evidence that Listing’s law results from a unique motor strategy that allows minimizing ocular torsion while smoothly tracking objects of interest along any path in visual space. The strategy consists in compounding conventional ocular rotations in meridian planes, that is in horizontal, vertical and oblique directions (which are all torsion-free) with small linear displacements of the eye in the frontal plane. Such compound rotation-displacements of the eye can explain the kinematic paradox that the fixation point may rotate in one plane while the eye rotates in other planes. Its unique signature is the half-angle law in the position domain, which means that the rotation plane of the eye tilts by half-the angle of gaze eccentricity. We show that this law does not readily generalize to the velocity domain of visually-guided eye movements because the angular eye velocity is the sum of two terms, one associated with rotations in meridian planes and one associated with displacements of the eye in the frontal plane. While the first term does not depend on eye position the second term does depend on eye position. We show that compounded rotation - displacements perfectly predict the average smooth kinematics of the eye during steady- state pursuit in both the position and velocity domain. PMID:24751602

  13. The Prevalence of Dry Eye and Sjögren Syndrome in Patients with Migraine.

    PubMed

    Sarac, Ozge; Kosekahya, Pinar; Yildiz Tasci, Yelda; Keklikoglu, Hava D; Deniz, Orhan; Erten, Şükran; Çağıl, Nurullah

    2017-06-01

    To evaluate the presence of dry eye and primary Sjögren syndrome (SS) in patients with migraine. In total, 46 eyes of 46 patients with migraine (group 1) and 50 eyes of 50 healthy subjects (group 2) were included in this study. Detailed ophthalmologic, neurologic and rheumatologic examination were performed on all participants. Ocular surface disease index questionnaire, tear function tests, visual analog scale for pain, serologic analysis were also performed. Dry eye symptoms and findings were significantly higher and more severe in group 1 when compared with group 2. Primary SS was not found in any of the participants. The migraine lifetime duration was negatively correlated with the tear function tests while it was positively correlated with the ocular surface disease index scores. Dry eye symptoms and findings are higher in migraine patients when compared with the healthy subjects without the presence of Sjögren syndrome.

  14. [Study of corvitin efficiency in primary glaucoma].

    PubMed

    Mykheĭtseva, I M; Kashyntseva, L T; Artemov, O V; Khramenko, N I

    2012-01-01

    There were concluded our results of animal experimental investigation and clinical observation of the quercetin-containing preparation corvitin (C) in primary glaucoma treatment. On the model of disease it is shown for rabbit, that introduction of 0.5 ml 2 % C as factious instillation into the eye a basely decreased eye blood flow was increased twice, mionectic at glaucoma eye hydrodynamics was normalized : the outflow of liquid increased on 58 %, inflow - on 52 %, intraocular pressure went down on 14%. Intravenous inflowing of C brought down expressed of oxidative stress - M[see text]A in blood is decreased on 40 %, level of endothelial dysfunction marker NO is increased on 70 %. On the model of glaucoma for rats C, entered protractedly, showed the neuroprotective actions on the neurons of retina, promoting survivability of ganglion cells, that it is shown on histological preparations. Application C in the clinic of glaucoma (intravenously a 0.5 g of preparation in 100 ml of solution) improved for patients a blood supply in the eye on 25 %, and also rendered a positive antioxidant and metabolic effect. Noted positive influences of C concurrently to important pathogeneses factors such as regional eye blood supply, eye hydrodynamics, oxidative stress, metabolic changes, survival of retina neurons grounds to talk about new strategy of pathogenesis therapy of glaucoma.

  15. Perceptions and understanding of genetics and genetic eye disease and attitudes to genetic testing and gene therapy in a primary eye care setting.

    PubMed

    Ganne, Pratyusha; Garrioch, Robert; Votruba, Marcela

    2015-03-01

    Genetic eye pathology represents a significant percentage of the causes of blindness in industrialized countries. This study explores the level of understanding and perceptions of genetics and inherited eye diseases and the attitudes to genetic testing and gene therapy. The study was conducted in two parts. Participant groups included were: undergraduate students of optometry, primary eye care professionals and members of the general public. A preliminary study aimed to understand perceptions and to explore the level of knowledge about genetics in general, eye genetics and gene therapy. A second survey was designed to explore attitudes to genetic testing and gene therapy. The majority of participants (82%) perceived genetics as an important science. However, none of them showed a high level of understanding of genetics and inherited eye diseases. Undergraduate students and primary eye care professionals were better informed about inherited eye diseases than the general public (p = 0.001). The majority (80%) across all three groups had a positive attitude to genetic testing and gene therapy. There was a lack of knowledge about the genetic services available among all groups of participants. This calls for serious thinking about the level of dissemination of information about genetics and inherited eye diseases. It shows a broadly supportive attitude to genomic medicine among the public. Improving public awareness and education in inherited eye diseases can improve the utility of genetic testing and therapy.

  16. [Webino syndrome caused by meningovascular syphilis. A rare entity with an unexpected cause].

    PubMed

    Rodríguez Calvo de Mora, M; Rodríguez Moreno, G; España Contreras, M

    2014-05-01

    The patient is a 57-year-old obese and hypertensive male. His chief complaints were double vision and dizziness, with mild exodeviation in both eyes in primary gaze position in the ocular motility examination, but more predominant in the left eye. The exotropia was noticeably more evident on the attempted upgaze. On horizontal gaze, the abducting eye deviated fully, but the adducting eye did not cross the midline. Nystagmus in the abducting eye and convergence impairment were found. Pupil size and testing were normal. Ataxia and areflexia were also present. Bilateral internuclear ophthalmoplegia was suspected and imaging and laboratory tests were performed. The CAT scan showed a right occipital hypo-attenuated lesion. In the MRI scan, a mesencephalic subacute ischemic lesion was found, involving the medial rectus sub-nuclei. Blood and cerebrospinal fluid test for syphilis were positive. Bilateral internuclear ophthalmoplegia is a very uncommon -and difficult to diagnose- condition. In the reported case the lesion involved the medial rectus sub-nuclei. This fact could explain the exotropia in the primary gaze position, and supports that is not possible to exclude the involvement of the medial rectus sub-nuclei in the webino syndrome. The rapid identification of the pathology contributed to the better prognosis of the patient. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  17. Primary position and listing's law in acquired and congenital trochlear nerve palsy.

    PubMed

    Straumann, Dominik; Steffen, Heimo; Landau, Klara; Bergamin, Oliver; Mudgil, Ananth V; Walker, Mark F; Guyton, David L; Zee, David S

    2003-10-01

    In ocular kinematics, the primary position (PP) of the eye is defined by the position from which movements do not induce ocular rotations around the line of sight (Helmholtz). PP is mathematically linked to the orientation of Listing's plane. This study was conducted to determine whether PP is affected differently in patients with clinically diagnosed congenital (conTNP) and acquired (acqTNP) trochlear nerve palsy. Patients with unilateral conTNP (n = 25) and acqTNP (n = 9) performed a modified Hess screen test. Three-dimensional eye positions were recorded with dual search coils. PP in eyes with acqTNP was significantly more temporal (mean: 21.2 degrees ) than in eyes with conTNP (6.8 degrees ) or healthy eyes (7.2 degrees ). In the pooled data of all patients, the horizontal location of PP significantly correlated with vertical noncomitance with the paretic eye in adduction (R = 0.59). Using a computer model, PP in acqTNP could be reproduced by a neural lesion of the superior oblique (SO) muscle. An additional simulated overaction of the inferior oblique (IO) muscle moved PP back to normal, as in conTNP. Lengthening the SO and shortening the IO muscles could also simulate PP in conTNP. The temporal displacement of PP in acqTNP is a direct consequence of the reduced force of the SO muscle. The reversal of this temporal displacement of PP, which occurs in some patients with conTNP, can be explained by a secondary overaction of the IO muscle. Alternatively, length changes in the SO and IO muscles, or other anatomic anomalies within the orbit, without a neural lesion, may also explain the difference in location of PP between conTNP and acqTNP.

  18. Coexistence of primary biliary cirrhosis and myasthenia gravis: a case study.

    PubMed

    Horigome, H; Nomura, T; Saso, K; Joh, T; Ohara, H; Akita, S; Sobue, S; Mizuno, Y; Kato, Y; Itoh, M

    2000-01-01

    We present a case that suggests a relationship between primary biliary cirrhosis and myasthenia gravis. A 43-year-old Japanese woman was admitted to the Nagoya City University Medical School, First Department of Internal Medicine with abnormal liver function in August 1991. She had had ptosis of the right eye since 1990. She had not been treated for liver disease. Ptosis of the right eye and hepatomegaly were present. Serum laboratory examinations revealed elevated biliary enzymes and IgM levels; tests were positive for antimitochondrial antibody and antiacetylcholine antibody. Liver histology revealed chronic non-suppurative destructive cholangitis and led to a diagnosis of primary biliary cirrhosis. The tensilon test was positive. Electromyography with repetitive motor nerve stimulation revealed a neuromuscular junction defect; i.e., the primary characteristic of myasthenia gravis. The patient was diagnosed with myasthenia gravis. Although the development of myasthenia gravis has previously been reported in patients with primary biliary cirrhosis during D-penicillamine administration, this is a very rare case of the coexistence of both diseases before such treatment.

  19. Oscillopsia in "inverse latent" infantile nystagmus syndrome.

    PubMed

    Abel, Larry A; Malesic, Linda A

    2007-11-01

    A possibly unique individual with infantile nystagmus syndrome presented with incessant oscillopsia but good stereopsis when viewing binocularly; her nystagmus was greatly reduced with left eye occlusion. We have attempted to explain this and to identify an intervention that preserves binocular vision while maximizing perceptual stability. Eye movements were recorded and analyzed for duration of foveation (% time when the target was on or near the fovea and the eye was moving at < or = 4 degrees /sec) under different viewing conditions. Changes in foveation were compared with the patient's reports of her perceptual stability. In her right gaze null with her right eye fixating, foveation was 52.9%. This fell to 32.3% for the same eye in primary position and to 0.8% when viewing binocularly in primary position. When viewing binocularly oscillopsia was incessant; when viewing with her right eye vision was stable except in left gaze. Prism correction of her phoria greatly reduced her oscillopsia when viewing binocularly while preserving stereopsis; foveation went up to 33.7%. The patient's ability to maintain good foveation only when viewing with her right eye forces her to choose between stereopsis and stable vision. This may result from the rare combination of (1) requiring good foveation for oscillopsia suppression and (2) nystagmus deteriorating under the stress of maintaining binocularity. There may be many other infantile nystagmus syndrome patients who do not develop oscillopsia but may suffer sufficient asthenopia from a phoria to exacerbate their nystagmus.

  20. Head-body righting reflex from the supine position and preparatory eye movements.

    PubMed

    Troiani, Diana; Ferraresi, Aldo; Manni, Ermanno

    2005-05-01

    Saccular and utricular maculae can provide information on the supine static position, considering that both have pronounced curved structures with hair cells having a variety of polarization vectors that enable them to sense an inverted position and thus direct the righting reflex. The vestibular system is essential for the structuring of motor behaviour, senses linear and angular acceleration and has a strong influence on posture and balance at rest, during locomotion and in head body righting reflexes. Using guinea pigs in the supine position with a symmetrical head and trunk position, the ocular position was analysed to ascertain whether any ocular movement that occurred would adopt a spatial deviation indicative of the subsequent head and body righting. The characteristics of the righting reflex (direction, latency, duration and velocity) were analysed in guinea pigs from position signals obtained from search coils implanted in the eye, head and pelvis. The animals were kept in a supine position for a few seconds or even minutes with the eyes in a stable primary position and the head and body symmetrical and immobile. The righting reflex took place either immediately or after a slow deviation of the eyes. In both cases the righting sequence (eyes, head, body) was stereotyped and consistent. The direction of head and body righting was along the longitudinal axis of the animal and was either clockwise or anticlockwise and the direction of righting was related to the direction of the eye deviation. The ocular deviation and the direction of deviation that initiated and determined the direction of the righting reflex could be explained by possible otolithic activation.

  1. Strengthening primary eye care in South Africa: An assessment of services and prospective evaluation of a health systems support package

    PubMed Central

    Lilian, Rivka R.; Railton, Jean; Schaftenaar, Erik; Mabitsi, Moyahabo; Grobbelaar, Cornelis J.; Khosa, N. Sellina; Maluleke, Babra H.; Struthers, Helen E.; McIntyre, James A.

    2018-01-01

    Visual impairment is a significant public health concern, particularly in low- and middle-income countries where eye care is predominantly provided at the primary healthcare (PHC) level, known as primary eye care. This study aimed to perform an evaluation of primary eye care services in three districts of South Africa and to assess whether an ophthalmic health system strengthening (HSS) package could improve these services. Baseline surveys were conducted in Cape Winelands District, Johannesburg Health District and Mopani District at 14, 25 and 36 PHC facilities, respectively. Thereafter, the HSS package, comprising group training, individual mentoring, stakeholder engagement and resource provision, was implemented in 20 intervention sites in Mopani District, with the remaining 16 Mopani facilities serving as control sites. At baseline, less than half the facilities in Johannesburg and Mopani had dedicated eye care personnel or sufficient space to measure visual acuity. Although visual acuity charts were available in most facilities, <50% assessed patients at the correct distance. Median score for availability of nine essential drugs was <70%. Referral criteria knowledge was highest in Cape Winelands and Johannesburg, with poor clinical knowledge across all districts. Several HSS interventions produced successful outcomes: compared to control sites there was a significant increase in the proportion of intervention sites with eye care personnel and resources such as visual acuity charts (p = 0.02 and <0.01, respectively). However, engaging with district pharmacists did not improve availability of essential drugs (p = 0.47). Referral criteria knowledge improved significantly in intervention sites (p<0.01) but there was no improvement in clinical knowledge (p = 0.76). Primary eye care in South Africa faces multiple challenges with regard to organisation of care, resource availability and clinical competence. The HSS package successfully improved some aspects of this care, but further development is warranted together with debate regarding the positioning of eye services at PHC level. PMID:29758069

  2. Detecting eye movements in dynamic environments.

    PubMed

    Reimer, Bryan; Sodhi, Manbir

    2006-11-01

    To take advantage of the increasing number of in-vehicle devices, automobile drivers must divide their attention between primary (driving) and secondary (operating in-vehicle device) tasks. In dynamic environments such as driving, however, it is not easy to identify and quantify how a driver focuses on the various tasks he/she is simultaneously engaged in, including the distracting tasks. Measures derived from the driver's scan path have been used as correlates of driver attention. This article presents a methodology for analyzing eye positions, which are discrete samples of a subject's scan path, in order to categorize driver eye movements. Previous methods of analyzing eye positions recorded in a dynamic environment have relied completely on the manual identification of the focus of visual attention from a point of regard superimposed on a video of a recorded scene, failing to utilize information regarding movement structure in the raw recorded eye positions. Although effective, these methods are too time consuming to be easily used when the large data sets that would be required to identify subtle differences between drivers, under different road conditions, and with different levels of distraction are processed. The aim of the methods presented in this article are to extend the degree of automation in the processing of eye movement data by proposing a methodology for eye movement analysis that extends automated fixation identification to include smooth and saccadic movements. By identifying eye movements in the recorded eye positions, a method of reducing the analysis of scene video to a finite search space is presented. The implementation of a software tool for the eye movement analysis is described, including an example from an on-road test-driving sample.

  3. Assessment of a new hydrophilic acrylic supplementary IOL for sulcus fixation in pseudophakic cadaver eyes

    PubMed Central

    Reiter, N; Werner, L; Guan, J; Li, J; Tsaousis, K T; Mamalis, N; Srinivasan, S

    2017-01-01

    Purpose Management of refractive errors after cataract surgery includes spectacles or contact lens, secondary laser vision correction, intraocular lens (IOL) exchange, or piggyback lens implantation. We evaluated for the first time a single-piece hydrophilic acrylic IOL designed for supplementary sulcus fixation in postmortem pseudophakic human eyes. Methods Pseudophakic human cadaver eyes were imaged by anterior segment optical coherence tomography (AS-OCT) to assess position of the primary IOL. Eyes were prepared as per the Miyake-Apple technique. The supplementary IOL (Medicontur A4 Addon IOL family) was then inserted into the ciliary sulcus. AS-OCT and photographs from anterior and posterior views were used to assess IOL centration, tilt, and interlenticular distance from the primary IOL. Results Data were obtained from 12 eyes having primary IOLs of varying materials and designs in the bag and representing different sizes of eyes and severity of Soemmering's ring formation. The A4 Addon IOL was successfully inserted into the ciliary sulcus and was well centered in all cases. Four cases of tilt were observed on AS-OCT: three with mild tilt due to pre-existing zonular dehiscence, and one due to a localized area of Soemmering's ring formation. Interlenticular distance ranged from 0.34 to 1.24 mm and was not dependent on severity of Soemmering's ring or type of primary IOL. Conclusions The A4 Addon IOL was designed for sulcus fixation as a supplementary lens, with a large diameter, a square-shaped optic, four smooth loop haptics, and a convex–concave optical surface. It exhibited appropriate centration and interlenticular distance with different primary in-the-bag IOLs. PMID:28106890

  4. Effects of tenotomy on patients with infantile nystagmus syndrome: foveation improvement over a broadened visual field.

    PubMed

    Wang, Zhong; Dell'Osso, Louis F; Jacobs, Jonathan B; Burnstine, Robert A; Tomsak, Robert L

    2006-12-01

    To investigate the effects of four-muscle tenotomy on visual function and gaze angle in patients with infantile nystagmus syndrome (INS). Eye movements of nine patients with infantile nystagmus were recorded using infrared reflection or high-speed digital video techniques. Experimental protocols were designed to record the patients' eye-movement waveforms, pre- and post-tenotomy, at different gaze angles. We used the eXpanded Nystagmus Acuity Function (NAFX) to measure tenotomy-induced changes in the nystagmus at primary position and various gaze angles. The longest foveation domains (LFD) were measured from fitted curves. Peak-to-peak nystagmus amplitudes and foveation-period durations were also measured. All measurements were made unmasked. All seven patients with narrow, high-NAFX, gaze-angle regions showed broadening of these regions of higher visual function. Three patients showed moderate NAFX improvement (13.9-32.6%) at primary position, five showed large improvement (39.9-162.4%), and one showed no NAFX change (due to his high pretenotomy NAFX). Primary position measured acuities improved in six patients. All patients had reductions in nystagmus amplitudes ranging from 14.6 to 37%. The duration of the foveation period increased in all nine patients (11.2-200%). The percentage improvements in both the NAFX and the LFD decreased with higher pretenotomy values. In addition to elevating primary position NAFX, tenotomy also broadens the high-NAFX regions. This broadening effect is more prominent in patients who had sharp pretenotomy NAFX peaks. Four-muscle tenotomy produces higher primary position NAFX increases in infantile nystagmus patients whose pretenotomy values are relatively low, with the improvement decreasing at higher pretenotomy values. The tenotomy procedure improves visual function beyond primary position acuity. This extends the utility of surgical therapy to several different classes of patients with INS for whom other procedures are contraindicated. The pretenotomy NAFX can now be used to predict both primary position acuity improvements and broadening of a patient's high-NAFX range of gaze angles.

  5. Conjunctivolimbal Autograft Using a Fibrin Adhesive in Pterygium Surgery

    PubMed Central

    Kim, Hyun Ho; Mun, Hong Jae; Lee, Kyoo Won; Shin, Jae Pil

    2008-01-01

    Purpose To evaluate the efficacy and safety of fibrin bioadhesive in conjunctivolimbal autograft surgery for primary pterygium. Methods Thirty-six eyes in 34 patients were reviewed with nasal primary pterygium who were treated with pterygium excision with superior conjunctivolimbal transplantation with fibrin bioadhesive. Surgical durations were recorded and the patients were followed up on the first day after surgery and then at 1, 2, 4, 8 and 12 weeks postoperatively. The graft-recipient site attachments were examined and subjective symptoms of patients were recorded at every follow-up examinations. Results The mean patient age was 57.9±10.1 (ranging from 33 to 83) years. The mean follow-up period was 22.05±5.78 weeks. The mean surgery time was 18.04±5.65 minutes. The subjective symptoms (pain, foreign body sensation, tearing and discomfort) disappeared in 23 of 36 eyes (64%) in one week after surgery, and all discomforts subsided within two weeks after surgery in all patients. The conjunctivolimbal autograft was correctly positioned and fixed in 34 of 36 eyes (94.4%) throughout the follow-up period. Graft dehiscence was seen in two eyes (5.6%), one eye was treated with remedial sutures, and the other eye showed a spontaneous healing without remedial sutures. Transient graft edema occurred in four eyes (11.2%) but subsided spontaneously within a month. There were no cases of pterygium regrowth or complications due to the fibrin bioadhesive. Conclusions The use of fibrin bioadhesive in conjunctivolimbal autograft surgery in primary pterygium simplifies surgical techniques, shorten surgical duration, and produce less postoperative subjective symptoms. Therefore, the fibrin bioadhesive is a safe and effective tool to attach conjunctivolimbal autograft in primary pterygium surgery. PMID:18784440

  6. Electrophysiological recordings in humans reveal reduced location-specific attentional-shift activity prior to recentering saccades

    PubMed Central

    Boehler, C. Nicolas; Zhang, Helen H.; Schoenfeld, Mircea A.; Woldorff, Marty G.

    2012-01-01

    Being able to effectively explore the visual world is of fundamental importance, and it has been suggested that the straight-ahead gaze position within the egocentric reference frame (“primary position”) might play a special role in this context. In the present study we employed human electroencephalography (EEG) to examine neural activity related to the spatial guidance of saccadic eye movements. Moreover, we sought to investigate whether such activity would be modulated by the spatial relation of saccade direction to the primary gaze position (recentering saccades). Participants executed endogenously cued saccades between five equidistant locations along the horizontal meridian. This design allowed for the comparison of isoamplitude saccades from the same starting position that were oriented either toward the primary position (centripetal) or further away from it (centrifugal). By back-averaging time-locked to the saccade onset on each trial, we identified a parietally distributed, negative-polarity EEG deflection contralateral to the direction of the upcoming saccade. Importantly, this contralateral presaccadic negativity, which appeared to reflect the location-specific attentional guidance of the eye movement, was attenuated for recentering saccades relative to isoamplitude centrifugal saccades. This differential electrophysiological signature was paralleled by faster saccadic reaction times and was substantially more apparent when time-locking the data to the onset of the saccade rather than to the onset of the cue, suggesting a tight temporal association with saccade initiation. The diminished level of this presaccadic component for recentering saccades may reflect the preferential coding of the straight-ahead gaze position, in which both the eye-centered and head-centered reference frames are perfectly aligned and from which the visual world can be effectively explored. PMID:22157127

  7. Optomotor-blind negatively regulates Drosophila eye development by blocking Jak/STAT signaling.

    PubMed

    Tsai, Yu-Chen; Grimm, Stefan; Chao, Ju-Lan; Wang, Shih-Chin; Hofmeyer, Kerstin; Shen, Jie; Eichinger, Fred; Michalopoulou, Theoni; Yao, Chi-Kuang; Chang, Chih-Hsuan; Lin, Shih-Han; Sun, Y Henry; Pflugfelder, Gert O

    2015-01-01

    Organ formation requires a delicate balance of positive and negative regulators. In Drosophila eye development, wingless (wg) is expressed at the lateral margins of the eye disc and serves to block retinal development. The T-box gene optomotor-blind (omb) is expressed in a similar pattern and is regulated by Wg. Omb mediates part of Wg activity in blocking eye development. Omb exerts its function primarily by blocking cell proliferation. These effects occur predominantly in the ventral margin. Our results suggest that the primary effect of Omb is the blocking of Jak/STAT signaling by repressing transcription of upd which encodes the Jak receptor ligand Unpaired.

  8. Primary orbital precursor T-cell lymphoblastic lymphoma: Report of a unique case

    PubMed Central

    Stenman, Lisa; Persson, Marta; Enlund, Fredrik; Clasen-Linde, Erik; Stenman, Göran; Heegaard, Steffen

    2016-01-01

    Primary T-cell lymphoblastic lymphoma (T-LBL) in the eye region is very rare. The present study described a unique case of T-LBL involving the extraocular muscles. A 22-year-old male patient presented with a 3-week history of headache, reduced visual acuity and edema of the left eye. Clinical examination revealed left-sided exophthalmus, periorbital edema, chemosis, and reduced motility of the left eye. A magnetic resonance imaging scan revealed thickening of the left orbital muscles and a positron emission tomography-computed tomography scan also demonstrated activity in a subclavicular lymph node. Histopathological analysis of both lesions revealed infiltration by medium-sized neoplastic lymphoid cells with a high nuclear-cytoplasmic ratio and a high mitotic index. Immunostaining revealed positivity for CD2, CD3, CD99, Tia-1, and GranzymB, and variable positivity for CD4. There was no involvement of the bone marrow. Based on the clinical and histopathological findings, a diagnosis of T-LBL was made. There was no evidence of NOTCH1 mutation or rearrangements of the ETV6 and MLL genes and high-resolution array-based comparative genomic hybridization (arrayCGH) analysis revealed a normal genomic profile. The patient received chemotherapy according to the high-risk NOPHO protocol, followed by myeloablative allogenic bone marrow transplantation. At 35 months after diagnosis, the patient remained in complete first remission, but without light perception on his left eye. To the best of our knowledge, this is the first report of a case of T-LBL involving the extraocular muscles. Although primary T-LBL in the eye region is very rare, our findings demonstrate that lymphoma should be considered in the differential diagnosis of patients with similar symptoms. PMID:27900092

  9. Preschool children's vision screening in New Zealand: a retrospective evaluation of referral accuracy

    PubMed Central

    Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S

    2015-01-01

    Objectives To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Design Retrospective longitudinal study. Methods B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Primary outcome measure Positive predictive value of the preschool vision screening programme. Results Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. Conclusions The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. PMID:26614622

  10. Considerations on the mechanisms of alternating skew deviation in patients with cerebellar lesions.

    PubMed

    Zee, D S

    1996-01-01

    Alternating skew deviation, in which the side of the higher eye changes depending upon whether gaze is directed to the left or the right, is a frequent sign in patients with posterior fossa lesions, including those restricted to the cerebellum. Here we propose a mechanism for alternating skews related to the otolith-ocular responses to fore and aft pitch of the head in lateral-eyed animals. In lateral-eyed animals the expected response to a static head pitch is cyclorotation of the eyes. But if the eyes are rotated horizontally in the orbit, away from the primary position, a compensatory skew deviation should also appear. The direction of the skew would depend upon whether the eyes were directed to the right (left eye forward, right eye backward) or to the left (left eye backward, right eye forward). In contrast, for frontal-eyed animals, skew deviations are counterproductive because they create diplopia and interfere with binocular vision. We attribute the emergence of skew deviations in frontal-eyed animals in pathological conditions to 1) an imbalance in otolithocular pathways and 2) a loss of the component of ocular motor innervation that normally corrects for the differences in pulling directions and strengths of the various ocular muscles as the eyes change position in the orbit. Such a compensatory mechanism is necessary to ensure optimal binocular visual function during and after head motion. This compensatory mechanism may depend upon the cerebellum.

  11. A Case of Blunt Trauma of the Eyeball Associated With an Inferior Oblique Muscle and an Inferior Rectus Muscle Rupture.

    PubMed

    Nitta, Keisuke; Kashima, Tomoyuki; Miura, Fumihide; Hiroe, Takashi; Akiyama, Hideo; Kishi, Shoji

    2016-01-01

    Rupture of the extraocular muscle in the absence of significant injury to the eyeball and adnexa is uncommon. The authors report a case of blunt trauma of the eyeball associated with an inferior oblique muscle and an inferior rectus muscle rupture. A 55-year-old man slipped and fell down hitting his eye on an extended windshield wiper blade. Although he had treatment in the emergency room, he complained of diplopia in the primary position 1 day postoperatively. After noticing ruptures of the inferior oblique muscle and an inferior rectus muscle during exploratory surgery, the authors carefully repaired it. Diplopia in the primary position had disappeared within 1 month after the operation and by 6 months postoperatively. The movement of the eye had almost completely recovered.

  12. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy

    PubMed Central

    Balakrishna, Nagalla

    2017-01-01

    Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student’s t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 pm from scleral spur (AOD 500), trabecular-ciliary process distance (TCPD), iris-ciliary process distance (ICPD), and iris-zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral-iris angle (SIA), and scleral-ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris-lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article: Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy. J Curr Glaucoma Pract 2017;11(3):86-91. PMID:29151682

  13. The effect of an eye health promotion program on the health protective behaviors of primary school students

    PubMed Central

    Kirag, Nukhet; Temel, Ayla Bayik

    2018-01-01

    INTRODUCTION: Undiagnosed and uncorrected refractive errors in childhood can negatively affect the development of vision and cause students to have low academic success and even quit school before graduation. This study aims to determine the effects of an eye health promotion program on the health protective behaviors of primary school students. MATERIALS AND METHODS: This experimental study using a pretest-posttest design with a control group was conducted in three public primary schools in Aydın, a city in the Western Anatolia Region of Turkey, between April and November 2014. The eye health promotion program was provided by the researchers to the experimental Group 2 days in 4 weeks. The data were analyzed using the t-test, Chi-square analysis, the Mann–Whitney U-test, the Wilcoxon signed-rank test, and the McNemar test. RESULTS: The average age of the students was identified as 9.0 ± 3.64 years. The students wearing glasses all in the experimental group and 53.3% in the control group were found to always wear their glasses after the education program was completed (P < 0.05). These students, 97.9% in the experimental group and 58.1% in the control group underwent eye examinations from an ophthalmologist (P < 0.05). The eye health protective behaviors of the experimental group were found to have positively changed in the final follow-up, compared to the control group (P < 0.05). CONCLUSION: The eye health promotion program was found to be effective in improving eye health protective behaviors within the experimental group. PMID:29619388

  14. Blood culture bottles are superior to conventional media for vitreous culture.

    PubMed

    Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada

    2016-08-01

    To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P < 0.00001) and an odds ratio of 3.47 (95% confidence interval 1.92, 6.63). A combination of blood culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  15. Optomotor-Blind Negatively Regulates Drosophila Eye Development by Blocking Jak/STAT Signaling

    PubMed Central

    Tsai, Yu-Chen; Grimm, Stefan; Chao, Ju-Lan; Wang, Shih-Chin; Hofmeyer, Kerstin; Shen, Jie; Eichinger, Fred; Michalopoulou, Theoni; Yao, Chi-Kuang; Chang, Chih-Hsuan; Lin, Shih-Han; Sun, Y. Henry; Pflugfelder, Gert O.

    2015-01-01

    Organ formation requires a delicate balance of positive and negative regulators. In Drosophila eye development, wingless (wg) is expressed at the lateral margins of the eye disc and serves to block retinal development. The T-box gene optomotor-blind (omb) is expressed in a similar pattern and is regulated by Wg. Omb mediates part of Wg activity in blocking eye development. Omb exerts its function primarily by blocking cell proliferation. These effects occur predominantly in the ventral margin. Our results suggest that the primary effect of Omb is the blocking of Jak/STAT signaling by repressing transcription of upd which encodes the Jak receptor ligand Unpaired. PMID:25781970

  16. Treatment of inferior oblique paresis with superior oblique silicone tendon expander.

    PubMed

    Greenberg, Marc F; Pollard, Zane F

    2005-08-01

    Patients with inferior oblique eye muscle paresis may show hypotropia and apparent superior oblique muscle overaction on the side of the presumed weak inferior oblique (IO) muscle. We report 8 such patients successfully treated using unilateral silicone superior oblique (SO) tendon expanders. Eight consecutive cases over the course of 6 years from the authors' private practice are described. None had a history of head trauma or a significant neurologic event. All patients showed IO paresis by 3-step test, with incyclotorsion and SO overacton of the hypotropic (paretic) eye. Forced ductions of the hypotropic eye were normal in all cases, and the vertical strabismus was treated with placement of a 7- mm silicone SO tendon expander in the hypotropic (paretic) eye. Mean preoperative primary position hypotropia was 6.5 prism diopters (PD); mean postoperative was 0.5 PD. Seven of 8 patients had resolution of primary position hypotropia, whereas the eighth was reduced. Mean preoperative SO overaction was 3+; all patients had postoperative resolution of SO overaction. Of 4 patients with preoperative ocular torticollis, mean preoperative head tilt was 9.3 degrees; mean postoperative tilt was 2.9 degrees. Two patients' head tilts had resolved, the other 2 showed improvement. All patients showed preoperative incylclotorsion of the hypotropic (paretic) eye; inclyclotorsion resolved in all patients after the placement of a SO tendon expander. The silicone SO tendon expander effectively restores ocular alignment in IO paresis with apparent SO overaction. Associated ocular torticollis can also be improved.

  17. Goldmann tonometry after hyperopic laser in situ keratomileusis: comparison between retreated and nonretreated patients.

    PubMed

    Sanchis-Gimeno, Juan A; Lleó-Pérez, Antonio; Rahhal, Saleh M; Alonso, Luis

    2004-10-01

    To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/- 2.03 mm Hg (P < 0.001) and 12.67 +/- 2.20 mm Hg (P < 0.001), respectively. No significant differences in mean tonometry were found between retreated and primary LASIK eyes 6 months after surgery (P = 0.537). Decreased tonometric values were found in 20 retreated eyes (90.91%) and in 62 primary LASIK eyes (79.48%). Increased tonometric values higher than 1 mm Hg were found in 3 primary LASIK eyes (3.84%), but no retreated eyes showed increased values 6 months after surgery. Two retreated eyes (9.09%) and 10 primary LASIK eyes (79.49%) presented the same tonometric values before surgery and at the end of the study. After hyperopic laser in situ keratomileusis there was no significant difference in Goldmann applanation tonometry between retreated and primary LASIK eyes.

  18. Adaptation of catch-up saccades during the initiation of smooth pursuit eye movements.

    PubMed

    Schütz, Alexander C; Souto, David

    2011-04-01

    Reduction of retinal speed and alignment of the line of sight are believed to be the respective primary functions of smooth pursuit and saccadic eye movements. As the eye muscles strength can change in the short-term, continuous adjustments of motor signals are required to achieve constant accuracy. While adaptation of saccade amplitude to systematic position errors has been extensively studied, we know less about the adaptive response to position errors during smooth pursuit initiation, when target motion has to be taken into account to program saccades, and when position errors at the saccade endpoint could also be corrected by increasing pursuit velocity. To study short-term adaptation (250 adaptation trials) of tracking eye movements, we introduced a position error during the first catch-up saccade made during the initiation of smooth pursuit-in a ramp-step-ramp paradigm. The target position was either shifted in the direction of the horizontally moving target (forward step), against it (backward step) or orthogonally to it (vertical step). Results indicate adaptation of catch-up saccade amplitude to back and forward steps. With vertical steps, saccades became oblique, by an inflexion of the early or late saccade trajectory. With a similar time course, post-saccadic pursuit velocity was increased in the step direction, adding further evidence that under some conditions pursuit and saccades can act synergistically to reduce position errors.

  19. [Clinical characteristics and surgical treatment of idiopathic congenital nystagmus in 224 patients].

    PubMed

    Ding, J; Zhao, K X; Li, Y P; Ma, H Z; Chen, X; Guo, X; Zhu, L N; Li, N D; Zhang, W

    2016-08-01

    To study clinical characteristics and surgical treatment of idiopathic congenital nystagmus (ICN). A retrospective study was conducted in 224 patients with ICN in Tianjin eye hospital from July 2007 to February 2013. There were 224 patients, 158 (70.54%) males and 66 (29.5%) females, mean age was (11.6±8.4) years and (11.4±6.4) years separately. Horizontal nystgamus happened in 215 cases, 3 cases were vertical type and 6 cases were mixed. 214 cases were with no history of operation and 10 patients had ever underwent surgeries before. Furthermore, 151 patients combined with strabismus and refractive error, anterior segment or retinal disorders, which accounting for 67.4% of all the patients. 48 patients were associated myopia, 30 patients with hyperopia, 43 patients with strabismus. Among them, 153 cases of compensatory head position direction were horizontal with face turn, 43 cases (43/153, 28.1%) showed face turning to the left, 110 cases (110/153, 71.9%) showed face turning to the right. Surgeries were designed according to the compensatory head position and head retroversion angle. For 15 patients with double intermediate zones, the position which was often used with good visual function was chosen for operation design. As for the patients with nystagmus and strabismus, the transfer null zone to primary position for the dominant eye and strabismus surgery for the other eye was chosen. And for complicated patients with compensative head position, the dominant head posture were designed for surgery. ICN is dominated by male with variable clinical manifestations. Surgical choice for ICN depends on the direction of head position and if there is strabismus accompanying it.The aim of ocular muscle surgery is to transfer null zone to primary position. (Chin J Ophthalmol, 2016, 52: 574-578).

  20. The Prospective Health Assessment of Cataract Patients’ Ocular Surface (PHACO) study: the effect of dry eye

    PubMed Central

    Trattler, William B; Majmudar, Parag A; Donnenfeld, Eric D; McDonald, Marguerite B; Stonecipher, Karl G; Goldberg, Damien F

    2017-01-01

    Purpose To determine the incidence and severity of dry eye as determined by the International Task Force (ITF) scale in patients being screened for cataract surgery. Patients and methods This was a prospective, multi-center, observational study of 136 patients, at least 55 years of age, who were scheduled to undergo cataract surgery. The primary outcome measure was the incidence of dry eye as evaluated by grade on the ITF scale and secondary outcome measures include tear break-up time (TBUT), ocular surface disease index score, corneal staining with fluorescein, conjunctival staining with lissamine green, and a patient questionnaire to evaluate symptoms of dry eye. Results Mean patient age was 70.7 years. A total of 73.5% of patients were Caucasian and 50% were female. Almost 60% had never complained of a foreign body sensation; only 13% complained of a foreign body sensation half or most of the time. The majority of patients (62.9%) had a TBUT ≤5 seconds, 77% of eyes had positive corneal staining and 50% of the eyes had positive central corneal staining. Eighteen percent had Schirmer’s score with anesthesia ≤5 mm. Conclusion The incidence of dry eye in patients scheduled to undergo cataract surgery in a real-world setting is higher than anticipated. PMID:28848324

  1. Association of IL-21 cytokine with severity of primary Sjögren syndrome dry eye.

    PubMed

    Lim, Sung A; Nam, Doo Hyun; Lee, Jee Hye; Kwok, Seung-Ki; Park, Sung-Hwan; Chung, So-Hyang

    2015-03-01

    IL-21 plays an important role in primary Sjögren syndrome (SS) pathogenesis. The purpose of this study was to evaluate IL-21 expression in tears and the conjunctiva and to analyze the impact of IL-21 on primary SS dry eyes. Eighty subjects were enrolled in this study: 30 patients with primary SS dry eye (30 eyes); 30 patients with non-SS dry eye (30 eyes), and 20 normal controls. Tear IL-21 levels were measured by flow cytometry, and IL-21 gene expression in the conjunctiva from impression cytology was evaluated by quantitative polymerase chain reaction. Ocular Surface Disease Index, tear film breakup time, Schirmer I test, and ocular surface staining scores were obtained for all patients. Primary SS dry eyes had significantly higher tear IL-21 levels than non-SS dry eyes and normal controls (P < 0.01). In addition, IL-21 gene expression in the conjunctiva was also higher in primary SS dry eyes than in non-SS dry eyes and normal controls (P < 0.01). However, there were no significant differences in IL-21 expression in tears and the conjunctiva between non-SS dry eyes and controls. The tear IL-21 level was significantly correlated with ocular surface stain scores (r = 0.54, P < 0.01) and Schirmer I test values (r = -0.23, P < 0.05) in primary SS dry eyes. Our findings suggest that severity of primary SS dry eye is associated with IL-21.

  2. Non-verbal communication between primary care physicians and older patients: how does race matter?

    PubMed

    Stepanikova, Irena; Zhang, Qian; Wieland, Darryl; Eleazer, G Paul; Stewart, Thomas

    2012-05-01

    Non-verbal communication is an important aspect of the diagnostic and therapeutic process, especially with older patients. It is unknown how non-verbal communication varies with physician and patient race. To examine the joint influence of physician race and patient race on non-verbal communication displayed by primary care physicians during medical interviews with patients 65 years or older. Video-recordings of visits of 209 patients 65 years old or older to 30 primary care physicians at three clinics located in the Midwest and Southwest. Duration of physicians' open body position, eye contact, smile, and non-task touch, coded using an adaption of the Nonverbal Communication in Doctor-Elderly Patient Transactions form. African American physicians with African American patients used more open body position, smile, and touch, compared to the average across other dyads (adjusted mean difference for open body position = 16.55, p < 0.001; smile = 2.35, p = 0.048; touch = 1.33, p < 0.001). African American physicians with white patients spent less time in open body position compared to the average across other dyads, but they also used more smile and eye gaze (adjusted mean difference for open body position = 27.25, p < 0.001; smile = 3.16, p = 0.005; eye gaze = 17.05, p < 0.001). There were no differences between white physicians' behavior toward African American vs. white patients. Race plays a role in physicians' non-verbal communication with older patients. Its influence is best understood when physician race and patient race are considered jointly.

  3. [Fundus fluorescein angiography in metastatic choroidal carcinomas and differentiating metastatic choroidal carcinomas from primary choroidal melanomas].

    PubMed

    Li, Lei; Wang, Wen-Ji; Chen, Rong-Jia; Qian, Jiang; Luo, Chuan-Qi; Zhang, Yong-Jin; Shen, Ying; Ye, Xiao-Feng; Gao, Qiao-Yun

    2011-01-01

    To investigate the characteristics of fundus fluorescein angiography (FFA) in metastatic choroidal carcinomas and determine the value of FFA in differentiating metastatic choroidal carcinomas from primary choroidal melanomas. It was a retrospective case series. The retrospective analysis of clinical data and FFA findings was performed in 23 eyes of 22 patients with metastatic choroidal carcinomas and 31 eyes of 31 patients with primary choroidal melanomas as the control. Ocular fundus findings of metastatic choroidal carcinomas were divided into three types: solitary flat (tumor thickness less than 3 mm), solitary elevated (tumor thickness more than 3 mm) or diffuse type. FFA of the three types showed hypofluorescence during the arterial phase and progressive hyperfluorescence during the subsequent phases. The border of the lesions revealed retinal capillary dilation during the arteriovenous phase and persistent pinpoint leakage throughout the angiogram. Retinal capillary dilation and pinpoint leakage were more frequently presented in the solitary flat type. Simultaneous visualization of retinal and tumor circulation (the so called double circulation) was more frequently presented in the solitary elevated type. Pinpoint leakage could be detected in 17 (73.91%) eyes of metastatic choroidal carcinomas and in 5 (16.13%) eyes of primary choroidal melanomas. The difference between the visibility of pinpoint leakage in metastatic choroidal carcinomas and primary choroidal melanomas was statistically significant (P = 0.0000). When pinpoint leakage of FFA was used to differentiate metastatic choroidal carcinomas from primary choroidal melanomas, the sensitivity, specificity, accuracy, positive and negative predictive values were 73.91%, 83.87%, 79.63%, 77.27%, 81.25% respectively. FFA is helpful for the diagnosis of metastatic choroidal carcinomas. Pinpoint leakage on the border of lesions has some value in differentiating metastatic choroidal carcinomas from primary choroidal melanomas.

  4. Internally-generated error signals in monkey frontal eye field during an inferred motion task

    PubMed Central

    Ferrera, Vincent P.; Barborica, Andrei

    2010-01-01

    An internal model for predictive saccades in frontal cortex was investigated by recording neurons in monkey frontal eye field during an inferred motion task. Monkeys were trained to make saccades to the extrapolated position of a small moving target that was rendered temporarily invisible and whose trajectory was altered. On roughly two-thirds of the trials, monkeys made multiple saccades while the target was invisible. Primary saccades were correlated with extrapolated target position. Secondary saccades significantly reduced residual errors resulting from imperfect accuracy of the first saccade. These observations suggest that the second saccade was corrective. As there was no visual feedback, corrective saccades could only be driven by an internally generated error signal. Neuronal activity in the frontal eye field was directionally tuned prior to both primary and secondary saccades. Separate subpopulations of cells encoded either saccade direction or direction error prior to the second saccade. These results suggest that FEF neurons encode the error after the first saccade, as well as the direction of the second saccade. Hence, FEF appears to contribute to detecting and correcting movement errors based on internally generated signals. PMID:20810882

  5. Total ocular, anterior corneal and lenticular higher order aberrations in hyperopic, myopic and emmetropic eyes.

    PubMed

    Philip, Krupa; Martinez, Aldo; Ho, Arthur; Conrad, Fabian; Ale, Jit; Mitchell, Paul; Sankaridurg, Padmaja

    2012-01-01

    Total ocular higher order aberrations and corneal topography of myopic, emmetropic and hyperopic eyes of 675 adolescents (16.9 ± 0.7 years) were measured after cycloplegia using COAS aberrometer and Medmont videokeratoscope. Corneal higher order aberrations were computed from the corneal topography maps and lenticular (internal) higher order aberrations derived by subtraction of corneal aberrations from total ocular aberrations. Aberrations were measured for a pupil diameter of 5mm. Multivariate analysis of variance followed by multiple regression analysis found significant difference in the fourth order aberrations (SA RMS, primary spherical aberration coefficient) between the refractive error groups. Hyperopic eyes (+0.083 ± 0.05 μm) had more positive total ocular primary spherical aberration compared to emmetropic (+0.036 ± 0.04 μm) and myopic eyes (low myopia=+0.038 ± 0.05 μm, moderate myopia=+0.026 ± 0.06 μm) (p<0.05). No difference was observed for the anterior corneal spherical aberration. Significantly less negative lenticular spherical aberration was observed for the hyperopic eyes (-0.038 ± 0.05 μm) than myopic (low myopia=-0.088 ± 0.04 μm, moderate myopia=-0.095 ± 0.05 μm) and emmetropic eyes (-0.081 ± 0.04 μm) (p<0.05). These findings suggest the existence of differences in the characteristics of the crystalline lens (asphericity, curvature and gradient refractive index) of hyperopic eyes versus other eyes. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  6. Intraocular pressure and superior ophthalmic vein blood flow velocity in Graves' orbitopathy: relation with the clinical features.

    PubMed

    Konuk, Onur; Onaran, Zafer; Ozhan Oktar, Suna; Yucel, Cem; Unal, Mehmet

    2009-11-01

    The aim of this study is to evaluate the association of intraocular pressure (IOP) and superior ophthalmic vein blood flow velocity (SOV-BFV) with the clinical features of Graves' orbitopathy. During the 2002-2007 period, 66 eyes of 34 Graves' orbitopathy cases were classified as mild, moderate and severe orbital disease, and evaluated according to their clinical features as: i)type 1 vs type 2 cases, and ii) cases with or without dysthyroid optic neuropathy. In all patients, a full ophthalmic examination including IOP and Hertel measurements was performed. SOV-BFV was analyzed with color Doppler sonography. The Hertel value, IOP in primary and upgaze position were higher, and SOV-BFV was lower in moderate and severe Graves' orbitopathy cases that showed statistical significance from mild cases, and controls (p = 0.001). Moderate and severe Graves' orbitopathy cases showed comparable Hertel measures and IOP in primary and upgaze position (p = 0.39); however, SOV-BFV was significantly lower in severe cases when compared to moderate cases (p = 0.001).This study demonstrated statistically significant negative correlation between IOP in both primary (r = 0.43,p = 0.008) and upgaze position (r = 0.51,p = 0.002), and SOV-BFV. Additionally, statistically significant positive correlation was detected between Hertel values and SOV-BFV(r = 0.402,p = 0.007).There was a statistical difference between type 1 and 2 cases in Hertel values(p = 0.006), IOP in upgaze position (p = 0.026) and SOV-BFV (p = 0.003). SOV-BFV of the eyes showing dysthyroid optic neuropathy was statistically lower than eyes without dysthyroid optic neuropathy (p = 0.006). IOP and SOV-BFV have significant association with the clinical features of Graves' orbitopathy. The decrease in SOV-BFV increases the severity of Graves' orbitopathy, and may have a role in the clinical course of dysthyroid optic neuropathy.

  7. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients

    PubMed Central

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Background Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Methods Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. Results The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40–69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008–2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months’ supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Conclusion Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies. PMID:24179335

  8. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients.

    PubMed

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40-69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008-2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months' supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies.

  9. [Clinical evaluation of the effectiveness of cholinesterase inhibition with neuromidin in the treatment of primary glaucoma patients].

    PubMed

    Zakharova, I A; Avdeev, R V; Pristavka, V A; Surnin, S N; Makhmutov, V Yu; Savrasova, I I

    to investigate neuromidin effectiveness in the treatment of patients with primary glaucoma and compensated intraocular pressure (IOP). A total of 40 patients (80 eyes) were examined. Of them, 10 eyes with early glaucoma, 36 eyes with moderate-stage glaucoma, 33 eyes with advanced glaucoma, and 1 eye with end-stage glaucoma. In 19 eyes, IOP was controlled through beta-blockers, in 11 eyes - through carbonic anhydrase inhibitors, in 10 eyes - through prostaglandin analogues, and in 39 eyes - through combination drugs. Twenty-six eyes had received glaucoma surgery some time earlier. Ipidacrine was prescribed in tablets at 20 mg 2 times daily for 25 days. Treatment effectiveness was judged by visual functions, hydrodynamics, and morphometric parameters of the optic disc. In moderate-stage eyes, visual acuity improved in 66.6% of cases and remained unchanged in 33.3%. In advanced-stage eyes, visual acuity improved in 51.5% of cases and remained unchanged in 48.5%. Visual field broadened in all cases. Moreover, under the neuromidin therapy, the number of scotomas in early-stage eyes decreased, while the number of areas with normal sensitivity of the retina increased by 14.9%. In advanced-stage glaucoma, the effect was less pronounced: the number of type 1 and type 2 scotomas decreased by 3.0±0.6% and 2.9±0.8%, respectively; the number of absolute scotomas did not change; the number of areas with normal sensitivity of the retina increased by 7.4±2.0%. Also, P0 was found to be reduced and intraocular fluid outflow - activated. In early and moderate glaucoma, there was a significant reduction in the cup area as well as an increase in the neuroretinal rim area and retinal nerve fiber layer thickness. In advanced-stage cases, it was only the retinal nerve fiber layer thickness that changed. Neuromidin has a positive impact on visual function, hydrodynamics, and morphometric parameters of the optic disc.

  10. Tumor vascularity and hematogenous metastasis in experimental murine intraocular melanoma.

    PubMed Central

    Grossniklaus, H E

    1998-01-01

    PURPOSE: The purpose of this study is to test the hypothesis that primary tumor vascularity in a murine model of intraocular melanoma positively correlates with the development and hematogenous spread of metastasis. METHODS: Forty 12-week-old C57BL6 mice were inoculated in either the anterior chamber (AC) or posterior compartment (PC) of 1 eye with 5 x 10(5) cells/microL of Queens tissue culture melanoma cells. The inoculated eye was enucleated at 2 weeks; the mice were sacrificed at 4 weeks postinoculation, and necropsies were performed. The enucleated eyes were examined for histologic and ultrastructural features, including relationship of tumor cells to tumor vascular channels, vascular pattern, and mean vascular density. RESULTS: Melanoma grew and was confined to the eye in 12 of 20 AC eyes and 10 of 20 PC eyes. Histologic and electron microscopic examination showed tumor invasion into vascular channels. Five of 12 AC tumors (42%) and 8 of 10 PC tumors (80%) metastasized. All of the AC tumors, but none of the PC tumors, that distantly metastasized also metastasized to ipsilateral cervical lymph nodes (P = .00535). There was no statistically significant difference of vascular pattern between the melanomas that did and did not metastasize to lungs in the PC group (P = .24), although there was a significant difference in the AC group (P = .02). Tumors with high-grade vascular patterns were more likely to metastasize than tumors with low-grade vascular patterns in the AC group. The mean vascular density positively correlated with the presence and number of metastases in both groups (P = .0000 and P < .001, respectively). There was no statistically significant difference of vascular pattern and mean vascular density for AC versus PC melanoma (P = .97). CONCLUSIONS: The rate of metastasis in this murine intraocular melanoma model positively correlates with primary tumor vascularity. The melanoma metastasizes via invasion of tumor vascular channels. AC melanoma also metastasizes through regional lymphatics. Images FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 FIGURE 13 FIGURE 14 FIGURE 15 FIGURE 16 PMID:10360307

  11. [Pathogenetic relationship between pterygium and dry eye syndrome (clinical and cytological study)].

    PubMed

    Petraevskiĭ, A V; Trishkin, K S

    2014-01-01

    To study the prevalence of dry eye syndrome in patients with initial primary pterygium for determination of a possible pathogenetic role of dry eye syndrome in the development of pterygium. 30 patients with initial primary pterygium; besides conventional ophthalmic assessment, cytological examination of bulbar conjunctiva was performed in all cases. Signs of dry eye syndrome, of similar severity in both eyes, were found in 100% of patients. Dry eye can be one of the precipitating factors of primary pterygium.

  12. Pilot randomised controlled trial of face-down positioning following macular hole surgery.

    PubMed

    Lange, C A K; Membrey, L; Ahmad, N; Wickham, L; Maclaren, R E; Solebo, L; Xing, W; Bunce, C; Ezra, E; Charteris, D; Aylward, B; Yorston, D; Gregor, Z; Zambarakji, H; Bainbridge, J W

    2012-02-01

    This was a pilot randomised controlled trial (RCT) to investigate the effect of post-operative face-down positioning on the outcome of macular hole surgery and to inform the design of a larger definitive study. In all, 30 phakic eyes of 30 subjects with idiopathic full-thickness macular holes underwent vitrectomy with dye-assisted peeling of the ILM and 14% perfluoropropane gas. Subjects were randomly allocated to posture face down for 10 days (posturing group) or to avoid a face-up position only (non-posturing group). The primary outcome was anatomical hole closure. Macular holes closed in 14 of 15 eyes (93.3%; 95% confidence interval (CI) 68-100%) in the posturing group and in 9 of 15 (60%; 95% CI 32-84%) in the non-posturing group. In a subgroup analysis of outcome according to macular hole size, all holes smaller than 400 μm closed regardless of posturing (100%). In contrast, holes larger than 400 μm closed in 10 of 11 eyes (91%; 95% CI 58-99%) in the posturing group and in only 4 of 10 eyes (40%; 95% CI 12-74%) in the non-posturing group (Fisher's exact test P=0.02). Post-operative face-down positioning may improve the likelihood of macular hole closure, particularly for holes larger than 400 μm. These results support the case for a RCT.

  13. [The 8-year follow-up study for clinical diagnostic potentials of frequency-doubling technology perimetry for perimetrically normal eyes of open-angle glaucoma patients with unilateral visual field loss].

    PubMed

    Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F

    2018-03-11

    Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two-sample test, P= 0.011) and more eyes with glaucomatous optic neuropathy (19/22 vs . 4/11, Fisher exact test, P= 0.006). Conclusions: In perimetrically normal eyes of OAG patients, FDP could detect visual field loss of these eyes and predict to some extent future visual field loss on SAP. Severity of glaucomatous optic neuropathy at baseline is related to converting from abnormalities on FDP to visual field loss on SAP. (Chin J Ophthalmol, 2018, 54: 177-183) .

  14. Binocular Neurons in Parastriate Cortex: Interocular ‘Matching’ of Receptive Field Properties, Eye Dominance and Strength of Silent Suppression

    PubMed Central

    Wang, Chun; Dreher, Bogdan

    2014-01-01

    Spike-responses of single binocular neurons were recorded from a distinct part of primary visual cortex, the parastriate cortex (cytoarchitectonic area 18) of anaesthetized and immobilized domestic cats. Functional identification of neurons was based on the ratios of phase-variant (F1) component to the mean firing rate (F0) of their spike-responses to optimized (orientation, direction, spatial and temporal frequencies and size) sine-wave-luminance-modulated drifting grating patches presented separately via each eye. In over 95% of neurons, the interocular differences in the phase-sensitivities (differences in F1/F0 spike-response ratios) were small (≤0.3) and in over 80% of neurons, the interocular differences in preferred orientations were ≤10°. The interocular correlations of the direction selectivity indices and optimal spatial frequencies, like those of the phase sensitivies and optimal orientations, were also strong (coefficients of correlation r ≥0.7005). By contrast, the interocular correlations of the optimal temporal frequencies, the diameters of summation areas of the excitatory responses and suppression indices were weak (coefficients of correlation r ≤0.4585). In cells with high eye dominance indices (HEDI cells), the mean magnitudes of suppressions evoked by stimulation of silent, extra-classical receptive fields via the non-dominant eyes, were significantly greater than those when the stimuli were presented via the dominant eyes. We argue that the well documented ‘eye-origin specific’ segregation of the lateral geniculate inputs underpinning distinct eye dominance columns in primary visual cortices of mammals with frontally positioned eyes (distinct eye dominance columns), combined with significant interocular differences in the strength of silent suppressive fields, putatively contribute to binocular stereoscopic vision. PMID:24927276

  15. Combined lateral rectus augmented transposition and inferior rectus recession for monocular elevation deficiency.

    PubMed

    Jayakumar, Manjula; Kumar, Dhivya Ashok; Agarwal, Amar

    2018-04-01

    We report the case of a 21-year-old woman who presented with a drooping right upper eyelid and smaller-appearing right eye, evident since birth. Her visual acuity was 20/30 in the right eye and 20/20 in the left eye. In primary gaze she had a hypotropia of 25 Δ , with a marked elevation limitation and associated true upper lid ptosis of 3 mm. Under local anesthesia, the lateral rectus muscle was transposed to the superior rectus muscle and was augmented by a nonabsorbable suture attaching the superior rectus muscle and lateral rectus muscle 8 mm posterior to the insertion, accompanied by an inferior rectus recession. One year after surgery she was orthophoric in primary position and showed improvement in elevation. The surgical procedure can be performed at the same time as the inferior rectus recession and reduces the risk of anterior segment ischemia. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  16. Genetic mechanisms involved in the evolution of the cephalopod camera eye revealed by transcriptomic and developmental studies

    PubMed Central

    2011-01-01

    Background Coleoid cephalopods (squids and octopuses) have evolved a camera eye, the structure of which is very similar to that found in vertebrates and which is considered a classic example of convergent evolution. Other molluscs, however, possess mirror, pin-hole, or compound eyes, all of which differ from the camera eye in the degree of complexity of the eye structures and neurons participating in the visual circuit. Therefore, genes expressed in the cephalopod eye after divergence from the common molluscan ancestor could be involved in eye evolution through association with the acquisition of new structural components. To clarify the genetic mechanisms that contributed to the evolution of the cephalopod camera eye, we applied comprehensive transcriptomic analysis and conducted developmental validation of candidate genes involved in coleoid cephalopod eye evolution. Results We compared gene expression in the eyes of 6 molluscan (3 cephalopod and 3 non-cephalopod) species and selected 5,707 genes as cephalopod camera eye-specific candidate genes on the basis of homology searches against 3 molluscan species without camera eyes. First, we confirmed the expression of these 5,707 genes in the cephalopod camera eye formation processes by developmental array analysis. Second, using molecular evolutionary (dN/dS) analysis to detect positive selection in the cephalopod lineage, we identified 156 of these genes in which functions appeared to have changed after the divergence of cephalopods from the molluscan ancestor and which contributed to structural and functional diversification. Third, we selected 1,571 genes, expressed in the camera eyes of both cephalopods and vertebrates, which could have independently acquired a function related to eye development at the expression level. Finally, as experimental validation, we identified three functionally novel cephalopod camera eye genes related to optic lobe formation in cephalopods by in situ hybridization analysis of embryonic pygmy squid. Conclusion We identified 156 genes positively selected in the cephalopod lineage and 1,571 genes commonly found in the cephalopod and vertebrate camera eyes from the analysis of cephalopod camera eye specificity at the expression level. Experimental validation showed that the cephalopod camera eye-specific candidate genes include those expressed in the outer part of the optic lobes, which unique to coleoid cephalopods. The results of this study suggest that changes in gene expression and in the primary structure of proteins (through positive selection) from those in the common molluscan ancestor could have contributed, at least in part, to cephalopod camera eye acquisition. PMID:21702923

  17. Auditory, Vestibular and Cognitive Effects due to Repeated Blast Exposure on the Warfighter

    DTIC Science & Technology

    2012-10-01

    Gaze Horizontal (Left and Right) Description: The primary purpose of the Gaze Horizontal subtest was to detect nystagmus when the head is fixed and...to detect nystagmus when the head is fixed and the eyes are gazing off center from the primary (straight ahead) gaze position. This test is designed...physiological target area and examiner instructions for testing): Spontaneous Nystagmus Smooth Harmonic Acceleration (.01, .08, .32, .64, 1.75

  18. Three-dimensional organization of otolith-ocular reflexes in rhesus monkeys. I. Linear acceleration responses during off-vertical axis rotation

    NASA Technical Reports Server (NTRS)

    Angelaki, D. E.; Hess, B. J.

    1996-01-01

    1. The dynamic properties of otolith-ocular reflexes elicited by sinusoidal linear acceleration along the three cardinal head axes were studied during off-vertical axis rotations in rhesus monkeys. As the head rotates in space at constant velocity about an off-vertical axis, otolith-ocular reflexes are elicited in response to the sinusoidally varying linear acceleration (gravity) components along the interaural, nasooccipital, or vertical head axis. Because the frequency of these sinusoidal stimuli is proportional to the velocity of rotation, rotation at low and moderately fast speeds allows the study of the mid-and low-frequency dynamics of these otolith-ocular reflexes. 2. Animals were rotated in complete darkness in the yaw, pitch, and roll planes at velocities ranging between 7.4 and 184 degrees/s. Accordingly, otolith-ocular reflexes (manifested as sinusoidal modulations in eye position and/or slow-phase eye velocity) were quantitatively studied for stimulus frequencies ranging between 0.02 and 0.51 Hz. During yaw and roll rotation, torsional, vertical, and horizontal slow-phase eye velocity was sinusoidally modulated as a function of head position. The amplitudes of these responses were symmetric for rotations in opposite directions. In contrast, mainly vertical slow-phase eye velocity was modulated during pitch rotation. This modulation was asymmetric for rotations in opposite direction. 3. Each of these response components in a given rotation plane could be associated with an otolith-ocular response vector whose sensitivity, temporal phase, and spatial orientation were estimated on the basis of the amplitude and phase of sinusoidal modulations during both directions of rotation. Based on this analysis, which was performed either for slow-phase eye velocity alone or for total eye excursion (including both slow and fast eye movements), two distinct response patterns were observed: 1) response vectors with pronounced dynamics and spatial/temporal properties that could be characterized as the low-frequency range of "translational" otolith-ocular reflexes; and 2) response vectors associated with an eye position modulation in phase with head position ("tilt" otolith-ocular reflexes). 4. The responses associated with two otolith-ocular vectors with pronounced dynamics consisted of horizontal eye movements evoked as a function of gravity along the interaural axis and vertical eye movements elicited as a function of gravity along the vertical head axis. Both responses were characterized by a slow-phase eye velocity sensitivity that increased three- to five-fold and large phase changes of approximately 100-180 degrees between 0.02 and 0.51 Hz. These dynamic properties could suggest nontraditional temporal processing in utriculoocular and sacculoocular pathways, possibly involving spatiotemporal otolith-ocular interactions. 5. The two otolith-ocular vectors associated with eye position responses in phase with head position (tilt otolith-ocular reflexes) consisted of torsional eye movements in response to gravity along the interaural axis, and vertical eye movements in response to gravity along the nasooccipital head axis. These otolith-ocular responses did not result from an otolithic effect on slow eye movements alone. Particularly at high frequencies (i.e., high speed rotations), saccades were responsible for most of the modulation of torsional and vertical eye position, which was relatively large (on average +/- 8-10 degrees/g) and remained independent of frequency. Such reflex dynamics can be simulated by a direct coupling of primary otolith afferent inputs to the oculomotor plant. (ABSTRACT TRUNCATED).

  19. Uveal effusion following acute primary angle-closure: a retrospective case series

    PubMed Central

    Yang, Jian-Gang; Li, Jian-Jun; Tian, Hua; Li, Yan-Hong; Gong, Yu-Jing; Su, An-Le; He, Na

    2017-01-01

    AIM To evaluate the morphological changes in anterior segment in Chinese patients with uveal effusion (UE) after the attack of acute primary angle-closure (APAC) using ultrasound biomicroscopy (UBM), and to assess the clinical course and prognosis of the disease. METHODS In a retrospective case series, 26 eyes in 26 consecutive patients diagnosed with UE after the treatment of intraocular pressure (IOP)-lowering medication for the attack of APAC were enrolled. The unaffected fellow eyes served as controls. The morphological changes were observed by ultrasonography, slit lamp microscopy and gonioscopy. UBM was used to assess the degree and extent of effusion based on the analysis of parameters associated with UE. RESULTS The mean IOP was 9.2 (SD 2.1) mm Hg at the diagnosis of UE after IOP-lowering medication, while 14.1 (SD, 2.6) mm Hg in the fellow eyes (P=0.000). The anterior chamber depth (ACD) (P=0.000), angle opening distance at 500 µm (AOD500) (P<0.01) and anterior chamber angle (ACA) (P<0.05) were decreased significantly, while ciliary body thickness (CBT) (P<0.05) increased significantly in UE eyes. UE grade analysis showed 7 eyes in grade 1, 9 eyes in grade 2, and 10 eyes in grade 3. Quadrant scores were performed of 4 eyes in 1 quadrant, 3 eyes in 3 quadrants, and 19 eyes in 4 quadrants. There was the positive correlation between grade and quadrant score (r=0.644, P=0.000). The effusion on all eyes were recovered after medication, which mean IOP was 13.9 (SD, 2.8) mm Hg. CONCLUSION UE is a frequent complication in Chinese patients after the attack of APAC, partially associated with hypotony. The severity of UE is correlation with height of effusion, extent of detachment, and shallower ACD. PMID:28393032

  20. Effect of primary iris and ciliary body cyst on anterior chamber angle in patients with shallow anterior chamber*

    PubMed Central

    Wang, Bing-hong; Yao, Yu-feng

    2012-01-01

    Objective: To evaluate the prevalence of primary iris and/or ciliary body cysts in eyes with shallow anterior chamber and their effect on the narrowing of the anterior chamber angle. Methods: Among the general physical check-up population, subjects with shallow anterior chambers, as judged by van Herick technique, were recruited for further investigation. Ultrasound biomicroscope (UBM) was used to detect and measure the cysts located in the iris and/or ciliary body, the anterior chamber depth (ACD), the angle opening distance at 500 μm (AOD500), and the trabecular-iris angle (TIA). A-scan ultrasonography was used to measure the ocular biometry, including lens thickness, axial length, lens/axial length factor (LAF), and relative lens position (RLP). The effect of the cyst on narrowing the corresponding anterior chamber angle and the entire angle was evaluated by the UBM images, ocular biometry, and gonioscopic grading. The eye with unilateral cyst was compared with the eye without the cyst for further analysis. Results: Among the 727 subjects with shallow anterior chamber, primary iris and ciliary body cysts were detected in 250 (34.4%) patients; among them 96 (38.4%) patients showed unilateral single cyst, 21 (8.4%) patients had unilateral double cysts, and 42 (16.8%) patients manifested unilateral multiple and multi-quadrants cysts. Plateau iris configuration was found in 140 of 361 (38.8%) eyes with cysts. The mean size of total cysts was (0.6547±0.2319) mm. In evaluation of the effect of the cyst size and location on narrowing the corresponding angle to their position, the proportion of the cysts causing corresponding angle narrowing or closure among the cysts larger than 0.8 mm (113/121, 93.4%) was found to be significantly higher than that of the cysts smaller than 0.8 mm (373/801, 46.6%), and a significant higher proportion was also found in the cysts located at iridociliary sulcus (354/437, 81.0%) than in that at the pars plicata (131/484, 27.1%). In evaluating the effect of the cyst on the entire anterior chamber angle, the eyes with multiple and multi-quadrants cysts manifested significant narrowing of the entire anterior chamber angle as compared with the eyes without cysts, based on the data analysis in comparison of TIA, AOD500, and gonioscopic grading evaluation. The unilateral single or double cysts in the eyes had no significant effect on narrowing of anterior chamber angle as compared with eyes without cysts. The iris and/or ciliary body cysts did not seem to affect the axial length, ACD, lens thickness, RLP, LAF. Conclusions: The prevalence of primary iris and ciliary body cyst was 34.4% in the subjects with shallow anterior chamber. The cysts larger than 0.8 mm, locating at iridociliary sulcus, or multiple and extensive cysts were inclined to cause the angle narrowing or closure. PMID:22949363

  1. Accommodation and age-dependent eye model based on in vivo measurements.

    PubMed

    Zapata-Díaz, Juan F; Radhakrishnan, Hema; Charman, W Neil; López-Gil, Norberto

    2018-03-21

    To develop a flexible model of the average eye that incorporates changes with age and accommodation in all optical parameters, including entrance pupil diameter, under photopic, natural, environmental conditions. We collated retrospective in vivo measurements of all optical parameters, including entrance pupil diameter. Ray-tracing was used to calculate the wavefront aberrations of the eye model as a function of age, stimulus vergence and pupil diameter. These aberrations were used to calculate objective refraction using paraxial curvature matching. This was also done for several stimulus positions to calculate the accommodation response/stimulus curve. The model predicts a hyperopic change in distance refraction as the eye ages (+0.22D every 10 years) between 20 and 65 years. The slope of the accommodation response/stimulus curve was 0.72 for a 25 years-old subject, with little change between 20 and 45 years. A trend to a more negative value of primary spherical aberration as the eye accommodates is predicted for all ages (20-50 years). When accommodation is relaxed, a slight increase in primary spherical aberration (0.008μm every 10 years) between 20 and 65 years is predicted, for an age-dependent entrance pupil diameter ranging between 3.58mm (20 years) and 3.05mm (65 years). Results match reasonably well with studies performed in real eyes, except that spherical aberration is systematically slightly negative as compared with the practical data. The proposed eye model is able to predict changes in objective refraction and accommodation response. It has the potential to be a useful design and testing tool for devices (e.g. intraocular lenses or contact lenses) designed to correct the eye's optical errors. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  2. Location, Location, Location: Eye-Tracking Evidence that Consumers Preferentially View Prominently Positioned Nutrition Information

    PubMed Central

    Graham, Dan J.; Jeffery, Robert W.

    2012-01-01

    Background Nutrition Facts labels can keep consumers better informed about their diets' nutritional composition, however, consumers currently do not understand these labels well or use them often. Thus, modifying existing labels may benefit public health. Objective The present study tracked the visual attention of individuals making simulated food-purchasing decisions to assess Nutrition Facts label viewing. Primary research questions were how self-reported viewing of Nutrition Facts labels and their components relates to measured viewing and whether locations of labels and specific label components relate to viewing. Design The study involved a simulated grocery shopping exercise conducted on a computer equipped with an eye-tracking camera. A post-task survey assessed self-reported nutrition information viewing, health behaviors, and demographics. Subjects/setting Individuals 18 years old and older and capable of reading English words on a computer (n=203) completed the 1-hour protocol at the University of Minnesota during Spring 2010. Statistical analyses Primary analyses included χ2, analysis of variance, and t tests comparing self-reported and measured viewing of label components in different presentation configurations. Results Self-reported viewing of Nutrition Facts label components was higher than objectively measured viewing. Label components at the top of the label were viewed more than those at the bottom, and labels positioned in the center of the screen were viewed more than those located on the sides. Conclusions Nutrition Facts label position within a viewing area and position of specific components on a label relate to viewing. Eye tracking is a valuable technology for evaluating consumers' attention to nutrition information, informing nutrition labeling policy (eg, front-of-pack labels), and designing labels that best support healthy dietary decisions. PMID:22027053

  3. Evidence for integrating eye health into primary health care in Africa: a health systems strengthening approach

    PubMed Central

    2013-01-01

    Background The impact of unmet eye care needs in sub-Saharan Africa is compounded by barriers to accessing eye care, limited engagement with communities, a shortage of appropriately skilled health personnel, and inadequate support from health systems. The renewed focus on primary health care has led to support for greater integration of eye health into national health systems. The aim of this paper is to demonstrate available evidence of integration of eye health into primary health care in sub-Saharan Africa from a health systems strengthening perspective. Methods A scoping review method was used to gather and assess information from published literature, reviews, WHO policy documents and examples of eye and health care interventions in sub-Saharan Africa. Findings were compiled using a health systems strengthening framework. Results Limited information is available about eye health from a health systems strengthening approach. Particular components of the health systems framework lacking evidence are service delivery, equipment and supplies, financing, leadership and governance. There is some information to support interventions to strengthen human resources at all levels, partnerships and community participation; but little evidence showing their successful application to improve quality of care and access to comprehensive eye health services at the primary health level, and referral to other levels for specialist eye care. Conclusion Evidence of integration of eye health into primary health care is currently weak, particularly when applying a health systems framework. A realignment of eye health in the primary health care agenda will require context specific planning and a holistic approach, with careful attention to each of the health system components and to the public health system as a whole. Documentation and evaluation of existing projects are required, as are pilot projects of systematic approaches to interventions and application of best practices. Multi-national research may provide guidance about how to scale up eye health interventions that are integrated into primary health systems. PMID:23506686

  4. Dysthyroid Orbitopathy Presenting with Gaze-Evoked Amaurosis: Case Report and Review of the Literature.

    PubMed

    Orlans, Harry O; Bremner, Fion D

    2015-01-01

    Gaze-evoked amaurosis (GEA) describes visual loss associated with eccentric gaze that recovers when the eye is returned to primary position. Here we describe an unusual case of bilateral GEA as the presenting feature of dysthyroid orbitopathy. This is only the third such case to be reported in the literature and the first to feature bilateral GEA in all positions of gaze without accompanying proptosis or ophthalmoplegia. A 50-year-old man who had recently commenced treatment for thyrotoxicosis presented with a 3-week history of typical GEA in both eyes in all positions of gaze. He subsequently developed a bilateral compressive optic neuropathy which was only partially responsive to high dose steroid therapy. Although an uncommon presenting feature of dysthyroid orbitopathy, GEA is an ominous symptom that may precede sight-threatening optic nerve compromise. When present, early immunosuppressive and/or decompressive treatment should be considered.

  5. A case of oculo-cerebral B-cell lymphoma in a cat.

    PubMed

    Giordano, Cristina; Giudice, Chiara; Bellino, Claudio; Borrelli, Antonio; D'Angelo, Antonio; Gianella, Paola

    2013-01-01

    To describe a case of a cat with primary B-cell lymphoma affecting the eye and brain and which shared features similar to oculo-cerebral lymphoma in humans. A 13-year-old castrated male Persian cat presented with clinical signs of anterior uveitis and increased intraocular pressure (IOP) in the left eye (OS). A complete diagnostic work-up was declined, and left-eye enucleation was performed. The globe was submitted for histopathology. One week after surgery, the cat became inappetent, hypothermic, and aggressive. Euthanasia was requested by the owner, and a necropsy was permitted.   Histopathology of the enucleated globe revealed an extensive neoplastic infiltration consistent with large-cell lymphoma, affecting the anterior uvea, neuroretina and optic nerve. At necropsy, all organs were unremarkable except for the brain, where there was a neoplastic cell population consistent with that described in the left eye, infiltrated and expanded meninges, and perivascular spaces. Immunohistochemically, the neoplastic cells were positive for B-cell marker (CD20) and negative for T-cell marker (CD3). Histology and immunophenotyping suggested a diagnosis of primary central nervous system and ocular large B-cell lymphoma. The lymphoma in this cat resembled oculo-cerebral lymphoma in humans, sharing similar clinical features and histopathological findings, including the perivascular pattern of neoplastic cell infiltration. To the best of the authors' knowledge, this is the first description of a primary oculo-cerebral B-cell lymphoma in a cat. © 2012 American College of Veterinary Ophthalmologists.

  6. Fundus autofluorescence patterns in primary intraocular lymphoma.

    PubMed

    Casady, Megan; Faia, Lisa; Nazemzadeh, Maryam; Nussenblatt, Robert; Chan, Chi-Chao; Sen, H Nida

    2014-02-01

    To evaluate fundus autofluorescence (FAF) patterns in patients with primary intraocular (vitreoretinal) lymphoma. Records of all patients with primary intraocular lymphoma who underwent FAF imaging at the National Eye Institute were reviewed. Fundus autofluorescence patterns were evaluated with respect to clinical disease status and the findings on fluorescein angiography and spectral-domain optical coherence tomography. There were 18 eyes (10 patients) with primary intraocular lymphoma that underwent FAF imaging. Abnormal autofluorescence in the form of granular hyperautofluorescence and hypoautofluorescence was seen in 11 eyes (61%), and blockage by mass lesion was seen in 2 eyes (11%). All eyes with granular pattern on FAF had active primary intraocular lymphoma at the time of imaging, but there were 5 eyes with unremarkable FAF, which were found to have active lymphoma. The most common pattern on fluorescein angiography was hypofluorescent round spots with a "leopard spot" appearance (43%). These hypofluorescent spots on fluorescein angiography correlated with hyperautofluorescent spots on FAF in 5 eyes (36%) (inversion of FAF). Nodular hyperreflective spots at the level of retinal pigment epithelium on optical coherence tomography were noted in 43% of eyes. The hyperautofluorescent spots on FAF correlated with nodular hyperreflective spots on optical coherence tomography in 6 eyes (43%). Granularity on FAF was associated with active lymphoma in majority of the cases. An inversion of FAF (hyperautofluorescent spots on FAF corresponding to hypofluorescent spots on fluorescein angiography) was observed in less than half of the eyes.

  7. Primary Conjunctival Tuberculosis Presenting as Dry Eye: A Rare Case Report and Review of the Literature.

    PubMed

    Brar, Rupinder Kaur; Singh, Ashok; Deshpande, Archana Hemant; Gargade, Chitrawati Bal; Das, Sujit

    2017-11-01

    Primary conjunctival tuberculosis is very rare in the developed countries. In an endemic country like India, it should be considered in the differential diagnosis of any unusual conjunctival lesion with unilaterality, chronicity, and nonresolution of symptoms after steroid use. We present the case of a 52-year-old female who presented with unilateral itching and blurring of vision for 20 days. There were irregular nodular elevated areas with shrinkage of the lower palpebral conjunctiva. A biopsy of the lesion revealed necrotizing epithelioid cell granulomas along with Langhans type of giant cells. However, no acid-fast bacilli were seen on Ziehl-Neelsen stain. Systemic examination of the patient was normal, and there was no evidence of pulmonary tuberculosis. Polymerase chain reaction of conjunctival scrapings was positive for Mycobacterium tuberculosis . The patient was started on antitubercular drugs. We present this very rare case of primary tuberculosis of the conjunctiva presenting with dryness of the eye.

  8. A variant of WEBINO syndrome after top of the basilar artery stroke.

    PubMed

    Sierra-Hidalgo, Fernando; Moreno-Ramos, Teresa; Villarejo, Alberto; Martín-Gil, Leticia; de Pablo-Fernández, Eduardo; Correas-Callero, Elisa; Ramos, Ana; Benito-León, Julián

    2010-11-01

    Wall-eyed bilateral internuclear ophthalmoplegia (WEBINO) is an uncommon neuro-ophthalmologic syndrome consisting of both eyes primary position exotropia and bilateral internuclear ophthalmoplegia. It is thought to be caused by medial midbrain lesions involving both bilateral medial longitudinal fasciculi and medial rectus subnuclei. We report the clinical and neuroimaging findings of a WEBINO syndrome associated to bilateral ptosis, non-reactive mydriasis and complete vertical gaze palsy in a 55-year-old man who suffered a top of the basilar artery stroke causing tegmental midbrain infarction. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Glaucoma-service provision in Scotland: introduction and need for Scottish Intercollegiate Guidelines Network guidelines.

    PubMed

    Syrogiannis, Andreas; Rotchford, Alan P; Agarwal, Pankaj Kumar; Kumarasamy, Manjula; Montgomery, Donald; Burr, Jennifer; Sanders, Roshini

    2015-01-01

    To describe the pattern of glaucoma-service delivery in Scotland and identify areas for improvement, taking into account Scottish General Ophthalmic Services (GOS) arrangements and the Eye Care Integration project, and to design Scottish Intercollegiate Guidelines Network (SIGN) guidelines to refine the primary and secondary interface of glaucoma care. A glaucoma-survey questionnaire was sent to all consultant glaucomatologists in Scotland. The design of SIGN guidelines was based on the results of the questionnaire using SIGN methodology. Over 90% of Scottish glaucoma care is triaged and delivered within hospital services. Despite GOS referral, information is variable. There are no consistent discharge practices to the community. These results led to defined research questions that were answered, thus formulating the content of the SIGN guidelines. The guideline covers the assessment of patients in primary care, referral criteria to hospital, discharge criteria from hospital to community, and monitoring of patients at risk of glaucoma. With increasing age and limitations to hospital resources, refining glaucoma pathways between primary and secondary care has become a necessity. Scotland has unique eye care arrangements with both the GOS and Eye Care Integration project. It is hoped that implementation of SIGN guidelines will identify glaucoma at the earliest opportunity and reduce the rate of false-positive referrals to hospital.

  10. Qualitative Assessment of Ultrasound Biomicroscopic Images Using Standard Photographs: The Liwan Eye Study

    PubMed Central

    Jiang, Yuzhen; Huang, Wenyong; Huang, Qunxiao; Zhang, Jian; Foster, Paul J.

    2010-01-01

    Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes. PMID:19834039

  11. Familial exudative vitreoretinopathy mimicking persistent hyperplastic primary vitreous.

    PubMed

    Chang-Godinich, A; Paysse, E A; Coats, D K; Holz, E R

    1999-04-01

    To report an unusual case of familial exudative vitreoretinopathy in an infant. Case report. A 6-day-old girl had unilateral microphthalmia in the right eye, with a retrolental plaque initially diagnosed as persistent hyperplastic primary vitreous. Three months later, peripheral retinal vascular changes and a fibrovascular ridge were noted in the left eye, suggesting familial exudative vitreoretinopathy as the cause in both eyes. The microphthalmic right eye was unsalvageable. The left eye developed an exudative retinal detachment despite photocoagulation of the peripheral avascular retina. Additional cryotherapy resulted in resolution of the detachment and regression of the vascular changes. With highly asymmetric involvement, neonatal familial exudative vitreoretinopathy can mimic persistent hyperplastic primary vitreous. Fellow eye involvement can progress rapidly.

  12. Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.

    PubMed

    Singh, G; Singh Bhinder, H

    To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.3614.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirm e r-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in losed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.770.37 C in closed eye position and 35.020.39 C in open eye position as compared to 27.912.46 C in closed eye position and 28.012.46 C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.250.90 C in infrared thermometry and 0.100.00 C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared therm o m e t ry recorded 35.080.61 C temperature in closed eye position and 35.530.63 C in open eye position as compared to 27.412.48 C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.450.14 C (p<0.0000) with infrared thermometry as compared to no change 0.000.00 C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.

  13. Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.

    PubMed

    Singh, G; Bhinder, H Singh

    2005-01-01

    To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.36+/-14.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirmer-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in closed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.77+/-0.37 degrees C in closed eye position and 35.02+/-0.39 degrees C in open eye position as compared to 27.91+/-2.46 degrees C in closed eye position and 28.01+/-2.46 degrees C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.25+/-0.90 degrees C in infrared thermometry and 0.10+/-0.00 degrees C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared thermometry recorded 35.08+/-0.61 degrees C temperature in closed eye position and 35.53+/-0.63 degrees C in open eye position as compared to 27.41+/-2.48 degrees C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.45+/-0.14 degrees C (p<0.0000) with infrared thermometry as compared to no change 0.00+/-0.00 degrees C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.

  14. Role of muscle pulleys in producing eye position-dependence in the angular vestibuloocular reflex: a model-based study

    NASA Technical Reports Server (NTRS)

    Thurtell, M. J.; Kunin, M.; Raphan, T.; Wall, C. C. (Principal Investigator)

    2000-01-01

    It is well established that the head and eye velocity axes do not always align during compensatory vestibular slow phases. It has been shown that the eye velocity axis systematically tilts away from the head velocity axis in a manner that is dependent on eye-in-head position. The mechanisms responsible for producing these axis tilts are unclear. In this model-based study, we aimed to determine whether muscle pulleys could be involved in bringing about these phenomena. The model presented incorporates semicircular canals, central vestibular pathways, and an ocular motor plant with pulleys. The pulleys were modeled so that they brought about a rotation of the torque axes of the extraocular muscles that was a fraction of the angle of eye deviation from primary position. The degree to which the pulleys rotated the torque axes was altered by means of a pulley coefficient. Model input was head velocity and initial eye position data from passive and active yaw head impulses with fixation at 0 degrees, 20 degrees up and 20 degrees down, obtained from a previous experiment. The optimal pulley coefficient required to fit the data was determined by calculating the mean square error between data and model predictions of torsional eye velocity. For active head impulses, the optimal pulley coefficient varied considerably between subjects. The median optimal pulley coefficient was found to be 0.5, the pulley coefficient required for producing saccades that perfectly obey Listing's law when using a two-dimensional saccadic pulse signal. The model predicted the direction of the axis tilts observed in response to passive head impulses from 50 ms after onset. During passive head impulses, the median optimal pulley coefficient was found to be 0.21, when roll gain was fixed at 0.7. The model did not accurately predict the alignment of the eye and head velocity axes that was observed early in the response to passive head impulses. We found that this alignment could be well predicted if the roll gain of the angular vestibuloocular reflex was modified during the initial period of the response, while pulley coefficient was maintained at 0.5. Hence a roll gain modification allows stabilization of the retinal image without requiring a change in the pulley effect. Our results therefore indicate that the eye position-dependent velocity axis tilts could arise due to the effects of the pulleys and that a roll gain modification in the central vestibular structures may be responsible for countering the pulley effect.

  15. The subtlety of simple eyes: the tuning of visual fields to perceptual challenges in birds

    PubMed Central

    Martin, Graham R.

    2014-01-01

    Birds show interspecific variation both in the size of the fields of individual eyes and in the ways that these fields are brought together to produce the total visual field. Variation is found in the dimensions of all main parameters: binocular region, cyclopean field and blind areas. There is a phylogenetic signal with respect to maximum width of the binocular field in that passerine species have significantly broader field widths than non-passerines; broadest fields are found among crows (Corvidae). Among non-passerines, visual fields show considerable variation within families and even within some genera. It is argued that (i) the main drivers of differences in visual fields are associated with perceptual challenges that arise through different modes of foraging, and (ii) the primary function of binocularity in birds lies in the control of bill position rather than in the control of locomotion. The informational function of binocular vision does not lie in binocularity per se (two eyes receiving slightly different information simultaneously about the same objects from which higher-order depth information is extracted), but in the contralateral projection of the visual field of each eye. Contralateral projection ensures that each eye receives information from a symmetrically expanding optic flow-field from which direction of travel and time to contact targets can be extracted, particularly with respect to the control of bill position. PMID:24395967

  16. Prevalence of Undiagnosed Age-Related Macular Degeneration in Primary Eye Care.

    PubMed

    Neely, David C; Bray, Kevin J; Huisingh, Carrie E; Clark, Mark E; McGwin, Gerald; Owsley, Cynthia

    2017-06-01

    Age-related macular degeneration (AMD) is the leading cause of irreversible vision impairment in older adults in the United States, yet little is known about whether AMD is appropriately diagnosed in primary eye care. To examine the prevalence of eyes with AMD in patients seen in primary eye care clinics who purportedly have normal macular health per their medical record and the association of AMD with patient and physician characteristics. In this cross-sectional study of primary eye care practices in Birmingham, Alabama, 644 persons 60 years or older with normal macular health per medical record based on their most recent dilated comprehensive eye examination by a primary eye care ophthalmologist or optometrist were enrolled from May 1, 2009, through December 31, 2011. Data analysis was performed from May 1, 2016, through December 20, 2016. Presence of AMD as defined by the Clinical Age-Related Maculopathy Staging system based on color fundus photography and a masked grader. Types of AMD-associated lesions were noted. Patient health and physician characteristics were collected. The sample consisted of 1288 eyes from 644 participants (231 [35.9%] male and 413 [64.1%] female; mean [SD] age, 69.4 [6.1] years; 611 white [94.9%]) seen by 31 primary eye care ophthalmologists or optometrists. A total of 968 eyes (75.2%) had no AMD, in agreement with their medical record; 320 (24.8%) had AMD despite no diagnosis of AMD in the medical record. Among eyes with undiagnosed AMD, 32 (10.0%) had hyperpigmentation, 43 (13.4%) had hypopigmentation, 249 (77.8%) had small drusen, 250 (78.1%) had intermediate drusen, and 96 (30.0%) had large drusen. Undiagnosed AMD was associated with older patient age (odds ratio [OR], 1.06; 95% CI, 1.04-1.09; P < .001), male sex (age-adjusted OR, 1.39; 95% CI, 1.02-1.91; P = .04), and less than a high school education (age-adjusted OR, 2.40; 95% CI, 1.03-5.62; P = .04). Prevalence of undiagnosed AMD was not different for ophthalmologists and optometrists (age adjusted OR, 0.99; 95% CI, 0.71-1.36; P = .94). Approximately 25.0% of eyes deemed to be normal based on dilated eye examination by primary eye care physicians had macular characteristics that indicated AMD revealed by fundus photography and trained raters. A total of 30.0% of eyes with undiagnosed AMD had AMD with large drusen that would have been treatable with nutritional supplements had it been diagnosed. Improved AMD detection strategies may be needed in primary eye care as more effective treatment strategies for early AMD become available in the coming years.

  17. Topical brinzolamide (Azopt) versus placebo in the treatment of infantile nystagmus syndrome (INS).

    PubMed

    Hertle, Richard W; Yang, Dongsheng; Adkinson, Tonia; Reed, Michael

    2015-04-01

    To test the hypothesis that the topical carbonic anhydrase inhibitor brinzolamide (Azopt) has beneficial effects versus placebo on measures of nystagmus and visual acuity in adult subjects with infantile nystagmus syndrome (INS). Prospective, cross-over, double masked clinical trial. Single centre. Five subjects ≥18 years old with typical INS and best-binocular visual acuity in their primary position null zone ETDRS 55 letters to 85 letters (20/200 to 20/50) and had no previous treatment for nystagmus. In a randomised order, each subject received one drop of Azopt or placebo in both eyes three times a day separated by a washout period of at least a week followed by Azopt or placebo in both eyes three times a day; thus each subject got the drug and placebo, each acting as his or her own control. The nystagmus acuity function and INS waveforms obtained from eye movement recordings, binocular optotype visual acuity, using the ETDRS protocol analysed individually and as a group before and after Azopt and placebo. Versus placebo and baseline measures, topical Azopt significantly improved; INS waveform characteristics in the primary position null zone, group mean values of the nystagmus acuity function across gaze (p<0.01) and group mean ETDRS binocular letter visual acuity (p<0.05). There was a predictable decrease in intraocular pressure (IOP) without any systemic or ocular adverse events. Although a prospective large-scale clinical trial is needed to prove effectiveness, an eye-drop-based therapy for INS may emerge as a viable addition to optical, surgical, behavioural and systemic drug therapies for INS. NCT01312402. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. NATIONAL PREPAREDNESS: Technologies to Secure Federal Buildings

    DTIC Science & Technology

    2002-04-25

    Medium, some resistance based on sensitivity of eye Facial recognition Facial features are captured and compared Dependent on lighting, positioning...two primary types of facial recognition technology used to create templates: 1. Local feature analysis—Dozens of images from regions of the face are...an adjacent feature. Attachment I—Access Control Technologies: Biometrics Facial Recognition How the technology works

  19. Primary central nervous system lymphoma in an human immunodeficiency virus-infected patient mimicking bilateral eye sign in brain seen in fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography.

    PubMed

    Kamaleshwaran, Koramadai Karuppusany; Thirugnanam, Rajasekar; Shibu, Deepu; Kalarikal, Radhakrishnan Edathurthy; Shinto, Ajit Sugunan

    2014-04-01

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG PET/CT) has proven useful in the diagnosis, staging, and detection of metastasis and posttreatment monitoring of several malignancies in human immunodeficiency virus (HIV)-infected patients. It also has the ability to make the important distinction between malignancy and infection in the evaluation of central nervous system (CNS) lesions, leading to the initiation of the appropriate treatment and precluding the need for invasive biopsy. We report an interesting case of HIV positive 35-year-old woman presented with headache, disorientation, and decreased level of consciousness. She underwent whole body PET/CT which showed multiple lesions in the cerebrum which mimics bilateral eye in brain. A diagnosis of a primary CNS lymphoma was made and patient was started on chemotherapy.

  20. Apoptosis of conjunctival epithelial cells before and after the application of autologous serum eye drops in severe dry eye disease.

    PubMed

    Rybickova, Ivana; Vesela, Viera; Fales, Ivan; Skalicka, Pavlina; Jirsova, Katerina

    2016-06-01

    To assess the impact of autologous serum eye drops on the level of ocular surface apoptosis in patients with bilateral severe dry eye disease. This prospective study was conducted on 10 patients with severe dry eye due to graft versus host disease (group 1) and 6 patients with severe dry eye due to primary Sjögren's syndrome (group 2). Impression cytology specimens from the bulbar conjunctiva were obtained before and after a three-month treatment with 20% autologous serum eye drops applied a maximum of 12 times a day together with regular therapy with artificial tears. The percentage of apoptotic epithelial cells was evaluated immunochemically using anti-active caspase 3 antibody. In group 1, the mean percentage of apoptotic cells was 3.6% before the treatment. The three-month treatment led to a significant decrease to a mean percentage of 1.8% (P = 0.028). The mean percentage of apoptotic conjunctival cells decreased from 5.4% before the treatment to 3.8% in group 2; however, these results did not reach the level of significance. Three-month autologous serum treatment led to the improvement of ocular surface apoptosis, especially in the group of patients with severe dry eye due to graft versus host disease. This result supports the very positive effect of autologous serum on the ocular surface in patients suffering from severe dry eye.

  1. Biometric parameters in different stages of primary angle closure using low-coherence interferometry.

    PubMed

    Yazdani, Shahin; Akbarian, Shadi; Pakravan, Mohammad; Doozandeh, Azadeh; Afrouzifar, Mohsen

    2015-03-01

    To compare ocular biometric parameters using low-coherence interferometry among siblings affected with different degrees of primary angle closure (PAC). In this cross-sectional comparative study, a total of 170 eyes of 86 siblings from 47 families underwent low-coherence interferometry (LenStar 900; Haag-Streit, Koeniz, Switzerland) to determine central corneal thickness, anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), vitreous depth, and axial length (AL). Regression coefficients were applied to show the trend of the measured variables in different stages of angle closure. To evaluate the discriminative power of the parameters, receiver operating characteristic curves were used. Best cutoff points were selected based on the Youden index. Sensitivity, specificity, positive and negative predicative values, positive and negative likelihood ratios, and diagnostic accuracy were determined for each variable. All biometric parameters changed significantly from normal eyes to PAC suspects, PAC, and PAC glaucoma; there was a significant stepwise decrease in central corneal thickness, ACD, AD, vitreous depth, and AL, and an increase in LT and LT/AL. Anterior chamber depth and AD had the best diagnostic power for detecting angle closure; best levels of sensitivity and specificity were obtained with cutoff values of 3.11 mm for ACD and 2.57 mm for AD. Biometric parameters measured by low-coherence interferometry demonstrated a significant and stepwise change among eyes affected with various degrees of angle closure. Although the current classification scheme for angle closure is based on anatomical features, it has excellent correlation with biometric parameters.

  2. Adaptive eye-gaze tracking using neural-network-based user profiles to assist people with motor disability.

    PubMed

    Sesin, Anaelis; Adjouadi, Malek; Cabrerizo, Mercedes; Ayala, Melvin; Barreto, Armando

    2008-01-01

    This study developed an adaptive real-time human-computer interface (HCI) that serves as an assistive technology tool for people with severe motor disability. The proposed HCI design uses eye gaze as the primary computer input device. Controlling the mouse cursor with raw eye coordinates results in sporadic motion of the pointer because of the saccadic nature of the eye. Even though eye movements are subtle and completely imperceptible under normal circumstances, they considerably affect the accuracy of an eye-gaze-based HCI. The proposed HCI system is novel because it adapts to each specific user's different and potentially changing jitter characteristics through the configuration and training of an artificial neural network (ANN) that is structured to minimize the mouse jitter. This task is based on feeding the ANN a user's initially recorded eye-gaze behavior through a short training session. The ANN finds the relationship between the gaze coordinates and the mouse cursor position based on the multilayer perceptron model. An embedded graphical interface is used during the training session to generate user profiles that make up these unique ANN configurations. The results with 12 subjects in test 1, which involved following a moving target, showed an average jitter reduction of 35%; the results with 9 subjects in test 2, which involved following the contour of a square object, showed an average jitter reduction of 53%. For both results, the outcomes led to trajectories that were significantly smoother and apt at reaching fixed or moving targets with relative ease and within a 5% error margin or deviation from desired trajectories. The positive effects of such jitter reduction are presented graphically for visual appreciation.

  3. Impact of lifestyle intervention on dry eye disease in office workers: a randomized controlled trial.

    PubMed

    Kawashima, Motoko; Sano, Kokoro; Takechi, Sayuri; Tsubota, Kazuo

    2018-04-04

    To evaluate the effects of a 2-month lifestyle intervention for dry eye disease in office workers. Prospective interventional study (randomized controlled study). Forty-one middle-aged Japanese office workers (men, 22; women, 19; 39.2 ± 8.0 years) with definite and probable dry eye disease were enrolled and randomized to an intervention group (n = 22) and a control group (n = 19). The intervention aimed at modifying diet, increasing physical activity, and encouraging positive thinking. The primary outcome was change in dry eye disease diagnoses. Secondary outcome was change in disease parameters, including dry eye symptoms, as assessed using the Dry Eye-Related Quality of Life Score, corneal and conjunctival staining scores, tear break-up time, and Schirmer test results. A total of 36 participants (intervention group, 17; control group, 19) completed the study. The number of definite dry eye disease diagnoses decreased from four to none (p =.05), and the dry eye symptom score showed a significant decrease in the intervention group (p =.03). In contrast, the corneal and conjunctival staining scores, tear break-up time, and Schirmer test results did not differ significantly between groups. The 2-month lifestyle intervention employed in this study improved dry eye disease status among office workers, with a considerable decrease in subjective symptoms. Lifestyle intervention may be a promising management option for dry eye disease, although further investigation of long-term effects are required.

  4. A prospective clinical evaluation of augmented Anderson procedure for idiopathic infantile nystagmus.

    PubMed

    Gupta, Ritesh; Sharma, Pradeep; Menon, Vimala

    2006-08-01

    To evaluate the efficacy of the augmented Anderson procedure in idiopathic infantile nystagmus (IIN). Twelve consecutive patients older than 5 years having IIN with eccentric null position and anomalous head position were enrolled in an institution-based study. Best-corrected visual acuity (uniocular and binocular and in both null position and primary position), slit-lamp examination, fundus examination, ocular motility examination, and stereopsis using TNO were recorded. In all cases the augmented Anderson procedure, that is, recession of the yoke muscles (9-mm medial rectus and 12-mm lateral rectus), was performed. Eye movements were recorded before and 3 months after surgery in the primary position, right gaze 15 and 30 degrees, and left gaze 15 and 30 degrees. All patients had improvement in their anomalous head posture after surgery (p = 0.0001). The nystagmus intensity in the primary position decreased from 22.0 +/- 15.9 degrees cycles/s preoperatively to 10.6 +/- 10.2 degrees cycles/s at 3 months postoperatively. The change was statistically significant (p = 0.006). After surgery, binocular visual acuity using the Early Treatment Diabetic Retinopathy Study chart improved in primary position (p = 0.007). No patient developed more than mild limitation of horizontal movements after surgery. The augmented Anderson procedure is successful in correcting face turn in patients having IIN with eccentric null position, resulting in an increase in visual acuity and a decrease in nystagmus intensity in primary position. Further studies with a longer follow-up are required to assess the long-term efficacy of this procedure.

  5. Automated facial recognition and candidate list rank change of computer generated facial approximations generated with multiple eye orb positions.

    PubMed

    Parks, Connie L; Monson, Keith L

    2016-09-01

    Expanding on research previously reported by the authors, this study further examines the recognizability of ReFace facial approximations generated with the following eye orb positions: (i) centrally within the bony eye socket, (ii) 1.0mm superior and 2.0mm lateral relative to center, and (iii) 1.0mm superior and 2.5mm lateral relative to center. Overall, 81% of the test subjects' approximation ranks improved with the use of either of the two supero-lateral eye orbs. Highly significant performance differences (p<0.01) were observed between the approximations with centrally positioned eye orbs (i) and approximations with the eye orbs placed in the supero-laterally positions (ii and iii). Noteworthy was the observation that in all cases when the best rank for an approximation was obtained with the eye orbs in position (iii), the second best rank was achieved with the eye orbs in position (ii). A similar pattern was also observed when the best rank was obtained with the eye orbs in position (ii), with 60% of the second best ranks observed in position (iii). It is argued, therefore, that an approximation constructed with the eye orbs placed in either of the two supero-lateral positions may be more effective and operationally informative than centrally positioned orbs. Copyright © 2016. Published by Elsevier Ireland Ltd.

  6. Role of the water-drinking test in medically treated primary open angle glaucoma patients.

    PubMed

    Salcedo, H; Arciniega, D; Mayorga, M; Wu, L

    2018-05-01

    The water-drinking test (WDT) has recently re-emerged as a possible way to determine the competency of the trabecular meshwork. We performed a prospective interventional study to test the hypothesis that the WDT could be useful in assessing fluctuations in patients undergoing treatment for primary open angle glaucoma (POAG). We included 122 patients; 62 on medical treatment for POAG (n=123 eyes) and 60 controls (n=120 eyes). The study group had been on intraocular pressures (IOP) lowering treatment continuously for at least 3months with stable IOP. The WDT was performed during fasting and was considered positive if it fluctuated ≥6mmHg. The patients on medical treatment had a mean age of 50.56±18.45 years vs. 51.35±11.22 for the controls (P=0.34); with 71% being female in the study group and 77% in the control group. In the study group; 52% were on beta blockers (n=64), 27% combination of two or more medications (n=33), 19% prostaglandin analogues (n=24) and 2% alpha agonists (n=2). The WDT was positive in 17.07% (n=21) in the study group and 2.5% (n=3) in the control group (P=0.0001). The mean fluctuation was 7.14±2.15mmHg in the study group and 6.00±0mmHg in the controls (P=0.33). A positive WDT was found in 33.33% (n=11) of those on combination therapy; 12.5% (n=3) prostaglandin analogues and 10.94% (n=7) beta blockers (P=0.03). Combination therapy had the highest positive WDT fluctuation (7.54±2.87) followed by prostaglandin analogues (7.00±1.00) and beta blockers (6.57±0.78) with a P value of 0.44. The WDT can identify significant fluctuations in eyes with POAG that are medically treated. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  7. Anatomical manifestations of primary blast ocular trauma observed in a postmortem porcine model.

    PubMed

    Sherwood, Daniel; Sponsel, William E; Lund, Brian J; Gray, Walt; Watson, Richard; Groth, Sylvia L; Thoe, Kimberly; Glickman, Randolph D; Reilly, Matthew A

    2014-02-24

    We qualitatively describe the anatomic features of primary blast ocular injury observed using a postmortem porcine eye model. Porcine eyes were exposed to various levels of blast energy to determine the optimal conditions for future testing. We studied 53 enucleated porcine eyes: 13 controls and 40 exposed to a range of primary blast energy levels. Eyes were preassessed with B-scan and ultrasound biomicroscopy (UBM) ultrasonography, photographed, mounted in gelatin within acrylic orbits, and monitored with high-speed videography during blast-tube impulse exposure. Postimpact photography, ultrasonography, and histopathology were performed, and ocular damage was assessed. Evidence for primary blast injury was obtained. While some of the same damage was observed in the control eyes, the incidence and severity of this damage in exposed eyes increased with impulse and peak pressure, suggesting that primary blast exacerbated these injuries. Common findings included angle recession, internal scleral delamination, cyclodialysis, peripheral chorioretinal detachments, and radial peripapillary retinal detachments. No full-thickness openings of the eyewall were observed in any of the eyes tested. Scleral damage demonstrated the strongest associative tendency for increasing likelihood of injury with increased overpressure. These data provide evidence that primary blast alone (in the absence of particle impact) can produce clinically relevant ocular damage in a postmortem model. The blast parameters derived from this study are being used currently in an in vivo model. We also propose a new Cumulative Injury Score indicating the clinical relevance of observed injuries.

  8. Infantile aperiodic alternating nystagmus.

    PubMed

    Hertle, Richard W; Reznick, Leah; Yang, Dongsheng

    2009-01-01

    This study identifies the clinical and ocular motility characteristics of the periodic and aperiodic forms of infantile alternating nystagmus (IAPAN) and establishes the range of electrophysiological and clinical characteristics while providing clues to its presence and pathophysiology. Seventy-eight patients with ocular oscillations consistent with IAPAN were reported. Outcome variables were: age, follow-up in months, vision, strabismus, other eye and systemic abnormalities, head position, periodicity, cycle and null period duration, foveation time, waveforms, and cycle symmetry. Age range was 1 to 67 years, 50% had pure periodic and aperiodic forms, 46% had albinism, 26% had binocular acuity of 20/40 or greater, 72% had strabismus, 35% had amblyopia, 31% had other eye disease, 14% had systemic disease, 87% had an anomalous head posture, and 65% had binocular directional asymmetry. The periodic cycle averaged 224 seconds and the aperiodic cycle ranged from 2 to more than 300 seconds. One in three patients with strabismus and nystagmus periodicity had a static head posture. Fifteen percent of the infantile nystagmus syndrome population had either the periodic or aperiodic form. A changing null period is often clinically missed because of long or irregular cycles, decreased acuity, associated strabismus, and either a nonexistent or inconsistent head posture. The changing null period is easier to recognize using eye movement recordings or if the non-preferred eye is occluded and the preferred eye is examined with the head straight and gaze in primary position for at least 5 to 7 minutes. The recognition of this variant has profound treatment implications.

  9. Ocular Vestibular Evoked Myogenic Potentials in Response to Three Test Positions and Two Frequencies

    PubMed Central

    Todai, Janvi K.; Congdon, Sharon L.; Sangi-Haghpeykar, Haleh; Cohen, Helen S.

    2014-01-01

    Objective To determine how eye closure, test positions, and stimulus frequencies influence ocular vestibular evoked myogenic potentials. Study Design This study used a within-subjects repeated measures design. Methods Twenty asymptomatic subjects were each tested on ocular vestibular evoked myogenic potentials in three head/eye conditions at 500 Hz and 1000 Hz using air-conducted sound: 1) Sitting upright, head erect, eyes open, looking up. 2) Lying supine, neck flexed 30 degrees, eyes open and looking up. 3) Lying supine, neck flexed 30 degrees, eyes closed and relaxed. Four dependent variables measured were n10, p16, amplitude, and threshold. Results The supine position/ eyes open was comparable to sitting/ eyes open and better than supine/ eyes closed. Eyes closed resulted in lower amplitude, higher threshold, and prolonged latency. Significantly fewer subjects provided responses with eyes closed than with eyes open. No significant differences were found between both eyes open conditions. Both n10 and p16 were lower at 1000 Hz than at 500 Hz. Amplitude and threshold were higher at 1000 Hz than at 500 Hz. Conclusion Supine eyes open is a reliable alternative to sitting eyes open in patients who cannot maintain a seated position. Testing at 1000 Hz provides a larger response with a faster onset that fatigues faster than at 500 Hz. The increased variability and decreased response in the eyes closed position suggest that the eyes closed position is not reliable. PMID:24178911

  10. [Diagnosis and treatment of strabismus caused by nasal endoscopic surgery].

    PubMed

    Ai, L K; Wu, X; Wang, J N; Li, J; Wu, Y; Zhou, J; Song, W X; Guo, R L

    2017-12-11

    Objective: Strabismus with diplopia is the main orbital complication of functional endoscopic sinus surgery (FESS). This study was to analyze clinical findings, treatment and outcomes of such cases. Methods: Retrospective case series. Twenty-three cases were divided into 3 groups based on the disease severity: group A, partial transection of the medial rectus muscle, group B, complete transection of the medical rectus, group C, transection of the medial rectus combined with the other orbital injuries. Complete ophthalmology examinations, including eye alignment, eye motility, force duction test, force generation test, general eye exam, and medical imaging (orbital CT or MRI), were performed for each case. The treatment included botulinum toxin (Botox) injection to the lateral rectus muscle, transposition of the vertical rectus muscle, and orbital surgery if needed. Results: In group A with Botox injection, all the cases achieved single vision in primary position, but still remained some adduction weakness. In group B treated by vertical transposition surgery combined with Botox, 22% of the cases got single vision in primary gaze. In group C, even with more efforts of treatment, the cases with orbital injury can only get cosmetic improvement, and diplopia and adduction dysfunction were found in most cases. Conclusions: Due to the variety of the complications of FESS, force duction test is a crucial exam to detect the direction and severity of synechia in the orbit, which will give solid information to surgery approach as well as prognosis. Botox injection at early stage will minimize the contraction of antagonist lateral rectus, helping to postpone the transposition surgery which may cause anterior segment ischemia when performed right after the medial rectus transection injury. Botox may even reduce the synechia by minimizing the scarring process. Partial vertical rectus transposition combined with muscle resection may effectively correct the eye misalignment in primary gaze and improve eye motility. The prognosis of FESS induced orbital complications is quite related with the severity of the injury. Botox combined with surgery may help medial rectus transection cases to achieve single vision in primary gaze, but when there is any other orbital injury, treatment may only improve cosmetic appearance. (Chin J Ophthalmol, 2017, 53: 917-923) .

  11. On the feasibility of utilizing active personal dosimeters worn on the chest to estimate occupational eye lens dose in x-ray angiography.

    PubMed

    Omar, Artur; Marteinsdottir, Maria; Kadesjö, Nils; Fransson, Annette

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has recommended that the occupational dose limit to the eye lens be substantially reduced. To ensure compliance with these recommendations, monitoring of the occupational eye lens dose is essential in certain hospital work environments. For assessment of the eye lens dose it is recommended to use a supplementary dosimeter placed at a position adjacent to the eye(s). Wearing a dosimeter at eye level can, however, be impractical and distributing and managing additional dosimeters over long periods of time is cumbersome and costly for large clinical sites. An attractive alternative is to utilize active personal dosimeters (APDs), which are routinely used by clinical staff for real-time monitoring of the personal dose equivalent rate (H(p)(10)). In this work, a formalism for the determination of eye lens dose from the response of such APD's worn on the chest is proposed and evaluated. The evaluation is based on both phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. The main results show that the eye lens dose to the primary operator and to the assisting clinical staff can be conservatively estimated from the APD response as D(eye)(conductor) = 2.0 APD chest and D(eye)(assisting) = 1.0 APD chest, respectively. However, care should be exercised for particularly short assisting staff and if radiation protection shields are misused. These concerns can be greatly mitigated if the clinical staff are provided with adequate radiation protection training.

  12. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery☆

    PubMed Central

    Arba-Mosquera, Samuel; Aslanides, Ioannis M.

    2012-01-01

    Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  13. The Efficacy of Bilateral Lateral Rectus Recession According to Secondary Deviation Measurements in Unilateral Exotropic Duane Retraction Syndrome.

    PubMed

    Mezad-Koursh, Daphna; Leshno, Ari; Klein, Ainat; Stolovich, Chaim

    2018-01-01

    To evaluate the surgical results of asymmetric bilateral lateral rectus recession in exotropic Duane retraction syndrome with abnormal face turn toward the opposite side according to secondary deviation measurements. Retrospective chart review. Seven cases of unilateral exotropic Duane retraction syndrome were reviewed. All cases had globe retraction on adduction and exotropia with limited adduction, five of which also had mild limitation of abduction. Four cases had upshoot/downshoot on adduction and all patients had face turn. Exotropia was measured in forced primary position. The average lateral rectus recession was 6.36 mm (range: 5.5 to 7.5 mm) in the affected eye and 7.36 mm (range: 6.5 to 8.5 mm) in the healthy eye. The mean follow-up period was 282 days. Mean exotropia in the forced primary position improved from 27.9 ± 5.7 prism diopters (PD) preoperatively to 7.9 ± 16.8 PD postoperatively (P = .025). Head position resolved completely in all but one case (P =.031). There were no significant changes in ductions. The results suggest that asymmetric bilateral lateral rectus recession in exotropic Duane retraction syndrome with abnormal head turn posture successfully eliminates abnormal head turn posture and exotropia in most cases. [J Pediatr Ophthalmol Strabismus. 2018;55(1):47-52.]. Copyright 2017, SLACK Incorporated.

  14. Characterisation of myofibroblasts in fibrovascular tissues of primary and recurrent pterygia

    PubMed Central

    Touhami, A; Di Pascuale, M A; Kawatika, T; Valle, M Del; Rosa, R H; Dubovy, S; Tseng, S C G

    2005-01-01

    Aims: To determine the presence and origin of myofibroblasts in pterygia. Methods: 86 specimens including head, body, and fibrovascular tissue from 52 primary and 34 recurrent pterygia and five exenterated eyes without pterygia were searched for the origin of myofibroblasts. All tissues were subjected to haematoxylin and eosin staining, immunohistochemistry using antibodies against alpha smooth muscle actin (α-SMA), desmin, vimentin, and caldesmon, and transmission electron microscopy (TEM). The phenotype of fibroblasts subcultured in a serum free medium from pterygium fibrovascular tissues was characterised by the above antibodies. Bundles of dense fibrous tissues were noted in 86% of the fibrovascular tissue specimens evaluated. Cells within these bundles were characterised as myofibroblasts based on positive staining to α-SMA, but negative to desmin and caldesmon, markers for smooth muscle cells. Interestingly, positive α-SMA staining was also found in the periorbital fibroadipose tissue posterior to Tenon’s capsule near the nasal conjunctiva in all exenterated specimens. All first passage fibroblasts expressed vimentin, some were positive to α-SMA, but all were negative to desmin or caldesmon. Cells in pterygium fibrovascular tissues showed ultrastructural features of intracytoplasmic bundles of microfilaments, consistent with myofibroblastic differentiation. Conclusion: These studies collectively demonstrate the presence of contractile myofibroblasts bundle in pterygia and in the periorbital fibroadipose tissue posterior to Tenon’s capsule of exenterated eyes without pterygium. PMID:15722301

  15. Diagnosis of retinal detachments by a tele-ophthalmology screening program.

    PubMed

    McCord, Sarah A; Lynch, Mary G; Maa, April Y

    2018-01-01

    In 2015, a tele-ophthalmology program was undertaken at the Atlanta Veterans Affairs Medical Center to provide screening eye care for veterans in their primary care clinics. Though this program was developed as a screening tool, the availability of these services in primary care clinics has enabled triage of certain acute eye complaints. These case reports describe two patients who were diagnosed with retinal detachments through this program, although their primary care providers had triaged them as requiring non-urgent referrals to the eye clinic. Although many patients are seen for acute ocular complaints in primary care clinics and emergency departments, providers in such settings may lack the ability to adequately examine eyes and thus triage ocular complaints. These cases demonstrate the ability of tele-ophthalmology to assist in diagnosing urgent ocular conditions in primary care clinics. Though tele-ophthalmology has been accepted in some parts of the world, in the United States of America it remains widely underutilized. These cases highlight the ability of tele-ophthalmology to close the gap in acute eye care coverage that exists in the USA, most prominently in rural regions.

  16. Combined influence of vergence and eye position on three-dimensional vestibulo-ocular reflex in the monkey.

    PubMed

    Misslisch, H; Hess, B J M

    2002-11-01

    This study examined two kinematical features of the rotational vestibulo-ocular reflex (VOR) of the monkey in near vision. First, is there an effect of eye position on the axes of eye rotation during yaw, pitch and roll head rotations when the eyes are converged to fixate near targets? Second, do the three-dimensional positions of the left and right eye during yaw and roll head rotations obey the binocular extension of Listing's law (L2), showing eye position planes that rotate temporally by a quarter as far as the angle of horizontal vergence? Animals fixated near visual targets requiring 17 or 8.5 degrees vergence and placed at straight ahead, 20 degrees up, down, left, or right during yaw, pitch, and roll head rotations at 1 Hz. The 17 degrees vergence experiments were performed both with and without a structured visual background, the 8.5 degrees vergence experiments with a visual background only. A 40 degrees horizontal change in eye position never influenced the axis of eye rotation produced by the VOR during pitch head rotation. Eye position did not affect the VOR eye rotation axes, which stayed aligned with the yaw and roll head rotation axes, when torsional gain was high. If torsional gain was low, eccentric eye positions produced yaw and roll VOR eye rotation axes that tilted somewhat in the directions predicted by Listing's law, i.e., with or opposite to gaze during yaw or roll. These findings were seen in both visual conditions and in both vergence experiments. During yaw and roll head rotations with a 40 degrees vertical change in gaze, torsional eye position followed on average the prediction of L2: the left eye showed counterclockwise (ex-) torsion in down gaze and clockwise (in-) torsion in up gaze and vice versa for the right eye. In other words, the left and right eye's position plane rotated temporally by about a quarter of the horizontal vergence angle. Our results indicate that torsional gain is the central mechanism by which the brain adjusts the retinal image stabilizing function of the VOR both in far and near vision and the three dimensional eye positions during yaw and roll head rotations in near vision follow on average the predictions of L2, a kinematic pattern that is maintained by the saccadic/quick phase system.

  17. The biometric study in different stages of primary angle-closure glaucoma

    PubMed Central

    Chen, Y-Y; Chen, Y-Y; Sheu, S-J; Chou, P

    2013-01-01

    Purpose This study compared the general and ocular biometric characteristics of normal, primary angle closure (PAC), and primary angle-closure glaucoma (PACG) patients to better understand the possible relationship between differences in ocular parameters that might predict risk for PACG in PAC patients. Methods One hundred normal, 90 PAC, and 90 PACG eyes were retrospectively reviewed. General characteristics such as age, gender, body height, body weight, blood pressure, pulse, systemic diseases, and education level were recorded. Ocular findings included visual acuity, intraocular pressure, refraction, cup to disc ratio, and ocular biometry. Ocular biometry was obtained by A-scan ultrasonography (Digital A/B scan 5500; Sonomed Inc., Lake Success, NY, USA). The parameters recorded were anterior chamber depth (ACD), lens thickness (LT), axial length (AXL), lens/axial length factor (LAF), and relative lens position (RLP). Results Although the controls, PAC group, and PACG group were found to be significantly different in age (62.7±9.8; 65.3±7.5; and 66.0±7.4, respectively), there were no gender differences. With regard to ocular parameters, the ACD tended to decrease and the LT and LAF tended to increase from normal to PAC to PACG. The eyes of the PACG group had significantly shallower ACD (P<0.001) and thicker lens (P<0.001) than those of the PAC group. While PAC had similar lens position to the control group, PACG had more anteriorly positioned lens than the PAC group (P<0.001). Logistic regression analysis found a significant association between a decrease in ACD and increased risk of PACG (odds ratio (OR)=3.59 for 0.2 mm decrease in ACD) as well as a significant association between an increase in LT and increased risk of PACG (OR=1.30). Conclusions In addition to LT, a shallower ACD owing to a change in RLP may have a role in the progression from PAC to PACG. Owing to the differences of certain biometric characteristics between PAC and PACG, A-scan ultrasonography might potentially be used for the early detection of PACG in PAC eyes. PMID:23788204

  18. Patients undergoing long-term treatment with antihypertensive eye drops responded positively with respect to their ocular surface disorder to oral supplementation with antioxidants and essential fatty acids.

    PubMed

    Galbis-Estrada, Carmen; Pinazo-Durán, Maria D; Cantú-Dibildox, Jorge; Marco-Ramírez, Carla; Díaz-Llópis, Manuel; Benítez-del-Castillo, Javier

    2013-01-01

    Glaucoma and dry eye disorders (DEDs) are frequent comorbidities. The antioxidant and anti-inflammatory properties of essential polyunsaturated fatty acids have been extensively studied in relation to eye diseases. Our objective was to determine the effects of oral supplementation with a combined formulation of antioxidants and essential polyunsaturated fatty acids on expression of cytokines and chemokines in tears from patients with DEDs or primary open-angle glaucoma (POAG). Participants (n = 97) were distributed into three groups: (1) individuals with nonsevere DEDs (DEDG), (2) individuals with nonadvanced POAG (POAGG), and (3) healthy controls. These groups were randomized into two subgroups: one received a daily antioxidant and essential polyunsaturated fatty acid supplement (two pills) for 3 months (+S), and the other did not (-NS). Participants were interviewed and ophthalmologically examined. Concentrations of specific cytokines and chemokines in reflex tears were determined by multiplexed particle-based flow cytometry. The data were analyzed statistically (SPSS version 15.0). Comparison of the results from the DEDG and POAGG patients showed significant differences in tear expression of granulocyte-macrophage colony-stimulating factor (P = 0.008), tumor necrosis factor α (P = 0.005), vascular endothelial growth factor (P = 0.038), interleukin-4 (P = 0.030), and interleukin-6 (P = 0.044). The main signs and symptoms of dry eyes such as dryness, burning, photophobia, eye heaviness, and blurred vision, as well as positive changes in eyelashes, hair, nails and skin, were significantly improved in DEDG +S and POAGG +S patients relative to unsupplemented patients. Inflammation biomarkers were differentially expressed in glaucomatous tears, but the differences changed upon antioxidant/essential polyunsaturated fatty acid supplementation. Chronic instillation of antihypertensive eye drops must be considered for integrating protocols to glaucoma standards of care.

  19. Secondary membrane formation after cataract surgery with primary intraocular lens implantation in children.

    PubMed

    Bar-Sela, Shai M; Har-Noy, Nurit Birman; Spierer, Abraham

    2014-08-01

    To evaluate the risk factors for secondary membrane (SM) formation after congenital cataract surgery with intraocular lens (IOL) implantation. A retrospective non-interventional comparative study. Thirty-nine patients (63 eyes) aged 1-135 months. The study included patients who underwent cataract extraction and primary IOL implantation between 1994 and 2001 at the University Hospital. The postoperative follow-up was 6-24 months. Thirty-three eyes received a poly(methyl methacrylate) (PMMA) IOL without square edges, 29 eyes received a hydrophobic acrylic IOL with truncated square edges (AcrySof), and there was no data for IOL type in one eye. Thirty-nine eyes had primary posterior capsulotomy (PPC) and anterior vitrectomy (AV) and in 24 eyes the posterior capsule was left intact. Cox proportional hazard regression analysis was performed to identify significant risk factors for SM formation, and Wilcoxon test to evaluate the difference in time from surgery to SM formation. SM developed in 24 eyes (38 %)--58 % of eyes with an intact posterior capsule and 26 % of eyes having PPC and AV, 42 % of eyes with a PMMA IOL, and 34 % of eyes with an AcrySof lens. In multivariate Cox regression analysis intraoperative PPC and AV (P = 0.02) and AcrySof lens implantation (P = 0.097) were associated with decreased postoperative incidence of SM formation. Median time until SM development was 2.9 months with PMMA IOLs (range 1-17 months) and 6 months with AcrySof lenses (range 1-21.8 months) (P = 0.037). Posterior capsule management as well as IOL design and material influence the incidence and the timing of SM formation after primary IOL implantation in children.

  20. Constitutive expression of HCA(2) in human retina and primary human retinal pigment epithelial cells.

    PubMed

    Yu, Alice L; Birke, Kerstin; Lorenz, Reinhard L; Welge-Lussen, Ulrich

    2014-05-01

    HCA2, a receptor of β-hydroxybutyrate and niacin, has recently been described in mouse retina and immortalized human retinal pigment epithelial (RPE) cell lines. As HCA2 might be a pharmacologic target, e.g. in diabetic retinopathy, we studied its expression in human retina and primary human RPE cells. Paraffin sections of human retina and primary human RPE cells were obtained from human donor eyes. Expression of HCA2 in human retina was investigated by immunohistochemistry of paraffin sections and by RT-PCR. HCA2 expression in primary human RPE cells was examined by immunocytochemistry and by Western-blot analysis. Positive immunohistochemical staining for HCA2 was found in paraffin sections of human retina, and positive immunocytochemical staining for HCA2 in primary human RPE cells. RT-PCR analysis detected mRNA expression of HCA2 in human retina. The expression of HCA2 protein was found in primary human RPE cells. Based on these results, HCA2 appears to be constitutively expressed in human retina and in primary human RPE cells. Although its functional role is still unknown, HCA2 may be potentially involved in the pathogenesis of various retinopathies and may offer a new therapeutic target.

  1. Choroid vascular occlusion and ischemic optic neuropathy after facial calcium hydroxyapatite injection- a case report.

    PubMed

    Chou, Chien-Chih; Chen, Hsin-Han; Tsai, Yi-Yu; Li, You-Ling; Lin, Hui-Ju

    2015-03-08

    We reported a case of sudden monocular vision loss after calcium hydroxyapatite (CaHA) injection into the nasal tip and dorsum with detailed retina images. A healthy, 35-year-old woman received CaHA filler injection for nose augmentation. Ten minutes after the procedure, she developed nausea, vomiting, headache, ptosis, and left periorbital pain. After 30 minutes, she complained of progressively blurring vision in the left eye. The best-corrected visual acuity (BCVA) in her left eye was 30 cm ahead of hand motion. Left exotropia was noted in primary gaze. Limitations in adduction, supraduction, and infraduction of the left eye were also observed. Slit lamp examination of the left eye revealed a pink conjunctiva, a clear cornea, a mild anterior chamber reaction, a sluggish papillary light reflex, and a semi-dilated pupil. A positive relative afferent pupillary defect was observed in the left eye. Fundus examination revealed optic disc edema and some linear whitish opacity over the superior and temporal sites in the left eye, suggesting multiple CaHA emboli in the choroid vessels. Although the majority of adverse reactions are mild and transient, surgeons should be alert about extremely rare serious adverse events such as visual loss.

  2. Comparison of the diagnostic ability of Moorfield’s regression analysis and glaucoma probability score using Heidelberg retinal tomograph III in eyes with primary open angle glaucoma

    PubMed Central

    Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita

    2010-01-01

    Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832

  3. Risk factors for poor outcomes in patients with open-globe injuries

    PubMed Central

    Page, Rita D; Gupta, Sumeet K; Jenkins, Thomas L; Karcioglu, Zeynel A

    2016-01-01

    Purpose The aim of this study was to identify the risk factors that are predictive of poor outcomes in penetrating globe trauma. Patients and methods This retrospective case series evaluated 103 eyes that had been surgically treated for an open-globe injury from 2007 to 2010 at the eye clinic of the University of Virginia. A total of 64 eyes with complete medical records and at least 6 months of follow-up were included in the study. Four risk factors (preoperative best-corrected visual acuity [pre-op BCVA], ocular trauma score [OTS], zone of injury [ZOI], and time lapse [TL] between injury and primary repair) and three outcomes (final BCVA, monthly rate of additional surgeries [MRAS], and enucleation) were identified for analysis. Results Pre-op BCVA was positively associated with MRAS, final BCVA, and enucleation. Calculated OTS was negatively associated with the outcome variables. No association was found between TL and ZOI with the outcome variables. Further, age and predictor variable-adjusted analyses showed pre-op BCVA to be independently positively associated with MRAS (P=0.008) and with final BCVA (P<0.001), while the calculated OTS was independently negatively associated with final BCVA (P<0.001), but not uniquely associated with MRAS (P=0.530). Conclusion Pre-op BCVA and OTS are best correlated with prognosis in open-globe injuries. However, no conventional features reliably predict the outcome of traumatized eyes. PMID:27536059

  4. The biomechanical significance of pulley on binocular vision.

    PubMed

    Guo, Hongmei; Gao, Zhipeng; Chen, Weiyi

    2016-12-28

    Pulleys have been reported as the functional origins of the rectus extraocular muscles (EOMs). However, biomechanical significance of pulleys on binocular vision has not been reported. Three eye movement models, i.e., non-pulley model, passive-pulley model, and active-pulley model, are used to simulate the horizontal movement of the eyes from the primary position to the left direction in the range of 1°-30°. The resultant forces of six EOMs along both orthogonal directions (i.e., the x-axis and y-axis defined in this paper) in the horizontal plane are calculated using the three models. The resultant force along the y-axis of the left eye for non-pulley model are significantly larger than that of the other two pulley models. The difference of the force, between the left eye and the right eye in non-pulley model, is larger than those in the other two pulley models along x-axis and y-axis. The pulley models present more biomechanical advantage on the horizontally binocular vision than the non-pulley model. Combining with the previous imaging evidences of pulleys, the results show that pulley model coincides well with the real physiological conditions.

  5. Assessment of Annual Diabetic Eye Examination Using Telemedicine Technology Among Underserved Patients in Primary Care Setting.

    PubMed

    Hatef, Elham; Alexander, Miriam; Vanderver, Bruce G; Fagan, Peter; Albert, Michael

    2017-01-01

    Digital retinal imaging with the application of telemedicine technology shows promising results for screening of diabetic retinopathy in the primary care setting without requiring an ophthalmologist on site. We assessed whether the establishment of telemedicine technology was an effective and efficient way to increase completion of annual eye examinations among underserved, low-income (Medicaid) diabetic patients. A cross-sectional study in a primary care setting. Health care claims data were collected before the establishment of telemedicine technology in 2010 and after its implementation in 2012 for Medicaid patients at East Baltimore Medical Center (EBMC), an urban health center that is part of Johns Hopkins Health System. The primary outcome measure was the compliance rate of patients with diabetic eye examinations; calculated as the number of diabetic patients with a completed telemedicine eye examination, divided by the total number of diabetic patients. In 2010, EBMC treated 213 Medicaid diabetic patients and in 2012 treated 228 Medicaid patients. In 2010, 47.89% of patients completed their annual diabetic eye examination while in 2012 it was 78.07% ( P < 0.001). After adjustment for age, gender, HgBA1C, disease severity, using resource utilization band score as a proxy, and medication possession ratio; telemedicine technology significantly increased the compliance (odds ratio: 4.98, P < 0.001). Adherence to annual eye examinations is low in the studied Medicaid diabetic population. Telemedicine technology in a primary care setting can increase compliance with annual eye examinations.

  6. Eye position modulates the electromyographic responses of neck muscles to electrical stimulation of the superior colliculus in the alert cat.

    PubMed

    Hadjidimitrakis, K; Moschovakis, A K; Dalezios, Y; Grantyn, A

    2007-05-01

    Rapid gaze shifts are often accomplished with coordinated movements of the eyes and head, the relative amplitude of which depends on the starting position of the eyes. The size of gaze shifts is determined by the superior colliculus (SC) but additional processing in the lower brain stem is needed to determine the relative contributions of eye and head components. Models of eye-head coordination often assume that the strength of the command sent to the head controllers is modified by a signal indicative of the eye position. Evidence in favor of this hypothesis has been recently obtained in a study of phasic electromyographic (EMG) responses to stimulation of the SC in head-restrained monkeys (Corneil et al. in J Neurophysiol 88:2000-2018, 2002b). Bearing in mind that the patterns of eye-head coordination are not the same in all species and because the eye position sensitivity of phasic EMG responses has not been systematically investigated in cats, in the present study we used cats to address this issue. We stimulated electrically the intermediate and deep layers of the caudal SC in alert cats and recorded the EMG responses of neck muscles with horizontal and vertical pulling directions. Our data demonstrate that phasic, short latency EMG responses can be modulated by the eye position such that they increase as the eye occupies more and more eccentric positions in the pulling direction of the muscle tested. However, the influence of the eye position is rather modest, typically accounting for only 10-50% of the variance of EMG response amplitude. Responses evoked from several SC sites were not modulated by the eye position.

  7. The effect of UV-blocking contact lenses as a therapy for canine chronic superficial keratitis.

    PubMed

    Denk, Nora; Fritsche, Jens; Reese, Sven

    2011-05-01

    To evaluate the effect of UV-blocking soft contact lenses in treatment for chronic superficial keratitus (CSK). Twenty six dogs with CSK were treated continuously with UV-blocking contact lenses for 6 months. A contact lens was placed on one eye of each dog; the other eye remained without a lens as a control eye. After this primary study, five of the dogs were further treated and they wore then contact lenses in both eyes. Continuously, all patients were concurrently treated topically with cyclosporine. The contact lenses were changed every 4 weeks and an ophthalmic examination performed. Evaluation criteria included corneal alterations as pigmentation, edema, pannus and vascularization. To determine the transmittance characteristics of the contact lenses before and after use, 32 contact lenses were measured with a UV-vis-NIR spectrophotometer. Pigmentation increased in eyes wearing lenses and in control eyes over the evaluation period of 6 months. Corneal edema increased in the eyes wearing lenses, but remained unaffected in the control eyes. A significant difference in the incidence of pannus and the extent of corneal vascularisation could not be evaluated. Adverse effects were noted in six cases (corneal edema and vascularisation, conjunctivitis, blepharospasm). All new lenses studied reduced UV-radiation to a safe level, whereas used lenses did not maintain their transmittance characteristics. No positive effect of UV-blocking contact lenses could be proven with the study design used. © 2011 American College of Veterinary Ophthalmologists.

  8. Laser in situ keratomileusis enhancements with the Ziemer FEMTO LDV femtosecond laser following previous LASIK treatments.

    PubMed

    Pietilä, Juhani; Huhtala, Anne; Mäkinen, Petri; Uusitalo, Hannu

    2013-02-01

    The aim of this paper is to present the accuracy, predictability, and safety outcomes of LASIK enhancements performed with the FEMTO LDV femtosecond laser (Ziemer Ophthalmic Systems, Port, Switzerland) and the Allegretto Wave Concerto 500 Hz excimer laser (Wavelight AG, Erlangen, Germany), following previous LASIK treatments. FEMTO LDV was used for flap creation in 85 previously LASIK-treated eyes of 62 patients. The intended flap thickness was 90 μm in 81 eyes and 140 μm in 4 eyes. The size of the suction ring was 9.0 mm in 72 eyes and 9.5 mm in 13 eyes. Flap dimensions were measured and correlated to preoperative characteristics. With the intended flap thickness of 90 μm in previously LASIK-treated eyes, the actual flap thickness was 90.2 ± 6.6 μm (range 80-122), and the flap diameter was 9.2 ± 0.2 mm (range 8.7-9.9). The mean hinge length was 4.0 ± 0.2 mm (range 3.0-4.8). Flap thickness correlated positively with patient age and hinge length. Complications were reported in 12 eyes (14.1 %). Most of the complications were very mild, and none of them prevented further refractive laser treatment. One eye lost two Snellen lines of best spectacle-corrected visual acuity. Femtosecond LASIK enhancement is warranted only in rare cases. Surgical experience is needed and special caution must be practiced. For cases of a primary free cap, femtosecond LASIK is not recommended.

  9. Cause of kinematic differences during centrifugal and centripetal saccades.

    PubMed

    Koene, Ansgar R; Erkelens, Casper J

    2002-06-01

    Measurements of eye movements have shown that centrifugal movements (i.e. away from the primary position) have a lower maximum velocity and a longer duration than centripetal movements (i.e. toward the primary position) of the same size. In 1988 Pelisson proposed that these kinematic differences might be caused by differences in the neural command signals, oculomotor mechanics or a combination of the two. By using the result of muscle force measurements that were made in recent years (Orbit 1.8 Gaze mechanics simulation, Eidactics, San Francisco, 1999) we simulated the muscle forces during centrifugal and centripetal saccades. Based on these simulations we show that the cause of the kinematic differences between the centrifugal and centripetal saccades is the non-linear force-velocity relationship (i.e. muscle viscosity) of the muscles.

  10. Intracapsular lensectomy and sulcus intraocular lens fixation in dogs with primary lens luxation or subluxation.

    PubMed

    Stuhr, Charles M; Schilke, Hillary K; Forte, Christina

    2009-01-01

    To evaluate the postoperative results of lensectomy and sulcus intraocular lens fixation (SIOLF) via an ab interno approach in dogs with progressive lens subluxation or early luxation. Retrospective study. Twenty eyes from 19 dogs presented to the Animal Eye Clinic for lens luxation or subluxation between 1999 and 2006. Medical records were reviewed to evaluate preoperative lens position, vision status, intraocular pressure (IOP), and whether surgery was performed on an emergent or elective nature. Lensectomy and SIOLF were performed and postoperative status including vision, glaucoma, and retinal detachment was assessed. Average age was 8.6 years (range 4-14 years) and 55% (11/20) were terriers. Patients were followed a mean of 29.2 months (range 1-92 months) after surgery. Retinal detachment or secondary glaucoma was observed in 1 of 20 (5%) and 5 of 20 (20%) eyes, respectively, with 1 of 20 (5%) exhibiting both. Mean preoperative IOP was 16 mmHg and preoperative lens position was equally divided between luxated and subluxated lenses. Surgery was performed more frequently as an elective procedure (18/20; 90%) due to normalized IOP vs. an emergency procedure (2/20; 10%). Vision was retained in 70% (14/20) of eyes with a mean time to vision loss of 41 months in the remaining eyes due to glaucoma, retinal detachment, or retinal degeneration. Complications of glaucoma and retinal detachment after SIOLF in this study were less when compared with previously reported incidence rates in the literature for lensectomy alone which may reflect improved patient selection.

  11. HUMAN EYE OPTICS: Determination of positions of optical elements of the human eye

    NASA Astrophysics Data System (ADS)

    Galetskii, S. O.; Cherezova, T. Yu

    2009-02-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.

  12. Outcomes of Retreatment after Aborted Laser In Situ Keratomileusis due to Flap Complications.

    PubMed

    Al-Mezaine, Hani S; Al-Amro, Saleh A; Al-Fadda, Abdulaziz; Al-Obeidan, Saleh

    2011-07-01

    To determine the refractive outcomes and complications of retreatment after aborted primary laser in situ keratomileusis (LASIK) due to flap complications. This retrospective study evaluated 50 retreated eyes that had flap complications during primary LASIK at the Eye Consultants Center in Riyadh, Saudi Arabia. Data were analyzed for patients with at least 3 months follow-up post retreatment. Thirty-three eyes of 31 consecutive patients with 3 months follow-up or later post retreatment were included. The primary LASIK was aborted due to incomplete flaps in 22 eyes (66.7%), buttonhole flaps in 7 eyes (21.2%), free partial flaps in 3 eyes (9.1%), and a free complete flap in 1 eye (3.0%). Twenty-two eyes (66.7%) were retreated with LASIK, and 11 eyes (33.3%) were retreated with surface ablation. The mean spherical equivalent (SE) was -0.23 ± 0.72 D, the mean astigmatism was -0.65 ± 0.89 D, and the mean loss of the best corrected visual acuity (BCVA) was 0.78 lines at the final postoperative visit. At the last postoperative visit, 20/30 or better BCVA was achieved in 90.1% of eyes that underwent retreatment with LASIK and in 91% of eyes that were retreated with surface ablation. There was no statistical difference in postoperative SE between eyes retreated with LASIK and eyes retreated with surface ablation (P = 0.610). There was no statistical difference in postoperative BCVA between eyes retreated with LASIK and those retreated with surface ablation (P = 0.756). There were no intraoperative complications and no eyes required a second retreatment. Creation of a flap after a previous intraoperative flap complication was not associated with any complications. The refractive outcomes of retreatment with LASIK or surface ablation were comparable and reasonably favorable.

  13. Knowledge and practices of teachers associated with eye health of primary school children in Rawalpindi, Pakistan.

    PubMed

    Habiba, Ume; Ormsby, Gail M; Butt, Zahid Ahmad; Afghani, Tayyab; Asif, Muhammad

    2017-01-01

    Teachers' perspectives on eye health can be limited, particularly in developing countries. The aim of this study was to assess teachers' knowledge and practices associated with eye health of primary students in Rawalpindi, Pakistan. This was a cross-sectional survey of primary school teachers. Simple random sampling technique was used to select 443 participants from 34 private and 17 public schools. A self-administered questionnaire was used. Teachers' knowledge ranged from "high" (35.89%), "moderate" (49.89%), and "low" (14.22%). Teachers' practices associated with students' eye health ranged from "high" (10.16%), "moderate" (23.02%), and "low" (66.82%). The teachers' knowledge index scores increased 4.28 points with successive age groups and increased 2.41 points with each successive level of education. For teachers whose close relatives experienced eye disease, their knowledge index score was 4.51 points higher than those teachers whose relatives never had any eye disease. Teachers' age, education level, and their close relatives experiencing eye disease were significant predictors of their knowledge ( R 2 = 0.087, P < 0.001). Female teachers' practices index score was 10.35 points higher than the male teachers and public school teachers had 10.13 points higher than the private school teachers. Teachers' gender and type of school were significant predictors of their practices ( R 2 = 0.06, P < 0.001). There was a significant gap among primary school teachers' knowledge and practices related to students' eye health. Innovative strategies are needed to improve how teachers address students' eye health issues in the classroom.

  14. Vitreoretinal interface abnormalities in middle-aged adults with visual impairment in the UK Biobank study: prevalence, impact on visual acuity and associations.

    PubMed

    McKibbin, Martin; Farragher, Tracey; Shickle, Darren

    2017-01-01

    The aim of this study was to determine the prevalence of vitreoretinal interface abnormalities (VRIA), the degree of visual impairment and associations with VRIA among adults, aged 40-69 years, in the UK Biobank study. Colour fundus photographs and spectral domain optical coherence tomography images were graded for 25% of the 8359 UK Biobank participants with mild visual impairment or worse (LogMAR >0.3 or Snellen <6/12) in at least one eye. The prevalence and contribution of VRIA to visual impairment was determined and multinomial logistic regression models were used to investigate association with known risk factors and other predetermined socioeconomic, biometric, lifestyle and medical variables for cases and matched controls. The minimum prevalence of any VRIA was 17.6% and 8.1% in the eyes with and without visual impairment, respectively. VRIA were identified as the primary cause of visual impairment in 3.6% of eyes. Although epiretinal membrane and vitreomacular traction were the most common VRIA, the degree of visual impairment was typically milder with these than with other VRIA. Visual impairment with a VRIA was positively associated with increasing age (relative risk ratio (RRR) 1.22 (95% CI 1.07 to 1.40)), female gender (RRR 1.28; 1.08 to 1.52) and Asian or Asian British ethnicity (RRR 1.60; 1.10 to 2.32). VRIA are common in middle-aged adults in the UK Biobank study, especially in eyes with visual impairment. VRIA were considered to be the primary cause of visual impairment in 3.6% of all eyes with visual impairment, although there was variation in the degree of visual impairment for each type of VRIA.

  15. Vitreoretinal interface abnormalities in middle-aged adults with visual impairment in the UK Biobank study: prevalence, impact on visual acuity and associations

    PubMed Central

    Farragher, Tracey; Shickle, Darren

    2017-01-01

    Objective The aim of this study was to determine the prevalence of vitreoretinal interface abnormalities (VRIA), the degree of visual impairment and associations with VRIA among adults, aged 40–69 years, in the UK Biobank study. Methods and analysis Colour fundus photographs and spectral domain optical coherence tomography images were graded for 25% of the 8359 UK Biobank participants with mild visual impairment or worse (LogMAR >0.3 or Snellen <6/12) in at least one eye. The prevalence and contribution of VRIA to visual impairment was determined and multinomial logistic regression models were used to investigate association with known risk factors and other predetermined socioeconomic, biometric, lifestyle and medical variables for cases and matched controls. Results The minimum prevalence of any VRIA was 17.6% and 8.1% in the eyes with and without visual impairment, respectively. VRIA were identified as the primary cause of visual impairment in 3.6% of eyes. Although epiretinal membrane and vitreomacular traction were the most common VRIA, the degree of visual impairment was typically milder with these than with other VRIA. Visual impairment with a VRIA was positively associated with increasing age (relative risk ratio (RRR) 1.22 (95% CI 1.07 to 1.40)), female gender (RRR 1.28; 1.08 to 1.52) and Asian or Asian British ethnicity (RRR 1.60; 1.10 to 2.32). Conclusions VRIA are common in middle-aged adults in the UK Biobank study, especially in eyes with visual impairment. VRIA were considered to be the primary cause of visual impairment in 3.6% of all eyes with visual impairment, although there was variation in the degree of visual impairment for each type of VRIA. PMID:29354705

  16. Comparison for aphasic and control subjects of eye movements hypothesized in neurolinguistic programming.

    PubMed

    Dooley, K O; Farmer, A

    1988-08-01

    Neurolinguistic programming's hypothesized eye movements were measured independently using videotapes of 10 nonfluent aphasic and 10 control subjects matched for age and sex. Chi-squared analysis indicated that eye-position responses were significantly different for the groups. Although earlier research has not supported the hypothesized eye positions for normal subjects, the present findings support the contention that eye-position responses may differ between neurologically normal and aphasic individuals.

  17. Sulfur hexafluoride (SF6) versus perfluoropropane (C3F8) tamponade and short term face-down position for macular hole repair: a randomized prospective study.

    PubMed

    Casini, Giamberto; Loiudice, Pasquale; De Cillà, Stefano; Radice, Paolo; Nardi, Marco

    2016-01-01

    To compare early visual and anatomical outcomes after either sulfur hexafluoride (SF 6 ) or perfluoropropane (C 3 F 8 ) tamponade for macular hole repair. 147 eyes affected by primary full-thickness macular hole underwent pars plana vitrectomy with dye assisted removal of the internal limiting membrane and gas tamponade. Prone position was prescribed for 48 h after surgery. All patients were divided into 3 groups depending on the size of the hole: small (<250 µm), medium (>250-<400 µm) or large (>400 µm). Eyes within the same group randomly received either SF 6 (70 eyes) or C 3 F 8 (77 eyes). A complete ophthalmic evaluation, including best corrected visual acuity and anatomic status of the macular holes, was conducted preoperatively, at 1 week and 1 month after surgery. Macular hole volume was calculated using optical coherence tomography scans. The Wilcoxon Signed Ranks Test, the Mann-Whitney Test, the Spearman's rank-order correlation coefficient and the study of variance for repeated measures were used for statistical analysis. Mean best-corrected visual acuity improved from 0.92 logMAR to 0.28 logMAR (P < 0.001). A reduction of the dimensions of macular holes was observed in all cases, with a total repair of 90 % (63/70 eyes) in the SF 6 group and 91 % in the C 3 F 8 group (70/77 eyes). There was a negative correlation between the initial minor diameter, the volume of the hole and the rate of anatomic success. Short-term anatomical and visual outcomes were similar in eyes treated with either SF 6 or C 3 F 8 , independently of the stage of the macular hole. The initial volume and the minor diameter of the hole may be considered as valid tools for predicting surgical success. Age and gender did not appear to have influenced the prognosis.

  18. Generating and Describing Affective Eye Behaviors

    NASA Astrophysics Data System (ADS)

    Mao, Xia; Li, Zheng

    The manner of a person's eye movement conveys much about nonverbal information and emotional intent beyond speech. This paper describes work on expressing emotion through eye behaviors in virtual agents based on the parameters selected from the AU-Coded facial expression database and real-time eye movement data (pupil size, blink rate and saccade). A rule-based approach to generate primary (joyful, sad, angry, afraid, disgusted and surprise) and intermediate emotions (emotions that can be represented as the mixture of two primary emotions) utilized the MPEG4 FAPs (facial animation parameters) is introduced. Meanwhile, based on our research, a scripting tool, named EEMML (Emotional Eye Movement Markup Language) that enables authors to describe and generate emotional eye movement of virtual agents, is proposed.

  19. deep-orange and carnation define distinct stages in late endosomal biogenesis in Drosophila melanogaster.

    PubMed

    Sriram, V; Krishnan, K S; Mayor, Satyajit

    2003-05-12

    Endosomal degradation is severely impaired in primary hemocytes from larvae of eye color mutants of Drosophila. Using high resolution imaging and immunofluorescence microscopy in these cells, products of eye color genes, deep-orange (dor) and carnation (car), are localized to large multivesicular Rab7-positive late endosomes containing Golgi-derived enzymes. These structures mature into small sized Dor-negative, Car-positive structures, which subsequently fuse to form tubular lysosomes. Defective endosomal degradation in mutant alleles of dor results from a failure of Golgi-derived vesicles to fuse with morphologically arrested Rab7-positive large sized endosomes, which are, however, normally acidified and mature with wild-type kinetics. This locates the site of Dor function to fusion of Golgi-derived vesicles with the large Rab7-positive endocytic compartments. In contrast, endosomal degradation is not considerably affected in car1 mutant; fusion of Golgi-derived vesicles and maturation of large sized endosomes is normal. However, removal of Dor from small sized Car-positive endosomes is slowed, and subsequent fusion with tubular lysosomes is abolished. Overexpression of Dor in car1 mutant aggravates this defect, implicating Car in the removal of Dor from endosomes. This suggests that, in addition to an independent role in fusion with tubular lysosomes, the Sec1p homologue, Car, regulates Dor function.

  20. [Dry eye syndrome in patients with primary open-angle glaucoma].

    PubMed

    Boyko, E V; Simakova, I L; Yakushev, D Yu; Ignat'ev, S A; Alekseev, I B; Mel'nikova, N V; Alyab'ev, M V; Mal'tsev, D S

    2015-01-01

    to determine the frequency and severity of dry eye syndrome (DES) in primary open-angle glaucoma (POAG) patients that are newly diagnosed or already receiving beta blocker instillation therapy. A total of 127 patients (190 eyes) with POAG were divided into two groups. Group 1 included 55 newly diagnosed patients (88 eyes), group 2-72 POAG patients (102 eyes) instilling timolol 0.5% twice daily into the affected eye. The control group included 20 patients (40 eyes) aged 60-88 years (73.6 ± 9.2 years on average) with early age-related cataract. DES was found in 69 POAG patients (79%) who was just starting their topical hypotensive therapy and 85 of those (84%) under treatment (p = 0.39). One should take into account when prescribing ocular hypotensive therapy that newly diagnosed POAG patients usually already suffer from a dry eye. The use of topical beta blockers that contain preservatives exacerbates dry eye signs and symptoms in these patients.

  1. Factors associated with severe dry eye in primary Sjögren's syndrome diagnosed patients.

    PubMed

    Fernandez Castro, Mónica; Sánchez-Piedra, Carlos; Andreu, Jose Luis; Martínez Taboada, Víctor; Olivé, Alejandro; Rosas, Jose

    2018-06-01

    Primary Sjögren's syndrome (pSS) is an autoimmune disease, characterized by lymphocytic infiltration of exocrine glands and other organs, resulting in dry eye, dry mouth and extraglandular systemic findings. To explore the association of severe or very severe dry eye with extraocular involvement in patients diagnosed with primary Sjögren's syndrome. SJOGRENSER registry is a multicenter cross-sectional study of pSS patients. For the construction of our main variable, severe/very severe dry eye, we used those variables that represented a degree 3-4 of severity according to the 2007 Dry Eye Workshop classification. First, bivariate logistic regression models were used to identify the effect of each independent variable on severe/very severe dry eye. Secondly, multivariate analysis using regression model was used to establish the independent effect of patient characteristics. Four hundred and thirty-seven patients were included in SJOGRENSER registry; 94% of the patients complained of dry eye and 16% developed corneal ulcer. Schirmer's test was pathological in 92% of the patients; 378 patients presented severe/very severe dry eye. Inflammatory articular involvement was significantly more frequent in patients with severe/very severe dry eye than in those without severe/very severe dry eye (82.5 vs 69.5%, p = 0,028). Inflammatory joint involvement was associated with severe/very severe dry eye in the multivariate analysis, OR 2.079 (95% CI 1.096-3.941). Severe or very severe dry eye is associated with the presence of inflammatory joint involvement in patients with pSS. These results suggest that a directed anamnesis including systemic comorbidities, such as the presence of inflammatory joint involvement or dry mouth in patients with dry eye, would be useful to suspect a pSS.

  2. Eye contrast polarity is critical for face recognition by infants.

    PubMed

    Otsuka, Yumiko; Motoyoshi, Isamu; Hill, Harold C; Kobayashi, Megumi; Kanazawa, So; Yamaguchi, Masami K

    2013-07-01

    Just as faces share the same basic arrangement of features, with two eyes above a nose above a mouth, human eyes all share the same basic contrast polarity relations, with a sclera lighter than an iris and a pupil, and this is unique among primates. The current study examined whether this bright-dark relationship of sclera to iris plays a critical role in face recognition from early in development. Specifically, we tested face discrimination in 7- and 8-month-old infants while independently manipulating the contrast polarity of the eye region and of the rest of the face. This gave four face contrast polarity conditions: fully positive condition, fully negative condition, positive face with negated eyes ("negative eyes") condition, and negated face with positive eyes ("positive eyes") condition. In a familiarization and novelty preference procedure, we found that 7- and 8-month-olds could discriminate between faces only when the contrast polarity of the eyes was preserved (positive) and that this did not depend on the contrast polarity of the rest of the face. This demonstrates the critical role of eye contrast polarity for face recognition in 7- and 8-month-olds and is consistent with previous findings for adults. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Knowledge, Attitude, and Perception of Barriers for Eye Care among Diabetic Persons Registered at Employee Health Department of a Tertiary Eye Hospital of Central Saudi Arabia.

    PubMed

    Al-Alawi, Abeer; Al-Hassan, Arif; Chauhan, Deepti; Al-Futais, Muneera; Khandekar, Rajiv

    2016-01-01

    To evaluate the level of knowledge, attitudes, and barriers to diabetic retinopathy (DR) screening among diabetic healthcare staff at a tertiary eye hospital in central Saudi Arabia. This was a descriptive survey using a closed-ended questionnaire. A. 5-grade. Likert scale was used for responses to each question. Data were collected on patient demographics and the status of diabetes. Survey responses related to knowledge, attitude, and barriers were grouped. The study sample was comprised of 45 diabetics employed at the hospital. The mean age was 49 ± 11 years and 33 diabetics were males. One-third of the study population was referred to the eye clinic for DR screening. DR screening was performed in 25% of diabetics over the previous year. Twenty-nine (64%; 95% confidence intervals: 50-78) participants had excellent knowledge of eyecare for diabetic complications. Thirteen percent of participants had a positive attitude toward periodic eye checkups. Travel distance to an eyecare unit, no referral from family physicians for annual eye checkups and the lack of availability of gender-specific eyecare professionals were the main perceived barriers. Annual DR screening needs to be promoted to primary healthcare providers and diabetic patients. Barriers should be addressed to improve the uptake of DR screening.

  4. Knowledge, Attitude, and Perception of Barriers for Eye Care among Diabetic Persons Registered at Employee Health Department of a Tertiary Eye Hospital of Central Saudi Arabia

    PubMed Central

    Al-Alawi, Abeer; Al-Hassan, Arif; Chauhan, Deepti; Al-Futais, Muneera; Khandekar, Rajiv

    2016-01-01

    Purpose: To evaluate the level of knowledge, attitudes, and barriers to diabetic retinopathy (DR) screening among diabetic healthcare staff at a tertiary eye hospital in central Saudi Arabia. Methods: This was a descriptive survey using a closed-ended questionnaire. A. 5-grade. Likert scale was used for responses to each question. Data were collected on patient demographics and the status of diabetes. Survey responses related to knowledge, attitude, and barriers were grouped. Results: The study sample was comprised of 45 diabetics employed at the hospital. The mean age was 49 ± 11 years and 33 diabetics were males. One-third of the study population was referred to the eye clinic for DR screening. DR screening was performed in 25% of diabetics over the previous year. Twenty-nine (64%; 95% confidence intervals: 50–78) participants had excellent knowledge of eyecare for diabetic complications. Thirteen percent of participants had a positive attitude toward periodic eye checkups. Travel distance to an eyecare unit, no referral from family physicians for annual eye checkups and the lack of availability of gender-specific eyecare professionals were the main perceived barriers. Conclusion: Annual DR screening needs to be promoted to primary healthcare providers and diabetic patients. Barriers should be addressed to improve the uptake of DR screening. PMID:26957842

  5. Internal limiting membrane flap transposition for surgical repair of macular holes in primary surgery and in persistent macular holes.

    PubMed

    Leisser, Christoph; Hirnschall, Nino; Döller, Birgit; Varsits, Ralph; Ullrich, Marlies; Kefer, Katharina; Findl, Oliver

    2018-03-01

    Classical or temporal internal limiting membrane (ILM) flap transposition with air or gas tamponade are current trends with the potential to improve surgical results, especially in cases with large macular holes. A prospective case series included patients with idiopathic macular holes or persistent macular holes after 23-G pars plana vitrectomy (PPV) and ILM peeling with gas tamponade. In all patients, 23-G PPV and ILM peeling with ILM flap transposition with gas tamponade and postoperative face-down position was performed. In 7 of 9 eyes, temporal ILM flap transposition combined with pedicle ILM flap could be successfully performed and macular holes were closed in all eyes after surgery. The remaining 2 eyes were converted to pedicle ILM flap transposition with macular hole closure after surgery. Three eyes were scheduled as pedicle ILM flap transposition due to previous ILM peeling. In 2 of these eyes, the macular hole could be closed with pedicle ILM flap transposition. In 3 eyes, free ILM flap transposition was performed and in 2 of these eyes macular hole could be closed after surgery, whereas in 1 eye a second surgery, performed as pedicle ILM flap transposition, was performed and led to successful macular hole closure. Use of ILM flaps in surgical repair of macular hole surgery is a new option of treatment with excellent results independent of the diameter of macular holes. For patients with persistent macular holes, pedicle ILM flap transposition or free ILM flap transposition are surgical options.

  6. Assessing Suppression in Amblyopic Children With a Dichoptic Eye Chart.

    PubMed

    Birch, Eileen E; Morale, Sarah E; Jost, Reed M; De La Cruz, Angie; Kelly, Krista R; Wang, Yi-Zhong; Bex, Peter J

    2016-10-01

    Suppression has a key role in the etiology of amblyopia, and contrast-balanced binocular treatment can overcome suppression and improve visual acuity. Quantitative assessment of suppression could have a role in managing amblyopia. We describe a novel eye chart to assess suppression in children. We enrolled 100 children (7-12 years; 63 amblyopic, 25 nonamblyopic with strabismus or anisometropia, 12 controls) in the primary cohort and 22 children (3-6 years; 13 amblyopic, 9 nonamblyopic) in a secondary cohort. Letters were presented on a dichoptic display (5 letters per line). Children wore polarized glasses so that each eye saw a different letter chart. At each position, the identity of the letter and its contrast on each eye's chart differed. Children read 8 lines of letters for each of 3 letter sizes. The contrast balance ratio was the ratio at which 50% of letters seen by the amblyopic eye were reported. Amblyopic children had significantly higher contrast balance ratios for all letter sizes compared to nonamblyopic children and controls, requiring 4.6 to 5.6 times more contrast in the amblyopic eye compared to the fellow eye (P < 0.0001). Amblyopic eye visual acuity was correlated with contrast balance ratio (r ranged from 0.49-0.57 for the 3 letter sizes). Change in visual acuity with amblyopia treatment was correlated with change in contrast balance ratio (r ranged from 0.43-0.62 for the 3 letter sizes). Severity of suppression can be monitored as part of a routine clinical exam in the management of amblyopia in children.

  7. Assessing Suppression in Amblyopic Children With a Dichoptic Eye Chart

    PubMed Central

    Birch, Eileen E.; Morale, Sarah E.; Jost, Reed M.; De La Cruz, Angie; Kelly, Krista R.; Wang, Yi-Zhong; Bex, Peter J.

    2016-01-01

    Purpose Suppression has a key role in the etiology of amblyopia, and contrast-balanced binocular treatment can overcome suppression and improve visual acuity. Quantitative assessment of suppression could have a role in managing amblyopia. We describe a novel eye chart to assess suppression in children. Methods We enrolled 100 children (7–12 years; 63 amblyopic, 25 nonamblyopic with strabismus or anisometropia, 12 controls) in the primary cohort and 22 children (3–6 years; 13 amblyopic, 9 nonamblyopic) in a secondary cohort. Letters were presented on a dichoptic display (5 letters per line). Children wore polarized glasses so that each eye saw a different letter chart. At each position, the identity of the letter and its contrast on each eye's chart differed. Children read 8 lines of letters for each of 3 letter sizes. The contrast balance ratio was the ratio at which 50% of letters seen by the amblyopic eye were reported. Results Amblyopic children had significantly higher contrast balance ratios for all letter sizes compared to nonamblyopic children and controls, requiring 4.6 to 5.6 times more contrast in the amblyopic eye compared to the fellow eye (P < 0.0001). Amblyopic eye visual acuity was correlated with contrast balance ratio (r ranged from 0.49–0.57 for the 3 letter sizes). Change in visual acuity with amblyopia treatment was correlated with change in contrast balance ratio (r ranged from 0.43–0.62 for the 3 letter sizes). Conclusions Severity of suppression can be monitored as part of a routine clinical exam in the management of amblyopia in children. PMID:27784068

  8. Incidence of short-term complications and associated factors after primary trabeculectomy in Chiang Mai University Hospital.

    PubMed

    Leeungurasatien, Thidarat; Khunsongkiet, Preeyanuch; Pathanapitoon, Kassara; Wiwatwongwana, Damrong

    2016-10-01

    To determine the incidence of early postoperative complications and associated factors after primary trabeculectomy in Thai glaucoma patients. This was a retrospective observational study performed in Chiang Mai University Hospital. One hundred and eighteen glaucoma patients participated in the study. All glaucoma patients underwent primary trabeculectomy with mitomycin C (MMC) using fornix-based conjunctival flap technique between December 2011 and May 2013. Surgical complications during the first 3 months of follow-up were recorded, and associated risk factors were analyzed. The incidence of posttrabeculectomy complications was the main outcome measure. One hundred and eighteen eyes of 118 patients were included. Early postoperative complications developed in 55 eyes (56.7%). Complications included hypotony (25 eyes, 27.2%), serous choroidal detachment (CD) (14 eyes, 15.6%), subconjunctival hemorrhage (12 eyes, 13.0%), hyphema (11 eyes, 12.4%), bleb leak (8 eyes, 8.8%), encapsulated bleb (2 eyes, 2.2%), aqueous misdirection (1 eyes, 1.1%), corneal epithelial defect (1 eyes, 1.1%), and overfiltration (1 eyes, 1.1%). There were no reported cases of endophthalmitis or blebitis. Hypotony was associated with serous CD (P = 0.006), and hyphema was associated with neovascular glaucoma (NVG) patients (P = 0.009). NVG was not associated with the increased rate of surgical failure (P = 0.083). The incidence of early complications after first-time trabeculectomy with MMC was high (56.7%) in this Thai clinic setting, but most were transient and self-limited conditions. The correlations between hypotony and CD as well as hyphema and NVG were compatible with the previous studies.

  9. Gonioscopy findings and prevalence of occludable angles in a Burmese population: the Meiktila Eye Study.

    PubMed

    Casson, R J; Newland, H S; Muecke, J; McGovern, S; Abraham, L M; Shein, W K; Selva, D; Aung, T

    2007-07-01

    To determine the prevalence of preglaucomatous angle-closure disease in central Myanmar. A population-based survey of inhabitants >or=40 years in the Meiktila District was carried out; 2481 subjects were identified, 2076 participated and 2060 underwent gonioscopy of at least one eye. Eyes with angles traditionally described as "occludable" were recorded as primary angle-closure suspects (PACS); eyes with PACS and peripheral anterior synechiae (PAS), or an increased intraocular pressure but without primary angle-closure glaucoma, were recorded as primary angle closure (PAC). The prevalence of PACS in at least one eye was 5.7% (95% CI 4.72 to 6.62); prevalence increased with age and was more common in women (p<0.001). The prevalence of PAC in at least one eye was 1.50% (95% CI 1.47 to 1.53). All participants with PAS had at least 90 degrees of closure (range 90-360 degrees). The prevalence of preglaucomatous angle-closure disease (PACS and PAC) in this population was 5.7% and 1.5%, respectively. PACS was more common in women, and its prevalence increased with age.

  10. New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation

    NASA Astrophysics Data System (ADS)

    Irsch, Kristina; Gramatikov, Boris I.; Wu, Yi-Kai; Guyton, David L.

    2014-06-01

    Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.

  11. New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation.

    PubMed

    Irsch, Kristina; Gramatikov, Boris I; Wu, Yi-Kai; Guyton, David L

    2014-06-01

    Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.

  12. Test of the neurolinguistic programming hypothesis that eye-movements relate to processing imagery.

    PubMed

    Wertheim, E H; Habib, C; Cumming, G

    1986-04-01

    Bandler and Grinder's hypothesis that eye-movements reflect sensory processing was examined. 28 volunteers first memorized and then recalled visual, auditory, and kinesthetic stimuli. Changes in eye-positions during recall were videotaped and categorized by two raters into positions hypothesized by Bandler and Grinder's model to represent visual, auditory, and kinesthetic recall. Planned contrast analyses suggested that visual stimulus items, when recalled, elicited significantly more upward eye-positions and stares than auditory and kinesthetic items. Auditory and kinesthetic items, however, did not elicit more changes in eye-position hypothesized by the model to represent auditory and kinesthetic recall, respectively.

  13. Prospective randomized comparison of mitomycin C application in endoscopic and external dacryocystorhinostomy.

    PubMed

    Mudhol, Rekha R; Zingade, N D; Mudhol, R S; Harugop, Anil S; Das, Amal T

    2013-08-01

    The aim of the study is to compare the subjective (relief of symptoms) and objective (endoscopic visualization of ostium patency at the time of syringing) outcomes at the end of two procedures-Endonasal DCR versus External DCR with Mitomycin C and to assess the role of Mitomycin C in maintaining patency of nasolacrimal drainage system. Prospective randomized comparative study was performed. Thirty-five patients were enrolled in each endoscopic and external dacryocystorhinostomy groups with Mitomycin C (MMC) application. The 37 eyes underwent endonasal DCR (28 unilateral primary eyes + 1 bilateral primary eyes + 5 unilateral revision eyes + 1 bilateral revision eye) while 35 eyes underwent external DCR (34 unilateral primary eyes + 1 unilateral revision eye). Mitomycin C 0.2 mg/ml was applied intra-operatively for 5 min to the ostium site at the end of endonasal or external DCR procedure. Objective assessment by syringing at the end of 1 year in the endonasal group showed 35 eyes (94%) were patent, 1 (3%) was partially blocked and 1(3%) was completely blocked; while in external group all 35 eyes (100%) were patent. Endoscopic visualization of the ostium at the time of syringing showed only one eye (3%) in the endonasal group was blocked while all the other eyes in both groups were patent. Both groups had a mean follow-up of 6-36 months. No complications were associated with use of Mitomycin C. In conclusion, intra-operative use of Mitomycin C in both endoscopic DCR and external DCR is safe and effective in increasing the success rate.

  14. Outcomes of Retreatment after Aborted Laser In Situ Keratomileusis due to Flap Complications

    PubMed Central

    Al-Mezaine, Hani S.; Al-Amro, Saleh A.; Al-Fadda, Abdulaziz; Al-Obeidan, Saleh

    2011-01-01

    Purpose: To determine the refractive outcomes and complications of retreatment after aborted primary laser in situ keratomileusis (LASIK) due to flap complications. Materials and Methods: This retrospective study evaluated 50 retreated eyes that had flap complications during primary LASIK at the Eye Consultants Center in Riyadh, Saudi Arabia. Data were analyzed for patients with at least 3 months follow-up post retreatment. Results: Thirty-three eyes of 31 consecutive patients with 3 months follow-up or later post retreatment were included. The primary LASIK was aborted due to incomplete flaps in 22 eyes (66.7%), buttonhole flaps in 7 eyes (21.2%), free partial flaps in 3 eyes (9.1%), and a free complete flap in 1 eye (3.0%). Twenty-two eyes (66.7%) were retreated with LASIK, and 11 eyes (33.3%) were retreated with surface ablation. The mean spherical equivalent (SE) was –0.23 ± 0.72 D, the mean astigmatism was –0.65 ± 0.89 D, and the mean loss of the best corrected visual acuity (BCVA) was 0.78 lines at the final postoperative visit. At the last postoperative visit, 20/30 or better BCVA was achieved in 90.1% of eyes that underwent retreatment with LASIK and in 91% of eyes that were retreated with surface ablation. There was no statistical difference in postoperative SE between eyes retreated with LASIK and eyes retreated with surface ablation (P = 0.610). There was no statistical difference in postoperative BCVA between eyes retreated with LASIK and those retreated with surface ablation (P = 0.756). There were no intraoperative complications and no eyes required a second retreatment. Conclusion: Creation of a flap after a previous intraoperative flap complication was not associated with any complications. The refractive outcomes of retreatment with LASIK or surface ablation were comparable and reasonably favorable. PMID:21887080

  15. Outcome of in-the-bag implanted square-edge polymethyl methacrylate intraocular lenses with and without primary posterior capsulotomy in pediatric traumatic cataract

    PubMed Central

    Verma, Neelam; Ram, Jagat; Sukhija, Jaspreet; Pandav, Surinder S.; Gupta, Amit

    2011-01-01

    Purpose: To study the outcome of in-the-bag implanted square-edge polymethyl methacrylate (PMMA) intraocular lenses (IOL) with and without primary posterior capsulotomy in pediatric traumatic cataract. Materials and Methods: The study was undertaken in a tertiary care center. Thirty eyes of 30 children ranging in age from 4 to 16 years with traumatic cataract which underwent cataract extraction with capsular bag implantation of IOL were prospectively evaluated. Group A included 15 eyes of 15 children where primary posterior capsulotomy (PPC) and anterior vitrectomy with capsular bag implantation of square-edge PMMA IOL (Aurolab SQ3602, Madurai, Tamil Nadu, India) was performed. Group B comprised 15 eyes of 15 children in which the posterior capsule was left intact. Postoperative visual acuity, visual axis opacification (VAO) and possible complications were analyzed. Results: Best corrected visual acuity (BCVA) of 20/40 or better was achieved in 12 of 15 eyes in both groups. Amblyopia was the cause of no improvement in visual acuity in the remaining eyes. Visual axis opacification was significantly high in Group B as compared to Group A (P=0.001). Postoperative fibrinous uveitis occurred in most of the eyes in both groups. Pupillary capture was observed in one eye in each group. Conclusion: Primary posterior capsulotomy and anterior vitrectomy with capsular bag implantation of square-edge PMMA significantly helps to maintain a clear visual axis in children with traumatic cataract. PMID:21836338

  16. Persistent hyperplastic primary vitreous in transgenic mice expressing IE180 of the pseudorabies virus.

    PubMed

    Taharaguchi, Satoshi; Yoshida, Kazuhiko; Tomioka, Yukiko; Yoshino, Saori; Uede, Toshimitsu; Ono, Etsuro

    2005-05-01

    Pseudorabies virus (PRV), a representative member of the alpha-herpesvirus family, causes nervous symptoms and ocular lesions, such as keratoconjunctivitis and retinal degeneration in piglets. The immediate-early protein IE180 of the PRV is known to be essential, not only in viral gene expression, but also in the cellular gene expression in host cells. The purpose of this study was to examine the effect of IE180 on the development of the mouse eye, by using transgenic technology. Transgenic mice expressing IE180 were generated and their eyes analyzed by histology, immunocytochemistry, and the bromodeoxyuridine cell proliferation assay. A fibrovascular retrolental tissue analogous to persistent hyperplastic primary vitreous (PHPV) in humans was observed in a transgenic mouse line expressing IE180. The gross anatomy of the eye showed white pupils. Analysis of hematoxylin and eosin-stained sections revealed that the retrolental tissue adhered to the neuroretina, the inner nuclear and ganglion cell layers were disorganized, and rosettelike arrangements of dysplastic photoreceptor cells were present. Bromodeoxyuridine-positive cells were detected in the retrolental tissues of postnatal day (P)1, P7, and P14 mice. The retrolental mass in the P7 transgenic mouse was composed of melanocytes and endothelial cells, which were detected by a cocktail of antibodies against endoglin, CD31, and VEGF receptor-2. The observation that the eye disease in transgenic mice is similar to that in PHPV in humans raises the possibility that expression of the immediate-early gene of alpha-herpesviruses may contribute to PHPV.

  17. Red eyes and red-flags: improving ophthalmic assessment and referral in primary care.

    PubMed

    Kilduff, Caroline; Lois, Charis

    2016-01-01

    Up to five percent of primary care consultations are eye-related, yet 96% of General Practitioners (GPs) do not undergo postgraduate ophthalmology training. Most do not feel assured performing eye assessments. Some red eye conditions can become sight threatening, and often exhibit red-flag features. These features include moderate pain, photophobia, reduced visual acuity (VA), eye-trauma, or unilateral marked redness. The aim of this project was to improve primary care assessment and referral of patients presenting with red-flag features based on the NICE 'Red Eye' Clinical Knowledge Summary recommendations. Data was collected retrospectively from 139 red eye consultations. A practice meeting highlighted poor awareness of red-flag features, low confidence levels in eye assessments, and time-constraints during appointments. Interventions were based on feedback from staff. These included a primary care teaching session on red-flag features, a VA measurement tutorial, and provision of a red eye toolkit, including VA equipment, to each consultation room. At baseline, each patient had on average 0.9 red-flag features assessed. Only 36.0% (9/25) of patients with red-flag features were appropriately referred to same-day ophthalmology services. Following two improvement cycles, a significant improvement was seen in almost every parameter. On average, each patient had 2.7 red-flag features assessed (vs 0.9, p<0.001). VA was assessed in 55.6% of consultations (vs 7.9%, p<0.001), pain was quantified in 81.5% (vs 20.9%, p=0.005), eye-trauma or foreign-body (51.8% vs 8.6%, p<0.001), extent of redness was documented in 66.7% (vs 14.4%, p<0.001). Only photophobia remained poorly assessed (18.5% vs 14.4%, p=0.75). Following this, 75.0% (6/8) of patients were appropriately referred. This project reflected the literature regarding low confidence and inexperience amongst GPs when faced with ophthalmic conditions. Improvements in education are required to ensure accurate assessments can be undertaken in a time-constrained environment.

  18. Coordinated Flexibility: How Initial Gaze Position Modulates Eye-Hand Coordination and Reaching

    ERIC Educational Resources Information Center

    Adam, Jos J.; Buetti, Simona; Kerzel, Dirk

    2012-01-01

    Reaching to targets in space requires the coordination of eye and hand movements. In two experiments, we recorded eye and hand kinematics to examine the role of gaze position at target onset on eye-hand coordination and reaching performance. Experiment 1 showed that with eyes and hand aligned on the same peripheral start location, time lags…

  19. Symmetry of oculomotor burst neuron coordinates about Listing's plane.

    PubMed

    Crawford, J D; Vilis, T

    1992-08-01

    1. The purpose of this investigation was to determine the axes of eye rotation generated by oculomotor burst neuron populations and the coordinate system that they collectively define. In particular, we asked if such coordinates might be related to constraints in the emergent behavior, i.e., Listing's law for saccades. 2. The mesencephalic rostral interstitial nucleus of the medial longitudinal fasciculus (riMLF) was identified in four monkeys with the use of single-unit recording, and then explored with the use of electrical microstimulation and pharmacological inactivation with the inhibitory gamma-aminobutyric acid (GABA) agonist muscimol. Three-dimensional (3-D) eye positions and velocities were recorded in one or both eyes while alert animals made eye movements in response to visual stimuli and head rotation. 3. Unilateral stimulation of the riMLF (20 microA, 200 Hz, 300-600 ms) produced conjugate, constant velocity eye rotations, which then stopped abruptly and held their final positions. This is expected if the riMLF produces phasic signals upstream from the oculomotor integrator. 4. Units that burst before upward or downward saccades were recorded intermingled in each side of the riMLF. Unilateral stimulation of the same riMLF sites produced eye rotations about primarily torsional axes, clockwise (CW) during right riMLF stimulation and counterclockwise (CCW) during left stimulation. Only small and inconsistent vertical components were observed, supporting the view that the riMLF carries intermingled up and down signals. 5. The torsional axes of eye rotation produced by riMLF stimulation did not correlate to external anatomic landmarks. Instead, stimulation axes from both riMLF sides aligned with the primary gaze direction orthogonal to Listing's plane of eye positions recorded during saccades. 6. Injection of muscimol into one side of the riMLF produced a conjugate deficit in saccades and quick phases, including a 50% reduction in all vertical velocities and complete loss of one torsional direction. CW was lost after right riMLF inactivation, and CCW was lost after left inactivation. 7. The plane that separated the intact torsional axes from the missing axes correlated with the orientation of Listing's plane. Thus, during left or right riMLF inactivation, the vertical axes of intact horizontal saccades were abnormally aligned with Listing's plane. The orientation of these axes was not correlated with external anatomic landmarks. 8. As suggested by their alignment with Listing's plane, the intact vertical axes of horizontal saccades following riMLF inactivation were orthogonal to torsional riMLF stimulation axes.(ABSTRACT TRUNCATED AT 400 WORDS)

  20. MR-eyetracker: a new method for eye movement recording in functional magnetic resonance imaging.

    PubMed

    Kimmig, H; Greenlee, M W; Huethe, F; Mergner, T

    1999-06-01

    We present a method for recording saccadic and pursuit eye movements in the magnetic resonance tomograph designed for visual functional magnetic resonance imaging (fMRI) experiments. To reliably classify brain areas as pursuit or saccade related it is important to carefully measure the actual eye movements. For this purpose, infrared light, created outside the scanner by light-emitting diodes (LEDs), is guided via optic fibers into the head coil and onto the eye of the subject. Two additional fiber optical cables pick up the light reflected by the iris. The illuminating and detecting cables are mounted in a plastic eyepiece that is manually lowered to the level of the eye. By means of differential amplification, we obtain a signal that covaries with the horizontal position of the eye. Calibration of eye position within the scanner yields an estimate of eye position with a resolution of 0.2 degrees at a sampling rate of 1000 Hz. Experiments are presented that employ echoplanar imaging with 12 image planes through visual, parietal and frontal cortex while subjects performed saccadic and pursuit eye movements. The distribution of BOLD (blood oxygen level dependent) responses is shown to depend on the type of eye movement performed. Our method yields high temporal and spatial resolution of the horizontal component of eye movements during fMRI scanning. Since the signal is purely optical, there is no interaction between the eye movement signals and the echoplanar images. This reasonably priced eye tracker can be used to control eye position and monitor eye movements during fMRI.

  1. Self-bending of optical waveguides in a dry photosensitive medium

    NASA Astrophysics Data System (ADS)

    Malallah, Ra'ed; Wan, Min; Muniraj, Inbarasan; Cassidy, Derek; Sheridan, John T.

    2018-03-01

    Optical waveguide trajectories formed in an AA/PVA a photopolymer material photosensitive at 532 nm are examined. The transmission of light by this materials is discussed. The bending and arching of the waveguides which occur are investigated. The prediction of our model are shown to agree with the observed of trajectories. The largest index changes taking place at any time during the exposure, i.e. during SWW formation are found at the positions where the largest light intensity is present. Typically, such as maxima exist close to the input face at the location of the Primary Eye or at the location of the Secondary Eyes deeper with in the material. All photosensitive materials have a maximum saturation value of refractive index change that it is possible to induce, which is also discussed.

  2. Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations.

    PubMed

    Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T

    1999-05-01

    Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the VOR does not become apparent until 47 ms after the onset of the stimulus. In contrast, the response to active high acceleration stimuli shows eye position-dependence from within 5 ms of the onset of the stimulus. A model using a VOR-Listing's law compromise strategy did not accurately predict the patterns observed in the data, raising questions about how the eye position-dependence of the VOR is generated. We suggest, in view of recent findings, that the phenomenon could arise due to the effects of fibromuscular pulleys on the functional pulling directions of the rectus muscles.

  3. Effect of Education Sessions of a Structured School Eye Screening Programme on Indian Schoolteachers' Knowledge and Responsibility for Children's Eye Health

    ERIC Educational Resources Information Center

    Thummalapalli, Rohit; Williams, Jachin D.; Khoshnood, Kaveh; Salchow, Daniel J.; Forster, Susan H.

    2013-01-01

    Objective: To evaluate the effect of education sessions on Indian schoolteacher awareness of childhood eye health issues, responsibility for children's eye health, and successful participation in a teacher-led eye screening health intervention programme in primary schools aimed at addressing avoidable childhood blindness in India. Design:…

  4. Critical Involvement of Extracellular ATP Acting on P2RX7 Purinergic Receptors in Photoreceptor Cell Death

    PubMed Central

    Notomi, Shoji; Hisatomi, Toshio; Kanemaru, Takaaki; Takeda, Atsunobu; Ikeda, Yasuhiro; Enaida, Hiroshi; Kroemer, Guido; Ishibashi, Tatsuro

    2011-01-01

    Stressed cells release ATP, which participates in neurodegenerative processes through the specific ligation of P2RX7 purinergic receptors. Here, we demonstrate that extracellular ATP and the more specific P2RX7 agonist, 2′- and 3′-O-(4-benzoylbenzoyl)-ATP, both induce photoreceptor cell death when added to primary retinal cell cultures or when injected into the eyes from wild-type mice, but not into the eyes from P2RX7−/− mice. Photoreceptor cell death was accompanied by the activation of caspase-8 and -9, translocation of apoptosis-inducing factor from mitochondria to nuclei, and TUNEL-detectable chromatin fragmentation. All hallmarks of photoreceptor apoptosis were prevented by premedication or co-application of Brilliant Blue G, a selective P2RX7 antagonist that is already approved for the staining of internal limiting membranes during ocular surgery. ATP release is up-regulated by nutrient starvation in primary retinal cell cultures and seems to be an initializing event that triggers primary and/or secondary cell death via the positive feedback loop on P2RX7. Our results encourage the potential application of Brilliant Blue G as a novel neuroprotective agent in retinal diseases or similar neurodegenerative pathologies linked to excessive extracellular ATP. PMID:21983632

  5. Ocular surface changes in thyroid eye disease.

    PubMed

    Ismailova, Dilyara S; Fedorov, Anatoly A; Grusha, Yaroslav O

    2013-04-01

    To study the incidence and risk factors of ocular surface damage in thyroid eye disease (TED) and to determine histological changes underlying positive vital staining in this condition. Forty-six patients (92 eyes) with TED were included in this study. Routine ophthalmologic examination, Schirmer test I, vital staining and corneal sensitivity were performed. Fifteen patients with positive vital staining underwent impression cytology and incisional biopsy. Positive vital staining with lissamine green was observed in 56 eyes (60.9%), 30 patients (65.2%). The average degree of staining was 4.57 ± 0.44 (National Eye Institute Workshop grading system). Severe dry eye syndrome was found in 16%. The following histological changes of conjunctiva were revealed: significant epithelial dystrophy with cell polymorphism, goblet cells loss, excessive desquamation and epithelial keratinization with local leukocytic infiltration of substantia propria. According to our results dry eye syndrome is present in 65.2% of patients (60.9% eyes) with TED. Significant risk factors of ocular surface damage in TED were exophthalmos, lagophthalmos, palpebral fissure height and lower lid retraction. Positive conjunctival staining results from punctuate epithelial erosions and excessive desquamation of superficial cells. Histopathologic changes detected in conjunctiva consistent with dry eye and are not specific for TED.

  6. Iridotomy to slow progression of angle-closure glaucoma

    PubMed Central

    Le, Jimmy T; Rouse, Benjamin; Gazzard, Gus

    2016-01-01

    This is the protocol for a review and there is no abstract. The objectives are as follows: The primary objective is to assess the role of iridotomy-compared with observation-in the prevention of visual field loss for individuals who have primary angle closure or primary angle-closure glaucoma in at least one eye. We will also examine the role of iridotomy in the prevention of elevated intraocular pressure (IOP) in individuals with narrow angles (primary angle-closure suspect) in at least one eye. PMID:27551238

  7. Gonioscopy findings and prevalence of occludable angles in a Burmese population: the Meiktila Eye Study

    PubMed Central

    Casson, R J; Newland, H S; Muecke, J; McGovern, S; Abraham, L M; Shein, W K; Selva, D; Aung, T

    2007-01-01

    Aim To determine the prevalence of preglaucomatous angle‐closure disease in central Myanmar. Methods A population‐based survey of inhabitants ⩾40 years in the Meiktila District was carried out; 2481 subjects were identified, 2076 participated and 2060 underwent gonioscopy of at least one eye. Eyes with angles traditionally described as “occludable” were recorded as primary angle‐closure suspects (PACS); eyes with PACS and peripheral anterior synechiae (PAS), or an increased intraocular pressure but without primary angle‐closure glaucoma, were recorded as primary angle closure (PAC). Results The prevalence of PACS in at least one eye was 5.7% (95% CI 4.72 to 6.62); prevalence increased with age and was more common in women (p<0.001). The prevalence of PAC in at least one eye was 1.50% (95% CI 1.47 to 1.53). All participants with PAS had at least 90° of closure (range 90–360°). Conclusion The prevalence of preglaucomatous angle‐closure disease (PACS and PAC) in this population was 5.7% and 1.5%, respectively. PACS was more common in women, and its prevalence increased with age. PMID:17576708

  8. Compensating For Movement Of Eye In Laser Surgery

    NASA Technical Reports Server (NTRS)

    Juday, Richard D.

    1991-01-01

    Conceptual system for laser surgery of retina includes subsystem that tracks position of retina. Tracking signal used to control galvanometer-driven mirrors keeping laser aimed at desired spot on retina as eye moves. Alternatively or additionally, indication of position used to prevent firing of laser when eye moved too far from proper aiming position.

  9. Expansion of visual space during optokinetic afternystagmus (OKAN).

    PubMed

    Kaminiarz, André; Krekelberg, Bart; Bremmer, Frank

    2008-05-01

    The mechanisms underlying visual perceptual stability are usually investigated using voluntary eye movements. In such studies, errors in perceptual stability during saccades and pursuit are commonly interpreted as mismatches between actual eye position and eye-position signals in the brain. The generality of this interpretation could in principle be tested by investigating spatial localization during reflexive eye movements whose kinematics are very similar to those of voluntary eye movements. Accordingly, in this study, we determined mislocalization of flashed visual targets during optokinetic afternystagmus (OKAN). These eye movements are quite unique in that they occur in complete darkness and are generated by subcortical control mechanisms. We found that during horizontal OKAN slow phases, subjects mislocalize targets away from the fovea in the horizontal direction. This corresponds to a perceived expansion of visual space and is unlike mislocalization found for any other voluntary or reflexive eye movement. Around the OKAN fast phases, we found a bias in the direction of the fast phase prior to its onset and opposite to the fast-phase direction thereafter. Such a biphasic modulation has also been reported in the temporal vicinity of saccades and during optokinetic nystagmus (OKN). A direct comparison, however, showed that the modulation during OKAN was much larger and occurred earlier relative to fast-phase onset than during OKN. A simple mismatch between the current eye position and the eye-position signal in the brain is unlikely to explain such disparate results across similar eye movements. Instead, these data support the view that mislocalization arises from errors in eye-centered position information.

  10. Sunglasses with thick temples and frame constrict temporal visual field.

    PubMed

    Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric

    2013-12-01

    Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p < 0.05 were considered significant. A glare test was done using a surgical lighting system pointed at the eye(s) at different incidence angles. No significant "base visual field" or "eye motion visual field" surface area variations were noted when comparing tests done without glasses and with the "thin sunglasses." In contrast, a 22% "eye motion visual field" surface area decrease (p < 0.001) was noted when comparing tests done without glasses and with "thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p < 0.001). All subjects reported less lateral glare with the "thick sunglasses" than with the "thin sunglasses" (p < 0.001). The better protection from lateral glare offered by "thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.

  11. Photorefractor ocular screening system

    NASA Technical Reports Server (NTRS)

    Richardson, John R. (Inventor); Kerr, Joseph H. (Inventor)

    1987-01-01

    A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.

  12. Controlled five-year follow-up study of laser trabeculoplasty as primary therapy for open-angle glaucoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuulonen, A.; Niva, A.K.; Alanko, H.I.

    1987-10-15

    We followed up 32 eyes of 32 patients with early glaucoma (22 with capsular glaucoma and ten with simple glaucoma) who received laser trabeculoplasty as a primary therapy. These eyes were compared with a matched control group of 32 eyes treated with medication initially. The success rate (intraocular pressure below 22 mm Hg with laser alone or medication alone) at five years was 50% (16 of 32 eyes) in the laser-treated group and 22% (seven of 32 eyes) in the control group (P less than .02). The control group required more modifications of their therapy to control intraocular pressure. Themore » neuroretinal rim area in the control eyes decreased 2.5 times as much as in the laser group (P = .017). Changes in the Friedmann visual fields did not differ significantly between the two groups.« less

  13. Effect of using a combination of lid wipes, eye drops, and omega-3 supplements on meibomian gland functionality in patients with lipid deficient/evaporative dry eye.

    PubMed

    Korb, Donald R; Blackie, Caroline A; Finnemore, Victor M; Douglass, Teresa

    2015-04-01

    The aim of this study was to assess the efficacy of using a combination treatment approach consisting of lipid emulsion eye drops, eyelid cleansing wipes, and omega-3 vitamin supplements compared with warm compresses in improving meibomian gland functionality in patients with lipid-deficient/evaporative dry eye disease (LDDE). This single-center, open-label, investigator-masked, randomized study enrolled patients aged ≥18 years, clinically diagnosed with LDDE defined as having ≤6 functional meibomian glands [meibomian gland yielding liquid secretion (MGYLS)] and positive for dry eye symptoms at screening. Patients were randomized to receive either the combination treatment (lipid emulsion eye drops, omega-3 supplements, and lid hygiene with eyelid wipes) or to apply warm, wet compresses once daily, 8 minutes per day, for 3 months. Meibomian gland functionality (number of MGYLS; primary outcome) and patient-reported subjective assessments (SPEED and OSDI questionnaires; secondary outcomes) were evaluated. Adverse events (AEs) and visual acuity were assessed as safety endpoints. Mean patient age was 41.7 years (n = 26; n = 13 per group). Mean ± SD number of MGYLS was not statistically significantly different between groups at baseline (combination treatment, 3.5 ± 1.5; warm compresses, 4.2 ± 1.4, P > 0.5), and was significantly greater with combination treatment versus warm compresses after 3 months of treatment (9.3 ± 2.7 vs. 4.7 ± 2.3; P = 0.006). Dry eye symptoms were significantly improved in both groups at all follow-up visits. Two AEs unrelated to treatment were reported; the BCVA was unchanged from baseline in both groups. The combination treatment regimen resulted in significant improvement in meibomian gland functionality and dry eye symptoms. No safety issues were observed.

  14. EFFECTS OF TOPICAL CORTICOSTEROID ADMINISTRATION ON INTRAOCULAR PRESSURE IN NORMAL AND GLAUCOMATOUS CATS

    PubMed Central

    Gosling, Allyson A; Kiland, Julie A; Rutkowski, Lauren E; Hoefs, Adam; Ellinwood, N Matthew; McLellan, Gillian J

    2016-01-01

    Objective to determine the effect of topical corticosteroid (CCS) therapy on intraocular pressure (IOP) in normal cats and cats with primary feline congenital glaucoma (FCG). Animals studied 5 normal and 11 FCG cats were studied in 2 cohorts. Procedures IOP was measured by a single, masked observer, once daily 3–5 days/week throughout the course of CCS treatment and for up to 11 days after treatment discontinuation. One eye per cat was randomly assigned for treatment twice daily with CCS; Balanced salt solution (BSS) applied to the contralateral eye, served as a control. Differences between eyes and between weeks of the study period were calculated for each cat. A positive response to CCS was defined as a consistent >15% or >25% higher IOP in the treated relative to control eye in normal and FCG cats, respectively. Results 8/11 FCG cats responded to topical CCS after 1–5 weeks of treatment with an increase in IOP relative to the untreated eye (maximum IOP discrepancy of 56 mmHg). 2/5 normal cats responded to topical CCS with appreciable but clinically unimportant increase in IOP in the treated eye (maximum IOP discrepancy of 6.4 mmHg). Conclusions our data indicate that the incidence of steroid induced IOP elevation in cats is lower than previously published feline studies suggest. Cats with pre-existing compromise in aqueous humor outflow may show a greater, clinically relevant response to topical CCS than normal cats. PMID:26876736

  15. Human rather than ape-like orbital morphology allows much greater lateral visual field expansion with eye abduction

    PubMed Central

    Denion, Eric; Hitier, Martin; Levieil, Eric; Mouriaux, Frédéric

    2015-01-01

    While convergent, the human orbit differs from that of non-human apes in that its lateral orbital margin is significantly more rearward. This rearward position does not obstruct the additional visual field gained through eye motion. This additional visual field is therefore considered to be wider in humans than in non-human apes. A mathematical model was designed to quantify this difference. The mathematical model is based on published computed tomography data in the human neuro-ocular plane (NOP) and on additional anatomical data from 100 human skulls and 120 non-human ape skulls (30 gibbons; 30 chimpanzees / bonobos; 30 orangutans; 30 gorillas). It is used to calculate temporal visual field eccentricity values in the NOP first in the primary position of gaze then for any eyeball rotation value in abduction up to 45° and any lateral orbital margin position between 85° and 115° relative to the sagittal plane. By varying the lateral orbital margin position, the human orbit can be made “non-human ape-like”. In the Pan-like orbit, the orbital margin position (98.7°) was closest to the human orbit (107.1°). This modest 8.4° difference resulted in a large 21.1° difference in maximum lateral visual field eccentricity with eyeball abduction (Pan-like: 115°; human: 136.1°). PMID:26190625

  16. The Dorsal Visual System Predicts Future and Remembers Past Eye Position

    PubMed Central

    Morris, Adam P.; Bremmer, Frank; Krekelberg, Bart

    2016-01-01

    Eye movements are essential to primate vision but introduce potentially disruptive displacements of the retinal image. To maintain stable vision, the brain is thought to rely on neurons that carry both visual signals and information about the current direction of gaze in their firing rates. We have shown previously that these neurons provide an accurate representation of eye position during fixation, but whether they are updated fast enough during saccadic eye movements to support real-time vision remains controversial. Here we show that not only do these neurons carry a fast and accurate eye-position signal, but also that they support in parallel a range of time-lagged variants, including predictive and post dictive signals. We recorded extracellular activity in four areas of the macaque dorsal visual cortex during a saccade task, including the lateral and ventral intraparietal areas (LIP, VIP), and the middle temporal (MT) and medial superior temporal (MST) areas. As reported previously, neurons showed tonic eye-position-related activity during fixation. In addition, they showed a variety of transient changes in activity around the time of saccades, including relative suppression, enhancement, and pre-saccadic bursts for one saccade direction over another. We show that a hypothetical neuron that pools this rich population activity through a weighted sum can produce an output that mimics the true spatiotemporal dynamics of the eye. Further, with different pooling weights, this downstream eye position signal (EPS) could be updated long before (<100 ms) or after (<200 ms) an eye movement. The results suggest a flexible coding scheme in which downstream computations have access to past, current, and future eye positions simultaneously, providing a basis for visual stability and delay-free visually-guided behavior. PMID:26941617

  17. Effects of mitomycin C on the expression of chymase and mast cells in the conjunctival scar of a monkey trabeculectomy model

    PubMed Central

    Okada, Kouhei; Takai, Shinji; Jin, Denan; Ishida, Osamu; Fukmoto, Masanori; Oku, Hidehiro; Miyazaki, Mizuo; Ikeda, Tsunehiko

    2009-01-01

    Purpose To determine the effects of mitomycin C (MMC) on the expression of chymase and mast cells in the conjunctival scar after trabeculectomy. Methods Ten eyes of five monkeys were used. Three eyes underwent trabeculectomy with MMC (MMC-treated), four eyes had trabeculectomy without MMC (placebo-treated), and three eyes served as control eyes. Intraocular pressure was measured before and three weeks after surgery. The scores of the degree of conjunctival adhesion were evaluated. Immunohistochemistry was used to analyze the densities of proliferative cell nuclear antigen-positive cells, chymase-positive cells, and mast cells. The ratio of collagen fiber areas to conjunctival and scleral lesions was analyzed by Mallory-Azan staining. Results After trabeculectomy, the intraocular pressure reduction of MMC-treated eyes was significantly different from placebo-treated and control eyes (p=0.032, 0.035). The adhesion score of MMC-treated eyes was also significantly lower than that of placebo-treated eyes (p=0.034). Densities of proliferative cell nuclear antigen-positive cells, chymase-positive cells, and areas of collagen fiber in conjunctival and scleral lesions were significantly decreased in MMC-treated eyes, compared with placebo-treated eyes (p=0.034, 0.034, 0.049, respectively). There was a tendency for the density of mast cells to be suppressed in MMC-treated eyes (p=0.157). Conclusions Chymase might be involved in one of the mechanisms by which MMC suppresses scar formation after trabeculectomy. PMID:19844588

  18. Gravity modulates Listing's plane orientation during both pursuit and saccades

    NASA Technical Reports Server (NTRS)

    Hess, Bernhard J M.; Angelaki, Dora E.

    2003-01-01

    Previous studies have shown that the spatial organization of all eye orientations during visually guided saccadic eye movements (Listing's plane) varies systematically as a function of static and dynamic head orientation in space. Here we tested if a similar organization also applies to the spatial orientation of eye positions during smooth pursuit eye movements. Specifically, we characterized the three-dimensional distribution of eye positions during horizontal and vertical pursuit (0.1 Hz, +/-15 degrees and 0.5 Hz, +/-8 degrees) at different eccentricities and elevations while rhesus monkeys were sitting upright or being statically tilted in different roll and pitch positions. We found that the spatial organization of eye positions during smooth pursuit depends on static orientation in space, similarly as during visually guided saccades and fixations. In support of recent modeling studies, these results are consistent with a role of gravity on defining the parameters of Listing's law.

  19. Anatomic and visual outcomes of 23-G vitrectomy without scleral buckling for primary rhegmatogenous retinal detachment.

    PubMed

    Figueroa, Marta S; Contreras, Inés; Noval, Susana

    2013-01-01

    To evaluate the anatomic success rate, visual acuity (VA) changes, and complications of 23-G vitrectomy without associated scleral procedures for the treatment of primary rhegmatogenous retinal detachment (PRRD). 
 Patients diagnosed with PRRD were considered for inclusion. Patients with evidence of proliferative vitreoretinopathy or coexisting ocular pathologies were excluded. Surgery consisted of 23-G vitrectomy with endolaser photocoagulation of retinal breaks and fluid-air-gas (12% C3F8) exchange. Minimum follow-up was 3 months. 
 A total of 133 eyes of 118 patients were included. Fifty eyes were phakic and 83 pseudophakic. Mean time from diagnosis to surgery was 6.9 days (range 1-40). Mean VA improved significantly from 20/50 (range: hand movements to 20/20) to 20/30 (range: counting fingers to 20/16), with no statistically significant differences between phakic and pseudophakic eyes (p = 0.233). Visual acuity improved to 20/40 or better in 104 eyes (78.2%). A redetachment developed in 5 eyes (3.8%), so the primary anatomic success rate was 96.2%. Four eyes required a second surgical procedure and one eye a third to achieve retinal reattachment. Cataract progression in phakic eyes made cataract surgery necessary within 1 year of vitrectomy in 12/50 (24%) eyes. Subretinal perfluoro-N-octane (PFO) was detected in 6 eyes (4.5%). 
 Twenty-three--gauge vitrectomy without scleral buckling seems to be an effective technique for the treatment of PRRD without proliferative vitreoretinopathy. The high anatomic success rate was comparable to that previously described with 20 G and scleral buckling. Complications were similar to those described for 20-G vitrectomy, except for retained subretinal PFO, which has a higher rate.

  20. Gonioscopy in the dog: inter-examiner variability and the search for a grading scheme.

    PubMed

    Oliver, J A C; Cottrell, B C; Newton, J R; Mellersh, C S

    2017-11-01

    To investigate inter-examiner variability in gonioscopic evaluation of pectinate ligament abnormality in dogs and to assess level of inter-examiner agreement for four different gonioscopy grading schemes. Two examiners performed gonioscopy in 98 eyes of 49 Welsh springer spaniel dogs and estimated the percentage circumference of iridocorneal angle affected by pectinate ligament abnormality to the nearest 5%. Percentage scores assigned to each eye by the two examiners were compared. Inter-examiner agreement was assessed following assignment of the percentage scores to each of four grading schemes by Cohen's kappa statistic. There was a strong positive correlation between the results of the two examiners (R=0·91). In general, Examiner 1 scored individual eyes higher than Examiner 2, especially for eyes in which both examiners diagnosed pectinate ligament abnormality. A "good" level of agreement could only be achieved with a gonioscopy grading scheme of no more than three categories and with a relatively large intermediate bandwidth (κ=0·68). A three-tiered grading scheme might represent an improvement on hereditary eye disease schemes which simply classify dogs to be either "affected" or "unaffected" for pectinate ligament abnormality. However, the large intermediate bandwidth of this scheme would only allow for the additional detection of those dogs with marked progression of pectinate ligament abnormality which would be considered most at risk of primary closed-angle glaucoma. © 2017 British Small Animal Veterinary Association.

  1. Eye Injuries Among Primary School Children in Enugu, Nigeria: Rural vs Urban.

    PubMed

    Okpala, Nonso Ejikeme; Umeh, Rich Enujioke; Onwasigwe, Ernest Nnemeka

    2015-01-01

    A cross-sectional survey of the prevalence of eye injuries among primary school children in two noncontiguous local government areas of Enugu State of Nigeria was undertaken. One of the local government areas was urban, while the other one was rural. Children who were <15 years in two randomly selected primary schools in the urban area and three randomly selected schools in the rural area were interviewed and examined with Snellen chart, pen torch, head loupe, and direct ophthalmoscope. The findings were recorded using a semi-structured questionnaire and the World Health Organization Programme for Prevention of Blindness (WHO/PBL) eye examination form. Training on visual acuity measurement was done for each of the class teachers. A total of 1,236 children <15 years of age were studied and analyzed. Slightly more females, 652 (52.8%), than males, 584 (47.2%), constituted the sample population giving a female/male ratio of 1.1:1. A total of 98 (7.93%) children had evidence of injury to the eye or its adnexa. Eyelid scar was the commonest (5.34%) followed by eyebrow scar (2.10%). Canthal scar was the next (0.32%). Two girls had monocular blindness from eye trauma (0.16%). One had leucoma, while the other had a dislocated lens. All the monocular blind children of this study were from the urban area. The home was the commonest environment for an eye injury (69.39%) followed by the school (20.41%). The farm was next in frequency (7.14%), especially among boys in the rural area. The church and the road/street constituted the remainder. Regarding persons causing the injury, the child's playmate was the commonest (55.10%) followed by self (27.55%). Parents and guardians were the next (9.18%). These were injuries associated with corporal punishment. Corporal punishment-related eye injury, according to this study, appears to be common in the rural area and affects boys predominantly. Other human intermediary agents that cause an eye injury include passersby (2.04%), RTA (2.04%), siblings (2.04%), and others (1.02%). The primary agents that caused an eye injury were sticks/wood, 29 (29.60%); stone, 21 (21.43%); pieces of metal, 19 (19.39%); fall, 10 (10.20%); fight/fist blow, 9 (9.918%); plastic, 2 (2.04%); fingernails, 2 (2.04%); farm tools/fruits, 2 (2.04%); and RTA, glass, and headbutt, each 1.02%. Farm implements/fruits as well as fingernails appear to be fairly common primary agents that cause an eye injury in the rural Enugu, Nigeria. In terms of prevalence, there was no significant difference between the urban and rural areas. The findings from this study showed a high prevalence of eye injury among primary school children. In terms of treatment, 58.16% of the children with an eye injury had no form of treatment for it. The children from this study with monocular blindness did not receive adequate medical treatment. Treatment of an eye injury, according to this study, was sought from chemists (19.39%), at hospital/health centers (16.33%), at home (3.06%), and from traditional healers (3.06%). The persons who treated an eye injury, as observed from this study, were doctors (14.29%), nurses (4.08%), chemists (17.35%), and traditional healers and fathers (3.06% each). The frequency of noninjury-related diagnosis made in this study was refractive error, 4.85%; allergic conjunctivitis, 1.94%; oculocutaneous albinism, 0.24%; prepapillary vascular loops, 0.40%; and then ptosis, exotropia, stye, corneal opacity, and retinitis pigmentosa, 0.08% each. The annual incidence of an eye injury according to this study was 3.48%. The majority of the causes of an eye injury, as per this study, were preventable. Appropriate promotion of preventive eye care among children may go a long way in reducing the burden of blindness from eye injuries.

  2. Eye Injuries Among Primary School Children in Enugu, Nigeria: Rural vs Urban

    PubMed Central

    Okpala, Nonso Ejikeme; Umeh, Rich Enujioke; Onwasigwe, Ernest Nnemeka

    2015-01-01

    A cross-sectional survey of the prevalence of eye injuries among primary school children in two noncontiguous local government areas of Enugu State of Nigeria was undertaken. One of the local government areas was urban, while the other one was rural. Children who were <15 years in two randomly selected primary schools in the urban area and three randomly selected schools in the rural area were interviewed and examined with Snellen chart, pen torch, head loupe, and direct ophthalmoscope. The findings were recorded using a semi-structured questionnaire and the World Health Organization Programme for Prevention of Blindness (WHO/PBL) eye examination form. Training on visual acuity measurement was done for each of the class teachers. A total of 1,236 children <15 years of age were studied and analyzed. Slightly more females, 652 (52.8%), than males, 584 (47.2%), constituted the sample population giving a female/male ratio of 1.1:1. A total of 98 (7.93%) children had evidence of injury to the eye or its adnexa. Eyelid scar was the commonest (5.34%) followed by eyebrow scar (2.10%). Canthal scar was the next (0.32%). Two girls had monocular blindness from eye trauma (0.16%). One had leucoma, while the other had a dislocated lens. All the monocular blind children of this study were from the urban area. The home was the commonest environment for an eye injury (69.39%) followed by the school (20.41%). The farm was next in frequency (7.14%), especially among boys in the rural area. The church and the road/street constituted the remainder. Regarding persons causing the injury, the child’s playmate was the commonest (55.10%) followed by self (27.55%). Parents and guardians were the next (9.18%). These were injuries associated with corporal punishment. Corporal punishment-related eye injury, according to this study, appears to be common in the rural area and affects boys predominantly. Other human intermediary agents that cause an eye injury include passersby (2.04%), RTA (2.04%), siblings (2.04%), and others (1.02%). The primary agents that caused an eye injury were sticks/wood, 29 (29.60%); stone, 21 (21.43%); pieces of metal, 19 (19.39%); fall, 10 (10.20%); fight/fist blow, 9 (9.918%); plastic, 2 (2.04%); fingernails, 2 (2.04%); farm tools/fruits, 2 (2.04%); and RTA, glass, and headbutt, each 1.02%. Farm implements/fruits as well as fingernails appear to be fairly common primary agents that cause an eye injury in the rural Enugu, Nigeria. In terms of prevalence, there was no significant difference between the urban and rural areas. The findings from this study showed a high prevalence of eye injury among primary school children. In terms of treatment, 58.16% of the children with an eye injury had no form of treatment for it. The children from this study with monocular blindness did not receive adequate medical treatment. Treatment of an eye injury, according to this study, was sought from chemists (19.39%), at hospital/health centers (16.33%), at home (3.06%), and from traditional healers (3.06%). The persons who treated an eye injury, as observed from this study, were doctors (14.29%), nurses (4.08%), chemists (17.35%), and traditional healers and fathers (3.06% each). The frequency of noninjury-related diagnosis made in this study was refractive error, 4.85%; allergic conjunctivitis, 1.94%; oculocutaneous albinism, 0.24%; prepapillary vascular loops, 0.40%; and then ptosis, exotropia, stye, corneal opacity, and retinitis pigmentosa, 0.08% each. The annual incidence of an eye injury according to this study was 3.48%. The majority of the causes of an eye injury, as per this study, were preventable. Appropriate promotion of preventive eye care among children may go a long way in reducing the burden of blindness from eye injuries. PMID:26124686

  3. Microincision Hydrophobic Acrylic Aspheric Toric Intraocular Lens for Astigmatism and Cataract Correction.

    PubMed

    Bissen-Miyajima, Hiroko; Negishi, Kazuno; Hieda, Osamu; Kinoshita, Shigeru

    2015-06-01

    To evaluate the efficacy and safety of a new acrylic one-piece toric intraocular lens (IOL). This prospective multicenter clinical trial included 93 eyes of 61 patients that were implanted with a hydrophobic acrylic toric IOL from 2010 to 2012 and followed for 1 year. This IOL uses the platform of a microincision one-piece aspheric IOL, the NY-60 IOL (HOYA, Tokyo, Japan), with three increments in cylindrical power (NHT15, 1.5 diopters [D]; NHT23, 2.25 D; and NHT30, 3.0 D). The inclusion criterion was preoperative corneal astigmatism from 0.75 to 3.00 D. The primary endpoint was uncorrected distance visual acuity (UDVA) of 0.0 logMAR (20/20 Snellen) or better 6 months postoperatively. In addition to UDVA, corrected distance visual acuity (CDVA), residual astigmatism, stability of the IOL alignment, need of realignment, and the rate of Nd:YAG laser capsulotomy were evaluated up to 1 year postoperatively. Errors in astigmatic correction were assessed using Alpin's vector analysis. The primary endpoint was achieved in 54.8% of eyes. One year postoperatively, the logMAR UDVAs were 0.02 ± 0.13, 0.05 ± 0.17, and 0.09 ± 0.14 with models NHT15, NHT23, and NHT30, which corresponds to 0.96 (19/20 Snellen), 0.89 (18/20 Snellen), and 0.82 (16/20 Snellen), respectively. One year postoperatively, the residual astigmatism was 0.66 ± 0.58 D. In each evaluation, the mean absolute change in the position of the axis mark was between 1.93° and 2.32°. Three eyes required repositioning of the IOL axis and 2 eyes received Nd:YAG laser capsulotomy. The correction error showed an undercorrection with against-the-rule astigmatism and overcorrection with with-the-rule astigmatism. The new one-piece toric IOL provided desirable clinical outcomes and stability in eyes with corneal astigmatism. Copyright 2015, SLACK Incorporated.

  4. Can we measure the intraocular pressure when the eyeball is against the pillow in the lateral decubitus position?

    PubMed

    Kim, Ho Soong; Park, Ki Ho; Jeoung, Jin Wook

    2013-11-01

    To evaluate the amount of intraocular pressure (IOP) change in the eye against the pillow in the lateral decubitus position (LDP). Thirty eyes from 15 healthy volunteers (12 men and three women) aged 29 ± 3 (range 25-37) years participated in this study. Using the rebound tonometer (Icare PRO, Icare Finland Oy, Helsinki, Finland), the IOP of both eyes was checked in sitting, supine, right and left LDPs. In the LDP, the additional IOP measurements were taken with the lower eyeball against the latex pillow. Baseline IOP in the sitting position was 12.7 ± 1.9 mmHg in the right eye and 12.8 ± 2.2 mmHg in the left eye. Ten minutes after shifting from the sitting to the supine position, IOP increased significantly (right eye: +1.4 ± 1.4 mmHg, p = 0.006; left eye: +1.8 ± 1.5 mmHg, p = 0.001). Changing from the supine to the right and left LDP increased significantly the IOP of dependent eye (right eye: +2.3 ± 1.8 mmHg, p = 0.001; left eye: +1.5 ± 1.8 mmHg, p = 0.011). When the dependent eye was compressed against the pillow in the LDP, the IOP of the dependent eyes increased significantly after 10 min (right eye in the right LDP: +4.1 ± 4.9 mmHg, p = 0.011; left eye in the left LDP: +3.4 ± 3.7 mmHg, p = 0.006). The IOP was significantly elevated when the eyeball was against the pillow in the LDP. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.

  5. Association of iris crypts with acute primary angle closure.

    PubMed

    Koh, Victor; Chua, Jacqueline; Shi, Yuan; Thakku, Sri Gowtham; Lee, Ryan; Nongpiur, Monisha E; Baskaran, Mani; Kumar, Rajesh S; Perera, Shamira; Aung, Tin; Cheng, Ching-Yu

    2017-10-01

    To determine the relationship between iris surface features and acute primary angle closure (APAC) in eyes with angle closure. Case-control study involving Asian patients diagnosed with previous APAC, primary angle closure suspect (PACS), primary angle closure (PAC) and primary angle closure glaucoma (PACG) at an eye centre in Singapore between August 2012 and January 2015. Participants underwent ophthalmic examination and digital slit-lamp iris photography. Iris surface features were graded based on crypts, furrows and colour. Fellow eyes of APAC were compared with PACS and PAC/PACG eyes with regard to their iris surface features. Occurrence of APAC. A total of 309 patients (71 APAC, 139 PACS, 47 PAC and 52 PACG) were included (mean age: 67.7±7.2 years and 36.6% male). Compared with PACS, higher crypt grade was significantly associated with lower odds of APAC (OR=0.58 for one grade higher in crypt grade; p=0.027, adjusted for age, gender, ethnicity and pupil diameter). The results remained similar when compared with PAC/PACG group (OR=0.58 for one grade higher in crypt grade; p=0.043). We did not observe any significant associations between iris furrows or colour with presence of APAC. Our study comprising Asian eyes with angle closure suggests that the presence of a higher crypt grading may be protective for APAC. As such, assessing iris surface architecture for crypts could be a new measure for risk stratification of developing APAC in eyes with angle closure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Mobile Apps for Eye Care in Canada: An Analysis of the iTunes Store.

    PubMed

    Rodin, Alexander; Shachak, Aviv; Miller, Aaron; Akopyan, Vladimir; Semenova, Nataliya

    2017-06-14

    Mobile phone screens can facilitate stimulation to various components of the visual system and many mobile apps are accepted as a means of providing clinical assessments for the oculo-visual system. Although many of these apps are intended for use in clinical settings, there is a growing number of apps in eye care developed for self-tests and eye exercises for lay people. These and other features, however, have not yet been well described. Our objective was to identify, describe, and categorize mobile apps related to eye care that are available to users in the Canadian iTunes market. We conducted an extensive search of the Apple iTunes Store for apps related to eye care. We used the terms "eye," "eye care," "vision," and "eye test" and included apps that are targeted at both lay people and medical professionals. We excluded apps whose primary function is not related to eye care. Eligible apps were categorized by primary purpose, based on how they were described by their developers in the iTunes Store. Our search yielded 10,657 apps, of which 427 met our inclusion criteria. After removing duplicates, 355 unique apps were subject to further review. We assigned the eligible apps to three distinct categories: 39/355 apps (11.0%) were intended for use by medical professionals, 236 apps (66.5%, 236/355) were intended for use by lay people, and 80 apps (22.5%, 80/355) were intended for marketing eye care and eye-care products. We identified 9 subcategories of apps based on the descriptions of their primary functions. Apps for medical professionals fell into three subcategories: clinical calculators (n=6), clinical diagnostic tools (n=18), and education and networking apps for professionals (n=15). Apps for lay people fell into four subcategories: self-testing (n=153), eye exercises (n=30), patient tools and low vision aids (n=35), and apps for patient education (n=18). Mixed-use apps (n=80) were placed into two subcategories: marketing of individual practitioners or eye-care products (n=72) and marketing of multiple eye-care products or professional services. The most extensive subcategory pertaining to eye care consisted of apps for use by lay people, especially for conducting self-tests (n=236). This study revealed a previously uncharacterized category of apps intended for use by doctors and patients, of which the primary goal is marketing of eye-care services and products (n=80). ©Alexander Rodin, Aviv Shachak, Aaron Miller, Vladimir Akopyan, Nataliya Semenova. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 14.06.2017.

  7. Smooth-pursuit eye-movement-related neuronal activity in macaque nucleus reticularis tegmenti pontis.

    PubMed

    Suzuki, David A; Yamada, Tetsuto; Yee, Robert D

    2003-04-01

    Neuronal responses that were observed during smooth-pursuit eye movements were recorded from cells in rostral portions of the nucleus reticularis tegmenti pontis (rNRTP). The responses were categorized as smooth-pursuit eye velocity (78%) or eye acceleration (22%). A separate population of rNRTP cells encoded static eye position. The sensitivity to pursuit eye velocity averaged 0.81 spikes/s per degrees /s, whereas the average sensitivity to pursuit eye acceleration was 0.20 spikes/s per degrees /s(2). Of the eye-velocity cells with horizontal preferences for pursuit responses, 56% were optimally responsive to contraversive smooth-pursuit eye movements and 44% preferred ipsiversive pursuit. For cells with vertical pursuit preferences, 61% preferred upward pursuit and 39% preferred downward pursuit. The direction selectivity was broad with 50% of the maximal response amplitude observed for directions of smooth pursuit up to +/-85 degrees away from the optimal direction. The activities of some rNRTP cells were linearly related to eye position with an average sensitivity of 2.1 spikes/s per deg. In some cells, the magnitude of the response during smooth-pursuit eye movements was affected by the position of the eyes even though these cells did not encode eye position. On average, pursuit centered to one side of screen center elicited a response that was 73% of the response amplitude obtained with tracking centered at screen center. For pursuit centered on the opposite side, the average response was 127% of the response obtained at screen center. The results provide a neuronal rationale for the slow, pursuit-like eye movements evoked with rNRTP microstimulation and for the deficits in smooth-pursuit eye movements observed with ibotenic acid injection into rNRTP. More globally, the results support the notion of a frontal and supplementary eye field-rNRTP-cerebellum pathway involved with controlling smooth-pursuit eye movements.

  8. Management of pseudophakic myopic anisometropic amblyopia with piggyback Visian® implantable collamer lens.

    PubMed

    Eissa, Sherif A

    2017-03-01

    To assess the outcomes of sulcus implantation of the Visian ® implantable collamer lens (ICL) to correct pseudophakic myopic anisometropic amblyopia with myopic shift and/or primary refractive overcorrection. Prospective case series enrolled 14 pseudophakic eyes of 14 patients, 5-9 years old, with history of cataract surgery and primary in the bag-intraocular lenses (IOL) implantation, followed by myopic shift and/or refractive overcorrection and anisometropic amblyopia of variable degrees. All cases had implantation of a piggyback ICL/toric ICL, to correct the myopia/myopic astigmatism. Preoperatively, we evaluated the uncorrected distance visual acuity (UCVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and endothelial cell density (ECD). We assessed the position and vaulting of the ICLs on slit lamp examination and confirmed by Scheimpflug tomography. Postoperative follow-up was at 1st week and 1, 3, 6, 9, 12, 18 and 24 months. Uncorrected distance visual acuity improved in all cases, and CDVA improved in 11 amblyopic eyes (2-4 lines). There was no evidence of interlenticular opacification (ILO) throughout the 2-year follow-up. Two cases were complicated with early postoperative acute elevation of IOP and were controlled with topical beta-blockers. Postoperative acute anterior uveitis occurred in six eyes and controlled by topical steroids. Implantable collamer lens (ICL) vault was measured using Pentacam, with mean value of 470 ± 238 μm. Sulcus implantation of the secondary piggyback ICL to correct unilateral pseudophakic myopic refractive error in children was safe, efficient, predictable and well tolerated in management of anisometropic amblyopia in all eyes. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Analysis of age-dependence of the anterior and posterior cornea with scheimpflug imaging.

    PubMed

    Nemeth, Gabor; Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo

    2013-05-01

    To assess keratometric and higher-order aberrations of the anterior and posterior cornea and their age-related changes. This study investigated one healthy eye of 227 patients (mean age: 55.15 ± 21.2 years; range: 16 to 90 years; 135 right eyes, 92 left eyes). Images were captured from each eye with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) using automatic mode. Keratometric, astigmatism data, and corneal higher-order aberrations were analyzed. With respect to laterality, no deviance was found in any of the parameters (P > .05). Mean refractive error was 0.52 ± 0.23 diopters. The level of astigmatism decreased significantly with advancing age for both the anterior and posterior corneal surfaces (P < .05). The overall root mean square of the higher-order aberration increased continuously with age (r = 0.517; P < .01), which can be explained by the combined effect of the increased in both the anterior and posterior corneal root mean square higher-order aberrations. Of the higher-order aberrations, the constant increase of the primary and secondary spherical aberration with aging (P < .01) is caused by the spherical aberration growth of the anterior surface. Apart from these, only the vertical coma aberration of the posterior surface and the vertical trefoil aberrations of both the anterior and posterior surfaces showed a significantly positive correlation with aging (P < .05). Corneal astigmatism showed a significant decrease with aging. Of the higher-order aberrations, primary and secondary spherical aberrations, vertical coma, and vertical trefoil significantly increase with age, whereas other higher-order aberrations show no correlation with aging. Copyright 2013, SLACK Incorporated.

  10. Proprioceptive role for palisade endings in extraocular muscles: evidence from the Jendrassik Maneuver.

    PubMed

    Niechwiej-Szwedo, E; González, E; Bega, S; Verrier, M C; Wong, A M; Steinbach, M J

    2006-07-01

    A proprioceptive hypothesis for the control of eye movements has been recently proposed based on neuroanatomical tracing studies. It has been suggested that the non-twitch motoneurons could be involved in modulating the gain of sensory feedback from the eye muscles analogous to the gamma (gamma) motoneurons which control the gain of proprioceptive feedback in skeletal muscles. We conducted behavioral and psychophysical experiments to test the above hypothesis using the Jendrassik Maneuver (JM) to alter the activity of gamma motoneurons. It was hypothesized that the JM would alter the proprioceptive feedback from the eye muscles which would result in misregistration of eye position and mislocalization of targets. In the first experiment, vergence eye movements and pointing responses were examined. Data showed that the JM affected the localization responses but not the actual eye position. Perceptual judgments were tested in the second experiment, and the results showed that targets were perceived as farther when the afferent feedback was altered by the JM. Overall, the results from the two experiments showed that eye position was perceived as more divergent with the JM, but the actual eye movements were not affected. We tested this further in Experiment 3 by examining the effect of JM on the amplitude and velocity of saccadic eye movements. As expected, there were no significant differences in saccadic parameters between the control and experimental conditions. Overall, the present study provides novel insight into the mechanism which may be involved in the use of sensory feedback from the eye muscles. Data from the first two experiments support the hypothesis that the JM alters the registered eye position, as evidenced by the localization errors. We propose that the altered eye position signal is due to the effect of the JM which changes the gain of the sensory feedback from the eye muscles, possibly via the activity of non-twitch motoneurons.

  11. Safety and effectiveness of primary transscleral diode laser cyclophotoablation for glaucoma in Nigeria.

    PubMed

    Abdull, Mohammed M; Broadway, David C; Evans, Jennifer; Kyari, Fatima; Muazu, Fatima; Gilbert, Clare

    2018-05-28

    To investigate the safety, effectiveness and follow up rates after transscleral diode laser cyclophotocoagulation as primary treatment for seeing eyes with primary open angle glaucoma in Bauchi, Nigeria. There is a high prevalence of primary open angle glaucoma in Africa where adherence to medical treatment and acceptance of surgery are poor. Prospective case series PARTICIPANTS: New glaucoma patients where surgical intervention was recommended. A diode 810nm laser G-probe was used under retrobulbar anaesthesia to deliver approximately 20 shots for 2000ms, titrating the power. If both eyes were treated the first was the study eye. Repeat treatment offered if the intraocular pressure (IOP) was >21mmHg on two consecutive visits. Intraocular pressure <22mmHg, change in ≥2 lines of Snellen visual acuity, and complications. 201/204 eyes with complete data analysed. Mean age 52 years, 17 (8.3%) eyes were re-treated. Mean pre-treatment IOP was 39 (SD 11) mmHg. 106 (53%) attended at 12 months when the mean IOP was 19 (7-45) mmHg; 77 (73%) had IOP <22mmHg. Visual acuities were better in 13 (12.3%) and worse in 23 (21.7%) eyes. Post-operative complications included mild uveitis (5.5%), corneal oedema (2.5%), severe uveitis (0.5%) and transient hypotony (2.0%). No hypotony at 12 months. Transscleral diode laser cyclophotocoagulation controlled IOP in almost three quarters of eyes at 12 months with short-term preservation of vision and minimal complications. Poor follow-up in this setting highlights the need for an effective, safe and acceptable treatment where regular follow-up is less critical. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  12. Combined Brown syndrome and superior oblique palsy without a trochlear nerve: case report.

    PubMed

    Yang, Hee Kyung; Kim, Jae Hyoung; Kim, Ji-Soo; Hwang, Jeong-Min

    2017-08-25

    Congenital Brown syndrome is characterized by limited elevation particularly during adduction. The pathogenesis of congenital Brown syndrome is still controversial. A 6-year-old boy had been tilting his head to the left since infancy. He showed right hypertropia (RHT) of 2 prism diopters (Δ) in the primary position. He showed RHT 6Δ in right gaze, RHT 2Δ in left gaze, RHT 12Δ in right head tilt, and orthotropia in left head tilt. The right eye showed limitation of elevation and depression on adduction, and the left eye showed overdepression on adduction. MR images showed an absent right trochlear nerve with a hypoplastic ipsilateral superior oblique muscle. Congenital Brown syndrome may be associated with an absent trochlear nerve and hypoplastic superior oblique muscle suggesting an etiologic mechanism of congenital cranial dysinnervation disorder.

  13. Validating older adults' reports of less mind-wandering: An examination of eye movements and dispositional influences.

    PubMed

    Frank, David J; Nara, Brent; Zavagnin, Michela; Touron, Dayna R; Kane, Michael J

    2015-06-01

    The Control Failures × Concerns theory perspective proposes that mind-wandering occurs, in part, because of failures to inhibit distracting thoughts from entering consciousness (McVay & Kane, 2012). Despite older adults (OAs) exhibiting poorer inhibition, they report less mind-wandering than do young adults (YAs). Proposed explanations include (a) that OAs' thought reports are less valid due to an unawareness of, or reluctance to report, task-unrelated thoughts (TUTs) and (b) that dispositional factors protect OAs from mind-wandering. The primary goal of the current study was to test the validity of thought reports via eye-tracking. A secondary goal was to examine whether OAs' greater mindfulness (Splevins, Smith, & Simpson, 2009) or more positive mood (Carstensen, Isaacowitz, & Charles, 1999) protects them from TUTs. We found that eye movement patterns predicted OAs' TUT reports and YAs' task-related interference (TRI, or thoughts about one's performance) reports. Additionally, poor comprehension was associated with more TUTs in both age groups and more TRI in YAs. These results support the validity of OAs' thought reports. Concerning the second aim of the study, OAs' greater tendency to observe their surroundings (a facet of mindfulness) was related to increased TRI, and OAs' more positive mood and greater motivation partially mediated age differences in TUTs. OAs' reduced TUT reports appear to be genuine and potentially related to dispositional factors. (c) 2015 APA, all rights reserved.

  14. Screening of eye-position related genes with DD-RT-PCR and RDA in the hybrids between Japanese flounder Paralichthys olivaceus and stone flounder Kareius bicoloratus

    NASA Astrophysics Data System (ADS)

    Chen, Yanjie; Zhang, Quanqi; Qi, Jie; Sun, Yeying; Zhong, Qiwang; Wang, Xubo; Wang, Zhigang; Li, Shuo; Li, Chunmei

    2009-02-01

    Flatfish or flounder moves one eye to change body proportion into vertebral asymmetry during metamorphosis, during which some become sinistral while others dextral. However, the mechanism behinds the eye-position has not been well understood. In this research, hybrids between Japanese flounder(♀) and stone flounder (♂) show mixed eye-location in both dextral type and sinistral type, and thus become good samples for studying the eye-migration. mRNAs from pro-metamorphosis sinistral and dextral hybrids larvae were screened with classical differential display RT-PCR (DD-RT-PCR) and representational difference analysis of cDNA (cDNA-RDA); 30 and 47 putative fragments were isolated, respectively. The cDNA fragments of creatine kinase and trypsinogen 2 precursor genes isolated by cDNA-RDA exhibited eye-position expression patterns during metamorphosis. However, none of the fragments was proved to be related to flatfishes’ eye-position specifically. Therefore, further studies and more sensitive gene isolated methods are needed to solve the problems.

  15. Double silicone tube intubation for the management of partial lacrimal system obstruction.

    PubMed

    Demirci, Hakan; Elner, Victor M

    2008-02-01

    To evaluate the effectiveness of double silicone intubation for the management of partial lacrimal drainage system obstruction in adults. Observational retrospective case series. Twenty-four eyes of 18 consecutive adult patients with partial lacrimal system obstruction managed at the University of Michigan. Retrospective review of symptoms and signs, duration of silicone intubation, and complications. Resolution of tearing. Preoperative tearing, negative Jones I testing, positive Jones II testing, and resistance to positive-pressure irrigation were present in all eyes (100%). The first silicone tube was removed after a mean of 11+/-7 months, and the second tube after 16+/-6 months. Postoperatively, at a mean of 21+/-9 months after removal of both tubes, tearing remained resolved in 19 eyes (79%) and remained improved in 2 eyes (8%). In eyes with resolved tearing, Jones I testing became positive, and there was no resistance to positive-pressure irrigation. Persistent tearing in 3 eyes (13%) required treatment with external dacryocystorhinostomy. The only complication was peripunctal pyogenic granulomas in 2 eyes. Double silicone intubation is an effective minimally invasive technique for treatment of partial lacrimal system obstruction in adults.

  16. Eyes on the prize or nose to the grindstone? The effects of level of goal evaluation on mood and motivation.

    PubMed

    Houser-Marko, Linda; Sheldon, Kennon M

    2008-11-01

    These studies tested the hypothesis that evaluating goal feedback in terms of a primary, longer term goal can be risky for future motivation. Study 1 was a 2 x 2 experiment in which framing level (primary goal/subgoal) and feedback valence (success/failure) were manipulated for participants during a verbal skills task. In the primary goal failure condition, there was increased negative mood and decreased positive mood and expectancy for subsequent trials, even while controlling for goal difficulty and importance. Study 2 was an 8-week study throughout which participants were asked to evaluate their progress regarding a primary goal (class grade goal) or subgoal (weekly study hours goal), and success or failure varied naturally. When progress was lacking, participants in the primary goal condition experienced the largest decreases in mood and expectancy. These results suggest that it is optimal to evaluate goal progress at the lower, subgoal level, particularly after failure feedback.

  17. Pathophysiology of intraocular pressure increase and glaucoma prevalence in thyroid eye disease: a mini-review.

    PubMed

    Haefliger, I O; von Arx, G; Pimentel, A-R

    2010-04-01

    The aim of this study was to assess the pathophysiological mechanisms leading to intraocular pressure (IOP) increase and to review the prevalence of glaucoma in thyroid eye disease (TED), an autoimmune reaction affecting extra-ocular muscles and intra-orbital content in thyrotoxicosis (Grave's disease, hyperthyroidism). We applied the modified Friedenswald's and Goldmann's equations to explain the mechanisms by which IOP increases in TED and gave a brief review of the literature. In TED, Friedenswald's equation explains the ultra-short term IOP increase observed when eyes deviate from their primary gaze position (eyeball compression by enlarged and infiltrated extra-ocular muscles). Goldmann's equation explains the long-term IOP increase seen in TED (episcleral venous pressure elevation secondary to intraorbital content and pressure increase). Most studies did not find a significant increase in glaucoma prevalence in patients with TED. In TED, glaucoma prevalence does not seem to be significantly increased and, from a pathophysiological standpoint, the long-term IOP increase is essentially due to episcleral venous pressure elevation. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  18. Eye Care Quality and Accessibility Improvement in the Community (EQUALITY) for adults at risk for glaucoma: study rationale and design.

    PubMed

    Owsley, Cynthia; Rhodes, Lindsay A; McGwin, Gerald; Mennemeyer, Stephen T; Bregantini, Mary; Patel, Nita; Wiley, Demond M; LaRussa, Frank; Box, Dan; Saaddine, Jinan; Crews, John E; Girkin, Christopher A

    2015-11-18

    Primary open angle glaucoma is a chronic, progressive eye disease that is the leading cause of blindness among African Americans. Glaucoma progresses more rapidly and appears about 10 years earlier in African Americans as compared to whites. African Americans are also less likely to receive comprehensive eye care when glaucoma could be detected before irreversible blindness. Screening and follow-up protocols for managing glaucoma recommended by eye-care professional organizations are often not followed by primary eye-care providers, both ophthalmologists and optometrists. There is a pressing need to improve both the accessibility and quality of glaucoma care for African Americans. Telemedicine may be an effective solution for improving management and diagnosis of glaucoma because it depends on ocular imaging and tests that can be electronically transmitted to remote reading centers where tertiary care specialists can examine the results. We describe the Eye Care Quality and Accessibility Improvement in the Community project (EQUALITY), set to evaluate a teleglaucoma program deployed in retail-based primary eye care practices serving communities with a large percentage of African Americans. We conducted an observational, 1-year prospective study based in two Walmart Vision Centers in Alabama staffed by primary care optometrists. EQUALITY focuses on new or existing adult patients who are at-risk for glaucoma or already diagnosed with glaucoma. Patients receive dilated comprehensive examinations and diagnostic testing for glaucoma, followed by the optometrist's diagnosis and a preliminary management plan. Results are transmitted to a glaucoma reading center where ophthalmologists who completed fellowship training in glaucoma review results and provide feedback to the optometrist, who manages the care of the patient. Patients also receive eye health education about glaucoma and comprehensive eye care. Research questions include diagnostic and management agreement between providers, the impact of eye health education on patients' knowledge and adherence to follow-up and medication, patient satisfaction, program cost-effectiveness, and EQUALITY's impact on Walmart pharmacy prescription rates. As eye-care delivery systems in the US strive to improve quality while reducing costs, telemedicine programs including teleglaucoma initiatives such as EQUALITY could contribute toward reaching this goal, particularly among underserved populations at-risk for chronic blinding diseases.

  19. [Clinical features and treatment of choroidal metastasis].

    PubMed

    Wang, Guang-lu; Wang, Ming-yang; Wei, Wen-bin

    2009-03-01

    To assess the clinical features and management of choroidal metastasis. Fundus examination was performed in 49 patients (66 eyes) with choroidal metastasis. Fundus fluorescein angiography (FFA) was performed in 44 cases, combined with indocyanine green angiography (ICGA) examination in 12 cases. B-scan ultrasound examination was performed in 8 cases. Transpupillary thermotherapy (TTT) was performed in 24 eyes, combined with photo-dynamic therapy in one eye. Plaque radio-therapy was used in one eye. The parameters of treatment for TTT were 1.2 - 3 mm spot size, 450 - 1000 mV, 60 s; 2 sessions of TTT in 2 eyes and 3 sessions in 3 eyes. Fourteen cases were male and 35 cases were female. Both eyes were affected in 17 cases (34.7%). Age ranged from 23 - 74 years old with an average of 47 years. The visual acuity was 0.05 or less in 13 eyes; 0.06 - 0.2 in 22 eyes and 0.3 or more in 31 eyes. Primary tumours were found in 40 cases (81.6%) (surgical excision in 25 cases), consisting of breast carcinoma in 16 cases (32.7%), lung carcinoma in 14 cases (28.6%), hepatoma and cholangiocarcinoma in 3 cases, colon and stomach carcinomas in 3 cases, gynecologic appendix carcinoma (including 1 case of ovarian mucous cyst adenocarcinoma) in 2 cases, nasopharyngeal adenocarcinoma in 1 case, vertebra tumor in 1 case, undetected in 5 cases (10.2%) and under detection in 4 cases (8.2%). The fundus had 1 lesion in 58 eyes (58/66 = 87.8%), 2 lesions in 4 eyes (4/66 = 6.0%), 3 or more lesions in 2 eyes (including 7 lesions in 1 eye). According to the location and development status of the lesions, they could be divided into solitary type, 39 eyes (39/66 = 59.1%); diffuse type, 19 eyes (19/66 = 28.8%); and early type, 8 eyes (8/66 = 12.1%). FFA examination: early stage lesions showed hypofluorescence and later stage lesions showed moderate to strong hyperfluorescence. In 8 cases of solitary lesions, the size of the lesion measured by B-scan averaged 11.5 mm x 10.5 mm x 3.6 mm with the maximal height at 4.9 mm. The tumor became flattened and vision remained stable at 3 months after plaque radiotherapy in 1 case. Three cases were followed-up for 2, 3, and 4 months after TTT treatment. The lesions remained stable with vision unchanged or slightly decreased. The choroidal metastasis has specific clinical features. The classification of metastatic lesions into solitary, diffuse and early types is helpful for the evaluation of the disease process. The primary tumor can be found in 80% of cases. The most common primary cancer is breast carcinoma, followed by lung carcinoma. These two cancers account for 75% of primary tumors. In solitary type and early type lesions, TTT combines with systemic treatment could result in regression of lesions, saving of vision and improvement of the life quality.

  20. What Does the Eye See? Reading Online Primary Source Photographs in History

    ERIC Educational Resources Information Center

    Levesque, Stephane; Ng-A-Fook, Nicholas; Corrigan, Julie

    2014-01-01

    This exploratory study looks at how a sample of preservice teachers and historians read visuals in the context of school history. The participants used eye tracking technology and think-aloud protocol, as they examined a series of online primary source photographs from a virtual exhibit. Voluntary participants (6 students and 2 professional…

  1. Precision of higher-order aberration measurements with a new Placido-disk topographer and Hartmann-Shack wavefront sensor.

    PubMed

    López-Miguel, Alberto; Martínez-Almeida, Loreto; González-García, María J; Coco-Martín, María B; Sobrado-Calvo, Paloma; Maldonado, Miguel J

    2013-02-01

    To assess the intrasession and intersession precision of ocular, corneal, and internal higher-order aberrations (HOAs) measured using an integrated topographer and Hartmann-Shack wavefront sensor (Topcon KR-1W) in refractive surgery candidates. IOBA-Eye Institute, Valladolid, Spain. Evaluation of diagnostic technology. To analyze intrasession repeatability, 1 experienced examiner measured eyes 9 times successively. To study intersession reproducibility, the same clinician obtained measurements from another set of eyes in 2 consecutive sessions 1 week apart. Ocular, corneal, and internal HOAs were obtained. Coma and spherical aberrations, 3rd- and 4th-order aberrations, and total HOAs were calculated for a 6.0 mm pupil diameter. For intrasession repeatability (75 eyes), excellent intraclass correlation coefficients (ICCs) were obtained (ICC >0.87), except for internal primary coma (ICC = 0.75) and 3rd-order (ICC = 0.72) HOAs. Repeatability precision (1.96 × S(w)) values ranged from 0.03 μm (corneal primary spherical) to 0.08 μm (ocular primary coma). For intersession reproducibility (50 eyes), ICCs were good (>0.8) for ocular primary spherical, 3rd-order, and total higher-order aberrations; reproducibility precision values ranged from 0.06 μm (corneal primary spherical) to 0.21 μm (internal 3rd order), with internal HOAs having the lowest precision (≥0.12 μm). No systematic bias was found between examinations on different days. The intrasession repeatability was high; therefore, the device's ability to measure HOAs in a reliable way was excellent. Under intersession reproducibility conditions, dependable corneal primary spherical aberrations were provided. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Interactions of cervico-ocular and vestibulo-ocular fast-phase signals in the control of eye position in rabbits.

    PubMed Central

    Barmack, N H; Errico, P; Ferraresi, A; Pettorossi, V E

    1989-01-01

    1. Eye movements in unanaesthetized rabbits were studied during horizontal neck-proprioceptive stimulation (movement of the body with respect to the fixed head), when this stimulation was given alone and when it was given simultaneously with vestibular stimulation (rotation of the head-body). The effect of neck-proprioceptive stimulation on modifying the anticompensatory fast-phase eye movements (AFPs) evoked by vestibular stimulation was studied with a 'conditioning-test' protocol; the 'conditioning' stimulus was a neck-proprioceptive signal evoked by a step-like change in body position with respect to the head and the 'test' stimulus was a vestibular signal evoked by a step rotation of the head-body. 2. The influence of eye position and direction of slow eye movements on the occurrence of compensatory fast-phase eye movements (CFPs) evoked by neck-proprioceptive stimulation was also examined. 3. The anticompensatory fast phase (AFP) evoked by vestibular stimulation was attenuated by a preceding neck-proprioceptive stimulus which when delivered alone evoked compensatory slow-phase eye movements (CSP) in the same direction as the CSP evoked by vestibular stimulation. Conversely, the vestibularly evoked AFP was potentiated by a neck-proprioceptive stimulus which evoked CSPs opposite to that of vestibularly evoked CSPs. 4. Eccentric initial eye positions increased the probability of occurrence of midline-directed compensatory fast-phase eye movements (CFPs) evoked by appropriate neck-proprioceptive stimulation. 5. The gain of the horizontal cervico-ocular reflex (GHCOR) was measured from the combined changes in eye position resulting from AFPs and CSPs. GHCOR was potentiated during simultaneous vestibular stimulation. This enhancement of GHCOR occurred at neck-proprioceptive stimulus frequencies which, in the absence of conjoint vestibular stimulation, do not evoke CSPs. PMID:2795479

  3. Vergence-mediated changes in the axis of eye rotation during the human vestibulo-ocular reflex can occur independent of eye position.

    PubMed

    Migliaccio, Americo A; Cremer, Phillip D; Aw, Swee T; Halmagyi, G Michael; Curthoys, Ian S; Minor, Lloyd B; Todd, Michael J

    2003-07-01

    The aim of this study was to determine whether vergence-mediated changes in the axis of eye rotation in the human vestibulo-ocular reflex (VOR) would obey Listing's Law (normally associated with saccadic eye movements) independent of the initial eye position. We devised a paradigm for disassociating the saccadic velocity axis from eye position by presenting near and far targets that were centered with respect to one eye. We measured binocular 3-dimensional eye movements using search coils in ten normal subjects and 3-dimensional linear head acceleration using Optotrak in seven normal subjects. The stimuli consisted of passive, unpredictable, pitch head rotations with peak acceleration of approximately 2000 degrees /s(2 )and amplitude of approximately 20 degrees. During the pitch head rotation, each subject fixated straight ahead with one eye, whereas the other eye was adducted 4 degrees during far viewing (94 cm) and 25 degrees during near viewing (15 cm). Our data showed expected compensatory pitch rotations in both eyes, and a vergence-mediated horizontal rotation only in the adducting eye. In addition, during near viewing we observed torsional eye rotations not only in the adducting eye but also in the eye looking straight ahead. In the straight-ahead eye, the change in torsional eye velocity between near and far viewing, which began approximately 40 ms after the start of head rotation, was 10+/-6 degrees /s (mean +/- SD). This change in torsional eye velocity resulted in a 2.4+/-1.5 degrees axis tilt toward Listing's plane in that eye. In the adducting eye, the change in torsional eye velocity between near and far viewing was 16+/-6 degrees /s (mean +/- SD) and resulted in a 4.1+/-1.4 degrees axis tilt. The torsional eye velocities were conjugate and both eyes partially obeyed Listing's Law. The axis of eye rotation tilted in the direction of the line of sight by approximately one-third of the angle between the line of sight and a line orthogonal to Listing's plane. This tilt was higher than predicted by the one-quarter rule. The translational acceleration component of the pitch head rotation measured 0.5 g and may have contributed to the increased torsional component observed during near viewing. Our data show that vergence-mediated eye movements obey a VOR/Listing's Law compromise strategy independent of the initial eye position.

  4. Computer vision syndrome: a review of ocular causes and potential treatments.

    PubMed

    Rosenfield, Mark

    2011-09-01

    Computer vision syndrome (CVS) is the combination of eye and vision problems associated with the use of computers. In modern western society the use of computers for both vocational and avocational activities is almost universal. However, CVS may have a significant impact not only on visual comfort but also occupational productivity since between 64% and 90% of computer users experience visual symptoms which may include eyestrain, headaches, ocular discomfort, dry eye, diplopia and blurred vision either at near or when looking into the distance after prolonged computer use. This paper reviews the principal ocular causes for this condition, namely oculomotor anomalies and dry eye. Accommodation and vergence responses to electronic screens appear to be similar to those found when viewing printed materials, whereas the prevalence of dry eye symptoms is greater during computer operation. The latter is probably due to a decrease in blink rate and blink amplitude, as well as increased corneal exposure resulting from the monitor frequently being positioned in primary gaze. However, the efficacy of proposed treatments to reduce symptoms of CVS is unproven. A better understanding of the physiology underlying CVS is critical to allow more accurate diagnosis and treatment. This will enable practitioners to optimize visual comfort and efficiency during computer operation. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.

  5. Attention to gaze and emotion in schizophrenia.

    PubMed

    Schwartz, Barbara L; Vaidya, Chandan J; Howard, James H; Deutsch, Stephen I

    2010-11-01

    Individuals with schizophrenia have difficulty interpreting social and emotional cues such as facial expression, gaze direction, body position, and voice intonation. Nonverbal cues are powerful social signals but are often processed implicitly, outside the focus of attention. The aim of this research was to assess implicit processing of social cues in individuals with schizophrenia. Patients with schizophrenia or schizoaffective disorder and matched controls performed a primary task of word classification with social cues in the background. Participants were asked to classify target words (LEFT/RIGHT) by pressing a key that corresponded to the word, in the context of facial expressions with eye gaze averted to the left or right. Although facial expression and gaze direction were irrelevant to the task, these facial cues influenced word classification performance. Participants were slower to classify target words (e.g., LEFT) that were incongruent to gaze direction (e.g., eyes averted to the right) compared to target words (e.g., LEFT) that were congruent to gaze direction (e.g., eyes averted to the left), but this only occurred for expressions of fear. This pattern did not differ for patients and controls. The results showed that threat-related signals capture the attention of individuals with schizophrenia. These data suggest that implicit processing of eye gaze and fearful expressions is intact in schizophrenia. (c) 2010 APA, all rights reserved

  6. Bayesian microsaccade detection

    PubMed Central

    Mihali, Andra; van Opheusden, Bas; Ma, Wei Ji

    2017-01-01

    Microsaccades are high-velocity fixational eye movements, with special roles in perception and cognition. The default microsaccade detection method is to determine when the smoothed eye velocity exceeds a threshold. We have developed a new method, Bayesian microsaccade detection (BMD), which performs inference based on a simple statistical model of eye positions. In this model, a hidden state variable changes between drift and microsaccade states at random times. The eye position is a biased random walk with different velocity distributions for each state. BMD generates samples from the posterior probability distribution over the eye state time series given the eye position time series. Applied to simulated data, BMD recovers the “true” microsaccades with fewer errors than alternative algorithms, especially at high noise. Applied to EyeLink eye tracker data, BMD detects almost all the microsaccades detected by the default method, but also apparent microsaccades embedded in high noise—although these can also be interpreted as false positives. Next we apply the algorithms to data collected with a Dual Purkinje Image eye tracker, whose higher precision justifies defining the inferred microsaccades as ground truth. When we add artificial measurement noise, the inferences of all algorithms degrade; however, at noise levels comparable to EyeLink data, BMD recovers the “true” microsaccades with 54% fewer errors than the default algorithm. Though unsuitable for online detection, BMD has other advantages: It returns probabilities rather than binary judgments, and it can be straightforwardly adapted as the generative model is refined. We make our algorithm available as a software package. PMID:28114483

  7. Instrument Display Visual Angles for Conventional Aircraft and the MQ-9 Ground Control Station

    NASA Technical Reports Server (NTRS)

    Bendrick, Gregg A.; Kamine, Tovy Haber

    2008-01-01

    Aircraft instrument panels should be designed such that primary displays are in optimal viewing location to minimize pilot perception and response time. Human Factors engineers define three zones (i.e. "cones") of visual location: 1) "Easy Eye Movement" (foveal vision); 2) "Maximum Eye Movement" (peripheral vision with saccades), and 3) "Head Movement" (head movement required). Instrument display visual angles were measured to determine how well conventional aircraft (T-34, T-38, F- 15B, F-16XL, F/A-18A, U-2D, ER-2, King Air, G-III, B-52H, DC-10, B747-SCA) and the MQ-9 ground control station (GCS) complied with these standards, and how they compared with each other. Methods: Selected instrument parameters included: attitude, pitch, bank, power, airspeed, altitude, vertical speed, heading, turn rate, slip/skid, AOA, flight path, latitude, longitude, course, bearing, range and time. Vertical and horizontal visual angles for each component were measured from the pilot s eye position in each system. Results: The vertical visual angles of displays in conventional aircraft lay within the cone of "Easy Eye Movement" for all but three of the parameters measured, and almost all of the horizontal visual angles fell within this range. All conventional vertical and horizontal visual angles lay within the cone of "Maximum Eye Movement". However, most instrument vertical visual angles of the MQ-9 GCS lay outside the cone of "Easy Eye Movement", though all were within the cone of "Maximum Eye Movement". All the horizontal visual angles for the MQ-9 GCS were within the cone of "Easy Eye Movement". Discussion: Most instrument displays in conventional aircraft lay within the cone of "Easy Eye Movement", though mission-critical instruments sometimes displaced less important instruments outside this area. Many of the MQ-9 GCS systems lay outside this area. Specific training for MQ-9 pilots may be needed to avoid increased response time and potential error during flight.

  8. Red eyes and red-flags: improving ophthalmic assessment and referral in primary care

    PubMed Central

    Kilduff, Caroline; Lois, Charis

    2016-01-01

    Up to five percent of primary care consultations are eye-related, yet 96% of General Practitioners (GPs) do not undergo postgraduate ophthalmology training. Most do not feel assured performing eye assessments. Some red eye conditions can become sight threatening, and often exhibit red-flag features. These features include moderate pain, photophobia, reduced visual acuity (VA), eye-trauma, or unilateral marked redness. The aim of this project was to improve primary care assessment and referral of patients presenting with red-flag features based on the NICE ‘Red Eye’ Clinical Knowledge Summary recommendations. Data was collected retrospectively from 139 red eye consultations. A practice meeting highlighted poor awareness of red-flag features, low confidence levels in eye assessments, and time-constraints during appointments. Interventions were based on feedback from staff. These included a primary care teaching session on red-flag features, a VA measurement tutorial, and provision of a red eye toolkit, including VA equipment, to each consultation room. At baseline, each patient had on average 0.9 red-flag features assessed. Only 36.0% (9/25) of patients with red-flag features were appropriately referred to same-day ophthalmology services. Following two improvement cycles, a significant improvement was seen in almost every parameter. On average, each patient had 2.7 red-flag features assessed (vs 0.9, p<0.001). VA was assessed in 55.6% of consultations (vs 7.9%, p<0.001), pain was quantified in 81.5% (vs 20.9%, p=0.005), eye-trauma or foreign-body (51.8% vs 8.6%, p<0.001), extent of redness was documented in 66.7% (vs 14.4%, p<0.001). Only photophobia remained poorly assessed (18.5% vs 14.4%, p=0.75). Following this, 75.0% (6/8) of patients were appropriately referred. This project reflected the literature regarding low confidence and inexperience amongst GPs when faced with ophthalmic conditions. Improvements in education are required to ensure accurate assessments can be undertaken in a time-constrained environment. PMID:27493748

  9. Using InterWave Aberrometry to Measure and Improve the Quality of Vision in LASIK Surgery

    PubMed Central

    Thompson, Keith P.; Staver, P. Randall; Garcia, Jose R.; Burns, Stephen A.; Webb, Robert H.; Stulting, R. Doyle

    2005-01-01

    Objective To compare visual outcomes in eyes undergoing aberrometry-guided (InterWave) LASIK with those in eyes undergoing standard LASIK treatment based upon refractive measures. Design Single-center, comparative, interventional, consecutive case series. Participants Four hundred two consecutive eyes undergoing LASIK were analyzed retrospectively. One group, 106 eyes undergoing primary LASIK and 224 eyes undergoing LASIK enhancement, was treated with standard LASIK treatment using a 5.5-mm optical zone, 1.5-mm transition zone laser with the settings determined by manifest refraction. The second group, 44 untreated (primary) eyes and 28 previously treated (enhancement) eyes, received a multipass, multistage treatment in which the laser settings for each stage were determined by aberrometry measurements. Eyes with desired monovision (undercorrected) outcome and preoperative hyperopia were excluded from the study. Intervention An aberrometry-guided laser treatment (InterWave LASIK) was compared with the standard LASIK treatment based upon the manifest refraction. Main Outcome Measures Uncorrected visual acuity (VA), manifest refraction, best spectacle-corrected VA (BSCVA), severity of halos, and root mean square (RMS) retinal blur area measured at 3 months postoperatively. Results Three months postoperatively there was no difference in uncorrected VA, BSCVA, refraction, or RMS retinal blur areas for pupil sizes of 3.5 mm between eyes treated by InterWave and those treated by standard LASIK. However, InterWave LASIK reduced the retinal blur area by 48% (P<0.0103) and 58% (P<0.0004) in primary cases and 43% (P<0.0430) and 74% (P<0.0271) in enhancement cases, respectively, for pupil sizes of 4.5 and 6.5 mm relative to standard LASIK treatments. Patients undergoing InterWave-guided treatment reported less severity of halo (0.37 vs. 0.98 [P<0.016] for primary cases and 0.35 vs. 0.73 [P<0.04] for enhancement cases). Conclusion InterWave LASIK achieved acuity and refractive results equivalent to those of standard LASIK treatment based upon refraction, but resulted in superior quality mesopic vision. PMID:15234139

  10. Treatment of geographic atrophy with subconjunctival sirolimus: results of a phase I/II clinical trial.

    PubMed

    Wong, Wai T; Dresner, Samuel; Forooghian, Farzin; Glaser, Tanya; Doss, Lauren; Zhou, Mei; Cunningham, Denise; Shimel, Katherine; Harrington, Molly; Hammel, Keri; Cukras, Catherine A; Ferris, Frederick L; Chew, Emily Y

    2013-04-26

    To investigate the safety and effects of subconjunctival sirolimus, an mTOR inhibitor and immunosuppressive agent, for the treatment of geographic atrophy (GA). The study was a single-center, open-label phase II trial, enrolling 11 participants with bilateral GA; eight participants completed 24 months of follow-up. Sirolimus (440 μg) was administered every 3 months as a subconjunctival injection in only one randomly assigned eye in each participant for 24 months. Fellow eyes served as untreated controls. The primary efficacy outcome measure was the change in the total GA area at 24 months. Secondary outcomes included changes in visual acuity, macular sensitivity, central retinal thickness, and total drusen area. The study drug was well tolerated with few symptoms and related adverse events. Study treatment in study eyes was not associated with structural or functional benefits relative to the control fellow eyes. At month 24, mean GA area increased by 54.5% and 39.7% in study and fellow eyes, respectively (P = 0.41), whereas mean visual acuity decreased by 21.0 letters and 3.0 letters in study and fellow eyes, respectively (P = 0.03). Substantial differences in mean changes in drusen area, central retinal thickness, and macular sensitivity were not detected for all analysis time points up to 24 months. Repeated subconjunctival sirolimus was well-tolerated in patients with GA, although no positive anatomic or functional effects were identified. Subconjunctival sirolimus may not be beneficial in the prevention of GA progression, and may potentially be associated with effects detrimental to visual acuity. (ClinicalTrials.gov number, NCT00766649.).

  11. 3D Display Using Conjugated Multiband Bandpass Filters

    NASA Technical Reports Server (NTRS)

    Bae, Youngsam; White, Victor E.; Shcheglov, Kirill

    2012-01-01

    Stereoscopic display techniques are based on the principle of displaying two views, with a slightly different perspective, in such a way that the left eye views only by the left eye, and the right eye views only by the right eye. However, one of the major challenges in optical devices is crosstalk between the two channels. Crosstalk is due to the optical devices not completely blocking the wrong-side image, so the left eye sees a little bit of the right image and the right eye sees a little bit of the left image. This results in eyestrain and headaches. A pair of interference filters worn as an optical device can solve the problem. The device consists of a pair of multiband bandpass filters that are conjugated. The term "conjugated" describes the passband regions of one filter not overlapping with those of the other, but the regions are interdigitated. Along with the glasses, a 3D display produces colors composed of primary colors (basis for producing colors) having the spectral bands the same as the passbands of the filters. More specifically, the primary colors producing one viewpoint will be made up of the passbands of one filter, and those of the other viewpoint will be made up of the passbands of the conjugated filter. Thus, the primary colors of one filter would be seen by the eye that has the matching multiband filter. The inherent characteristic of the interference filter will allow little or no transmission of the wrong side of the stereoscopic images.

  12. Underwater binocular imaging of aerial objects versus the position of eyes relative to the flat water surface.

    PubMed

    Barta, András; Horváth, Gábor

    2003-12-01

    The apparent position, size, and shape of aerial objects viewed binocularly from water change as a result of the refraction of light at the water surface. Earlier studies of the refraction-distorted structure of the aerial binocular visual field of underwater observers were restricted to either vertically or horizontally oriented eyes. Here we calculate the position of the binocular image point of an aerial object point viewed by two arbitrarily positioned underwater eyes when the water surface is flat. Assuming that binocular image fusion is performed by appropriate vergent eye movements to bring the object's image onto the foveae, the structure of the aerial binocular visual field is computed and visualized as a function of the relative positions of the eyes. We also analyze two erroneous representations of the underwater imaging of aerial objects that have occurred in the literature. It is demonstrated that the structure of the aerial binocular visual field of underwater observers distorted by refraction is more complex than has been thought previously.

  13. Characteristic optical coherence tomography findings in patients with primary vitreoretinal lymphoma: a novel aid to early diagnosis.

    PubMed

    Barry, Robert J; Tasiopoulou, Anastasia; Murray, Philip I; Patel, Praveen J; Sagoo, Mandeep S; Denniston, Alastair K; Keane, Pearse A

    2018-01-06

    The diagnosis of primary vitreoretinal lymphoma (PVRL) poses significant difficulties; presenting features are non-specific and confirmation usually necessitates invasive vitreoretinal biopsy. Diagnosis is often delayed, resulting in increased morbidity and mortality. Non-invasive imaging modalities such as spectral domain optical coherence tomography (SD-OCT) offer simple and rapid aids to diagnosis. We present characteristic SD-OCT images of patients with biopsy-positive PVRL and propose a number of typical features, which we believe are useful in identifying these lesions at an early stage. Medical records of all patients attending Moorfields Eye Hospital between April 2010 and April 2016 with biopsy-positive PVRL were reviewed. Pretreatment SD-OCT images were collected for all eyes and were reviewed independently by two researchers for features suggestive of PVRL. Pretreatment SD-OCT images of 32 eyes of 22 patients with biopsy-proven PVRL were reviewed. Observed features included hyper-reflective subretinal infiltrates (17/32), hyper-reflective infiltration in inner retinal layers (6/32), retinal pigment epithelium (RPE) undulation (5/32), clumps of vitreous cells (5/32) and sub-RPE deposits (3/32). Of these, the hyper-reflective subretinal infiltrates have an appearance unique to PVRL, with features not seen in other diseases. We have identified a range of SD-OCT features, which we believe to be consistent with a diagnosis of PVRL. We propose that the observation of hyper-reflective subretinal infiltrates as described is highly suggestive of PVRL. This case series further demonstrates the utility of SD-OCT as a non-invasive and rapid aid to diagnosis, which may improve both visual outcomes and survival of patients with intraocular malignancies such as PVRL. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Phenotypical characteristics of idiopathic infantile nystagmus with and without mutations in FRMD7.

    PubMed

    Thomas, Shery; Proudlock, Frank A; Sarvananthan, Nagini; Roberts, Eryl O; Awan, Musarat; McLean, Rebecca; Surendran, Mylvaganam; Kumar, A S Anil; Farooq, Shegufta J; Degg, Chris; Gale, Richard P; Reinecke, Robert D; Woodruff, Geoffrey; Langmann, Andrea; Lindner, Susanne; Jain, Sunila; Tarpey, Patrick; Raymond, F Lucy; Gottlob, Irene

    2008-05-01

    Idiopathic infantile nystagmus (IIN) consists of involuntary oscillations of the eyes. The familial form is most commonly X-linked. We recently found mutations in a novel gene FRMD7 (Xq26.2), which provided an opportunity to investigate a genetically defined and homogeneous group of patients with nystagmus. We compared clinical features and eye movement recordings of 90 subjects with mutation in the gene (FRMD7 group) to 48 subjects without mutations but with clinical IIN (non-FRMD7 group). Fifty-eight female obligate carriers of the mutation were also investigated. The median visual acuity (VA) was 0.2 logMAR (Snellen equivalent 6/9) in both groups and most patients had good stereopsis. The prevalence of strabismus was also similar (FRMD7: 7.8%, non-FRMD7: 10%). The presence of anomalous head posture (AHP) was significantly higher in the non-FRMD7 group (P < 0.0001). The amplitude of nystagmus was more strongly dependent on the direction of gaze in the FRMD7 group being lower at primary position (P < 0.0001), compared to non-FRMD7 group (P = 0.83). Pendular nystagmus waveforms were also more frequent in the FRMD7 group (P = 0.003). Fifty-three percent of the obligate female carriers of an FRMD7 mutation were clinically affected. The VA's in affected females were slightly better compared to affected males (P = 0.014). Subnormal optokinetic responses were found in a subgroup of obligate unaffected carriers, which may be interpreted as a sub-clinical manifestation. FRMD7 is a major cause of X-linked IIN. Most clinical and eye movement characteristics were similar in the FRMD7 group and non-FRMD7 group with most patients having good VA and stereopsis and low incidence of strabismus. Fewer patients in the FRMD7 group had AHPs, their amplitude of nystagmus being lower in primary position. Our findings are helpful in the clinical identification of IIN and genetic counselling of nystagmus patients.

  15. Viewing condition dependence of the gaze-evoked nystagmus in Arnold Chiari type 1 malformation.

    PubMed

    Ghasia, Fatema F; Gulati, Deepak; Westbrook, Edward L; Shaikh, Aasef G

    2014-04-15

    Saccadic eye movements rapidly shift gaze to the target of interest. Once the eyes reach a given target, the brainstem ocular motor integrator utilizes feedback from various sources to assure steady gaze. One of such sources is cerebellum whose lesion can impair neural integration leading to gaze-evoked nystagmus. The gaze evoked nystagmus is characterized by drifts moving the eyes away from the target and a null position where the drifts are absent. The extent of impairment in the neural integration for two opposite eccentricities might determine the location of the null position. Eye in the orbit position might also determine the location of the null. We report this phenomenon in a patient with Arnold Chiari type 1 malformation who had intermittent esotropia and horizontal gaze-evoked nystagmus with a shift in the null position. During binocular viewing, the null was shifted to the right. During monocular viewing, when the eye under cover drifted nasally (secondary to the esotropia), the null of the gaze-evoked nystagmus reorganized toward the center. We speculate that the output of the neural integrator is altered from the bilateral conflicting eye in the orbit position secondary to the strabismus. This could possibly explain the reorganization of the location of the null position. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Perceptions of eye health in schools in Pakistan

    PubMed Central

    Ahmad, Khabir; Khan, Mohammad Aman; Khan, Mohammad Daud; Qureshi, Mohammad Babar; Chaudhry, Tanveer Anjum; Gilbert, Clare

    2006-01-01

    Background Research exploring children's and their teachers' perceptions of eye health is lacking. This paper reports for the first time on perceptions of primary schoolchildren and their teachers of healthy and diseased eyes, things that keep eyes healthy and damage them, and what actions to be taken in case of an eye injury. Methods Using draw and write technique, 160 boys and girls (9–12 years old) attending four primary schools in Abbottabad district, northern Pakistan, were invited to draw pictures in response to a set of semi-structured questions and then label them. Sixteen teachers who were currently teaching the selected students were interviewed one-on-one. Results Analysis of text accompanying 800 drawings and of the interview scripts revealed that most children and teachers perceived healthy eyes to be those which could see well, and diseased eyes to be those which have redness, watering, dirty discharge, pain, and itching; or those which have "weak eyesight" and blindness. Among things that students and teachers thought damage the eyes included sun, television, and sharp pointed objects, particularly pencils. Teachers noted that children with eye problems "have difficulty seeing the blackboard well", "screw up their eyes", and "hold their books too close". Conclusion We conclude that schoolchildren and their teachers had a good knowledge of eye health, but many of them had serious misconceptions e.g., use of kohl, medicines and eye drops keeps eyes healthy. Kohl is an important source of lead and can reduce children's intelligence even at low blood levels. Health education in schools must take into account children's existing knowledge of and misconceptions about various aspects of eye health. Such steps if taken could improve the relevance of eye health education to schoolchildren. PMID:16512897

  17. Perceptions of eye health in schools in Pakistan.

    PubMed

    Ahmad, Khabir; Khan, Mohammad Aman; Khan, Mohammad Daud; Qureshi, Mohammad Babar; Chaudhry, Tanveer Anjum; Gilbert, Clare

    2006-03-02

    Research exploring children's and their teachers' perceptions of eye health is lacking. This paper reports for the first time on perceptions of primary schoolchildren and their teachers of healthy and diseased eyes, things that keep eyes healthy and damage them, and what actions to be taken in case of an eye injury. Using draw and write technique, 160 boys and girls (9-12 years old) attending four primary schools in Abbottabad district, northern Pakistan, were invited to draw pictures in response to a set of semi-structured questions and then label them. Sixteen teachers who were currently teaching the selected students were interviewed one-on-one. Analysis of text accompanying 800 drawings and of the interview scripts revealed that most children and teachers perceived healthy eyes to be those which could see well, and diseased eyes to be those which have redness, watering, dirty discharge, pain, and itching; or those which have "weak eyesight" and blindness. Among things that students and teachers thought damage the eyes included sun, television, and sharp pointed objects, particularly pencils. Teachers noted that children with eye problems "have difficulty seeing the blackboard well", "screw up their eyes", and "hold their books too close". We conclude that schoolchildren and their teachers had a good knowledge of eye health, but many of them had serious misconceptions e.g., use of kohl, medicines and eye drops keeps eyes healthy. Kohl is an important source of lead and can reduce children's intelligence even at low blood levels. Health education in schools must take into account children's existing knowledge of and misconceptions about various aspects of eye health. Such steps if taken could improve the relevance of eye health education to schoolchildren.

  18. The success of primary chemotherapy for group D heritable retinoblastoma.

    PubMed

    Cohen, V M L; Kingston, J; Hungerford, J L

    2009-07-01

    To report the ocular survival and event-free survival following primary multiagent chemotherapy for group D, heritable bilateral retinoblastoma (RB). The RB database was used to identify children with heritable, bilateral RB treated with primary chemotherapy (six cycles of vincristine, etoposide and carboplatin). Only Group D eyes with more than 12 months' follow-up were analysed. The timing, number and type of salvage treatments were recorded. Kaplan-Meier estimates for the ocular survival and event-free survival (percentage of eyes that avoided external beam radiotherapy and/or enucleation) were performed as a function of time. Of 18 group D eyes, two (11%) were treated successfully with chemotherapy alone, nine (50%) underwent successful salvage treatment, and seven (39%) were enucleated. The median time from completing chemotherapy to enucleation was 9 months (range 4 to 25 months). Ocular survival was 67% at 2 years. External beam radiotherapy proved successful salvage treatment in five of nine eyes, so the event-free survival was 34% at 2 years. Multiagent chemotherapy alone is rarely sufficient for the preservation of group D eyes. External beam radiotherapy and plaque radiotherapy remain important salvage treatments for advanced, heritable retinoblastoma.

  19. Critical involvement of extracellular ATP acting on P2RX7 purinergic receptors in photoreceptor cell death.

    PubMed

    Notomi, Shoji; Hisatomi, Toshio; Kanemaru, Takaaki; Takeda, Atsunobu; Ikeda, Yasuhiro; Enaida, Hiroshi; Kroemer, Guido; Ishibashi, Tatsuro

    2011-12-01

    Stressed cells release ATP, which participates in neurodegenerative processes through the specific ligation of P2RX7 purinergic receptors. Here, we demonstrate that extracellular ATP and the more specific P2RX7 agonist, 2'- and 3'-O-(4-benzoylbenzoyl)-ATP, both induce photoreceptor cell death when added to primary retinal cell cultures or when injected into the eyes from wild-type mice, but not into the eyes from P2RX7(-/-) mice. Photoreceptor cell death was accompanied by the activation of caspase-8 and -9, translocation of apoptosis-inducing factor from mitochondria to nuclei, and TUNEL-detectable chromatin fragmentation. All hallmarks of photoreceptor apoptosis were prevented by premedication or co-application of Brilliant Blue G, a selective P2RX7 antagonist that is already approved for the staining of internal limiting membranes during ocular surgery. ATP release is up-regulated by nutrient starvation in primary retinal cell cultures and seems to be an initializing event that triggers primary and/or secondary cell death via the positive feedback loop on P2RX7. Our results encourage the potential application of Brilliant Blue G as a novel neuroprotective agent in retinal diseases or similar neurodegenerative pathologies linked to excessive extracellular ATP. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  20. Eye movements in patients with schizophrenia: visual stimuli, semantic content and psychiatric symptoms.

    PubMed

    Ishizuka, K; Kashiwakura, M; Oiji, A

    1998-05-01

    In order to explore a possible association between psychiatric symptoms and eye movements, 32 patients with schizophrenia were examined using an eye mark recorder in combination with the Positive and Negative Syndrome Scale, and were compared with 32 controls. Four types of figures were presented to the subjects: geometrical figures, drawings, story drawings, and sentences. Mean eye fixation time was significantly longer and mean eye scanning length was significantly shorter for the patients than for controls, not only in response to the geometric figures, but also in response to the story drawings. Eye fixation time and scanning velocity were positively correlated with degrees of thought disturbance. The number of eye fixations, eye fixation time and scanning velocity were negatively correlated with degree of depressive tendency.

  1. Factors That Influence the Receipt of Eye Care

    PubMed Central

    Alexander, Robert L.; Miller, Nancy A.; Cotch, Mary Frances; Janiszewski, Rosemary

    2010-01-01

    Objectives To better understand what factors influence the receipt of eye care so that screening and education programs can be designed to promote early detection and treatment. Methods Twenty focus groups were conducted. Analyses entailed debriefing sessions, coding, and interpreting transcribed data. Results Attitudes about eyesight and eye exams influence the receipt of preventive eye care. Limited knowledge about certain eye diseases and conditions was reported. Participants stated that their primary care providers did not communicate information with them about eyesight nor did they conduct basic eye screenings. Conclusions Improving provider-patient interactions and developing public health messages about eye diseases and preventive eye care can facilitate increased use of appropriate eye care services. PMID:18241139

  2. [Virtual reality in ophthalmological education].

    PubMed

    Wagner, C; Schill, M; Hennen, M; Männer, R; Jendritza, B; Knorz, M C; Bender, H J

    2001-04-01

    We present a computer-based medical training workstation for the simulation of intraocular eye surgery. The surgeon manipulates two original instruments inside a mechanical model of the eye. The instrument positions are tracked by CCD cameras and monitored by a PC which renders the scenery using a computer-graphic model of the eye and the instruments. The simulator incorporates a model of the operation table, a mechanical eye, three CCD cameras for the position tracking, the stereo display, and a computer. The three cameras are mounted under the operation table from where they can observe the interior of the mechanical eye. Using small markers the cameras recognize the instruments and the eye. Their position and orientation in space is determined by stereoscopic back projection. The simulation runs with more than 20 frames per second and provides a realistic impression of the surgery. It includes the cold light source which can be moved inside the eye and the shadow of the instruments on the retina which is important for navigational purposes.

  3. Horizontal Saccadic Eye Movements Enhance the Retrieval of Landmark Shape and Location Information

    ERIC Educational Resources Information Center

    Brunye, Tad T.; Mahoney, Caroline R.; Augustyn, Jason S.; Taylor, Holly A.

    2009-01-01

    Recent work has demonstrated that horizontal saccadic eye movements enhance verbal episodic memory retrieval, particularly in strongly right-handed individuals. The present experiments test three primary assumptions derived from this research. First, horizontal eye movements should facilitate episodic memory for both verbal and non-verbal…

  4. Influence of eye rotation on peripheral eye length measurement obtained with a partial coherence interferometry instrument.

    PubMed

    Verkicharla, Pavan K; Suheimat, Marwan; Mallen, Edward A H; Atchison, David A

    2014-01-01

    The eye rotation approach for measuring peripheral eye length leads to concern about whether the rotation influences results, such as through pressure exerted by eyelids or extra-ocular muscles. This study investigated whether this approach is valid. Peripheral eye lengths were measured with a Lenstar LS 900 biometer for eye rotation and no-eye rotation conditions (head rotation for horizontal meridian and instrument rotation for vertical meridian). Measurements were made for 23 healthy young adults along the horizontal visual field (± 30°) and, for a subset of eight participants along the vertical visual field (± 25°). To investigate the influence of the duration of eye rotation, for six participants measurements were made at 0, 60, 120, 180 and 210 s after eye rotation to ± 30° along horizontal and vertical visual fields. Peripheral eye lengths were not significantly different for the conditions along the vertical meridian (F1,7 = 0.16, p = 0.71). The peripheral eye lengths for the conditions were significantly different along the horizontal meridian (F1,22 = 4.85, p = 0.04), although not at individual positions (p ≥ 0.10) and were not important. There were no apparent differences between the emmetropic and myopic groups. There was no significant change in eye length at any position after maintaining position for 210 s. Eye rotation and no-eye rotation conditions were similar for measuring peripheral eye lengths along horizontal and vertical visual field meridians at ± 30° and ± 25°, respectively. Either condition can be used to estimate retinal shape from peripheral eye lengths. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  5. Postural effects on intraocular pressure and ocular perfusion pressure in patients with non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Yang, Jee Myung; Park, Sang Woo; Ji, Yong Sok; Kim, Jaeryung; Yoo, Chungkwon; Heo, Hwan

    2017-04-20

    To investigate postural effects on intraocular pressure (IOP) and ocular perfusion pressure (OPP) in patients with non-arteritic ischemic optic neuropathy (NAION). IOP and blood pressure (BP) were measured in 20 patients with unilateral NAION 10 min after changing to each of the following positions sequentially: sitting, supine, right lateral decubitus position (LDP), supine, left LDP, and supine. IOP was measured using a rebound tonometer and OPP was calculated using formulas based on mean BP. The dependent LDP (DLDP) was defined as the position when the eye of interest (affected or unaffected eye) was placed on the dependent side in the LDP. IOPs were significantly higher (P = 0.020) and OPPs were significantly lower (P = 0.041) in the affected eye compare with the unaffected eye, with the affected eye in DLDP. Compared with the mean IOP of the unaffected eyes, the mean IOP of the affected eyes increased significantly (+2.9 ± 4.4 versus +0.7 ± 3.1 mmHg, respectively; P = 0.003) and the mean OPP decreased significantly (-6.7 ± 9.4 versus -4.9 ± 8.0 mmHg, respectively; P = 0.022) after changing positions from supine to DLDP. In addition, changing position from supine to DLDP showed significantly larger absolute changes in IOP (4.13 ± 3.19 mmHg versus 2.51 ± 1.92 mmHg, respectively; P = 0.004) and OPP (9.86 ± 5.69 mmHg versus 7.50 ± 5.49 mmHg, respectively; P = 0.009) in the affected eye compared with the unaffected eye. In the affected eye, there was a significant positive correlation between absolute change in IOP and OPP when changing position from supine to DLDP (Rho = 0.512, P = 0.021). A postural change from supine to DLDP caused significant fluctuations in IOP and OPP of the affected eye, and may significantly increase IOP and decrease OPP. Posture-induced IOP changes may be a predisposing factor for NAION development.

  6. Case-controlled clinical and histopathological study of conjunctivochalasis.

    PubMed

    Francis, I C; Chan, D G; Kim, P; Wilcsek, G; Filipic, M; Yong, J; Coroneo, M T

    2005-03-01

    Conjunctivochalasis, a secondary cause of the watery eye, is frequently seen in the older age group as an elevation of the bulbar conjunctiva lying along the lateral or central lower lid margin. A prospective, interventional, case-controlled clinical and histopathological study was conducted. The relevant features of 18 patients (29 eyes) who had their conjunctivochalasis resected as part of the surgical management of their watery eye syndrome were examined. In the control group, tissue was obtained from an age matched series of 24 normal subjects undergoing routine cataract surgery. 24 controls (24 specimens) and 18 patients (29 specimens) had conjunctival strip biopsies, taken from the usual lid margin level bulbar conjunctiva in line with the inferior limbus (controls), and the clinically apparent conjunctivochalasis (patients). These were submitted for histological study. 23 of 24 control sections demonstrated normal conjunctival variation. Four of 29 patient specimens demonstrated a chronic non-granulomatous conjunctivitis, while three eyes of the patient group (two patients) demonstrated features of elastosis. Of the four patients who had the inflammatory infiltrates, three had functional nasolacrimal duct obstructions (FNLDOs) and one had a primary acquired nasolacrimal duct obstruction (PANDO). Of the two patients who had elastosis, one had an FNLDO and the other had normal lacrimal drainage and was Jones 1 positive. Six of 18 patients--that is, seven of 29 specimens of conjunctivochalasis demonstrated signs of elastosis or of chronic non-granulomatous inflammation. Clinically, patients had a spectrum of aetiologies of their watery eye syndrome.

  7. New therapeutic modality for corneal endothelial disease using Rho-associated kinase inhibitor eye drops.

    PubMed

    Koizumi, Noriko; Okumura, Naoki; Ueno, Morio; Kinoshita, Shigeru

    2014-11-01

    Corneal endothelial dysfunction accompanied by visual disturbance is a primary indication for corneal endothelial transplantation. However, despite the value and potential of endothelial graft surgery, a strictly pharmacological approach for treating corneal endothelial dysfunction remains an attractive proposition. Previously, we reported that the selective Rho-associated kinase (ROCK) inhibitor Y-27632 promotes cell adhesion and proliferation, and inhibits the apoptosis of primate corneal endothelial cells in culture. These findings have led us to develop a novel medical treatment for the early phase of corneal endothelial disease using ROCK inhibitor eye drops. In rabbit and monkey models of partial endothelial dysfunction, we showed that corneal endothelial wound healing was accelerated via the topical application of ROCK inhibitor to the ocular surface, resulting in the regeneration of a corneal endothelial monolayer with a high endothelial cell density. Based on these animal studies, we are now attempting to advance the clinical application of ROCK inhibitor eye drops for patients with corneal endothelial dysfunction. A pilot clinical study was performed at the Kyoto Prefectural University of Medicine, and the effects of Y-27632 eye drops after transcorneal freezing were evaluated in 8 patients with corneal endothelial dysfunction. We observed a positive effect of ROCK inhibitor eye drops in treating patients with central edema caused by Fuchs corneal endothelial dystrophy. We believe that our new findings will contribute to the establishment of a new approach for the treatment of corneal endothelial dysfunction.

  8. The influence of operator position, height and body orientation on eye lens dose in interventional radiology and cardiology: Monte Carlo simulations versus realistic clinical measurements.

    PubMed

    Principi, S; Farah, J; Ferrari, P; Carinou, E; Clairand, I; Ginjaume, M

    2016-09-01

    This paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used. Monte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature. Simulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°-60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data. Simple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Vertical muscle transposition with silicone band belting in VI nerve palsy

    PubMed Central

    Freitas, Cristina

    2016-01-01

    A woman aged 60 years developed a Millard-Gubler syndrome after a diagnosis of a cavernous angioma in the median and paramedian areas of the pons. In this context, she presented a right VI nerve palsy, right conjugate gaze palsy, facial palsy and left hemiparesis. To improve the complete VI nerve palsy, we planned a modified transposition approach, in which procedure we made a partial transposition of vertical rectus with a silicone band that was fixated posteriorly. After the procedure, the patient gained the ability to slightly abduct the right eye. We found no compensatory torticollis in the primary position of gaze. There was also an improvement of elevation and depression movements of the right eye. We obtained satisfactory results with a theoretically reversible technique, which is adjustable intraoperatively with no need of muscle detachment, preventing anterior segment ischaemia and allowing simultaneous recession of the medial rectus muscles, if necessary. PMID:27974341

  10. An investigation of prescription and over-the-counter supply of ophthalmic chloramphenicol in Wales in the 5 years following reclassification.

    PubMed

    Du, Hank C T; John, Dai N; Walker, Roger

    2014-02-01

    The aims of the study were to (i) quantify the sales of over-the-counter (OTC) ophthalmic chloramphenicol from all community pharmacies in Wales and investigate the impact on primary care prescriptions up to 5 years after reclassification and (ii) investigate the temporal relationship between items supplied OTC and on NHS primary care prescriptions. Primary care prescription data (2004-2010) and OTC sales data (2005-2010) for ophthalmic chloramphenicol were obtained. The quantity sold OTC was calculated from pharmacy wholesale records and sales data from a large pharmacy multiple. Spearman's rank correlation for prescription and OTC supplies of ophthalmic chloramphenicol was calculated for data from January 2008 to December 2010. OTC supply of chloramphenicol eye drops and ointment were both highest in 2007-2008 and represented 68% (57,708/84,304) and 48% (22,875/47,192) of the corresponding prescription volume, respectively. There was a steady year-on-year increase in the combined supply of OTC ophthalmic chloramphenicol and that dispensed on prescription from 144,367 items in 2004-2005 to 210,589 in 2007-2008 before stabilising in 2008-2009 and 2009-2010. A significant positive correlation was observed between prescription items and OTC sales of chloramphenicol eye drops and ointment combined (r=0.7, P<0.001). OTC availability increased the total quantity of ophthalmic chloramphenicol supplied in primary care compared to that seen prior to reclassification. Although growth in the sales of ophthalmic chloramphenicol OTC has stabilised and the supply pattern mirrors primary care prescribers, further work is required to investigate whether use is appropriate and whether the publication of updated practice guidance has changed this. © 2013 The Authors. IJPP © 2013 Royal Pharmaceutical Society.

  11. A holographic waveguide based eye tracker

    NASA Astrophysics Data System (ADS)

    Liu, Changgeng; Pazzucconi, Beatrice; Liu, Juan; Liu, Lei; Yao, Xincheng

    2018-02-01

    We demonstrated the feasibility of using holographic waveguide for eye tracking. A custom-built holographic waveguide, a 20 mm x 60 mm x 3 mm flat glass substrate with integrated in- and out-couplers, was used for the prototype development. The in- and out-couplers, photopolymer films with holographic fringes, induced total internal reflection in the glass substrate. Diffractive optical elements were integrated into the in-coupler to serve as an optical collimator. The waveguide captured images of the anterior segment of the eye right in front of it and guided the images to a processing unit distant from the eye. The vector connecting the pupil center (PC) and the corneal reflex (CR) of the eye was used to compute eye position in the socket. An eye model, made of a high quality prosthetic eye, was used prototype validation. The benchtop prototype demonstrated a linear relationship between the angular eye position and the PC/CR vector over a range of 60 horizontal degrees and 30 vertical degrees at a resolution of 0.64-0.69 degrees/pixel by simple pixel count. The uncertainties of the measurements at different angular positions were within 1.2 pixels, which indicated that the prototype exhibited a high level of repeatability. These results confirmed that the holographic waveguide technology could be a feasible platform for developing a wearable eye tracker. Further development can lead to a compact, see-through eye tracker, which allows continuous monitoring of eye movement during real life tasks, and thus benefits diagnosis of oculomotor disorders.

  12. Abnormal Fixational Eye Movements in Amblyopia.

    PubMed

    Shaikh, Aasef G; Otero-Millan, Jorge; Kumar, Priyanka; Ghasia, Fatema F

    2016-01-01

    Fixational saccades shift the foveal image to counteract visual fading related to neural adaptation. Drifts are slow eye movements between two adjacent fixational saccades. We quantified fixational saccades and asked whether their changes could be attributed to pathologic drifts seen in amblyopia, one of the most common causes of blindness in childhood. Thirty-six pediatric subjects with varying severity of amblyopia and eleven healthy age-matched controls held their gaze on a visual target. Eye movements were measured with high-resolution video-oculography during fellow eye-viewing and amblyopic eye-viewing conditions. Fixational saccades and drifts were analyzed in the amblyopic and fellow eye and compared with controls. We found an increase in the amplitude with decreased frequency of fixational saccades in children with amblyopia. These alterations in fixational eye movements correlated with the severity of their amblyopia. There was also an increase in eye position variance during drifts in amblyopes. There was no correlation between the eye position variance or the eye velocity during ocular drifts and the amplitude of subsequent fixational saccade. Our findings suggest that abnormalities in fixational saccades in amblyopia are independent of the ocular drift. This investigation of amblyopia in pediatric age group quantitatively characterizes the fixation instability. Impaired properties of fixational saccades could be the consequence of abnormal processing and reorganization of the visual system in amblyopia. Paucity in the visual feedback during amblyopic eye-viewing condition can attribute to the increased eye position variance and drift velocity.

  13. Abnormal Fixational Eye Movements in Amblyopia

    PubMed Central

    Shaikh, Aasef G.; Otero-Millan, Jorge; Kumar, Priyanka; Ghasia, Fatema F.

    2016-01-01

    Purpose Fixational saccades shift the foveal image to counteract visual fading related to neural adaptation. Drifts are slow eye movements between two adjacent fixational saccades. We quantified fixational saccades and asked whether their changes could be attributed to pathologic drifts seen in amblyopia, one of the most common causes of blindness in childhood. Methods Thirty-six pediatric subjects with varying severity of amblyopia and eleven healthy age-matched controls held their gaze on a visual target. Eye movements were measured with high-resolution video-oculography during fellow eye-viewing and amblyopic eye-viewing conditions. Fixational saccades and drifts were analyzed in the amblyopic and fellow eye and compared with controls. Results We found an increase in the amplitude with decreased frequency of fixational saccades in children with amblyopia. These alterations in fixational eye movements correlated with the severity of their amblyopia. There was also an increase in eye position variance during drifts in amblyopes. There was no correlation between the eye position variance or the eye velocity during ocular drifts and the amplitude of subsequent fixational saccade. Our findings suggest that abnormalities in fixational saccades in amblyopia are independent of the ocular drift. Discussion This investigation of amblyopia in pediatric age group quantitatively characterizes the fixation instability. Impaired properties of fixational saccades could be the consequence of abnormal processing and reorganization of the visual system in amblyopia. Paucity in the visual feedback during amblyopic eye-viewing condition can attribute to the increased eye position variance and drift velocity. PMID:26930079

  14. An eye movement analysis of the effect of interruption modality on primary task resumption.

    PubMed

    Ratwani, Raj; Trafton, J Gregory

    2010-06-01

    We examined the effect of interruption modality (visual or auditory) on primary task (visual) resumption to determine which modality was the least disruptive. Theories examining interruption modality have focused on specific periods of the interruption timeline. Preemption theory has focused on the switch from the primary task to the interrupting task. Multiple resource theory has focused on interrupting tasks that are to be performed concurrently with the primary task. Our focus was on examining how interruption modality influences task resumption.We leverage the memory-for-goals theory, which suggests that maintaining an associative link between environmental cues and the suspended primary task goal is important for resumption. Three interruption modality conditions were examined: auditory interruption with the primary task visible, auditory interruption with a blank screen occluding the primary task, and a visual interruption occluding the primary task. Reaction time and eye movement data were collected. The auditory condition with the primary task visible was the least disruptive. Eye movement data suggest that participants in this condition were actively maintaining an associative link between relevant environmental cues on the primary task interface and the suspended primary task goal during the interruption. These data suggest that maintaining cue association is the important factor for reducing the disruptiveness of interruptions, not interruption modality. Interruption-prone computing environments should be designed to allow for the user to have access to relevant primary task cues during an interruption to minimize disruptiveness.

  15. Utility of Novel Autoantibodies in the Diagnosis of Sjögren's Syndrome Among Patients With Dry Eye.

    PubMed

    Karakus, Sezen; Baer, Alan N; Agrawal, Devika; Gurakar, Merve; Massof, Robert W; Akpek, Esen K

    2018-04-01

    To investigate the value of 3 novel autoantibodies [salivary protein 1 (SP1), carbonic anhydrase 6 (CA6), and parotid secretory protein (PSP)] in differentiating Sjögren's syndrome (SS)-related dry eye from non-SS dry eye. Forty-six dry eye patients with SS (SS dry eye), 14 dry eye patients without SS (non-SS dry eye), and 25 controls were included. The 2012 American College of Rheumatology classification criteria were used for the diagnosis of SS. After a detailed review of systems, the Ocular Surface Disease Index questionnaire, Schirmer test without anesthesia, tear film breakup time, and ocular surface staining were performed to assess dry eye. All participants underwent serological testing using a commercially available finger prick kit. Thirty-seven patients with SS (80.4%) had a positive traditional autoantibody and 28 (60.9%) had a positive novel autoantibody. Traditional autoantibodies were absent in all non-SS dry eye patients and controls. Novel autoantibodies were present in 7/14 (50%) non-SS dry eye patients and 4/25 (16%) controls. Among 3 novel autoantibodies, anti-CA6 was significantly more prevalent in the SS and non-SS dry eye groups than in controls (52.2% vs. 42.9% vs. 8.0%, P = 0.001). Dry eye patients with positive anti-CA6 alone were significantly younger than patients with only traditional autoantibodies. Anti-CA6 was associated with worse dry eye signs and symptoms. Anti-CA6 was the most prevalent novel autoantibody in patients with dry eye, and was associated with younger age and more severe disease. Longitudinal studies are needed to determine whether anti-CA6 is a marker for early SS or perhaps another form of an autoimmune dry eye disease.

  16. Encoding Strategies in Primary School Children: Insights from an Eye-Tracking Approach and the Role of Individual Differences in Attentional Control

    ERIC Educational Resources Information Center

    Roebers, Claudia M.; Schmid, Corinne; Roderer, Thomas

    2010-01-01

    The authors explored different aspects of encoding strategy use in primary school children by including (a) an encoding strategy task in which children's encoding strategy use was recorded through a remote eye-tracking device and, later, free recall and recognition for target items was assessed; and (b) tasks measuring resistance to interference…

  17. [Clinical and histopathologic analysis of superficial tissue proliferation following the implantation of keratoprosthesis].

    PubMed

    Dong, Ying; Huang, Yi-Fei; Liu, Qian; DU, Gai-Ping

    2011-05-01

    To investigate the clinical and histopathologic features of the superficial tissue proliferation (STP) following the implantation of MICOF keratoprosthesis, and to analyze the formation and treatment of STP. Retrospective study. Eighty-five patients (85 eyes) received MICOF keratoprosthesis surgery from January 2000 through December 2009 in General Hospital of PLA, which included 72 males and 13 females. The mean age of the patients was (45 ± 15) years. Preoperative diagnoses were ocular burn (56 eyes), end-stage of autoimmune dry eye (14 eyes), severe ocular trauma (10 eyes) and repeated graft failure (5 eyes). Postoperatively, STPs of Kpro were observed and treated. The membranes anterior to the optical cylinder were removed and investigated by histological and immunohistochemical methods, and anterior segment specimens from normal eyes were taken as control. Twenty-two (26%) patients presented STP during the follow-up, and proliferations occurred ranging from 2 to 63 months (median, 7 months). The incident rates of STP were 34% (19/56 eyes) in burned eyes, 14% (2/14 eyes) in end-stage dry eye, 10% (1/10 eyes) in severe mechanical ocular trauma, and none in repeated grafts failure. Difference among four groups did not arrive significance statistically (χ(2) = 5.93, P = 0.11). The epithelial proliferations were observed in 11 patients, which were removed easily. To prevent from recurrence, the height of the cylinder was adjusted. Other 4 patients underwent ultra-high frequency ocular surface plastic operation and 7 patients received membranectomy. Histologically, the superficial proliferative membrane was composed of proliferative epithelium and fibrovascular tissue incorporating inflammatory cells. The immunohistochemical staining demonstrated the expression of PCNA increased in the epithelium, compared with control cornea and conjunctiva. Many vimentin-positive fibroblasts and a few α-SMA-positive myofibroblasts presented in the interstitial tissue, and the numbers of CD45RO-positive T cells, CD11c-positive dendritic cells, and CD68-positive macrophages were increased in proliferative membranes. The tissue proliferation around optical cylinder results in membrane formation anterior to the Kpro. The excessive inflammation at the prosthesis-corneal junction and the unsuited height of the optical cylinder might have been the main reasons of STP.

  18. Automated nystagmus analysis. [on-line computer technique for eye data processing

    NASA Technical Reports Server (NTRS)

    Oman, C. M.; Allum, J. H. J.; Tole, J. R.; Young, L. R.

    1973-01-01

    Several methods have recently been used for on-line analysis of nystagmus: A digital computer program has been developed to accept sampled records of eye position, detect fast phase components, and output cumulative slow phase position, continuous slow phase velocity, instantaneous fast phase frequency, and other parameters. The slow phase velocity is obtained by differentiation of the calculated cumulative position rather than the original eye movement record. Also, a prototype analog device has been devised which calculates the velocity of the slow phase component during caloric testing. Examples of clinical and research eye movement records analyzed with these devices are shown.

  19. Rhegmatogenous retinal detachments associated to Stickler syndrome in a tertiary eye care center in Saudi Arabia.

    PubMed

    Alshahrani, Saeed T; Ghazi, Nicola G; Al-Rashaed, Saba

    2016-01-01

    To investigate the clinical findings and outcomes of rhegmatogenous retinal detachment (RRD) in Stickler syndrome on affected and fellow eyes that underwent prophylactic retinopexy. Chart review of 70 eyes (62 patients). Incidence of RRD, postoperative visual acuity, and risk factors were evaluated. Twenty-two patients (35%) had RRD in the fellow eye, 37% of the eyes had cataract, 93% had macular detachment, 50% had proliferative vitreoretinopathy, and 41% had posterior vitreous detachment. Success rates were: 60% of patients after scleral buckling; 57.1% after pars plana vitrectomy; and 75% after combined scleral buckling and pars plana vitrectomy. Sixty-one (93.8%) of patients had successful surgery (including second surgery). Silicone oil tamponade was significantly associated with final anatomic outcome, with a protective odds ratio of 0.11 (P=0.027). Visual acuity improved in 54% of eyes and decreased in 5%. Statistically significant associations were present for eyes with final visual acuity ≥20/200, and total retinal detachment (P<0.001); preoperative cataract (P=0.023); and proliferative vitreoretinopathy (P<0.001). RRD developed in 16/44 eyes despite laser prophylaxis. Prophylactic retinopexy was not beneficial for Stickler syndrome patients. Success of primary surgery for RRD remains low. The primary surgery should be vitrectomy combined with scleral buckling and silicone oil tamponade.

  20. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  1. Trabecular Meshwork Height in Primary Open-Angle Glaucoma Versus Primary Angle-Closure Glaucoma.

    PubMed

    Masis, Marisse; Chen, Rebecca; Porco, Travis; Lin, Shan C

    2017-11-01

    To determine if trabecular meshwork (TM) height differs between primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG) eyes. Prospective, cross-sectional clinical study. Adult patients were consecutively recruited from glaucoma clinics at the University of California, San Francisco, from January 2012 to July 2015. Images were obtained from spectral-domain optical coherence tomography (Cirrus OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA). Univariate and multivariate linear mixed models comparing TM height and glaucoma type were performed to assess the relationship between TM height and glaucoma subtype. Mixed-effects regression was used to adjust for the use of both eyes in some subjects. The study included 260 eyes from 161 subjects, composed of 61 men and 100 women. Mean age was 70 years (SD 11.77). There were 199 eyes (123 patients) in the POAG group and 61 eyes (38 patients) in the PACG group. Mean TM heights in the POAG and PACG groups were 812 ± 13 μm and 732 ± 27 μm, respectively, and the difference was significant in univariate analysis (P = .004) and in multivariate analysis (β = -88.7 [24.05-153.5]; P = .008). In this clinic-based population, trabecular meshwork height is shorter in PACG patients compared to POAG patients. This finding may provide insight into the pathophysiology of angle closure and provide assistance in future diagnosis, prevention, and management of the angle-closure spectrum of disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Screening for refractive error among primary school children in Bayelsa state, Nigeria

    PubMed Central

    Opubiri, Ibeinmo; Pedro-Egbe, Chinyere

    2013-01-01

    Introduction Vision screening study in primary school children has not been done in Bayelsa State. This study aims to screen for refractive error among primary school children in Bayelsa State and use the data to plan for school Eye Health Program. Methods A cross sectional study on screening for refractive error in school children was carried out in Yenagoa Local Government Area of Bayelsa State in June 2009. A multistage sampling technique was used to select the study population (pupils aged between 5-15 years). Visual acuity (VA) for each eye, was assessed outside the classroom at a distance of 6 meters. Those with VA ≤6/9 were presented with a pinhole and the test repeated. Funduscopy was done inside a poorly lit classroom. An improvement of the VA with pinhole was considered refractive error. Data was analyzed with EPI INFO version 6. Results A total of 1,242 school children consisting of 658 females and 584 males were examined.About 97.7% of pupils had normal VA (VA of 6/6) while 56 eyes had VAs ≤ 6/9. Of these 56 eyes, the visual acuity in 49 eyes (87.5%) improved with pinhole. Twenty seven pupils had refractive error, giving a prevalence of 2.2%. Refractive error involved both eyes in 22 pupils (81.5%) and the 8-10 years age range had the highest proportion (40.7%) of cases of refractive error followed by the 9-13 year-old age range (37%). Conclusion The prevalence of refractive error was 2.2% and most eyes (97.7%) had normal vision. PMID:23646210

  3. The Effect of Immunologically Safe Plasma Rich in Growth Factor Eye Drops in Patients with Sjögren Syndrome.

    PubMed

    Sanchez-Avila, Ronald Mauricio; Merayo-Lloves, Jesus; Riestra, Ana Cristina; Anitua, Eduardo; Muruzabal, Francisco; Orive, Gorka; Fernández-Vega, Luis

    2017-06-01

    The objective was to provide preliminary information about the efficacy and safety of immunologically safe plasma rich in growth factor (immunosafe PRGF) eye drops in the treatment of moderate to severe dry eye in patients with primary and secondary Sjögren's syndrome (SS) and to analyze the influence of several variables on treatment outcomes. This retrospective study included patients with SS. All patients were treated with previously immunosafe PRGF eye drops to reduce the immunologic component contents. Ocular Surface Disease Index (OSDI) scale, best-corrected visual acuity (BCVA), visual analog scale (VAS) frequency, and VAS severity outcome measures were evaluated before and after treatment with immunosafe PRGF. The potential influence of some patient clinical variables on results was also assessed. Safety assessment was also performed reporting all adverse events. Twenty-six patients (12 patients with primary SS, and 14 patients suffering secondary SS) with a total of 52 affected eyes were included and evaluated. Immunosafe PRGF treatment showed a significant reduction (P < 0.05) in OSDI scale (41.86%), in BCVA (62.97%), in VAS frequency (34.75%), and in VAS severity (41.50%). BCVA and VAS frequency scores improved significantly (P < 0.05) after concomitant treatment of PRGF with corticosteroids. Only 2 adverse events were reported in 2 patients (7.7% of patients). Signs and symptoms of dry eye syndrome in patients with SS were reduced after treatment with PRGF-Endoret eye drops. Immunosafe PRGF-Endoret is safe and effective for treating patients with primary and secondary SS.

  4. Primary iris claw IOL retrofixation with intravitreal triamcinolone acetonide in cases of inadequate capsular support.

    PubMed

    Kelkar, Aditya; Shah, Rachana; Vasavda, Viraj; Kelkar, Jai; Kelkar, Shreekant

    2018-02-01

    To assess the outcomes and analyze complication rates following primary iris claw IOL retrofixation with intravitreal triamcinolone acetonide. This is a retrospective interventional case series. Patients with poor capsular support-diagnosed preoperatively or owing to intraoperative complications-were treated with iris claw IOL retrofixation with intravitreal triamcinolone acetonide. The data were retrospectively analyzed. 104 eyes of 102 patients with poor capsular support who underwent the procedure between 2010 and 2013 were analyzed. The minimum follow-up period was 12 months (ranging from 12 to 36 months). Iris claw IOL was implanted in-traumatic subluxated cataracts-24 cases (23.07%), non-traumatic subluxated cataracts in 16 cases (15.38%), or as a complication of cataract surgery-intraoperative posterior capsular rent in 48 cases (46.15%) and intraoperative nucleus drop in 16 cases (15.38%). The final mean best-corrected logMAR visual acuity improved from 1.36 ± 0.64 preoperatively to 0.36 ± 0.32 at 1-year follow-up. Complications included pupil ovalization in 11 cases (10.57%), transient elevation in intraocular pressure in 7 eyes (6.73%), postoperative hypotony in 5 eyes (4.80%), cystoid macular edema in 2 eyes (1.92%), retinal detachment in 1 eye (0.96%), vitreous hemorrhage in 1 eye (0.96%), and hyphema in 1 eye (0.96%). Primary iris claw IOL retrofixation provided excellent alternative in patients with inadequate capsular support. The visual outcomes were good along with favorable rates of complications. The addition of triamcinolone acetonide helps in reducing the chances of cystoid macular edema.

  5. Two-dimensional analysis of palpebral opening in blepharoptosis: visual iris-pupil complex percentage by digital photography.

    PubMed

    Choi, Yeop; Eo, SuRak

    2014-04-01

    The vertical dimension of the palpebral fissure and the marginal reflex distance are conventionally used to assess the amount or degree of blepharoptosis, and levator function is assessed by measuring total upper lid excursion between the extremes of down-gaze and up-gaze. However, these are 1-dimensional measures obtained with a ruler, and the results obtained are dependent on examiner skill. Digital photographs were obtained of 692 patients before and after upper blepharoplasty. Visual iris-pupil complex percentage (VIP) was measured in the 1,305 eyes by digital calculation using Adobe Photoshop CS3 (Adobe Systems, Inc). Perioperative eye images in primary gaze were evaluated independently by 2 surgeons, 2 nurses, and a graphic designer, and after excluding 50 eyes which were nonconcordant and 29 eyes which revealed retracted upper lids, the remaining 1,305 eyes were classified into 4 major groups, that is, into excellent (n = 415), good (n = 435), subclinical (n = 270), and prominent ptosis (n = 185) groups. In addition, eyes were subdivided into 5 types according to the iris-pupil complex position within the palpebral fissure. Visual iris-pupil complex percentages were from 85% to 94% in the excellent, from 78% to 84% in the good, from 70% to 77% in the subclinical ptosis, and below 70% in the prominent ptosis group. Patients in the subclinical or prominent ptosis eye group required surgery for blepharoptosis. Iris-pupil complex relation to the palpebral opening was classified into 5 eye types, namely, standard (n = 961), scleral (n = 266), sinking (n = 151), retracted (n = 3), and fish (n = 3). The authors devised a new prospective measurement method for assessing blepharoptosis in a clinical setting. Graphical comparisons between the devised method of measuring VIP and mathematical estimations showed that the devised method is easier, more practical, and more precise for measuring degree of blepharoptosis from general population trends, and that VIP also provides a useful objective index for evaluating the postoperative results of blepharoptosis.

  6. The Magnitude and Time Course of IOP Change in Response to Body Position Change in Nonhuman Primates Measured Using Continuous IOP Telemetry

    PubMed Central

    Turner, Daniel C.; Samuels, Brian C.; Huisingh, Carrie; Girkin, Christopher A.

    2017-01-01

    Purpose To study the effect and time course of body position changes on IOP in nonhuman primates. Methods We recorded continuous bilateral IOP measurements with a wireless telemetry implant in three rhesus macaques in seven different body positions. IOP measurements were acquired in the seated-upright, standing, prone, supine, right and left lateral decubitus positions (LDPs), and head-down inverted positions. Continuous IOP was recorded for 90 seconds in each position before returning to a supine reference position until IOP stabilized; measurements were averaged after IOP stabilized at each position. Results Head-down inversion increased IOP an average of 8.9 mm Hg, compared to the supine reference. In the LDP, IOP decreased an average of 0.5 mm Hg in the nondependent eye (i.e., the higher eye), while the fellow dependent (i.e., lower) eye increased an average of 0.5 mm Hg, compared to supine reference. Standing and seated positions decreased IOP 1.5 and 2.2 mm Hg, respectively, compared with supine reference. IOP changes occurred within 4 to 15 seconds of a body position change, and timing was affected by the speed at which body position was changed. Compared to the IOP in the supine position, the IOP in the inverted, prone, and seated positions was significantly different (P = 0.0313 for all). The IOP in the standing position was not statistically different from the IOP in the supine position (P = 0.094). In addition, the IOP was significantly different between the nondependent eye and the dependent eye in the LDPs compared to the supine position (P = 0.0313). Conclusions Body position has a significant effect on IOP and those changes persist over time. PMID:29228251

  7. Vitreoretinal Complications and Outcomes in 92 Eyes Undergoing Surgery for Modified Osteo-Odonto-Keratoprosthesis: A 10-Year Review.

    PubMed

    Rishi, Pukhraj; Rishi, Ekta; Agarwal, Vishvesh; Nair, Sridevi; Iyer, Geetha; Srinivasan, Bhaskar; Agarwal, Shweta

    2018-06-01

    To analyze vitreoretinal (VR) complications and treatment outcomes in eyes undergoing modified osteo-odonto-keratoprosthesis (OOKP) surgery. Retrospective case series. All patients who underwent modified OOKP (mOOKP) surgery at a tertiary eye-care center from March 2003 to February 2013 were included. Medical records were reviewed for relevant medical history, best-corrected visual acuity (BCVA), slit-lamp examination, ultrasound scan, oral examination findings, and VR complications. The BCVA at the last visit. Optimal anatomic outcome was attached retina with a normal intraocular pressure at the last visit. A total of 92 eyes of 90 patients were included. Indications for OOKP included Stevens-Johnson syndrome (n = 53), chemical injury (n = 36), and ocular cicatricial pemphigoid (n = 3). A total of 41 eyes of 39 patients developed VR complications, including vitritis (n = 21), retinal detachment (RD) (n = 12; primary RD = 5), retroprosthetic membrane (RPM) (n = 10; primary RPM = 2), endophthalmitis (n = 8), vitreous hemorrhage (VH) (n = 5; primary VH = 1), serous choroidal detachment (n = 5), hemorrhagic choroidal detachment (n = 2), and leak-related hypotony (n = 1). Mean interval from mOOKP surgery to occurrence of VR complication(s) was 43.8 months (median, 41.9 months; range, 0.2-95.5 months). After treatment of VR complication, visual improvement was seen in 17 eyes (42%) (mean improvement = 1.2 logarithm of the minimum angle of resolution [logMAR]; median, 0.8 logMAR; range, 0.1-2.5 logMAR), visual decline in 7 eyes (14%) (mean decline in BCVA = 0.6 logMAR; median, 0.4 logMAR; range, 0.3-1.8 logMAR), and no change in BCVA in 17 eyes (42%). However, BCVA ≥6/60 was retained in 19 eyes and ≥6/18 was retained in 9 eyes after final VR treatment. Vitreoretinal complications constitute a significant cause of visual morbidity in eyes undergoing mOOKP surgery and pose a challenging situation to manage. However, appropriate and timely intervention can achieve encouraging results. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. Unusual presentations of melanoma: melanoma of unknown primary site, melanoma arising in childhood, and melanoma arising in the eye and on mucosal surfaces.

    PubMed

    Sondak, Vernon K; Messina, Jane L

    2014-10-01

    Most melanomas present as primary tumors on the skin surface in adults; however, melanomas also arise in the eye and on the mucosal surfaces or present as apparently metastatic disease without any known history of a cutaneous primary. Melanoma is also being diagnosed during childhood more frequently than ever. Surgeons need to be aware of and understand these unusual presentations of melanoma to optimally manage their patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Longitudinal Changes of Angle Configuration in Primary Angle-Closure Suspects

    PubMed Central

    Jiang, Yuzhen; Chang, Dolly S.; Zhu, Haogang; Khawaja, Anthony P.; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M.

    2015-01-01

    Objective To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Design Longitudinal cohort study. Participants Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Methods Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Main Outcome Measures Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. Results No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (P<0.001 for all variables). Between 2 weeks and 18 months after LPI, a significant decrease in angle width was observed over time in treated eyes (P<0.001 for all variables), although the change over the first 5.5 months was not statistically significant for angle width measured under gonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8–1.6) in treated eyes and 1.6°/year (95% CI, 1.3–2.0) in untreated eyes (P<0.001). Conclusions Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the same time period. PMID:24835757

  10. Face Inversion Disproportionately Disrupts Sensitivity to Vertical over Horizontal Changes in Eye Position

    ERIC Educational Resources Information Center

    Crookes, Kate; Hayward, William G.

    2012-01-01

    Presenting a face inverted (upside down) disrupts perceptual sensitivity to the spacing between the features. Recently, it has been shown that this disruption is greater for vertical than horizontal changes in eye position. One explanation for this effect proposed that inversion disrupts the processing of long-range (e.g., eye-to-mouth distance)…

  11. Effectiveness of an Eyelid Thermal Pulsation Procedure to Treat Recalcitrant Dry Eye Symptoms After Laser Vision Correction.

    PubMed

    Schallhorn, Craig S; Schallhorn, Julie M; Hannan, Stephen; Schallhorn, Steven C

    2017-01-01

    To provide an initial retrospective evaluation of the effectiveness of a thermal pulsation system to treat intractable patient-reported dye eye symptoms following laser vision correction. A total of 109 eyes of 57 patients underwent thermal pulsation therapy (LipiFlow; TearScience, Morrisville, NC) for the treatment of dry eye symptoms following laser vision correction. A standardized dry eye questionnaire, the Standard Patient Evaluation of Eye Dryness (SPEED II), was administered to all patients before and after thermal pulsation therapy. The primary outcome was patient-reported dry eye symptoms as measured by this questionnaire. The mean patient age was 49 years (interquartile range [IQR]: 38 to 60), 70% were female, and the primary refractive procedure was LASIK (n = 91, 83%) or photorefractive keratectomy (PRK) (n = 18, 17%). Patients underwent thermal pulsation therapy at a mean of 40.5 months (IQR: 27.6 to 55.0) after the primary procedure. The mean pre-therapy SPEED II questionnaire score was 17.5 (IQR: 14 to 21), with a reduced mean post-therapy score of 10.2 (IQR: 6 to 14; 95% confidence interval [CI]: 8.8 to 11.5, P < .001). Patients with PRK tended to report more improvement. At the follow-up clinical evaluation, objective improvements were noted in tear break-up time (+1.9 sec; 95% CI: 1.3 to 2.5), reduction in grade of meibomian gland dysfunction (-0.69; 95% CI: -0.54 to -0.84), and corneal staining (-0.74; 95% CI: -0.57 to -0.91). In this initial retrospective evaluation, a significant improvement in patient-reported dry eye symptoms was observed following thermal pulsation therapy. This treatment modality may have utility in the management of dry eye symptoms following laser vision correction, but further study is needed to define its role. [J Refract Surg. 2017;33(1):30-36.]. Copyright 2017, SLACK Incorporated.

  12. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Via, Riccardo, E-mail: riccardo.via@polimi.it; Fassi, Aurora; Fattori, Giovanni

    Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by twomore » calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.« less

  13. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy.

    PubMed

    Via, Riccardo; Fassi, Aurora; Fattori, Giovanni; Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Riboldi, Marco; Ciocca, Mario; Orecchia, Roberto; Baroni, Guido

    2015-05-01

    External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.

  14. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush.

    PubMed

    Groth, Sylvia L; Greider, Kelsi L; Sponsel, William Eric

    2015-01-01

    To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. Case series. Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.

  15. Comparison of patient evaluations of health care quality in relation to WHO measures of achievement in 12 European countries.

    PubMed

    Kerssens, Jan J; Groenewegen, Peter P; Sixma, Herman J; Boerma, Wienke G W; van der Eijk, Ingrid

    2004-02-01

    To gain insight into similarities and differences in patient evaluations of quality of primary care across 12 European countries and to correlate patient evaluations with WHO health system performance measures (for example, responsiveness) of these countries. Patient evaluations were derived from a series of Quote (QUality of care Through patients' Eyes) instruments designed to measure the quality of primary care. Various research groups provided a total sample of 5133 patients from 12 countries: Belarus, Denmark, Finland, Greece, Ireland, Israel, Italy, the Netherlands, Norway, Portugal, United Kingdom, and Ukraine. Intraclass correlations of 10 Quote items were calculated to measure differences between countries. The world health report 2000 - Health systems: improving performance performance measures in the same countries were correlated with mean Quote scores. Intra-class correlation coefficients ranged from low to very high, which indicated little variation between countries in some respects (for example, primary care providers have a good understanding of patients' problems in all countries) and large variation in other respects (for example, with respect to prescription of medication and communication between primary care providers). Most correlations between mean Quote scores per country and WHO performance measures were positive. The highest correlation (0.86) was between the primary care provider's understanding of patients' problems and responsiveness according to WHO. Patient evaluations of the quality of primary care showed large differences across countries and related positively to WHO's performance measures of health care systems.

  16. Correspondence of presaccadic activity in the monkey primary visual cortex with saccadic eye movements

    PubMed Central

    Supèr, Hans; van der Togt, Chris; Spekreijse, Henk; Lamme, Victor A. F.

    2004-01-01

    We continuously scan the visual world via rapid or saccadic eye movements. Such eye movements are guided by visual information, and thus the oculomotor structures that determine when and where to look need visual information to control the eye movements. To know whether visual areas contain activity that may contribute to the control of eye movements, we recorded neural responses in the visual cortex of monkeys engaged in a delayed figure-ground detection task and analyzed the activity during the period of oculomotor preparation. We show that ≈100 ms before the onset of visually and memory-guided saccades neural activity in V1 becomes stronger where the strongest presaccadic responses are found at the location of the saccade target. In addition, in memory-guided saccades the strength of presaccadic activity shows a correlation with the onset of the saccade. These findings indicate that the primary visual cortex contains saccade-related responses and participates in visually guided oculomotor behavior. PMID:14970334

  17. Interrelationship of Primary Virus Replication, Level of Latency, and Time to Reactivation in the Trigeminal Ganglia of Latently Infected Mice

    PubMed Central

    Matundan, Harry H.; Mott, Kevin R.; Allen, Sariah J.; Wang, Shaohui; Bresee, Catherine J.; Ghiasi, Yasamin N.; Town, Terrence

    2016-01-01

    ABSTRACT We sought to determine the possibility of an interrelationship between primary virus replication in the eye, the level of viral DNA in the trigeminal ganglia (TG) during latency, and the amount of virus reactivation following ocular herpes simplex virus type 1 (HSV-1) infection. Mice were infected with virulent (McKrae) or avirulent (KOS and RE) strains of HSV-1, and virus titers in the eyes and TG during primary infection, level of viral gB DNA in TG on day 28 postinfection (p.i.), and virus reactivation on day 28 p.i. as measured by explant reactivation were calculated. Our results suggest that the avirulent strains of HSV-1, even after corneal scarification, had lower virus titers in the eye, had less latency in the TG, and took a longer time to reactivate than virulent strains of HSV-1. The time to explant reactivation of avirulent strains of HSV-1 was similar to that of the virulent LAT(−) McKrae-derived mutant. The viral dose with the McKrae strain of HSV-1 affected the level of viral DNA and time to explant reactivation. Overall, our results suggest that there is no absolute correlation between primary virus titer in the eye and TG and the level of viral DNA in latent TG and time to reactivation. IMPORTANCE Very little is known regarding the interrelationship between primary virus replication in the eye, the level of latency in TG, and the time to reactivate in the mouse model. This study was designed to answer these questions. Our results point to the absence of any correlation between the level of primary virus replication and the level of viral DNA during latency, and neither was an indicator of how rapidly the virus reactivated following explant TG-induced reactivation. PMID:27512072

  18. Duane retraction syndrome: causes, effects and management strategies

    PubMed Central

    Kekunnaya, Ramesh; Negalur, Mithila

    2017-01-01

    Duane retraction syndrome (DRS) is a congenital eye movement anomaly characterized by variable horizontal duction deficits, with narrowing of the palpebral fissure and globe retraction on attempted adduction, occasionally accompanied by upshoot or down-shoot. The etiopathogenesis of this condition can be explained by a spectrum of mechanical, innervational, neurologic and genetic abnormalities occurring independently or which influence each other giving rise to patterns of clinical presentations along with a complex set of ocular and systemic anomalies. Huber type I DRS is the most common form of DRS with an earlier presentation, while Huber type II is the least common presentation. Usually, patients with unilateral type I Duane syndrome have esotropia more frequently than exotropia, those with type II have exotropia and those with type III have esotropia and exotropia occurring equally common. Cases of bilateral DRS may have variable presentation depending upon the type of presentation in each eye. As regards its management, DRS classification based on primary position deviation as esotropic, exotropic or orthotropic is more relevant than Huber’s classification before planning surgery. Surgical approach to these patients is challenging and must be individualized based on the amount of ocular deviation, abnormal head position, associated globe retraction and overshoots. PMID:29133973

  19. Dermoscopy improves accuracy of primary care physicians to triage lesions suggestive of skin cancer.

    PubMed

    Argenziano, Giuseppe; Puig, Susana; Zalaudek, Iris; Sera, Francesco; Corona, Rosamaria; Alsina, Mercè; Barbato, Filomena; Carrera, Cristina; Ferrara, Gerardo; Guilabert, Antonio; Massi, Daniela; Moreno-Romero, Juan A; Muñoz-Santos, Carlos; Petrillo, Gianluca; Segura, Sonia; Soyer, H Peter; Zanchini, Renato; Malvehy, Josep

    2006-04-20

    Primary care physicians (PCPs) constitute an appropriate target for new interventions and educational campaigns designed to increase skin cancer screening and prevention. The aim of this randomized study was to determine whether the adjunct of dermoscopy to the standard clinical examination improves the accuracy of PCPs to triage lesions suggestive of skin cancer. PCPs in Barcelona, Spain, and Naples, Italy, were given a 1-day training course in skin cancer detection and dermoscopic evaluation, and were randomly assigned to the dermoscopy evaluation arm or naked-eye evaluation arm. During a 16-month period, 73 physicians evaluated 2,522 patients with skin lesions who attended their clinics and scored individual lesions as benign or suggestive of skin cancer. All patients were re-evaluated by expert dermatologists at clinics for pigmented lesions. Referral accuracy of both PCP groups was calculated by their scores, which were compared to those tabulated for dermatologists. Referral sensitivity, specificity, and positive and negative predictive values were 54.1%, 71.3%, 11.3%, and 95.8%, respectively, in the naked-eye arm, and 79.2%, 71.8%, 16.1%, and 98.1%, respectively, in the dermoscopy arm. Significant differences were found in terms of sensitivity and negative predictive value (P = .002 and P = .004, respectively). Histopathologic examination of equivocal lesions revealed 23 malignant skin tumors missed by PCPs performing naked-eye observation and only six by PCPs using dermoscopy (P = .002). The use of dermoscopy improves the ability of PCPs to triage lesions suggestive of skin cancer without increasing the number of unnecessary expert consultations.

  20. Modeling control of eye orientation in three dimensions. I. Role of muscle pulleys in determining saccadic trajectory.

    PubMed

    Raphan, T

    1998-05-01

    This study evaluates the effects of muscle axis shifts on the performance of a vector velocity-position integrator in the CNS. Earlier models of the oculomotor plant assumed that the muscle axes remained fixed relative to the head as the eye rotated into secondary and tertiary eye positions. Under this assumption, the vector integrator model generates torsional transients as the eye moves from secondary to tertiary positions of fixation. The torsional transient represents an eye movement response to a spatial mismatch between the torque axes that remain fixed in the head and the displacement plane that changes by half the angle of the change in eye orientation. When muscle axis shifts were incorporated into the model, the torque axes were closer to the displacement plane at each eye orientation throughout the trajectory, and torsional transients were reduced dramatically. Their size and dynamics were close to reported data. It was also shown that when the muscle torque axes were rotated by 50% of the eye rotation, there was no torsional transient and Listing's law was perfectly obeyed. When muscle torque axes rotated >50%, torsional transients reversed direction compared with what occurred for muscle axis shifts of <50%. The model indicates that Listing's law is implemented by the oculomotor plant subject to a two-dimensional command signal that is confined to the pitch-yaw plane, having zero torsion. Saccades that bring the eye to orientations outside Listing's plane could easily be corrected by a roll pulse that resets the roll state of the velocity-position integrator to zero. This would be a simple implementation of the corrective controller suggested by Van Opstal and colleagues. The model further indicates that muscle axis shifts together with the torque orientation relationship for tissue surrounding the eye and Newton's laws of motion form a sufficient plant model to explain saccadic trajectories and periods of fixation when driven by a vector command confined to the pitch-yaw plane. This implies that the velocity-position integrator is probably realized as a subtractive feedback vector integrator and not as a quaternion-based integrator that implements kinematic transformations to orient the eye.

  1. [Cyclorotation of the eye in wavefront-guided LASIK using a static eyetracker with iris recognition].

    PubMed

    Kohnen, T; Kühne, C; Cichocki, M; Strenger, A

    2007-01-01

    Centration of the ablation zone decisively influences the result of wavefront-guided LASIK. Cyclorotation of the eye occurs as the patient changes from the sitting position during aberrometry to the supine position during laser surgery and may lead to induction of lower and higher order aberrations. Twenty patients (40 eyes) underwent wavefront-guided LASIK (B&L 217z 100 excimer laser) with a static eyetracker driven by iris recognition (mean preoperative SE: -4.72+/-1.45 D; range: -1.63 to -7.00 D). The iris patterns of the patients' eyes were memorized during aberrometry and after flap creation. The mean absolute value of the measured cyclorotation was -1.5+/-4.2 degrees (range: -11.0 to 6.9 degrees ). The mean cyclorotation was 3.5+/-2.7 masculine (range: 0.1 to 11.0 degrees ). In 65% of all eyes cyclorotation was >2 masculine. A static eyetracker driven by iris recognition demonstrated that cyclorotation of up to 11 degrees may occur in myopic and myopic astigmatic eyes when changing from a sitting to a supine position. Use of static eyetrackers with iris recognition may provide a more precise positioning of the ablation profile as they detect and compensate cyclorotation.

  2. Seeing the world through rose-colored glasses: People who are happy and satisfied with life preferentially attend to positive stimuli.

    PubMed

    Raila, Hannah; Scholl, Brian J; Gruber, June

    2015-08-01

    Given the many benefits conferred by trait happiness and life satisfaction, a primary goal is to determine how these traits relate to underlying cognitive processes. For example, visual attention acts as a gateway to awareness, raising the question of whether happy and satisfied people attend to (and therefore see) the world differently. Previous work suggests that biases in selective attention are associated with both trait negativity and with positive affect states, but to our knowledge, no previous work has explored whether trait-happy individuals attend to the world differently. Here, we employed eye tracking as a continuous measure of sustained overt attention during passive viewing of displays containing positive and neutral photographs to determine whether selective attention to positive scenes is associated with measures of trait happiness and life satisfaction. Both trait measures were significantly correlated with selective attention for positive (vs. neutral) scenes, and this general pattern was robust across several types of positive stimuli (achievement, social, and primary reward), and not because of positive or negative state affect. Such effects were especially prominent during the later phases of sustained viewing. This suggests that people who are happy and satisfied with life may literally see the world in a more positive light, as if through rose-colored glasses. Future work should investigate the causal relationship between such attention biases and one's happiness and life satisfaction. (c) 2015 APA, all rights reserved).

  3. A MATLAB-based eye tracking control system using non-invasive helmet head restraint in the macaque.

    PubMed

    De Luna, Paolo; Mohamed Mustafar, Mohamed Faiz Bin; Rainer, Gregor

    2014-09-30

    Tracking eye position is vital for behavioral and neurophysiological investigations in systems and cognitive neuroscience. Infrared camera systems which are now available can be used for eye tracking without the need to surgically implant magnetic search coils. These systems are generally employed using rigid head fixation in monkeys, which maintains the eye in a constant position and facilitates eye tracking. We investigate the use of non-rigid head fixation using a helmet that constrains only general head orientation and allows some freedom of movement. We present a MATLAB software solution to gather and process eye position data, present visual stimuli, interact with various devices, provide experimenter feedback and store data for offline analysis. Our software solution achieves excellent timing performance due to the use of data streaming, instead of the traditionally employed data storage mode for processing analog eye position data. We present behavioral data from two monkeys, demonstrating that adequate performance levels can be achieved on a simple fixation paradigm and show how performance depends on parameters such as fixation window size. Our findings suggest that non-rigid head restraint can be employed for behavioral training and testing on a variety of gaze-dependent visual paradigms, reducing the need for rigid head restraint systems for some applications. While developed for macaque monkey, our system of course can work equally well for applications in human eye tracking where head constraint is undesirable. Copyright © 2014. Published by Elsevier B.V.

  4. Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes.

    PubMed

    Schaeffel, Frank

    2008-05-01

    Tilt and decentration of the natural crystalline lens affect optical quality of the foveal image. However, little is known about the distributions of these variables in healthy subjects with phakic eyes and about their correlations in both eyes. A simple, portable, easy-to-use, and partially automated device was developed to study lens tilt and decentration in both eyes of 11 healthy subjects with phakic eyes. The first, third, and fourth Purkinje images (P1, P3, P4) were visualized using a single infrared (IR) light-emitting diode (LED), a planar lens (F = 85 mm; f/number of 1.4), and an infrared sensitive analog video camera. Software was developed to mark pupil edges and positions of P1, P4, and P3 with the cursor of the computer mouse, for three different gaze positions, and an automated regression analysis determined the gaze position that superimposed the third and fourth Purkinje images, the gaze direction for which the lens was oriented perpendicularly to the axis of the IR LED. In this position, lens decentration was determined as the linear distance of the superimposed P3/P4 positions from the pupil center. Contrary to previous approaches, a short initial fixation of a green LED with known angular position calibrated the device as a gaze tracker, and no further positional information was necessary on fixation targets. Horizontal and vertical kappa, horizontal and vertical lens tilt, and vertical lens decentration were highly correlated in both eyes of the subjects, whereas horizontal decentration of the lens was not. There was a large variability of kappa (average horizontal kappa -1.63 degrees +/- 1.77 degrees [left eyes] and +2.07 degrees +/- 2.68 degrees [right eyes]; average vertical kappa +2.52 degrees +/- 1.30 degrees [left eyes] and +2.77 degrees +/- 1.65 degrees [right eyes]). Standard deviation from three repeated measurements ranged from 0.28 degrees to 0.51 degrees for kappa, 0.36 degrees to 0.91 degrees for horizontal lens tilt, and 0.36 degrees to 0.48 degrees for vertical lens tilt. Decentration was measured with standard deviations ranging from 0.02 mm to 0.05 mm. All lenses were found tilted to the temporal side with respect to the fixation axis (on average by 4.6 degrees ). They were also decentered downward with respect to the pupil center by approximately 0.3 mm. Lens tilts and positions could be conveniently measured with the described portable device, a video camera with a large lens. That the lenses were tilted to the temporal side in both eyes, even if corrected for kappa, was unexpected. That they were displaced downward with respect to the pupil center could be related to gravity.

  5. Figure-ground activity in primary visual cortex (V1) of the monkey matches the speed of behavioral response.

    PubMed

    Supèr, Hans; Spekreijse, Henk; Lamme, Victor A F

    2003-06-26

    To look at an object its position in the visual scene has to be localized and subsequently appropriate oculo-motor behavior needs to be initiated. This kind of behavior is largely controlled by the cortical executive system, such as the frontal eye field. In this report, we analyzed neural activity in the visual cortex in relation to oculo-motor behavior. We show that in a figure-ground detection task, the strength of late modulated activity in the primary visual cortex correlates with the saccade latency. We propose that this may indicate that the variability of reaction times in the detection of a visual stimulus is reflected in low-level visual areas as well as in high-level areas.

  6. Short-term adaptation of the VOR: non-retinal-slip error signals and saccade substitution

    NASA Technical Reports Server (NTRS)

    Eggers, Sscott D Z.; De Pennington, Nick; Walker, Mark F.; Shelhamer, Mark; Zee, David S.

    2003-01-01

    We studied short-term (30 min) adaptation of the vestibulo-ocular reflex (VOR) in five normal humans using a "position error" stimulus without retinal image motion. Both before and after adaptation a velocity gain (peak slow-phase eye velocity/peak head velocity) and a position gain (total eye movement during chair rotation/amplitude of chair motion) were measured in darkness using search coils. The vestibular stimulus was a brief ( approximately 700 ms), 15 degrees chair rotation in darkness (peak velocity 43 degrees /s). To elicit adaptation, a straight-ahead fixation target disappeared during chair movement and when the chair stopped the target reappeared at a new location in front of the subject for gain-decrease (x0) adaptation, or 10 degrees opposite to chair motion for gain-increase (x1.67) adaptation. This position-error stimulus was effective at inducing VOR adaptation, though for gain-increase adaptation the primary strategy was to substitute augmenting saccades during rotation while for gain-decrease adaptation both corrective saccades and a decrease in slow-phase velocity occurred. Finally, the presence of the position-error signal alone, at the end of head rotation, without any attempt to fix upon it, was not sufficient to induce adaptation. Adaptation did occur, however, if the subject did make a saccade to the target after head rotation, or even if the subject paid attention to the new location of the target without actually looking at it.

  7. A randomized trial of adding a plano lens to atropine for amblyopia.

    PubMed

    Wallace, David K; Lazar, Elizabeth L; Repka, Michael X; Holmes, Jonathan M; Kraker, Raymond T; Hoover, Darren L; Weise, Katherine K; Waters, Amy L; Rice, Melissa L; Peters, Robert J

    2015-02-01

    Some children have residual amblyopia after treatment with atropine eyedrops for amblyopia due to strabismus and/or anisometropia. We conducted a randomized clinical trial to evaluate the effectiveness of augmenting the effect of atropine by changing the lens over the fellow eye to plano in children with residual amblyopia. A total of 73 children 3 to <8 years of age (mean, 5.8 years) with stable residual amblyopia (range, 20/32 to 20/160, mean 20/63(+1)) were enrolled after at least 12 weeks of atropine treatment of the fellow eye. Participants were randomly assigned to continuing weekend atropine alone or wearing a plano lens over the fellow eye (while continuing atropine). The primary outcome was assessed at 10 weeks, and participants were followed until improvement ceased. At the 10-week primary outcome visit, amblyopic-eye visual acuity had improved an average of 1.1 lines with the plano lens and 0.6 lines with atropine only (difference adjusted for baseline visual acuity = + 0.5 line; 95% CI, -0.1 to +1.2). At the primary outcome or later visit when the best-measured visual acuity was observed, the mean amblyopic-eye improvement from baseline was 1.9 lines with the plano lens and 0.8 lines with atropine only. When amblyopic-eye visual acuity stops improving with atropine treatment, there may be a small benefit to augmenting atropine therapy with a plano lens over the fellow eye. However, the effect was not statistically significant, and the large confidence interval raises the possibility of no benefit or a benefit larger than we observed. A larger study would be necessary to get a more precise estimate of the treatment effect. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  8. Invasive liver abscess syndrome caused by Klebsiella pneumoniae with definite K2 serotyping in Japan: a case report.

    PubMed

    Seo, Ryota; Kudo, Daisuke; Gu, Yoshiaki; Yano, Hisakazu; Aoyagi, Tetsuji; Omura, Taku; Irino, Shigemi; Kaku, Mitsuo; Kushimoto, Shigeki

    2016-12-01

    Klebsiella pneumonia is a well-known human pathogen, and recently, a distinct invasive syndrome caused by K. pneumoniae serotypes K1 and K2 has been recognized in Southeast Asia. This syndrome is characterized by primary liver abscess and extrahepatic complications resulting from bacteremic dissemination. We report the first adult case of primary liver abscess caused by the definite K2 serotyped pathogen, with endogenous endophthalmitis in Japan. A 64-year-old woman was admitted to a nearby hospital for a high fever and diarrhea. She had visual loss of her right eye, renal dysfunction, and thrombocytopenia within 24 h from admission. She was transferred to our institution. On admission, she had no alteration of mental status and normal vital signs; however, she had almost complete ablepsia of the right eye. Laboratory data showed severe inflammation, liver dysfunction, thrombocytopenia, an increased serum creatinine level, and coagulopathy. Computed tomography showed a low density area in the right lobe of the liver. Invasive liver abscess syndrome probably caused by K. pneumonia was highly suspected and immediately administered broad-spectrum antibiotics for severe sepsis. Concurrently, endogenous endophthalmitis was diagnosed, and we performed vitrectomy on the day of admission. The blood culture showed K. pneumoniae infection. Percutaneous drainage of the liver abscess was also performed. Although she was discharged in a good general condition on day 22, she had complete ablepsia of the right eye. The K2A gene was detected by polymerase chain reaction (PCR), which is consistent with the K2 serotype. PCR was also positive for the virulence-associated gene rmpA. Final diagnosis was invasive liver abscess syndrome caused by K2 serotype K. pneumonia. Although the primary liver abscess caused by K. pneumoniae with a hypermucoviscous phenotype is infrequently reported outside Southeast Asia, physicians should recognize this syndrome, and appropriate diagnosis and treatment is essential for saving patients' lives and preserving organ function, especially for visual acuity.

  9. Treatment of Dry Eye Disease.

    PubMed

    Marshall, Leisa L; Roach, J Michael

    2016-02-01

    Review of the etiology, clinical manifestations, and treatment of dry eye disease (DED). Articles indexed in PubMed (National Library of Medicine), Iowa Drug Information Service (IDIS), and the Cochrane Reviews and Trials in the last 10 years using the key words "dry eye disease," "dry eye syndrome," "dry eye and treatment." Primary sources were used to locate additional resources. Sixty-eight publications were reviewed, and criteria supporting the primary objective were used to identify useful resources. The literature included practice guidelines, book chapters, review articles, original research articles, and product prescribing information for the etiology, clinical manifestations, diagnosis, and treatment of DED. DED is one of the most common ophthalmic disorders. Signs and symptoms of DED vary by patient, but may include ocular irritation, redness, itching, photosensitivity, visual blurring, mucous discharge, and decreased tear meniscus or break-up time. Symptoms improve with treatment, but the condition is not completely curable. Treatment includes reducing environmental causes, discontinuing medications that cause or worsen dry eye, and managing contributing ocular or systemic conditions. Most patients use nonprescription tear substitutes, and if these are not sufficient, other treatment is prescribed. These treatments include the ophthalmic anti-inflammatory agent cyclosporine, punctal occlusion, eye side shields, systemic cholinergic agents, and autologous serum tears. This article reviews the etiology, symptoms, and current therapy for DED.

  10. Biometric Factors Associated With Acute Primary Angle Closure: Comparison of the Affected and Fellow Eye.

    PubMed

    Atalay, Eray; Nongpiur, Monisha E; Baskaran, Mani; Sharma, Sourabh; Perera, Shamira A; Aung, Tin

    2016-10-01

    To compare ocular biometric and anterior segment parameters between the affected and fellow eye in subjects with acute primary angle closure (APAC). We evaluated 76 subjects with unilateral APAC who had undergone bilateral laser peripheral iridotomy before enrollment. Imaging was done using anterior segment optical coherence tomography and a customized software was used to measure the following: angle opening distance (AOD750); trabecular-iris space area (TISA750); iris thickness (IT750); iris curvature (ICURV); iris area (IAREA); anterior chamber depth; area and volume (ACD; ACA and ACV); anterior chamber width (ACW); anterior vault (ACD+LV); lens vault (LV); and pupil diameter (PD). We used A-scan ultrasonography to measure axial length (AL) and lens thickness (LT). Mean differences in ocular biometric and anterior segment parameters were assessed using linear mixed model adjusting for PD. A total of 53 subjects (36 females, 67.9%) with a mean age of 62.7 ± 8.1 years were analyzed after excluding 17 unanalyzable images in at least one eye. Affected eyes had shallower ACD, smaller ACA, ACV, anterior vault, TISA750, AOD750, and ICURV (all P < 0.05). Axial length, ACW, LV, LT, IAREA, and IT750 did not differ between the eyes. In the affected eyes, IT750 was significantly associated AOD750 (P < 0.05); whereas in the fellow eyes, IT750 and AL was predictive of AOD750 (all P < 0.05). Eyes with previous APAC had smaller anterior segment dimensions when compared with their fellow eyes. Iris thickness was the strongest predictor of angle width in both affected and fellow eyes.

  11. Quantitative measurement of eyestrain on 3D stereoscopic display considering the eye foveation model and edge information.

    PubMed

    Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung

    2014-05-15

    We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors.

  12. Hypothesized eye movements of neurolinguistic programming: a statistical artifact.

    PubMed

    Farmer, A; Rooney, R; Cunningham, J R

    1985-12-01

    Neurolinguistic programming's hypothesized eye-movements were measured independently from videotapes of 30 subjects, aged 15 to 76 yr., who were asked to recall visual pictures, recorded audio sounds, and textural objects. chi 2 indicated that subjects' responses were significantly different from those predicted. When chi 2 comparisons were weighted by number of eye positions assigned to each modality (3 visual, 3 auditory, 1 kinesthetic), subjects' responses did not differ significantly from the expected pattern. These data indicate that the eye-movement hypothesis may represent randomly occurring rather than sensory-modality-related positions.

  13. Eye Size and Set in Small-Bodied Fossil Primates: A Three-Dimensional Method.

    PubMed

    Rosenberger, Alfred L; Smith, Tim D; DeLeon, Valerie B; Burrows, Anne M; Schenck, Robert; Halenar, Lauren B

    2016-12-01

    We introduce a new method to geometrically reconstruct eye volume and placement in small-bodied primates based on the three-dimensional contour of the intraorbital surface. We validate it using seven species of living primates, with dry skulls and wet dissections, and test its application on seven species of Paleogene fossils of interest. The method performs well even when the orbit is damaged and incomplete, lacking the postorbital bar and represented only by the orbital floor. Eye volume is an important quantity for anatomic and metabolic reasons, which due to differences in eye set, or position within (or outside) the bony orbit, can be underestimated in living and fossil forms when calculated from aperture diameter. Our Ectopic Index quantifies how much the globe's volume protrudes anteriorly from the aperture. Lemur, Notharctus and Rooneyia resemble anthropoids, with deeply recessed eyes protruding 11%-13%. Galago and Tarsius are the other extreme, at 47%-56%. We argue that a laterally oriented aperture has little to do with line-of-sight in euprimates, as large ectopic eyes can position the cornea to enable a directly forward viewing axis, and soft tissue positions the eyes facing forward in megachiropteran bats, which have unenclosed, open eye sockets. The size and set of virtual eyes reconstructed from 3D cranial models confirm that eyes were large to hypertrophic in Hemiacodon, Necrolemur, Microchoerus, Pseudoloris and Shoshonius, but eye size in Rooneyia may have been underestimated by measuring the aperture, as in Aotus. Anat Rec, 299:1671-1689, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Instrument Display Visual Angles for Conventional Aircraft and the MQ-9 Ground Control Station

    NASA Technical Reports Server (NTRS)

    Kamine, Tovy Haber; Bendrick, Gregg A.

    2008-01-01

    Aircraft instrument panels should be designed such that primary displays are in optimal viewing location to minimize pilot perception and response time. Human Factors engineers define three zones (i.e. cones ) of visual location: 1) "Easy Eye Movement" (foveal vision); 2) "Maximum Eye Movement" (peripheral vision with saccades), and 3) "Head Movement (head movement required). Instrument display visual angles were measured to determine how well conventional aircraft (T-34, T-38, F- 15B, F-16XL, F/A-18A, U-2D, ER-2, King Air, G-III, B-52H, DC-10, B747-SCA) and the MQ-9 ground control station (GCS) complied with these standards, and how they compared with each other. Selected instrument parameters included: attitude, pitch, bank, power, airspeed, altitude, vertical speed, heading, turn rate, slip/skid, AOA, flight path, latitude, longitude, course, bearing, range and time. Vertical and horizontal visual angles for each component were measured from the pilot s eye position in each system. The vertical visual angles of displays in conventional aircraft lay within the cone of "Easy Eye Movement" for all but three of the parameters measured, and almost all of the horizontal visual angles fell within this range. All conventional vertical and horizontal visual angles lay within the cone of Maximum Eye Movement. However, most instrument vertical visual angles of the MQ-9 GCS lay outside the cone of Easy Eye Movement, though all were within the cone of Maximum Eye Movement. All the horizontal visual angles for the MQ-9 GCS were within the cone of "Easy Eye Movement". Most instrument displays in conventional aircraft lay within the cone of Easy Eye Movement, though mission-critical instruments sometimes displaced less important instruments outside this area. Many of the MQ-9 GCS systems lay outside this area. Specific training for MQ-9 pilots may be needed to avoid increased response time and potential error during flight. The learning objectives include: 1) Know three physiologic cones of eye/head movement; 2) Understand how instrument displays comply with these design principles in conventional aircraft and an uninhabited aerial vehicle system. Which of the following is NOT a recognized physiologic principle of instrument display design? Cone of Easy Eye Movement 2) Cone of Binocular Eye Movement 3) Cone of Maximum Eye Movement 4) Cone of Head Movement 5) None of the above. Answer: # 2) Cone of Binocular Eye Movement

  15. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    PubMed

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P < .001) and lens position (r = 0.371, P < .001), but negatively correlated with lens thickness (r = -0.262, P < .001). Eyes with vaults of less than 250 µm had shallower anterior chambers, thicker lenses, and smaller lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P < .001). Eyes with both anterior chamber depth less than 3.1 mm and lens position less than 5.1 mm had greatly reduced vaults (P < .001). The crystalline lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  16. Dry eyes and corneal sensation after laser in situ keratomileusis with femtosecond laser flap creation Effect of hinge position, hinge angle, and flap thickness.

    PubMed

    Mian, Shahzad I; Li, Amy Y; Dutta, Satavisha; Musch, David C; Shtein, Roni M

    2009-12-01

    To determine whether corneal sensation and dry-eye signs and symptoms after myopic laser in situ keratomileusis (LASIK) surgery with a femtosecond laser are affected by varying hinge position, hinge angle, or flap thickness. University-based academic practice, Ann Arbor, Michigan, USA. This prospective randomized contralateral-eye study evaluated eyes after bilateral myopic LASIK with a femtosecond laser (IntraLase). Superior and temporal hinge positions, 45-degree and 90-degree hinge angles, and 100 microm and 130 microm corneal flap thicknesses were compared. Postoperative follow-up at 1 week and 1, 3, 6, and 12 months included central Cochet-Bonnet esthesiometry, the Ocular Surface Disease Index questionnaire, a Schirmer test with anesthesia, tear breakup time (TBUT), corneal fluorescein staining, and conjunctival lissamine green staining. The study evaluated 190 consecutive eyes (95 patients). Corneal sensation was reduced at all postoperative visits, with improvement over 12 months (P<.001). There was no difference in corneal sensation between the different hinge positions, angles, or flap thicknesses at any time point. The overall ocular surface disease index score was increased at 1 week, 1 month, and 3 months (P<.0001, P<.0001, and P = .046, respectively). The percentage of patients with a TBUT longer than 10 seconds was significantly lower at 1 week and 1 month (P<.0001). Dry-eye syndrome after myopic LASIK with a femtosecond laser was mild and improved after 3 months. Corneal flap hinge position, hinge angle, and thickness had no effect on corneal sensation or dry-eye syndrome.

  17. Peripheral Refraction, Peripheral Eye Length, and Retinal Shape in Myopia.

    PubMed

    Verkicharla, Pavan K; Suheimat, Marwan; Schmid, Katrina L; Atchison, David A

    2016-09-01

    To investigate how peripheral refraction and peripheral eye length are related to retinal shape. Relative peripheral refraction (RPR) and relative peripheral eye length (RPEL) were determined in 36 young adults (M +0.75D to -5.25D) along horizontal and vertical visual field meridians out to ±35° and ±30°, respectively. Retinal shape was determined in terms of vertex radius of curvature Rv, asphericity Q, and equivalent radius of curvature REq using a partial coherence interferometry method involving peripheral eye lengths and model eye raytracing. Second-order polynomial fits were applied to RPR and RPEL as functions of visual field position. Linear regressions were determined for the fits' second order coefficients and for retinal shape estimates as functions of central spherical refraction. Linear regressions investigated relationships of RPR and RPEL with retinal shape estimates. Peripheral refraction, peripheral eye lengths, and retinal shapes were significantly affected by meridian and refraction. More positive (hyperopic) relative peripheral refraction, more negative RPELs, and steeper retinas were found along the horizontal than along the vertical meridian and in myopes than in emmetropes. RPR and RPEL, as represented by their second-order fit coefficients, correlated significantly with retinal shape represented by REq. Effects of meridian and refraction on RPR and RPEL patterns are consistent with effects on retinal shape. Patterns derived from one of these predict the others: more positive (hyperopic) RPR predicts more negative RPEL and steeper retinas, more negative RPEL predicts more positive relative peripheral refraction and steeper retinas, and steeper retinas derived from peripheral eye lengths predict more positive RPR.

  18. Frames of reference for gaze saccades evoked during stimulation of lateral intraparietal cortex.

    PubMed

    Constantin, A G; Wang, H; Martinez-Trujillo, J C; Crawford, J D

    2007-08-01

    Previous studies suggest that stimulation of lateral intraparietal cortex (LIP) evokes saccadic eye movements toward eye- or head-fixed goals, whereas most single-unit studies suggest that LIP uses an eye-fixed frame with eye-position modulations. The goal of our study was to determine the reference frame for gaze shifts evoked during LIP stimulation in head-unrestrained monkeys. Two macaques (M1 and M2) were implanted with recording chambers over the right intraparietal sulcus and with search coils for recording three-dimensional eye and head movements. The LIP region was microstimulated using pulse trains of 300 Hz, 100-150 microA, and 200 ms. Eighty-five putative LIP sites in M1 and 194 putative sites in M2 were used in our quantitative analysis throughout this study. Average amplitude of the stimulation-evoked gaze shifts was 8.67 degrees for M1 and 7.97 degrees for M2 with very small head movements. When these gaze-shift trajectories were rotated into three coordinate frames (eye, head, and body), gaze endpoint distribution for all sites was most convergent to a common point when plotted in eye coordinates. Across all sites, the eye-centered model provided a significantly better fit compared with the head, body, or fixed-vector models (where the latter model signifies no modulation of the gaze trajectory as a function of initial gaze position). Moreover, the probability of evoking a gaze shift from any one particular position was modulated by the current gaze direction (independent of saccade direction). These results provide causal evidence that the motor commands from LIP encode gaze command in eye-fixed coordinates but are also subtly modulated by initial gaze position.

  19. Glaucoma-related adverse events in the first five years after unilateral cataract removal in the Infant Aphakia Treatment Study

    PubMed Central

    Freedman, Sharon F.; Lynn, Michael J.; Beck, Allen D.; Bothun, Erick D.; Orge, Faruk H.; Lambert, Scott R.

    2015-01-01

    Importance Glaucoma-related adverse events constitute major sight-threatening complications of cataract removal in infancy, yet their relationship to aphakia versus primary intraocular lens (IOL) implantation remains unsettled. Objective To identify and characterize cases of glaucoma and glaucoma-related adverse events (glaucoma+glaucoma suspect) among children in the Infant Aphakia Treatment Study (IATS) by the age of five years. Design, Setting, and Participants A multicenter randomized controlled trial of 114 infants with unilateral congenital cataract who were between age 1–6 months at surgery. Interventions Participants were randomized at cataract surgery to either primary IOL, or no IOL implantation (contact lens [CL]). Standardized definitions of glaucoma and glaucoma suspect were created for IATS and applied for surveillance and diagnosis. Main Outcome Measures Development of glaucoma and glaucoma+glaucoma suspect in operated eyes up to age five years, plus intraocular pressure, visual acuity, and axial length at age five years. Results Product limit estimates of the risk of glaucoma and glaucoma+glaucoma suspect at 4.8 years after surgery were 17% (95%CI=11%–25%) and 31% (95%CI=24%–41%), respectively. The CL and IOL groups were not significantly different for either outcome: glaucoma (hazard ratio(HR)=0.8[95%CI=0.3–2.0],p=0.62); glaucoma+glaucoma suspect: (HR=1.3[95%CI=0.6–2.5],p=0.58). Younger (versus older) age at surgery conferred increased risk of glaucoma (26% versus 9%, respectively at 4.8 years after surgery (HR=3.2[95%CI=1.2–8.3]), and smaller (versus larger) corneal diameter showed increased risk for glaucoma+glaucoma suspect (HR=2.5[95%CI=1.3–5.0]). Age and corneal diameter were significantly positively correlated. Glaucoma was predominantly open angle (19/20 cases, 95%), most eyes received medication (19/20, 95%), and 8/20 (40%) eyes had surgery. Conclusions and Relevance These results suggest that glaucoma-related adverse events are common and increase between one and five years in infants after unilateral cataract removal at 1–6 months of age; primary IOL placement does not mitigate their risk, but surgery at a younger age increases the risk. Longer follow-up of these children may further characterize risk factors, long-term outcomes, potential differences between eyes having primary IOL vs. aphakia, and optimal timing of unilateral congenital cataract removal. PMID:25996491

  20. Radioallergosorbent testing for penicillin allergy in family practice.

    PubMed Central

    Worrall, G J; Hull, C; Briffett, E

    1994-01-01

    OBJECTIVES: To determine (a) the prevalence of patients supposedly allergic to penicillin who have a positive radioallergosorbent test (RAST) result for penicillin G or V and (b) the predictive power of family physicians' clinical judgement that a patient who is supposedly allergic to penicillin will have a positive RAST result. DESIGN: Prospective multicentre cross-sectional observational study. SETTING: Eleven primary care practices in Newfoundland; 10 were in a rural setting. PATIENTS: Of 110 consecutive adult patients with a supposed allergy to penicillin 97 agreed to participate in the study; 92 underwent RAST. INTERVENTIONS: Patients helped physicians complete a questionnaire and had a venous blood sample taken for the RAST. Physicians examined the clinical history and judged whether the patient was likely to have a positive RAST result. MEAN OUTCOME MEASURES: Rates of positive and negative RAST results for penicillin V and G. RESULTS: Of the 92 patients 8 had a positive RAST result and 84 a negative one. The positive predictive power of a "good" clinical history (e.g., urticaria, swollen eyes, tongue or lips, or an anaphylactic reaction witnessed by a physician) was low (10%); the negative predictive power of a "poor" clinical history (e.g., nausea, vomiting, diarrhea, fever, nonspecific rash or fainting) was 92%. CONCLUSIONS: Less than 10% of primary care patients with a supposed allergy to penicillin will have a positive RAST result. In addition, physicians' predictions of allergy in such patients are imprecise. PMID:8275407

  1. [Laser treatment for retinopathy of prematurity in neonatal intensive care units. Premature Eye Rescue Program].

    PubMed

    Maka, Erika; Imre, László; Somogyvári, Zsolt; Németh, János

    2015-02-01

    Retinopathy of prematurity is a leading cause of childhood blindness around the world. The Department of Ophthalmology at the Semmelweis University and the Peter Cerny Neonatal Emergency and Ambulance Service started an innovative Premature Eye Rescue Program to reduce the non-essential transport of premature babies suffering from retinopathy of prematurity. During the first 5 years 186 eyes of 93 premature babies were treated at the bedside with stage 3 retinopathy of prematurity in the primary hospitals. In this first 5-years period the authors reduced the number of transports of premature babies for laser treatment; 93 children avoided the unnecessary transport, saving altogether a distance of 21,930 kilometers for children, as well as the ambulance service. The Premature Eye Rescue Program offers a good and effective alternative for treatment of retinopathy in the primary hospitals. The authors propose the national extension of this program.

  2. A case of double depressor palsy followed by pursuit deficit due to sequential infarction in bilateral thalamus and right medial superior temporal area.

    PubMed

    Kim, Su Jin; Yeom, Myeong In; Lee, Seung Uk

    2017-12-01

    We present a unique case of a patient who suffered two rare events affecting the supranuclear control, first of the vertical and second of the horizontal eye movements. The first event involved bilateral thalamic infarcts that resulted in double depressor palsy. The second event occurred 1 year later and it involved supranuclear control of horizontal eye movements creating pursuit deficit. A 47-year-old male presented with complaints of diplopia upon awakening. He had atrial fibrillation, mitral valve regurgitation, aortic valve regurgitation, and a history of spleen infarction 1 year ago. His right eye was hypertrophic and right eye downgaze was limited unilaterally of equal degree in adduction and abduction. The patient was diagnosed with double depressor palsy of the right eye. Magnetic resonance imaging (MRI) of the brain showed an old infarction of the left thalamus, and diffusion MRI showed acute infarction of the right thalamus. The patient's daily warfarin dose was 2 mg and it was increased to 5 mg with cilostazol 75 mg twice a day. Seven weeks later, the patient's ocular movement revealed near normal muscle action, and subjectively, the patient was diplopia free. At follow-up 12 months later, the patient revisited the hospital because of sudden onset of blurred vision on right gaze. He was observed to have smooth pursuit deficit to the right side, and orthophoric position of the eyes in primary gaze. MRI of the brain showed an acute infarction in the right medial superior temporal area. The patient experienced very rare abnormal eyeball movements twice. This case highlights the importance of evaluating vertical movement of the eyes and vascular supplies when patients present with depressor deficit and supports the theory of a supranuclear function in patients who present with pursuit deficit.

  3. Longitudinal changes of angle configuration in primary angle-closure suspects: the Zhongshan Angle-Closure Prevention Trial.

    PubMed

    Jiang, Yuzhen; Chang, Dolly S; Zhu, Haogang; Khawaja, Anthony P; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M; He, Mingguang; Friedman, David S; Foster, Paul J

    2014-09-01

    To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Longitudinal cohort study. Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (P<0.001 for all variables). Between 2 weeks and 18 months after LPI, a significant decrease in angle width was observed over time in treated eyes (P<0.001 for all variables), although the change over the first 5.5 months was not statistically significant for angle width measured under gonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8-1.6) in treated eyes and 1.6°/year (95% CI, 1.3-2.0) in untreated eyes (P<0.001). Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the same time period. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Computational Model of the Eye for Primary and Secondary Blast Trauma

    DTIC Science & Technology

    2015-10-01

    inflicted closed eye injuries with features similar to those seen in patients with ocular blast trauma. Alphonse et al. [16] studied the effect of low...Kemper, V. Alphonse , C. McNally, I. Herring, P. Brown, J. Stitzel, and S. Duma. Response of Porcine Eyes to Blast Overpressure: Effects of Overpressure...that induces closed globe anterior and posterior pole damage. Experimental eye research, 99:63–70, 2012. [16] V. D. Alphonse , A. R. Kemper, B. T. Strom

  5. Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology.

    PubMed

    Principi, Sara; Ginjaume, Mercè; Duch, Maria Amor; Sánchez, Roberto M; Fernández, Jose M; Vano, Eliseo

    2015-04-01

    The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y(-1) averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in order to have a good estimate of the eye lens dose during interventional procedures. Measurements were performed with an X-ray system Philips Allura FD-10, using a PMMA phantom to simulate the patient scattered radiation and a Rando phantom to simulate the cardiologist. Thermoluminescence (TL) whole-body and TL eye lens dosemeters together with Philips DoseAware active dosemeters were located on different positions of the Rando phantom to estimate the eye lens dose in typical cardiology procedures. The results show that, for the studied conditions, any of the analysed dosemeter positions are suitable for eye lens dose assessment. However, the centre of the thyroid collar and the left ear position provide a better estimate. Furthermore, in practice, improper use of the ceiling-suspended screen can produce partial protection of some parts of the body, and thus large differences between the measured doses and the actual exposure of the eye could arise if the dosemeter is not situated close to the eye. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Optical modeling of a corneal inlay in real eyes to increase depth of focus: optimum centration and residual defocus.

    PubMed

    Tabernero, Juan; Artal, Pablo

    2012-02-01

    To determine the optimum position to center a small-aperture corneal inlay and the effect of residual defocus in the surgical eye to maximize depth of focus. Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain. Cohort study. Personalized eye models were built using actual data (corneal topography, eye length, ocular aberrations, and eye alignment). A small aperture 1.6 mm in diameter was placed at the corneal plane in each model. The monochromatic and polychromatic Strehl ratios were calculated as a function of the pinhole position. Different residual defocus values were also incorporated into the models, and the through-focus Strehl ratios were calculated. Sixteen eye models were built. For most subjects, the optimum location of the aperture for distance vision was close to the corneal reflex position. For a given optimized centration of the aperture, the best compromise of depth of focus was obtained when the eyes had some residual myopic defocus (range -0.75 to -1.00 diopter [D]). Strehl ratio values were over 0.1 for far distance, which led to visual acuities better than 20/20. The depth of focus was 2.50 D with a mean near visual acuity of Jaeger 1 or better. In eyes with little astigmatism and aberrations, the optimum centration of the small aperture was near the corneal reflex position. To improve optical outcomes with the inlay, some small residual myopia and correction of corneal astigmatism might be required. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Acquired simulated brown syndrome following surgical repair of medial orbital wall fracture.

    PubMed

    Hwang, Jong-uk; Lim, Hyun Taek

    2005-03-01

    Simulated Brown syndrome is a term applied to a myriad of disorders that cause a Brown syndrome-like motility. We encountered a case of acquired simulated Brown syndrome in a 41-year-old man following surgical repair of fractures of both medial orbital walls. He suffered from diplopia in primary gaze, associated with hypotropia of the affected eye. We performed an ipsilateral recession of the left inferior rectus muscle as a single-stage intraoperative adjustment procedure under topical anesthesia, rather than the direct approach to the superior oblique tendon. Postoperatively, the patient was asymptomatic in all diagnostic gaze positions.

  8. Outcomes following acute primary angle closure in an Asian population.

    PubMed

    Tan, Anna M; Loon, Seng C; Chew, Paul T K

    2009-07-01

    Data regarding development of primary angle closure glaucoma (PACG) following acute primary angle closure (APAC) is conflicting. This study looks at outcomes after an APAC episode with a secondary aim to identify any risk factors that could predict progression to PACG. This is a retrospective review of the charts of consecutive patients who were diagnosed with APAC from December 2003 to June 2006. All were treated in a standard manner with initial intensive medical therapy or laser iridoplasty followed by early laser peripheral iridotomy within 24 h of presentation. Forty-two eyes of 41 patients were analysed. The mean follow-up period was 27.3 +/- 16.2 months. Nine eyes (21.4%) developed an increase in intraocular pressure (IOP) within a mean of 11.9 months (median 5 months) after resolution of APAC. Eight eyes went on to have trabeculectomy or glaucoma drainage device. At final follow up, the mean IOP of attack eye was 13.3 +/- 2.92 mmHg. None of the eyes, including those that underwent surgery, required topical medication to control IOP. Thirty-eight eyes (90.5%) have BCVA of 6/6 to 6/12. The duration of symptoms before presentation (P = 0.00) and duration taken to abort the acute attack (P = 0.01) were found to be significantly associated with development of PACG. The results of this study suggest that outcomes following successful treatment of APAC may not be as poor as described previously. Early aggressive management of the acute episode may have a role to play in preventing development of PACG after APAC.

  9. Cost effectiveness analysis of a visual screening program for primary school children in Thailand.

    PubMed

    Tengtrisorn, Supaporn; Sangsupawanitch, Pasuree; Chansawang, Wannee

    2009-08-01

    To analyze the cost-effectiveness of a visual screening program for primary school children in southern Thailand. The visual acuity of 1900 primary school children from 11 schools in southern Thailand was assessed using the Snellen chart, Hirschberg test, an eye examination by penlight, and observation of the red reflex by direct ophthalmoscope, between April 2006 and March 2007. Children with visual acuity of < 20/40 or an abnormal observation in either eye were referred for further eye examination and refraction measurement, at which time they were categorized, according to the severity of the eye condition(s). A cost analysis was then performed for various severity-of-condition groupings. One hundred sixty eight children (8.8%) were found with referable problems, of which 122 parents signed a consent formforfurther testing. The mean age was 8.7 years (range 6-12 years). One hundred seven of the 122 subjects (87.7%) were considered to have a refractive error with or without one or more other eye conditions. The mean direct cost for visual screening by the assistant researcher, not including project management and traveling expenses, was 14.9 Baht per student (approximately 0.5 USD, 0.3 Euro). For nationwide implementation, the per head expenditure for children with treatable problems would be 1018.4 Baht if children with mild, moderate and severe abnormal eye conditions were targeted, and increased to 2270.1 Baht if only children with moderate and severe conditions were targeted The results of the present study indicate that this visual screening program is efficient and useful for preliminary school children in Thailand.

  10. Topical dobesilate eye drops for ophthalmic primary pterygium

    PubMed Central

    Cuevas, Pedro; Outeiriño, Luis A; Angulo, Javier; Giménez-Gallego, Guillermo

    2012-01-01

    Selective inhibition of fibroblast growth factor and vascular endothelial growth factor signalling pathways is effective in causing regression of pterygia. Prompt regression of fibrovascular mass and conjunctival angiogenesis was documented 2 weeks after topical administration of dobesilate eye drops twice daily. At 3-month follow-up, no recurrence was seen and no ocular irritation and burning were noted. The authors believe that this is the first known successful use of topical dobesilate in primary pterygium. PMID:22605609

  11. Mosaic: a position-effect variegation eye-color mutant in the mosquito Anopheles gambiae.

    PubMed

    Benedict, M Q; McNitt, L M; Cornel, A J; Collins, F H

    2000-01-01

    The Mosaic (Mos) mutation, isolated in the F1 of 60Co-irradiated mosquitoes, confers variegated eye color to third and fourth instar larvae, pupae, and adults of the mosquito Anopheles gambiae. Mos is recessive in wild pink eye (p+) individuals, but is dominant and confers areas of wild-type pigment in mutant pink eye backgrounds. Mos is located 14.4 cM from pink eye on the X chromosome and is associated with a duplication of division 2B euchromatin that has been inserted into division 6 heterochromatin. Various combinations of Mos, pink eye alleles, and the autosomal mutation red eye were produced. In all cases, the darker pigmented regions of the eye in Mos individuals show the phenotypic interactions expected if the phenotype of those regions is due to expression of a p+ allele. Expression of Mos is suppressed by rearing larvae at 32 degrees C relative to 22 degrees C. All of these characteristics are consistent with Mos being a duplicated wild copy of the pink eye gene undergoing position-effect variegation.

  12. Liquid nitrogen cryotherapy for surface eye disease (an AOS thesis).

    PubMed

    Fraunfelder, Frederick Web

    2008-01-01

    To evaluate the effects of new treatments with liquid nitrogen cryotherapy on some external eye conditions. In this retrospective case study, 6 separate series from a single tertiary care referral center practice are described. Liquid nitrogen cryotherapy was used to treat conjunctival amyloidosis, primary pterygia, recurrent pterygia, advancing wavelike epitheliopathy (AWLE), superior limbic keratoconjunctivitis (SLK), and palpebral vernal keratoconjunctivitis (VKC). The main outcome measure was the resolution of the disease process after treatment. Four patients with primary localized conjunctival amyloidosis were treated with liquid nitrogen cryotherapy. Two of them had recurrence of the amyloidosis, which cleared with subsequent treatment. Eighteen patients with primary pterygia had excision and cryotherapy with 1 recurrence. Of 6 subjects who presented with recurrent pterygia, 4 had a second recurrence after excision and cryotherapy. In 5 patients with AWLE, the condition resolved within 2 weeks without recurrence or the need for subsequent cryotherapy. Four patients with SLK were treated with liquid nitrogen cryotherapy. Disease recurred in 2 patients and 3 of 7 eyes, although subsequent cryotherapy eradicated SLK in all cases. Two patients and 3 eyelids with palpebral VKC were treated with liquid nitrogen cryotherapy. VKC recurred in all cases. Liquid nitrogen cryotherapy to the surface of the eye is effective in treating AWLE, and SLK. Excision followed by cryotherapy is successful in treating conjunctival amyloidosis and primary pterygia Liquid nitrogen cryotherapy is unsuccessful in the treatment of recurrent pterygia and VKC.

  13. SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omar, A; Marteinsdottir, M; Kadesjo, N

    Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due tomore » protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.« less

  14. Biometric Differences between Unilateral Chronic Primary Angle Closure Glaucoma and Fellow Non-Glaucomatous Eyes.

    PubMed

    Wang, Wei; Li, Xinyi; Chen, Shida; Huang, Wenbin; Zhang, Xiulan

    2017-11-29

    To compare biometric differences between eyes with unilateral chronic primary angle-closure glaucoma (PACG) and fellow non-glaucomatous eyes in the same patient. Clinical data and imaging records of 17 patients with unilateral PACG were retrospectively reviewed. The fellow eyes with primary angle-closure (PAC) or primary angle-closure suspected (PACS) were grouped in Group 1. The PACG eyes were set as Group 2. The biometric parameters of both eyes were measured by IOL-Master, anterior segment optical coherence tomography (AS-OCT), and swept source OCT. The iris area in Group 1 was significantly thicker than that in Group 2 (1.590 ± 0.267 versus 1.365 ± 0.352, P = 0.016). Choroidal thickness in the macular region was thicker in Group 1 than in Group 2, with statistical significance at inner temporal grid (282.7 ± 121.1 versus 191.6 ± 90.3, P = 0.036), central field (297.4 ± 130.6 versus 200.1 ± 96.3, P = 0.029), inner nasal grid (283.1 ± 128.3 versus 194.8 ± 91.8, P = 0.040), and average value (265.3 ± 105.6 versus 191.1 ± 87.0, P = 0.049). Group 1 also had thicker peripapillary choroidal thickness at 1 o'clock (141.4 ± 68.4 versus 101.8 ± 39.0, P = 0.025) and 12 o'clock (141.5 ± 82.3 versus 104.5 ± 44.6, P = 0.037) compared to Group 2. The multivariate logistic regression analyses showed that only intraocular pressure was independently associated with PACG and explained 58.3% variance of PACG. In unilateral PACG, there was significant inter-eye difference in anterior and posterior segment parameters. Longitudinal comparisons are required to further understand the differences in pathology of angle closures.

  15. Changes in ocular biometry and anterior chamber parameters after pharmacologic mydriasis and peripheral iridotomy in primary angle closure suspects.

    PubMed

    Razeghinejad, Mohammad Reza; Lashkarizadeh, Hamid; Nowroozzadeh, Mohammad Hossein; Yazdanmehr, Mohammad

    2016-01-01

    The aim of this study was to evaluate the effects of pharmacologic mydriasis and Peripheral Iridotomy (PI) on ocular biometry and anterior chamber parameters in primary angle closure suspects. In this prospective interventional case series, 21 primary angle closure suspects were enrolled. Intraocular pressure, refraction, ocular biometry (Lenstar, LS900), and anterior chamber parameters (Pentacam HR) were measured at four occasions: before PI (before and after mydriasis with phenylephrine) and two weeks after PI (before and after mydriasis). The study was conducted on both eyes and only one eye per patient, in random, was included in the analysis. The mean age of the participants was 60±7 years and 17 (81%) were female. There were no significant differences in intraocular pressure, refraction, keratometry, biometric and anterior chamber parameters between groups, except for anterior chamber volume, which showed increments with PI and mydriasis. The corresponding values for anterior chamber volume were as follows: 88.2±13.7mm(3) before PI, undilated; 106.3±18.8 before PI, dilated; 99.0±14.6 after PI, undilated, and 107.4±16.5 after PI, dilated (P<0.001). This study showed no change in the ocular biometric and anterior chamber parameters including iridocorneal angle after PI and/or pharmacologic mydriasis except for increments in anterior chamber volume. This factor has the potential to be used as a numerical proxy for iris position in evaluating and monitoring patients with primary angle closure suspects after PI. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  16. Role of Host-Defence Peptides in Eye Diseases

    PubMed Central

    Kolar, Satya S.; McDermott, Alison M.

    2013-01-01

    The eye and its associated tissues including the lacrimal system and lids have evolved several defence mechanisms to prevent microbial invasion. Included among this armory are several host-defence peptides. These multifunctional molecules are being studied not only for their endogenous antimicrobial properties but also for their potential therapeutic effects. Here the current knowledge of host-defence peptide expression in the eye will be summarized. The role of these peptides in eye disease will be discussed with the primary focus being on infectious keratitis, inflammatory conditions including dry eye and wound healing. Finally the potential of using host-defence peptides and their mimetics/derivatives for the treatment and prevention of eye diseases is addressed. PMID:21584809

  17. The Importance of Minor Salivary Gland Biopsy in Sjögren Syndrome Diagnosis and the Clinicopathological Correlation.

    PubMed

    Serin, Gürdeniz; Karabulut, Gonca; Kabasakal, Yasemin; Kandiloğlu, Gülşen; Akalin, Taner

    2016-01-01

    Minor salivary gland biopsy is one of the objective tests used in the diagnosis of Sjögren syndrome. The aim of our study was to compare the clinical and laboratory data of primary and secondary Sjögren syndrome cases with a lymphocyte score 3 and 4 in the minor salivary gland biopsy. Data from a total of 2346 consecutive minor salivary gland biopsies were retrospectively evaluated in this study. Clinical and autoantibody characteristics of 367 cases with lymphocyte score 3 or 4 and diagnosed with primary or secondary Sjögren syndrome were compared. There was no difference between lymphocyte score 3 and 4 primary Sjögren syndrome patients in terms of dry mouth, dry eye symptoms and Schirmer test results but Anti-Ro and Antinuclear Antibody positivity was statistically significantly higher in cases with lymphocyte score 4 (p= 0.025, p= 0.001). Anti-Ro test results were also found to be statistically significantly higher in secondary Sjögren syndrome patients with lymphocyte score 4 (p= 0.048). In this study, the high proportion of cases with negative autoantibody but positive lymphocyte score is significant in terms of showing the contribution of minor salivary gland biopsy to Sjögren syndrome diagnosis. Lymphocyte score 3 and 4 cases were found to have similar clinical findings but a difference regarding antibody positivity in primary Sjögren syndrome. We believe that cases with lymphocyte score 4 may be Sjögren syndrome cases whose clinical manifestations are relatively established and higher autoantibody levels are therefore found.

  18. Distinct eye movement patterns enhance dynamic visual acuity.

    PubMed

    Palidis, Dimitrios J; Wyder-Hodge, Pearson A; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics-eye latency, acceleration, velocity gain, position error-and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns-minimizing eye position error, tracking smoothly, and inhibiting reverse saccades-were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA.

  19. Distinct eye movement patterns enhance dynamic visual acuity

    PubMed Central

    Palidis, Dimitrios J.; Wyder-Hodge, Pearson A.; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics—eye latency, acceleration, velocity gain, position error—and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns—minimizing eye position error, tracking smoothly, and inhibiting reverse saccades—were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA. PMID:28187157

  20. Geometric adjustments to account for eye eccentricity in processing horizontal and vertical eye and head movement data

    NASA Technical Reports Server (NTRS)

    Huebner, W. P.; Paloski, W. H.; Reschke, M. F.; Bloomberg, J. J.

    1995-01-01

    Neglecting the eccentric position of the eyes in the head can lead to erroneous interpretation of ocular motor data, particularly for near targets. We discuss the geometric effects that eye eccentricity has on the processing of target-directed eye and head movement data, and we highlight two approaches to processing and interpreting such data. The first approach involves determining the true position of the target with respect to the location of the eyes in space for evaluating the efficacy of gaze, and it allows calculation of retinal error directly from measured eye, head, and target data. The second approach effectively eliminates eye eccentricity effects by adjusting measured eye movement data to yield equivalent responses relative to a specified reference location (such as the center of head rotation). This latter technique can be used to standardize measured eye movement signals, enabling waveforms collected under different experimental conditions to be directly compared, both with the measured target signals and with each other. Mathematical relationships describing these approaches are presented for horizontal and vertical rotations, for both tangential and circumferential display screens, and efforts are made to describe the sensitivity of parameter variations on the calculated results.

  1. Eye gaze tracking for endoscopic camera positioning: an application of a hardware/software interface developed to automate Aesop.

    PubMed

    Ali, S M; Reisner, L A; King, B; Cao, A; Auner, G; Klein, M; Pandya, A K

    2008-01-01

    A redesigned motion control system for the medical robot Aesop allows automating and programming its movements. An IR eye tracking system has been integrated with this control interface to implement an intelligent, autonomous eye gaze-based laparoscopic positioning system. A laparoscopic camera held by Aesop can be moved based on the data from the eye tracking interface to keep the user's gaze point region at the center of a video feedback monitor. This system setup provides autonomous camera control that works around the surgeon, providing an optimal robotic camera platform.

  2. Progression of visual field in patients with primary open-angle glaucoma - ProgF study 1.

    PubMed

    Aptel, Florent; Aryal-Charles, Nishal; Giraud, Jean-Marie; El Chehab, Hussam; Delbarre, Maxime; Chiquet, Christophe; Romanet, Jean-Paul; Renard, Jean-Paul

    2015-12-01

    To evaluate the visual field rate of progression of patients with treated ocular hypertension (OHT) and primary open-angle glaucoma (POAG) in clinical practice, using the mean deviation (MD) and the visual field index (VFI). Non-interventional cohort study. From a large multicentre database representative of the French population, 441 eyes of 228 patients with treated OHT or POAG followed up at least 6 years with Humphrey 24.2 Sita-Standard visual field examination at least twice a year were identified. From initial data, eyes were classified in five groups: 121 with OHT, 188 with early glaucoma (MD greater than -6 dB), 45 with moderate glaucoma (MD -6 to -12 dB), 41 with advanced glaucoma (MD -12 to -18 dB) and 46 with severe glaucoma (MD less than -18 dB). Rate of progression during the follow-up period was calculated using the trend analysis of the Guided Progression Analysis software. The mean duration of follow-up was 8.4 ± 2.7 years and the mean number of visual field, 18.4 ± 3.5. In eyes with OHT, rate of progression was -0.09 dB/year (-0.17%VFI/year). In eyes with POAG, rate of progression was -0.32 dB/year (-0.83%VFI/year) in eyes with early glaucoma, -0.52 dB/year (-1.81%VFI/year) in moderate glaucoma, -0.54 dB/year (-2.35%VFI/year) in advanced glaucoma and -0.45 dB/year (-1.97%VFI/year) in severe glaucoma. In eyes with POAG, a significant progression (p < 0.05) was detected in 159 of 320 eyes (49.7%) with trend analysis and 117 of 320 eyes (36.6%, likely progression) or 183 of 320 eyes (57.2%, possible and likely progression) with event analysis. Primary open-angle glaucoma is a progressive disease in the majority of patients despite cautioned treatment and follow-up. The rate of progression varies greatly among subjects. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Eye Movements of Patients with Tunnel Vision while Walking

    PubMed Central

    Vargas-Martín, Fernando; Peli, Eli

    2006-01-01

    Purpose To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head, while walking in real environments. This information should help to better define the visual field and clearance requirements for head-mounted mobility visual aids. Methods Eye positions relative to the head were recorded in five retinitis pigmentosa patients with less than 15° of visual field and three normally-sighted people, each walking in varied environments for more than 30 minutes. The eye position recorder was made portable by modifying a head-mounted ISCAN system. Custom data processing was implemented to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. Results PFL patients exhibited narrower horizontal eye position dispersions than normally-sighted subjects (9.4° vs. 14.2°, p < 0.0001) and PFL patients’ vertical dispersions were smaller when walking indoors than outdoors (8.2° vs. 10.3°, p = 0.048). Conclusions When walking, the PFL patients did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because saccadic amplitude is limited by a lack of peripheral stimulation. The results suggest that a field-of-view as wide as 40° may be needed for closed (immersive) head-mounted mobility aids, while a much narrower display, perhaps as narrow as 20°, might be sufficient with an open design. PMID:17122116

  4. Eye movements of patients with tunnel vision while walking.

    PubMed

    Vargas-Martín, Fernando; Peli, Eli

    2006-12-01

    To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P < 0.0001), and the vertical dispersions of patients with PFL were smaller when they were walking indoors than when walking outdoors (8.2 degrees vs. 10.3 degrees ; P = 0.048). When walking, the patients with PFL did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.

  5. Genetics of Primary Intraocular Tumors

    PubMed Central

    Nagarkatti-Gude, Nisha; Wang, Yujuan; Ali, Mohammad Javed; Honavar, Santosh G.; Jager, Martine J.; Chan, Chi-Chao

    2012-01-01

    Primary intraocular neoplasms are tumors that originate within the eye. The most common malignant primary intraocular tumor in adults is uveal melanoma and the second is primary intraocular lymphoma or vitreoretinal (intraocular) lymphoma. The most common malignant intraocular tumor in children is retinoblastoma. Genetics plays a vital role in the diagnosis and detection of ocular tumors. In uveal melanoma, monosomy 3 is the most common genetic alteration and somatic mutations of BAP1, a tumor suppressor gene, have been reported in nearly 50% of primary uveal melanomas. The retinoblastoma gene RB1 is the prototype tumor suppressor gene—mutations in RB1 alleles lead to inactivated RB protein and the development of retinoblastoma. Immunoglobulin heavy chain (IgH) or T-cell receptor (TCR) gene rearrangement is observed in B-cell or T-cell primary vitreoretinal lymphoma, respectively. Other factors related to the genetics of these three common malignancies in the eye are discussed and reviewed. PMID:22834783

  6. Impact of eye bank lamellar tissue cutting for endothelial keratoplasty on bacterial and fungal corneoscleral donor rim cultures after corneal transplantation.

    PubMed

    Rauen, Matthew P; Goins, Kenneth M; Sutphin, John E; Kitzmann, Anna S; Schmidt, Gregory A; Wagoner, Michael D

    2012-04-01

    To determine if the lamellar cut of donor tissue for endothelial keratoplasty (EK) by an eye bank facility is associated with a change in the prevalence of positive bacterial or fungal donor rim cultures after corneal transplantation. A retrospective review was conducted of bacterial and fungal cultures of donor rims used for corneal transplantation at a tertiary eye care center from January 1, 2003, to December 31, 2008, with tissue provided by a single eye bank. The cases were divided into 2 groups. Group 1 ("no-cut") included keratoplasty procedures in which a lamellar cut was not performed. Group 2 ("precut") included EK procedures in which a 4-hour period of prewarming of tissue followed by a lamellar cut was performed in the eye bank before tissue delivery to the operating surgeon. There were 351 donor rim cultures in group 1 and 278 in group 2. Bacterial cultures were positive in 30 donor rims (8.5%) in group 1 and 13 (4.7%) in group 2 (P = 0.058). Positive bacterial cultures were not associated with any postoperative infections. Fungal cultures were positive in 8 donor rims (2.3%) in group 1 and 7 (2.5%) in group 2 (P = 1.0). Positive fungal cultures were associated with 2 cases (13.3%) of postoperative fungal infections. Corneal donor tissue can be precut for EK by trained eye bank personnel without an increased risk of bacterial or fungal contamination.

  7. Quantitative Measurement of Eyestrain on 3D Stereoscopic Display Considering the Eye Foveation Model and Edge Information

    PubMed Central

    Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung

    2014-01-01

    We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors. PMID:24834910

  8. The origin of lunar mascon basins.

    PubMed

    Melosh, H J; Freed, Andrew M; Johnson, Brandon C; Blair, David M; Andrews-Hanna, Jeffrey C; Neumann, Gregory A; Phillips, Roger J; Smith, David E; Solomon, Sean C; Wieczorek, Mark A; Zuber, Maria T

    2013-06-28

    High-resolution gravity data from the Gravity Recovery and Interior Laboratory spacecraft have clarified the origin of lunar mass concentrations (mascons). Free-air gravity anomalies over lunar impact basins display bull's-eye patterns consisting of a central positive (mascon) anomaly, a surrounding negative collar, and a positive outer annulus. We show that this pattern results from impact basin excavation and collapse followed by isostatic adjustment and cooling and contraction of a voluminous melt pool. We used a hydrocode to simulate the impact and a self-consistent finite-element model to simulate the subsequent viscoelastic relaxation and cooling. The primary parameters controlling the modeled gravity signatures of mascon basins are the impactor energy, the lunar thermal gradient at the time of impact, the crustal thickness, and the extent of volcanic fill.

  9. Eye contact as an antecedent to compliant behavior

    PubMed Central

    Hamlet, Carolynn C.; Axelrod, Saul; Kuerschner, Steven

    1984-01-01

    Many experimenters and practitioners regard eye contact between instructor and learner as a facilitator, if not a prerequisite, to the effective instruction of sighted people. Without scientifically supporting the practice of demanding eye contact, experimenters, nonetheless, advocate its use and offer a variety of procedures to promote its acquisition. To justify the widespread use of demanded eye contact and to explain its role functionally, one experiment and data from six replications with nine subjects are presented. The primary experiment provides an empirical base for the training of eye contact prior to instruction. In a multiple-baseline design across two students demanded eye contact resulted in levels of compliance that were double and triple those of baseline. A tentative functional analysis of demanded eye contact is presented, followed by a discussion of the relationship of eye contact to attending. PMID:16795682

  10. Influence of eye micromotions on spatially resolved refractometry

    NASA Astrophysics Data System (ADS)

    Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Osipova, Irina Y.

    2001-01-01

    The influence eye micromotions on the accuracy of estimation of Zernike coefficients form eye transverse aberration measurements was investigated. By computer modeling, the following found eye aberrations have been examined: defocusing, primary astigmatism, spherical aberration of the 3rd and the 5th orders, as well as their combinations. It was determined that the standard deviation of estimated Zernike coefficients is proportional to the standard deviation of angular eye movements. Eye micromotions cause the estimation errors of Zernike coefficients of present aberrations and produce the appearance of Zernike coefficients of aberrations, absent in the eye. When solely defocusing is present, the biggest errors, cased by eye micromotions, are obtained for aberrations like coma and astigmatism. In comparison with other aberrations, spherical aberration of the 3rd and the 5th orders evokes the greatest increase of the standard deviation of other Zernike coefficients.

  11. The perception of heading during eye movements

    NASA Technical Reports Server (NTRS)

    Royden, Constance S.; Banks, Martin S.; Crowell, James A.

    1992-01-01

    Warren and Hannon (1988, 1990), while studying the perception of heading during eye movements, concluded that people do not require extraretinal information to judge heading with eye/head movements present. Here, heading judgments are examined at higher, more typical eye movement velocities than the extremely slow tracking eye movements used by Warren and Hannon. It is found that people require extraretinal information about eye position to perceive heading accurately under many viewing conditions.

  12. Extraocular muscle proprioception and eye position.

    PubMed

    Pettorossi, V E; Ferraresi, A; Draicchio, F; Errico, P; Santarelli, R; Manni, E

    1995-03-01

    In the lamb, acute unilateral section of the ophthalmic branch induced in the ipsilateral eye occasional oscillations of the resting position and misalignment of the horizontal vestibulo-ocular reflex (HVOR) with respect to the stimulus. Additional electrolytic lesion of the cells innervating the proprioceptors of the medial rectus muscle, or of the lateral rectus muscle in the contralateral semilunar ganglion, provoked a 4 degrees-7 degrees consensual eye deviation towards and away from the lesioned side, respectively. The optokinetic beating field was similarly deviated. Under these experimental conditions, HVOR showed enhanced gain and marked misalignment in both eyes. Therefore, the selective suppression of muscular proprioceptive input deviated both eyes towards the direction opposite to the muscle whose gangliar proprioceptive representation has been destroyed.

  13. FogEye UV Sensor System Performance Characteristics

    DOT National Transportation Integrated Search

    2004-03-01

    The primary objective of the FogEye Evaluation Program is to determine whether coupled ultra-violet sources and detectors may provide enhancements to safety on the airport surface. The results of this effort will be used to complete the evaluation of...

  14. Hyperthyroid vs hypothyroid eye disease: the same severity and activity

    PubMed Central

    Kashkouli, M B; Pakdel, F; Kiavash, V; Heidari, I; Heirati, A; Jam, S

    2011-01-01

    Purpose To compare demographics, severity, and activity of thyroid eye disease (TED) in patients with hyperthyroidism (Hr-TED) vs primary hypothyroidism (Ho-TED). Patients and Methods In a cross-sectional study, demographics, complete eye examination, severity score (NOSPECS, total hundred eye score), clinical activity score, and Rundle grading were recorded for patients with TED and different thyroid disorders referred from an endocrinology clinic from 2003 to 2006. Results TED was clinically found in 303 patients (303/851, 35.6%). The majority of them (280/303, 92.4%) had Graves' hyperthyroidism and 23 (23/303, 7.5%) had primary hypothyroidism. Mean age, gender, mean severity score, mean activity score, Rundle grade, unilateral presentation of TED, smoking habit, mean duration of eye disease, and mean interval time of thyroid to TED were not significantly different between the two groups (0.06

  15. A 6-year-old girl with restricted upward gaze of her right eye.

    PubMed

    Tuli, Sanjeev; Tuli, Sonal

    2012-08-01

    Brown syndrome is an incomitant strabismus syndrome characterized by inability of the eye to elevate during adduction. • Primary Brown syndrome is thought to occur due to the inability of the superior oblique tendon to stretch.However, there are many secondary causes of this condition that must be ruled out. • Despite significant misalignment of the eyes during upgaze, patients with Brown syndrome usually do not have decreased vision or diplopia with primary gaze. • Unlike paralytic strabismus, forced duction tests demonstrate restriction and a Parks’ three-step test does not demonstrate a paralytic muscle. Spontaneous resolution is frequent, and surgical management typically is not indicated because of the high incidence of postoperative symptomatic superior oblique palsy.

  16. Effect of gravity on vertical eye position.

    PubMed

    Pierrot-Deseilligny, C

    2009-05-01

    There is growing evidence that gravity markedly influences vertical eye position and movements. A new model for the organization of brainstem upgaze pathways is presented in this review. The crossing ventral tegmental tract (CVTT) could be the efferent tract of an "antigravitational" pathway terminating at the elevator muscle motoneurons in the third nerve nuclei and comprising, upstream, the superior vestibular nucleus and y-group, the flocculus, and the otoliths. This pathway functions in parallel to the medial longitudinal fasciculus pathways, which control vertical eye movements made to compensate for all vertical head movements and may also comprise the "gravitational" vestibular pathways, involved in the central reflection of the gravity effect. The CVTT could provide the upgaze system with the supplement of tonic activity required to counteract the gravity effect expressed in the gravitational pathway, being permanently modulated according to the static positions of the head (i.e., the instantaneous gravity vector) between a maximal activity in the upright position and a minimal activity in horizontal positions. Different types of arguments support this new model. The permanent influence of gravity on vertical eye position is strongly suggested by the vertical slow phases and nystagmus observed after rapid changes in hypo- or hypergravity. The chin-beating nystagmus, existing in normal subjects with their head in the upside-down position, suggests that gravity is not compensated for in the downgaze system. Upbeat nystagmus due to brainstem lesions, most likely affecting the CVTT circuitry, is improved when the head is in the horizontal position, suggesting that this circuitry is involved in the counteraction of gravity between the upright and horizontal positions of the head. In downbeat nystagmus due to floccular damage, in which a permanent hyperexcitation of the CVTT could exist, a marked influence of static positions of the head is also observed. Finally, the strongest argument supporting a marked role of gravity in vertical eye position is that the eye movement alterations observed in the main, typical physiological and pathological conditions are precisely those that would be expected from a direct effect of gravity on the eyeballs, with, moreover, no single alternative interpretation existing so far that could account for all these different types of findings.

  17. Corneal haze following PRK with mitomycin C as a retreatment versus prophylactic use in the contralateral eye.

    PubMed

    Netto, Marcelo V; Chalita, Maria Regina; Krueger, Ronald R

    2007-01-01

    To report photorefractive keratectomy (PRK) treated with mitomycin C (MMC) for previous corneal haze in one eye and PRK with MMC to prevent corneal haze formation in the fellow eye. A 40-year-old woman underwent PRK with MMC to treat previous corneal haze (secondary to previous PRK without MMC) for residual refractive error of +0.50 +0.25 x 165 in the left eye and PRK with MMC to prevent corneal haze in the right eye. Postoperative slit-lamp examination revealed no haze in the right eye, but continued mild haze in the left eye. Treatment with PRK and MMC for previous corneal haze is not as effective as primary PRK with MMC in preventing postoperative corneal haze formation.

  18. Spatial scale and distribution of neurovascular signals underlying decoding of orientation and eye of origin from fMRI data

    PubMed Central

    Harrison, Charlotte; Jackson, Jade; Oh, Seung-Mock; Zeringyte, Vaida

    2016-01-01

    Multivariate pattern analysis of functional magnetic resonance imaging (fMRI) data is widely used, yet the spatial scales and origin of neurovascular signals underlying such analyses remain unclear. We compared decoding performance for stimulus orientation and eye of origin from fMRI measurements in human visual cortex with predictions based on the columnar organization of each feature and estimated the spatial scales of patterns driving decoding. Both orientation and eye of origin could be decoded significantly above chance in early visual areas (V1–V3). Contrary to predictions based on a columnar origin of response biases, decoding performance for eye of origin in V2 and V3 was not significantly lower than that in V1, nor did decoding performance for orientation and eye of origin differ significantly. Instead, response biases for both features showed large-scale organization, evident as a radial bias for orientation, and a nasotemporal bias for eye preference. To determine whether these patterns could drive classification, we quantified the effect on classification performance of binning voxels according to visual field position. Consistent with large-scale biases driving classification, binning by polar angle yielded significantly better decoding performance for orientation than random binning in V1–V3. Similarly, binning by hemifield significantly improved decoding performance for eye of origin. Patterns of orientation and eye preference bias in V2 and V3 showed a substantial degree of spatial correlation with the corresponding patterns in V1, suggesting that response biases in these areas originate in V1. Together, these findings indicate that multivariate classification results need not reflect the underlying columnar organization of neuronal response selectivities in early visual areas. NEW & NOTEWORTHY Large-scale response biases can account for decoding of orientation and eye of origin in human early visual areas V1–V3. For eye of origin this pattern is a nasotemporal bias; for orientation it is a radial bias. Differences in decoding performance across areas and stimulus features are not well predicted by differences in columnar-scale organization of each feature. Large-scale biases in extrastriate areas are spatially correlated with those in V1, suggesting biases originate in primary visual cortex. PMID:27903637

  19. Management of Duane retraction syndrome with prismatic glasses

    PubMed Central

    Aygit, Ebru Demet; Kocamaz, Murat; Inal, Asli; Fazil, Korhan; Ocak, Osman Bulut; Akar, Serpil; Gokyigit, Birsen

    2017-01-01

    Purpose To report the results of using prismatic glasses for Duane retraction syndrome (DRS). Methods Data were obtained from the records of patients who were evaluated during the year 2000 in the Strabismus Unit of the Beyoglu Eye Training and Research Hospital. The average follow-up was 12.2±17.7 months. In all cases, 2 main variables were evaluated: horizontal deviation in the primary position and face turn. Prismatic glasses were provided to patients according to the degree of shift in the primary position. Results The mean age of patients was 11.2 years. An analysis was performed on the data collected from 12 cases; 7 patients were females (58.3%) and 5 were males (41.7%), with 11 (91.7%) cases being of type I DRS. All 12 patients had abnormal head posture (face turn) and an angle of mean deviation equaling 10 PD (prism dioptri). Conclusion Treatment was individualized on a case-by-case basis. Prismatic glasses are useful for eliminating abnormal head posture and ocular misalignment in selected cases. PMID:28442887

  20. Are Eyes a Mirror of the Soul? What Eye Wrinkles Reveal about a Horse’s Emotional State

    PubMed Central

    Hintze, Sara; Smith, Samantha; Patt, Antonia; Bachmann, Iris; Würbel, Hanno

    2016-01-01

    Finding valid indicators of emotional states is one of the biggest challenges in animal welfare science. Here, we investigated in horses whether variation in the expression of eye wrinkles caused by contraction of the inner eyebrow raiser reflects emotional valence. By confronting horses with positive and negative conditions, we aimed to induce positive and negative emotional states, hypothesising that positive emotions would reduce whereas negative emotions would increase eye wrinkle expression. Sixteen horses were individually exposed in a balanced order to two positive (grooming, food anticipation) and two negative conditions (food competition, waving a plastic bag). Each condition lasted for 60 seconds and was preceded by a 60 second control phase. Throughout both phases, pictures of the eyes were taken, and for each horse four pictures per condition and phase were randomly selected. Pictures were scored in random order and by two experimenters blind to condition and phase for six outcome measures: qualitative impression, eyelid shape, markedness of the wrinkles, presence of eye white, number of wrinkles, and the angle between the line through the eyeball and the highest wrinkle. The angle decreased during grooming and increased during food competition compared to control phases, whereas the two phases did not differ during food anticipation and the plastic bag condition. No effects on the other outcome measures were detected. Taken together, we have defined a set of measures to assess eye wrinkle expression reliably, of which one measure was affected by the conditions the horses were exposed to. Variation in eye wrinkle expression might provide valuable information on horse welfare but further validation of specific measures across different conditions is needed. PMID:27732647

  1. Effect of direct eye contact in women with PTSD related to interpersonal trauma: Psychophysiological interaction analysis of connectivity of an innate alarm system.

    PubMed

    Steuwe, Carolin; Daniels, Judith K; Frewen, Paul A; Densmore, Maria; Theberge, Jean; Lanius, Ruth A

    2015-05-30

    In healthy individuals, direct eye contact is thought to modulate a cortical route eliciting social cognitive processes via activation of a fast subcortical pathway. This study aimed to examine functional brain connectivity during direct eye contact in women with posttraumatic stress disorder (PTSD) related to childhood abuse as compared with healthy controls. We conducted psychophysiological interaction (PPI) analyses in Statistical Parametric Mapping-8 (SPM8) using the superior colliculus (SC) and locus coeruleus (LC) as seed regions while 16 healthy subjects and 16 patients with a primary diagnosis of PTSD related to childhood maltreatment viewed a functional magnetic resonance imaging (fMRI) paradigm involving direct (D) versus averted (A) gaze (happy, sad, neutral). The PTSD group showed a significantly enhanced connectivity between the SC and the anterior cingulate, and between the LC and the thalamus, caudate, putamen, insula, cingulate gyrus, and amygdala, as compared with healthy individuals. Symptom severity scores on the Clinician-Administered PTSD Scale (CAPS) showed significant positive correlations with superior colliculus connectivity with the perigenual and posterior cingulate, insula, and sublenticular extended amygdala. Functional connectivity data suggest increased recruitment of brain regions involved in emotion processing during direct gaze in PTSD in association with the fast subcortical pathway. The interpretation of eye contact as a signal of threat may require more emotion regulatory capacities in patients with PTSD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. The protective efficacy and safety of bandage contact lenses in children aged 5 to 11 after frontalis muscle flap suspension for congenital blepharoptosis: A single-center randomized controlled trial.

    PubMed

    Chen, Lin; Pi, Lianhong; Ke, Ning; Chen, Xinke; Liu, Qing

    2017-09-01

    Postoperative complications, lagophthalmos and exposure keratopathy sometimes occur after surgery for congenital blepharoptosis. Bandage contact lenses (BCL) can help prevent some ocular surface disorders. The study aims to evaluate the efficacy and safety of BCL for protection of the ocular surface in children aged 5 to 11 years after frontalis muscle flap suspension for congenital blepharoptosis. We conducted a prospective randomized clinical study of 30 eyes of 30 patients with congenital blepharoptosis consecutively enrolled at the Ophthalmology Ward of the Children's Hospital of Chongqing Medical University, China from September 1, 2016, to February 30, 2017. After frontalis muscle flap suspension surgery, patients were randomly assigned to undergo BCL application (BCL group, 15 eyes) or no BCL application (control group, 15 eyes). All patients were treated with bramycin 0.3% and polyvinyl alcohol drops after surgery. The primary outcomes were dry eye assessed by tear film break time (TFBUT), fluoresce in corneal staining (FCS) on slit-lamp on days 1, 3, and 15 postoperatively, and lower tear meniscus height (LTMH) on optical coherence tomography on days 1 and 15 postoperatively. Secondary outcomes were pairwise correlation of TFBUT, FCS and LTMH. In the BCL group, abnormal TFBUT and FCS were only found in 2 patients (13.33%) on postoperative day 15. In the control group, the incidence of dry eye assessed by TFBUT was 67.00% (10/15 eyes) on day 1, 73.33% (11/15 eyes) on day 3, and 53.33% (8/15 eyes) on day 15 (P < .001). LTMH were significantly higher in the BCL group than the control group postoperatively (P < .001). Significant positive correlations were found between LTMH and TFBUT pre-operation and on days 1 and 15 post-operation. For LTMH and FCSS (R = -0.815, P < .001), and TFBUT and FCS (R = -0.837, P < .001), the Pearson coefficient was negative on postoperative day 1, but not correlated on day 15. Silicone hydrogel BCL were safe and efficacious for protective use in children after frontalis muscle flap suspension for congenital blepharoptosis.

  3. FogEye UV Sensor System Evaluation : Phase II Report

    DOT National Transportation Integrated Search

    2003-12-01

    The primary objective of the FogEye Evaluation Program is to determine whether coupled ultra-violet sources and detectors may provide enhancements to safety on the airport surface. The results of this effort will be used to complete the evaluation of...

  4. Evaluation of retinal ganglion cell function after intraocular pressure reduction measured by pattern electroretinogram in patients with primary open-angle glaucoma.

    PubMed

    Karaśkiewicz, Joanna; Penkala, Krzysztof; Mularczyk, Maciej; Lubiński, Wojciech

    2017-04-01

    To evaluate retinal ganglion cell (RGC) function after intraocular pressure (IOP) reduction measured by pattern electroretinogram (PERG) in patients with newly diagnosed, non-treated preperimetric and early stages of primary open-angle glaucoma (POAG). Twenty-four eyes from 24 patients with POAG: 11 eyes with preperimetric glaucoma and 13 eyes with early glaucoma received Ganfort ® (bimatoprost + timolol) once a day for a period of 1 month. Before and after the treatment, following measurements were analyzed: IOP, mean ocular perfusion pressure (MOPP), peak time of P50 and amplitude of P50 and N95 waves in PERG (ISCEV standard 2012). Correlations between PERG P50 and N95 waves, IOP and MOPP were calculated. After therapy, IOP significantly decreased in all eyes, on average 31%. Significant increase in MOPP in all eyes on average 14% was detected. PERG amplitude of P50 and N95 waves increased in 75 and 79% eyes, respectively, on average P50 by 28% and N95 by 38%. There were no significant interactions between the change of PERG parameters in time and stage of glaucoma. Significant IOP-lowering therapy can improve RGC function measured by PERG, in patients with preperimetric and early stages of POAG.

  5. Primary Sjögren's syndrome with diffuse cystic lung changes developed systemic lupus erythematosus: a case report and literature review.

    PubMed

    Liu, Xiao; Li, Hao; Yin, Yunhong; Ma, Dedong; Qu, Yiqing

    2017-05-23

    Sjögren's syndrome (SS) is a chronic inflammatory autoimmune disease that can occur as a unique existence (primary Sjögren's syndrome) or merge with other systemic diseases like systemic lupus erythematosus (SLE), rheumatoid arthritis or systemic sclerosis (secondary Sjögren's syndrome). Data on the two diseases occurrence order are inadequate. Primary Sjögren's syndrome (pSS) may relatively uncommonly lead to diffuse cystic lung changes. We represent a female who was diagnosed pSS with diffuse cystic lung alterations developed SLE two years later. SS was diagnosed on account of the existence of dryness of eye and mouth, Schirmer's test, biopsy of the minor salivary glands of her lip, positive anti-SSA and anti-SSB antibody in the serum. Chest computed tomography image showed bilateral diffuse cystic changes with a wide variation in cyst size and distribution. SLE was finally diagnosed based on bilateral lower limb skin rash, gonarthritis and omarthritis, low level of complement, antinuclear antibody 1:640 and positive antibodies to double-stranded DNA. Improvement was achieved with therapy of corticosteroids, hydroxychloroquine and antibiotics. This report provides us clinical, diagnosis and treatment perception of SS-onset SLE as patient presenting diffuse cystic lung changes.

  6. Looking into the water with oblique head tilting: revision of the aerial binocular imaging of underwater objects.

    PubMed

    Horváth, Gábor; Buchta, Krisztián; Varjú, Dezsö

    2003-06-01

    It is a well-known phenomenon that when we look into the water with two aerial eyes, both the apparent position and the apparent shape of underwater objects are different from the real ones because of refraction at the water surface. Earlier studies of the refraction-distorted structure of the underwater binocular visual field of aerial observers were restricted to either vertically or horizontally oriented eyes. We investigate a generalized version of this problem: We calculate the position of the binocular image point of an underwater object point viewed by two arbitrarily positioned aerial eyes, including oblique orientations of the eyes relative to the flat water surface. Assuming that binocular image fusion is performed by appropriate vergent eye movements to bring the object's image onto the foveas, the structure of the underwater binocular visual field is computed and visualized in different ways as a function of the relative positions of the eyes. We show that a revision of certain earlier treatments of the aerial imaging of underwater objects is necessary. We analyze and correct some widespread erroneous or incomplete representations of this classical geometric optical problem that occur in different textbooks. Improving the theory of aerial binocular imaging of underwater objects, we demonstrate that the structure of the underwater binocular visual field of aerial observers distorted by refraction is more complex than has been thought previously.

  7. Reliability of fluorescein dye disappearance test in assessment of adults with nasolacrimal duct obstruction.

    PubMed

    Kashkouli, Mohsen Bahmani; Mirzajani, Hoora; Jamshidian-Tehrani, Mansooreh; Pakdel, Farzad; Nojomi, Marzieh; Aghaei, Gholam-Hossein

    2013-01-01

    To evaluate the role of fluorescein dye disappearance test (FDDT) in assessment of adults with primary acquired nasolacrimal duct obstruction (PANDO) and its correlation with age and severity of epiphora. In a prospective, cross-sectional comparative study, FDDT at 2 (2-FDDT), 5 (5-FDDT), and 10 (10-FDDT) minutes were performed in 58 eyes of 58 patients with PANDO (case) and 58 eyes of 58 subjects without epiphora (control) between 2008 and 2010. Exclusion criteria were any disease, trauma, or medications that might have an effect on tear drainage system. Patients with functional or incomplete obstruction and upper lacrimal drainage system obstruction were excluded in the case group. FDDT and severity of epiphora were graded. Case and control groups were matched. 2-FDDT showed a sensitivity of 82.8%, specificity of 91.4%, positive predictive value of 90.6%, and negative predictive value of 84.1%. Sensitivity and negative predictive value decreased to 71.1% and 78.6% in 5-FDDT. 5-FDDT specificity and positive predictive value, however, increased to 94.8% and 93.5%, respectively. There was no statistically significant correlation between severity of epiphora and age with FDDT. FDDT is a simple, reliable, and highly specific test in assessment of adults with PANDO.

  8. Keratoconus and Normal-Tension Glaucoma: A Study of the Possible Association with Abnormal Biomechanical Properties as Measured by Corneal Hysteresis (An AOS Thesis)

    PubMed Central

    Cohen, Elisabeth J.

    2009-01-01

    Purpose: To test the hypothesis that keratoconus and pellucid patients who have glaucoma or are suspected of having glaucoma have lower corneal hysteresis (CH) and/or corneal resistance factor (CRF) measurements compared to controls. Methods: A prospective study at a tertiary eye center of keratoconus and pellucid patients with glaucoma or suspected of having glaucoma, and age-matched keratoconus and pellucid controls, was performed. After informed consent was obtained, corneal topography, ocular response analyzer measurements, pachymetry, intraocular pressure, A-scan measurements, Humphrey visual fields (VFs), and disc photos were done. Analyses compared cases to controls on primary (CH and CRF) and secondary variables. Disc photos and VFs were rated in a masked fashion. Results: The mean CH (8.2, SD=1.6, vs 8.3, SD=1.5) and CRF (7.3, SD=2.0, vs 6.9, SD=2.1) were low and did not differ significantly between 20 study patients (29 eyes) and 40 control patients (61 eyes), respectively. CH had a negative, significant correlation with maximum corneal curvature by topography (P < .002) and positive, significant correlation with central corneal thickness (P < .003). The mean cup-disc ratio was larger among cases than controls (0.54, SD=0.20, vs 0.38, SD=0.20; P = .003). VFs were suggestive of glaucoma more often among the study eyes than controls (11 of 29, 37.9%, vs 8 of 60, 13.3%; P =.019). Conclusions: CH was low in study and control patients and was correlated with severity of keratoconus/pellucid, but not with glaucoma/suspected glaucoma or control status. Evidence of glaucoma was more common in study eyes than controls, but was present in both. PMID:20126503

  9. The application of autologous serum eye drops in severe dry eye patients; subjective and objective parameters before and after treatment.

    PubMed

    Jirsova, Katerina; Brejchova, Kristyna; Krabcova, Ivana; Filipec, Martin; Al Fakih, Aref; Palos, Michalis; Vesela, Viera

    2014-01-01

    To assess the impact of autologous serum (AS) eye drops on the ocular surface of patients with bilateral severe dry eye and to draw a comparison between the clinical and laboratory examinations and the degree of subjective symptoms before and after serum treatment. A three-month prospective study was conducted on 17 patients with severe dry eye. AS eye drops were applied a maximum of 12 times a day together with regular therapy. Dry eye status was evaluated by clinical examination (visual acuity, Schirmer test, tear film breakup time, vital staining, tear film debris and meniscus), conjunctival impression cytology (epithelial and goblet cell density, snake-like chromatin, HLA-DR-positive and apoptotic cells) and subjectively by the patients. The application of AS eye drops led to a significant improvement in the Schirmer test (p < 0.01) and tear film debris (p < 0.05). The densities of goblet (p < 0.0001) and epithelial cells (p < 0.05) were significantly increased, indicating a decrease of squamous metaplasia after AS treatment. A significant decrease (p < 0.05) was found in the number of apoptotic, HLA-DR-positive and snake-like chromatin cells on the ocular surface. A significant improvement was found in all evaluated subjective symptoms. Altogether, the clinical results were improved in 77%, the laboratory results in 75% and the subjective feelings in 63% of the eyes. We found that three-month AS treatment led especially to the improvement of ocular surface dryness and damage of the epithelium. The improvement of dry eye after AS treatment correlated well with the clinical, laboratory and subjective findings. From the patients' subjective point of view, the positive effect of AS decreased with time, but still persisted up to three months after the end of therapy.

  10. Outcomes and Complications of Ahmed Tube Implantation in Asian Eyes.

    PubMed

    Choo, Jessica Qian Hui; Chen, Ziyou David; Koh, Victor; Liang, Shen; Aquino, Cecilia Maria; Sng, Chelvin; Chew, Paul

    2018-06-18

    There is a lack of long-term Asian studies on the efficacy and safety of Ahmed glaucoma valve (AGV) implantation. This study seeks to determine the outcomes and complications of AGV implantation in Asians. Retrospective review of AGV surgeries performed at a single centre in Singapore was conducted. 76 patients with primary and secondary glaucoma who underwent their first AGV surgery from 1st January 2010 to 31st December 2012 were considered for our study. Primary outcomes evaluated were: failure, intra-ocular pressure, best-corrected visual acuity (BCVA), number of IOP-lowering medications and complications. Failure was defined by: IOP >21▒mm Hg on two consecutive visits after 3 months, IOP ≤5▒mm Hg on two consecutive visits after 3 months, reoperation for glaucoma, removal of implant or loss of light perception vision. Mean follow-up duration was 33.2±6.9 months. There was significant reduction in IOP (mean reduction 25.9%, P<0.001) and number of IOP-lowering medications (mean reduction 77.8%, P<0.001) at 3 years. Absolute failure rate was 23.9% at 3 years with no difference between eyes with or without previous trabeculectomy and between eyes with primary or secondary glaucoma. Occurrence of post-operative hyphema was a significant risk factor for failure. Commonest post-operative complications were hyphema and tube exposure. At 3 years after AGV surgery in Asian eyes, less than one-quarter of the eyes fulfilled the criteria for surgical failure.

  11. Methods and Devices for Space Optical Communications Using Laser Beams

    NASA Technical Reports Server (NTRS)

    Goorjian, Peter M. (Inventor)

    2018-01-01

    Light is used to communicate between objects separated by a large distance. Light beams are received in a telescopic lens assembly positioned in front of a cat's-eye lens. The light can thereby be received at various angles to be output by the cat's-eye lens to a focal plane of the cat's-eye lens, the position of the light beams upon the focal plane corresponding to the angle of the beam received. Lasers and photodetectors are distributed along this focal plane. A processor receives signals from the photodetectors, and selectively signal lasers positioned proximate the photodetectors detecting light, in order to transmit light encoding data through the cat's-eye lens and also through a telescopic lens back in the direction of the received light beams, which direction corresponds to a location upon the focal plane of the transmitting lasers.

  12. Promoting organ donation through an entertainment-education TV program in Korea: Open Your Eyes.

    PubMed

    Byoung Kwan Lee; Hyun Soon Park; Choi, Myung-Il; Cheon Soo Kim

    2010-01-01

    The purpose of this study is to investigate the effects of the characteristics of the program, Open Your Eyes, an entertainment-education TV program in Korea, on parasocial interaction and behavioral intention for organ donation. The results indicated that affective evaluation positively affected parasocial interaction with the program but cognitive evaluation negatively affected involvement with beneficiaries in the program. Also, it was found that cognitive evaluation of Open Your Eyes had a significant positive effect on behavioral intention. In addition, a significant positive effect of program engagement on the behavioral intention was found. Thus, the results indicate that individuals who feel program engagement of Open Your Eyes will be more likely to proceed with organ donation. However, no direct effect of involvement with the beneficiary and program hosts was found.

  13. Retinal Layers Measurements following Silicone Oil Tamponade for Retinal Detachment Surgery.

    PubMed

    Jurišić, Darija; Geber, Mia Zorić; Ćavar, Ivan; Utrobičić, Dobrila Karlica

    2017-12-19

    This study aimed to investigate the influence of silicone oil on the retinal nerve fiber layer (RNFL) thickness in patients with primary rhegmatogenous retinal detachment who underwent vitreoretinal surgery. The study included 47 patients (eyes), who underwent a pars plana vitrectomy with the silicone oil tamponade. The control group included unoperated eye of all participants. Spectral-domain optical coherence tomography (SD-OCT) was used for the measurements of peripapilar and macular RNFL thickness. The average peripapillary RNFL thickness was significantly higher in the silicone oil filled eyes during endotamponade and after its removal. The eyes with elevated IOP had less thickening of the RNFL in comparison to the eyes with normal IOP. Central macular thickness and macular volume were decreased in the silicone oil filled eyes in comparison to the control eyes. In conclusion, silicone oil caused peripapilar RNFL thickening in the vitrectomized eyes during endotamponade and after silicone oil removal.

  14. Individual Differences in Affect.

    ERIC Educational Resources Information Center

    Haviland, Jeannette

    This paper argues that infants' affect patterns are innate and are meaningful indicators of individual differences in internal state. Videotapes of seven infants' faces were coded using an ethogram; the movement of the eyebrow, eye direction, eye openness, mouth shape, mouth position, lip position, and tongue protrusion were assessed…

  15. Accommodation and the Visual Regulation of Refractive State in Marmosets

    PubMed Central

    Troilo, David; Totonelly, Kristen; Harb, Elise

    2009-01-01

    Purpose To determine the effects of imposed anisometropic retinal defocus on accommodation, ocular growth, and refractive state changes in marmosets. Methods Marmosets were raised with extended-wear soft contact lenses for an average duration of 10 wks beginning at an average age of 76 d. Experimental animals wore either a positive or negative contact lens over one eye and a plano lens or no lens over the other. Another group wore binocular lenses of equal magnitude but opposite sign. Untreated marmosets served as controls and three wore plano lenses monocularly. Cycloplegic refractive state, corneal curvature, and vitreous chamber depth were measured before, during, and after the period of lens wear. To investigate the accommodative response, the effective refractive state was measured through each anisometropic condition at varying accommodative stimuli positions using an infrared refractometer. Results Eye growth and refractive state are significantly correlated with the sign and power of the contact lens worn. The eyes of marmosets reared with monocular negative power lenses had longer vitreous chambers and were myopic relative to contralateral control eyes (p<0.01). Monocular positive power lenses produced a significant reduction in vitreous chamber depth and hyperopia relative to the contralateral control eyes (p<0.05). In marmosets reared binocularly with lenses of opposite sign, we found larger interocular differences in vitreous chamber depths and refractive state (p<0.001). Accommodation influences the defocus experienced through the lenses, however, the mean effective refractive state was still hyperopia in the negative-lens-treated eyes and myopia in the positive-lens-treated eyes. Conclusions Imposed anisometropia effectively alters marmoset eye growth and refractive state to compensate for the imposed defocus. The response to imposed hyperopia is larger and faster than the response to imposed myopia. The pattern of accommodation under imposed anisometropia produces effective refractive states that are consistent with the changes in eye growth and refractive state observed. PMID:19104464

  16. Opposite Effects of Glucagon and Insulin on Compensation for Spectacle Lenses in Chicks

    PubMed Central

    Zhu, Xiaoying; Wallman, Josh

    2009-01-01

    Purpose Chick eyes compensate for defocus imposed by positive or negative spectacle lenses. Glucagon may signal the sign of defocus. Do insulin (or IGF-1) and glucagon act oppositely in controlling eye growth, as they do in metabolic pathways and in control of retinal neurogenesis? Methods Chicks, wearing either lenses or diffusers or neither over both eyes, were injected with glucagon, a glucagon antagonist, insulin, or IGF-1 in one eye (saline in other eye). Alternatively, chicks without lenses received insulin plus glucagon in one eye, and either glucagon or insulin in the fellow eye. Ocular dimensions, refractive errors and glycosaminoglycan synthesis were measured over 2-4 days. Results Glucagon attenuated the myopic response to negative lenses or diffusers by slowing ocular elongation and thickening the choroid; in contrast, with positive lenses, it increased ocular elongation to normal levels and reduced choroidal thickening, as did a glucagon antagonist. Insulin prevented the hyperopic response to positive lenses by speeding ocular elongation and thinning the choroid. In eyes without lenses, both insulin and IGF-1 speeded, and glucagon slowed, ocular elongation, but either glucagon or insulin increased the rate of thickening of the crystalline lens. When injected together, insulin blocked choroidal thickening by glucagon, at a dose that did not, by itself, thin the choroid. Conclusions Glucagon and insulin (or IGF-1) cause generally opposite modulations of eye-growth, with glucagon mostly increasing choroidal thickness and insulin mostly increasing ocular elongation. These effects are mutually inhibitory and depend on the visual input. PMID:18791176

  17. ELECTRICAL STUDIES ON THE COMPOUND EYE OF LIGIA OCCIDENTALIS DANA (CRUSTACEA: ISOPODA)

    PubMed Central

    Ruck, Philip; Jahn, Theodore L.

    1954-01-01

    The ERG of the compound eye in freshly collected Ligia occidentalis, in response to high intensity light flashes of ⅛ second or longer duration, begins with a negative on-effect quickly followed by an early positive deflection, rapidly returns to the baseline during illumination, and ends with a positive off-effect. As the stimulus intensity is decreased the early positivity progressively decreases and the rapid return to the baseline is replaced by a slowing decline of the negative on-effect. Responses were recorded with one active electrode subcorneally situated in the illuminated eye, the reference electrode in the dark eye. The dark-adapted eye shows a facilitation of the amplitude and rates of rise and fall of the on-effect to a brief, high intensity light stimulus. This facilitation may persist for more than 2 minutes. Following light adaptation under conditions in which the human eye loses sensitivity by a factor of almost 40,000 the Ligia eye loses sensitivity by a factor of only 3. The flicker fusion frequency of the ERG may be as high as 120/second with a corneal illumination of 15,000 foot-candles. Bleeding an otherwise intact animal very rapidly results in a decline of amplitude, change of wave form, and loss of facilitation in the ERG. When the eye is deganglionated without bleeding the animal the isolated retina responds in the same manner as the intact eye. Histological examination of the Ligia receptor layer showed that each ommatidium contains three different retinula cell types, each of which may be responsible for a different aspect of the ERG. PMID:13174786

  18. Ocular consequences of bottle rocket injuries in children and adolescents.

    PubMed

    Khan, Mehnaz; Reichstein, David; M Recchia, Franco

    2011-05-01

    To describe the spectrum of ocular injuries and associated visual morbidity in the pediatric and adolescent population caused by bottle rockets. Retrospective review of consecutive medical records of patients 18 years or younger seen during a recent 4-year period. Outcome measures were ocular injuries at time of visit, interventions required, visual acuity at most recent follow-up, and most recent anatomic findings. Eleven eyes from 10 patients (8 boys and 2 girls aged 5-17 years) were identified. Significant ocular injuries included corneal epithelial defect (7 eyes), hyphema (6 eyes), traumatic iritis (2 eyes), iridodialysis (4 eyes), cataract (4 eyes), retinal dialysis (1 eye), and vitreous hemorrhage (2 eyes). Eight eyes required primary intervention (lensectomy in 4 eyes, corneal debridement in 2 eyes, globe exploration in 1 eye, and retinal laser photocoagulation in 1 eye). Three patients required additional procedures. These secondary interventions included pars plana vitrectomy (1 eye), muscle surgery for sensory strabismus (1 eye), corneal debridement (1 eye), and intraocular lens placement (1 eye). Most recent visual acuity (10 eyes with follow-up) was 20/30 or better in 4 eyes and 20/200 or worse in 6 eyes (for 1 eye, the patient was unavailable for follow-up). Permanent visual impairment was typically due to traumatic maculopathy. Bottle rockets can cause significant ocular injury in children, often with permanent loss of vision.

  19. Tracking the eye non-invasively: simultaneous comparison of the scleral search coil and optical tracking techniques in the macaque monkey

    PubMed Central

    Kimmel, Daniel L.; Mammo, Dagem; Newsome, William T.

    2012-01-01

    From human perception to primate neurophysiology, monitoring eye position is critical to the study of vision, attention, oculomotor control, and behavior. Two principal techniques for the precise measurement of eye position—the long-standing sclera-embedded search coil and more recent optical tracking techniques—are in use in various laboratories, but no published study compares the performance of the two methods simultaneously in the same primates. Here we compare two popular systems—a sclera-embedded search coil from C-N-C Engineering and the EyeLink 1000 optical system from SR Research—by recording simultaneously from the same eye in the macaque monkey while the animal performed a simple oculomotor task. We found broad agreement between the two systems, particularly in positional accuracy during fixation, measurement of saccade amplitude, detection of fixational saccades, and sensitivity to subtle changes in eye position from trial to trial. Nonetheless, certain discrepancies persist, particularly elevated saccade peak velocities, post-saccadic ringing, influence of luminance change on reported position, and greater sample-to-sample variation in the optical system. Our study shows that optical performance now rivals that of the search coil, rendering optical systems appropriate for many if not most applications. This finding is consequential, especially for animal subjects, because the optical systems do not require invasive surgery for implantation and repair of search coils around the eye. Our data also allow laboratories using the optical system in human subjects to assess the strengths and limitations of the technique for their own applications. PMID:22912608

  20. Liquid Nitrogen Cryotherapy for Surface Eye Disease (An AOS Thesis)

    PubMed Central

    Fraunfelder, Frederick Web

    2008-01-01

    Purpose To evaluate the effects of new treatments with liquid nitrogen cryotherapy on some external eye conditions. Methods In this retrospective case study, 6 separate series from a single tertiary care referral center practice are described. Liquid nitrogen cryotherapy was used to treat conjunctival amyloidosis, primary pterygia, recurrent pterygia, advancing wavelike epitheliopathy (AWLE), superior limbic keratoconjunctivitis (SLK), and palpebral vernal keratoconjunctivitis (VKC). The main outcome measure was the resolution of the disease process after treatment. Results Four patients with primary localized conjunctival amyloidosis were treated with liquid nitrogen cryotherapy. Two of them had recurrence of the amyloidosis, which cleared with subsequent treatment. Eighteen patients with primary pterygia had excision and cryotherapy with 1 recurrence. Of 6 subjects who presented with recurrent pterygia, 4 had a second recurrence after excision and cryotherapy. In 5 patients with AWLE, the condition resolved within 2 weeks without recurrence or the need for subsequent cryotherapy. Four patients with SLK were treated with liquid nitrogen cryotherapy. Disease recurred in 2 patients and 3 of 7 eyes, although subsequent cryotherapy eradicated SLK in all cases. Two patients and 3 eyelids with palpebral VKC were treated with liquid nitrogen cryotherapy. VKC recurred in all cases. Conclusions Liquid nitrogen cryotherapy to the surface of the eye is effective in treating AWLE, and SLK. Excision followed by cryotherapy is successful in treating conjunctival amyloidosis and primary pterygia Liquid nitrogen cryotherapy is unsuccessful in the treatment of recurrent pterygia and VKC. PMID:19277243

  1. Temporal dynamics of ocular position dependence of the initial human vestibulo-ocular reflex.

    PubMed

    Crane, Benjamin T; Tian, Junru; Demer, Joseph L

    2006-04-01

    While an ideal vestibulo-ocular reflex (VOR) generates ocular rotations compensatory for head motion, during visually guided movements, Listing's Law (LL) constrains the eye to rotational axes lying in Listing's Plane (LP). The present study was conducted to explore the recent proposal that the VOR's rotational axis is not collinear with the head's, but rather follows a time-dependent strategy intermediate between LL and an ideal VOR. Binocular LPs were defined during visual fixation in eight normal humans. The VOR was evoked by a highly repeatable transient whole-body yaw rotation in darkness at a peak acceleration of 2800 deg/s2. Immediately before rotation, subjects regarded targets 15 or 500 cm distant located at eye level, 20 degrees up, or 20 degrees down. Eye and head responses were compared with LL predictions in the position and velocity domains. LP orientation varied both among subjects and between individual subject's eyes, and rotated temporally with convergence by 5 +/- 5 degrees (+/-SEM). In the position domain, the eye compensated for head displacement even when the head rotated out of LP. Even within the first 20 ms from onset of head rotation, the ocular velocity axis tilted relative to the head axis by 30% +/- 8% of vertical gaze position. Saccades increased this tilt. Regardless of vertical gaze position, the ocular rotation axis tilted backward 4 degrees farther in abduction than in adduction. There was also a binocular vertical eye velocity transient and lateral tilt of the ocular axis. These disconjugate, short-latency axis perturbations appear intrinsic to the VOR and may have neural or mechanical origins.

  2. Helmet Mounted Eye Tracking for Virtual Panoramic Displays. Volume 1: Review of Current Eye Movement Measurement Technology

    DTIC Science & Technology

    1989-08-01

    paths for integration with the off-aperture and dual-mirror VPD designs. PREFACE The goal of this work was to explore integration of an eye line-of- gaze ...Relationship in one plane between point-of- gaze on a flat scene and relative eye, detector, and scene positions...and eye line-of- gaze measurement. As a first step towards the design of an appropriate eye trac.<ing system for interface with the virtual cockpit

  3. Residencies at The Eye Institute of the Pennsylvania College of Optometry.

    ERIC Educational Resources Information Center

    Alexander, Arthur H.; Klopfer, Joann

    1983-01-01

    An optometric residency program at The Eye Institute of the Pennsylvania College of Optometry that focuses on clinical training in the areas of low vision rehabilitation, pediatric optometry, visual training, behavioral vision, primary care optometry and hospital based optometry is discussed. (MSW)

  4. The cost-effectiveness of Welcome to Medicare visual acuity screening and a possible alternative welcome to medicare eye evaluation among persons without diagnosed diabetes mellitus.

    PubMed

    Rein, David B; Wittenborn, John S; Zhang, Xinzhi; Hoerger, Thomas J; Zhang, Ping; Klein, Barbara Eden Kobrin; Lee, Kris E; Klein, Ronald; Saaddine, Jinan B

    2012-05-01

    To estimate the cost-effectiveness of visual acuity screening performed in primary care settings and of dilated eye evaluations performed by an eye care professional among new Medicare enrollees with no diagnosed eye disorders. Medicare currently reimburses visual acuity screening for new enrollees during their initial preventive primary care health check, but dilated eye evaluations may be a more cost-effective policy. Monte Carlo cost-effectiveness simulation model with a total of 50 000 simulated patients with demographic characteristics matched to persons 65 years of age in the US population. Compared with no screening policy, dilated eye evaluations increased quality-adjusted life-years(QALYs) by 0.008 (95% credible interval [CrI], 0.005-0.011) and increased costs by $94 (95% CrI, −$35 to$222). A visual acuity screening increased QALYs in less than 95% of the simulations (0.001 [95% CrI, −0.002 to 0.004) and increased total costs by $32 (95% CrI, −$97 to $159) per person. The incremental cost-effectiveness ratio of a visual acuity screening and an eye examination compared with no screening were $29 000 and$12 000 per QALY gained, respectively. At a willingness-to-pay value of $15 000 or more per QALY gained, a dilated eye evaluation was the policy option most likely to be cost-effective. The currently recommended visual acuity screening showed limited efficacy and cost-effectiveness compared with no screening. In contrast, anew policy of reimbursement for Welcome to Medicare dilated eye evaluations was highly cost-effective.

  5. The Cost-effectiveness of Welcome to Medicare Visual Acuity Screening and a Possible Alternative Welcome to Medicare Eye Evaluation Among Persons Without Diagnosed Diabetes Mellitus

    PubMed Central

    Rein, David B.; Wittenborn, John S.; Zhang, Xinzhi; Hoerger, Thomas J.; Zhang, Ping; Klein, Barbara Eden Kobrin; Lee, Kris E.; Klein, Ronald; Saaddine, Jinan B.

    2013-01-01

    Objective To estimate the cost-effectiveness of visual acuity screening performed in primary care settings and of dilated eye evaluations performed by an eye care professional among new Medicare enrollees with no diagnosed eye disorders. Medicare currently reimburses visual acuity screening for new enrollees during their initial preventive primary care health check, but dilated eye evaluations may be a more cost-effective policy. Design Monte Carlo cost-effectiveness simulation model with a total of 50 000 simulated patients with demographic characteristics matched to persons 65 years of age in the US population. Results Compared with no screening policy, dilated eye evaluations increased quality-adjusted life-years (QALYs) by 0.008 (95% credible interval [CrI], 0.005–0.011) and increased costs by $94 (95% CrI, −$35 to $222). A visual acuity screening increased QALYs in less than 95% of the simulations (0.001 [95% CrI, −0.002 to 0.004) and increased total costs by $32 (95% CrI, −$97 to $159) per person. The incremental cost-effectiveness ratio of a visual acuity screening and an eye examination compared with no screening were $29 000 and $12 000 per QALY gained, respectively. At a willingness-to-pay value of $15 000 or more per QALY gained, a dilated eye evaluation was the policy option most likely to be cost-effective. Conclusions The currently recommended visual acuity screening showed limited efficacy and cost-effectiveness compared with no screening. In contrast, a new policy of reimbursement for Welcome to Medicare dilated eye evaluations was highly cost-effective. PMID:22232367

  6. Interspecific competition among Hawaiian forest birds

    USGS Publications Warehouse

    Mountainspring, S.; Scott, J.M.

    1985-01-01

    The object of this study was to determine whether interspecific competition modified local geographic distribution, after taking into account the effect of habitat structure. The tendencies for 14 passerine birds to have positive or negative associations were examined, using 7861 sample points in seven native forests on the islands of Hawaii, Maui, and Kauai. All birds were at least partly insectivorous and were fairly common in forested areas, although some fed chiefly on nectar or fruit. Species-pairs were classified as primary or secondary potential competitors based on general dietary similarity. To evaluate the association between species and to account for the effect of individual species habitat preferences, partial correlations were computed for each species-pair in a study area from the simple correlations between the species and 26 habitat variables plus two quadratic terms to represent nonlinearity. The partial correlations represented a short-term ('instantaneous') assessment of the strength of competitive interactions, and did not reflect the accumulation of competitive displacement through time. Of 170 partial correlations in the analysis, only 10 indicated significant negative association. The general pattern was of positive association (76 significantly positive partials), which probably resulted from flocking and from attraction of birds to areas of resource superabundance. Two species showed consistent patterns of negative partial correlations over several adjacent study areas, the Japanese White-eye/Iiwi in montane Hawaii, and the Japanese White-eye/Elepaio in windward Hawaii; both patterns could be reasonably attributed to direct competition. Species-pairs were grouped by the native or exotic status of the component species. Native/exotic pairs had a significantly greater proportion of negative partial correlations (37%) than either native/native pairs (8%) or exotic/exotic pairs (0%). This pattern was consistent across the seven study areas and appeared to reflect the occurrence of interspecific competition along a broad and diffuse ecological 'front' between a co-evolved native avifauna and recently introduced exotic species. The role of competition in the pattern was corroborated by the significantly higher proportion of negative partial correlations among species-pairs of primary potential competitors than among those of secondary potential competitors. Our results suggested that 47% of the primary potential competitors among native/exotic species-pairs may experience at least small depressions in local population density due to competition. Although the negative correlations were for the most part small (average negative r = 0.06), one species could eventually replace another as spatial displacement accumulated through time. The Japanese White-eye appeared to have a principal role in native/exotic interactions, with 62% of the partial correlations between it and native primary potential competitor species being negative. Noteworthy implications were that (1) it was important to account for the habitat responses of individual species when studying the role of interspecific competition in modifying small-scale geographic distribution; (2) competition was frequently sporadic in its geographic occurrence and in the species affected, thus supporting Wiens' (1977) theory of competition; and (3) as a consequence, the role of interspecific competition in modifying distribution may be difficult to detect statistically with small data sets.

  7. Context-specific adaptation of pursuit initiation in humans

    NASA Technical Reports Server (NTRS)

    Takagi, M.; Abe, H.; Hasegawa, S.; Usui, T.; Hasebe, H.; Miki, A.; Zee, D. S.; Shelhauser, M. (Principal Investigator)

    2000-01-01

    PURPOSE: To determine if multiple states for the initiation of pursuit, as assessed by acceleration in the "open-loop" period, can be learned and gated by context. METHODS: Four normal subjects were studied. A modified step-ramp paradigm for horizontal pursuit was used to induce adaptation. In an increasing paradigm, target velocity doubled 230 msec after onset; in a decreasing paradigm, it was halved. In the first experiment, vertical eye position (+/-5 degrees ) was used as the context cue, and the training paradigm (increasing or decreasing) changed with vertical eye position. In the second experiment, with vertical position constant, when the target was red, training was decreasing, and when green, increasing. The average eye acceleration in the first 100 msec of tracking was the index of open-loop pursuit performance. RESULTS: With vertical position as the cue, pursuit adaptation differed between up and down gaze. In some cases, the direction of adaptation was in exact accord with the training stimuli. In others, acceleration increased or decreased for both up and down gaze but always in correct relative proportion to the training stimuli. In contrast, multiple adaptive states were not induced with color as the cue. CONCLUSIONS: Multiple values for the relationship between the average eye acceleration during the initiation of pursuit and target velocity could be learned and gated by context. Vertical position was an effective contextual cue but not target color, implying that useful contextual cues must be similar to those occurring naturally, for example, orbital position with eye muscle weakness.

  8. Microbiology of primary acquired nasolacrimal duct obstruction: simple epiphora, acute dacryocystitis, and chronic dacryocystitis

    PubMed Central

    Pornpanich, Kanograt; Luemsamran, Panitee; Leelaporn, Amornrut; Santisuk, Jiraporn; Tesavibul, Nattaporn; Lertsuwanroj, Buntitar; Vangveeravong, Sumalee

    2016-01-01

    Purpose The aim of this study was to determine the microbiology of primary acquired nasolacrimal duct obstruction (PANDO) and its antimicrobial susceptibilities. Methods Ninety-three patients (100 eyes) diagnosed with PANDO, categorized as acute, chronic dacryocystitis, or simple epiphora, were prospectively enrolled. Lacrimal sac contents were cultured for aerobic and anaerobic bacteria and fungi. Cultured organisms were identified, and antimicrobial susceptibility testing was performed for aerobic bacteria. Results Seventy-nine of the 100 samples were culture positive. One hundred twenty-seven organisms were isolated, and 29 different species were identified. Most microorganisms were Gram-positive bacteria (45 samples or 57.0% of all positive culture samples), whereas Gram-negative bacteria, anaerobic bacteria, and fungi were found in 39 (49.4%), 24 (30.4%), and four samples (5.1%), respectively. The most frequently isolated group was coagulase-negative staphylococci (27.8%), followed by nonspore-forming Gram-positive rods (anaerobe) (17.7%) and Pseudomonas aeruginosa (15.2%). Of the 100 samples, five, 45, and 50 samples were obtained from patients with acute dacryocystitis, chronic dacryocystitis, and simple epiphora, respectively. Subgroup analysis showed that Gram-negative organisms were isolated more frequently from the chronic dacryocystitis subgroup than from the simple epiphora subgroup (P=0.012). Antimicrobial susceptibility testing demonstrated that ciprofloxacin was the most effective drug against all Gram-positive and Gram-negative organisms. Conclusion Patients with PANDO, with or without clinical signs of lacrimal infection, were culture positive. Gram-negative organisms were frequently isolated, which were different from previous studies. Ciprofloxacin was the most effective agent against all Gram-positive and Gram-negative organisms. PMID:26955261

  9. The injured eye

    PubMed Central

    Scott, Robert

    2011-01-01

    Eye injuries come at a high cost to society and are avoidable. Ocular blast injuries can be primary, from the blast wave itself; secondary, from fragments carried by the blast wind; tertiary; due to structural collapse or being thrown against a fixed object; or quaternary, from burns and indirect injuries. Ballistic eye protection significantly reduces the incidence of eye injuries and should be encouraged from an early stage in Military training. Management of an injured eye requires meticulous history taking, evaluation of vision that measures the acuity and if there is a relative pupillary defect as well as careful inspection of the eyes, under anaesthetic if necessary. A lateral canthotomy with cantholysis should be performed immediately if there is a sight-threatening retrobulbar haemorrhage. Systemic antibiotics should be prescribed if there is a suspected penetrating or perforating injury. A ruptured globe should be protected by an eye shield. Primary repair of ruptured globes should be performed in a timely fashion. Secondary procedures will often be required at a later date to achieve sight preservation. A poor initial visual acuity is not a guarantee of a poor final result. The final result can be predicted after approximately 3–4 weeks. Future research in eye injuries attempts to reduce scarring and neuronal damage as well as to promote photoreceptor rescue, using post-transcriptional inhibition of cell death pathways and vaccination to promote neural recovery. Where the sight has been lost sensory substitution of a picture from a spectacle mounted video camera to the touch receptors of the tongue can be used to achieve appreciation of the outside world. PMID:21149360

  10. 76 FR 50220 - Availability of Draft ICCVAM Recommendations on Using Fewer Animals to Identify Chemical Eye...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ... Fewer Animals to Identify Chemical Eye Hazards: Revised Criteria Necessary to Maintain Equivalent Hazard... criteria using results from 3-animal tests that would provide eye hazard classification equivalent to... least 1 positive animal in a 3-animal test to identify eye hazards will provide the same or greater...

  11. Mycoplasma conjunctivae in domestic small ruminants from high mountain habitats in Northern Spain.

    PubMed

    Fernández-Aguilar, Xavier; Cabezón, Oscar; Marco, Ignasi; Mentaberre, Gregorio; Frey, Joachim; Lavín, Santiago; López-Olvera, Jorge R

    2013-12-13

    Infectious keratoconjunctivitis (IKC) is a clinical condition affecting eyes of domestic and wild Caprinae worldwide, and Mycoplasma conjunctivae is considered the primary causative agent of IKC in sheep, goats and wild Caprinae. Domestic ruminants from high mountain habitats share grazing areas with wild mountain ungulates, such as chamois (Rupicapra spp.), Alpine ibex (Capra ibex) and European mouflon (Ovis aries musimon), and domestic sheep seem to act as M. conjunctivae reservoir. In this study, the presence of M. conjunctivae in domestic sheep and goats from the two main mountain ranges of Northern Spain, the Pyrenees and the Cantabrian Mountains, has been investigated. Eye swabs were obtained from 439 domestic small ruminants selected from flocks that seasonally graze in alpine meadows during three consecutive years (2011-2012-2013). Seventy-nine out of the 378 domestic sheep (20.9%) tested positive to a M. conjunctivae specific real time-PCR (rt-PCR) in at least one eye, whereas all the 61 sampled domestic goats were negative. Statistically significant higher prevalence and higher proportion of infected flocks (P < 0.001) was observed in the Pyrenees (25.7%; 12 flocks out of 13), where M. conjunctivae is widespread and probably endemic in domestic sheep, than in the Cantabrian Mountains (7.8%; one flock out of six). Twenty-five sheep (three from the Pyrenees and 22 from the Cantabrian Mountains) which showed clinical signs consistent with infectious keratoconjunctivitis (IKC) were negative by rt-PCR. In contrast, 62 out of the 71 (87.3%) M. conjunctivae-positive sheep from the Pyrenees and the eight positive sheep from the Cantabrian Mountains were asymptomatic. This study provides rt-PCR-based evidences of M. conjunctivae maintenance in domestic sheep, as well as a relationship between prevalence in domestic sheep and previously reported M. conjunctivae and IKC in wild ruminants. Domestic goats do not seem to play an important role in the epidemiology of M. conjunctivae in alpine habitats from Northern Spain.

  12. Eye movements during the Rorschach test in schizophrenia.

    PubMed

    Hori, Yasuko; Fukuzako, Hiroshi; Sugimoto, Yoko; Takigawa, Morikuni

    2002-08-01

    In order to understand relationships between scanning behaviors, characteristics of visual stimuli and the clinical symptoms in schizophrenia, eye movements of 37 schizophrenic patients and 36 controls were recorded using an eye-mark recorder during a free-response period in a Rorschach test. Four cards (I, II, V and VIII) were used. Data were analyzed during 15 s from the presentation of each card. For all cards, the number of eye fixations and the number of eye fixation areas were fewer, and total scanning length and mean scanning length were shorter for schizophrenic patients than for controls. For card II, in the non-popular response group, eye fixation frequency upon area 5 + 6 (red) was higher for schizophrenic patients. For card VIII, in the popular response group, eye fixation frequency upon area 5 + 6 (pink) was lower for schizophrenic patients. For cards II and VIII, the number of eye fixations was inversely correlated with negative symptoms. For card II, total scanning length tended to be inversely correlated with negative symptoms, and mean eye fixation time was correlated with negative symptoms. The number of eye fixation areas was inversely correlated with positive symptoms. For card VIII, eye fixation frequency in a stimulative area tended to be correlated with positive symptoms. Scanning behaviors in schizophrenic patients are affected by characteristics of visual stimuli, and partially by clinical symptoms.

  13. Measure and Analysis of a Gaze Position Using Infrared Light Technique

    DTIC Science & Technology

    2001-10-25

    MEASURE AND ANALYSIS OF A GAZE POSITION USING INFRARED LIGHT TECHNIQUE Z. Ramdane-Cherif1,2, A. Naït-Ali2, J F. Motsch2, M. O. Krebs1 1INSERM E 01-17...also proposes a method to correct head movements. Keywords: eye movement, gaze tracking, visual scan path, spatial mapping. INTRODUCTION The eye gaze ...tracking has been used for clinical purposes to detect illnesses, such as nystagmus , unusual eye movements and many others [1][2][3]. It is also used

  14. Corneal status in primary angle-closure glaucoma with a history of acute attack.

    PubMed

    Chen, Mei-Ju; Liu, Catherine Jui-Ling; Cheng, Ching-Yu; Lee, Shui-Mei

    2012-01-01

    The corneal status of patients with primary angle-closure glaucoma (PACG) with a history of acute attack was investigated. This cross-sectional study included 40 eyes of PACG patients with an earlier documented symptomatic acute angle-closure attack (aPACG), 40 uninvolved fellow eyes of aPACG patients (fPACG), 44 eyes of chronic PACG patients without such a history (cPACG), and 50 eyes of age-matched normal participants. All glaucoma patients had patent peripheral iridotomies with adequate intraocular pressure control. The examinations and recorded parameters included visual acuity, intraocular pressure, gonioscopy, vertical cup-to-disc ratio, specular microscopy, central corneal pachymetry, refraction, corneal curvature radius, anterior chamber depth, axial length, and lens thickness measurements, and the presenting intraocular pressure and the duration of acute angle-closure attack for aPACG eyes. The mean endothelial cell density was 2271±80 cells/mm(2) in aPACG, 2458±79 cells/mm(2) in fPACG, 2379±50 cells/mm(2) in cPACG, and 2559±45 cells/mm(2) in controls. The aPACG eyes had significantly lower endothelial cell density compared with normal eyes (P=0.002). There was no significant difference in endothelial cell density of aPACG eyes compared with fPACG or cPACG eyes. Multivariate analysis showed the duration of the acute attack was the only factor independently associated with corneal endothelial density of aPACG eyes. The mean central corneal thickness of aPACG (549±32 μm) did not differ significantly from control eyes (552±27 μm), cPACG (557±32 μm), and fPACG (553±31 μm) (P=0.911, 0.274, and 0.725, respectively). Corneal curvature radius of aPACG eyes was not significantly different from that of the comparison groups (all P>0.05). Corneal endothelial cell density was significantly reduced in aPACG eyes compared with normal eyes. No significant difference in endothelial cell density of aPACG eyes was noted when compared with fPACG or cPACG eyes. Corneal endothelial cell density was negatively associated with the duration of the acute attack, but was not associated with demographic and biometric characteristics. Central corneal thickness and corneal curvature radius were not associated with an earlier acute angle-closure attack.

  15. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

    PubMed

    Nolan, Winifred P; See, Jovina L; Chew, Paul T K; Friedman, David S; Smith, Scott D; Radhakrishnan, Sunita; Zheng, Ce; Foster, Paul J; Aung, Tin

    2007-01-01

    To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. Prospective observational case series. Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard, specificity of AS-OCT in the dark was 55.4% (95% CI, 45.2-65.2) for detecting individuals with angle closure. Anterior segment OCT is a rapid noncontact method of imaging angle structures. It is highly sensitive in detecting angle closure when compared with gonioscopy. More persons are found to have closed angles with AS-OCT than with gonioscopy.

  16. l-tyrosine induces melanocyte differentiation in novel pink-eyed dilution castaneus mouse mutant showing age-related pigmentation.

    PubMed

    Hirobe, Tomohisa; Ishikawa, Akira

    2015-12-01

    The mouse pink-eyed dilution (oculocutaneous albinism II; p/Oca2(p)) locus is known to control tyrosinase activity, melanin content, and melanosome development in melanocytes. Pink-eyed dilution castaneus (p(cas)/Oca2(p-cas)) is a novel mutant allele on mouse chromosome 7 that arose spontaneously in Indonesian wild mice, Mus musculus castaneus. Mice homozygous for Oca2(p-cas) usually exhibit pink eyes and beige-colored coat on nonagouti C57BL/6 (B6) background. Recently, a novel spontaneous mutation occurred in the progeny between this mutant and B6 mice. The eyes of this novel mutant progressively become black from pink and the coat becomes dark gray from beige with aging. The aim of this study is to clarify whatever differences exist in melanocyte proliferation and differentiation between the ordinary (pink-eyed) and novel (black-eyed) mutant using serum-free primary culture system. The characteristics of melanocyte proliferation and differentiation were investigated by serum-free primary culture system using melanocyte-proliferation medium (MDMD). The proliferation of melanoblasts in MDMD did not differ between the two mice. However, when the epidermal cell suspensions were cultured with MDMD supplemented with l-tyrosine (Tyr), the differentiation of black-eyed melanocytes was greatly induced in a concentration-dependent manner compared with pink-eyed melanocytes. Immunocytochemistry demonstrated that the expression of tyrosinase and tyrosinase-related protein-1 (Tyrp1) was greatly induced or stimulated both in pink-eyed and black-eyed melanocytes, whereas the expression of microphthalmia-associated transcription factor (Mitf) was stimulated only in black-eyed melanocytes. These results suggest that the age-related coat darkening in black-eyed mutant may be caused by the increased ability of melanocyte differentiation dependent on l-Tyr through the upregulation of tyrosinase, Tyrp1, and Mitf. This mutant mouse may be useful for animal model to clarify the mechanisms of age-related pigmentation in human skin, such as melasma and solar lentigines. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. A High Prevalence of Exotropia in Patients With Duane Retraction Syndrome in a Tertiary Eye Care Center in South India.

    PubMed

    Bhate, Manjushree; Sachdeva, Virender; Kekunnaya, Ramesh

    2017-03-01

    To determine the prevalence and clinical characteristics of patients with Duane retraction syndrome presenting with exotropia in a tertiary eye care center. Medical records of 140 patients with Duane retraction syndrome and exotropia (of the total 441 patients with Duane retraction syndrome) seen from 2000 to 2009 were reviewed. Characteristics studied included age at presentation, gender, laterality, manifest primary position, abnormal head posture, ocular motility, and overshoots. Data were collected regarding associated ocular or systemic abnormalities and amblyopia. The mean age of the patients at presentation was 16.96 ± 15.09 years (range: 1 to 70 years). Of the 140 patients with Duane retraction syndrome and exotropia, 59 (42%) were male. Unilateral type I Duane retraction syndrome accounted for 118 (84.2%), type II for 7 (5%), and type III for 10 (7.1%) patients, whereas 5 (3.6%) had Duane retraction syndrome and bilateral exotropia. Duane retraction syndrome was seen in the left eye, right eye, and both eyes in 97 (69%), 37 (26%), and 6 (4%) patients, respectively. Exotropia ranged from 10 to 60 prism diopters. An abnormal head posture was noted in 101 (72%) and upshoot in 26 (18.6%) patients. Reported ocular and systemic abnormalities in these patients included cataract (6), aniridia (1), nasolacrimal duct block (1), and retinal breaks (1). This is an exclusive study on a large series of patients with Duane retraction syndrome and exotropia. Almost one-third of patients with Duane retraction syndrome patients might have exotropia. Although patients with Duane retraction syndrome and exotropia had clinical characteristics and associations similar to those with Duane retraction syndrome and esotropia, there was an increased propensity for overshoots and face turn opposite to the affected eye, which the authors hypothesize to be due to a tight or short lateral rectus muscle. [J Pediatr Ophthalmol Strabismus. 2017;54(2):117-122.]. Copyright 2017, SLACK Incorporated.

  18. The Influence of Eye Closure on Somatosensory Discrimination: A Trade-off Between Simple Perception and Discrimination.

    PubMed

    Götz, Theresa; Hanke, David; Huonker, Ralph; Weiss, Thomas; Klingner, Carsten; Brodoehl, Stefan; Baumbach, Philipp; Witte, Otto W

    2017-06-01

    We often close our eyes to improve perception. Recent results have shown a decrease of perception thresholds accompanied by an increase in somatosensory activity after eye closure. However, does somatosensory spatial discrimination also benefit from eye closure? We previously showed that spatial discrimination is accompanied by a reduction of somatosensory activity. Using magnetoencephalography, we analyzed the magnitude of primary somatosensory (somatosensory P50m) and primary auditory activity (auditory P50m) during a one-back discrimination task in 21 healthy volunteers. In complete darkness, participants were requested to pay attention to either the somatosensory or auditory stimulation and asked to open or close their eyes every 6.5 min. Somatosensory P50m was reduced during a task requiring the distinguishing of stimulus location changes at the distal phalanges of different fingers. The somatosensory P50m was further reduced and detection performance was higher during eyes open. A similar reduction was found for the auditory P50m during a task requiring the distinguishing of changing tones. The function of eye closure is more than controlling visual input. It might be advantageous for perception because it is an effective way to reduce interference from other modalities, but disadvantageous for spatial discrimination because it requires at least one top-down processing stage. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  19. Genetics Home Reference: Sjögren syndrome

    MedlinePlus

    ... in the mouth. In most people with Sjögren syndrome , dry eyes and dry mouth are the primary features of ... or systemic lupus erythematosus , later develop the dry eyes and dry mouth characteristic of Sjögren syndrome . Other autoimmune disorders can also develop after the ...

  20. 77 FR 72226 - Picoxystrobin; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-05

    ... one of the following methods: Federal eRulemaking Portal: http://www.regulations.gov . Follow the... validity, completeness, and reliability as well as the relationship of the results of the studies to human... as demonstrated by the severe eye irritation effect seen in the primary eye irritation study on...

  1. Comparison of contact lens and intraocular lens correction of monocular aphakia during infancy: a randomized clinical trial of HOTV optotype acuity at age 4.5 years and clinical findings at age 5 years.

    PubMed

    Lambert, Scott R; Lynn, Michael J; Hartmann, E Eugenie; DuBois, Lindreth; Drews-Botsch, Carolyn; Freedman, Sharon F; Plager, David A; Buckley, Edward G; Wilson, M Edward

    2014-06-01

    The efficacy and safety of primary intraocular lens (IOL) implantation during early infancy is unknown. To compare the visual outcomes of patients optically corrected with contact lenses vs IOLs following unilateral cataract surgery during early infancy. The Infant Aphakia Treatment Study is a randomized clinical trial with 5 years of follow-up that involved 114 infants with unilateral congenital cataracts at 12 sites. A traveling examiner assessed visual acuity at age 4.5 years. Cataract surgery with or without primary IOL implantation. Contact lenses were used to correct aphakia in patients who did not receive IOLs. Treatment was determined through random assignment. HOTV optotype visual acuity at 4.5 years of age. The median logMAR visual acuity was not significantly different between the treated eyes in the 2 treatment groups (both, 0.90 [20/159]; P = .54). About 50% of treated eyes in both groups had visual acuity less than or equal to 20/200. Significantly more patients in the IOL group had at least 1 adverse event after cataract surgery (contact lens, 56%; IOL, 81%; P = .02). The most common adverse events in the IOL group were lens reproliferation into the visual axis, pupillary membranes, and corectopia. Glaucoma/glaucoma suspect occurred in 35% of treated eyes in the contact lens group vs 28% of eyes in the IOL group (P = .55). Since the initial cataract surgery, significantly more patients in the IOL group have had at least 1 additional intraocular surgery (contact lens, 21%; IOL, 72%; P < .001). There was no significant difference between the median visual acuity of operated eyes in children who underwent primary IOL implantation and those left aphakic. However, there were significantly more adverse events and additional intraoperative procedures in the IOL group. When operating on an infant younger than 7 months of age with a unilateral cataract, we recommend leaving the eye aphakic and focusing the eye with a contact lens. Primary IOL implantation should be reserved for those infants where, in the opinion of the surgeon, the cost and handling of a contact lens would be so burdensome as to result in significant periods of uncorrected aphakia. clinicaltrials.gov Identifier: NCT00212134

  2. A light-up probe with aggregation-induced emission characteristics (AIE) for selective imaging, naked-eye detection and photodynamic killing of Gram-positive bacteria.

    PubMed

    Feng, Guangxue; Yuan, Youyong; Fang, Hu; Zhang, Ruoyu; Xing, Bengang; Zhang, Guanxin; Zhang, Deqing; Liu, Bin

    2015-08-11

    We report the design and synthesis of a red fluorescent AIE light-up probe for selective recognition, naked-eye detection, and image-guided photodynamic killing of Gram-positive bacteria, including vancomycin-resistant Enterococcus strains.

  3. Analysis of the effects of non-supine sleeping positions on the stress, strain, deformation and intraocular pressure of the human eye

    NASA Astrophysics Data System (ADS)

    Volpe, Peter A.

    This thesis presents analytical models, finite element models and experimental data to investigate the response of the human eye to loads that can be experienced when in a non-supine sleeping position. The hypothesis being investigated is that non-supine sleeping positions can lead to stress, strain and deformation of the eye as well as changes in intraocular pressure (IOP) that may exacerbate vision loss in individuals who have glaucoma. To investigate the quasi-static changes in stress and internal pressure, a Fluid-Structure Interaction simulation was performed on an axisymmetrical model of an eye. Common Aerospace Engineering methods for analyzing pressure vessels and hyperelastic structural walls are applied to developing a suitable model. The quasi-static pressure increase was used in an iterative code to analyze changes in IOP over time.

  4. Clinical Verification of Image Warping as a Potential Aid for the Visually Handicapped

    NASA Technical Reports Server (NTRS)

    Loshin, David

    1996-01-01

    The bulk of this research was to designed determine potential of the Programmable Remapper (PR) as a device to enhance vision for the visually handicapped. This research indicated that remapping would have potential as a low vision device if the eye position could be monitored with feedback to specify the proper location of the remapped image. This must be accomplished at high rate so that there is no lag of the image behind the eye position. Since at this time, there is no portable eye monitor device (at a reasonable cost) that will operate under the required conditions, it would not be feasible to continue with remapping experiments for patients with central field defects. However, since patients with peripheral field defects do not have the same eye positioning requirements, they may indeed benefit from this technology. Further investigations must be performed to determine plausibility of this application of remapping.

  5. Mammalian Toxicity of Munition Compounds. Phase 1. Acute Oral Toxicity Primary Skin and Eye Irritation, Dermal Sensitization, and Disposition and Metabolism

    DTIC Science & Technology

    1975-07-22

    Mononitroglycerins Nitrocellulose White Phosphor 20. ABSTRACT (C^nllnu eery and Identify by block number) 0D | jSJ’TJ M73 EDITION OF I NOV 6» IS...White Phosphorus 2. Synthesis of DNGs and MNGs 3. Analysis of Chemicals . C. Acute LD D. Primary Skin and Eye Irritation E. Dermal...by the Radford Army Ammunition Plant (Radford, Virginia). 2. Synthesis of DNGs and MNGs a. 1,2-DNG: to that of Dunstan et al.— The sample was

  6. INFRARED- BASED BLINK DETECTING GLASSES FOR FACIAL PACING: TOWARDS A BIONIC BLINK

    PubMed Central

    Frigerio, Alice; Hadlock, Tessa A; Murray, Elizabeth H; Heaton, James T

    2015-01-01

    IMPORTANCE Facial paralysis remains one of the most challenging conditions to effectively manage, often causing life-altering deficits in both function and appearance. Facial rehabilitation via pacing and robotic technology has great yet unmet potential. A critical first step towards reanimating symmetrical facial movement in cases of unilateral paralysis is the detection of healthy movement to use as a trigger for stimulated movement. OBJECTIVE To test a blink detection system that can be attached to standard eyeglasses and used as part of a closed-loop facial pacing system. DESIGN Standard safety glasses were equipped with an infrared (IR) emitter/detector pair oriented horizontally across the palpebral fissure, creating a monitored IR beam that became interrupted when the eyelids closed. SETTING Tertiary care Facial Nerve Center. PARTICIPANTS 24 healthy volunteers. MAIN OUTCOME MEASURE Video-quantified blinking was compared with both IR sensor signal magnitude and rate of change in healthy participants with their gaze in repose, while they shifted gaze from central to far peripheral positions, and during the production of particular facial expressions. RESULTS Blink detection based on signal magnitude achieved 100% sensitivity in forward gaze, but generated false-detections on downward gaze. Calculations of peak rate of signal change (first derivative) typically distinguished blinks from gaze-related lid movements. During forward gaze, 87% of detected blink events were true positives, 11% were false positives, and 2% false negatives. Of the 11% false positives, 6% were associated with partial eyelid closures. During gaze changes, false blink detection occurred 6.3% of the time during lateral eye movements, 10.4% during upward movements, 46.5% during downward movements, and 5.6% for movements from an upward or downward gaze back to the primary gaze. Facial expressions disrupted sensor output if they caused substantial squinting or shifted the glasses. CONCLUSION AND RELEVANCE Our blink detection system provides a reliable, non-invasive indication of eyelid closure using an invisible light beam passing in front of the eye. Future versions will aim to mitigate detection errors by using multiple IR emitter/detector pairs mounted on the glasses, and alternative frame designs may reduce shifting of the sensors relative to the eye during facial movements. PMID:24699708

  7. [Clinical characteristics of choroidal metastasis].

    PubMed

    Zhang, Hui-rong; Ma, Zhi-zhong; Feng, Yun; Guo, Tong

    2009-04-01

    To study the clinical characteristics of choroidal metastasis (CM) to promote the early diagnosis and differentiate from other choroidal tumors. Retrospective clinical observational cases. All patients with choroidal metastasis underwent ophthalmologic examination including best corrected visual acuity (VA), slit-lamp examination, binocular indirect funduscopy, color photography, fundus fluorescein angiography (FFA), indocyanine-green angiography (ICGA), optical coherence tomography (OCT), A and B scan ultrasound examination, magnetic resonance image (MRI) as well as CT of the thorax, etc. Nine eyes of 5 patients with CM were examined. Unilateral choroidal involvement was present in 1 patient, bilateral in 4 cases. There were 1 case male and 4 case females. The age of these patients ranged from 31 to 56 years, median 45 years. Ocular symptoms included reduced vision in 4 patients and visual distortion in 1 patient. Visual acuity was 20/400- < 20/63 in four eyes; 20/63- < 20/30 in two eyes and >or= 20/30 in three eyes. The primary cancer site was in the lung in 3 patients, in the breast in 1 patient and in the stomach in 1 patient. Fundus characteristics: Typical CM was more often in the plateau-shaped than in the dome-shaped; yellow-white or mottled in color and associated with subretinal fluid and retinal detachment. The tumor was found in the macular area and juxtapapillary area in 6 eyes, in the area between the macula and the equator in 3 eyes. CM was solitary in 5 eyes and showed multiple lesions in 4 eyes. By FA the lesions showed mottled hyperfluorescence in early stage and leakage in late stage. By ICGA the lesion showed blocked fluorescence and hypofluorescence. Choroidal mass showed moderate irregular internal reflectivity in A-scan ultrasound. B-scan showed a plateau-shaped solid mass. MRI examination of the lesion revealed moderate short T1W and T2W signals. The cancer antigen increased to 16.28 and 4.95 microg/L in two cases. CA125 increased to 160.5 kU/L in one case. The choroid is the most common site for metastases. CM may precede the diagnosis of primary tumor. Evaluation of A, B scan ultrasound, CT of thorax and cancer antigen test may be important to exclude primary carcinoma from lung and breast in patients with yellow-white in color, plateau-shaped choroidal lesions, especially in both eyes, and without known metastatic diseases.

  8. Recurrent parotitis as a presentation of primary pediatric Sjögren syndrome.

    PubMed

    Baszis, Kevin; Toib, Dana; Cooper, Megan; French, Anthony; White, Andrew

    2012-01-01

    Parotitis is a common condition seen in the pediatric population, usually as an isolated occurrence associated with viral or bacterial infection. The differential diagnosis expands when recurrent parotitis is encountered. One etiology is primary pediatric Sjögren syndrome (SS), an autoimmune condition typically associated with dryness of the eyes and mouth in adults. Pediatric patients often present with isolated recurrent bilateral parotitis, however, and we describe 4 such cases in children aged 9 to 17 years at presentation. Despite lack of ocular complaints, 3 of these patients had ocular findings on ophthalmologic exam. Our patients also exhibited classic laboratory abnormalities, including positive antinuclear antibody, SS A, and SS B antibodies; presence of rheumatoid factor; and hypergammaglobulinemia. Consideration of SS in the child with recurrent parotitis is important for timely and appropriate referral and treatment. We review the differential diagnosis of parotitis in children as well as the salient features of pediatric SS.

  9. Intraocular lens power selection and positioning with and without intraoperative aberrometry.

    PubMed

    Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H

    2015-04-01

    To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.

  10. Avoidance of a moving threat in the common chameleon (Chamaeleo chamaeleon): rapid tracking by body motion and eye use.

    PubMed

    Lev-Ari, Tidhar; Lustig, Avichai; Ketter-Katz, Hadas; Baydach, Yossi; Katzir, Gadi

    2016-08-01

    A chameleon (Chamaeleo chamaeleon) on a perch responds to a nearby threat by moving to the side of the perch opposite the threat, while bilaterally compressing its abdomen, thus minimizing its exposure to the threat. If the threat moves, the chameleon pivots around the perch to maintain its hidden position. How precise is the body rotation and what are the patterns of eye movement during avoidance? Just-hatched chameleons, placed on a vertical perch, on the side roughly opposite to a visual threat, adjusted their position to precisely opposite the threat. If the threat were moved on a horizontal arc at angular velocities of up to 85°/s, the chameleons co-rotated smoothly so that (1) the angle of the sagittal plane of the head relative to the threat and (2) the direction of monocular gaze, were positively and significantly correlated with threat angular position. Eye movements were role-dependent: the eye toward which the threat moved maintained a stable gaze on it, while the contralateral eye scanned the surroundings. This is the first description, to our knowledge, of such a response in a non-flying terrestrial vertebrate, and it is discussed in terms of possible underlying control systems.

  11. [Can fixation disparity be detected reliably by measurement and correctional techniques according H.J. Haase (MKH)?].

    PubMed

    Gerling, J; de Paz, H; Schroth, V; Bach, M; Kommerell, G

    2000-06-01

    The theory of the "Measuring and Correction Methods of H.-J. Haase" (MCH) states that a small misalignment of one eye, called fixation disparity, indicates a difficulty in overcoming a "vergence position of rest" that is different from ortho position. This difficulty, so the theory, can cause asthenopic complaints, such as headaches, and these complaints can be relieved by prisms. The theory further claims that fixation disparity can be ascertained by a series of tests which depend on the subject's perception. The tests most decisive for the diagnosis of a so-called fixation disparity type 2 consist of stereo displays. The magnitude of the prism that allows the subject to see the test configurations in symmetry is thought to be the one that corrects the "vergence position of rest". Nine subjects with healthy eyes in whom a "fixation disparity type 2" had been diagnosed were selected for the study. Misalignment of the eyes was determined according to the principle of the unilateral cover test. Targets identical for both eyes were presented on the screen of the Polatest E. Then, the target was deleted for one eye and the ensuing position change of the other eye was measured, using the search coil technique. This test was performed both with and without the MCH prism. In all 9 subjects the misalignment was less than 10 minutes of arc, i.e. in the range of normal fixation instability. Averaging across the 9 subjects, the deviation of the eye (misaligned according to MCH) was 0.79 +/- 3.45 minutes of arc in the direction opposed to that predicted by the MCH, a value not significantly different from zero. The MCH prism elicited a fusional vergence movement the magnitude of which corresponded to the magnitude of the MCH prism. Ascertaining fixation disparity with the MCH is unreliable. Accordingly, it appears dubious to correct a "vergence position of rest" on the basis of the MCH.

  12. The effect of simultaneous negative and positive defocus on eye growth and development of refractive state in marmosets.

    PubMed

    Benavente-Perez, Alexandra; Nour, Ann; Troilo, David

    2012-09-21

    We evaluated the effect of imposing negative and positive defocus simultaneously on the eye growth and refractive state of the common marmoset, a New World primate that compensates for either negative and positive defocus when they are imposed individually. Ten marmosets were reared with multizone contact lenses of alternating powers (-5 diopters [D]/+5 D), 50:50 ratio for average pupil of 2.80 mm over the right eye (experimental) and plano over the fellow eye (control) from 10 to 12 weeks. The effects on refraction (mean spherical equivalent [MSE]) and vitreous chamber depth (VC) were measured and compared to untreated, and -5 D and +5 D single vision contact lens-reared marmosets. Over the course of the treatment, pupil diameters ranged from 2.26 to 2.76 mm, leading to 1.5 times greater exposure to negative than positive power zones. Despite this, at different intervals during treatment, treated eyes were on average relatively more hyperopic and smaller than controls (experimental-control [exp-con] mean MSE ± SE +1.44 ± 0.45 D, mean VC ± SE -0.05 ± 0.02 mm) and the effects were similar to those in marmosets raised on +5 D single vision contact lenses (exp-con mean MSE ± SE +1.62 ± 0.44 D. mean VC ± SE -0.06 ± 0.03 mm). Six weeks into treatment, the interocular growth rates in multizone animals were already lower than in -5 D-treated animals (multizone -1.0 ± 0.1 μm/day, -5 D +2.1 ± 0.9 μm/day) and did not change significantly throughout treatment. Imposing hyperopic and myopic defocus simultaneously using concentric contact lenses resulted in relatively smaller and less myopic eyes, despite treated eyes being exposed to a greater percentage of negative defocus. Exposing the retina to combined dioptric powers with multifocal lenses that include positive defocus might be an effective treatment to control myopia development or progression.

  13. Mobile, Multimodal, Label-Free Imaging Probe Analysis of Choroidal Oximetry and Retinal Hypoxia

    DTIC Science & Technology

    2017-12-01

    these same eye injuries. Primary blast-induced injury (PBI), which can occur in eyes that are not punctured or ruptured by the blast, is correlated ...optimization. (1A-F) The component of our PBI- devices, output pressure detection sensor, amplifier, and input pressure panel. (1G) Correlation between...by changing the setting of blast generator. (2A-B) Correlation between output pressure and blast time duration. (2C) After PBI- treatment, the eyes of

  14. Adaptive Neural Mechanism for Listing’s Law Revealed in Patients with Skew Deviation Caused by Brainstem or Cerebellar Lesion

    PubMed Central

    Fesharaki, Maryam; Karagiannis, Peter; Tweed, Douglas; Sharpe, James A.; Wong, Agnes M. F.

    2016-01-01

    Purpose Skew deviation is a vertical strabismus caused by damage to the otolithic–ocular reflex pathway and is associated with abnormal ocular torsion. This study was conducted to determine whether patients with skew deviation show the normal pattern of three-dimensional eye control called Listing’s law, which specifies the eye’s torsional angle as a function of its horizontal and vertical position. Methods Ten patients with skew deviation caused by brain stem or cerebellar lesions and nine normal control subjects were studied. Patients with diplopia and neurologic symptoms less than 1 month in duration were designated as acute (n = 4) and those with longer duration were classified as chronic (n = 10). Serial recordings were made in the four patients with acute skew deviation. With the head immobile, subjects made saccades to a target that moved between straight ahead and eight eccentric positions, while wearing search coils. At each target position, fixation was maintained for 3 seconds before the next saccade. From the eye position data, the plane of best fit, referred to as Listing’s plane, was fitted. Violations of Listing’s law were quantified by computing the “thickness” of this plane, defined as the SD of the distances to the plane from the data points. Results Both the hypertropic and hypotropic eyes in patients with acute skew deviation violated Listing’s and Donders’ laws—that is, the eyes did not show one consistent angle of torsion in any given gaze direction, but rather an abnormally wide range of torsional angles. In contrast, each eye in patients with chronic skew deviation obeyed the laws. However, in chronic skew deviation, Listing’s planes in both eyes had abnormal orientations. Conclusions Patients with acute skew deviation violated Listing’s law, whereas those with chronic skew deviation obeyed it, indicating that despite brain lesions, neural adaptation can restore Listing’s law so that the neural linkage between horizontal, vertical, and torsional eye position remains intact. Violation of Listing’s and Donders’ laws during fixation arises primarily from torsional drifts, indicating that patients with acute skew deviation have unstable torsional gaze holding that is independent of their horizontal–vertical eye positions. PMID:18172094

  15. Site of potential operating microscope light-induced phototoxicity on the human retina during temporal approach eye surgery.

    PubMed

    Pavilack, M A; Brod, R D

    2001-02-01

    To determine the site of focal illumination on the retina of phakic human cadaver eyes from an operating microscope positioned for temporal approach eye surgery. Experimental study. A Zeiss OPMI-6SFR operating microscope (Zeiss Humphrey Systems, Dublin, CA) was positioned over two phakic human cadaver eyes to measure the site of the focal illumination on the retina by directly observing the illumination on the posterior scleral surface of the globe. External localization of the foveola was made by direct observation using scleral indentation and indirect ophthalmoscopy. Various combinations of microscope angulation and field of view were analyzed. Distance of focal illumination from the operating room microscope relative to the foveola was measured. The diameter of the "hot spot" of focal illumination on the retina was 4.0 mm. With the eye positioned straight ahead and the level operating room microscope positioned for temporal approach eye surgery, the center of retinal illumination was 0.9 and 1.4 mm nasal relative to the foveola when the microscope field of view was centered over the cornea and temporal limbus, respectively. With the microscope angled 5, 10, 15, and 20 degrees temporally (oculars tilted toward surgeon), the center of the illumination was displaced nasal to the foveola by 1.1, 1.5, 3.8, and 5.1 mm, respectively, when the field of view was centered over the cornea and 1.5, 2.6, 4.7, and 6.0 mm, respectively, nasal to the foveola when centered over the temporal limbus. Retinal illumination from an operating microscope positioned for temporal approach eye surgery has the potential for light-induced injury to the fovea. Angulation of the operating microscope by up to 10 degrees temporally when the microscope field of view was centered over the cornea and up to 5 degrees temporally when centered over the temporal limbus was not adequate to displace the focal illumination off the foveola when the eye was in the straight-ahead position. Tilting the operating microscope 15 degrees or more temporally when centered on the pupil and 10 degrees or more when centered over the temporal limbus should safely displace the retinal light exposure away from the fovea during temporal approach surgery. Suggestions for reducing the risk of iatrogenic phototoxicity are reviewed.

  16. Temporal Dynamics of Ocular Position Dependence of the Initial Human Vestibulo-ocular Reflex

    PubMed Central

    Crane, Benjamin T.; Tian, Junru; Demer, Joseph L.

    2007-01-01

    Purpose While an ideal vestibulo-ocular reflex (VOR) generates ocular rotations compensatory for head motion, during visually guided movements, Listing’s Law (LL) constrains the eye to rotational axes lying in Listing’s Plane (LP). The present study was conducted to explore the recent proposal that the VOR’s rotational axis is not collinear with the head’s, but rather follows a time-dependent strategy intermediate between LL and an ideal VOR. Methods Binocular LPs were defined during visual fixation in eight normal humans. The VOR was evoked by a highly repeatable transient whole-body yaw rotation in darkness at a peak acceleration of 2800 deg/s2. Immediately before rotation, subjects regarded targets 15 or 500 cm distant located at eye level, 20° up, or 20° down. Eye and head responses were compared with LL predictions in the position and velocity domains. Results LP orientation varied both among subjects and between individual subject’s eyes, and rotated temporally with convergence by 5 ± 5° (±SEM). In the position domain, the eye compensated for head displacement even when the head rotated out of LP. Even within the first 20 ms from onset of head rotation, the ocular velocity axis tilted relative to the head axis by 30% ± 8% of vertical gaze position. Saccades increased this tilt. Regardless of vertical gaze position, the ocular rotation axis tilted backward 4° farther in abduction than in adduction. There was also a binocular vertical eye velocity transient and lateral tilt of the ocular axis. Conclusions These disconjugate, short-latency axis perturbations appear intrinsic to the VOR and may have neural or mechanical origins. PMID:16565376

  17. A randomized, multicenter phase 3 study comparing 2% rebamipide (OPC-12759) with 0.1% sodium hyaluronate in the treatment of dry eye.

    PubMed

    Kinoshita, Shigeru; Oshiden, Kazuhide; Awamura, Saki; Suzuki, Hiroyuki; Nakamichi, Norihiro; Yokoi, Norihiko

    2013-06-01

    To investigate the efficacy of 2% rebamipide ophthalmic suspension compared with 0.1% sodium hyaluronate ophthalmic solution for the treatment of patients with dry eye. Randomized, multicenter, active-controlled parallel-group study. One hundred eighty-eight patients with dry eye. Following a 2-week screening period, patients were allocated randomly to receive 2% rebamipide or 0.1% sodium hyaluronate, administered as 1 drop in each eye 4 or 6 times daily, respectively, for 4 weeks. There were 2 primary end points: changes in the fluorescein corneal staining (FCS) score to determine noninferiority of 2% rebamipide and changes in the lissamine green conjunctival staining (LGCS) score to determine superiority. Secondary objective end points were Schirmer's test results and tear film breakup time (TBUT). Secondary subjective end points were dry eye-related ocular symptoms (foreign body sensation, dryness, photophobia, eye pain, and blurred vision) score and the patients' overall treatment impression score. In the primary analysis, the mean change from baseline in FCS scores verified noninferiority, indicated significant improvement, and, in LGCS scores, verified the superiority of 2% rebamipide to 0.1% sodium hyaluronate. Values for the Schirmer's test and TBUT were comparable between the 2 groups. For 2 dry eye-related ocular symptoms--foreign body sensation and eye pain--2% rebamipide showed significant improvements over 0.1% sodium hyaluronate. Patients had a significantly more favorable impression of 2% rebamipide than of 0.1% sodium hyaluronate; 64.5% rated treatment as improved or markedly improved versus 34.7%, respectively. No serious adverse events were observed. Administration of 2% rebamipide was effective in improving both the objective signs and subjective symptoms of dry eye. Those findings, in addition to the well-tolerated profile of 2% rebamipide, clearly show that it is an effective therapeutic method for dry eye. Proprietary or commercial disclosure may be found after the references. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Relationship between relative lens position and appositional closure in eyes with narrow angles.

    PubMed

    Otori, Yasumasa; Tomita, Yuki; Hamamoto, Ayumi; Fukui, Kanae; Usui, Shinichi; Tatebayashi, Misako

    2011-03-01

    To investigate the relationship between relative lens position (RLP) and appositional closure in eyes with narrow angles. Ultrasound biomicroscopy (UBM) was used to measure anterior chamber depth (ACD) and lens thickness (LT), and the IOLMaster to measure axial length (AL). The number of quadrants with appositional closure was assessed by UBM under dark conditions. The RLP was calculated thus: RLP = 10 × (ACD + 0.5 LT) /AL. This study comprised 30 consecutive patients (30 eyes) with narrow-angle eyes defined as Shaffer grade 2 or lower and without peripheral anterior synechiae (24 women, 6 men; mean age ± SD, 67.3 ± 10.4 years; range, 42-87 years). Under dark conditions, 66.7% of the eyes with narrow angles showed appositional closure in at least one quadrant. Of the various ocular biometric parameters, only the RLP significantly decreased with appositional closure in at least one quadrant (P = 0.005). A decrease in the RLP can be predictive of appositional closure for narrow-angle eyes under dark conditions.

  19. Enduring critical period plasticity visualized by transcranial flavoprotein imaging in mouse primary visual cortex.

    PubMed

    Tohmi, Manavu; Kitaura, Hiroki; Komagata, Seiji; Kudoh, Masaharu; Shibuki, Katsuei

    2006-11-08

    Experience-dependent plasticity in the visual cortex was investigated using transcranial flavoprotein fluorescence imaging in mice anesthetized with urethane. On- and off-responses in the primary visual cortex were elicited by visual stimuli. Fluorescence responses and field potentials elicited by grating patterns decreased similarly as contrasts of visual stimuli were reduced. Fluorescence responses also decreased as spatial frequency of grating stimuli increased. Compared with intrinsic signal imaging in the same mice, fluorescence imaging showed faster responses with approximately 10 times larger signal changes. Retinotopic maps in the primary visual cortex and area LM were constructed using fluorescence imaging. After monocular deprivation (MD) of 4 d starting from postnatal day 28 (P28), deprived eye responses were suppressed compared with nondeprived eye responses in the binocular zone but not in the monocular zone. Imaging faithfully recapitulated a critical period for plasticity with maximal effects of MD observed around P28 and not in adulthood even under urethane anesthesia. Visual responses were compared before and after MD in the same mice, in which the skull was covered with clear acrylic dental resin. Deprived eye responses decreased after MD, whereas nondeprived eye responses increased. Effects of MD during a critical period were tested 2 weeks after reopening of the deprived eye. Significant ocular dominance plasticity was observed in responses elicited by moving grating patterns, but no long-lasting effect was found in visual responses elicited by light-emitting diode light stimuli. The present results indicate that transcranial flavoprotein fluorescence imaging is a powerful tool for investigating experience-dependent plasticity in the mouse visual cortex.

  20. Non-Orthogonal Corneal Astigmatism among Normal and Keratoconic Brazilian and Chinese populations.

    PubMed

    Abass, Ahmed; Clamp, John; Bao, FangJun; Ambrósio, Renato; Elsheikh, Ahmed

    2018-06-01

    To investigate the prevalence of non-orthogonal astigmatism among normal and keratoconic Brazilian and Chinese populations. Topography data were obtained using the Pentacam High Resolution (HR) system ® from 458 Brazilian (aged 35.6 ± 15.8 years) and 505 Chinese (aged 31.6 ± 10.8 years) eyes with no history of keratoconus or refractive surgery, and 314 Brazilian (aged 24.2 ± 5.7 years) and 74 Chinese (aged 22.0 ± 5.5 years) keratoconic eyes. Orthogonal values of optical flat and steep powers were determined by finding the angular positions of two perpendicular meridians that gave the maximum difference in power. Additionally, the angular positions of the meridians with the minimum and maximum optical powers were located while being unrestricted by the usual orthogonality assumption. Eyes were determined to have non-orthogonal astigmatism if the angle between the two meridians with maximum and minimum optical power deviated by more than 5° from 90°. Evidence of non-orthogonal astigmatism was found in 39% of the Brazilian keratoconic eyes, 26% of the Chinese keratoconic eyes, 29% of the Brazilian normal eyes and 20% of the Chinese normal eyes. The large percentage of participants with non-orthogonal astigmatism in both normal and keratoconic eyes illustrates the need for the common orthogonality assumption to be reviewed when correcting for astigmatism. The prevalence of non-orthogonality should be considered by expanding the prescription system to consider the two power meridians and their independent positions.

  1. Air Bubble-Induced High Intraocular Pressure After Descemet Membrane Endothelial Keratoplasty.

    PubMed

    Röck, Daniel; Bartz-Schmidt, Karl Ulrich; Röck, Tobias; Yoeruek, Efdal

    2016-08-01

    To investigate the incidence and risk factors of pupillary block caused by an air bubble in the anterior chamber in the early postoperative period after Descemet membrane endothelial keratoplasty (DMEK). A retrospective review was conducted in 306 eyes that underwent DMEK from September 2009 through October 2014 at the Tübingen Eye Hospital. Intraocular pressure (IOP) elevation was defined as a spike above 30 mm Hg. In the first 190 eyes, an intraoperative peripheral iridectomy was performed at the 12-o'clock position and in the other 116 eyes at the 6-o'clock position. If possible, reasons for IOP elevation were identified. For all eyes, preoperative and postoperative slit-lamp examinations and IOP measurements were performed. Overall, 30 eyes (9.8%) showed a postoperative IOP elevation within the first postoperative day. The incidence of IOP elevation was 13.9% (5/36) in the triple DMEK group, and 2 of 5 phakic eyes (40%) developed an air bubble-induced IOP elevation. All eyes presented with a de novo IOP elevation, associated in 25 patients with pupillary block from air anterior to iris and in 5 patients with angle closure from air migration posterior to the iris. All of them had an iridectomy at the 12-o'clock position. A postoperative pupillary block with IOP elevation caused by the residual intraoperative air bubble may be an important complication that could be avoided by close and frequent observations, especially in the first postoperative hours and by an inferior peripheral iridectomy and an air bubble with a volume of ≤80% of the anterior chamber.

  2. Eye tracking detects disconjugate eye movements associated with structural traumatic brain injury and concussion.

    PubMed

    Samadani, Uzma; Ritlop, Robert; Reyes, Marleen; Nehrbass, Elena; Li, Meng; Lamm, Elizabeth; Schneider, Julia; Shimunov, David; Sava, Maria; Kolecki, Radek; Burris, Paige; Altomare, Lindsey; Mehmood, Talha; Smith, Theodore; Huang, Jason H; McStay, Christopher; Todd, S Rob; Qian, Meng; Kondziolka, Douglas; Wall, Stephen; Huang, Paul

    2015-04-15

    Disconjugate eye movements have been associated with traumatic brain injury since ancient times. Ocular motility dysfunction may be present in up to 90% of patients with concussion or blast injury. We developed an algorithm for eye tracking in which the Cartesian coordinates of the right and left pupils are tracked over 200 sec and compared to each other as a subject watches a short film clip moving inside an aperture on a computer screen. We prospectively eye tracked 64 normal healthy noninjured control subjects and compared findings to 75 trauma subjects with either a positive head computed tomography (CT) scan (n=13), negative head CT (n=39), or nonhead injury (n=23) to determine whether eye tracking would reveal the disconjugate gaze associated with both structural brain injury and concussion. Tracking metrics were then correlated to the clinical concussion measure Sport Concussion Assessment Tool 3 (SCAT3) in trauma patients. Five out of five measures of horizontal disconjugacy were increased in positive and negative head CT patients relative to noninjured control subjects. Only one of five vertical disconjugacy measures was significantly increased in brain-injured patients relative to controls. Linear regression analysis of all 75 trauma patients demonstrated that three metrics for horizontal disconjugacy negatively correlated with SCAT3 symptom severity score and positively correlated with total Standardized Assessment of Concussion score. Abnormal eye-tracking metrics improved over time toward baseline in brain-injured subjects observed in follow-up. Eye tracking may help quantify the severity of ocular motility disruption associated with concussion and structural brain injury.

  3. Eye Tracking Detects Disconjugate Eye Movements Associated with Structural Traumatic Brain Injury and Concussion

    PubMed Central

    Ritlop, Robert; Reyes, Marleen; Nehrbass, Elena; Li, Meng; Lamm, Elizabeth; Schneider, Julia; Shimunov, David; Sava, Maria; Kolecki, Radek; Burris, Paige; Altomare, Lindsey; Mehmood, Talha; Smith, Theodore; Huang, Jason H.; McStay, Christopher; Todd, S. Rob; Qian, Meng; Kondziolka, Douglas; Wall, Stephen; Huang, Paul

    2015-01-01

    Abstract Disconjugate eye movements have been associated with traumatic brain injury since ancient times. Ocular motility dysfunction may be present in up to 90% of patients with concussion or blast injury. We developed an algorithm for eye tracking in which the Cartesian coordinates of the right and left pupils are tracked over 200 sec and compared to each other as a subject watches a short film clip moving inside an aperture on a computer screen. We prospectively eye tracked 64 normal healthy noninjured control subjects and compared findings to 75 trauma subjects with either a positive head computed tomography (CT) scan (n=13), negative head CT (n=39), or nonhead injury (n=23) to determine whether eye tracking would reveal the disconjugate gaze associated with both structural brain injury and concussion. Tracking metrics were then correlated to the clinical concussion measure Sport Concussion Assessment Tool 3 (SCAT3) in trauma patients. Five out of five measures of horizontal disconjugacy were increased in positive and negative head CT patients relative to noninjured control subjects. Only one of five vertical disconjugacy measures was significantly increased in brain-injured patients relative to controls. Linear regression analysis of all 75 trauma patients demonstrated that three metrics for horizontal disconjugacy negatively correlated with SCAT3 symptom severity score and positively correlated with total Standardized Assessment of Concussion score. Abnormal eye-tracking metrics improved over time toward baseline in brain-injured subjects observed in follow-up. Eye tracking may help quantify the severity of ocular motility disruption associated with concussion and structural brain injury. PMID:25582436

  4. Progressive Decrease of Peripapillary Angioflow Vessel Density During Structural and Visual Field Progression in Early Primary Open-angle Glaucoma.

    PubMed

    Holló, Gábor

    2017-07-01

    To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.

  5. The effect of binocular eye position and head rotation plane on the human torsional vestibuloocular reflex.

    PubMed

    Migliaccio, Americo A; Della Santina, Charles C; Carey, John P; Minor, Lloyd B; Zee, David S

    2006-08-01

    We examined how the gain of the torsional vestibulo-ocular reflex (VOR) (defined as the instantaneous eye velocity divided by inverted head velocity) in normal humans is affected by eye position, target distance, and the plane of head rotation. In six normal subjects we measured three-dimensional (3D) eye and head rotation axes using scleral search coils, and 6D head position using a magnetic angular and linear position measurement device, during low-amplitude (approximately 20 degrees ), high-velocity (approximately 200 degrees/s), high-acceleration (approximately 4000 degrees /s2) rapid head rotations or 'impulses.' Head impulses were imposed manually and delivered in five planes: yaw (horizontal canal plane), pitch, roll, left anterior-right posterior canal plane (LARP), and right anterior-left posterior canal plane (RALP). Subjects were instructed to fix on one of six targets at eye level. Targets were either straight-ahead, 20 degrees left or 20 degrees right from midline, at distance 15 or 124 cm from the subject. Two subjects also looked at more eccentric targets, 30 degrees left or 30 degrees right from midline. We found that the vertical and horizontal VOR gains increased with the proximity of the target to the subject. Previous studies suggest that the torsional VOR gain should decrease with target proximity. We found, however, that the torsional VOR gain did not change for all planes of head rotation and for both target distances. We also found a dynamic misalignment of the vertical positions of the eyes during the torsional VOR, which was greatest during near viewing with symmetric convergence. This dynamic vertical skew during the torsional VOR arises, in part, because when the eyes are converged, the optical axes are not parallel to the naso-occipital axes around which the eyes are rotating. In five of six subjects, the average skew ranged 0.9 degrees -2.9 degrees and was reduced to <0.4 degrees by a 'torsional' quick-phase (around the naso-occipital axis) occurring <110 ms after the onset of the impulse. We propose that the torsional quick-phase mechanism during the torsional VOR could serve at least three functions: (1) resetting the retinal meridians closer to their usual orientation in the head, (2) correcting for the 'skew' deviation created by misalignment between the axes around which the eyes are rotating and the line of sight, and (3) taking the eyes back toward Listing's plane.

  6. Three-dimensional ocular kinematics during eccentric rotations: evidence for functional rather than mechanical constraints

    NASA Technical Reports Server (NTRS)

    Angelaki, Dora E.

    2003-01-01

    Previous studies have reported that the translational vestibuloocular reflex (TVOR) follows a three-dimensional (3D) kinematic behavior that is more similar to visually guided eye movements, like pursuit, rather than the rotational VOR (RVOR). Accordingly, TVOR rotation axes tilted with eye position toward an eye-fixed reference frame rather than staying relatively fixed in the head like in the RVOR. This difference arises because, contrary to the RVOR where peripheral image stability is functionally important, the TVOR like pursuit and saccades cares to stabilize images on the fovea. During most natural head and body movements, both VORs are simultaneously activated. In the present study, we have investigated in rhesus monkeys the 3D kinematics of the combined VOR during yaw rotation about eccentric axes. The experiments were motivated by and quantitatively compared with the predictions of two distinct hypotheses. According to the first (fixed-rule) hypothesis, an eye-position-dependent torsion is computed downstream of a site for RVOR/TVOR convergence, and the combined VOR axis would tilt through an angle that is proportional to gaze angle and independent of the relative RVOR/TVOR contributions to the total eye movement. This hypothesis would be consistent with the recently postulated mechanical constraints imposed by extraocular muscle pulleys. According to the second (image-stabilization) hypothesis, an eye-position-dependent torsion is computed separately for the RVOR and the TVOR components, implying a processing that takes place upstream of a site for RVOR/TVOR convergence. The latter hypothesis is based on the functional requirement that the 3D kinematics of the combined VOR should be governed by the need to keep images stable on the fovea with slip on the peripheral retina being dependent on the different functional goals of the two VORs. In contrast to the fixed-rule hypothesis, the data demonstrated a variable eye-position-dependent torsion for the combined VOR that was different for synergistic versus antagonistic RVOR/TVOR interactions. Furthermore, not only were the eye-velocity tilt slopes of the combined VOR as much as 10 times larger than what would be expected based on extraocular muscle pulley location, but also eye velocity during antagonistic RVOR/TVOR combinations often tilted opposite to gaze. These results are qualitatively and quantitatively consistent with the image-stabilization hypothesis, suggesting that the eye-position-dependent torsion is computed separately for the RVOR and the TVOR and that the 3D kinematics of the combined VOR are dependent on functional rather than mechanical constraints.

  7. A mouse model of ocular blast injury that induces closed globe anterior and posterior pole damage

    PubMed Central

    Hines-Beard, Jessica; Marchetta, Jeffrey; Gordon, Sarah; Chaum, Edward; Geisert, Eldon E.; Rex, Tonia S.

    2012-01-01

    We developed and characterized a mouse model of primary ocular blast injury. The device consists of: a pressurized air tank attached to a regulated paintball gun with a machined barrel; a chamber that protects the mouse from direct injury and recoil, while exposing the eye; and a secure platform that enables fine, controlled movement of the chamber in relation to the barrel. Expected pressures were calculated and the optimal pressure transducer, based on the predicted pressures, was positioned to measure output pressures at the location where the mouse eye would be placed. Mice were exposed to one of three blast pressures (23.6, 26.4, or 30.4psi). Gross pathology, intraocular pressure, optical coherence tomography, and visual acuity were assessed 0, 3, 7, 14, and 28 days after exposure. Contralateral eyes and non-blast exposed mice were used as controls. We detected increased damage with increased pressures and a shift in the damage profile over time. Gross pathology included corneal edema, corneal abrasions, and optic nerve avulsion. Retinal damage was detected by optical coherence tomography and a deficit in visual acuity was detected by optokinetics. Our findings are comparable to those identified in Veterans of the recent wars with closed eye injuries as a result of blast exposure. In summary, this is a relatively simple system that creates injuries with features similar to those seen in patients with ocular blast trauma. This is an important new model for testing the short-term and long-term spectrum of closed globe blast injuries and potential therapeutic interventions. PMID:22504073

  8. An international survey of classification and treatment choices for group D retinoblastoma

    PubMed Central

    Scelfo, Christina; Francis, Jasmine H; Khetan, Vikas; Jenkins, Thomas; Marr, Brian; Abramson, David H; Shields, Carol L; Pe'er, Jacob; Munier, Francis; Berry, Jesse; Harbour, J. William; Yarovoy, Andrey; Lucena, Evandro; Murray, Timothy G; Bhagia, Pooja; Paysse, Evelyn; Tuncer, Samuray; Chantada, Guillermo L; Moll, Annette C; Ushakova, Tatiana; Plager, David A; Ziyovuddin, Islamov; Leal, Carlos A; Materin, Miguel A; Ji, Xun-Da; Cursino, Jose W; Polania, Rodrigo; Kiratli, Hayyam; All-Ericsson, Charlotta; Kebudi, Rejin; Honavar, Santosh G; Vishnevskia-Dai, Vicktoria; Epelman, Sidnel; Daniels, Anthony B; Ling, Jeanie D; Traore, Fousseyni; Ramirez-Ortiz, Marco A

    2017-01-01

    AIM To determine which IIRC scheme was used by retinoblastoma centers worldwide and the percentage of D eyes treated primarily with enucleation versus globe salvaging therapies as well as to correlate trends in treatment choice to IIRC version used and geographic region. METHODS An anonymized electronic survey was offered to 115 physicians at 39 retinoblastoma centers worldwide asking about IIRC classification schemes and treatment patterns used between 2008 and 2012. Participants were asked to record which version of the IIRC was used for classification, how many group D eyes were diagnosed, and how many eyes were treated with enucleation versus globe salvaging therapies. Averages of eyes per treatment modality were calculated and stratified by both IIRC version and geographic region. Statistical significance was determined by Chi-square, ANOVA and Kruskal-Wallis tests using Prism. RESULTS The survey was completed by 29% of physicians invited to participate. Totally 1807 D eyes were diagnosed. Regarding IIRC system, 27% of centers used the Children's Hospital of Los Angeles (CHLA) version, 33% used the Children's Oncology Group (COG) version, 23% used the Philadelphia version, and 17% were unsure. The rate for primary enucleation varied between 0 and 100% and the mean was 29%. By IIRC version, primary enucleation rates were: Philadelphia, 8%; COG, 34%; and CHLA, 37%. By geographic region, primary enucleation rates were: Latin America, 57%; Asia, 40%; Europe, 36%; Africa, 10%, US, 8%; and Middle East, 8%. However, systemic chemoreduction was used more often than enucleation in all regions except Latin America with a mean of 57% per center (P<0.0001). CONCLUSION Worldwide there is no consensus on which IIRC version is used, systemic chemoreduction was the most frequently used initial treatment during the study period followed by enucleation and primary treatment modality, especially enucleation, varied greatly with regards to IIRC version used and geographic region. PMID:28730089

  9. [Correction of refractive errors in patients with strabismus. Part I. Clinical problems associated with refraction, accommodation and convergence].

    PubMed

    Tokarz-Sawińska, Ewa

    2012-01-01

    In Part I the problems associated with refraction, accommodation and convergence and their role in proper eye position/visual alignment of the eyes as well as convergent, divergent and vertical alignment of the eyes have been described.

  10. Primary intraocular ancient schwannoma: a case report and review of the literature.

    PubMed

    Mortuza, Shaikh; Esmaeli, Bita; Bell, Diana

    2014-04-01

    Schwannomas comprise 8% to 10% of all primary intracranial tumors. Primary intraorbital schwannomas are rare, accounting for 1% to 2% of all intracranial tumors. Schwannomas arise from Schwann cells in the myelin sheaths of sensory and cranial nerves. We present the case of a 56-year-old white man blind since 1970 who presented to an outside hospital for a painful right eye. Physicians identified no clinical or radiologic features of neurofibromatosis. The patient underwent enucleation; the final pathologic diagnosis was ancient schwannoma. We describe herein a case of intrascleral schwannoma with ancient changes arising within the globe of the right eye occupying the subretinal space and completely replacing the vitreous body. Copyright © 2013 Wiley Periodicals, Inc.

  11. Preschool children's vision screening in New Zealand: a retrospective evaluation of referral accuracy.

    PubMed

    Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S

    2015-11-27

    To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Retrospective longitudinal study. B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Positive predictive value of the preschool vision screening programme. Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Depression screening among older adults attending low-vision rehabilitation and eye-care services: Characteristics of those who screen positive and client acceptability of screening.

    PubMed

    Holloway, Edith E; Sturrock, Bonnie A; Lamoureux, Ecosse L; Keeffe, Jill E; Rees, Gwyneth

    2015-12-01

    To investigate characteristics associated with screening positive for depressive symptoms among older adults accessing low-vision rehabilitation and eye-care services and to determine client acceptability of depression screening using the Patient Health Questionnaire-2 (PHQ-2) in these settings. One-hundred and twenty-four older adults (mean = 77.02 years, SD = 9.12) attending low-vision rehabilitation and eye-care services across Australia were screened for depression and invited to complete a telephone-administered questionnaire to determine characteristics associated with depressive symptoms and client acceptability of screening in these settings. Thirty-seven per cent (n = 46/124) of participants screened positive for depressive symptoms, and the majority considered the new depression screening method to be a 'good idea' in vision services (85%). Severe vision loss (<6/60 in the better eye) was associated with an increased odds of screening positive for depressive symptoms (odds ratio 2.37; 95% confidence interval 1.08-6.70) even after adjusting for potential confounders. Participants who screened positive had a preference for 'talking' therapy or a combination of medication and 'talking therapy' delivered within their own home (73%) or via telephone (67%). The PHQ-2 appears to be an acceptable method for depression screening in eye-care settings among older adults. Targeted interventions that incorporate home-based or telephone delivered therapy sessions may improve outcomes for depression in this group. © 2014 ACOTA.

  13. Eye health programs within remote Aboriginal communities in Australia: a review of the literature.

    PubMed

    Durkin, Shane R

    2008-11-01

    To review the literature regarding the most sustainable and culturally appropriate ways in which to implement eye health care programs within remote Aboriginal communities in Australia from a primary health care perspective. The search included letters, editorials and papers (published and unpublished) from January 1955 to April 2006. The search revealed 1,106,758 papers, books and other related material. The relevancy of this material was determined by abstract and 378 relevant articles were reviewed in their entirety. After reading the relevant articles and the interview transcripts the themes that emerged from each source were extracted. The ten areas to consider include: clinical practice and access, sustainability, regional-based programs, information technology systems, health worker training, self-determination, cultural and language barriers, funding body responsibilities, embedding specialist programs in primary care services, and other considerations. Further research needs to be undertaken within Aboriginal communities in the area of primary eye health care and barriers to the acceptance of treatment. This may be undertaken using more interactive research methods such as cooperative and narrative inquiry.

  14. Single neural code for blur in subjects with different interocular optical blur orientation

    PubMed Central

    Radhakrishnan, Aiswaryah; Sawides, Lucie; Dorronsoro, Carlos; Peli, Eli; Marcos, Susana

    2015-01-01

    The ability of the visual system to compensate for differences in blur orientation between eyes is not well understood. We measured the orientation of the internal blur code in both eyes of the same subject monocularly by presenting pairs of images blurred with real ocular point spread functions (PSFs) of similar blur magnitude but varying in orientations. Subjects assigned a level of confidence to their selection of the best perceived image in each pair. Using a classification-images–inspired paradigm and applying a reverse correlation technique, a classification map was obtained from the weighted averages of the PSFs, representing the internal blur code. Positive and negative neural PSFs were obtained from the classification map, representing the neural blur for best and worse perceived blur, respectively. The neural PSF was found to be highly correlated in both eyes, even for eyes with different ocular PSF orientations (rPos = 0.95; rNeg = 0.99; p < 0.001). We found that in subjects with similar and with different ocular PSF orientations between eyes, the orientation of the positive neural PSF was closer to the orientation of the ocular PSF of the eye with the better optical quality (average difference was ∼10°), while the orientation of the positive and negative neural PSFs tended to be orthogonal. These results suggest a single internal code for blur with orientation driven by the orientation of the optical blur of the eye with better optical quality. PMID:26114678

  15. Clinical presentation of familial exudative vitreoretinopathy.

    PubMed

    Ranchod, Tushar M; Ho, Lawrence Y; Drenser, Kimberly A; Capone, Antonio; Trese, Michael T

    2011-10-01

    To describe the clinical characteristics, staging and presentation of patients with familial exudative vitreoretinopathy (FEVR) in our clinical practice over the last 25 years. Case series, retrospective review. We included 273 eyes of 145 patients. Data collected from charts included gender, gestational age at birth, birthweight, age at presentation, referring diagnosis, family history, prior ocular surgery, and clinical presentation in each eye. Eyes with invasive posterior segment procedures before initial presentation were excluded. Demographics on presentation and clinical staging. Patients were slightly male predominant (57%) with a mean birthweight of 2.80 kg (range, 740 g-4.76 kg), mean gestational age of 37.8 weeks (range, 25-42), and mean age at presentation of almost 6 years (range, <1 month-49 years). A positive family history of FEVR was obtained in 18% of patients. A positive family history for ocular disease consistent with but not diagnosed as FEVR was obtained in an additional 19%. Stage 1 FEVR was identified in 45 eyes, stage 2 in 33 eyes, stage 3 in 42 eyes, stage 4 in 89 eyes, and stage 5 in 44 eyes. Radial retinal folds were seen in 77 eyes, 64 of which were temporal or inferotemporal in location. The FEVR patient population is remarkable for the wide range of age at presentation, gestational age, and birthweight. Although a positive family history on presentation may support the diagnosis of FEVR, a negative family history is of little help. The majority of retinal folds extended radially in the temporal quadrants, but radial folds were seen in almost all quadrants. Fellow eyes demonstrated a wide variation in symmetry. The presentation of FEVR may mimic the presentation of other pediatric and adult vitreoretinal disorders, and careful examination is often crucial in making the diagnosis of FEVR. The authors have no proprietary or commercial interest in any of the materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. MEASUREMENT OF RADIATION DOSES TO THE EYE LENS DURING ORTHOPEDIC SURGERY USING AN C-ARM X-RAY SYSTEM.

    PubMed

    Suzuki, Akira; Matsubara, Kosuke; Sasa, Yuko

    2018-04-01

    The present study aimed to determine doses delivered to the eye lenses of surgeons while using the inverted-C-arm technique and the protective effect of leaded spectacles during orthopedic surgery. The kerma in air was measured at five positions on leaded glasses positioned near the eye lens and on the neck using small optically stimulated luminescence (OSL) dosemeters. The lens equivalent dose was also measured at the neck using an OSL dosemeter. The maximum equivalent dose to the eye lens and the maximum kerma were 0.8 mSv/month and 0.66 mGy/month, respectively. The leaded glasses reduced the exposure by ~60%. Even if the surgeons are exposed to the maximum dose of X-ray radiation for 5 years, the equivalent doses to the eye lens will not exceed the present limit recommended by the ICRP.

  17. Tonic cervical influences on eye nystagmus following hemilabyrinthectomy: immediate and plastic effects.

    PubMed

    Pettorossi, V E; Petrosini, L

    1984-12-17

    In intact guinea pigs a passive horizontal rotation of the body about the fixed head induces compensatory ocular movements (cervico-ocular reflex). When the static neck deviation is maintained, a significant ocular displacement is observed. In acutely hemilabyrinthectomized animals, static body deviation towards the lesion side tonically alters eye nystagmus. It affects slow phase eye velocity and quick phase amplitude and frequency causing the eye to reach a less eccentric orbital position. Apart from such immediate influences, a plastic effect on eye nystagmus abatement is induced. In the animals restrained with no body-on-head deviation, abatement of nystagmus is delayed with respect to the animals restrained with 35 degrees body deviation towards the lesion side. Thus the head position signal is not only a contributing factor for the correction of postural deficits but also influences the time course of the ocular balancing process following unilateral vestibular damage.

  18. Magnetic eye tracking in mice

    PubMed Central

    Payne, Hannah L

    2017-01-01

    Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of <0.1°. Magnetic eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications. PMID:28872455

  19. Does conspicuity enhance distraction? Saliency and eye landing position when searching for objects.

    PubMed

    Foulsham, Tom; Underwood, Geoffrey

    2009-06-01

    While visual saliency may sometimes capture attention, the guidance of eye movements in search is often dominated by knowledge of the target. How is the search for an object influenced by the saliency of an adjacent distractor? Participants searched for a target amongst an array of objects, with distractor saliency having an effect on response time and on the speed at which targets were found. Saliency did not predict the order in which objects in target-absent trials were fixated. The within-target landing position was distributed around a modal position close to the centre of the object. Saliency did not affect this position, the latency of the initial saccade, or the likelihood of the distractor being fixated, suggesting that saliency affects the allocation of covert attention and not just eye movements.

  20. Internal structure changes of eyelash induced by eye makeup.

    PubMed

    Fukami, Ken-Ichi; Inoue, Takafumi; Kawai, Tomomitsu; Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio

    2014-01-01

    To investigate how eye makeup affects eyelash structure, internal structure of eyelashes were observed with a scanning X-ray microscopic tomography system using synchrotron radiation light source. Eyelash samples were obtained from 36 Japanese women aged 20-70 years and whose use of eye makeup differed. Reconstructed cross-sectional images showed that the structure of the eyelash closely resembled that of scalp hair. The eyelash structure is changed by use of eye makeup. There was a positive correlation between the frequency of mascara use and the degree of cracking in cuticle. The positive correlation was also found between the frequency of mascara use and the porosity of the cortex. By contrast, the use of eyelash curler did not affect the eyelash structure with statistical significance.

  1. Descemet Stripping Automated Endothelial Keratoplasty for Failed Penetrating Keratoplasty: Influence of the Graft-Host Junction on the Graft Survival Rate.

    PubMed

    Omoto, Takashi; Sakisaka, Toshihiro; Toyono, Tetsuya; Yoshida, Junko; Shirakawa, Rika; Miyai, Takashi; Yamagami, Satoru; Usui, Tomohiko

    2018-04-01

    To investigate the clinical results of Descemet stripping automated endothelial keratoplasty (DSAEK) for failed penetrating keratoplasty (PK) and the influence of the graft-host junction (GHJ) on the graft survival rate. Data were retrospectively collected on patient demographics, visual outcomes, complications, and graft survival rate for 17 eyes of 16 patients who underwent DSAEK for failed PK. The graft survival rate was compared between the eyes when divided into a bump group and a well-aligned group according to the shape of the GHJ detected on anterior segment optical coherence tomography. The most common indication for initial PK was bullous keratopathy after glaucoma surgery (35.3%). Seven eyes (41.2%) were classified into the bump group and 10 eyes (58.8%) into the well-aligned group. The mean best-ever documented visual acuity (BDVA) after DSAEK was 0.33 logMAR. Postoperatively, almost 70% of eyes achieved a BDVA that was within 0.2 logMAR of their preoperative BDVA. Graft detachment occurred in 29.4% of eyes and primary graft failure in 17.6%. All primary failures occurred in the bump group. The cumulative graft survival rate was 82.3% at 1 year, 73.2% at 2 years, and 58.6% at 3 years. Graft failure was more likely in eyes in the bump group than in those in the well-aligned group (P = 0.037, Wilcoxon test). DSAEK for failed PK had a favorable outcome in this study. However, the GHJ should be assessed carefully before performing the procedure.

  2. Management of bull’s-eye rot of apple using pre- and postharvest fungicides

    USDA-ARS?s Scientific Manuscript database

    Bull’s-eye rot caused by Cryptosporiopsis kienholzii, Neofabraea alba, N. malicorticis and N. perennans is a common postharvest disease of apple and pear in the US Pacific Northwest. Fruit infection by these causal fungi occurs in the orchard and is latent at harvest. A primary practice for control ...

  3. Performing pediatric eye exams in primary care.

    PubMed

    Martin, Elaine F

    2017-08-17

    Early vision care is critical for all children. If undetected, eye disorders such as amblyopia and strabismus may result in permanent vision loss. Vision exams should include a careful history and physical including fix and follow, red reflex, and cover/uncover testing. Photo screening and visual acuity exams should be administered whenever possible.

  4. Loss of Neurofilament Labeling in the Primary Visual Cortex of Monocularly Deprived Monkeys

    PubMed Central

    Duffy, Kevin R.; Livingstone, Margaret S.

    2009-01-01

    Visual experience during early life is important for the development of neural organizations that support visual function. Closing one eye (monocular deprivation) during this sensitive period can cause a reorganization of neural connections within the visual system that leaves the deprived eye functionally disconnected. We have assessed the pattern of neurofilament labeling in monocularly deprived macaque monkeys to examine the possibility that a cytoskeleton change contributes to deprivation-induced reorganization of neural connections within the primary visual cortex (V-1). Monocular deprivation for three months starting around the time of birth caused a significant loss of neurofilament labeling within deprived-eye ocular dominance columns. Three months of monocular deprivation initiated in adulthood did not produce a loss of neurofilament labeling. The evidence that neurofilament loss was found only when deprivation occurred during the sensitive period supports the notion that the loss permits restructuring of deprived-eye neural connections within the visual system. These results provide evidence that, in addition to reorganization of LGN inputs, the intrinsic circuitry of V-1 neurons is altered when monocular deprivation occurs early in development. PMID:15563721

  5. How physician electronic health record screen sharing affects patient and doctor non-verbal communication in primary care.

    PubMed

    Asan, Onur; Young, Henry N; Chewning, Betty; Montague, Enid

    2015-03-01

    Use of electronic health records (EHRs) in primary-care exam rooms changes the dynamics of patient-physician interaction. This study examines and compares doctor-patient non-verbal communication (eye-gaze patterns) during primary care encounters for three different screen/information sharing groups: (1) active information sharing, (2) passive information sharing, and (3) technology withdrawal. Researchers video recorded 100 primary-care visits and coded the direction and duration of doctor and patient gaze. Descriptive statistics compared the length of gaze patterns as a percentage of visit length. Lag sequential analysis determined whether physician eye-gaze influenced patient eye gaze, and vice versa, and examined variations across groups. Significant differences were found in duration of gaze across groups. Lag sequential analysis found significant associations between several gaze patterns. Some, such as DGP-PGD ("doctor gaze patient" followed by "patient gaze doctor") were significant for all groups. Others, such DGT-PGU ("doctor gaze technology" followed by "patient gaze unknown") were unique to one group. Some technology use styles (active information sharing) seem to create more patient engagement, while others (passive information sharing) lead to patient disengagement. Doctors can engage patients in communication by using EHRs in the visits. EHR training and design should facilitate this. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. UVB-induced epidermal pigmentation in mice eyes with no contact lens wear and non-UVB blocking and UVB blocking contact lens wear.

    PubMed

    Hiramoto, Keiichi; Kobayashi, Hiromi; Yamate, Yurika; Ishii, Masamitsu; Sato, Takao; Inoue, Masayasu

    2013-02-01

    Irradiation by ultraviolet (UV) B is known to increase the number of Dopa-positive melanocytes in the skin. This study examines the effectiveness of a contact lens for the defense of UVB eye irradiation-induced pigmentation. A 2.5 kJ/m(2) dose of UVB radiation was delivered by a sunlamp to the eye of C57BL/6j male mice, and changes in the expression of Dopa-positive melanocytes in the epidermis and the plasma level of alpha-melanocyte-stimulating hormone (α-MSH) was analyzed. The degree of change in the Dopa-positive melanocytes expression was reduced by UVB blocking contact lens using mice given UVB irradiation to the eye. The plasma level of α-MSH increased in the C57BL/6j mice after irradiation to the eye, but there was no increase in the UVB blocking contact lens mice given UVB irradiation to the eye. Both the increase of the expression of Dopa-positive melanocytes and the plasma level of α-MSH were strongly suppressed by an alignment fitting UVB blocking contact lens and only a slightly suspended UVB blocking contact lens. In addition, these changes were successfully inhibited by a UVB blocking contact lens but not by a non-UVB blocking contact lens with a similar absorbance. These observations suggest that the UVB blocking contact lens inhibits the pigmentation of the epidermis in mice by suppressing of the α-MSH. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Prevalence of correctable visual impairment in primary school children in Qassim Province, Saudi Arabia.

    PubMed

    Aldebasi, Yousef H

    2014-01-01

    The worldwide prevalence of refractive errors (RE), which is a common cause of treatable visual impairment among children, varies widely. We assessed the prevalence of correctable visual impairment (uncorrected RE) in primary school children in Qassim, Saudi Arabia. A cross-sectional study was conducted in 21 primary schools. A total of 5176 children (mean age 9.5±1.8 years), 2573 boys (49.7%) and 2603 girls (50.3%), underwent a comprehensive eye examination. The examinations consisted of visual acuity, autorefraction, cover test, ocular motility, pupillary evaluation, anterior segment examination, cycloplegic auto-refraction and dilated fundus examination with direct ophthalmoscopy. The children were divided into groups based on their age and gender. The overall prevalence of RE in the better eye was 18.6% (n=963), and the prevalence of uncorrected RE 16.3% (n=846), with only 2.3% (n=127) of children wearing spectacles during examination. The prevalence of uncorrected myopia (5.8%) and myopic astigmatism (5.4%) was higher compared to that of hyperopic astigmatism (2.7%), mixed astigmatism (1.7%) and hyperopia (0.7%). The anisometropia prevalence was 3.6%. Risks for astigmatism, myopia and anisometropia were positively associated with age. In addition, myopia and anisometropia risks were also associated with female gender, while risk of astigmatism was correlated with male gender. Few children with vision reducing RE wore spectacles; an additional 16.3% of children could benefit from spectacle prescription. The prevalence of uncorrected RE in children is relatively high and represents an important public health problem in school-aged children in Qassim province. Performance of routine periodical vision screening throughout childhood may reverse this situation. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  8. Three-dimensional organization of vestibular-related eye movements to off-vertical axis rotation and linear translation in pigeons

    NASA Technical Reports Server (NTRS)

    Dickman, J. D.; Angelaki, D. E.

    1999-01-01

    During linear accelerations, compensatory reflexes should continually occur in order to maintain objects of visual interest as stable images on the retina. In the present study, the three-dimensional organization of the vestibulo-ocular reflex in pigeons was quantitatively examined during linear accelerations produced by constant velocity off-vertical axis yaw rotations and translational motion in darkness. With off-vertical axis rotations, sinusoidally modulated eye-position and velocity responses were observed in all three components, with the vertical and torsional eye movements predominating the response. Peak torsional and vertical eye positions occurred when the head was oriented with the lateral visual axis of the right eye directed orthogonal to or aligned with the gravity vector, respectively. No steady-state horizontal nystagmus was obtained with any of the rotational velocities (8-58 degrees /s) tested. During translational motion, delivered along or perpendicular to the lateral visual axis, vertical and torsional eye movements were elicited. No significant horizontal eye movements were observed during lateral translation at frequencies up to 3 Hz. These responses suggest that, in pigeons, all linear accelerations generate eye movements that are compensatory to the direction of actual or perceived tilt of the head relative to gravity. In contrast, no translational horizontal eye movements, which are known to be compensatory to lateral translational motion in primates, were observed under the present experimental conditions.

  9. A generalised porous medium approach to study thermo-fluid dynamics in human eyes.

    PubMed

    Mauro, Alessandro; Massarotti, Nicola; Salahudeen, Mohamed; Romano, Mario R; Romano, Vito; Nithiarasu, Perumal

    2018-03-22

    The present work describes the application of the generalised porous medium model to study heat and fluid flow in healthy and glaucomatous eyes of different subject specimens, considering the presence of ocular cavities and porous tissues. The 2D computational model, implemented into the open-source software OpenFOAM, has been verified against benchmark data for mixed convection in domains partially filled with a porous medium. The verified model has been employed to simulate the thermo-fluid dynamic phenomena occurring in the anterior section of four patient-specific human eyes, considering the presence of anterior chamber (AC), trabecular meshwork (TM), Schlemm's canal (SC), and collector channels (CC). The computational domains of the eye are extracted from tomographic images. The dependence of TM porosity and permeability on intraocular pressure (IOP) has been analysed in detail, and the differences between healthy and glaucomatous eye conditions have been highlighted, proving that the different physiological conditions of patients have a significant influence on the thermo-fluid dynamic phenomena. The influence of different eye positions (supine and standing) on thermo-fluid dynamic variables has been also investigated: results are presented in terms of velocity, pressure, temperature, friction coefficient and local Nusselt number. The results clearly indicate that porosity and permeability of TM are two important parameters that affect eye pressure distribution. Graphical abstract Velocity contours and vectors for healthy eyes (top) and glaucomatous eyes (bottom) for standing position.

  10. Transposed-Letter Effects in Reading: Evidence from Eye Movements and Parafoveal Preview

    ERIC Educational Resources Information Center

    Johnson, Rebecca L.; Perea, Manuel; Rayner, Keith

    2007-01-01

    Three eye movement experiments were conducted to examine the role of letter identity and letter position during reading. Before fixating on a target word within each sentence, readers were provided with a parafoveal preview that differed in the amount of useful letter identity and letter position information it provided. In Experiments 1 and 2,…

  11. Further improvement of an intraocular lens holder for more physiological measurements within a mechanical eye model

    NASA Astrophysics Data System (ADS)

    Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas

    2017-04-01

    To evaluate the performance of intraocular lenses to treat cataract, an optomechanical eye model was developed. One of the most crucial components is the IOL holder, which should guarantee a physiological representation of the capsular bag and a stable position during measurement sequences. Individual holders are required due to the fact that every IOL has different geometric parameters. A method which allows obtaining the correct dimensions for the holder of a special IOL was developed and tested, by verifying the position of the IOL before and after a measurement sequence. Results of telecentric measurements and MTF measurements show that the IOL position does not change during the displacement sequence induced by the stepper motors of the eye model.

  12. Computation of temperature elevation in rabbit eye irradiated by 2.45-GHz microwaves with different field configurations.

    PubMed

    Hirata, Akimasa; Watanabe, Soichi; Taki, Masao; Fujiwara, Osamu; Kojima, Masami; Sasaki, Kazuyuki

    2008-02-01

    This study calculated the temperature elevation in the rabbit eye caused by 2.45-GHz near-field exposure systems. First, we calculated specific absorption rate distributions in the eye for different antennas and then compared them with those observed in previous studies. Next, we re-examined the temperature elevation in the rabbit eye due to a horizontally-polarized dipole antenna with a C-shaped director, which was used in a previous study. For our computational results, we found that decisive factors of the SAR distribution in the rabbit eye were the polarization of the electromagnetic wave and antenna aperture. Next, we quantified the eye average specific absorption rate as 67 W kg(-1) for the dipole antenna with an input power density at the eye surface of 150 mW cm(-2), which was specified in the previous work as the minimum cataractogenic power density. The effect of administrating anesthesia on the temperature elevation was 30% or so in the above case. Additionally, the position where maximum temperature in the lens appears is discussed due to different 2.45-GHz microwave systems. That position was found to appear around the posterior of the lens regardless of the exposure condition, which indicates that the original temperature distribution in the eye was the dominant factor.

  13. Image-based computer-assisted diagnosis system for benign paroxysmal positional vertigo

    NASA Astrophysics Data System (ADS)

    Kohigashi, Satoru; Nakamae, Koji; Fujioka, Hiromu

    2005-04-01

    We develop the image based computer assisted diagnosis system for benign paroxysmal positional vertigo (BPPV) that consists of the balance control system simulator, the 3D eye movement simulator, and the extraction method of nystagmus response directly from an eye movement image sequence. In the system, the causes and conditions of BPPV are estimated by searching the database for record matching with the nystagmus response for the observed eye image sequence of the patient with BPPV. The database includes the nystagmus responses for simulated eye movement sequences. The eye movement velocity is obtained by using the balance control system simulator that allows us to simulate BPPV under various conditions such as canalithiasis, cupulolithiasis, number of otoconia, otoconium size, and so on. Then the eye movement image sequence is displayed on the CRT by the 3D eye movement simulator. The nystagmus responses are extracted from the image sequence by the proposed method and are stored in the database. In order to enhance the diagnosis accuracy, the nystagmus response for a newly simulated sequence is matched with that for the observed sequence. From the matched simulation conditions, the causes and conditions of BPPV are estimated. We apply our image based computer assisted diagnosis system to two real eye movement image sequences for patients with BPPV to show its validity.

  14. Early Experience with Technology-Based Eye Care Services (TECS): A Novel Ophthalmologic Telemedicine Initiative.

    PubMed

    Maa, April Y; Wojciechowski, Barbara; Hunt, Kelly J; Dismuke, Clara; Shyu, Jason; Janjua, Rabeea; Lu, Xiaoqin; Medert, Charles M; Lynch, Mary G

    2017-04-01

    The aging population is at risk of common eye diseases, and routine eye examinations are recommended to prevent visual impairment. Unfortunately, patients are less likely to seek care as they age, which may be the result of significant travel and time burdens associated with going to an eye clinic in person. A new method of eye-care delivery that mitigates distance barriers and improves access was developed to improve screening for potentially blinding conditions. We present the quality data from the early experience (first 13 months) of Technology-Based Eye Care Services (TECS), a novel ophthalmologic telemedicine program. With TECS, a trained ophthalmology technician is stationed in a primary care clinic away from the main hospital. The ophthalmology technician follows a detailed protocol that collects information about the patient's eyes. The information then is interpreted remotely. Patients with possible abnormal findings are scheduled for a face-to-face examination in the eye clinic. Any patient with no known ocular disease who desires a routine eye screening examination is eligible. Technology-Based Eye Care Services was established in 5 primary care clinics in Georgia surrounding the Atlanta Veterans Affairs hospital. Four program operation metrics (patient satisfaction, eyeglass remakes, disease detection, and visit length) and 2 access-to-care metrics (appointment wait time and no-show rate) were tracked. Care was rendered to 2690 patients over the first 13 months of TECS. The program has been met with high patient satisfaction (4.95 of 5). Eyeglass remake rate was 0.59%. Abnormal findings were noted in 36.8% of patients and there was >90% agreement between the TECS reading and the face-to-face findings of the physician. TECS saved both patient (25% less) and physician time (50% less), and access to care substantially improved with 99% of patients seen within 14 days of contacting the eye clinic, with a TECS no-show rate of 5.2%. The early experience with TECS has been promising. Tele-ophthalmology has the potential to improve operational efficiency, reduce cost, and significantly improve access to care. Although further study is necessary, TECS shows potential to help prevent avoidable vision loss. Published by Elsevier Inc.

  15. Vitrectomy outcomes in eyes with diabetic macular edema and vitreomacular traction.

    PubMed

    Haller, Julia A; Qin, Haijing; Apte, Rajendra S; Beck, Roy R; Bressler, Neil M; Browning, David J; Danis, Ronald P; Glassman, Adam R; Googe, Joseph M; Kollman, Craig; Lauer, Andreas K; Peters, Mark A; Stockman, Margaret E

    2010-06-01

    To evaluate vitrectomy for diabetic macular edema (DME) in eyes with at least moderate vision loss and vitreomacular traction. Prospective cohort study. The primary cohort included 87 eyes with DME and vitreomacular traction based on investigator's evaluation, visual acuity 20/63-20/400, optical coherence tomography (OCT) central subfield >300 microns and no concomitant cataract extraction at the time of vitrectomy. Surgery was performed according to the investigator's usual routine. Follow-up visits were performed after 3 months, 6 months (primary end point), and 1 year. Visual acuity, OCT retinal thickening, and operative complications. At baseline, median visual acuity in the 87 eyes was 20/100 and median OCT thickness was 491 microns. During vitrectomy, additional procedures included epiretinal membrane peeling in 61%, internal limiting membrane peeling in 54%, panretinal photocoagulation in 40%, and injection of corticosteroids at the close of the procedure in 64%. At 6 months, median OCT central subfield thickness decreased by 160 microns, with 43% having central subfield thickness <250 microns and 68% having at least a 50% reduction in thickening. Visual acuity improved by > or =10 letters in 38% (95% confidence interval, 28%-49%) and deteriorated by > or =10 letters in 22% (95% confidence interval, 13%-31%). Postoperative complications through 6 months included vitreous hemorrhage (5 eyes), elevated intraocular pressure requiring treatment (7 eyes), retinal detachment (3 eyes), and endophthalmitis (1 eye). Few changes in results were noted between 6 months and 1 year. After vitrectomy performed for DME and vitreomacular traction, retinal thickening was reduced in most eyes. Between 28% and 49% of eyes with characteristics similar to those included in this study are likely to have improvement of visual acuity, whereas between 13% and 31% are likely to have worsening. The operative complication rate is low and similar to what has been reported for this procedure. These data provide estimates of surgical outcomes and serve as a reference for future studies that might consider vitrectomy for DME in eyes with at least moderate vision loss and vitreomacular traction. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Computer use in primary care and patient-physician communication.

    PubMed

    Sobral, Dilermando; Rosenbaum, Marcy; Figueiredo-Braga, Margarida

    2015-07-08

    This study evaluated how physicians and patients perceive the impact of computer use on clinical communication, and how a patient-centered orientation can influence this impact. The study followed a descriptive cross-sectional design and included 106 family physicians and 392 patients. An original questionnaire assessed computer use, participants' perspective of its impact, and patient centered strategies. Physicians reported spending 42% of consultation time in contact with the computer. A negative impact of computer in patient-physician communication regarding the consultation length, confidentiality, maintaining eye contact, active listening to the patient, and ability to understand the patient was reported by physicians, while patients reported a positive effect for all the items. Physicians considered that the usual computer placement in their consultation room was significantly unfavorable to patient-physician communication. Physicians perceive the impact of computer use on patient-physician communication as negative, while patients have a positive perception of computer use on patient-physician communication. Consultation support can represent a challenge to physicians who recognize its negative impact in patient centered orientation. Medical education programs aiming to enhance specific communication skills and to better integrate computer use in primary care settings are needed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Dual interferometer for dynamic measurement of corneal topography

    NASA Astrophysics Data System (ADS)

    Micali, Jason D.; Greivenkamp, John E.

    2016-08-01

    The cornea is the anterior most surface of the eye and plays a critical role in vision. A thin fluid layer, the tear film, coats the outer surface of the cornea and serves to protect, nourish, and lubricate the cornea. At the same time, the tear film is responsible for creating a smooth continuous surface, where the majority of refraction takes place in the eye. A significant component of vision quality is determined by the shape of the cornea and stability of the tear film. A dual interferometer system for measuring the dynamic corneal topography is designed, built, verified, and qualified by testing on human subjects. The system consists of two coaligned simultaneous phase-shifting polarization-splitting Twyman-Green interferometers. The primary interferometer measures the surface of the tear film while the secondary interferometer tracks the absolute position of the cornea, which provides enough information to reconstruct the absolute shape of the cornea. The results are high-resolution and high-accuracy surface topography measurements of the in vivo tear film and cornea that are captured at standard camera frame rates.

  18. Measurement of ocular aberrations in downward gaze using a modified clinical aberrometer

    PubMed Central

    Ghosh, Atanu; Collins, Michael J; Read, Scott A; Davis, Brett A; Iskander, D. Robert

    2011-01-01

    Changes in corneal optics have been measured after downward gaze. However, ocular aberrations during downward gaze have not been previously measured. A commercial Shack-Hartmann aberrometer (COAS-HD) was modified by adding a relay lens system and a rotatable beam splitter to allow on-axis aberration measurements in primary gaze and downward gaze with binocular fixation. Measurements with the modified aberrometer (COAS-HD relay system) in primary and downward gaze were validated against a conventional aberrometer. In human eyes, there were significant changes (p<0.05) in defocus C(2,0), primary astigmatism C(2,2) and vertical coma C(3,−1) in downward gaze (25 degrees) compared to primary gaze, indicating the potential influence of biomechanical forces on the optics of the eye in downward gaze. To demonstrate a further clinical application of this modified aberrometer, we measured ocular aberrations when wearing a progressive addition lens (PAL) in primary gaze (0 degree), 15 degrees downward gaze and 25 degrees downward gaze. PMID:21412451

  19. Optimal Eye-Gaze Fixation Position for Face-Related Neural Responses

    PubMed Central

    Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina

    2013-01-01

    It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template. PMID:23762224

  20. Optimal eye-gaze fixation position for face-related neural responses.

    PubMed

    Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina

    2013-01-01

    It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template.

  1. Eye-hand coupling during closed-loop drawing: evidence of shared motor planning?

    PubMed

    Reina, G Anthony; Schwartz, Andrew B

    2003-04-01

    Previous paradigms have used reaching movements to study coupling of eye-hand kinematics. In the present study, we investigated eye-hand kinematics as curved trajectories were drawn at normal speeds. Eye and hand movements were tracked as a monkey traced ellipses and circles with the hand in free space while viewing the hand's position on a computer monitor. The results demonstrate that the movement of the hand was smooth and obeyed the 2/3 power law. Eye position, however, was restricted to 2-3 clusters along the hand's trajectory and fixed approximately 80% of the time in one of these clusters. The eye remained stationary as the hand moved away from the fixation for up to 200 ms and saccaded ahead of the hand position to the next fixation along the trajectory. The movement from one fixation cluster to another consistently occurred just after the tangential hand velocity had reached a local minimum, but before the next segment of the hand's trajectory began. The next fixation point was close to an area of high curvature along the hand's trajectory even though the hand had not reached that point along the path. A visuo-motor illusion of hand movement demonstrated that the eye movement was influenced by hand movement and not simply by visual input. During the task, neural activity of pre-motor cortex (area F4) was recorded using extracellular electrodes and used to construct a population vector of the hand's trajectory. The results suggest that the saccade onset is correlated in time with maximum curvature in the population vector trajectory for the hand movement. We hypothesize that eye and arm movements may have common, or shared, information in forming their motor plans.

  2. Morphology, topography, and optics of the orthokeratology cornea

    NASA Astrophysics Data System (ADS)

    Faria-Ribeiro, Miguel; Belsue, Rafael Navarro; López-Gil, Norberto; González-Méijome, José Manuel

    2016-07-01

    The goal of this work was to objectively characterize the external morphology, topography, and optics of the cornea after orthokeratology (ortho-k). A number of 24 patients between the ages of 17 and 30 years (median=24 years) were fitted with Corneal Refractive Therapy® contact lenses to correct myopia between -2.00 and -5.00 diopters (D) (median=-3.41 D). A classification algorithm was applied to conduct an automatic segmentation based on the mean local curvature. As a result, three zones (optical zone, transition zone, and peripheral zone) were delimited. Topographical analysis was provided through global and zonal fit to a general ellipsoid. Ray trace on partially customized eye models provided wave aberrations and retinal image quality. Monozone topographic description of the ortho-k cornea loses accuracy when compared with zonal description. Primary (C40) and secondary (C60) spherical aberration (SA) coefficients for a 5-mm pupil increased 3.68 and 19 times, respectively, after the treatments. The OZ area showed a strong correlation with C40 (r=-0.49, p<0.05) and a very strong correlation with C60 (r=0.78, p<0.01). The OZ, as well as the TZ, areas did not correlate with baseline refraction. The increase in the eye's positive SA after ortho-k is the major factor responsible for the decreased retinal optical quality of the unaccommodated eye.

  3. Eye-movements intervening between two successive sounds disrupt comparisons of auditory location

    PubMed Central

    Pavani, Francesco; Husain, Masud; Driver, Jon

    2008-01-01

    Summary Many studies have investigated how saccades may affect the internal representation of visual locations across eye-movements. Here we studied instead whether eye-movements can affect auditory spatial cognition. In two experiments, participants judged the relative azimuth (same/different) of two successive sounds presented from a horizontal array of loudspeakers, separated by a 2.5 secs delay. Eye-position was either held constant throughout the trial (being directed in a fixed manner to the far left or right of the loudspeaker array), or had to be shifted to the opposite side of the array during the retention delay between the two sounds, after the first sound but before the second. Loudspeakers were either visible (Experiment1) or occluded from sight (Experiment 2). In both cases, shifting eye-position during the silent delay-period affected auditory performance in the successive auditory comparison task, even though the auditory inputs to be judged were equivalent. Sensitivity (d′) for the auditory discrimination was disrupted, specifically when the second sound shifted in the opposite direction to the intervening eye-movement with respect to the first sound. These results indicate that eye-movements affect internal representation of auditory location. PMID:18566808

  4. Eye-movements intervening between two successive sounds disrupt comparisons of auditory location.

    PubMed

    Pavani, Francesco; Husain, Masud; Driver, Jon

    2008-08-01

    Many studies have investigated how saccades may affect the internal representation of visual locations across eye-movements. Here, we studied, instead, whether eye-movements can affect auditory spatial cognition. In two experiments, participants judged the relative azimuth (same/different) of two successive sounds presented from a horizontal array of loudspeakers, separated by a 2.5-s delay. Eye-position was either held constant throughout the trial (being directed in a fixed manner to the far left or right of the loudspeaker array) or had to be shifted to the opposite side of the array during the retention delay between the two sounds, after the first sound but before the second. Loudspeakers were either visible (Experiment 1) or occluded from sight (Experiment 2). In both cases, shifting eye-position during the silent delay-period affected auditory performance in thn the successive auditory comparison task, even though the auditory inputs to be judged were equivalent. Sensitivity (d') for the auditory discrimination was disrupted, specifically when the second sound shifted in the opposite direction to the intervening eye-movement with respect to the first sound. These results indicate that eye-movements affect internal representation of auditory location.

  5. Otolith-Canal Convergence In Vestibular Nuclei Neurons

    NASA Technical Reports Server (NTRS)

    Dickman, J. David; Si, Xiao-Hong

    2002-01-01

    The current final report covers the period from June 1, 1999 to May 31, 2002. The primary objective of the investigation was to determine how information regarding head movements and head position relative to gravity is received and processed by central vestibular nuclei neurons in the brainstem. Specialized receptors in the vestibular labyrinths of the inner ear function to detect angular and linear accelerations of the head, with receptors located in the semicircular canals transducing rotational head movements and receptors located in the otolith organs transducing changes in head position relative to gravity or linear accelerations of the head. The information from these different receptors is then transmitted to central vestibular nuclei neurons which process the input signals, then project the appropriate output information to the eye, head, and body musculature motor neurons to control compensatory reflexes. Although a number of studies have reported on the responsiveness of vestibular nuclei neurons, it has not yet been possible to determine precisely how these cells combine the information from the different angular and linear acceleration receptors into a correct neural output signal. In the present project, rotational and linear motion stimuli were separately delivered while recording responses from vestibular nuclei neurons that were characterized according to direct input from the labyrinth and eye movement sensitivity. Responses from neurons receiving convergent input from the semicircular canals and otolith organs were quantified and compared to non-convergent neurons.

  6. Superselective intra-arterial chemotherapy in the primary management of advanced intra-ocular retinoblastoma: first 4-year experience from a single institution in Turkey.

    PubMed

    Tuncer, Samuray; Sencer, Serra; Kebudi, Rejin; Tanyıldız, Burak; Cebeci, Zafer; Aydın, Kubilay

    2016-11-01

    To report our 4-year experience in Turkey, with advanced intra-ocular retinoblastoma managed primarily with intra-arterial chemotherapy (IAC). From October 2011 to September 2015, 26 group D eyes of 24 treatment-naïve retinoblastoma patients managed primarily with IAC were evaluated in this prospective study. Of 76 procedures, ophthalmic artery cannulation failed in two patients with unilateral involvement. In the remaining 22 patients (24 eyes), the mean age at diagnosis was 18 months (range, 6-55 months). Each eye received a mean of 3 IAC sessions/eye (range, 2-5 sessions). After a median follow-up of 29 months (range, 6-55 months), complete regression of the main tumour was achieved in 23 of 24 eyes. One eye with partial regression required enucleation due to ciliary body involvement by the tumour. Overall, 16 eyes (66.6%) were salvaged with primary IAC with or without additional local treatments, and eight (33.3%) required enucleation. The main IAC-related periocular complications included transient eyelid oedema (n = 13), ptosis (n = 6) and forehead hyperpigmentation (n = 3), each resolving in 2 weeks to 4 months. Intra-ocular complications included chorioretinal atrophy (n = 9), newly noted retinal detachment (n = 5) and vitreous haemorrhage (n = 1). Kaplan-Meier eye estimates of enucleation-free survival rates were 83.3% (95% CI, 68.4-98.1%), 69.1% (95% CI, 49.8-88.3%) and 62.9 (95% CI, 41.9-83.8%) at 6 months, 1 and 2 years, respectively, and stable thereafter. Our first 4-year experience in Turkey showed that enucleation or external-beam radiotherapy could be avoided in two-thirds of eyes with advanced intra-ocular retinoblastoma managed primarily with IAC. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Prognostic value of gonioscopy after deep sclerectomy.

    PubMed

    Moreno-Montañés, J; Rebolleda, G; Muñoz-Negrete, F J

    2007-01-01

    To ascertain gonioscopic characteristics and identify prognostic indicators related to intraocular pressure (IOP) after deep sclerectomy (DS). A transversal, prospective, and nonselected study was performed in 106 eyes (95 patients) after DS. Three surgeons performed all the surgeries and the gonioscopic examination, using the same protocol including 13 gonioscopic data. These data were evaluated for an association with postoperative IOP and time after surgery. A subscleral space was found in 91 eyes (85.8%), with visualization of the line of scleral flap in 48 eyes (45.3%). The trabeculo-Descemet membrane (TDM) was transparent in 46 eyes (43.4%), opaque in 4 cases, and pigmented in 18 eyes. This TDM was broken using Nd:YAG laser goniopuncture in 38 eyes(35.8%). Thin vessels around TDM were found in 58 eyes (54.7%), and blood remained in 25 eyes (23.5%). Gonioscopic variables significantly positively related with postoperative IOP were as follows: presence of subscleral space, scleral flap line view, and a Schwalbe line depressed. A narrow anterior chamber angle and iris synechia in TDM had a statistically significant negative effect on the postoperative IOP control. Similarly, eyes requiring Nd:YAG goniopuncture had a worse IOP control. The frequency of eyes with visible subscleral space and transparent TDM decreases with time after surgery (p=0.001). A visible subscleral space was a gonioscopic sign positively related to IOP control after surgery, although it decreased with follow-up. Eyes with goniopuncture, postoperative narrow angle, and iris synechia had worse postoperative IOP control. Although new vessels in TDM were a common finding after DS, the authors did not find any association with postoperative IOP.

  8. Does mood influence text processing and comprehension? Evidence from an eye-movement study.

    PubMed

    Scrimin, Sara; Mason, Lucia

    2015-09-01

    Previous research has indicated that mood influences cognitive processes. However, there is scarce data regarding the link between everyday emotional states and readers' text processing and comprehension. We aim to extend current research on the effects of mood induction on science text processing and comprehension, using eye-tracking methodology. We investigated whether a positive-, negative-, and neutral-induced mood influences online processing, as revealed by indices of visual behaviour during reading, and offline text comprehension, as revealed by post-test questions. We were also interested in the link between text processing and comprehension. Seventy-eight undergraduate students randomly assigned to three mood-induction conditions. Students were mood-induced by watching a video clip. They were then asked to read a scientific text while eye movements were registered. Pre- and post-reading knowledge was assessed through open-ended questions. Experimentally induced moods lead readers to process an expository text differently. Overall, students in a positive mood spent significantly longer on the text processing than students in the negative and neutral moods. Eye-movement patterns indicated more effective processing related to longer proportion of look-back fixation times in positive-induced compared with negative-induced readers. Students in a positive mood also comprehended the text better, learning more factual knowledge, compared with students in the negative group. Only for the positive-induced readers did the more purposeful second-pass reading positively predict text comprehension. New insights are given on the effects of normal mood variations and students' text processing and comprehension by the use of eye-tracking methodology. Important implications for the role of emotional states in educational settings are highlighted. © 2015 The British Psychological Society.

  9. MO-F-CAMPUS-I-04: Patient Eye-Lens Dose Reduction in Routine Brain CT Examinations Using Organ-Based Tube Current Modulation and In-Plane Bismuth Shielding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Hui-Yu; Liao, Ying-Lan; Chang Gung University / Chang Gung Memorial Hospital, Taoyun, Taiwan

    Purpose: The purpose of this study is to assess eye-lens dose for patients who underwent brain CT examinations using two dose reduction Methods: organ-based tube current modulation (OBTCM) and in-plane bismuth shielding method. Methods: This study received institutional review board approval; written informed consent to participate was obtained from all patients. Ninety patients who underwent the routine brain CT examination were randomly assigned to three groups, ie. routine, OBTCM, and bismuth shield. The OBTCM technique reduced the tube current when the X-ray tube rotates in front of patients’ eye-lens region. The patients in the bismuth shield group were covered one-plymore » bismuth shield in the eyes’ region. Eye-lens doses were measured using TLD-100H chips and the total effective doses were calculated using CT-Expo according to the CT scanning parameters. The surface doses for patients at off-center positions were assessed to evaluate the off-centering effect. Results: Phantom measurements indicates that OBTCM technique could reduced by 26% to 28% of the surface dose to the eye lens, and increased by 25% of the surface dose at the opposed incident direction at the angle of 180°. Patients’ eye-lens doses were reduced 16.9% and 30.5% dose of bismuth shield scan and OBTCM scan, respectively compared to the routine scan. The eye-lens doses were apparently increased when the table position was lower than isocenter. Conclusion: Reducing the dose to the radiosensitive organs, such as eye lens, during routine brain CT examinations could lower the radiation risks. The OBTCM technique and in-plane bismuth shielding could be used to reduce the eye-lens dose. The eye-lens dose could be effectively reduced using OBTCM scan without interfering the diagnostic image quality. Patient position relative the CT gantry also affects the dose level of the eye lens. This study was supported by the grants from the Ministry of Science and Technology of Taiwan (MOST103-2314-B-182-009-MY2), and Chang Gung Memorial Hospital (CMRPD1C0682)« less

  10. Patient acceptability of tear collection in the primary healthcare setting.

    PubMed

    Quah, Joanne Hui Min; Tong, Louis; Barbier, Sylvaine

    2014-04-01

    The primary healthcare setting is well placed for health screening. Tear fluid composition gives valuable information about the eye and systemic health, and there is now significant interest in the potential application of tears as a tool for health screening; however, the acceptability of tear collection in the primary healthcare setting as compared with other methods of human sample collection has not been previously addressed. The objective of this study was to evaluate the patient acceptability of tear collection in a primary healthcare setting. This was a cross-sectional study on 383 adult patients seeking primary healthcare, who were not diabetic and were not attending for an eye-related complaint. Tear collection was done using Schirmer strips, and an interviewer-administered questionnaire was conducted to collate information on the pain score (0-10) of the Schirmer tear collection, as well as to score the pain associated with their previous experience of antecubital venous puncture and finger prick test. The pain score for Schirmer tear collection was significantly lower (p < 0.001) than antecubital venous puncture but higher (p < 0.001) than finger prick. The pain scores for all three procedures were significantly higher in participants of younger age, female gender, and higher education level. Among the participants, 70% did not mind their tears being collected to screen for eye problems, whereas only 38% did not mind this procedure being performed for general health screening. Nevertheless, 69% of the participants preferred tear to urine collection, and 74% of participants preferred tear to blood collection. Tear collection using Schirmer strips is a highly acceptable form of investigation that has the potential for use in health screening in the primary healthcare setting. This study has implications on using tear collection as a method of ocular and systemic health screening in the primary healthcare setting.

  11. Using eye tracking technology to compare the effectiveness of malignant hyperthermia cognitive aid design.

    PubMed

    King, Roderick; Hanhan, Jaber; Harrison, T Kyle; Kou, Alex; Howard, Steven K; Borg, Lindsay K; Shum, Cynthia; Udani, Ankeet D; Mariano, Edward R

    2018-05-15

    Malignant hyperthermia is a rare but potentially fatal complication of anesthesia, and several different cognitive aids designed to facilitate a timely and accurate response to this crisis currently exist. Eye tracking technology can measure voluntary and involuntary eye movements, gaze fixation within an area of interest, and speed of visual response and has been used to a limited extent in anesthesiology. With eye tracking technology, we compared the accessibility of five malignant hyperthermia cognitive aids by collecting gaze data from twelve volunteer participants. Recordings were reviewed and annotated to measure the time required for participants to locate objects on the cognitive aid to provide an answer; cumulative time to answer was the primary outcome. For the primary outcome, there were differences detected between cumulative time to answer survival curves (P < 0.001). Participants demonstrated the shortest cumulative time to answer when viewing the Society for Pediatric Anesthesia (SPA) cognitive aid compared to four other publicly available cognitive aids for malignant hyperthermia, and this outcome was not influenced by the anesthesiologists' years of experience. This is the first study to utilize eye tracking technology in a comparative evaluation of cognitive aid design, and our experience suggests that there may be additional applications of eye tracking technology in healthcare and medical education. Potentially advantageous design features of the SPA cognitive aid include a single page, linear layout, and simple typescript with minimal use of single color blocking.

  12. The role of optometrists in India: An integral part of an eye health team

    PubMed Central

    De Souza, Neilsen; Cui, Yu; Looi, Stephanie; Paudel, Prakash; Shinde, Lakshmi; Kumar, Krishna; Berwal, Rajbir; Wadhwa, Rajesh; Daniel, Vinod; Flanagan, Judith; Holden, Brien

    2012-01-01

    India has a proud tradition of blindness prevention, being the first country in the world to implement a blindness control programme which focused on a model to address blinding eye disease. However, with 133 million people blind or vision impaired due to the lack of an eye examination and provision of an appropriate pair of spectacles, it is imperative to establish a cadre of eye care professionals to work in conjunction with ophthalmologists to deliver comprehensive eye care. The integration of highly educated four year trained optometrists into primary health services is a practical means of correcting refractive error and detecting ocular disease, enabling co-managed care between ophthalmologists and optometrists. At present, the training of optometrists varies from two year trained ophthalmic assistants/optometrists or refractionists to four year degree trained optometrists. The profession of optometry in India is not regulated, integrated into the health care system or recognised by the majority of people in India as provider of comprehensive eye care services. In the last two years, the profession of optometry in India is beginning to take the necessary steps to gain recognition and regulation to become an independent primary health care profession. The formation of the Indian Optometry Federation as the single peak body of optometry in India and the soon to be established Optometry Council of India are key organisations working towards the development and regulation of optometry. PMID:22944749

  13. Risk Factors Associated with Progression to Blindness from Primary Open-Angle Glaucoma in an African-American Population.

    PubMed

    Pleet, Alexander; Sulewski, Melanie; Salowe, Rebecca J; Fertig, Raymond; Salinas, Julia; Rhodes, Allison; Merritt Iii, William; Natesh, Vikas; Huang, Jiayan; Gudiseva, Harini V; Collins, David W; Chavali, Venkata Ramana Murthy; Tapino, Paul; Lehman, Amanda; Regina-Gigiliotti, Meredith; Miller-Ellis, Eydie; Sankar, Prithvi; Ying, Gui-Shuang; O'Brien, Joan M

    2016-08-01

    To determine the risk factors associated with progression to blindness from primary open-angle glaucoma (POAG) in an African-American population. This study examined 2119 patients enrolled in the Primary Open-Angle African-American Glaucoma Genetics (POAAGG) study. A total of 59 eyes were identified as legally blind as a result of POAG (cases) and were age-and sex-matched to 59 non-blind eyes with glaucoma (controls). Chart reviews were performed to record known and suspected risk factors. Cases were diagnosed with POAG at an earlier age than controls (p = 0.005). Of the 59 eyes of cases, 16 eyes (27.1%) presented with blindness at diagnosis. Cases had worse visual acuity (VA) at diagnosis (p < 0.0001), with VA worse than 20/40 conferring a 27 times higher risk of progression to blindness (p = 0.0005). Blind eyes also demonstrated more visual field defects (p = 0.01), higher pre-treatment intraocular pressure (IOP; p < 0.0001), and higher cup-to-disc ratio (p = 0.006) at diagnosis. IOP was less controlled in cases, and those with IOP ≥21 mmHg at more than 20% of follow-up visits were 73 times more likely to become blind (p < 0.0001). Cases missed a greater number of appointments per year (p = 0.003) and had non-adherence issues noted in their charts more often than controls (p = 0.03). However, other compliance data did not significantly differ between groups. Access to care, initial VA worse than 20/40, and poor control of IOP were the major risk factors associated with blindness from POAG. Future studies should examine earlier, more effective approaches to glaucoma screening as well as the role of genetics in these significantly younger patients who progress to blindness.

  14. Scanning electron microscopy of the trabecular meshwork: understanding the pathogenesis of primary angle closure glaucoma.

    PubMed

    Sihota, Ramanjit; Goyal, Amita; Kaur, Jasbir; Gupta, Viney; Nag, Tapas C

    2012-01-01

    To study ultrastructural changes of the trabecular meshwork in acute and chronic primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) eyes by scanning electron microscopy. Twenty-one trabecular meshwork surgical specimens from consecutive glaucomatous eyes after a trabeculectomy and five postmortem corneoscleral specimens were fixed immediately in Karnovsky solution. The tissues were washed in 0.1 M phosphate buffer saline, post-fixed in 1% osmium tetraoxide, dehydrated in acetone series (30-100%), dried and mounted. Normal trabecular tissue showed well-defined, thin, cylindrical uveal trabecular beams with many large spaces, overlying flatter corneoscleral beams and numerous smaller spaces. In acute PACG eyes, the trabecular meshwork showed grossly swollen, irregular trabecular endothelial cells with intercellular and occasional basal separation with few spaces. Numerous activated macrophages, leucocytes and amorphous debris were present. Chronic PACG eyes had a few, thickened posterior uveal trabecular beams visible. A homogenous deposit covered the anterior uveal trabeculae and spaces. Converging, fan-shaped trabecular beam configuration corresponded to gonioscopic areas of peripheral anterior synechiae. In POAG eyes, anterior uveal trabecular beams were thin and strap-like, while those posteriorly were wide, with a homogenous deposit covering and bridging intertrabecular spaces, especially posteriorly. Underlying corneoscleral trabecular layers and spaces were visualized in some areas. In acute PACG a marked edema of the endothelium probably contributes for the acute and marked intraocular pressure (IOP) elevation. Chronically raised IOP in chronic PACG and POAG probably results, at least in part, from decreased aqueous outflow secondary to widening and fusion of adjacent trabecular beams, together with the homogenous deposit enmeshing trabecular beams and spaces.

  15. Importance of Rapid Eye Movement Sleep Behavior Disorder to the Primary Care Physician.

    PubMed

    McCarter, Stuart J; Howell, Michael J

    2016-10-01

    Sleep disorders and neurodegenerative diseases are commonly encountered in primary care. A common, but underdiagnosed sleep disorder, rapid eye movement sleep behavior disorder (RBD), is highly associated with Parkinson disease and related disorders. Rapid eye movement sleep behavior disorder is common. It is estimated to affect 0.5% of the general population and more than 7% of individuals older than 60 years; however, most cases go unrecognized. Rapid eye movement sleep behavior disorder presents as dream enactment, often with patients thrashing, punching, and kicking while they are sleeping. Physicians can quickly assess for the presence of RBD with high sensitivity and specificity by asking patients the question "Have you ever been told that you act out your dreams, for example by punching or flailing your arms in the air or screaming and shouting in your sleep?" Patients with RBD exhibit subtle signs of neurodegenerative disease, such as mild motor slowing, constipation, or changes in sense of smell. These signs and symptoms may predict development of a neurodegenerative disease within 3 years. Ultimately, most patients with RBD develop a neurodegenerative disease, highlighting the importance of serial neurological examinations to assess for the presence of parkinsonism and/or cognitive impairment and prognostic counseling for these patients. Rapid eye movement sleep behavior disorder is treatable with melatonin (3-6 mg before bed) or clonazepam (0.5-1 mg before bed) and may be the most common, reversible cause of sleep-related injury. Thus, it is important to identify patients at risk of RBD in a primary care setting so that bedroom safety can be addressed and treatment may be initiated. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  16. Fetal eye movements on magnetic resonance imaging.

    PubMed

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3-45%. In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.

  17. Visual field recovery after vision restoration therapy (VRT) is independent of eye movements: an eye tracker study.

    PubMed

    Kasten, Erich; Bunzenthal, Ulrike; Sabel, Bernhard A

    2006-11-25

    It has been argued that patients with visual field defects compensate for their deficit by making more frequent eye movements toward the hemianopic field and that visual field enlargements found after vision restoration therapy (VRT) may be an artefact of such eye movements. In order to determine if this was correct, we recorded eye movements in hemianopic subjects before and after VRT. Visual fields were measured in subjects with homonymous visual field defects (n=15) caused by trauma, cerebral ischemia or haemorrhage (lesion age >6 months). Visual field charts were plotted using both high-resolution perimetry (HRP) and conventional perimetry before and after a 3-month period of VRT, with eye movements being recorded with a 2D-eye tracker. This permitted quantification of eye positions and measurements of deviation from fixation. VRT lead to significant visual field enlargements as indicated by an increase of stimulus detection of 3.8% when tested using HRP and about 2.2% (OD) and 3.5% (OS) fewer misses with conventional perimetry. Eye movements were expressed as the standard deviations (S.D.) of the eye position recordings from fixation. Before VRT, the S.D. was +/-0.82 degrees horizontally and +/-1.16 degrees vertically; after VRT, it was +/-0.68 degrees and +/-1.39 degrees , respectively. A cluster analysis of the horizontal eye movements before VRT showed three types of subjects with (i) small (n=7), (ii) medium (n=7) or (iii) large fixation instability (n=1). Saccades were directed equally to the right or the left side; i.e., with no preference toward the blind hemifield. After VRT, many subjects showed a smaller variability of horizontal eye movements. Before VRT, 81.6% of the recorded eye positions were found within a range of 1 degrees horizontally from fixation, whereas after VRT, 88.3% were within that range. In the 2 degrees range, we found 94.8% before and 98.9% after VRT. Subjects moved their eyes 5 degrees or more 0.3% of the time before VRT versus 0.1% after VRT. Thus, in this study, subjects with homonymous visual field defects who were attempting to fixate a central target while their fields were being plotted, typically showed brief horizontal shifts with no preference toward or away from the blind hemifield. These eye movements were usually less than 1 degrees from fixation. Large saccades toward the blind field after VRT were very rare. VRT has no effect on either the direction or the amplitude of horizontal eye movements during visual field testing. These results argue against the theory that the visual field enlargements are artefacts induced by eye movements.

  18. The Barrie Jones Lecture—Eye care for the neglected population: challenges and solutions

    PubMed Central

    Rao, G N

    2015-01-01

    Globally, pockets of ‘neglected populations' do not have access to basic health-care services and carry a much greater risk of blindness and visual impairment. While large-scale public health approaches to control blindness due to vitamin A deficiency, onchocerciasis, and trachoma are successful, other causes of blindness still take a heavy toll in the population. High-quality comprehensive eye care that is equitable is the approach that needs wide-scale application to alleviate this inequity. L V Prasad Eye Institute of India developed a multi-tier pyramidal model of eye care delivery that encompasses all levels from primary to advanced tertiary (quaternary). This has demonstrated the feasibility of ‘Universal Eye Health Coverage' covering promotive, preventive, corrective, and rehabilitative aspects of eye care. Using human resources with competency-based training, effective and cost-effective care could be provided to many disadvantaged people. PMID:25567375

  19. Optimizations and Applications in Head-Mounted Video-Based Eye Tracking

    ERIC Educational Resources Information Center

    Li, Feng

    2011-01-01

    Video-based eye tracking techniques have become increasingly attractive in many research fields, such as visual perception and human-computer interface design. The technique primarily relies on the positional difference between the center of the eye's pupil and the first-surface reflection at the cornea, the corneal reflection (CR). This…

  20. Visual Short-Term Memory During Smooth Pursuit Eye Movements

    ERIC Educational Resources Information Center

    Kerzel, Dirk; Ziegler, Nathalie E.

    2005-01-01

    Visual short-term memory (VSTM) was probed while observers performed smooth pursuit eye movements. Smooth pursuit keeps a moving object stabilized in the fovea. VSTM capacity for position was reduced during smooth pursuit compared with a condition with eye fixation. There was no difference between a condition in which the items were approximately…

  1. [Functional and Anatomic Outcomes of Primary and Secondary Internal Limiting Membrane Transplantation in Large and Persistent Macular Holes].

    PubMed

    Hess, Jelka A; Michels, Stephan; Becker, Matthias D

    2017-11-20

    Background The gold standard therapy for full-thickness macular holes (FTMH) is vitrectomy (PPV) with peeling of the internal limiting membrane (ILM), gas tamponade of the vitreous cavity and postoperative face-down positioning. Nevertheless, eyes with large macular holes (> 400 µm) and surgical failures remain difficult to manage. Recently, ILM transplantation (ILM-TX) techniques were developed with acceptable results, advocating different mechanisms of hole closure: in such a setting, the ILM could serve as a scaffold for neuronal tissue in the pedicle ILM flap technique or the ILM could induce a contraction of the FTMH rims through shrinking of a folded ILM plug. Patients/Material and Methods This retrospective study evaluates the functional and anatomic outcomes following ILM-TX for large FTMH and failed FMTH surgery. Large holes (group 1) were treated by the pedicle flap and the plug technique. Persistent holes following vitrectomy and ILM peeling (group 2) were treated with the plug technique. All ILM-TX were performed under perfluorocarbon liquid (PFCL) with a subsequent silicone oil tamponade. Results In group 1 (6 eyes), three eyes had a free ILM graft and three eyes underwent a pedunculated ILM-TX. The mean best corrected visual acuity (BCVA, LogMar) before primary ILM-TX was 1.18 ± 0.54 with a mean initial hole size of 681 ± 106 µm and a photoreceptor defect (PRD) of 1829 ± 474 µm. Five of six eyes showed a postoperative anatomical macular hole closure (83%). The mean BCVA after a mean follow-up of 9.3 ± 5.1 months was 0.83 ± 0.31 after a free ILM graft and 0.95 ± 0.79 after a pedunculated ILM flap. The PRD reduced to 1781 ± 713 µm after a free ILM graft and 1148 ± 378 µm after a pedunculated ILM flap. In group 2 (7 eyes), all patients had failed initial macular hole surgery closure. Prior to free ILM-TX BCVA was 1.05 ± 0.41, the hole size was 433 ± 183 µm and PRD was 2012 ± 718 µm. After a mean of 9.6 ± 4.1 months following ILM-TX, in six of seven eyes the FTMH hole was closed (86%), BCVA improved to 0.53 ± 0.34 and the PRD shortened to 843 ± 291 µm. Conclusion In most cases, with large FTMH or holes after failed vitrectomy plus ILM peeling, ILM-TX allows a hole closure. Functional outcomes show stabilization and sometimes even a slight improvement. Georg Thieme Verlag KG Stuttgart · New York.

  2. Six-Position, Frontal View Photography in Blepharoplasty: A Simple Method.

    PubMed

    Zhang, Cheng; Guo, Xiaoshuang; Han, Xuefeng; Tian, Yi; Jin, Xiaolei

    2018-02-26

    Photography plays a pivotal role in patient education, photo-documentation, preoperative planning and postsurgical evaluation in plastic surgeries. It has long been serving as a bridge that facilitated communication not only between patients and doctors, but also among plastic surgeons from different countries. Although several basic principles and photographic methods have been proposed, there is no internationally accepted photography that could provide both static and dynamic information in blepharoplasty. In this article, we introduced a novel six-position, frontal view photography for thorough assessment in blepharoplasty. From October 2013 to January 2017, 1068 patients who underwent blepharoplasty were enrolled in our clinical research. All patients received six-position, frontal view photography. Pictures were taken of the patients looking up, looking down, squeezing, smiling, looking ahead and with closed eyes. Conventionally, frontal view photography only contained the last two positions. Then, both novel six-position photographs and conventional two-position photographs were used to appraise postsurgical outcomes. Compared to conventional two-position, frontal view photography, six-position, frontal view photography can provide more detailed, thorough information about the eyes. It is of clinical significance in indicating underlying adhesion of skin/muscle/fat according to individual's features and assessing preoperative and postoperative dynamic changes and aesthetic outcomes. Six-position, frontal view photography is technically uncomplicated while exhibiting static, dynamic and detailed information of the eyes. This innovative method is favorable in eye assessment, especially for revision blepharoplasty. We suggest using six-position, frontal view photography to obtain comprehensive photographs. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  3. Physiological responses to the Coriolis illusion: effects of head position and vision.

    PubMed

    Westmoreland, David; Krell, Robert W; Self, Brian P

    2007-10-01

    Changes in sympathetic outflow during Type II spatial disorientation are well documented. In this study we investigated the influences of head position and eye state (open or closed) on sympathetic activation. There were 11 naive subjects (6 men, 5 women) who were tested in a General Aviation Trainer that accelerated at a subthreshold rate for 60 s until a constant angular velocity of 90 degrees x s(-1) was reached. Approximately 40 s later, subjects were instructed to tilt their heads along either the pitch or roll axis, stimulating a Coriolis illusion. Subjects reported the perceived intensity and duration of disorientation. Heart rate, heart rate variability, and electrodermal responses were recorded before, during, and after the period of disorientation. Each subject completed four trials, which were crossed combinations of head position and eye state. There were significant increases in heart rate and the electrodermal response during disorientation, but no significant change in heart rate variability. Head position had no significant effect on any physiological parameters or on the perceived intensity of disorientation; subjects reported a shorter duration of disorientation when the head was tilted into the roll versus the pitch axis. Eye state had no effect on heart rate, heart rate variability, or the intensity of disorientation, but the electrodermal response was somewhat greater, and the duration of disorientation shorter when eyes were open. The results suggest that head position and eye state (open or closed) do not need to be included as factors when investigating sympathetic outflow during a mild Coriolis illusion.

  4. Eye muscle prosthesis.

    PubMed

    Scott, A B; Miller, J M; Collins, C C

    1992-01-01

    We inserted a silicone rubber elastic band along the course of a paralyzed lateral rectus and of a paralyzed superior oblique to restore alignment and to provide a spring against which the antagonist could pull. The lateral rectus band has been in place for 7 years. It provides alignment and a field of single binocular vision of 20 degrees. The superior oblique band has been in place for 17 months. It provides alignment and single vision over 30 degrees from the primary position except for a restriction in upgaze-adduction to 25 degrees (Brown syndrome) and in downgaze-adduction to 20 degrees. Such engineered elastic bands are a useful addition to current surgical techniques for management of cases of paralysis and restriction.

  5. Acute air pollution-related symptoms among residents in Chiang Mai, Thailand.

    PubMed

    Wiwatanadate, Phongtape

    2014-01-01

    Open burnings (forest fires, agricultural, and garbage burnings) are the major sources of air pollution in Chiang Mai, Thailand. A time series prospective study was conducted in which 3025 participants were interviewed for 19 acute symptoms with the daily records of ambient air pollutants: particulate matter less than 10 microm in size (PM10), carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3). PM10 was positively associated with blurred vision with an adjusted odds ratio (OR) of 1.009. CO was positively associated with lower lung and heart symptoms with adjusted ORs of 1.137 and 1.117. NO2 was positively associated with nosebleed, larynx symptoms, dry cough, lower lung symptoms, heart symptoms, and eye irritation with the range of adjusted ORs (ROAORs) of 1.024 to 1.229. SO2 was positively associated with swelling feet, skin symptoms, eye irritation, red eyes, and blurred vision with ROAORs of 1.205 to 2.948. Conversely, O3 was negatively related to running nose, burning nose, dry cough, body rash, red eyes, and blurred vision with ROAORs of 0.891 to 0.979.

  6. Common determinants of body size and eye size in chickens from an advanced intercross line.

    PubMed

    Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; Fan, Qiao; Saw, Seang Mei; Guggenheim, Jeremy A

    2009-06-15

    Myopia development is characterised by an increased axial eye length. Therefore, identifying factors that influence eye size may provide new insights into the aetiology of myopia. In humans, axial length is positively correlated to height and weight, and in mice, eye weight is positively correlated with body weight. The purpose of this study was to examine the relationship between eye size and body size in chickens from a genetic cross in which alleles with major effects on eye and body size were segregating. Chickens from a cross between a layer line (small body size and eye size) and a broiler line (large body and eye size) were interbred for 10 generations so that alleles for eye and body size would have the chance to segregate independently. At 3 weeks of age, 510 chicks were assessed using in vivo high resolution A-scan ultrasonography and keratometry. Equatorial eye diameter and eye weight were measured after enucleation. The variations in eye size parameters that could be explained by body weight (BW), body length (BL), head width (HW) and sex were examined using multiple linear regression. It was found that BW, BL and HW and sex together predicted 51-56% of the variation in eye weight, axial length, corneal radius, and equatorial eye diameter. By contrast, the same variables predicted only 22% of the variation in lens thickness. After adjusting for sex, the three body size parameters predicted 45-49% of the variation in eye weight, axial length, corneal radius, and eye diameter, but only 0.4% of the variation in lens thickness. In conclusion, about half of the variation in eye size in the chickens of this broiler-layer advanced intercross line is likely to be determined by pleiotropic genes that also influence body size. Thus, mapping the quantitative trait loci (QTL) that determine body size may be useful in understanding the genetic determination of eye size (a logical inference of this result is that the 20 or more genetic variants that have recently been shown to influence human height may also be found to influence axial eye length). Furthermore, adjusting for body size will be essential in mapping pure eye size QTL in this chicken population, and may also have value in mapping eye size QTL in humans.

  7. Anterior Segment Ischemia after Strabismus Surgery

    PubMed Central

    Göçmen, Emine Seyhan; Atalay, Yonca; Evren Kemer, Özlem; Sarıkatipoğlu, Hikmet Yavuz

    2017-01-01

    A 46-year-old male patient was referred to our clinic with complaints of diplopia and esotropia in his right eye that developed after a car accident. The patient had right esotropia in primary position and abduction of the right eye was totally limited. Primary deviation was over 40 prism diopters at near and distance. The patient was diagnosed with sixth nerve palsy and 18 months after trauma, he underwent right medial rectus muscle recession. Ten months after the first operation, full-thickness tendon transposition of the superior and inferior rectus muscles (with Foster suture) was performed. On the first postoperative day, slit-lamp examination revealed corneal edema, 3+ cells in the anterior chamber and an irregular pupil. According to these findings, the diagnosis was anterior segment ischemia. Treatment with 0.1/5 mL topical dexamethasone drops (16 times/day), cyclopentolate hydrochloride drops (3 times/day) and 20 mg oral fluocortolone (3 times/day) was initiated. After 1 week of treatment, corneal edema regressed and the anterior chamber was clean. Topical and systemic steroid treatment was gradually discontinued. At postoperative 1 month, the patient was orthophoric and there were no pathologic symptoms besides the irregular pupil. Anterior segment ischemia is one of the most serious complications of strabismus surgery. Despite the fact that in most cases the only remaining sequel is an irregular pupil, serious circulation deficits could lead to phthisis bulbi. Clinical properties of anterior segment ischemia should be well recognized and in especially risky cases, preventative measures should be taken. PMID:28182149

  8. Tunnel Vision Prismatic Field Expansion: Challenges and Requirements

    PubMed Central

    Apfelbaum, Henry; Peli, Eli

    2015-01-01

    Purpose No prismatic solution for peripheral field loss (PFL) has gained widespread acceptance. Field extended by prisms has a corresponding optical scotoma at the prism apices. True expansion can be achieved when each eye is given a different view (through visual confusion). We analyze the effects of apical scotomas and binocular visual confusion in different designs to identify constraints on any solution that is likely to meet acceptance. Methods Calculated perimetry diagrams were compared to perimetry with PFL patients wearing InWave channel prisms and Trifield spectacles. Percept diagrams illustrate the binocular visual confusion. Results Channel prisms provide no benefit at primary gaze. Inconsequential extension was provided by InWave prisms, although accessible with moderate gaze shifts. Higher-power prisms provide greater extension, with greater paracentral scotoma loss, but require uncomfortable gaze shifts. Head turns, not eye scans, are needed to see regions lost to the apical scotomas. Trifield prisms provide field expansion at all gaze positions, but acceptance was limited by disturbing effects of central binocular visual confusion. Conclusions Field expansion when at primary gaze (where most time is spent) is needed while still providing unobstructed central vision. Paracentral multiplexing prisms we are developing that superimpose shifted and see-through views may accomplish that. Translational Relevance Use of the analyses and diagramming techniques presented here will be of value when considering prismatic aids for PFL, and could have prevented many unsuccessful designs and the improbable reports we cited from the literature. New designs must likely address the challenges identified here. PMID:26740910

  9. Tunnel Vision Prismatic Field Expansion: Challenges and Requirements.

    PubMed

    Apfelbaum, Henry; Peli, Eli

    2015-12-01

    No prismatic solution for peripheral field loss (PFL) has gained widespread acceptance. Field extended by prisms has a corresponding optical scotoma at the prism apices. True expansion can be achieved when each eye is given a different view (through visual confusion). We analyze the effects of apical scotomas and binocular visual confusion in different designs to identify constraints on any solution that is likely to meet acceptance. Calculated perimetry diagrams were compared to perimetry with PFL patients wearing InWave channel prisms and Trifield spectacles. Percept diagrams illustrate the binocular visual confusion. Channel prisms provide no benefit at primary gaze. Inconsequential extension was provided by InWave prisms, although accessible with moderate gaze shifts. Higher-power prisms provide greater extension, with greater paracentral scotoma loss, but require uncomfortable gaze shifts. Head turns, not eye scans, are needed to see regions lost to the apical scotomas. Trifield prisms provide field expansion at all gaze positions, but acceptance was limited by disturbing effects of central binocular visual confusion. Field expansion when at primary gaze (where most time is spent) is needed while still providing unobstructed central vision. Paracentral multiplexing prisms we are developing that superimpose shifted and see-through views may accomplish that. Use of the analyses and diagramming techniques presented here will be of value when considering prismatic aids for PFL, and could have prevented many unsuccessful designs and the improbable reports we cited from the literature. New designs must likely address the challenges identified here.

  10. Mapping your competitive position.

    PubMed

    D'Aveni, Richard A

    2007-11-01

    A price-benefit positioning map helps you see, through your customers' eyes, how your product compares with all its competitors in a market. You can draw such a map quickly and objectively, without having to resort to costly, time-consuming consumer surveys or subjective estimates of the excellence of your product and the shortcomings of all the others. Creating a positioning map involves three steps: First, define your market to include everything your customers might consider to be your product's competitors or substitutes. Second, track the price your customers actually pay (wholesale or retail? bundled or unbundled?) and identify what your customers see as your offering's primary benefit. This is done through regression analysis, determining which of the product's attributes (as described objectively by rating services, government agencies, R&D departments, and the like) explains most of the variance in its price. Third, draw the map by plotting on a graph the position of every product in the market you've selected according to its price and its level of primary benefit, and draw a line that runs through the middle of the points. What you get is a picture of the competitive landscape of your market, where all the products above the line command a price premium owing to some secondary benefit customers value, and all those below the line are positioned to earn market share through lower prices and reduced secondary benefits. Using examples as varied as Harley-Davidson motorcycles, Motorola cell phones, and the New York restaurant market, Tuck professor D'Aveni demonstrates some of the many ways the maps can be used: to locate unoccupied or less-crowded spaces in highly competitive markets, for instance, or to identify opportunities created through changes in the relationship between the primary benefit and prices. The maps even allow companies to anticipate--and counter-- rivals' strategies. R eprint RO711G

  11. Nitric oxide facilitates GABAergic neurotransmission in the cat oculomotor system: a physiological mechanism in eye movement control

    PubMed Central

    Moreno-López, Bernardo; Escudero, Miguel; Estrada, Carmen

    2002-01-01

    Nitric oxide (NO) synthesis by prepositus hypoglossi (PH) neurons is necessary for the normal performance of horizontal eye movements. We have previously shown that unilateral injections of NO synthase (NOS) inhibitors into the PH nucleus of alert cats produce velocity imbalance without alteration of the eye position control, both during spontaneous eye movements and the vestibulo-ocular reflex (VOR). This NO effect is exerted on the dorsal PH neuropil, whose fibres increase their cGMP content when stimulated by NO. In an attempt to determine whether NO acts by modulation of a specific neurotransmission system, we have now compared the oculomotor effects of NOS inhibition with those produced by local blockade of glutamatergic, GABAergic or glycinergic receptors in the PH nucleus of alert cats. Both glutamatergic antagonists used, 2-amino-5-phosphonovaleric acid (APV) and 2,3-dihydro-6-nitro-7-sulphamoyl-benzo quinoxaline (NBQX), induced a nystagmus contralateral to that observed upon NOS inhibition, and caused exponential eye position drift. In contrast, bicuculline and strychnine induced eye velocity alterations similar to those produced by NOS inhibitors, suggesting that NO oculomotor effects were due to facilitation of some inhibitory input to the PH nucleus. To investigate the anatomical location of the putative NO target neurons, the retrograde tracer Fast Blue was injected in one PH nucleus, and the brainstem sections containing Fast Blue-positive neurons were stained with double immunohistochemistry for NO-sensitive cGMP and glutamic acid decarboxylase. GABAergic neurons projecting to the PH nucleus and containing NO-sensitive cGMP were found almost exclusively in the ipsilateral medial vestibular nucleus and marginal zone. The results suggest that the nitrergic PH neurons control their own firing rate by a NO-mediated facilitation of GABAergic afferents from the ipsilateral medial vestibular nucleus. This self-control mechanism could play an important role in the maintenance of the vestibular balance necessary to generate a stable and adequate eye position signal. PMID:11927688

  12. Susceptibility of proliferating cells to benzo[a]pyrene-induced homologous recombination in mice.

    PubMed

    Bishop, A J; Kosaras, B; Carls, N; Sidman, R L; Schiestl, R H

    2001-04-01

    The pink-eyed unstable mutation, p(un), is the result of a 70 kb tandem duplication within the murine pink-eyed, p, gene. Deletion of one copy of the duplicated region by homologous deletion/recombination occurs spontaneously in embryos and results in pigmented spots in the fur and eye. Such deletion events are inducible by a variety of DNA damaging agents, as we have observed previously with both fur- and eye-spot assays. Here we describe a study of the effect of exposure to benzo[a]pyrene (B[a]P) at different times of development on reversion induction in the eye. Previously we, among others, have reported that the retinal pigment epithelium (RPE) displays a position effect variegation phenotype in the pattern of pink-eyed unstable reversions. Following an acute exposure to B[a]P or X-rays on the tenth day of gestation an increased frequency of reversion events was detected in a distinct region of the adult RPE. Examining exposure at different times of eye development reveals that both B[a]P and X-rays result in an increased frequency of reversion events, though the increase was only significant following B[a]P exposure, similar to our previous report limited to exposure on the tenth day of gestation. Examination of B[a]P-exposed RPE in the present study revealed distinct regions where the induced events lie and that the positions of these regions are found at increasing distances from the optic nerve the later the time of exposure. This position effect directly reflects the previously observed developmental pattern of the RPE, namely that cells in the regions most distal from the optic nerve are proliferating most vigorously. The numbers and positions of RPE cells displaying the transformed (pigmented) phenotype strongly advocate the proposal that dividing cells are at highest risk to deletions induced by carcinogens.

  13. Nd:YAG vitreolysis and pars plana vitrectomy: surgical treatment for vitreous floaters.

    PubMed

    Delaney, Y M; Oyinloye, A; Benjamin, L

    2002-01-01

    To determine the efficacy of Nd:YAG vitreolysis and pars plana vitrectomy in the treatment of vitreous floaters. This is a single centre retrospective study of 31 patients (42 eyes) who underwent 54 procedures, Nd:YAG vitreolysis or pars plana vitrectomy, for the treatment of vitreous floaters between January 1992 and December 2000. Main outcome measures were percentage symptomatic improvement following treatment and incidence of post-operative complications. Statistical analysis was performed using the Fisher exact test. Posterior vitreous detachment was the primary cause of floaters in all 42 eyes with co-existing vitreous veils in three eyes and asteroid hyalosis in two eyes. Thirty-nine of 42 eyes received Nd:YAG vitreolysis. Thirty-eight percent found Nd:YAG vitreolysis moderately improved their symptoms while 61.5% found no improvement. After an average of 14.7 months follow-up no post-operative complications were recorded. Fifteen eyes underwent a pars plana vitrectomy, one with combined phacoemulsification and posterior chamber implantation and 11 following unsuccessful laser vitreolysis. Pars plana vitrectomy resulted in full resolution of symptoms in 93.3% of eyes. One patient developed a post-operative retinal detachment which was successfully treated leaving the patient with 6/5 VA. Patients' symptoms from vitreous floaters are often underestimated resulting in no intervention. This paper shows Nd:YAG vitreolysis to be a safe but only moderately effective primary treatment conferring clinical benefit in one third of patients. Pars plana vitrectomy, while offering superior results, should be reserved for patients who remain markedly symptomatic following vitreolysis, until future studies further clarify its role in the treatment of patients with floaters and posterior vitreous detachment.

  14. Outcomes of Ahmed Valve Implant Following a Failed Initial Trabeculotomy and Trabeculectomy in Refractory Primary Congenital Glaucoma

    PubMed Central

    Dave, Paaraj; Senthil, Sirisha; Choudhari, Nikhil; Sekhar, Garudadri Chandra

    2015-01-01

    Purpose: The aim was to report the outcome of Ahmed glaucoma valve (AGV) (New World Medical, Inc., Rancho Cucamonga, CA, USA) implantation as a surgical intervention following an initial failed combined trabeculotomy + trabeculectomy (trab + trab) in refractory primary congenital glaucoma (RPCG). Materials and Methods: Retrospective chart review of 11 eyes of 8 patients who underwent implantation of AGV (model FP8) for RPCG between 2009 and 2011. Prior trab + trab had failed in all the eyes. Success was defined as an intraocular pressure (IOP) >5 and ≤ 18 mmHg during examination under anesthesia with or without medications and without serious complications or additional glaucoma surgery. Results: The mean age at AGV implantation was 15.4 ± 4.9 months. The mean preoperative IOP was 28 ± 5.7 mmHg which reduced to 13.6 ± 3.4 mmHg postoperatively at the last follow-up (P < 0.0001). The number of topical antiglaucoma medications reduced from a mean of 2.6 ± 0.5 to 1.6 ± 0.9 postoperatively (P = 0.009). The definition of qualified success was met in 10 (90%) eyes. One eye developed a shallow anterior chamber with choroidal detachment at 1-week, which resolved spontaneously with medications. None of the eyes developed a hypertensive phase. One eye had a long tube resulting in tube corneal touch that required trimming of the tube. One eye developed tube retraction, which was treated with a tube extender. The mean follow-up was 17.9 ± 9.3 (6.2-35.4) months. Conclusion: Managing RPCG remains a challenge. AGV implant was successful in a significant proportion of cases. PMID:25624676

  15. Identifying barriers to follow-up eye care for children after failed vision screening in a primary care setting.

    PubMed

    Su, Zhuo; Marvin, Elizabeth K; Wang, Bing Q; van Zyl, Tavé; Elia, Maxwell D; Garza, Esteban N; Salchow, Daniel J; Forster, Susan H

    2013-08-01

    To identify barriers to follow-up eye care in children who failed a visual acuity screening conducted by their primary care provider. Children aged 3-14 years who failed a visual acuity screening were identified. A phone survey with the parent of every child was conducted 4 months after the screening. Family demographics, parental awareness of childhood eye diseases and eye care for children, and barriers to follow-up eye care were assessed. Of 971 children sampled, 199 (20.5%) failed a visual acuity screening. The survey was completed by the parents of 58 children (29.1%), of whom 27 (46.6%) presented for follow-up examination. The most common reason for failure to follow-up was parental unawareness of screening results (29.3%). Follow-up rates were higher in children with previous eye examinations than in those without (81% versus 17%; P = 0.005) and in children who waited <2 months for a follow-up appointment than in those who had to wait longer (100% versus 63%; P = 0.024). Child's sex, ethnicity, and health insurance status, parent's marital, education and employment status, household income, and transportation access were not associated with statistically significant different follow-up rates. Parental unawareness of a failed visual acuity screening is an important barrier to obtaining follow-up. Strategies to improve follow-up rates after a failed visual acuity screening may include communicating the results clearly and consistently, providing education about the importance of timely follow-up, and offering logistic support for accessing eye appointments to families. Copyright © 2013 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  16. Randomised controlled trial of video clips and interactive games to improve vision in children with amblyopia using the I-BiT system

    PubMed Central

    Herbison, Nicola; MacKeith, Daisy; Vivian, Anthony; Purdy, Jon; Fakis, Apostolos; Ash, Isabel M; Cobb, Sue V; Eastgate, Richard M; Haworth, Stephen M; Gregson, Richard M; Foss, Alexander JE

    2016-01-01

    Background Traditional treatment of amblyopia involves either wearing a patch or atropine penalisation of the better eye. A new treatment is being developed on the basis of virtual reality technology allowing either DVD footage or computer games which present a common background to both eyes and the foreground, containing the imagery of interest, only to the amblyopic eye. Methods A randomised control trial was performed on patients with amblyopia aged 4–8 years with three arms. All three arms had dichoptic stimulation using shutter glass technology. One arm had DVD footage shown to the amblyopic eye and common background to both, the second used a modified shooter game, Nux, with sprite and targets presented to the amblyopic eye (and background to both) while the third arm had both background and foreground presented to both eyes (non-interactive binocular treatment (non-I-BiT) games). Results Seventy-five patients were randomised; 67 were residual amblyopes and 70 had an associated strabismus. The visual acuity improved in all three arms by approximately 0.07 logMAR in the amblyopic eye at 6 weeks. There was no difference between I-BiT DVD and non-I-BiT games compared with I-BiT games (stated primary outcome) in terms of gain in vision. Conclusions There was a modest vision improvement in all three arms. Treatment was well tolerated and safe. There was no difference between the three treatments in terms of primary stated outcomes but treatment duration was short and the high proportion of previously treated amblyopia and strabismic amblyopia disadvantaged dichoptic stimulation treatment. Trial registration number NCT01702727, results. PMID:26951772

  17. Clinical course of thyroid function and thyroid associated-ophthalmopathy in patients with euthyroid Graves' disease.

    PubMed

    Suzuki, Nami; Noh, Jaeduk Yoshimura; Kameda, Toshiaki; Yoshihara, Ai; Ohye, Hidemi; Suzuki, Miho; Matsumoto, Masako; Kunii, Yo; Iwaku, Kenji; Watanabe, Natsuko; Mukasa, Koji; Kozaki, Ai; Inoue, Toshu; Sugino, Kiminori; Ito, Koichi

    2018-01-01

    Euthyroid Graves' disease (EGD) is a rare condition defined as the presence of thyroid-associated ophthalmopathy (TAO) in patients with normal thyroid function. Due to the rarity of this disease, only a limited number of studies and case reports are available for further evaluation of the characteristics of the disease. The aim of this study was to examine the changes in the thyroid function, thyrotropin receptor antibodies (TRAb) and eye symptoms, and then determine whether TRAb is related to TAO in EGD patients. TRAb in this study was defined as including both thyrotropin-binding inhibitory immunoglobulin (TBII) and thyroid-stimulating immunoglobulin (TSAb). Medical records of patients diagnosed with EGD were reviewed. Ophthalmologists specializing in TAO examined the eyes of all subjects. Of the 58 patients diagnosed with EGD, 24.1% developed hyperthyroidism, while 3.4% developed hypothyroidism. A total of 72.4% of the 58 patients remained euthyroid throughout the entire follow-up period. At the initial presentation, TBII and TSAb were positive in 74.5% and 70.5%, respectively. Ophthalmic treatments were administered to 30 (51.7%) out of the 58 patients. A significant spontaneous improvement of the eye symptoms was found in 28 of the EGD patients who did not require eye treatments. EGD patients exhibited positive rates for both TBII and TSAb, with the number of the TRAb-positive patients gradually decreasing while the eye symptoms spontaneously improved over time. There were no correlations found between TRAb at initial presentation and the eye symptoms. TBII and TSAb were positive in about 70% of EGD patients at their initial visit. Thyroid functions of EGD patients who have been euthyroid for more than 6.7 years may continue to remain euthyroid in the future.

  18. 42 CFR 51c.102 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of primary care physicians in general or family practice, internal medicine, pediatrics, or... individual. (g) Physician means a licensed doctor of medicine or doctor of osteopathy. (h) Primary health..., preventive health education, children's eye and ear examinations, prenatal and post-partum care, prenatal...

  19. The Age-related Positivity Effect and Tobacco Warning Labels

    PubMed Central

    Roberts, Megan E.; Peters, Ellen; Ferketich, Amy K.; Klein, Elizabeth G.

    2016-01-01

    Objectives This study tested whether age is a factor in viewing time for tobacco warning labels. The approach drew from previous work demonstrating an age-related positivity effect, whereby older adults show preferences toward positive and away from negative stimuli. Methods Participants were 295 daily smokers from Appalachian Ohio (age range: 21–68). All participants took part in an eye-tracking paradigm that captured the attention paid to elements of health warning labels in the context of magazine advertisements. Participants also reported on their past cessation attempts and their beliefs about the dangers of smoking. Results Consistent with theory on age-related positivity, older age predicted weaker beliefs about smoking risks, but only among those with no past-year quit attempts. In support of our primary hypothesis, older age was also related to a lower percentage of time spent viewing tobacco warning labels, both overall (text + image) and for the graphic image alone. These associations remained after controlling for cigarettes smoked per day. Conclusions Overall, findings suggest that age is an important consideration for the design of future graphic warning labels and other tobacco risk communications. For older adults, warning labels may need to be tailored to overcome the age-related positivity effect. PMID:27617273

  20. Oculomotor Apraxia

    MedlinePlus

    ... a defect in, the control of voluntary purposeful eye movement. Children with this condition have difficulty moving their ... to compensate for this inability to initiate horizontal eye movements away from the straight-ahead gaze position. Typically, ...

  1. Examining Wrong Eye Implant Adverse Events in the Veterans Health Administration With a Focus on Prevention: A Preliminary Report.

    PubMed

    Neily, Julia; Chomsky, Amy; Orcutt, James; Paull, Douglas E; Mills, Peter D; Gilbert, Christina; Hemphill, Robin R; Gunnar, William

    2018-03-01

    The study goals were to examine wrong intraocular lens (IOL) implant adverse events in the Veterans Health Administration (VHA), identify root causes and contributing factors, and describe system changes that have been implemented to address this challenge. This study represents collaboration between the VHA's National Center for Patient Safety (NCPS) and the National Surgery Office (NSO). This report includes 45 wrong IOL implant surgery adverse events reported to established VHA NCPS and NSO databases between July 1, 2006, and June 31, 2014. There are approximately 50,000 eye implant procedures performed each year in the VHA. Wrong IOL implant surgery adverse events are reported by VHA facilities to the NCPS and the NSO. Two authors (A.C. and J.N.) coded the reports for event type (wrong lens or expired lens) and identified the primary contributing factor (coefficient κ = 0.837). A descriptive analysis was conducted, which included the reported yearly event rate. The main outcome measure was the reported wrong IOL implant surgery adverse events. There were 45 reported wrong IOL implant surgery adverse events. Between 2011 and June 30, 2014, there was a significant downward trend (P = 0.02, R = 99.7%) at a pace of -0.08 (per 10,000 cases) every year. The most frequently coded primary contributing factor was incomplete preprocedure time-out (n = 12) followed by failure to perform double check of preprocedural calculations based upon original data and implant read-back at the time the surgical eye implant was performed (n = 10). Preventing wrong IOL implant adverse events requires diligence beyond performance of the preprocedural time-out. In 2013, the VHA has modified policy to ensure double check of preprocedural calculations and implant read-back with positive impact. Continued analysis of contributing human factors and improved surgical team communication are warranted.

  2. Multifocal VEP and OCT findings in patients with primary open angle glaucoma: A cross-sectional study

    PubMed Central

    2012-01-01

    Bakground To evaluate objectively the anatomical and functional changes of optic nerve in eyes with primary open angle glaucoma (POAG) by the joint use of optical coherence tomography (OCT) and multifocal visual evoked potentials (mfVEP). Methods 29 eyes with open angle glaucoma and visual field defects, as well as 20 eyes of 10 age-matched control normal subjects were tested. All participants underwent a complete ophthalmological examination. Moreover, Humphrey visual field test, OCT examination and recording of mfVEP were performed. Amplitude and implicit time of mfVEP, as well as RNFL thickness were measured. Differences in density components of mfVEP and in RNFL thickness among POAG eyes and control eyes were examined using Student’s t-test. Results In glaucomatous eyes the mean Retinal Response Density (RRD) was lower than normal in ring 1, 2 and 3 of mfVEP (p < 0.0001). Specifically the mean amplitude of mfVEP in POAG eyes was estimated at 34.2 ± 17.6 nV/deg2, 6.9 ± 4.8 nV/deg2 and 2.6 ± 1.6 nV/deg2 in rings 1, 2 and 3 respectively. In contrast the mean implicit time was similar to control eyes. In addition, the mean RNFL thickness in POAG eyes was estimated at 76.8 ± 26.6 μm in the superior area, 52.1 ± 16.3 μm in the temporal area, 75.9 ± 32.5 μm in the inferior area and 58.6 ± 19.4 μm in the nasal area. There was a statistically significant difference in RNFL thickness in all peripapillary areas (p < 0.0001) between POAG eyes and controls, with superior and inferior area to present the highest decrease. Conclusions Our study shows that, although Standard Automatic Perimetry is the gold standard to evaluate glaucomatous neuropathy, the joint use of mfVEP and OCT could be useful in better monitoring glaucoma progression. PMID:22856337

  3. Clinical and laboratory characteristics of ocular syphilis: a new face in the era of HIV co-infection.

    PubMed

    Lee, Sun Young; Cheng, Vincent; Rodger, Damien; Rao, Narsing

    2015-12-01

    Ocular syphilis is reemerging as an important cause of uveitis in the new era of common co-infection with HIV. This study will reveal the clinical and laboratory characteristics in the group of individuals co-infected with ocular syphilis and HIV compared with HIV-negative individuals. In this retrospective observational case series, medical records of patients diagnosed with ocular syphilis with serologic support from 2008 to 2014 were reviewed. Ocular and systemic manifestation and laboratory profiles were reviewed. Twenty-nine eyes of 16 consecutive patients (10 HIV-positive and 6 HIV-negative) were included. All patients were males, and mean age of onset for ocular syphilis was 43 (mean 42.65 ± 13.13). In both HIV-positive and HIV-negative groups, ocular manifestations of syphilis were variable including anterior uveitis (4 eyes), posterior uveitis (8 eyes), panuveitis (13 eyes), and isolated papillitis (4 eyes). In HIV-positive patients, panuveitis was the most common feature (12/18 eyes, 67 %) and serum rapid plasma reagin (RPR) titers were significantly higher (range 1:64-1:16,348; mean 1:768; p = 0.018) than in HIV-negative patients. Upon the diagnosis of ocular syphilis in HIV-positive patients, HIV-1 viral load was high (median 206,887 copies/ml) and CD4 cell count ranged from 127 to 535 cells/ml (mean 237 ± 142; median 137). Regardless of HIV status, cerebrospinal fluid (CSF) exam was frequently abnormal: positive CSF fluorescent treponemal antibody absorption (FTA-ABS) or Venereal Disease Research Laboratory (VDRL) test results in seven patients or either elevated CSF WBC count or elevated CSF protein in six patients. Our results reveal that the patients with ocular syphilis with high serum RPR titers may have concomitant HIV infection requiring further testing for HIV status and ocular syphilis is likely associated with the central nervous system involvement and therefore needs to be managed according to the treatment recommendations for neurosyphilis.

  4. Smooth pursuitlike eye movements evoked by microstimulation in macaque nucleus reticularis tegmenti pontis.

    PubMed

    Yamada, T; Suzuki, D A; Yee, R D

    1996-11-01

    1. Smooth pursuitlike eye movements were evoked with low current microstimulation delivered to rostral portions of the nucleus reticularis tegmenti pontis (rNRTP) in alert macaques. Microstimulation sites were selected by the observation of modulations in single-cell firing rates that were correlated with periodic smoothpursuit eye movements. Current intensities ranged from 10 to 120 microA and were routinely < 40 microA. Microstimulation was delivered either in the dark with no fixation, 100 ms after a fixation target was extinguished, or during maintained fixation of a stationary or moving target. Evoked eye movements also were studied under open-loop conditions with the target image stabilized on the retina. 2. Eye movements evoked in the absence of a target rapidly accelerated to a constant velocity that was maintained for the duration of the microstimulation. Evoked eye speeds ranged from 3.7 to 23 deg/s and averaged 11 deg/s. Evoked eye speed appeared to be linearly related to initial eye position with a sensitivity to initial eye position that averaged 0.23 deg.s-1.deg-1. While some horizontal and oblique smooth eye movements were elicited, microstimulation resulted in upward eye movements in 89% of the sites. 3. Evoked eye speed was found to be dependent on microstimulation pulse frequency and current intensity. Within limits, evoked eye speed increased with increases in stimulation frequency or current intensity. For stimulation frequencies < 300-400 Hz, only smooth pursuit-like eye movements were evoked. At higher stimulation frequencies, accompanying saccades consistently were elicited. 4. Feedback of retinal image motion interacted with the evoked eye movements to decrease eye speed if the visual motion was in the opposite direction as the evoked, pursuit-like eye movements. 5. The results implicate rNRTP as part of the neuronal substrate that controls smooth-pursuit eye movements. NRTP appears to be divided functionally into a rostral, pursuit-related portion and a caudal, saccade-related area. rNRTP is a component of a corticopontocerebellar circuit that presumably involves the pursuit area of the frontal eye field and that parallels the middle and medial superior temporal cerebral cortical/dorsalateral pontine nucleus (MT/MST-DLPN-cerebellum) pathway known to be involved also with regulating smooth-pursuit eye movements.

  5. Effects of aircraft windscreens and canopies on HMT/D aiming accuracy: III

    NASA Astrophysics Data System (ADS)

    Task, H. Lee; Goodyear, Chuck

    1999-07-01

    Modern fighter aircraft windscreens and canopies are typically made of curved, transparent plastic for improved aero-dynamics and bird-strike protection. Since they are curved these transparencies often refract light in such a way that a pilot looking through the transparency will see a target in a location other than where it really is. This effect has been known for many years and methods to correct the aircraft head- up display (HUD) for these angular deviations have been developed and employed. The same problem occurs for helmet- mounted display/trackers (HMD/Ts) used for target acquisition. However, in this case, the pilot can look through any part of the transparency instead of being constrained to just the forward section as in the case of the HUD and his/her head position can be anywhere in a rather large motion box. To explore the magnitude of these aiming errors several F-15, F- 16, F-18, and F-22 transparency systems were measured from a total of 12 different eye positions centered around the HMD Eye (the HMD Eye was defined to be a point 1.25 inches to the right of the aircraft Design Eye). The collection of eye points for assessing HMT/D aiming accuracy were: HMD Eye, 3 inches left and right of HMD Eye, 2 inches above HMD Eye, and 2 inches forward of HMD Eye plus all combinations of these. Results from these measurements along with recommendations regarding means of assessing 'goodness' of correction algorithms are presented.

  6. Quality of life of eye amputated patients.

    PubMed

    Rasmussen, Marie L R; Ekholm, Ola; Prause, Jan U; Toft, Peter B

    2012-08-01

    To evaluate eye-amputated patients' health-related quality of life, perceived stress, self-rated health, job separation because of illness or disability and socioeconomic position. Patients were recruited from a tertiary referral centre situated in Copenhagen. Inclusion criteria were eye amputation, i.e. evisceration, enucleation, orbital exenteration or secondary implantation of an orbital implant during the period 1996-2003, and participation in a previous investigation (2005). In total, 159 eye-amputated patients were included, and completed a self-administered questionnaire containing health-related quality of life (SF-36), the perceived stress scale and answered questions about self-rated health, job changes because of illness or disability and socioeconomic status. These results were compared with findings from the Danish Health Interview Survey 2005. The eye-amputated patients had significantly (p < 0.05) lower scores (poorer health) on all SF-36 subscales and more perceived stress compared to the general population. In all, 43.3% of the patients rated their health as excellent or very good compared to 52.1% of the general population. In total, 25% of the study population has retired or changed to a part-time job because of eye disease. The percentage of eye amputated patients, who were divorced or separated, was twice as high as in the general population. The impact of an eye amputation is considerable. The quality of life, perceived stress and self-rated health of many eye-amputated patients are drastically changed. Eye amputation has a marked negative influence on job separation because of illness or disability and on socioeconomic position. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  7. The effect of lateral decubitus position on nocturnal intraocular pressure over a habitual 24-hour period in healthy adults.

    PubMed

    Hao, Jie; Zhen, Yi; Wang, Hao; Yang, Diya; Wang, Ningli

    2014-01-01

    To investigate the effect of lateral decubitus position (LDP) on nocturnal intraocular pressure (IOP) and the effect of LDP on 24-hour habitual IOP pattern in healthy subjects. Intraocular pressure was measured every 2-hours using an Accupen Applanation Tonometer (Accutome, USA). During the diurnal period (7:30 am, 9:30 am, 11:30 am, 1:30 pm, 3:30 pm, 5:30 pm, 7:30 pm, and 9:30 pm), IOP was measured in the sitting position under bright light (500-1000 lux) after the subjects had been seated for 5 min. The nocturnal IOP was measured in the supine position, right LDP, and left LDP, with randomized sequences, under dim light (<10 lux) at 11:30 pm, 1:30 am, 3:30 am, and 5:30 am. The subjects were awakened and maintained each position for 5 min before the measurement. The 24-hour habitual IOP patterns were obtained according to the nocturnal position (supine, right LDP and left LDP) for either eye. P<0.05 was considered to be significant. Nineteen healthy subjects were included with a mean age of 51.3±5.8 years. During the nocturnal period, a significant IOP difference was found between the dependent eye (the eye on the lower side) of LDP and the supine position, but not for all the nocturnal time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant, although the mean nocturnal IOP and the diurnal-nocturnal IOP change for the right and the left eye in the LDP pattern was slightly higher than that in the sitting-supine pattern. Significant nocturnal IOP differences existed between the dependent eye and the supine, but did not occur consistently for all time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant in healthy subjects.

  8. A Microcomputer-Based Software Package for Eye-Monitoring Research. Technical Report No. 434.

    ERIC Educational Resources Information Center

    McConkie, George W.; And Others

    A software package is described that collects and reduces eye behavior data (eye position and pupil size) using an IBM-PC compatible computer. Written in C language for speed and portability, it includes several features: (1) data can be simultaneously collected from other sources (such as electroencephalography and electromyography); (2)…

  9. Initial Scene Representations Facilitate Eye Movement Guidance in Visual Search

    ERIC Educational Resources Information Center

    Castelhano, Monica S.; Henderson, John M.

    2007-01-01

    What role does the initial glimpse of a scene play in subsequent eye movement guidance? In 4 experiments, a brief scene preview was followed by object search through the scene via a small moving window that was tied to fixation position. Experiment 1 demonstrated that the scene preview resulted in more efficient eye movements compared with a…

  10. Paying attention to saccadic intrusions.

    PubMed

    Gowen, E; Abadi, R V; Poliakoff, E

    2005-12-01

    Fixation to a target in primary gaze is invariably interrupted by physiological conjugate saccadic intrusions (SI). These small idiosyncratic eye movements (usually <1 degrees in amplitude) take the form of an initial horizontal fast eye movement away from the desired eye position, followed after a variable duration by a return saccade or drift. As the aetiology of SI is still unclear, it was the aim of this study to investigate whether SI are related to exogenous or endogenous attentional processes. This was achieved by varying (a) the "bottom-up" target viewing conditions (target presence, servo control of the target, target background, target size) and (b) the 'top-down' attentional state (instruction change--'look' or 'hold eyes steady' and passive fixation versus active--'respond to change' fixation) in 13 subjects (the number of participants in each task varied between 7 and 11). We also manipulated the orientation of pure exogenous attention through a cue-target task, during which subjects were required to respond to a target, preceded by a non-informative cue by either pressing a button or making a saccade towards the target. SI amplitude, duration, frequency and direction were measured. SI amplitude was found to be significantly higher when the target was absent and SI frequency significantly lower during open loop conditions. Target size and background influenced SI behaviour in an idiosyncratic manner, although there was a trend for subjects to exhibit lower SI frequencies and amplitudes when a patterned background was present and larger SI amplitudes with larger target sizes. SI frequency decreased during the "hold eyes steady" passive command as well as during active fixation but SI direction was not influenced by the exogenous cue-target task. These results suggest that SI are related to endogenous rather than exogenous attention mechanisms. Our experiments lead us to propose that SI represent shifts in endogenous attention that reflect a baseline attention state present during laboratory fixation tasks and may prove to be a useful tool to explore higher cortical control of fixation.

  11. Behavior of accessory abducens and abducens motoneurons during eye retraction and rotation in the alert cat.

    PubMed

    Delgado-Garcia, J M; Evinger, C; Escudero, M; Baker, R

    1990-08-01

    1. The activity of both accessory abducens (Acc Abd) and abducens (Abd) motoneurons (Mns) was recorded in the alert cat during eye retraction and rotational eye movements. Cats were fitted with two scleral coils, one measured rotational eye movements directly and the other retraction by distinguishing the translational component. 2. Acc Abd and Abd Mns were identified following antidromic activation from electrical stimulation of the ipsilateral VIth nerve. 3. In response to corneal air puffs, bursts of spikes were produced in all (n = 30) Acc Abd Mns. The burst began 7.2 +/- 1.2 (SD) ms after onset of the air puff and 8.9 +/- 1.9 ms before eye retraction. 4. Acc Abd Mns were silent throughout all types of rotational eye movements, and tonic activity was not observed during intervals without air-puff stimulation. 5. In contrast, all (n = 50) identified Abd Mns exhibited a burst and/or pause in activity preceding and during horizontal saccades as well as a tonic activity proportional to eye position. 6. Only 10% of Abd Mns fired a weak burst of spikes in response to air-puff stimulation. 7. We conclude that Acc Abd Mns are exclusively involved in eye retraction in the cat and that only a few Abd Mns have an eye-retraction signal added to their eye position and velocity signals. Thus any rotational eye-movement response described in retractor bulbi muscle must result from innervation by Mns located in the Abd and/or the oculomotor nuclei. 8. The organization of the prenuclear circuitry and species variation are discussed in view of the nictiating membrane extension response measured in associative learning.

  12. Incidence of eye cancer in Taiwan: an 18-year review.

    PubMed

    Cheng, C-Y; Hsu, W-M

    2004-02-01

    To describe the incidence and histologic patterns of eye cancers in Chinese in Taiwan. Beginning in 1979, cases of cancer in Taiwan were reported to the Taiwan National Cancer Registry. Information on all Chinese patients diagnosed with eye malignancies under the International Classification of Disease, Ninth Revision, site 190, was retrieved for analysis from the data bank of the Taiwan National Cancer Registry. In all, 733 cases with primary eye cancers were identified from 1979 to 1996, an 18-year period. The average annual age-standardized incidence of eye cancers was 2.46 per million population (2.57 for male and 2.33 for female). For cases less than 15 years of age, the most common eye malignancy was retinoblastoma (86.0%), followed by rhabdomyosarcoma (3.9%) and lymphoma (2.8%). For cases 15 years of age or older, the most common eye malignancy was melanoma (28.6%), followed by squamous cell sarcoma (21.0%) and lymphoma (20.8%). The time trends of the incidence of eye cancers were relatively stable over the 18-year period in Taiwan. Retinobalstoma, melanoma, and lymphoma were the three most common eye cancers in this Chinese population.

  13. Immunoreactive opsin and glial fibrillary acidic protein in persistent hyperplastic primary vitreous.

    PubMed

    Hara, S; Mito, T; Takahashi, M; Ohmura, M; Mizuno, K; Masuda, T

    1988-08-01

    An 8-month-old boy had an anterior type of persistent hyperplastic primary vitreous in the right eye. Results of needle biopsy, performed because of elevated intraocular pressure, disclosed clusters of blastic cells. The eye was enucleated on the suspicion of retinoblastoma. Histological examination showed retrolental fibrovascular tissue and retinal dysplasia. Immunoreactive opsin was detected in the innermost structures and in photoreceptor-like cells of rosettes. We conclude that photoreceptor cells differentiated to express opsin, even when neighbouring cells were abnormally arranged. An immunocytochemical study of glial fibrillary acidic protein demonstrated glial proliferation in the inner layer of the retina but not in the preretinal space.

  14. Retrobulbar chondrosarcoma in a dog.

    PubMed

    Ralić, M; Vasić, J; Jovanović, M; Cameron, B

    2014-01-01

    This paper presents a review of a dog, with a retrobulbar chondrosarcoma, which was admitted for surgery for visible changes in his eye during inspection. Orbital neoplasia in dogs may be primary and secondary. Sixty percent of orbital neoplasia in dogs are primary, ninety percent of which are malignant. Retrobulbar neoplasms are rare and in their early stage represent a diagnostic challenge. Chondrosarcoma of the skull is a slow-progressing malignant disease which occurs locally, aggressive with invasion into the surrounding tissues. Dogs with chondrosarcoma of the skull have life expectancy between 210 and 580 days - in our case it was 180 days - after the first alterations on the eye of the dog occurred.

  15. Matching between the light spots and lenslets of an artificial compound eye system

    NASA Astrophysics Data System (ADS)

    He, Jianzheng; Jian, Huijie; Zhu, Qitao; Ma, Mengchao; Wang, Keyi

    2017-10-01

    As the visual organ of many arthropods, the compound eye has attracted a lot of attention with the advantage of wide field-of-view, multi-channel imaging ability and high agility. Extended from this concept, a new kind of artificial compound eye device is developed. There are 141 lenslets which share one image sensor distributed evenly on a curved surface, thus it is difficult to distinguish the lenslets which the light spot belongs to during calibration and positioning process. Therefore, the matching algorithm is proposed based on the device structure and the principle of calibration and positioning. Region partition of lenslet array is performed at first. Each lenslet and its adjacent lenslets are defined as cluster eyes and constructed into an index table. In the calibration process, a polar coordinate system is established, and the matching can be accomplished by comparing the rotary table position in the polar coordinate system and the central light spot angle in the image. In the positioning process, the spot is paired to the correct region according to the spots distribution firstly, and the final results is determined by the dispersion of the distance from the target point to the incident ray in the region traversal matching. Finally, the experiment results show that the presented algorithms provide a feasible and efficient way to match the spot to the lenslet, and perfectly meet the needs in the practical application of the compound eye system.

  16. A comparison of facial color pattern and gazing behavior in canid species suggests gaze communication in gray wolves (Canis lupus).

    PubMed

    Ueda, Sayoko; Kumagai, Gaku; Otaki, Yusuke; Yamaguchi, Shinya; Kohshima, Shiro

    2014-01-01

    As facial color pattern around the eyes has been suggested to serve various adaptive functions related to the gaze signal, we compared the patterns among 25 canid species, focusing on the gaze signal, to estimate the function of facial color pattern in these species. The facial color patterns of the studied species could be categorized into the following three types based on contrast indices relating to the gaze signal: A-type (both pupil position in the eye outline and eye position in the face are clear), B-type (only the eye position is clear), and C-type (both the pupil and eye position are unclear). A-type faces with light-colored irises were observed in most studied species of the wolf-like clade and some of the red fox-like clade. A-type faces tended to be observed in species living in family groups all year-round, whereas B-type faces tended to be seen in solo/pair-living species. The duration of gazing behavior during which the facial gaze-signal is displayed to the other individual was longest in gray wolves with typical A-type faces, of intermediate length in fennec foxes with typical B-type faces, and shortest in bush dogs with typical C-type faces. These results suggest that the facial color pattern of canid species is related to their gaze communication and that canids with A-type faces, especially gray wolves, use the gaze signal in conspecific communication.

  17. Who Teaches Primary Physical Education? Change and Transformation through the Eyes of Subject Leaders

    ERIC Educational Resources Information Center

    Jones, Luke; Green, Ken

    2017-01-01

    Primary physical education (PE) lessons tend to be taught by one, or a combination of, three different groups: generalist classroom teachers, specialist primary PE teachers and so-called adults other than teachers, who are almost exclusively sports coaches. Drawing upon data gathered from one-to-one interviews with 36 subject leaders (SLs), this…

  18. Modified Monovision With Spherical Aberration to Improve Presbyopic Through-Focus Visual Performance

    PubMed Central

    Zheleznyak, Len; Sabesan, Ramkumar; Oh, Je-Sun; MacRae, Scott; Yoon, Geunyoung

    2013-01-01

    Purpose. To investigate the impact on visual performance of modifying monovision with monocularly induced spherical aberration (SA) to increase depth of focus (DoF), thereby enhancing binocular through-focus visual performance. Methods. A binocular adaptive optics (AO) vision simulator was used to correct both eyes' native aberrations and induce traditional (TMV) and modified (MMV) monovision corrections. TMV was simulated with 1.5 diopters (D) of anisometropia (dominant eye at distance, nondominant eye at near). Zernike primary SA was induced in the nondominant eye in MMV. A total of four MMV conditions were tested with various amounts of SA (±0.2 and ±0.4 μm) and fixed anisometropia (1.5 D). Monocular and binocular visual acuity (VA) and contrast sensitivity (CS) at 10 cyc/deg and binocular summation were measured through-focus in three cyclopledged subjects with 4-mm pupils. Results. MMV with positive SA had a larger benefit for intermediate distances (1.5 lines at 1.0 D) than with negative SA, compared with TMV. Negative SA had a stronger benefit in VA at near. DoF of all MMV conditions was 3.5 ± 0.5 D (mean) as compared with TMV (2.7 ± 0.3 D). Through-focus CS at 10 cyc/deg was significantly reduced with MMV as compared to TMV only at intermediate object distances, however was unaffected at distance. Binocular summation was absent at all object distances except 0.5 D, where it improved in MMV by 19% over TMV. Conclusions. Modified monovision with SA improves through-focus VA and DoF as compared with traditional monovision. Binocular summation also increased as interocular similarity of image quality increased due to extended monocular DoF. PMID:23557742

  19. Association of narrow angles with anterior chamber area and volume measured with anterior-segment optical coherence tomography.

    PubMed

    Wu, Ren-Yi; Nongpiur, Monisha E; He, Ming-Guang; Sakata, Lisandro M; Friedman, David S; Chan, Yiong-Huak; Lavanya, Raghavan; Wong, Tien-Yin; Aung, Tin

    2011-05-01

    To describe the measurement of anterior chamber area and anterior chamber volume by anterior-segment optical coherence tomography and to investigate the association of these parameters with the presence of narrow angles. This was a cross-sectional study of subjects aged at least 50 years without ophthalmic symptoms recruited from a community clinic. All participants underwent standardized ocular examination and anterior-segment optical coherence tomography. Customized software was used to measure anterior chamber area (cross-sectional area bounded by the corneal endothelium, anterior surface of iris, and lens within the pupil) and anterior chamber volume (calculated by rotating the anterior chamber area 360° around a vertical axis through the midpoint of the anterior chamber area). An eye was considered to have narrow angles if the posterior pigmented trabecular meshwork was not visible for at least 180° on gonioscopy with the eye in the primary position. A total of 1922 subjects were included in the final analyses, 317 (16.5%) of whom had narrow angles. Mean anterior chamber area (15.6 vs 21.1 mm(2); P < .001) and anterior chamber volume (97.6 vs 142.1 mm(3); P < .001) were smaller in eyes with narrow angles compared with those in eyes without narrow angles. After adjusting for age, sex, anterior chamber depth, axial length, and pupil size, smaller anterior chamber area (odds ratio, 53.2; 95% confidence interval, 27.1-104.5) and anterior chamber volume (odds ratio, 40.2; 95% confidence interval, 21.5-75.2) were significantly associated with the presence of narrow angles. Smaller anterior chamber area and anterior chamber volume were independently associated with narrow angles in Singaporeans, even after controlling for other known ocular risk factors.

  20. The efficacy of Ahmed glaucoma valve drainage devices in cases of adult refractory glaucoma in Indian eyes

    PubMed Central

    Parihar, Jitendra K S; Vats, Devendra P; Maggon, Rakesh; Mathur, Vijay; Singh, Anirudh; Mishra, Sanjay K

    2009-01-01

    Aim: To evaluate the efficacy of Ahmed glaucoma valve (AGV) drainage devices in cases of adult refractory glaucoma in Indian eyes. Settings and Design: Retrospective interventional case series study. Materials and Methods: Fifty two eyes of 32 patients of refractory glaucoma in the age group of 35 to 60 years who underwent AGV implantation with or without concomitant procedures from January 2003 to Jan 2007 were studied. Of these, 46 eyes (88%) had undergone filtering surgery earlier whereas remaining eyes underwent primary AGV implantation following failure of maximal medical therapy. The follow up ranged between 12 months to 48 months Results: Eighteen eyes (35%) had undergone phacoemulsification with AGV implantation, penetrating keratoplasty (PK) with AGV and intraocular lens (IOL) implantation in 13 eyes (25%), AGV over preexisting IOL in eight eyes (15%). AGV implantation alone was done in six (11%) eyes. Anterior chamber (AC) reconstruction with secondary IOL and AGV was performed in the remaining eyes. The mean intra ocular pressure (IOP) decreased from 36.3 ± 15.7 mm Hg to 19.6 ± 9.2 mm Hg. Complete success as per criteria was achieved in 46 eyes (88%). None of the eyes had failure to maintain IOP control following AGV. Conclusion: The AGV resulted in effective and sustained control of IOP in cases of adult refractory glaucoma in intermediate follow up. PMID:19700871

  1. [Firework-related eye trauma from 2005 to 2013].

    PubMed

    Unterlauft, J D; Wiedemann, P; Meier, P

    2014-09-01

    Fireworks combusted during New Year's Eve festivities can cause different eye traumas which often need complex reconstructive surgery. It was our aim to systematically analyse these eye trauma cases which were treated at our clinic during the last eight years. Age, gender, side, trauma mechanism, treatment methods and outcome were analysed for all eye trauma cases caused by fireworks during the New Year's Eve celebrations from 2006 to 2013. For statistical analysis all trauma cases were divided into two groups of major and non-major eye trauma. The total number of patients treated was 122 (28 women, 94 men, mean age 26.2±13.0 years) with 137 traumatised eyes (77 right, 60 left). 24.6% of patients were ≤18 years of age. 76.2% were bystanders. 50 eyes from 46 patients (37.7%) suffered from major eye trauma. 26 patients (21.3%) were hospitalised. 8 eyes (5.8%) suffered from a penetrating injury or globe rupture and underwent primary reconstructive surgery. Further 16 eyes (11.7%) suffered from major eye trauma without open globe injury. In the aftermath 11 eyes (8.0%) went blind (visual acuity<1/50). Gender, side and role of the patient were not significantly different between the two groups. Mean age was significantly higher in the major eye trauma group (p=0.01). Young male bystanders have a high risk for suffering from eye trauma caused by fireworks. However older patients suffer from major eye trauma more often. More education and prophylaxis of eye trauma caused by fireworks is desirable. Georg Thieme Verlag KG Stuttgart · New York.

  2. Primary extranodal marginal zone lymphoma of the uvea associated with massive diffuse epibulbar extension and focal infiltration of the optic nerve and meninges, clinically presented as uveitis masquerade syndrome: a case report.

    PubMed

    Rasić, D M; Stanković, Z; Terzić, T; Kovacević, D; Koturović, Z; Marković, V

    2010-09-01

    To report a clinical, histopathological and immunohistochemical findings in a case of primary extranodal marginal zone lymphoma of the uvea associated with massive diffuse extraocular episcleral extension and focal infiltration of the optic nerve and meninges, clinically presented as longstanding uveitis masquerade syndrome. Interventional case reports with histopathological correlation. We describe a 80-year-old male patient with a 3-year history of chronic recurrent hypertensive (pan) uveitis associated with ocular pain, unresponsive to topical and systemic anti-inflammatory, immunosuppressive, antibiotic/antiviral and antiglaucomatous therapy. Because the eye was not salvageable with conservative treatment, enucleation of blind and painful eye was performed. Findings from histopathological and immunohistochemistry examination of the enucleated eye showed an extranodal marginal zone lymphoma of the uveal tract with massive epibulbar extension and optic nerve and meningeal penetration. During almost 3 years of clinical course and 6 months after the enucleation, there were no systemic manifestations of lymphoma, and patient has not required subsequent treatment. Primary lymphoproliferative lesions of the uvea, comprising the iris, ciliary body and choroid are very rare, associated with epibulbar extension extremely and with optic nerve and menigeal penetration exceptionally. Despite its rarity, primary lymphoma of the uvea should be included in the differential diagnosis particularly in older patients with longstanding recurrent uveitis.

  3. Ultrasonographic biometry of the normal eye of the Persian cat.

    PubMed

    Mirshahi, A; Shafigh, S H; Azizzadeh, M

    2014-07-01

    To describe the normal ultrasonographic biometry of the Persian cat's eyes using B-mode ultrasonography. In a cross-sectional study, 20 healthy Persian cats with no history of previous ophthalmic disease were examined. Ocular biometry of the left and right eyes was measured using B-mode ultrasonography. Comparison of the average measurements between left and right eyes and between vertical and horizontal planes was performed using paired-sample t test. Correlation of ocular parameters with sex, age, head circumference and eye colour was evaluated. Mean ± standard deviation (SD) measurements of the ocular structures of anterior chamber, lens thickness, vitreous chamber and anterior to posterior dimension of the globe in 40 eyes were 4.1 ± 0.7, 7.7 ± 0.5, 8.2 ± 0.4 and 20.7 ± 1.0 mm, respectively. No significant difference was found between the ocular biometry of the left and right eyes or the horizontal and vertical planes. Of the ocular parameters, the following had a significant positive correlation with head circumference: axial globe length, anterior chamber and lens thickness. The vitreous body had a positive correlation with age. Regarding the breed predisposition of Persian cats to ocular problems, the present study provides baseline information for further clinical investigations of ocular abnormalities using B-mode ultrasonography. © 2014 Australian Veterinary Association.

  4. The Effect of Topical Ocular Anesthetic Proparacaine on Conjunctival and Nasal Mucosal Flora in Dry Eye Disease Patients.

    PubMed

    Onerci Celebi, Ozlem; Celebi, Ali Riza Cenk

    2018-04-09

    The aim of this study was to investigate the effect of topically applied ocular anesthetic proparacaine on conjunctival and nasal bacterial mucosal flora in patients with dry eye disease. A Schirmer test was done with (group 1) and without (group 2) topical anesthetic proparacaine to 40 patients in each group. Conjunctival and nasal cultures were obtained before and 10 min after performing the Schirmer test. The bacterial culture results and the isolated bacteria were recorded in two groups. Patients' mean age was 62 years (70 female, 10 male). Before the application of topical anesthetic, 50 (62.5%) and 62 (77.5%) had positive conjunctival and nasal culture, respectively, with the most commonly isolated organism being coagulase-negative Staphylococcus in each group. In group 1 the conjunctival bacterial culture positivity rate decreased from 26 (65%) to six (15%) eyes ( p < 0.001); however, this rate decreased slightly from 24 (60%) to 20 (50%) eyes in group 2 ( p > 0.05). For the nasal cultures, the bacterial culture positivity rate decreased from 80% to 20% and from 75% to 65% in groups 1 ( p < 0.001) and 2 ( p > 0.05), respectively. Topical ocular anesthetic proparacaine has antibacterial activity in both conjunctival and nasal flora in patients with dry eye disease.

  5. Image-size differences worsen stereopsis independent of eye position

    PubMed Central

    Vlaskamp, Björn N. S.; Filippini, Heather R.; Banks, Martin S.

    2010-01-01

    With the eyes in forward gaze, stereo performance worsens when one eye’s image is larger than the other’s. Near, eccentric objects naturally create retinal images of different sizes. Does this mean that stereopsis exhibits deficits for such stimuli? Or does the visual system compensate for the predictable image-size differences? To answer this, we measured discrimination of a disparity-defined shape for different relative image sizes. We did so for different gaze directions, some compatible with the image-size difference and some not. Magnifications of 10–15% caused a clear worsening of stereo performance. The worsening was determined only by relative image size and not by eye position. This shows that no neural compensation for image-size differences accompanies eye-position changes, at least prior to disparity estimation. We also found that a local cross-correlation model for disparity estimation performs like humans in the same task, suggesting that the decrease in stereo performance due to image-size differences is a byproduct of the disparity-estimation method. Finally, we looked for compensation in an observer who has constantly different image sizes due to differing eye lengths. She performed best when the presented images were roughly the same size, indicating that she has compensated for the persistent image-size difference. PMID:19271927

  6. Optic Neuropathy Secondary to Polyarteritis Nodosa, Case Report, and Diagnostic Challenges.

    PubMed

    Vazquez-Romo, Kristian A; Rodriguez-Hernandez, Adrian; Paczka, Jose A; Nuño-Suarez, Moises A; Rocha-Muñoz, Alberto D; Zavala-Cerna, Maria G

    2017-01-01

    To describe a case of optic neuropathy as a primary manifestation of polyarteritis nodosa (PAN) and discuss diagnostic challenges. Case report. A 41-year-old Hispanic man presented with a 2-day history of reduced visual acuity in his left eye. Physical examination revealed a complete visual field loss in the affected eye. Best-corrected visual acuity (BCVA) in the left eye was hand motion, and fundus examination revealed a hyperemic optic disk with blurred margins, swelling, retinal folds, dilated veins, and normal size arteries. BCVA in the right eye was 20/20; no anomalies were seen during examination of the fundus. The patient was started on oral corticosteroids and once the diagnosis of PAN was made, cyclophosphamide was added to the treatment regimen. Six months later, the patient recovered his BCVA to 20/20 in his left eye. Rarely does optic neuropathy present as a primary manifestation of PAN; nevertheless, it represents an ophthalmologic emergency that requires expeditious anti-inflammatory and immunosuppressive treatment to decrease the probability of permanent visual damage. Unfortunately, diagnosing PAN is challenging as it necessitates a high index of suspicion. In young male patients who present for the first time with diminished visual acuity, ophthalmologists become cornerstones in the suspicion of this diagnosis and should be responsible for continuing the study until a diagnosis is reached to ensure rapid commencement of immunosuppressive treatment.

  7. Effect of laser peripheral iridotomy on anterior chamber angle anatomy in primary angle closure spectrum eyes

    PubMed Central

    Kansara, Seema; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Bell, Nicholas P.; Mankiewicz, Kimberly A.; Feldman, Robert M.

    2015-01-01

    Purpose To evaluate the change in trabecular-iris circumference volume (TICV) after laser peripheral iridotomy (LPI) in primary angle closure (PAC) spectrum eyes Patients and Methods Forty-two chronic PAC spectrum eyes from 24 patients were enrolled. Eyes with anterior chamber abnormalities affecting angle measurement were excluded. Intraocular pressure, slit lamp exam, and gonioscopy were recorded at each visit. Anterior segment optical coherence tomography (ASOCT) with 3D mode angle analysis scans were taken with the CASIA SS-1000 (Tomey Corp., Nagoya, Japan) before and after LPI. Forty-two pre-LPI ASOCT scans and 34 post-LPI ASOCT scans were analyzed using the Anterior Chamber Analysis and Interpretation (ACAI, Houston, TX) software. A mixed-effect model analysis was used to compare the trabecular-iris space area (TISA) changes among 4 quadrants, as well as to identify potential factors affecting TICV. Results There was a significant increase in all average angle parameters after LPI (TISA500, TISA750, TICV500, and TICV750). The magnitude of change in TISA500 in the superior angle was significantly less than the other angles. The changes in TICV500 and TICV750 were not associated with any demographic or ocular characteristics. Conclusion TICV is a useful parameter to quantitatively measure the effectiveness of LPI in the treatment of eyes with PAC spectrum disease. PMID:26066504

  8. The Handicapped Can Dance Too!

    ERIC Educational Resources Information Center

    Lloyd, Marcia L.

    1978-01-01

    A program of dance therapy activities can offer handicapped individuals positive experiences in such areas as body image, spatial awareness, self-confidence, hand-eye/foot-eye coordination, visual focusing, balance and social relations. (Author/MJB)

  9. Prevalence and phenomenology of eye tics in Gilles de la Tourette syndrome.

    PubMed

    Martino, Davide; Cavanna, Andrea E; Robertson, Mary M; Orth, Michael

    2012-10-01

    Eye tics seem to be common in Gilles de la Tourette syndrome (GTS). We analyzed the frequency and clinical characteristics of eye tics in 212 GTS patients. Of the 212 patients, 201 (94.8 %) reported eye tics in their life-time; 166 (78.3 %) reported eye movement tics (rolling eyes up/down, eyes looking sideways, staring), and 194 (91.5 %) eyelid/eyebrow movement tics (frowning, raising eyebrows, blinking or winking). Patients with eye movement tics were younger at age of GTS onset (7.1 ± 4 years) than those without (8.9 ± 6.8; p = 0.024). Tic severity positively correlated to lifetime history of eye and/or eyelid/eyebrow movement tics. Our data confirm that eye and eyelid/eyebrow movement tics are very common in GTS, and most patients have several types of eye tics over time. Eye tic phenomenology was similar in patients with or without co-morbidity. Eye tics are therefore likely to be a core feature of GTS and should be routinely evaluated in order to strengthen the clinician's confidence in diagnosing GTS.

  10. Science Unlimited: Grades K-6 Competency Matrix.

    ERIC Educational Resources Information Center

    Pennsylvania State Dept. of Education, Harrisburg. Div. of Arts and Sciences.

    This competency matrix matches the primary and intermediate Science Unlimited lessons with the established competencies which appear in the Science Unlimited competency continuum. Primary lessons deal with: investigating dripping faucets; classification/sorting; smell; eyes; color; air; weather; observation and description; mystery boxes; change;…

  11. Effects of oral sea buckthorn oil on tear film Fatty acids in individuals with dry eye.

    PubMed

    Järvinen, Riikka L; Larmo, Petra S; Setälä, Niko L; Yang, Baoru; Engblom, Janne Rk; Viitanen, Matti H; Kallio, Heikki P

    2011-09-01

    Evaporative dry eye is associated with meibomian gland dysfunction and abnormalities of the tear film lipids. Dry eye is known to be affected positively by intake of linoleic and γ-linolenic acids and n-3 fatty acids. Oral sea buckthorn (Hippophaë rhamnoides) (SB) oil, which contains linoleic and α-linolenic acids and antioxidants, has shown beneficial effects on dry eye. The objective was to investigate whether supplementation with SB oil affects the composition of the tear film fatty acids in individuals reporting dry eye. One hundred participants were randomized to this parallel, double-blind, placebo-controlled study, which 86 of them completed. The participants daily consumed 2 g of SB or placebo oil for 3 months. Tear film samples were collected at the beginning, during, and at the end of the intervention and 1 to 2 months later. Tear film fatty acids were analyzed as methyl esters by gas chromatography. There were no group differences in the changes in fatty acid proportions during the intervention (branched-chain fatty acids: P = 0.49, saturated fatty acids: P = 0.59, monounsaturated fatty acids: P = 0.53, and polyunsaturated fatty acids: P = 0.16). The results indicate that the positive effects of SB oil on dry eye are not mediated through direct effects on the tear film fatty acids. Carotenoids and tocopherols in the oil or eicosanoids produced from the fatty acids of the oil may have a positive effect on inflammation and differentiation of the meibomian gland cells.

  12. Remote vs. head-mounted eye-tracking: a comparison using radiologists reading mammograms

    NASA Astrophysics Data System (ADS)

    Mello-Thoms, Claudia; Gur, David

    2007-03-01

    Eye position monitoring has been used for decades in Radiology in order to determine how radiologists interpret medical images. Using these devices several discoveries about the perception/decision making process have been made, such as the importance of comparisons of perceived abnormalities with selected areas of the background, the likelihood that a true lesion will attract visual attention early in the reading process, and the finding that most misses attract prolonged visual dwell, often comparable to dwell in the location of reported lesions. However, eye position tracking is a cumbersome process, which often requires the observer to wear a helmet gear which contains the eye tracker per se and a magnetic head tracker, which allows for the computation of head position. Observers tend to complain of fatigue after wearing the gear for a prolonged time. Recently, with the advances made to remote eye-tracking, the use of head-mounted systems seemed destined to become a thing of the past. In this study we evaluated a remote eye tracking system, and compared it to a head-mounted system, as radiologists read a case set of one-view mammograms on a high-resolution display. We compared visual search parameters between the two systems, such as time to hit the location of the lesion for the first time, amount of dwell time in the location of the lesion, total time analyzing the image, etc. We also evaluated the observers' impressions of both systems, and what their perceptions were of the restrictions of each system.

  13. Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruijf, Willy J.M. de, E-mail: kruijf.de.w@bvi.nl; Verstraete, Jan; Neustadter, David

    2013-02-01

    Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performedmore » to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.« less

  14. Patient positioning based on a radioactive tracer implanted in patients with localized prostate cancer: a performance and safety evaluation.

    PubMed

    de Kruijf, Willy J M; Verstraete, Jan; Neustadter, David; Corn, Benjamin W; Hol, Sandra; Venselaar, Jack L M; Davits, Rob J; Wijsman, Bart P; Van den Bergh, Laura; Budiharto, Tom; Oyen, Raymond; Haustermans, Karin; Poortmans, Philip M P

    2013-02-01

    To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ((192)Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. [Two cases of Vogt-Koyanagi-Harada disease presenting shallow anterior chamber].

    PubMed

    Takemoto, Daisuke; Ijiri, Shigeyuki; Shimizu, Michiharu; Higashide, Tomomi; Sugiyama, Kazuhisa

    2015-05-01

    We report two cases of Vogt-Koyanagi-Harada disease (VKH) in which shallow anterior chambers were improved after steroid pulse therapy. The patients were women aged 65 and 72. They had headaches, decreased visual acuity and shallow anterior chamber in both eyes. There was no inflammation in the anterior chamber. Ultrasound biomicroscopy (UBM) showed ciliary edema, ciliochoroidal detachment, and angle closure. One case showed high intraocular pressure (IOP), and a diagnosis of acute primary angle closure was made. Although cataract surgery was performed in the left eye, postoperative optical coherence tomography (OCT) revealed serous retinal detachment in both eyes. The shallow anterior chamber and UBM findings were improved and serous retinal detachment disappeared after steroid pulse therapy in both cases. VKH may cause shallow anterior chamber and angle closure. The inflammatory changes of VKH in the anterior segment, i. e. ciliary edema and ciliochoroidal detachment, may exacerbate the shallow anterior chambers and narrow angles and result in an acute increase in IOP in eyes with short axial length. VKH associated with shallow anterior chamber may be misdiagnosed as acute primary angle closure. For differential diagnosis, examinations of the ocular fundus including OCT are useful.

  16. The coordinate system of the eye in cataract surgery: Performance comparison of the circle Hough transform and Daugman's algorithm

    NASA Astrophysics Data System (ADS)

    Vlachynska, Alzbeta; Oplatkova, Zuzana Kominkova; Sramka, Martin

    2017-07-01

    The aim of the work is to determine the coordinate system of an eye and insert a polar-axis system into images captured by a slip lamp. The image of the eye with the polar axis helps a surgeon accurately implant toric intraocular lens in the required position/rotation during the cataract surgery. In this paper, two common algorithms for pupil detection are compared: the circle Hough transform and Daugman's algorithm. The procedures were tested and analysed on the anonymous data set of 128 eyes captured at Gemini eye clinic in 2015.

  17. Establishing the tolerability and performance of tamarind seed polysaccharide (TSP) in treating dry eye syndrome: results of a clinical study.

    PubMed

    Rolando, Maurizio; Valente, Cristiana

    2007-03-29

    One of the problems arising from available preparations for dry eye syndrome is the limited residence time of products on the ocular surface. In this paper, we look at an innovative new treatment for dry eye, tamarind seed polysaccharide (TSP). TSP possesses mucomimetic, mucoadhesive and pseudoplastic properties. The 'mucin-like' molecular structure of TSP is similar to corneal and conjunctival mucin 1 (MUC1), a transmembrane glycoprotein thought to play an essential role in protecting and wetting the corneal surface and may explain its increased retention on the eye surface. The activity of TSP and hyaluronic acid (HA) in the treatment of dry eye syndrome was compared in an open-label, randomised, single-centre clinical study. Thirty patients were randomised to receive three or more applications per day of either TSP 0.5%, TSP 1% or HA 0.2% (Hyalistiltrade mark) over a period of 90 days. The primary objective of tolerability was assessed by visual analogue scale (VAS), scoring of specific symptoms and the incidence of adverse events. Secondary objectives included improvement in stability of the precorneal tear film, subjective symptoms and corneal and conjunctival staining. TSP 0.5% and 1% were comparable to HA 0.2% with regard to both primary and secondary objective parameters.TSP 1% showed benefits over HA 0.2% for the subjective symptoms; trouble blinking, ocular burning and foreign body sensation. This study suggests that TSP 0.5% and 1% offer at least equivalent relief to HA 0.2% for dry eye syndrome. All treatments demonstrated optimal tolerability and are suitable for frequent use in the therapy of dry eye.TSP 1% produced promising results in terms of improvements in certain patient symptoms and suggests benefits of the TSP formulation. This study paves the way for a larger study to further establish the performance and safety of TSP compared with HA and highlights the need to expand this therapeutic agent to a wider dry eye population.

  18. Topography of eye-position sensitivity of saccades evoked electrically from the cat's superior colliculus.

    PubMed

    McIlwain, J T

    1990-03-01

    Saccades evoked electrically from the deep layers of the superior colliculus have been examined in the alert cat with its head fixed. Amplitudes of the vertical and horizontal components varied linearly with the starting position of the eye. The slopes of the linear-regression lines provided an estimate of the sensitivity of these components to initial eye position. In observations on 29 sites in nine cats, the vertical and horizontal components of saccades evoked from a given site were rarely influenced to the same degree by initial eye position. For most sites, the horizontal component was more sensitive than the vertical component. Sensitivities of vertical and horizontal components were lowest near the representations of the horizontal and vertical meridians, respectively, of the collicular retinotopic map, but otherwise exhibited no systematic retinotopic dependence. Estimates of component amplitudes for saccades evoked from the center of the oculomotor range also diverged significantly from those predicted from the retinotopic map. The results of this and previous studies indicate that electrical stimulation of the cat's superior colliculus cannot yield a unique oculomotor map or one that is in register everywhere with the sensory retinotopic map. Several features of these observations suggest that electrical stimulation of the colliculus produces faulty activation of a saccadic control system that computes target position with respect to the head and that small and large saccades are controlled differently.

  19. The safety of intraocular methotrexate in silicone-filled eyes.

    PubMed

    Hardwig, Paul W; Pulido, Jose S; Bakri, Sophie J

    2008-10-01

    Intraocular methotrexate has been safely used in eyes with primary CNS lymphoma (PCNSL), and in eyes with uveitis and proliferative diabetic retinopathy. Dosing in silicone-filled eyes was reduced from a standard 400 microg intravitreal injection due to concerns of toxicity. The present study reports the visual results of non-PCNSL, silicone-filled eyes treated with intravitreal methotrexate using cumulative dosages ranging from 200 microg to 1,200 microg. In this retrospective case series, all patients with silicone-filled eyes who received intraocular methotrexate were included. Patients were observed with serial ophthalmic examinations. Best-corrected visual acuity was measured by Snellen acuity. Pretreatment acuities were compared to those obtained at last follow-up. The cohort included 12 patients (13 eyes) with disease other than PCNSL. The cumulative dose of intraocular methotrexate in any one patient ranged from 200 microg to 1,200 microg. Mean follow-up was 9 months (median, 10 months; range, 2 weeks to 16 months). Best-corrected vision at last follow-up was either stable or improved from pretreatment acuity in 12 of 13 eyes. Preservation of acuity in 12 of 13 study eyes suggests that intravitreal methotrexate in a cumulative dose of up to 1,200 microg is safe in silicone-filled eyes.

  20. Treatment of primary Sjögren syndrome: a systematic review.

    PubMed

    Ramos-Casals, Manuel; Tzioufas, Athanasios G; Stone, John H; Sisó, Antoni; Bosch, Xavier

    2010-07-28

    A variety of topical and systemic drugs are available to treat primary Sjögren syndrome, although no evidence-based therapeutic guidelines are currently available. To summarize evidence on primary Sjögren syndrome drug therapy from randomized controlled trials. We searched MEDLINE and EMBASE for articles on drug therapy for primary Sjögren syndrome published between January 1, 1986, and April 30, 2010. Controlled trials of topical and systemic drugs including adult patients with primary Sjögren syndrome were selected as the primary information source. The search strategy yielded 37 trials. A placebo-controlled trial found significant improvement in the Schirmer and corneal staining scores, blurred vision, and artificial tear use in patients treated with topical ocular 0.05% cyclosporine. Three placebo-controlled trials found that pilocarpine was associated with improvements in dry mouth (61%-70% vs 24%-31% in the placebo group) and dry eye (42%-53% vs 26%). Two placebo-controlled trials found that cevimeline was associated with improvement in dry mouth (66%-76% vs 35%-37% in the placebo group) and dry eye (39%-72% vs 24%-30%). Small trials (<20 patients) found no significant improvement in sicca outcomes for oral prednisone or hydroxychloroquine and limited benefits for immunosuppressive agents (azathioprine and cyclosporine). A large trial found limited benefits for oral interferon alfa-2a. Two placebo-controlled trials of infliximab and etanercept did not achieve the primary outcome (a composite visual analog scale measuring joint pain, fatigue, and dryness); neither did 2 small trials (<30 patients) testing rituximab, although significant results were observed in some secondary outcomes and improvement compared with baseline. In primary Sjögren syndrome, evidence from controlled trials suggests benefits for pilocarpine and cevimeline for sicca features and topical cyclosporine for moderate or severe dry eye. Anti-tumor necrosis factor agents have not shown clinical efficacy, and larger controlled trials are needed to establish the efficacy of rituximab.

  1. [Prevalence of myopia and influencing factors among primary and middle school students in 6 provinces of China].

    PubMed

    Zhou, Jia; Ma, Yinghua; Ma, Jun; Zou, Zhiyong; Meng, Xiangkun; Tao, Fangbiao; Luo, Chunyan; Jing, Jin; Pan, Dehong; Luo, Jiayou; Zhang, Xin; Wang, Hong; Zhao, Haiping

    2016-01-01

    To understand the prevalence of myopia in primary and middle school students in 6 provinces and the possible influencing factors. Primary and middle school students were selected through multistage cluster sampling in 60 primary and middle schools in 6 provinces in China. The questionnaire survey and eyesight test were conducted among all the students selected according to the national student's physique and health survey protocol. Pearson chi-square test and binary multivariate logistic regression analysis were done to identify the influencing factors for myopia in students. The prevalence of myopia among primary and middle school students surveyed was 55.7%, the gender specific difference was statistically significant (59.7% for girls, 51.9% for boys) (P<0.01). The prevalence of myopia increased with age obviously. The prevalence was 35.8% in age group 6-8 years, 58.9% in age group 10-12 years, 73.4% in age group 13-15 years and 81.2% in age group 16-18 years, the differences were statistically significant (P<0.001). Single factor and multivariate analysis showed that parents' myopia, distance between computer screen and eyes, distance less than 30 cm between eyes and book while reading, distance less than 10 cm between chest and the table edge while studying, distance less than 3 cm between fingers and pen tip, sleep time, average outdoor activity time during last week, school sport activities in the afternoon, the size of television set at home, time spent on watching TV and playing computer were the influencing factors for myopia. The prevalence of myopia is till high in primary and middle school students. Myopia is associated with both genetic factors and individual eye health related behaviors.

  2. LOXL1 deficiency in the lamina cribrosa as candidate susceptibility factor for a pseudoexfoliation-specific risk of glaucoma.

    PubMed

    Schlötzer-Schrehardt, Ursula; Hammer, Christian M; Krysta, Anita W; Hofmann-Rummelt, Carmen; Pasutto, Francesca; Sasaki, Takako; Kruse, Friedrich E; Zenkel, Matthias

    2012-09-01

    To test the hypothesis that a primary disturbance in lysyl oxidase-like 1 (LOXL1) and elastin metabolism in the lamina cribrosa of eyes with pseudoexfoliation syndrome constitutes an independent risk factor for glaucoma development and progression. Observational, consecutive case series. Posterior segment tissues obtained from 37 donors with early and late stages of pseudoexfoliation syndrome without glaucoma, 37 normal age-matched control subjects, 5 eyes with pseudoexfoliation-associated open-angle glaucoma, and 5 eyes with primary open-angle glaucoma (POAG). Protein and mRNA expression of major elastic fiber components (elastin, fibrillin-1, fibulin-4), collagens (types I, III, and IV), and lysyl oxidase crosslinking enzymes (LOX, LOXL1, LOXL2) were assessed in situ by quantitative real-time polymerase chain reaction, (immuno)histochemistry, and light and electron microscopy. Lysyl oxidase-dependent elastin fiber assembly was assessed by primary optic nerve head astrocytes in vitro. Expression levels of elastic proteins, collagens, and lysyl oxidases in the lamina cribrosa. Lysyl oxidase-like 1 proved to be the major lysyl oxidase isoform in the normal lamina cribrosa in association with a complex elastic fiber network. Compared with normal and POAG specimens, lamina cribrosa tissues obtained from early and late stages of pseudoexfoliation syndrome without and with glaucoma consistently revealed a significant coordinated downregulation of LOXL1 and elastic fiber constituents on mRNA and protein level. In contrast, expression levels of collagens and other lysyl oxidase isoforms were not affected. Dysregulated expression of LOXL1 and elastic proteins was associated with pronounced (ultra)structural alterations of the elastic fiber network in the laminar beams of pseudoexfoliation syndrome eyes. Inhibition of LOXL1 interfered with elastic fiber assembly by optic nerve head astrocytes in vitro. The findings provide evidence for a pseudoexfoliation-specific elastinopathy of the lamina cribrosa resulting from a primary disturbance in LOXL1 regulation and elastic fiber homeostasis, possibly rendering pseudoexfoliation syndrome eyes more vulnerable to pressure-induced optic nerve damage and glaucoma development and progression. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. Relationship between progression of visual field defect and intraocular pressure in primary open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swedish interactive thresholding algorithm standard, C30-2 program). The progression of visual field defects was defined by a significantly negative value of the mean deviation slope at the final visual field test during the follow-up period. The relationships between the progression of visual field defects and IOP, as well as other clinical factors, were retrospectively analyzed. A total of 156 eyes of 156 patients were included in the analysis. Significant progression of visual field defects was observed in 70 eyes of 70 patients (44.9%), while no significant progression was evident in 86 eyes of 86 patients (55.1%). The eyes with visual field defect progression had significantly lower baseline IOP (P<0.05), as well as significantly lower IOP reduction rate (P<0.01). The standard deviation of IOP values during follow-up was significantly greater in the eyes with visual field defect progression than in eyes without (P<0.05). Reducing IOP is thought to be useful for Japanese POAG or NTG patients to suppress the progression of visual field defects. In NTG, IOP management should take into account not only achieving the target IOP, but also minimizing the fluctuation of IOP during follow-up period.

  4. Pathogenesis of persistent hyperplastic primary vitreous in mice lacking the arf tumor suppressor gene.

    PubMed

    Martin, Amy C; Thornton, J Derek; Liu, Jiewiu; Wang, XiaoFei; Zuo, Jian; Jablonski, Monica M; Chaum, Edward; Zindy, Frederique; Skapek, Stephen X

    2004-10-01

    Persistent hyperplastic primary vitreous (PHPV) is an idiopathic developmental eye disease associated with failed involution of the hyaloid vasculature. The present work addressed the pathogenesis of PHPV in a mouse model that replicates many aspects of the human disease. Ophthalmoscopic and histologic analyses documented pathologic processes in eyes of mice lacking the Arf gene compared with Ink4a-deficient and wild-type control animals. Immunohistochemical staining, in situ hybridization, and RT-PCR demonstrated the expression of relevant gene products. Arf gene expression was determined by in situ hybridization using wholemounts of wild-type mouse eyes and by immunofluorescence staining for green fluorescent protein (GFP) in Arf(+/GFP) heterozygous knock-in mouse eyes. Abnormalities in Arf(-/-) mice mimicked those found in patients with severe PHPV. The mice had microphthalmia; fibrovascular, retrolental tissue containing retinal pigment epithelial cells and remnants of the hyaloid vascular system; posterior lens capsule destruction with lens degeneration and opacity; and severe retinal dysplasia and detachment. Eyes of mice lacking the overlapping Ink4a gene were normal. Arf was selectively expressed in perivascular cells within the vitreous of the postnatal eye. Cells composing the retrolental mass in Arf(-/-) mice expressed the Arf promoter. The remnant hyaloid vessels expressed Flk-1. Its ligand, vascular endothelial growth factor (Vegf), was expressed in the retrolental tissue and the adjacent dysplastic neuroretina. Arf(-/-) mice have features that accurately mimic severe PHPV. In the HVS, Arf expression in perivascular cells may block their accumulation or repress Vegf expression to promote HVS involution and prevent PHPV.

  5. Pathogenesis of Persistent Hyperplastic Primary Vitreous in Mice Lacking the Arf Tumor Suppressor Gene

    PubMed Central

    Martin, Amy C.; Thornton, J. Derek; Liu, Jiewiu; Wang, XiaoFei; Zuo, Jian; Jablonski, Monica M.; Chaum, Edward; Zindy, Frederique; Skapek, Stephen X.

    2006-01-01

    Purpose Persistent hyperplastic primary vitreous (PHPV) is an idiopathic developmental eye disease associated with failed involution of the hyaloid vasculature. The present work addressed the pathogenesis of PHPV in a mouse model that replicates many aspects of the human disease. Methods Ophthalmoscopic and histologic analyses documented pathologic processes in eyes of mice lacking the Arf gene compared with Ink4a-deficient and wild-type control animals. Immunohistochemical staining, in situ hybridization, and RT-PCR demonstrated the expression of relevant gene products. Arf gene expression was determined by in situ hybridization using wholemounts of wild-type mouse eyes and by immunofluorescence staining for green fluores-cent protein (GFP) in Arf+/GFP heterozygous knock-in mouse eyes. Results Abnormalities in Arf−/− mice mimicked those found in patients with severe PHPV. The mice had microphthalmia; fibrovascular, retrolental tissue containing retinal pigment epithelial cells and remnants of the hyaloid vascular system; posterior lens capsule destruction with lens degeneration and opacity; and severe retinal dysplasia and detachment. Eyes of mice lacking the overlapping Ink4a gene were normal. Arf was selectively expressed in perivascular cells within the vitreous of the postnatal eye. Cells composing the retrolental mass in Arf−/− mice expressed the Arf promoter. The remnant hyaloid vessels expressed Flk-1. Its ligand, vascular endothelial growth factor (Vegf), was expressed in the retrolental tissue and the adjacent dysplastic neuroretina. Conclusions Arf−/− mice have features that accurately mimic severe PHPV. In the HVS, Arf expression in perivascular cells may block their accumulation or repress Vegf expression to promote HVS involution and prevent PHPV. PMID:15452040

  6. Instrument scanning and controlling: Using eye movement data to understand pilot behavior and strategies

    NASA Technical Reports Server (NTRS)

    Dick, A. O.

    1980-01-01

    Eye movement data and other parameters including instrument readings, aircraft state and position variables, and control maneuvers were recorded while pilots flew ILS simulations in a B 737. The experiment itself employed seven airline pilots, each of whom flew approximately 40 approach/landing sequences. The simulator was equipped with a night visual scene but the scene was fogged out down to approximately 60 meters (200 ft). The instrument scanning appeared to follow aircraft parameters not physical position of instruments. One important implication of the results is: pilots look for categories or packets of information. Control inputs were tabulated according to throttle, wheel position, column, and pitch trim changes. Three seconds of eye movements before and after the control input were then obtained. Analysis of the eye movement data for the controlling periods showed clear patterns. The results suggest a set of miniscan patterns which are used according to the specific details of the situation. A model is developed which integrates scanning and controlling. Differentiations are made between monitoring and controlling scans.

  7. Eye position affects flight altitude in visual approach to landing independent of level of expertise of pilot

    PubMed Central

    Camachon, Cyril; Montagne, Gilles

    2018-01-01

    The present study addresses the effect of the eye position in the cockpit on the flight altitude during the final approach to landing. Three groups of participants with different levels of expertise (novices, trainees, and certified pilots) were given a laptop with a flight simulator and they were asked to maintain a 3.71° glide slope while landing. Each participant performed 40 approaches to the runway. During 8 of the approaches, the point of view that the flight simulator used to compute the visual scene was slowly raised or lowered with 4 cm with respect to the cockpit, hence moving the projection of the visible part of the cockpit down or up in the visible scene in a hardly noticeable manner. The increases and decreases in the simulated eye height led to increases and decreases in the altitude of the approach trajectories, for all three groups of participants. On the basis of these results, it is argued that the eye position of pilots during visual approaches is a factor that contributes to the risk of black hole accidents. PMID:29795618

  8. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    PubMed

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  9. Gaze failure, drifting eye movements, and centripetal nystagmus in cerebellar disease.

    PubMed Central

    Leech, J; Gresty, M; Hess, K; Rudge, P

    1977-01-01

    Three abnormalities of eye movement in man are described which are indicative of cerebellar system disorder, namely, centripetally beating nystagmus, failure to maintain lateral gaze either in darkness or with eye closure, and slow drifting movements of the eyes in the absence of fixation. Similar eye movement signs follow cerebellectomy in the primate and the cat. These abnormalities of eye movement, together with other signs of cerebellar disease, such as rebound alternating, and gaze paretic nystagmus, are explained by the hypothesis that the cerebellum helps to maintain lateral gaze and that brain stem mechanisms which monitor gaze position generate compensatory biases in the absence of normal cerebellar function. PMID:603785

  10. Three-Dimensional Measurement Applied in Design Eye Point of Aircraft Cockpits.

    PubMed

    Wang, Yanyan; Guo, Xiaochao; Liu, Qingfeng; Xiao, Huajun; Bai, Yu

    2018-04-01

    Inappropriate design eye point (DEP) will lead to nonstandard sitting postures, including nonneutral head positions and other uncomfortable sitting postures, which are high risk factors for neck pain in fighter pilots exposed to high G forces. Therefore, application of a 3D measurement method to collect data regarding eye position while in the cruising sitting posture in the aircraft cockpit to guide the design eye point has been proposed. A total of 304 male fixed wing aircraft pilots were divided into two groups. Subgroup A (N = 48) were studied to define the cruising posture during flight. Subgroup B (N = 256) were studied with Romer 3D measurement equipment to locate the cruising eye position of the pilots in a simulated cockpit. The 3D data were compared to DEP data in the current standard cockpit. According to 3D measurement, the vertical distance from the cruising eye point to the neutral seat reference point was 759 mm, which is 36 mm lower than that of the Chinese standard DEP and also lower than the U.S. military standard. The horizontal distance was 131 mm, which is 24 mm shorter than that of the Chinese standard. The current DEP data cannot fulfill the needs of fighter pilots and should be amended according to the results of the 3D measurement so that pilots can acquire the optimal cruising posture in flight. This new method has the value of practical application to investigate cockpit ergonomics and the measurement data can guide DEP design.Wang Y, Guo X, Liu Q, Xiao H, Bai Y. Three-dimensional measurement applied in design eye point of aircraft cockpits. Aerosp Med Hum Perform. 2018; 89(4):371-376.

  11. A pilot study to evaluate incorporating eye care for children into reproductive and child health services in Dar-es-Salaam, Tanzania: a historical comparison study

    PubMed Central

    2014-01-01

    Background Many blinding eye conditions of childhood are preventable or treatable, particularly in developing countries. However, primary eye care (PEC) for children is poorly developed, leading to unnecessary visual loss. Activities for control by health workers entail interventions for systemic conditions (measles, vitamin A deficiency), identification and referral of children with sight threatening conditions and health education for caregivers. This pilot study evaluated integrating a package of activities to promote child eye health into Reproductive and Child Health (RCH) services in Dar-es-Salaam, Tanzania. Methods Design: historical comparison study. Fifteen Clinical Officers and 15 nurses in 15 randomly selected RCH clinics were trained in PEC for children in July 2010. They were given educational materials (poster and manual) and their supervisors were orientated. Knowledge and practices were assessed before and 3 weeks after training. One year later their knowledge and practices were compared with a different group of 15 Clinical Officers and 15 nurses who had not been trained. Results Before training staff had insufficient knowledge to identify, treat and refer children with eye diseases, even conjunctivitis. Some recommended harmful practices or did not know that cataract requires urgent referral. Eye examination, vitamin A supplementation of mothers after delivery and cleaning the eyes at birth with instillation of antibiotics (Crede’s prophylaxis) were not routine, and there were no eye-specific educational materials. Three weeks after training several clinics delivering babies started Crede’s prophylaxis, vitamin A supplementation of women after delivery increased from 83.7% to 100%, and all staff included eye conditions in health education sessions. At one year, trained staff were more likely to correctly describe, diagnose and treat conjunctivitis (z=2.34, p=0.04)(30%-vs-60.7%). Mystery mothers observed health education sessions in 7/10 RCH clinics with trained staff, five (71.4%) of which included eye conditions. Conclusions Primary eye care for children in Dar-es-Salaam is inadequate but training RCH staff can improve knowledge in the short term and change practices. Attendance by mothers and their children is high in RCH clinics, making them ideal for delivery of PEC. Ongoing supportive supervision is required to maintain knowledge and practices, as well as systems to track referrals. PMID:24932133

  12. Evaluation of a Web-Based Training in Smoking Cessation Counseling Targeting U.S. Eye-Care Professionals

    ERIC Educational Resources Information Center

    Asfar, Taghrid; Lee, David J.; Lam, Byron L.; Murchison, Ann P.; Mayro, Eileen L.; Owsley, Cynthia; McGwin, Gerald; Gower, Emily W.; Friedman, David S.; Saaddine, Jinan

    2018-01-01

    Background: Smoking causes blindness-related diseases. Eye-care providers are uniquely positioned to help their patients quit smoking. Aims: Using a pre-/postevaluation design, this study evaluated a web-based training in smoking cessation counseling targeting eye-care providers. Method: The training was developed based on the 3A1R protocol:…

  13. [Determination of cytomegalovirus IgG synthesis by the albumin correction in the aqueous humor of posner-schlossmann syndrome].

    PubMed

    Wang, X L; Wang, Z J; Tang, L; Cao, W W; Sun, X H

    2017-02-11

    Objective: To evaluate the usefulness of albumin correction in determination of cytomegalovirus IgG in the aqueous humor of Posner-Schlossman syndrome (PSS) patients. Methods: Cases series studies. Forty-two patients (26 men and 16 women) who were diagnosed as PSS were enrolled from Oct. 2009 to Oct. 2015 at the Eye and ENT Hospital. During the same period, 20 patients with primary open-angle glaucoma (POAG) and 30 patients with bacterial endophthalmitis or retinal necrosis were enrolled as negative control group and inflammatory disease control group, respectively. Aqueous humor and serum samples were assayed to detect CMV IgG by enzyme-linked immunosorbent assay (ELISA), and albumin by scattering immunonephelometry. CMV DNA in aqueous humor was assayed by polymerase chain reaction (PCR). The ratio which was calculated as the (aqueous humor CMV IgG/serum CMV IgG)/(aqueous humor concentration of albumin/serum albumin concentration) over 0.6 was considered as intraocular antibody formation. Performance of differentiating control eyes from eyes with CMV-positive PSS was evaluated by the receiver operating characteristic curve. The ANOVA test, Mann-Whitney test and Chi-square test were performed to compare the differences among groups. Results: The detectable rate of CMV IgG antibody in the aqueous humor was 76.2%, 100.0% and 10.0% in PSS, inflammatory disease control and POAG groups, respectively. The levels of CMV IgG antibody in the PSS groups were significantly higher than that of POAG groups ( Z= 4.23, P< 0.001).The positive rate corrected by the albumin was 71.4%, 3.3% and 0.0%.The corrected positive rate in PSS groups was significantly higher than that of the inflammatory disease control and POAG groups (χ(2)=30.38, P< 0.01; χ(2)= 24.89, P< 0.01), with a sensitivity of 75.0% and a specificity of 98.0%. The area under the curve for calibrated ratio was 0.942 (95% CI : 0.859 to 0.984) which was higher than that of CMV IgG ( Z= 6.19, P< 0.001).The corrected positive rate of CMV IgG antibody (71.4%) was higher than that of CMV DNA (47.6%, χ(2)=4.003, P= 0.045). Conclusions: CMV IgG antibody ratio which was corrected by aqueous humor and serum albumin could effectively improve aqueous antibody specificity in PSS patients. Furthermore, CMV IgG antibody ratio combined with PCR could improve the sensitivity of CMV detection. All of which help clarify the CMV infection in PSS in CMV DNA negative eyes. (Chin J Ophthalmol, 2017, 53: 104-108) .

  14. Retrograde air escape via the nasolacrimal system: a previously unrecognized complication of continuous positive airway pressure in the management of obstructive sleep apnea.

    PubMed

    Singh, Narinder Pal; Walker, Robbie James Eades; Cowan, Fiona; Davidson, Arthur Craig; Roberts, David Newton

    2014-05-01

    Continuous positive airway pressure (CPAP) is the gold standard treatment for moderate to severe obstructive sleep apnoea (OSA). Eye-related side effects of CPAP are commonly attributed to a poorly sealed mask, allowing leaked air to blow over the eye. We present 3 cases where attended polysomnography (A-PSG) demonstrated CPAP-associated retrograde air escape via the nasolacrimal system (CRANS) in the absence of any mask leaks. Symptoms included dry eye, epiphora, air escape from the medial canthus, and eyelid flutter. Symptoms were controlled with a variety of surgical and nonsurgical techniques. CRANS represents a previously undescribed clinical entity. CRANS may be responsible for some CPAP-related eye side effects and possibly for rarer secondary eye complications, including conjunctivitis and corneal ulceration. CRANS should be suspected in any patient on CPAP complaining of eye symptoms. CRANS may be diagnosed through careful observation during A-PSG and confirmed by performing a "saline bubble test." Management options include nonsurgical (mask alternatives, humidification, nasopharyngeal airway) and surgical techniques (nasal airway surgery, inferior turbinate out-fracture and adhesion, injection of bulking agent around Hasner's valve).

  15. Axis of Eye Rotation Changes with Head-Pitch Orientation during Head Impulses about Earth-Vertical

    PubMed Central

    Schubert, Michael C.; Clendaniel, Richard A.; Carey, John P.; Della Santina, Charles C.; Minor, Lloyd B.; Zee, David S.

    2006-01-01

    The goal of this study was to assess how the axis of head rotation, Listing's law, and eye position influence the axis of eye rotation during brief, rapid head rotations. We specifically asked how the axis of eye rotation during the initial angular vestibuloocular reflex (VOR) changed when the pitch orientation of the head relative to Earth-vertical was varied, but the initial position of the eye in the orbit and the orientation of Listing's plane with respect to the head were fixed. We measured three-dimensional eye and head rotation axes in eight normal humans using the search coil technique during head-and-trunk (whole-body) and head-on-trunk (head-only) “impulses” about an Earth-vertical axis. The head was initially oriented at one of five pitch angles (30° nose down, 15° nose down, 0°, 15° nose up, 30° nose up). The fixation target was always aligned with the nasooccipital axis. Whole-body impulses were passive, unpredictable, manual, rotations with peak-amplitude of ∼20°, peak-velocity of ∼80°/s, and peak-acceleration of ∼1000°/s2. Head-only impulses were also passive, unpredictable, manual, rotations with peak-amplitude of ∼20°, peak-velocity of ∼150°/s, and peak-acceleration of ∼3000°/s2. During whole-body impulses, the axis of eye rotation tilted in the same direction, and by an amount proportional (0.51 ± 0.09), to the starting pitch head orientation (P < 0.05). This proportionality constant decreased slightly to 0.39 ± 0.08 (P < 0.05) during head-only impulses. Using the head-only impulse data, with the head pitched up, we showed that only 50% of the tilt in the axis of eye rotation could be predicted from vectorial summation of the gains (eye velocity/head velocity) obtained for rotations about the pure yaw and roll head axes. Thus, even when the orientation of Listing's plane and eye position in the orbit are fixed, the axis of eye rotation during the VOR reflects a compromise between the requirements of Listing's law and a perfectly compensatory VOR. PMID:16552499

  16. Bilateral ocular abnormalities in a wild stranded harp seal (Phoca groenlandica) suggestive of anterior segment dysgenesis and persistent hyperplastic primary vitreous.

    PubMed

    Erlacher-Reid, Claire; Colitz, Carmen M H; Abrams, Ken; Smith, Ainsley; Tuttle, Allison D

    2011-06-01

    A male yearling harp seal (Phoca groenlandica) stranded and was brought to Mystic Aquarium & Institute for Exploration's Seal Rescue and Rehabilitation Center. The seal presented with a bilateral pendular vertical nystagmus, negative menace response, and a positive palpebral response. Ophthalmological examination by slit lamp biomicroscopy revealed perilimbal corneal edema, excessive iridal surface structures, pupils that appeared to be shaped improperly (dyscoria), and suspected cataracts. Attempts to dilate the pupils with both dark-lighted conditions and repeated dosages of 10% phenylephrine and 1% atropine ophthalmic solution in each eye (OU) were unsuccessful. Ocular ultrasonography findings suggested bilateral cataracts with flattened anterior-posterior (A-P) diameter and possible persistent hyperplastic primary vitreous. It is possible that these structural congenital abnormalities could produce further ocular complications for this seal including uveitis, secondary glaucoma, retinal detachment, and/or vitreal hemorrhage in the future. This case demonstrates the importance of a thorough ophthalmological examination in stranded wild animals, especially if their symptoms appear neurological.

  17. [Ultrasonographic findings in ocular toxocariasis].

    PubMed

    Morais, Fábio Barreto; Maciel, Ana Lúcia; Arantes, Tiago Eugênio Farias e; Muccioli, Cristina; Allemann, Norma

    2012-01-01

    To evaluate ophthalmic ultrasound findings in the three presentation forms of ocular toxocariasis (peripheral or posterior pole granulomas and chronic endophthalmitis), in patients with confirmed diagnosis of ocular toxocariasis. 11 patients (11 eyes) with clinical and confirmed diagnosis of active ocular toxocariasis, presented positive ELISA test, were analyzed, prospectively, in the study. The patients were submitted to an ocular ultrasound examination (10-MHz transducer, contact technique). In the series of 11 patients, mean age was 7.9 years-old (range from 2 to 17 y), 73% male, referring previous contact with dogs (91%), and with the soil (50%), no referral of appetite perversion. In the analyses of compromised eyes (11 eyes), the ophthalmoscopic examination revealed the following distribution of the 3 forms of ocular toxocariasis: 7 cases (63.6%), posterior pole granuloma; 1 (9.1%), chronic endophthalmitis; 2 (18.2%), peripheral granuloma; and 1 (9.1%), posterior pole granuloma associated with chronic endophthalmitis. Visual acuity impairment: no light perception (3 eyes, 27.3%); hand motion (4 eyes, 36.4%); counting fingers at 10 cm (1 eye, 9.1%); 20/200 (1 eye, 9.1%); 20/70 (1 eye, 9.1%); undefined (1 eye, 9.1%). Serology was positive to Toxocara canis (ELISA test) in 100% of the cases. Ophthalmoscopy was difficult or impossible in 64% of the cases due to the media opacity. Ultrasound findings noted were vitreous membranes with retinal attachment (100%); parietal lesions (granulomas) with high (80%) or medium (20%) reflectivity. The most consistent ultrasound finding in the eye with toxocariasis was a high-reflectivity retinal mass, located in posterior pole or periphery, which may be calcified, and which has as main characteristic the adherence of vitreous membranes. In addition to clinical history, systemic evaluation and serology, the ultrasound can help in the diagnosis of ocular toxocariasis, especially in media opacities.

  18. Eye Growth in Term- And Preterm-Born Eyes Modeled From Magnetic Resonance Images

    PubMed Central

    Munro, Robert J.; Fulton, Anne B.; Chui, Toco Y. P.; Moskowitz, Anne; Ramamirtham, Ramkumar; Hansen, Ronald M.; Prabhu, Sanjay P.; Akula, James D.

    2015-01-01

    Purpose. We generated a model of eye growth and tested it against an eye known to develop abnormally, one with a history of retinopathy of prematurity (ROP). Methods. We reviewed extant magnetic resonance images (MRIs) from term and preterm-born patients for suitable images (n = 129). We binned subjects for analysis based upon postmenstrual age at birth (in weeks) and ROP history (“Term” ≥ 37, “Premature” ≤ 32 with no ROP, “ROP” ≤ 32 with ROP). We measured the axial positions and curvatures of the cornea, anterior and posterior lens, and inner retinal surface. We fit anterior chamber depth (ACD), posterior segment depth (PSD), axial length (AL), and corneal and lenticular curvatures with logistic growth curves that we then evaluated for significant differences. We also measured the length of rays from the centroid to the surface of the eye at 5° intervals, and described the length versus age relationship of each ray, Lray(x), using the same logistic growth curve. We determined the rate of ray elongation, Eray(x), from Lray dy/dx. Then, we estimated the scleral growth that accounted for Eray(x), G(x), at every age and position. Results. Relative to Term, development of ACD, PSD, AL, and corneal and lenticular curvatures was delayed in ROP eyes, but not Premature eyes. In Term infants, G(x) was fast and predominantly equatorial; in age-matched ROP eyes, maximal G(x) was offset by approximately 90°. Conclusions. We produced a model of normal eye growth in term-born subjects. Relative to normal, the ROP eye is characterized by delayed, abnormal growth. PMID:26024095

  19. Differences in neural crest sensitivity to ethanol account for the infrequency of anterior segment defects in the eye compared with craniofacial anomalies in a zebrafish model of fetal alcohol syndrome.

    PubMed

    Eason, Jessica; Williams, Antionette L; Chawla, Bahaar; Apsey, Christian; Bohnsack, Brenda L

    2017-09-01

    Ethanol (ETOH) exposure during pregnancy is associated with craniofacial and neurologic abnormalities, but infrequently disrupts the anterior segment of the eye. In these studies, we used zebrafish to investigate differences in the teratogenic effect of ETOH on craniofacial, periocular, and ocular neural crest. Zebrafish eye and neural crest development was analyzed by means of live imaging, TUNEL (terminal deoxynucleotidyl transferase dUTP nick end labeling) assay, immunostaining, detection of reactive oxygen species, and in situ hybridization. Our studies demonstrated that foxd3-positive neural crest cells in the periocular mesenchyme and developing eye were less sensitive to ETOH than sox10-positive craniofacial neural crest cells that form the pharyngeal arches and jaw. ETOH increased apoptosis in the retina, but did not affect survival of periocular and ocular neural crest cells. ETOH also did not increase reactive oxygen species within the eye. In contrast, ETOH increased ventral neural crest apoptosis and reactive oxygen species production in the facial mesenchyme. In the eye and craniofacial region, sod2 showed high levels of expression in the anterior segment and in the setting of Sod2 knockdown, low levels of ETOH decreased migration of foxd3-positive neural crest cells into the developing eye. However, ETOH had minimal effect on the periocular and ocular expression of transcription factors (pitx2 and foxc1) that regulate anterior segment development. Neural crest cells contributing to the anterior segment of the eye exhibit increased ability to withstand ETOH-induced oxidative stress and apoptosis. These studies explain the rarity of anterior segment dysgenesis despite the frequent craniofacial abnormalities in fetal alcohol syndrome. Birth Defects Research 109:1212-1227, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  20. Online Learners’ Reading Ability Detection Based on Eye-Tracking Sensors

    PubMed Central

    Zhan, Zehui; Zhang, Lei; Mei, Hu; Fong, Patrick S. W.

    2016-01-01

    The detection of university online learners’ reading ability is generally problematic and time-consuming. Thus the eye-tracking sensors have been employed in this study, to record temporal and spatial human eye movements. Learners’ pupils, blinks, fixation, saccade, and regression are recognized as primary indicators for detecting reading abilities. A computational model is established according to the empirical eye-tracking data, and applying the multi-feature regularization machine learning mechanism based on a Low-rank Constraint. The model presents good generalization ability with an error of only 4.9% when randomly running 100 times. It has obvious advantages in saving time and improving precision, with only 20 min of testing required for prediction of an individual learner’s reading ability. PMID:27626418

Top