Prisms with total internal reflection as solar reflectors
Rabl, Arnulf; Rabl, Veronika
1978-01-01
An improved reflective wall for radiant energy collection and concentration devices is provided. The wall is comprised of a plurality of prisms whose frontal faces are adjacent and which reflect the desired radiation by total internal reflection.
Precise optical observation of 0.5-GPa shock waves in condensed materials
NASA Astrophysics Data System (ADS)
Nagayama, Kunihito; Mori, Yasuhito
1999-06-01
Precision optical observation method was developed to study impact-generated high-pressure shock waves in condensed materials. The present method makes it possible to sensitively detect the shock waves of the relatively low shock stress around 0.5 GPa. The principle of the present method is based on the use of total internal reflection by triangular prisms placed on the free surface of a target assembly. When a plane shock wave arrives at the free surface, the light reflected from the prisms extinguishes instantaneously. The reason is that the total internal reflection changes to the reflection depending on micron roughness of the free surface after the shock arrival. The shock arrival at the bottom face of the prisms can be detected here by two kinds of methods, i.e., a photographic method and a gauge method. The photographic method is an inclined prism method of using a high-speed streak camera. The shock velocity and the shock tilt angle can be estimated accurately from an obtained streak photograph. While in the gauge method, an in-material PVDF stress gauge is combined with an optical prism-pin. The PVDF gauge records electrically the stress profile behind the shockwave front, and the Hugoniot data can be precisely measured by combining the prism pin with the PVDF gauge.
Design of an fMRI-compatible optical touch stripe based on frustrated total internal reflection.
Jarrahi, Behnaz; Wanek, Johann
2014-01-01
Previously we developed a low-cost, multi-configurable handheld response system, using a reflective-type intensity modulated fiber-optic sensor (FOS) to accurately gather participants' behavioral responses during functional magnetic resonance imaging (fMRI). Inspired by the popularity and omnipresence of the fingertip-based touch sensing user interface devices, in this paper we present the design of a prototype fMRI-compatible optical touch stripe (OTS) as an alternative configuration. The prototype device takes advantage of a proven frustrated total internal reflection (FTIR) technique. By using a custom-built wedge-shaped optically transparent acrylic prism as an optical waveguide, and a plano-concave lens to provide the required light beam profile, the position of a fingertip touching the surface of the wedge prism can be determined from the deflected light beams that become trapped within the prism by total internal reflection. To achieve maximum sensitivity, the optical design of the wedge prism and lens were optimized through a series of light beam simulations using WinLens 3D Basic software suite. Furthermore, OTS performance and MRI-compatibility were assessed on a 3.0 Tesla MRI scanner running echo planar imaging (EPI) sequences. The results show that the OTS can detect a touch signal at high spatial resolution (about 0.5 cm), and is well suited for use within the MRI environment with average time-variant signal-to-noise ratio (tSNR) loss < 3%.
Zhang, Jiwei; Di, Jianglei; Li, Ying; Xi, Teli; Zhao, Jianlin
2015-10-19
We present a method for dynamically measuring the refractive index distribution in a large range based on the combination of digital holographic interferometry and total internal reflection. A series of holograms, carrying the index information of mixed liquids adhered on a total reflection prism surface, are recorded with CCD during the diffusion process. Phase shift differences of the reflected light are reconstructed exploiting the principle of double-exposure holographic interferometry. According to the relationship between the reflection phase shift difference and the liquid index, two dimensional index distributions can be directly figured out, assuming that the index of air near the prism surface is constant. The proposed method can also be applied to measure the index of solid media and monitor the index variation during some chemical reaction processes.
Wang, Shinn-Fwu; Chiu, Ming-Hung; Chen, Wei-Wu; Kao, Fu-Hsi; Chang, Rong-Seng
2009-05-01
A small-displacement sensing system based on multiple total internal reflections in heterodyne interferometry is proposed. In this paper, a small displacement can be obtained only by measuring the variation in phase difference between s- and p-polarization states for the total internal reflection effect. In order to improve the sensitivity, we increase the number of total internal reflections by using a parallelogram prism. The theoretical resolution of the method is better than 0.417 nm. The method has some merits, e.g., high resolution, high sensitivity, and real-time measurement. Also, its feasibility is demonstrated.
Xie, Peng; Lin, Huichuan; Liu, Yong; Li, Baojun
2014-10-20
We present a waveguide coupling approach for planar waveguide solar concentrator. In this approach, total internal reflection (TIR)-based symmetric air prisms are used as couplers to increase the coupler reflectivity and to maximize the optical efficiency. The proposed concentrator consists of a line focusing cylindrical lens array over a planar waveguide. The TIR-based couplers are located at the focal line of each lens to couple the focused sunlight into the waveguide. The optical system was modeled and simulated with a commercial ray tracing software (Zemax). Results show that the system used with optimized TIR-based couplers can achieve 70% optical efficiency at 50 × geometrical concentration ratio, resulting in a flux concentration ratio of 35 without additional secondary concentrator. An acceptance angle of ± 7.5° is achieved in the x-z plane due to the use of cylindrical lens array as the primary concentrator.
Khanfar, H K; Azzam, R M A
2009-09-20
An iterative procedure for the design of a polarizing beam splitter (PBS) that uses a form-birefringent, subwavelength-structured, one-dimensional photonic-crystal layer (SWS 1-D PCL) embedded in a high-index cubical prism is presented. The PBS is based on index matching and total transmission for the p polarization and total internal reflection for the s polarization at the prism-PCL interface at 45 degrees angle of incidence. A high extinction ratio in reflection (>50 dB) over the 4-12 microm IR spectral range is achieved using a SWS 1-D PCL of ZnTe embedded in a ZnS cube within an external field of view of +/-6.6 degrees and in the presence of grating filling factor errors of up to +/-10%. Comparable results, but with wider field of view, are also obtained with a Ge PCL embedded in a Si prism.
Two-pass-internal second-harmonic generation using a prism coupler.
NASA Technical Reports Server (NTRS)
Gonzalez, D. G.; Nieh, S. T. K.; Steier, W. H.
1973-01-01
A dispersive quartz prism is used to couple the total second harmonic generated in both directions by an internal cavity frequency doubler. The study shows that the dispersion of air and mirror reflection phase shifts can be compensated for by a slight nonphase match condition in the doubler.
Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics
ERIC Educational Resources Information Center
Planinsic, Gorazd; Gojkosek, Mihael
2011-01-01
Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…
Prism fingerprint sensor that uses a holographic optical element
NASA Astrophysics Data System (ADS)
Bahuguna, R. D.; Corboline, Tom
1996-09-01
A prism fingerprint sensor is described that uses a holographic grating glued to a right-angled prism. A light source normally illuminates the hypotenuse side of the prism with the finger pressed against the grating. The ridges and valleys of the finger are sensed on the basis of the principle of total internal reflection. The grating is used essentially to correct the distortion usually present with prism sensors. The quality of the fingerprint is very good: the pores on the ridges can be seen.
An improved prism for use in laser resonators
NASA Astrophysics Data System (ADS)
Richards, J.
1981-08-01
The use of compound total internal reflection prisms rather than Porro prisms in polarisation coupled lasers is proposed. Performance advantages resulting from the use of these prisms include higher output without the need to bias the Pockels cell, ability to give a larger range of output coupling and independence of performance on the refractive index of the prism. In conventional Q-switched lasers the use of the prism at the Pockels cell end of the resonator instead of the usual 100% reflecting mirror also leads to some advantages including better hold-off, elimination of the need to bias the Pockels cell and insensitivity in one plane to angular misalignment.
NASA Astrophysics Data System (ADS)
Ehrhart, Matthias; Lienhart, Werner
2017-09-01
The importance of automated prism tracking is increasingly triggered by the rising automation of total station measurements in machine control, monitoring and one-person operation. In this article we summarize and explain the different techniques that are used to coarsely search a prism, to precisely aim at a prism, and to identify whether the correct prism is tracked. Along with the state-of-the-art review, we discuss and experimentally evaluate possible improvements based on the image data of an additional wide-angle camera which is available for many total stations today. In cases in which the total station's fine aiming module loses the prism, the tracked object may still be visible to the wide-angle camera because of its larger field of view. The theodolite angles towards the target can then be derived from its image coordinates which facilitates a fast reacquisition of the prism. In experimental measurements we demonstrate that our image-based approach for the coarse target search is 4 to 10-times faster than conventional approaches.
NASA Astrophysics Data System (ADS)
Ribeiro, Jair Lúcio Prados
2018-01-01
We only became aware of the existence of bed prism spectacles when a student brought them to the classroom and asked us about how they work. The device proved to be a fertile source of curiosity among the students, and, to be properly understood, it required us to develop a comparison between reflection in a typical mirror and total internal reflection in a prism. In this article we explain the physics behind this unfamiliar device, supported by geometrical optics principles.
Optimum Solar Conversion Cell Configurations
NASA Technical Reports Server (NTRS)
Chen, Bin (Inventor)
2015-01-01
Methods for maximizing a fraction of light energy absorbed in each of three classes of light concentrators (rectangular parallelepipeds, paraboloids and prisms) by choice of incident angle of radiation and of one or more geometrical or physical parameters (absorber thickness, paraboloid dimensions, location of paraboloid focus, prism angles, concentrator material, cladding, prism angles, etc.). Alternatively, the light energy absorbed plus the light energy that escapes through non-total internal reflection within the light concentrator can be minimized.
NASA Technical Reports Server (NTRS)
Harper, L. L. (Inventor)
1983-01-01
An optical resonator cavity configuration has a unitary mirror with oppositely directed convex and concave reflective surfaces disposed into one fold and concertedly reversing both ends of a beam propagating from a laser rod disposed between two total internal reflection prisms. The optical components are rigidly positioned with perpendicularly crossed virtual rooflines by a compact optical bed. The rooflines of the internal reflection prisms, are arranged perpendicularly to the axis of the laser beam and to the optical axes of the optical resonator components.
Total internal reflection laser tools and methods
Zediker, Mark S.; Faircloth, Brian O.; Kolachalam, Sharath K.; Grubb, Daryl L.
2016-02-02
There is provided high power laser tools and laser heads that utilize total internal reflection ("TIR") structures to direct the laser beam along a laser beam path within the TIR structure. The TIR structures may be a TIR prism having its hypotenuse as a TIR surface.
Nonpolarizing beam splitter designed by frustrated total internal reflection inside a glass cube.
Xu, Xueke; Shao, Jianda; Fan, Zhengxiu
2006-06-20
A method for the design of an all-dielectric nonpolarizing prism beam splitter utilizing the principle of frustrated total internal reflection is reported. The nonpolarizing condition for a prism beam splitter is discussed, and some single layer design examples are elaborated. The concept can be applied to a wide range of wavelengths and arbitrary transmittance values, and with the help of a computer design program examples of 400-700 nm, T(p)=T(s)=0.5+/-0.01, with incident angles of 45 degrees and 62 degrees are given. In addition, the sensitivity and application of the design are also discussed.
Graphene-based magnetless converter of terahertz wave polarization
NASA Astrophysics Data System (ADS)
Melnikova, Veronica S.; Polischuk, Olga V.; Popov, Vyacheslav V.
2016-04-01
The polarization conversion of terahertz radiation by the periodic array of graphene nanoribbons located at the surface of a high-refractive-index dielectric substrate (terahertz prism) is studied theoretically. Giant polarization conversion at the plasmon resonance frequencies takes place without applying external DC magnetic field. It is shown that the total polarization conversion can be reached at the total internal reflection of THz wave from the periodic array of graphene nanoribbons even at room temperature.
Single-Frequency Nd:YAG Ring Lasers with Corner Cube Prism
NASA Astrophysics Data System (ADS)
Wu, Ke-Ying; Yang, Su-Hui; Zhao, Chang-Ming; Wei, Guang-Hui
2000-10-01
We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single-frequency generating power. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix.
NASA Astrophysics Data System (ADS)
Liu, Xudong; Chen, Xuequan; Parrott, Edward P. J.; Han, Chunrui; Humbert, Georges; Crunteanu, Aurelian; Pickwell-MacPherson, Emma
2018-05-01
Active broadband terahertz (THz) polarization manipulation devices are challenging to realize, but also of great demand in broadband terahertz systems. Vanadium dioxide (VO2) shows a promising phase transition for active control of THz waves and provides broadband polarization characteristics when integrated within grating-type structures. We creatively combine a VO2-based grating structure with a total internal reflection (TIR) geometry providing a novel interaction mechanism between the electromagnetic waves and the device, to realize a powerful active broadband THz polarization-controlling device. The device is based on a Si-substrate coated with a VO2 layer and a metal grating structure on top, attached to a prism for generating the TIR condition on the Si-VO2-grating interface. The grating is connected to electrodes for electrically switching the VO2 between its insulating and conducting phases. By properly selecting the incident angle of the THz waves, the grating direction, and the incident polarization state, we first achieved a broadband intensity modulator under a fused silica prism with an average modulation depth of 99.75% in the 0.2-1.1 THz region. Additionally, we realized an active ultra-broadband quarter-wave converter under a Si prism that can be switched between a 45° linear rotator and a quarter wave converter in the 0.8-1.5 THz region. This is the first demonstration of an active quarter-wave converter with ultra-broad bandwidth performance. Our work shows a highly flexible and multifunctional polarization-controlling device for broadband THz applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polischuk, O. V., E-mail: polischuk.sfire@mail.ru; Melnikova, V. S.; Popov, V. V., E-mail: popov-slava@yahoo.co.uk
2016-11-15
The terahertz absorption spectrum in a periodic array of graphene nanoribbons located on the surface of a dielectric substrate with a high refractive index (terahertz prism) is studied theoretically. The total absorption of terahertz radiation is shown to occur in the regime of total internal reflection of the terahertz wave from the periodic array of graphene nanoribbons, at the frequencies of plasma oscillations in graphene, in a wide range of incidence angles of the external terahertz wave even at room temperature.
Postural stability changes during large vertical diplopia induced by prism wear in normal subjects.
Matsuo, Toshihiko; Yamasaki, Hanako; Yasuhara, Hirotaka; Hasebe, Kayoko
2013-01-01
To test the effect of double vision on postural stability, we measured postural stability by electric stabilometry before prism-wearing and immediately, 15, 30, and 60min after continuous prism-wearing with 6 prism diopters in total (a 3-prism-diopter prism placed with the base up in front of one eye and with the base down in front of the other eye) in 20 normal adult individuals with their eyes open or closed. Changes in stabilometric parameters in the time course of 60min were analyzed statistically by repeated-measure analysis of variance. When subjectsセ eyes were closed, the total linear length (cm) and the unit-time length (cm/sec) of the sway path were significantly shortened during the 60-minute prism-wearing (p<0.05). No significant change was noted in any stabilometric parameters obtained with the eyes open during the time course. In conclusion, postural stability did not change with the eyes open in the condition of large vertical diplopia, induced by prism-wearing for 60min, while the stability became better when measured with the eyes closed. A postural control mechanism other than that derived from visual input might be reinforced under abnormal visual input such as non-fusionable diplopia.
Maintaining a stationary laser footprint during angular scan in internal-reflection experiments.
Fontana, Eduardo; Cavalcanti, Gustavo Oliveira
2013-11-10
In internal-reflection metrology using prisms, the prism is usually mounted on a rotation/translation stage to enable adjusting angle and location of the laser footprint on the surface. If a visual inspection method is used to find the laser footprint, the task becomes impossible if invisible radiation in the near infrared is employed. In addition, it may be desirable to perform angular scan experiments with a stationary footprint on the surface during scans, or even to automatically probe specific points on an extended prism face for predetermined incidence angles. In this paper, a formulation is developed to determine the required translation along the prism face to allow maintaining the laser footprint stationary under a given rotation. A web-based app developed under the scope of this work demonstrates the applicability of the approach for silica, BK7 and SF2 glasses, in the wavelength range from 500 to 1500 nm and for an arbitrary geometry of the glass prism.
Thio, Si Kuan; Jiang, Dongyue; Park, Sung-Yong
2018-06-12
Optofluidics is an emerging research field that combines the two disciplines of microfluidics and optics. By using microfluidic technologies for light control, optofluidic devices can offer several advantages over solid-type optical components, including optical-grade smoothness at the fluidic interface and a high degree of optical tunability without bulky and complex mechanical moving parts. These features have made optofluidic devices more versatile and reconfigurable to improve their optical performances. In this paper, we present a novel optofluidic sunlight manipulation technology for solar indoor lighting using the electrowetting principle. Rooftop sunlight is collected by a solar concentrator and guided to individual rooms along an optical fiber (waveguide) on the bottom of which tunable liquid prisms are linearly integrated. In the light-off mode, electrowetting controls the apex angle of the prisms to be φ = 0°. Under this condition, incoming sunlight experiences total internal reflection and thus keeps propagating along the optical fiber without leaking to the prism bottom for indoor lighting. In contrast, when liquid prisms are controlled to have the angle at φ > 0°, incoming sunlight is partially transmitted to the bottom surface of the arrayed prisms to contribute to interior illumination. Simulation studies validate that our electrowetting-driven solar indoor lighting (e-SIL) system is capable of variably tuning the lighting power from 0% to 98.6% of the input solar power by controlling the prism angle and varying the refractive index of prism materials. For experimental studies, we fabricated an array of 5 prisms filled with silicone oil and water. Using a fiber illuminator as a white light source that includes visible light with various incident angles, we have demonstrated two important lighting functions, (1) light on/off and (2) illumination power control. Lighting performance can be further enhanced by lowering the aspect ratio of the prism as well as increasing the number of prisms. The e-SIL technology based on tunable liquid prisms offers a new approach towards sustainable buildings that are able to reduce their electricity usage as well as provide a healthy and comfortable indoor environment under illumination of natural sunlight.
The Program for Regional and International Shorebird Monitoring (PRISM)
Jonathan Bart; Brad Andres; Stephen Brown; Garry Donaldson; Brian Harrington; Vicky Johnston; Stephanie Jones; Guy Morrison; Susan Skagen
2005-01-01
This report describes the “Program for Regional and International Shorebird Monitoring” (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird...
NASA Astrophysics Data System (ADS)
Wilson, T.; Kasper, E.; Oehme, M.; Schulze, J.; Korolev, K.
2014-11-01
We report on the direct excitation of 246 GHz longitudinal acoustic phonons in silicon doping superlattices by the resonant absorption of nanosecond-pulsed far-infrared laser radiation of the same frequency. A longitudinally polarized evanescent laser light field is coupled to the superlattice through a germanium prism providing total internal reflection at the superlattice interface. The ballistic phonon signal is detected by a superconducting aluminum bolometer. The sample is immersed in low-temperature liquid helium.
Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji
2016-02-01
A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.
Single-frequency Nd:YAG ring lasers with corner cube prism
NASA Astrophysics Data System (ADS)
Wu, Ke Ying; Yang, Su Hui; Zhao, Chang Ming; Wei, Guang Hui
2000-04-01
Kane and Byer reported the first monolithic non-planar miniature ring lasers in 1985. An intrinsic optical diode enforces unidirectional and hence single-frequency oscillation of this device. It has the advantages of compactness, reliability and high efficiency. We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single- frequency generating. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix. The results of our initial experiment are given in the paper.
NASA Astrophysics Data System (ADS)
Andreev, R. B.; Butylkin, V. S.; Evtiushkin, V. A.; Fisher, P. S.; Khabarov, V. V.
1983-03-01
The threshold of stimulated Raman scattering was lowered by filling an optical delay line with hydrogen. Pumping was by a tunable neodymium laser. Lens-prism combinations were used as phase correctors in the delay line. The dependences of the energy of the Stokes component on the pump energy determined experimentally for different numbers of transits through the delay line were compared with the results of a calculation allowing for the losses in the components of this line. When the frequency conversion was by a factor of at least 2 and the tuning range was wide (tens of percent), the optimal performance was obtained from the optical delay line when total-internal-reflection prisms and lenses were combined in a single component and oriented at the Brewster angle.
NASA Astrophysics Data System (ADS)
Andreev, R. B.; Butylkin, V. S.; Evtyushkin, V. A.; Fisher, P. S.; Khabarov, V. V.
1983-03-01
The threshold of stimulated Raman scattering was lowered by filling an optical delay line with hydrogen. Pumping was by a tunable neodymium laser. Lens-prism combinations were used as phase correctors in the delay line. The dependences of the energy of the Stokes component on the pump energy determined experimentally for different numbers of transits through the delay line were compared with the results of a calculation allowing for the losses in the components of this line. When the frequency conversion was by a factor of at least 2 and the tuning range was wide (tens of percent), the optimal performance was obtained from the optical delay line when total-internal-reflection prisms and lenses were combined in a single component and oriented at the Brewster angle.
An optically passive method that doubles the rate of 2-Ghz timing fiducials
NASA Astrophysics Data System (ADS)
Boni, R.; Kendrick, J.; Sorce, C.
2017-08-01
Solid-state optical comb-pulse generators provide a convenient and accurate method to include timing fiducials in a streak camera image for time base correction. Commercially available vertical-cavity surface-emitting lasers (VCSEL's) emitting in the visible currently in use can be modulated up to 2 GHz. An optically passive method is presented to interleave a time-delayed path of the 2-GHz comb with itself, producing a 4-GHz comb. This technique can be applied to VCSEL's with higher modulation rates. A fiber-delivered, randomly polarized 2-GHz VCSEL comb is polarization split into s-polarization and p-polarization paths. One path is time delayed relative to the other by twice the 2-GHz rate with +/-1-ps accuracy; the two paths then recombine at the fiber-coupled output. High throughput (>=90%) is achieved by carefully using polarization beam-splitting cubes, a total internal reflection beam-path-steering prism, and antireflection coatings. The glass path-length delay block and turning prism are optically contacted together. The beam polarizer cubes that split and recombine the paths are precision aligned and permanently cemented into place. We expect the palm-sized, inline fiber-coupled, comb-rate-doubling device to maintain its internal alignment indefinitely.
NASA Astrophysics Data System (ADS)
Dowsett, H. J.; Dolan, A. M.; Rowley, D. B.; Moucha, R.; Forte, A. M.; Mitrovica, J. X.; Pound, M. J.; Salzmann, U.; Robinson, M. M.; Chandler, M. A.; Foley, K.; Haywood, A.
2016-12-01
Past Intervals in Earth history provide unique windows into conditions much different than those observed today. We investigated the paleoenvironments of a past warm interval in the mid Piacenzian ( 3 million years ago). The PRISM4 reconstruction contains twelve internally consistent and integrated data sets representing our best synoptic understanding of surface temperature, vegetation, soils, lakes, ice sheets, topography, and bathymetry. Starting points in the generation of our Piacenzian reconstruction are basic geochemical, faunal, floral, soil, cryospheric, topographic, bathymetric, sedimentologic, and stratigraphic data. Marine and terrestral temperature estimates are based upon multiple proxies (including faunal, floral, geochemical, and biomarker analyses). The reconstruction of Piacenzian global vegetation is based on the integration of paleobotanical data and BIOME4 model outputs. Antarctic and Greenland ice sheets are derived from the previous PRISM3 and PLISMIP (Pliocene Ice Sheet Model Intercomparison Project) results, respectively. Paleogeography is based upon an initial ETOPO1 digital elevation model incorporating PRISM4 ice sheets, GIA, and adjustments due to mantle convection. Soils are determined through comparison of sedimentological and stratigraphic data with the BIOME reconstruction. Lakes are determined from stratigraphic and sedimentological data. Sea-level equivalent (+20 m) is estimated from the reduced volume of the PRISM4 ice sheets and is consistent with our PRISM4 paleogeography. While not an analog for future conditions, the PRISM4 conceptual reconstruction provides insights into processes that occurred in the past and can inform us about the future. We will discuss the use of these data as boundary conditions and verification for global climate model simulations of the Pliocene, aimed at improving our understanding of the climate system as we prepare for future changes.
NASA Astrophysics Data System (ADS)
Davydov, B. L.
2006-05-01
New crystal anisotropic prisms for splitting orthogonally polarised components of laser radiation by large angles with minimal reflection losses caused by the Brewster refraction and total internal reflection of polarised waves from the crystal—air interface are considered and the method for their calculation is described. It is shown that, by assembling glue-free combinations of two or three prisms, thermally stable beamsplitters can be fabricated, which are free from the beam astigmatism and the wave dispersion of the output angles of the beams. The parameters and properties of new beamsplitters are presented in a convenient form in figures and tables.
Jensen, Garrett; Tang, Chad; Hess, Kenneth R; Bishop, Andrew J; Pan, Hubert Y; Li, Jing; Yang, James N; Tannir, Nizar M; Amini, Behrang; Tatsui, Claudio; Rhines, Laurence; Brown, Paul D; Ghia, Amol J
2017-01-01
We sought to validate the Prognostic Index for Spinal Metastases (PRISM), a scoring system that stratifies patients into subgroups by overall survival.Methods and materials: The PRISM was previously created from multivariate Cox regression with patients enrolled in prospective single institution trials of stereotactic spine radiosurgery (SSRS) for spinal metastasis. We assess model calibration and discrimination within a validation cohort of patients treated off-trial with SSRS for metastatic disease at the same institution. The training and validation cohorts consisted of 205 and 249 patients respectively. Similar survival trends were shown in the 4 PRISM. Survival was significantly different between PRISM subgroups (P<0.0001). C-index for the validation cohort was 0.68 after stratification into subgroups. We internally validated the PRISM with patients treated off-protocol, demonstrating that it can distinguish subgroups by survival, which will be useful for individualizing treatment of spinal metastases and stratifying patients for clinical trials.
NASA Astrophysics Data System (ADS)
Kino, Saiko; Omori, Suguru; Matsuura, Yuji
2016-03-01
An attenuated-total-reflection (ATR), mid-infrared spectroscopy system that consists of hollow optical fibers, a trapezoidal multi-reflection ATR prism, and a conventional FT-IR spectrometer has been developed to measure blood glucose levels. Owing to the low transmission loss and high flexibility of the hollow-optical fiber, the system can measure any sites of the human body where blood capillaries are close to the surface of mucosa, such as inner lips. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. The results of in-vivo measurement of human inner lips showed the feasibility of the proposed system, and the measurement errors were within 20%.
Peter, Nicole; Kleinjung, Tobias; Horat, Lukas; Schmidt-Weitmann, Sabine; Meyer, Martin; Büchi, Stefan; Weidt, Steffi
2016-03-22
Chronic subjective tinnitus is a frequent condition that affects the subject's quality of life. The lack of objective measures of tinnitus necessitates the use of self-reporting and often time-consuming questionnaires for evaluating tinnitus severity. The Pictorial Representation of Illness and Self Measure (PRISM) is a two dimensional pictorial method to assess the burden of suffering. Patients illustrate their burden of suffering by the distance from a "self" to an illness circle, whereby a shorter distance indicates a higher burden of suffering. The aim of this prospective observational study was to validate the burden of suffering measured with PRISM in tinnitus patients by comparing it with different standardized questionnaires currently used in tinnitus evaluation. A total of 188 patients filled out an online-based survey including sociodemographic variables and the following questionnaires: Tinnitus Handicap Inventory (THI), Tinnitus Questionnaire (TQ), WHO Quality of Life-Questionnaire (WHOQOL-BREF), and the Beck Depression Inventory (BDI). The subtle differences in the burden of suffering were accessed by using PRISM as an iPad version. Based on PRISM performance patients could easily be assigned in three groups, these being mildly, moderately, or severely affected akin to the standard questionnaires. The burden of suffering measured with PRISM correlated with the tinnitus severity (THI and TQ), depressive symptoms (BDI), and health related quality of life (WHOQOL-BREF) (all p ≤ 0.001). In the three PRISM groups tinnitus severity (THI and TQ), and depressive symptoms (BDI) differed significantly (all p ≤ 0.01). PRISM is an easily understood and time saving method for the assessment of burden of suffering in tinnitus patients. In daily clinical practice PRISM can help to identify patients with decompensated tinnitus that require more intensive treatment.
Aqil, Anwer; Lippeveld, Theo; Hozumi, Dairiku
2009-01-01
The utility and effectiveness of routine health information systems (RHIS) in improving health system performance in developing countries has been questioned. This paper argues that the health system needs internal mechanisms to develop performance targets, track progress, and create and manage knowledge for continuous improvement. Based on documented RHIS weaknesses, we have developed the Performance of Routine Information System Management (PRISM) framework, an innovative approach to design, strengthen and evaluate RHIS. The PRISM framework offers a paradigm shift by putting emphasis on RHIS performance and incorporating the organizational, technical and behavioural determinants of performance. By describing causal pathways of these determinants, the PRISM framework encourages and guides the development of interventions for strengthening or reforming RHIS. Furthermore, it conceptualizes and proposes a methodology for measuring the impact of RHIS on health system performance. Ultimately, the PRISM framework, in spite of its challenges and competing paradigms, proposes a new agenda for building and sustaining information systems, for the promotion of an information culture, and for encouraging accountability in health systems. PMID:19304786
Excitation of surface electromagnetic waves in a graphene-based Bragg grating
Sreekanth, Kandammathe Valiyaveedu; Zeng, Shuwen; Shang, Jingzhi; Yong, Ken-Tye; Yu, Ting
2012-01-01
Here, we report the fabrication of a graphene-based Bragg grating (one-dimensional photonic crystal) and experimentally demonstrate the excitation of surface electromagnetic waves in the periodic structure using prism coupling technique. Surface electromagnetic waves are non-radiative electromagnetic modes that appear on the surface of semi-infinite 1D photonic crystal. In order to fabricate the graphene-based Bragg grating, alternating layers of high (graphene) and low (PMMA) refractive index materials have been used. The reflectivity plot shows a deepest, narrow dip after total internal reflection angle corresponds to the surface electromagnetic mode propagating at the Bragg grating/air boundary. The proposed graphene based Bragg grating can find a variety of potential surface electromagnetic wave applications such as sensors, fluorescence emission enhancement, modulators, etc. PMID:23071901
Excitation of surface electromagnetic waves in a graphene-based Bragg grating.
Sreekanth, Kandammathe Valiyaveedu; Zeng, Shuwen; Shang, Jingzhi; Yong, Ken-Tye; Yu, Ting
2012-01-01
Here, we report the fabrication of a graphene-based Bragg grating (one-dimensional photonic crystal) and experimentally demonstrate the excitation of surface electromagnetic waves in the periodic structure using prism coupling technique. Surface electromagnetic waves are non-radiative electromagnetic modes that appear on the surface of semi-infinite 1D photonic crystal. In order to fabricate the graphene-based Bragg grating, alternating layers of high (graphene) and low (PMMA) refractive index materials have been used. The reflectivity plot shows a deepest, narrow dip after total internal reflection angle corresponds to the surface electromagnetic mode propagating at the Bragg grating/air boundary. The proposed graphene based Bragg grating can find a variety of potential surface electromagnetic wave applications such as sensors, fluorescence emission enhancement, modulators, etc.
The Program for Regional and International Shorebird Monitoring (PRISM)
Bart, J.; Andres, B.; Brown, S.; Donaldson, G.; Harrington, B.; Johnston, V.; Jones, S.; Morrison, R.I.G.; Skagen, S.K.
2005-01-01
This report describes the "Program for Regional and International Shorebird Monitoring" (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird conservation plans recently completed in Canada and the United States. The goals of PRISM are to (1) estimate the size of breeding population of 74 shorebird taxa in North America; (2) describe the distribution, abundance, and habitat relationships for each of these taxa; (3) monitor trends in shorebird population size; (4) monitor shorebird numbers at stopover locations, and; (5) assist local managers in meeting their shorebird conservation goals. PRISM has four main components: arctic and boreal breeding surveys, temperate breeding surveys, temperate non-breeding surveys, and neotropical surveys. Progress on, and action items for, each major component are described. The more important major tasks for immediate action are carrying out the northern surveys, conducting regional analyses to design the program of migration counts, and evaluating aerial photographic surveys for migration and winter counts.
Sayed, Heba A; Ali, Amany M; Elzembely, Mahmoud M
2017-11-23
Pediatric Risk of Mortality Score (PRISM III-12) is a physiology-based predictor for risk of mortality. We conducted prospective study from January 1, 2014 to 2015 in pediatric oncology intensive care unit (POICU) at South Egypt Cancer Institute, Egypt to explore the ability of 1st PRISM III-12 to predict the risk of mortality in critically ill cancer patients and the ability of serial PRISM III measured every 72 hours to follow-up the patients' clinical condition during POICU stay. In total, 123 (78 males) children were included. Median age was 5 years (1 to 15 y). Death rate was 20%. 1st PRISM III-12 mean was 19 (0 to 61). The mean 1st PRISM III-12 for survivors was significantly higher compared with nonsurvivors (15 vs. 37 respectively; P<0.001). 1st PRISM III-12 mean was significantly correlated to the reasons for admission and organ failures' number (P<0.001 and <0.001). 1st PRISM III-12 correlated weakly positive with the length of stay (r=0.2; P=0.024). Receiver operator curve for 1st PRISM III-12 was 0.913 (95% confidence interval, 0.85-0.98; P<0.001). Decline in serial PRISM III was significantly correlated with favorable (survivor) outcome (P<0.001). We concluded that PRISM III-12 can be used effectively in predicting the risk of mortality and following the clinical condition of patients during POICU stay.
Prism adaptation by mental practice.
Michel, Carine; Gaveau, Jérémie; Pozzo, Thierry; Papaxanthis, Charalambos
2013-09-01
The prediction of our actions and their interaction with the external environment is critical for sensorimotor adaptation. For instance, during prism exposure, which deviates laterally our visual field, we progressively correct movement errors by combining sensory feedback with forward model sensory predictions. However, very often we project our actions to the external environment without physically interacting with it (e.g., mental actions). An intriguing question is whether adaptation will occur if we imagine, instead of executing, an arm movement while wearing prisms. Here, we investigated prism adaptation during mental actions. In the first experiment, participants (n = 54) performed arm pointing movements before and after exposure to the optical device. They were equally divided into six groups according to prism exposure: Prisms-Active, Prisms-Imagery, Prisms-Stationary, Prisms-Stationary-Attention, No Conflict-Prisms-Imagery, No Prisms-Imagery. Adaptation, measured by the difference in pointing errors between pre-test and post-test, occurred only in Prisms-Active and Prisms-Imagery conditions. The second experiment confirmed the results of the first experiment and further showed that sensorimotor adaptation was mainly due to proprioceptive realignment in both Prisms-Active (n = 10) and Prisms-Imagery (n = 10) groups. In both experiments adaptation was greater following actual than imagined pointing movements. The present results are the first demonstration of prism adaptation by mental practice under prism exposure and they are discussed in terms of internal forward models and sensorimotor plasticity. Copyright © 2012 Elsevier Ltd. All rights reserved.
The PRISM3D paleoenvironmental reconstruction
Dowsett, H.; Robinson, M.; Haywood, A.M.; Salzmann, U.; Hill, Daniel; Sohl, L.E.; Chandler, M.; Williams, Mark; Foley, K.; Stoll, D.K.
2010-01-01
The Pliocene Research, Interpretation and Synoptic Mapping (PRISM) paleoenvironmental reconstruction is an internally consistent and comprehensive global synthesis of a past interval of relatively warm and stable climate. It is regularly used in model studies that aim to better understand Pliocene climate, to improve model performance in future climate scenarios, and to distinguish model-dependent climate effects. The PRISM reconstruction is constantly evolving in order to incorporate additional geographic sites and environmental parameters, and is continuously refined by independent research findings. The new PRISM three dimensional (3D) reconstruction differs from previous PRISM reconstructions in that it includes a subsurface ocean temperature reconstruction, integrates geochemical sea surface temperature proxies to supplement the faunal-based temperature estimates, and uses numerical models for the first time to augment fossil data. Here we describe the components of PRISM3D and describe new findings specific to the new reconstruction. Highlights of the new PRISM3D reconstruction include removal of Hudson Bay and the Great Lakes and creation of open waterways in locations where the current bedrock elevation is less than 25m above modern sea level, due to the removal of the West Antarctic Ice Sheet and the reduction of the East Antarctic Ice Sheet. The mid-Piacenzian oceans were characterized by a reduced east-west temperature gradient in the equatorial Pacific, but PRISM3D data do not imply permanent El Niño conditions. The reduced equator-to-pole temperature gradient that characterized previous PRISM reconstructions is supported by significant displacement of vegetation belts toward the poles, is extended into the Arctic Ocean, and is confirmed by multiple proxies in PRISM3D. Arctic warmth coupled with increased dryness suggests the formation of warm and salty paleo North Atlantic Deep Water (NADW) and a more vigorous thermohaline circulation system that may have provided the enhanced ocean heat transport necessary to move warm surface water to the Arctic. New deep ocean temperature data also suggests greater warmth and further southward penetration of paleo NADW.
Effects of Prism Eyeglasses on Objective and Subjective Fixation Disparity
Schroth, Volkhard; Joos, Roland; Jaschinski, Wolfgang
2015-01-01
In optometry of binocular vision, the question may arise whether prisms should be included in eyeglasses to compensate an oculomotor and/or sensory imbalance between the two eyes. The corresponding measures of objective and subjective fixation disparity may be reduced by the prisms, or the adaptability of the binocular vergence system may diminish effects of the prisms over time. This study investigates effects of wearing prisms constantly for about 5 weeks in daily life. Two groups of 12 participants received eyeglasses with prisms having either a base-in direction or a base-out direction with an amount up to 8 prism diopters. Prisms were prescribed based on clinical fixation disparity test plates at 6 m. Two dependent variables were used: (1) subjective fixation disparity was indicated by a perceived offset of dichoptic nonius lines that were superimposed on the fusion stimuli and (2) objective fixation disparity was measured with a video based eye tracker relative to monocular calibration. Stimuli were presented at 6 m and included either central or more peripheral fusion stimuli. Repeated measurements were made without the prisms and with the prisms after about 5 weeks of wearing these prisms. Objective and subjective fixation disparity were correlated, but the type of fusion stimulus and the direction of the required prism may play a role. The prisms did not reduce the fixation disparity to zero, but induced significant changes in fixation disparity with large effect sizes. Participants receiving base-out prisms showed hypothesized effects, which were concurrent in both types of fixation disparity. In participants receiving base-in prisms, the individual effects of subjective and objective effects were negatively correlated: the larger the subjective (sensory) effect, the smaller the objective (motor) effect. This response pattern was related to the vergence adaptability, i.e. the individual fusional vergence reserves. PMID:26431525
Niedermann, Karin; de Bie, Rob A; Kubli, Regula; Ciurea, Adrian; Steurer-Stey, Claudia; Villiger, Peter M; Büchi, Stefan
2011-01-01
the modern joint protection (JP) concept for people with rheumatoid arthritis (RA) is an active coping strategy to improve daily tasks and role performance by changing working methods and using assistive devices. Effective group JP education includes psycho-educational interventions. The Pictorial Representation of Illness and Self Measure (PRISM) is an interactive hands-on-tool, assessing (a) the individual's perceived burden of illness and (b) relevant individual resources. Both issues are important for intrinsic motivation to take action and change behaviour. This study compared individual conventional JP education (C-JP) with PRISM-based JP education (PRISM-JP). an assessor-blinded multicentre randomized controlled trial, including four JP education sessions over 3 weeks, with assessments at baseline and 3 months. in total 53 RA patients participated. At 3 months, the PRISM-JP (n=26) participants did significantly better compared to the C-JP participants (n=27) in JP behaviour (p=0.02 and p=0.008 when corrected for baseline values), Arthritis Self-efficacy (ASES, p=0.015) and JP self-efficacy (JP-SES, p=0.047). Within-group analysis also showed less hand pain (p<0.001) in PRISM-JP group. PRISM-JP more effectively supported learning of JP methods, with meaningful occupations, resource activation and self-efficacy acting as important mediators. PRISM improved patient-clinician communication and is feasible for occupational therapy. 2010 Elsevier Ireland Ltd. All rights reserved.
Composite Yb:YAG/SiC-prism thin disk laser.
Newburgh, G A; Michael, A; Dubinskii, M
2010-08-02
We report the first demonstration of a Yb:YAG thin disk laser wherein the gain medium is intracavity face-cooled through bonding to an optical quality SiC prism. Due to the particular design of the composite bonded Yb:YAG/SiC-prism gain element, the laser beam impinges on all refractive index interfaces inside the laser cavity at Brewster's angles. The laser beam undergoes total internal reflection (TIR) at the bottom of the Yb(10%):YAG thin disk layer in a V-bounce cavity configuration. Through the use of TIR and Brewster's angles, no optical coatings, either anti-reflective (AR) or highly reflective (HR), are required inside the laser cavity. In this first demonstration, the 936.5-nm diode pumped laser performed with approximately 38% slope efficiency at 12 W of quasi-CW (Q-CW) output power at 1030 nm with a beam quality measured at M(2) = 1.5. This demonstration opens up a viable path toward novel thin disk laser designs with efficient double-sided room-temperature heatsinking via materials with the thermal conductivity of copper on both sides of the disk.
Robach, J S; Stock, S R; Veis, A
2009-12-01
Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass spectroscopy). The study focused on the internal structure of the first-stage mineral structures of high Mg calcite (primary, secondary and carinar process plates, prisms) and on morphology of the columns of second-stage mineral (very high Mg calcite) that cement the first-stage material together. Optical micrographs under polarized light revealed contrast in the centers (midlines) of carinar process plates and in prisms in polished sections; staining of primary and carinar process plates revealed significant dye uptake at the plate centers. Demineralization with and without fixation revealed that the midlines of primary and carinar process plates (but not secondary plates) and the centers of prisms differed from the rest of the plate or prism, and SIMS showed proteins concentrated in these plate centers. SEM was used to study the morphology of columns, the fracture surfaces of mature teeth and the 3D morphology of prisms. These observations of internal structures in plates and prisms offer new insight into the mineralization process and suggest an important role for protein inclusions within the first-stage mineral. Some of the 3D structures not reported previously, such as twisted prisms and stacks of carinar process plates with nested wrinkles, may represent structural strengthening strategies.
Robach, J. S.; Stock, S. R.; Veis, A.
2009-01-01
Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass spectroscopy). The study focused on the internal structure of the first-stage mineral structures of high Mg calcite (primary, secondary and carinar process plates; prisms) and on morphology of the columns of second-stage mineral (very high Mg calcite) that cement the first-stage material together. Optical micrographs under polarized light revealed contrast in the centers (midlines) of carinar process plates and in prisms in polished sections; staining of primary and carinar process plates revealed significant dye uptake at the plate centers. Demineralization with and without fixation revealed that the midlines of primary and carinar process plates (but not secondary plates) and the centers of prisms differed from the rest of the plate or prism, and SIMS showed proteins concentrated in these plate centers. SEM was used to study the morphology of columns, the fracture surfaces of mature teeth and the 3D morphology of prisms. These observations of internal structures in plates and prisms offer new insight into the mineralization process and suggest an important role for protein inclusions within the first-stage mineral. Some of the 3D structures not reported previously, such as twisted prisms and stacks of carinar process plates with nested wrinkles, may represent structural strengthening strategies. PMID:19616101
A Feasibility Study on Generation of Acoustic Waves Utilizing Evanescent Light
NASA Astrophysics Data System (ADS)
Matsuya, I.; Matozaki, K.; Kosugi, A.; Ihara, I.
2014-06-01
A new approach of generating acoustic waves utilizing evanescent light is presented. The evanescent light is a non-propagating electromagnetic wave that exhibits exponential decay with distance from the surface at which the total internal reflection of light is formed. In this research, the evanescent light during total internal reflection at prism surface is utilized for generating acoustic waves in aluminium and the feasibility for ultrasonic measurements is discussed. Pulsed Nd:YAG laser with 0.36 J/cm2 power density is used and the incident angle during the total internal reflection is arranged to be 69.0° for generating the evanescent light. It has been demonstrated that the amplitude of the acoustic waves by means of evanescent light is about 1/14 as large as the one generated by the conventional pulsed laser. This reveals the possibility of using a laser ultrasonic technique with near-field optics.
Kuang, Yi; Long, Marcus J. C.; Zhou, Jie; Shi, Junfeng; Gao, Yuan; Xu, Chen; Hedstrom, Lizbeth; Xu, Bing
2014-01-01
Emerging evidence reveals that prion-like structures play important roles to maintain the well-being of cells. Although self-assembly of small molecules also affords prion-like nanofibrils (PriSM), little is known about the functions and mechanisms of PriSM. Previous works demonstrated that PriSM formed by a dipeptide derivative selectively inhibiting the growth of glioblastoma cells over neuronal cells and effectively inhibiting xenograft tumor in animal models. Here we examine the protein targets, the internalization, and the cytotoxicity pathway of the PriSM. The results show that the PriSM selectively accumulate in cancer cells via macropinocytosis to impede the dynamics of cytoskeletal filaments via promiscuous interactions with cytoskeletal proteins, thus inducing apoptosis. Intriguingly, Tau proteins are able to alleviate the effect of the PriSM, thus protecting neuronal cells. This work illustrates PriSM as a new paradigm for developing polypharmacological agents that promiscuously interact with multiple proteins yet result in a primary phenotype, such as cancer inhibition PMID:25157102
Transparent Solar Concentrator for Flat Panel Display
NASA Astrophysics Data System (ADS)
Yeh, Chia-Hung; Chang, Fuh-Yu; Young, Hong-Tsu; Hsieh, Tsung-Yen; Chang, Chia-Hsiung
2012-06-01
A new concept of the transparent solar concentrator for flat panel display is experimentally demonstrated without adversely affecting the visual effects. The solar concentrator is based on a solar light-guide plate with micro prisms, not only increasing the absorption area of solar energy but also enhancing the conversion efficiency. The incident light is guided by the designed solar light-guide plate according to the total internal reflection (TIR), and converted into electrical power by photovoltaic solar cells. The designed transparent solar concentrator was made and measured with high transparency, namely 94.8%. The developed solar energy system for display can store energy and supply the bias voltage to light on two light-emitting diodes (LEDs) successfully.
Hsu, Benson S; Lakhani, Saquib; Brazelton, Thomas B
2015-08-01
To estimate the impact of severity of illness and length of stay on costs incurred during a pediatric intensive care unit (PICU) hospitalization. This is a retrospective cohort study at an academic PICU located in the U.S. that examined 850 patients admitted to the PICU from Jan. 1 to Dec. 31, 2009. The study population was segmented into three severity levels based on pediatric risk of mortality (PRISM) III scores: low (PRISM score 0), medium (PRISM score 1-5), and high (PRISM score greater than 5). Outcome measures were total and daily PICU costs (2009 U.S. dollars). Eight hundred and fifty patients were admitted to the PICU during the study period. Forty-eight patients (5.6 percent) had incomplete financial data and were excluded from further analysis. Mean total PICU costs for low (n = 429), medium (n = 211), and high (n = 162) severity populations were $21,043, $37,980, and $55,620 (p < 0.001). Mean daily PICU costs for the low, medium, and high severity groups were $5,138, $5,903, and $5,595 (p = 0.02). Higher severity of illness resulted in higher total PICU costs. Interestingly, although daily PICU costs across severity of illness showed a statistically significant difference, the practical economic difference was minimal, emphasizing the importance of length of stay to total PICU costs. Thus, the study suggested that reducing length of stay independent of illness severity may be a practical cost control measure within the pediatric intensive care setting.
NASA Astrophysics Data System (ADS)
Moore, J. C.; Chester, F. M.
2015-12-01
The stratigraphic sequence within the frontal accretionary prism of the Japan Trench, the site of large slip during the Tohoku earthquake, is unique due to horst and graben subduction. Boreholes at IODP Site C0019, penetrating the toe of the Tohoku accretionary prism, document a younger over older intraprism thrust contact with a 9 Ma age gap across the basal plate boundary fault. The anomalously young (Quaternary to Pliocene), fault-bounded sediment package is 130 m thick, of a total of 820 m of sediment above the plate boundary fault. In contrast, typical accretionary prism structure consists of stacked sediment packages on imbricate faults above the basal decollement resulting in an overall increase in age downward. Site C0019 penetrates the prism directly above a horst of the subducting Pacific oceanic crust. Here the plate-boundary fault consists of a thin, weak smectitic pelagic clay that is probably the principal slip surface of ~50 m offset in the 2011 Tohoku earthquake. The fault continues seaward deepening off the seaward edge of the horst and beneath the sediment fill of the adjacent graben, dying out at the landward base of the next incoming horst. The plate boundary fault and its splays in the graben form a narrow-taper protoprism and a small sedimentary basin of trench fill marking the seaward edge of the upper plate. The modern fault and sediment distributions within the graben are used to motivate a viable model for the presence of anomalously young sediments directly above the plate boundary fault. In this model sediments in the trench are thrust over the incoming horst by propagation of the plate boundary thrust up the landward-dipping fault of the incoming horst and along the smectitic clay layer to emplace Quaternary and Pliocene trench deposits directly on top of the incoming horst. These young deposits are in turn overlain by sediments 9 Ma or older that have been transported out of the graben along imbricate faults associated with the necessary increase in the taper of the prism above the graben. The Quaternary to Pliocene units thicken due to internal deformation accounting for the 130 m thickness now observed over the plate boundary fault at Site C0019. Conversely emplacement of very young sediment directly above a basal detachment would be unexpected in accretionary prisms subducting smoother oceanic crust.
Simplified design of thin-film polarizing beam splitter using embedded symmetric trilayer stack.
Azzam, R M A
2011-07-01
An analytically tractable design procedure is presented for a polarizing beam splitter (PBS) that uses frustrated total internal reflection and optical tunneling by a symmetric LHL trilayer thin-film stack embedded in a high-index prism. Considerable simplification arises when the refractive index of the high-index center layer H matches the refractive index of the prism and its thickness is quarter-wave. This leads to a cube design in which zero reflection for the p polarization is achieved at a 45° angle of incidence independent of the thicknesses of the identical symmetric low-index tunnel layers L and L. Arbitrarily high reflectance for the s polarization is obtained at subwavelength thicknesses of the tunnel layers. This is illustrated by an IR Si-cube PBS that uses an embedded ZnS-Si-ZnS trilayer stack.
Kuang, Yi; Long, Marcus J C; Zhou, Jie; Shi, Junfeng; Gao, Yuan; Xu, Chen; Hedstrom, Lizbeth; Xu, Bing
2014-10-17
Emerging evidence reveals that prion-like structures play important roles to maintain the well-being of cells. Although self-assembly of small molecules also affords prion-like nanofibrils (PriSM), little is known about the functions and mechanisms of PriSM. Previous works demonstrated that PriSM formed by a dipeptide derivative selectively inhibiting the growth of glioblastoma cells over neuronal cells and effectively inhibiting xenograft tumor in animal models. Here we examine the protein targets, the internalization, and the cytotoxicity pathway of the PriSM. The results show that the PriSM selectively accumulate in cancer cells via macropinocytosis to impede the dynamics of cytoskeletal filaments via promiscuous interactions with cytoskeletal proteins, thus inducing apoptosis. Intriguingly, Tau proteins are able to alleviate the effect of the PriSM, thus protecting neuronal cells. This work illustrates PriSM as a new paradigm for developing polypharmacological agents that promiscuously interact with multiple proteins yet result in a primary phenotype, such as cancer inhibition. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Refractive index profilometry using the total internally reflected light field.
Das, Tania; Bhattacharya, K
2017-11-20
A full-field polarization-based technique is presented for quantitative evaluation of the spatial distribution of the refractive index in macro and micro samples. The sample is mounted on a glass-air interface of a prism, illuminated by a linearly polarized collimated light beam, and two intensity frames are digitally recorded with specific orientations of an analyzer. The pair of intensity data frames captured with this simple setup is combined through an algorithm specially developed for the purpose, to yield the phase difference between the transverse electric and transverse magnetic components of the total internally reflected light field. The phase difference is then related to the refractive index of the sample. Experimental results for refractive index variations in a laser-etched glass plate and red blood corpuscles are presented. One of the salient features of the proposed technique is that the depth of measurement is dependent on the penetration depth of the sample's evanescent field, which is typically of the order of a few hundred nanometers, thereby facilitating refractive index measurements along a thin section of the sample.
Laser-based study of geometrical optics at school level
NASA Astrophysics Data System (ADS)
Garg, Amit; Dhingra, Vishal; Sharma, Reena; Mittal, Ankit; Tiwadi, Raman; Chakravarty, Pratik
2011-10-01
Students at the school level from grade 7 to 12 are taught various concepts of geometrical optics but with little hands-on activities. Light propagation through different media, image formation using lenses and mirrors under different conditions and application of basic principles to characterization of lenses, mirrors and other instruments has been a subject which although fascinates students but due to lack of suitable demonstrating setups, students find difficulty in understanding these concepts and hence unable to appreciate the importance of such concepts in various useful scientific apparatus, day to day life, instruments and devices. Therefore, students tend to cram various concepts related to geometrical optics instead of understanding them. As part of the extension activity in the University Grants Commission major research project "Investigating science hands-on to promote innovation and research at undergraduate level" and University of Delhi at Acharya Narendra Dev College SPIE student chapter, students working under this optics outreach programme have demonstrated various experiments on geometrical optics using a five beam laser ray box and various optical components like different types of mirrors, lenses, prisms, optical fibers etc. The various hands-on activities includes demonstrations on laws of reflection, image formation using plane, concave and convex mirrors, mirror formula, total internal reflection, light propagation in an optical fiber, laws of refraction, image formation using concave and convex lenses and combination of these lenses, lens formula, light propagation through prisms, dispersion in prism, defects in eye- Myopia and hypermetropia. Subjects have been evaluated through pre and post tests in order to measure the improvement in their level of understanding.
Comparison of near fusional vergence ranges with rotary prisms and with prism bars.
Goss, David A; Becker, Emily
2011-02-01
Common methods for determination of fusional vergence ranges make use of rotary prisms in the phoropter or prism bars out of the phoropter. This study compared near fusional vergence ranges with rotary prisms with those with prism bars. Fifty young adults served as subjects. Odd-numbered subjects had rotary prism vergences performed before prism bar vergences. For even-numbered subjects, prism bar vergences were done first. Base-in (BI) vergences were done before base-out (BO) vergences with both rotary prisms and prism bars. A coefficient of agreement was calculated by multiplying the standard deviation of the individual subject differences between rotary prisms and prism bars by 1.96, to approximate the range within which the 2 tests would agree 95% of the time. The lowest coefficient of agreement was 7.3Δ for the BI recovery. The others were high, ranging from 15.4Δ for the BO recovery to 19.5Δ for the BO break. Fusional vergence ranges determined by prism bars out of the phoropter cannot be used interchangeably with those determined by phoropter rotary prisms for the purpose of follow-up on individual patients or for the purpose of comparison with norms. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
The infrared bands Pechan prism axis parallel detection method
NASA Astrophysics Data System (ADS)
Qiang, Hua; Ji, Ming; He, Yu-lan; Wang, Nan-xi; Chang, Wei-jun; Wang, Ling; Liu, Li
2017-02-01
In this paper, we put forward a new method to adjust the air gap of the total reflection air gap of the infrared Pechan prism. The adjustment of the air gap in the air gap of the Pechan prism directly affects the parallelism of the optical axis, so as to affect the consistency of the optical axis of the infrared system. The method solves the contradiction between the total reflection and the high transmission of the infrared wave band, and promotes the engineering of the infrared wave band. This paper puts forward the method of adjusting and controlling, which can ensure the full reflection and high penetration of the light, and also can accurately measure the optical axis of the optical axis of the different Pechan prism, and can achieve the precision of the level of the sec. For Pechan prism used in the infrared band image de rotation, make the product to realize miniaturization, lightweight plays an important significance.
The effect of prism on preferred retinal locus.
Lewerenz, David; Blanco, Daniel; Ratzlaff, Chase; Zodrow, Ashley
2018-03-01
Whether prism, especially base-up prism, affects the area of the retina used for fixation in a patient with central scotoma has been a controversial subject for 35 years. Our pilot study employed microperimetry to evaluate the effect of base-up prism on the fixation locus, or preferred retinal locus (PRL), in subjects with central scotoma. We used a microperimeter to assess the PRL in 13 visually impaired subjects with central scotoma under four conditions: no lens, a lens with no prism (control lens), 6 Δ base-up, and 10 Δ base-up. The PRL was measured in degrees in horizontal and vertical co-ordinates from the centre of the optic disc using graphical analysis. The PRL with the control lens was not significantly different from the PRL with no lens. The preferred retinal loci with the two powers of prism were compared to the control lens and showed a superior shift in 22 of 26 cases (84.6 per cent). The amount of movement was significantly different from zero (p = 0.001 for 6 Δ and p = 0.004 for 10 Δ ). The vertical movement with the 10 Δ prism (1.73 ± 1.73 degrees) was not significantly greater (p = 0.562) than with the 6 Δ prism (1.37 ± 1.08 degrees). The shift was significantly less than the prism powers used (p < 0.001), and the amount of vertical relocation was not significantly different from the amount of horizontal movement. In our study, base-up prism appears to shift the PRL in the direction of the prism base most of the time, but our findings do not support the use of prism as a way of predictably relocating the PRL. More study is indicated to evaluate whether such a small shift is clinically or functionally significant. © 2017 Optometry Australia.
[Prism adaptation test before strabismus surgery : Results of a survey and literature review].
Pichler, U; Rohleder, M; Ehrt, O
2018-02-01
Variable preoperative deviations and compensatory mechanisms may cause wrong dosage of strabismus surgery and result in over- or undercorrection. A long-lasting prism adaptation test (PAT) before surgery is supposed to reduce those difficulties and to improve the postoperative results. To date, the use of prism adaptation before surgery has not been systematically examined. A total of 15 strabismologists and 28 orthoptists in Austria were interviewed about their approach to prism adaptation in 9 types of strabismus. They were also asked about the basis of their decision for a certain treatment regime. Of those interviewed, 28% performed preoperative prism adaptation for weeks to years. Of those, 7% based their decision on evidence from the literature, 54% decide on personal experience, 15% due to guidelines of their institution, and 23% follow the teaching of their medical school. Reports in the literature reveal inconsistent results on PAT. In published studies, PAT was rarely performed longer than 4 weeks and only shows significant improvements on outcome in particular pathologies as acquired esotropia. Long-term PAT appears questionable as to date there is no evidence for a better postoperative outcome. Before setting up guidelines, further controlled, prospective studies on PAT must be conducted.
Preparation of regional shorebird monitoring plans
Jonathan Bart; Ann Manning; Susan Thomas; Catherine Wightman
2005-01-01
Shorebird monitoring programs in Canada and the United States are being developed under the auspices of PRISM, the Program for Regional and International Shorebird Monitoring. PRISM provides a single blueprint for implementing the monitoring proposals in the shorebird conservation plans prepared recently in Canada and the United States. It includes four segments:...
Uncovering the Stories about Social Class
ERIC Educational Resources Information Center
Harper, Vernon B., Jr.
2006-01-01
Social class remains one of the chief prisms through which reality is interpreted. It is vital for a student to understand how this prism influences their internal representations of themselves and others. In this activity, social class is viewed as a social construction of perceived financial and/or economic status developed through societal…
Pointing error analysis of Risley-prism-based beam steering system.
Zhou, Yuan; Lu, Yafei; Hei, Mo; Liu, Guangcan; Fan, Dapeng
2014-09-01
Based on the vector form Snell's law, ray tracing is performed to quantify the pointing errors of Risley-prism-based beam steering systems, induced by component errors, prism orientation errors, and assembly errors. Case examples are given to elucidate the pointing error distributions in the field of regard and evaluate the allowances of the error sources for a given pointing accuracy. It is found that the assembly errors of the second prism will result in more remarkable pointing errors in contrast with the first one. The pointing errors induced by prism tilt depend on the tilt direction. The allowances of bearing tilt and prism tilt are almost identical if the same pointing accuracy is planned. All conclusions can provide a theoretical foundation for practical works.
First-order approximation error analysis of Risley-prism-based beam directing system.
Zhao, Yanyan; Yuan, Yan
2014-12-01
To improve the performance of a Risley-prism system for optical detection and measuring applications, it is necessary to be able to determine the direction of the outgoing beam with high accuracy. In previous works, error sources and their impact on the performance of the Risley-prism system have been analyzed, but their numerical approximation accuracy was not high. Besides, pointing error analysis of the Risley-prism system has provided results for the case when the component errors, prism orientation errors, and assembly errors are certain. In this work, the prototype of a Risley-prism system was designed. The first-order approximations of the error analysis were derived and compared with the exact results. The directing errors of a Risley-prism system associated with wedge-angle errors, prism mounting errors, and bearing assembly errors were analyzed based on the exact formula and the first-order approximation. The comparisons indicated that our first-order approximation is accurate. In addition, the combined errors produced by the wedge-angle errors and mounting errors of the two prisms together were derived and in both cases were proved to be the sum of errors caused by the first and the second prism separately. Based on these results, the system error of our prototype was estimated. The derived formulas can be implemented to evaluate beam directing errors of any Risley-prism beam directing system with a similar configuration.
Single-lens stereovision system using a prism: position estimation of a multi-ocular prism.
Cui, Xiaoyu; Lim, Kah Bin; Zhao, Yue; Kee, Wei Loon
2014-05-01
In this paper, a position estimation method using a prism-based single-lens stereovision system is proposed. A multifaced prism was considered as a single optical system composed of few refractive planes. A transformation matrix which relates the coordinates of an object point to its coordinates on the image plane through the refraction of the prism was derived based on geometrical optics. A mathematical model which is able to denote the position of an arbitrary faces prism with only seven parameters is introduced. This model further extends the application of the single-lens stereovision system using a prism to other areas. Experimentation results are presented to prove the effectiveness and robustness of our proposed model.
NASA Astrophysics Data System (ADS)
Manietyev, Leonid; Khoreshok, Aleksey; Tsekhin, Alexander; Borisov, Andrey
2017-11-01
The directions of a resource and energy saving when creating a boom-type effectors of roadheaders of selective action with disc rock cutting tools on a multi-faceted prisms for the destruction of formation of minerals and rocks pricemax are presented. Justified reversing the modes of the crowns and booms to improve the efficiency of mining works. Parameters of destruction of coal and rock faces by the disk tool of a biconical design with the unified fastening knots to many-sided prisms on effectors of extraction mining machines are determined. Parameters of tension of the interfaced elements of knots of fastening of the disk tool at static interaction with the destroyed face of rocks are set. The technical solutions containing the constructive and kinematic communications realizing counter and reverse mode of rotation of two radial crowns with the disk tool on trihedral prisms and cases of booms with the disk tool on tetrahedral prisms in internal space between two axial crowns with the cutter are proposed. Reserves of expansion of the front of loading outside a table of a feeder of the roadheader of selective action, including side zones in which loading corridors by blades of trihedral prisms in internal space between two radial crowns are created are revealed.
Fresnel prisms and their effects on visual acuity and binocularity.
Véronneau-Troutman, S
1978-01-01
1. The visual acuity with the Fresnel membrane prism is significantly less than that with the conventional prism of the same power for all prism powers from 12 delta through 30 delata at distance and from 15 delta through 30 delta at near. 2. The difference in the visual acuity between base up and base down, and between base in and base out, is not significantly different for either the Fresnel membrane prism or for the conventional prism. 3. For both Fresnel membrane prism and the conventional prism, the visual acuity when looking straight ahead. 4. Using Fresnel membrane prisms of the same power from different lots, the visual acuity varied significantly. The 30 delta prism caused the widest range in visual acuity. 5. When normal subjects are fitted with the higher powers of the Fresnel membrane prism, fusion and stereopsis are disrupted to such an extent that the use of this device to restore or to improve binocular vision in cases with large-angle deviations is seriously questioned. 6. Moreover, the disruption of fusion and stereopsis is abrupt and severe and does not parallel the decrease in visual acuity. The severely reduced ability to maintain fusion may be related to the optical aberrations, which, in turn, may be due to the molding process and the polyvinyl chloride molding material. 7. Through the flexibility of the membrane prism is a definite advantage, because of its proclivity to reduce visual acuity and increase aberrations its prescription for adults often must be limited to only one eye. 8. For the same reasons in the young child with binocular vision problems, the membrane prism presently available should be prescribed over both eyes only in powers less than 20 delta. When the membrane prism is to be used as a partial occluder (over one eye only), any power can be used. 9. The new Fresnel "hard" prism reduces visual acuity minimally and rarely disrupts binocularity, thus increasing the potential for prismotherapy to establish binocularity. This prism is currently available only for use as a trial set. Since the cosmetic appearance of the Fresnel "hard" prism is similar to that of the Fresnel membrane prism and it is easier to maintain, it would be the prism of choice (over all other types) for bilateral prescriptions in the young patient with emmetropia. The manufacturer is urged to make these prisms available to fit a special round adjustable frame, such as that developed in Europe for use with the wafer prism. Images FIGURE 14 A FIGURE 14 B FIGURE 2 A FIGURE 2 B FIGURE 12 PMID:754384
NASA Technical Reports Server (NTRS)
Curley, Michael J. (Inventor); Sarkisov, Sergey S. (Inventor)
2008-01-01
A refractometer computer controls the rotation of a rotary plate upon which are mounted a prism optically coupled via an optical window to a spectroscopic cell holding a resin exhibiting a dynamic refractive index during photocuring. The computer system positions the prism and spectroscopic cell relative to a visible light laser which illuminates the prism-resin interface at selected incidence angles. A photodetector mounted on the plate generates a signal to the computer proportional to intensity of an internally reflected light beam. A curing light is selectively transmitted through the prism and into the photocurable resin. The refractometer determines the intensity of the internally reflected beam a selected incidence angles and determines the effective refractive index curve of the resin at an uncured state and, optionally, at a completely cured state. Next, an amount of uncured resin and selected optical components to be joined by the resin is placed in the spectroscopic cell and irradiated with the UV light. The refractometer is fixed at a selected incidence angle and measures the intensity of an internally reflected light beam of light throughout the cure cycle. The refractometer determines the resin's refractive index of the polymeric mixture by means of extrapolation of a horizontal shift in the effective refractive index curve of the resin from an uncured state to a selected point in the cure cycle.
Spectral Analysis of the Shuttle Glow. AIS Science Support
1992-06-23
Prism (Total Internal Cylindrical Mirror Lens Reflection) Cylindrical Folding \\ Lens Plane Mirror -Cylindrical Slt Slit Mirror Fig. 7. Cron section...on Zerodur blanks, which width of the FOV to 0.14’ outward from the lens. have a coefficient of thermal expansion near zero. The width of the grating...oummambne toathe window of the iMag hunte~air. 3002. APPLIED OPTICS I VOL 3 .No, 16 / I June I02 68 Vacondry Minrror Prmr Mirror -luterence rlZters cm
Disposable versus non-disposable tonometer prisms: a UK national survey
Jasani, Kirti M; Putri, Christine; Pearl, Amy; Sattar, Nayeem; Mercieca, Karl; Spaeth, George; Bhan-Bhargava, Archana
2017-01-01
Purpose To determine the prevalence of disposable tonometer versus non-disposable tonometer use in the UK and to determine methods of decontamination and frequency of replacement of prisms. A total of 137 ophthalmology departments were interviewed by telephone using a structured questionnaire. The main outcome measured were:types of tonometer prisms used in clinic (disposable, non-disposable and/or other)average disposable prisms used per clinic sessionaverage lifespan of non-disposable prismsprism preference by glaucoma and other teams within department. A cost and benefit analysis was then performed on the data acquired. Results One hundred and fifty-five departments were identified for the survey. Of these, 137 (88.3%) responded. Eighty-one departments (59.1%) used Tonosafe prisms alone, whereas 22 departments (16.1%) used Goldmann non-disposable prisms exclusively. Thirty-five departments (64%) on average have a change rate of 26.5% per year (range: 0–100, median: 20) attributed to damage, loss or theft. Sixteen departments (29%) reported that prisms were used until damaged or lost. Four departments (7%) were uncertain of their prism usage and could not provide further information. Conclusions Majority of eye departments in the UK opt for disposable prisms. This survey shows the perceived cost-effectiveness of disposable prisms is overestimated when the true cost of disinfection and damage is taken into account. Significant cost savings coupled with the low risk of infectivity (if decontaminated properly) should prompt clinicians and ophthalmic departments worldwide to reconsider the use of non-disposable prisms. PMID:29354698
Fang, Ning; Sun, Wei
2015-04-21
A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.
Dielectric prisms would improve performance of quasi-optical microwave components
NASA Technical Reports Server (NTRS)
Carson, J. W.
1967-01-01
Properties of the Brewster angle and internal reflection in a dielectric prism are proposed as the basis of a new type of element for use in oversize waveguide in quasi-optical microwave components. Waveguide loss is reduced and precision broadband attenuators, phase shifters, and directional couplers can be constructed on the basis of the properties.
PRISM: Priority Symptom Management Project phase I: assessment.
Ropka, M E; Spencer-Cisek, P
2001-01-01
To provide an overview of the process, goals, and outcome recommendations from the assessment phase of the Oncology Nursing Society's Priority Symptom Management (PRISM) project and to provide the foundation for a series of evidence-based practice and qualitative systematic review articles generated from the first phase of PRISM. Published articles, abstracts, and books; computerized databases; nonpublished research; personal communications; and proceedings of the PRISM summit meeting. Symptom management is a key component in quality cancer care. The assessment phase of PRISM yielded systematic reviews with an evidence-based framework to evaluate key symptoms, developed a framework for teaching and evaluating other symptoms, and recommended future ONS initiatives. Outcome recommendations from the PRISM summit targeted practice; professional and public education; research; and health policy. These activities provide background for subsequent evidence-based practice and qualitative systematic review articles that will focus on cancer symptom management.
Berndtson, Allison E; Sen, Soman; Greenhalgh, David G; Palmieri, Tina L
2013-09-01
The purpose of our study is to validate the Pediatric Risk of Mortality (PRISM) score and compare the accuracy of PRISM predicted outcomes to the Abbreviated Burn Severity Index (ABSI). We hypothesized that the PRISM score is more accurate in predicting mortality and hospital length of stay than the ABSI in children with severe burns. All children <18 years of age admitted to a regional pediatric burn center between January 1, 2008 and July 1, 2010 were reviewed. Those with a Total Body Surface Area (TBSA) burn ≥20% who were admitted within 7 days of injury were selected for our study. Measured parameters included: demographics, burn characteristics, PRISM and ABSI scores at admission, and outcomes (mortality, hospital length of stay (LOS), ventilator days and cause of death). A total of 83 patients met criteria and had complete data sets. The mean age (±SEM) was 8.0±0.6 years, mean % TBSA burn 49.9±2.1%, 62.7% were male, and 45.8% had inhalation injury. Hospital LOS was 74.4±7.9 days, with 31.5±4.9 ventilator days. Mean PRISM score ranged from 14.2 to 16.0, with ABSI scores 7.9 to 8.5. Actual overall mortality was 18.1% compared to a PRISM predicted mortality of 19.8±2.5% (p<0.001, r=0.570). ABSI predicted mortality varied from 10 to 20% for a score of 7.9 to 30-50% for a score of 8.5. Logistic regression showed that both PRISM (p<0.001) and ABSI (p<0.001) mortality predictions accurately estimated actual mortality, which remained true in a combined model. ABSI was predictive of hospital LOS (p<0.001) and ventilator days (p<0.001) while PRISM was not (p=0.326 and p=0.863). Both PRISM and ABSI scores are predictive of mortality in severely burned children. Only ABSI correlates with hospital length of stay and ventilator days, and thus may also be more useful in predicting ICU resource utilization. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
High-Power Prismatic Devices for Oblique Peripheral Prisms
Peli, Eli; Bowers, Alex R.; Keeney, Karen; Jung, Jae-Hyun
2016-01-01
ABSTRACT Purpose Horizontal peripheral prisms for hemianopia provide field expansion above and below the horizontal meridian; however, there is a vertical gap leaving the central area (important for driving) without expansion. In the oblique design, tilting the bases of both prism segments toward the horizontal meridian moves the field expansion area vertically and centrally (closing the central gap) while the prisms remain in the peripheral location. However, tilting the prisms results also in a reduction of the lateral field expansion. Higher prism powers are needed to counter this effect. Methods We developed, implemented, and tested a series of designs aimed at increasing the prism power to reduce the central gap while maintaining wide lateral expansion. The designs included inserting the peripheral prisms into carrier lenses that included yoked prism in the opposite direction, combination of two Fresnel segments attached at the base and angled to each other (bi-part prisms), and creating Fresnel prism–like segments from nonparallel periscopic mirror pairs (reflective prisms). Results A modest increase in lateral power was achieved with yoked-prism carriers. Bi-part combination of 36Δ Fresnel segments provided high power with some reduction in image quality. Fresnel reflective prism segments have potential for high power with superior optical quality but may be limited in field extent or by interruptions of the expanded field. Extended apical scotomas, even with unilateral fitting, may limit the utility of very high power prisms. The high-power bi-part and reflective prisms enable a wider effective eye scanning range (more than 15 degrees) into the blind hemifield. Conclusions Conventional prisms of powers higher than the available 57Δ are limited by the binocular impact of a wider apical scotoma and a reduced effective eye scanning range to the blind side. The various designs that we developed may overcome these limitations and find use in various other field expansion applications. PMID:26866438
Studying the neural bases of prism adaptation using fMRI: A technical and design challenge.
Bultitude, Janet H; Farnè, Alessandro; Salemme, Romeo; Ibarrola, Danielle; Urquizar, Christian; O'Shea, Jacinta; Luauté, Jacques
2017-12-01
Prism adaptation induces rapid recalibration of visuomotor coordination. The neural mechanisms of prism adaptation have come under scrutiny since the observations that the technique can alleviate hemispatial neglect following stroke, and can alter spatial cognition in healthy controls. Relative to non-imaging behavioral studies, fMRI investigations of prism adaptation face several challenges arising from the confined physical environment of the scanner and the supine position of the participants. Any researcher who wishes to administer prism adaptation in an fMRI environment must adjust their procedures enough to enable the experiment to be performed, but not so much that the behavioral task departs too much from true prism adaptation. Furthermore, the specific temporal dynamics of behavioral components of prism adaptation present additional challenges for measuring their neural correlates. We developed a system for measuring the key features of prism adaptation behavior within an fMRI environment. To validate our configuration, we present behavioral (pointing) and head movement data from 11 right-hemisphere lesioned patients and 17 older controls who underwent sham and real prism adaptation in an MRI scanner. Most participants could adapt to prismatic displacement with minimal head movements, and the procedure was well tolerated. We propose recommendations for fMRI studies of prism adaptation based on the design-specific constraints and our results.
NASA Astrophysics Data System (ADS)
Jurado, Maria Jose
2016-04-01
IODP has extensively used the D/V Chikyu to drill the Kumano portion of the Nankai Trough, including two well sites within the Kumano Basin. IODP Expeditions 338 and 348 drilled deep into the inner accretionary prism south of the Kii Peninsula collecting a suite of LWD data, including natural gamma ray, electrical resistivity logs and borehole images, suitable to characterize structures (fractures and faults) inside the accretionary prism. Structural interpretation and analysis of logging-while-drilling data in the deep inner prism revealed intense deformation of a generally homogenous lithology characterized by bedding that dips steeply (60-90°) to the NW, intersected by faults and fractures. Multiple phases of deformation are characterized. IODP Expedition borehole images and LWD data acquired in the last decade in previous and results of NantroSEIZE IODP Expeditions (314, 319) were also analyzed to investigate the internal geometries and structures of the Nankai Trough accretionary prism. This study focused mainly on the characterization of the different types of structures and their specific position within the accretionary prism structures. New structural constraints and methodologies as well as a new approach to the characterization of study of active structures inside the prism will be presented.
Jacquin-Courtois, S; Rode, G; Pavani, F; O'Shea, J; Giard, M H; Boisson, D; Rossetti, Y
2010-03-01
Unilateral neglect is a disabling syndrome frequently observed following right hemisphere brain damage. Symptoms range from visuo-motor impairments through to deficient visuo-spatial imagery, but impairment can also affect the auditory modality. A short period of adaptation to a rightward prismatic shift of the visual field is known to improve a wide range of hemispatial neglect symptoms, including visuo-manual tasks, mental imagery, postural imbalance, visuo-verbal measures and number bisection. The aim of the present study was to assess whether the beneficial effects of prism adaptation may generalize to auditory manifestations of neglect. Auditory extinction, whose clinical manifestations are independent of the sensory modalities engaged in visuo-manual adaptation, was examined in neglect patients before and after prism adaptation. Two separate groups of neglect patients (all of whom exhibited left auditory extinction) underwent prism adaptation: one group (n = 6) received a classical prism treatment ('Prism' group), the other group (n = 6) was submitted to the same procedure, but wore neutral glasses creating no optical shift (placebo 'Control' group). Auditory extinction was assessed by means of a dichotic listening task performed three times: prior to prism exposure (pre-test), upon prism removal (0 h post-test) and 2 h later (2 h post-test). The total number of correct responses, the lateralization index (detection asymmetry between the two ears) and the number of left-right fusion errors were analysed. Our results demonstrate that prism adaptation can improve left auditory extinction, thus revealing transfer of benefit to a sensory modality that is orthogonal to the visual, proprioceptive and motor modalities directly implicated in the visuo-motor adaptive process. The observed benefit was specific to the detection asymmetry between the two ears and did not affect the total number of responses. This indicates a specific effect of prism adaptation on lateralized processes rather than on general arousal. Our results suggest that the effects of prism adaptation can extend to unexposed sensory systems. The bottom-up approach of visuo-motor adaptation appears to interact with higher order brain functions related to multisensory integration and can have beneficial effects on sensory processing in different modalities. These findings should stimulate the development of therapeutic approaches aimed at bypassing the affected sensory processing modality by adapting other sensory modalities.
Is the aligning prism measured with the Mallett unit correlated with fusional vergence reserves?
Conway, Miriam L; Thomas, Jennifer; Subramanian, Ahalya
2012-01-01
The Mallett Unit is a clinical test designed to detect the fixation disparity that is most likely to occur in the presence of a decompensated heterophoria. It measures the associated phoria, which is the "aligning prism" needed to nullify the subjective disparity. The technique has gained widespread acceptance within professions such as optometry, for investigating suspected cases of decompensating heterophoria; it is, however, rarely used by orthoptists and ophthalmologists. The aim of this study was to investigate whether fusional vergence reserves, measured routinely by both orthoptists and ophthalmologists to detect heterophoria decompensation, were correlated with aligning prism (associated phoria) in a normal clinical population. Aligning prism (using the Mallett Unit) and fusional vergence reserves (using a prism bar) were measured in 500 participants (mean 41.63 years; standard deviation 11.86 years) at 40 cm and 6 m. At 40 cm a strong correlation (p<0.001) between base in aligning prism (Exo FD) and positive fusional reserves was found. Of the participants with zero aligning prism 30% had reduced fusional reserves. At 6 m a weak correlation between base out aligning prism (Eso FD) and negative fusional reserves was found to break (p = 0.01) and to recovery (p = 0.048). Of the participants with zero aligning prism 12% reported reduced fusional reserves. For near vision testing, the strong inverse correlation between base in aligning prism (Exo FD) and fusional vergence reserves supports the notion that both measures are indicators of decompensation of heterophoria. For distance vision testing and for those patients reporting zero aligning prism further research is required to determine why the relationship appears to be weak/non-existent?
Epidemiology, genetics, and subtyping of preserved ratio impaired spirometry (PRISm) in COPDGene.
Wan, Emily S; Castaldi, Peter J; Cho, Michael H; Hokanson, John E; Regan, Elizabeth A; Make, Barry J; Beaty, Terri H; Han, MeiLan K; Curtis, Jeffrey L; Curran-Everett, Douglas; Lynch, David A; DeMeo, Dawn L; Crapo, James D; Silverman, Edwin K
2014-08-06
Preserved Ratio Impaired Spirometry (PRISm), defined as a reduced FEV1 in the setting of a preserved FEV1/FVC ratio, is highly prevalent and is associated with increased respiratory symptoms, systemic inflammation, and mortality. Studies investigating quantitative chest tomographic features, genetic associations, and subtypes in PRISm subjects have not been reported. Data from current and former smokers enrolled in COPDGene (n = 10,192), an observational, cross-sectional study which recruited subjects aged 45-80 with ≥10 pack years of smoking, were analyzed. To identify epidemiological and radiographic predictors of PRISm, we performed univariate and multivariate analyses comparing PRISm subjects both to control subjects with normal spirometry and to subjects with COPD. To investigate common genetic predictors of PRISm, we performed a genome-wide association study (GWAS). To explore potential subgroups within PRISm, we performed unsupervised k-means clustering. The prevalence of PRISm in COPDGene is 12.3%. Increased dyspnea, reduced 6-minute walk distance, increased percent emphysema and decreased total lung capacity, as well as increased segmental bronchial wall area percentage were significant predictors (p-value <0.05) of PRISm status when compared to control subjects in multivariate models. Although no common genetic variants were identified on GWAS testing, a significant association with Klinefelter's syndrome (47XXY) was observed (p-value < 0.001). Subgroups identified through k-means clustering include a putative "COPD-subtype", "Restrictive-subtype", and a highly symptomatic "Metabolic-subtype". PRISm subjects are clinically and genetically heterogeneous. Future investigations into the pathophysiological mechanisms behind and potential treatment options for subgroups within PRISm are warranted. Clinicaltrials.gov Identifier: NCT000608764.
NASA Technical Reports Server (NTRS)
Mannucci, A. J.; Anderson, D. N.; Abdu, A. M.
1994-01-01
The Parametrized Real-Time Ionosphere Specification Model (PRISM) is a global ionospheric specification model that can incorporate real-time data to compute accurate electron density profiles. Time series of computed and measured data are compared in this paper. This comparison can be used to suggest methods of optimizing the PRISM adjustment algorithm for TEC data obtained at low altitudes.
Beam splitter and method for generating equal optical path length beams
Qian, Shinan; Takacs, Peter
2003-08-26
The present invention is a beam splitter for splitting an incident beam into first and second beams so that the first and second beams have a fixed separation and are parallel upon exiting. The beam splitter includes a first prism, a second prism, and a film located between the prisms. The first prism is defined by a first thickness and a first perimeter which has a first major base. The second prism is defined by a second thickness and a second perimeter which has a second major base. The film is located between the first major base and the second major base for splitting the incident beam into the first and second beams. The first and second perimeters are right angle trapezoidal shaped. The beam splitter is configured for generating equal optical path length beams.
Compact cross-dispersion device based on a prism and a plane transmission grating
NASA Astrophysics Data System (ADS)
Yang, Qinghua; Wang, Weiqiang
2018-05-01
This paper presents a cross-dispersion prism-grating device using a plane transmission grating attached directly to a prism, which is different from traditional cross-dispersion grating-prism systems that are based on the reflection grating. Unlike conventional direct-vision grism or constant-dispersion grism in which both the prism and grating have the same dispersion direction, for this device the dispersion directions of the prism and grating are different. The analytical expressions for the cross-dispersion of this device are derived in detail and the formulas of the footprint of the dispersed spectra are given. The numerical results and ray-tracing simulations by ZEMAX are shown. The device provides a compact, small-sized and broadband cross-dispersion device used for the medium resolution spectrometer.
Performance analysis of higher mode spoof surface plasmon polariton for terahertz sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Haizi; Tu, Wanli; Zhong, Shuncong, E-mail: zhongshuncong@hotmail.com
2015-04-07
We investigated the spoof surface plasmon polaritons (SSPPs) on 1D grooved metal surface for terahertz sensing of refractive index of the filling analyte through a prism-coupling attenuated total reflection setup. From the dispersion relation analysis and the finite element method-based simulation, we revealed that the dispersion curve of SSPP got suppressed as the filling refractive index increased, which cause the coupling resonance frequency redshifting in the reflection spectrum. The simulated results for testing various refractive indexes demonstrated that the incident angle of terahertz radiation has a great effect on the performance of sensing. Smaller incident angle will result in amore » higher sensitive sensing with a narrower detection range. In the meanwhile, the higher order mode SSPP-based sensing has a higher sensitivity with a narrower detection range. The maximum sensitivity is 2.57 THz/RIU for the second-order mode sensing at 45° internal incident angle. The proposed SSPP-based method has great potential for high sensitive terahertz sensing.« less
NASA Astrophysics Data System (ADS)
Woo, Sungsoo; Kang, Sungsam; Yoon, Changhyeong; Choi, Wonshik
2016-03-01
With the advancement of 3D display technology, 3D imaging of macroscopic objects has drawn much attention as they provide the contents to display. The most widely used imaging methods include a depth camera, which measures time of flight for the depth discrimination, and various structured illumination techniques. However, these existing methods have poor depth resolution, which makes imaging complicated structures a difficult task. In order to resolve this issue, we propose an imaging system based upon low-coherence interferometry and off-axis digital holographic imaging. By using light source with coherence length of 200 micro, we achieved the depth resolution of 100 micro. In order to map the macroscopic objects with this high axial resolution, we installed a pair of prisms in the reference beam path for the long-range scanning of the optical path length. Specifically, one prism was fixed in position, and the other prism was mounted on a translation stage and translated in parallel to the first prism. Due to the multiple internal reflections between the two prisms, the overall path length was elongated by a factor of 50. In this way, we could cover a depth range more than 1 meter. In addition, we employed multiple speckle illuminations and incoherent averaging of the acquired holographic images for reducing the specular reflections from the target surface. Using this newly developed system, we performed imaging targets with multiple different layers and demonstrated imaging targets hidden behind the scattering layers. The method was also applied to imaging targets located around the corner.
Total Internal Reflection Ultrasonic Sensor for Detection of Subsurface Flaws: Proof of Concept
2010-01-01
34 Tv001 Ve group (ray) velocity of the elastic wave X1, X2, X3 crystallographic coordinates x, y, z Descartes ’ coordinates tied to the transducer y0...TeO2 prism. 1.2.1. Orientation of directions and planes of interest with respect to Descartes ’ and Spherical coordinates. 1.2.2. Reflection of the...spect to Descartes ’ and Spherical coordi- nates. , (1.2.1) lili uuv Γ=ρ 2 where ρ is the crystal density and the symmetrical second rank Christoffel
Sensky, Tom; Büchi, Stefan
2016-01-01
PRISM (the Pictorial Representation of Illness and Self Measure) is a novel, simple visual instrument. Its utility was initially discovered serendipitously, but has been validated as a quantitative measure of suffering. Recently, new applications for different purposes, even in non-health settings, have encouraged further exploration of how PRISM works, and how it might be applied. This review will summarise the results to date from applications of PRISM and propose a generic conceptualisation of how PRISM works which is consistent with all these applications. A systematic review, in the form of a qualitative evidence synthesis, was carried out of all available published data on PRISM. Fifty-two publications were identified, with a total of 8254 participants. Facilitated by simple instructions, PRISM has been used with patient groups in a variety of settings and cultures. As a measure of suffering, PRISM has, with few exceptions, behaved as expected according to Eric Cassell's seminal conceptualisation of suffering. PRISM has also been used to assess beliefs about or attitudes to stressful working conditions, interpersonal relations, alcohol consumption, and suicide, amongst others. This review supports PRISM behaving as a visual metaphor of the relationship of objects (eg 'my illness') to a subject (eg 'myself') in a defined context (eg 'my life at the moment'). As a visual metaphor, it is quick to complete and yields personally salient information. PRISM is likely to have wide applications in assessing beliefs, attitudes, and decision-making, because of its properties, and because it yields both quantitative and qualitative data. In medicine, it can serve as a generic patient-reported outcome measure. It can serve as a tool for representational guidance, can be applied to developing strategies visually, and is likely to have applications in coaching, psychological assessment and therapeutic interventions.
Is the Aligning Prism Measured with the Mallett Unit Correlated with Fusional Vergence Reserves?
Conway, Miriam L.; Thomas, Jennifer; Subramanian, Ahalya
2012-01-01
Background The Mallett Unit is a clinical test designed to detect the fixation disparity that is most likely to occur in the presence of a decompensated heterophoria. It measures the associated phoria, which is the “aligning prism” needed to nullify the subjective disparity. The technique has gained widespread acceptance within professions such as optometry, for investigating suspected cases of decompensating heterophoria; it is, however, rarely used by orthoptists and ophthalmologists. The aim of this study was to investigate whether fusional vergence reserves, measured routinely by both orthoptists and ophthalmologists to detect heterophoria decompensation, were correlated with aligning prism (associated phoria) in a normal clinical population. Methodology/Principal Findings Aligning prism (using the Mallett Unit) and fusional vergence reserves (using a prism bar) were measured in 500 participants (mean 41.63 years; standard deviation 11.86 years) at 40 cm and 6 m. At 40 cm a strong correlation (p<0.001) between base in aligning prism (Exo FD) and positive fusional reserves was found. Of the participants with zero aligning prism 30% had reduced fusional reserves. At 6 m a weak correlation between base out aligning prism (Eso FD) and negative fusional reserves was found to break (p = 0.01) and to recovery (p = 0.048). Of the participants with zero aligning prism 12% reported reduced fusional reserves. Conclusions/Significance For near vision testing, the strong inverse correlation between base in aligning prism (Exo FD) and fusional vergence reserves supports the notion that both measures are indicators of decompensation of heterophoria. For distance vision testing and for those patients reporting zero aligning prism further research is required to determine why the relationship appears to be weak/non-existent? PMID:22905174
Stereoacuity as an indicator of prism adaptation.
Momeni-Moghaddam, Hamed; Eperjesi, Frank; Kundart, James; Mostafavi-Nam, Kazem
2014-08-01
The purpose of this study was to determine whether stereoacuity can be used as an indicator of prism adaptation. In particular, we wanted to know whether the time required for stereoacuity to return to the initial level after viewing through a prism can be used to determine the degree of adaptation. Eighteen subjects participated in this study. Stereoacuity and dissociated phoria were determined using the TNO stereotest and the Maddox rod, respectively. Prism vergences were measured using a prism bar. For each participant, prism power equivalent to the blur point of base-in (BI) and base-out (BO) fusional vergence at 40 cm was divided and placed in front of both eyes. At 0, 3, 6, 9 and 12 min after prism introduction, the stereoacuity was measured, and at 0 and 12 min, the heterophoria was measured. The repeated measures ANOVA showed a significant difference between the mean stereoacuity for BI and BO prisms at the different measurement times (p < 0.05). For BO prism, the initial value was different between 0 and 3 min after the prism introduction, whereas for BI prism, a difference in stereoacuity was found between the pre-prism value and the value at 0, 3 and 6 min. The size of the heterophoria with BO and BI prisms was different from 0 to 12 min (p < 0.05). The time required for stereoacuity to return to baseline level was more than 3 min for BO, and more than 6 min for BI prism. In addition, the time required to return to baseline values was not similar for the stereoacuity and heterophoria. The recovery of stereoacuity is slower when adapting to divergence, as when looking from near to far. This implies that stereopsis responds faster to near targets than to distant one, and may precede complete phoria adaptation.
Ultradispersive adaptive prism based on a coherently prepared atomic medium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sautenkov, Vladimir A.; P. N. Lebedev Institute of Physics, Moscow 119991; Li Hebin
2010-06-15
We have experimentally demonstrated an ultra-dispersive optical prism made from a coherently driven Rb atomic vapor. The prism possesses spectral angular dispersion that is 6 orders of magnitude higher than that of a prism made of optical glass; such angular dispersion allows one to spatially resolve light beams with different frequencies separated by a few kilohertz. The prism operates near the resonant frequency of atomic vapor and its dispersion is optically controlled by a coherent driving field.
Large beam deflection using cascaded prism array
NASA Astrophysics Data System (ADS)
Wang, Wei-Chih; Tsui, Chi-Leung
2012-04-01
Endoscopes have been utilize in the medical field to observe the internals of the human body to assist the diagnosis of diseases, such as breathing disorders, internal bleeding, stomach ulcers, and urinary tract infections. Endoscopy is also utilized in the procedure of biopsy for the diagnosis of cancer. Conventional endoscopes suffer from the compromise between overall size and image quality due to the required size of the sensor for acceptable image quality. To overcome the size constraint while maintaining the capture image quality, we propose an electro-optic beam steering device based on thermal-plastic polymer, which has a small foot-print (~5mmx5mm), and can be easily fabricated using conventional hot-embossing and micro-fabrication techniques. The proposed device can be implemented as an imaging device inside endoscopes to allow reduction in the overall system size. In our previous work, a single prism design has been used to amplify the deflection generated by the index change of the thermal-plastic polymer when a voltage is applied; it yields a result of 5.6° deflection. To further amplify the deflection, a new design utilizing a cascading three-prism array has been implemented and a deflection angle to 29.2° is observed. The new design amplifies the beam deflection, while keeping the advantage of simple fabrication made possible by thermal-plastic polymer. Also, a photo-resist based collimator lens array has been added to reduce and provide collimation of the beam for high quality imaging purposes. The collimator is able to collimate the exiting beam at 4 μm diameter for up to 25mm, which potentially allows high resolution image capturing.
ERIC Educational Resources Information Center
Ribeiro, Jair Lúcio Prados
2018-01-01
We only became aware of the existence of bed prism spectacles when a student brought them to the classroom and asked us about how they work. The device proved to be a fertile source of curiosity among the students, and, to be properly understood, it required us to develop a comparison between reflection in a typical mirror and total internal…
Impact of high power and angle of incidence on prism corrections for visual field loss.
Jung, Jae-Hyun; Peli, Eli
2014-01-17
Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice.
Impact of high power and angle of incidence on prism corrections for visual field loss
Jung, Jae-Hyun; Peli, Eli
2014-01-01
Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice. PMID:24497649
Forward and inverse solutions for three-element Risley prism beam scanners.
Li, Anhu; Liu, Xingsheng; Sun, Wansong
2017-04-03
Scan blind zone and control singularity are two adverse issues for the beam scanning performance in double-prism Risley systems. In this paper, a theoretical model which introduces a third prism is developed. The critical condition for a fully eliminated scan blind zone is determined through a geometric derivation, providing several useful formulae for three-Risley-prism system design. Moreover, inverse solutions for a three-prism system are established, based on the damped least-squares iterative refinement by a forward ray tracing method. It is shown that the efficiency of this iterative calculation of the inverse solutions can be greatly enhanced by a numerical differentiation method. In order to overcome the control singularity problem, the motion law of any one prism in a three-prism system needs to be conditioned, resulting in continuous and steady motion profiles for the other two prisms.
Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).
Gao, Hao; Yu, Hengyong; Osher, Stanley; Wang, Ge
2011-11-01
We propose a compressive sensing approach for multi-energy computed tomography (CT), namely the prior rank, intensity and sparsity model (PRISM). To further compress the multi-energy image for allowing the reconstruction with fewer CT data and less radiation dose, the PRISM models a multi-energy image as the superposition of a low-rank matrix and a sparse matrix (with row dimension in space and column dimension in energy), where the low-rank matrix corresponds to the stationary background over energy that has a low matrix rank, and the sparse matrix represents the rest of distinct spectral features that are often sparse. Distinct from previous methods, the PRISM utilizes the generalized rank, e.g., the matrix rank of tight-frame transform of a multi-energy image, which offers a way to characterize the multi-level and multi-filtered image coherence across the energy spectrum. Besides, the energy-dependent intensity information can be incorporated into the PRISM in terms of the spectral curves for base materials, with which the restoration of the multi-energy image becomes the reconstruction of the energy-independent material composition matrix. In other words, the PRISM utilizes prior knowledge on the generalized rank and sparsity of a multi-energy image, and intensity/spectral characteristics of base materials. Furthermore, we develop an accurate and fast split Bregman method for the PRISM and demonstrate the superior performance of the PRISM relative to several competing methods in simulations.
NASA Astrophysics Data System (ADS)
Zhang, Hao; Yuan, Yan; Su, Lijuan; Huang, Fengzhen; Bai, Qing
2016-09-01
The Risley-prism-based light beam steering apparatus delivers superior pointing accuracy and it is used in imaging LIDAR and imaging microscopes. A general model for pointing error analysis of the Risley prisms is proposed in this paper, based on ray direction deviation in light refraction. This model captures incident beam deviation, assembly deflections, and prism rotational error. We derive the transmission matrixes of the model firstly. Then, the independent and cumulative effects of different errors are analyzed through this model. Accuracy study of the model shows that the prediction deviation of pointing error for different error is less than 4.1×10-5° when the error amplitude is 0.1°. Detailed analyses of errors indicate that different error sources affect the pointing accuracy to varying degree, and the major error source is the incident beam deviation. The prism tilting has a relative big effect on the pointing accuracy when prism tilts in the principal section. The cumulative effect analyses of multiple errors represent that the pointing error can be reduced by tuning the bearing tilting in the same direction. The cumulative effect of rotational error is relative big when the difference of these two prism rotational angles equals 0 or π, while it is relative small when the difference equals π/2. The novelty of these results suggests that our analysis can help to uncover the error distribution and aid in measurement calibration of Risley-prism systems.
Kokaly, Raymond F.
2011-01-01
This report describes procedures for installing and using the U.S. Geological Survey Processing Routines in IDL for Spectroscopic Measurements (PRISM) software. PRISM provides a framework to conduct spectroscopic analysis of measurements made using laboratory, field, airborne, and space-based spectrometers. Using PRISM functions, the user can compare the spectra of materials of unknown composition with reference spectra of known materials. This spectroscopic analysis allows the composition of the material to be identified and characterized. Among its other functions, PRISM contains routines for the storage of spectra in database files, import/export of ENVI spectral libraries, importation of field spectra, correction of spectra to absolute reflectance, arithmetic operations on spectra, interactive continuum removal and comparison of spectral features, correction of imaging spectrometer data to ground-calibrated reflectance, and identification and mapping of materials using spectral feature-based analysis of reflectance data. This report provides step-by-step instructions for installing the PRISM software and running its functions.
Sensky, Tom; Büchi, Stefan
2016-01-01
Background PRISM (the Pictorial Representation of Illness and Self Measure) is a novel, simple visual instrument. Its utility was initially discovered serendipitously, but has been validated as a quantitative measure of suffering. Recently, new applications for different purposes, even in non-health settings, have encouraged further exploration of how PRISM works, and how it might be applied. This review will summarise the results to date from applications of PRISM and propose a generic conceptualisation of how PRISM works which is consistent with all these applications. Methods A systematic review, in the form of a qualitative evidence synthesis, was carried out of all available published data on PRISM. Results Fifty-two publications were identified, with a total of 8254 participants. Facilitated by simple instructions, PRISM has been used with patient groups in a variety of settings and cultures. As a measure of suffering, PRISM has, with few exceptions, behaved as expected according to Eric Cassell’s seminal conceptualisation of suffering. PRISM has also been used to assess beliefs about or attitudes to stressful working conditions, interpersonal relations, alcohol consumption, and suicide, amongst others. Discussion This review supports PRISM behaving as a visual metaphor of the relationship of objects (eg ‘my illness’) to a subject (eg ‘myself’) in a defined context (eg ‘my life at the moment’). As a visual metaphor, it is quick to complete and yields personally salient information. PRISM is likely to have wide applications in assessing beliefs, attitudes, and decision-making, because of its properties, and because it yields both quantitative and qualitative data. In medicine, it can serve as a generic patient-reported outcome measure. It can serve as a tool for representational guidance, can be applied to developing strategies visually, and is likely to have applications in coaching, psychological assessment and therapeutic interventions. PMID:27214024
Li, Ping; Zhou, Yong; Zhao, Zongyan; Xu, Qinfeng; Wang, Xiaoyong; Xiao, Min; Zou, Zhigang
2015-08-05
An unprecedented, crystal facet-based CeO2 homojunction consisting of hexahedron prism-anchored octahedron with exposed prism surface of {100} facets and octahedron surface of {111} facets was fabricated through solution-based crystallographic-oriented epitaxial growth. The photocatalysis experiment reveals that growth of the prism arm on octahedron allows to activate inert CeO2 octahedron for an increase in phototocatalytic reduction of CO2 into methane. The pronounced photocatalytic performance is attributed to a synergistic effect of the following three factors: (1) band alignment of the {100} and {111} drives electrons and holes to octahedron and prism surfaces, respectively, aiming to reach the most stable energy configuration and leading to a spatial charge separation for long duration; (2) crystallographic-oriented epitaxial growth of the CeO2 hexahedron prism arm on the octahedron verified by the interfacial lattice fringe provides convenient and fast channels for the photogenerated carrier transportation between two units of homojuntion; (3) different effective mass of electrons and holes on {100} and {111} faces leads to high charge carrier mobility, more facilitating the charge separation. The proposed facet-based homojunction in this work may provide a new concept for the efficient separation and fast transfer of photoinduced charge carriers and enhancement of the photocatalytic performance.
Pasechnyk, Olena V; Hendel, Nataliia V
2018-01-01
Introduction: The development of international legal cooperation in the field of health has largely been driven by the trade interests of states. The aim: The article analyzes the legal regulation of the circulation of medicines through the prism of the law of the World Trade Organization. Materials and methods: Using the historical legal method has allowed to analyze the genesis of legal regulation of the circulation of medicines through the prism of the law of the World Trade Organization. The dialectical method is widely used, in particular, when it comes to the issue of the ratio of market regulation of medicines circulation and public health protection, the formal logic method, in particular, in formulating the general principles, principles and methods of legal regulation in the field of medicines, as well as the systemic method, in particular, in defining the institutional component of legal regulation in the field of medicines. Review: The activities of the WTO include several areas related to health protection: international control over infectious diseases, international legal regulation of food safety (food security), tobacco control, environmental protection, international legal aspects of access and treatment of medicinal and pharmaceutical products, international legal regulation of medical services provision. Conclusions: It is proved that the right to health is a right to access to medicines. However, for many developing countries, it is problematic to obtain patents for the production of necessary medicines or to pay a license fee, which creates a barrier to the realization of the right to health.
The effect of compliant prisms on subduction zone earthquakes and tsunamis
NASA Astrophysics Data System (ADS)
Lotto, Gabriel C.; Dunham, Eric M.; Jeppson, Tamara N.; Tobin, Harold J.
2017-01-01
Earthquakes generate tsunamis by coseismically deforming the seafloor, and that deformation is largely controlled by the shallow rupture process. Therefore, in order to better understand how earthquakes generate tsunamis, one must consider the material structure and frictional properties of the shallowest part of the subduction zone, where ruptures often encounter compliant sedimentary prisms. Compliant prisms have been associated with enhanced shallow slip, seafloor deformation, and tsunami heights, particularly in the context of tsunami earthquakes. To rigorously quantify the role compliant prisms play in generating tsunamis, we perform a series of numerical simulations that directly couple dynamic rupture on a dipping thrust fault to the elastodynamic response of the Earth and the acoustic response of the ocean. Gravity is included in our simulations in the context of a linearized Eulerian description of the ocean, which allows us to model tsunami generation and propagation, including dispersion and related nonhydrostatic effects. Our simulations span a three-dimensional parameter space of prism size, prism compliance, and sub-prism friction - specifically, the rate-and-state parameter b - a that determines velocity-weakening or velocity-strengthening behavior. We find that compliant prisms generally slow rupture velocity and, for larger prisms, generate tsunamis more efficiently than subduction zones without prisms. In most but not all cases, larger, more compliant prisms cause greater amounts of shallow slip and larger tsunamis. Furthermore, shallow friction is also quite important in determining overall slip; increasing sub-prism b - a enhances slip everywhere along the fault. Counterintuitively, we find that in simulations with large prisms and velocity-strengthening friction at the base of the prism, increasing prism compliance reduces rather than enhances shallow slip and tsunami wave height.
Picardi, Angelo; Tarolla, Emanuele; de Girolamo, Giovanni; Gigantesco, Antonella; Neri, Giovanni; Rossi, Elisabetta; Biondi, Massimo
2014-01-01
This article describes the activities of a project aimed at developing a system of process and process/outcome indicators suitable to monitor over time the quality of psychiatric care of Italian inpatient and residential psychiatric facilities. This system, named PRISM (Process Indicator System for Mental health), was developed by means of a standardized evaluation made by a panel of experts and a consecutive pilot study in 17 inpatient and 13 residential psychiatric facilities. A total of 28 indicators were selected from a set of 251 candidate indicators developed by the most relevant and qualified Italian and international authorities. These indicators are derived by data from medical records and information about characteristics of facilities, and they cover processes of care, operational equipment of facilities, staff training and working, relationships with external agencies, and sentinel events. The procedure followed for the development of the indicator system was reliable and innovative. The data collected from the pilot study suggested a favourable benefit-cost ratio between the workload associated with regular use of the indicators into the context of daily clinical activities and the advantages related to the information gathered through regular use of the indicators. CONCLUSIONS.:The PRISM system provides additional information about the healthcare processes with respect to the information gathered via routine information systems, and it might prove useful for both continuous quality improvement programs and health services research.
Prism adaptation does not alter object-based attention in healthy participants.
Bultitude, Janet H; List, Alexandra; Aimola Davies, Anne M
2013-01-01
Hemispatial neglect ('neglect') is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the proposal that prism adaptation may only perturb cognitive functions for which normal baseline performance is already biased.
Prism adaptation does not alter object-based attention in healthy participants
Bultitude, Janet H.
2013-01-01
Hemispatial neglect (‘neglect’) is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the proposal that prism adaptation may only perturb cognitive functions for which normal baseline performance is already biased. PMID:24715960
An optofluidic prism tuned by two laminar flows.
Xiong, S; Liu, A Q; Chin, L K; Yang, Y
2011-06-07
This paper presents a tunable optofluidic prism based on the configuration of two laminar flow streams with different refractive indices in a triangular chamber. The chambers with 70° and 90° apex angles are designed based on simulation results, which provide the optimum working range and avoid recirculating flows in the chambers. In addition, a hydrodynamic model has been developed to predict the tuning of the prisms by the variation in the flow rates. Prisms with different refractive indices are realized using benzyl alcohol and deionized (DI) water as the inner liquids, respectively. The mixture of ethylene glycol and DI water with an effective refractive index matched to that of the microchannel is used as the outer liquid. The apex angle of the prism is tuned from 75° to 135° by adjusting the ratio of the two flow rates. Subsequently, the deviation angle of the output light beam is tuned from -13.5° to 22°. One of the new features of this optofluidic prism is its capability to transform from a symmetric to an asymmetric prism with the assistance of a third flow. Two optical behaviours have been performed using the optofluidic prism. First, parallel light beam scanning is achieved with a constant deviation angle of 10° and a tuning range of 60 μm using the asymmetric prism. The detected output light intensity is increased by 65.7%. Second, light dispersion is experimentally demonstrated using 488-nm and 633-nm laser beams. The two laser beams become distinguishable with a deviation angle difference of 2.5° when the apex angle of the prism reaches 116°.
Vertical gaze angle: absolute height-in-scene information for the programming of prehension.
Gardner, P L; Mon-Williams, M
2001-02-01
One possible source of information regarding the distance of a fixated target is provided by the height of the object within the visual scene. It is accepted that this cue can provide ordinal information, but generally it has been assumed that the nervous system cannot extract "absolute" information from height-in-scene. In order to use height-in-scene, the nervous system would need to be sensitive to ocular position with respect to the head and to head orientation with respect to the shoulders (i.e. vertical gaze angle or VGA). We used a perturbation technique to establish whether the nervous system uses vertical gaze angle as a distance cue. Vertical gaze angle was perturbed using ophthalmic prisms with the base oriented either up or down. In experiment 1, participants were required to carry out an open-loop pointing task whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. In experiment 2, the participants reached to grasp an object under closed-loop viewing conditions whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. Experiment 1 and 2 provided clear evidence that the human nervous system uses vertical gaze angle as a distance cue. It was found that the weighting attached to VGA decreased with increasing target distance. The weighting attached to VGA was also affected by the discrepancy between the height of the target, as specified by all other distance cues, and the height indicated by the initial estimate of the position of the supporting surface. We conclude by considering the use of height-in-scene information in the perception of surface slant and highlight some of the complexities that must be involved in the computation of environmental layout.
Development/Modernization of an Advanced Non-Light Water Reactor Probabilistic Risk Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henneke, Dennis W.; Robinson, James
In 2015, GE Hitachi Nuclear Energy (GEH) teamed with Argonne National Laboratory (Argonne) to perform Research and Development (R&D) of next-generation Probabilistic Risk Assessment (PRA) methodologies for the modernization of an advanced non-Light Water Reactor (non-LWR) PRA. This effort built upon a PRA developed in the early 1990s for GEH’s Power Reactor Inherently Safe Module (PRISM) Sodium Fast Reactor (SFR). The work had four main tasks: internal events development modeling the risk from the reactor for hazards occurring at-power internal to the plant; an all hazards scoping review to analyze the risk at a high level from external hazards suchmore » as earthquakes and high winds; an all modes scoping review to understand the risk at a high level from operating modes other than at-power; and risk insights to integrate the results from each of the three phases above. To achieve these objectives, GEH and Argonne used and adapted proven PRA methodologies and techniques to build a modern non-LWR all hazards/all modes PRA. The teams also advanced non-LWR PRA methodologies, which is an important outcome from this work. This report summarizes the project outcomes in two major phases. The first phase presents the methodologies developed for non-LWR PRAs. The methodologies are grouped by scope, from Internal Events At-Power (IEAP) to hazards analysis to modes analysis. The second phase presents details of the PRISM PRA model which was developed as a validation of the non-LWR methodologies. The PRISM PRA was performed in detail for IEAP, and at a broader level for hazards and modes. In addition to contributing methodologies, this project developed risk insights applicable to non-LWR PRA, including focus-areas for future R&D, and conclusions about the PRISM design.« less
Farias, J A; Frutos-Vivar, F; Casado Flores, J; Siaba, A; Retta, A; Fernández, A; Baltodano, A; Ko, I J; Johnson, M; Esteban, A
2006-12-01
Identify factors associated with the survival of pediatric patients who are submitted to mechanical ventilation (MV) for more than 12 hours. International prospective cohort study. It was performed between April 1 and May 31 1999. All patients were followed-up during 28 days or discharge to pediatric intensive care unit (PICU). 36 PICUs from 7 countries. A total of 659 ventilated patients were enrolled but 15 patients were excluded because their vital status was unknown on discharge. Overall in-UCIP mortality rate was 15,6%. Recursive partitioning and logistic regression were used and an outcome model was constructed. The variables significantly associated with mortality were: peak inspiratory pressure (PIP), acute renal failure (ARF), PRISM score and severe hypoxemia (PaO2/FiO2 < 100). The subgroup with best outcome (mortality 7%) included patients who were ventilated with a PIP < 35 cmH2O, without ARF, or PaO2/FiO2 > 100 and PRISM < 27. In patients with a mean PaO2/FiO2 < 100 during MV mortality increased to 26% (OR: 4.4; 95% CI 2.0 to 9.4). Patients with a PRISM score > 27 on admission to PICU had a mortality of 43% (OR: 9.6; 95% CI 4,2 to 25,8). Development of acute renal failure was associated with a mortality of 50% (OR: 12.7; 95% CI 6.3 to 25.7). Finally, the worst outcome (mortality 58%) was for patients with a mean PIP >/= 35 cmH2O (OR 17.3; 95% CI 8.5 to 36.3). In a large cohort of mechanically ventilated pediatric patients we found that severity of illness at admission, high mean PIP, development of acute renal failure and severe hypoxemia over the course of MV were the factors associated with lower survival rate.
NASA Technical Reports Server (NTRS)
Pishnyak, Oleg; Kreminska, Lyubov; Laventovich, Oleg D.; Pouch, John J.; Miranda, Felix A.; Winker, Bruce K.
2004-01-01
We describe digital beam deflectors (DBDs) based on liquid crystals. Each stage of the device comprises a polarization rotator and a birefringent prism deflector. The birefringent prism deflects the beam by an angle that depends on polarization of the incident beam. The prism can be made of the uniaxial smectic A (SmA) liquid crystal (LC) or a solid crystal such as yttrium orthovanadate (YVO4). SmA prisms have high birefringence and can be constructed in a variety of shapes, including single prisms and prismatic blazed gratings of different angles and profiles. We address the challenges of uniform alignment of SmA, such as elimination of focal conic domains. Rotation of linear polarization is achieved by an electrically switched twisted nematic (TN) cell. A DBD composed of N rotator-deflector pairs steers the beam into 2(sup N) directions. As an example, we describe a four-stage DBD deflecting normally incident laser beam within the range of +/- 56 mrad with 8 mrad steps. Redirection of the beam is achieved by switching the TN cells.
Two-photon laser scanning microscopy with electrowetting-based prism scanning
Supekar, Omkar D.; Ozbay, Baris N.; Zohrabi, Mo; Nystrom, Philip D.; Futia, Gregory L.; Restrepo, Diego; Gibson, Emily A.; Gopinath, Juliet T.; Bright, Victor M.
2017-01-01
Laser scanners are an integral part of high resolution biomedical imaging systems such as confocal or 2-photon excitation (2PE) microscopes. In this work, we demonstrate the utility of electrowetting on dielectric (EWOD) prisms as a lateral laser-scanning element integrated in a conventional 2PE microscope. To the best of our knowledge, this is the first such demonstration for EWOD prisms. EWOD devices provide a transmissive, low power consuming, and compact alternative to conventional adaptive optics, and hence this technology has tremendous potential. We demonstrate 2PE microscope imaging of cultured mouse hippocampal neurons with a FOV of 130 × 130 μm2 using EWOD prism scanning. In addition, we show simulations of the optical system with the EWOD prism, to evaluate the effect of propagating a Gaussian beam through the EWOD prism on the imaging quality. Based on the simulation results a beam size of 0.91 mm full width half max was chosen to conduct the imaging experiments, resulting in a numerical aperture of 0.17 of the imaging system. PMID:29296477
NASA Astrophysics Data System (ADS)
Boston, B.; Moore, G. F.; Jurado, M. J.; Sone, H.; Tobin, H. J.; Saffer, D. M.; Hirose, T.; Toczko, S.; Maeda, L.
2014-12-01
The deeper, inner parts of active accretionary prisms have been poorly studied due the lack of drilling data, low seismic image quality and typically thick overlying sediments. Our project focuses on the interior of the Nankai Trough inner accretionary prism using deep scientific drilling and a 3D seismic cube. International Ocean Discovery Program (IODP) Expedition 348 extended the existing riser hole to more than 3000 meters below seafloor (mbsf) at Site C0002. Logging while drilling (LWD) data included gamma ray, resistivity, resistivity image, and sonic logs. LWD analysis of the lower section revealed on the borehole images intense deformation characterized by steep bedding, faults and fractures. Bedding plane orientations were measured throughout, with minor gaps at heavily deformed zones disrupting the quality of the resistivity images. Bedding trends are predominantly steeply dipping (60-90°) to the NW. Interpretation of fractures and faults in the image log revealed the existence of different sets of fractures and faults and variable fracture density, remarkably high at fault zones. Gamma ray, resistivity and sonic logs indicated generally homogenous lithology interpretation along this section, consistent with the "silty-claystone" predominant lithologies described on cutting samples. Drops in sonic velocity were observed at the fault zones defined on borehole images. Seismic reflection interpretation of the deep faults in the inner prism is exceedingly difficult due to a strong seafloor multiple, high-angle bedding dips, and low frequency of the data. Structural reconstructions were employed to test whether folding of seismic horizons in the overlying forearc basin could be from an interpreted paleothrust within the inner prism. We used a trishear-based restoration to estimate fault slip on folded horizons landward of C0002. We estimate ~500 m of slip from a steeply dipping deep thrust within the last ~0.9 Ma. Folding is not found in the Kumano sediments near C0002, where normal faults and tilting dominate the modern basin deformation. Both logging and seismic are consistent in characterizing a heavily deformed inner prism. Most of this deformation must have occurred during or before formation of the overlying modern Kumano forearc basin sediments.
NASA Astrophysics Data System (ADS)
Nguyen, Minh-Hang; Chu, Thi-Xuan; Nguyen, Long; Nguyen, Hai-Binh; Lee, Chun-Wei; Tseng, Fan-Gang; Chen, Te-Chang; Lee, Ming-Chang
2016-11-01
Fabrication of three-dimensional (3D) SU-8 (an epoxy-based negative photoresist from MicroChem) prisms as low-loss couplers for interconnection between optical components, particularly optical fibers and silicon-on-isolator waveguides (SOI WGs), which have mismatched mode sizes, has been investigated. With an interfacial structure formed by a 3D SU-8 prism partly overlaying an SOI WG end with a portion of buried oxide (BOX) removed under the interface, low-loss coupling is ensured and the transmission efficiency can reach 70%. To fabricate these 3D SU-8 prisms, a simple method with two photolithography steps was used for SU-8 hinges and CYTOP (an amorphous fluoropolymer from AGC Chemicals) prism windows, with mild soft and hard bakes, to define the prism profiles with diluted SU-8 filled in the CYTOP prism windows. A buffered oxide etchant is used to remove BOX parts under the interfaces. Some of the fabricated structures were tested, demonstrating the contribution of overlaying SU-8 prisms to the transmission efficiency of optical interconnections between fibers and SOI WGs.
Narrow groove plasmonic nano-gratings for surface plasmon resonance sensing
Dhawan, Anuj; Canva, Michael; Vo-Dinh, Tuan
2011-01-01
We present a novel surface plasmon resonance (SPR) configuration based on narrow groove (sub-15 nm) plasmonic nano-gratings such that normally incident radiation can be coupled into surface plasmons without the use of prism-coupling based total internal reflection, as in the classical Kretschmann configuration. This eliminates the angular dependence requirements of SPR-based sensing and allows development of robust miniaturized SPR sensors. Simulations based on Rigorous Coupled Wave Analysis (RCWA) were carried out to numerically calculate the reflectance - from different gold and silver nano-grating structures - as a function of the localized refractive index of the media around the SPR nano-gratings as well as the incident radiation wavelength and angle of incidence. Our calculations indicate substantially higher differential reflectance signals, on localized change of refractive index in the narrow groove plasmonic gratings, as compared to those obtained from conventional SPR-based sensing systems. Furthermore, these calculations allow determination of the optimal nano-grating geometric parameters - i. e. nanoline periodicity, spacing between the nanolines, as well as the height of the nanolines in the nano-grating - for highest sensitivity to localized change of refractive index, as would occur due to binding of a biomolecule target to a functionalized nano-grating surface. PMID:21263620
Asymmetric transmission in prisms using structures and materials with isotropic-type dispersion.
Gundogdu, Funda Tamara; Serebryannikov, Andriy E; Cakmak, A Ozgur; Ozbay, Ekmel
2015-09-21
It is demonstrated that strong asymmetry in transmission can be obtained at the Gaussian beam illumination for a single prism based on a photonic crystal (PhC) with isotropic-type dispersion, as well as for its analog made of a homogeneous material. Asymmetric transmission can be realized with the aid of refraction at a proper orientation of the interfaces and wedges of the prism, whereas neither contribution of higher diffraction orders nor anisotropic-type dispersion is required. Furthermore, incidence toward a prism wedge can be used for one of two opposite directions in order to obtain asymmetry. Thus, asymmetric transmission is a general property of the prism configurations, which can be obtained by using simple geometries and quite conventional materials. The obtained results show that strong asymmetry can be achieved in PhC prisms with (nearly) circular shape of equifrequency dispersion contours, in both cases associated with the index of refraction 0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tillman, Karl A.; Thapa, Rajesh; Knabe, Kevin
2009-12-20
The frequency comb from a prism-based Cr:forsterite laser has been frequency stabilized using intracavity prism insertion and pump power modulation. Absolute frequency measurements of a CW fiber laser stabilized to the P(13) transition of acetylene demonstrate a fractional instability of {approx}2x10{sup -11} at a 1 s gate time, limited by a commercial Global Positioning System (GPS)-disciplined rubidium oscillator. Additionally, absolute frequency measurements made simultaneously using a second frequency comb indicate relative instabilities of 3x10{sup -12} for both combs for a 1 s gate time. Estimations of the carrier-envelope offset frequency linewidth based on relative intensity noise and the response dynamicsmore » of the carrier-envelope offset to pump power changes confirm the observed linewidths.« less
A study on suppressing transmittance fluctuations for air-gapped Glan-type polarizing prisms
NASA Astrophysics Data System (ADS)
Zhang, Chuanfa; Li, Dailin; Zhu, Huafeng; Li, Chuanzhi; Jiao, Zhiyong; Wang, Ning; Xu, Zhaopeng; Wang, Xiumin; Song, Lianke
2018-05-01
Light intensity transmittance is a key parameter for the design of polarizing prisms, while sometimes its experimental curves based on spatial incident angle presents periodical fluctuations. Here, we propose a novel method for completely suppressing these fluctuations via setting a glued error angle in the air gap of Glan-Taylor prisms. The proposal consists of: an accurate formula of the intensity transmittance for Glan-Taylor prisms, a numerical simulation and a contrast experiment of Glan-Taylor prisms for analyzing the causes of the fluctuations, and a simple method for accurately measuring the glued error angle. The result indicates that when the setting glued error angle is larger than the critical angle for a certain polarizing prism, the fluctuations can be completely suppressed, and a smooth intensity transmittance curve can be obtained. Besides, the critical angle in the air gap for suppressing the fluctuations is decreased with the increase of beam spot size. This method has the advantage of having less demand for the prism position in optical systems.
Design of a multi-channel free space optical interconnection component
NASA Astrophysics Data System (ADS)
Jia, Da-Gong; Zhang, Pei-Song; Jing, Wen-Cai; Tan, Jun; Zhang, Hong-Xia; Zhang, Yi-Mo
2008-11-01
A multi-channel free space optical interconnection component, fiber optic rotary joint, was designed using a Dove prism. When the Dove prism is rotated an angle of α around the longitudinal axis, the image rotates an angle of 2 α. The optical interconnection component consists of the signal transmission system, Dove prim and driving mechanism. The planetary gears are used to achieve the speed ratio of 2:1 between the total optical interconnection component and the Dove prism. The C-lenses are employed to couple different optical signals in the signal transmission system. The coupling loss between the receiving fiber of stationary part and the transmitting fiber of rotary part is measured.
Sanford, Ward E.; Nelms, David L.; Pope, Jason P.; Selnick, David L.
2012-01-01
This study by the U.S. Geological Survey, prepared in cooperation with the Virginia Department of Environmental Quality, quantifies the components of the hydrologic cycle across the Commonwealth of Virginia. Long-term, mean fluxes were calculated for precipitation, surface runoff, infiltration, total evapotranspiration (ET), riparian ET, recharge, base flow (or groundwater discharge) and net total outflow. Fluxes of these components were first estimated on a number of real-time-gaged watersheds across Virginia. Specific conductance was used to distinguish and separate surface runoff from base flow. Specific-conductance data were collected every 15 minutes at 75 real-time gages for approximately 18 months between March 2007 and August 2008. Precipitation was estimated for 1971–2000 using PRISM climate data. Precipitation and temperature from the PRISM data were used to develop a regression-based relation to estimate total ET. The proportion of watershed precipitation that becomes surface runoff was related to physiographic province and rock type in a runoff regression equation. Component flux estimates from the watersheds were transferred to flux estimates for counties and independent cities using the ET and runoff regression equations. Only 48 of the 75 watersheds yielded sufficient data, and data from these 48 were used in the final runoff regression equation. The base-flow proportion for the 48 watersheds averaged 72 percent using specific conductance, a value that was substantially higher than the 61 percent average calculated using a graphical-separation technique (the USGS program PART). Final results for the study are presented as component flux estimates for all counties and independent cities in Virginia.
A metasurface-based prism analogue for terahertz rainbow spectrum manipulation
NASA Astrophysics Data System (ADS)
Zheng, Shen; Li, Chao; Li, Shichao; Zhang, Xiaojuan; Fang, Guangyou
2017-06-01
Optical prisms can spread compound light spatially into a rainbow and have widespread applications in spectroscopy and imaging. Limited by the natural materials as well as technologies, there has been no natural counterpart of the optical prism that works in the Terahertz (THz) band so far. In this letter, a THz prism analogue based on metasurfaces working in the transmission diffraction mechanism is first proposed to generate the THz rainbow spectrum. The physics of different modes excited by the interaction between the incident wave and the metasurface is investigated in theory and simulation. A coherent enhancement method was developed to improve the mode competition of the rainbow spectrum over other unwanted leaky modes to guarantee the high transfer efficiency of the wavelength dependent transmission diffraction. The experimental results show that the prism analogue can spread the incident spectrum from 0.15 to 0.22 THz in an angular scope of about 30.8° with comparatively high transferring efficiency.
Brooks, C W; Riley, H D
1994-06-01
Success in fitting progressive addition lenses is dependent upon the accurate placement of the progressive zone. Both eyes must track simultaneously within the boundary of the progressive corridor. Vertical prism will displace the wearer's lines of sight and consequently eye position. Because fitting heights are measured using an empty frame, subjects with vertical phorias usually will fuse, and not show the vertical differences in pupil heights during the measuring process. Therefore, when prescriptions contain vertical prism one must consider the changes in measured fitting heights that will occur once the lenses are placed in the frame. Fitting heights must be altered approximately 0.3 mm for each vertical prism diopter prescribed. The fitting height adjustment is opposite from the base direction of the prescribed prism. An explanation of the effect of prescribed horizontal prism on monocular interpupillary distance (PD) measurements is also included.
Accurate geometrical optics model for single-lens stereovision system using a prism.
Cui, Xiaoyu; Lim, Kah Bin; Guo, Qiyong; Wang, DaoLei
2012-09-01
In this paper, we proposed a new method for analyzing the image formation of a prism. The prism was considered as a single optical system composed of some planes. By analyzing each plane individually and then combining them together, we derived a transformation matrix which can express the relationship between an object point and its image by the refraction of a prism. We also explained how to use this matrix for epipolar geometry and three-dimensional point reconstruction. Our method is based on optical geometry and could be used in a multiocular prism. Experimentation results are presented to prove the accuracy of our method is better than former researchers' and is comparable with that of the multicamera stereovision system.
Cavity Enhanced Absorption Spectroscopy Using a Broadband Prism Cavity and a Supercontinuum Source
NASA Astrophysics Data System (ADS)
Johnston, Paul S.; Lehmann, Kevin K.
2009-06-01
The multiplex advantage of current cavity enhanced spectrometers is limited by the high reflectivity bandwidth of the mirrors used to construct the high finesse cavity. Previously, we reported the design and construction of a new spectrometer that circumvents this limitation by utilizing Brewster^{,}s angle prism retroreflectors. The prisms, made from fused silica and combined with a supercontinuum source generated by pumping a highly nonlinear photonic crystal fiber, yields a spectral window ranging from 500 nm to 1750 nm. Recent progress in the instruments development will be discussed, including work on modeling the prism cavity losses, alternative prism material for use in the UV and mid-IR spectral regions, and a new high power supercontinuum source based on mode-locked picosecond laser.
Development of low cost and accurate homemade sensor system based on Surface Plasmon Resonance (SPR)
NASA Astrophysics Data System (ADS)
Laksono, F. D.; Supardianningsih; Arifin, M.; Abraha, K.
2018-04-01
In this paper, we developed homemade and computerized sensor system based on Surface Plasmon Resonance (SPR). The developed systems consist of mechanical system instrument, laser power sensor, and user interface. The mechanical system development that uses anti-backlash gear design was successfully able to enhance the angular resolution angle of incidence laser up to 0.01°. In this system, the laser detector acquisition system and stepper motor controller utilizing Arduino Uno which is easy to program, flexible, and low cost, was used. Furthermore, we employed LabView’s user interface as the virtual instrument for facilitating the sample measurement and for transforming the data recording directly into the digital form. The test results using gold-deposited half-cylinder prism showed the Total Internal Reflection (TIR) angle of 41,34°± 0,01° and SPR angle of 44,20°± 0,01°, respectively. The result demonstrated that the developed system managed to reduce the measurement duration and data recording errors caused by human error. Also, the test results also concluded that the system’s measurement is repeatable and accurate.
Endotoxin removal by radio frequency gas plasma (glow discharge)
NASA Astrophysics Data System (ADS)
Poon, Angela
2011-12-01
Contaminants remaining on implantable medical devices, even following sterilization, include dangerous fever-causing residues of the outer lipopolysaccharide-rich membranes of Gram-negative bacteria such as the common gut microorganism E. coli. The conventional method for endotoxin removal is by Food & Drug Administration (FDA)-recommended dry-heat depyrogenation at 250°C for at least 45 minutes, an excessively time-consuming high-temperature technique not suitable for low-melting or heat-distortable biomaterials. This investigation evaluated the mechanism by which E. coli endotoxin contamination can be eliminated from surfaces during ambient temperature single 3-minute to cumulative 15-minute exposures to radio-frequency glow discharge (RFGD)-generated residual room air plasmas activated at 0.1-0.2 torr in a 35MHz electrodeless chamber. The main analytical technique for retained pyrogenic bio-activity was the Kinetic Chromogenic Limulus Amebocyte Lysate (LAL) Assay, sufficiently sensitive to document compliance with FDA-required Endotoxin Unit (EU) titers less than 20 EU per medical device by optical detection of enzymatic color development corresponding to < 0.5 EU/ml in sterile water extracts of each device. The main analytical technique for identification of chemical compositions, amounts, and changes during sequential reference Endotoxin additions and subsequent RFGD-treatment removals from infrared (IR)-transparent germanium (Ge) prisms was Multiple Attenuated Internal Reflection (MAIR) infrared spectroscopy sensitive to even monolayer amounts of retained bio-contaminant. KimaxRTM 60 mm x 15 mm and 50mm x 15mm laboratory glass dishes and germanium internal reflection prisms were inoculated with E. coli bacterial endotoxin water suspensions at increments of 0.005, 0.05, 0.5, and 5 EU, and characterized by MAIR-IR spectroscopy of the dried residues on the Ge prisms and LAL Assay of sterile water extracts from both glass and Ge specimens. The Ge prism MAIR-IR measurements were repeated after employing 3-minute RFGD treatments sequentially for more than 10 cycles to observe removal of deposited matter that correlated with diminished EU titers. The results showed that 5 cycles, for a total exposure time of 15 minutes to low-temperature gas plasma, was sufficient to reduce endotoxin titers to below 0.05 EU/ml, and correlated with concurrent reduction of major endotoxin reference standard absorption bands at 3391 cm-1, 2887 cm-1, 1646 cm -1 1342 cm-1, and 1103 cm-1 to less than 0.05 Absorbance Units. Band depletion varied from 15% to 40% per 3-minute cycle of RFGD exposure, based on peak-to-peak analyses. In some cases, 100% of all applied biomass was removed within 5 sequential 3-minute RFGD cycles. The lipid ester absorption band expected at 1725 cm-1 was not detectable until after the first RFGD cycle, suggesting an unmasking of the actual bacterial endotoxin membrane induced within the gas plasma environment. Future work must determine the applicability of this low-temperature, quick depyrogenation process to medical devices of more complicated geometry than the flat surfaces tested here.
Engaging Students in GeoPRISMS Science Planning: Preparing the Leaders of Tomorrow
NASA Astrophysics Data System (ADS)
Henning, A. T.; Benoit, M. H.; Marshall, J.; Goodliffe, A. M.; Morgan, J. K.; Bopp, C. J.
2011-12-01
GeoPRISMS is the legacy of the NSF MARGINS Program. It is a new decadal program, funded by NSF, committed to the amphibious study of the origin and evolution of continental margins through interdisciplinary, community-based investigations. MARGINS and GeoPRISMS have had notable success in fostering this team-based approach in graduate students who then continue on to become GeoPRISMS PIs. GeoPRISMS is enhancing its student outreach efforts through the development of a student symposium program, in which graduate students are invited to be more active participants in GeoPRISMS workshops, and are provided with valuable background and reference materials to enable them. This approach has been applied and updated at four GeoPRISMS workshops so far: two implementation workshops and two science planning workshops. Graduate students participated in the GeoPRISMS Rift Initiation and Evolution (RIE) implementation workshop in November 2010 and the Subduction Cycles and Deformation (SCD) workshop in January 2011, contributing to the overall design of the GeoPRISMS research program, and the selection of primary sites for study. In addition to participating in the regular meeting activities, students gave "pop-up" presentations to summarize their research and poster presentations and also worked together to develop their own draft implementation plan that was presented to the larger audience. Students responded positively to the experience of drafting their own implementation plans, which fostered a sense of community among participants and created an environment in which students felt comfortable speaking up during the meeting. Scientists attending the workshops were impressed by the students' draft implementation plans, as well as their work ethic and enthusiasm, and felt they made a very positive contribution to the workshops. Student feedback suggested providing students with a better understanding of the main scientific questions addressed at the meeting, as well as possible career paths. The sequestration of students during the workshop also raised concerns that they missed opportunities for broader community interactions. In Fall 2011, students participated in two symposia associated with the GeoPRISMS Alaska and Eastern North American Margin primary site planning workshops. The fall symposia followed a different model based on feedback from the first two workshops. A full day of activities took place prior to the workshop, including short presentations by experts in the field to provide background, a half-day field trip to enhance cohort-building, and student-only poster sessions and discussions. This approach allowed the students to participate fully in the meeting itself, with a stronger base of knowledge about the workshop topics and a larger network of colleagues.
Gómez-Moya, Rosinna; Díaz, Rosalinda; Fernandez-Ruiz, Juan
2016-04-01
Different processes are involved during visuomotor learning, including an error-based procedural and a strategy based cognitive mechanism. Our objective was to analyze if the changes in the adaptation or the aftereffect components of visuomotor learning measured across development, reflected different maturation rates of the aforementioned mechanisms. Ninety-five healthy children aged 4-12years and a group of young adults participated in a wedge prism and a dove prism throwing task, which laterally displace or horizontally reverse the visual field respectively. The results show that despite the age-related differences in motor control, all children groups adapted in the error-based wedge prisms condition. However, when removing the prism, small children showed a slower aftereffects extinction rate. On the strategy-based visual reversing task only the older children group reached adult-like levels. These results are consistent with the idea of different mechanisms with asynchronous maturation rates participating during visuomotor learning. Copyright © 2016 Elsevier B.V. All rights reserved.
The optimum content of rubber ash in concrete: flexural strength
NASA Astrophysics Data System (ADS)
Senin, M. S.; Shahidan, S.; Shamsuddin, S. M.; Ariffin, S. F. A.; Othman, N. H.; Rahman, R.; Khalid, F. S.; Nazri, F. M.
2017-11-01
Discarded scrap tyres have become one of the major environmental problems nowadays. Several studies have been carried out to reuse waste tires as an additive or sand replacement in concrete with appropriate percentages of tire rubber, called as rubberized concrete to solve this problem. The main objectives of this study are to investigate the flexural strength performance of concrete when adding the rubber ash and also to analyse the optimum content of rubber ash in concrete prisms. The performance total of 30 number of concrete prisms in size of 100mm x 100mm x 500 mm were investigated, by partially replacement of rubber ash with percentage of 0%, 3%, 5%, 7% and 9% from the volume of the sand. The flexural strength is increased when percentage of rubber ash is added 3% from control concrete prism, RA 0 for both concrete prism age, 7 days and 28 days with value 1.21% and 0.976% respectively. However, for RA 5, RA 7 and RA 9, the flexural strength was decreased compared to the control for both age, 7 days and 28 days. In conclusion, 3% is the optimum content of rubber ash in concrete prism for both concrete age
An ultrashort throw ratio projection lens design based on a catadioptric structure
NASA Astrophysics Data System (ADS)
Wang, Hsiu-Cheng; Pan, Jui-Wen
2018-07-01
In this paper, we present a rotational symmetry for an ultrashort throw (UST) lens with offset field. The UST lens has a throw ratio of 0.23 and a total track of 195 mm. The optical elements of the UST lens are comprised of two parts. First, a catadioptric projection lens where the catadioptric function permits reaching an ultrashort throw ratio, short total track, while at the same time requiring fewer lens elements. The second part is a collimating lens which takes advantage of the telecentric condition to generate uniform total internal reflection (TIR) in the TIR prism. With this design, an effective focal length of -1.96 mm and a f-number of 2.4 can be obtained. The root mean square spot size and lateral colour of all fields are smaller than one pixel in size. The maximum optical distortion of -0.97% and TV distortion of 0.2% are acceptable. In terms of image quality, the modulation transfer function (MTF) values for all fields are above 0.65 at 0.245 line pairs/mm. Even when the tolerance error is considered, the MTF values for all fields are still above 0.3. The suitability of the novel UST lens design for projection applications is discussed.
Design of airborne imaging spectrometer based on curved prism
NASA Astrophysics Data System (ADS)
Nie, Yunfeng; Xiangli, Bin; Zhou, Jinsong; Wei, Xiaoxiao
2011-11-01
A novel moderate-resolution imaging spectrometer spreading from visible wavelength to near infrared wavelength range with a spectral resolution of 10 nm, which combines curved prisms with the Offner configuration, is introduced. Compared to conventional imaging spectrometers based on dispersive prism or diffractive grating, this design possesses characteristics of small size, compact structure, low mass as well as little spectral line curve (smile) and spectral band curve (keystone or frown). Besides, the usage of compound curved prisms with two or more different materials can greatly reduce the nonlinearity inevitably brought by prismatic dispersion. The utilization ratio of light radiation is much higher than imaging spectrometer of the same type based on combination of diffractive grating and concentric optics. In this paper, the Seidel aberration theory of curved prism and the optical principles of Offner configuration are illuminated firstly. Then the optical design layout of the spectrometer is presented, and the performance evaluation of this design, including spot diagram and MTF, is analyzed. To step further, several types of telescope matching this system are provided. This work provides an innovational perspective upon optical system design of airborne spectral imagers; therefore, it can offer theoretic guide for imaging spectrometer of the same kind.
A Holographic Prism Based on Photo-Thermo-Refractive Glass: Requirements and Possibilities
NASA Astrophysics Data System (ADS)
Angervaks, A. E.; Gorokhovskii, K. S.; Granovskii, V. A.; Van Bac, Doan; Ivanov, S. A.; Okun', R. A.; Nikonorov, N. V.; Ryskin, A. I.
2017-12-01
A technology for multivalued holographic measurement of a plane angle—a holographic prism, which serves as the basis for a device for calibrating the testing tools for navigational equipment under rolling— has been developed. The holographic prism is a miniature sample of photosensitive material, which contains a system of superimposed holographic gratings, and a laser the radiation of which passes through gratings to form a fan of diffracted beams. The fan in a prism based on a calcium fluoride (fluorite) crystal with color centers contained six out-of-plane beams radiating from a region with a hard-to-localize center. This fact hindered calibration of the measure and its application in the testing device. The use of photothermo-refractive glass as a material for preparing a sample and recording a system of holograms in it makes it possible to eliminate the drawbacks of fluorite-based prism. The number of holograms rises up to 21, the fan becomes in-plane, and its center is localized in a small region, with a size of several tenths of the sample thickness (1-2 mm). The fan beams are energetically homogeneous, and each can be identified when using the fan in a testing device.
On the tidal prism-channel area relations
NASA Astrophysics Data System (ADS)
D'Alpaos, Andrea; Lanzoni, Stefano; Marani, Marco; Rinaldo, Andrea
2010-03-01
We verify the broad applicability of tidal prism cross-sectional area relationships, originally proposed to relate the total water volume entering a lagoon during a characteristic tidal cycle (the tidal prism) to the size of its inlet, to arbitrary sheltered cross sections within a tidal network. We suggest, with reasonable approximation defining a statistical tendency rather than a pointwise equivalence, that the regime of tidal channels may be anywhere related to local landscape-forming prisms embedded in a characteristic spring tide oscillation. The importance of the proposed extension stems from its potential for quantitative predictions of the long-term morphological evolution of whole tidal landforms, in response to forcings affecting tidal prisms. This is the case, in particular, for alterations of relative mean sea levels possibly driven by climate change. Various 1-D and 2-D morphodynamic and hydrodynamic models are employed to evaluate peak flow rates, bottom shear stresses, and the ensuing local tidal prisms. One-dimensional morphodynamic models describing both the longitudinal and cross-sectional evolution of tidal channels are used to verify the validity of the relationship for sheltered sections. Relevant hydrodynamic features determined through accurate 2-D numerical models are compared with those obtained through time-invariant equivalents, defining a mean watershed by an energy landscape from averaged free surface gradients. Empirical evidence gathered within the lagoon of Venice (Italy) supports the proposed extension. We conclude that the geomorphic law relating tidal prisms to channel cross-sectional areas anywhere within a tidal landscape is a valuable tool for studies on long-term tidal geomorphology.
Design of a high-numerical-aperture digital micromirror device camera with high dynamic range.
Qiao, Yang; Xu, Xiping; Liu, Tao; Pan, Yue
2015-01-01
A high-NA imaging system with high dynamic range is presented based on a digital micromirror device (DMD). The DMD camera consists of an objective imaging system and a relay imaging system, connected by a DMD chip. With the introduction of a total internal reflection prism system, the objective imaging system is designed with a working F/# of 1.97, breaking through the F/2.45 limitation of conventional DMD projection lenses. As for the relay imaging system, an off-axis design that could correct off-axis aberrations of the tilt relay imaging system is developed. This structure has the advantage of increasing the NA of the imaging system while maintaining a compact size. Investigation revealed that the dynamic range of a DMD camera could be greatly increased, by 2.41 times. We built one prototype DMD camera with a working F/# of 1.23, and the field experiments proved the validity and reliability our work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Gao, Yuqian; Gaffrey, Matthew J.
2014-12-17
Mass spectrometry-based targeted quantification is a promising technology for site-specific quantification of posttranslational modifications (PTMs). However, a major constraint of most targeted MS approaches is the limited sensitivity for quantifying low-abundance PTMs, requiring the use of affinity reagents to enrich specific PTMs. Herein, we demonstrate the direct site-specific quantification of ERK phosphorylation isoforms (pT, pY, pTpY) and their relative stoichiometries using a highly sensitive targeted MS approach termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM). PRISM provides effective enrichment of target peptides within a given fraction from complex biological matrix with minimal sample losses, followed by selected reactionmore » monitoring (SRM) quantification. The PRISM-SRM approach enabled direct quantification of ERK phosphorylation in human mammary epithelial cells (HMEC) from as little as 25 µg tryptic peptides from whole cell lysates. Compared to immobilized metal-ion affinity chromatography, PRISM provided >10-fold improvement in signal intensities, presumably due to the better peptide recovery of PRISM for handling small size samples. This approach was applied to quantify ERK phosphorylation dynamics in HMEC treated by different doses of EGF at both the peak activation (10 min) and steady state (2 h). At 10 min, the maximal ERK activation was observed with 0.3 ng/mL dose, whereas the maximal steady state level of ERK activation at 2 h was at 3 ng/ml dose, corresponding to 1200 and 9000 occupied receptors, respectively. At 10 min, the maximally activated pTpY isoform represented ~40% of total ERK, falling to less than 10% at 2 h. The time course and dose-response profiles of individual phosphorylated ERK isoforms indicated that singly phosphorylated pT-ERK never increases significantly, while the increase of pY-ERK paralleled that of pTpY-ERK. This data supports for a processive, rather than distributed, model of ERK phosphorylation. The PRISM-SRM quantification of protein phosphorylation illustrates the potential for simultaneous quantification of multiple PTMs.« less
Rosa, J. C.; De Oliveira, P. S.; Garratt, R.; Beltramini, L.; Resing, K.; Roque-Barreira, M. C.; Greene, L. J.
1999-01-01
The complete amino acid sequence of the lectin KM+ from Artocarpus integrifolia (jackfruit), which contains 149 residues/mol, is reported and compared to those of other members of the Moraceae family, particularly that of jacalin, also from jackfruit, with which it shares 52% sequence identity. KM+ presents an acetyl-blocked N-terminus and is not posttranslationally modified by proteolytic cleavage as is the case for jacalin. Rather, it possesses a short, glycine-rich linker that unites the regions homologous to the alpha- and beta-chains of jacalin. The results of homology modeling implicate the linker sequence in sterically impeding rotation of the side chain of Asp141 within the binding site pocket. As a consequence, the aspartic acid is locked into a conformation adequate only for the recognition of equatorial hydroxyl groups on the C4 epimeric center (alpha-D-mannose, alpha-D-glucose, and their derivatives). In contrast, the internal cleavage of the jacalin chain permits free rotation of the homologous aspartic acid, rendering it capable of accepting hydrogen bonds from both possible hydroxyl configurations on C4. We suggest that, together with direct recognition of epimeric hydroxyls and the steric exclusion of disfavored ligands, conformational restriction of the lectin should be considered to be a new mechanism by which selectivity may be built into carbohydrate binding sites. Jacalin and KM+ adopt the beta-prism fold already observed in two unrelated protein families. Despite presenting little or no sequence similarity, an analysis of the beta-prism reveals a canonical feature repeatedly present in all such structures, which is based on six largely hydrophobic residues within a beta-hairpin containing two classic-type beta-bulges. We suggest the term beta-prism motif to describe this feature. PMID:10210179
Unstable Resonator Retrofitted Handheld Laser Designator
1978-06-01
retrofitted with a negative-branch unstable resona- tor laser and hybrid pump cavity in place of the conventional plane-mirror/ porro prism resonator and...directed by prism B to an expanding telescope, shared with the viewing system of the designator. The actual, unfolded resonator length is approxi...was performed based on using a plane- parallel cavity consisting of a 47% reflectivity output coupler, porro - prism reflector, and the same LiNb03
Mechanical modulation method for ultrasensitive phase measurements in photonics biosensing.
Patskovsky, S; Maisonneuve, M; Meunier, M; Kabashin, A V
2008-12-22
A novel polarimetry methodology for phase-sensitive measurements in single reflection geometry is proposed for applications in optical transduction-based biological sensing. The methodology uses altering step-like chopper-based mechanical phase modulation for orthogonal s- and p- polarizations of light reflected from the sensing interface and the extraction of phase information at different harmonics of the modulation. We show that even under a relatively simple experimental arrangement, the methodology provides the resolution of phase measurements as low as 0.007 deg. We also examine the proposed approach using Total Internal Reflection (TIR) and Surface Plasmon Resonance (SPR) geometries. For TIR geometry, the response appears to be strongly dependent on the prism material with the best values for high refractive index Si. The detection limit for Si-based TIR is estimated as 10(-5) in terms Refractive Index Units (RIU) change. SPR geometry offers much stronger phase response due to a much sharper phase characteristics. With the detection limit of 3.2*10(-7) RIU, the proposed methodology provides one of best sensitivities for phase-sensitive SPR devices. Advantages of the proposed method include high sensitivity, simplicity of experimental setup and noise immunity as a result of a high stability modulation.
Clark, Robert A.
2015-01-01
Vertical fusional vergence (VFV) normally compensates for slight vertical heterophorias. We employed magnetic resonance imaging to clarify extraocular muscle contributions to VFV induced by monocular two-prism diopter (1.15°) base-up prism in 14 normal adults. Fusion during prism viewing requires monocular infraduction. Scans were repeated without prism, and with prism shifted contralaterally. Contractility indicated by morphometric indexes was separately analyzed in medial and lateral vertical rectus and superior oblique (SO) putative compartments, and superior and inferior horizontal rectus extraocular muscle putative compartments, but in the whole inferior oblique (IO). Images confirmed appropriate VFV that was implemented by the inferior rectus (IR) medial compartment contracting ipsilateral and relaxing contralateral to prism. There was no significant contractility in the IR lateral compartment. The superior but not inferior lateral rectus (LR) compartment contracted significantly in the prism viewing eye, but not contralateral to prism. The IO contracted ipsilateral but not contralateral to the prism. In the infraducting eye, the SO medial compartment relaxed significantly, while the lateral compartment was unchanged; contralateral to prism, the SO lateral compartment contracted, while the medial compartment was unchanged. There was no contractility in the superior or medial rectus muscles in either eye. There was no globe retraction. We conclude that the vertical component of VFV is primarily implemented by IR medial compartment contraction. Since appropriate vertical rotation is not directly implemented, or is opposed, by associated differential LR and SO compartmental activity, and IO contraction, these actions probably implement a torsional component of VFV. PMID:25589593
Optimization of SPR signals: Monitoring the physical structures and refractive indices of prisms
NASA Astrophysics Data System (ADS)
Maisarah Mukhtar, Wan; Halim, Razman Mohd; Hassan, Hazirah
2017-11-01
Surface plasmon resonance (SPR) can only be achieved if sufficient energy is provided at the boundary between metal and dielectric. An employment of prism as a light coupler by using Kretschmann configuration is one of the alternative for the production of adequate energy to be generated as surface plasmon polaritons (SPP). This work is carried out to investigate the effect of physical structure of the prism and its refractive index to the excitation of SPPs. A 50nm gold thin metal film with dielectric constant of ɛ=-12.45i+1.3 was deposited on the hypotenuse surface of the prisms. The physical structures of the prisms were varied such as triangular, conical, hemispherical and half cylindrical. These prisms were classified into two types of refractive indices (RI), namely n=1.51(type BK7) and n=1.77(type SF11). Based on SPR curve analyses, we discovered that strong SPR signals which consist of 82.98% photons were excited as SPPs can be obtained by using type-BK7 prism with physical structures of hemispherical or half cylindrical. From the view of selectivity ability as sensors, the usage of type-SF11 prisms (half cylindrical and hemispherical) able to enhance this impressive feature in which sharp SPR curves with small FWHM values were obtained. In conclusion, apart from properties of thin film materials, the physical structure of prisms and their RI values play crucial roles to obtain optimum SPR signal. High sensitivity SPR sensor can be established with the appointment of type-BK7 prisms (hemispherical or half cylindrical shape) as light couplers.
Maier, Felix M; Schaeffel, Frank
2013-07-24
To find out whether adaptation to a vertical prism involves more than fusional vertical eye movements. Adaptation to a vertical base-up 3 prism diopter prism was measured in a custom-programmed Maddox test in nine visually normal emmetropic subjects (mean age 27.0 ± 2.8 years). Vertical eye movements were binocularly measured in six of the subjects with a custom-programmed binocular video eye tracker. In the Maddox test, some subjects adjusted the perceived height as expected from the power of the prism while others appeared to ignore the prism. After 15 minutes of adaptation, the interocular difference in perceived height was reduced by on average 51% (from 0.86°-0.44°). The larger the initially perceived difference in height in a subject, the larger the amplitude of adaptation was. Eye tracking showed that the prism generated divergent vertical eye movements of 1.2° on average, which was less than expected from its power. Differences in eye elevation were maintained as long as the prism was in place. Small angles of lateral head tilt generated large interocular differences in eye elevation, much larger than the effects introduced by the prism. Vertical differences in retinal image height were compensated by vertical fusional eye movements but some subjects responded poorly to a vertical prism in both experiments; fusional eye movements were generally too small to realign both foveae with the fixation target; and the prism adaptation in the Maddox test was fully explained by the changes in vertical eye position, suggesting that no further adaptational mechanism may be involved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sokolov, V I; Marusin, N V; Molchanova, S I
2014-11-30
The problem of reflection of a TE-polarised Gaussian light beam from a layered structure under conditions of resonance excitation of waveguide modes using a total internal reflection prism is considered. Using the spectral approach we have derived the analytic expressions for the mode propagation lengths, widths and depths of m-lines (sharp and narrow dips in the angular dependence of the specular reflection coefficient), depending on the structure parameters. It is shown that in the case of weak coupling, when the propagation lengths l{sub m} of the waveguide modes are mainly determined by the extinction coefficient in the film, the depthmore » of m-lines grows with the mode number m. In the case of strong coupling, when l{sub m} is determined mainly by the radiation of modes into the prism, the depth of m-lines decreases with increasing m. The change in the TE-polarised Gaussian beam shape after its reflection from the layered structure is studied, which is determined by the energy transfer from the incident beam into waveguide modes that propagate along the structure by the distance l{sub m}, are radiated in the direction of specular reflection and interfere with a part of the beam reflected from the working face of the prism. It is shown that this interference can lead to the field intensity oscillations near m-lines. The analysis of different methods for determining the parameters of thin-film structures is presented, including the measurement of mode angles θ{sub m} and the reflected beam shape. The methods are based on simultaneous excitation of a few waveguide modes in the film with a strongly focused monochromatic Gaussian beam, the waist width of which is much smaller than the propagation length of the modes. As an example of using these methods, the refractive index and the thickness of silicon monoxide film on silica substrate at the wavelength 633 nm are determined. (fibre and integrated-optical structures)« less
Prism-based single-camera system for stereo display
NASA Astrophysics Data System (ADS)
Zhao, Yue; Cui, Xiaoyu; Wang, Zhiguo; Chen, Hongsheng; Fan, Heyu; Wu, Teresa
2016-06-01
This paper combines the prism and single camera and puts forward a method of stereo imaging with low cost. First of all, according to the principle of geometrical optics, we can deduce the relationship between the prism single-camera system and dual-camera system, and according to the principle of binocular vision we can deduce the relationship between binoculars and dual camera. Thus we can establish the relationship between the prism single-camera system and binoculars and get the positional relation of prism, camera, and object with the best effect of stereo display. Finally, using the active shutter stereo glasses of NVIDIA Company, we can realize the three-dimensional (3-D) display of the object. The experimental results show that the proposed approach can make use of the prism single-camera system to simulate the various observation manners of eyes. The stereo imaging system, which is designed by the method proposed by this paper, can restore the 3-D shape of the object being photographed factually.
Train integrity detection risk analysis based on PRISM
NASA Astrophysics Data System (ADS)
Wen, Yuan
2018-04-01
GNSS based Train Integrity Monitoring System (TIMS) is an effective and low-cost detection scheme for train integrity detection. However, as an external auxiliary system of CTCS, GNSS may be influenced by external environments, such as uncertainty of wireless communication channels, which may lead to the failure of communication and positioning. In order to guarantee the reliability and safety of train operation, a risk analysis method of train integrity detection based on PRISM is proposed in this article. First, we analyze the risk factors (in GNSS communication process and the on-board communication process) and model them. Then, we evaluate the performance of the model in PRISM based on the field data. Finally, we discuss how these risk factors influence the train integrity detection process.
Development and calibration of an accurate 6-degree-of-freedom measurement system with total station
NASA Astrophysics Data System (ADS)
Gao, Yang; Lin, Jiarui; Yang, Linghui; Zhu, Jigui
2016-12-01
To meet the demand of high-accuracy, long-range and portable use in large-scale metrology for pose measurement, this paper develops a 6-degree-of-freedom (6-DOF) measurement system based on total station by utilizing its advantages of long range and relative high accuracy. The cooperative target sensor, which is mainly composed of a pinhole prism, an industrial lens, a camera and a biaxial inclinometer, is designed to be portable in use. Subsequently, a precise mathematical model is proposed from the input variables observed by total station, imaging system and inclinometer to the output six pose variables. The model must be calibrated in two levels: the intrinsic parameters of imaging system, and the rotation matrix between coordinate systems of the camera and the inclinometer. Then corresponding approaches are presented. For the first level, we introduce a precise two-axis rotary table as a calibration reference. And for the second level, we propose a calibration method by varying the pose of a rigid body with the target sensor and a reference prism on it. Finally, through simulations and various experiments, the feasibilities of the measurement model and calibration methods are validated, and the measurement accuracy of the system is evaluated.
NASA Astrophysics Data System (ADS)
Vlaeva, I.; Petkov, K.; Tasseva, J.; Todorov, R.; Yovcheva, T.; Sainov, S.
2010-12-01
We report the results of electric field influence on holographic recording in very thin chalcogenide glass films. The total internal reflection prism recording technique (Stetson's scheme) is applied for holographic recording. The main advantage of this scheme is the possibility of holographic recording in micro- and nanometer thick photosensitive materials. In the present work, 30 nm, 50 nm and 1.0 µm thick films are used. In the 1.0 µm thick film two slanted gratings are simultaneously recorded. In this recording geometry only one reconstructed beam is observed. The corona charging influence on the diffraction efficiency of the recorded gratings is investigated. A negative voltage of 5 kV is applied to the corona electrode (needle) prior to the holographic recording. The observed diffraction efficiency of charged samples is always higher in comparison with uncharged samples. The reconstructed beam intensity is monitored with a red (635 nm) semiconductor laser. The possible reason is an additional refractive index modulation due to the increase in polarization, caused by the electric charging.
Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia.
Bowers, Alex R; Keeney, Karen; Peli, Eli
2014-02-01
There is a major lack of randomized controlled clinical trials evaluating the efficacy of prismatic treatments for hemianopia. Evidence for their effectiveness is mostly based on anecdotal case reports and open-label evaluations without a control condition. To evaluate the efficacy of real relative to sham peripheral prism glasses for patients with complete homonymous hemianopia. Double-masked, randomized crossover trial at 13 study sites, including the Peli laboratory at Schepens Eye Research Institute, 11 vision rehabilitation clinics in the United States, and 1 in the United Kingdom. Patients were 18 years or older with complete homonymous hemianopia for at least 3 months and without visual neglect or significant cognitive decline. Patients were allocated by minimization into 2 groups. One group received real (57-prism diopter) oblique and sham (<5-prism diopter) horizontal prisms; the other received real horizontal and sham oblique, in counterbalanced order. Each crossover period was 4 weeks. The primary outcome was the overall difference, across the 2 periods of the crossover, between the proportion of participants who wanted to continue with (said yes to) real prisms and the proportion who said yes to sham prisms. The secondary outcome was the difference in perceived mobility improvement between real and sham prisms. Of 73 patients randomized, 61 completed the crossover. A significantly higher proportion said yes to real than sham prisms (64% vs 36%; odds ratio, 5.3; 95% CI, 1.8-21.0). Participants who continued wear after 6 months reported greater improvement in mobility with real than sham prisms at crossover end (P = .002); participants who discontinued wear reported no difference. Real peripheral prism glasses were more helpful for obstacle avoidance when walking than sham glasses, with no differences between the horizontal and oblique designs. Peripheral prism glasses provide a simple and inexpensive mobility rehabilitation intervention for hemianopia. clinicaltrials.gov Identifier: NCT00494676.
Prism. Volume 1, Number 1, December 2009
2009-12-01
a generation or more. This is a consequence of paradoxical tendencies within the international system. On the one hand, globalization, the... consequence is that an agency has two missions for every one it is assigned. In addition to achieving a successful outcome, there is an internal mission...for International Development, established the CCO as an innovative interagency partnership. Subscriptions for individuals: http://bookstore.gpo.gov
Robust sensor for turbidity measurement from light scattering and absorbing liquids.
Kontturi, Ville; Turunen, Petri; Uozumi, Jun; Peiponen, Kai-Erik
2009-12-01
Internationally standardized turbidity measurements for probing solid particles in liquid are problematic in the case of simultaneous light scattering and absorption. A method and a sensor to determine the turbidity in the presence of light absorption are presented. The developed sensor makes use of the total internal reflection of a laser beam at the liquid-prism interface, and the turbidity is assessed using the concept of laser speckle pattern. Using average filtering in speckle data analyzing the observed dynamic speckle pattern, which is due to light scattering from particles and the static speckle due to stray light of the sensor, can be separated from each other. Good correlation between the standard deviation of dynamic speckle and turbidity value for nonabsorbing and for absorbing liquids was observed. The sensor is suggested, for instance, for the measurement of ill-behaved as well as small-volume turbid liquids in both medicine and process industry.
Forward and inverse solutions for Risley prism based on the Denavit-Hartenberg methodology
NASA Astrophysics Data System (ADS)
Beltran-Gonzalez, A.; Garcia-Torales, G.; Strojnik, M.; Flores, J. L.; Garcia-Luna, J. L.
2017-08-01
In this work forward and inverse solutions for two-element Risley prism for pointing and scanning beam systems are developed. A more efficient and faster algorithm is proposed to make an analogy of the Risley prism system compared with a robotic system with two degrees of freedom. This system of equations controls each Risley prism individually as a planar manipulator arm of two links. In order to evaluate the algorithm we implement it in a pointing system. We perform popular routines such as the linear, spiral and loops traces. Using forward and inverse solutions for two-element Risley prism it is also possible to point at coordinates specified by the user, provided they are within the pointer area of work area. Experimental results are showed as a validation of our proposal.
Propagation of rotational Risley-prism-array-based Gaussian beams in turbulent atmosphere
NASA Astrophysics Data System (ADS)
Chen, Feng; Ma, Haotong; Dong, Li; Ren, Ge; Qi, Bo; Tan, Yufeng
2018-03-01
Limited by the size and weight of prism and optical assembling, Rotational Risley-prism-array system is a simple but effective way to realize high power and superior beam quality of deflecting laser output. In this paper, the propagation of the rotational Risley-prism-array-based Gaussian beam array in atmospheric turbulence is studied in detail. An analytical expression for the average intensity distribution at the receiving plane is derived based on nonparaxial ray tracing method and extended Huygens-Fresnel principle. Power in the diffraction-limited bucket is chosen to evaluate beam quality. The effect of deviation angle, propagation distance and intensity of turbulence on beam quality is studied in detail by quantitative simulation. It reveals that with the propagation distance increasing, the intensity distribution gradually evolves from multiple-petal-like shape into the pattern that contains one main-lobe in the center with multiple side-lobes in weak turbulence. The beam quality of rotational Risley-prism-array-based Gaussian beam array with lower deviation angle is better than its counterpart with higher deviation angle when propagating in weak and medium turbulent (i.e. Cn2 < 10-13m-2/3), the beam quality of higher deviation angle arrays degrades faster as the intensity of turbulence gets stronger. In the case of propagating in strong turbulence, the long propagation distance (i.e. z > 10km ) and deviation angle have no influence on beam quality.
SU-G-IeP1-13: Sub-Nyquist Dynamic MRI Via Prior Rank, Intensity and Sparsity Model (PRISM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, B; Gao, H
Purpose: Accelerated dynamic MRI is important for MRI guided radiotherapy. Inspired by compressive sensing (CS), sub-Nyquist dynamic MRI has been an active research area, i.e., sparse sampling in k-t space for accelerated dynamic MRI. This work is to investigate sub-Nyquist dynamic MRI via a previously developed CS model, namely Prior Rank, Intensity and Sparsity Model (PRISM). Methods: The proposed method utilizes PRISM with rank minimization and incoherent sampling patterns for sub-Nyquist reconstruction. In PRISM, the low-rank background image, which is automatically calculated by rank minimization, is excluded from the L1 minimization step of the CS reconstruction to further sparsify themore » residual image, thus allowing for higher acceleration rates. Furthermore, the sampling pattern in k-t space is made more incoherent by sampling a different set of k-space points at different temporal frames. Results: Reconstruction results from L1-sparsity method and PRISM method with 30% undersampled data and 15% undersampled data are compared to demonstrate the power of PRISM for dynamic MRI. Conclusion: A sub- Nyquist MRI reconstruction method based on PRISM is developed with improved image quality from the L1-sparsity method.« less
High frequent total station measurements for the monitoring of bridge vibrations
NASA Astrophysics Data System (ADS)
Lienhart, Werner; Ehrhart, Matthias; Grick, Magdalena
2017-03-01
Robotic total stations (RTS) are frequently used for the measurement of temperature induced bridge deformations or during load testing of bridges. In experimental setups, total stations have also been used for the measurement of dynamic bridge deformations. However, with standard configurations the measurement rate is not constant and on average an update rate of 7-10Hz can be achieved. This is not sufficient for the vibration monitoring of bridges considering their natural frequencies which are also in the same range. In this paper, we present different approaches to overcome these problems. In the first two approaches we demonstrate how the measurement rate to prisms can be increased to 20Hz to determine vertical deformations of bridges. Critical aspects like the measurement resolution of the automated target tracking and the correct sequence of steering commands are discussed. In another approach we demonstrate how vertical bridge vibrations can be measured using an image assisted total station (IATS) and corresponding processing techniques. The advantage of image-based methods is that structural features of a bridge like bolts can be used as targets. Therefore, no expensive prisms have to be mounted and access to the bridge is not required. All approaches are verified by laboratory investigations and their suitability is proven in a field experiment on a 74m long footbridge. In this field experiment the natural frequencies derived from the total station measurements are compared to the results of accelerometer measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pentz, David L.; Stoll, Ralph H.; Greeves, John T.
2012-07-01
The PRISM (Prioritization Risk Integration Simulation Model), a computer model was developed to support the Department of Energy's Office of Environmental Management (DOE-EM) in its mission to clean up the environmental legacy from the Nation's nuclear weapons materials production complex. PRISM provides a comprehensive, fully integrated planning tool that can tie together DOE-EM's projects. It is designed to help DOE managers develop sound, risk-informed business practices and defend program decisions. It provides a better ability to understand and manage programmatic risks. The underlying concept for PRISM is that DOE-EM 'owns' a portfolio of environmental legacy obligations (ELOs), and that itsmore » mission is to transform the ELOs from their current conditions to acceptable conditions, in the most effective way possible. There are many types of ELOs - - contaminated soils and groundwater plumes, disused facilities awaiting D and D, and various types of wastes waiting for processing or disposal. For a given suite of planned activities, PRISM simulates the outcomes as they play out over time, allowing for all key identified uncertainties and risk factors. Each contaminated building, land area and waste stream is tracked from cradle to grave, and all of the linkages affecting different waste streams are captured. The progression of the activities is fully dynamic, reflecting DOE-EM's prioritization approaches, precedence requirements, available funding, and the consequences of risks and uncertainties. The top level of PRISM is the end-user interface that allows rapid evaluation of alternative scenarios and viewing the results in a variety of useful ways. PRISM is a fully probabilistic model, allowing the user to specify uncertainties in input data (such as the magnitude of an existing groundwater plume, or the total cost to complete a planned activity) as well as specific risk events that might occur. PRISM is based on the GoldSim software that is widely used for risk and performance assessment calculations. PRISM can be run in a deterministic mode, which quickly provides an estimate of the most likely results of a given plan. Alternatively, the model can be run probabilistically in a Monte Carlo mode, exploring the risks and uncertainties in the system and producing probability distributions for the different performance measures. The PRISM model demonstrates how EM can evaluate a portfolio of ELOs, and transform the ELOs from their current conditions to acceptable conditions, utilizing different strategic approaches. There are many types of ELOs - contaminated soils and groundwater plumes, disused facilities awaiting D and D, and various types of wastes waiting for processing or disposal. This scope of work for the PRISM process and the development of a dynamic simulation model are a logical extension of the GoldSim simulation software used by the OCRWM to assess the long-term performance for the Yucca Mountain Project and by NNSA to assess project risk at its sites. Systems integration modeling will promote better understanding of all project risks, technical and nontechnical, and more defensible decision-making for complex projects with significant uncertainties. It can provide effective visual communication and rapid adaptation during interactions with stakeholders (Administration, Congress, State, Local, and NGO). It will also allow rapid assessment of alternative management approaches. (authors)« less
Numerical simulation of blast wave propagation in vicinity of standalone prism on flat plate
NASA Astrophysics Data System (ADS)
Valger, Svetlana; Fedorova, Natalya; Fedorov, Alexander
2018-03-01
In the paper, numerical simulation of shock wave propagation in the vicinity of a standalone prism and a prism with a cavity in front of it was carried out. The modeling was based on the solution of 3D Euler equations and Fluent software was used as a main computational tool. The algorithm for local dynamic mesh adaptation to high gradients of pressure was applied. The initial stage of the explosion of condensed explosive was described with the help of "Compressed balloon method". The research allowed describing the characteristic stages of the blast in a semi-closed space, the structure of secondary shock waves and their interaction with obstacles. The numerical approach in Fluent based on combining inviscid gas dynamics methods and "Compressed balloon method" was compared with the method which had been used by the authors earlier with the help of AUTODYN and which is based on the use of the hydrodynamic model of a material to describe state of detonation products. For the problem of shock wave propagation in the vicinity of standalone prism the comparison of the simulation results obtained using both the methods with the experimental data was performed on the dependence of static pressure and effective momentum on time for the characteristic points located on prism walls.
Post-licensure rapid immunization safety monitoring program (PRISM) data characterization.
Baker, Meghan A; Nguyen, Michael; Cole, David V; Lee, Grace M; Lieu, Tracy A
2013-12-30
The Post-Licensure Rapid Immunization Safety Monitoring (PRISM) program is the immunization safety monitoring component of FDA's Mini-Sentinel project, a program to actively monitor the safety of medical products using electronic health information. FDA sought to assess the surveillance capabilities of this large claims-based distributed database for vaccine safety surveillance by characterizing the underlying data. We characterized data available on vaccine exposures in PRISM, estimated how much additional data was gained by matching with select state and local immunization registries, and compared vaccination coverage estimates based on PRISM data with other available data sources. We generated rates of computerized codes representing potential health outcomes relevant to vaccine safety monitoring. Standardized algorithms including ICD-9 codes, number of codes required, exclusion criteria and location of the encounter were used to obtain the background rates. The majority of the vaccines routinely administered to infants, children, adolescents and adults were well captured by claims data. Immunization registry data in up to seven states comprised between 5% and 9% of data for all vaccine categories with the exception of 10% for hepatitis B and 3% and 4% for rotavirus and zoster respectively. Vaccination coverage estimates based on PRISM's computerized data were similar to but lower than coverage estimates from the National Immunization Survey and Healthcare Effectiveness Data and Information Set. For the 25 health outcomes of interest studied, the rates of potential outcomes based on ICD-9 codes were generally higher than rates described in the literature, which are typically clinically confirmed cases. PRISM program's data on vaccine exposures and health outcomes appear complete enough to support robust safety monitoring. Copyright © 2013 Elsevier Ltd. All rights reserved.
Nomura, Kouji; Nakaji-Hirabayashi, Tadashi; Gemmei-Ide, Makoto; Kitano, Hiromi; Noguchi, Hidenori; Uosaki, Kohei
2014-09-01
Surfaces of both a cover glass and the flat plane of a semi-cylindrical quartz prism were modified with a mixture of positively and negatively charged silane coupling reagents (3-aminopropyltriethoxysilane (APTES) and 3-(trihydroxysilyl)propylmethylphosphonate (THPMP), respectively). The glass surface modified with a self-assembled monolayer (SAM) prepared at a mixing ratio of APTES:THPMP=4:6 was electrically almost neutral and was resistant to non-specific adsorption of proteins, whereas fibroblasts gradually adhered to an amphoteric (mixed) SAM surface probably due to its stiffness, though the number of adhered cells was relatively small. Sum frequency generation (SFG) spectra indicated that total intensity of the OH stretching region (3000-3600cm(-1)) for the amphoteric SAM-modified quartz immersed in liquid water was smaller than those for the positively and negatively charged SAM-modified quartz prisms and a bare quartz prism in contact with liquid water. These results suggested that water molecules at the interface of water and an amphoteric SAM-modified quartz prism are not strongly oriented in comparison with those at the interface of a lopsidedly charged SAM-modified quartz prism and bare quartz. The importance of charge neutralization for the anti-biofouling properties of solid materials was strongly suggested. Copyright © 2014 Elsevier B.V. All rights reserved.
Oh, Se-Il; Kim, Jin-Kyung; Park, So-Yeon
2015-12-01
[Purpose] This study aimed to examine the effects of visual field with prism glasses, and intensive upper limb functional training on reduction of hemineglect and improvement in upper limb function and activities of daily living in three stroke patients with hemineglect. [Subjects] This study included three stroke patients hospitalized in a sanatorium. [Methods] Intervention treatment involving prism glass use for 12 hours and 30 minutes and paretic side upper limb training was conducted 5 days a week for 15 weeks. Three upper limb training tasks (hitting a balloon, passing through a ring, and reading a newspaper) were performed for 10 minutes each session, for a total of 30 minutes. Line by Section, Motor-Free Visual Perception Test-3 (MVPT-3), Manual Function Test (MFT), Box & Block Test (BBT), and Assessment of Motor and Process Skills (AMPS) were conducted before and after intervention. [Results] Subjects' hemineglect decreased and upper limb function on the paretic side improved after intervention, which enhanced activities of daily living. [Conclusion] Prism glass use and paretic upper limb functional training effectively ameliorated stroke patients' hemineglect and improved upper limb function. Future research should focus on prism glasses that provide a wide visual field for use in patients with different conditions.
Hotchkiss, David R; Aqil, Anwer; Lippeveld, Theo; Mukooyo, Edward
2010-07-03
Sound policy, resource allocation and day-to-day management decisions in the health sector require timely information from routine health information systems (RHIS). In most low- and middle-income countries, the RHIS is viewed as being inadequate in providing quality data and continuous information that can be used to help improve health system performance. In addition, there is limited evidence on the effectiveness of RHIS strengthening interventions in improving data quality and use. The purpose of this study is to evaluate the usefulness of the newly developed Performance of Routine Information System Management (PRISM) framework, which consists of a conceptual framework and associated data collection and analysis tools to assess, design, strengthen and evaluate RHIS. The specific objectives of the study are: a) to assess the reliability and validity of the PRISM instruments and b) to assess the validity of the PRISM conceptual framework. Facility- and worker-level data were collected from 110 health care facilities in twelve districts in Uganda in 2004 and 2007 using records reviews, structured interviews and self-administered questionnaires. The analysis procedures include Cronbach's alpha to assess internal consistency of selected instruments, test-retest analysis to assess the reliability and sensitivity of the instruments, and bivariate and multivariate statistical techniques to assess validity of the PRISM instruments and conceptual framework. Cronbach's alpha analysis suggests high reliability (0.7 or greater) for the indices measuring a promotion of a culture of information, RHIS tasks self-efficacy and motivation. The study results also suggest that a promotion of a culture of information influences RHIS tasks self-efficacy, RHIS tasks competence and motivation, and that self-efficacy and the presence of RHIS staff have a direct influence on the use of RHIS information, a key aspect of RHIS performance. The study results provide some empirical support for the reliability and validity of the PRISM instruments and the validity of the PRISM conceptual framework, suggesting that the PRISM approach can be effectively used by RHIS policy makers and practitioners to assess the RHIS and evaluate RHIS strengthening interventions. However, additional studies with larger sample sizes are needed to further investigate the value of the PRISM instruments in exploring the linkages between RHIS data quality and use, and health systems performance.
Affective three-dimensional brain-computer interface created using a prism array-based display
NASA Astrophysics Data System (ADS)
Mun, Sungchul; Park, Min-Chul
2014-12-01
To avoid the vergence-accommodation mismatch and provide a strong sense of presence to users, we applied a prism array-based display when presenting three-dimensional (3-D) objects. Emotional pictures were used as visual stimuli to increase the signal-to-noise ratios of steady-state visually evoked potentials (SSVEPs) because involuntarily motivated selective attention by affective mechanisms can enhance SSVEP amplitudes, thus producing increased interaction efficiency. Ten male and nine female participants voluntarily participated in our experiments. Participants were asked to control objects under three viewing conditions: two-dimension (2-D), stereoscopic 3-D, and prism. The participants performed each condition in a counter-balanced order. One-way repeated measures analysis of variance showed significant increases in the positive predictive values in the prism condition compared to the 2-D and 3-D conditions. Participants' subjective ratings of realness and engagement were also significantly greater in the prism condition than in the 2-D and 3-D conditions, while the ratings for visual fatigue were significantly reduced in the prism condition than in the 3-D condition. The proposed methods are expected to enhance the sense of reality in 3-D space without causing critical visual fatigue. In addition, people who are especially susceptible to stereoscopic 3-D may be able to use the affective brain-computer interface.
Simulator scene display evaluation device
NASA Technical Reports Server (NTRS)
Haines, R. F. (Inventor)
1986-01-01
An apparatus for aligning and calibrating scene displays in an aircraft simulator has a base on which all of the instruments for the aligning and calibrating are mounted. Laser directs beam at double right prism which is attached to pivoting support on base. The pivot point of the prism is located at the design eye point (DEP) of simulator during the aligning and calibrating. The objective lens in the base is movable on a track to follow the laser beam at different angles within the field of vision at the DEP. An eyepiece and a precision diopter are movable into a position behind the prism during the scene evaluation. A photometer or illuminometer is pivotable about the pivot into and out of position behind the eyepiece.
Forward modeling of the Earth's lithospheric field using spherical prisms
NASA Astrophysics Data System (ADS)
Baykiev, Eldar; Ebbing, Jörg; Brönner, Marco; Fabian, Karl
2014-05-01
The ESA satellite mission Swarm consists of three satellites that measure the magnetic field of the Earth at average flight heights of about 450 km and 530 km above surface. Realistic forward modeling of the expected data is an indispensible first step for both, evaluation and inversion of the real data set. This forward modeling requires a precise definition of the spherical geometry of the magnetic sources. At satellite height only long wavelengths of the magnetic anomalies are reliably measured. Because these are very sensitive to the modeling error in case of a local flat Earth approximation, conventional magnetic modeling tools cannot be reliably used. For an improved modeling approach, we start from the existing gravity modeling code "tesseroids" (http://leouieda.github.io/tesseroids/), which calculates gravity gradient tensor components for any collection of spherical prisms (tesseroids). By Poisson's relation the magnetic field is mathematically equivalent to the gradient of a gravity field. It is therefore directly possible to apply "tesseroids" for magnetic field modeling. To this end, the Earth crust is covered by spherical prisms, each with its own prescribed magnetic susceptibility and remanent magnetization. Induced magnetizations are then derived from the products of the local geomagnetic fields for the chosen main field model (such as the International Geomagnetic Reference Field), and the corresponding tesseroid susceptibilities. Remanent magnetization vectors are directly set. This method inherits the functionality of the original "tesseroids" code and performs parallel computation of the magnetic field vector components on any given grid. Initial global calculations for a simplified geometry and piecewise constant magnetization for each tesseroid show that the method is self-consistent and reproduces theoretically expected results. Synthetic induced crustal magnetic fields and total field anomalies of the CRUST1.0 model converted to magnetic tesseroids reproduce the results of previous forward modelling methods (e.g. using point dipoles as magnetic sources), while reducing error terms. Moreover the spherical-prism method can easily be linked to other geophysical forward or inverse modelling tools. Sensitivity analysis over Fennoscandia will be used to estimate if and how induced and remanent magnetization can be distinguished in data from the Swarm satellite mission.
Prism adaptation and generalization during visually guided locomotor tasks.
Alexander, M Scott; Flodin, Brent W G; Marigold, Daniel S
2011-08-01
The ability of individuals to adapt locomotion to constraints associated with the complex environments normally encountered in everyday life is paramount for survival. Here, we tested the ability of 24 healthy young adults to adapt to a rightward prism shift (∼11.3°) while either walking and stepping to targets (i.e., precision stepping task) or stepping over an obstacle (i.e., obstacle avoidance task). We subsequently tested for generalization to the other locomotor task. In the precision stepping task, we determined the lateral end-point error of foot placement from the targets. In the obstacle avoidance task, we determined toe clearance and lateral foot placement distance from the obstacle before and after stepping over the obstacle. We found large, rightward deviations in foot placement on initial exposure to prisms in both tasks. The majority of measures demonstrated adaptation over repeated trials, and adaptation rates were dependent mainly on the task. On removal of the prisms, we observed negative aftereffects for measures of both tasks. Additionally, we found a unilateral symmetric generalization pattern in that the left, but not the right, lower limb indicated generalization across the 2 locomotor tasks. These results indicate that the nervous system is capable of rapidly adapting to a visuomotor mismatch during visually demanding locomotor tasks and that the prism-induced adaptation can, at least partially, generalize across these tasks. The results also support the notion that the nervous system utilizes an internal model for the control of visually guided locomotion.
Sanford, Ward E.; Nelms, David L.; Pope, Jason P.; Selnick, David L.
2015-01-01
Mean long-term hydrologic budget components, such as recharge and base flow, are often difficult to estimate because they can vary substantially in space and time. Mean long-term fluxes were calculated in this study for precipitation, surface runoff, infiltration, total evapotranspiration (ET), riparian ET, recharge, base flow (or groundwater discharge) and net total outflow using long-term estimates of mean ET and precipitation and the assumption that the relative change in storage over that 30-year period is small compared to the total ET or precipitation. Fluxes of these components were first estimated on a number of real-time-gaged watersheds across Virginia. Specific conductance was used to distinguish and separate surface runoff from base flow. Specific-conductance (SC) data were collected every 15 minutes at 75 real-time gages for approximately 18 months between March 2007 and August 2008. Precipitation was estimated for 1971-2000 using PRISM climate data. Precipitation and temperature from the PRISM data were used to develop a regression-based relation to estimate total ET. The proportion of watershed precipitation that becomes surface runoff was related to physiographic province and rock type in a runoff regression equation. A new approach to estimate riparian ET using seasonal SC data gave results consistent with those from other methods. Component flux estimates from the watersheds were transferred to flux estimates for counties and independent cities using the ET and runoff regression equations. Only 48 of the 75 watersheds yielded sufficient data, and data from these 48 were used in the final runoff regression equation. Final results for the study are presented as component flux estimates for all counties and independent cities in Virginia. The method has the potential to be applied in many other states in the U.S. or in other regions or countries of the world where climate and stream flow data are plentiful.
TRMM-3B43 Bias Correction over the High Elevations of the Contiguous United States
NASA Astrophysics Data System (ADS)
Hashemi, H.; Nordin, K. M.; Lakshmi, V.; Knight, R. J.
2016-12-01
Precipitation can be quantified using a rain gauge network, or a remotely sensed precipitation product. Ultimately, the choice of dataset depends on the particular application, the catchment size, climate and the time period of study. In a region with a long record and a dense rain gauge network, the elevation-modified ground-based precipitation product, PRISM, has been found to work well. However, in poorly gauged regions the use of remotely sensed precipitation products is an absolute necessity. The Tropical Rainfall Measuring Mission (TRMM) has provided valuable precipitation datasets for hydrometeorological studies over the past two decades (1998-2015). One concern regarding the usage of TRMM data is the accuracy of the precipitation estimates, when compared to those obtained using PRISM. The reason for this concern is that TRMM and PRISM do not always agree and, typically, TRMM underestimates PRISM over the mountainous regions of the United States. In this study, we develop a correction function to improve the accuracy of the TRMM monthly product (TRMM-3B43) by estimating and removing the bias in the satellite data using the ground-based precipitation product, PRISM. We observe a strong relationship between the bias and land surface elevation; TRMM-3B43 tends to underestimate the PRISM product at altitudes greater than 1500 m above mean sea level (m.amsl) in the contiguous United States. A relationship is developed between TRMM-PRISM bias and elevation. The correction function is used to adjust the TRMM monthly precipitation using PRISM and elevation data. The model is calibrated using 25% of the available time period and the remaining 75% of the time period is used for validation. The corrected TRMM-3B43 product is verified for the high elevations over the contiguous United States and two local regions in the mountainous areas of the western United States. The results show a significant improvement in the accuracy of the TRMM product in the high elevations of the contiguous United States.
PRISM Polarimetry of Massive Stars
NASA Astrophysics Data System (ADS)
Kerkstra, Brennan; Lomax, Jamie R.; Bjorkman, Karen S.; Bjorkman, Jon Eric; Skiff, Brian; Covey, Kevin R.; Wisniewski, John P.
2016-01-01
We present the early results from our long-term, multi-epoch filter polarization survey of massive stars in and around young Galactic clusters. These BVRI polarization data were obtained using the PRISM instrument mounted on the 1.8m Perkins Telescope at Lowell Observatory. We first detail the creation of our new semi-automated polarization data reduction pipeline that we developed to process these data. Next, we present our analysis of the instrumental polarization properties of the PRISM instrument, via observations of polarized and unpolarized standard stars. Finally, we present early results on the total and intrinsic polarization behavior of several isolated, previously suggested classical Be stars, and discuss these results in the context of the larger project.BK acknowledges support from a NSF/REU at the University of Oklahoma. This program was also supported by NSF-AST 11411563, 1412110, and 1412135.
Full-wave simulation of a three-dimensional metamaterial prism
Basilio, Lorena I.; Langston, William L.; Warne, Larry K.; ...
2015-01-23
In our article, a negative-index metamaterial prism based on a composite unit cell containing a split-ring resonator and a z-dipole is designed and simulated. The design approach combines simulations of a single unit cell to identify the appropriate cell design (yielding the desired negative-index behavior) together with subcell modeling (which simplifies the mesh representation of the resonator geometry and allows for a larger number of resonator cells to be handled). Furthermore, to describe the methodology used in designing a n = -1 refractive index prism, our results include the effective-medium parameters, the far-field scattered patterns, and the near-zone field distributionsmore » corresponding to a normally incident plane-wave excitation of the prism.« less
Damage identification in cement paste amended with carbon nanotubes
NASA Astrophysics Data System (ADS)
Soltangharaei, Vafa; Anay, Rafal; Assi, Lateef; Ziehl, Paul; Matta, Fabio
2018-04-01
Cement-based composites have been used as reliable materials in building and civil engineering infrastructure for many decades. Although there are several advantages, some drawbacks such as premature cracking may be problematic for sensitive applications such as those found in nuclear power plants or associated waste storage facilities. In this study, acoustic emission monitoring was employed to detect stress waves associated with damage progression during uniaxial compressive loading. Acoustic emission data resulting from loading of plain cement paste prisms and cement paste prisms amended with carbon nanotubes are compared. Unsupervised pattern recognition is employed to categorize the data. Results indicate that increased acoustic emission activity was recorded for the plain cement paste prisms when compared to prisms amended with carbon nanotubes.
Azzam, R M A; De, A
2003-03-01
A symmetric achiral trilayer structure, which consists of a high-index center layer sandwiched between two identical low-index films and embedded in a high-index prism, is designed to produce equal and opposite quarter-wave retardation in reflection and transmission and equal throughput for the p and s polarization at oblique incidence. Such a device splits a beam of incident linearly polarized light into two orthogonally circularly polarized components of equal power that travel in different directions. A visible (633-nm) design that operates at a 60 degree angle of incidence and an infrared (10.6-microm) 45 degree cube design are presented. The spectral and angular sensitivities of the device are also considered.
Esfahlani, Hussein; Karkar, Sami; Lissek, Herve; Mosig, Juan R
2016-01-07
The optical dispersive prism is a well-studied element, which allows separating white light into its constituent spectral colors, and stands in nature as water droplets. In analogy to this definition, the acoustic dispersive prism should be an acoustic device with capability of splitting a broadband acoustic wave into its constituent Fourier components. However, due to the acoustical nature of materials as well as the design and fabrication difficulties, there is neither any natural acoustic counterpart of the optical prism, nor any artificial design reported so far exhibiting an equivalent acoustic behaviour. Here, based on exotic properties of the acoustic transmission-line metamaterials and exploiting unique physical behaviour of acoustic leaky-wave radiation, we report the first acoustic dispersive prism, effective within the audible frequency range 800 Hz-1300 Hz. The dispersive nature, and consequently the frequency-dependent refractive index of the metamaterial are exploited to split the sound waves towards different and frequency-dependent directions. Meanwhile, the leaky-wave nature of the structure facilitates the sound wave radiation into the ambient medium.
NASA Astrophysics Data System (ADS)
Kaur, Gurpreet; Tomar, Monika; Gupta, Vinay
2015-11-01
ZnO thin film was deposited on gold coated glass prism by RF sputtering technique in glancing angle deposition (GLAD) configuration. The structural, morphological and optical properties of the deposited film were investigated using X-ray diffraction (XRD), Atomic Force Microscopy (AFM) and Fourier Transform Infrared (FTIR) Spectroscopy. ZnO coated Au prisms (ZnO/Au/prism) were used to excite surface plasmons in Kretschmann configuration at the Au- ZnO interface on a laboratory assembled Surface Plasmon Resonance (SPR) measurement setup. Cholesterol oxidase (ChOx) enzyme was immobilized on the ZnO/Au/prism structure by physical adsorption technique. Polydimethylsiloxane (PDMS) microchannels were fabricated over ChOx/ZnO/Au/prism system and various concentrations of cholesterol were passed over the sensor surface. The concentration of cholesterol was varied from 0.12 to 10.23 mM and the SPR reflectance curves were recorded in both static as well as dynamic modes demonstrating a high sensitivity of 0.36° mM-1.
Switching terahertz wave with grating-coupled Kretschmann configuration.
Jiu-Sheng, Li
2017-08-07
We present a terahertz wave switch utilizing Kretschmann configuration which consists of high-refractive-index prism-liquid crystal-periodically grooved metal grating. The switching mechanism of the terahertz switch is based on spoof surface plasmon polariton (SSPP) excitation in the attenuated total reflection regime by changing the liquid crystal refractive index. The results highlighted the fact that the feasibility to "tune" the attenuated total reflection terahertz wave intensity by using the external applied bias voltage. The extinction ratio of the terahertz switch reaches 31.48dB. The terahertz switch has good control ability and flexibility, and can be used in potential terahertz free space device systems.
Monari, Paola; Pelizzari, Laura; Crotti, Silvia; Damiani, Giovanni; Calzavara-Pinton, Piergiacomo; Gualdi, Giulio
2015-11-01
PRISM (Pictorial Representation of Illness and Self Measure) is a nonverbal visualization instrument. The authors chose to use this tool to avoid the limitation of the other tests for the assessment of quality of life by using interview methods that depend on the cognitive and cultural level of the patient. The aim of the study was to assess the impact on the quality of life of different types of chronic wounds using the PRISM test. The PRISM test was administered by the same medical student to each patient visiting the dermatology department for a routine visit and medication. The PRISM test was administered to 77 patients with chronic cutaneous ulcers referred to the Dermatology Department of the Spedali Civili of Brescia, Italy. The authors analyzed the "Self-llness-Separation"' (SIS) value, which resulted from the PRISM test, and related it to sex, age, and ulcer etiology. Considering all categories, the mean SIS was 9.58 cm; a different perception of the disease between the sexes was noted and also in the subgroups based on the ulcer's different etiology. In addition, the age of the affected patients influenced the SIS value. PRISM is an easy and sensitive instrument to record information about the patient's expectations and suffering in order to improve the overall physician-patient relationship.
Design of a rear anamorphic attachment for digital cinematography
NASA Astrophysics Data System (ADS)
Cifuentes, A.; Valles, A.
2008-09-01
Digital taking systems for HDTV and now for the film industry present a particularly challenging design problem for rear adapters in general. The thick 3-channel prism block in the camera provides an important challenge in the design. In this paper the design of a 1.33x rear anamorphic attachment is presented. The new design departs significantly from the traditional Bravais condition due to the thick dichroic prism block. Design strategies for non-rotationally symmetric systems and fields of view are discussed. Anamorphic images intrinsically have a lower contrast and less resolution than their rotationally symmetric counterparts, therefore proper image evaluation must be considered. The interpretation of the traditional image quality methods applied to anamorphic images is also discussed in relation to the design process. The final design has a total track less than 50 mm, maintaining the telecentricity of the digital prime lens and taking full advantage of the f/1.4 prism block.
2013-01-01
Background An ageing population increases demand on health and social care. New approaches are needed to shift care from hospital to community and general practice. A predictive risk stratification tool (Prism) has been developed for general practice that estimates risk of an emergency hospital admission in the following year. We present a protocol for the evaluation of Prism. Methods/Design We will undertake a mixed methods progressive cluster-randomised trial. Practices begin as controls, delivering usual care without Prism. Practices will receive Prism and training randomly, and thereafter be able to use Prism with clinical and technical support. We will compare costs, processes of care, satisfaction and patient outcomes at baseline, 6 and 18 months, using routine data and postal questionnaires. We will assess technical performance by comparing predicted against actual emergency admissions. Focus groups and interviews will be undertaken to understand how Prism is perceived and adopted by practitioners and policy makers. We will model data using generalised linear models and survival analysis techniques to determine whether any differences exist between intervention and control groups. We will take account of covariates and explanatory factors. In the economic evaluation we will carry out a cost-effectiveness analysis to examine incremental cost per emergency admission to hospital avoided and will examine costs versus changes in primary and secondary outcomes in a cost-consequence analysis. We will also examine changes in quality of life of patients across the risk spectrum. We will record and transcribe focus groups and interviews and analyse them thematically. We have received full ethical and R&D approvals for the study and Information Governance Review Panel (IGRP) permission for the use of routine data. We will comply with the CONSORT guidelines and will disseminate the findings at national and international conferences and in peer-reviewed journals. Discussion The proposed study will provide information on costs and effects of Prism; how it is used in practice, barriers and facilitators to its implementation; and its perceived value in supporting the management of patients with and at risk of developing chronic conditions. Trial registration Controlled Clinical Trials ISRCTN no. ISRCTN55538212. PMID:24330749
The Behaviour of Palm Oil Fibre Block Masonry Prism under Eccentric Compressive Loading
NASA Astrophysics Data System (ADS)
Mokhtar, Mardiha; Kolop, Roslan; Baizura Hamid, Nor; Kaamin, Masiri; Farhan Rosdi, Mohd; Ngadiman, Norhayati; Sahat, Suhaila
2017-08-01
Dry-stacked masonry offers great benefits in constructing masonry buildings. Several examples from previous research show that dry masonry is reasonable alternative to the traditional building system. By addition of fibre, the ductility and the propagation of cracking will be improved. This study investigates the dry stack oil palm fibre block prisms which were subjected to eccentricity compression loads. These concrete blocks were cast using a single mould with suitable fibre-cement composition namely 1:4 (cement: sand) and 0.40 water to the cement ratio based on cement weight. Prisms test using 400 (length) × 150 (width) × 510 (height) mm specimen was carried under eccentric load. There were forty eight (48) prisms built with different configurations based on their volume of fibre. In this study, one types of grout were used namely the fine grout of mix 1:3:2 (cement: sand: aggregate (5mm maximum). Based on the test performed, the failure mechanism and influencing parameters were discussed. From compressive strength test result, it shows that the strength of concrete block decreased with the increase of fibre used. Although the control sample has the higher strength compared to concrete with EFB, it can be seen from mode failure of masonry prism that fibre could extend the cracking time. These results show that the oil palm fibre blocks can improve the failure behaviour and suitable to be used as load bearing wall construction in Malaysia.
Barry, J C; Backes, A
1998-04-01
The alternating prism and cover test is the conventional test for the measurement of the angle of strabismus. The error induced by the prismatic effect of glasses is typically about 27-30%/10 D. Alternatively, the angle of strabismus can be measured with methods based on Purkinje reflex positions. This study examines the differences between three such options, taking into account the influence of glasses. The studied system comprised the eyes with or without glasses, a fixation object and a device for recording the eye position: in the case of the alternate prism and cover test, a prism bar was required; in the case of a Purkinje reflex based device, light sources for generation of reflexes and a camera for the documentation of the reflex positions were used. Measurements performed on model eyes and computer ray traces were used to analyze and compare the options. When a single corneal reflex is used, the misalignment of the corneal axis can be measured; the error in this measurement due to the prismatic effect of glasses was 7.6%/10 D, the smallest found in this study. The individual Hirschberg ratio can be determined by monocular measurements in three gaze directions. The angle of strabismus can be measured with Purkinje reflex based methods if the fundamental differences between these methods and the alternate prism and cover test, and if the influence of glasses and other sources of error are accounted for.
[Lateral chromatic aberrations correction for AOTF imaging spectrometer based on doublet prism].
Zhao, Hui-Jie; Zhou, Peng-Wei; Zhang, Ying; Li, Chong-Chong
2013-10-01
An user defined surface function method was proposed to model the acousto-optic interaction of AOTF based on wave-vector match principle. Assessment experiment result shows that this model can achieve accurate ray trace of AOTF diffracted beam. In addition, AOTF imaging spectrometer presents large residual lateral color when traditional chromatic aberrations correcting method is adopted. In order to reduce lateral chromatic aberrations, a method based on doublet prism is proposed. The optical material and angle of the prism are optimized automatically using global optimization with the help of user defined AOTF surface. Simulation result shows that the proposed method provides AOTF imaging spectrometer with great conveniences, which reduces the lateral chromatic aberration to less than 0.000 3 degrees and improves by one order of magnitude, with spectral image shift effectively corrected.
NASA Astrophysics Data System (ADS)
Remes, Z.; Kozak, H.; Rezek, B.; Ukraintsev, E.; Babchenko, O.; Kromka, A.; Girard, H. A.; Arnault, J.-C.; Bergonzo, P.
2013-04-01
Linear antenna microwave chemical vapor deposition process was used to homogeneously coat a 7 cm long silicon prism by 85 nm thin nanocrystalline diamond (NCD) layer. To show the advantages of the NCD-coated prism for attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) of nanoparticles, we apply diamond nanoparticles (DNPs) of 5 nm nominal size with various surface modifications by a drop-casting of their methanol dispersions. ATR-FTIR spectra of as-received, air-annealed, plasma-oxidized, and plasma-hydrogenated DNPs were measured in the 4000-1500 cm-1 spectral range. The spectra show high spectral resolution, high sensitivity to specific DNP surface moieties, and repeatability. The NCD coating provides mechanical protection against scratching and chemical stability of the surface. Moreover, unlike on bare Si surface, NCD hydrophilic properties enable optically homogeneous coverage by DNPs with some aggregation on submicron scale as evidenced by scanning electron microscopy and atomic force microscopy. Compared to transmission FTIR regime with KBr pellets, direct and uniform deposition of DNPs on NCD-ATR prism significantly simplifies and speeds up the analysis (from days to minutes). We discuss prospects for in situ monitoring of surface modifications and molecular grafting.
ERIC Educational Resources Information Center
Kokebayeva, Gulzhaukhar; Smagulov, Kadyrzhan; Mussabalina, Gulnara
2016-01-01
This article attempts to address the issue of prisoners of war through the prism of international law. The object of research is the work of the Commission to investigate the Entente's complaints of violation of Hague Convention on Treatment of Prisoners of War by German authorities. After the armistice, the governments of the Entente sent notes…
High-precision angle sensor based on a Köster’s prism with absolute zero-point
NASA Astrophysics Data System (ADS)
Ullmann, V.; Oertel, E.; Manske, E.
2018-06-01
In this publication, a novel approach will be presented to use a compact white-light interferometer based on a Köster’s prism for angle measurements. Experiments show that the resolution of this angle interferometer is in the range of a commercial digital autocollimator, with a focal length of f = 300 mm, but with clearly reduced signal noise and without overshoot artifacts in the signal caused by digital filters. The angle detection of the reference mirror in the Köster’s interferometer is based on analysing the rotation angle of the fringe pattern, which is projected on a CMOS-matrix. The fringe pattern is generated by two displaced spherical wave fronts coming from one fiber-coupled white-light source and getting divided into a reference and a measurement beam by the Köster’s prism. The displacement correlates with the reference angle mirror in one linear direction and with the angle aberrations of the prism in the other orthogonal direction on the CMOS sensor. We will present the experimental and optical setup, the method and algorithms for the image-to-angle processing as well as the experimental results obtained in calibration and long-term measurements.
Convergence accommodation to convergence CA/C ratio: convergence versus divergence.
Simmons, Joshua M; Firth, Alison Y
2014-09-01
To determine whether the convergence accommodation to convergence (CA/C) ratio during divergence with base-in (BI) prisms is of a similar or different magnitude to that measured during convergence with base-out (BO) prisms. Eighteen participants with normal binocular single vision were recruited. The participants viewed a pseudo-Gaussian target, which consisted of a light emitting diode (LED) behind a diffusing screen at 40 cm. After 5 minutes of dark adaptation, the refractive status of the eye was measured without any prism using a Shin-Nippon SRW-5000 autorefractor. The participant held the selected prism (5Δ or 10Δ BO or BI, counterbalanced) in front of their right eye and obtained a single, fused image of the target while refractive measures were taken with each. A 30-second rest period was given between measurements. The mean age of the participants was 20.6±3.22 years. The mean CA/C ratios for the 5Δ BO, 10Δ BO, 5Δ BI, and 10Δ BI were 0.108 (±0.074) D/Δ, 0.110 (±0.056) D/Δ, 0.100 (±0.090) D/Δ, and 0.089 (±0.055) D/Δ, respectively. A 2-factor repeated measures ANOVA found that the CA/C ratio did not significantly change with differing levels of prism-induced convergence and divergence (p=0.649). Change in accommodation induced by manipulating vergence is similar whether convergence or divergence are induced. The CA/C ratio did not show any change with differing levels of prism-induced convergence and divergence.
NASA Astrophysics Data System (ADS)
Wu, Lifu; Zhu, Jianguo; Xie, Huimin; Zhou, Mengmeng
2016-12-01
Recently, we proposed a single-lens 3D digital image correlation (3D DIC) method and established a measurement system on the basis of a bilateral telecentric lens (BTL) and a bi-prism. This system can retrieve the 3D morphology of a target and measure its deformation using a single BTL with relatively high accuracy. Nevertheless, the system still suffers from systematic errors caused by manufacturing deficiency of the bi-prism and distortion of the BTL. In this study, in-depth evaluations of these errors and their effects on the measurement results are performed experimentally. The bi-prism deficiency and the BTL distortion are characterized by two in-plane rotation angles and several distortion coefficients, respectively. These values are obtained from a calibration process using a chessboard placed into the field of view of the system; this process is conducted after the measurement of tested specimen. A modified mathematical model is proposed, which takes these systematic errors into account and corrects them during 3D reconstruction. Experiments on retrieving the 3D positions of the chessboard grid corners and the morphology of a ceramic plate specimen are performed. The results of the experiments reveal that ignoring the bi-prism deficiency will induce attitude error to the retrieved morphology, and the BTL distortion can lead to its pseudo out-of-plane deformation. Correcting these problems can further improve the measurement accuracy of the bi-prism-based single-lens 3D DIC system.
Yi-Frazier, Joyce P; Fladeboe, Kaitlyn; Klein, Victoria; Eaton, Lauren; Wharton, Claire; McCauley, Elizabeth; Rosenberg, Abby R
2017-09-01
It is well-known that parental stress and coping impacts the well-being of children with serious illness. The current study aimed to evaluate the feasibility and satisfaction of a novel resilience promoting intervention, the Promoting Resilience in Stress Management Intervention for Parents (PRISM-P) among parents of adolescents and young adults with Type 1 diabetes or cancer. Secondary analyses explored the effect of the PRISM-P on parent-reported resilience and distress. The PRISM-P includes 4 short skills-based modules, delivered in either 2 or 4 separate, individual sessions. English-speaking parents of adolescents with cancer or Type 1 diabetes were eligible. Feasibility was conservatively defined as a completion rate of 80%; satisfaction was qualitatively evaluated based upon parent feedback regarding intervention content, timing, and format. Resilience and distress were assessed pre- and postintervention with the Connor Davidson Resilience Scale and the Kessler-6 Psychological Distress Scale. Twelve of 24 caregivers of youth with diabetes (50%) and 13 of 15 caregivers of youth with cancer (87%) agreed to participate. Nine of 12 (75%) and 9 of 13 (64%) completed all PRISM-P modules, respectively. Among those who completed the intervention, qualitative satisfaction was high. Parent-reported resilience and distress scores improved after the intervention. Effect sizes for both groups indicated a moderate intervention effect. Ultimately, the PRISM-P intervention was well accepted and impactful among parents who completed it. However, attrition rates were higher than anticipated, suggesting alternative or less time-intensive formats may be more feasible. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
An in-line optical image translator with applications in x-ray videography.
Picot, P A; Cardinal, H N; Fenster, A
1990-01-01
Many applications in radiography require, or would benefit from, the ability to translate, i.e. move, an optical image in the detector plane. In this paper, we describe the design and characterization of a prism-based optical image translator for insertion into existing XRII-video imaging systems. A pair of prisms rotatable about the optical axis form a very compact in-line optical image translator for installation in the parallel light path between an x-ray image intensifier and its video camera. Rotation of the prisms translates the XRII optical image on the camera target. With the addition of x-ray and light collimators to limit the image to a single video line, x-ray streak images may be acquired. By rotating an object in the x-ray beam during a streak, a complete computed tomography (CT) data set may be acquired. This image translator can translate an image anywhere in the focal plane of a 50-mm-output lens within a 40-mm-diam circle. The prisms have an aperture of 50 mm, permitting an optical speed of F/2 with a 50-mm output lens. The design is insensitive to angular alignment errors. This image translator is achromatic, since the spectral width of the output phosphorus of image intensifiers is sufficient to introduce blurring in a nonacrhomatic design. A prism-based image translator introduces image distortion, since the prisms do not operate at minimum deviation. The distortion is less than 4% over all parts of a typical detector area, and less than 1% in the central region of the image.(ABSTRACT TRUNCATED AT 250 WORDS)
Autonomous Navigation of USAF Spacecraft
1983-12-01
ASSEMBLY 21.LACn. THERM AL RADEARTOR ASEML 21.5 in REFERENC BASE PLATE JELECTRONICS REFERENMODULE ASSEMBLY (4 PLACES) PORRO PRISM & BASE MIRROR -24.25...involved in active satellite-to- satellite cracking for 14 days following one day of ground tracking. Earth geopotential resonance terms are the largest...rotates a prism at 9 rps such that optical signals are injected into each telescope parallel to the reielved starlight. The angle between tne two lines
NASA Astrophysics Data System (ADS)
Cardoso Dos Santos, Marcelina; Vézy, Cyrille; Jaffiol, Rodolphe
2016-02-01
Total Internal Reflection Fluorescence Microscopy (TIRFM) is a widespread technique to study cellular process occurring near the contact region with the glass substrate. In this field, determination of the accurate distance from the surface to the plasma membrane constitutes a crucial issue to investigate the physical basis of cellular adhesion process. However, quantitative interpretation of TIRF pictures regarding the distance z between a labeled membrane and the substrate is not trivial. Indeed, the contrast of TIRF images depends on several parameters more and less well known (local concentration of dyes, absorption cross section, angular emission pattern…). The strategy to get around this problem is to exploit a series of TIRF pictures recorded at different incident angles in evanescent regime. This technique called variable-angle TIRF microscopy (vaTIRFM), allowing to map the membrane-substrate separation distance with a nanometric resolution (10-20 nm). vaTIRFM was developed by Burmeister, Truskey and Reichert in the early 1990s with a prism-based TIRF setup [Journal of Microscopy 173, 39-51 (1994)]. We propose a more convenient prismless setup, which uses only a rotatable mirror to adjust precisely the laser beam on the back focal plane of the oil immersion objective (no azimuthal scanning is needed). The series of TIRF images permit us to calculate accurately membrane-surface distances in each pixel. We demonstrate that vaTIRFM are useful to quantify the adhesion of living cells for specific and unspecific membrane-surface interactions, achieved on various functionalized substrates with polymers (BSA, poly-L-lysin) or extracellular matrix proteins (collagen and fibronectin).
OCLC: Changing the Tasks of Librarianship.
ERIC Educational Resources Information Center
Smith, K. Wayne
1993-01-01
Reviews the history of OCLC and describes current and future objectives. Highlights include membership; network affiliations; cataloging services; interlibrary loan; EPIC, a new reference system; a new telecommunications network; PRISM, a new online system for cataloging and resource sharing; pricing strategies; international operations; and…
Ophthalmological outcome after resection of tumors based on the pineal gland.
Hart, Michael G; Sarkies, Nicholas J; Santarius, Thomas; Kirollos, Ramez W
2013-08-01
Descriptions of visual dysfunction in pineal gland tumors tend to focus on upward gaze palsy alone. The authors aimed to characterize the nature, incidence, and functional significance of ophthalmological dysfunction after resection of tumors based on the pineal gland. Review of a retrospective case series was performed and included consecutive patients who underwent surgery performed by a consultant neurosurgeon between 2002 and 2011. Only tumors specifically based on the pineal gland were included; tumors encroaching on the pineal gland from other regions were excluded. All patients with visual signs and/or symptoms were reviewed by a specialist consultant neuroophthalmologist to accurately characterize the nature of their deficits. Visual disturbance was defined as visual symptoms caused by a disturbance of ocular motility. A total of 20 patients underwent resection of pineal gland tumors. Complete resection was obtained in 85%, and there were no perioperative deaths. Visual disturbance was present in 35% at presentation; of those who had normal ocular motility preoperatively 82% had normal motility postoperatively. In total, 55% of patients had residual visual disturbance postoperatively. Although upward gaze tended to improve, significant functional deficits remained, particularly with regard to complex convergence and accommodation dysfunction. Prisms were used in 25% but were only ever partially effective. Visual outcome was only related to preoperative visual status and tumor volume (multivariate analysis). Long-term visual morbidity after pineal gland tumor resection is common and leads to significant functional impairment. Improvement in deficits rarely occurs spontaneously, and prisms only have limited effectiveness, probably due to the dynamic nature of supranuclear ocular movement coordination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardiansyah, D.; Haryanto, F.; Male, S.
2014-09-30
Prism is a non-commercial Radiotherapy Treatment Planning System (RTPS) develop by Ira J. Kalet from Washington University. Inhomogeneity factor is included in Prism TPS dose calculation. The aim of this study is to investigate the sensitivity of dose calculation on Prism using Monte Carlo simulation. Phase space source from head linear accelerator (LINAC) for Monte Carlo simulation is implemented. To achieve this aim, Prism dose calculation is compared with EGSnrc Monte Carlo simulation. Percentage depth dose (PDD) and R50 from both calculations are observed. BEAMnrc is simulated electron transport in LINAC head and produced phase space file. This file ismore » used as DOSXYZnrc input to simulated electron transport in phantom. This study is started with commissioning process in water phantom. Commissioning process is adjusted Monte Carlo simulation with Prism RTPS. Commissioning result is used for study of inhomogeneity phantom. Physical parameters of inhomogeneity phantom that varied in this study are: density, location and thickness of tissue. Commissioning result is shown that optimum energy of Monte Carlo simulation for 6 MeV electron beam is 6.8 MeV. This commissioning is used R50 and PDD with Practical length (R{sub p}) as references. From inhomogeneity study, the average deviation for all case on interest region is below 5 %. Based on ICRU recommendations, Prism has good ability to calculate the radiation dose in inhomogeneity tissue.« less
NASA Astrophysics Data System (ADS)
Sabitov, L. S.; Kashapov, N. F.; Gilmanshin, I. R.; Strelkov, Yu M.; Khusainov, D. M.
2017-09-01
The development is demountable foundation for support, including separate reinforced concrete blocks in the form of prisms mounted on the surface of the base and pulled together by horizontal strands, and anchor devices for fixing the supports. The reinforced concrete blocks are made in the form of hollow prisms consisting of walls and square bottoms, and the strands are made in the form of bolts that tighten the walls along the top and bottom, while the anchoring devices for fixing the supports are made in the form of anchors on the bottom of the central prism and horizontal spacers between the support and the walls of the prism in its upper part. Numerical studies of the foundation have been carried out and its optimal sizes have been found in the PK Lira SAPR.
Accretionary processes along the Middle America Trench off Costa Rica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shipley, T.H.; Stoffa, P.L.; McIntosh, K.
1990-06-01
The geometry of large-scale structures within modern accretionary prisms is known entirely from seismic reflection studies using single or grids of two-dimensional profiles. Off Costa Rica the authors collected a three-dimensional reflection data set covering a 9 km wide {times} 22 km long {times} 6 km thick volume of the accretionary prism just arcward of the Middle America Trench. The three-dimensional processing and ability to examine the prism as a volume has provided the means to map structures from a few hundred meters to kilometers in size with confidence. Reflections from within the prism define the gross structural features andmore » tectonic processes active along this particular portion of the Middle America Trench. So far in the analysis, these data illustrate the relationships between the basement, the prism shape, and overlying slope sedimentary deposits. For instance, the subducted basement relief (of several hundred meters amplitude) does seem to affect the larger scale through-going faults within the prism. Offscraping of the uppermost 45 m of sediments occurs within 4 km of the trench creating a small pile of sediments at the base of the trench. How this offscraped sediment is incorporated into the prism is still being investigated. Underplating of parts of the 400 m thick subducted section begin: at a very shallow structural level, 4 to 10 km arcward of the trench. Amplitude anomalies associated with some of the larger arcward dipping structures in the prism and surface mud volcanoes suggest that efficient fluid migration paths may extend from the top of the downgoing slab at the shelf edge out into the lower and middle slope region, a distance of 50 to 100 km.« less
Direct AFM observation of an opening event of a DNA cuboid constructed via a prism structure.
Endo, Masayuki; Hidaka, Kumi; Sugiyama, Hiroshi
2011-04-07
A cuboid structure was constructed using a DNA origami design based on a square prism structure. The structure was characterized by atomic force microscopy (AFM) and dynamic light scattering. The real-time opening event of the cuboid was directly observed by high-speed AFM.
Hamada, Yohei; Kitamura, Manami; Yamada, Yasuhiro; Sanada, Yoshinori; Sugihara, Takamitsu; Saito, Saneatsu; Moe, Kyaw; Hirose, Takehiro
2018-02-14
A new method for evaluating the in situ rock strength beneath the seafloor is proposed and applied to the Nankai Trough accretionary prism. The depth-continuous in situ rock strength is a critical parameter for numerous studies in earth science, particularly for seismology and tectonics at plate convergence zones; yet, measurements are limited owing to a lack of drilled cores. Here, we propose a new indicator of strength, the equivalent strength (EST), which is determined only by drilling performance parameters such as drill string rotational torque, bit depth, and string rotational speed. A continuous depth profile of EST was drawn from 0 to 3000 m below the seafloor (mbsf) across the forearc basin and accretionary prism in the Nankai Trough. The EST did not show a significant increase around the forearc basin-accretionary prism boundary, but it did show a clear increase within the prism, ca. below 1500 mbsf. This result may indicate that even the shallow accretionary prism has been strengthened by horizontal compression derived from plate subduction. The EST is a potential parameter to continuously evaluate the in situ rock strength during drilling, and its accuracy of the absolute value can be improved by combining with laboratory drilling experiments.
A novel and compact spectral imaging system based on two curved prisms
NASA Astrophysics Data System (ADS)
Nie, Yunfeng; Bin, Xiangli; Zhou, Jinsong; Li, Yang
2013-09-01
As a novel detection approach which simultaneously acquires two-dimensional visual picture and one-dimensional spectral information, spectral imaging offers promising applications on biomedical imaging, conservation and identification of artworks, surveillance of food safety, and so forth. A novel moderate-resolution spectral imaging system consisting of merely two optical elements is illustrated in this paper. It can realize the function of a relay imaging system as well as a 10nm spectral resolution spectroscopy. Compared to conventional prismatic imaging spectrometers, this design is compact and concise with only two special curved prisms by utilizing two reflective surfaces. In contrast to spectral imagers based on diffractive grating, the usage of compound-prism possesses characteristics of higher energy utilization and wider free spectral range. The seidel aberration theory and dispersive principle of this special prism are analyzed at first. According to the results, the optical system of this design is simulated, and the performance evaluation including spot diagram, MTF and distortion, is presented. In the end, considering the difficulty and particularity of manufacture and alignment, an available method for fabrication and measurement is proposed.
A collection of edge-based elements
NASA Technical Reports Server (NTRS)
Kempel, Leo C.; Volakis, John L.
1992-01-01
Edge-based elements have proved useful in solving electromagnetic problems since they are nondivergent. Previous authors have presented several two and three dimensional elements. Herein, we present four types of elements which are suitable for modeling several types of three dimensional geometries. Distorted brick and triangular prism elements are given in cartesian coordinates as well as the specialized cylindrical shell and pie-shaped prism elements which are suitable for problems best described in polar cylindrical coordinates.
Double wedge prism based beam deflector for precise laser beam steering
NASA Astrophysics Data System (ADS)
Tyszka, Krzysztof; Dobosz, Marek; Bilaszewski, Tomasz
2018-02-01
Aiming to increase laser beam pointing stability required in interferometric measurements, we designed a laser beam deflector intended for active laser beam stabilization systems. The design is based on two wedge-prisms: the deflecting wedge driven by a tilting piezo-platform and the fixed wedge to compensate initial beam deflection. Our design allows linear beam steering, independently in the horizontal or vertical direction, with resolution of less than 1 μrad in a range of more than 100 μrad, and no initial deflection of the beam. Moreover, the ratio of the output beam deflection angle and the wedge tilt angle is less than 0.1; therefore, the noise influence is significantly reduced in comparison to standard mirror-based deflectors. The theoretical analyses support the designing process and can serve as a guide to wedge-prism selection. The experimental results are in agreement with theory and confirm the advantages of the presented double wedge system.
Prism adaptation for spatial neglect after stroke: translational practice gaps.
Barrett, A M; Goedert, Kelly M; Basso, Julia C
2012-10-01
Spatial neglect increases hospital morbidity and costs in around 50% of the 795,000 people per year in the USA who survive stroke, and an urgent need exists to reduce the care burden of this condition. However, effective acute treatment for neglect has been elusive. In this article, we review 48 studies of a treatment of intense neuroscience interest: prism adaptation training. Due to its effects on spatial motor 'aiming', prism adaptation training may act to reduce neglect-related disability. However, research failed, first, to suggest methods to identify the 50-75% of patients who respond to treatment; second, to measure short-term and long-term outcomes in both mechanism-specific and functionally valid ways; third, to confirm treatment utility during the critical first 8 weeks poststroke; and last, to base treatment protocols on systematic dose-response data. Thus, considerable investment in prism adaptation research has not yet touched the fundamentals needed for clinical implementation. We suggest improved standards and better spatial motor models for further research, so as to clarify when, how and for whom prism adaptation should be applied.
Prism adaptation for spatial neglect after stroke: translational practice gaps
Barrett, A. M.; Goedert, Kelly M.; Basso, Julia C.
2012-01-01
Spatial neglect increases hospital morbidity and costs in around 50% of the 795,000 people per year in the USA who survive stroke, and an urgent need exists to reduce the care burden of this condition. However, effective acute treatment for neglect has been elusive. In this article, we review 48 studies of a treatment of intense neuroscience interest: prism adaptation training. Due to its effects on spatial motor ‘aiming’, prism adaptation training may act to reduce neglect-related disability. However, research failed, first, to suggest methods to identify the 50–75% of patients who respond to treatment; second, to measure short-term and long-term outcomes in both mechanism-specific and functionally valid ways; third, to confirm treatment utility during the critical first 8 weeks poststroke; and last, to base treatment protocols on systematic dose–response data. Thus, considerable investment in prism adaptation research has not yet touched the fundamentals needed for clinical implementation. We suggest improved standards and better spatial motor models for further research, so as to clarify when, how and for whom prism adaptation should be applied. PMID:22926312
1975-08-01
prism adjustment screw 12 - 45° prism adjustment lockscrew 13-45° prism 14 - Porro prism 15 - Collimating telescope X-axis adjustment lockscrew...4) 16 - Q-switch tilt adjustment screw 17 - Q-switch tilt adjustment lockscrew (4) 18 - Porro prism adjustment nut (3) 19 - Porro prism mounting...is increased by several orders of magnitude. "Q" switch technology has progressed from rotating prisms or mirrors to electro-optical (E/0
Harbauer, Gregor; Ring, Mariann; Schuetz, Christopher; Andreae, Andreas; Haas, Sebastian
2013-01-01
The PRISM-S task was developed at the Crisis Intervention Center (KIZ) Winterthur, Switzerland, to enable an assessment of the degree of suicidality in less than 5 minutes with a simple, visual instrument. Comparison of validity and clinical use of the new PRISM-S task with other instruments known as "gold standards". Quantitative pilot study enlisting 100 inpatients admitted to the KIZ, aged 15-42 years. Patients' suicidality was assessed by the PRISM-S task during the first clinical interview and compared to data obtained by standardized suicidality instruments. The patients completed the PRISM-S task in 2 to 5 minutes without difficulty. Data show significant positive correlations between the suicidality as assessed by PRISM-S and the gold standards, i.e., DSI-SS (r = 0.59, N = 65, p < .0001). There is no strong evidence that PRISM-S is useful for outpatients or in other settings. The experiences gained with outpatients/patients with other disorders are promising but have not been systematically evaluated. The results do not rely on a randomized design. The sample consists of persons coming to the crisis intervention center. PRISM-S offers a brief, easy-to-administer, and valid method to assess patients' suicidality. The simple instruction facilitates its use in other languages and other cultures as well. The acceptance by patients and health professionals was good, with no one refusing to complete the task.
Optical switch using Risley prisms
Sweatt, William C.; Christenson, Todd R.
2003-04-15
An optical switch using Risley prisms and rotary microactuators to independently rotate the wedge prisms of each Risley prism pair is disclosed. The optical switch comprises an array of input Risley prism pairs that selectively redirect light beams from a plurality of input ports to an array of output Risley prism pairs that similarly direct the light beams to a plurality of output ports. Each wedge prism of each Risley prism pair can be independently rotated by a variable-reluctance stepping rotary microactuator that is fabricated by a multi-layer LIGA process. Each wedge prism can be formed integral to the annular rotor of the rotary microactuator by a DXRL process.
Optical Switch Using Risley Prisms
Sweatt, William C.; Christenson, Todd R.
2005-02-22
An optical switch using Risley prisms and rotary microactuators to independently rotate the wedge prisms of each Risley prism pair is disclosed. The optical switch comprises an array of input Risley prism pairs that selectively redirect light beams from a plurality of input ports to an array of output Risley prism pairs that similarly direct the light beams to a plurality of output ports. Each wedge prism of each Risley prism pair can be independently rotated by a variable-reluctance stepping rotary microactuator that is fabricated by a multi-layer LIGA process. Each wedge prism can be formed integral to the annular rotor of the rotary microactuator by a DXRL process.
What is the value of conducting a trial of r-tPA for the treatment of mild stroke patients?
Guzauskas, Gregory F; Chen, Er; Lalla, Deepa; Yu, Elaine; Tayama, Darren; Veenstra, David L
2017-02-01
Background The Phase IIIb, Double-Blind, Multicenter Study to Evaluate the Efficacy and Safety of Alteplase in Patients With Mild Stroke: Rapidly Improving Symptoms and Minor Neurologic Deficits (PRISMS) trial will assess r-tPA in ischemic stroke patients who present with mild deficits (i.e. mild stroke). Aims To assess PRISMS's societal value in clarifying the optimal care for patients with mild ischemic stroke. Methods A value of information (VOI) decision model was developed to compare the outcomes of mild stroke patients treated vs. not treated with r-tPA. Model inputs were derived from a subset of Third International Stroke Trial patients, a recent meta-analysis of r-tPA trials, expert opinion, and other published sources. VOI analyses were also used to assess the expected US societal value of the PRISMS trial and the expected value of reducing uncertainty in key trial estimates. Results The expected net societal value of the PRISMS trial was approximately $210 million ($160 m-$260 m), representing a six-fold return on investment. The value of reducing uncertainty in r-tPA efficacy was approximately $150 million ($100 m-$200 m), while reducing uncertainty in r-tPA safety (increased risk for symptomatic intracranial hemorrhage) did not add additional value in comparison. Conclusions Developing a better understanding of the outcomes of r-tPA treatment in patients with mild ischemic stroke will provide tremendous societal value by clarifying current uncertainty around treatment effectiveness. Enrollment in the PRISMS trial for patients presenting with mild ischemic stroke within 0-3 h of symptom onset should be highly encouraged.
Foot placement relies on state estimation during visually guided walking.
Maeda, Rodrigo S; O'Connor, Shawn M; Donelan, J Maxwell; Marigold, Daniel S
2017-02-01
As we walk, we must accurately place our feet to stabilize our motion and to navigate our environment. We must also achieve this accuracy despite imperfect sensory feedback and unexpected disturbances. In this study we tested whether the nervous system uses state estimation to beneficially combine sensory feedback with forward model predictions to compensate for these challenges. Specifically, subjects wore prism lenses during a visually guided walking task, and we used trial-by-trial variation in prism lenses to add uncertainty to visual feedback and induce a reweighting of this input. To expose altered weighting, we added a consistent prism shift that required subjects to adapt their estimate of the visuomotor mapping relationship between a perceived target location and the motor command necessary to step to that position. With added prism noise, subjects responded to the consistent prism shift with smaller initial foot placement error but took longer to adapt, compatible with our mathematical model of the walking task that leverages state estimation to compensate for noise. Much like when we perform voluntary and discrete movements with our arms, it appears our nervous systems uses state estimation during walking to accurately reach our foot to the ground. Accurate foot placement is essential for safe walking. We used computational models and human walking experiments to test how our nervous system achieves this accuracy. We find that our control of foot placement beneficially combines sensory feedback with internal forward model predictions to accurately estimate the body's state. Our results match recent computational neuroscience findings for reaching movements, suggesting that state estimation is a general mechanism of human motor control. Copyright © 2017 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Webb, S. I.; Tudge, J.; Tobin, H. J.
2013-12-01
Integrated Ocean Drilling Program (IODP) Expedition 338, the most recently completed drilling stage of the NanTroSEIZE project, targeted the Miocene inner accretionary prism off the coast of southwest Japan. NanTroSEIZE is a multi-stage project in which the main objective is to characterize, sample, and instrument the potentially seismogenic region of the Nankai Trough, an active subduction zone. Understanding the physical properties of the inner accretionary prism will aid in the characterization of the deformation that has taken place and the evolution of stress, fluid pressure, and strain over the deformational history of these sediments and rocks. This study focuses on the estimation of porosity and density from available logs to inform solid and fluid volume estimates at Site C0002 from the sea floor through the Kumano Basin into the accretionary prism. Gamma ray, resistivity, and sonic logs were acquired at Hole C0002F, to a total depth of 2005 mbsf into the inner accretionary prism. Because a density and neutron porosity tool could not be deployed, porosity and density must be estimated using a variety of largely empirical methods. In this study, we calculate estimated porosity and density from both the electrical resistivity and sonic (P-wave velocity) logs collected in Hole C0002F. However, the relationship of these physical properties to the available logs is not straightforward and can be affected by changes in fluid type, salinity, temperature, presence of fractures, and clay mineralogy. To evaluate and calibrate the relationships among these properties, we take advantage of the more extensive suite of LWD data recorded in Hole C0002A at the same drill site, including density and neutron porosity measurements. Data collected in both boreholes overlaps in the interval from 875 - 1400 mbsf in the lower Kumano Basin and across the basin-accretionary wedge boundary. Core-based physical properties are also available across this interval. Through comparison of density and porosity values in intervals where core and LWD data overlap, we calculate porosity and density values and evaluate their uncertainties, developing a best estimate given the specific lithology and pore fluid at this tectonic setting. We then propagate this calibrated estimate to the deeper portions of C0002F where core and LWD density and porosity measurements are unavailable, using the sonic and resistivity data alone.
Design of a concise Féry-prism hyperspectral imaging system based on multi-configuration
NASA Astrophysics Data System (ADS)
Dong, Wei; Nie, Yun-feng; Zhou, Jin-song
2013-08-01
In order to meet the needs of space borne and airborne hyperspectral imaging system for light weight, simplification and high spatial resolution, a novel design of Féry-prism hyperspectral imaging system based on Zemax multi-configuration method is presented. The novel structure is well arranged by analyzing optical monochromatic aberrations theoretically, and the optical structure of this design is concise. The fundamental of this design is Offner relay configuration, whereas the secondary mirror is replaced by Féry-prism with curved surfaces and a reflective front face. By reflection, the light beam passes through the Féry-prism twice, which promotes spectral resolution and enhances image quality at the same time. The result shows that the system can achieve light weight and simplification, compared to other hyperspectral imaging systems. Composed of merely two spherical mirrors and one achromatized Féry-prism to perform both dispersion and imaging functions, this structure is concise and compact. The average spectral resolution is 6.2nm; The MTFs for 0.45~1.00um spectral range are greater than 0.75, RMSs are less than 2.4um; The maximal smile is less than 10% pixel, while the keystones is less than 2.8% pixel; image quality approximates the diffraction limit. The design result shows that hyperspectral imaging system with one modified Féry-prism substituting the secondary mirror of Offner relay configuration is feasible from the perspective of both theory and practice, and possesses the merits of simple structure, convenient optical alignment, and good image quality, high resolution in space and spectra, adjustable dispersive nonlinearity. The system satisfies the requirements of airborne or space borne hyperspectral imaging system.
Compact Packaging of Photonic Millimeter-Wave Receiver
NASA Technical Reports Server (NTRS)
Nguyen, Hung; Pouch, John; Miranda, Felix; Levi, Anthony F.
2007-01-01
A carrier structure made from a single silicon substrate is the basis of a compact, lightweight, relatively inexpensive package that holds the main optical/electronic coupling components of a photonic millimeter-wave receiver based on a lithium niobate resonator disk. The design of the package is simple and provides for precise relative placement of optical components, eliminating the need for complex, bulky positioning mechanisms like those commonly used to align optical components to optimize focus and coupling. Although a prototype of the package was fabricated as a discrete unit, the design is amenable to integration of the package into a larger photonic and/or electronic receiver system. The components (see figure) include a lithium niobate optical resonator disk of 5-mm diameter and .200- m thickness, positioned adjacent to a millimeter- wave resonator electrode. Other components include input and output coupling prisms and input and output optical fibers tipped with ball lenses for focusing and collimation, respectively. Laser light is introduced via the input optical fiber and focused into the input coupling prism. The input coupling prism is positioned near (but not in contact with) the resonator disk so that by means of evanescent-wave coupling, the input laser light in the prism gives rise to laser light propagating circumferentially in guided modes in the resonator disk. Similarly, a portion of the circumferentially propagating optical power is extracted from the disk by evanescent-wave coupling from the disk to the output coupling prism, from whence the light passes through the collimating ball lens into the output optical fiber. The lens-tipped optical fibers must be positioned at a specified focal distance from the prisms. The optical fibers and the prisms must be correctly positioned relative to the resonator disk and must be oriented to obtain the angle of incidence (55 in the prototype) required for evanescent-wave coupling of light into and out of the desired guided modes in the resonator disk. To satisfy all these requirements, precise alignment features are formed in the silicon substrate by use of a conventional wet-etching process. These features include a 5-mm-diameter, 50- m-deep cavity that holds the disk; two trapezoidal-cross-section recesses for the prisms; and two grooves that hold the optical fibers at the correct positions and angles relative to the prisms and disk. The fiber grooves contain abrupt tapers, near the prisms, that serve as hard stops for positioning the lenses at the focal distance from the prisms. There are also two grooves for prismadjusting rods. The design provides a little slack in the prism recesses for adjusting the positions of the prisms by means of these rods to optimize the optical coupling.
Foreword: Contributions of Arctic PRISM to monitoring western hemispheric shorebirds
Skagen, Susan K.; Smith, Paul A.; Andres, Brad A.; Donaldson, Garry; Brown, Stephen; Bart, Jonathan R.; Johnston, Victoria H.
2012-01-01
Long-term monitoring of populations is of paramount importance to understanding responses of organisms to global environmental change and to evaluating whether conservation practices are yielding intended results through time (Wiens 2009). The population status of many shorebird species, the focus of this volume, remain poorly known. Long-distance migrant shorebirds have proven particularly difficult to monitor, in part because of their highly inaccessible regions. As migrant shorebirds travel the length of the hemisphere, the congregate and disperse in ways that vary among species, locations, and years, presenting serious challenges to designing and implementing monitoring programs. Rigorous field and quantitative methods that estimate population size and monitor trends are vitally needed to direct and evaluate effective conservation measures. Many management efforts depend on unbiased population size estimates; for examples, the shorebird conservation plans for both Canada and the United States seek to restore populations to levels calculated for the 1970s based on the best information available from existing surveys. Further, federal wildlife agencies within the United States and Canada have mandates to understand the state of their nations' resources under various conventions for the protection of migratory birds. Accurate estimates of population size are vital statistics for a variety of conservation activities, such as prioritizing species for conservation action and setting management targets. Areas of essential habitat, such as those designated under the Western Hemisphere Shorebird Reserve Network, the Important Bird Areas program of BirdLife Internationals and the National Audubon Society, or Canada's National Wildlife Areas program, are all evaluated on the basis of proportions of species' populations which they contain. The size, and trends in size, of a species' population are considered key information for assessing its vulnerability and subsequent listing under the U.S. Endangered Species Act and the Canadian Species at Risk Act. To meet the need for information on population size and trends, shorebird biologists from Canada and the United States proposed a shared blueprint for shorebird monitoring across the Western Hemisphere in the late 1990s; this effort was undertaken in concert with the development of the Canadian and the U.S. Shorebird Conservation Plans. Soon thereafter, partners in the monitoring effort adopted the name "Program for Regional and International Shorebird Monitoring" (PRISM). Among the primary objectives of PRISM were to estimate the population sizes and trends of breeding North American shorebirds and describe their distributions. PRISM members evaluated ongoing and potential monitoring approached to address 74 taxa (including subspecies) and proposed a combination of arctic and boreal breeding surveys, temperate breeding and non-breeding surveys, and neotropical surveys.
Interference of conically scattered light in surface plasmon resonance.
Webster, Aaron; Vollmer, Frank
2013-02-01
Surface plasmon polaritons on thin metal films are a well studied phenomena when excited using prism coupled geometries such as the Kretschmann attenuated total reflection configuration. Here we describe a novel interference pattern in the conically scattered light emanating from such a configuration when illuminated by a focused beam. We observe conditions indicating only self-interference of scattered surface plasmon polaritions without any contributions from specular reflection. The spatial evolution of this field is described in the context of Fourier optics and has applications in highly sensitive surface plasmon based biosensing.
Liang, Gaoling; Luo, Zewei; Liu, Kunping; Wang, Yimin; Dai, Jianxiong; Duan, Yixiang
2016-05-03
Fiber optic-based biosensors with surface plasmon resonance (SPR) technology are advanced label-free optical biosensing methods. They have brought tremendous progress in the sensing of various chemical and biological species. This review summarizes four sensing configurations (prism, grating, waveguide, and fiber optic) with two ways, attenuated total reflection (ATR) and diffraction, to excite the surface plasmons. Meanwhile, the designs of different probes (U-bent, tapered, and other probes) are also described. Finally, four major types of biosensors, immunosensor, DNA biosensor, enzyme biosensor, and living cell biosensor, are discussed in detail for their sensing principles and applications. Future prospects of fiber optic-based SPR sensor technology are discussed.
Kondo, Takuya; Nomura, Kouji; Gemmei-Ide, Makoto; Kitano, Hiromi; Noguchi, Hidenori; Uosaki, Kohei; Saruwatari, Yoshiyuki
2014-01-01
A copolymer film composed of zwitterionic carboxymethylbetaine (CMB) and n-butyl methacrylate (BMA), Poly(CMB-r-BMA), was cast on a flat plane of an octadecyltrichlorosilane (ODS)-modified fused quartz prism with a semi-cylindrical shape. CH stretching of the polymer film and O-H stretching of water at the surface of the film were examined using the sum frequency generation (SFG) technique. The C-H stretching band of the cast film, indicating a gauche defect of the film, was affected by the contact medium including dry nitrogen, water vapor-saturated nitrogen and liquid water. In contrast, the C-H stretching of an octadecyl group introduced onto the quartz prism for stable attachment of the cast film was not significantly changed by the contact medium. The O-H stretching band indicated that water molecules at the surface of the Poly(CMB-r-BMA) film in contact with liquid water were not greatly oriented in comparison with those at the surfaces of a bare prism, an ODS SAM-modified prism, and a prism covered with a PolyBMA film or a copolymer film of BMA and methacrylic acid or 2-(dimethylamino)ethyl methacrylate. A similar small perturbation of the structure of water was previously observed in the vicinity of water-soluble zwitterionic polymers and zwitterionic copolymer films using Raman and attenuated total reflection infrared spectroscopies, respectively. A distinct effect of charge neutralization to diminish the perturbation of the structure of interfacial water around polymer materials was suggested. Copyright © 2013 Elsevier B.V. All rights reserved.
Correction of Single Frequency Altimeter Measurements for Ionosphere Delay
NASA Technical Reports Server (NTRS)
Schreiner, William S.; Markin, Robert E.; Born, George H.
1997-01-01
This study is a preliminary analysis of the accuracy of various ionosphere models to correct single frequency altimeter height measurements for Ionospheric path delay. In particular, research focused on adjusting empirical and parameterized ionosphere models in the parameterized real-time ionospheric specification model (PRISM) 1.2 using total electron content (TEC) data from the global positioning system (GPS). The types of GPS data used to adjust PRISM included GPS line-of-sight (LOS) TEC data mapped to the vertical, and a grid of GPS derived TEC data in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by IRI-90, a climatotogical model, were compared to TOPEX/Poseidon (T/P) TEC measurements from the dual-frequency altimeter for a number of T/P tracks. When adjusted with GPS LOS data, the PRISM empirical model predicted TEC over 24 1 h data sets for a given local time to with in a global error of 8.60 TECU rms during a midnight centered ionosphere and 9.74 TECU rms during a noon centered ionosphere. Using GPS derived sun-fixed TEC data, the PRISM parameterized model predicted TEC within an error of 8.47 TECU rms centered at midnight and 12.83 TECU rms centered at noon. From these best results, it is clear that the proposed requirement of 3-4 TECU global rms for TOPEX/Poseidon Follow-On will be very difficult to meet, even with a substantial increase in the number of GPS ground stations, with any realizable combination of the aforementioned models or data assimilation schemes.
Functional Mapping of the Lectin Activity Site on the β-Prism Domain of Vibrio cholerae Cytolysin
Rai, Anand Kumar; Paul, Karan; Chattopadhyay, Kausik
2013-01-01
Vibrio cholerae cytolysin (VCC) is a prominent member in the family of β-barrel pore-forming toxins. It induces lysis of target eukaryotic cells by forming transmembrane oligomeric β-barrel channels. VCC also exhibits prominent lectin-like activity in interacting with β1-galactosyl-terminated glycoconjugates. Apart from the cytolysin domain, VCC harbors two lectin-like domains: the β-Trefoil and the β-Prism domains; however, precise contribution of these domains in the lectin property of VCC is not known. Also, role(s) of these lectin-like domains in the mode of action of VCC remain obscure. In the present study, we show that the β-Prism domain of VCC acts as the structural scaffold to determine the lectin activity of the protein toward β1-galactosyl-terminated glycoconjugates. Toward exploring the physiological implication of the β-Prism domain, we demonstrate that the presence of the β-Prism domain-mediated lectin activity is crucial for an efficient interaction of the toxin toward the target cells. Our results also suggest that such lectin activity may act to regulate the oligomerization ability of the membrane-bound VCC toxin. Based on the data presented here, and also consistent with the existing structural information, we propose a novel mechanism of regulation imposed by the β-Prism domain's lectin activity, implicated in the process of membrane pore formation by VCC. PMID:23209283
Generation of a high-accuracy regional DEM based on ALOS/PRISM imagery of East Antarctica
NASA Astrophysics Data System (ADS)
Shiramizu, Kaoru; Doi, Koichiro; Aoyama, Yuichi
2017-12-01
A digital elevation model (DEM) is used to estimate ice-flow velocities for an ice sheet and glaciers via Differential Interferometric Synthetic Aperture Radar (DInSAR) processing. The accuracy of DInSAR-derived displacement estimates depends upon the accuracy of the DEM. Therefore, we used stereo optical images, obtained with a panchromatic remote-sensing instrument for stereo mapping (PRISM) sensor mounted onboard the Advanced Land Observing Satellite (ALOS), to produce a new DEM ("PRISM-DEM") of part of the coastal region of Lützow-Holm Bay in Dronning Maud Land, East Antarctica. We verified the accuracy of the PRISM-DEM by comparing ellipsoidal heights with those of existing DEMs and values obtained by satellite laser altimetry (ICESat/GLAS) and Global Navigation Satellite System surveying. The accuracy of the PRISM-DEM is estimated to be 2.80 m over ice sheet, 4.86 m over individual glaciers, and 6.63 m over rock outcrops. By comparison, the estimated accuracy of the ASTER-GDEM, widely used in polar regions, is 33.45 m over ice sheet, 14.61 m over glaciers, and 19.95 m over rock outcrops. For displacement measurements made along the radar line-of-sight by DInSAR, in conjunction with ALOS/PALSAR data, the accuracy of the PRISM-DEM and ASTER-GDEM correspond to estimation errors of <6.3 mm and <31.8 mm, respectively.
Temperate non-breeding surveys - a key to shorebird conservation
Sue Thomas
2005-01-01
Completion of the United States and Canadian shorebird conservation plans recently identified and prioritized shorebird monitoring, management, and conservation needs in the Western Hemisphere. We present an emerging approach to monitor shorebird use of temperate non-breeding areas under the Program for Regional and International Shorebird Monitoring (PRISM). This...
Comparing OECD Educational Models through the Prism of PISA
ERIC Educational Resources Information Center
Bulle, Nathalie
2011-01-01
The PISA survey influences educational policies through an international competitive process which is not wholly rationally-oriented. Firstly, PISA league tables act normatively upon the definition of formal educational aims while the survey tests cannot evaluate the educational systems' relative strengths with regards to such aims. We argue that…
Cerebellar inactivation impairs memory of learned prism gaze-reach calibrations.
Norris, Scott A; Hathaway, Emily N; Taylor, Jordan A; Thach, W Thomas
2011-05-01
Three monkeys performed a visually guided reach-touch task with and without laterally displacing prisms. The prisms offset the normally aligned gaze/reach and subsequent touch. Naive monkeys showed adaptation, such that on repeated prism trials the gaze-reach angle widened and touches hit nearer the target. On the first subsequent no-prism trial the monkeys exhibited an aftereffect, such that the widened gaze-reach angle persisted and touches missed the target in the direction opposite that of initial prism-induced error. After 20-30 days of training, monkeys showed long-term learning and storage of the prism gaze-reach calibration: they switched between prism and no-prism and touched the target on the first trials without adaptation or aftereffect. Injections of lidocaine into posterolateral cerebellar cortex or muscimol or lidocaine into dentate nucleus temporarily inactivated these structures. Immediately after injections into cortex or dentate, reaches were displaced in the direction of prism-displaced gaze, but no-prism reaches were relatively unimpaired. There was little or no adaptation on the day of injection. On days after injection, there was no adaptation and both prism and no-prism reaches were horizontally, and often vertically, displaced. A single permanent lesion (kainic acid) in the lateral dentate nucleus of one monkey immediately impaired only the learned prism gaze-reach calibration and in subsequent days disrupted both learning and performance. This effect persisted for the 18 days of observation, with little or no adaptation.
Cerebellar inactivation impairs memory of learned prism gaze-reach calibrations
Hathaway, Emily N.; Taylor, Jordan A.; Thach, W. Thomas
2011-01-01
Three monkeys performed a visually guided reach-touch task with and without laterally displacing prisms. The prisms offset the normally aligned gaze/reach and subsequent touch. Naive monkeys showed adaptation, such that on repeated prism trials the gaze-reach angle widened and touches hit nearer the target. On the first subsequent no-prism trial the monkeys exhibited an aftereffect, such that the widened gaze-reach angle persisted and touches missed the target in the direction opposite that of initial prism-induced error. After 20–30 days of training, monkeys showed long-term learning and storage of the prism gaze-reach calibration: they switched between prism and no-prism and touched the target on the first trials without adaptation or aftereffect. Injections of lidocaine into posterolateral cerebellar cortex or muscimol or lidocaine into dentate nucleus temporarily inactivated these structures. Immediately after injections into cortex or dentate, reaches were displaced in the direction of prism-displaced gaze, but no-prism reaches were relatively unimpaired. There was little or no adaptation on the day of injection. On days after injection, there was no adaptation and both prism and no-prism reaches were horizontally, and often vertically, displaced. A single permanent lesion (kainic acid) in the lateral dentate nucleus of one monkey immediately impaired only the learned prism gaze-reach calibration and in subsequent days disrupted both learning and performance. This effect persisted for the 18 days of observation, with little or no adaptation. PMID:21389311
ERIC Educational Resources Information Center
Tekin-Sitrava, Reyhan; Isiksal-Bostan, Mine
2018-01-01
This study investigated middle school teachers' knowledge of students' misconceptions and the sources of these misconceptions related to the volume of prisms. This case study investigated four middle school teachers who taught 8th grade students in Ankara (Turkey). Based on the analysis of the data, two misconceptions related to the volume of…
Ring, Mariann; Harbauer, Gregor; Haas, Sebastian; Schuetz, Christopher; Andreae, Andreas; Maercker, Andreas; Ajdacic-Gross, Vladeta
2014-01-01
In routine clinical practice the assessment of suicidality proves to be difficult and complex. The aim of the present study was to examine if PRISM can be used to measure validly the person's subjectively perceived suicidality. The nonverbal visualization technique PRISM (Pictoral Representation of Illness and Self Measure) has been developed by Büchi et al. (2002) to evaluate the perceived burden of suffering due to physical illness. The adapted version of PRISM used in our study is called PRISM-S (Pictoral Representation of Illness and Self Measure - Suicidality). 156 eligible inpatients, admitted voluntarily to the crisis intervention centre Winterthur, participated in the study. We used as gold standards the well established assessment tools the Beck Scale of Suicide Ideation (BSS) and the Depressive Symptome Inventory - Subscale (DSI-SS). The results showed high correlations between PRISM-S and the BSS (r = - 0,73) and the DSI-SS scores (r = - 0,76). Clinicians, general practitioners, psychiatrists and psychologists receive with PRISM-S a valid suicidality assessment tool that is very brief and easy to administer in clinical settings.
Performance of PRISM III and PELOD-2 scores in a pediatric intensive care unit.
Gonçalves, Jean-Pierre; Severo, Milton; Rocha, Carla; Jardim, Joana; Mota, Teresa; Ribeiro, Augusto
2015-10-01
The study aims were to compare two models (The Pediatric Risk of Mortality III (PRISM III) and Pediatric Logistic Organ Dysfunction (PELOD-2)) for prediction of mortality in a pediatric intensive care unit (PICU) and recalibrate PELOD-2 in a Portuguese population. To achieve the previous goal, a prospective cohort study to evaluate score performance (standardized mortality ratio, discrimination, and calibration) for both models was performed. A total of 556 patients consecutively admitted to our PICU between January 2011 and December 2012 were included in the analysis. The median age was 65 months, with an interquartile range of 1 month to 17 years. The male-to-female ratio was 1.5. The median length of PICU stay was 3 days. The overall predicted number of deaths using PRISM III score was 30.8 patients whereas that by PELOD-2 was 22.1 patients. The observed mortality was 29 patients. The area under the receiver operating characteristics curve for the two models was 0.92 and 0.94, respectively. The Hosmer and Lemeshow goodness-of-fit test showed a good calibration only for PRISM III (PRISM III: χ (2) = 3.820, p = 0.282; PELOD-2: χ (2) = 9.576, p = 0.022). Both scores had good discrimination. PELOD-2 needs recalibration to be a better reliable prediction tool. • PRISM III (Pediatric Risk of Mortality III) and PELOD (Pediatric Logistic Organ Dysfunction) scores are frequently used to assess the performance of intensive care units and also for mortality prediction in the pediatric population. • Pediatric Logistic Organ Dysfunction 2 is the newer version of PELOD and has recently been validated with good discrimination and calibration. What is New: • In our population, both scores had good discrimination. • PELOD-2 needs recalibration to be a better reliable prediction tool.
NASA Astrophysics Data System (ADS)
Ash, William Mason, III
Total Internal Reflection Holographic Microscopy (TIRHM) combines near-field microscopy with digital holography to produce a new form of near-field phase microscopy. Using a prism in TIR as a near-field imager, the presence of microscopic organisms, cell-substrate interfaces, and adhesions, causes relative refractive index (RRI) and frustrated TIR (f-TIR) to modulate the object beam's evanescent wave phase front. Quantitative phase images of test specimens such as Amoeba proteus, Dictyostelium Discoideum and cells such as SKOV-3 ovarian cancer and 3T3 fibroblasts are produced without the need to introduce stains or fluorophores. The angular spectrum method of digital holography to compensate for tilt anamorphism due to the inclined TIR plane is also discussed. The results of this work conclusively demonstrate, for the first time, the integration of near-field microscopy with digital holography. The cellular images presented show a correlation between the physical extent of the Amoeba proteus plasma membrane and the adhesions that are quantitatively profiled by phase cross-sectioning of the holographic images obtained by digital holography. With its ability to quantitatively characterise cellular adhesion and motility, it is anticipated that TIRHM can be a tool for characterizing and combating cancer metastasis, as well as improving our understanding of morphogenesis and embryogenesis itself.
Chen, Zhijie; Weseliński, Łukasz J; Adil, Karim; Belmabkhout, Youssef; Shkurenko, Aleksander; Jiang, Hao; Bhatt, Prashant M; Guillerm, Vincent; Dauzon, Emilie; Xue, Dong-Xu; O'Keeffe, Michael; Eddaoudi, Mohamed
2017-03-01
Highly connected and edge-transitive nets are of prime importance in crystal chemistry and are regarded as ideal blueprints for the rational design and construction of metal-organic frameworks (MOFs). We report the design and synthesis of highly connected MOFs based on reticulation of the sole two edge-transitive nets with a vertex figure as double six-membered-ring (d6R) building unit, namely the (4,12)-coordinated shp net (square and hexagonal-prism) and the (6,12)-coordinated alb net (aluminum diboride, hexagonal-prism and trigonal-prism). Decidedly, the combination of our recently isolated 12-connected (12-c) rare-earth (RE) nonanuclear [RE 9 (μ 3 -OH) 12 (μ 3 -O) 2 (O 2 C-) 12 ] carboxylate-based cluster, points of extension matching the 12 vertices of hexagonal-prism d6R, with 4-connected (4-c) square porphyrinic tetracarboxylate ligand led to the formation of the targeted RE-shp-MOF. This is the first time that RE-MOFs based on 12-c molecular building blocks (MBBs), d6R building units, have been deliberately targeted and successfully isolated, paving the way for the long-awaited (6,12)-c MOF with alb topology. Indeed, combination of a custom-designed hexacarboxylate ligand with RE salts led to the formation of the first related alb-MOF, RE-alb-MOF. Intuitively, we successfully transplanted the alb topology to another chemical system and constructed the first indium-based alb-MOF, In-alb-MOF, by employing trinuclear [In 3 (μ 3 -O)(O 2 C-) 6 ] as the requisite 6-connected trigonal-prism and purposely made a dodecacarboxylate ligand as a compatible 12-c MBB. Prominently, the dodecacarboxylate ligand was employed to transplant shp topology into copper-based MOFs by employing the copper paddlewheel [Cu 2 (O 2 C-) 4 ] as the complementary square building unit, affording the first Cu-shp-MOF. We revealed that highly connected edge-transitive nets such shp and alb are ideal for topological transplantation and deliberate construction of related MOFs based on minimal edge-transitive nets.
NASA Astrophysics Data System (ADS)
Kaspar, Sebastian; Rattunde, Marcel; Töpper, Tino; Schwarz, Ulrich T.; Manz, Christian; Köhler, Klaus; Wagner, Joachim
2012-10-01
A 2 μm electro-optically cavity-dumped semiconductor disk laser (SDL) with a pulse full width at half maximum of 3 ns, a pulse peak power of 30 W, and repetition rates adjustable between 87 kHz and 1 MHz is reported. For ns-pulse cavity dumping the SDL was set up with a 35-cm long cavity into which an intra-cavity Brewster-angled polarizer prism and a Pockels cell for rotation of the linear polarization were inserted. By means of internal total reflection in the birefringent polarizer, pulses are coupled out of the cavity sideways. This variant of ns-pulse 2-μm SDL is well suited for applications such as high-precision light detection and ranging or ns-pulse laser materials processing after further power amplification.
Panico, Francesco; Sagliano, Laura; Grossi, Dario; Trojano, Luigi
2016-06-01
The aim of this study is to clarify the specific role of the cerebellum during prism adaptation procedure (PAP), considering its involvement in early prism exposure (i.e., in the recalibration process) and in post-exposure phase (i.e., in the after-effect, related to spatial realignment). For this purpose we interfered with cerebellar activity by means of cathodal transcranial direct current stimulation (tDCS), while young healthy individuals were asked to perform a pointing task on a touch screen before, during and after wearing base-left prism glasses. The distance from the target dot in each trial (in terms of pixels) on horizontal and vertical axes was recorded and served as an index of accuracy. Results on horizontal axis, that was shifted by prism glasses, revealed that participants who received cathodal stimulation showed increased rightward deviation from the actual position of the target while wearing prisms and a larger leftward deviation from the target after prisms removal. Results on vertical axis, in which no shift was induced, revealed a general trend in the two groups to improve accuracy through the different phases of the task, and a trend, more visible in cathodal stimulated participants, to worsen accuracy from the first to the last movements in each phase. Data on horizontal axis allow to confirm that the cerebellum is involved in all stages of PAP, contributing to early strategic recalibration process, as well as to spatial realignment. On vertical axis, the improving performance across the different stages of the task and the worsening accuracy within each task phase can be ascribed, respectively, to a learning process and to the task-related fatigue. Copyright © 2016 Elsevier Inc. All rights reserved.
1-D ELECTRO-OPTIC BEAM STEERING DEVICE
Wang, Wei-Chih; Tsui, Chi Leung
2011-01-01
In this paper, we present the design and fabrication of a 1D beam steering device based on planar electro-optic thermal-plastic prisms and a collimator lens array. With the elimination of moving parts, the proposed device is able to overcome the mechanical limitations of present scanning devices, such as fatigue and low operating frequency, while maintaining a small system footprint (~0.5mm×0.5mm). From experimental data, our prototype device is able to achieve a maximum deflection angle of 5.6° for a single stage prism design and 29.2° for a cascaded three prisms stage design. The lens array shows a 4µm collimated beam diameter. PMID:22199458
Watching Nanoscale Self-Assembly Kinetics of Gold Prisms in Liquids
NASA Astrophysics Data System (ADS)
Kim, Juyeong; Ou, Zihao; Jones, Matthew R.; Chen, Qian
We use liquid-phase transmission electron microscopy to watch self-assembly of gold triangular prisms into polymer-like structures. The in situ dynamics monitoring enabled by liquid-phase transmission electron microscopy, single nanoparticle tracking, and the marked conceptual similarity between molecular reactions and nanoparticle self-assembly combined elucidate the following mechanistic understanding: a step-growth polymerization based assembly statistics, kinetic pathways sampling particle curvature dependent energy minima and their interconversions, and directed assembly into polymorphs (linear or cyclic chains) through in situ modulation of the prism bonding geometry. Our study bridges the constituent kinetics on the molecular and nanoparticle length scales, which enriches the design rules in directed self-assembly of anisotropic nanoparticles.
NASA Astrophysics Data System (ADS)
Cui, Xiangyang; Li, She; Feng, Hui; Li, Guangyao
2017-05-01
In this paper, a novel triangular prism solid and shell interactive mapping element is proposed to solve the coupled magnetic-mechanical formulation in electromagnetic sheet metal forming process. A linear six-node "Triprism" element is firstly proposed for transient eddy current analysis in electromagnetic field. In present "Triprism" element, shape functions are given explicitly, and a cell-wise gradient smoothing operation is used to obtain the gradient matrices without evaluating derivatives of shape functions. In mechanical field analysis, a shear locking free triangular shell element is employed in internal force computation, and a data mapping method is developed to transfer the Lorentz force on solid into the external forces suffered by shell structure for dynamic elasto-plasticity deformation analysis. Based on the deformed triangular shell structure, a "Triprism" element generation rule is established for updated electromagnetic analysis, which means inter-transformation of meshes between the coupled fields can be performed automatically. In addition, the dynamic moving mesh is adopted for air mesh updating based on the deformation of sheet metal. A benchmark problem is carried out for confirming the accuracy of the proposed "Triprism" element in predicting flux density in electromagnetic field. Solutions of several EMF problems obtained by present work are compared with experiment results and those of traditional method, which are showing excellent performances of present interactive mapping element.
Contamination of disposable tonometer prisms during tonometry.
Rajak, S N; Paul, J; Sharma, V; Vickers, S
2006-03-01
Due to the theoretical possibility of prion transmission in applanation tonometry, many ophthalmological units in the United Kingdom now use disposable tonometer prisms. We have investigated the potential for bacterial and viral transmission from the health practitioner to the patient via disposable prisms. All staff who perform applanation tonometry at the Sussex Eye Hospital (SEH) received a questionnaire to evaluate if the applanating face of the prism is touched during tonometry and the ease of use of the disposable prism compared to the reusable prisms that were previously used. We then cultured prisms handled by a random sample of staff members for common bacteria. Finally, we constructed a model to investigate the possibility of interpatient adenoviral transmission via disposable tonometer prisms. The questionnaire revealed that almost 50% of the staff admit to touching the applanating face of the tonometer prism prior to applanation. Cultures of the prisms grew a range of bacteria including Staphylococcus epidermidis, Staphylococcus aureus, and Bacillus species. The viral model suggested that adenovirus could be transmitted by applanation tonometry. The use of disposable prisms for applanation tonometry may reduce the risk of prion transmission but is not bacteriologically or virologically aseptic. This is a potential infection risk to patients.
Beyond dipolar regime in high-order plasmon mode bowtie antennas
NASA Astrophysics Data System (ADS)
Cuche, Aurélien; Viarbitskaya, Sviatlana; Kumar, Upkar; Sharma, Jadab; Arbouet, Arnaud; Girard, Christian; Dujardin, Erik
2017-03-01
Optical nanoantennas have shown their great potential for far-field to near-field coupling and for light confinement in subwavelength volumes. Here, we report on a multimodal configuration for bright and polarization-dependent bowtie antenna based on large and highly crystalline gold prisms. Each individual prism constituting an antenna arm sustains high order plasmon modes in the visible and near infrared range that allow for high field confinement and two-dimensional optical information propagation. We demonstrate by scanning two-photon luminescence (TPL) microscopy and numerical simulations based on the Green dyadic method that these bowtie antennas result in intense hot spots in different antenna locations as a function of the incident polarization. Finally, we quantify the local field enhancement above the antennas by computing the normalized total decay rate of a molecular system placed in the near field of the antenna gap as a function of the dipole orientation. We demonstrate the existence of a subtle relation between antenna geometry, polarization dependence and field enhancement. These new multimodal optical antennas are excellent far field to near field converter and they open the door for new strategies in the design of coplanar optical components for a wide range of applications including sensing, energy conversion or integrated information processing.
Yadav, Naveen K; Ciuffreda, Kenneth J
2014-01-01
To assess quantitatively the effect and relative contribution of binasal occlusion (BNO) and base-in prisms (BI) on visually-evoked potential (VEP) responsivity in persons with mild traumatic brain injury (mTBI) and the symptom of visual motion sensitivity (VMS), as well as in visually-normal (VN) individuals. Subjects were comprised of 20 VN adults and 15 adults with mTBI and VMS. There were four test conditions: (1) conventional pattern VEP, which served as the baseline comparison condition; (2) VEP with BNO alone; (3) VEP with 2 pd BI prisms before each eye; and (4) VEP with the above BNO and BI prism combination. In mTBI, the mean VEP amplitude increased significantly in nearly all subjects (∼90%) with BNO alone. In contrast, in VN, it decreased significantly with BNO alone in all subjects (100%), as compared to the other test conditions. These objective findings were consistent with improvements in visual impressions and sensorimotor tasks in the group with mTBI. Latency remained within normal limits under all test conditions in both groups. Only the BNO condition demonstrated significant, but opposite and consistent, directional effects on the VEP amplitude in both groups. The BNO-VEP test condition may be used clinically for the objectively-based, differential diagnosis of persons suspected of having mTBI and VMS from the VNs.
Infrared zone-scanning system.
Belousov, Aleksandr; Popov, Gennady
2006-03-20
Challenges encountered in designing an infrared viewing optical system that uses a small linear detector array based on a zone-scanning approach are discussed. Scanning is performed by a rotating refractive polygon prism with tilted facets, which, along with high-speed line scanning, makes the scanning gear as simple as possible. A method of calculation of a practical optical system to compensate for aberrations during prism rotation is described.
Assessing causal mechanistic interactions: a peril ratio index of synergy based on multiplicativity.
Lee, Wen-Chung
2013-01-01
The assessments of interactions in epidemiology have traditionally been based on risk-ratio, odds-ratio or rate-ratio multiplicativity. However, many epidemiologists fail to recognize that this is mainly for statistical conveniences and often will misinterpret a statistically significant interaction as a genuine mechanistic interaction. The author adopts an alternative metric system for risk, the 'peril'. A peril is an exponentiated cumulative rate, or simply, the inverse of a survival (risk complement) or one plus an odds. The author proposes a new index based on multiplicativity of peril ratios, the 'peril ratio index of synergy based on multiplicativity' (PRISM). Under the assumption of no redundancy, PRISM can be used to assess synergisms in sufficient cause sense, i.e., causal co-actions or causal mechanistic interactions. It has a less stringent threshold to detect a synergy as compared to a previous index of 'relative excess risk due to interaction'. Using the new PRISM criterion, many situations in which there is not evidence of interaction judged by the traditional indices are in fact corresponding to bona fide positive or negative synergisms.
Assessing Causal Mechanistic Interactions: A Peril Ratio Index of Synergy Based on Multiplicativity
Lee, Wen-Chung
2013-01-01
The assessments of interactions in epidemiology have traditionally been based on risk-ratio, odds-ratio or rate-ratio multiplicativity. However, many epidemiologists fail to recognize that this is mainly for statistical conveniences and often will misinterpret a statistically significant interaction as a genuine mechanistic interaction. The author adopts an alternative metric system for risk, the ‘peril’. A peril is an exponentiated cumulative rate, or simply, the inverse of a survival (risk complement) or one plus an odds. The author proposes a new index based on multiplicativity of peril ratios, the ‘peril ratio index of synergy based on multiplicativity’ (PRISM). Under the assumption of no redundancy, PRISM can be used to assess synergisms in sufficient cause sense, i.e., causal co-actions or causal mechanistic interactions. It has a less stringent threshold to detect a synergy as compared to a previous index of ‘relative excess risk due to interaction’. Using the new PRISM criterion, many situations in which there is not evidence of interaction judged by the traditional indices are in fact corresponding to bona fide positive or negative synergisms. PMID:23826299
Enhanced sensitivity for optical loss measurement in planar thin-films (Conference Presentation)
NASA Astrophysics Data System (ADS)
Yuan, Hua-Kang
2016-09-01
An organic-inorganic hybrid material benefits from processing advantages of organics and high refractive indices of inorganics. We focus on a titanium oxide hydrate system combined with common bulk polymers. In particular, we target thin-film structures of a few microns in thickness. Traditional Beer-Lambert approaches for measuring optical losses can only provide an upper limit estimate. This sensitivity is highly limited when considering the low-losses required for mid-range optical applications, on the order of 0.1 cm-1. For intensity based measurements, improving the sensitivity requires an increase in the optical path length. Instead, a new sensitive technique suitable for simple planar thin films is required. A number of systems were modelled to measure optical losses in films of 1 micron thick. The presented techniques utilise evanescent waves and total internal reflection to increase optical path length through the material. It was found that a new way of using prism coupling provides the greatest improvement in sensitivity. In keeping the requirements on the material simple, this method for measuring loss is well suited to any future developments of new materials in thin-film structures.
Houston, Kevin E.; Peli, Eli; Goldstein, Robert B.; Bowers, Alex R.
2018-01-01
Purpose Drivers with homonymous hemianopia (HH) were previously found to have impaired detection of blind-side hazards, yet in many jurisdictions they may obtain a license. We evaluated whether oblique 57Δ peripheral prisms (p-prisms) and perceptual-motor training improved blind-side detection rates. Methods Patients with HH (n = 11) wore p-prisms for 2 weeks and then received perceptual-motor training (six visits) detecting and touching stimuli in the prism-expanded vision. In a driving simulator, patients drove and pressed the horn upon detection of pedestrians who ran toward the roadway (26 from each side): (1) without p-prisms at baseline; (2) with p-prisms after 2 weeks acclimation but before training; (3) with p-prisms after training; and (4) 3 months later. Results P-prisms improved blind-side detection from 42% to 56%, which further improved after training to 72% (all P < 0.001). Blind-side timely responses (adequate time to have stopped) improved from 31% without to 44% with p-prisms (P < 0.001) and further improved with training to 55% (P = 0.02). At the 3-month follow-up, improvements from training were maintained for detection (65%; P = 0.02) but not timely responses (P = 0.725). There was wide between-subject variability in baseline detection performance and response to p-prisms. There were no negative effects of p-prisms on vehicle control or seeing-side performance. Conclusions P-prisms improved detection with no negative effects, and training may provide additional benefit. Translational Relevance In jurisdictions where people with HH are legally driving, these data aid in clinical decision making by providing evidence that p-prisms improve performance without negative effects. PMID:29359111
Latysh, Natalie E.; Wetherbee, Gregory Alan
2012-01-01
High-elevation regions in the United States lack detailed atmospheric wet-deposition data. The National Atmospheric Deposition Program/National Trends Network (NADP/NTN) measures and reports precipitation amounts and chemical constituent concentration and deposition data for the United States on annual isopleth maps using inverse distance weighted (IDW) interpolation methods. This interpolation for unsampled areas does not account for topographic influences. Therefore, NADP/NTN isopleth maps lack detail and potentially underestimate wet deposition in high-elevation regions. The NADP/NTN wet-deposition maps may be improved using precipitation grids generated by other networks. The Parameter-elevation Regressions on Independent Slopes Model (PRISM) produces digital grids of precipitation estimates from many precipitation-monitoring networks and incorporates influences of topographical and geographical features. Because NADP/NTN ion concentrations do not vary with elevation as much as precipitation depths, PRISM is used with unadjusted NADP/NTN data in this paper to calculate ion wet deposition in complex terrain to yield more accurate and detailed isopleth deposition maps in complex terrain. PRISM precipitation estimates generally exceed NADP/NTN precipitation estimates for coastal and mountainous regions in the western United States. NADP/NTN precipitation estimates generally exceed PRISM precipitation estimates for leeward mountainous regions in Washington, Oregon, and Nevada, where abrupt changes in precipitation depths induced by topography are not depicted by IDW interpolation. PRISM-based deposition estimates for nitrate can exceed NADP/NTN estimates by more than 100% for mountainous regions in the western United States.
Latysh, Natalie E; Wetherbee, Gregory Alan
2012-01-01
High-elevation regions in the United States lack detailed atmospheric wet-deposition data. The National Atmospheric Deposition Program/National Trends Network (NADP/NTN) measures and reports precipitation amounts and chemical constituent concentration and deposition data for the United States on annual isopleth maps using inverse distance weighted (IDW) interpolation methods. This interpolation for unsampled areas does not account for topographic influences. Therefore, NADP/NTN isopleth maps lack detail and potentially underestimate wet deposition in high-elevation regions. The NADP/NTN wet-deposition maps may be improved using precipitation grids generated by other networks. The Parameter-elevation Regressions on Independent Slopes Model (PRISM) produces digital grids of precipitation estimates from many precipitation-monitoring networks and incorporates influences of topographical and geographical features. Because NADP/NTN ion concentrations do not vary with elevation as much as precipitation depths, PRISM is used with unadjusted NADP/NTN data in this paper to calculate ion wet deposition in complex terrain to yield more accurate and detailed isopleth deposition maps in complex terrain. PRISM precipitation estimates generally exceed NADP/NTN precipitation estimates for coastal and mountainous regions in the western United States. NADP/NTN precipitation estimates generally exceed PRISM precipitation estimates for leeward mountainous regions in Washington, Oregon, and Nevada, where abrupt changes in precipitation depths induced by topography are not depicted by IDW interpolation. PRISM-based deposition estimates for nitrate can exceed NADP/NTN estimates by more than 100% for mountainous regions in the western United States.
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
This dataset represents climate observations throughout the years 2008-09 within individual local NHDPlusV2 catchments and upstream, contributing watersheds based on the Composite Topographic Index (See Supplementary Info for Glossary of Terms). PRISM is a set of monthly, yearly, and single-event gridded data products of mean temperature and precipitation, max/min temperatures, and dewpoints, primarily for the United States. In-situ point measurements are ingested into the PRISM (Parameter elevation Regression on Independent Slopes Model) statistical mapping system. The PRISM products use a weighted regression scheme to account for complex climate regimes associated with orography, rain shadows, temperature inversions, slope aspect, coastal proximity, and other factors. (see Data Sources for links to NHDPlusV2 data and USGS Data) These data were summarized to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).
Kuzu, Guray; Keskin, Ozlem; Nussinov, Ruth; Gursoy, Attila
2016-10-01
The structures of protein assemblies are important for elucidating cellular processes at the molecular level. Three-dimensional electron microscopy (3DEM) is a powerful method to identify the structures of assemblies, especially those that are challenging to study by crystallography. Here, a new approach, PRISM-EM, is reported to computationally generate plausible structural models using a procedure that combines crystallographic structures and density maps obtained from 3DEM. The predictions are validated against seven available structurally different crystallographic complexes. The models display mean deviations in the backbone of <5 Å. PRISM-EM was further tested on different benchmark sets; the accuracy was evaluated with respect to the structure of the complex, and the correlation with EM density maps and interface predictions were evaluated and compared with those obtained using other methods. PRISM-EM was then used to predict the structure of the ternary complex of the HIV-1 envelope glycoprotein trimer, the ligand CD4 and the neutralizing protein m36.
Migration monitoring in shorebirds and landbirds: commonalities and differences
Susan K. Skagen; Jonathan Bart
2005-01-01
Several aspects of a developing program to monitor shorebirds in the western hemisphere are pertinent to migration monitoring of landbirds. Goals of the Program for Regional and International Shorebird Monitoring (PRISM) include estimating population size and population trends of 74 species, sub-species and distinct populations of North American shorebirds, monitoring...
Methods for shorebird surveys in the Arctic
Jonathan Bart; Susan L. Earnst
2005-01-01
A substantial effort is being made to develop a longterm monitoring program for shorebirds in North American (Brown et al. 2000, Donaldson et al. 2001, Bart et al. this volume). The current program, PRISM (Program for Regional and International Shorebird Monitoring), has four segments: arctic and boreal breeding surveys, temperate breeding surveys, temperate non-...
Seeing Education through the Prism of PISA
ERIC Educational Resources Information Center
Schleicher, Andreas
2017-01-01
International comparisons are never easy and they are not perfect. But PISA shows what is possible in education and it helps countries to see themselves in the mirror of student performance and educational possibilities in other countries. This article summarises key policy insights from PISA. It highlights how excellence and improving equity need…
Seeing the United States Education System through the Prism of International Comparisons
ERIC Educational Resources Information Center
Schleicher, Andreas
2009-01-01
In this globalized world, individuals and countries that invest heavily in education increasingly benefit socially and economically from that choice. Among the 30 Organization for Economic Cooperation and Development (OECD) countries with the largest expansion of college education over the last decades, most still see rising earnings differentials…
Monitoring the shorebirds of North America: Towards a unified approach
Skagen, S.K.; Bart, J.; Andres, B.; Brown, S.; Donaldson, G.; Harrington, B.; Johnston, V.; Jones, S.L.; Morrison, R.I.G.
2003-01-01
The Program for Regional and International Shorebird Monitoring (PRISM) has recently developed a single blueprint for monitoring shorebirds in Canada and the United States in response to needs identified by recent shorebird conservation plans. The goals of PRISM are to: (1) estimate the size of breeding populations of 74 shorebird taxa in North America; (2) describe the distribution, abundance, and habitat relationships for these taxa; (3) monitor trends in shorebird population size; (4) monitor shorebird numbers at stopover locations, and; (5) assist local managers in meeting their shorebird conservation goals. The initial focus has been on developing methods to estimate trends in population size. A three-part approach for estimating trends includes: (1) breeding surveys in arctic, boreal, and temperate regions, (2) migration surveys, and (3) wintering surveys.
Apfelbaum, Henry L.; Ross, Nicole C.; Bowers, Alex R.; Peli, Eli
2013-01-01
Purpose: While prisms are commonly prescribed for homonymous hemianopia to extend or expand the visual field, they cause potentially troubling visual side effects, including nonveridical location of perceived images, diplopia, and visual confusion. In addition, the field behind a prism at its apex is lost to an apical scotoma equal in magnitude to the amount of prism shift. The perceptual consequences of apical scotomas and the other effects of various designs were examined to consider parameters and designs that can mitigate the impact of these effects. Methods: Various configurations of sector and peripheral prisms were analyzed, in various directions of gaze, and their visual effects were illustrated using simulated perimetry. A novel “percept” diagram was developed that yielded insights into the patient's view through the prisms. The predictions were verified perimetrically with patients. Results: The diagrams distinguish between potentially beneficial field expansion via visual confusion and the pericentrally disturbing and useless effect of diplopia, and their relationship to prism power and gaze direction. They also illustrate the nonexpanding substitution of field segments of some popular prism designs. Conclusions: Yoked sector prisms have no effect at primary gaze or when gaze is directed toward the seeing hemifield, and they introduce pericentral field loss when gaze is shifted into them. When fitted unilaterally, sector prisms also have an effect only when the gaze is directed into the prism and may cause a pericentral scotoma and/or central diplopia. Peripheral prisms are effective at essentially all gaze angles. Since gaze is not directed into them, they avoid problematic pericentral effects. We derive useful recommendations for prism power and position parameters, including novel ways of fitting prisms asymmetrically. Translational Relevance: Clinicians will find these novel diagrams, diagramming techniques, and analyses valuable when prescribing prismatic aids for hemianopia and when designing new prism devices for patients with various types of field loss. PMID:24049719
Peripheral prism glasses: effects of moving and stationary backgrounds.
Shen, Jieming; Peli, Eli; Bowers, Alex R
2015-04-01
Unilateral peripheral prisms for homonymous hemianopia (HH) expand the visual field through peripheral binocular visual confusion, a stimulus for binocular rivalry that could lead to reduced predominance and partial suppression of the prism image, thereby limiting device functionality. Using natural-scene images and motion videos, we evaluated whether detection was reduced in binocular compared with monocular viewing. Detection rates of nine participants with HH or quadranopia and normal binocularity wearing peripheral prisms were determined for static checkerboard perimetry targets briefly presented in the prism expansion area and the seeing hemifield. Perimetry was conducted under monocular and binocular viewing with targets presented over videos of real-world driving scenes and still frame images derived from those videos. With unilateral prisms, detection rates in the prism expansion area were significantly lower in binocular than in monocular (prism eye) viewing on the motion background (medians, 13 and 58%, respectively, p = 0.008) but not the still frame background (medians, 63 and 68%, p = 0.123). When the stimulus for binocular rivalry was reduced by fitting prisms bilaterally in one HH and one normally sighted subject with simulated HH, prism-area detection rates on the motion background were not significantly different (p > 0.6) in binocular and monocular viewing. Conflicting binocular motion appears to be a stimulus for reduced predominance of the prism image in binocular viewing when using unilateral peripheral prisms. However, the effect was only found for relatively small targets. Further testing is needed to determine the extent to which this phenomenon might affect the functionality of unilateral peripheral prisms in more real-world situations.
Peripheral Prism Glasses: Effects of Moving and Stationary Backgrounds
Shen, Jieming; Peli, Eli; Bowers, Alex R.
2015-01-01
Purpose Unilateral peripheral prisms for homonymous hemianopia (HH) expand the visual field through peripheral binocular visual confusion, a stimulus for binocular rivalry that could lead to reduced predominance (partial local suppression) of the prism image and limit device functionality. Using natural-scene images and motion videos, we evaluated whether detection was reduced in binocular compared to monocular viewing. Methods Detection rates of nine participants with HH or quadranopia and normal binocularity wearing peripheral prisms were determined for static checkerboard perimetry targets briefly presented in the prism expansion area and the seeing hemifield. Perimetry was conducted under monocular and binocular viewing with targets presented over videos of real-world driving scenes and still frame images derived from those videos. Results With unilateral prisms, detection rates in the prism expansion area were significantly lower in binocular than monocular (prism eye) viewing on the motion background (medians 13% and 58%, respectively, p = 0.008), but not the still frame background (63% and 68%, p = 0.123). When the stimulus for binocular rivalry was reduced by fitting prisms bilaterally in 1 HH and 1 normally-sighted subject with simulated HH, prism-area detection rates on the motion background were not significantly different (p > 0.6) in binocular and monocular viewing. Conclusions Conflicting binocular motion appears to be a stimulus for reduced predominance of the prism image in binocular viewing when using unilateral peripheral prisms. However, the effect was only found for relatively small targets. Further testing is needed to determine the extent to which this phenomenon might affect the functionality of unilateral peripheral prisms in more real-world situations. PMID:25785533
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyamekye, Charles K. A.; Weibel, Stephen C.; Bobbitt, Jonathan M.
Directional-surface-plasmon-coupled Raman scattering (directional RS) has the combined benefits of surface plasmon resonance and Raman spectroscopy, and provides the ability to measure adsorption and monolayer-sensitive chemical information. Directional RS is performed by optically coupling a 50-nm gold film to a Weierstrass prism in the Kretschmann configuration and scanning the angle of the incident laser under total internal reflection. The collected parameters on the prism side of the interface include a full surface-plasmon-polariton cone and the full Raman signal radiating from the cone as a function of incident angle. An instrument for performing directional RS and a quantitative study of themore » instrumental parameters are herein reported. To test the sensitivity and quantify the instrument parameters, self-assembled monolayers and 10 to 100-nm polymer films are studied. The signals are found to be well-modeled by two calculated angle-dependent parameters: three-dimensional finite-difference time-domain calculations of the electric field generated in the sample layer and projected to the far-field, and Fresnel calculations of the reflected light intensity. This is the first report of the quantitative study of the full surface-plasmon-polariton cone intensity, cone diameter, and directional Raman signal as a function of incident angle. We propose that directional RS is a viable alternative to surface plasmon resonance when added chemical information is beneficial.« less
Nyamekye, Charles K. A.; Weibel, Stephen C.; Bobbitt, Jonathan M.; ...
2017-09-15
Directional-surface-plasmon-coupled Raman scattering (directional RS) has the combined benefits of surface plasmon resonance and Raman spectroscopy, and provides the ability to measure adsorption and monolayer-sensitive chemical information. Directional RS is performed by optically coupling a 50-nm gold film to a Weierstrass prism in the Kretschmann configuration and scanning the angle of the incident laser under total internal reflection. The collected parameters on the prism side of the interface include a full surface-plasmon-polariton cone and the full Raman signal radiating from the cone as a function of incident angle. An instrument for performing directional RS and a quantitative study of themore » instrumental parameters are herein reported. To test the sensitivity and quantify the instrument parameters, self-assembled monolayers and 10 to 100-nm polymer films are studied. The signals are found to be well-modeled by two calculated angle-dependent parameters: three-dimensional finite-difference time-domain calculations of the electric field generated in the sample layer and projected to the far-field, and Fresnel calculations of the reflected light intensity. This is the first report of the quantitative study of the full surface-plasmon-polariton cone intensity, cone diameter, and directional Raman signal as a function of incident angle. We propose that directional RS is a viable alternative to surface plasmon resonance when added chemical information is beneficial.« less
[Research on improving spectrum resolution of optimized Wollaston prism array].
Zhang, Peng; Wang, Jian-Rong; Zhang, Guo-Chen; Hou, Wen
2011-11-01
In order to not affect the image quality of interference fringes on the basis of the structure by increasing the structure angle of Wollaston prism to improve spectrum resolution, the authors optimized the structure of Wollaston prism. Calculating the function of the splitting angle and the structure angle, analysis indicated that taking the isosceles triangle prism with the same nature of the second wedge-shaped prism after the Wollaston prism, which makes the o and e light parallel to the optical axis, and alpha=0 degrees, the imaging interference fringes are no longer affected by changes in the splitting angle. Several optimized Wollaston prisms were made as an array to improve the spectral resolution. Experiments used traditional and optimized Wollaston prism array to detect the spectrum of the 980 nm laser. Experimental data showed that using optimized Wollaston prism array gets a clearer contrast of interference fringes, and the spectral data with Fourier transform are more accurate with DSP.
NASA Astrophysics Data System (ADS)
Leviton, Douglas B.; Miller, Kevin H.; Quijada, Manuel A.; Groff, Tyler D.
2015-09-01
Using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have made the first cryogenic measurements of absolute refractive index for Ohara L-BBH2 glass to enable the design of a prism for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) at the Subaru telescope. L-BBH2 is employed in CHARIS's prism design for improving the spectrograph's dispersion uniformity. Index measurements were made at temperatures from 110 to 305 K at wavelengths from 0.46 to 3.16 μm. We report absolute refractive index (n), dispersion (dn/dλ), and thermo-optic coefficient (dn/dT) for this material along with estimated single measurement uncertainties as a function of wavelength and temperature. We provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures within applicable ranges. This paper also speaks of the challenges in measuring index for a material which is not available in sufficient thickness to fabricate a typical prism for measurement in CHARMS, the tailoring of the index prism design that allowed these index measurements to be made, and the remarkable results obtained from that prism for this practical infrared material.
NASA Technical Reports Server (NTRS)
Leviton, Douglas B.; Miller, Kevin H.; Quijada, Manuel A.; Groff, Tyler D.
2015-01-01
Using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have made the first cryogenic measurements of absolute refractive index for Ohara L-BBH2 glass to enable the design of a prism for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) at the Subaru telescope. L-BBH2 is employed in CHARIS's prism design for improving the spectrograph's dispersion uniformity. Index measurements were made at temperatures from 110 to 305 K at wavelengths from 0.46 to 3.16 micron. We report absolute refractive index (n), dispersion (dn/d(lambda), and thermo-optic coefficient (dn/dT) for this material along with estimated single measurement uncertainties as a function of wavelength and temperature. We provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures within applicable ranges. This paper also speaks of the challenges in measuring index for a material which is not available in sufficient thickness to fabricate a typical prism for measurement in CHARMS, the tailoring of the index prism design that allowed these index measurements to be made, and the remarkable results obtained from that prism for this practical infrared material.
Zhou, Jie; Du, Xuewen; Xu, Bing
2015-01-01
Formed by non-covalent interactions and not defined at genetic level, the assemblies of small molecules in biology are complicated and less explored. A common morphology of the supramolecular assemblies of small molecules is nanofibrils, which coincidentally resembles the nanofibrils formed by proteins such as prions. So these supramolecular assemblies are termed as prion-like nanofibrils of small molecules (PriSM). Emerging evidence from several unrelated fields over the past decade implies the significance of PriSM in biology and medicine. This perspective aims to highlight some recent advances of the research on PriSM. This paper starts with description of the intriguing similarities between PriSM and prions, discusses the paradoxical features of PriSM, introduces the methods for elucidating the biological functions of PriSM, illustrates several examples of beneficial aspects of PriSM, and finishes with the promises and current challenges in the research of PriSM. We anticipate that the research of PriSM will contribute to the fundamental understanding at the intersection of supramolecular chemistry and cell biology and ultimately lead to a new paradigm of molecular (or supramolecular) therapeutics for biomedicine.
Zhou, Jie; Du, Xuewen; Xu, Bing
2015-01-01
Abstract Formed by non-covalent interactions and not defined at genetic level, the assemblies of small molecules in biology are complicated and less explored. A common morphology of the supramolecular assemblies of small molecules is nanofibrils, which coincidentally resembles the nanofibrils formed by proteins such as prions. So these supramolecular assemblies are termed as prion-like nanofibrils of small molecules (PriSM). Emerging evidence from several unrelated fields over the past decade implies the significance of PriSM in biology and medicine. This perspective aims to highlight some recent advances of the research on PriSM. This paper starts with description of the intriguing similarities between PriSM and prions, discusses the paradoxical features of PriSM, introduces the methods for elucidating the biological functions of PriSM, illustrates several examples of beneficial aspects of PriSM, and finishes with the promises and current challenges in the research of PriSM. We anticipate that the research of PriSM will contribute to the fundamental understanding at the intersection of supramolecular chemistry and cell biology and ultimately lead to a new paradigm of molecular (or supramolecular) therapeutics for biomedicine. PMID:25738892
Prism adaptation speeds reach initiation in the direction of the prism after-effect.
Striemer, Christopher L; Borza, Carley A
2017-10-01
Damage to the temporal-parietal cortex in the right hemisphere often leads to spatial neglect-a disorder in which patients are unable to attend to sensory input from their contralesional (left) side. Neglect has been associated with both attentional and premotor deficits. That is, in addition to having difficulty with attending to the left side, patients are often slower to initiate leftward vs. rightward movements (i.e., directional hypokinesia). Previous research has indicated that a brief period of adaptation to rightward shifting prisms can reduce symptoms of neglect by adjusting the patient's movements leftward, toward the neglected field. Although prism adaptation has been shown to reduce spatial attention deficits in patients with neglect, very little work has examined the effects of prisms on premotor symptoms. In the current study, we examined this in healthy individuals using leftward shifting prisms to induce a rightward shift in the egocentric reference frame, similar to neglect patients prior to prism adaptation. Specifically, we examined the speed with which healthy participants initiated leftward and rightward reaches (without visual feedback) prior to and following adaptation to either 17° leftward (n = 16) or 17° rightward (n = 15) shifting prisms. Our results indicated that, following adaptation, participants were significantly faster to initiate reaches towards targets located in the direction opposite the prism shift. That is, participants were faster to initiate reaches to right targets following leftward prism adaptation and were faster to initiate reaches to left targets following rightward prism adaptation. Overall, these results are consistent with the idea that prism adaptation can influence the speed with which a reach can be initiated toward a target in the direction opposite the prism shift, possibly through altering activity in neural circuits involved in reach planning.
Mühleisen, Beda; Büchi, Stefan; Schmidhauser, Simone; Jenewein, Josef; French, Lars E; Hofbauer, Günther F L
2009-07-01
To validate the PRISM (Pictorial Representation of Illness and Self Measure) tool, a novel visual instrument, for the assessment of health-related quality of life in dermatological inpatients compared with the Dermatology Life Quality Index (DLQI) and the Skindex-29 questionnaires and to report qualitative information on PRISM. In an open longitudinal study, PRISM and Skindex-29 and DLQI questionnaires were completed and HRQOL measurements compared. Academic dermatological inpatient ward. The study population comprised 227 sequential dermatological inpatients on admission. Patients completed the PRISM tool and the Skindex-29 and DLQI questionnaires at admission and discharge. PRISM Self-Illness Separation (SIS) score; Skindex-29 and DLQI scores; and qualitative PRISM information by Mayring inductive qualitative context analysis. The PRISM scores correlated well with those from the Skindex-29 (rho = 0.426; P < .001) and DLQI (rho = 0.304; P < .001) questionnaires. Between PRISM and Skindex-29 scores, the highest correlations were for dermatitis (rho = 0.614) and leg ulcer (rho = 0.554), and between PRISM and DLQI scores, the highest correlations were for psoriasis (rho = 0.418) and tumor (rho = 0.399). The PRISM tool showed comparable or higher sensitivity than quality of life questionnaires to assess changes in the burden of suffering during hospitalization. Inductive qualitative context analysis revealed impairment of adjustment and self-image as major aspects. Patients overall expected symptomatic and functional improvement. In patients with psoriasis and leg ulcers, many expected no treatment benefit. The PRISM tool proved to be convenient and reliable for health-related quality of life assessment, applicable for a wide range of skin diseases, and correlated with DLQI and Skindex-29 scores. With the PRISM tool, free-text answers allow for the assessment of individual information and potentially customized therapeutic approaches.
COLD MAGICS - Continuous Local Deformation Monitoring of an Arctic Geodetic Fundamental Station
NASA Technical Reports Server (NTRS)
Haas, Ruediger; Bergstrand, Sten
2010-01-01
We describe the experience gained in a project to continuously monitor the local tie at the Geodetic Observatory Ny-Alesund. A PC-controlled robotic total station was used to monitor survey prisms that were attached to survey pillars of the local network and the monuments used for geodetic VLBI and GNSS measurements. The monitoring lasted for seven days and had a temporal resolution of six minutes. The raw angle and distance measurements show clear sinusoidal signatures with a daily period, most strongly for a four-day period with 24 hours of sunshine. The derived topocentric coordinates of the survey prisms attached to the GNSS monument and the VLBI radio telescope act as approximation for the local tie. We detect clear signatures at the mm-level. With the current approach we cannot distinguish between real motion of the prisms and potential thermal influences on the instrument used for the observations. However, the project shows that continuous local tie monitoring is feasible today and in the future can and should be used for all geodetic co-location stations.
He, Jintang; Schepmoes, Athena A.; Shi, Tujin; ...
2015-01-01
Background: The established methods for detecting prostate cancer (CaP) are based on tests using PSA (blood), PCA3 (urine), and AMACR (tissue) as biomarkers in patient samples. The demonstration of ERG oncoprotein overexpression due to gene fusion in CaP has thus provided ERG as an additional biomarker. Based on this, we hypothesized that ERG protein quantification methods can be of use in the diagnosis of prostate cancer. Methods: Therefore, an antibody-free assay for ERG3 protein detection was developed based on PRISM (high-pressure high-resolution separations with intelligent selection and multiplexing)-SRM (selected reaction monitoring) mass spectrometry. We utilized TMPRSS2-ERG positive VCaP and TMPRSS2-ERGmore » negative LNCaP cells to simulate three different sample types (cells, tissue, and post-DRE urine sediment). Results: Recombinant ERG3 protein spiked into LNCaP cell lysates could be detected at levels as low as 20 pg by PRISM-SRM analysis. The sensitivity of the PRISM-SRM assay was around approximately 10,000 VCaP cells in a mixed cell population model of VCaP and LNCaP cells. Interestingly, ERG protein could be detected in as few as 600 VCaP cells spiked into female urine. The sensitivity of the in-house enzyme-linked immunosorbent assay (ELISA) was similar to the PRISM-SRM assay, with detection of 30 pg of purified recombinant ERG3 protein and 10,000 VCaP cells. On the other hand, qRT-PCR exhibited a higher sensitivity, as TMPRSS2-ERG transcripts were detected in as few as 100 VCaP cells, in comparison to NanoString methodologies which detected ERG from 10,000 cells. Conclusions: Based on this data, we propose that the detection of both ERG transcriptional products with RNA-based assays, as well as protein products of ERG using PRISM-SRM assays, may be of clinical value in developing diagnostics and prognostics assays for prostate cancer given their sensitivity, specificity, and reproducibility.« less
Dynamic changes in brain activity during prism adaptation.
Luauté, Jacques; Schwartz, Sophie; Rossetti, Yves; Spiridon, Mona; Rode, Gilles; Boisson, Dominique; Vuilleumier, Patrik
2009-01-07
Prism adaptation does not only induce short-term sensorimotor plasticity, but also longer-term reorganization in the neural representation of space. We used event-related fMRI to study dynamic changes in brain activity during both early and prolonged exposure to visual prisms. Participants performed a pointing task before, during, and after prism exposure. Measures of trial-by-trial pointing errors and corrections allowed parametric analyses of brain activity as a function of performance. We show that during the earliest phase of prism exposure, anterior intraparietal sulcus was primarily implicated in error detection, whereas parieto-occipital sulcus was implicated in error correction. Cerebellum activity showed progressive increases during prism exposure, in accordance with a key role for spatial realignment. This time course further suggests that the cerebellum might promote neural changes in superior temporal cortex, which was selectively activated during the later phase of prism exposure and could mediate the effects of prism adaptation on cognitive spatial representations.
Students' ideas about prismatic images: teaching experiments for an image-based approach
NASA Astrophysics Data System (ADS)
Grusche, Sascha
2017-05-01
Prismatic refraction is a classic topic in science education. To investigate how undergraduate students think about prismatic dispersion, and to see how they change their thinking when observing dispersed images, five teaching experiments were done and analysed according to the Model of Educational Reconstruction. For projection through a prism, the students used a 'split image projection' conceptualisation. For the view through a prism, this conceptualisation was not fruitful. Based on the observed images, six of seven students changed to a 'diverted image projection' conceptualisation. From a comparison between students' and scientists' ideas, teaching implications are derived for an image-based approach.
Contributions of Arctic PRISM to monitoring western hemispheric shorebirds
Skagen, Susan K.; Smith, Paul A.; Andres, Brad A.; Donaldson, Garry; Brown, Stephen
2012-01-01
Long-term monitoring of populations is of paramount importance to understanding responses oforganisms to global environmental change and to evaluating whether conservation practices are yielding intended results through time (Wiens 2009). The population status of many shorebird species, the focus of this volume, remain poorly known. Long-distance migrant shorebirds have proven particularly difficult to monitor, in part because of their highly migratory nature and ranges that extend into highly inaccessible regions. As migrant shorebirds travel the length of the hemisphere, they congregate and disperse in ways that vary among species, locations, and years, presenting serious challenges to designing and implementing monitoring programs. Rigorous field and quantitative methods that estimate population size and monitor trends are vitally needed to direct and evaluate effective conservation measures. Many management efforts depend on unbiased population size estimates; for example, the shorebird conservation plans for both Canada and the United States seek to restore populations to levels calculated for the 1970s based on the best information available from existing surveys. Further, federal wildlife agencies within the United States and Canada have mandates to understand the state of their nations' resources under various conventions for the protection of migratory birds. Accurate estimates of population size are vital statistics for a variety of conservation activities, such as prioritizing species for conservation action and setting management targets. Areas of essential habitat, such as those designated under the Western Hemisphere Shorebird Reserve Network, the Important Bird Areas program of BirdLife International and the National Audubon Society, or Canada's National Wildlife Areas program, are all evaluated on the basis ofproportions of species' populations which they contain. The size, and trends in size, ofa species' population are considered key information for assessing its vulnerability and subsequent listing under the U.S. Endangered Species Act and the Canadian Species at Risk Act. To meet the need for information on population size and trends, shorebird biologists from Canada and the United States proposed a shared blueprint for shorebird monitoring across the Western Hemisphere in the late 1990s; this effort was undertaken in concert with the development of the Canadian and U.S. Shorebird Conservation Plans (Donaldson et al. 2000, Brown et aL 2001). Soon thereafter, partners in the monitoring effort adopted the name "Program for Regional and International Shorebird Monitoring" (PRISM). Among the primary objectives of PRISM were to estimate the population sizes and trends of breeding North American shorebirds and describe their distributions (Bart et al. 2002). PRISM members evaluated ongoing and potential monitoring approaches to address 74 taxa (including subspecies) and proposed a combination of arctic andboreal breeding surveys, temperate breeding and non-breeding surveys, and neotropical surveys.
A Pilot Study of Perceptual-Motor Training for Peripheral Prisms
Houston, Kevin E.; Bowers, Alex R.; Fu, Xianping; Liu, Rui; Goldstein, Robert B.; Churchill, Jeff; Wiegand, Jean-Paul; Soo, Tim; Tang, Qu; Peli, Eli
2016-01-01
Purpose Peripheral prisms (p-prisms) shift peripheral portions of the visual field of one eye, providing visual field expansion for patients with hemianopia. However, patients rarely show adaption to the shift, incorrectly localizing objects viewed within the p-prisms. A pilot evaluation of a novel computerized perceptual-motor training program aiming to promote p-prism adaption was conducted. Methods Thirteen patients with hemianopia fitted with 57Δ oblique p-prisms completed the training protocol. They attended six 1-hour visits reaching and touching peripheral checkerboard stimuli presented over videos of driving scenes while fixating a central target. Performance was measured at each visit and after 3 months. Results There was a significant reduction in touch error (P = 0.01) for p-prism zone stimuli from pretraining median of 16.6° (IQR 12.1°–19.6°) to 2.7° ( IQR 1.0°–8.5°) at the end of training. P-prism zone reaction times did not change significantly with training (P > 0.05). P-prism zone detection improved significantly (P = 0.01) from a pretraining median 70% (IQR 50%–88%) to 95% at the end of training (IQR 73%–98%). Three months after training improvements had regressed but performance was still better than pretraining. Conclusions Improved pointing accuracy for stimuli detected in prism-expanded vision of patients with hemianopia wearing 57Δ oblique p-prisms is possible and training appears to further improve detection. Translational Relevance This is the first use of this novel software to train adaptation of visual direction in patients with hemianopia wearing peripheral prisms. PMID:26933522
NASA Technical Reports Server (NTRS)
Ammann, E. O.; Massey, G. A.
1970-01-01
Inexpensive Rochon prisms can be produced by substituting easily polished glass for one-half of the calcite. Reciprocal polarizing properties of a conventional Rochon prism are retained, and angular separation between ordinary and extraordinary rays is the same as in all-calcite prism.
Goldmann tonometer error correcting prism: clinical evaluation.
McCafferty, Sean; Lim, Garrett; Duncan, William; Enikov, Eniko T; Schwiegerling, Jim; Levine, Jason; Kew, Corin
2017-01-01
Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness, stiffness, curvature, and tear film adhesion force. A comparative clinical study of 109 eyes measured IOP with CATS and Goldmann prisms. The IOP measurement differences between the CATS and Goldmann prisms were correlated to corneal thickness, hysteresis, and curvature. The CATS tonometer prism in correcting for Goldmann central corneal thickness (CCT) error demonstrated a reduction to <±2 mmHg in 97% of a standard CCT population. This compares to only 54% with CCT error <±2 mmHg using the Goldmann prism. Equal reductions of ~50% in errors due to corneal rigidity and curvature were also demonstrated. The results validate the CATS prism's improved accuracy and expected reduced sensitivity to Goldmann errors without IOP bias as predicted by mathematical modeling. The CATS replacement for the Goldmann prism does not change Goldmann measurement technique or interpretation.
NASA Astrophysics Data System (ADS)
Contreras-Reyes, Eduardo; Maksymowicz, Andrei; Lange, Dietrich; Grevemeyer, Ingo; Muñoz-Linford, Pamela; Moscoso, Eduardo
2017-11-01
Subduction megathrust earthquakes show complex rupture behaviour and large lateral variations of slip. However, the factors controlling seismic slip are still under debate. Here, we present 2-D velocity-depth tomographic models across four trench-perpendicular wide angle seismic profiles complemented with high resolution bathymetric data in the area of maximum coseismic slip of the Mw 8.8 Maule 2010 megathrust earthquake (central Chile, 34°-36°S). Results show an abrupt lateral velocity gradient in the trench-perpendicular direction (from 5.0 to 6.0 km/s) interpreted as the contact between the accretionary prism and continental framework rock whose superficial expression spatially correlates with the slope-shelf break. The accretionary prism is composed of two bodies: (1) an outer accretionary wedge (5-10 km wide) characterized by low seismic velocities of 1.8-3.0 km/s interpreted as an outer frontal prism of poorly compacted and hydrated sediment, and (2) the middle wedge (∼50 km wide) with velocities of 3.0-5.0 km/s interpreted as a middle prism composed by compacted and lithified sediment. In addition, the maximum average coseismic slip of the 2010 megathrust event is fairly coincident with the region where the accretionary prism and continental slope are widest (50-60 km wide), and the continental slope angle is low (<5°). We observe a similar relation along the rupture area of the largest instrumentally recorded Valdivia 1960 Mw 9.5 megathrust earthquake. For the case of the Maule event, published differential multibeam bathymetric data confirms that coseismic slip must have propagated up to ∼6 km landwards of the deformation front and hence practically the entire base of the middle prism. Sediment dewatering and compaction processes might explain the competent rheology of the middle prism allowing shallow earthquake rupture. In contrast, the outer frontal prism made of poorly consolidated sediment has impeded the rupture up to the deformation front as high resolution seismic reflection and multibeam bathymetric data have not showed evidence for new deformation in the trench region.
Lu, Zhaolin; Prather, Dennis W
2004-08-01
We present a method for parallel coupling from a single-mode fiber, or fiber ribbon, into a silicon-on-insulator waveguide for integration with silicon optoelectronic circuits. The coupler incorporates the advantages of the vertically tapered waveguides and prism couplers, yet offers the flexibility of planar integration. The coupler can be fabricated by use of either wafer polishing technology or gray-scale photolithography. When optimal coupling is achieved in our experimental setup, the coupler can be packaged by epoxy bonding to form a fiber-waveguide parallel coupler or connector. Two-dimensional electromagnetic calculation predicts a coupling efficiency of 77% (- 1.14-dB insertion loss) for a silicon-to-silicon coupler with a uniform tunnel layer. The coupling efficiency is experimentally achieved to be 46% (-3.4-dB insertion loss), excluding the loss in silicon and the reflections from the input surface and the output facet.
Photonic crystal microprisms obtained by carving artificial opals
NASA Astrophysics Data System (ADS)
Fenollosa, R.; Ibisate, M.; Rubio, S.; López, C.; Meseguer, F.; Sánchez-Dehesa, J.
2003-01-01
A method for fabrication of photonic crystal prisms is demonstrated. The procedure is based on micromanipulation techniques, here applied to artificial opals. By means of a microgrinder an opal prism comprising a single crystal (several tens of microns in size) has been carved with three different faces: (111), (110), and (100). The faces were morphologically characterized by scanning electron microscopy and their optical reflectance spectra measured and compared with the theoretical band structure.
Stereovision Imaging in Smart Mobile Phone Using Add on Prisms
NASA Astrophysics Data System (ADS)
Bar-Magen Numhauser, Jonathan; Zalevsky, Zeev
2014-03-01
In this work we present the use of a prism-based add on component installed on top of a smart phone to achieve stereovision capabilities using iPhone mobile operating system. Through these components and the combination of the appropriate application programming interface and mathematical algorithms the obtained results will permit the analysis of possible enhancements for new uses to such system, in a variety of areas including medicine and communications.
NASA Astrophysics Data System (ADS)
Haag, Justin M.; Van Gorp, Byron E.; Mouroulis, Pantazis; Thompson, David R.
2017-09-01
The airborne Portable Remote Imaging Spectrometer (PRISM) instrument is based on a fast (F/1.8) Dyson spectrometer operating at 350-1050 nm and a two-mirror telescope combined with a Teledyne HyViSI 6604A detector array. Raw PRISM data contain electronic and optical artifacts that must be removed prior to radiometric calibration. We provide an overview of the process transforming raw digital numbers to calibrated radiance values. Electronic panel artifacts are first corrected using empirical relationships developed from laboratory data. The instrument spectral response functions (SRF) are reconstructed using a measurement-based optimization technique. Removal of SRF effects from the data improves retrieval of true spectra, particularly in the typically low-signal near-ultraviolet and near-infrared regions. As a final step, radiometric calibration is performed using corrected measurements of an object of known radiance. Implementation of the complete calibration procedure maximizes data quality in preparation for subsequent processing steps, such as atmospheric removal and spectral signature classification.
Resultant vertical prism in toric soft contact lenses.
Sulley, Anna; Hawke, Ryan; Lorenz, Kathrine Osborn; Toubouti, Youssef; Olivares, Giovanna
2015-08-01
Rotational stability of toric soft contact lenses (TSCLs) is achieved using a range of designs. Designs utilising prism or peripheral ballast may result in residual prism in the optic zone. This study quantifies the vertical prism in the central 6mm present in TSCLs with various stabilisation methods. Vertical prism was computed using published refractive index and vertical thickness changes in the central optic zone on a full lens thickness map. Thickness maps were measured using scanning transmission microscopy. Designs tested were reusable, silicone hydrogel and hydrogel TSCLs: SofLens(®) Toric, PureVision(®)2 for Astigmatism, PureVision(®) Toric, Biofinity(®) Toric, Avaira(®) Toric, clariti(®) toric, AIR OPTIX(®) for ASTIGMATISM and ACUVUE OASYS(®) for ASTIGMATISM; with eight parameter combinations for each lens (-6.00DS to +3.00DS, -1.25DC, 90° and 180° axes). All TSCL designs evaluated had vertical prism in the optic zone except one which had virtually none (0.01Δ). Mean prism ranged from 0.52Δ to 1.15Δ, with three designs having prism that varied with sphere power. Vertical prism in ACUVUE OASYS(®) for ASTIGMATISM was significantly lower than all other TSCLs tested. TSCL designs utilising prism-ballast and peri-ballast for stabilisation have vertical prism in the central optic zone. In monocular astigmats fitted with a TSCL or those wearing a mix of toric designs, vertical prism imbalance could create or exacerbate disturbances in binocular vision function. Practitioners should be aware of this potential effect when selecting which TSCL designs to prescribe, particularly for monocular astigmats with pre-existing binocular vision anomalies, and when managing complaints of asthenopia in monocular astigmats. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Strategic Planning for Chronic Disease Prevention in Rural America: Looking Through a PRISM Lens.
Honeycutt, Amanda A; Wile, Kristina; Dove, Cassandra; Hawkins, Jackie; Orenstein, Diane
2015-01-01
Community-level strategic planning for chronic disease prevention. To share the outcomes of the strategic planning process used by Mississippi Delta stakeholders to prevent and reduce the negative impacts of chronic disease in their communities. A key component of strategic planning was participants' use of the Prevention Impacts Simulation Model (PRISM) to project the reduction, compared with the status quo, in deaths and costs from implementing interventions in Mississippi Delta communities. Participants in Mississippi Delta strategic planning meetings used PRISM, a user-friendly, evidence-based simulation tool that includes 22 categories of policy, systems, and environmental change interventions, to pose what-if questions that explore the likely short- and long-term effects of an intervention or any desired combination of the 22 categories of chronic disease intervention programs and policies captured in PRISM. These categories address smoking, air pollution, poor nutrition, and lack of physical activity. Strategic planning participants used PRISM outputs to inform their decisions and actions to implement interventions. Rural communities in the Mississippi Delta. A diverse group of 29 to 34 local chronic disease prevention stakeholders, known as the Mississippi Delta Strategic Alliance. Community plans and actions that were developed and implemented as a result of local strategic planning. Existing strategic planning efforts were complemented by the use of PRISM. The Mississippi Delta Strategic Alliance decided to implement new interventions to improve air quality and transportation and to expand existing interventions to reduce tobacco use and increase access to healthy foods. They also collaborated with the Department of Transportation to raise awareness and use of the current transportation network. The Mississippi Delta Strategic Alliance strategic planning process was complemented by the use of PRISM as a tool for strategic planning, which led to the implementation of new and strengthened chronic disease prevention interventions and policies in the Mississippi Delta.
Polarization manipulation in single refractive prism based holography lithography
NASA Astrophysics Data System (ADS)
Xiong, Wenjie; Xu, Yi; Xiao, Yujian; Lv, Xiaoxu; Wu, Lijun
2015-01-01
We propose theoretically and demonstrate experimentally a simple but effective strategy for polarization manipulation in single refractive prism based holographic lithography. By tuning the polarization of a single laser beam, we can obtain the pill shape interference pattern with a high-contrast where a complex optical setup and multiple polarizers are needed in the conventional holography lithography. Fabrication of pill shape two-dimensional polymer photonic crystals using one beam and one shoot holography lithography is shown as an example to support our theoretical results. This integrated polarization manipulation technique can release the crucial stability restrictions imposed on the multiple beams holography lithography.
Superiorization-based multi-energy CT image reconstruction
Yang, Q; Cong, W; Wang, G
2017-01-01
The recently-developed superiorization approach is efficient and robust for solving various constrained optimization problems. This methodology can be applied to multi-energy CT image reconstruction with the regularization in terms of the prior rank, intensity and sparsity model (PRISM). In this paper, we propose a superiorized version of the simultaneous algebraic reconstruction technique (SART) based on the PRISM model. Then, we compare the proposed superiorized algorithm with the Split-Bregman algorithm in numerical experiments. The results show that both the Superiorized-SART and the Split-Bregman algorithms generate good results with weak noise and reduced artefacts. PMID:28983142
Prism adaptation magnitude has differential influences on perceptual versus manual responses.
Striemer, Christopher L; Russell, Karyn; Nath, Priya
2016-10-01
Previous research has indicated that rightward prism adaptation can reduce symptoms of spatial neglect following right brain damage. In addition, leftward prism adaptation can create "neglect-like" patterns of performance in healthy adults on tasks that measure attention and spatial biases. Although a great deal of research has focused on which behaviors are influenced by prism adaptation, very few studies have focused directly on how the magnitude of visual shift induced by prisms might be related to the observed aftereffects, or the effects of prisms on measures of attentional and spatial biases. In the current study, we examined these questions by having groups of healthy adult participants complete manual line bisection and landmark tasks prior to and following adaptation to either 8.5° (15 diopter; n = 22) or 17° (30 diopter; n = 25) leftward shifting prisms. Our results demonstrated a significantly larger rightward shift in straight-ahead pointing (a measure of prism aftereffect) following adaptation to 17°, compared to 8.5° leftward shifting prisms. In addition, only 17° leftward shifting prisms resulted in a significant rightward shift in line bisection following adaptation. However, there was a significant change in performance on the landmark task pre- versus post-adaptation in both the 8.5° and 17° leftward shifting prism groups. Interestingly, correlation analyses indicated that changes in straight-ahead pointing pre- versus post-adaptation were positively correlated with changes in performance on the manual line bisection task, but not the landmark task. These data suggest that larger magnitudes of prism adaptation seem to have a greater influence on tasks that require a response with the adapted hand (i.e., line bisection), compared to tasks that only require a perceptual judgment (i.e., the landmark task). In addition, these data provide further evidence that the effects of prisms on manual and perceptual responses are not related to one another.
Rotatable prism for pan and tilt
NASA Technical Reports Server (NTRS)
Ball, W. B.
1980-01-01
Compact, inexpensive, motor-driven prisms change field of view of TV camera. Camera and prism rotate about lens axis to produce pan effect. Rotating prism around axis parallel to lens produces tilt. Size of drive unit and required clearance are little more than size of camera.
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2010 CFR
2010-04-01
... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber. The device may have angled mirrors to facilitate visualization of anatomical features. (b...
Pure rotation of a prism on a ramp
Zhao, Zhen; Liu, Caishan; Ma, Daolin
2014-01-01
In this work, we study a prism with a cross section in polygon rolling on a ramp inclined at a small angle. The prism under gravity rolls purely around each individual edge, intermittently interrupted by a sequence of face collisions between the side face of the prism and the ramp. By limiting the prism in a planar motion, we propose a mathematical model to deal with the events of the impacts. With a pair of laser-Doppler vibrometers, experiments are also conducted to measure the motions of various prisms made of different materials and with different edge number. Not only are good agreements achieved between our numerical and experimental results, but also an intriguing physical phenomenon is discovered: the purely rolling motion is nearly independent of the prism's materials, yet it is closely related to the prism's geometry. Imagine that an ideal circular section can be approximately equivalent to a polygon with a large enough edge number N, the finding presented in this paper may help discover the physical mechanism of rolling friction. PMID:25197242
Compound prism design principles, I
Hagen, Nathan; Tkaczyk, Tomasz S.
2011-01-01
Prisms have been needlessly neglected as components used in modern optical design. In optical throughput, stray light, flexibility, and in their ability to be used in direct-view geometry, they excel over gratings. Here we show that even their well-known weak dispersion relative to gratings has been overrated by designing doublet and double Amici direct-vision compound prisms that have 14° and 23° of dispersion across the visible spectrum, equivalent to 800 and 1300 lines/mm gratings. By taking advantage of the multiple degrees of freedom available in a compound prism design, we also show prisms whose angular dispersion shows improved linearity in wavelength. In order to achieve these designs, we exploit the well-behaved nature of prism design space to write customized algorithms that optimize directly in the nonlinear design space. Using these algorithms, we showcase a number of prism designs that illustrate a performance and flexibility that goes beyond what has often been considered possible with prisms. PMID:22423145
Tuncbag, Nurcan; Gursoy, Attila; Nussinov, Ruth; Keskin, Ozlem
2011-08-11
Prediction of protein-protein interactions at the structural level on the proteome scale is important because it allows prediction of protein function, helps drug discovery and takes steps toward genome-wide structural systems biology. We provide a protocol (termed PRISM, protein interactions by structural matching) for large-scale prediction of protein-protein interactions and assembly of protein complex structures. The method consists of two components: rigid-body structural comparisons of target proteins to known template protein-protein interfaces and flexible refinement using a docking energy function. The PRISM rationale follows our observation that globally different protein structures can interact via similar architectural motifs. PRISM predicts binding residues by using structural similarity and evolutionary conservation of putative binding residue 'hot spots'. Ultimately, PRISM could help to construct cellular pathways and functional, proteome-scale annotation. PRISM is implemented in Python and runs in a UNIX environment. The program accepts Protein Data Bank-formatted protein structures and is available at http://prism.ccbb.ku.edu.tr/prism_protocol/.
Pure rotation of a prism on a ramp.
Zhao, Zhen; Liu, Caishan; Ma, Daolin
2014-09-08
In this work, we study a prism with a cross section in polygon rolling on a ramp inclined at a small angle. The prism under gravity rolls purely around each individual edge, intermittently interrupted by a sequence of face collisions between the side face of the prism and the ramp. By limiting the prism in a planar motion, we propose a mathematical model to deal with the events of the impacts. With a pair of laser-Doppler vibrometers, experiments are also conducted to measure the motions of various prisms made of different materials and with different edge number. Not only are good agreements achieved between our numerical and experimental results, but also an intriguing physical phenomenon is discovered: the purely rolling motion is nearly independent of the prism's materials, yet it is closely related to the prism's geometry. Imagine that an ideal circular section can be approximately equivalent to a polygon with a large enough edge number N , the finding presented in this paper may help discover the physical mechanism of rolling friction.
Mechanism of Prism-Coupled Scanning Tunneling Microscope Light Emission
NASA Astrophysics Data System (ADS)
Iida, Wataru; Ahamed, Jamal U.; Katano, Satoshi; Uehara, Yoichi
2011-09-01
We have investigated the mechanism of scanning tunneling microscope light emission (STM-LE) in a prism-coupled configuration using finite difference time domain analysis. In this configuration, the sample is a metallic thin film evaporated on the bottom surface of a hemispherical glass prism. STM light emitted into the prism (prism-side emission) through the metallic film is measured. Since both localized surface plasmons (LSP) and surface plasmon polaritons (SPP) contribute to prism-side emission, this emission is stronger than that in conventional STM-LE measured from the sample surface side, which is radiated by LSP alone. We show that the spatial resolution of prism-side emission is determined not by the propagation length of SPP, but by the lateral size of LSP, similarly to conventional (i.e., tip side) STM-LE. Thus, we conclude that, by using the prism-coupled configuration, the signal level of STM-LE improves without the loss of spatial resolution attained in tip side emission.
NASA Astrophysics Data System (ADS)
Korhonen, Hannu; Syväluoto, Aki; Leskinen, Jari T. T.; Lappalainen, Reijo
2018-01-01
Nowadays, an environmental protection is needed for a number of optical applications in conditions quickly impairing the clarity of optical surfaces. Abrasion resistant optical coatings applied onto plastics are usually based on alumina or polysiloxane technology. In many applications transparent glasses and ceramics need a combination of abrasive and chemically resistant shielding or other protective solutions like coatings. In this study, we intended to test our hypothesis that clear and pore free alumina coating can be uniformly distributed on glass prisms by ultra short pulsed laser deposition (USPLD) technique to protect the sensitive surfaces against abrasives. Abrasive wear tests were carried out by the use of SiC emery paper using specified standard procedures. After the wear tests the measured transparencies of coated prisms turned out to be close those of the prisms before coating. The coating on sensitive surfaces consistently displayed enhanced wear resistance exhibiting still high quality, even after severe wear testing. Furthermore, the coating modified the surface properties towards hydrophobic nature in contrast to untreated prisms, which became very hydrophilic especially due to wear.
PRISM3/GISS Topographic Reconstruction
Sohl, Linda E.; Chandler, Mark A.; Schmunk, Robert B.; Mankoff, Ken; Jonas, Jeffrey A.; Foley, Kevin M.; Dowsett, Harry J.
2009-01-01
The PRISM3/GISS topographic reconstruction is one of the global data sets incorporated into a new reconstruction for the mid-Piacenzian warm interval of the Pliocene, at about 3.3 to 3.0 Ma. The PRISM3/GISS topography-gridded data set is a digitization of a graphical reconstruction, provided at 2 deg x 2 deg resolution and based on updated paleoaltimetry data and a refined land/ocean mask. Mid-Piacenzian topography as shown in this data set is generally quite similar to modern topography, with three notable differences: (1) the coastline as shown is 25 meters higher than modern sea level, reflecting the hypothesized reduction in ice sheet volume; (2) Hudson Bay is filled in to low elevation, in the absence of evidence for submergence at that time; and (3) the West Antarctic ice sheet is absent, permitting open seaways to exist in Ellsworth and Marie Byrd Lands. Two alternate ice sheet configurations with corresponding vegetation schemes are available; one is a minor modification of the PRISM2 ice reconstruction, and one is derived from the British Antarctic Survey Ice Sheet Model (BAS ISM).
Starostina, S V; Mareev, O V; Nikolenko, V N
2013-01-01
The objective of the present work was to develop a method for the modification of the vocal cord during the treatment of the patients presenting with unilateral laryngeal paralysis taking into consideration individual peculiarities of stereotopometric characteristics of the larynx in the subjects of different gender, neck structure, and body constitution. The earlier proposed method of laryngostereotopometry was employed in this study. The following body features were measured prior to surgery: the total length, acromial diameter, chest circumference, neck length and circumference; the degree of the fissure of glottis closure was measured by transnasal fibrolaryngoscopy. The transplant was cut out of the quadrangular cartilage of the nasal septum in the form of a prism having the base shaped as an isosceles triangle with the base equal to the width of the fissure of glottis; the vertical and horizontal sizes of the transplant were calculated from the formulas of multiple linear regression analysis. The autotransplant was introduced through the "window" in the plate of the shield-like cartilage between its internal perichondrium and the thyroarytenoid muscle of the arytenoid cartilage of the paralysed vocal cord in the horizontal direction in front of the site of attachment of the vocal cord of arytenoids cartilage up to the projection of the anterior commissure with fixation to the shield-like cartilage by a ligature.
NASA Astrophysics Data System (ADS)
Idris, N.; Maswati; Yusibani, E.
2018-05-01
The influence of the apex angle of a hollow prism used as a simple refractometer to the accuracy of a refractive index measurement of the edible oil samples was studied. The hollow prism was made from an ordinary commercial glass plate with a thickness of 2 mm. The apex angle of the constructed hollow prism was varied. The edible oil sample used in this study was palm oil, namely the packaged, branded oil sample and the bulk oil sample. For measuring the refractive index, the oil sample was filled in the constructed hollow prism, and then a helium-neon laser beam was passed through the oil sample at a certain angle of incidence. The angle of minimum deviation of the transmitted laser He-Ne beam was measured and then was used for calculating the refractive index of the oil sample. The refractive index measurement was made using the hollow prism with different apex angles, ranging from 300 to 600. The measurement accuracy was estimated by comparing the refractive index measured using the hollow prisms to that of obtained using a standard Abbe refractometer. It was found that the refractive index of the edible oil can be measured accurately by using the hollow prism. It was also found that the accuracy of the refractive index measurement significantly changes with the apex angle of the hollow prism. The refractive index values measured using this simple refractometer deviate up to 3,49% from the refractive index value measured using the standard Abbe refractometer, especially when the apex angle of the prism is 30°. The measurement results with high accuracies obtained when using the hollow prisms with apex angles of 450 and 600. The optimum apex angle for the present constructed hollow prism is 450. The refractive index obtained using the hollow prism with the apex angle of 450 is 1,4623 and 1,4438 for the bulk oil and the packed, branded oil samples, respectively. This result suggests that the apex angle of the prism used affects largely the accuracy of the refractive index measurement.
Estimating mountain basin-mean precipitation from streamflow using Bayesian inference
NASA Astrophysics Data System (ADS)
Henn, Brian; Clark, Martyn P.; Kavetski, Dmitri; Lundquist, Jessica D.
2015-10-01
Estimating basin-mean precipitation in complex terrain is difficult due to uncertainty in the topographical representativeness of precipitation gauges relative to the basin. To address this issue, we use Bayesian methodology coupled with a multimodel framework to infer basin-mean precipitation from streamflow observations, and we apply this approach to snow-dominated basins in the Sierra Nevada of California. Using streamflow observations, forcing data from lower-elevation stations, the Bayesian Total Error Analysis (BATEA) methodology and the Framework for Understanding Structural Errors (FUSE), we infer basin-mean precipitation, and compare it to basin-mean precipitation estimated using topographically informed interpolation from gauges (PRISM, the Parameter-elevation Regression on Independent Slopes Model). The BATEA-inferred spatial patterns of precipitation show agreement with PRISM in terms of the rank of basins from wet to dry but differ in absolute values. In some of the basins, these differences may reflect biases in PRISM, because some implied PRISM runoff ratios may be inconsistent with the regional climate. We also infer annual time series of basin precipitation using a two-step calibration approach. Assessment of the precision and robustness of the BATEA approach suggests that uncertainty in the BATEA-inferred precipitation is primarily related to uncertainties in hydrologic model structure. Despite these limitations, time series of inferred annual precipitation under different model and parameter assumptions are strongly correlated with one another, suggesting that this approach is capable of resolving year-to-year variability in basin-mean precipitation.
Optical design of infrared pyramid wavefront sensor for the MMT
NASA Astrophysics Data System (ADS)
Chen, Shaojie; Sivanandam, Suresh; Liu, Siqi; Veran, Jean-Pierre; Hinz, Phil; Mieda, Etsuko; Hardy, Tim; Lardiere, Olivier
2017-09-01
We report the optical design of an infrared (0.85-1.8 μm) pyramid wavefront sensor (IRPWFS) that is designed for the 6.5m MMT on telescope adaptive optics system using the latest developments in low-noise infrared avalanche photodiode arrays. The comparison between the pyramid and the double-roof prism based wavefront sensors and the evaluation of their micro pupils' quality are presented. According to our analysis, the use of two double-roof prisms with achromatic materials produces the competitive performance when compared to the traditional pyramid prism, which is difficult to manufacture. The final micro pupils on the image plane have the residual errors of pupil position, chromatism, and distortion within 1/10 pixel over the 2×2 arcsecond field of view, which meet the original design goals.
NASA Astrophysics Data System (ADS)
Braaten, D. A.; Holvoet, J. F.; Gogineni, S.
2003-12-01
The Radar Systems and Remote Sensing Laboratory at the University of Kansas (KU) has implemented extensive outreach activities focusing on Polar Regions as part of the Polar Radar for Ice Sheet Measurements (PRISM) project. The PRISM project is developing advanced intelligent remote sensing technology that involves radar systems, an autonomous rover, and communications systems to measure detailed ice sheet characteristics, and to determine bed conditions (frozen or wet) below active ice sheets in both Greenland and Antarctica. These measurements will provide a better understanding of the response of polar ice sheets to global climate change and the resulting impact the ice sheets will have on sea level rise. Many of the research and technological development aspects of the PRISM project, such as robotics, radar systems, climate change and exploration of harsh environments, can kindle an excitement and interest in students about science and technology. These topics form the core of our K-12 education and training outreach initiatives, which are designed to capture the imagination of young students, and prompt them to consider an educational path that will lead them to scientific or engineering careers. The K-12 PRISM outreach initiatives are being developed and implemented in a collaboration with the Advanced Learning Technology Program (ALTec) of the High Plains Regional Technology in Education Consortium (HPR*TEC). ALTec is associated with the KU School of Education, and is a well-established educational research center that develops and hosts web tools to enable teachers nationwide to network, collaborate, and share resources with other teachers. An example of an innovative and successful web interface developed by ALTec is called TrackStar. Teachers can use TrackStar over the Web to develop interactive, resource-based lessons (called tracks) on-line for their students. Once developed, tracks are added to the TrackStar database and can be accessed and modified (if necessary) by teachers everywhere. The PRISM project has added a search engine for polar related tracks, and has developed numerous new tracks on robotics, polar exploration, and climate change under the guidance of a K-12 teacher advisory group. The PRISM project is also developing and hosting several other web-based lesson design tools and resources for K-12 educators and students on the PRISM project web page (http://www.ku-prism.org). These tools and resources include: i) "Polar Scientists and Explorers, Past and Present" covering the travels and/or unknown fate of polar explorers and scientists; ii) "Polar News" providing links to current news articles related to polar regions; iii) "Letter of Global Concern", which is a tool to help students draft a letter to a politician, government official, or business leader; iv) "Graphic Sleuth", which is an online utility that allows teachers to make lessons for student use; v) "Bears on Ice" for students in grades K - 6 that can follow the adventures of two stuffed bears that travel with scientists into polar regions; and vi) "K-12 Polar Resources," which provides teachers with images, information, TrackStar lessons, and a search engine designed to identify polar related lessons. In our presentation, we will describe and show examples of these tools and resources, and provide an assessment of their popularity with teachers nationwide.
Development and application of GIS-based PRISM integration through a plugin approach
NASA Astrophysics Data System (ADS)
Lee, Woo-Seop; Chun, Jong Ahn; Kang, Kwangmin
2014-05-01
A PRISM (Parameter-elevation Regressions on Independent Slopes Model) QGIS-plugin was developed on Quantum GIS platform in this study. This Quantum GIS plugin system provides user-friendly graphic user interfaces (GUIs) so that users can obtain gridded meteorological data of high resolutions (1 km × 1 km). Also, this software is designed to run on a personal computer so that it does not require an internet access or a sophisticated computer system. This module is a user-friendly system that a user can generate PRISM data with ease. The proposed PRISM QGIS-plugin is a hybrid statistical-geographic model system that uses coarse resolution datasets (APHRODITE datasets in this study) with digital elevation data to generate the fine-resolution gridded precipitation. To validate the performance of the software, Prek Thnot River Basin in Kandal, Cambodia is selected for application. Overall statistical analysis shows promising outputs generated by the proposed plugin. Error measures such as RMSE (Root Mean Square Error) and MAPE (Mean Absolute Percentage Error) were used to evaluate the performance of the developed PRISM QGIS-plugin. Evaluation results using RMSE and MAPE were 2.76 mm and 4.2%, respectively. This study suggested that the plugin can be used to generate high resolution precipitation datasets for hydrological and climatological studies at a watershed where observed weather datasets are limited.
An Improved Prism for Use in Laser Resonators
1981-08-01
reflection (TIR) prisms , will be shown to give significant advantages over the use of Porro prisms when used in polarisation coupled laser resonators . 2... resonator as shown in figure 2. As in the case of the crossed- Porro laser an in-line or folded configuration can be used. The compound TIR prism at the...thrashold, etc, rather than on refractive index, as in the case of Porro prisms . In conventional Q-switched Nd:YAG resonators , replacement of the 100
The Geometric Theory of Roof Reflector Resonators
1976-12-01
reflector, if properly oriented, (The terms "roof-top prism ," "right-angle prism ," and - incorrectly - " Porro prism " are encountered in .the literature...Q-switch prisms ) in laser resonators have been infrequent compared to the attention given spherical mirrors. This chapter summarizes the relevant...designator (Refs 42 and 43). In one experiment, a 900 roof prism was tested in a resonator with a 70% reflecting filat mirror. Thus, in Fig. 2, the right roof
Successful treatment of diplopia with prism improves health-related quality of life.
Hatt, Sarah R; Leske, David A; Liebermann, Laura; Holmes, Jonathan M
2014-06-01
To report change in strabismus-specific health-related quality of life (HRQOL) following treatment with prism. Retrospective cross-sectional study. Thirty-four patients with diplopia (median age 63, range 14-84 years) completed the Adult Strabismus-20 questionnaire (100-0, best to worst HRQOL) and a diplopia questionnaire in a clinical practice before prism and in prism correction. Before prism, diplopia was "sometimes" or worse for reading and/or straight-ahead distance. Prism treatment success was defined as diplopia rated "never" or "rarely" on the diplopia questionnaire for reading and straight-ahead distance. Failure was defined as worsening or no change in diplopia. For both successes and failures, mean Adult Strabismus-20 scores were compared before prism and in prism correction. Each of the 4 Adult Strabismus-20 domains (self-perception, interactions, reading function, and general function) was analyzed separately. Twenty-three of 34 (68%) were successes and 11 (32%) were failures. For successes, reading function improved from 57 ± 27 (SD) before prism to 69 ± 27 in-prism correction (difference 12 ± 20, 95% CI 3.2-20.8, P = .02) and general function improved from 66 ± 25 to 80 ± 18 (difference 14 ± 22, 95% CI 5.0-23.6, P = .003). Self-perception and interaction domains remained unchanged (P > .2). For failures there was no significant change in Adult Strabismus-20 score on any domain (P > .4). Successful correction of diplopia with prism is associated with improvement in strabismus-specific HRQOL, specifically reading function and general function. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ghezali, S.; Taleb, A.
2008-09-01
A research project at the "Laboratoire d'électronique quantique" consists in a theoretical study of the reflection and diffraction phenomena via an atomic mirror. This poster presents the principle of an atomic mirror. Many groups in the world have constructed this type of atom optics experiments such as in Paris-Orsay-Villetaneuse (France), Stanford-Gaithersburg (USA), Munich-Heidelberg (Germany), etc. A laser beam goes into a prism with an incidence bigger than the critical incidence. It undergoes a total reflection on the plane face of the prism and then exits. The transmitted resulting wave out of the prism is evanescent and repulsive as the frequency detuning of the laser beam compared to the atomic transition δ = ωL-ω0 is positive. The cold atomic sample interacts with this evanescent wave and undergoes one or more elastic bounces by passing into backward points in its trajectory because the atoms' kinetic energy (of the order of the μeV) is less than the maximum of the dipolar potential barrier ℏΩ2/Δ where Ω is the Rabi frequency [1]. In fact, the atoms are cooled and captured in a magneto-optical trap placed at a distance of the order of the cm above the prism surface. The dipolar potential with which interact the slow atoms is obtained for a two level atom in a case of a dipolar electric transition (D2 Rubidium transition at a wavelength of 780nm delivered by a Titane-Saphir laser between a fundamental state Jf = l/2 and an excited state Je = 3/2). This potential is corrected by an attractive Van der Waals term which varies as 1/z3 in the Lennard-Jones approximation (typical atomic distance of the order of λ0/2π where λ0 is the laser wavelength) and in 1/z4 if the distance between the atom and its image in the dielectric is big in front of λ0/2π. This last case is obtained in a quantum electrodynamic calculation by taking into account an orthornormal base [2]. We'll examine the role of spontaneous emission for which the rate is inversely proportional to the detuning δ and is responsible of the non specular aspect of the atomic reflection (atomic diffusion). In the contrary, we note that the specularity of the reflection preserve the coherence of the atomic wave packet. The atoms will constitute a probe of the rugosity of the prism surface which can be imperfect or super-polished.
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
NASA Astrophysics Data System (ADS)
Leirião, Sílvia; He, Xin; Christiansen, Lars; Andersen, Ole B.; Bauer-Gottwein, Peter
2009-02-01
SummaryTotal water storage change in the subsurface is a key component of the global, regional and local water balances. It is partly responsible for temporal variations of the earth's gravity field in the micro-Gal (1 μGal = 10 -8 m s -2) range. Measurements of temporal gravity variations can thus be used to determine the water storage change in the hydrological system. A numerical method for the calculation of temporal gravity changes from the output of hydrological models is developed. Gravity changes due to incremental prismatic mass storage in the hydrological model cells are determined to give an accurate 3D gravity effect. The method is implemented in MATLAB and can be used jointly with any hydrological simulation tool. The method is composed of three components: the prism formula, the MacMillan formula and the point-mass approximation. With increasing normalized distance between the storage prism and the measurement location the algorithm switches first from the prism equation to the MacMillan formula and finally to the simple point-mass approximation. The method was used to calculate the gravity signal produced by an aquifer pump test. Results are in excellent agreement with the direct numerical integration of the Theis well solution and the semi-analytical results presented in [Damiata, B.N., and Lee, T.-C., 2006. Simulated gravitational response to hydraulic testing of unconfined aquifers. Journal of Hydrology 318, 348-359]. However, the presented method can be used to forward calculate hydrology-induced temporal variations in gravity from any hydrological model, provided earth curvature effects can be neglected. The method allows for the routine assimilation of ground-based gravity data into hydrological models.
Nathan, Meena; Karamichalis, John M; Liu, Hua; del Nido, Pedro; Pigula, Frank; Thiagarajan, Ravi; Bacha, Emile A
2011-11-01
Our objective was to define the relationship between surgical technical performance score, intraoperative adverse events, and major postoperative adverse events in complex pediatric cardiac repairs. Infants younger than 6 months were prospectively followed up until discharge from the hospital. Technical performance scores were graded as optimal, adequate, or inadequate based on discharge echocardiograms and need for reintervention after initial surgery. Case complexity was determined by Risk Adjustment in Congenital Heart Surgery (RACHS-1) category, and preoperative illness severity was assessed by Pediatric Risk of Mortality (PRISM) III score. Intraoperative adverse events were prospectively monitored. Outcomes were analyzed using nonparametric methods and a logistic regression model. A total of 166 patients (RACHS 4-6 [49%]), neonates [50%]) were observed. Sixty-one (37%) had at least 1 intraoperative adverse event, and 47 (28.3%) had at least 1 major postoperative adverse event. There was no correlation between intraoperative adverse events and RACHS, preoperative PRISM III, technical performance score, or postoperative adverse events on multivariate analysis. For the entire cohort, better technical performance score resulted in lower postoperative adverse events, lower postoperative PRISM, and lower length of stay and ventilation time (P < .001). Patients requiring intraoperative revisions fared as well as patients without, provided the technical score was at least adequate. In neonatal and infant open heart repairs, technical performance score is one of the main predictors of postoperative morbidity. Outcomes are not affected by intraoperative adverse events, including surgical revisions, provided technical performance score is at least adequate. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Development and validation of PRISM: a survey tool to identify diabetes self-management barriers.
Cox, Elizabeth D; Fritz, Katie A; Hansen, Kristofer W; Brown, Roger L; Rajamanickam, Victoria; Wiles, Kaelyn E; Fate, Bryan H; Young, Henry N; Moreno, Megan A
2014-04-01
Although most children with type 1 diabetes do not achieve optimal glycemic control, no systematic method exists to identify and address self-management barriers. This study develops and validates PRISM (Problem Recognition in Illness Self-Management), a survey-based tool for efficiently identifying self-management barriers experienced by children/adolescents with diabetes and their parents. Adolescents 13 years and older and parents of children 8 years and older visiting for routine diabetes management (n=425) were surveyed about self-management barriers. HbA1c was abstracted from the electronic health record. To develop PRISM, exploratory and confirmatory factor analyses were used. To assess validity, the association of PRISM scores with HbA1c was examined using linear regression. Factor analyses of adolescent and parent data yielded well-fitting models of self-management barriers, reflecting the following domains: (1) Understanding and Organizing Care, (2) Regimen Pain and Bother, (3) Denial of Disease and Consequences, and (4) Healthcare Team, (5) Family, or (6) Peer Interactions. All models exhibited good fit, with χ(2) ratios<2.21, root mean square errors of approximation<0.09, Confirmatory Fit Indices and Tucker-Lewis Indices both >0.92, and weighted root mean square residuals<1.71. Greater PRISM barrier scores were significantly associated with higher HbA1cs. Our findings suggest at least six different domains exist within self-management barriers, nearly all of which are significantly related to HbA1c. PRISM could be used in clinical practice to identify each child and family's unique self-management barriers, allowing existing self-management resources to be tailored to the family's barriers, ultimately improving effectiveness of such services. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Development and Validation of PRISM: A Survey Tool to Identify Diabetes Self-Management Barriers
Cox, Elizabeth D.; Fritz, Katie A.; Hansen, Kristofer W.; Brown, Roger L.; Rajamanickam, Victoria; Wiles, Kaelyn E.; Fate, Bryan H.; Young, Henry N.; Moreno, Megan A.
2014-01-01
Aims Although most children with type 1 diabetes don’t achieve optimal glycemic control, no systematic method exists to identify and address self-management barriers. This study develops and validates PRISM (Problem Recognition in Illness Self-Management), a survey-based tool for efficiently identifying self-management barriers experienced by children/adolescents with diabetes and their parents. Methods Adolescents 13 years and older and parents of children 8 years and older visiting for routine diabetes management (n=425) were surveyed about self-management barriers. HbA1c was abstracted from the electronic health record. To develop PRISM, exploratory and confirmatory factor analyses were used. To assess validity, the association of PRISM scores with HbA1c was examined using linear regression. Results Factor analyses of adolescent and parent data yielded well-fitting models of self-management barriers, reflecting the following domains: 1) Understanding and Organizing Care, 2) Regimen Pain and Bother, 3) Denial of Disease and Consequences, and 4) Healthcare Team, 5) Family, or 6) Peer Interactions. All models exhibited good fit, with X2 ratios<2.21, root mean square errors of approximation<0.09, Confirmatory Fit Indices and Tucker-Lewis Indices both >0.92, and weighted root mean square residuals<1.71. Greater PRISM barrier scores were significantly associated with higher HbA1cs. Conclusions Our findings suggest at least six different domains exist within self-management barriers, nearly all of which are significantly related to HbA1c. PRISM could be used in clinical practice to identify each child and family’s unique self-management barriers, allowing existing self-management resources to be tailored to the family’s barriers, ultimately improving effectiveness of such services. PMID:24552680
Illusory Reversal of Causality between Touch and Vision has No Effect on Prism Adaptation Rate.
Tanaka, Hirokazu; Homma, Kazuhiro; Imamizu, Hiroshi
2012-01-01
Learning, according to Oxford Dictionary, is "to gain knowledge or skill by studying, from experience, from being taught, etc." In order to learn from experience, the central nervous system has to decide what action leads to what consequence, and temporal perception plays a critical role in determining the causality between actions and consequences. In motor adaptation, causality between action and consequence is implicitly assumed so that a subject adapts to a new environment based on the consequence caused by her action. Adaptation to visual displacement induced by prisms is a prime example; the visual error signal associated with the motor output contributes to the recovery of accurate reaching, and a delayed feedback of visual error can decrease the adaptation rate. Subjective feeling of temporal order of action and consequence, however, can be modified or even reversed when her sense of simultaneity is manipulated with an artificially delayed feedback. Our previous study (Tanaka et al., 2011; Exp. Brain Res.) demonstrated that the rate of prism adaptation was unaffected when the subjective delay of visual feedback was shortened. This study asked whether subjects could adapt to prism adaptation and whether the rate of prism adaptation was affected when the subjective temporal order was illusory reversed. Adapting to additional 100 ms delay and its sudden removal caused a positive shift of point of simultaneity in a temporal order judgment experiment, indicating an illusory reversal of action and consequence. We found that, even in this case, the subjects were able to adapt to prism displacement with the learning rate that was statistically indistinguishable to that without temporal adaptation. This result provides further evidence to the dissociation between conscious temporal perception and motor adaptation.
IODP Expedition 338: Riser and Riserless Drilling Along the NanTroSEIZE Transect
NASA Astrophysics Data System (ADS)
Strasser, M.; Moore, G. F.; Dugan, B.; Kanagawa, K.; Toczko, S.
2013-12-01
Integrated Ocean Drilling Program (IODP) Expedition 338 provided new constraints on the Kumano Basin sediments, the accretionary prism inner wedge, the seaward extension of the megasplay fault, the architecture and mechanics of landslides, and the alteration of oceanic basement of the incoming Philippine Sea plate. This was accomplished through riser and riserless drilling, logging while drilling (LWD), and cuttings and core analysis. Cuttings and LWD analyses at Hole C0002F reveal two lithologic units in the prism inner wedge which are separated by a prominent fault zone at ~1640 mbsf. Mud-gases from the inner prism show high concentrations at the top of the wedge that decrease, but become more thermogenic, with depth. These data are from the previously unaccessed deeper part of the Nankai accretionary prism. Riserless coring at Site C0002 provided data across the gas hydrate zone of the Kumano Basin, across the Kumano Basin-accretionary prism unconformity, and in the uppermost accretionary prism. Within the Kumano basin section, gas and porewater geochemistry documents microbial methane gas in hydrates that are disseminated in sandy layers. Multiple penetrations of the Kumano Basin-accretionary prism boundary and 3D seismic data show that the boundary is erosive and complex. LWD (Site C0018) and coring and LWD (Site C0021) augment existing data to better understand submarine landslide dynamics and mass-transport deposit (MTD) emplacement processes. Previous coring at Site C0018 identified six MTDs, but only two MTD intervals were detected in resistivity images that show high angle, randomly oriented bedding. Site C0021, located more proximal to the MTD source, provides constraint on MTD variability. Correlation across the sites reveals a thick MTD with an erosional base characterized by a shear zone in muddy sediments vs. a translational basal surface within coarse volcaniclastic sand in the proximal and distal/lateral areas, respectively. LWD data and cores from Site C0022 characterize the uppermost 400 m of sediment near the tip of the megasplay fault zone where it approaches the seafloor. This fault zone is inferred to be located at the interval of 80-145 mbsf, based on biostratigraphic reversals, bedding dips >20°, porosity anomalies and a change in trend of interstitial water chemistry data. LWD at Site C0012 primarily yielded insights into the nature of the incoming oceanic crust. Two crustal units were identified based on LWD data. The upper unit had gamma ray variations that may indicate changes in the crustal alteration or sediment-basalt interlayering. The deeper unit has little variation in log properties, suggesting the presence of uniform or fresh basalt. Together these data provide new constraints on the overall architecture and mechanics of the Nankai subduction zone.
ERIC Educational Resources Information Center
Hall, Philippa
2015-01-01
International debates on the aims and purposes of entrepreneurship education in universities are examined in this paper through the prism of a policy critique of recent English higher education initiatives. The Department of Business, Innovation and Skills (BIS) policy to integrate rather than "add on" enterprise education throughout…
Experimental static aerodynamics of a regular hexagonal prism in a low density hypervelocity flow
NASA Technical Reports Server (NTRS)
Guy, R. W.; Mueller, J. N.; Lee, L. P.
1972-01-01
A regular hexagonal prism, having a fineness ratio of 1.67, has been tested in a wind tunnel to determine its static aerodynamic characteristics in a low-density hypervelocity flow. The prism tested was a 1/4-scale model of the graphite heat shield which houses the radioactive fuel for the Viking spacecraft auxiliary power supply. The basic hexagonal prism was also modified to simulate a prism on which ablation of one of the six side flats had occurred. This modified hexagonal prism was tested to determine the effects on the aerodynamic characteristics of a shape change caused by ablation during a possible side-on stable reentry.
PRogram In Support of Moms (PRISM): Development and Beta Testing.
Byatt, Nancy; Pbert, Lori; Hosein, Safiyah; Swartz, Holly A; Weinreb, Linda; Allison, Jeroan; Ziedonis, Douglas
2016-08-01
Most women with perinatal depression do not receive depression treatment. The authors describe the development and beta testing of a new program, PRogram In Support of Moms (PRISM), to improve treatment of perinatal depression in obstetric practices. A multidisciplinary work group of seven perinatal and behavioral health professionals was convened to design, refine, and beta-test PRISM in an obstetric practice. Iterative feedback and problem solving facilitated development of PRISM components, which include provider training and a toolkit, screening procedures, implementation assistance, and access to immediate psychiatric consultation. Beta testing with 50 patients over two months demonstrated feasibility and suggested that PRISM may improve provider screening rates and self-efficacy to address depression. On the basis of lessons learned, PRISM will be enhanced to integrate proactive patient engagement and monitoring into obstetric practices. PRISM may help overcome patient-, provider-, and system-level barriers to managing perinatal depression in obstetric settings.
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
Symmetry Breaking Analysis of Prism Adaptation's Latent Aftereffect
ERIC Educational Resources Information Center
Frank, Till D.; Blau, Julia J. C.; Turvey, Michael T.
2012-01-01
The effect of prism adaptation on movement is typically reduced when the movement at test (prisms off) differs on some dimension from the movement at training (prisms on). Some adaptation is latent, however, and only revealed through further testing in which the movement at training is fully reinstated. Applying a nonlinear attractor dynamic model…
Left-Deviating Prism Adaptation in Left Neglect Patient: Reflexions on a Negative Result
Luauté, Jacques; Jacquin-Courtois, Sophie; O'Shea, Jacinta; Christophe, Laure; Rode, Gilles; Boisson, Dominique; Rossetti, Yves
2012-01-01
Adaptation to right-deviating prisms is a promising intervention for the rehabilitation of patients with left spatial neglect. In order to test the lateral specificity of prism adaptation on left neglect, the present study evaluated the effect of left-deviating prism on straight-ahead pointing movements and on several classical neuropsychological tests in a group of five right brain-damaged patients with left spatial neglect. A group of healthy subjects was also included for comparison purposes. After a single session of exposing simple manual pointing to left-deviating prisms, contrary to healthy controls, none of the patients showed a reliable change of the straight-ahead pointing movement in the dark. No significant modification of attentional paper-and-pencil tasks was either observed immediately or 2 hours after prism adaptation. These results suggest that the therapeutic effect of prism adaptation on left spatial neglect relies on a specific lateralized mechanism. Evidence for a directional effect for prism adaptation both in terms of the side of the visuomanual adaptation and therefore possibly in terms of the side of brain affected by the stimulation is discussed. PMID:23050168
PRISM: Enmeshment of illness and self-schema.
Denton, Fiona; Sharpe, Louise; Schrieber, Leslie
2004-01-01
The Pictorial Representation of Illness and Self Measure (PRISM) is a recently developed tool purported to assess burden of suffering due to illness. The nature of the PRISM task suggests a conceptual link to the illness self-schema construct hypothesised to be present in some individuals with chronic illness. This study investigates the relationship between PRISM and schema as measured by cognitive bias. 43 patients with systemic lupus erythematosus (SLE) completed an information-processing task involving endorsement of positive and negative illness words as descriptors of themselves, followed by free recall of the words. The outcome measures were endorsement and recall bias for negative illness words. Patients also completed the PRISM task and were assessed on other physical and psychological variables. PRISM did not correlate significantly with age, depression, functional impairment or disease activity. In a multiple regression analysis, only recall bias made an independent contribution to PRISM. Illness self-schema appears to play a significant role in determining the way in which SLE patients complete the PRISM task. This is discussed in light of a schema enmeshment model recently proposed in the cognitive bias literature. Copyright 2004 S. Karger AG, Basel
ERIC Educational Resources Information Center
Turton, Roger
2016-01-01
"Mathematical Lens" uses photographs as a springboard for mathematical inquiry and appears in every issue of "Mathematics Teacher." Recently while dismantling an old wooden post-and-rail fence, Roger Turton noticed something very interesting when he piled up the posts and rails together in the shape of a prism. The total number…
Standardization of motion sickness induced by left-right and up-down reversing prisms
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Vanderploeg, J. M.; Brumley, E. A.; Kolafa, J. J.; Wood, S. J.
1990-01-01
Reversing prisms are known to produce symptoms of motion sickness, and have been used to provide a chronic stimulus for training subjects on symptom recognition and regulation. However, testing procedures with reversing prisms have not been standardized. A set of procedures were evaluated which could be standardized using prisms for provocation and to compare the results between Right/Left Reversing Prisms (R/L-RP) and Up/Down Reversing Prisms (U/D-RP). Fifteen subjects were tested with both types of prisms using a self paced walking course throughout the laboratory with work stations established at specified intervals. The work stations provided tasks requiring eye-hand-foot coordination and various head movements. Comparisons were also made between these prism tests and two other standardized susceptibility tests, the KC-135 parabolic static chair test and the Staircase Velocity Motion Test (SVMT). Two different types of subjective symptom reports were compared. The R/L-RP were significantly more provocative than the U/D-RP. The incidence of motion sickness symptoms for the R/L-RP was similar to the KC-135 parabolic static chair test. Poor correlations were found between the prism tests and the other standardized susceptibility tests, which might indicate that different mechanisms are involved in provoking motion sickness for these different tests.
Activation of the cerebellar cortex and the dentate nucleus in a prism adaptation fMRI study.
Küper, Michael; Wünnemann, Meret J S; Thürling, Markus; Stefanescu, Roxana M; Maderwald, Stefan; Elles, Hans G; Göricke, Sophia; Ladd, Mark E; Timmann, Dagmar
2014-04-01
During prism adaptation two types of learning processes can be distinguished. First, fast strategic motor control responses are predominant in the early course of prism adaptation to achieve rapid error correction within few trials. Second, slower spatial realignment occurs among the misaligned visual and proprioceptive sensorimotor coordinate system. The aim of the present ultra-highfield (7T) functional magnetic resonance imaging (fMRI) study was to explore cerebellar cortical and dentate nucleus activation during the course of prism adaptation in relation to a similar visuomotor task without prism exposure. Nineteen young healthy participants were included into the study. Recently developed normalization procedures were applied for the cerebellar cortex and the dentate nucleus. By means of subtraction analysis (early prism adaptation > visuomotor, early prism adaptation > late prism adaptation) we identified ipsilateral activation associated with strategic motor control responses within the posterior cerebellar cortex (lobules VIII and IX) and the ventro-caudal dentate nucleus. During the late phase of adaptation we observed pronounced activation of posterior parts of lobule VI, although subtraction analyses (late prism adaptation > visuomotor) remained negative. These results are in good accordance with the concept of a representation of non-motor functions, here strategic control, within the ventro-caudal dentate nucleus. Copyright © 2013 Wiley Periodicals, Inc.
PRISM 3: expanded prediction of natural product chemical structures from microbial genomes
Skinnider, Michael A.; Merwin, Nishanth J.; Johnston, Chad W.
2017-01-01
Abstract Microbial natural products represent a rich resource of pharmaceutically and industrially important compounds. Genome sequencing has revealed that the majority of natural products remain undiscovered, and computational methods to connect biosynthetic gene clusters to their corresponding natural products therefore have the potential to revitalize natural product discovery. Previously, we described PRediction Informatics for Secondary Metabolomes (PRISM), a combinatorial approach to chemical structure prediction for genetically encoded nonribosomal peptides and type I and II polyketides. Here, we present a ground-up rewrite of the PRISM structure prediction algorithm to derive prediction of natural products arising from non-modular biosynthetic paradigms. Within this new version, PRISM 3, natural product scaffolds are modeled as chemical graphs, permitting structure prediction for aminocoumarins, antimetabolites, bisindoles and phosphonate natural products, and building upon the addition of ribosomally synthesized and post-translationally modified peptides. Further, with the addition of cluster detection for 11 new cluster types, PRISM 3 expands to detect 22 distinct natural product cluster types. Other major modifications to PRISM include improved sequence input and ORF detection, user-friendliness and output. Distribution of PRISM 3 over a 300-core server grid improves the speed and capacity of the web application. PRISM 3 is available at http://magarveylab.ca/prism/. PMID:28460067
Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia
Bowers, Alex R.; Keeney, Karen; Peli, Eli
2013-01-01
Objective To evaluate the efficacy of real relative to sham peripheral prism glasses for patients with complete homonymous hemianopia and without visual neglect. Methods Patients recruited at 13 clinics were allocated by minimization into a double-masked, crossover trial with two groups. One group received real (57Δ) oblique and sham (≤ 5Δ) horizontal prisms; the other received real horizontal and sham oblique, in counterbalanced order. A masked data collector at each clinic administered questionnaires after each 4-week crossover period. Main outcome measure The primary outcome was the overall difference, across the two periods of the crossover, between the proportion of participants who wanted to continue with (said “yes” to) real prisms and the proportion who said yes to sham prisms. The secondary outcome was the difference in perceived mobility improvement between real and sham prisms. Results Of 73 patients randomized, 61 completed the crossover. A significantly higher proportion said yes to real than sham prisms (64% vs. 36%; odds ratio 5.3, 95% CI 1.8 to 21.0). Participants who continued wear after 6 months reported greater improvement in mobility with real than sham prisms at crossover end (p=0.002); participants who discontinued wear reported no difference. Conclusion Real peripheral prism glasses were more helpful for obstacle avoidance when walking than sham glasses, with no differences between the horizontal and oblique designs. Applications to clinical practice Peripheral prism glasses provide a simple and inexpensive mobility rehabilitation intervention for hemianopia. PMID:24201760
Successful treatment of diplopia with prism improves health-related quality of life
Hatt, Sarah R.; Leske, David A.; Liebermann, Laura; Holmes, Jonathan M.
2014-01-01
Purpose To report change in strabismus-specific health-related quality of life (HRQOL) following treatment with prism. Design Retrospective cross-sectional study Methods Thirty-four patients with diplopia (median age 63, range 14 to 84 years) completed the Adult Strabismus-20 questionnaire (100 to 0, best to worst HRQOL) and a diplopia questionnaire in a clinical practice before prism and in prism correction. Before prism, diplopia was “sometimes” or worse for reading and/or straight ahead distance. Prism treatment success was defined as diplopia rated “never” or “rarely” on the Diplopia Questionnaire for reading and straight ahead distance. Failure was defined as worsening or no change in diplopia. For both successes and failures, mean Adult Strabismus -20 scores were compared pre-prism and in prism correction. Each of the four Adult Strabismus -20 domains (Self-perception, Interactions, Reading function and General function) were analyzed separately. Results Twenty-three (68%) of 34 were successes and 11 (32%) were failures. For successes, Reading Function improved from 57 ± 27 (SD) before prism to 69 ± 27 in-prism correction (difference 12 ± 20, 95% CI 3.2 to 20.8, P=0.02) and General Function improved from 66 ± 25 to 80 ± 18 (difference 14 ± 22, 95% CI 5.0 to 23.6, P=0.003). Self-perception and Interaction domains remained unchanged (P>0.2). For failures there was no significant change in Adult Strabismus -20 score on any domain (P>0.4). Conclusions Successful correction of diplopia with prism is associated with improvement in strabismus-specific HRQOL, specifically reading function and general function. PMID:24561171
Goldmann tonometry tear film error and partial correction with a shaped applanation surface.
McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M
2018-01-01
The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.
Kinematic markers dissociate error correction from sensorimotor realignment during prism adaptation.
O'Shea, Jacinta; Gaveau, Valérie; Kandel, Matthieu; Koga, Kazuo; Susami, Kenji; Prablanc, Claude; Rossetti, Yves
2014-03-01
This study investigated the motor control mechanisms that enable healthy individuals to adapt their pointing movements during prism exposure to a rightward optical shift. In the prism adaptation literature, two processes are typically distinguished. Strategic motor adjustments are thought to drive the pattern of rapid endpoint error correction typically observed during the early stage of prism exposure. This is distinguished from so-called 'true sensorimotor realignment', normally measured with a different pointing task, at the end of prism exposure, which reveals a compensatory leftward 'prism after-effect'. Here, we tested whether each mode of motor compensation - strategic adjustments versus 'true sensorimotor realignment' - could be distinguished, by analyzing patterns of kinematic change during prism exposure. We hypothesized that fast feedforward versus slower feedback error corrective processes would map onto two distinct phases of the reach trajectory. Specifically, we predicted that feedforward adjustments would drive rapid compensation of the initial (acceleration) phase of the reach, resulting in the rapid reduction of endpoint errors typically observed early during prism exposure. By contrast, we expected visual-proprioceptive realignment to unfold more slowly and to reflect feedback influences during the terminal (deceleration) phase of the reach. The results confirmed these hypotheses. Rapid error reduction during the early stage of prism exposure was achieved by trial-by-trial adjustments of the motor plan, which were proportional to the endpoint error feedback from the previous trial. By contrast, compensation of the terminal reach phase unfolded slowly across the duration of prism exposure. Even after 100 trials of pointing through prisms, adaptation was incomplete, with participants continuing to exhibit a small rightward shift in both the reach endpoints and in the terminal phase of reach trajectories. Individual differences in the degree of adaptation of the terminal reach phase predicted the magnitude of prism after-effects. In summary, this study identifies distinct kinematic signatures of fast strategic versus slow sensorimotor realignment processes, which combine to adjust motor performance to compensate for a prismatic shift. © 2013 Elsevier Ltd. All rights reserved.
Seasonal control skylight glazing panel with passive solar energy switching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, J.V.
1983-10-25
A substantially transparent one-piece glazing panel is provided for generally horizontal mounting in a skylight. The panel is comprised of an repeated pattern of two alternating and contiguous linear optical elements; a first optical element being an upstanding generally right-triangular linear prism, and the second optical element being an upward-facing plano-cylindrical lens in which the planar surface is reflectively opaque and is generally in the same plane as the base of the triangular prism.
Surface plasmon resonance phenomenon of the insulating state polyaniline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Umiati, Ngurah Ayu Ketut, E-mail: ngurahayuketutumiati@gmail.com; Jurusan Fisika FMIPA Universitas Diponegoro, Jalan Prof. Soedarto, SH Tembalang Semarang 50275; Triyana, Kuwat
2015-04-16
Surface Plasmon Resonance (SPR) phenomenon of the insulating polyaniline (PANI) is has been observed. Surface Plasmon (SP) is the traveled electromagnetic wave that passes through the interface of dielectric metal and excited by attenuated total reflection (ATR) method in Kretschmannn configuration (Au-PANI prism). The resonance condition is observed through the angle of SPR in such condition that SP wave is coupled by the evanescent constant of laser beam. In this research, the laser beam was generated by He–Ne and its wavelength (λ) was 632,8 nm. SPR curve is obtained through observation of incidence angles of the laser beam in prism.more » SPR phenomenon at the boundary between Au – PANI layer has showed by reflection dip when the laser beam passes through the prism. In this early study, the observation was carried out through simulation Winspall 3.02 software and preliminary compared with some experimental data reported in other referred literatures. The results shows that the optimum layer of Au and polyaniline are 50 and 1,5 nm thick respectively. Our own near future experimental work would be further performed and reported elsewhere.« less
Occurrence of rhombic prisms in some structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyman, H.
1976-02-01
An ideal rhombic prism is defined as two regular trigonal prisms sharing a square face. In terms of such rhombic prisms, the structures of CrB and ..cap alpha..-PdCl/sub 2/, U/sub 3/Si/sub 2/ and Au/sub 3/Zn, and CoCa/sub 3/ and PdS are easily described. A network of rhombic prisms, with cubic symmetry, is also used to describe the structures of CoAs/sub 3/, Sc(OH)/sub 3/, WAl/sub 12/, and NaMn/sub 7/O/sub 12/.
Wollaston prism phase-stepping point diffraction interferometer and method
Rushford, Michael C.
2004-10-12
A Wollaston prism phase-stepping point diffraction interferometer for testing a test optic. The Wollaston prism shears light into reference and signal beams, and provides phase stepping at increased accuracy by translating the Wollaston prism in a lateral direction with respect to the optical path. The reference beam produced by the Wollaston prism is directed through a pinhole of a diaphragm to produce a perfect spherical reference wave. The spherical reference wave is recombined with the signal beam to produce an interference fringe pattern of greater accuracy.
Peripheral Prism Glasses: Effects of Dominance, Suppression and Background
Ross, Nicole C.; Bowers, Alex R.; Optom, M.C.; Peli, Eli
2012-01-01
Purpose Unilateral peripheral prisms for homonymous hemianopia (HH) place different images on corresponding peripheral retinal points, a rivalrous situation in which local suppression of the prism image could occur and thus limit device functionality. Detection with peripheral prisms has primarily been evaluated using conventional perimetry where binocular rivalry is unlikely to occur. We quantified detection over more visually complex backgrounds and examined the effects of ocular dominance. Methods Detection rates of 8 participants with HH or quadranopia and normal binocularity wearing unilateral peripheral prism glasses were determined for static perimetry targets briefly presented in the prism expansion area (in the blind hemifield) and the seeing hemifield, under monocular and binocular viewing, over uniform gray and more complex patterned backgrounds. Results Participants with normal binocularity had mixed sensory ocular dominance, demonstrated no difference in detection rates when prisms were fitted on the side of the HH or the opposite side (p>0.2), and had detection rates in the expansion area that were not different for monocular and binocular viewing over both backgrounds (p>0.4). However, two participants with abnormal binocularity and strong ocular dominance demonstrated reduced detection in the expansion area when prisms were fitted in front of the non-dominant eye. Conclusions We found little evidence of local suppression of the peripheral prism image for HH patients with normal binocularity. However, in cases of strong ocular dominance, consideration should be given to fitting prisms before the dominant eye. Although these results are promising, further testing in more realistic conditions including image motion is needed. PMID:22885783
Use of prism adaptation in children with unilateral brain lesion: Is it feasible?
Riquelme, Inmaculada; Henne, Camille; Flament, Benoit; Legrain, Valéry; Bleyenheuft, Yannick; Hatem, Samar M
2015-01-01
Unilateral visuospatial deficits have been observed in children with brain damage. While the effectiveness of prism adaptation for treating unilateral neglect in adult stroke patients has been demonstrated previously, the usefulness of prism adaptation in a pediatric population is still unknown. The present study aims at evaluating the feasibility of prism adaptation in children with unilateral brain lesion and comparing the validity of a game procedure designed for child-friendly paediatric intervention, with the ecological task used for prism adaptation in adult patients. Twenty-one children with unilateral brain lesion randomly were assigned to a prism group wearing prismatic glasses, or a control group wearing neutral glasses during a bimanual task intervention. All children performed two different bimanual tasks on randomly assigned consecutive days: ecological tasks or game tasks. The efficacy of prism adaptation was measured by assessing its after-effects with visual open loop pointing (visuoproprioceptive test) and subjective straight-ahead pointing (proprioceptive test). Game tasks and ecological tasks produced similar after-effects. Prismatic glasses elicited a significant shift of visuospatial coordinates which was not observed in the control group. Prism adaptation performed with game tasks seems an effective procedure to obtain after-effects in children with unilateral brain lesion. The usefulness of repetitive prism adaptation sessions as a therapeutic intervention in children with visuospatial deficits and/or neglect, should be investigated in future studies. Copyright © 2015 Elsevier Ltd. All rights reserved.
PRISM 3: expanded prediction of natural product chemical structures from microbial genomes.
Skinnider, Michael A; Merwin, Nishanth J; Johnston, Chad W; Magarvey, Nathan A
2017-07-03
Microbial natural products represent a rich resource of pharmaceutically and industrially important compounds. Genome sequencing has revealed that the majority of natural products remain undiscovered, and computational methods to connect biosynthetic gene clusters to their corresponding natural products therefore have the potential to revitalize natural product discovery. Previously, we described PRediction Informatics for Secondary Metabolomes (PRISM), a combinatorial approach to chemical structure prediction for genetically encoded nonribosomal peptides and type I and II polyketides. Here, we present a ground-up rewrite of the PRISM structure prediction algorithm to derive prediction of natural products arising from non-modular biosynthetic paradigms. Within this new version, PRISM 3, natural product scaffolds are modeled as chemical graphs, permitting structure prediction for aminocoumarins, antimetabolites, bisindoles and phosphonate natural products, and building upon the addition of ribosomally synthesized and post-translationally modified peptides. Further, with the addition of cluster detection for 11 new cluster types, PRISM 3 expands to detect 22 distinct natural product cluster types. Other major modifications to PRISM include improved sequence input and ORF detection, user-friendliness and output. Distribution of PRISM 3 over a 300-core server grid improves the speed and capacity of the web application. PRISM 3 is available at http://magarveylab.ca/prism/. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
[Prism correction in heterophoria].
Kommerell, G; Kromeier, M
2002-01-01
Unlike heterotropia (= manifest strabismus), heterophoria (= latent strabismus) is not a primarily existing condition but is a reaction to an interruption of the sensory-motor feedback control system. The reaction consists of a deviation from the orthovergence position. Binocular vision causes a continuous calibration of the vergence position. This "orthophorisation" explains that in most persons, heterophoria differs only slightly from zero. Nevertheless, a small heterophoria is common (70-80% of the population). The need to compensate for heterophoria by sensory-motor fusion can cause asthenopic complaints, such as headaches with prolonged reading. Since a variety of other defects can lead to similar symptoms, a causal relationship with heterophoria can be assumed only after a thorough differential diagnosis. Prism spectacles or eye muscle surgery for heterophoria should be recommended only after prism trials in free space, which include yoked prisms as a placebo control. Heterophoria should be distinguished from "Winkelfehlsichtigkeit", which is a deviation from orthoposition that results from the "measuring and correcting methodology after H.-J. Haase" (MKH) and is based on the idea that fixation disparity, a minute deviation from orthovergence position, indicates an inability to overcome a larger "vergence angle at rest". Objective recordings have, however, revealed that the subjective tests with stereo cues applied in the MKH can mislead to the assumption of a fixation disparity although both eyes are aligned exactly to the fixation point. A trial conducted in the Netherlands concerning the therapy of asthenopic complaints showed no statistically significant advantage of prism spectacles determined with the MKH over conventional spectacles.
NASA Astrophysics Data System (ADS)
Flemings, Peter B.; Saffer, Demian M.
2018-02-01
We predict pressure and stress from porosity in the Nankai accretionary prism with a critical state soil model that describes porosity as a function of mean stress and maximum shear stress, and assumes Coulomb failure within the wedge and uniaxial burial beneath it. At Ocean Drilling Program Sites 1174 and 808, we find that pore pressure in the prism supports 70% to 90% of the overburden (λu = 0.7 to 0.9), for a range of assumed friction angles (5-30°). The prism pore pressure is equal to or greater than that in the underthrust sediments even though the porosity is lower within the prism. The high pore pressures lead to a mechanically weak wedge that supports low maximum shear stress, and this in turn requires very low basal traction to remain consistent with the observed narrowly tapered wedge geometry. We estimate the décollement friction coefficient (μb) to be 0.08-0.38 (ϕb' = 4.6°-21°). Our approach defines a pathway to predict pressure in a wide range of environments from readily observed quantities (e.g., porosity and seismic velocity). Pressure and stress control the form of the Earth's collisional continental margins and play a key role in its greatest earthquakes. However, heretofore, there has been no systematic approach to relate material state (e.g., porosity), pore pressure, and stress in these systems.
NASA Technical Reports Server (NTRS)
Breckinridge, J. B.; Page, N. A.; Rodgers, J. M.
1985-01-01
Efficient linear dispersive element for spectrometer instruments achieved using several different glasses in multiple-element prism. Good results obtained in both two-and three-element prisms using variety of different glass materials.
Goedert, Kelly M; Chen, Peii; Foundas, Anne L; Barrett, A M
2018-03-20
Spatial neglect commonly follows right hemisphere stroke. It is defined as impaired contralesional stimulus detection, response, or action, causing functional disability. While prism adaptation treatment is highly promising to promote functional recovery of spatial neglect, not all individuals respond. Consistent with a primary effect of prism adaptation on spatial movements, we previously demonstrated that functional improvement after prism adaptation treatment is linked to frontal lobe lesions. However, that study was a treatment-only study with no randomised control group. The current study randomised individuals with spatial neglect to receive 10 days of prism adaptation treatment or to receive only standard care (control group). Replicating our earlier results, we found that the presence of frontal lesions moderated response to prism adaptation treatment: among prism-treated patients, only those with frontal lesions demonstrated functional improvements in their neglect symptoms. Conversely, among individuals in the standard care control group, the presence of frontal lesions did not modify recovery. These results suggest that further research is needed on how frontal lesions may predict response to prism adaptation treatment. Additionally, the results help elucidate the neural network involved in spatial movement and could be used to aid decisions about treatment.
NASA Astrophysics Data System (ADS)
Jurado, Maria Jose; Schleicher, Anja
2015-04-01
Our research focused on the characterization of fracture and fault structures from the deep Nankai Trough accretionary prism in Japan. Logging Data and cuttings samples from the two most recent International Ocean Discovery Program (IODP) Expeditions 338 and 348 of the NanTroSEIZE project were analyzed by Logging While Drilling (LWD) oriented images, geophysical logs and clay mineralogy. Both expeditions took place at Site C0002, but whereas Hole C0002F (Expedition 338) was drilled down to 2004.5 mbsf, Hole C0002N and C0002P (Expedition 348) reached a depth of 2325.5 mbsf and 3058.8 mbsf respectively. The structural interpretation of borehole imaging data illustrates the deformation within the fractured and faulted sections of the accretionary prism. All drill holes show distinct areas of intense fracturing and faulting within a very clay-dominated lithology. Here, smectite and illite are the most common clay minerals, but the properties and the role they may play in influencing the fractures, faults and folds in the accretionary prism is still not well understood. When comparing clay mineralogy and fracture/fault areas in hole C0002F (Expedition 338), a trend in the abundance of illite and smectite, and in particular the swelling behavior of smectite is recognizable. In general, the log data provided a good correlation with the actual mineralogy and the relative abundance of clay. Ongoing postcruise preliminary research on hole C0002 N and C0002P (Expedition 348) should confirm these results. The relationship between fracture and fault structures and the changes in clay mineralogy could be explained by the deformation of specific areas with different compaction features, fluid-rock interaction processes, but could also be related to beginning diagenetic processes related to depth. Our results show the integration of logging data and cutting sample analyses as a valuable tool for characterization of petrophysical and mineralogical changes of the structures of the Nankai accretionary prism. This is critical for our understanding of clay-fluid interaction and mechanical properties duing fault displacements and seismogenesis.
NASA Astrophysics Data System (ADS)
Tobin, H. J.; Hirose, T.; Saffer, D. M.; Toczko, S.; Maeda, L.
2014-12-01
International Ocean Discovery Program (IODP) Expedition 348, the latest advance of the NanTroSEIZE project, started on 13 September 2013 and was completed on 29 January 2014. During Expedition 348, the drilling vessel Chikyu advanced the ultra-deep riser hole at Site C0002, located 80 km offshore of the Kii Peninsula, from a depth of 860 meters below sea floor (mbsf) to 3058.5 mbsf, the world record for the deepest scientific ocean drilling, and cased it for future deepening. The drilling operation successfully obtained data on formation physical properties from logging while drilling (LWD) tools, as well as from lithological analyses of cuttings and core from the interior of the active accretionary prism at the Nankai Trough. IODP Site C0002 is the currently only borehole to access the deep interior of an active convergent margin. Preliminary scientific results of Expedition 348 are as follows: (1) Fine-grained turbiditic mudstones with coarser silty and sandy interbeds, exhibiting steep dips (between ~60 and 90 degrees) are predominant in the prism down to ~3000 mbsf. The biostratigraphic age of the sediments in the lowermost part of the hole is thought to be 9-11 Ma, with an assumed age of accretion of 3-5 Ma. (2) Slickenlined surfaces, deformation bands and mineral veins are present throughout the drilled interval, while well-developed scaly clay fabrics are increasingly observed below ~2200 mbsf. A substantial fault zone with well-developed foliation was successfully cored from the deep interior of the prism at ~2205 mbsf. (3) Porosity generally decreases from ~60% to ~20% from the seafloor to 3000 mbsf. However, physical properties including grain density, electrical conductivity and P-wave velocity suggest fairly homogeneous properties in the interior of the prism between ~2000 and 3000 mbsf. (4) Mud gas analysis during the riser drilling indicates that a source of methane gas shifts from microbial origin to thermogenic at around 2325 mbsf. (5) The maximum horizontal principal stress at ~2200 mbsf is in the NE-SW direction. The inner wedge at ~ 2000 mbsf is currently in a strike-slip stress regime.
Hill, R.J.; Schenk, C.J.
2005-01-01
Petroleum produced from the Barbados accretionary prism (at Woodbourne Field on Barbados) is interpreted as generated from Cretaceous marine shale deposited under normal salinity and dysoxic conditions rather than from a Tertiary source rock as previously proposed. Barbados oils correlate with some oils from eastern Venezuela and Trinidad that are positively correlated to extracts from Upper Cretaceous La Luna-like source rocks. Three distinct groups of Barbados oils are recognized based on thermal maturity, suggesting petroleum generation occurred at multiple levels within the Barbados accretionary prism. Biodegradation is the most significant process affecting Barbados oils resulting in increased sulfur content and decreased API gravity. Barbados gases are interpreted as thermogenic, having been co-generated with oil, and show mixing with biogenic gas is limited. Gas biodegradation occurred in two samples collected from shallow reservoirs at the Woodbourne Field. The presence of Cretaceous source rocks within the Barbados accretionary prism suggests that greater petroleum potential exists regionally, and perhaps further southeast along the passive margin of South America. Likewise, confirmation of a Cretaceous source rock indicates petroleum potential exists within the Barbados accretionary prism in reservoirs that are deeper than those from Woodbourne Field.
Rhomboid prism pair for rotating the plane of parallel light beams
NASA Technical Reports Server (NTRS)
Orloff, K. L. (Inventor); Yanagita, H.
1982-01-01
An optical system is described for rotating the plane defined by a pair of parallel light beams. In one embodiment a single pair of rhomboid prisms have their respective input faces disposed to receive the respective input beams. Each prism is rotated about an axis of revolution coaxial with each of the respective input beams by means of a suitable motor and gear arrangement to cause the plane of the parallel output beams to be rotated relative to the plane of the input beams. In a second embodiment, two pairs of rhomboid prisms are provided. In a first angular orientation of the output beams, the prisms merely decrease the lateral displacement of the output beams in order to keep in the same plane as the input beams. In a second angular orientation of the prisms, the input faces of the second pair of prisms are brought into coincidence with the input beams for rotating the plane of the output beams by a substantial angle such as 90 deg.
Jayapandian, Catherine P; Chen, Chien-Hung; Bozorgi, Alireza; Lhatoo, Samden D; Zhang, Guo-Qiang; Sahoo, Satya S
2013-01-01
Epilepsy is the most common serious neurological disorder affecting 50-60 million persons worldwide. Electrophysiological data recordings, such as electroencephalogram (EEG), are the gold standard for diagnosis and pre-surgical evaluation in epilepsy patients. The increasing trend towards multi-center clinical studies require signal visualization and analysis tools to support real time interaction with signal data in a collaborative environment, which cannot be supported by traditional desktop-based standalone applications. As part of the Prevention and Risk Identification of SUDEP Mortality (PRISM) project, we have developed a Web-based electrophysiology data visualization and analysis platform called Cloudwave using highly scalable open source cloud computing infrastructure. Cloudwave is integrated with the PRISM patient cohort identification tool called MEDCIS (Multi-modality Epilepsy Data Capture and Integration System). The Epilepsy and Seizure Ontology (EpSO) underpins both Cloudwave and MEDCIS to support query composition and result retrieval. Cloudwave is being used by clinicians and research staff at the University Hospital - Case Medical Center (UH-CMC) Epilepsy Monitoring Unit (EMU) and will be progressively deployed at four EMUs in the United States and the United Kingdomas part of the PRISM project.
Shearing interference microscope for step-height measurements.
Trịnh, Hưng-Xuân; Lin, Shyh-Tsong; Chen, Liang-Chia; Yeh, Sheng-Lih; Chen, Chin-Sheng; Hoang, Hong-Hai
2017-05-01
A shearing interference microscope using a Savart prism as the shear plate is proposed for inspecting step-heights. Where the light beam propagates through the Savart prism and microscopic system to illuminate the sample, it then turns back to re-pass through the Savart prism and microscopic system to generate a shearing interference pattern on the camera. Two measurement modes, phase-shifting and phase-scanning, can be utilized to determine the depths of the step-heights on the sample. The first mode, which employs a narrowband source, is based on the five-step phase-shifting algorithm and has a measurement range of a quarter-wavelength. The second mode, which adopts a broadband source, is based on peak-intensity identification technology and has a measurement range up to a few micrometres. This paper is to introduce the configuration and measurement theory of this microscope, perform a setup used to implement it, and present the experimental results from the uses of the setup. The results not only verify the validity but also confirm the high measurement repeatability of the proposed microscope. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
Designing and researching of the virtual display system based on the prism elements
NASA Astrophysics Data System (ADS)
Vasilev, V. N.; Grimm, V. A.; Romanova, G. E.; Smirnov, S. A.; Bakholdin, A. V.; Grishina, N. Y.
2014-05-01
Problems of designing of systems for virtual display systems for augmented reality placed near the observers eye (so called head worn displays) with the light guide prismatic elements are considered. Systems of augmented reality is the complex consists of the image generator (most often it's the microdisplay with the illumination system if the display is not self-luminous), the objective which forms the display image practically in infinity and the combiner which organizes the light splitting so that an observer could see the information of the microdisplay and the surrounding environment as the background at the same time. This work deals with the system with the combiner based on the composite structure of the prism elements. In the work three cases of the prism combiner design are considered and also the results of the modeling with the optical design software are presented. In the model the question of the large pupil zone was analyzed and also the discontinuous character (mosaic structure) of the angular field in transmission of the information from the microdisplay to the observer's eye with the prismatic structure are discussed.
Device for magneto-optic signal detection with a small crystal prism.
Saito, K; Sato, S; Shino, K; Taniguchi, T
2000-03-10
A device made of a birefringent crystal for signal detection of magneto-optic (MO) disks is presented. The light beam from a MO disk is separated into two orthogonally polarized components at the surface of a birefringent prism. After these two components are reflected by the top and the bottom surfaces of the prism inside, at the detector they become sufficiently separated from each other for discrete detection, even though the prism is small. A method for calculating the light intensities and the positions of focused beams in a birefringent prism and the results of a fundamental experiment are presented.
Barbados: Architecture and implications for accretion
NASA Astrophysics Data System (ADS)
Speed, R. C.; Larue, D. K.
1982-05-01
The island of Barbados exposes the crestal zone of the remarkably broad accretionary prism of the Lesser Antilles foreacrc. The architecture of Barbados is three-tiered: an upper arched cap of Pleistocene reefs that record rapid and differential uplift of the island, an intermediate zone of nappes of mainly abyssal or deep bathyal pelagic rocks, and a basal complex whose lithotypes extend to substantial depth and may be representative of the bulk of the western or inner accretionary prism. The exposed basal complex consists of generally steeply dipping ENE to NE-striking fault-bounded packets which contain rocks of one of three lithic suites: terrigenous (quartzose turbidite and mudstone), debris flow, and hemipelagic (chiefly radiolarite). Present but imcomplete rock dating indicates that the terrigenous and hemipelagic suites and the pelagic rocks of the intermediate zone are age overlapping in Early and Middle Eocene time. Deformation within packets of the basal complex is systematic, pre- or synfault, and indicative of shortening that is generally normal to packet boundaries. A unit of terrigenous materials that probably underwent local resedimentation in the Miocene is recognized in wells, but its relationship to exposed rocks is uncertain. The packet-bounding faults of the basal complex are interpreted to have been primary accretionary surfaces which may have been reactivated by later intraprism movements. Exposed sedimentary rocks of Barbados can be successfully assigned to contemporaneous depositional sites associated with an accretionary prism: terrigenous beds to a trench wedge that was connected to South American sediment sources, debris flow to trench floor or slope basin accumulations of material derived from the lower slope, hemipelagic to Atlantic plain strata, and pelagic rocks of the intermediate zone to deep outer forearc basin sites. The decollement at the base of the intermediate zone is probably due to uplift and arcward motion of the crestal zone of the accretionary prism with respect to the forearc basin during progressive prism growth. Principal uplift of the prism seems to have started, apparently abruptly, in the Miocene. Quaternary uplift of Barbados may be due partly to local diapirism. Paleogene subduction that created the arcward region of the prism probably occurred in a differently configured zone from the present one.
NASA Astrophysics Data System (ADS)
Smith, G. L.; McNeill, L. C.; Henstock, T.; Bull, J. M.
2011-12-01
The Makran subduction zone is the widest accretionary prism in the world (~400km), generated by convergence between the Arabian and Eurasian tectonic plates. It represents a global end-member, with a 7km thick incoming sediment section. Accretionary prisms have traditionally been thought to be aseismic due to the presence of unconsolidated sediment and elevated basal pore pressures. The seismogenic potential of the Makran subduction zone is unclear, despite a Mw 8.1 earthquake in 1945 that may have been located on the plate boundary beneath the prism. In this study, a series of imbricate landward dipping (seaward verging) thrust faults have been interpreted across the submarine prism (outer 70 km) using over 6000km of industry multichannel seismic data and bathymetric data. A strong BSR (bottom simulating reflector) is present throughout the prism (excluding the far east). An unreflective décollement is interpreted from the geometry of the prism thrusts. Two major sedimentary units are identified in the input section, the lower of which contains the extension of the unreflective décollement surface. Between 60%-100% of the input section is currently being accreted. The geometry of piggy-back basin stratigraphy shows that the majority of thrusts, including those over 50km from the trench, are recently active. Landward thrusts show evidence for reactivation after periods of quiescence. Negative polarity fault plane reflectors are common in the frontal thrusts and in the eastern prism, where they may be related to increased fault activity and fluid expulsion, and are rarer in older landward thrusts. Significant NE-SW trending basement structures (The Murray Ridge and Little Murray Ridge) on the Arabian plate intersect the deformation front and affect sediment input to the subduction zone. Prism taper and structure are apparently primarily controlled by sediment supply and the secondary influence of subducting basement ridges. The thick, likely distal, sediment section in the west produces a prism with a simple imbricate structure. As basement depth is reduced over the Little Murray Ridge, the accretionary prism structure (fault spacing and deformation front position) changes. In the east, proximity to the Murray Ridge and triple junction is expressed through a reduction in prism width and reduced fault activity. The resulting prism structure and morphology can ultimately be used to assess likely sediment properties and hence seismic potential at the plate boundary.
Transforming White Light into Rainbows: Segmentation Strategies for Successful School Tax Elections
ERIC Educational Resources Information Center
Senden, J. Bradford; Lifto, Don E.
2009-01-01
In the late 1600s, British physicist Sir Isaac Newton first demonstrated refraction and dispersion in a triangular prism. He discovered that a prism could decompose white light into a spectrum. Hold a prism up to the light at the correct angle and white light magically splits into vivid colors of the rainbow! So what do prisms and rainbows have to…
Do dissociated or associated phoria predict the comfortable prism?
Otto, Joanna M. N.; Kromeier, Miriam; Bach, Michael
2008-01-01
Background Dissociated and associated phoria are measures of latent strabismus under artificial viewing conditions. We examined to what extent dissociated and associated phoria predict the “comfortable prism”, i.e. the prism that appears most comfortable under natural viewing conditions. Methods For associated phoria, a configuration resembling the Mallett test was employed: both eyes were presented with a fixation cross, surrounded by fusionable objects. Nonius lines served as monocular markers. For dissociated phoria, the left eye was presented with all the Mallett elements, while only a white spot was presented to the right eye. To determine the comfortable prism, all the Mallett elements, including the Nonius lines, were shown to both eyes. In each of the three tests, the observer had to adjust a pair of counterrotating prisms. To avoid any (possibly prejudiced) influence of the experimenter, the prismatic power was recorded with a potentiometer. Twenty non-strabismic subjects with a visual acuity of ≥1.0 in each eye were examined. Results The range of the intertrial mean was for dissociated phoria from +9.3 eso to −5.9 cm/m exo, for associated phoria from +11.2 eso to −3.3 cm/m exo, and for the comfortable prism from +4.8 eso to −4.1 cm/m exo (cm/m = prism dioptre). In most observers, the phoria parameters differed greatly from the comfortable prism. On average, the phoria values were shifted about 2 cm/m towards the eso direction in relation to the comfortable prism (associated phoria not less than dissociated phoria). Conclusions The deviation of both, dissociated and associated phoria, from the comfortable prism suggests that the abnormal viewing conditions under which the phoria parameters are determined induce artefacts. Accordingly, the findings cast doubt on current textbook recommendations to use dissociated or associated phoria as a basis for therapeutic prisms. Rather, patients should be allowed to determine their comfortable prism under natural viewing conditions. PMID:18379816
Prism adaptation does not alter configural processing of faces
Bultitude, Janet H.; Downing, Paul E.; Rafal, Robert D.
2013-01-01
Patients with hemispatial neglect (‘neglect’) following a brain lesion show difficulty responding or orienting to objects and events on the left side of space. Substantial evidence supports the use of a sensorimotor training technique called prism adaptation as a treatment for neglect. Reaching for visual targets viewed through prismatic lenses that induce a rightward shift in the visual image results in a leftward recalibration of reaching movements that is accompanied by a reduction of symptoms in patients with neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Interestingly, prism adaptation can also alter aspects of non-lateralised spatial attention. We previously demonstrated that prism adaptation alters the extent to which neglect patients and healthy participants process local features versus global configurations of visual stimuli. Since deficits in non-lateralised spatial attention are thought to contribute to the severity of neglect symptoms, it is possible that the effect of prism adaptation on these deficits contributes to its efficacy. This study examines the pervasiveness of the effects of prism adaptation on perception by examining the effect of prism adaptation on configural face processing using a composite face task. The composite face task is a persuasive demonstration of the automatic global-level processing of faces: the top and bottom halves of two familiar faces form a seemingly new, unknown face when viewed together. Participants identified the top or bottom halves of composite faces before and after prism adaptation. Sensorimotor adaptation was confirmed by significant pointing aftereffect, however there was no significant change in the extent to which the irrelevant face half interfered with processing. The results support the proposal that the therapeutic effects of prism adaptation are limited to dorsal stream processing. PMID:25110574
Ajtony, Csilla; Elkarmouty, Ahmed; Barton, Keith; Kotecha, Aachal
2016-06-01
To evaluate the levels of agreement between the standard reusable prism and a disposable prism, and to examine the agreement between ophthalmologists, nursing and technical staff when measuring intraocular pressure (IOP) using the Goldmann applanation tonometer. Three hundred eyes of 300 patients were recruited. IOP measurements were made in a randomised order by three observer groups consisting of ophthalmologists and ophthalmic technicians/nurses taken from a pool of clinicians working within a busy outpatient clinic. Agreement was calculated by Bland-Altman analysis, showing the mean difference and 95% limits of agreement (LoA) of measurements. The mean difference between the reusable and disposable prism IOP measurements was <0.5 mm Hg. The LoA ranged from ±3.1 to ±4.9 mm Hg, depending on the observer group. The interobserver variability was <1 mm Hg across all observer groups; the LoA was slightly higher for observers using the reusable prism (range between ±4.3 and ±5.6 mm Hg) compared with using the disposable prism (range between ±3.7 and ±5.4 mm Hg) across observer groups. There is an acceptable agreement between IOP measurements made with the reusable Goldmann tonometer prism and the disposable Tonosafe prism. Interobserver variability in IOP measurements within an outpatient setting is larger than that found within a research setting, and may be of a level that impacts on clinical decision-making. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Prism adaptation does not alter configural processing of faces.
Bultitude, Janet H; Downing, Paul E; Rafal, Robert D
2013-01-01
Patients with hemispatial neglect ('neglect') following a brain lesion show difficulty responding or orienting to objects and events on the left side of space. Substantial evidence supports the use of a sensorimotor training technique called prism adaptation as a treatment for neglect. Reaching for visual targets viewed through prismatic lenses that induce a rightward shift in the visual image results in a leftward recalibration of reaching movements that is accompanied by a reduction of symptoms in patients with neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Interestingly, prism adaptation can also alter aspects of non-lateralised spatial attention. We previously demonstrated that prism adaptation alters the extent to which neglect patients and healthy participants process local features versus global configurations of visual stimuli. Since deficits in non-lateralised spatial attention are thought to contribute to the severity of neglect symptoms, it is possible that the effect of prism adaptation on these deficits contributes to its efficacy. This study examines the pervasiveness of the effects of prism adaptation on perception by examining the effect of prism adaptation on configural face processing using a composite face task. The composite face task is a persuasive demonstration of the automatic global-level processing of faces: the top and bottom halves of two familiar faces form a seemingly new, unknown face when viewed together. Participants identified the top or bottom halves of composite faces before and after prism adaptation. Sensorimotor adaptation was confirmed by significant pointing aftereffect, however there was no significant change in the extent to which the irrelevant face half interfered with processing. The results support the proposal that the therapeutic effects of prism adaptation are limited to dorsal stream processing.
PRISM3 DOT1 Atlantic Basin Reconstruction
Dowsett, Harry; Robinson, Marci; Dwyer, Gary S.; Chandler, Mark; Cronin, Thomas
2006-01-01
PRISM3 DOT1 (Pliocene Research, Interpretation and Synoptic Mapping 3, Deep Ocean Temperature 1) provides a three-dimensional temperature reconstruction for the mid-Pliocene Atlantic basin, the first of several regional data sets that will comprise a global mid-Pliocene reconstruction. DOT1 is an alteration of modern temperature values for the Atlantic Ocean in 4 degree x 5 degree cells in 13 depth layers for December 1 based on Mg/Ca-derived BWT estimates from seventeen DSDP and ODP Sites and SST estimates from the PRISM2 reconstruction (Dowsett et al., 1999). DOT1 reflects a vaguely modern circulation system, assuming similar processes of deep-water formation; however, North Atlantic Deep Water (NADW) production is increased, and Antarctic Bottom Water (AABW) production is decreased. Pliocene NADW was approximately 2 degreesC warmer than modern temperatures, and Pliocene AABW was approximately 0.3 degreesC warmer than modern temperatures.
NASA Astrophysics Data System (ADS)
Lan, Guoqiang; Liu, Shugang; Wang, Yuxiao; Zhang, Xueru; Song, Yinglin
2015-10-01
In this work, we use the liquid-prism SPR sensing configuration to determine the chromatic dispersion of different liquids, since the condition of SPR is sensitive to the refractive index of the liquid prism. We use the glass slide coated with 50 nm Au film as the sensing chip, and use AvaLight - HAL (360 nm - 2500 nm) light source as the broaden band light source in our experiments. We adopt the deionized water as the standard sample to determine the chromatic dispersion of different liquid samples (ethanol and n-hexane), and we implement the experiment through the SPR sensing configuration in angular and spectral interrogations. According to the experimental data, the chromatic dispersions of ethanol and n-hexane are obtained. The proposed technique provides a new high sensitive method for the determination of chromatic dispersion of liquids.
Baba, Justin S.
2015-11-24
Refractometers for simultaneously measuring refractive index of a sample over a range or wavelengths of light include dispersive and focusing optical systems. An optical beam including the rang of wavelengths is spectrally spread along a first axis and focused along a second axis so as to be incident to an interface between the sample and a prism at a range of angles of incidence including a critical angle for at least one wavelength. In some cases, the prism can have a triangle, parallelogram, trapezoid, or other shape. In some cases, the optical beam can be reflected off of multiple interfaces between the prism and the sample. An imaging detector is situated to receive the spectrally spread and focused light from the interface and form an image corresponding to angle of incidence as a function of wavelength. One or more critical angles are indentified and corresponding refractive indices are determined.
Code of Federal Regulations, 2013 CFR
2013-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2014 CFR
2014-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2014 CFR
2014-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2012 CFR
2012-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2012 CFR
2012-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2013 CFR
2013-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Design of direct-vision cyclo-olefin-polymer double Amici prism for spectral imaging.
Wang, Lei; Shao, Zhengzheng; Tang, Wusheng; Liu, Jiying; Nie, Qianwen; Jia, Hui; Dai, Suian; Zhu, Jubo; Li, Xiujian
2017-10-20
A direct-vision Amici prism is a desired dispersion element in the value of spectrometers and spectral imaging systems. In this paper, we focus on designing a direct-vision cyclo-olefin-polymer double Amici prism for spectral imaging systems. We illustrate a designed structure: E48R/N-SF4/E48R, from which we obtain 13 deg dispersion across the visible spectrum, which is equivalent to 700 line pairs/mm grating. We construct a simulative spectral imaging system with the designed direct-vision cyclo-olefin-polymer double Amici prism in optical design software and compare its imaging performance to a glass double Amici prism in the same system. The results of spot-size RMS demonstrate that the plastic prism can serve as well as their glass competitors and have better spectral resolution.
Modeling laser brightness from cross Porro prism resonators
NASA Astrophysics Data System (ADS)
Forbes, Andrew; Burger, Liesl; Litvin, Igor Anatolievich
2006-08-01
Laser brightness is a parameter often used to compare high power laser beam delivery from various sources, and incorporates both the power contained in the particular mode, as well as the propagation of that mode through the beam quality factor, M2. In this study a cross Porro prism resonator is considered; crossed Porro prism resonators have been known for some time, but until recently have not been modeled as a complete physical optics system that allows the modal output to be determined as a function of the rotation angle of the prisms. In this paper we consider the diffraction losses as a function of the prism rotation angle relative to one another, and combine this with the propagation of the specific modes to determine the laser output brightness as a function of the prism orientation.
Jones, Jeanne; Kalkan, Erol; Stephens, Christopher
2017-02-23
A continually increasing number of high-quality digital strong-motion records from stations of the National Strong-Motion Project (NSMP) of the U.S. Geological Survey (USGS), as well as data from regional seismic networks within the United States, call for automated processing of strong-motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong-motion records. When used without AQMS, PRISM provides batch-processing capabilities. The PRISM version 1.0.0 is platform independent (coded in Java), open source, and does not depend on any closed-source or proprietary software. The software consists of two major components: a record processing engine and a review tool that has a graphical user interface (GUI) to manually review, edit, and process records. To facilitate use by non-NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand-alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible in order to accommodate new processing techniques. This report provides a thorough description and examples of the record processing features supported by PRISM. All the computing features of PRISM have been thoroughly tested.
Saj, Arnaud; Cojan, Yann; Vocat, Roland; Luauté, Jacques; Vuilleumier, Patrik
2013-01-01
Unilateral spatial neglect involves a failure to report or orient to stimuli in the contralesional (left) space due to right brain damage, with severe handicap in everyday activities and poor rehabilitation outcome. Because behavioral studies suggest that prism adaptation may reduce spatial neglect, we investigated the neural mechanisms underlying prism effects on visuo-spatial processing in neglect patients. We used functional magnetic resonance imaging (fMRI) to examine the effect of (right-deviating) prisms on seven patients with left neglect, by comparing brain activity while they performed three different spatial tasks on the same visual stimuli (bisection, search, and memory), before and after a single prism-adaptation session. Following prism adaptation, fMRI data showed increased activation in bilateral parietal, frontal, and occipital cortex during bisection and visual search, but not during the memory task. These increases were associated with significant behavioral improvement in the same two tasks. Changes in neural activity and behavior were seen only after prism adaptation, but not attributable to mere task repetition. These results show for the first time the neural substrates underlying the therapeutic benefits of prism adaptation, and demonstrate that visuo-motor adaptation induced by prism exposure can restore activation in bilateral brain networks controlling spatial attention and awareness. This bilateral recruitment of fronto-parietal networks may counteract the pathological biases produced by unilateral right hemisphere damage, consistent with recent proposals that neglect may reflect lateralized deficits induced by bilateral hemispheric dysfunction. Copyright © 2011 Elsevier Ltd. All rights reserved.
Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
Shi, Tujin; Sun, Xuefei; Gao, Yuqian; Fillmore, Thomas L.; Schepmoes, Athena A.; Zhao, Rui; He, Jintang; Moore, Ronald J.; Kagan, Jacob; Rodland, Karin D.; Liu, Tao; Liu, Alvin Y.; Smith, Richard D.; Tang, Keqi; Camp, David G.; Qian, Wei-Jun
2013-01-01
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50–100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion. Limits of quantification (LOQ) at low ng/mL levels with a median coefficient of variation (CV) of ~12% were achieved for proteins spiked into human female serum. PRISM-SRM provided >100-fold improvement in the LOQ when compared to conventional LC-SRM measurements. PRISM-SRM was then applied to measure several low-abundance endogenous serum proteins, including prostate-specific antigen (PSA), in clinical prostate cancer patient sera. PRISM-SRM enabled confident detection of all target endogenous serum proteins except the low pg/mL-level cardiac troponin T. A correlation coefficient >0.99 was observed for PSA between the results from PRISM-SRM and immunoassays. Our results demonstrate that PRISM-SRM can successful quantify low ng/mL proteins in human plasma or serum without depletion. We anticipate broad applications for PRISM-SRM quantification of low-abundance proteins in candidate biomarker verification and systems biology studies. PMID:23763644
NASA Astrophysics Data System (ADS)
Chester, F. M.
2013-12-01
The Japan Trench convergent margin produces frequent large interplate earthquakes greater than M7.5, and is known to display the primary characteristics of non-accretionary margins. The 2011 Mw 9.0 Tohoku-oki earthquake demonstrates the capability of this margin to rupture the full extent of the seismogenic zone and up-dip to the trench axis in a single great event. A variety of observations indicate that the slip magnitude of this rupture increased towards the trench, with 50+ m of slip occurring at the ~20-km-wide frontal prism of accreted sediments and lower trench slope. IODP expedition 343/343T (JFAST) was designed to address fundamental questions of earthquake physics through rapid-response drilling, but also provides new information on sediment accretion and the architecture of the frontal prism. The JFAST drill site is located above a horst block in the subducting plate and 6 km landward from the trench axis; three boreholes were drilled through the prism and across the plate-boundary. Palinspastic reconstruction of the prism structure based on a seismic line through the drill site, logging data, and lithologic and structural observations of core samples document a single dominant décollement that accommodated almost all of the interplate displacement (~3.2 km) at the drill site. The décollement is located in pelagic clay near the base of the incoming sediment section of the subducting plate, and maintains this stratigraphic position trenchward until it enters the graben below the trench axis where it cuts down-section to follow the basal strata. The structure indicates about half the incoming sediment is offscraped onto the leading edge of the prism but similar amount of sediment may be removed from the base of the frontal prism associated with progressive amplification of horsts and grabens more landward below the prism. The localization of nearly all the interplate displacement to a single narrow décollement composed of sheared pelagic clay indicates the décollement is relatively weak over geologic time. Borehole measurements of temperature across the plate boundary confirm the Tohoku earthquake ruptured the décollement and, consistent with results of high-speed friction experiments on sheared clay, that the décollement is extremely weak during seismic slip. These results, combined with borehole data indicating that the current in situ stress is approximately lithostatic, support the hypothesis that dynamic weakening of wet clay at seismic slip rates favor earthquake rupture propagation to shallow depths even though the frictional properties of wet clay at low slip rates prohibit the nucleation of slip instabilities. Core samples of sheared clay from the décollement are being analyzed to identify earthquake-related microstructures and determine the mechanisms of dynamic weakening during seismic slip.
User’s Guide Engineering Data Compendium Human Perception and Performance
1988-01-01
covered (CRef. 1.222) by large wedges of sound-absorbing material to minimize Achromatic. (1) Characterized by an absence of chroma reflections and...walk model. A model of the perception and Risley prism. A prism assembly comprised of two thin decision response components in reaction time tasks... wedge prisms (generally identical) arranged in series. According to the model, an ideal detector accumulates Rotating the two prisms in opposite
Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface.
McCafferty, Sean; Lim, Garrett; Duncan, William; Enikov, Eniko; Schwiegerling, Jim
2016-09-01
We evaluate solutions for an applanating surface modification to the Goldmann tonometer prism, which substantially negates the errors due to patient variability in biomechanics. A modified Goldmann or correcting applanation tonometry surface (CATS) prism is presented which was optimized to minimize the intraocular pressure (IOP) error due to corneal thickness, stiffness, curvature, and tear film. Mathematical modeling with finite element analysis (FEA) and manometric IOP referenced cadaver eyes were used to optimize and validate the design. Mathematical modeling of the optimized CATS prism indicates an approximate 50% reduction in each of the corneal biomechanical and tear film errors. Manometric IOP referenced pressure in cadaveric eyes demonstrates substantial equivalence to GAT in nominal eyes with the CATS prism as predicted by modeling theory. A CATS modified Goldmann prism is theoretically able to significantly improve the accuracy of IOP measurement without changing Goldmann measurement technique or interpretation. Clinical validation is needed but the analysis indicates a reduction in CCT error alone to less than ±2 mm Hg using the CATS prism in 100% of a standard population compared to only 54% less than ±2 mm Hg error with the present Goldmann prism. This article presents an easily adopted novel approach and critical design parameters to improve the accuracy of a Goldmann applanating tonometer.
NASA Astrophysics Data System (ADS)
Agrawal, L.; Bhardwaj, A.; Pal, S.; Kumar, A.
2007-11-01
This article presents the results of a detailed theoretical and experimental analysis carried out on a folded Z-shaped polarization coupled, electro-optically Q-switched laser resonator with Porro prisms and waveplates. The advantages of adding waveplates in a Porro prism resonator have been explored for creating high loss condition prior to Q-switching and obtaining variable reflectivity with fixed orientation of Porro prism. Generalized expressions have been derived in terms of azimuth angles and phase shifts introduced by the polarizing elements. These expressions corroborate with known reported results under appropriate substitutions. A specific case of a crossed Porro prism diode-pumped Nd:YAG laser has been theoretically and experimentally investigated. In the feedback arm, a 0.57λ waveplate oriented at 135° completely compensates the phase shift of a fused silica Porro prism and provides better tolerances than a BK-7 prism/0.60λ waveplate combination to stop prelasing. The fused silica prism/0.57λ combination with waveplate at 112° acts like a 100% mirror and was utilized for optimization of free running performance. The effective reflectivity was determined for various orientations of the quarter waveplate in the gain arm to numerically estimate the Q-switched laser pulse parameters through rate equation analysis. Experimental results match well with the theoretical analysis.
Accuracy assessment of ALOS optical instruments: PRISM and AVNIR-2
NASA Astrophysics Data System (ADS)
Tadono, Takeo; Shimada, Masanobu; Iwata, Takanori; Takaku, Junichi; Kawamoto, Sachi
2017-11-01
This paper describes the updated results of calibration and validation to assess the accuracies for optical instruments onboard the Advanced Land Observing Satellite (ALOS, nicknamed "Daichi"), which was successfully launched on January 24th, 2006 and it is continuously operating very well. ALOS has an L-band Synthetic Aperture Radar called PALSAR and two optical instruments i.e. the Panchromatic Remotesensing Instrument for Stereo Mapping (PRISM) and the Advanced Visible and Near Infrared Radiometer type-2 (AVNIR-2). PRISM consists of three radiometers and is used to derive a digital surface model (DSM) with high spatial resolution that is an objective of the ALOS mission. Therefore, geometric calibration is important in generating a precise DSM with stereo pair images of PRISM. AVNIR-2 has four radiometric bands from blue to near infrared and uses for regional environment and disaster monitoring etc. The radiometric calibration and image quality evaluation are also important for AVNIR-2 as well as PRISM. This paper describes updated results of geometric calibration including geolocation determination accuracy evaluations of PRISM and AVNIR-2, image quality evaluation of PRISM, and validation of generated PRISM DSM. These works will be done during the ALOS mission life as an operational calibration to keep absolute accuracies of the standard products.
Influence of Visual Prism Adaptation on Auditory Space Representation.
Pochopien, Klaudia; Fahle, Manfred
2017-01-01
Prisms shifting the visual input sideways produce a mismatch between the visual versus felt position of one's hand. Prism adaptation eliminates this mismatch, realigning hand proprioception with visual input. Whether this realignment concerns exclusively the visuo-(hand)motor system or it generalizes to acoustic inputs is controversial. We here show that there is indeed a slight influence of visual adaptation on the perceived direction of acoustic sources. However, this shift in perceived auditory direction can be fully explained by a subconscious head rotation during prism exposure and by changes in arm proprioception. Hence, prism adaptation does only indirectly generalize to auditory space perception.
Prism Window for Optical Alignment
NASA Technical Reports Server (NTRS)
Tang, Hong
2008-01-01
A prism window has been devised for use, with an autocollimator, in aligning optical components that are (1) required to be oriented parallel to each other and/or at a specified angle of incidence with respect to a common optical path and (2) mounted at different positions along the common optical path. The prism window can also be used to align a single optical component at a specified angle of incidence. Prism windows could be generally useful for orienting optical components in manufacture of optical instruments. "Prism window" denotes an application-specific unit comprising two beam-splitter windows that are bonded together at an angle chosen to obtain the specified angle of incidence.
Feng, Yuncai; Liu, Youwen; Teng, Jinghua
2018-05-10
We propose, to the best of our knowledge, a new configuration of a biosensor based on the graphene-MoS 2 hybrid structure by adopting the lower refractive index MgF 2 prism in order to improve the sensitivity and the figure of merit (FOM). We can obtain an ultrasensitive sensor with values of sensitivity and FOM as high as 540.8°/RIU and 145/RIU, respectively, by modulating the parameters in the configuration and comparatively choosing a different absentee layer material. The proposed structure is applicable in the realization of an integrated device for the surface plasmon resonance biosensor.
Shih, Hsi-Fu; Chiu, Yi; Cheng, Stone; Lee, Yuan-Chin; Lu, Chun-Shin; Chen, Yung-Chih; Chiou, Jin-Chern
2012-08-20
This paper presents the prism-type holographic optical element (PT-HOE) design for a small-form-factor (SFF) optical pickup head (OPH). The surface of the PT-HOE was simulated by three steps of optimization and generated by binary optics. Its grating pattern was fabricated on the inclined plane of a microprism by using the standard photolithography and specific dicing procedures. The optical characteristics of the device were verified. Based on the virtual image method, the SFF-OPH with the device was assembled and realized.
Diffraction efficiency growth of nano-scale holographic recording produced in a corona discharge
NASA Astrophysics Data System (ADS)
Bodurov, I.; Yovcheva, T.; Vlaeva, I.; Viraneva, A.; Todorov, R.; Spassov, G.; Sainov, S.
2012-12-01
The nano-scale holographic gratings ware recorded in 29 nm and 56 nm thick As2S3 films. The chalcogenide layers were deposited on a transparent chromium electrode with thickness 10 nm, produced on a glass substrate. Both chromium and chalcogenide films were deposited in one vacuum cycle by e-beam and thermal evaporation, respectively. The diode 532 nm diode laser was used as a light source in the present holographic experiments. The total internal reflection arrangement (Stetson-Nassenstein) was used in holographic recordings. The reference beam was totally reflected from the air-As2S3 boundary surface by an input glass prism. The object beam was normally incident on the recording medium. The corona charging was performed by a needle fixed at the distance of 1 cm from the holographic recording medium by applying a - 5 kV voltage. The diffraction efficiency increased from 9 to 30 times when the corona discharge was applied during the holographic recording, in comparison to the uncharged recording. The possible reason of the observed effect is discussed on the basis of the Franz-Keldysh effect and Moss rule.
Teng, Tun-Chien; Lai, Wei-Che
2014-12-15
This study proposed a planar solar concentrator featuring alignment-free total-internal-reflection (TIR) collectors and an innovative compound tracker. The compound tracker, combining a mechanical single-axis tracker and scrollable prism sheets, can achieve a performance on a par with dual-axis tracking while reducing the cost of the tracking system and increasing its robustness. The alignment-free TIR collectors are assembled on the waveguide without requiring alignment, so the planar concentrator is relatively easily manufactured and markedly increases the feasibility for use in large concentrators. Further, the identical TIR collector is applicable to various-sized waveguide slab without requiring modification, which facilitates flexibility regarding the size of the waveguide slab. In the simulation model, the thickness of the slab was 2 mm, and its maximal length reached 6 m. With an average angular tolerance of ±0.6°, and after considering both the Fresnel loss and the angular spread of the sun, the simulation indicates that the waveguide concentrator of a 1000-mm length provides the optical efficiencies of 62-77% at the irradiance concentrations of 387-688, and the one of a 2000-mm length provides the optical efficiencies of 52-64.5% at the irradiance concentrations of 645-1148. Alternatively, if a 100-mm horizontally staggered waveguide slab is collocated with the alignment-free TIR collectors, the optical efficiency would be greatly improved up to 91.5% at an irradiance concentration of 1098 (C(geo) = 1200X).
Some Experiments with Thin Prisms.
ERIC Educational Resources Information Center
Fernando, P. C. B.
1980-01-01
Described are several experiments, for a course in geometrical optics or for a college physics laboratory, which have a bearing on ophthalmic optics. Experiments include the single thin prism, crossed prisms, and the prismatic power of a lens. (Author/DS)
Limited Plasticity of Prismatic Visuomotor Adaptation
Wischhusen, Sven; Fahle, Manfred
2017-01-01
Movements toward an object displaced optically through prisms adapt quickly, a striking example for the plasticity of neuronal visuomotor programs. We investigated the degree and time course of this system’s plasticity. Participants performed goal-directed throwing or pointing movements with terminal feedback before, during, and after wearing prism goggles shifting the visual world laterally either to the right or to the left. Prism adaptation was incomplete even after 240 throwing movements, still deviating significantly laterally by on average of 0.8° (CI = 0.20°) at the end of the adaptation period. The remaining lateral deviation was significant for pointing movements only with left shifting prisms. In both tasks, removal of the prisms led to an aftereffect which disappeared in the course of further training. This incomplete prism adaptation may be caused by movement variability combined with an adaptive neuronal control system exhibiting a finite capacity for evaluating movement errors. PMID:28473909
Inclusive Security and Peaceful Societies: Exploring the Evidence
2016-03-01
655 mothers to deradicalize 1,024 young men and boys , rehabilitating INCLUSIVE SECURITY AND PEACEFUL SOCIETIES PRISM 6, no. 1 FEATURES | 23 The...approaches to breaking impasses dur- ing a stalled peace process, from nonviolent sit-ins to unorthodox tactics like blocking doors or even withholding sex ...Processes,” (New York: International Peace Institute, 2015). 9 Valerie Hudson, Bonnie Ballif-Spanvill, Mary Caprioli, and Chad F. Emmett, Sex and
Optofluidic solar concentrators using electrowetting tracking: Concept, design, and characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, JT; Park, S; Chen, CL
2013-03-01
We introduce a novel optofluidic solar concentration system based on electrowetting tracking. With two immiscible fluids in a transparent cell, we can actively control the orientation of fluid fluid interface via electrowetting. The naturally-formed meniscus between the two liquids can function as a dynamic optical prism for solar tracking and sunlight steering. An integrated optofluidic solar concentrator can be constructed from the liquid prism tracker in combination with a fixed and static optical condenser (Fresnel lens). Therefore, the liquid prisms can adaptively focus sunlight on a concentrating photovoltaic (CPV) cell sitting on the focus of the Fresnel lens as themore » sun moves. Because of the unique design, electrowetting tracking allows the concentrator to adaptively track both the daily and seasonal changes of the sun's orbit (dual-axis tracking) without bulky, expensive and inefficient mechanical moving parts. This approach can potentially reduce capital costs for CPV and increases operational efficiency by eliminating the power consumption of mechanical tracking. Importantly, the elimination of bulky tracking hardware and quiet operation will allow extensive residential deployment of concentrated solar power. In comparison with traditional silicon-based photovoltaic (PV) solar cells, the electrowetting-based self-tracking technology will generate,similar to 70% more green energy with a 50% cost reduction. (C) 2013 Elsevier Ltd. All rights reserved.« less
Massaroni, Carlo; Cassetta, Eugenio; Silvestri, Sergio
2017-10-01
Respiratory assessment can be carried out by using motion capture systems. A geometrical model is mandatory in order to compute the breathing volume as a function of time from the markers' trajectories. This study describes a novel model to compute volume changes and calculate respiratory parameters by using a motion capture system. The novel method, ie, prism-based method, computes the volume enclosed within the chest by defining 82 prisms from the 89 markers attached to the subject chest. Volumes computed with this method are compared to spirometry volumes and to volumes computed by a conventional method based on the tetrahedron's decomposition of the chest wall and integrated in a commercial motion capture system. Eight healthy volunteers were enrolled and 30 seconds of quiet breathing data collected from each of them. Results show a better agreement between volumes computed by the prism-based method and the spirometry (discrepancy of 2.23%, R 2 = .94) compared to the agreement between volumes computed by the conventional method and the spirometry (discrepancy of 3.56%, R 2 = .92). The proposed method also showed better performances in the calculation of respiratory parameters. Our findings open up prospects for the further use of the new method in the breathing assessment via motion capture systems.
A comparison of four different lens mappers.
Larrue, Denis; Legeard, Morgane
2014-11-01
Recently, a number of lens mappers have become available for measuring the detailed optical properties of progressive addition lenses (PALs). The goal of this study was to compare the results obtained from several different lens mappers for a range of different lenses. The optical power maps of six lenses-two single-vision lenses, a parallel-sided slide, a flat prism, and two progressive lenses-were measured using four different lens mappers: the Dual Lens Mapper, the Nimo TR4005, the Rotlex Class Plus, and the Visionix VM2500. The repeatability of the instruments was also evaluated. All lens mappers gave very repeatable measurements; however, measurements among the lens mappers varied considerably. Differences appeared to be above the tolerance at the optical center for measurements of single-vision lenses, and these differences increase in the periphery up to 1.00 diopter. Similar differences were observed for the PALs, even increased by prism and base curve effect, with figures greater than 1 diopter in the periphery. The measurements made on the prism and lenses with different base curves suggest that base curve, thickness, and prismatic effect can all contribute to the differences among instruments. Measurements of a given lens taken with different lens mappers can vary substantially. Particular caution should be exercised when interpreting power maps for PALs taken with different instruments.
Accuracy improvement of the ice flow rate measurements on Antarctic ice sheet by DInSAR method
NASA Astrophysics Data System (ADS)
Shiramizu, Kaoru; Doi, Koichiro; Aoyama, Yuichi
2015-04-01
DInSAR (Differential Interferometric Synthetic Aperture Radar) is an effective tool to measure the flow rate of slow flowing ice streams on Antarctic ice sheet with high resolution. In the flow rate measurement by DInSAR method, we use Digital Elevation Model (DEM) at two times in the estimating process. At first, we use it to remove topographic fringes from InSAR images. And then, it is used to project obtained displacements along Line-Of-Sight (LOS) direction to the actual flow direction. ASTER-GDEM widely-used for InSAR prosessing of the data of polar region has a lot of errors especially in the inland ice sheet area. Thus the errors yield irregular flow rates and directions. Therefore, quality of DEM has a substantial influence on the ice flow rate measurement. In this study, we created a new DEM (resolution 10m; hereinafter referred to as PRISM-DEM) based on ALOS/PRISM images, and compared PRISM-DEM and ASTER-GDEM. The study area is around Skallen, 90km south from Syowa Station, in the southern part of Sôya Coast, East Antarctica. For making DInSAR images, we used ALOS/PALSAR data of 13 pairs (Path633, Row 571-572), observed during the period from November 23, 2007 through January 16, 2011. PRISM-DEM covering the PALSAR scene was created from nadir and backward view images of ALOS/PRISM (Observation date: 2009/1/18) by applying stereo processing with a digital mapping equipment, and then the automatically created a primary DEM was corrected manually to make a final DEM. The number of irregular values of actual ice flow rate was reduced by applying PRISM-DEM compared with that by applying ASTER-GDEM. Additionally, an averaged displacement of approximately 0.5cm was obtained by applying PRISM-DEM over outcrop area, where no crustal displacement considered to occur during the recurrence period of ALOS/PALSAR (46days), while an averaged displacement of approximately 1.65 cm was observed by applying ASTER-GDEM. Since displacements over outcrop area are considered to be apparent ones, the average could be a measure of flow rate estimation accuracy by DInSAR. Therefore, it is concluded that the accuracy of the ice flow rate measurement can be improved by using PRISM-DEM. In this presentation, we will show the results of the estimated flow rate of ice streams in the region of interest, and discuss the additional accuracy improvement of this method.
Salt-induced square prism Pd microtubes and their ethanol electrocatalysis properties
NASA Astrophysics Data System (ADS)
Jiang, Kunpeng; Ma, Shenghua; Wang, Yinan; Zhang, Ying; Han, Xiaojun
2017-05-01
The synthesis of square prism tubes are always challenging due to their thermo and dynamical instability. We demonstrated a simple method using Pd2+ doped PoPD oligomers as building blocks to assemble into 1D square prism metal-organic microtubes, which consists of cataphracted nanosheets on the surfaces. After high temperature treatment, the microtubes became square prism Pd tubes with a cross section size of 3 μm. The pure Pd microtubes showed excellent catalyzing activity towards the electro oxidation of ethanol. Their electrochemically active surface area is 48.2 m2 g-1, which indicates the square prism Pd tubes have great potential in the field of fuel cell.
Tandem internal models execute motor learning in the cerebellum.
Honda, Takeru; Nagao, Soichi; Hashimoto, Yuji; Ishikawa, Kinya; Yokota, Takanori; Mizusawa, Hidehiro; Ito, Masao
2018-06-25
In performing skillful movement, humans use predictions from internal models formed by repetition learning. However, the computational organization of internal models in the brain remains unknown. Here, we demonstrate that a computational architecture employing a tandem configuration of forward and inverse internal models enables efficient motor learning in the cerebellum. The model predicted learning adaptations observed in hand-reaching experiments in humans wearing a prism lens and explained the kinetic components of these behavioral adaptations. The tandem system also predicted a form of subliminal motor learning that was experimentally validated after training intentional misses of hand targets. Patients with cerebellar degeneration disease showed behavioral impairments consistent with tandemly arranged internal models. These findings validate computational tandemization of internal models in motor control and its potential uses in more complex forms of learning and cognition. Copyright © 2018 the Author(s). Published by PNAS.
Laboratory Experiments for Exploring the Surface Plasmon Resonance
ERIC Educational Resources Information Center
Pluchery, Olivier; Vayron, Romain; Van, Kha-Man
2011-01-01
The surface plasmon wave is a surface wave confined at the interface between a dielectric and a metal. The excitation of the surface plasmon resonance (SPR) on a gold thin film is discussed within the Kretschmann configuration, where the coupling with the excitation light is achieved by means of a prism in total reflection. The electromagnetic…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weirs, V. Gregory
2012-03-01
Prism is a ParaView plugin that simultaneously displays simulation data and material model data. This document describes its capabilities and how to use them. A demonstration of Prism is given in the first section. The second section contains more detailed notes on less obvious behavior. The third and fourth sections are specifically for Alegra and CTH users. They tell how to generate the simulation data and SESAME files and how to handle aspects of Prism use particular to each of these codes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Fei, E-mail: long.drf@gmail.com; Chi, Shangsen; Institute of Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083
Wurtzite Cu{sub 2}ZnSnS{sub 4} (CZTS) hexagonal prisms were synthesized by a simple ultrasound-microwave solvothermal method. The product was characterized by XRD, FESEM, EDS, TEM, Raman and UV–vis spectrometer. The hexagonal prisms were 0.5–2 μm wide and 5–12 μm long. The PVP played an important role in the formation of the CZTS hexagonal prisms. In addition, the ultrasound-assisted microwave process was helpful for synthesis of wurtzite rather than kesterite phase CZTS. A nucleation–dissolution–recrystallization mechanism was also proposed to explain the growth of the CZTS hexagonal prisms. - Graphical abstract: Wurtzite Cu{sub 2}ZnSnS{sub 4} hexagonal prisms were synthesized by ultrasound-microwave solvothermal method.more » The ultrasound-assisted microwave process and PVP were useful to the growth of CZTS. A nucleation–dissolution–recrystallization growth mechanism was also proposed. - Highlights: • Wurtzite Cu{sub 2}ZnSnS{sub 4} was prepared by ultrasound-assisted microwave solvothermal method. • The wurtzite CZTS hexagonal prisms are demonstrated a band gap of 1.49 eV. • Synergistic effect of ultrasound and microwave is helpful to prepare Wurtzite CZTS. • PVP plays an important role in the formation of the CZTS hexagonal prisms. • Nucleation–dissolution–recrystallization growth mechanism of the CZTS was proposed.« less
Eppinger, Robert G.; Giles, Stuart A.; Lee, Gregory K.; Smith, Steven M.
2015-01-01
The geochemical sample media collected by the BGS and BRGM under the PRISM-I contract included rock, sediment, regolith, and soil samples. Details on sample collection procedures are in unpublished reports available from PRISM. These samples were analyzed under PRISM-I contract by ALS Chemex Laboratories using various combinations of modern methods including fire-assay inductively coupled plasma-atomic emission spectrometry (ICPAES) and ICP-mass spectrometry (ICP-MS) for Au; multi-acid digestion, atomic absorption spectroscopy (AAS) for Ag and As; 47-element, four-acid digestion, ICP-MS; 27-element, fouracid digestion, ICP-AES; special four-acid ICP-MS techniques for Pt and B; fire assay followed by ICP-AES for platinum-group elements; whole-rock analyses by wavelength dispersive X-ray fluorescence (XRF); special techniques for loss-on-ignition, inorganic C, and total S; and special ore-grade AAS techniques for Ag, Au, Cu, Ni, Pb, and Zn. Around 30,000 samples were analyzed by at least one technique. However, it is stressed here that: (1) there was no common sample medium collected at all sites, likely due to the vast geological and geomorphologic differences across the country, (2) the sample site distribution is very irregular, likely due in part to access constraints and sand dune cover, and (3) there was no common across-the-board trace element analytical package used for all samples. These three aspects fundamentally affect the ability to produce country-wide geochemical maps of Mauritania. Gold (Au), silver (Ag), and arsenic (As) were the three elements that were most commonly analyzed.
Coskun, Ahmet F; Sencan, Ikbal; Su, Ting-Wei; Ozcan, Aydogan
2011-01-06
We demonstrate lensfree on-chip fluorescent imaging of transgenic Caenorhabditis elegans (C. elegans) over an ultra-wide field-of-view (FOV) of e.g., >2-8 cm(2) with a spatial resolution of ∼10 µm. This is the first time that a lensfree on-chip platform has successfully imaged fluorescent C. elegans samples. In our wide-field lensfree imaging platform, the transgenic samples are excited using a prism interface from the side, where the pump light is rejected through total internal reflection occurring at the bottom facet of the substrate. The emitted fluorescent signal from C. elegans samples is then recorded on a large area opto-electronic sensor-array over an FOV of e.g., >2-8 cm(2), without the use of any lenses, thin-film interference filters or mechanical scanners. Because fluorescent emission rapidly diverges, such lensfree fluorescent images recorded on a chip look blurred due to broad point-spread-function of our platform. To combat this resolution challenge, we use a compressive sampling algorithm to uniquely decode the recorded lensfree fluorescent patterns into higher resolution images, demonstrating ∼10 µm resolution. We tested the efficacy of this compressive decoding approach with different types of opto-electronic sensors to achieve a similar resolution level, independent of the imaging chip. We further demonstrate that this wide FOV lensfree fluorescent imaging platform can also perform sequential bright-field imaging of the same samples using partially-coherent lensfree digital in-line holography that is coupled from the top facet of the same prism used in fluorescent excitation. This unique combination permits ultra-wide field dual-mode imaging of C. elegans on a chip which could especially provide a useful tool for high-throughput screening applications in biomedical research.
Ozcan, Aydogan
2011-01-01
We demonstrate lensfree on-chip fluorescent imaging of transgenic Caenorhabditis elegans (C. elegans) over an ultra-wide field-of-view (FOV) of e.g., >2–8 cm2 with a spatial resolution of ∼10µm. This is the first time that a lensfree on-chip platform has successfully imaged fluorescent C. elegans samples. In our wide-field lensfree imaging platform, the transgenic samples are excited using a prism interface from the side, where the pump light is rejected through total internal reflection occurring at the bottom facet of the substrate. The emitted fluorescent signal from C. elegans samples is then recorded on a large area opto-electronic sensor-array over an FOV of e.g., >2–8 cm2, without the use of any lenses, thin-film interference filters or mechanical scanners. Because fluorescent emission rapidly diverges, such lensfree fluorescent images recorded on a chip look blurred due to broad point-spread-function of our platform. To combat this resolution challenge, we use a compressive sampling algorithm to uniquely decode the recorded lensfree fluorescent patterns into higher resolution images, demonstrating ∼10 µm resolution. We tested the efficacy of this compressive decoding approach with different types of opto-electronic sensors to achieve a similar resolution level, independent of the imaging chip. We further demonstrate that this wide FOV lensfree fluorescent imaging platform can also perform sequential bright-field imaging of the same samples using partially-coherent lensfree digital in-line holography that is coupled from the top facet of the same prism used in fluorescent excitation. This unique combination permits ultra-wide field dual-mode imaging of C. elegans on a chip which could especially provide a useful tool for high-throughput screening applications in biomedical research. PMID:21253611
A 1-Diopter Vertical Prism Induces a Decrease of Head Rotation: A Pilot Investigation.
Matheron, Eric; Zandi, Ava; Wang, Danping; Kapoula, Zoï
2016-01-01
Clinical studies in non-specific chronic arthralgia and back pain seem to indicate an association between vertical heterophoria (VH - latent vertical retinal misalignment) and asymmetrical head rotation. Such clinical observations suggest a link between VH and head rotation, but this was never tested. The purpose of this study was to simulate a VH in healthy subjects and examine its influence on the amplitude of active head rotation during 3D motion capture in upright stance. Subjects were asked to rotate their head three times from the straight ahead position and then to the right, back to straight ahead, to the left, and back to the straight ahead again. Three randomized conditions were run: normal viewing, with a 1-diopter prism base down on the dominant eye, or the non-dominant eye. The most important finding is that the experimental VH whichever the eye with the prism induces a significant decrease in the mean angle of head rotation compared to the normal viewing condition. This decrease was significant for rotation to the left. We suggest that the prism-induced VH modifies the reference posture and thereby affects head rotation; further studies are needed to confirm this effect and to extend to other types of dynamic activities.
The impact of prism adaptation test on surgical outcomes in patients with primary exotropia.
Kiyak Yilmaz, Ayse; Kose, Suheyla; Guven Yilmaz, Suzan; Uretmen, Onder
2015-05-01
We aimed to determine the impact of the preoperative prism adaptation test (PAT) on surgical outcomes in patients with primary exotropia. Thirty-eight consecutive patients with primary exotropia were enrolled. Pre-operative PAT was performed in 18 randomly selected patients (Group 1). Surgery was based on the angle of deviation at distance measured after PAT. The remaining 20 patients in whom PAT was not performed comprised Group 2. Surgery was based on the angle of deviation at distance in these patients. Surgical success was defined as ocular alignment within eight prism dioptres (PD) of orthophoria. Satisfactory motor alignment (± 8 PD) was achieved in 16 Group 1 patients (88.9 per cent) and 16 Group 2 patients (80 per cent) one year after surgery (p = 0.6; chi-square test). There were no statistically significant differences in demographic parameters, pre-operative and post-operative angle of deviation between the two groups (p > 0.05; Mann-Whitney U and chi-square tests). Nine patients in Group 1 (50 per cent) and two patients in Group 2 (10 per cent) had increased binocular vision one year post-operatively. A statistically significant difference was determined in terms of change in binocular single vision between the two groups (p = 0.01; chi-square test). Although the prism adaptation test did not lead to a significant increment in motor success, it may be helpful in achieving a more favourable functional surgical outcome in patients with primary exotropia. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.
Carson, Bobb; Seke, Erol; Paskevich, Valerie F.; Holmes, Mark L.
1994-01-01
Point-discharge fluid expulsion on accretionary prisms is commonly indicated by diagenetic deposition of calcium carbonate cements and gas hydrates in near-surface (<10 m below seafloor; mbsf) hemipelagic sediment. The contrasting clastic and diagenetic lithologies should be apparent in side scan images. However, sonar also responds to variations in bottom slope, so unprocessed images mix topographic and lithologic information. We have processed GLORIA imagery from the Oregon continental margin to remove topographic effects. A synthetic side scan image was created initially from Sea Beam bathymetric data and then was subtracted iteratively from the original GLORIA data until topographic features disappeared. The residual image contains high-amplitude backscattering that we attribute to diagenetic deposits associated with fluid discharge, based on submersible mapping, Ocean Drilling Program drilling, and collected samples. Diagenetic deposits are concentrated (1) near an out-of-sequence thrust fault on the second ridge landward of the base of the continental slope, (2) along zones characterized by deep-seated strikeslip faults that cut transversely across the margin, and (3) in undeformed Cascadia Basin deposits which overlie incipient thrust faults seaward of the toe of the prism. There is no evidence of diagenetic deposition associated with the frontal thrust that rises from the dècollement. If the dècollement is an important aquifer, apparently the fluids are passed either to the strike-slip faults which intersect the dècollement or to the incipient faults in Cascadia Basin for expulsion. Diagenetic deposits seaward of the prism toe probably consist dominantly of gas hydrates.
49 CFR 390.203 - PRISM State registration/biennial updates.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the Performance and Registration Information Systems Management (PRISM) program (authorized under... FEDERAL MOTOR CARRIER SAFETY REGULATIONS; GENERAL Unified Registration System § 390.203 PRISM State... procedures, provided the State has integrated the USDOT registration/update capability into its vehicle...
49 CFR 390.203 - PRISM State registration/biennial updates.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the Performance and Registration Information Systems Management (PRISM) program (authorized under... FEDERAL MOTOR CARRIER SAFETY REGULATIONS; GENERAL Unified Registration System § 390.203 PRISM State... procedures, provided the State has integrated the USDOT registration/update capability into its vehicle...
Sarri, Margarita; Greenwood, Richard; Kalra, Lalit; Driver, Jon
2011-01-01
Previous research has shown that prism adaptation (prism adaptation) can ameliorate several symptoms of spatial neglect after right-hemisphere damage. But the mechanisms behind this remain unclear. Recently we reported that prisms may increase leftward awareness for neglect in a task using chimeric visual objects, despite apparently not affecting awareness in a task using chimeric emotional faces (Sarri et al., 2006). Here we explored potential reasons for this apparent discrepancy in outcome, by testing further whether the lack of a prism effect on the chimeric face task task could be explained by: i) the specific category of stimuli used (faces as opposed to objects); ii) the affective nature of the stimuli; and/or iii) the particular task implemented, with the chimeric face task requiring forced-choice judgements of lateral ‘preference’ between pairs of identical, but left/right mirror-reversed chimeric face tasks (as opposed to identification for the chimeric object task). We replicated our previous pattern of no impact of prisms on the emotional chimeric face task here in a new series of patients, while also similarly finding no beneficial impact on another lateral ‘preference’ measure that used non-face non-emotional stimuli, namely greyscale gradients. By contrast, we found the usual beneficial impact of prism adaptation (prism adaptation) on some conventional measures of neglect, and improvements for at least some patients in a different face task, requiring explicit discrimination of the chimeric or non-chimeric nature of face stimuli. The new findings indicate that prism therapy does not alter spatial biases in neglect as revealed by ‘lateral preference tasks’ that have no right or wrong answer (requiring forced-choice judgements on left/right mirror-reversed stimuli), regardless of whether these employ face or non-face stimuli. But our data also show that prism therapy can beneficially modulate some aspects of visual awareness in spatial neglect not only for objects, but also for face stimuli, in some cases. PMID:20171612
Christophe, Laure; Chabanat, Eric; Delporte, Ludovic; Revol, Patrice; Volckmann, Pierre; Jacquin-Courtois, Sophie; Rossetti, Yves
Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations.
3D Printed Prisms with Tunable Dispersion for the THz Frequency Range
NASA Astrophysics Data System (ADS)
Busch, Stefan F.; Castro-Camus, Enrique; Beltran-Mejia, Felipe; Balzer, Jan C.; Koch, Martin
2018-04-01
Here, we present a 3D printed prism for THz waves made out of an artificial dielectric material in which the dispersion can be tuned by external compression. The artificial material consists of thin dielectric layers with variable air spacings which has been produced using a fused deposition molding process. The material properties are carefully characterized and the functionality of the prisms is in a good agreement with the underlying theory. These prisms are durable, lightweight, inexpensive, and easy to produce.
3D Printed Prisms with Tunable Dispersion for the THz Frequency Range
NASA Astrophysics Data System (ADS)
Busch, Stefan F.; Castro-Camus, Enrique; Beltran-Mejia, Felipe; Balzer, Jan C.; Koch, Martin
2018-06-01
Here, we present a 3D printed prism for THz waves made out of an artificial dielectric material in which the dispersion can be tuned by external compression. The artificial material consists of thin dielectric layers with variable air spacings which has been produced using a fused deposition molding process. The material properties are carefully characterized and the functionality of the prisms is in a good agreement with the underlying theory. These prisms are durable, lightweight, inexpensive, and easy to produce.
Optical power splitter for splitting high power light
English, Jr., Ronald E.; Christensen, John J.
1995-01-01
An optical power splitter for the distribution of high-power light energy has a plurality of prisms arranged about a central axis to form a central channel. The input faces of the prisms are in a common plane which is substantially perpendicular to the central axis. A beam of light which is substantially coaxial to the central axis is incident on the prisms and at least partially strikes a surface area of each prism input face. The incident beam also partially passes through the central channel.
Retroreflective Phase Retardation Prisms.
1981-06-01
resonant cavity of a 1.064 Mm laser. This report shows that it is possible to coat the reflecting surfaces of a porro prism so that incident plane...with controlled phase retardation can be made by coating each reflecting surface of a porro prism with a single dielectric film. The amount of phase...of angle of incidence (n, < n2) S. Phase change on reflection as a function of angle of incidence (n" n ) [RL-0202-’R 6. Porro prism 7. Phase change
[Integration design and diffraction characteristics analysis of prism-grating-prism].
He, Tian-Bo; Bayanheshig; Li, Wen-Hao; Kong, Peng; Tang, Yu-Guo
2014-01-01
Prism-grating-prism (PGP) module is the important dispersing component in the hyper spectral imager. In order to effectively predict the distribution of diffraction efficiency of the whole PGP component and its diffraction characteristics before fabrication, a method of the PGP integration design is proposed. From the point of view of the volume phase holographic grating (VPHG) design, combined with the restrictive correlation between the various parameters of prisms and grating, we compiled the analysis software for calculating the whole PGP's diffraction efficiency. Furthermore, the effects of the structure parameters of prisms and grating on the PGP's diffraction characteristics were researched in detail. In particular we discussed the Bragg wavelength shift behaviour of the grating and a broadband PGP spectral component with high diffraction efficiency was designed for the imaging spectrometers. The result of simulation indicated that the spectral bandwidth of the PGP becomes narrower with the dispersion coefficient of prism 1 material decreasing; Bragg wavelength shift characteristics broaden the bandwidth of VPHG both spectrally and angularly, higher angular selectivity is desirable for selection requirements of the prism 1 material, and it can be easily tuned to achieve spectral bandwidth suitable for imaging PGP spectrograph; the vertex angle of prism 1, the film thickness and relative permittivity modulation of the grating have a significant impact on the distribution of PGP's diffraction efficiency, so precision control is necessary when fabrication. The diffraction efficiency of the whole PGP component designed by this method is no less than 50% in the wavelength range from 400 to 1000 nm, the specific design parameters have been given in this paper that have a certain reference value for PGP fabrication.
Does prism width from the shell prismatic layer have a random distribution?
NASA Astrophysics Data System (ADS)
Vancolen, Séverine; Verrecchia, Eric
2008-10-01
A study of the distribution of the prism width inside the prismatic layer of Unio tumidus (Philipsson 1788, Diss Hist-Nat, Berling, Lundæ) from Lake Neuchâtel, Switzerland, has been conducted in order to determine whether or not this distribution is random. Measurements of 954 to 1,343 prism widths (depending on shell sample) have been made using a scanning electron microscope in backscattered electron mode. A white noise test has been applied to the distribution of prism sizes (i.e. width). It shows that there is no temporal cycle that could potentially influence their formation and growth. These results suggest that prism widths are randomly distributed, and related neither to external rings nor to environmental constraints.
Negative index effects from a homogeneous positive index prism
NASA Astrophysics Data System (ADS)
Marcus, Sherman W.; Epstein, Ariel
2017-12-01
Cellular structured negative index metamaterials in the form of a right triangular prism have often been tested by observing the refraction of a beam across the prism hypotenuse which is serrated in order to conform to the cell walls. We show that not only can this negative index effect be obtained from a homogeneous dielectric prism having a positive index of refraction, but in addition, for sampling at the walls of the cellular structure, the phase in the material has the illusory appearance of moving in a negative direction. Although many previous reports relied on refraction direction and phase velocity of prism structures to verify negative index design, our investigation indicates that to unambiguously demonstrate material negativity additional empirical evidence is required.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Junjie; Jia, Hongzhi, E-mail: hzjia@usst.edu.cn
2015-11-15
We propose error analysis using a rotating coordinate system with three parameters of linearly polarized light—incidence angle, azimuth angle on the front surface, and angle between the incidence and vibration planes—and demonstrate the method on a rotating birefringent prism system. The transmittance and angles are calculated plane-by-plane using a birefringence ellipsoid model and the final transmitted intensity equation is deduced. The effects of oblique incidence, light interference, beam convergence, and misalignment of the rotation and prism axes are discussed. We simulate the entire error model using MATLAB and conduct experiments based on a built polarimeter. The simulation and experimental resultsmore » are consistent and demonstrate the rationality and validity of this method.« less
Standardization of Questions in Rare Disease Registries: The PRISM Library Project.
Richesson, Rachel Lynn; Shereff, Denise; Andrews, James Everett
2012-10-10
Patient registries are often a helpful first step in estimating the impact and understanding the etiology of rare diseases - both requisites for the development of new diagnostics and therapeutics. The value and utility of patient registries rely on the use of both well-constructed structured research questions and relevant answer sets accompanying them. There are currently no clear standards or specifications for developing registry questions, and there are no banks of existing questions to support registry developers. This paper introduces the [Rare Disease] PRISM (Patient Registry Item Specifications and Metadata for Rare Disease) project, a library of standardized questions covering a broad spectrum of rare diseases that can be used to support the development of new registries, including Internet-based registries. A convenience sample of questions was identified from well-established (>5 years) natural history studies in various diseases and from several existing registries. Face validity of the questions was determined by review by many experts (both terminology experts at the College of American Pathologists (CAP) and research and informatics experts at the University of South Florida (USF)) for commonality, clarity, and organization. Questions were re-worded slightly, as needed, to make the full semantics of the question clear and to make the questions generalizable to multiple diseases where possible. Questions were indexed with metadata (structured and descriptive information) using a standard metadata framework to record such information as context, format, question asker and responder, and data standards information. At present, PRISM contains over 2,200 questions, with content of PRISM relevant to virtually all rare diseases. While the inclusion of disease-specific questions for thousands of rare disease organizations seeking to develop registries would present a challenge for traditional standards development organizations, the PRISM library could serve as a platform to liaison between rare disease communities and existing standardized controlled terminologies, item banks, and coding systems. If widely used, PRISM will enable the re-use of questions across registries, reduce variation in registry data collection, and facilitate a bottom-up standardization of patient registries. Although it was initially developed to fulfill an urgent need in the rare disease community for shared resources, the PRISM library of patient-directed registry questions can be a valuable resource for registries in any disease - whether common or rare. N/A.
Standardization of Questions in Rare Disease Registries: The PRISM Library Project
Shereff, Denise; Andrews, James Everett
2012-01-01
Background Patient registries are often a helpful first step in estimating the impact and understanding the etiology of rare diseases - both requisites for the development of new diagnostics and therapeutics. The value and utility of patient registries rely on the use of both well-constructed structured research questions and relevant answer sets accompanying them. There are currently no clear standards or specifications for developing registry questions, and there are no banks of existing questions to support registry developers. Objective This paper introduces the [Rare Disease] PRISM (Patient Registry Item Specifications and Metadata for Rare Disease) project, a library of standardized questions covering a broad spectrum of rare diseases that can be used to support the development of new registries, including Internet-based registries. Methods A convenience sample of questions was identified from well-established (>5 years) natural history studies in various diseases and from several existing registries. Face validity of the questions was determined by review by many experts (both terminology experts at the College of American Pathologists (CAP) and research and informatics experts at the University of South Florida (USF)) for commonality, clarity, and organization. Questions were re-worded slightly, as needed, to make the full semantics of the question clear and to make the questions generalizable to multiple diseases where possible. Questions were indexed with metadata (structured and descriptive information) using a standard metadata framework to record such information as context, format, question asker and responder, and data standards information. Results At present, PRISM contains over 2,200 questions, with content of PRISM relevant to virtually all rare diseases. While the inclusion of disease-specific questions for thousands of rare disease organizations seeking to develop registries would present a challenge for traditional standards development organizations, the PRISM library could serve as a platform to liaison between rare disease communities and existing standardized controlled terminologies, item banks, and coding systems. Conclusions If widely used, PRISM will enable the re-use of questions across registries, reduce variation in registry data collection, and facilitate a bottom-up standardization of patient registries. Although it was initially developed to fulfill an urgent need in the rare disease community for shared resources, the PRISM library of patient-directed registry questions can be a valuable resource for registries in any disease – whether common or rare. Trial Registration N/A PMID:23611924
Phase-Scrambler Plate Spreads Point Image
NASA Technical Reports Server (NTRS)
Edwards, Oliver J.; Arild, Tor
1992-01-01
Array of small prisms retrofit to imaging lens. Phase-scrambler plate essentially planar array of small prisms partitioning aperture of lens into many subapertures, and prism at each subaperture designed to divert relatively large diffraction spot formed by that subaperture to different, specific point on focal plane.
Finite element analysis and experiment on high pressure apparatus with split cylinder
NASA Astrophysics Data System (ADS)
Zhao, Liang; Li, Mingzhe; Yang, Yunfei; Wang, Bolong; Li, Yi
2017-07-01
Ultra-high pressure belt-type die was designed with a large sample volume prism cavity and a split cylinder which was divided into eight segments to eliminate circumferential stress. The cylinder of this type die has no cambered surface on inner wall, and the inner hole is a hexagonal prism-type cavity. The divided bodies squeeze with each other, providing the massive support and lateral support effect of the cylinder. Simulation results indicate that the split cylinder with the prism cavity possesses much smaller stress and more uniform stress distribution. The split cylinder with the prism cavity has been shown to bear larger compressive stresses in radial, circumferential and axial directions due to its structure, and tungsten carbide is most effective in pure compression so this type cylinder could bear higher pressure. Experimental results prove that the high pressure apparatus with a prism-type cavity could bear higher pressure. The apparatus with a prism cavity could bear 52.2% more pressure than the belt-type die.
DSM Generation from ALSO/PRISM Images Using SAT-PP
NASA Astrophysics Data System (ADS)
Wolff, Kirsten; Gruen, Armin
2008-11-01
One of the most important products of ALOS/PRISM image data are accurate DSMs. To exploit the full potential of the full resolution of PRISM for DSM generation, a highly developed image matcher is needed. As a member of the validation and calibration team for PRISM we published earlier results of DSM generation using PRISM image triplets in combination with our software package SAT-PP. The overall accuracy across all object and image features for all tests lies between 1-5 pixels in matching, depending primarily on surface roughness, vegetation, image texture and image quality. Here we will discuss some new results. We focus on four different topics: the use of two different evaluation methods, the difference between a 5m and a 10m GSD for the final PRISM DSM, the influence of the level of initial information and the comparison of the quality of different combinations of the three different views forward, nadir and backward. All tests have been conducted with our testfield Bern/Thun, Switzerland.
Marinello, Elena; Linder, Dennis; Spoto, Andrea; Palmer, Katie; Rohrer, Peter Michael; Büchi, Stefan; Trapp, Michael; Trapp, Eva-Maria; Hoerlesberger, Nina; Piaserico, Stefano; Peserico, Andrea; Gatta, Michela; Belloni Fortina, Anna
2016-01-01
There is a need to improve the quality of communication between clinicians and parents of young patients with atopic eczema (AE). To create a tool to measure the suffering that caregivers experience in association with their child's AE (Caregiver Pictorial Representation of Illness and Self-Measure, Caregiver-PRISM), assess the validity and reliability, and identify factors associated with caregiver suffering. Caregiver-PRISM was administered to 45 parents of patients from an AE outpatient service (Padua, Italy). Caregiver-PRISM had a good test-retest reliability (r = 0.85; t7 = 4.13; p < 0.05), content validity and construct validity when used in parents of AE children. Parents with a less positive family affective climate, higher education, or with children following a diet experienced higher suffering associated with their child's AE, demonstrated by lower Caregiver-PRISM scores (p < 0.05). Our results support the use of Caregiver-PRISM in parents of AE patients to assess suffering associated with patients' illness. © 2016 S. Karger AG, Basel.
Porro prism lasers: a new perspective
NASA Astrophysics Data System (ADS)
Burger, Liesl; Forbes, Andrew
2008-08-01
Porro prism lasers are insensitive to misalignment caused by, for example, shock and temperature variation, making them useful in field applications, for example in target designation and range-finding systems. This property is a result of the property of Porro prisms that they return a reflected beam parallel to the incident beam, regardless of any tilt on the prism. These lasers are generally used in a marginally stable or unstable configuration for low divergence, but in the stable configuration some interesting kaleidoscope modes can be modelled. In previous work on Porro prism resonators we formulated an analytical method of determining which Porro angles resonate and result in petal output modes, as well as the corresponding number of petals. This work has been verified using a numerical model as well as experimentally. We have developed this work further and have investigated the losses associated with a range of Porro angles as well as the effects of these losses on the resulting modes. We conclude by summarizing the design considerations for Porro prism lasers.
ePRISM: A case study in multiple proxy and mixed temporal resolution integration
Robinson, Marci M.; Dowsett, Harry J.
2010-01-01
As part of the Pliocene Research, Interpretation and Synoptic Mapping (PRISM) Project, we present the ePRISM experiment designed I) to provide climate modelers with a reconstruction of an early Pliocene warm period that was warmer than the PRISM interval (similar to 3.3 to 3.0 Ma), yet still similar in many ways to modern conditions and 2) to provide an example of how best to integrate multiple-proxy sea surface temperature (SST) data from time series with varying degrees of temporal resolution and age control as we begin to build the next generation of PRISM, the PRISM4 reconstruction, spanning a constricted time interval. While it is possible to tie individual SST estimates to a single light (warm) oxygen isotope event, we find that the warm peak average of SST estimates over a narrowed time interval is preferential for paleoclimate reconstruction as it allows for the inclusion of more records of multiple paleotemperature proxies.
Analytic Expressions for the Gravity Gradient Tensor of 3D Prisms with Depth-Dependent Density
NASA Astrophysics Data System (ADS)
Jiang, Li; Liu, Jie; Zhang, Jianzhong; Feng, Zhibing
2017-12-01
Variable-density sources have been paid more attention in gravity modeling. We conduct the computation of gravity gradient tensor of given mass sources with variable density in this paper. 3D rectangular prisms, as simple building blocks, can be used to approximate well 3D irregular-shaped sources. A polynomial function of depth can represent flexibly the complicated density variations in each prism. Hence, we derive the analytic expressions in closed form for computing all components of the gravity gradient tensor due to a 3D right rectangular prism with an arbitrary-order polynomial density function of depth. The singularity of the expressions is analyzed. The singular points distribute at the corners of the prism or on some of the lines through the edges of the prism in the lower semi-space containing the prism. The expressions are validated, and their numerical stability is also evaluated through numerical tests. The numerical examples with variable-density prism and basin models show that the expressions within their range of numerical stability are superior in computational accuracy and efficiency to the common solution that sums up the effects of a collection of uniform subprisms, and provide an effective method for computing gravity gradient tensor of 3D irregular-shaped sources with complicated density variation. In addition, the tensor computed with variable density is different in magnitude from that with constant density. It demonstrates the importance of the gravity gradient tensor modeling with variable density.
Byatt, Nancy; Moore Simas, Tiffany A; Biebel, Kathleen; Sankaran, Padma; Pbert, Lori; Weinreb, Linda; Ziedonis, Douglas; Allison, Jeroan
2017-10-10
This pilot study was designed to inform a larger effectiveness trial by: (1) assessing the feasibility of the PRogram In Support of Moms (PRISM) and our study procedures; and, (2) determining the extent to which PRISM as compared to an active comparison group, the Massachusetts Child Access Psychiatry Program (MCPAP) for Moms alone, improves depression among perinatal women. Four practices were randomized to either PRISM or MCPAP for Moms alone, a state-wide telephonic perinatal psychiatry program. PRISM includes MCPAP for Moms plus implementation assistance with local champions, training, and implementation of office prompts and procedures to enhance depression screening, assessment and treatment. Patients with Edinburgh Postnatal Depression Scales (EPDS) ≥ 10 were recruited during pregnancy, and completed the EPDS and a structured interview at baseline and 3-12 weeks' postpartum. Among MCPAP for Moms alone practices, patients' (n = 9) EPDS scores improved from 15.22 to 10.11 (p = 0.010), whereas in PRISM practices patients' (n = 21) EPDS scores improved from 13.57 to 6.19 (p = 0.001); the between groups difference-of-differences was 2.27 (p = 0.341). PRISM was beneficial for patients, clinicians, and support staff. Both PRISM and MCPAP for Moms alone improve depression symptom severity and the percentage of women with an EPDS >10. The improvement difference between groups was not statistically significant due to limited power associated with small sample size.
Czaja, Sara J; Boot, Walter R; Charness, Neil; Rogers, Wendy A; Sharit, Joseph
2018-05-08
Information and communication technology holds promise in terms of providing support and reducing isolation among older adults. We evaluated the impact of a specially designed computer system for older adults, the Personal Reminder Information and Social Management (PRISM) system. The trial was a multisite randomized field trial conducted at 3 sites. PRISM was compared to a Binder condition wherein participants received a notebook that contained paper content similar to that contained in PRISM. The sample included 300 older adults at risk for social isolation who lived independently in the community (Mage = 76.15 years). Primary outcome measures included indices of social isolation, social support, loneliness, and well-being. Secondary outcome measures included indices of computer proficiency and attitudes toward technology. Data were collected at baseline and at 6 and 12 months post-randomization. The PRISM group reported significantly less loneliness and increased perceived social support and well-being at 6 months. There was a trend indicating a decline in social isolation. Group differences were not maintained at 12 months, but those in the PRISM condition still showed improvements from baseline. There was also an increase in computer self-efficacy, proficiency, and comfort with computers for PRISM participants at 6 and 12 months. The findings suggest that access to technology applications such as PRISM may enhance social connectivity and reduce loneliness among older adults and has the potential to change attitudes toward technology and increase technology self-efficacy.
Tunnel Vision Prismatic Field Expansion: Challenges and Requirements
Apfelbaum, Henry; Peli, Eli
2015-01-01
Purpose No prismatic solution for peripheral field loss (PFL) has gained widespread acceptance. Field extended by prisms has a corresponding optical scotoma at the prism apices. True expansion can be achieved when each eye is given a different view (through visual confusion). We analyze the effects of apical scotomas and binocular visual confusion in different designs to identify constraints on any solution that is likely to meet acceptance. Methods Calculated perimetry diagrams were compared to perimetry with PFL patients wearing InWave channel prisms and Trifield spectacles. Percept diagrams illustrate the binocular visual confusion. Results Channel prisms provide no benefit at primary gaze. Inconsequential extension was provided by InWave prisms, although accessible with moderate gaze shifts. Higher-power prisms provide greater extension, with greater paracentral scotoma loss, but require uncomfortable gaze shifts. Head turns, not eye scans, are needed to see regions lost to the apical scotomas. Trifield prisms provide field expansion at all gaze positions, but acceptance was limited by disturbing effects of central binocular visual confusion. Conclusions Field expansion when at primary gaze (where most time is spent) is needed while still providing unobstructed central vision. Paracentral multiplexing prisms we are developing that superimpose shifted and see-through views may accomplish that. Translational Relevance Use of the analyses and diagramming techniques presented here will be of value when considering prismatic aids for PFL, and could have prevented many unsuccessful designs and the improbable reports we cited from the literature. New designs must likely address the challenges identified here. PMID:26740910
Tunnel Vision Prismatic Field Expansion: Challenges and Requirements.
Apfelbaum, Henry; Peli, Eli
2015-12-01
No prismatic solution for peripheral field loss (PFL) has gained widespread acceptance. Field extended by prisms has a corresponding optical scotoma at the prism apices. True expansion can be achieved when each eye is given a different view (through visual confusion). We analyze the effects of apical scotomas and binocular visual confusion in different designs to identify constraints on any solution that is likely to meet acceptance. Calculated perimetry diagrams were compared to perimetry with PFL patients wearing InWave channel prisms and Trifield spectacles. Percept diagrams illustrate the binocular visual confusion. Channel prisms provide no benefit at primary gaze. Inconsequential extension was provided by InWave prisms, although accessible with moderate gaze shifts. Higher-power prisms provide greater extension, with greater paracentral scotoma loss, but require uncomfortable gaze shifts. Head turns, not eye scans, are needed to see regions lost to the apical scotomas. Trifield prisms provide field expansion at all gaze positions, but acceptance was limited by disturbing effects of central binocular visual confusion. Field expansion when at primary gaze (where most time is spent) is needed while still providing unobstructed central vision. Paracentral multiplexing prisms we are developing that superimpose shifted and see-through views may accomplish that. Use of the analyses and diagramming techniques presented here will be of value when considering prismatic aids for PFL, and could have prevented many unsuccessful designs and the improbable reports we cited from the literature. New designs must likely address the challenges identified here.
Transmission intensity disturbance in a rotating polarizer
NASA Astrophysics Data System (ADS)
Fan, J. Y.; Li, H. X.; Wu, F. Q.
2008-01-01
Random disturbance was observed in transmission intensity in various rotating prism polarizers when they were used in optical systems. As a result, the transmitted intensity exhibited cyclic significant deviation from the Malus cosine-squared law with rotation of prisms. The disturbance spoils the light quality transmitted through the polarizer thus dramatically depresses the accuracies of measurements when the prim polarizers were used in light path. A rigorous model is presented based on the solid basis of multi-beams interference, and theoretical results show good agreement with measured values and also indicate effective method for reducing the disturbance.
Piecewise uniform conduction-like flow channels and method therefor
Cummings, Eric B [Livermore, CA; Fiechtner, Gregory J [Livermore, CA
2006-02-28
A low-dispersion methodology for designing microfabricated conduction channels for on-chip electrokinetic-based systems is presented. The technique relies on trigonometric relations that apply for ideal electrokinetic flows, allowing faceted channels to be designed on chips using common drafting software and a hand calculator. Flows are rotated and stretched along the abrupt interface between adjacent regions with differing permeability. Regions bounded by interfaces form flow "prisms" that can be combined with other designed prisms to obtain a wide range of turning angles and expansion ratios while minimizing dispersion. Designs are demonstrated using two-dimensional numerical solutions of the Laplace equation.
Two simple image slicers for high resolution spectroscopy
NASA Astrophysics Data System (ADS)
Tala, M.; Vanzi, L.; Avila, G.; Guirao, C.; Pecchioli, E.; Zapata, A.; Pieralli, F.
2017-04-01
We present the design, manufacturing, test and performance of two image slicers for high resolution spectroscopy. Based on the classical Bowen-Walraven concept, our slicers allow to make two slices of the image of the input fibre. We introduce the idea of a second fibre that can be cropped in half to reach the same width of the science target fibre and that can be used for simultaneous wavelength reference. The slicers presented are mirror and prism based, respectively. Both devices work within expectation, showing differences mainly in their efficiency. The prism based slicer is the solution that was adopted for the FIDEOS spectrograph, an instrument built by the AIUC for the ESO 1m telescope of La Silla. Test spectra obtained with this instrument are included as examples of a real application of the device.
Alternating prism exposure causes dual adaptation and generalization to a novel displacement
NASA Technical Reports Server (NTRS)
Welch, Robert B.; Bridgeman, Bruce; Anand, Sulekha; Browman, Kaitlin E.
1993-01-01
In two experiments, we examined the hypothesis that repeatedly adapting and readapting to two mutually conflicting sensory environments fosters the development of a separate adaptation to each situation (dual adaptation) as well as an increased ability to adapt to a novel displacement (adaptive generalization). In the preliminary study, subjects alternated between adapting their visuomotor coordination to 30-diopter prismatic displacement and readapting to normal vision. Dual adaptation was observed by the end of 10 alternation cycles. However, an unconfounded test of adaptive generalization was prevented by an unexpected prism-adaptive shift in preexposure baselines for the dual-adapted subjects. In the primary experiment, the subjects adapted and readapted to opposite 15-diopter displacements for a total of 12 cycles. Both dual adaptation and adaptive generalization to a 30-diopter displacement were obtained. These findings may be understood in terms of serial reversal learning and 'learning to learn'.
Variable temperature, variable-gap Otto prism coupler for use in a vacuum environment
NASA Astrophysics Data System (ADS)
Cairns, G. F.; O'Prey, S. M.; Dawson, P.
2000-11-01
The field of surface polariton physics really took off with the prism coupling techniques developed by Kretschmann and Raether, and by Otto. This article reports on the construction and operation of a rotatable, in vacuo, variable temperature, Otto coupler with a coupling gap that can be varied by remote control. The specific design attributes of the system offer additional advantages to those of standard Otto systems of (i) temperature variation (ambient to 85 K), and (ii) the use of a valuable, additional reference point, namely the gap-independent reflectance at the Brewster angle at any given, fixed temperature. The instrument is placed firmly in a historical context of developments in the field. The efficacy of the coupler is demonstrated by sample attenuated total reflectance results on films of platinum, niobium, and yttrium barium copper oxide and on aluminum/gallium arsenide (Al/GaAs) Schottky diode structures.
Campbell, David L.; Watts, Raymond D.
1978-01-01
Program listing, instructions, and example problems are given for 12 programs for the interpretation of geophysical data, for use on Hewlett-Packard models 67 and 97 programmable hand-held calculators. These are (1) gravity anomaly over 2D prism with = 9 vertices--Talwani method; (2) magnetic anomaly (?T, ?V, or ?H) over 2D prism with = 8 vertices?Talwani method; (3) total-field magnetic anomaly profile over thick sheet/thin dike; (4) single dipping seismic refractor--interpretation and design; (5) = 4 dipping seismic refractors--interpretation; (6) = 4 dipping seismic refractors?design; (7) vertical electrical sounding over = 10 horizontal layers--Schlumberger or Wenner forward calculation; (8) vertical electric sounding: Dar Zarrouk calculations; (9) magnetotelluric planewave apparent conductivity and phase angle over = 9 horizontal layers--forward calculation; (10) petrophysics: a.c. electrical parameters; (11) petrophysics: elastic constants; (12) digital convolution with = 10-1ength filter.
Comment on Schuster's Technique for Focusing the Prism Spectrometer.
ERIC Educational Resources Information Center
Beynon, John
1991-01-01
Discussed is the physics that underpins Schuster's technique for obtaining a parallel light beam for use in various prism and grating experiments. Basic physics concepts using geometrical optics of prism, together with elementary differential calculus are explained as well as the mechanics of Schuster's technique. (KR)
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a...
Mapping Atmospheric Moisture Climatologies across the Conterminous United States
Daly, Christopher; Smith, Joseph I.; Olson, Keith V.
2015-01-01
Spatial climate datasets of 1981–2010 long-term mean monthly average dew point and minimum and maximum vapor pressure deficit were developed for the conterminous United States at 30-arcsec (~800m) resolution. Interpolation of long-term averages (twelve monthly values per variable) was performed using PRISM (Parameter-elevation Relationships on Independent Slopes Model). Surface stations available for analysis numbered only 4,000 for dew point and 3,500 for vapor pressure deficit, compared to 16,000 for previously-developed grids of 1981–2010 long-term mean monthly minimum and maximum temperature. Therefore, a form of Climatologically-Aided Interpolation (CAI) was used, in which the 1981–2010 temperature grids were used as predictor grids. For each grid cell, PRISM calculated a local regression function between the interpolated climate variable and the predictor grid. Nearby stations entering the regression were assigned weights based on the physiographic similarity of the station to the grid cell that included the effects of distance, elevation, coastal proximity, vertical atmospheric layer, and topographic position. Interpolation uncertainties were estimated using cross-validation exercises. Given that CAI interpolation was used, a new method was developed to allow uncertainties in predictor grids to be accounted for in estimating the total interpolation error. Local land use/land cover properties had noticeable effects on the spatial patterns of atmospheric moisture content and deficit. An example of this was relatively high dew points and low vapor pressure deficits at stations located in or near irrigated fields. The new grids, in combination with existing temperature grids, enable the user to derive a full suite of atmospheric moisture variables, such as minimum and maximum relative humidity, vapor pressure, and dew point depression, with accompanying assumptions. All of these grids are available online at http://prism.oregonstate.edu, and include 800-m and 4-km resolution data, images, metadata, pedigree information, and station inventory files. PMID:26485026
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hui; Barbieri, Christopher E.; He, Jintang
Speckle-type POZ protein (SPOP) is an E3 ubiquitin ligase adaptor protein that functions as a potential tumor suppressor, and SPOP mutations have been identified in ~10% of human prostate cancers. However, it remains unclear if mutant SPOP proteins can be utilized as biomarkers for early detection, diagnosis, prognosis or targeted therapy of prostate cancer. Moreover, the SPOP mutation sites are distributed in a relatively short region where multiple lysine residues, posing significant challenges for bottom-up proteomics analysis of the SPOP mutations. To address this issue, PRISM (high-pressure, high-resolution separations coupled with intelligent selection and multiplexing)-SRM (selected reaction monitoring) mass spectrometrymore » assays have been developed for quantifying wild-type SPOP protein and 11 prostate cancer-derived SPOP mutations. Despite inherent limitations due to amino acid sequence constraints, all the PRISM-SRM assays developed using Arg-C digestion showed a linear dynamic range of at least two orders of magnitude, with limits of quantification range from 0.1 to 1 fmol/μg of total protein in the cell lysate. Applying these SRM assays to analyze HEK293T cells with and without expression of the three most frequent SPOP mutations in prostate cancer (Y87N, F102C or F133V) led to confident detection of all three SPOP mutations in corresponding positive cell lines but not in the negative cell lines. Expression of the F133V mutation and wild-type SPOP was at much lower levels compared to that of F102C and Y87N mutations; however, at present it is unknown if this also affects the activity of the SPOP protein. In summary, PRISM-SRM enables multiplexed, isoform-specific detection of mutant SPOP proteins in cell lysates, which holds great potential in biomarker development for prostate cancer.« less
System-wide identification of wild-type SUMO-2 conjugation sites
Hendriks, Ivo A.; D'Souza, Rochelle C.; Chang, Jer-Gung; Mann, Matthias; Vertegaal, Alfred C. O.
2015-01-01
SUMOylation is a reversible post-translational modification (PTM) regulating all nuclear processes. Identification of SUMOylation sites by mass spectrometry (MS) has been hampered by bulky tryptic fragments, which thus far necessitated the use of mutated SUMO. Here we present a SUMO-specific protease-based methodology which circumvents this problem, dubbed Protease-Reliant Identification of SUMO Modification (PRISM). PRISM allows for detection of SUMOylated proteins as well as identification of specific sites of SUMOylation while using wild-type SUMO. The method is generic and could be widely applied to study lysine PTMs. We employ PRISM in combination with high-resolution MS to identify SUMOylation sites from HeLa cells under standard growth conditions and in response to heat shock. We identified 751 wild-type SUMOylation sites on endogenous proteins, including 200 dynamic SUMO sites in response to heat shock. Thus, we have developed a method capable of quantitatively studying wild-type mammalian SUMO at the site-specific and system-wide level. PMID:26073453
Nurses across borders: displaced Russian and Soviet nurses after World War I and World War II.
Grant, Susan
2014-01-01
Russian and Soviet nurse refugees faced myriad challenges attempting to become registered nurses in North America and elsewhere after the World War II. By drawing primarily on International Council of Nurses refugee files, a picture can be pieced together of the fate that befell many of those women who left Russia and later the Soviet Union because of revolution and war in the years after 1917. The history of first (after World War I) and second (after World War II) wave émigré nurses, integrated into the broader historical narrative, reveals that professional identity was just as important to these women as national identity. This became especially so after World War II, when Russian and Soviet refugee nurses resettled in the West. Individual accounts become interwoven on an international canvas that brings together a wide range of personal experiences from women based in Russia, the Soviet Union, China, Yugoslavia, Canada, the United States, and elsewhere. The commonality of experience among Russian nurses as they attempted to establish their professional identities highlights, through the prism of Russia, the importance of the history of the displaced nurse experience in the wider context of international migration history.
Erosion Control Techniques on Forest Road Cutslopes and Fillslopes in North Alabama
Johnny M. Grace
1999-01-01
Road cutslopes and fillslopes account for approximately 50 percent of the total road disturbance area on steep terrain and contribute as much as 60 percent of sediment from forest roads. The significance of erosion control techniques on these vulnerable components of the road prism has become evident in recent years. A study to gain a better understanding of erosion...
NASA Astrophysics Data System (ADS)
Garcia-Molina, Rafael; del Mazo, Alejandro; Velasco, Santiago
2018-01-01
We present a simple and cheap experimental setup that clearly shows how the colors of the white light spectrum after passing a prism do not recombine when emerging from an identical second prism, as it is still found in many references.
ERIC Educational Resources Information Center
Garcia-Molina, Rafael; del Mazo, Alejandro; Velasco, Santiago
2018-01-01
We present a simple and cheap experimental setup that clearly shows how the colors of the white light spectrum after passing a prism do not recombine when emerging from an identical second prism, as it is still found in many references.
Optical power splitter for splitting high power light
English, R.E. Jr.; Christensen, J.J.
1995-04-18
An optical power splitter for the distribution of high-power light energy has a plurality of prisms arranged about a central axis to form a central channel. The input faces of the prisms are in a common plane which is substantially perpendicular to the central axis. A beam of light which is substantially coaxial to the central axis is incident on the prisms and at least partially strikes a surface area of each prism input face. The incident beam also partially passes through the central channel. 5 figs.
Strongly-Refractive One-Dimensional Photonic Crystal Prisms
NASA Technical Reports Server (NTRS)
Ting, David Z. (Inventor)
2004-01-01
One-dimensional (1D) photonic crystal prisms can separate a beam of polychromatic electromagnetic waves into constituent wavelength components and can utilize unconventional refraction properties for wavelength dispersion over significant portions of an entire photonic band rather than just near the band edges outside the photonic band gaps. Using a ID photonic crystal simplifies the design and fabrication process and allows the use of larger feature sizes. The prism geometry broadens the useful wavelength range, enables better optical transmission, and exhibits angular dependence on wavelength with reduced non-linearity. The properties of the 1 D photonic crystal prism can be tuned by varying design parameters such as incidence angle, exit surface angle, and layer widths. The ID photonic crystal prism can be fabricated in a planar process, and can be used as optical integrated circuit elements.
Development of salt production technology using prism greenhouse method
NASA Astrophysics Data System (ADS)
Guntur, G.; Jaziri, A. A.; Prihanto, A. A.; Arisandi, D. M.; Kurniawan, A.
2018-01-01
The main problem of salt production in Indonesia is low productivity and quality because the technology used commonly by Indonesian salt farmers is traditional method. This research aims to increase production of salt by using the prism greenhouse method. The prism greenhouse method is a salt production system with a combination of several salt production technologies, including geomembrane, threaded filter, and prism greenhouse technology. This research method used descriptive method. The results of this study were the productivity increased threefold, and the quality of salt produced also increased in terms of the content of NaCl from 85% to 95%. In addition, salt production with the prism greenhouse method has several advantages, such as faster harvest time, weather resistance, easy to use, and higher profit than traditional methods.
Volckmann, Pierre; Jacquin-Courtois, Sophie
2016-01-01
Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations. PMID:27668094
NASA Astrophysics Data System (ADS)
Garcia, M.; Peters-Lidard, C. D.; Eylander, J. B.; Daly, C.; Gibson, W.; Tian, Y.; Zeng, J.; Kato, H.
2008-05-01
Collaborations between the Air Force Weather Agency (AFWA), the Hydrological Sciences Branch at NASA-GSFC, and the PRISM Group at Oregon State University have led to improvements in the processing of meteorological forcing inputs for the NASA-GSFC Land Information System (LIS; Kumar et al. 2006), a sophisticated framework for LSM operation and model coupling experiments. Efforts at AFWA toward the production of surface hydrometeorological products are currently in transition from the legacy Agricultural Meteorology modeling system (AGRMET) to use of the LIS framework and procedures. Recent enhancements to meteorological input processing for application to land surface models in LIS include the assimilation of climate-based information for the spatial interpolation and downscaling of precipitation fields. Climatological information included in the LIS- based downscaling procedure for North America is provided by a monthly high-resolution PRISM (Daly et al. 1994, 2002; Daly 2006) dataset based on a 30-year analysis period. The combination of these sources and methods attempts to address the strengths and weaknesses of available legacy products, objective interpolation methods, and the PRISM knowledge-based methodology. All of these efforts are oriented on an operational need for timely estimation of spatial precipitation fields at adequate spatial resolution for customer dissemination and near-real-time simulations in regions of interest. This work focuses on value added to the AGRMET precipitation product by the inclusion of high-quality climatological information on a monthly time scale. The AGRMET method uses microwave-based satellite precipitation estimates from various polar-orbiting platforms (NOAA POES and DMSP), infrared-based estimates from geostationary platforms (GOES, METEOSAT, etc.), related cloud analysis products, and surface gauge observations in a complex and hierarchical blending process. Results from processing of the legacy AGRMET precipitation products over the U.S. using LIS-based methods for downscaling, both with and without climatological factors, are evaluated against high-resolution monthly analyses using the PRISM knowledge- based method (Daly et al. 2002) over a 4-year period. It is demonstrated that the incorporation of climatological information in a downscaling procedure can significantly enhance the accuracy, and potential utility, of AFWA precipitation products for customer applications, especially over mountainous terrain as in the western U.S.
3D holographic polymer photonic crystal for superprism application
NASA Astrophysics Data System (ADS)
Chen, Jiaqi; Jiang, Wei; Chen, Xiaonan; Wang, Li; Zhang, Sasa; Chen, Ray T.
2007-02-01
Photonic crystal based superprism offers a new way to design new optical components for beam steering and DWDM application. 3D photonic crystals are especially attractive as they could offer more control of the light beam based on the needs. A polygonal prism based holographic fabrication method has been demonstrated for a three-dimensional face-centered-cubic (FCC)-type submicron polymer photonic crystal using SU8 as the photo-sensitive material. Therefore antivibration equipment and complicated optical alignment system are not needed and the requirement for the coherence of the laser source is relaxed compared with the traditional holographic setup. By changing the top-cut prism structure, the polarization of the laser beam, the exposure and development conditions we can achieve different kinds of triclinic or orthorhombic photonic crystals on demand. Special fabrication treatments have been introduced to ensure the survivability of the fabricated large area (cm2) nano-structures. Scanning electron microscopy and diffraction results proved the good uniformity of the fabricated structures. With the proper design of the refraction prism we have achieved a partial bandgap for S+C band (1460-1565nm) in the [111] direction. The transmission and reflection spectra obtained by Fourier transform infrared spectroscopy (FTIR) are in good agreement with simulated band structure. The superprism effects around 1550nm wavelength for the fabricated 3D polymer photonic crystal have been theoretically calculated and such effects can be used for beam steering purpose.
[Do prisms according to Hans-Joachim Haase improve stereoacuity?].
Kromeier, Miriam; Schmitt, Christina; Bach, Michael; Kommerell, Guntram
2002-06-01
The "Measuring and Correcting Methodology" after H.-J. Haase (MKH) aims at converting "fixation disparity" into bicentral fixation, using prismatic spectacles. In the context of the MKH, fixation disparity is diagnosed by a series of subjective tests. According to H.-J. Haase, a long-standing fixation disparity can lead to "disparate correspondence" between the central areas of both retinae, which consolidates the fixation disparity and gradually converts a "young" into an "old fixation disparity". In "old fixation disparity" it is thought that bicentral fixation does not occur anymore, so that stereoacuity is impaired. However, prismatic spectacles can, according to H.-J. Haase, restitute bicentral fixation and consequently improve stereoacuity, even in some cases of "old fixation disparity". Ten non-strabismic subjects with a visual acuity of >/= 1.0 in both eyes were examined. It turned out that all ten had, according to MKH, a "disparate correspondence", 5 subjects with a "young" and 5 with an "old fixation disparity". According to the MKH, a correcting prism was determined. All 10 subjects underwent the automatic Freiburg Stereoacuity Test, without and with the MKH-prism. Without the MKH-prism, the stereoscopic threshold ranged between 1.5 and 14.5 arcsec. With the MKH-prism, the values were not significantly different. Stereoacuity ranged between good and excellent in the 5 subjects with "young" as well as in the 5 subjects with "old fixation disparity". The MKH-prism did not improve the stereoacuity in any of the subjects. These results cast doubt on Haase's assertion that an "old fixation disparity" implies a reduced stereoacuity. Hence, the premise for a benefit of the MKH-prism with respect of stereoacuity is not substantiated. In the 5 subjects with a "young fixation disparity", the good stereoacuity is consistent with Haase's theory, so that a benefit of the MKH-prism for stereoacuity was not expected. In previous studies, stereoacuity was found to be better with the MKH-prism than without it. These studies are questionable since learning with repeated testing was not taken into account. We conclude that there is no sound evidence for the assumption that the MKH-prism can improve stereoacuity.
Landward vergence in accretionary prism, evidence for frontal propagation of earthquakes?
NASA Astrophysics Data System (ADS)
cubas, Nadaya; Souloumiac, Pauline
2016-04-01
Landward vergence in accretionary wedges is rare and have been described at very few places: along the Cascadia subduction zone and more recently along Sumatra where the 2004 Mw 9.1 Sumatra-Andaman event and the 2011 tsunami earthquake occurred. Recent studies have suggested a relation between landward thrust faults and frontal propagation of earthquakes for the Sumatra subduction zone. The Cascadia subduction zone is also known to have produced in 1700 a Mw9 earthquake with a large tsunami across the Pacific. Based on mechanical analysis, we propose to investigate if specific frictional properties could lead to a landward sequence of thrusting. We show that landward thrust requires very low effective friction along the megathrust with a rather high internal effective friction. We also show that landward thrust appears close to the extensional critical limit. Along Cascadia and Sumatra, we show that to get landward vergence, the effective basal friction has to be lower than 0.08. This very low effective friction is most likely due to high pore pressure. This high pore pressure could either be a long-term property or due to dynamic effects such as thermal pressurization. The fact that landward vergence appears far from the compressional critical limit favors a dynamic effect. Landward vergence would then highlight thermal pressurization due to occasional or systematic propagation of earthquakes to the trench. As a consequence, the vergence of thrusts in accretionary prism could be used to improve seismic and tsunamigenic risk assessment.
Microstructural features of carious human enamel imaged with back-scattered electrons.
Pearce, E I; Nelson, D G
1989-02-01
We have used back-scattered electrons (BE) in the scanning electron microscope to produce mineral density images of enamel. Flat surfaces of artificially-carious enamel, softened in an intra-oral experiment, and naturally-carious (white spot) enamel were polished to a high gloss with diamond lapping compound, rendering them almost featureless by secondary electron scanning electron microscopy. They were then examined at 10 to 30 kV in a Philips 505 instrument fitted with a 4-quadrant BE detector. Study of surfaces prepared approximately parallel to the natural surface showed that mineral was lost from both prism core and the interprismatic region, leaving a thin mineral-rich rim at the prism periphery. The same lesions viewed longitudinally on a surface prepared perpendicular to the natural surface showed mineral-rich bands at the prism margins in the outer enamel. Near the advancing front of the lesion, the prism junctions were widened and the prism cores sometimes hypermineralized. Natural lesions sectioned in the prism long axis showed features previously seen with other techniques, e.g., cross-striations and striae of Retzius, but in much greater detail. Mineral enrichment at the prism periphery in the lesion body and a widening of the prism junction at the advancing fronts of lesions in permanent teeth were most obvious. Calculations showed that with an accelerating voltage of 30 kV, the images reflected mineral density up to 4 microns beneath the surface. BE microscopy produces a high-resolution image of mineral loss or gain in carious enamel, with relatively easy sample preparation.
Controllable Sonar Lenses and Prisms Based on ERFs
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph; Sherrit, Stewart; Chang, Zensheu; Bao, Xiaoqi; Paustian, Iris; Lopes, Joseph; Folds, Donald
2004-01-01
Sonar-beam-steering devices of the proposed type would contain no moving parts and would be considerably smaller and less power-hungry, relative to conventional multiple-beam sonar arrays. The proposed devices are under consideration for installation on future small autonomous underwater vehicles because the sizes and power demands of conventional multiple-beam arrays are excessive, and motors used in single-beam mechanically scanned systems are also not reliable. The proposed devices would include a variety of electrically controllable acoustic prisms, lenses, and prism/lens combinations both simple and compound. These devices would contain electrorheological fluids (ERFs) between electrodes. An ERF typically consists of dielectric particles floating in a dielectric fluid. When an electric field is applied to the fluid, the particles become grouped into fibrils aligned in rows, with a consequent increase in the viscosity of the fluid and a corresponding increase in the speed of sound in the fluid. The change in the speed of sound increases with an increase in the applied electric field. By thus varying the speed of sound, one varies the acoustic index of refraction, analogously to varying the index of refraction of an optical lens or prism. In the proposed acoustic devices, this effect would be exploited to control the angles of refraction of acoustic beams, thereby steering the beams and, in the case of lenses, controlling focal lengths.
Prism-coupled Cherenkov phase-matched terahertz wave generation using a DAST crystal.
Suizu, Koji; Shibuya, Takayuki; Uchida, Hirohisa; Kawase, Kodo
2010-02-15
Terahertz (THz) wave generation based on nonlinear frequency conversion is a promising method for realizing a tunable monochromatic high-power THz-wave source. Unfortunately, many nonlinear crystals have strong absorption in the THz frequency region. This limits efficient and widely tunable THz-wave generation. The Cherenkov phase-matching method is one of the most promising techniques for overcoming these problems. Here, we propose a prism-coupled Cherenkov phase-matching (PCC-PM) method, in which a prism with a suitable refractive index at THz frequencies is coupled to a nonlinear crystal. This has the following advantages. Many crystals can be used as THz-wave emitters; the phase-matching condition inside the crystal does not have to be observed; the absorption of the crystal does not prevent efficient generation of radiation; and pump sources with arbitrary wavelengths can be employed. Here we demonstrate PCC-PM THz-wave generation using the organic crystal 4-dimethylamino-N-metyl-4-stilbazolium tosylate (DAST) and a Si prism coupler. We obtain THz-wave radiation with tunability of approximately 0.1 to 10 THz and with no deep absorption features resulting from the absorption spectrum of the crystal. The obtained spectra did not depend on the pump wavelength in the range 1300 to 1450 nm. This simple technique shows promise for generating THz radiation using a wide variety of nonlinear crystals.
Investigating First Year Elementary Mathematics Teacher Education Students' Knowledge of Prism
ERIC Educational Resources Information Center
Bozkurt, Ali; Koc, Yusuf
2012-01-01
The purpose of this study was to investigate first year elementary mathematics teacher education students' knowledge of prism. For this goal, the participants were asked to define the geometric concept of prism. The participants were 158 first year elementary mathematics teacher education students from a public university in Southern Turkey. The…
Left to Right: Representational Biases for Numbers and the Effect of Visuomotor Adaptation
ERIC Educational Resources Information Center
Loftus, Andrea M.; Nicholls, Michael E. R.; Mattingley, Jason B.; Bradshaw, John L.
2008-01-01
Adaptation to right-shifting prisms improves left neglect for mental number line bisection. This study examined whether adaptation affects the mental number line in normal participants. Thirty-six participants completed a mental number line task before and after adaptation to either: left-shifting prisms, right-shifting prisms or control…
The formation of ammonium cobalt (II) phosphate was utilized to synthesize unprecedented 3D structures of Co3O4, triangular prisms and trunk-like structures, via a self-supported and organics-free method. The length of a triangular side of the prepared 3D triangular prisms is ~1...
PRISM Climate Group, Oregon State U
FAQ PRISM Climate Data The PRISM Climate Group gathers climate observations from a wide range of monitoring networks, applies sophisticated quality control measures, and develops spatial climate datasets to reveal short- and long-term climate patterns. The resulting datasets incorporate a variety of modeling
Genomes to natural products PRediction Informatics for Secondary Metabolomes (PRISM)
Skinnider, Michael A.; Dejong, Chris A.; Rees, Philip N.; Johnston, Chad W.; Li, Haoxin; Webster, Andrew L. H.; Wyatt, Morgan A.; Magarvey, Nathan A.
2015-01-01
Microbial natural products are an invaluable source of evolved bioactive small molecules and pharmaceutical agents. Next-generation and metagenomic sequencing indicates untapped genomic potential, yet high rediscovery rates of known metabolites increasingly frustrate conventional natural product screening programs. New methods to connect biosynthetic gene clusters to novel chemical scaffolds are therefore critical to enable the targeted discovery of genetically encoded natural products. Here, we present PRISM, a computational resource for the identification of biosynthetic gene clusters, prediction of genetically encoded nonribosomal peptides and type I and II polyketides, and bio- and cheminformatic dereplication of known natural products. PRISM implements novel algorithms which render it uniquely capable of predicting type II polyketides, deoxygenated sugars, and starter units, making it a comprehensive genome-guided chemical structure prediction engine. A library of 57 tailoring reactions is leveraged for combinatorial scaffold library generation when multiple potential substrates are consistent with biosynthetic logic. We compare the accuracy of PRISM to existing genomic analysis platforms. PRISM is an open-source, user-friendly web application available at http://magarveylab.ca/prism/. PMID:26442528
Porous Ni-Co-Mn oxides prisms for high performance electrochemical energy storage
NASA Astrophysics Data System (ADS)
Zhao, Jianbo; Li, Man; Li, Junru; Wei, Chengzhen; He, Yuyue; Huang, Yixuan; Li, Qiaoling
2017-12-01
Porous Ni-Co-Mn oxides prisms have been successfully synthesized via a facile route. The process involves the preparation of nickel-cobalt-manganese acetate hydroxide by a simple co-precipitation method and subsequently the thermal treatment. The as-synthesized Ni-Co-Mn oxides prisms had a large surface area (96.53 m2 g-1) and porous structure. As electrode materials for supercapacitors, porous Ni-Co-Mn oxides prisms showed a high specific capacitance of 1623.5 F g-1 at 1.0 A g-1. Moreover, the porous Ni-Co-Mn oxides prisms were also employed as positive electrode materials to assemble flexible solid-state asymmetric supercapacitors. The resulting flexible device had a maximum volumetric energy density (0.885 mW h cm-3) and power density (48.9 mW cm-3). Encouragingly, the flexible device exhibited good cycling stability with only about 2.2% loss after 5000 charge-discharge cycles and excellent mechanical stability. These results indicate that porous Ni-Co-Mn oxides prisms have the promising application in high performance electrochemical energy storage.
PRISM Spectrograph Optical Design
NASA Technical Reports Server (NTRS)
Chipman, Russell A.
1995-01-01
The objective of this contract is to explore optical design concepts for the PRISM spectrograph and produce a preliminary optical design. An exciting optical configuration has been developed which will allow both wavelength bands to be imaged onto the same detector array. At present the optical design is only partially complete because PRISM will require a fairly elaborate optical system to meet its specification for throughput (area*solid angle). The most complex part of the design, the spectrograph camera, is complete, providing proof of principle that a feasible design is attainable. This camera requires 3 aspheric mirrors to fit inside the 20x60 cm cross-section package. A complete design with reduced throughput (1/9th) has been prepared. The design documents the optical configuration concept. A suitable dispersing prism material, CdTe, has been identified for the prism spectrograph, after a comparison of many materials.
NASA Astrophysics Data System (ADS)
Hamada, Y.; Kitamura, M.; Yamada, Y.; Sanada, Y.; Moe, K.; Hirose, T.
2016-12-01
In-situ rock properties in/around seismogenic zone in an accretionary prism are key parameters to understand the development mechanisms of an accretionary prism, spatio-temporal variation of stress state, and so on. For the purpose of acquiring continuous-depth-profile of in-situ formation strength in an accretionary prism, here we propose the new method to evaluate the in-situ rock strength using drilling performance property. Drilling parameters are inevitably obtained by any drilling operation even in the non-coring intervals or at challenging environment where core recovery may be poor. The relationship between the rock properties and drilling parameters has been proposed by previous researches [e.g. Teale 1964]. We introduced the relationship theory of Teale [1964], and developed a converting method to estimate in-situ rock strength without depending on uncertain parameters such as weight on bit (WOB). Specifically, we first calculated equivalent specific toughness (EST) which represents gradient of the relationship between Torque energy and volume of penetration at arbitrary interval (in this study, five meters). Then the EST values were converted into strength using the drilling parameters-rock strengths correlation obtained by Karasawa et al. [2002]. This method was applied to eight drilling holes in the Site C0002 of IODP NanTroSEIZE in order to evaluate in-situ rock strength in shallow to deep accretionary prism. In the shallower part (0 - 300 mbsf), the calculated strength shows sharp increase up to 20 MPa. Then the strength has approximate constant value to 1500 mbsf without significant change even at unconformity around 1000 mbsf (boundary between forearc basin and accretionary prism). Below that depth, value of the strength gradually increases with depth up to 60 MPa at 3000 mbsf with variation between 10 and 80 MPa. Because the calculated strength is across approximately the same lithology, the increase trend can responds to the rock strength. This strength-depth curve correspond reasonably well with the strength data of core and cutting samples collected from hole C0002N and C0002P [Kitamura et al., 2016 AGU]. These results show the validity of the method evaluating in-situ strength from the drilling parameters.
Heat transfer to four fineness-ratio-1.6 hexagonal prisms with various corner radii at Mach 6
NASA Technical Reports Server (NTRS)
Hunt, J. L.
1972-01-01
An investigation was conducted in the Langley 20-inch Mach 6 tunnel to define the aerodynamic heat transfer to the radioisotope fuel cask (heat source) of the SNAP-19/Pioneer power system. The shape of the SNAP-19/Pioneer heat source is that of a hexagonal prism with flat ends; the fineness ratio, based on maximum (edge to edge) diameter, is 1.61. Phase-change-paint heat-transfer data and schlieren photographs were obtained on four possible 1/2-scale entry configurations of the SNAP-19/Pioneer heat source. Tests were conducted over a wide range of attitudes and at nominal Reynolds numbers, based on the length of the unablated configuration, of 33,000; 84,000; and 2,200,000.
Schintu, Selene; Pisella, Laure; Jacobs, Stéphane; Salemme, Romeo; Reilly, Karen T; Farnè, Alessandro
2014-01-01
Rightward prism adaptation has been shown to ameliorate visuospatial biases in right brain-damaged patients with neglect, and a single session of prism adaptation can lead to improvements that last up to several hours. Leftward prism adaptation in neurologically healthy individuals induces neglect-like biases in visuospatial tasks. The duration of these effects in healthy individuals, typically assumed to be ephemeral, has never been investigated. Here we assessed the time-course of the adaptation-induced modifications in a classical perceptual line bisection task that was repeatedly administered for approximately 40min after a single session of adaptation to either a leftward or rightward prismatic deviation. Consistent with previous reports, only adaptation to leftward-deviating prisms induced a visuospatial shift on perceptual line bisection judgments. The typical pattern of pseudoneglect was counteracted by a rightward shift in midline judgments, which became significant between 5 and 10 min after adaptation, fluctuated between being significant or not several times in the 40 min following adaptation, and was present as late as 35 min. In contrast, the sensorimotor aftereffect was present immediately after adaptation to both rightward and leftward deviating prisms, decayed initially then remained stable until 40 min. These results demonstrate that both the sensorimotor and visuospatial effects last for at least 35 min, but that the visuospatial shift needs time to fully develop and fluctuates. By showing that the effects of prism adaptation in the undamaged brain are not ephemeral, these findings reveal the presence of another, so-far neglected dimension in the domain of the cognitive effects induced by prism adaptation, namely time. The prolonged duration of the induced visuospatial shift, previously considered to be a feature of prism adaptation unique to brain-damaged subjects, also applies to the normal brain. © 2013 Published by Elsevier Ltd.
Hashimoto, Yuji; Honda, Takeru; Matsumura, Ken; Nakao, Makoto; Soga, Kazumasa; Katano, Kazuhiko; Yokota, Takanori; Mizusawa, Hidehiro; Nagao, Soichi; Ishikawa, Kinya
2015-01-01
The cerebellum plays important roles in motor coordination and learning. However, motor learning has not been quantitatively evaluated clinically. It thus remains unclear how motor learning is influenced by cerebellar diseases or aging, and is related with incoordination. Here, we present a new application for testing human cerebellum-dependent motor learning using prism adaptation. In our paradigm, the participant wearing prism-equipped goggles touches their index finger to the target presented on a touchscreen in every trial. The whole test consisted of three consecutive sessions: (1) 50 trials with normal vision (BASELINE), (2) 100 trials wearing the prism that shifts the visual field 25° rightward (PRISM), and (3) 50 trials without the prism (REMOVAL). In healthy subjects, the prism-induced finger-touch error, i.e., the distance between touch and target positions, was decreased gradually by motor learning through repetition of trials. We found that such motor learning could be quantified using the "adaptability index (AI)", which was calculated by multiplying each probability of [acquisition in the last 10 trials of PRISM], [retention in the initial five trials of REMOVAL], and [extinction in the last 10 trials of REMOVAL]. The AI of cerebellar patients less than 70 years old (mean, 0.227; n = 62) was lower than that of age-matched healthy subjects (0.867, n = 21; p < 0.0001). While AI did not correlate with the magnitude of dysmetria in ataxic patients, it declined in parallel with disease progression, suggesting a close correlation between the impaired cerebellar motor leaning and the dysmetria. Furthermore, AI decreased with aging in the healthy subjects over 70 years old compared with that in the healthy subjects less than 70 years old. We suggest that our paradigm of prism adaptation may allow us to quantitatively assess cerebellar motor learning in both normal and diseased conditions.
Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Sun, Xuefei; Gao, Yuqian
2013-07-05
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a medianmore » CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM-SRM quantification of low-abundance cellular proteins in systems biology studies as well as candidate biomarkers in biofluids.« less
Hashimoto, Yuji; Honda, Takeru; Matsumura, Ken; Nakao, Makoto; Soga, Kazumasa; Katano, Kazuhiko; Yokota, Takanori; Mizusawa, Hidehiro; Nagao, Soichi; Ishikawa, Kinya
2015-01-01
The cerebellum plays important roles in motor coordination and learning. However, motor learning has not been quantitatively evaluated clinically. It thus remains unclear how motor learning is influenced by cerebellar diseases or aging, and is related with incoordination. Here, we present a new application for testing human cerebellum-dependent motor learning using prism adaptation. In our paradigm, the participant wearing prism-equipped goggles touches their index finger to the target presented on a touchscreen in every trial. The whole test consisted of three consecutive sessions: (1) 50 trials with normal vision (BASELINE), (2) 100 trials wearing the prism that shifts the visual field 25° rightward (PRISM), and (3) 50 trials without the prism (REMOVAL). In healthy subjects, the prism-induced finger-touch error, i.e., the distance between touch and target positions, was decreased gradually by motor learning through repetition of trials. We found that such motor learning could be quantified using the “adaptability index (AI)”, which was calculated by multiplying each probability of [acquisition in the last 10 trials of PRISM], [retention in the initial five trials of REMOVAL], and [extinction in the last 10 trials of REMOVAL]. The AI of cerebellar patients less than 70 years old (mean, 0.227; n = 62) was lower than that of age-matched healthy subjects (0.867, n = 21; p < 0.0001). While AI did not correlate with the magnitude of dysmetria in ataxic patients, it declined in parallel with disease progression, suggesting a close correlation between the impaired cerebellar motor leaning and the dysmetria. Furthermore, AI decreased with aging in the healthy subjects over 70 years old compared with that in the healthy subjects less than 70 years old. We suggest that our paradigm of prism adaptation may allow us to quantitatively assess cerebellar motor learning in both normal and diseased conditions. PMID:25785588
Update on strabismus and amblyopia.
Campos, E C
1995-01-01
This review analyzes progress in the field of infantile strabismus and amblyopia. Only works which are of clinical interest have been reviewed. A brief survey is provided also of subjects matter of international debate, as surgery for accommodative esotropia, the prism adaptation test and the use of sectors for amblyopia treatment. Mention is made of new developments in the field which are not yet applicable to clinical practice. Finally, progress in the approach towards ocular nystagmus is considered as well.
An Astronomical Test of CCD Photometric Precision
NASA Technical Reports Server (NTRS)
Koch, David G.; Dunham, Edward W.; Borucki, William J.; Jenkins, Jon M.
2001-01-01
Ground-based differential photometry is limited to a precision of order 10(exp -3) because of atmospheric effects. A space-based photometer should be limited only by the inherent instrument precision and shot noise. Laboratory tests have shown that a precision of order 10-5 is achievable with commercially available charged coupled devices (CCDs). We have proposed to take this one step further by performing measurements at a telescope using a Wollaston prism as a beam splitter First-order atmospheric effects (e.g., extinction) will appear to be identical in the two images of each star formed by the prism and will be removed in the data analysis. This arrangement can determine the precision that is achievable under the influence of second-order atmospheric effects (e.g., variable point-spread function (PSF) from seeing). These telescopic observations will thus provide a lower limit to the precision that can be realized by a space-based differential photometer.
PRISM Software: Processing and Review Interface for Strong‐Motion Data
Jones, Jeanne M.; Kalkan, Erol; Stephens, Christopher D.; Ng, Peter
2017-01-01
A continually increasing number of high‐quality digital strong‐motion records from stations of the National Strong Motion Project (NSMP) of the U.S. Geological Survey, as well as data from regional seismic networks within the United States, calls for automated processing of strong‐motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong‐motion records. When used without AQMS, PRISM provides batch‐processing capabilities. The PRISM software is platform independent (coded in Java), open source, and does not depend on any closed‐source or proprietary software. The software consists of two major components: a record processing engine composed of modules for each processing step, and a review tool, which is a graphical user interface for manual review, edit, and processing. To facilitate use by non‐NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand‐alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible to accommodate implementation of new processing techniques. All the computing features have been thoroughly tested.
Iverson, N.R.; Hooyer, T.S.; Fischer, U.H.; Cohen, D.; Moore, P.L.; Jackson, M.; Lappegard, G.; Kohler, J.
2007-01-01
To avoid some of the limitations of studying soft-bed processes through boreholes, a prism of simulated till (1.8 m ?? 1.6 m ?? 0.45 m) with extensive instrumentation was constructed in a trough blasted in the rock bed of Engabreen, a temperate glacier in Norway. Tunnels there provide access to the bed beneath 213 m of ice. Pore-water pressure was regulated in the prism by pumping water to it. During experiments lasting 7-12 days, the glacier regelated downward into the prism to depths of 50-80 mm, accreting ice-infiltrated till at rates predicted by theory. During periods of sustained high pore-water pressure (70-100% of overburden), ice commonly slipped over the prism, due to a water layer at the prism surface. Deformation of the prism was activated when this layer thinned to a sub-millimeter thickness. Shear strain in the till was pervasive and decreased with depth. A model of slip by ploughing of ice-infiltrated till across the prism surface accounts for the slip that occurred when effective pressure was sufficiently low or high. Slip at low effective pressures resulted from water-layer thickening that increased non-linearly with decreasing effective pressure. If sufficiently widespread, such slip over soft glacier beds, which involves no viscous deformation resistance, may instigate abrupt increases in glacier velocity.
NASA Astrophysics Data System (ADS)
Church, Philip; Borribanbunpotkat, Kiatchai; Trickey, Evan; Iles, Peter; Sekerka, Mike
2014-06-01
Neptec has developed a family of obscurant-penetrating 3D laser scanners called OPAL 2.0 that are being adapted for rotorcraft platforms. Neptec and Boeing have been working on an integrated system utilizing the OPAL LiDAR to support operations in degraded visual environments. OPAL scanners incorporate Neptec's patented obscurantpenetrating LiDAR technology which was extensively tested in controlled dust environments and helicopters for brownout mitigation. The OPAL uses a scanning mechanism based on the Risley prism pair. Data acquisition rates can go as high as 200kHz for ranges within 200m and 25kHz for ranges exceeding 200m. The scan patterns are created by the rotation of two prisms under independent motor control. The geometry and material properties of the prisms will define the conical field-of-view of the sensor, which can be set up to 120 degrees. Through detailed simulations and analysis of mission profiles, the system can be tailored for applications to rotorcrafts. Examples of scan patterns and control schemes based on these simulations will be provided along with data density predictions versus acquisition time for applicable DVE scenarios. Preliminary 3D data acquired in clear and obscurant conditions will be presented.
A 'learning-by-doing' treatment planning tutorial for medical physicists.
Meyer, J; Hartmann, B; Kalet, I
2009-06-01
A framework for a tutorial for treatment planning in radiation oncology physics was developed, based on the University of Washington treatment planning system Prism. The tutorial is aimed at students in Medical Physics to accompany the lectures on treatment planning to enhance their theoretical knowledge. A web-based layout was chosen to allow independent work of the students. The tutorial guides the students through three different learning modules, designed mainly to enhance their understanding of the processes involved in treatment planning but also to learn the specific features of a modern treatment planning system. Each of the modules contains four units, with the aim to introduce the relevant Prism features, practice skills in different tasks and finally check the learning outcomes with a challenge and a self-scoring quiz. A survey for students' feedback completes the tutorial. Various tools and learning methods help to create an interactive, appealing learning environment, in which the emphasis is shifted from teacher-centred to student-centred learning paradigms. In summary, Prism lends itself well for educational purposes. The tutorial covers all main aspects of treatment planning. In its current form the tutorial is self-contained but still adjustable and expandable. The tutorial can be made available upon request to the authors.
Calibration of the Wedge Prism
Charles B. Briscoe
1957-01-01
Since the introduction of plotless cruising in this country by Grosenbaugh and the later suggestion of using a wedge prism as an angle gauge by Bruce this method of determining basal area has been widely adopted in the South. One of the factors contributing to the occasionally unsatisfactory results obtained is failure to calibrate the prism used. As noted by Bruce the...
2010-08-01
In this work, a novel electro - optic beam switch (EOBS) is designed, fabricated and demonstrated. The EOBS presented in this work is designed for a...consists of a series of electronically controlled prisms fabricated by ferroelectric domain inversion in an electro - optic crystal wafer. The prisms are
Multibeam collimator uses prism stack
NASA Technical Reports Server (NTRS)
Minott, P. O.
1981-01-01
Optical instrument creates many divergent light beams for surveying and machine element alignment applications. Angles and refractive indices of stack of prisms are selected to divert incoming laser beam by small increments, different for each prism. Angles of emerging beams thus differ by small, precisely-controlled amounts. Instrument is nearly immune to vibration, changes in gravitational force, temperature variations, and mechanical distortion.
A Longitudinal Study of Prism Adaptation in Infants from Six to Nine Months of Age.
ERIC Educational Resources Information Center
McDonnell, Paul M.; Abraham, Wayne C.
1981-01-01
Confirms that aftereffects of prism adaptation can be obtained in infants between 5 and 9 months of age and that the magnitude of these aftereffects is comparable to those found in adult studies. Evidence of a shift in hand preference toward the direction of prism displacement was replicated. (Author/RH)
1991-06-05
2 Prism Dye Amplifiers .................................................................................. 2 Axicon...carried out under this project. PRISM DYE AMPLIFIERS A first effort was devoted to setting up an amplifier system for the output of a short pulse dye laser...For amplification up to pulse energies of approximately 500 p.J/pulse we chose three stages of prism amplifier cells, with diameters of 1 m, 3 mm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sokolov, Viktor I; Panchenko, Vladislav Ya; Seminogov, V N
2012-08-31
A method is proposed for measuring the refractive index gradient n(z) in nonuniformly thick dielectric films. The method is based on the excitation of waveguide modes in a film using the prism coupling technique and on the calculation of n(z) and film thickness H{sub f} with the help of the angular positions of the TE or TM modes. The method can be used for an arbitrary shape of the index modulation over the film thickness in the limit of a small gradient [{Delta} n(z)/n(z) || 1]. (laser applications and other topics in quantum electronics)
[When is the prescription of prismatic eyeglasses reasonable?].
Kommerell, G
2014-03-01
Prismatic glasses are used to deflect rays of light. In ophthalmology, prisms are mainly used to correct double vision caused by strabismus which is acquired after early childhood. In congenital or infantile strabismus, the image of the deviated eye is usually suppressed so that double vision does not occur and prismatic glasses are not indicated. Latent strabismus is very common and only rarely leads to double vision or asthenopic symptoms so that correction with prismatic glasses is only indicated in exceptional cases. The "Measuring and Correcting Methodology after H.-J. Haase" is based on flawed assumptions, and therefore can not be recommended for the prescription of prisms.
Probabilistic Priority Message Checking Modeling Based on Controller Area Networks
NASA Astrophysics Data System (ADS)
Lin, Cheng-Min
Although the probabilistic model checking tool called PRISM has been applied in many communication systems, such as wireless local area network, Bluetooth, and ZigBee, the technique is not used in a controller area network (CAN). In this paper, we use PRISM to model the mechanism of priority messages for CAN because the mechanism has allowed CAN to become the leader in serial communication for automobile and industry control. Through modeling CAN, it is easy to analyze the characteristic of CAN for further improving the security and efficiency of automobiles. The Markov chain model helps us to model the behaviour of priority messages.
NASA Astrophysics Data System (ADS)
Reznicek, R.
The present conference on flow visualization encompasses methods exploiting tracing particles, surface tracing methods, methods exploiting the effects of streaming fluid on passing radiation/field, computer-aided flow visualization, and applications to fluid mechanics, aerodynamics, flow devices, shock tubes, and heat/mass transfer. Specific issues include visualizing velocity distribution by stereo photography, dark-field Fourier quasiinterferometry, speckle tomography of an open flame, a fast eye for real-time image analysis, and velocity-field determination based on flow-image analysis. Also addressed are flows around rectangular prisms with oscillating flaps at the leading edges, the tomography of aerodynamic objects, the vapor-screen technique applied to a delta-wing aircraft, flash-lamp planar imaging, IR-thermography applications in convective heat transfer, and the visualization of marangoni effects in evaporating sessile drops.
XeCl excimer laser with new prism resonator configurations and its performance characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benerji, N. S., E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in; Singh, A.; Varshnay, N.
2015-07-15
New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configurationmore » with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.« less
XeCl excimer laser with new prism resonator configurations and its performance characteristics.
Benerji, N S; Singh, A; Varshnay, N; Singh, Bijendra
2015-07-01
New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configuration with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.
Büchi, S; Straub, S; Schwager, U
2010-12-01
Although there is much talk about shared decision making and individualized goal setting, there is a lack of knowledge and knowhow in their realization in daily clinical practice. There is a lack in tools for easy applicable tools to ameliorate person-centred individualized goal setting processes. In three selected psychiatric inpatients the semistructured, theory driven use of PRISM (Pictorial Representation of Illness and Self Measure) in patients with complex psychiatric problems is presented and discussed. PRISM sustains a person-centred individualized process of goal setting and treatment and reinforces the active participation of patients. The process of visualisation and synchronous documentation is validated positively by patients and clinicians. The visual goal setting requires 30 to 45 minutes. In patients with complex psychiatric illness PRISM was used successfully to ameliorate individual goal setting. Specific effects of PRISM-visualisation are actually evaluated in a randomized controlled trial.
Direct view zoom scope with single focal plane and adaptable reticle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bagwell, Brett
A direct view telescopic sight includes objective lens, eyepiece, and prism erector assemblies. The objective lens assembly is mounted to receive light of an image from an object direction and direct the light along an optical path. The eyepiece assembly is mounted to receive the light along the optical path and to emit the light of the image along an eye-ward direction. The prism erector assembly is positioned between the objective lens and eyepiece assemblies and includes first and second prism elements through which the optical path passes. The first and second prism elements invert the image. A reticle elementmore » is disposed on or adjacent to a surface of one of the first or second prism elements to combine a reticle on the image. The image is brought into focus at only a single focal plane between the objective lens and eyepiece assemblies at a given time.« less
von Huene, Roland E.; Scholl, D. W.
1991-01-01
At ocean margins where two plates converge, the oceanic plate sinks or is subducted beneath an upper one topped by a layer of terrestrial crust. This crust is constructed of continental or island arc material. The subduction process either builds juvenile masses of terrestrial crust through arc volcanism or new areas of crust through the piling up of accretionary masses (prisms) of sedimentary deposits and fragments of thicker crustal bodies scraped off the subducting lower plate. At convergent margins, terrestrial material can also bypass the accretionary prism as a result of sediment subduction, and terrestrial matter can be removed from the upper plate by processes of subduction erosion. Sediment subduction occurs where sediment remains attached to the subducting oceanic plate and underthrusts the seaward position of the upper plate's resistive buttress (backstop) of consolidated sediment and rock. Sediment subduction occurs at two types of convergent margins: type 1 margins where accretionary prisms form and type 2 margins where little net accretion takes place. At type 2 margins (???19,000 km in global length), effectively all incoming sediment is subducted beneath the massif of basement or framework rocks forming the landward trench slope. At accreting or type 1 margins, sediment subduction begins at the seaward position of an active buttress of consolidated accretionary material that accumulated in front of a starting or core buttress of framework rocks. Where small-to-mediumsized prisms have formed (???16,300 km), approximately 20% of the incoming sediment is skimmed off a detachment surface or decollement and frontally accreted to the active buttress. The remaining 80% subducts beneath the buttress and may either underplate older parts of the frontal body or bypass the prism entirely and underthrust the leading edge of the margin's rock framework. At margins bordered by large prisms (???8,200 km), roughly 70% of the incoming trench floor section is subducted beneath the frontal accretionary body and its active buttress. In rounded figures the contemporary rate of solid-volume sediment subduction at convergent ocean margins (???43,500 km) is calculated to be 1.5 km3/yr. Correcting type 1 margins for high rates of terrigenous seafloor sedimentation during the past 30 m.y. or so sets the long-term rate of sediment subduction at 1.0 km3/yr. The bulk of the subducted material is derived directly or indirectly from continental denudation. Interstitial water currently expulsed from accreted and deeply subducted sediment and recycled to the ocean basins is estimated at 0.9 km3/yr. The thinning and truncation caused by subduction erosion of the margin's framework rock and overlying sedimentary deposits have been demonstrated at many convergent margins but only off northern Japan, central Peru, and northern Chile has sufficient information been collected to determine average or long-term rates, which range from 25 to 50 km3/m.y. per kilometer of margin. A conservative long-term rate applicable to many sectors of convergent margins is 30 km3/km/m.y. If applied to the length of type 2 margins, subduction erosion removes and transports approximately 0.6 km3/yr of upper plate material to greater depths. At various places, subduction erosion also affects sectors of type 1 margins bordered by small- to medium-sized accretionary prisms (for example, Japan and Peru), thus increasing the global rate by possibly 0.5 km3/yr to a total of 1.1 km3/yr. Little information is available to assess subduction erosion at margins bordered by large accretionary prisms. Mass balance calculations allow assessments to be made of the amount of subducted sediment that bypasses the prism and underthrusts the margin's rock framework. This subcrustally subducted sediment is estimated at 0.7 km3/yr. Combined with the range of terrestrial matter removed from the margin's rock framework by subduction erosion, the global volume of subcrustally subducted materia
NDE application of ultrasonic tomography to a full-scale concrete structure.
Choi, Hajin; Popovics, John S
2015-06-01
Newly developed ultrasonic imaging technology for large concrete elements, based on tomographic reconstruction, is presented. The developed 3-D internal images (velocity tomograms) are used to detect internal defects (polystyrene foam and pre-cracked concrete prisms) that represent structural damage within a large steel reinforced concrete element. A hybrid air-coupled/contact transducer system is deployed. Electrostatic air-coupled transducers are used to generate ultrasonic energy and contact accelerometers are attached on the opposing side of the concrete element to detect the ultrasonic pulses. The developed hybrid testing setup enables collection of a large amount of high-quality, through-thickness ultrasonic data without surface preparation to the concrete. The algebraic reconstruction technique is used to reconstruct p-wave velocity tomograms from the obtained time signal data. A comparison with a one-sided ultrasonic imaging method is presented for the same specimen. Through-thickness tomography shows some benefit over one-sided imaging for highly reinforced concrete elements. The results demonstrate that the proposed through-thickness ultrasonic technique shows great potential for evaluation of full-scale concrete structures in the field.
A test of point-sampling in northern hardwoods
Dale S. Solomon
1975-01-01
Plot- and point-sampling were compared with a complete inventory of two different stands of northern hardwoods. Prisms with basal-area factors of 5, 10, 20, 30, and 40 and a ¼-acre plot were used. Only the 5-factor prism gave a significantly different estimate. Therefore, a prism factor of 10 or greater is suggested for use in northern hardwoods.
A bi-prism interferometer for hard x-ray photons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isakovic, A.F.; Siddons, D.; Stein, A.
2010-04-06
Micro-fabricated bi-prisms have been used to create an interference pattern from an incident hard X-ray beam, and the intensity of the pattern probed with fluorescence from a 30 nm-thick metal film. Maximum fringe visibility exceeded 0.9 owing to the nano-sized probe and the choice of single-crystal prism material. A full near-field analysis is necessary to describe the fringe field intensities, and the transverse coherence lengths were extracted at APS beamline 8-ID-I. It is also shown that the maximum number of fringes is dependent only on the complex refractive index of the prism material.
PRISM software—Processing and review interface for strong-motion data
Jones, Jeanne M.; Kalkan, Erol; Stephens, Christopher D.; Ng, Peter
2017-11-28
Rapidly available and accurate ground-motion acceleration time series (seismic recordings) and derived data products are essential to quickly providing scientific and engineering analysis and advice after an earthquake. To meet this need, the U.S. Geological Survey National Strong Motion Project has developed a software package called PRISM (Processing and Review Interface for Strong-Motion data). PRISM automatically processes strong-motion acceleration records, producing compatible acceleration, velocity, and displacement time series; acceleration, velocity, and displacement response spectra; Fourier amplitude spectra; and standard earthquake-intensity measures. PRISM is intended to be used by strong-motion seismic networks, as well as by earthquake engineers and seismologists.
Hendrix, James Lee
2001-05-08
A Porro prism and a light polarizer are combined in a single optical element termed a Hendrix Prism. The design provides retro-reflection of incoming light of a predetermined polarization in a direction anti-parallel to the direction of light incidence, while reflecting undesired light, i.e., that having a polarization orthogonal to the predetermined polarization, from the surface of the light polarizer. The undesired light is reflected in a direction that does not interfere with the intended operation of the device in which the Hendrix Prism is installed yet provides feedback to the system in which it is used.
Analytical models for the groundwater tidal prism and associated benthic water flux
King, Jeffrey N.; Mehta, Ashish J.; Dean, Robert G.
2010-01-01
The groundwater tidal prism is defined as the volume of water that inundates a porous medium, forced by one tidal oscillation in surface water. The pressure gradient that generates the prism acts on the subterranean estuary. Analytical models for the groundwater tidal prism and associated benthic flux are presented. The prism and flux are shown to be directly proportional to porosity, tidal amplitude, and the length of the groundwater wave; flux is inversely proportional to tidal period. The duration of discharge flux exceeds the duration of recharge flux over one tidal period; and discharge flux continues for some time following low tide. Models compare favorably with laboratory observations and are applied to a South Atlantic Bight study area, where tide generates an 11-m3 groundwater tidal prism per m of shoreline, and drives 81 m3 s −1 to the study area, which describes 23% of an observational estimate. In a marine water body, the discharge component of any oscillatory benthic water flux is submarine groundwater discharge. Benthic flux transports constituents between groundwater and surface water, and is a process by which pollutant loading and saltwater intrusion may occur in coastal areas.
Fu, Tao; Wang, Jing; Levin, Moran; Su, Qing; Li, Dongguo; Li, Junfa
2015-01-01
Purpose. To measure the changes in fusional vergence in Chinese children with intermittent exotropia (IXT) and the association with the control of IXT. Methods. Ninety-two patients with IXT (8-15 years old) were compared with 86 controls. Exodeviation control was evaluated using the Revised Newcastle Control Score. Angle of deviation was measured using prism and alternate cover testing at distance and near. Fusional vergence was measured using prism bar and synoptophore. This study was registered with ChiCTR-RCC-13003920. Results. Using prism bar, convergence break points were lower whereas divergence break points were higher in children with IXT at distance (P < 0.001) and near (P < 0.001) compared with controls. There was no significant difference in mean divergence amplitudes between the two groups when testing using a synoptophore (P = 0.53). In children with IXT, the distance between recovery point and break point in both convergence (distance: P = 0.02; near: P = 0.02) and divergence (distance: P < 0.001; near: P < 0.001) was larger than controls when detected by prism bar and synoptophore (convergence: P = 0.005; divergence: P = 0.006). Conclusions. Children with IXT have reduced convergence amplitudes as detected by both prism bar and synoptophore.
Genomes to natural products PRediction Informatics for Secondary Metabolomes (PRISM).
Skinnider, Michael A; Dejong, Chris A; Rees, Philip N; Johnston, Chad W; Li, Haoxin; Webster, Andrew L H; Wyatt, Morgan A; Magarvey, Nathan A
2015-11-16
Microbial natural products are an invaluable source of evolved bioactive small molecules and pharmaceutical agents. Next-generation and metagenomic sequencing indicates untapped genomic potential, yet high rediscovery rates of known metabolites increasingly frustrate conventional natural product screening programs. New methods to connect biosynthetic gene clusters to novel chemical scaffolds are therefore critical to enable the targeted discovery of genetically encoded natural products. Here, we present PRISM, a computational resource for the identification of biosynthetic gene clusters, prediction of genetically encoded nonribosomal peptides and type I and II polyketides, and bio- and cheminformatic dereplication of known natural products. PRISM implements novel algorithms which render it uniquely capable of predicting type II polyketides, deoxygenated sugars, and starter units, making it a comprehensive genome-guided chemical structure prediction engine. A library of 57 tailoring reactions is leveraged for combinatorial scaffold library generation when multiple potential substrates are consistent with biosynthetic logic. We compare the accuracy of PRISM to existing genomic analysis platforms. PRISM is an open-source, user-friendly web application available at http://magarveylab.ca/prism/. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
A comparative study of spherical and flat-Earth geopotential modeling at satellite elevations
NASA Technical Reports Server (NTRS)
Parrott, M. H.; Hinze, W. J.; Braile, L. W.; Vonfrese, R. R. B.
1985-01-01
Flat-Earth modeling is a desirable alternative to the complex spherical-Earth modeling process. These methods were compared using 2 1/2 dimensional flat-earth and spherical modeling to compute gravity and scalar magnetic anomalies along profiles perpendicular to the strike of variably dimensioned rectangular prisms at altitudes of 150, 300, and 450 km. Comparison was achieved with percent error computations (spherical-flat/spherical) at critical anomaly points. At the peak gravity anomaly value, errors are less than + or - 5% for all prisms. At 1/2 and 1/10 of the peak, errors are generally less than 10% and 40% respectively, increasing to these values with longer and wider prisms at higher altitudes. For magnetics, the errors at critical anomaly points are less than -10% for all prisms, attaining these magnitudes with longer and wider prisms at higher altitudes. In general, in both gravity and magnetic modeling, errors increase greatly for prisms wider than 500 km, although gravity modeling is more sensitive than magnetic modeling to spherical-Earth effects. Preliminary modeling of both satellite gravity and magnetic anomalies using flat-Earth assumptions is justified considering the errors caused by uncertainties in isolating anomalies.
NASA Astrophysics Data System (ADS)
Steckler, M. S.; Grall, C.; Seeber, L.; Betka, P. M.; Mondal, D. R.; Akhter, S. H.
2016-12-01
The Bengal Basin is the outcome of the superposition of the heavily-sedimented passive margin of India being overthrust both by the IndoBurma accretionary prism from the east and the Shillong Plateau from the north. In response to the India-Asia collision, the remnant ocean between the Lower Cretaceous passive margin of India and the advancing Sunda subduction system has received an immense load of Himalayan sediment. This influx has prograded the shelf edge of the passive margin 300-400 km from the Hinge Zone in the Eocene, prior to the collision, to its current position. The delta coevolved with the now up to 250-km wide accretionary prism of the IndoBurma subduction zone that overthrusts it. The newest element is the Late Pliocene-Quaternary rise of the Shillong anticlinorium on the north side of the Bengal Basin. Shillong overthrusts the Bengal Basin, forming the Sylhet Basin foredeep, and is overthrust by the prism. Shillong represents the beginning of a forward jump of the Himalayas to the Indian passive margin hinge zone as it approached within a flexural wavelength of the mountains. GPS indicates 7 mm/y of N-S convergence in eastern Shillong where total relief reaches 5 km. The superposition of overlapping tectonic elements makes it difficult to estimate flexural rigidity from the basin shape or gravity field. The flexural subsidence of the Sylhet foredeep has downwarped and buried the frontal part of the foldbelt in this region. We therefore estimate flexural rigidities using a thermomechanical model based on the sediment and crustal structure and available thermal data. Receiver functions, local S-to-P converted phases, and seismic reflection data provide constraints on the crustal structure, and on the dip of the Dauki Fault bounding Shillong. We also consider the possibility of volcanically-thickened crust in the basin due to the 90 East Ridge plume. We use both 2-D finite difference and 2-D finite element models (ADELI) to model the flexure associated with the loads through time. The observed gravity anomalies, along with seismic reflections profiles, are used to constrain the models. Flexural rigidities vary from high values in the Indian craton to low (<30 km) in the Bengal Basin. Relatively low sedimentation rates in the Sylhet Basin may be due to the interaction of the Shillong flexure and the foldbelt advance.
2015-11-01
beam splitter , and an arrangement of polarising prisms and waveplates to measure the diffraction pattern resulting from uni- form laser beams in...cornercube retroreflectors identified in the current satellite design are found to allow for a significant variation in the reflected beam width. The...Surface quality 60-40 Housing tolerance OD:† +0/− 0.5 mm H: ±0.25 mm Beam -angle tolerance 3 arcsec Substrate N-BK7 Coating Internal silver Figure 2: Design
A beam splitter of natural light guiding system based on dichroic prism for ecological illumination
NASA Astrophysics Data System (ADS)
Li, Yu-Chi; Chen, Yi-Yung; Whang, Allen Jong-Woei
2009-08-01
In thremmatology, many researches focus on ecological illumination for improving the growing speed of animal or plant. According to the Trichromatic theory, any specific color can be made up of red, green, and blue light. Sunlight has full spectrum so it is the most applicable source. A Natural Light Guiding System includes collecting, transmitting, and lighting parts. In our research, we would like to design a beam splitter in the transmitting part to separate the sunlight into red, green, and blue light for ecological illumination. We use high pass and low pass dichroic coatings in a prism, called dichroic prism, to be the beam splitter to separate the wavelength. For measuring the spectra of the exit beams, we build a space with the Natural Light Guiding System. In the space, the spectra of sunlight outside and inside the space and the exit beams of the beam splitter are measured. Finally, we use prismatic structure to design the beam splitter, and optimize the surface of the element with aspheric surface and Fresnel surface to reduce the beam angle of exit light.
Jing, Lei; Wang, Yao; Zhao, Huifu; Ke, Hongliang; Wang, Xiaoxun; Gao, Qun
2017-06-10
In order to meet the requirements of uniform illumination for optical palm/fingerprint instruments and overcome the shortcomings of the poor uniform illumination on the working plane of the optical palm/fingerprint prism, a novel secondary optical lens with a free-form surface, compact structure, and high uniformity is presented in this paper. The design of the secondary optical lens is based on emission properties of the near-infrared light-emitting diode (LED) and basic principles of non-imaging optics, especially considering the impact of the thickness of the prism in the design. Through the numerical solution of Snell's law in geometric optics, we obtain the profile of the free-form surface of the lens. Using the optical software TracePro, we trace and simulate the illumination system. The results show that the uniformity is 89.8% on the working plane of the prism, and the test results show that the actual uniformity reaches 85.7% in the experiment, which provides an effective way for realizing a highly uniform illumination system with high-power near-infrared LED.
Evaluating bacterial gene-finding HMM structures as probabilistic logic programs.
Mørk, Søren; Holmes, Ian
2012-03-01
Probabilistic logic programming offers a powerful way to describe and evaluate structured statistical models. To investigate the practicality of probabilistic logic programming for structure learning in bioinformatics, we undertook a simplified bacterial gene-finding benchmark in PRISM, a probabilistic dialect of Prolog. We evaluate Hidden Markov Model structures for bacterial protein-coding gene potential, including a simple null model structure, three structures based on existing bacterial gene finders and two novel model structures. We test standard versions as well as ADPH length modeling and three-state versions of the five model structures. The models are all represented as probabilistic logic programs and evaluated using the PRISM machine learning system in terms of statistical information criteria and gene-finding prediction accuracy, in two bacterial genomes. Neither of our implementations of the two currently most used model structures are best performing in terms of statistical information criteria or prediction performances, suggesting that better-fitting models might be achievable. The source code of all PRISM models, data and additional scripts are freely available for download at: http://github.com/somork/codonhmm. Supplementary data are available at Bioinformatics online.
A Self-Assembled Trigonal Prismatic Molecular Vessel for Catalytic Dehydration Reactions in Water.
Das, Paramita; Kumar, Atul; Howlader, Prodip; Mukherjee, Partha Sarathi
2017-09-12
A water-soluble Pd 6 trigonal prism (A) was synthesized by two-component coordination-driven self-assembly of a Pd II 90° acceptor with a tetraimidazole donor. The walls of the prism are constructed by three conjugated aromatic building blocks, which means that the confined pocket of the prism is hydrophobic. In addition to the hydrophobic cavity, large product egress windows make A an ideal molecular vessel to catalyze otherwise challenging pseudo-multicomponent dehydration reactions in its confined nanospace in aqueous medium. This study is an attempt at selective generation of the intermediate tetraketones and xanthenes by fine-tuning the reaction conditions employing a supramolecular molecular vessel. Moreover, either poor or no yield of the dehydrated products in the absence of A under similar reaction conditions supports the ability of the confined space of the barrel to promote such reactions in water. Furthermore, we focused on the rigidification of the tetraphenylethylene-based tetraimidazole unit anchored within the Pd II coordination architecture; enabling counter-anion dependent aggregation induced emission in the presence of water. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Pérez, D.; Miñano, J. C.; Benítez, P.; Muñoz, F.; Mohedano, R.
2005-08-01
A novel photovoltaic concentrator has been developed in the framework of the European project "High efficiency silicon solar cells concentrator". In this project, front-contacted silicon solar cell have also been designed and manufactured by the project leader (the French LETI). This silicon cell concept is potentially capable to perform well (24% efficiency has been predicted) for much higher concentration levels than the back-contacted cells (and, of course, than the two-side contacted cells). The concentrator is formed by one lens of squared contour with flat entry surface and large-facet Fresnel exit surface, and a secondary that encapsulates the solar cell. On the contrary to the conventional Fresnel lens plus nonimaging secondary concentrators, the primary and secondary are designed simultaneously, leading to better concentration-acceptance angle product without compromise with the compactness. The grid lines in the front-contacted cells are aluminium prisms (which contact the p+ and n+ emitters, alternatively), acting as a linear cone concentrator that concentrates Cg =1.52× in the cross sectional dimension of the prisms. The secondary concentrator has a refractive rotational symmetric top surface that is crossed with two linear flow-line TIR mirror. Then, in the cross section normal to the aluminium prisms, the secondary provides a 2D concentration of Cg =12×, while in the cross section parallel to the prisms it provides a 2D concentration of Cg =24.16× as the grid lines in this dimension. Therefore, the cell is rectangular (1:2.08 aspect ratio), being the grid lines parallel to the shorter rectangle side. The total 3D geometrical concentration is 24.16×(12×1.52) = 455× for the square aperture and rectangular cell, and gets a design acceptance angle α=+/-1.8 degrees. Injection moulded prototypes are have been manufactured and measured, proving an optical efficiency of 79%. Computer modelling of the concentrator performance will also be presented.
NASA Technical Reports Server (NTRS)
Hooker, Stanford B. (Editor); Zibordi, Giuseppe; Berthon, Jean-Francois; Bailey, Sean W.; Pietras, Christophe M.; Firestone, Elaine R. (Editor)
2000-01-01
This report documents the scientific activities that took place at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea off the coast of Italy from 2-6 August 1999. The ultimate objective of the field campaign was to evaluate the capabilities of a new instrument called the SeaWiFS Photometer Revision for Incident Surface Measurements (SeaPRISM). SeaPRISM is based on a CE-318 sun photometer made by CIMEL Electronique (Paris, France). The CE-318 is an automated, robotic system which measures the direct sun irradiance plus the sky radiance in the sun plane and in the almucantar plane. The data are transmitted over a satellite link, and this remote operation capability has made the device very useful for atmospheric measurements. The revision to the CE-318 that makes the instrument potentially useful for SeaWiFS calibration and validation activities is to include a capability for measuring the radiance leaving the sea surface in wavelengths suitable for the determination of chlorophyll a concentration. The initial evaluation of this new capability involved above- and in-water measurement protocols. An intercomparison of the water-leaving radiances derived from SeaPRISM and an in-water system showed the overall spectral agreement was approximately 8.6%, but the blue-green channels intercompared at the 5% level. A blue-green band ratio comparison was at the 4% level.
Mechanical and hydraulic properties of Nankai accretionary prism sediments: Effect of stress path
NASA Astrophysics Data System (ADS)
Kitajima, Hiroko; Chester, Frederick M.; Biscontin, Giovanna
2012-10-01
We have conducted triaxial deformation experiments along different loading paths on prism sediments from the Nankai Trough. Different load paths of isotropic loading, uniaxial strain loading, triaxial compression (at constant confining pressure, Pc), undrained Pc reduction, drained Pc reduction, and triaxial unloading at constant Pc, were used to understand the evolution of mechanical and hydraulic properties under complicated stress states and loading histories in accretionary subduction zones. Five deformation experiments were conducted on three sediment core samples for the Nankai prism, specifically from older accreted sediments at the forearc basin, underthrust slope sediments beneath the megasplay fault, and overthrust Upper Shikoku Basin sediments along the frontal thrust. Yield envelopes for each sample were constructed based on the stress paths of Pc-reduction using the modified Cam-clay model, and in situ stress states of the prism were constrained using the results from the other load paths and accounting for horizontal stress. Results suggest that the sediments in the vicinity of the megasplay fault and frontal thrust are highly overconsolidated, and thus likely to deform brittle rather than ductile. The porosity of sediments decreases as the yield envelope expands, while the reduction in permeability mainly depends on the effective mean stress before yield, and the differential stress after yield. An improved understanding of sediment yield strength and hydromechanical properties along different load paths is necessary to treat accurately the coupling of deformation and fluid flow in accretionary subduction zones.
Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source
NASA Astrophysics Data System (ADS)
Lim, Yiheng; Yatagai, Toyohiko; Otani, Yukitoshi
2016-04-01
An ultra-high resolution spectral domain optical coherence tomography (SD-OCT) was developed using a cost-effective supercontinuum laser. A spectral filter consists of a dispersive prism, a cylindrical lens and a right-angle prism was built to transmit the wavelengths in range 680-940 nm to the OCT system. The SD-OCT has achieved 1.9 μm axial resolution and the sensitivity was estimated to be 91.5 dB. A zero-crossing fringes matching method which maps the wavelengths to the pixel indices of the spectrometer was proposed for the OCT spectral calibration. A double sided foam tape as a static sample and the tip of a middle finger as a biological sample were measured by the OCT. The adhesive and the internal structure of the foam of the tape were successfully visualized in three dimensions. Sweat ducts was clearly observed in the OCT images at very high resolution. To the best of our knowledge, this is the first demonstration of ultra-high resolution visualization of sweat duct by OCT.