Prism adaptation by mental practice.
Michel, Carine; Gaveau, Jérémie; Pozzo, Thierry; Papaxanthis, Charalambos
2013-09-01
The prediction of our actions and their interaction with the external environment is critical for sensorimotor adaptation. For instance, during prism exposure, which deviates laterally our visual field, we progressively correct movement errors by combining sensory feedback with forward model sensory predictions. However, very often we project our actions to the external environment without physically interacting with it (e.g., mental actions). An intriguing question is whether adaptation will occur if we imagine, instead of executing, an arm movement while wearing prisms. Here, we investigated prism adaptation during mental actions. In the first experiment, participants (n = 54) performed arm pointing movements before and after exposure to the optical device. They were equally divided into six groups according to prism exposure: Prisms-Active, Prisms-Imagery, Prisms-Stationary, Prisms-Stationary-Attention, No Conflict-Prisms-Imagery, No Prisms-Imagery. Adaptation, measured by the difference in pointing errors between pre-test and post-test, occurred only in Prisms-Active and Prisms-Imagery conditions. The second experiment confirmed the results of the first experiment and further showed that sensorimotor adaptation was mainly due to proprioceptive realignment in both Prisms-Active (n = 10) and Prisms-Imagery (n = 10) groups. In both experiments adaptation was greater following actual than imagined pointing movements. The present results are the first demonstration of prism adaptation by mental practice under prism exposure and they are discussed in terms of internal forward models and sensorimotor plasticity. Copyright © 2012 Elsevier Ltd. All rights reserved.
Comparison of near fusional vergence ranges with rotary prisms and with prism bars.
Goss, David A; Becker, Emily
2011-02-01
Common methods for determination of fusional vergence ranges make use of rotary prisms in the phoropter or prism bars out of the phoropter. This study compared near fusional vergence ranges with rotary prisms with those with prism bars. Fifty young adults served as subjects. Odd-numbered subjects had rotary prism vergences performed before prism bar vergences. For even-numbered subjects, prism bar vergences were done first. Base-in (BI) vergences were done before base-out (BO) vergences with both rotary prisms and prism bars. A coefficient of agreement was calculated by multiplying the standard deviation of the individual subject differences between rotary prisms and prism bars by 1.96, to approximate the range within which the 2 tests would agree 95% of the time. The lowest coefficient of agreement was 7.3Δ for the BI recovery. The others were high, ranging from 15.4Δ for the BO recovery to 19.5Δ for the BO break. Fusional vergence ranges determined by prism bars out of the phoropter cannot be used interchangeably with those determined by phoropter rotary prisms for the purpose of follow-up on individual patients or for the purpose of comparison with norms. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
1975-08-01
prism adjustment screw 12 - 45° prism adjustment lockscrew 13-45° prism 14 - Porro prism 15 - Collimating telescope X-axis adjustment lockscrew...4) 16 - Q-switch tilt adjustment screw 17 - Q-switch tilt adjustment lockscrew (4) 18 - Porro prism adjustment nut (3) 19 - Porro prism mounting...is increased by several orders of magnitude. "Q" switch technology has progressed from rotating prisms or mirrors to electro-optical (E/0
Harbauer, Gregor; Ring, Mariann; Schuetz, Christopher; Andreae, Andreas; Haas, Sebastian
2013-01-01
The PRISM-S task was developed at the Crisis Intervention Center (KIZ) Winterthur, Switzerland, to enable an assessment of the degree of suicidality in less than 5 minutes with a simple, visual instrument. Comparison of validity and clinical use of the new PRISM-S task with other instruments known as "gold standards". Quantitative pilot study enlisting 100 inpatients admitted to the KIZ, aged 15-42 years. Patients' suicidality was assessed by the PRISM-S task during the first clinical interview and compared to data obtained by standardized suicidality instruments. The patients completed the PRISM-S task in 2 to 5 minutes without difficulty. Data show significant positive correlations between the suicidality as assessed by PRISM-S and the gold standards, i.e., DSI-SS (r = 0.59, N = 65, p < .0001). There is no strong evidence that PRISM-S is useful for outpatients or in other settings. The experiences gained with outpatients/patients with other disorders are promising but have not been systematically evaluated. The results do not rely on a randomized design. The sample consists of persons coming to the crisis intervention center. PRISM-S offers a brief, easy-to-administer, and valid method to assess patients' suicidality. The simple instruction facilitates its use in other languages and other cultures as well. The acceptance by patients and health professionals was good, with no one refusing to complete the task.
Optical switch using Risley prisms
Sweatt, William C.; Christenson, Todd R.
2003-04-15
An optical switch using Risley prisms and rotary microactuators to independently rotate the wedge prisms of each Risley prism pair is disclosed. The optical switch comprises an array of input Risley prism pairs that selectively redirect light beams from a plurality of input ports to an array of output Risley prism pairs that similarly direct the light beams to a plurality of output ports. Each wedge prism of each Risley prism pair can be independently rotated by a variable-reluctance stepping rotary microactuator that is fabricated by a multi-layer LIGA process. Each wedge prism can be formed integral to the annular rotor of the rotary microactuator by a DXRL process.
Optical Switch Using Risley Prisms
Sweatt, William C.; Christenson, Todd R.
2005-02-22
An optical switch using Risley prisms and rotary microactuators to independently rotate the wedge prisms of each Risley prism pair is disclosed. The optical switch comprises an array of input Risley prism pairs that selectively redirect light beams from a plurality of input ports to an array of output Risley prism pairs that similarly direct the light beams to a plurality of output ports. Each wedge prism of each Risley prism pair can be independently rotated by a variable-reluctance stepping rotary microactuator that is fabricated by a multi-layer LIGA process. Each wedge prism can be formed integral to the annular rotor of the rotary microactuator by a DXRL process.
Cerebellar inactivation impairs memory of learned prism gaze-reach calibrations.
Norris, Scott A; Hathaway, Emily N; Taylor, Jordan A; Thach, W Thomas
2011-05-01
Three monkeys performed a visually guided reach-touch task with and without laterally displacing prisms. The prisms offset the normally aligned gaze/reach and subsequent touch. Naive monkeys showed adaptation, such that on repeated prism trials the gaze-reach angle widened and touches hit nearer the target. On the first subsequent no-prism trial the monkeys exhibited an aftereffect, such that the widened gaze-reach angle persisted and touches missed the target in the direction opposite that of initial prism-induced error. After 20-30 days of training, monkeys showed long-term learning and storage of the prism gaze-reach calibration: they switched between prism and no-prism and touched the target on the first trials without adaptation or aftereffect. Injections of lidocaine into posterolateral cerebellar cortex or muscimol or lidocaine into dentate nucleus temporarily inactivated these structures. Immediately after injections into cortex or dentate, reaches were displaced in the direction of prism-displaced gaze, but no-prism reaches were relatively unimpaired. There was little or no adaptation on the day of injection. On days after injection, there was no adaptation and both prism and no-prism reaches were horizontally, and often vertically, displaced. A single permanent lesion (kainic acid) in the lateral dentate nucleus of one monkey immediately impaired only the learned prism gaze-reach calibration and in subsequent days disrupted both learning and performance. This effect persisted for the 18 days of observation, with little or no adaptation.
Cerebellar inactivation impairs memory of learned prism gaze-reach calibrations
Hathaway, Emily N.; Taylor, Jordan A.; Thach, W. Thomas
2011-01-01
Three monkeys performed a visually guided reach-touch task with and without laterally displacing prisms. The prisms offset the normally aligned gaze/reach and subsequent touch. Naive monkeys showed adaptation, such that on repeated prism trials the gaze-reach angle widened and touches hit nearer the target. On the first subsequent no-prism trial the monkeys exhibited an aftereffect, such that the widened gaze-reach angle persisted and touches missed the target in the direction opposite that of initial prism-induced error. After 20–30 days of training, monkeys showed long-term learning and storage of the prism gaze-reach calibration: they switched between prism and no-prism and touched the target on the first trials without adaptation or aftereffect. Injections of lidocaine into posterolateral cerebellar cortex or muscimol or lidocaine into dentate nucleus temporarily inactivated these structures. Immediately after injections into cortex or dentate, reaches were displaced in the direction of prism-displaced gaze, but no-prism reaches were relatively unimpaired. There was little or no adaptation on the day of injection. On days after injection, there was no adaptation and both prism and no-prism reaches were horizontally, and often vertically, displaced. A single permanent lesion (kainic acid) in the lateral dentate nucleus of one monkey immediately impaired only the learned prism gaze-reach calibration and in subsequent days disrupted both learning and performance. This effect persisted for the 18 days of observation, with little or no adaptation. PMID:21389311
Ring, Mariann; Harbauer, Gregor; Haas, Sebastian; Schuetz, Christopher; Andreae, Andreas; Maercker, Andreas; Ajdacic-Gross, Vladeta
2014-01-01
In routine clinical practice the assessment of suicidality proves to be difficult and complex. The aim of the present study was to examine if PRISM can be used to measure validly the person's subjectively perceived suicidality. The nonverbal visualization technique PRISM (Pictoral Representation of Illness and Self Measure) has been developed by Büchi et al. (2002) to evaluate the perceived burden of suffering due to physical illness. The adapted version of PRISM used in our study is called PRISM-S (Pictoral Representation of Illness and Self Measure - Suicidality). 156 eligible inpatients, admitted voluntarily to the crisis intervention centre Winterthur, participated in the study. We used as gold standards the well established assessment tools the Beck Scale of Suicide Ideation (BSS) and the Depressive Symptome Inventory - Subscale (DSI-SS). The results showed high correlations between PRISM-S and the BSS (r = - 0,73) and the DSI-SS scores (r = - 0,76). Clinicians, general practitioners, psychiatrists and psychologists receive with PRISM-S a valid suicidality assessment tool that is very brief and easy to administer in clinical settings.
The effect of compliant prisms on subduction zone earthquakes and tsunamis
NASA Astrophysics Data System (ADS)
Lotto, Gabriel C.; Dunham, Eric M.; Jeppson, Tamara N.; Tobin, Harold J.
2017-01-01
Earthquakes generate tsunamis by coseismically deforming the seafloor, and that deformation is largely controlled by the shallow rupture process. Therefore, in order to better understand how earthquakes generate tsunamis, one must consider the material structure and frictional properties of the shallowest part of the subduction zone, where ruptures often encounter compliant sedimentary prisms. Compliant prisms have been associated with enhanced shallow slip, seafloor deformation, and tsunami heights, particularly in the context of tsunami earthquakes. To rigorously quantify the role compliant prisms play in generating tsunamis, we perform a series of numerical simulations that directly couple dynamic rupture on a dipping thrust fault to the elastodynamic response of the Earth and the acoustic response of the ocean. Gravity is included in our simulations in the context of a linearized Eulerian description of the ocean, which allows us to model tsunami generation and propagation, including dispersion and related nonhydrostatic effects. Our simulations span a three-dimensional parameter space of prism size, prism compliance, and sub-prism friction - specifically, the rate-and-state parameter b - a that determines velocity-weakening or velocity-strengthening behavior. We find that compliant prisms generally slow rupture velocity and, for larger prisms, generate tsunamis more efficiently than subduction zones without prisms. In most but not all cases, larger, more compliant prisms cause greater amounts of shallow slip and larger tsunamis. Furthermore, shallow friction is also quite important in determining overall slip; increasing sub-prism b - a enhances slip everywhere along the fault. Counterintuitively, we find that in simulations with large prisms and velocity-strengthening friction at the base of the prism, increasing prism compliance reduces rather than enhances shallow slip and tsunami wave height.
Effects of Prism Eyeglasses on Objective and Subjective Fixation Disparity
Schroth, Volkhard; Joos, Roland; Jaschinski, Wolfgang
2015-01-01
In optometry of binocular vision, the question may arise whether prisms should be included in eyeglasses to compensate an oculomotor and/or sensory imbalance between the two eyes. The corresponding measures of objective and subjective fixation disparity may be reduced by the prisms, or the adaptability of the binocular vergence system may diminish effects of the prisms over time. This study investigates effects of wearing prisms constantly for about 5 weeks in daily life. Two groups of 12 participants received eyeglasses with prisms having either a base-in direction or a base-out direction with an amount up to 8 prism diopters. Prisms were prescribed based on clinical fixation disparity test plates at 6 m. Two dependent variables were used: (1) subjective fixation disparity was indicated by a perceived offset of dichoptic nonius lines that were superimposed on the fusion stimuli and (2) objective fixation disparity was measured with a video based eye tracker relative to monocular calibration. Stimuli were presented at 6 m and included either central or more peripheral fusion stimuli. Repeated measurements were made without the prisms and with the prisms after about 5 weeks of wearing these prisms. Objective and subjective fixation disparity were correlated, but the type of fusion stimulus and the direction of the required prism may play a role. The prisms did not reduce the fixation disparity to zero, but induced significant changes in fixation disparity with large effect sizes. Participants receiving base-out prisms showed hypothesized effects, which were concurrent in both types of fixation disparity. In participants receiving base-in prisms, the individual effects of subjective and objective effects were negatively correlated: the larger the subjective (sensory) effect, the smaller the objective (motor) effect. This response pattern was related to the vergence adaptability, i.e. the individual fusional vergence reserves. PMID:26431525
High-Power Prismatic Devices for Oblique Peripheral Prisms
Peli, Eli; Bowers, Alex R.; Keeney, Karen; Jung, Jae-Hyun
2016-01-01
ABSTRACT Purpose Horizontal peripheral prisms for hemianopia provide field expansion above and below the horizontal meridian; however, there is a vertical gap leaving the central area (important for driving) without expansion. In the oblique design, tilting the bases of both prism segments toward the horizontal meridian moves the field expansion area vertically and centrally (closing the central gap) while the prisms remain in the peripheral location. However, tilting the prisms results also in a reduction of the lateral field expansion. Higher prism powers are needed to counter this effect. Methods We developed, implemented, and tested a series of designs aimed at increasing the prism power to reduce the central gap while maintaining wide lateral expansion. The designs included inserting the peripheral prisms into carrier lenses that included yoked prism in the opposite direction, combination of two Fresnel segments attached at the base and angled to each other (bi-part prisms), and creating Fresnel prism–like segments from nonparallel periscopic mirror pairs (reflective prisms). Results A modest increase in lateral power was achieved with yoked-prism carriers. Bi-part combination of 36Δ Fresnel segments provided high power with some reduction in image quality. Fresnel reflective prism segments have potential for high power with superior optical quality but may be limited in field extent or by interruptions of the expanded field. Extended apical scotomas, even with unilateral fitting, may limit the utility of very high power prisms. The high-power bi-part and reflective prisms enable a wider effective eye scanning range (more than 15 degrees) into the blind hemifield. Conclusions Conventional prisms of powers higher than the available 57Δ are limited by the binocular impact of a wider apical scotoma and a reduced effective eye scanning range to the blind side. The various designs that we developed may overcome these limitations and find use in various other field expansion applications. PMID:26866438
Contamination of disposable tonometer prisms during tonometry.
Rajak, S N; Paul, J; Sharma, V; Vickers, S
2006-03-01
Due to the theoretical possibility of prion transmission in applanation tonometry, many ophthalmological units in the United Kingdom now use disposable tonometer prisms. We have investigated the potential for bacterial and viral transmission from the health practitioner to the patient via disposable prisms. All staff who perform applanation tonometry at the Sussex Eye Hospital (SEH) received a questionnaire to evaluate if the applanating face of the prism is touched during tonometry and the ease of use of the disposable prism compared to the reusable prisms that were previously used. We then cultured prisms handled by a random sample of staff members for common bacteria. Finally, we constructed a model to investigate the possibility of interpatient adenoviral transmission via disposable tonometer prisms. The questionnaire revealed that almost 50% of the staff admit to touching the applanating face of the tonometer prism prior to applanation. Cultures of the prisms grew a range of bacteria including Staphylococcus epidermidis, Staphylococcus aureus, and Bacillus species. The viral model suggested that adenovirus could be transmitted by applanation tonometry. The use of disposable prisms for applanation tonometry may reduce the risk of prion transmission but is not bacteriologically or virologically aseptic. This is a potential infection risk to patients.
Fresnel prisms and their effects on visual acuity and binocularity.
Véronneau-Troutman, S
1978-01-01
1. The visual acuity with the Fresnel membrane prism is significantly less than that with the conventional prism of the same power for all prism powers from 12 delta through 30 delata at distance and from 15 delta through 30 delta at near. 2. The difference in the visual acuity between base up and base down, and between base in and base out, is not significantly different for either the Fresnel membrane prism or for the conventional prism. 3. For both Fresnel membrane prism and the conventional prism, the visual acuity when looking straight ahead. 4. Using Fresnel membrane prisms of the same power from different lots, the visual acuity varied significantly. The 30 delta prism caused the widest range in visual acuity. 5. When normal subjects are fitted with the higher powers of the Fresnel membrane prism, fusion and stereopsis are disrupted to such an extent that the use of this device to restore or to improve binocular vision in cases with large-angle deviations is seriously questioned. 6. Moreover, the disruption of fusion and stereopsis is abrupt and severe and does not parallel the decrease in visual acuity. The severely reduced ability to maintain fusion may be related to the optical aberrations, which, in turn, may be due to the molding process and the polyvinyl chloride molding material. 7. Through the flexibility of the membrane prism is a definite advantage, because of its proclivity to reduce visual acuity and increase aberrations its prescription for adults often must be limited to only one eye. 8. For the same reasons in the young child with binocular vision problems, the membrane prism presently available should be prescribed over both eyes only in powers less than 20 delta. When the membrane prism is to be used as a partial occluder (over one eye only), any power can be used. 9. The new Fresnel "hard" prism reduces visual acuity minimally and rarely disrupts binocularity, thus increasing the potential for prismotherapy to establish binocularity. This prism is currently available only for use as a trial set. Since the cosmetic appearance of the Fresnel "hard" prism is similar to that of the Fresnel membrane prism and it is easier to maintain, it would be the prism of choice (over all other types) for bilateral prescriptions in the young patient with emmetropia. The manufacturer is urged to make these prisms available to fit a special round adjustable frame, such as that developed in Europe for use with the wafer prism. Images FIGURE 14 A FIGURE 14 B FIGURE 2 A FIGURE 2 B FIGURE 12 PMID:754384
Houston, Kevin E.; Peli, Eli; Goldstein, Robert B.; Bowers, Alex R.
2018-01-01
Purpose Drivers with homonymous hemianopia (HH) were previously found to have impaired detection of blind-side hazards, yet in many jurisdictions they may obtain a license. We evaluated whether oblique 57Δ peripheral prisms (p-prisms) and perceptual-motor training improved blind-side detection rates. Methods Patients with HH (n = 11) wore p-prisms for 2 weeks and then received perceptual-motor training (six visits) detecting and touching stimuli in the prism-expanded vision. In a driving simulator, patients drove and pressed the horn upon detection of pedestrians who ran toward the roadway (26 from each side): (1) without p-prisms at baseline; (2) with p-prisms after 2 weeks acclimation but before training; (3) with p-prisms after training; and (4) 3 months later. Results P-prisms improved blind-side detection from 42% to 56%, which further improved after training to 72% (all P < 0.001). Blind-side timely responses (adequate time to have stopped) improved from 31% without to 44% with p-prisms (P < 0.001) and further improved with training to 55% (P = 0.02). At the 3-month follow-up, improvements from training were maintained for detection (65%; P = 0.02) but not timely responses (P = 0.725). There was wide between-subject variability in baseline detection performance and response to p-prisms. There were no negative effects of p-prisms on vehicle control or seeing-side performance. Conclusions P-prisms improved detection with no negative effects, and training may provide additional benefit. Translational Relevance In jurisdictions where people with HH are legally driving, these data aid in clinical decision making by providing evidence that p-prisms improve performance without negative effects. PMID:29359111
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber...
Apfelbaum, Henry L.; Ross, Nicole C.; Bowers, Alex R.; Peli, Eli
2013-01-01
Purpose: While prisms are commonly prescribed for homonymous hemianopia to extend or expand the visual field, they cause potentially troubling visual side effects, including nonveridical location of perceived images, diplopia, and visual confusion. In addition, the field behind a prism at its apex is lost to an apical scotoma equal in magnitude to the amount of prism shift. The perceptual consequences of apical scotomas and the other effects of various designs were examined to consider parameters and designs that can mitigate the impact of these effects. Methods: Various configurations of sector and peripheral prisms were analyzed, in various directions of gaze, and their visual effects were illustrated using simulated perimetry. A novel “percept” diagram was developed that yielded insights into the patient's view through the prisms. The predictions were verified perimetrically with patients. Results: The diagrams distinguish between potentially beneficial field expansion via visual confusion and the pericentrally disturbing and useless effect of diplopia, and their relationship to prism power and gaze direction. They also illustrate the nonexpanding substitution of field segments of some popular prism designs. Conclusions: Yoked sector prisms have no effect at primary gaze or when gaze is directed toward the seeing hemifield, and they introduce pericentral field loss when gaze is shifted into them. When fitted unilaterally, sector prisms also have an effect only when the gaze is directed into the prism and may cause a pericentral scotoma and/or central diplopia. Peripheral prisms are effective at essentially all gaze angles. Since gaze is not directed into them, they avoid problematic pericentral effects. We derive useful recommendations for prism power and position parameters, including novel ways of fitting prisms asymmetrically. Translational Relevance: Clinicians will find these novel diagrams, diagramming techniques, and analyses valuable when prescribing prismatic aids for hemianopia and when designing new prism devices for patients with various types of field loss. PMID:24049719
Peripheral prism glasses: effects of moving and stationary backgrounds.
Shen, Jieming; Peli, Eli; Bowers, Alex R
2015-04-01
Unilateral peripheral prisms for homonymous hemianopia (HH) expand the visual field through peripheral binocular visual confusion, a stimulus for binocular rivalry that could lead to reduced predominance and partial suppression of the prism image, thereby limiting device functionality. Using natural-scene images and motion videos, we evaluated whether detection was reduced in binocular compared with monocular viewing. Detection rates of nine participants with HH or quadranopia and normal binocularity wearing peripheral prisms were determined for static checkerboard perimetry targets briefly presented in the prism expansion area and the seeing hemifield. Perimetry was conducted under monocular and binocular viewing with targets presented over videos of real-world driving scenes and still frame images derived from those videos. With unilateral prisms, detection rates in the prism expansion area were significantly lower in binocular than in monocular (prism eye) viewing on the motion background (medians, 13 and 58%, respectively, p = 0.008) but not the still frame background (medians, 63 and 68%, p = 0.123). When the stimulus for binocular rivalry was reduced by fitting prisms bilaterally in one HH and one normally sighted subject with simulated HH, prism-area detection rates on the motion background were not significantly different (p > 0.6) in binocular and monocular viewing. Conflicting binocular motion appears to be a stimulus for reduced predominance of the prism image in binocular viewing when using unilateral peripheral prisms. However, the effect was only found for relatively small targets. Further testing is needed to determine the extent to which this phenomenon might affect the functionality of unilateral peripheral prisms in more real-world situations.
Peripheral Prism Glasses: Effects of Moving and Stationary Backgrounds
Shen, Jieming; Peli, Eli; Bowers, Alex R.
2015-01-01
Purpose Unilateral peripheral prisms for homonymous hemianopia (HH) expand the visual field through peripheral binocular visual confusion, a stimulus for binocular rivalry that could lead to reduced predominance (partial local suppression) of the prism image and limit device functionality. Using natural-scene images and motion videos, we evaluated whether detection was reduced in binocular compared to monocular viewing. Methods Detection rates of nine participants with HH or quadranopia and normal binocularity wearing peripheral prisms were determined for static checkerboard perimetry targets briefly presented in the prism expansion area and the seeing hemifield. Perimetry was conducted under monocular and binocular viewing with targets presented over videos of real-world driving scenes and still frame images derived from those videos. Results With unilateral prisms, detection rates in the prism expansion area were significantly lower in binocular than monocular (prism eye) viewing on the motion background (medians 13% and 58%, respectively, p = 0.008), but not the still frame background (63% and 68%, p = 0.123). When the stimulus for binocular rivalry was reduced by fitting prisms bilaterally in 1 HH and 1 normally-sighted subject with simulated HH, prism-area detection rates on the motion background were not significantly different (p > 0.6) in binocular and monocular viewing. Conclusions Conflicting binocular motion appears to be a stimulus for reduced predominance of the prism image in binocular viewing when using unilateral peripheral prisms. However, the effect was only found for relatively small targets. Further testing is needed to determine the extent to which this phenomenon might affect the functionality of unilateral peripheral prisms in more real-world situations. PMID:25785533
Impact of high power and angle of incidence on prism corrections for visual field loss.
Jung, Jae-Hyun; Peli, Eli
2014-01-17
Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice.
[Research on improving spectrum resolution of optimized Wollaston prism array].
Zhang, Peng; Wang, Jian-Rong; Zhang, Guo-Chen; Hou, Wen
2011-11-01
In order to not affect the image quality of interference fringes on the basis of the structure by increasing the structure angle of Wollaston prism to improve spectrum resolution, the authors optimized the structure of Wollaston prism. Calculating the function of the splitting angle and the structure angle, analysis indicated that taking the isosceles triangle prism with the same nature of the second wedge-shaped prism after the Wollaston prism, which makes the o and e light parallel to the optical axis, and alpha=0 degrees, the imaging interference fringes are no longer affected by changes in the splitting angle. Several optimized Wollaston prisms were made as an array to improve the spectral resolution. Experiments used traditional and optimized Wollaston prism array to detect the spectrum of the 980 nm laser. Experimental data showed that using optimized Wollaston prism array gets a clearer contrast of interference fringes, and the spectral data with Fourier transform are more accurate with DSP.
Impact of high power and angle of incidence on prism corrections for visual field loss
Jung, Jae-Hyun; Peli, Eli
2014-01-01
Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice. PMID:24497649
Zhou, Jie; Du, Xuewen; Xu, Bing
2015-01-01
Formed by non-covalent interactions and not defined at genetic level, the assemblies of small molecules in biology are complicated and less explored. A common morphology of the supramolecular assemblies of small molecules is nanofibrils, which coincidentally resembles the nanofibrils formed by proteins such as prions. So these supramolecular assemblies are termed as prion-like nanofibrils of small molecules (PriSM). Emerging evidence from several unrelated fields over the past decade implies the significance of PriSM in biology and medicine. This perspective aims to highlight some recent advances of the research on PriSM. This paper starts with description of the intriguing similarities between PriSM and prions, discusses the paradoxical features of PriSM, introduces the methods for elucidating the biological functions of PriSM, illustrates several examples of beneficial aspects of PriSM, and finishes with the promises and current challenges in the research of PriSM. We anticipate that the research of PriSM will contribute to the fundamental understanding at the intersection of supramolecular chemistry and cell biology and ultimately lead to a new paradigm of molecular (or supramolecular) therapeutics for biomedicine.
Zhou, Jie; Du, Xuewen; Xu, Bing
2015-01-01
Abstract Formed by non-covalent interactions and not defined at genetic level, the assemblies of small molecules in biology are complicated and less explored. A common morphology of the supramolecular assemblies of small molecules is nanofibrils, which coincidentally resembles the nanofibrils formed by proteins such as prions. So these supramolecular assemblies are termed as prion-like nanofibrils of small molecules (PriSM). Emerging evidence from several unrelated fields over the past decade implies the significance of PriSM in biology and medicine. This perspective aims to highlight some recent advances of the research on PriSM. This paper starts with description of the intriguing similarities between PriSM and prions, discusses the paradoxical features of PriSM, introduces the methods for elucidating the biological functions of PriSM, illustrates several examples of beneficial aspects of PriSM, and finishes with the promises and current challenges in the research of PriSM. We anticipate that the research of PriSM will contribute to the fundamental understanding at the intersection of supramolecular chemistry and cell biology and ultimately lead to a new paradigm of molecular (or supramolecular) therapeutics for biomedicine. PMID:25738892
Prism adaptation speeds reach initiation in the direction of the prism after-effect.
Striemer, Christopher L; Borza, Carley A
2017-10-01
Damage to the temporal-parietal cortex in the right hemisphere often leads to spatial neglect-a disorder in which patients are unable to attend to sensory input from their contralesional (left) side. Neglect has been associated with both attentional and premotor deficits. That is, in addition to having difficulty with attending to the left side, patients are often slower to initiate leftward vs. rightward movements (i.e., directional hypokinesia). Previous research has indicated that a brief period of adaptation to rightward shifting prisms can reduce symptoms of neglect by adjusting the patient's movements leftward, toward the neglected field. Although prism adaptation has been shown to reduce spatial attention deficits in patients with neglect, very little work has examined the effects of prisms on premotor symptoms. In the current study, we examined this in healthy individuals using leftward shifting prisms to induce a rightward shift in the egocentric reference frame, similar to neglect patients prior to prism adaptation. Specifically, we examined the speed with which healthy participants initiated leftward and rightward reaches (without visual feedback) prior to and following adaptation to either 17° leftward (n = 16) or 17° rightward (n = 15) shifting prisms. Our results indicated that, following adaptation, participants were significantly faster to initiate reaches towards targets located in the direction opposite the prism shift. That is, participants were faster to initiate reaches to right targets following leftward prism adaptation and were faster to initiate reaches to left targets following rightward prism adaptation. Overall, these results are consistent with the idea that prism adaptation can influence the speed with which a reach can be initiated toward a target in the direction opposite the prism shift, possibly through altering activity in neural circuits involved in reach planning.
Mühleisen, Beda; Büchi, Stefan; Schmidhauser, Simone; Jenewein, Josef; French, Lars E; Hofbauer, Günther F L
2009-07-01
To validate the PRISM (Pictorial Representation of Illness and Self Measure) tool, a novel visual instrument, for the assessment of health-related quality of life in dermatological inpatients compared with the Dermatology Life Quality Index (DLQI) and the Skindex-29 questionnaires and to report qualitative information on PRISM. In an open longitudinal study, PRISM and Skindex-29 and DLQI questionnaires were completed and HRQOL measurements compared. Academic dermatological inpatient ward. The study population comprised 227 sequential dermatological inpatients on admission. Patients completed the PRISM tool and the Skindex-29 and DLQI questionnaires at admission and discharge. PRISM Self-Illness Separation (SIS) score; Skindex-29 and DLQI scores; and qualitative PRISM information by Mayring inductive qualitative context analysis. The PRISM scores correlated well with those from the Skindex-29 (rho = 0.426; P < .001) and DLQI (rho = 0.304; P < .001) questionnaires. Between PRISM and Skindex-29 scores, the highest correlations were for dermatitis (rho = 0.614) and leg ulcer (rho = 0.554), and between PRISM and DLQI scores, the highest correlations were for psoriasis (rho = 0.418) and tumor (rho = 0.399). The PRISM tool showed comparable or higher sensitivity than quality of life questionnaires to assess changes in the burden of suffering during hospitalization. Inductive qualitative context analysis revealed impairment of adjustment and self-image as major aspects. Patients overall expected symptomatic and functional improvement. In patients with psoriasis and leg ulcers, many expected no treatment benefit. The PRISM tool proved to be convenient and reliable for health-related quality of life assessment, applicable for a wide range of skin diseases, and correlated with DLQI and Skindex-29 scores. With the PRISM tool, free-text answers allow for the assessment of individual information and potentially customized therapeutic approaches.
Asymmetric transmission in prisms using structures and materials with isotropic-type dispersion.
Gundogdu, Funda Tamara; Serebryannikov, Andriy E; Cakmak, A Ozgur; Ozbay, Ekmel
2015-09-21
It is demonstrated that strong asymmetry in transmission can be obtained at the Gaussian beam illumination for a single prism based on a photonic crystal (PhC) with isotropic-type dispersion, as well as for its analog made of a homogeneous material. Asymmetric transmission can be realized with the aid of refraction at a proper orientation of the interfaces and wedges of the prism, whereas neither contribution of higher diffraction orders nor anisotropic-type dispersion is required. Furthermore, incidence toward a prism wedge can be used for one of two opposite directions in order to obtain asymmetry. Thus, asymmetric transmission is a general property of the prism configurations, which can be obtained by using simple geometries and quite conventional materials. The obtained results show that strong asymmetry can be achieved in PhC prisms with (nearly) circular shape of equifrequency dispersion contours, in both cases associated with the index of refraction 0
Stereoacuity as an indicator of prism adaptation.
Momeni-Moghaddam, Hamed; Eperjesi, Frank; Kundart, James; Mostafavi-Nam, Kazem
2014-08-01
The purpose of this study was to determine whether stereoacuity can be used as an indicator of prism adaptation. In particular, we wanted to know whether the time required for stereoacuity to return to the initial level after viewing through a prism can be used to determine the degree of adaptation. Eighteen subjects participated in this study. Stereoacuity and dissociated phoria were determined using the TNO stereotest and the Maddox rod, respectively. Prism vergences were measured using a prism bar. For each participant, prism power equivalent to the blur point of base-in (BI) and base-out (BO) fusional vergence at 40 cm was divided and placed in front of both eyes. At 0, 3, 6, 9 and 12 min after prism introduction, the stereoacuity was measured, and at 0 and 12 min, the heterophoria was measured. The repeated measures ANOVA showed a significant difference between the mean stereoacuity for BI and BO prisms at the different measurement times (p < 0.05). For BO prism, the initial value was different between 0 and 3 min after the prism introduction, whereas for BI prism, a difference in stereoacuity was found between the pre-prism value and the value at 0, 3 and 6 min. The size of the heterophoria with BO and BI prisms was different from 0 to 12 min (p < 0.05). The time required for stereoacuity to return to baseline level was more than 3 min for BO, and more than 6 min for BI prism. In addition, the time required to return to baseline values was not similar for the stereoacuity and heterophoria. The recovery of stereoacuity is slower when adapting to divergence, as when looking from near to far. This implies that stereopsis responds faster to near targets than to distant one, and may precede complete phoria adaptation.
First-order approximation error analysis of Risley-prism-based beam directing system.
Zhao, Yanyan; Yuan, Yan
2014-12-01
To improve the performance of a Risley-prism system for optical detection and measuring applications, it is necessary to be able to determine the direction of the outgoing beam with high accuracy. In previous works, error sources and their impact on the performance of the Risley-prism system have been analyzed, but their numerical approximation accuracy was not high. Besides, pointing error analysis of the Risley-prism system has provided results for the case when the component errors, prism orientation errors, and assembly errors are certain. In this work, the prototype of a Risley-prism system was designed. The first-order approximations of the error analysis were derived and compared with the exact results. The directing errors of a Risley-prism system associated with wedge-angle errors, prism mounting errors, and bearing assembly errors were analyzed based on the exact formula and the first-order approximation. The comparisons indicated that our first-order approximation is accurate. In addition, the combined errors produced by the wedge-angle errors and mounting errors of the two prisms together were derived and in both cases were proved to be the sum of errors caused by the first and the second prism separately. Based on these results, the system error of our prototype was estimated. The derived formulas can be implemented to evaluate beam directing errors of any Risley-prism beam directing system with a similar configuration.
Forward and inverse solutions for three-element Risley prism beam scanners.
Li, Anhu; Liu, Xingsheng; Sun, Wansong
2017-04-03
Scan blind zone and control singularity are two adverse issues for the beam scanning performance in double-prism Risley systems. In this paper, a theoretical model which introduces a third prism is developed. The critical condition for a fully eliminated scan blind zone is determined through a geometric derivation, providing several useful formulae for three-Risley-prism system design. Moreover, inverse solutions for a three-prism system are established, based on the damped least-squares iterative refinement by a forward ray tracing method. It is shown that the efficiency of this iterative calculation of the inverse solutions can be greatly enhanced by a numerical differentiation method. In order to overcome the control singularity problem, the motion law of any one prism in a three-prism system needs to be conditioned, resulting in continuous and steady motion profiles for the other two prisms.
Dynamic changes in brain activity during prism adaptation.
Luauté, Jacques; Schwartz, Sophie; Rossetti, Yves; Spiridon, Mona; Rode, Gilles; Boisson, Dominique; Vuilleumier, Patrik
2009-01-07
Prism adaptation does not only induce short-term sensorimotor plasticity, but also longer-term reorganization in the neural representation of space. We used event-related fMRI to study dynamic changes in brain activity during both early and prolonged exposure to visual prisms. Participants performed a pointing task before, during, and after prism exposure. Measures of trial-by-trial pointing errors and corrections allowed parametric analyses of brain activity as a function of performance. We show that during the earliest phase of prism exposure, anterior intraparietal sulcus was primarily implicated in error detection, whereas parieto-occipital sulcus was implicated in error correction. Cerebellum activity showed progressive increases during prism exposure, in accordance with a key role for spatial realignment. This time course further suggests that the cerebellum might promote neural changes in superior temporal cortex, which was selectively activated during the later phase of prism exposure and could mediate the effects of prism adaptation on cognitive spatial representations.
A Pilot Study of Perceptual-Motor Training for Peripheral Prisms
Houston, Kevin E.; Bowers, Alex R.; Fu, Xianping; Liu, Rui; Goldstein, Robert B.; Churchill, Jeff; Wiegand, Jean-Paul; Soo, Tim; Tang, Qu; Peli, Eli
2016-01-01
Purpose Peripheral prisms (p-prisms) shift peripheral portions of the visual field of one eye, providing visual field expansion for patients with hemianopia. However, patients rarely show adaption to the shift, incorrectly localizing objects viewed within the p-prisms. A pilot evaluation of a novel computerized perceptual-motor training program aiming to promote p-prism adaption was conducted. Methods Thirteen patients with hemianopia fitted with 57Δ oblique p-prisms completed the training protocol. They attended six 1-hour visits reaching and touching peripheral checkerboard stimuli presented over videos of driving scenes while fixating a central target. Performance was measured at each visit and after 3 months. Results There was a significant reduction in touch error (P = 0.01) for p-prism zone stimuli from pretraining median of 16.6° (IQR 12.1°–19.6°) to 2.7° ( IQR 1.0°–8.5°) at the end of training. P-prism zone reaction times did not change significantly with training (P > 0.05). P-prism zone detection improved significantly (P = 0.01) from a pretraining median 70% (IQR 50%–88%) to 95% at the end of training (IQR 73%–98%). Three months after training improvements had regressed but performance was still better than pretraining. Conclusions Improved pointing accuracy for stimuli detected in prism-expanded vision of patients with hemianopia wearing 57Δ oblique p-prisms is possible and training appears to further improve detection. Translational Relevance This is the first use of this novel software to train adaptation of visual direction in patients with hemianopia wearing peripheral prisms. PMID:26933522
Single-lens stereovision system using a prism: position estimation of a multi-ocular prism.
Cui, Xiaoyu; Lim, Kah Bin; Zhao, Yue; Kee, Wei Loon
2014-05-01
In this paper, a position estimation method using a prism-based single-lens stereovision system is proposed. A multifaced prism was considered as a single optical system composed of few refractive planes. A transformation matrix which relates the coordinates of an object point to its coordinates on the image plane through the refraction of the prism was derived based on geometrical optics. A mathematical model which is able to denote the position of an arbitrary faces prism with only seven parameters is introduced. This model further extends the application of the single-lens stereovision system using a prism to other areas. Experimentation results are presented to prove the effectiveness and robustness of our proposed model.
NASA Technical Reports Server (NTRS)
Ammann, E. O.; Massey, G. A.
1970-01-01
Inexpensive Rochon prisms can be produced by substituting easily polished glass for one-half of the calcite. Reciprocal polarizing properties of a conventional Rochon prism are retained, and angular separation between ordinary and extraordinary rays is the same as in all-calcite prism.
Goldmann tonometer error correcting prism: clinical evaluation.
McCafferty, Sean; Lim, Garrett; Duncan, William; Enikov, Eniko T; Schwiegerling, Jim; Levine, Jason; Kew, Corin
2017-01-01
Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness, stiffness, curvature, and tear film adhesion force. A comparative clinical study of 109 eyes measured IOP with CATS and Goldmann prisms. The IOP measurement differences between the CATS and Goldmann prisms were correlated to corneal thickness, hysteresis, and curvature. The CATS tonometer prism in correcting for Goldmann central corneal thickness (CCT) error demonstrated a reduction to <±2 mmHg in 97% of a standard CCT population. This compares to only 54% with CCT error <±2 mmHg using the Goldmann prism. Equal reductions of ~50% in errors due to corneal rigidity and curvature were also demonstrated. The results validate the CATS prism's improved accuracy and expected reduced sensitivity to Goldmann errors without IOP bias as predicted by mathematical modeling. The CATS replacement for the Goldmann prism does not change Goldmann measurement technique or interpretation.
Studying the neural bases of prism adaptation using fMRI: A technical and design challenge.
Bultitude, Janet H; Farnè, Alessandro; Salemme, Romeo; Ibarrola, Danielle; Urquizar, Christian; O'Shea, Jacinta; Luauté, Jacques
2017-12-01
Prism adaptation induces rapid recalibration of visuomotor coordination. The neural mechanisms of prism adaptation have come under scrutiny since the observations that the technique can alleviate hemispatial neglect following stroke, and can alter spatial cognition in healthy controls. Relative to non-imaging behavioral studies, fMRI investigations of prism adaptation face several challenges arising from the confined physical environment of the scanner and the supine position of the participants. Any researcher who wishes to administer prism adaptation in an fMRI environment must adjust their procedures enough to enable the experiment to be performed, but not so much that the behavioral task departs too much from true prism adaptation. Furthermore, the specific temporal dynamics of behavioral components of prism adaptation present additional challenges for measuring their neural correlates. We developed a system for measuring the key features of prism adaptation behavior within an fMRI environment. To validate our configuration, we present behavioral (pointing) and head movement data from 11 right-hemisphere lesioned patients and 17 older controls who underwent sham and real prism adaptation in an MRI scanner. Most participants could adapt to prismatic displacement with minimal head movements, and the procedure was well tolerated. We propose recommendations for fMRI studies of prism adaptation based on the design-specific constraints and our results.
Disposable versus non-disposable tonometer prisms: a UK national survey
Jasani, Kirti M; Putri, Christine; Pearl, Amy; Sattar, Nayeem; Mercieca, Karl; Spaeth, George; Bhan-Bhargava, Archana
2017-01-01
Purpose To determine the prevalence of disposable tonometer versus non-disposable tonometer use in the UK and to determine methods of decontamination and frequency of replacement of prisms. A total of 137 ophthalmology departments were interviewed by telephone using a structured questionnaire. The main outcome measured were:types of tonometer prisms used in clinic (disposable, non-disposable and/or other)average disposable prisms used per clinic sessionaverage lifespan of non-disposable prismsprism preference by glaucoma and other teams within department. A cost and benefit analysis was then performed on the data acquired. Results One hundred and fifty-five departments were identified for the survey. Of these, 137 (88.3%) responded. Eighty-one departments (59.1%) used Tonosafe prisms alone, whereas 22 departments (16.1%) used Goldmann non-disposable prisms exclusively. Thirty-five departments (64%) on average have a change rate of 26.5% per year (range: 0–100, median: 20) attributed to damage, loss or theft. Sixteen departments (29%) reported that prisms were used until damaged or lost. Four departments (7%) were uncertain of their prism usage and could not provide further information. Conclusions Majority of eye departments in the UK opt for disposable prisms. This survey shows the perceived cost-effectiveness of disposable prisms is overestimated when the true cost of disinfection and damage is taken into account. Significant cost savings coupled with the low risk of infectivity (if decontaminated properly) should prompt clinicians and ophthalmic departments worldwide to reconsider the use of non-disposable prisms. PMID:29354698
Resultant vertical prism in toric soft contact lenses.
Sulley, Anna; Hawke, Ryan; Lorenz, Kathrine Osborn; Toubouti, Youssef; Olivares, Giovanna
2015-08-01
Rotational stability of toric soft contact lenses (TSCLs) is achieved using a range of designs. Designs utilising prism or peripheral ballast may result in residual prism in the optic zone. This study quantifies the vertical prism in the central 6mm present in TSCLs with various stabilisation methods. Vertical prism was computed using published refractive index and vertical thickness changes in the central optic zone on a full lens thickness map. Thickness maps were measured using scanning transmission microscopy. Designs tested were reusable, silicone hydrogel and hydrogel TSCLs: SofLens(®) Toric, PureVision(®)2 for Astigmatism, PureVision(®) Toric, Biofinity(®) Toric, Avaira(®) Toric, clariti(®) toric, AIR OPTIX(®) for ASTIGMATISM and ACUVUE OASYS(®) for ASTIGMATISM; with eight parameter combinations for each lens (-6.00DS to +3.00DS, -1.25DC, 90° and 180° axes). All TSCL designs evaluated had vertical prism in the optic zone except one which had virtually none (0.01Δ). Mean prism ranged from 0.52Δ to 1.15Δ, with three designs having prism that varied with sphere power. Vertical prism in ACUVUE OASYS(®) for ASTIGMATISM was significantly lower than all other TSCLs tested. TSCL designs utilising prism-ballast and peri-ballast for stabilisation have vertical prism in the central optic zone. In monocular astigmats fitted with a TSCL or those wearing a mix of toric designs, vertical prism imbalance could create or exacerbate disturbances in binocular vision function. Practitioners should be aware of this potential effect when selecting which TSCL designs to prescribe, particularly for monocular astigmats with pre-existing binocular vision anomalies, and when managing complaints of asthenopia in monocular astigmats. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Prism adaptation magnitude has differential influences on perceptual versus manual responses.
Striemer, Christopher L; Russell, Karyn; Nath, Priya
2016-10-01
Previous research has indicated that rightward prism adaptation can reduce symptoms of spatial neglect following right brain damage. In addition, leftward prism adaptation can create "neglect-like" patterns of performance in healthy adults on tasks that measure attention and spatial biases. Although a great deal of research has focused on which behaviors are influenced by prism adaptation, very few studies have focused directly on how the magnitude of visual shift induced by prisms might be related to the observed aftereffects, or the effects of prisms on measures of attentional and spatial biases. In the current study, we examined these questions by having groups of healthy adult participants complete manual line bisection and landmark tasks prior to and following adaptation to either 8.5° (15 diopter; n = 22) or 17° (30 diopter; n = 25) leftward shifting prisms. Our results demonstrated a significantly larger rightward shift in straight-ahead pointing (a measure of prism aftereffect) following adaptation to 17°, compared to 8.5° leftward shifting prisms. In addition, only 17° leftward shifting prisms resulted in a significant rightward shift in line bisection following adaptation. However, there was a significant change in performance on the landmark task pre- versus post-adaptation in both the 8.5° and 17° leftward shifting prism groups. Interestingly, correlation analyses indicated that changes in straight-ahead pointing pre- versus post-adaptation were positively correlated with changes in performance on the manual line bisection task, but not the landmark task. These data suggest that larger magnitudes of prism adaptation seem to have a greater influence on tasks that require a response with the adapted hand (i.e., line bisection), compared to tasks that only require a perceptual judgment (i.e., the landmark task). In addition, these data provide further evidence that the effects of prisms on manual and perceptual responses are not related to one another.
Rotatable prism for pan and tilt
NASA Technical Reports Server (NTRS)
Ball, W. B.
1980-01-01
Compact, inexpensive, motor-driven prisms change field of view of TV camera. Camera and prism rotate about lens axis to produce pan effect. Rotating prism around axis parallel to lens produces tilt. Size of drive unit and required clearance are little more than size of camera.
21 CFR 886.1660 - Gonioscopic prism.
Code of Federal Regulations, 2010 CFR
2010-04-01
... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber. The device may have angled mirrors to facilitate visualization of anatomical features. (b...
Kuang, Yi; Long, Marcus J. C.; Zhou, Jie; Shi, Junfeng; Gao, Yuan; Xu, Chen; Hedstrom, Lizbeth; Xu, Bing
2014-01-01
Emerging evidence reveals that prion-like structures play important roles to maintain the well-being of cells. Although self-assembly of small molecules also affords prion-like nanofibrils (PriSM), little is known about the functions and mechanisms of PriSM. Previous works demonstrated that PriSM formed by a dipeptide derivative selectively inhibiting the growth of glioblastoma cells over neuronal cells and effectively inhibiting xenograft tumor in animal models. Here we examine the protein targets, the internalization, and the cytotoxicity pathway of the PriSM. The results show that the PriSM selectively accumulate in cancer cells via macropinocytosis to impede the dynamics of cytoskeletal filaments via promiscuous interactions with cytoskeletal proteins, thus inducing apoptosis. Intriguingly, Tau proteins are able to alleviate the effect of the PriSM, thus protecting neuronal cells. This work illustrates PriSM as a new paradigm for developing polypharmacological agents that promiscuously interact with multiple proteins yet result in a primary phenotype, such as cancer inhibition PMID:25157102
Pure rotation of a prism on a ramp
Zhao, Zhen; Liu, Caishan; Ma, Daolin
2014-01-01
In this work, we study a prism with a cross section in polygon rolling on a ramp inclined at a small angle. The prism under gravity rolls purely around each individual edge, intermittently interrupted by a sequence of face collisions between the side face of the prism and the ramp. By limiting the prism in a planar motion, we propose a mathematical model to deal with the events of the impacts. With a pair of laser-Doppler vibrometers, experiments are also conducted to measure the motions of various prisms made of different materials and with different edge number. Not only are good agreements achieved between our numerical and experimental results, but also an intriguing physical phenomenon is discovered: the purely rolling motion is nearly independent of the prism's materials, yet it is closely related to the prism's geometry. Imagine that an ideal circular section can be approximately equivalent to a polygon with a large enough edge number N, the finding presented in this paper may help discover the physical mechanism of rolling friction. PMID:25197242
Compound prism design principles, I
Hagen, Nathan; Tkaczyk, Tomasz S.
2011-01-01
Prisms have been needlessly neglected as components used in modern optical design. In optical throughput, stray light, flexibility, and in their ability to be used in direct-view geometry, they excel over gratings. Here we show that even their well-known weak dispersion relative to gratings has been overrated by designing doublet and double Amici direct-vision compound prisms that have 14° and 23° of dispersion across the visible spectrum, equivalent to 800 and 1300 lines/mm gratings. By taking advantage of the multiple degrees of freedom available in a compound prism design, we also show prisms whose angular dispersion shows improved linearity in wavelength. In order to achieve these designs, we exploit the well-behaved nature of prism design space to write customized algorithms that optimize directly in the nonlinear design space. Using these algorithms, we showcase a number of prism designs that illustrate a performance and flexibility that goes beyond what has often been considered possible with prisms. PMID:22423145
Tuncbag, Nurcan; Gursoy, Attila; Nussinov, Ruth; Keskin, Ozlem
2011-08-11
Prediction of protein-protein interactions at the structural level on the proteome scale is important because it allows prediction of protein function, helps drug discovery and takes steps toward genome-wide structural systems biology. We provide a protocol (termed PRISM, protein interactions by structural matching) for large-scale prediction of protein-protein interactions and assembly of protein complex structures. The method consists of two components: rigid-body structural comparisons of target proteins to known template protein-protein interfaces and flexible refinement using a docking energy function. The PRISM rationale follows our observation that globally different protein structures can interact via similar architectural motifs. PRISM predicts binding residues by using structural similarity and evolutionary conservation of putative binding residue 'hot spots'. Ultimately, PRISM could help to construct cellular pathways and functional, proteome-scale annotation. PRISM is implemented in Python and runs in a UNIX environment. The program accepts Protein Data Bank-formatted protein structures and is available at http://prism.ccbb.ku.edu.tr/prism_protocol/.
Pure rotation of a prism on a ramp.
Zhao, Zhen; Liu, Caishan; Ma, Daolin
2014-09-08
In this work, we study a prism with a cross section in polygon rolling on a ramp inclined at a small angle. The prism under gravity rolls purely around each individual edge, intermittently interrupted by a sequence of face collisions between the side face of the prism and the ramp. By limiting the prism in a planar motion, we propose a mathematical model to deal with the events of the impacts. With a pair of laser-Doppler vibrometers, experiments are also conducted to measure the motions of various prisms made of different materials and with different edge number. Not only are good agreements achieved between our numerical and experimental results, but also an intriguing physical phenomenon is discovered: the purely rolling motion is nearly independent of the prism's materials, yet it is closely related to the prism's geometry. Imagine that an ideal circular section can be approximately equivalent to a polygon with a large enough edge number N , the finding presented in this paper may help discover the physical mechanism of rolling friction.
Mechanism of Prism-Coupled Scanning Tunneling Microscope Light Emission
NASA Astrophysics Data System (ADS)
Iida, Wataru; Ahamed, Jamal U.; Katano, Satoshi; Uehara, Yoichi
2011-09-01
We have investigated the mechanism of scanning tunneling microscope light emission (STM-LE) in a prism-coupled configuration using finite difference time domain analysis. In this configuration, the sample is a metallic thin film evaporated on the bottom surface of a hemispherical glass prism. STM light emitted into the prism (prism-side emission) through the metallic film is measured. Since both localized surface plasmons (LSP) and surface plasmon polaritons (SPP) contribute to prism-side emission, this emission is stronger than that in conventional STM-LE measured from the sample surface side, which is radiated by LSP alone. We show that the spatial resolution of prism-side emission is determined not by the propagation length of SPP, but by the lateral size of LSP, similarly to conventional (i.e., tip side) STM-LE. Thus, we conclude that, by using the prism-coupled configuration, the signal level of STM-LE improves without the loss of spatial resolution attained in tip side emission.
NASA Astrophysics Data System (ADS)
Idris, N.; Maswati; Yusibani, E.
2018-05-01
The influence of the apex angle of a hollow prism used as a simple refractometer to the accuracy of a refractive index measurement of the edible oil samples was studied. The hollow prism was made from an ordinary commercial glass plate with a thickness of 2 mm. The apex angle of the constructed hollow prism was varied. The edible oil sample used in this study was palm oil, namely the packaged, branded oil sample and the bulk oil sample. For measuring the refractive index, the oil sample was filled in the constructed hollow prism, and then a helium-neon laser beam was passed through the oil sample at a certain angle of incidence. The angle of minimum deviation of the transmitted laser He-Ne beam was measured and then was used for calculating the refractive index of the oil sample. The refractive index measurement was made using the hollow prism with different apex angles, ranging from 300 to 600. The measurement accuracy was estimated by comparing the refractive index measured using the hollow prisms to that of obtained using a standard Abbe refractometer. It was found that the refractive index of the edible oil can be measured accurately by using the hollow prism. It was also found that the accuracy of the refractive index measurement significantly changes with the apex angle of the hollow prism. The refractive index values measured using this simple refractometer deviate up to 3,49% from the refractive index value measured using the standard Abbe refractometer, especially when the apex angle of the prism is 30°. The measurement results with high accuracies obtained when using the hollow prisms with apex angles of 450 and 600. The optimum apex angle for the present constructed hollow prism is 450. The refractive index obtained using the hollow prism with the apex angle of 450 is 1,4623 and 1,4438 for the bulk oil and the packed, branded oil samples, respectively. This result suggests that the apex angle of the prism used affects largely the accuracy of the refractive index measurement.
An improved prism for use in laser resonators
NASA Astrophysics Data System (ADS)
Richards, J.
1981-08-01
The use of compound total internal reflection prisms rather than Porro prisms in polarisation coupled lasers is proposed. Performance advantages resulting from the use of these prisms include higher output without the need to bias the Pockels cell, ability to give a larger range of output coupling and independence of performance on the refractive index of the prism. In conventional Q-switched lasers the use of the prism at the Pockels cell end of the resonator instead of the usual 100% reflecting mirror also leads to some advantages including better hold-off, elimination of the need to bias the Pockels cell and insensitivity in one plane to angular misalignment.
An Improved Prism for Use in Laser Resonators
1981-08-01
reflection (TIR) prisms , will be shown to give significant advantages over the use of Porro prisms when used in polarisation coupled laser resonators . 2... resonator as shown in figure 2. As in the case of the crossed- Porro laser an in-line or folded configuration can be used. The compound TIR prism at the...thrashold, etc, rather than on refractive index, as in the case of Porro prisms . In conventional Q-switched Nd:YAG resonators , replacement of the 100
The Geometric Theory of Roof Reflector Resonators
1976-12-01
reflector, if properly oriented, (The terms "roof-top prism ," "right-angle prism ," and - incorrectly - " Porro prism " are encountered in .the literature...Q-switch prisms ) in laser resonators have been infrequent compared to the attention given spherical mirrors. This chapter summarizes the relevant...designator (Refs 42 and 43). In one experiment, a 900 roof prism was tested in a resonator with a 70% reflecting filat mirror. Thus, in Fig. 2, the right roof
Successful treatment of diplopia with prism improves health-related quality of life.
Hatt, Sarah R; Leske, David A; Liebermann, Laura; Holmes, Jonathan M
2014-06-01
To report change in strabismus-specific health-related quality of life (HRQOL) following treatment with prism. Retrospective cross-sectional study. Thirty-four patients with diplopia (median age 63, range 14-84 years) completed the Adult Strabismus-20 questionnaire (100-0, best to worst HRQOL) and a diplopia questionnaire in a clinical practice before prism and in prism correction. Before prism, diplopia was "sometimes" or worse for reading and/or straight-ahead distance. Prism treatment success was defined as diplopia rated "never" or "rarely" on the diplopia questionnaire for reading and straight-ahead distance. Failure was defined as worsening or no change in diplopia. For both successes and failures, mean Adult Strabismus-20 scores were compared before prism and in prism correction. Each of the 4 Adult Strabismus-20 domains (self-perception, interactions, reading function, and general function) was analyzed separately. Twenty-three of 34 (68%) were successes and 11 (32%) were failures. For successes, reading function improved from 57 ± 27 (SD) before prism to 69 ± 27 in-prism correction (difference 12 ± 20, 95% CI 3.2-20.8, P = .02) and general function improved from 66 ± 25 to 80 ± 18 (difference 14 ± 22, 95% CI 5.0-23.6, P = .003). Self-perception and interaction domains remained unchanged (P > .2). For failures there was no significant change in Adult Strabismus-20 score on any domain (P > .4). Successful correction of diplopia with prism is associated with improvement in strabismus-specific HRQOL, specifically reading function and general function. Copyright © 2014 Elsevier Inc. All rights reserved.
Epidemiology, genetics, and subtyping of preserved ratio impaired spirometry (PRISm) in COPDGene.
Wan, Emily S; Castaldi, Peter J; Cho, Michael H; Hokanson, John E; Regan, Elizabeth A; Make, Barry J; Beaty, Terri H; Han, MeiLan K; Curtis, Jeffrey L; Curran-Everett, Douglas; Lynch, David A; DeMeo, Dawn L; Crapo, James D; Silverman, Edwin K
2014-08-06
Preserved Ratio Impaired Spirometry (PRISm), defined as a reduced FEV1 in the setting of a preserved FEV1/FVC ratio, is highly prevalent and is associated with increased respiratory symptoms, systemic inflammation, and mortality. Studies investigating quantitative chest tomographic features, genetic associations, and subtypes in PRISm subjects have not been reported. Data from current and former smokers enrolled in COPDGene (n = 10,192), an observational, cross-sectional study which recruited subjects aged 45-80 with ≥10 pack years of smoking, were analyzed. To identify epidemiological and radiographic predictors of PRISm, we performed univariate and multivariate analyses comparing PRISm subjects both to control subjects with normal spirometry and to subjects with COPD. To investigate common genetic predictors of PRISm, we performed a genome-wide association study (GWAS). To explore potential subgroups within PRISm, we performed unsupervised k-means clustering. The prevalence of PRISm in COPDGene is 12.3%. Increased dyspnea, reduced 6-minute walk distance, increased percent emphysema and decreased total lung capacity, as well as increased segmental bronchial wall area percentage were significant predictors (p-value <0.05) of PRISm status when compared to control subjects in multivariate models. Although no common genetic variants were identified on GWAS testing, a significant association with Klinefelter's syndrome (47XXY) was observed (p-value < 0.001). Subgroups identified through k-means clustering include a putative "COPD-subtype", "Restrictive-subtype", and a highly symptomatic "Metabolic-subtype". PRISm subjects are clinically and genetically heterogeneous. Future investigations into the pathophysiological mechanisms behind and potential treatment options for subgroups within PRISm are warranted. Clinicaltrials.gov Identifier: NCT000608764.
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
21 CFR 886.1655 - Ophthalmic Fresnel prism.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings which...
Ultradispersive adaptive prism based on a coherently prepared atomic medium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sautenkov, Vladimir A.; P. N. Lebedev Institute of Physics, Moscow 119991; Li Hebin
2010-06-15
We have experimentally demonstrated an ultra-dispersive optical prism made from a coherently driven Rb atomic vapor. The prism possesses spectral angular dispersion that is 6 orders of magnitude higher than that of a prism made of optical glass; such angular dispersion allows one to spatially resolve light beams with different frequencies separated by a few kilohertz. The prism operates near the resonant frequency of atomic vapor and its dispersion is optically controlled by a coherent driving field.
Prism fingerprint sensor that uses a holographic optical element
NASA Astrophysics Data System (ADS)
Bahuguna, R. D.; Corboline, Tom
1996-09-01
A prism fingerprint sensor is described that uses a holographic grating glued to a right-angled prism. A light source normally illuminates the hypotenuse side of the prism with the finger pressed against the grating. The ridges and valleys of the finger are sensed on the basis of the principle of total internal reflection. The grating is used essentially to correct the distortion usually present with prism sensors. The quality of the fingerprint is very good: the pores on the ridges can be seen.
Experimental static aerodynamics of a regular hexagonal prism in a low density hypervelocity flow
NASA Technical Reports Server (NTRS)
Guy, R. W.; Mueller, J. N.; Lee, L. P.
1972-01-01
A regular hexagonal prism, having a fineness ratio of 1.67, has been tested in a wind tunnel to determine its static aerodynamic characteristics in a low-density hypervelocity flow. The prism tested was a 1/4-scale model of the graphite heat shield which houses the radioactive fuel for the Viking spacecraft auxiliary power supply. The basic hexagonal prism was also modified to simulate a prism on which ablation of one of the six side flats had occurred. This modified hexagonal prism was tested to determine the effects on the aerodynamic characteristics of a shape change caused by ablation during a possible side-on stable reentry.
PRogram In Support of Moms (PRISM): Development and Beta Testing.
Byatt, Nancy; Pbert, Lori; Hosein, Safiyah; Swartz, Holly A; Weinreb, Linda; Allison, Jeroan; Ziedonis, Douglas
2016-08-01
Most women with perinatal depression do not receive depression treatment. The authors describe the development and beta testing of a new program, PRogram In Support of Moms (PRISM), to improve treatment of perinatal depression in obstetric practices. A multidisciplinary work group of seven perinatal and behavioral health professionals was convened to design, refine, and beta-test PRISM in an obstetric practice. Iterative feedback and problem solving facilitated development of PRISM components, which include provider training and a toolkit, screening procedures, implementation assistance, and access to immediate psychiatric consultation. Beta testing with 50 patients over two months demonstrated feasibility and suggested that PRISM may improve provider screening rates and self-efficacy to address depression. On the basis of lessons learned, PRISM will be enhanced to integrate proactive patient engagement and monitoring into obstetric practices. PRISM may help overcome patient-, provider-, and system-level barriers to managing perinatal depression in obstetric settings.
The Program for Regional and International Shorebird Monitoring (PRISM)
Jonathan Bart; Brad Andres; Stephen Brown; Garry Donaldson; Brian Harrington; Vicky Johnston; Stephanie Jones; Guy Morrison; Susan Skagen
2005-01-01
This report describes the “Program for Regional and International Shorebird Monitoring” (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird...
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine position...
Symmetry Breaking Analysis of Prism Adaptation's Latent Aftereffect
ERIC Educational Resources Information Center
Frank, Till D.; Blau, Julia J. C.; Turvey, Michael T.
2012-01-01
The effect of prism adaptation on movement is typically reduced when the movement at test (prisms off) differs on some dimension from the movement at training (prisms on). Some adaptation is latent, however, and only revealed through further testing in which the movement at training is fully reinstated. Applying a nonlinear attractor dynamic model…
Kuang, Yi; Long, Marcus J C; Zhou, Jie; Shi, Junfeng; Gao, Yuan; Xu, Chen; Hedstrom, Lizbeth; Xu, Bing
2014-10-17
Emerging evidence reveals that prion-like structures play important roles to maintain the well-being of cells. Although self-assembly of small molecules also affords prion-like nanofibrils (PriSM), little is known about the functions and mechanisms of PriSM. Previous works demonstrated that PriSM formed by a dipeptide derivative selectively inhibiting the growth of glioblastoma cells over neuronal cells and effectively inhibiting xenograft tumor in animal models. Here we examine the protein targets, the internalization, and the cytotoxicity pathway of the PriSM. The results show that the PriSM selectively accumulate in cancer cells via macropinocytosis to impede the dynamics of cytoskeletal filaments via promiscuous interactions with cytoskeletal proteins, thus inducing apoptosis. Intriguingly, Tau proteins are able to alleviate the effect of the PriSM, thus protecting neuronal cells. This work illustrates PriSM as a new paradigm for developing polypharmacological agents that promiscuously interact with multiple proteins yet result in a primary phenotype, such as cancer inhibition. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Left-Deviating Prism Adaptation in Left Neglect Patient: Reflexions on a Negative Result
Luauté, Jacques; Jacquin-Courtois, Sophie; O'Shea, Jacinta; Christophe, Laure; Rode, Gilles; Boisson, Dominique; Rossetti, Yves
2012-01-01
Adaptation to right-deviating prisms is a promising intervention for the rehabilitation of patients with left spatial neglect. In order to test the lateral specificity of prism adaptation on left neglect, the present study evaluated the effect of left-deviating prism on straight-ahead pointing movements and on several classical neuropsychological tests in a group of five right brain-damaged patients with left spatial neglect. A group of healthy subjects was also included for comparison purposes. After a single session of exposing simple manual pointing to left-deviating prisms, contrary to healthy controls, none of the patients showed a reliable change of the straight-ahead pointing movement in the dark. No significant modification of attentional paper-and-pencil tasks was either observed immediately or 2 hours after prism adaptation. These results suggest that the therapeutic effect of prism adaptation on left spatial neglect relies on a specific lateralized mechanism. Evidence for a directional effect for prism adaptation both in terms of the side of the visuomanual adaptation and therefore possibly in terms of the side of brain affected by the stimulation is discussed. PMID:23050168
NASA Astrophysics Data System (ADS)
Nguyen, Minh-Hang; Chu, Thi-Xuan; Nguyen, Long; Nguyen, Hai-Binh; Lee, Chun-Wei; Tseng, Fan-Gang; Chen, Te-Chang; Lee, Ming-Chang
2016-11-01
Fabrication of three-dimensional (3D) SU-8 (an epoxy-based negative photoresist from MicroChem) prisms as low-loss couplers for interconnection between optical components, particularly optical fibers and silicon-on-isolator waveguides (SOI WGs), which have mismatched mode sizes, has been investigated. With an interfacial structure formed by a 3D SU-8 prism partly overlaying an SOI WG end with a portion of buried oxide (BOX) removed under the interface, low-loss coupling is ensured and the transmission efficiency can reach 70%. To fabricate these 3D SU-8 prisms, a simple method with two photolithography steps was used for SU-8 hinges and CYTOP (an amorphous fluoropolymer from AGC Chemicals) prism windows, with mild soft and hard bakes, to define the prism profiles with diluted SU-8 filled in the CYTOP prism windows. A buffered oxide etchant is used to remove BOX parts under the interfaces. Some of the fabricated structures were tested, demonstrating the contribution of overlaying SU-8 prisms to the transmission efficiency of optical interconnections between fibers and SOI WGs.
PRISM: Enmeshment of illness and self-schema.
Denton, Fiona; Sharpe, Louise; Schrieber, Leslie
2004-01-01
The Pictorial Representation of Illness and Self Measure (PRISM) is a recently developed tool purported to assess burden of suffering due to illness. The nature of the PRISM task suggests a conceptual link to the illness self-schema construct hypothesised to be present in some individuals with chronic illness. This study investigates the relationship between PRISM and schema as measured by cognitive bias. 43 patients with systemic lupus erythematosus (SLE) completed an information-processing task involving endorsement of positive and negative illness words as descriptors of themselves, followed by free recall of the words. The outcome measures were endorsement and recall bias for negative illness words. Patients also completed the PRISM task and were assessed on other physical and psychological variables. PRISM did not correlate significantly with age, depression, functional impairment or disease activity. In a multiple regression analysis, only recall bias made an independent contribution to PRISM. Illness self-schema appears to play a significant role in determining the way in which SLE patients complete the PRISM task. This is discussed in light of a schema enmeshment model recently proposed in the cognitive bias literature. Copyright 2004 S. Karger AG, Basel
Standardization of motion sickness induced by left-right and up-down reversing prisms
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Vanderploeg, J. M.; Brumley, E. A.; Kolafa, J. J.; Wood, S. J.
1990-01-01
Reversing prisms are known to produce symptoms of motion sickness, and have been used to provide a chronic stimulus for training subjects on symptom recognition and regulation. However, testing procedures with reversing prisms have not been standardized. A set of procedures were evaluated which could be standardized using prisms for provocation and to compare the results between Right/Left Reversing Prisms (R/L-RP) and Up/Down Reversing Prisms (U/D-RP). Fifteen subjects were tested with both types of prisms using a self paced walking course throughout the laboratory with work stations established at specified intervals. The work stations provided tasks requiring eye-hand-foot coordination and various head movements. Comparisons were also made between these prism tests and two other standardized susceptibility tests, the KC-135 parabolic static chair test and the Staircase Velocity Motion Test (SVMT). Two different types of subjective symptom reports were compared. The R/L-RP were significantly more provocative than the U/D-RP. The incidence of motion sickness symptoms for the R/L-RP was similar to the KC-135 parabolic static chair test. Poor correlations were found between the prism tests and the other standardized susceptibility tests, which might indicate that different mechanisms are involved in provoking motion sickness for these different tests.
Activation of the cerebellar cortex and the dentate nucleus in a prism adaptation fMRI study.
Küper, Michael; Wünnemann, Meret J S; Thürling, Markus; Stefanescu, Roxana M; Maderwald, Stefan; Elles, Hans G; Göricke, Sophia; Ladd, Mark E; Timmann, Dagmar
2014-04-01
During prism adaptation two types of learning processes can be distinguished. First, fast strategic motor control responses are predominant in the early course of prism adaptation to achieve rapid error correction within few trials. Second, slower spatial realignment occurs among the misaligned visual and proprioceptive sensorimotor coordinate system. The aim of the present ultra-highfield (7T) functional magnetic resonance imaging (fMRI) study was to explore cerebellar cortical and dentate nucleus activation during the course of prism adaptation in relation to a similar visuomotor task without prism exposure. Nineteen young healthy participants were included into the study. Recently developed normalization procedures were applied for the cerebellar cortex and the dentate nucleus. By means of subtraction analysis (early prism adaptation > visuomotor, early prism adaptation > late prism adaptation) we identified ipsilateral activation associated with strategic motor control responses within the posterior cerebellar cortex (lobules VIII and IX) and the ventro-caudal dentate nucleus. During the late phase of adaptation we observed pronounced activation of posterior parts of lobule VI, although subtraction analyses (late prism adaptation > visuomotor) remained negative. These results are in good accordance with the concept of a representation of non-motor functions, here strategic control, within the ventro-caudal dentate nucleus. Copyright © 2013 Wiley Periodicals, Inc.
PRISM 3: expanded prediction of natural product chemical structures from microbial genomes
Skinnider, Michael A.; Merwin, Nishanth J.; Johnston, Chad W.
2017-01-01
Abstract Microbial natural products represent a rich resource of pharmaceutically and industrially important compounds. Genome sequencing has revealed that the majority of natural products remain undiscovered, and computational methods to connect biosynthetic gene clusters to their corresponding natural products therefore have the potential to revitalize natural product discovery. Previously, we described PRediction Informatics for Secondary Metabolomes (PRISM), a combinatorial approach to chemical structure prediction for genetically encoded nonribosomal peptides and type I and II polyketides. Here, we present a ground-up rewrite of the PRISM structure prediction algorithm to derive prediction of natural products arising from non-modular biosynthetic paradigms. Within this new version, PRISM 3, natural product scaffolds are modeled as chemical graphs, permitting structure prediction for aminocoumarins, antimetabolites, bisindoles and phosphonate natural products, and building upon the addition of ribosomally synthesized and post-translationally modified peptides. Further, with the addition of cluster detection for 11 new cluster types, PRISM 3 expands to detect 22 distinct natural product cluster types. Other major modifications to PRISM include improved sequence input and ORF detection, user-friendliness and output. Distribution of PRISM 3 over a 300-core server grid improves the speed and capacity of the web application. PRISM 3 is available at http://magarveylab.ca/prism/. PMID:28460067
Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia
Bowers, Alex R.; Keeney, Karen; Peli, Eli
2013-01-01
Objective To evaluate the efficacy of real relative to sham peripheral prism glasses for patients with complete homonymous hemianopia and without visual neglect. Methods Patients recruited at 13 clinics were allocated by minimization into a double-masked, crossover trial with two groups. One group received real (57Δ) oblique and sham (≤ 5Δ) horizontal prisms; the other received real horizontal and sham oblique, in counterbalanced order. A masked data collector at each clinic administered questionnaires after each 4-week crossover period. Main outcome measure The primary outcome was the overall difference, across the two periods of the crossover, between the proportion of participants who wanted to continue with (said “yes” to) real prisms and the proportion who said yes to sham prisms. The secondary outcome was the difference in perceived mobility improvement between real and sham prisms. Results Of 73 patients randomized, 61 completed the crossover. A significantly higher proportion said yes to real than sham prisms (64% vs. 36%; odds ratio 5.3, 95% CI 1.8 to 21.0). Participants who continued wear after 6 months reported greater improvement in mobility with real than sham prisms at crossover end (p=0.002); participants who discontinued wear reported no difference. Conclusion Real peripheral prism glasses were more helpful for obstacle avoidance when walking than sham glasses, with no differences between the horizontal and oblique designs. Applications to clinical practice Peripheral prism glasses provide a simple and inexpensive mobility rehabilitation intervention for hemianopia. PMID:24201760
Is the aligning prism measured with the Mallett unit correlated with fusional vergence reserves?
Conway, Miriam L; Thomas, Jennifer; Subramanian, Ahalya
2012-01-01
The Mallett Unit is a clinical test designed to detect the fixation disparity that is most likely to occur in the presence of a decompensated heterophoria. It measures the associated phoria, which is the "aligning prism" needed to nullify the subjective disparity. The technique has gained widespread acceptance within professions such as optometry, for investigating suspected cases of decompensating heterophoria; it is, however, rarely used by orthoptists and ophthalmologists. The aim of this study was to investigate whether fusional vergence reserves, measured routinely by both orthoptists and ophthalmologists to detect heterophoria decompensation, were correlated with aligning prism (associated phoria) in a normal clinical population. Aligning prism (using the Mallett Unit) and fusional vergence reserves (using a prism bar) were measured in 500 participants (mean 41.63 years; standard deviation 11.86 years) at 40 cm and 6 m. At 40 cm a strong correlation (p<0.001) between base in aligning prism (Exo FD) and positive fusional reserves was found. Of the participants with zero aligning prism 30% had reduced fusional reserves. At 6 m a weak correlation between base out aligning prism (Eso FD) and negative fusional reserves was found to break (p = 0.01) and to recovery (p = 0.048). Of the participants with zero aligning prism 12% reported reduced fusional reserves. For near vision testing, the strong inverse correlation between base in aligning prism (Exo FD) and fusional vergence reserves supports the notion that both measures are indicators of decompensation of heterophoria. For distance vision testing and for those patients reporting zero aligning prism further research is required to determine why the relationship appears to be weak/non-existent?
Sayed, Heba A; Ali, Amany M; Elzembely, Mahmoud M
2017-11-23
Pediatric Risk of Mortality Score (PRISM III-12) is a physiology-based predictor for risk of mortality. We conducted prospective study from January 1, 2014 to 2015 in pediatric oncology intensive care unit (POICU) at South Egypt Cancer Institute, Egypt to explore the ability of 1st PRISM III-12 to predict the risk of mortality in critically ill cancer patients and the ability of serial PRISM III measured every 72 hours to follow-up the patients' clinical condition during POICU stay. In total, 123 (78 males) children were included. Median age was 5 years (1 to 15 y). Death rate was 20%. 1st PRISM III-12 mean was 19 (0 to 61). The mean 1st PRISM III-12 for survivors was significantly higher compared with nonsurvivors (15 vs. 37 respectively; P<0.001). 1st PRISM III-12 mean was significantly correlated to the reasons for admission and organ failures' number (P<0.001 and <0.001). 1st PRISM III-12 correlated weakly positive with the length of stay (r=0.2; P=0.024). Receiver operator curve for 1st PRISM III-12 was 0.913 (95% confidence interval, 0.85-0.98; P<0.001). Decline in serial PRISM III was significantly correlated with favorable (survivor) outcome (P<0.001). We concluded that PRISM III-12 can be used effectively in predicting the risk of mortality and following the clinical condition of patients during POICU stay.
Successful treatment of diplopia with prism improves health-related quality of life
Hatt, Sarah R.; Leske, David A.; Liebermann, Laura; Holmes, Jonathan M.
2014-01-01
Purpose To report change in strabismus-specific health-related quality of life (HRQOL) following treatment with prism. Design Retrospective cross-sectional study Methods Thirty-four patients with diplopia (median age 63, range 14 to 84 years) completed the Adult Strabismus-20 questionnaire (100 to 0, best to worst HRQOL) and a diplopia questionnaire in a clinical practice before prism and in prism correction. Before prism, diplopia was “sometimes” or worse for reading and/or straight ahead distance. Prism treatment success was defined as diplopia rated “never” or “rarely” on the Diplopia Questionnaire for reading and straight ahead distance. Failure was defined as worsening or no change in diplopia. For both successes and failures, mean Adult Strabismus -20 scores were compared pre-prism and in prism correction. Each of the four Adult Strabismus -20 domains (Self-perception, Interactions, Reading function and General function) were analyzed separately. Results Twenty-three (68%) of 34 were successes and 11 (32%) were failures. For successes, Reading Function improved from 57 ± 27 (SD) before prism to 69 ± 27 in-prism correction (difference 12 ± 20, 95% CI 3.2 to 20.8, P=0.02) and General Function improved from 66 ± 25 to 80 ± 18 (difference 14 ± 22, 95% CI 5.0 to 23.6, P=0.003). Self-perception and Interaction domains remained unchanged (P>0.2). For failures there was no significant change in Adult Strabismus -20 score on any domain (P>0.4). Conclusions Successful correction of diplopia with prism is associated with improvement in strabismus-specific HRQOL, specifically reading function and general function. PMID:24561171
Sensky, Tom; Büchi, Stefan
2016-01-01
PRISM (the Pictorial Representation of Illness and Self Measure) is a novel, simple visual instrument. Its utility was initially discovered serendipitously, but has been validated as a quantitative measure of suffering. Recently, new applications for different purposes, even in non-health settings, have encouraged further exploration of how PRISM works, and how it might be applied. This review will summarise the results to date from applications of PRISM and propose a generic conceptualisation of how PRISM works which is consistent with all these applications. A systematic review, in the form of a qualitative evidence synthesis, was carried out of all available published data on PRISM. Fifty-two publications were identified, with a total of 8254 participants. Facilitated by simple instructions, PRISM has been used with patient groups in a variety of settings and cultures. As a measure of suffering, PRISM has, with few exceptions, behaved as expected according to Eric Cassell's seminal conceptualisation of suffering. PRISM has also been used to assess beliefs about or attitudes to stressful working conditions, interpersonal relations, alcohol consumption, and suicide, amongst others. This review supports PRISM behaving as a visual metaphor of the relationship of objects (eg 'my illness') to a subject (eg 'myself') in a defined context (eg 'my life at the moment'). As a visual metaphor, it is quick to complete and yields personally salient information. PRISM is likely to have wide applications in assessing beliefs, attitudes, and decision-making, because of its properties, and because it yields both quantitative and qualitative data. In medicine, it can serve as a generic patient-reported outcome measure. It can serve as a tool for representational guidance, can be applied to developing strategies visually, and is likely to have applications in coaching, psychological assessment and therapeutic interventions.
Goldmann tonometry tear film error and partial correction with a shaped applanation surface.
McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M
2018-01-01
The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.
Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia.
Bowers, Alex R; Keeney, Karen; Peli, Eli
2014-02-01
There is a major lack of randomized controlled clinical trials evaluating the efficacy of prismatic treatments for hemianopia. Evidence for their effectiveness is mostly based on anecdotal case reports and open-label evaluations without a control condition. To evaluate the efficacy of real relative to sham peripheral prism glasses for patients with complete homonymous hemianopia. Double-masked, randomized crossover trial at 13 study sites, including the Peli laboratory at Schepens Eye Research Institute, 11 vision rehabilitation clinics in the United States, and 1 in the United Kingdom. Patients were 18 years or older with complete homonymous hemianopia for at least 3 months and without visual neglect or significant cognitive decline. Patients were allocated by minimization into 2 groups. One group received real (57-prism diopter) oblique and sham (<5-prism diopter) horizontal prisms; the other received real horizontal and sham oblique, in counterbalanced order. Each crossover period was 4 weeks. The primary outcome was the overall difference, across the 2 periods of the crossover, between the proportion of participants who wanted to continue with (said yes to) real prisms and the proportion who said yes to sham prisms. The secondary outcome was the difference in perceived mobility improvement between real and sham prisms. Of 73 patients randomized, 61 completed the crossover. A significantly higher proportion said yes to real than sham prisms (64% vs 36%; odds ratio, 5.3; 95% CI, 1.8-21.0). Participants who continued wear after 6 months reported greater improvement in mobility with real than sham prisms at crossover end (P = .002); participants who discontinued wear reported no difference. Real peripheral prism glasses were more helpful for obstacle avoidance when walking than sham glasses, with no differences between the horizontal and oblique designs. Peripheral prism glasses provide a simple and inexpensive mobility rehabilitation intervention for hemianopia. clinicaltrials.gov Identifier: NCT00494676.
Kinematic markers dissociate error correction from sensorimotor realignment during prism adaptation.
O'Shea, Jacinta; Gaveau, Valérie; Kandel, Matthieu; Koga, Kazuo; Susami, Kenji; Prablanc, Claude; Rossetti, Yves
2014-03-01
This study investigated the motor control mechanisms that enable healthy individuals to adapt their pointing movements during prism exposure to a rightward optical shift. In the prism adaptation literature, two processes are typically distinguished. Strategic motor adjustments are thought to drive the pattern of rapid endpoint error correction typically observed during the early stage of prism exposure. This is distinguished from so-called 'true sensorimotor realignment', normally measured with a different pointing task, at the end of prism exposure, which reveals a compensatory leftward 'prism after-effect'. Here, we tested whether each mode of motor compensation - strategic adjustments versus 'true sensorimotor realignment' - could be distinguished, by analyzing patterns of kinematic change during prism exposure. We hypothesized that fast feedforward versus slower feedback error corrective processes would map onto two distinct phases of the reach trajectory. Specifically, we predicted that feedforward adjustments would drive rapid compensation of the initial (acceleration) phase of the reach, resulting in the rapid reduction of endpoint errors typically observed early during prism exposure. By contrast, we expected visual-proprioceptive realignment to unfold more slowly and to reflect feedback influences during the terminal (deceleration) phase of the reach. The results confirmed these hypotheses. Rapid error reduction during the early stage of prism exposure was achieved by trial-by-trial adjustments of the motor plan, which were proportional to the endpoint error feedback from the previous trial. By contrast, compensation of the terminal reach phase unfolded slowly across the duration of prism exposure. Even after 100 trials of pointing through prisms, adaptation was incomplete, with participants continuing to exhibit a small rightward shift in both the reach endpoints and in the terminal phase of reach trajectories. Individual differences in the degree of adaptation of the terminal reach phase predicted the magnitude of prism after-effects. In summary, this study identifies distinct kinematic signatures of fast strategic versus slow sensorimotor realignment processes, which combine to adjust motor performance to compensate for a prismatic shift. © 2013 Elsevier Ltd. All rights reserved.
The effect of prism on preferred retinal locus.
Lewerenz, David; Blanco, Daniel; Ratzlaff, Chase; Zodrow, Ashley
2018-03-01
Whether prism, especially base-up prism, affects the area of the retina used for fixation in a patient with central scotoma has been a controversial subject for 35 years. Our pilot study employed microperimetry to evaluate the effect of base-up prism on the fixation locus, or preferred retinal locus (PRL), in subjects with central scotoma. We used a microperimeter to assess the PRL in 13 visually impaired subjects with central scotoma under four conditions: no lens, a lens with no prism (control lens), 6 Δ base-up, and 10 Δ base-up. The PRL was measured in degrees in horizontal and vertical co-ordinates from the centre of the optic disc using graphical analysis. The PRL with the control lens was not significantly different from the PRL with no lens. The preferred retinal loci with the two powers of prism were compared to the control lens and showed a superior shift in 22 of 26 cases (84.6 per cent). The amount of movement was significantly different from zero (p = 0.001 for 6 Δ and p = 0.004 for 10 Δ ). The vertical movement with the 10 Δ prism (1.73 ± 1.73 degrees) was not significantly greater (p = 0.562) than with the 6 Δ prism (1.37 ± 1.08 degrees). The shift was significantly less than the prism powers used (p < 0.001), and the amount of vertical relocation was not significantly different from the amount of horizontal movement. In our study, base-up prism appears to shift the PRL in the direction of the prism base most of the time, but our findings do not support the use of prism as a way of predictably relocating the PRL. More study is indicated to evaluate whether such a small shift is clinically or functionally significant. © 2017 Optometry Australia.
Occurrence of rhombic prisms in some structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyman, H.
1976-02-01
An ideal rhombic prism is defined as two regular trigonal prisms sharing a square face. In terms of such rhombic prisms, the structures of CrB and ..cap alpha..-PdCl/sub 2/, U/sub 3/Si/sub 2/ and Au/sub 3/Zn, and CoCa/sub 3/ and PdS are easily described. A network of rhombic prisms, with cubic symmetry, is also used to describe the structures of CoAs/sub 3/, Sc(OH)/sub 3/, WAl/sub 12/, and NaMn/sub 7/O/sub 12/.
Wollaston prism phase-stepping point diffraction interferometer and method
Rushford, Michael C.
2004-10-12
A Wollaston prism phase-stepping point diffraction interferometer for testing a test optic. The Wollaston prism shears light into reference and signal beams, and provides phase stepping at increased accuracy by translating the Wollaston prism in a lateral direction with respect to the optical path. The reference beam produced by the Wollaston prism is directed through a pinhole of a diaphragm to produce a perfect spherical reference wave. The spherical reference wave is recombined with the signal beam to produce an interference fringe pattern of greater accuracy.
Pointing error analysis of Risley-prism-based beam steering system.
Zhou, Yuan; Lu, Yafei; Hei, Mo; Liu, Guangcan; Fan, Dapeng
2014-09-01
Based on the vector form Snell's law, ray tracing is performed to quantify the pointing errors of Risley-prism-based beam steering systems, induced by component errors, prism orientation errors, and assembly errors. Case examples are given to elucidate the pointing error distributions in the field of regard and evaluate the allowances of the error sources for a given pointing accuracy. It is found that the assembly errors of the second prism will result in more remarkable pointing errors in contrast with the first one. The pointing errors induced by prism tilt depend on the tilt direction. The allowances of bearing tilt and prism tilt are almost identical if the same pointing accuracy is planned. All conclusions can provide a theoretical foundation for practical works.
Clark, Robert A.
2015-01-01
Vertical fusional vergence (VFV) normally compensates for slight vertical heterophorias. We employed magnetic resonance imaging to clarify extraocular muscle contributions to VFV induced by monocular two-prism diopter (1.15°) base-up prism in 14 normal adults. Fusion during prism viewing requires monocular infraduction. Scans were repeated without prism, and with prism shifted contralaterally. Contractility indicated by morphometric indexes was separately analyzed in medial and lateral vertical rectus and superior oblique (SO) putative compartments, and superior and inferior horizontal rectus extraocular muscle putative compartments, but in the whole inferior oblique (IO). Images confirmed appropriate VFV that was implemented by the inferior rectus (IR) medial compartment contracting ipsilateral and relaxing contralateral to prism. There was no significant contractility in the IR lateral compartment. The superior but not inferior lateral rectus (LR) compartment contracted significantly in the prism viewing eye, but not contralateral to prism. The IO contracted ipsilateral but not contralateral to the prism. In the infraducting eye, the SO medial compartment relaxed significantly, while the lateral compartment was unchanged; contralateral to prism, the SO lateral compartment contracted, while the medial compartment was unchanged. There was no contractility in the superior or medial rectus muscles in either eye. There was no globe retraction. We conclude that the vertical component of VFV is primarily implemented by IR medial compartment contraction. Since appropriate vertical rotation is not directly implemented, or is opposed, by associated differential LR and SO compartmental activity, and IO contraction, these actions probably implement a torsional component of VFV. PMID:25589593
Optimization of SPR signals: Monitoring the physical structures and refractive indices of prisms
NASA Astrophysics Data System (ADS)
Maisarah Mukhtar, Wan; Halim, Razman Mohd; Hassan, Hazirah
2017-11-01
Surface plasmon resonance (SPR) can only be achieved if sufficient energy is provided at the boundary between metal and dielectric. An employment of prism as a light coupler by using Kretschmann configuration is one of the alternative for the production of adequate energy to be generated as surface plasmon polaritons (SPP). This work is carried out to investigate the effect of physical structure of the prism and its refractive index to the excitation of SPPs. A 50nm gold thin metal film with dielectric constant of ɛ=-12.45i+1.3 was deposited on the hypotenuse surface of the prisms. The physical structures of the prisms were varied such as triangular, conical, hemispherical and half cylindrical. These prisms were classified into two types of refractive indices (RI), namely n=1.51(type BK7) and n=1.77(type SF11). Based on SPR curve analyses, we discovered that strong SPR signals which consist of 82.98% photons were excited as SPPs can be obtained by using type-BK7 prism with physical structures of hemispherical or half cylindrical. From the view of selectivity ability as sensors, the usage of type-SF11 prisms (half cylindrical and hemispherical) able to enhance this impressive feature in which sharp SPR curves with small FWHM values were obtained. In conclusion, apart from properties of thin film materials, the physical structure of prisms and their RI values play crucial roles to obtain optimum SPR signal. High sensitivity SPR sensor can be established with the appointment of type-BK7 prisms (hemispherical or half cylindrical shape) as light couplers.
Maier, Felix M; Schaeffel, Frank
2013-07-24
To find out whether adaptation to a vertical prism involves more than fusional vertical eye movements. Adaptation to a vertical base-up 3 prism diopter prism was measured in a custom-programmed Maddox test in nine visually normal emmetropic subjects (mean age 27.0 ± 2.8 years). Vertical eye movements were binocularly measured in six of the subjects with a custom-programmed binocular video eye tracker. In the Maddox test, some subjects adjusted the perceived height as expected from the power of the prism while others appeared to ignore the prism. After 15 minutes of adaptation, the interocular difference in perceived height was reduced by on average 51% (from 0.86°-0.44°). The larger the initially perceived difference in height in a subject, the larger the amplitude of adaptation was. Eye tracking showed that the prism generated divergent vertical eye movements of 1.2° on average, which was less than expected from its power. Differences in eye elevation were maintained as long as the prism was in place. Small angles of lateral head tilt generated large interocular differences in eye elevation, much larger than the effects introduced by the prism. Vertical differences in retinal image height were compensated by vertical fusional eye movements but some subjects responded poorly to a vertical prism in both experiments; fusional eye movements were generally too small to realign both foveae with the fixation target; and the prism adaptation in the Maddox test was fully explained by the changes in vertical eye position, suggesting that no further adaptational mechanism may be involved.
Peripheral Prism Glasses: Effects of Dominance, Suppression and Background
Ross, Nicole C.; Bowers, Alex R.; Optom, M.C.; Peli, Eli
2012-01-01
Purpose Unilateral peripheral prisms for homonymous hemianopia (HH) place different images on corresponding peripheral retinal points, a rivalrous situation in which local suppression of the prism image could occur and thus limit device functionality. Detection with peripheral prisms has primarily been evaluated using conventional perimetry where binocular rivalry is unlikely to occur. We quantified detection over more visually complex backgrounds and examined the effects of ocular dominance. Methods Detection rates of 8 participants with HH or quadranopia and normal binocularity wearing unilateral peripheral prism glasses were determined for static perimetry targets briefly presented in the prism expansion area (in the blind hemifield) and the seeing hemifield, under monocular and binocular viewing, over uniform gray and more complex patterned backgrounds. Results Participants with normal binocularity had mixed sensory ocular dominance, demonstrated no difference in detection rates when prisms were fitted on the side of the HH or the opposite side (p>0.2), and had detection rates in the expansion area that were not different for monocular and binocular viewing over both backgrounds (p>0.4). However, two participants with abnormal binocularity and strong ocular dominance demonstrated reduced detection in the expansion area when prisms were fitted in front of the non-dominant eye. Conclusions We found little evidence of local suppression of the peripheral prism image for HH patients with normal binocularity. However, in cases of strong ocular dominance, consideration should be given to fitting prisms before the dominant eye. Although these results are promising, further testing in more realistic conditions including image motion is needed. PMID:22885783
Use of prism adaptation in children with unilateral brain lesion: Is it feasible?
Riquelme, Inmaculada; Henne, Camille; Flament, Benoit; Legrain, Valéry; Bleyenheuft, Yannick; Hatem, Samar M
2015-01-01
Unilateral visuospatial deficits have been observed in children with brain damage. While the effectiveness of prism adaptation for treating unilateral neglect in adult stroke patients has been demonstrated previously, the usefulness of prism adaptation in a pediatric population is still unknown. The present study aims at evaluating the feasibility of prism adaptation in children with unilateral brain lesion and comparing the validity of a game procedure designed for child-friendly paediatric intervention, with the ecological task used for prism adaptation in adult patients. Twenty-one children with unilateral brain lesion randomly were assigned to a prism group wearing prismatic glasses, or a control group wearing neutral glasses during a bimanual task intervention. All children performed two different bimanual tasks on randomly assigned consecutive days: ecological tasks or game tasks. The efficacy of prism adaptation was measured by assessing its after-effects with visual open loop pointing (visuoproprioceptive test) and subjective straight-ahead pointing (proprioceptive test). Game tasks and ecological tasks produced similar after-effects. Prismatic glasses elicited a significant shift of visuospatial coordinates which was not observed in the control group. Prism adaptation performed with game tasks seems an effective procedure to obtain after-effects in children with unilateral brain lesion. The usefulness of repetitive prism adaptation sessions as a therapeutic intervention in children with visuospatial deficits and/or neglect, should be investigated in future studies. Copyright © 2015 Elsevier Ltd. All rights reserved.
PRISM 3: expanded prediction of natural product chemical structures from microbial genomes.
Skinnider, Michael A; Merwin, Nishanth J; Johnston, Chad W; Magarvey, Nathan A
2017-07-03
Microbial natural products represent a rich resource of pharmaceutically and industrially important compounds. Genome sequencing has revealed that the majority of natural products remain undiscovered, and computational methods to connect biosynthetic gene clusters to their corresponding natural products therefore have the potential to revitalize natural product discovery. Previously, we described PRediction Informatics for Secondary Metabolomes (PRISM), a combinatorial approach to chemical structure prediction for genetically encoded nonribosomal peptides and type I and II polyketides. Here, we present a ground-up rewrite of the PRISM structure prediction algorithm to derive prediction of natural products arising from non-modular biosynthetic paradigms. Within this new version, PRISM 3, natural product scaffolds are modeled as chemical graphs, permitting structure prediction for aminocoumarins, antimetabolites, bisindoles and phosphonate natural products, and building upon the addition of ribosomally synthesized and post-translationally modified peptides. Further, with the addition of cluster detection for 11 new cluster types, PRISM 3 expands to detect 22 distinct natural product cluster types. Other major modifications to PRISM include improved sequence input and ORF detection, user-friendliness and output. Distribution of PRISM 3 over a 300-core server grid improves the speed and capacity of the web application. PRISM 3 is available at http://magarveylab.ca/prism/. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
NASA Technical Reports Server (NTRS)
Breckinridge, J. B.; Page, N. A.; Rodgers, J. M.
1985-01-01
Efficient linear dispersive element for spectrometer instruments achieved using several different glasses in multiple-element prism. Good results obtained in both two-and three-element prisms using variety of different glass materials.
Goedert, Kelly M; Chen, Peii; Foundas, Anne L; Barrett, A M
2018-03-20
Spatial neglect commonly follows right hemisphere stroke. It is defined as impaired contralesional stimulus detection, response, or action, causing functional disability. While prism adaptation treatment is highly promising to promote functional recovery of spatial neglect, not all individuals respond. Consistent with a primary effect of prism adaptation on spatial movements, we previously demonstrated that functional improvement after prism adaptation treatment is linked to frontal lobe lesions. However, that study was a treatment-only study with no randomised control group. The current study randomised individuals with spatial neglect to receive 10 days of prism adaptation treatment or to receive only standard care (control group). Replicating our earlier results, we found that the presence of frontal lesions moderated response to prism adaptation treatment: among prism-treated patients, only those with frontal lesions demonstrated functional improvements in their neglect symptoms. Conversely, among individuals in the standard care control group, the presence of frontal lesions did not modify recovery. These results suggest that further research is needed on how frontal lesions may predict response to prism adaptation treatment. Additionally, the results help elucidate the neural network involved in spatial movement and could be used to aid decisions about treatment.
Rhomboid prism pair for rotating the plane of parallel light beams
NASA Technical Reports Server (NTRS)
Orloff, K. L. (Inventor); Yanagita, H.
1982-01-01
An optical system is described for rotating the plane defined by a pair of parallel light beams. In one embodiment a single pair of rhomboid prisms have their respective input faces disposed to receive the respective input beams. Each prism is rotated about an axis of revolution coaxial with each of the respective input beams by means of a suitable motor and gear arrangement to cause the plane of the parallel output beams to be rotated relative to the plane of the input beams. In a second embodiment, two pairs of rhomboid prisms are provided. In a first angular orientation of the output beams, the prisms merely decrease the lateral displacement of the output beams in order to keep in the same plane as the input beams. In a second angular orientation of the prisms, the input faces of the second pair of prisms are brought into coincidence with the input beams for rotating the plane of the output beams by a substantial angle such as 90 deg.
A study on suppressing transmittance fluctuations for air-gapped Glan-type polarizing prisms
NASA Astrophysics Data System (ADS)
Zhang, Chuanfa; Li, Dailin; Zhu, Huafeng; Li, Chuanzhi; Jiao, Zhiyong; Wang, Ning; Xu, Zhaopeng; Wang, Xiumin; Song, Lianke
2018-05-01
Light intensity transmittance is a key parameter for the design of polarizing prisms, while sometimes its experimental curves based on spatial incident angle presents periodical fluctuations. Here, we propose a novel method for completely suppressing these fluctuations via setting a glued error angle in the air gap of Glan-Taylor prisms. The proposal consists of: an accurate formula of the intensity transmittance for Glan-Taylor prisms, a numerical simulation and a contrast experiment of Glan-Taylor prisms for analyzing the causes of the fluctuations, and a simple method for accurately measuring the glued error angle. The result indicates that when the setting glued error angle is larger than the critical angle for a certain polarizing prism, the fluctuations can be completely suppressed, and a smooth intensity transmittance curve can be obtained. Besides, the critical angle in the air gap for suppressing the fluctuations is decreased with the increase of beam spot size. This method has the advantage of having less demand for the prism position in optical systems.
Compact cross-dispersion device based on a prism and a plane transmission grating
NASA Astrophysics Data System (ADS)
Yang, Qinghua; Wang, Weiqiang
2018-05-01
This paper presents a cross-dispersion prism-grating device using a plane transmission grating attached directly to a prism, which is different from traditional cross-dispersion grating-prism systems that are based on the reflection grating. Unlike conventional direct-vision grism or constant-dispersion grism in which both the prism and grating have the same dispersion direction, for this device the dispersion directions of the prism and grating are different. The analytical expressions for the cross-dispersion of this device are derived in detail and the formulas of the footprint of the dispersed spectra are given. The numerical results and ray-tracing simulations by ZEMAX are shown. The device provides a compact, small-sized and broadband cross-dispersion device used for the medium resolution spectrometer.
Device for magneto-optic signal detection with a small crystal prism.
Saito, K; Sato, S; Shino, K; Taniguchi, T
2000-03-10
A device made of a birefringent crystal for signal detection of magneto-optic (MO) disks is presented. The light beam from a MO disk is separated into two orthogonally polarized components at the surface of a birefringent prism. After these two components are reflected by the top and the bottom surfaces of the prism inside, at the detector they become sufficiently separated from each other for discrete detection, even though the prism is small. A method for calculating the light intensities and the positions of focused beams in a birefringent prism and the results of a fundamental experiment are presented.
NASA Astrophysics Data System (ADS)
Smith, G. L.; McNeill, L. C.; Henstock, T.; Bull, J. M.
2011-12-01
The Makran subduction zone is the widest accretionary prism in the world (~400km), generated by convergence between the Arabian and Eurasian tectonic plates. It represents a global end-member, with a 7km thick incoming sediment section. Accretionary prisms have traditionally been thought to be aseismic due to the presence of unconsolidated sediment and elevated basal pore pressures. The seismogenic potential of the Makran subduction zone is unclear, despite a Mw 8.1 earthquake in 1945 that may have been located on the plate boundary beneath the prism. In this study, a series of imbricate landward dipping (seaward verging) thrust faults have been interpreted across the submarine prism (outer 70 km) using over 6000km of industry multichannel seismic data and bathymetric data. A strong BSR (bottom simulating reflector) is present throughout the prism (excluding the far east). An unreflective décollement is interpreted from the geometry of the prism thrusts. Two major sedimentary units are identified in the input section, the lower of which contains the extension of the unreflective décollement surface. Between 60%-100% of the input section is currently being accreted. The geometry of piggy-back basin stratigraphy shows that the majority of thrusts, including those over 50km from the trench, are recently active. Landward thrusts show evidence for reactivation after periods of quiescence. Negative polarity fault plane reflectors are common in the frontal thrusts and in the eastern prism, where they may be related to increased fault activity and fluid expulsion, and are rarer in older landward thrusts. Significant NE-SW trending basement structures (The Murray Ridge and Little Murray Ridge) on the Arabian plate intersect the deformation front and affect sediment input to the subduction zone. Prism taper and structure are apparently primarily controlled by sediment supply and the secondary influence of subducting basement ridges. The thick, likely distal, sediment section in the west produces a prism with a simple imbricate structure. As basement depth is reduced over the Little Murray Ridge, the accretionary prism structure (fault spacing and deformation front position) changes. In the east, proximity to the Murray Ridge and triple junction is expressed through a reduction in prism width and reduced fault activity. The resulting prism structure and morphology can ultimately be used to assess likely sediment properties and hence seismic potential at the plate boundary.
Transforming White Light into Rainbows: Segmentation Strategies for Successful School Tax Elections
ERIC Educational Resources Information Center
Senden, J. Bradford; Lifto, Don E.
2009-01-01
In the late 1600s, British physicist Sir Isaac Newton first demonstrated refraction and dispersion in a triangular prism. He discovered that a prism could decompose white light into a spectrum. Hold a prism up to the light at the correct angle and white light magically splits into vivid colors of the rainbow! So what do prisms and rainbows have to…
Sensky, Tom; Büchi, Stefan
2016-01-01
Background PRISM (the Pictorial Representation of Illness and Self Measure) is a novel, simple visual instrument. Its utility was initially discovered serendipitously, but has been validated as a quantitative measure of suffering. Recently, new applications for different purposes, even in non-health settings, have encouraged further exploration of how PRISM works, and how it might be applied. This review will summarise the results to date from applications of PRISM and propose a generic conceptualisation of how PRISM works which is consistent with all these applications. Methods A systematic review, in the form of a qualitative evidence synthesis, was carried out of all available published data on PRISM. Results Fifty-two publications were identified, with a total of 8254 participants. Facilitated by simple instructions, PRISM has been used with patient groups in a variety of settings and cultures. As a measure of suffering, PRISM has, with few exceptions, behaved as expected according to Eric Cassell’s seminal conceptualisation of suffering. PRISM has also been used to assess beliefs about or attitudes to stressful working conditions, interpersonal relations, alcohol consumption, and suicide, amongst others. Discussion This review supports PRISM behaving as a visual metaphor of the relationship of objects (eg ‘my illness’) to a subject (eg ‘myself’) in a defined context (eg ‘my life at the moment’). As a visual metaphor, it is quick to complete and yields personally salient information. PRISM is likely to have wide applications in assessing beliefs, attitudes, and decision-making, because of its properties, and because it yields both quantitative and qualitative data. In medicine, it can serve as a generic patient-reported outcome measure. It can serve as a tool for representational guidance, can be applied to developing strategies visually, and is likely to have applications in coaching, psychological assessment and therapeutic interventions. PMID:27214024
Do dissociated or associated phoria predict the comfortable prism?
Otto, Joanna M. N.; Kromeier, Miriam; Bach, Michael
2008-01-01
Background Dissociated and associated phoria are measures of latent strabismus under artificial viewing conditions. We examined to what extent dissociated and associated phoria predict the “comfortable prism”, i.e. the prism that appears most comfortable under natural viewing conditions. Methods For associated phoria, a configuration resembling the Mallett test was employed: both eyes were presented with a fixation cross, surrounded by fusionable objects. Nonius lines served as monocular markers. For dissociated phoria, the left eye was presented with all the Mallett elements, while only a white spot was presented to the right eye. To determine the comfortable prism, all the Mallett elements, including the Nonius lines, were shown to both eyes. In each of the three tests, the observer had to adjust a pair of counterrotating prisms. To avoid any (possibly prejudiced) influence of the experimenter, the prismatic power was recorded with a potentiometer. Twenty non-strabismic subjects with a visual acuity of ≥1.0 in each eye were examined. Results The range of the intertrial mean was for dissociated phoria from +9.3 eso to −5.9 cm/m exo, for associated phoria from +11.2 eso to −3.3 cm/m exo, and for the comfortable prism from +4.8 eso to −4.1 cm/m exo (cm/m = prism dioptre). In most observers, the phoria parameters differed greatly from the comfortable prism. On average, the phoria values were shifted about 2 cm/m towards the eso direction in relation to the comfortable prism (associated phoria not less than dissociated phoria). Conclusions The deviation of both, dissociated and associated phoria, from the comfortable prism suggests that the abnormal viewing conditions under which the phoria parameters are determined induce artefacts. Accordingly, the findings cast doubt on current textbook recommendations to use dissociated or associated phoria as a basis for therapeutic prisms. Rather, patients should be allowed to determine their comfortable prism under natural viewing conditions. PMID:18379816
Prism adaptation does not alter configural processing of faces
Bultitude, Janet H.; Downing, Paul E.; Rafal, Robert D.
2013-01-01
Patients with hemispatial neglect (‘neglect’) following a brain lesion show difficulty responding or orienting to objects and events on the left side of space. Substantial evidence supports the use of a sensorimotor training technique called prism adaptation as a treatment for neglect. Reaching for visual targets viewed through prismatic lenses that induce a rightward shift in the visual image results in a leftward recalibration of reaching movements that is accompanied by a reduction of symptoms in patients with neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Interestingly, prism adaptation can also alter aspects of non-lateralised spatial attention. We previously demonstrated that prism adaptation alters the extent to which neglect patients and healthy participants process local features versus global configurations of visual stimuli. Since deficits in non-lateralised spatial attention are thought to contribute to the severity of neglect symptoms, it is possible that the effect of prism adaptation on these deficits contributes to its efficacy. This study examines the pervasiveness of the effects of prism adaptation on perception by examining the effect of prism adaptation on configural face processing using a composite face task. The composite face task is a persuasive demonstration of the automatic global-level processing of faces: the top and bottom halves of two familiar faces form a seemingly new, unknown face when viewed together. Participants identified the top or bottom halves of composite faces before and after prism adaptation. Sensorimotor adaptation was confirmed by significant pointing aftereffect, however there was no significant change in the extent to which the irrelevant face half interfered with processing. The results support the proposal that the therapeutic effects of prism adaptation are limited to dorsal stream processing. PMID:25110574
An optofluidic prism tuned by two laminar flows.
Xiong, S; Liu, A Q; Chin, L K; Yang, Y
2011-06-07
This paper presents a tunable optofluidic prism based on the configuration of two laminar flow streams with different refractive indices in a triangular chamber. The chambers with 70° and 90° apex angles are designed based on simulation results, which provide the optimum working range and avoid recirculating flows in the chambers. In addition, a hydrodynamic model has been developed to predict the tuning of the prisms by the variation in the flow rates. Prisms with different refractive indices are realized using benzyl alcohol and deionized (DI) water as the inner liquids, respectively. The mixture of ethylene glycol and DI water with an effective refractive index matched to that of the microchannel is used as the outer liquid. The apex angle of the prism is tuned from 75° to 135° by adjusting the ratio of the two flow rates. Subsequently, the deviation angle of the output light beam is tuned from -13.5° to 22°. One of the new features of this optofluidic prism is its capability to transform from a symmetric to an asymmetric prism with the assistance of a third flow. Two optical behaviours have been performed using the optofluidic prism. First, parallel light beam scanning is achieved with a constant deviation angle of 10° and a tuning range of 60 μm using the asymmetric prism. The detected output light intensity is increased by 65.7%. Second, light dispersion is experimentally demonstrated using 488-nm and 633-nm laser beams. The two laser beams become distinguishable with a deviation angle difference of 2.5° when the apex angle of the prism reaches 116°.
Ajtony, Csilla; Elkarmouty, Ahmed; Barton, Keith; Kotecha, Aachal
2016-06-01
To evaluate the levels of agreement between the standard reusable prism and a disposable prism, and to examine the agreement between ophthalmologists, nursing and technical staff when measuring intraocular pressure (IOP) using the Goldmann applanation tonometer. Three hundred eyes of 300 patients were recruited. IOP measurements were made in a randomised order by three observer groups consisting of ophthalmologists and ophthalmic technicians/nurses taken from a pool of clinicians working within a busy outpatient clinic. Agreement was calculated by Bland-Altman analysis, showing the mean difference and 95% limits of agreement (LoA) of measurements. The mean difference between the reusable and disposable prism IOP measurements was <0.5 mm Hg. The LoA ranged from ±3.1 to ±4.9 mm Hg, depending on the observer group. The interobserver variability was <1 mm Hg across all observer groups; the LoA was slightly higher for observers using the reusable prism (range between ±4.3 and ±5.6 mm Hg) compared with using the disposable prism (range between ±3.7 and ±5.4 mm Hg) across observer groups. There is an acceptable agreement between IOP measurements made with the reusable Goldmann tonometer prism and the disposable Tonosafe prism. Interobserver variability in IOP measurements within an outpatient setting is larger than that found within a research setting, and may be of a level that impacts on clinical decision-making. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Prism adaptation does not alter configural processing of faces.
Bultitude, Janet H; Downing, Paul E; Rafal, Robert D
2013-01-01
Patients with hemispatial neglect ('neglect') following a brain lesion show difficulty responding or orienting to objects and events on the left side of space. Substantial evidence supports the use of a sensorimotor training technique called prism adaptation as a treatment for neglect. Reaching for visual targets viewed through prismatic lenses that induce a rightward shift in the visual image results in a leftward recalibration of reaching movements that is accompanied by a reduction of symptoms in patients with neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Interestingly, prism adaptation can also alter aspects of non-lateralised spatial attention. We previously demonstrated that prism adaptation alters the extent to which neglect patients and healthy participants process local features versus global configurations of visual stimuli. Since deficits in non-lateralised spatial attention are thought to contribute to the severity of neglect symptoms, it is possible that the effect of prism adaptation on these deficits contributes to its efficacy. This study examines the pervasiveness of the effects of prism adaptation on perception by examining the effect of prism adaptation on configural face processing using a composite face task. The composite face task is a persuasive demonstration of the automatic global-level processing of faces: the top and bottom halves of two familiar faces form a seemingly new, unknown face when viewed together. Participants identified the top or bottom halves of composite faces before and after prism adaptation. Sensorimotor adaptation was confirmed by significant pointing aftereffect, however there was no significant change in the extent to which the irrelevant face half interfered with processing. The results support the proposal that the therapeutic effects of prism adaptation are limited to dorsal stream processing.
Is the Aligning Prism Measured with the Mallett Unit Correlated with Fusional Vergence Reserves?
Conway, Miriam L.; Thomas, Jennifer; Subramanian, Ahalya
2012-01-01
Background The Mallett Unit is a clinical test designed to detect the fixation disparity that is most likely to occur in the presence of a decompensated heterophoria. It measures the associated phoria, which is the “aligning prism” needed to nullify the subjective disparity. The technique has gained widespread acceptance within professions such as optometry, for investigating suspected cases of decompensating heterophoria; it is, however, rarely used by orthoptists and ophthalmologists. The aim of this study was to investigate whether fusional vergence reserves, measured routinely by both orthoptists and ophthalmologists to detect heterophoria decompensation, were correlated with aligning prism (associated phoria) in a normal clinical population. Methodology/Principal Findings Aligning prism (using the Mallett Unit) and fusional vergence reserves (using a prism bar) were measured in 500 participants (mean 41.63 years; standard deviation 11.86 years) at 40 cm and 6 m. At 40 cm a strong correlation (p<0.001) between base in aligning prism (Exo FD) and positive fusional reserves was found. Of the participants with zero aligning prism 30% had reduced fusional reserves. At 6 m a weak correlation between base out aligning prism (Eso FD) and negative fusional reserves was found to break (p = 0.01) and to recovery (p = 0.048). Of the participants with zero aligning prism 12% reported reduced fusional reserves. Conclusions/Significance For near vision testing, the strong inverse correlation between base in aligning prism (Exo FD) and fusional vergence reserves supports the notion that both measures are indicators of decompensation of heterophoria. For distance vision testing and for those patients reporting zero aligning prism further research is required to determine why the relationship appears to be weak/non-existent? PMID:22905174
Code of Federal Regulations, 2013 CFR
2013-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2014 CFR
2014-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2014 CFR
2014-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2012 CFR
2012-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2012 CFR
2012-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Code of Federal Regulations, 2013 CFR
2013-01-01
... this paragraph are not required except for persons found to have more than 1 prism diopter of hyperphoria, 6 prism diopters of esophoria, or 6 prism diopters of exophoria. If any of these values are...
Design of direct-vision cyclo-olefin-polymer double Amici prism for spectral imaging.
Wang, Lei; Shao, Zhengzheng; Tang, Wusheng; Liu, Jiying; Nie, Qianwen; Jia, Hui; Dai, Suian; Zhu, Jubo; Li, Xiujian
2017-10-20
A direct-vision Amici prism is a desired dispersion element in the value of spectrometers and spectral imaging systems. In this paper, we focus on designing a direct-vision cyclo-olefin-polymer double Amici prism for spectral imaging systems. We illustrate a designed structure: E48R/N-SF4/E48R, from which we obtain 13 deg dispersion across the visible spectrum, which is equivalent to 700 line pairs/mm grating. We construct a simulative spectral imaging system with the designed direct-vision cyclo-olefin-polymer double Amici prism in optical design software and compare its imaging performance to a glass double Amici prism in the same system. The results of spot-size RMS demonstrate that the plastic prism can serve as well as their glass competitors and have better spectral resolution.
Modeling laser brightness from cross Porro prism resonators
NASA Astrophysics Data System (ADS)
Forbes, Andrew; Burger, Liesl; Litvin, Igor Anatolievich
2006-08-01
Laser brightness is a parameter often used to compare high power laser beam delivery from various sources, and incorporates both the power contained in the particular mode, as well as the propagation of that mode through the beam quality factor, M2. In this study a cross Porro prism resonator is considered; crossed Porro prism resonators have been known for some time, but until recently have not been modeled as a complete physical optics system that allows the modal output to be determined as a function of the rotation angle of the prisms. In this paper we consider the diffraction losses as a function of the prism rotation angle relative to one another, and combine this with the propagation of the specific modes to determine the laser output brightness as a function of the prism orientation.
Jones, Jeanne; Kalkan, Erol; Stephens, Christopher
2017-02-23
A continually increasing number of high-quality digital strong-motion records from stations of the National Strong-Motion Project (NSMP) of the U.S. Geological Survey (USGS), as well as data from regional seismic networks within the United States, call for automated processing of strong-motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong-motion records. When used without AQMS, PRISM provides batch-processing capabilities. The PRISM version 1.0.0 is platform independent (coded in Java), open source, and does not depend on any closed-source or proprietary software. The software consists of two major components: a record processing engine and a review tool that has a graphical user interface (GUI) to manually review, edit, and process records. To facilitate use by non-NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand-alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible in order to accommodate new processing techniques. This report provides a thorough description and examples of the record processing features supported by PRISM. All the computing features of PRISM have been thoroughly tested.
Saj, Arnaud; Cojan, Yann; Vocat, Roland; Luauté, Jacques; Vuilleumier, Patrik
2013-01-01
Unilateral spatial neglect involves a failure to report or orient to stimuli in the contralesional (left) space due to right brain damage, with severe handicap in everyday activities and poor rehabilitation outcome. Because behavioral studies suggest that prism adaptation may reduce spatial neglect, we investigated the neural mechanisms underlying prism effects on visuo-spatial processing in neglect patients. We used functional magnetic resonance imaging (fMRI) to examine the effect of (right-deviating) prisms on seven patients with left neglect, by comparing brain activity while they performed three different spatial tasks on the same visual stimuli (bisection, search, and memory), before and after a single prism-adaptation session. Following prism adaptation, fMRI data showed increased activation in bilateral parietal, frontal, and occipital cortex during bisection and visual search, but not during the memory task. These increases were associated with significant behavioral improvement in the same two tasks. Changes in neural activity and behavior were seen only after prism adaptation, but not attributable to mere task repetition. These results show for the first time the neural substrates underlying the therapeutic benefits of prism adaptation, and demonstrate that visuo-motor adaptation induced by prism exposure can restore activation in bilateral brain networks controlling spatial attention and awareness. This bilateral recruitment of fronto-parietal networks may counteract the pathological biases produced by unilateral right hemisphere damage, consistent with recent proposals that neglect may reflect lateralized deficits induced by bilateral hemispheric dysfunction. Copyright © 2011 Elsevier Ltd. All rights reserved.
Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
Shi, Tujin; Sun, Xuefei; Gao, Yuqian; Fillmore, Thomas L.; Schepmoes, Athena A.; Zhao, Rui; He, Jintang; Moore, Ronald J.; Kagan, Jacob; Rodland, Karin D.; Liu, Tao; Liu, Alvin Y.; Smith, Richard D.; Tang, Keqi; Camp, David G.; Qian, Wei-Jun
2013-01-01
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50–100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion. Limits of quantification (LOQ) at low ng/mL levels with a median coefficient of variation (CV) of ~12% were achieved for proteins spiked into human female serum. PRISM-SRM provided >100-fold improvement in the LOQ when compared to conventional LC-SRM measurements. PRISM-SRM was then applied to measure several low-abundance endogenous serum proteins, including prostate-specific antigen (PSA), in clinical prostate cancer patient sera. PRISM-SRM enabled confident detection of all target endogenous serum proteins except the low pg/mL-level cardiac troponin T. A correlation coefficient >0.99 was observed for PSA between the results from PRISM-SRM and immunoassays. Our results demonstrate that PRISM-SRM can successful quantify low ng/mL proteins in human plasma or serum without depletion. We anticipate broad applications for PRISM-SRM quantification of low-abundance proteins in candidate biomarker verification and systems biology studies. PMID:23763644
User’s Guide Engineering Data Compendium Human Perception and Performance
1988-01-01
covered (CRef. 1.222) by large wedges of sound-absorbing material to minimize Achromatic. (1) Characterized by an absence of chroma reflections and...walk model. A model of the perception and Risley prism. A prism assembly comprised of two thin decision response components in reaction time tasks... wedge prisms (generally identical) arranged in series. According to the model, an ideal detector accumulates Rotating the two prisms in opposite
Postural stability changes during large vertical diplopia induced by prism wear in normal subjects.
Matsuo, Toshihiko; Yamasaki, Hanako; Yasuhara, Hirotaka; Hasebe, Kayoko
2013-01-01
To test the effect of double vision on postural stability, we measured postural stability by electric stabilometry before prism-wearing and immediately, 15, 30, and 60min after continuous prism-wearing with 6 prism diopters in total (a 3-prism-diopter prism placed with the base up in front of one eye and with the base down in front of the other eye) in 20 normal adult individuals with their eyes open or closed. Changes in stabilometric parameters in the time course of 60min were analyzed statistically by repeated-measure analysis of variance. When subjectsセ eyes were closed, the total linear length (cm) and the unit-time length (cm/sec) of the sway path were significantly shortened during the 60-minute prism-wearing (p<0.05). No significant change was noted in any stabilometric parameters obtained with the eyes open during the time course. In conclusion, postural stability did not change with the eyes open in the condition of large vertical diplopia, induced by prism-wearing for 60min, while the stability became better when measured with the eyes closed. A postural control mechanism other than that derived from visual input might be reinforced under abnormal visual input such as non-fusionable diplopia.
Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface.
McCafferty, Sean; Lim, Garrett; Duncan, William; Enikov, Eniko; Schwiegerling, Jim
2016-09-01
We evaluate solutions for an applanating surface modification to the Goldmann tonometer prism, which substantially negates the errors due to patient variability in biomechanics. A modified Goldmann or correcting applanation tonometry surface (CATS) prism is presented which was optimized to minimize the intraocular pressure (IOP) error due to corneal thickness, stiffness, curvature, and tear film. Mathematical modeling with finite element analysis (FEA) and manometric IOP referenced cadaver eyes were used to optimize and validate the design. Mathematical modeling of the optimized CATS prism indicates an approximate 50% reduction in each of the corneal biomechanical and tear film errors. Manometric IOP referenced pressure in cadaveric eyes demonstrates substantial equivalence to GAT in nominal eyes with the CATS prism as predicted by modeling theory. A CATS modified Goldmann prism is theoretically able to significantly improve the accuracy of IOP measurement without changing Goldmann measurement technique or interpretation. Clinical validation is needed but the analysis indicates a reduction in CCT error alone to less than ±2 mm Hg using the CATS prism in 100% of a standard population compared to only 54% less than ±2 mm Hg error with the present Goldmann prism. This article presents an easily adopted novel approach and critical design parameters to improve the accuracy of a Goldmann applanating tonometer.
NASA Astrophysics Data System (ADS)
Agrawal, L.; Bhardwaj, A.; Pal, S.; Kumar, A.
2007-11-01
This article presents the results of a detailed theoretical and experimental analysis carried out on a folded Z-shaped polarization coupled, electro-optically Q-switched laser resonator with Porro prisms and waveplates. The advantages of adding waveplates in a Porro prism resonator have been explored for creating high loss condition prior to Q-switching and obtaining variable reflectivity with fixed orientation of Porro prism. Generalized expressions have been derived in terms of azimuth angles and phase shifts introduced by the polarizing elements. These expressions corroborate with known reported results under appropriate substitutions. A specific case of a crossed Porro prism diode-pumped Nd:YAG laser has been theoretically and experimentally investigated. In the feedback arm, a 0.57λ waveplate oriented at 135° completely compensates the phase shift of a fused silica Porro prism and provides better tolerances than a BK-7 prism/0.60λ waveplate combination to stop prelasing. The fused silica prism/0.57λ combination with waveplate at 112° acts like a 100% mirror and was utilized for optimization of free running performance. The effective reflectivity was determined for various orientations of the quarter waveplate in the gain arm to numerically estimate the Q-switched laser pulse parameters through rate equation analysis. Experimental results match well with the theoretical analysis.
Accuracy assessment of ALOS optical instruments: PRISM and AVNIR-2
NASA Astrophysics Data System (ADS)
Tadono, Takeo; Shimada, Masanobu; Iwata, Takanori; Takaku, Junichi; Kawamoto, Sachi
2017-11-01
This paper describes the updated results of calibration and validation to assess the accuracies for optical instruments onboard the Advanced Land Observing Satellite (ALOS, nicknamed "Daichi"), which was successfully launched on January 24th, 2006 and it is continuously operating very well. ALOS has an L-band Synthetic Aperture Radar called PALSAR and two optical instruments i.e. the Panchromatic Remotesensing Instrument for Stereo Mapping (PRISM) and the Advanced Visible and Near Infrared Radiometer type-2 (AVNIR-2). PRISM consists of three radiometers and is used to derive a digital surface model (DSM) with high spatial resolution that is an objective of the ALOS mission. Therefore, geometric calibration is important in generating a precise DSM with stereo pair images of PRISM. AVNIR-2 has four radiometric bands from blue to near infrared and uses for regional environment and disaster monitoring etc. The radiometric calibration and image quality evaluation are also important for AVNIR-2 as well as PRISM. This paper describes updated results of geometric calibration including geolocation determination accuracy evaluations of PRISM and AVNIR-2, image quality evaluation of PRISM, and validation of generated PRISM DSM. These works will be done during the ALOS mission life as an operational calibration to keep absolute accuracies of the standard products.
Influence of Visual Prism Adaptation on Auditory Space Representation.
Pochopien, Klaudia; Fahle, Manfred
2017-01-01
Prisms shifting the visual input sideways produce a mismatch between the visual versus felt position of one's hand. Prism adaptation eliminates this mismatch, realigning hand proprioception with visual input. Whether this realignment concerns exclusively the visuo-(hand)motor system or it generalizes to acoustic inputs is controversial. We here show that there is indeed a slight influence of visual adaptation on the perceived direction of acoustic sources. However, this shift in perceived auditory direction can be fully explained by a subconscious head rotation during prism exposure and by changes in arm proprioception. Hence, prism adaptation does only indirectly generalize to auditory space perception.
Prism Window for Optical Alignment
NASA Technical Reports Server (NTRS)
Tang, Hong
2008-01-01
A prism window has been devised for use, with an autocollimator, in aligning optical components that are (1) required to be oriented parallel to each other and/or at a specified angle of incidence with respect to a common optical path and (2) mounted at different positions along the common optical path. The prism window can also be used to align a single optical component at a specified angle of incidence. Prism windows could be generally useful for orienting optical components in manufacture of optical instruments. "Prism window" denotes an application-specific unit comprising two beam-splitter windows that are bonded together at an angle chosen to obtain the specified angle of incidence.
Some Experiments with Thin Prisms.
ERIC Educational Resources Information Center
Fernando, P. C. B.
1980-01-01
Described are several experiments, for a course in geometrical optics or for a college physics laboratory, which have a bearing on ophthalmic optics. Experiments include the single thin prism, crossed prisms, and the prismatic power of a lens. (Author/DS)
PRISM: Priority Symptom Management Project phase I: assessment.
Ropka, M E; Spencer-Cisek, P
2001-01-01
To provide an overview of the process, goals, and outcome recommendations from the assessment phase of the Oncology Nursing Society's Priority Symptom Management (PRISM) project and to provide the foundation for a series of evidence-based practice and qualitative systematic review articles generated from the first phase of PRISM. Published articles, abstracts, and books; computerized databases; nonpublished research; personal communications; and proceedings of the PRISM summit meeting. Symptom management is a key component in quality cancer care. The assessment phase of PRISM yielded systematic reviews with an evidence-based framework to evaluate key symptoms, developed a framework for teaching and evaluating other symptoms, and recommended future ONS initiatives. Outcome recommendations from the PRISM summit targeted practice; professional and public education; research; and health policy. These activities provide background for subsequent evidence-based practice and qualitative systematic review articles that will focus on cancer symptom management.
Limited Plasticity of Prismatic Visuomotor Adaptation
Wischhusen, Sven; Fahle, Manfred
2017-01-01
Movements toward an object displaced optically through prisms adapt quickly, a striking example for the plasticity of neuronal visuomotor programs. We investigated the degree and time course of this system’s plasticity. Participants performed goal-directed throwing or pointing movements with terminal feedback before, during, and after wearing prism goggles shifting the visual world laterally either to the right or to the left. Prism adaptation was incomplete even after 240 throwing movements, still deviating significantly laterally by on average of 0.8° (CI = 0.20°) at the end of the adaptation period. The remaining lateral deviation was significant for pointing movements only with left shifting prisms. In both tasks, removal of the prisms led to an aftereffect which disappeared in the course of further training. This incomplete prism adaptation may be caused by movement variability combined with an adaptive neuronal control system exhibiting a finite capacity for evaluating movement errors. PMID:28473909
Brooks, C W; Riley, H D
1994-06-01
Success in fitting progressive addition lenses is dependent upon the accurate placement of the progressive zone. Both eyes must track simultaneously within the boundary of the progressive corridor. Vertical prism will displace the wearer's lines of sight and consequently eye position. Because fitting heights are measured using an empty frame, subjects with vertical phorias usually will fuse, and not show the vertical differences in pupil heights during the measuring process. Therefore, when prescriptions contain vertical prism one must consider the changes in measured fitting heights that will occur once the lenses are placed in the frame. Fitting heights must be altered approximately 0.3 mm for each vertical prism diopter prescribed. The fitting height adjustment is opposite from the base direction of the prescribed prism. An explanation of the effect of prescribed horizontal prism on monocular interpupillary distance (PD) measurements is also included.
Salt-induced square prism Pd microtubes and their ethanol electrocatalysis properties
NASA Astrophysics Data System (ADS)
Jiang, Kunpeng; Ma, Shenghua; Wang, Yinan; Zhang, Ying; Han, Xiaojun
2017-05-01
The synthesis of square prism tubes are always challenging due to their thermo and dynamical instability. We demonstrated a simple method using Pd2+ doped PoPD oligomers as building blocks to assemble into 1D square prism metal-organic microtubes, which consists of cataphracted nanosheets on the surfaces. After high temperature treatment, the microtubes became square prism Pd tubes with a cross section size of 3 μm. The pure Pd microtubes showed excellent catalyzing activity towards the electro oxidation of ethanol. Their electrochemically active surface area is 48.2 m2 g-1, which indicates the square prism Pd tubes have great potential in the field of fuel cell.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weirs, V. Gregory
2012-03-01
Prism is a ParaView plugin that simultaneously displays simulation data and material model data. This document describes its capabilities and how to use them. A demonstration of Prism is given in the first section. The second section contains more detailed notes on less obvious behavior. The third and fourth sections are specifically for Alegra and CTH users. They tell how to generate the simulation data and SESAME files and how to handle aspects of Prism use particular to each of these codes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Fei, E-mail: long.drf@gmail.com; Chi, Shangsen; Institute of Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083
Wurtzite Cu{sub 2}ZnSnS{sub 4} (CZTS) hexagonal prisms were synthesized by a simple ultrasound-microwave solvothermal method. The product was characterized by XRD, FESEM, EDS, TEM, Raman and UV–vis spectrometer. The hexagonal prisms were 0.5–2 μm wide and 5–12 μm long. The PVP played an important role in the formation of the CZTS hexagonal prisms. In addition, the ultrasound-assisted microwave process was helpful for synthesis of wurtzite rather than kesterite phase CZTS. A nucleation–dissolution–recrystallization mechanism was also proposed to explain the growth of the CZTS hexagonal prisms. - Graphical abstract: Wurtzite Cu{sub 2}ZnSnS{sub 4} hexagonal prisms were synthesized by ultrasound-microwave solvothermal method.more » The ultrasound-assisted microwave process and PVP were useful to the growth of CZTS. A nucleation–dissolution–recrystallization growth mechanism was also proposed. - Highlights: • Wurtzite Cu{sub 2}ZnSnS{sub 4} was prepared by ultrasound-assisted microwave solvothermal method. • The wurtzite CZTS hexagonal prisms are demonstrated a band gap of 1.49 eV. • Synergistic effect of ultrasound and microwave is helpful to prepare Wurtzite CZTS. • PVP plays an important role in the formation of the CZTS hexagonal prisms. • Nucleation–dissolution–recrystallization growth mechanism of the CZTS was proposed.« less
Thio, Si Kuan; Jiang, Dongyue; Park, Sung-Yong
2018-06-12
Optofluidics is an emerging research field that combines the two disciplines of microfluidics and optics. By using microfluidic technologies for light control, optofluidic devices can offer several advantages over solid-type optical components, including optical-grade smoothness at the fluidic interface and a high degree of optical tunability without bulky and complex mechanical moving parts. These features have made optofluidic devices more versatile and reconfigurable to improve their optical performances. In this paper, we present a novel optofluidic sunlight manipulation technology for solar indoor lighting using the electrowetting principle. Rooftop sunlight is collected by a solar concentrator and guided to individual rooms along an optical fiber (waveguide) on the bottom of which tunable liquid prisms are linearly integrated. In the light-off mode, electrowetting controls the apex angle of the prisms to be φ = 0°. Under this condition, incoming sunlight experiences total internal reflection and thus keeps propagating along the optical fiber without leaking to the prism bottom for indoor lighting. In contrast, when liquid prisms are controlled to have the angle at φ > 0°, incoming sunlight is partially transmitted to the bottom surface of the arrayed prisms to contribute to interior illumination. Simulation studies validate that our electrowetting-driven solar indoor lighting (e-SIL) system is capable of variably tuning the lighting power from 0% to 98.6% of the input solar power by controlling the prism angle and varying the refractive index of prism materials. For experimental studies, we fabricated an array of 5 prisms filled with silicone oil and water. Using a fiber illuminator as a white light source that includes visible light with various incident angles, we have demonstrated two important lighting functions, (1) light on/off and (2) illumination power control. Lighting performance can be further enhanced by lowering the aspect ratio of the prism as well as increasing the number of prisms. The e-SIL technology based on tunable liquid prisms offers a new approach towards sustainable buildings that are able to reduce their electricity usage as well as provide a healthy and comfortable indoor environment under illumination of natural sunlight.
49 CFR 390.203 - PRISM State registration/biennial updates.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the Performance and Registration Information Systems Management (PRISM) program (authorized under... FEDERAL MOTOR CARRIER SAFETY REGULATIONS; GENERAL Unified Registration System § 390.203 PRISM State... procedures, provided the State has integrated the USDOT registration/update capability into its vehicle...
49 CFR 390.203 - PRISM State registration/biennial updates.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the Performance and Registration Information Systems Management (PRISM) program (authorized under... FEDERAL MOTOR CARRIER SAFETY REGULATIONS; GENERAL Unified Registration System § 390.203 PRISM State... procedures, provided the State has integrated the USDOT registration/update capability into its vehicle...
Sarri, Margarita; Greenwood, Richard; Kalra, Lalit; Driver, Jon
2011-01-01
Previous research has shown that prism adaptation (prism adaptation) can ameliorate several symptoms of spatial neglect after right-hemisphere damage. But the mechanisms behind this remain unclear. Recently we reported that prisms may increase leftward awareness for neglect in a task using chimeric visual objects, despite apparently not affecting awareness in a task using chimeric emotional faces (Sarri et al., 2006). Here we explored potential reasons for this apparent discrepancy in outcome, by testing further whether the lack of a prism effect on the chimeric face task task could be explained by: i) the specific category of stimuli used (faces as opposed to objects); ii) the affective nature of the stimuli; and/or iii) the particular task implemented, with the chimeric face task requiring forced-choice judgements of lateral ‘preference’ between pairs of identical, but left/right mirror-reversed chimeric face tasks (as opposed to identification for the chimeric object task). We replicated our previous pattern of no impact of prisms on the emotional chimeric face task here in a new series of patients, while also similarly finding no beneficial impact on another lateral ‘preference’ measure that used non-face non-emotional stimuli, namely greyscale gradients. By contrast, we found the usual beneficial impact of prism adaptation (prism adaptation) on some conventional measures of neglect, and improvements for at least some patients in a different face task, requiring explicit discrimination of the chimeric or non-chimeric nature of face stimuli. The new findings indicate that prism therapy does not alter spatial biases in neglect as revealed by ‘lateral preference tasks’ that have no right or wrong answer (requiring forced-choice judgements on left/right mirror-reversed stimuli), regardless of whether these employ face or non-face stimuli. But our data also show that prism therapy can beneficially modulate some aspects of visual awareness in spatial neglect not only for objects, but also for face stimuli, in some cases. PMID:20171612
The PRISM3D paleoenvironmental reconstruction
Dowsett, H.; Robinson, M.; Haywood, A.M.; Salzmann, U.; Hill, Daniel; Sohl, L.E.; Chandler, M.; Williams, Mark; Foley, K.; Stoll, D.K.
2010-01-01
The Pliocene Research, Interpretation and Synoptic Mapping (PRISM) paleoenvironmental reconstruction is an internally consistent and comprehensive global synthesis of a past interval of relatively warm and stable climate. It is regularly used in model studies that aim to better understand Pliocene climate, to improve model performance in future climate scenarios, and to distinguish model-dependent climate effects. The PRISM reconstruction is constantly evolving in order to incorporate additional geographic sites and environmental parameters, and is continuously refined by independent research findings. The new PRISM three dimensional (3D) reconstruction differs from previous PRISM reconstructions in that it includes a subsurface ocean temperature reconstruction, integrates geochemical sea surface temperature proxies to supplement the faunal-based temperature estimates, and uses numerical models for the first time to augment fossil data. Here we describe the components of PRISM3D and describe new findings specific to the new reconstruction. Highlights of the new PRISM3D reconstruction include removal of Hudson Bay and the Great Lakes and creation of open waterways in locations where the current bedrock elevation is less than 25m above modern sea level, due to the removal of the West Antarctic Ice Sheet and the reduction of the East Antarctic Ice Sheet. The mid-Piacenzian oceans were characterized by a reduced east-west temperature gradient in the equatorial Pacific, but PRISM3D data do not imply permanent El Niño conditions. The reduced equator-to-pole temperature gradient that characterized previous PRISM reconstructions is supported by significant displacement of vegetation belts toward the poles, is extended into the Arctic Ocean, and is confirmed by multiple proxies in PRISM3D. Arctic warmth coupled with increased dryness suggests the formation of warm and salty paleo North Atlantic Deep Water (NADW) and a more vigorous thermohaline circulation system that may have provided the enhanced ocean heat transport necessary to move warm surface water to the Arctic. New deep ocean temperature data also suggests greater warmth and further southward penetration of paleo NADW.
Christophe, Laure; Chabanat, Eric; Delporte, Ludovic; Revol, Patrice; Volckmann, Pierre; Jacquin-Courtois, Sophie; Rossetti, Yves
Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations.
SU-G-IeP1-13: Sub-Nyquist Dynamic MRI Via Prior Rank, Intensity and Sparsity Model (PRISM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, B; Gao, H
Purpose: Accelerated dynamic MRI is important for MRI guided radiotherapy. Inspired by compressive sensing (CS), sub-Nyquist dynamic MRI has been an active research area, i.e., sparse sampling in k-t space for accelerated dynamic MRI. This work is to investigate sub-Nyquist dynamic MRI via a previously developed CS model, namely Prior Rank, Intensity and Sparsity Model (PRISM). Methods: The proposed method utilizes PRISM with rank minimization and incoherent sampling patterns for sub-Nyquist reconstruction. In PRISM, the low-rank background image, which is automatically calculated by rank minimization, is excluded from the L1 minimization step of the CS reconstruction to further sparsify themore » residual image, thus allowing for higher acceleration rates. Furthermore, the sampling pattern in k-t space is made more incoherent by sampling a different set of k-space points at different temporal frames. Results: Reconstruction results from L1-sparsity method and PRISM method with 30% undersampled data and 15% undersampled data are compared to demonstrate the power of PRISM for dynamic MRI. Conclusion: A sub- Nyquist MRI reconstruction method based on PRISM is developed with improved image quality from the L1-sparsity method.« less
3D Printed Prisms with Tunable Dispersion for the THz Frequency Range
NASA Astrophysics Data System (ADS)
Busch, Stefan F.; Castro-Camus, Enrique; Beltran-Mejia, Felipe; Balzer, Jan C.; Koch, Martin
2018-04-01
Here, we present a 3D printed prism for THz waves made out of an artificial dielectric material in which the dispersion can be tuned by external compression. The artificial material consists of thin dielectric layers with variable air spacings which has been produced using a fused deposition molding process. The material properties are carefully characterized and the functionality of the prisms is in a good agreement with the underlying theory. These prisms are durable, lightweight, inexpensive, and easy to produce.
3D Printed Prisms with Tunable Dispersion for the THz Frequency Range
NASA Astrophysics Data System (ADS)
Busch, Stefan F.; Castro-Camus, Enrique; Beltran-Mejia, Felipe; Balzer, Jan C.; Koch, Martin
2018-06-01
Here, we present a 3D printed prism for THz waves made out of an artificial dielectric material in which the dispersion can be tuned by external compression. The artificial material consists of thin dielectric layers with variable air spacings which has been produced using a fused deposition molding process. The material properties are carefully characterized and the functionality of the prisms is in a good agreement with the underlying theory. These prisms are durable, lightweight, inexpensive, and easy to produce.
Optical power splitter for splitting high power light
English, Jr., Ronald E.; Christensen, John J.
1995-01-01
An optical power splitter for the distribution of high-power light energy has a plurality of prisms arranged about a central axis to form a central channel. The input faces of the prisms are in a common plane which is substantially perpendicular to the central axis. A beam of light which is substantially coaxial to the central axis is incident on the prisms and at least partially strikes a surface area of each prism input face. The incident beam also partially passes through the central channel.
Retroreflective Phase Retardation Prisms.
1981-06-01
resonant cavity of a 1.064 Mm laser. This report shows that it is possible to coat the reflecting surfaces of a porro prism so that incident plane...with controlled phase retardation can be made by coating each reflecting surface of a porro prism with a single dielectric film. The amount of phase...of angle of incidence (n, < n2) S. Phase change on reflection as a function of angle of incidence (n" n ) [RL-0202-’R 6. Porro prism 7. Phase change
[Integration design and diffraction characteristics analysis of prism-grating-prism].
He, Tian-Bo; Bayanheshig; Li, Wen-Hao; Kong, Peng; Tang, Yu-Guo
2014-01-01
Prism-grating-prism (PGP) module is the important dispersing component in the hyper spectral imager. In order to effectively predict the distribution of diffraction efficiency of the whole PGP component and its diffraction characteristics before fabrication, a method of the PGP integration design is proposed. From the point of view of the volume phase holographic grating (VPHG) design, combined with the restrictive correlation between the various parameters of prisms and grating, we compiled the analysis software for calculating the whole PGP's diffraction efficiency. Furthermore, the effects of the structure parameters of prisms and grating on the PGP's diffraction characteristics were researched in detail. In particular we discussed the Bragg wavelength shift behaviour of the grating and a broadband PGP spectral component with high diffraction efficiency was designed for the imaging spectrometers. The result of simulation indicated that the spectral bandwidth of the PGP becomes narrower with the dispersion coefficient of prism 1 material decreasing; Bragg wavelength shift characteristics broaden the bandwidth of VPHG both spectrally and angularly, higher angular selectivity is desirable for selection requirements of the prism 1 material, and it can be easily tuned to achieve spectral bandwidth suitable for imaging PGP spectrograph; the vertex angle of prism 1, the film thickness and relative permittivity modulation of the grating have a significant impact on the distribution of PGP's diffraction efficiency, so precision control is necessary when fabrication. The diffraction efficiency of the whole PGP component designed by this method is no less than 50% in the wavelength range from 400 to 1000 nm, the specific design parameters have been given in this paper that have a certain reference value for PGP fabrication.
Peter, Nicole; Kleinjung, Tobias; Horat, Lukas; Schmidt-Weitmann, Sabine; Meyer, Martin; Büchi, Stefan; Weidt, Steffi
2016-03-22
Chronic subjective tinnitus is a frequent condition that affects the subject's quality of life. The lack of objective measures of tinnitus necessitates the use of self-reporting and often time-consuming questionnaires for evaluating tinnitus severity. The Pictorial Representation of Illness and Self Measure (PRISM) is a two dimensional pictorial method to assess the burden of suffering. Patients illustrate their burden of suffering by the distance from a "self" to an illness circle, whereby a shorter distance indicates a higher burden of suffering. The aim of this prospective observational study was to validate the burden of suffering measured with PRISM in tinnitus patients by comparing it with different standardized questionnaires currently used in tinnitus evaluation. A total of 188 patients filled out an online-based survey including sociodemographic variables and the following questionnaires: Tinnitus Handicap Inventory (THI), Tinnitus Questionnaire (TQ), WHO Quality of Life-Questionnaire (WHOQOL-BREF), and the Beck Depression Inventory (BDI). The subtle differences in the burden of suffering were accessed by using PRISM as an iPad version. Based on PRISM performance patients could easily be assigned in three groups, these being mildly, moderately, or severely affected akin to the standard questionnaires. The burden of suffering measured with PRISM correlated with the tinnitus severity (THI and TQ), depressive symptoms (BDI), and health related quality of life (WHOQOL-BREF) (all p ≤ 0.001). In the three PRISM groups tinnitus severity (THI and TQ), and depressive symptoms (BDI) differed significantly (all p ≤ 0.01). PRISM is an easily understood and time saving method for the assessment of burden of suffering in tinnitus patients. In daily clinical practice PRISM can help to identify patients with decompensated tinnitus that require more intensive treatment.
Accurate geometrical optics model for single-lens stereovision system using a prism.
Cui, Xiaoyu; Lim, Kah Bin; Guo, Qiyong; Wang, DaoLei
2012-09-01
In this paper, we proposed a new method for analyzing the image formation of a prism. The prism was considered as a single optical system composed of some planes. By analyzing each plane individually and then combining them together, we derived a transformation matrix which can express the relationship between an object point and its image by the refraction of a prism. We also explained how to use this matrix for epipolar geometry and three-dimensional point reconstruction. Our method is based on optical geometry and could be used in a multiocular prism. Experimentation results are presented to prove the accuracy of our method is better than former researchers' and is comparable with that of the multicamera stereovision system.
Cavity Enhanced Absorption Spectroscopy Using a Broadband Prism Cavity and a Supercontinuum Source
NASA Astrophysics Data System (ADS)
Johnston, Paul S.; Lehmann, Kevin K.
2009-06-01
The multiplex advantage of current cavity enhanced spectrometers is limited by the high reflectivity bandwidth of the mirrors used to construct the high finesse cavity. Previously, we reported the design and construction of a new spectrometer that circumvents this limitation by utilizing Brewster^{,}s angle prism retroreflectors. The prisms, made from fused silica and combined with a supercontinuum source generated by pumping a highly nonlinear photonic crystal fiber, yields a spectral window ranging from 500 nm to 1750 nm. Recent progress in the instruments development will be discussed, including work on modeling the prism cavity losses, alternative prism material for use in the UV and mid-IR spectral regions, and a new high power supercontinuum source based on mode-locked picosecond laser.
Does prism width from the shell prismatic layer have a random distribution?
NASA Astrophysics Data System (ADS)
Vancolen, Séverine; Verrecchia, Eric
2008-10-01
A study of the distribution of the prism width inside the prismatic layer of Unio tumidus (Philipsson 1788, Diss Hist-Nat, Berling, Lundæ) from Lake Neuchâtel, Switzerland, has been conducted in order to determine whether or not this distribution is random. Measurements of 954 to 1,343 prism widths (depending on shell sample) have been made using a scanning electron microscope in backscattered electron mode. A white noise test has been applied to the distribution of prism sizes (i.e. width). It shows that there is no temporal cycle that could potentially influence their formation and growth. These results suggest that prism widths are randomly distributed, and related neither to external rings nor to environmental constraints.
Negative index effects from a homogeneous positive index prism
NASA Astrophysics Data System (ADS)
Marcus, Sherman W.; Epstein, Ariel
2017-12-01
Cellular structured negative index metamaterials in the form of a right triangular prism have often been tested by observing the refraction of a beam across the prism hypotenuse which is serrated in order to conform to the cell walls. We show that not only can this negative index effect be obtained from a homogeneous dielectric prism having a positive index of refraction, but in addition, for sampling at the walls of the cellular structure, the phase in the material has the illusory appearance of moving in a negative direction. Although many previous reports relied on refraction direction and phase velocity of prism structures to verify negative index design, our investigation indicates that to unambiguously demonstrate material negativity additional empirical evidence is required.
Phase-Scrambler Plate Spreads Point Image
NASA Technical Reports Server (NTRS)
Edwards, Oliver J.; Arild, Tor
1992-01-01
Array of small prisms retrofit to imaging lens. Phase-scrambler plate essentially planar array of small prisms partitioning aperture of lens into many subapertures, and prism at each subaperture designed to divert relatively large diffraction spot formed by that subaperture to different, specific point on focal plane.
Finite element analysis and experiment on high pressure apparatus with split cylinder
NASA Astrophysics Data System (ADS)
Zhao, Liang; Li, Mingzhe; Yang, Yunfei; Wang, Bolong; Li, Yi
2017-07-01
Ultra-high pressure belt-type die was designed with a large sample volume prism cavity and a split cylinder which was divided into eight segments to eliminate circumferential stress. The cylinder of this type die has no cambered surface on inner wall, and the inner hole is a hexagonal prism-type cavity. The divided bodies squeeze with each other, providing the massive support and lateral support effect of the cylinder. Simulation results indicate that the split cylinder with the prism cavity possesses much smaller stress and more uniform stress distribution. The split cylinder with the prism cavity has been shown to bear larger compressive stresses in radial, circumferential and axial directions due to its structure, and tungsten carbide is most effective in pure compression so this type cylinder could bear higher pressure. Experimental results prove that the high pressure apparatus with a prism-type cavity could bear higher pressure. The apparatus with a prism cavity could bear 52.2% more pressure than the belt-type die.
DSM Generation from ALSO/PRISM Images Using SAT-PP
NASA Astrophysics Data System (ADS)
Wolff, Kirsten; Gruen, Armin
2008-11-01
One of the most important products of ALOS/PRISM image data are accurate DSMs. To exploit the full potential of the full resolution of PRISM for DSM generation, a highly developed image matcher is needed. As a member of the validation and calibration team for PRISM we published earlier results of DSM generation using PRISM image triplets in combination with our software package SAT-PP. The overall accuracy across all object and image features for all tests lies between 1-5 pixels in matching, depending primarily on surface roughness, vegetation, image texture and image quality. Here we will discuss some new results. We focus on four different topics: the use of two different evaluation methods, the difference between a 5m and a 10m GSD for the final PRISM DSM, the influence of the level of initial information and the comparison of the quality of different combinations of the three different views forward, nadir and backward. All tests have been conducted with our testfield Bern/Thun, Switzerland.
Jensen, Garrett; Tang, Chad; Hess, Kenneth R; Bishop, Andrew J; Pan, Hubert Y; Li, Jing; Yang, James N; Tannir, Nizar M; Amini, Behrang; Tatsui, Claudio; Rhines, Laurence; Brown, Paul D; Ghia, Amol J
2017-01-01
We sought to validate the Prognostic Index for Spinal Metastases (PRISM), a scoring system that stratifies patients into subgroups by overall survival.Methods and materials: The PRISM was previously created from multivariate Cox regression with patients enrolled in prospective single institution trials of stereotactic spine radiosurgery (SSRS) for spinal metastasis. We assess model calibration and discrimination within a validation cohort of patients treated off-trial with SSRS for metastatic disease at the same institution. The training and validation cohorts consisted of 205 and 249 patients respectively. Similar survival trends were shown in the 4 PRISM. Survival was significantly different between PRISM subgroups (P<0.0001). C-index for the validation cohort was 0.68 after stratification into subgroups. We internally validated the PRISM with patients treated off-protocol, demonstrating that it can distinguish subgroups by survival, which will be useful for individualizing treatment of spinal metastases and stratifying patients for clinical trials.
Marinello, Elena; Linder, Dennis; Spoto, Andrea; Palmer, Katie; Rohrer, Peter Michael; Büchi, Stefan; Trapp, Michael; Trapp, Eva-Maria; Hoerlesberger, Nina; Piaserico, Stefano; Peserico, Andrea; Gatta, Michela; Belloni Fortina, Anna
2016-01-01
There is a need to improve the quality of communication between clinicians and parents of young patients with atopic eczema (AE). To create a tool to measure the suffering that caregivers experience in association with their child's AE (Caregiver Pictorial Representation of Illness and Self-Measure, Caregiver-PRISM), assess the validity and reliability, and identify factors associated with caregiver suffering. Caregiver-PRISM was administered to 45 parents of patients from an AE outpatient service (Padua, Italy). Caregiver-PRISM had a good test-retest reliability (r = 0.85; t7 = 4.13; p < 0.05), content validity and construct validity when used in parents of AE children. Parents with a less positive family affective climate, higher education, or with children following a diet experienced higher suffering associated with their child's AE, demonstrated by lower Caregiver-PRISM scores (p < 0.05). Our results support the use of Caregiver-PRISM in parents of AE patients to assess suffering associated with patients' illness. © 2016 S. Karger AG, Basel.
Kokaly, Raymond F.
2011-01-01
This report describes procedures for installing and using the U.S. Geological Survey Processing Routines in IDL for Spectroscopic Measurements (PRISM) software. PRISM provides a framework to conduct spectroscopic analysis of measurements made using laboratory, field, airborne, and space-based spectrometers. Using PRISM functions, the user can compare the spectra of materials of unknown composition with reference spectra of known materials. This spectroscopic analysis allows the composition of the material to be identified and characterized. Among its other functions, PRISM contains routines for the storage of spectra in database files, import/export of ENVI spectral libraries, importation of field spectra, correction of spectra to absolute reflectance, arithmetic operations on spectra, interactive continuum removal and comparison of spectral features, correction of imaging spectrometer data to ground-calibrated reflectance, and identification and mapping of materials using spectral feature-based analysis of reflectance data. This report provides step-by-step instructions for installing the PRISM software and running its functions.
Porro prism lasers: a new perspective
NASA Astrophysics Data System (ADS)
Burger, Liesl; Forbes, Andrew
2008-08-01
Porro prism lasers are insensitive to misalignment caused by, for example, shock and temperature variation, making them useful in field applications, for example in target designation and range-finding systems. This property is a result of the property of Porro prisms that they return a reflected beam parallel to the incident beam, regardless of any tilt on the prism. These lasers are generally used in a marginally stable or unstable configuration for low divergence, but in the stable configuration some interesting kaleidoscope modes can be modelled. In previous work on Porro prism resonators we formulated an analytical method of determining which Porro angles resonate and result in petal output modes, as well as the corresponding number of petals. This work has been verified using a numerical model as well as experimentally. We have developed this work further and have investigated the losses associated with a range of Porro angles as well as the effects of these losses on the resulting modes. We conclude by summarizing the design considerations for Porro prism lasers.
ePRISM: A case study in multiple proxy and mixed temporal resolution integration
Robinson, Marci M.; Dowsett, Harry J.
2010-01-01
As part of the Pliocene Research, Interpretation and Synoptic Mapping (PRISM) Project, we present the ePRISM experiment designed I) to provide climate modelers with a reconstruction of an early Pliocene warm period that was warmer than the PRISM interval (similar to 3.3 to 3.0 Ma), yet still similar in many ways to modern conditions and 2) to provide an example of how best to integrate multiple-proxy sea surface temperature (SST) data from time series with varying degrees of temporal resolution and age control as we begin to build the next generation of PRISM, the PRISM4 reconstruction, spanning a constricted time interval. While it is possible to tie individual SST estimates to a single light (warm) oxygen isotope event, we find that the warm peak average of SST estimates over a narrowed time interval is preferential for paleoclimate reconstruction as it allows for the inclusion of more records of multiple paleotemperature proxies.
Prism-based single-camera system for stereo display
NASA Astrophysics Data System (ADS)
Zhao, Yue; Cui, Xiaoyu; Wang, Zhiguo; Chen, Hongsheng; Fan, Heyu; Wu, Teresa
2016-06-01
This paper combines the prism and single camera and puts forward a method of stereo imaging with low cost. First of all, according to the principle of geometrical optics, we can deduce the relationship between the prism single-camera system and dual-camera system, and according to the principle of binocular vision we can deduce the relationship between binoculars and dual camera. Thus we can establish the relationship between the prism single-camera system and binoculars and get the positional relation of prism, camera, and object with the best effect of stereo display. Finally, using the active shutter stereo glasses of NVIDIA Company, we can realize the three-dimensional (3-D) display of the object. The experimental results show that the proposed approach can make use of the prism single-camera system to simulate the various observation manners of eyes. The stereo imaging system, which is designed by the method proposed by this paper, can restore the 3-D shape of the object being photographed factually.
Compact Packaging of Photonic Millimeter-Wave Receiver
NASA Technical Reports Server (NTRS)
Nguyen, Hung; Pouch, John; Miranda, Felix; Levi, Anthony F.
2007-01-01
A carrier structure made from a single silicon substrate is the basis of a compact, lightweight, relatively inexpensive package that holds the main optical/electronic coupling components of a photonic millimeter-wave receiver based on a lithium niobate resonator disk. The design of the package is simple and provides for precise relative placement of optical components, eliminating the need for complex, bulky positioning mechanisms like those commonly used to align optical components to optimize focus and coupling. Although a prototype of the package was fabricated as a discrete unit, the design is amenable to integration of the package into a larger photonic and/or electronic receiver system. The components (see figure) include a lithium niobate optical resonator disk of 5-mm diameter and .200- m thickness, positioned adjacent to a millimeter- wave resonator electrode. Other components include input and output coupling prisms and input and output optical fibers tipped with ball lenses for focusing and collimation, respectively. Laser light is introduced via the input optical fiber and focused into the input coupling prism. The input coupling prism is positioned near (but not in contact with) the resonator disk so that by means of evanescent-wave coupling, the input laser light in the prism gives rise to laser light propagating circumferentially in guided modes in the resonator disk. Similarly, a portion of the circumferentially propagating optical power is extracted from the disk by evanescent-wave coupling from the disk to the output coupling prism, from whence the light passes through the collimating ball lens into the output optical fiber. The lens-tipped optical fibers must be positioned at a specified focal distance from the prisms. The optical fibers and the prisms must be correctly positioned relative to the resonator disk and must be oriented to obtain the angle of incidence (55 in the prototype) required for evanescent-wave coupling of light into and out of the desired guided modes in the resonator disk. To satisfy all these requirements, precise alignment features are formed in the silicon substrate by use of a conventional wet-etching process. These features include a 5-mm-diameter, 50- m-deep cavity that holds the disk; two trapezoidal-cross-section recesses for the prisms; and two grooves that hold the optical fibers at the correct positions and angles relative to the prisms and disk. The fiber grooves contain abrupt tapers, near the prisms, that serve as hard stops for positioning the lenses at the focal distance from the prisms. There are also two grooves for prismadjusting rods. The design provides a little slack in the prism recesses for adjusting the positions of the prisms by means of these rods to optimize the optical coupling.
Analytic Expressions for the Gravity Gradient Tensor of 3D Prisms with Depth-Dependent Density
NASA Astrophysics Data System (ADS)
Jiang, Li; Liu, Jie; Zhang, Jianzhong; Feng, Zhibing
2017-12-01
Variable-density sources have been paid more attention in gravity modeling. We conduct the computation of gravity gradient tensor of given mass sources with variable density in this paper. 3D rectangular prisms, as simple building blocks, can be used to approximate well 3D irregular-shaped sources. A polynomial function of depth can represent flexibly the complicated density variations in each prism. Hence, we derive the analytic expressions in closed form for computing all components of the gravity gradient tensor due to a 3D right rectangular prism with an arbitrary-order polynomial density function of depth. The singularity of the expressions is analyzed. The singular points distribute at the corners of the prism or on some of the lines through the edges of the prism in the lower semi-space containing the prism. The expressions are validated, and their numerical stability is also evaluated through numerical tests. The numerical examples with variable-density prism and basin models show that the expressions within their range of numerical stability are superior in computational accuracy and efficiency to the common solution that sums up the effects of a collection of uniform subprisms, and provide an effective method for computing gravity gradient tensor of 3D irregular-shaped sources with complicated density variation. In addition, the tensor computed with variable density is different in magnitude from that with constant density. It demonstrates the importance of the gravity gradient tensor modeling with variable density.
Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).
Gao, Hao; Yu, Hengyong; Osher, Stanley; Wang, Ge
2011-11-01
We propose a compressive sensing approach for multi-energy computed tomography (CT), namely the prior rank, intensity and sparsity model (PRISM). To further compress the multi-energy image for allowing the reconstruction with fewer CT data and less radiation dose, the PRISM models a multi-energy image as the superposition of a low-rank matrix and a sparse matrix (with row dimension in space and column dimension in energy), where the low-rank matrix corresponds to the stationary background over energy that has a low matrix rank, and the sparse matrix represents the rest of distinct spectral features that are often sparse. Distinct from previous methods, the PRISM utilizes the generalized rank, e.g., the matrix rank of tight-frame transform of a multi-energy image, which offers a way to characterize the multi-level and multi-filtered image coherence across the energy spectrum. Besides, the energy-dependent intensity information can be incorporated into the PRISM in terms of the spectral curves for base materials, with which the restoration of the multi-energy image becomes the reconstruction of the energy-independent material composition matrix. In other words, the PRISM utilizes prior knowledge on the generalized rank and sparsity of a multi-energy image, and intensity/spectral characteristics of base materials. Furthermore, we develop an accurate and fast split Bregman method for the PRISM and demonstrate the superior performance of the PRISM relative to several competing methods in simulations.
Byatt, Nancy; Moore Simas, Tiffany A; Biebel, Kathleen; Sankaran, Padma; Pbert, Lori; Weinreb, Linda; Ziedonis, Douglas; Allison, Jeroan
2017-10-10
This pilot study was designed to inform a larger effectiveness trial by: (1) assessing the feasibility of the PRogram In Support of Moms (PRISM) and our study procedures; and, (2) determining the extent to which PRISM as compared to an active comparison group, the Massachusetts Child Access Psychiatry Program (MCPAP) for Moms alone, improves depression among perinatal women. Four practices were randomized to either PRISM or MCPAP for Moms alone, a state-wide telephonic perinatal psychiatry program. PRISM includes MCPAP for Moms plus implementation assistance with local champions, training, and implementation of office prompts and procedures to enhance depression screening, assessment and treatment. Patients with Edinburgh Postnatal Depression Scales (EPDS) ≥ 10 were recruited during pregnancy, and completed the EPDS and a structured interview at baseline and 3-12 weeks' postpartum. Among MCPAP for Moms alone practices, patients' (n = 9) EPDS scores improved from 15.22 to 10.11 (p = 0.010), whereas in PRISM practices patients' (n = 21) EPDS scores improved from 13.57 to 6.19 (p = 0.001); the between groups difference-of-differences was 2.27 (p = 0.341). PRISM was beneficial for patients, clinicians, and support staff. Both PRISM and MCPAP for Moms alone improve depression symptom severity and the percentage of women with an EPDS >10. The improvement difference between groups was not statistically significant due to limited power associated with small sample size.
Czaja, Sara J; Boot, Walter R; Charness, Neil; Rogers, Wendy A; Sharit, Joseph
2018-05-08
Information and communication technology holds promise in terms of providing support and reducing isolation among older adults. We evaluated the impact of a specially designed computer system for older adults, the Personal Reminder Information and Social Management (PRISM) system. The trial was a multisite randomized field trial conducted at 3 sites. PRISM was compared to a Binder condition wherein participants received a notebook that contained paper content similar to that contained in PRISM. The sample included 300 older adults at risk for social isolation who lived independently in the community (Mage = 76.15 years). Primary outcome measures included indices of social isolation, social support, loneliness, and well-being. Secondary outcome measures included indices of computer proficiency and attitudes toward technology. Data were collected at baseline and at 6 and 12 months post-randomization. The PRISM group reported significantly less loneliness and increased perceived social support and well-being at 6 months. There was a trend indicating a decline in social isolation. Group differences were not maintained at 12 months, but those in the PRISM condition still showed improvements from baseline. There was also an increase in computer self-efficacy, proficiency, and comfort with computers for PRISM participants at 6 and 12 months. The findings suggest that access to technology applications such as PRISM may enhance social connectivity and reduce loneliness among older adults and has the potential to change attitudes toward technology and increase technology self-efficacy.
NASA Astrophysics Data System (ADS)
Zhang, Hao; Yuan, Yan; Su, Lijuan; Huang, Fengzhen; Bai, Qing
2016-09-01
The Risley-prism-based light beam steering apparatus delivers superior pointing accuracy and it is used in imaging LIDAR and imaging microscopes. A general model for pointing error analysis of the Risley prisms is proposed in this paper, based on ray direction deviation in light refraction. This model captures incident beam deviation, assembly deflections, and prism rotational error. We derive the transmission matrixes of the model firstly. Then, the independent and cumulative effects of different errors are analyzed through this model. Accuracy study of the model shows that the prediction deviation of pointing error for different error is less than 4.1×10-5° when the error amplitude is 0.1°. Detailed analyses of errors indicate that different error sources affect the pointing accuracy to varying degree, and the major error source is the incident beam deviation. The prism tilting has a relative big effect on the pointing accuracy when prism tilts in the principal section. The cumulative effect analyses of multiple errors represent that the pointing error can be reduced by tuning the bearing tilting in the same direction. The cumulative effect of rotational error is relative big when the difference of these two prism rotational angles equals 0 or π, while it is relative small when the difference equals π/2. The novelty of these results suggests that our analysis can help to uncover the error distribution and aid in measurement calibration of Risley-prism systems.
Tunnel Vision Prismatic Field Expansion: Challenges and Requirements
Apfelbaum, Henry; Peli, Eli
2015-01-01
Purpose No prismatic solution for peripheral field loss (PFL) has gained widespread acceptance. Field extended by prisms has a corresponding optical scotoma at the prism apices. True expansion can be achieved when each eye is given a different view (through visual confusion). We analyze the effects of apical scotomas and binocular visual confusion in different designs to identify constraints on any solution that is likely to meet acceptance. Methods Calculated perimetry diagrams were compared to perimetry with PFL patients wearing InWave channel prisms and Trifield spectacles. Percept diagrams illustrate the binocular visual confusion. Results Channel prisms provide no benefit at primary gaze. Inconsequential extension was provided by InWave prisms, although accessible with moderate gaze shifts. Higher-power prisms provide greater extension, with greater paracentral scotoma loss, but require uncomfortable gaze shifts. Head turns, not eye scans, are needed to see regions lost to the apical scotomas. Trifield prisms provide field expansion at all gaze positions, but acceptance was limited by disturbing effects of central binocular visual confusion. Conclusions Field expansion when at primary gaze (where most time is spent) is needed while still providing unobstructed central vision. Paracentral multiplexing prisms we are developing that superimpose shifted and see-through views may accomplish that. Translational Relevance Use of the analyses and diagramming techniques presented here will be of value when considering prismatic aids for PFL, and could have prevented many unsuccessful designs and the improbable reports we cited from the literature. New designs must likely address the challenges identified here. PMID:26740910
Tunnel Vision Prismatic Field Expansion: Challenges and Requirements.
Apfelbaum, Henry; Peli, Eli
2015-12-01
No prismatic solution for peripheral field loss (PFL) has gained widespread acceptance. Field extended by prisms has a corresponding optical scotoma at the prism apices. True expansion can be achieved when each eye is given a different view (through visual confusion). We analyze the effects of apical scotomas and binocular visual confusion in different designs to identify constraints on any solution that is likely to meet acceptance. Calculated perimetry diagrams were compared to perimetry with PFL patients wearing InWave channel prisms and Trifield spectacles. Percept diagrams illustrate the binocular visual confusion. Channel prisms provide no benefit at primary gaze. Inconsequential extension was provided by InWave prisms, although accessible with moderate gaze shifts. Higher-power prisms provide greater extension, with greater paracentral scotoma loss, but require uncomfortable gaze shifts. Head turns, not eye scans, are needed to see regions lost to the apical scotomas. Trifield prisms provide field expansion at all gaze positions, but acceptance was limited by disturbing effects of central binocular visual confusion. Field expansion when at primary gaze (where most time is spent) is needed while still providing unobstructed central vision. Paracentral multiplexing prisms we are developing that superimpose shifted and see-through views may accomplish that. Use of the analyses and diagramming techniques presented here will be of value when considering prismatic aids for PFL, and could have prevented many unsuccessful designs and the improbable reports we cited from the literature. New designs must likely address the challenges identified here.
Comment on Schuster's Technique for Focusing the Prism Spectrometer.
ERIC Educational Resources Information Center
Beynon, John
1991-01-01
Discussed is the physics that underpins Schuster's technique for obtaining a parallel light beam for use in various prism and grating experiments. Basic physics concepts using geometrical optics of prism, together with elementary differential calculus are explained as well as the mechanics of Schuster's technique. (KR)
21 CFR 886.5810 - Ophthalmic prism reader.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a...
NASA Astrophysics Data System (ADS)
Garcia-Molina, Rafael; del Mazo, Alejandro; Velasco, Santiago
2018-01-01
We present a simple and cheap experimental setup that clearly shows how the colors of the white light spectrum after passing a prism do not recombine when emerging from an identical second prism, as it is still found in many references.
ERIC Educational Resources Information Center
Garcia-Molina, Rafael; del Mazo, Alejandro; Velasco, Santiago
2018-01-01
We present a simple and cheap experimental setup that clearly shows how the colors of the white light spectrum after passing a prism do not recombine when emerging from an identical second prism, as it is still found in many references.
Optical power splitter for splitting high power light
English, R.E. Jr.; Christensen, J.J.
1995-04-18
An optical power splitter for the distribution of high-power light energy has a plurality of prisms arranged about a central axis to form a central channel. The input faces of the prisms are in a common plane which is substantially perpendicular to the central axis. A beam of light which is substantially coaxial to the central axis is incident on the prisms and at least partially strikes a surface area of each prism input face. The incident beam also partially passes through the central channel. 5 figs.
Strongly-Refractive One-Dimensional Photonic Crystal Prisms
NASA Technical Reports Server (NTRS)
Ting, David Z. (Inventor)
2004-01-01
One-dimensional (1D) photonic crystal prisms can separate a beam of polychromatic electromagnetic waves into constituent wavelength components and can utilize unconventional refraction properties for wavelength dispersion over significant portions of an entire photonic band rather than just near the band edges outside the photonic band gaps. Using a ID photonic crystal simplifies the design and fabrication process and allows the use of larger feature sizes. The prism geometry broadens the useful wavelength range, enables better optical transmission, and exhibits angular dependence on wavelength with reduced non-linearity. The properties of the 1 D photonic crystal prism can be tuned by varying design parameters such as incidence angle, exit surface angle, and layer widths. The ID photonic crystal prism can be fabricated in a planar process, and can be used as optical integrated circuit elements.
Development of salt production technology using prism greenhouse method
NASA Astrophysics Data System (ADS)
Guntur, G.; Jaziri, A. A.; Prihanto, A. A.; Arisandi, D. M.; Kurniawan, A.
2018-01-01
The main problem of salt production in Indonesia is low productivity and quality because the technology used commonly by Indonesian salt farmers is traditional method. This research aims to increase production of salt by using the prism greenhouse method. The prism greenhouse method is a salt production system with a combination of several salt production technologies, including geomembrane, threaded filter, and prism greenhouse technology. This research method used descriptive method. The results of this study were the productivity increased threefold, and the quality of salt produced also increased in terms of the content of NaCl from 85% to 95%. In addition, salt production with the prism greenhouse method has several advantages, such as faster harvest time, weather resistance, easy to use, and higher profit than traditional methods.
NASA Astrophysics Data System (ADS)
Jurado, Maria Jose
2016-04-01
IODP has extensively used the D/V Chikyu to drill the Kumano portion of the Nankai Trough, including two well sites within the Kumano Basin. IODP Expeditions 338 and 348 drilled deep into the inner accretionary prism south of the Kii Peninsula collecting a suite of LWD data, including natural gamma ray, electrical resistivity logs and borehole images, suitable to characterize structures (fractures and faults) inside the accretionary prism. Structural interpretation and analysis of logging-while-drilling data in the deep inner prism revealed intense deformation of a generally homogenous lithology characterized by bedding that dips steeply (60-90°) to the NW, intersected by faults and fractures. Multiple phases of deformation are characterized. IODP Expedition borehole images and LWD data acquired in the last decade in previous and results of NantroSEIZE IODP Expeditions (314, 319) were also analyzed to investigate the internal geometries and structures of the Nankai Trough accretionary prism. This study focused mainly on the characterization of the different types of structures and their specific position within the accretionary prism structures. New structural constraints and methodologies as well as a new approach to the characterization of study of active structures inside the prism will be presented.
Volckmann, Pierre; Jacquin-Courtois, Sophie
2016-01-01
Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations. PMID:27668094
Jacquin-Courtois, S; Rode, G; Pavani, F; O'Shea, J; Giard, M H; Boisson, D; Rossetti, Y
2010-03-01
Unilateral neglect is a disabling syndrome frequently observed following right hemisphere brain damage. Symptoms range from visuo-motor impairments through to deficient visuo-spatial imagery, but impairment can also affect the auditory modality. A short period of adaptation to a rightward prismatic shift of the visual field is known to improve a wide range of hemispatial neglect symptoms, including visuo-manual tasks, mental imagery, postural imbalance, visuo-verbal measures and number bisection. The aim of the present study was to assess whether the beneficial effects of prism adaptation may generalize to auditory manifestations of neglect. Auditory extinction, whose clinical manifestations are independent of the sensory modalities engaged in visuo-manual adaptation, was examined in neglect patients before and after prism adaptation. Two separate groups of neglect patients (all of whom exhibited left auditory extinction) underwent prism adaptation: one group (n = 6) received a classical prism treatment ('Prism' group), the other group (n = 6) was submitted to the same procedure, but wore neutral glasses creating no optical shift (placebo 'Control' group). Auditory extinction was assessed by means of a dichotic listening task performed three times: prior to prism exposure (pre-test), upon prism removal (0 h post-test) and 2 h later (2 h post-test). The total number of correct responses, the lateralization index (detection asymmetry between the two ears) and the number of left-right fusion errors were analysed. Our results demonstrate that prism adaptation can improve left auditory extinction, thus revealing transfer of benefit to a sensory modality that is orthogonal to the visual, proprioceptive and motor modalities directly implicated in the visuo-motor adaptive process. The observed benefit was specific to the detection asymmetry between the two ears and did not affect the total number of responses. This indicates a specific effect of prism adaptation on lateralized processes rather than on general arousal. Our results suggest that the effects of prism adaptation can extend to unexposed sensory systems. The bottom-up approach of visuo-motor adaptation appears to interact with higher order brain functions related to multisensory integration and can have beneficial effects on sensory processing in different modalities. These findings should stimulate the development of therapeutic approaches aimed at bypassing the affected sensory processing modality by adapting other sensory modalities.
Berndtson, Allison E; Sen, Soman; Greenhalgh, David G; Palmieri, Tina L
2013-09-01
The purpose of our study is to validate the Pediatric Risk of Mortality (PRISM) score and compare the accuracy of PRISM predicted outcomes to the Abbreviated Burn Severity Index (ABSI). We hypothesized that the PRISM score is more accurate in predicting mortality and hospital length of stay than the ABSI in children with severe burns. All children <18 years of age admitted to a regional pediatric burn center between January 1, 2008 and July 1, 2010 were reviewed. Those with a Total Body Surface Area (TBSA) burn ≥20% who were admitted within 7 days of injury were selected for our study. Measured parameters included: demographics, burn characteristics, PRISM and ABSI scores at admission, and outcomes (mortality, hospital length of stay (LOS), ventilator days and cause of death). A total of 83 patients met criteria and had complete data sets. The mean age (±SEM) was 8.0±0.6 years, mean % TBSA burn 49.9±2.1%, 62.7% were male, and 45.8% had inhalation injury. Hospital LOS was 74.4±7.9 days, with 31.5±4.9 ventilator days. Mean PRISM score ranged from 14.2 to 16.0, with ABSI scores 7.9 to 8.5. Actual overall mortality was 18.1% compared to a PRISM predicted mortality of 19.8±2.5% (p<0.001, r=0.570). ABSI predicted mortality varied from 10 to 20% for a score of 7.9 to 30-50% for a score of 8.5. Logistic regression showed that both PRISM (p<0.001) and ABSI (p<0.001) mortality predictions accurately estimated actual mortality, which remained true in a combined model. ABSI was predictive of hospital LOS (p<0.001) and ventilator days (p<0.001) while PRISM was not (p=0.326 and p=0.863). Both PRISM and ABSI scores are predictive of mortality in severely burned children. Only ABSI correlates with hospital length of stay and ventilator days, and thus may also be more useful in predicting ICU resource utilization. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
[Do prisms according to Hans-Joachim Haase improve stereoacuity?].
Kromeier, Miriam; Schmitt, Christina; Bach, Michael; Kommerell, Guntram
2002-06-01
The "Measuring and Correcting Methodology" after H.-J. Haase (MKH) aims at converting "fixation disparity" into bicentral fixation, using prismatic spectacles. In the context of the MKH, fixation disparity is diagnosed by a series of subjective tests. According to H.-J. Haase, a long-standing fixation disparity can lead to "disparate correspondence" between the central areas of both retinae, which consolidates the fixation disparity and gradually converts a "young" into an "old fixation disparity". In "old fixation disparity" it is thought that bicentral fixation does not occur anymore, so that stereoacuity is impaired. However, prismatic spectacles can, according to H.-J. Haase, restitute bicentral fixation and consequently improve stereoacuity, even in some cases of "old fixation disparity". Ten non-strabismic subjects with a visual acuity of >/= 1.0 in both eyes were examined. It turned out that all ten had, according to MKH, a "disparate correspondence", 5 subjects with a "young" and 5 with an "old fixation disparity". According to the MKH, a correcting prism was determined. All 10 subjects underwent the automatic Freiburg Stereoacuity Test, without and with the MKH-prism. Without the MKH-prism, the stereoscopic threshold ranged between 1.5 and 14.5 arcsec. With the MKH-prism, the values were not significantly different. Stereoacuity ranged between good and excellent in the 5 subjects with "young" as well as in the 5 subjects with "old fixation disparity". The MKH-prism did not improve the stereoacuity in any of the subjects. These results cast doubt on Haase's assertion that an "old fixation disparity" implies a reduced stereoacuity. Hence, the premise for a benefit of the MKH-prism with respect of stereoacuity is not substantiated. In the 5 subjects with a "young fixation disparity", the good stereoacuity is consistent with Haase's theory, so that a benefit of the MKH-prism for stereoacuity was not expected. In previous studies, stereoacuity was found to be better with the MKH-prism than without it. These studies are questionable since learning with repeated testing was not taken into account. We conclude that there is no sound evidence for the assumption that the MKH-prism can improve stereoacuity.
Microstructural features of carious human enamel imaged with back-scattered electrons.
Pearce, E I; Nelson, D G
1989-02-01
We have used back-scattered electrons (BE) in the scanning electron microscope to produce mineral density images of enamel. Flat surfaces of artificially-carious enamel, softened in an intra-oral experiment, and naturally-carious (white spot) enamel were polished to a high gloss with diamond lapping compound, rendering them almost featureless by secondary electron scanning electron microscopy. They were then examined at 10 to 30 kV in a Philips 505 instrument fitted with a 4-quadrant BE detector. Study of surfaces prepared approximately parallel to the natural surface showed that mineral was lost from both prism core and the interprismatic region, leaving a thin mineral-rich rim at the prism periphery. The same lesions viewed longitudinally on a surface prepared perpendicular to the natural surface showed mineral-rich bands at the prism margins in the outer enamel. Near the advancing front of the lesion, the prism junctions were widened and the prism cores sometimes hypermineralized. Natural lesions sectioned in the prism long axis showed features previously seen with other techniques, e.g., cross-striations and striae of Retzius, but in much greater detail. Mineral enrichment at the prism periphery in the lesion body and a widening of the prism junction at the advancing fronts of lesions in permanent teeth were most obvious. Calculations showed that with an accelerating voltage of 30 kV, the images reflected mineral density up to 4 microns beneath the surface. BE microscopy produces a high-resolution image of mineral loss or gain in carious enamel, with relatively easy sample preparation.
Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics
ERIC Educational Resources Information Center
Planinsic, Gorazd; Gojkosek, Mihael
2011-01-01
Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…
Investigating First Year Elementary Mathematics Teacher Education Students' Knowledge of Prism
ERIC Educational Resources Information Center
Bozkurt, Ali; Koc, Yusuf
2012-01-01
The purpose of this study was to investigate first year elementary mathematics teacher education students' knowledge of prism. For this goal, the participants were asked to define the geometric concept of prism. The participants were 158 first year elementary mathematics teacher education students from a public university in Southern Turkey. The…
Left to Right: Representational Biases for Numbers and the Effect of Visuomotor Adaptation
ERIC Educational Resources Information Center
Loftus, Andrea M.; Nicholls, Michael E. R.; Mattingley, Jason B.; Bradshaw, John L.
2008-01-01
Adaptation to right-shifting prisms improves left neglect for mental number line bisection. This study examined whether adaptation affects the mental number line in normal participants. Thirty-six participants completed a mental number line task before and after adaptation to either: left-shifting prisms, right-shifting prisms or control…
The formation of ammonium cobalt (II) phosphate was utilized to synthesize unprecedented 3D structures of Co3O4, triangular prisms and trunk-like structures, via a self-supported and organics-free method. The length of a triangular side of the prepared 3D triangular prisms is ~1...
PRISM Climate Group, Oregon State U
FAQ PRISM Climate Data The PRISM Climate Group gathers climate observations from a wide range of monitoring networks, applies sophisticated quality control measures, and develops spatial climate datasets to reveal short- and long-term climate patterns. The resulting datasets incorporate a variety of modeling
NASA Technical Reports Server (NTRS)
Pishnyak, Oleg; Kreminska, Lyubov; Laventovich, Oleg D.; Pouch, John J.; Miranda, Felix A.; Winker, Bruce K.
2004-01-01
We describe digital beam deflectors (DBDs) based on liquid crystals. Each stage of the device comprises a polarization rotator and a birefringent prism deflector. The birefringent prism deflects the beam by an angle that depends on polarization of the incident beam. The prism can be made of the uniaxial smectic A (SmA) liquid crystal (LC) or a solid crystal such as yttrium orthovanadate (YVO4). SmA prisms have high birefringence and can be constructed in a variety of shapes, including single prisms and prismatic blazed gratings of different angles and profiles. We address the challenges of uniform alignment of SmA, such as elimination of focal conic domains. Rotation of linear polarization is achieved by an electrically switched twisted nematic (TN) cell. A DBD composed of N rotator-deflector pairs steers the beam into 2(sup N) directions. As an example, we describe a four-stage DBD deflecting normally incident laser beam within the range of +/- 56 mrad with 8 mrad steps. Redirection of the beam is achieved by switching the TN cells.
The Program for Regional and International Shorebird Monitoring (PRISM)
Bart, J.; Andres, B.; Brown, S.; Donaldson, G.; Harrington, B.; Johnston, V.; Jones, S.; Morrison, R.I.G.; Skagen, S.K.
2005-01-01
This report describes the "Program for Regional and International Shorebird Monitoring" (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird conservation plans recently completed in Canada and the United States. The goals of PRISM are to (1) estimate the size of breeding population of 74 shorebird taxa in North America; (2) describe the distribution, abundance, and habitat relationships for each of these taxa; (3) monitor trends in shorebird population size; (4) monitor shorebird numbers at stopover locations, and; (5) assist local managers in meeting their shorebird conservation goals. PRISM has four main components: arctic and boreal breeding surveys, temperate breeding surveys, temperate non-breeding surveys, and neotropical surveys. Progress on, and action items for, each major component are described. The more important major tasks for immediate action are carrying out the northern surveys, conducting regional analyses to design the program of migration counts, and evaluating aerial photographic surveys for migration and winter counts.
NASA Astrophysics Data System (ADS)
Ehrhart, Matthias; Lienhart, Werner
2017-09-01
The importance of automated prism tracking is increasingly triggered by the rising automation of total station measurements in machine control, monitoring and one-person operation. In this article we summarize and explain the different techniques that are used to coarsely search a prism, to precisely aim at a prism, and to identify whether the correct prism is tracked. Along with the state-of-the-art review, we discuss and experimentally evaluate possible improvements based on the image data of an additional wide-angle camera which is available for many total stations today. In cases in which the total station's fine aiming module loses the prism, the tracked object may still be visible to the wide-angle camera because of its larger field of view. The theodolite angles towards the target can then be derived from its image coordinates which facilitates a fast reacquisition of the prism. In experimental measurements we demonstrate that our image-based approach for the coarse target search is 4 to 10-times faster than conventional approaches.
Two-photon laser scanning microscopy with electrowetting-based prism scanning
Supekar, Omkar D.; Ozbay, Baris N.; Zohrabi, Mo; Nystrom, Philip D.; Futia, Gregory L.; Restrepo, Diego; Gibson, Emily A.; Gopinath, Juliet T.; Bright, Victor M.
2017-01-01
Laser scanners are an integral part of high resolution biomedical imaging systems such as confocal or 2-photon excitation (2PE) microscopes. In this work, we demonstrate the utility of electrowetting on dielectric (EWOD) prisms as a lateral laser-scanning element integrated in a conventional 2PE microscope. To the best of our knowledge, this is the first such demonstration for EWOD prisms. EWOD devices provide a transmissive, low power consuming, and compact alternative to conventional adaptive optics, and hence this technology has tremendous potential. We demonstrate 2PE microscope imaging of cultured mouse hippocampal neurons with a FOV of 130 × 130 μm2 using EWOD prism scanning. In addition, we show simulations of the optical system with the EWOD prism, to evaluate the effect of propagating a Gaussian beam through the EWOD prism on the imaging quality. Based on the simulation results a beam size of 0.91 mm full width half max was chosen to conduct the imaging experiments, resulting in a numerical aperture of 0.17 of the imaging system. PMID:29296477
Genomes to natural products PRediction Informatics for Secondary Metabolomes (PRISM)
Skinnider, Michael A.; Dejong, Chris A.; Rees, Philip N.; Johnston, Chad W.; Li, Haoxin; Webster, Andrew L. H.; Wyatt, Morgan A.; Magarvey, Nathan A.
2015-01-01
Microbial natural products are an invaluable source of evolved bioactive small molecules and pharmaceutical agents. Next-generation and metagenomic sequencing indicates untapped genomic potential, yet high rediscovery rates of known metabolites increasingly frustrate conventional natural product screening programs. New methods to connect biosynthetic gene clusters to novel chemical scaffolds are therefore critical to enable the targeted discovery of genetically encoded natural products. Here, we present PRISM, a computational resource for the identification of biosynthetic gene clusters, prediction of genetically encoded nonribosomal peptides and type I and II polyketides, and bio- and cheminformatic dereplication of known natural products. PRISM implements novel algorithms which render it uniquely capable of predicting type II polyketides, deoxygenated sugars, and starter units, making it a comprehensive genome-guided chemical structure prediction engine. A library of 57 tailoring reactions is leveraged for combinatorial scaffold library generation when multiple potential substrates are consistent with biosynthetic logic. We compare the accuracy of PRISM to existing genomic analysis platforms. PRISM is an open-source, user-friendly web application available at http://magarveylab.ca/prism/. PMID:26442528
Porous Ni-Co-Mn oxides prisms for high performance electrochemical energy storage
NASA Astrophysics Data System (ADS)
Zhao, Jianbo; Li, Man; Li, Junru; Wei, Chengzhen; He, Yuyue; Huang, Yixuan; Li, Qiaoling
2017-12-01
Porous Ni-Co-Mn oxides prisms have been successfully synthesized via a facile route. The process involves the preparation of nickel-cobalt-manganese acetate hydroxide by a simple co-precipitation method and subsequently the thermal treatment. The as-synthesized Ni-Co-Mn oxides prisms had a large surface area (96.53 m2 g-1) and porous structure. As electrode materials for supercapacitors, porous Ni-Co-Mn oxides prisms showed a high specific capacitance of 1623.5 F g-1 at 1.0 A g-1. Moreover, the porous Ni-Co-Mn oxides prisms were also employed as positive electrode materials to assemble flexible solid-state asymmetric supercapacitors. The resulting flexible device had a maximum volumetric energy density (0.885 mW h cm-3) and power density (48.9 mW cm-3). Encouragingly, the flexible device exhibited good cycling stability with only about 2.2% loss after 5000 charge-discharge cycles and excellent mechanical stability. These results indicate that porous Ni-Co-Mn oxides prisms have the promising application in high performance electrochemical energy storage.
Beam splitter and method for generating equal optical path length beams
Qian, Shinan; Takacs, Peter
2003-08-26
The present invention is a beam splitter for splitting an incident beam into first and second beams so that the first and second beams have a fixed separation and are parallel upon exiting. The beam splitter includes a first prism, a second prism, and a film located between the prisms. The first prism is defined by a first thickness and a first perimeter which has a first major base. The second prism is defined by a second thickness and a second perimeter which has a second major base. The film is located between the first major base and the second major base for splitting the incident beam into the first and second beams. The first and second perimeters are right angle trapezoidal shaped. The beam splitter is configured for generating equal optical path length beams.
PRISM Spectrograph Optical Design
NASA Technical Reports Server (NTRS)
Chipman, Russell A.
1995-01-01
The objective of this contract is to explore optical design concepts for the PRISM spectrograph and produce a preliminary optical design. An exciting optical configuration has been developed which will allow both wavelength bands to be imaged onto the same detector array. At present the optical design is only partially complete because PRISM will require a fairly elaborate optical system to meet its specification for throughput (area*solid angle). The most complex part of the design, the spectrograph camera, is complete, providing proof of principle that a feasible design is attainable. This camera requires 3 aspheric mirrors to fit inside the 20x60 cm cross-section package. A complete design with reduced throughput (1/9th) has been prepared. The design documents the optical configuration concept. A suitable dispersing prism material, CdTe, has been identified for the prism spectrograph, after a comparison of many materials.
Forward and inverse solutions for Risley prism based on the Denavit-Hartenberg methodology
NASA Astrophysics Data System (ADS)
Beltran-Gonzalez, A.; Garcia-Torales, G.; Strojnik, M.; Flores, J. L.; Garcia-Luna, J. L.
2017-08-01
In this work forward and inverse solutions for two-element Risley prism for pointing and scanning beam systems are developed. A more efficient and faster algorithm is proposed to make an analogy of the Risley prism system compared with a robotic system with two degrees of freedom. This system of equations controls each Risley prism individually as a planar manipulator arm of two links. In order to evaluate the algorithm we implement it in a pointing system. We perform popular routines such as the linear, spiral and loops traces. Using forward and inverse solutions for two-element Risley prism it is also possible to point at coordinates specified by the user, provided they are within the pointer area of work area. Experimental results are showed as a validation of our proposal.
Schintu, Selene; Pisella, Laure; Jacobs, Stéphane; Salemme, Romeo; Reilly, Karen T; Farnè, Alessandro
2014-01-01
Rightward prism adaptation has been shown to ameliorate visuospatial biases in right brain-damaged patients with neglect, and a single session of prism adaptation can lead to improvements that last up to several hours. Leftward prism adaptation in neurologically healthy individuals induces neglect-like biases in visuospatial tasks. The duration of these effects in healthy individuals, typically assumed to be ephemeral, has never been investigated. Here we assessed the time-course of the adaptation-induced modifications in a classical perceptual line bisection task that was repeatedly administered for approximately 40min after a single session of adaptation to either a leftward or rightward prismatic deviation. Consistent with previous reports, only adaptation to leftward-deviating prisms induced a visuospatial shift on perceptual line bisection judgments. The typical pattern of pseudoneglect was counteracted by a rightward shift in midline judgments, which became significant between 5 and 10 min after adaptation, fluctuated between being significant or not several times in the 40 min following adaptation, and was present as late as 35 min. In contrast, the sensorimotor aftereffect was present immediately after adaptation to both rightward and leftward deviating prisms, decayed initially then remained stable until 40 min. These results demonstrate that both the sensorimotor and visuospatial effects last for at least 35 min, but that the visuospatial shift needs time to fully develop and fluctuates. By showing that the effects of prism adaptation in the undamaged brain are not ephemeral, these findings reveal the presence of another, so-far neglected dimension in the domain of the cognitive effects induced by prism adaptation, namely time. The prolonged duration of the induced visuospatial shift, previously considered to be a feature of prism adaptation unique to brain-damaged subjects, also applies to the normal brain. © 2013 Published by Elsevier Ltd.
Hashimoto, Yuji; Honda, Takeru; Matsumura, Ken; Nakao, Makoto; Soga, Kazumasa; Katano, Kazuhiko; Yokota, Takanori; Mizusawa, Hidehiro; Nagao, Soichi; Ishikawa, Kinya
2015-01-01
The cerebellum plays important roles in motor coordination and learning. However, motor learning has not been quantitatively evaluated clinically. It thus remains unclear how motor learning is influenced by cerebellar diseases or aging, and is related with incoordination. Here, we present a new application for testing human cerebellum-dependent motor learning using prism adaptation. In our paradigm, the participant wearing prism-equipped goggles touches their index finger to the target presented on a touchscreen in every trial. The whole test consisted of three consecutive sessions: (1) 50 trials with normal vision (BASELINE), (2) 100 trials wearing the prism that shifts the visual field 25° rightward (PRISM), and (3) 50 trials without the prism (REMOVAL). In healthy subjects, the prism-induced finger-touch error, i.e., the distance between touch and target positions, was decreased gradually by motor learning through repetition of trials. We found that such motor learning could be quantified using the "adaptability index (AI)", which was calculated by multiplying each probability of [acquisition in the last 10 trials of PRISM], [retention in the initial five trials of REMOVAL], and [extinction in the last 10 trials of REMOVAL]. The AI of cerebellar patients less than 70 years old (mean, 0.227; n = 62) was lower than that of age-matched healthy subjects (0.867, n = 21; p < 0.0001). While AI did not correlate with the magnitude of dysmetria in ataxic patients, it declined in parallel with disease progression, suggesting a close correlation between the impaired cerebellar motor leaning and the dysmetria. Furthermore, AI decreased with aging in the healthy subjects over 70 years old compared with that in the healthy subjects less than 70 years old. We suggest that our paradigm of prism adaptation may allow us to quantitatively assess cerebellar motor learning in both normal and diseased conditions.
Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Sun, Xuefei; Gao, Yuqian
2013-07-05
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a medianmore » CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM-SRM quantification of low-abundance cellular proteins in systems biology studies as well as candidate biomarkers in biofluids.« less
Hashimoto, Yuji; Honda, Takeru; Matsumura, Ken; Nakao, Makoto; Soga, Kazumasa; Katano, Kazuhiko; Yokota, Takanori; Mizusawa, Hidehiro; Nagao, Soichi; Ishikawa, Kinya
2015-01-01
The cerebellum plays important roles in motor coordination and learning. However, motor learning has not been quantitatively evaluated clinically. It thus remains unclear how motor learning is influenced by cerebellar diseases or aging, and is related with incoordination. Here, we present a new application for testing human cerebellum-dependent motor learning using prism adaptation. In our paradigm, the participant wearing prism-equipped goggles touches their index finger to the target presented on a touchscreen in every trial. The whole test consisted of three consecutive sessions: (1) 50 trials with normal vision (BASELINE), (2) 100 trials wearing the prism that shifts the visual field 25° rightward (PRISM), and (3) 50 trials without the prism (REMOVAL). In healthy subjects, the prism-induced finger-touch error, i.e., the distance between touch and target positions, was decreased gradually by motor learning through repetition of trials. We found that such motor learning could be quantified using the “adaptability index (AI)”, which was calculated by multiplying each probability of [acquisition in the last 10 trials of PRISM], [retention in the initial five trials of REMOVAL], and [extinction in the last 10 trials of REMOVAL]. The AI of cerebellar patients less than 70 years old (mean, 0.227; n = 62) was lower than that of age-matched healthy subjects (0.867, n = 21; p < 0.0001). While AI did not correlate with the magnitude of dysmetria in ataxic patients, it declined in parallel with disease progression, suggesting a close correlation between the impaired cerebellar motor leaning and the dysmetria. Furthermore, AI decreased with aging in the healthy subjects over 70 years old compared with that in the healthy subjects less than 70 years old. We suggest that our paradigm of prism adaptation may allow us to quantitatively assess cerebellar motor learning in both normal and diseased conditions. PMID:25785588
Robach, J S; Stock, S R; Veis, A
2009-12-01
Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass spectroscopy). The study focused on the internal structure of the first-stage mineral structures of high Mg calcite (primary, secondary and carinar process plates, prisms) and on morphology of the columns of second-stage mineral (very high Mg calcite) that cement the first-stage material together. Optical micrographs under polarized light revealed contrast in the centers (midlines) of carinar process plates and in prisms in polished sections; staining of primary and carinar process plates revealed significant dye uptake at the plate centers. Demineralization with and without fixation revealed that the midlines of primary and carinar process plates (but not secondary plates) and the centers of prisms differed from the rest of the plate or prism, and SIMS showed proteins concentrated in these plate centers. SEM was used to study the morphology of columns, the fracture surfaces of mature teeth and the 3D morphology of prisms. These observations of internal structures in plates and prisms offer new insight into the mineralization process and suggest an important role for protein inclusions within the first-stage mineral. Some of the 3D structures not reported previously, such as twisted prisms and stacks of carinar process plates with nested wrinkles, may represent structural strengthening strategies.
PRISM Software: Processing and Review Interface for Strong‐Motion Data
Jones, Jeanne M.; Kalkan, Erol; Stephens, Christopher D.; Ng, Peter
2017-01-01
A continually increasing number of high‐quality digital strong‐motion records from stations of the National Strong Motion Project (NSMP) of the U.S. Geological Survey, as well as data from regional seismic networks within the United States, calls for automated processing of strong‐motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong‐motion records. When used without AQMS, PRISM provides batch‐processing capabilities. The PRISM software is platform independent (coded in Java), open source, and does not depend on any closed‐source or proprietary software. The software consists of two major components: a record processing engine composed of modules for each processing step, and a review tool, which is a graphical user interface for manual review, edit, and processing. To facilitate use by non‐NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand‐alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible to accommodate implementation of new processing techniques. All the computing features have been thoroughly tested.
Monari, Paola; Pelizzari, Laura; Crotti, Silvia; Damiani, Giovanni; Calzavara-Pinton, Piergiacomo; Gualdi, Giulio
2015-11-01
PRISM (Pictorial Representation of Illness and Self Measure) is a nonverbal visualization instrument. The authors chose to use this tool to avoid the limitation of the other tests for the assessment of quality of life by using interview methods that depend on the cognitive and cultural level of the patient. The aim of the study was to assess the impact on the quality of life of different types of chronic wounds using the PRISM test. The PRISM test was administered by the same medical student to each patient visiting the dermatology department for a routine visit and medication. The PRISM test was administered to 77 patients with chronic cutaneous ulcers referred to the Dermatology Department of the Spedali Civili of Brescia, Italy. The authors analyzed the "Self-llness-Separation"' (SIS) value, which resulted from the PRISM test, and related it to sex, age, and ulcer etiology. Considering all categories, the mean SIS was 9.58 cm; a different perception of the disease between the sexes was noted and also in the subgroups based on the ulcer's different etiology. In addition, the age of the affected patients influenced the SIS value. PRISM is an easy and sensitive instrument to record information about the patient's expectations and suffering in order to improve the overall physician-patient relationship.
Niedermann, Karin; de Bie, Rob A; Kubli, Regula; Ciurea, Adrian; Steurer-Stey, Claudia; Villiger, Peter M; Büchi, Stefan
2011-01-01
the modern joint protection (JP) concept for people with rheumatoid arthritis (RA) is an active coping strategy to improve daily tasks and role performance by changing working methods and using assistive devices. Effective group JP education includes psycho-educational interventions. The Pictorial Representation of Illness and Self Measure (PRISM) is an interactive hands-on-tool, assessing (a) the individual's perceived burden of illness and (b) relevant individual resources. Both issues are important for intrinsic motivation to take action and change behaviour. This study compared individual conventional JP education (C-JP) with PRISM-based JP education (PRISM-JP). an assessor-blinded multicentre randomized controlled trial, including four JP education sessions over 3 weeks, with assessments at baseline and 3 months. in total 53 RA patients participated. At 3 months, the PRISM-JP (n=26) participants did significantly better compared to the C-JP participants (n=27) in JP behaviour (p=0.02 and p=0.008 when corrected for baseline values), Arthritis Self-efficacy (ASES, p=0.015) and JP self-efficacy (JP-SES, p=0.047). Within-group analysis also showed less hand pain (p<0.001) in PRISM-JP group. PRISM-JP more effectively supported learning of JP methods, with meaningful occupations, resource activation and self-efficacy acting as important mediators. PRISM improved patient-clinician communication and is feasible for occupational therapy. 2010 Elsevier Ireland Ltd. All rights reserved.
Iverson, N.R.; Hooyer, T.S.; Fischer, U.H.; Cohen, D.; Moore, P.L.; Jackson, M.; Lappegard, G.; Kohler, J.
2007-01-01
To avoid some of the limitations of studying soft-bed processes through boreholes, a prism of simulated till (1.8 m ?? 1.6 m ?? 0.45 m) with extensive instrumentation was constructed in a trough blasted in the rock bed of Engabreen, a temperate glacier in Norway. Tunnels there provide access to the bed beneath 213 m of ice. Pore-water pressure was regulated in the prism by pumping water to it. During experiments lasting 7-12 days, the glacier regelated downward into the prism to depths of 50-80 mm, accreting ice-infiltrated till at rates predicted by theory. During periods of sustained high pore-water pressure (70-100% of overburden), ice commonly slipped over the prism, due to a water layer at the prism surface. Deformation of the prism was activated when this layer thinned to a sub-millimeter thickness. Shear strain in the till was pervasive and decreased with depth. A model of slip by ploughing of ice-infiltrated till across the prism surface accounts for the slip that occurred when effective pressure was sufficiently low or high. Slip at low effective pressures resulted from water-layer thickening that increased non-linearly with decreasing effective pressure. If sufficiently widespread, such slip over soft glacier beds, which involves no viscous deformation resistance, may instigate abrupt increases in glacier velocity.
Robach, J. S.; Stock, S. R.; Veis, A.
2009-01-01
Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass spectroscopy). The study focused on the internal structure of the first-stage mineral structures of high Mg calcite (primary, secondary and carinar process plates; prisms) and on morphology of the columns of second-stage mineral (very high Mg calcite) that cement the first-stage material together. Optical micrographs under polarized light revealed contrast in the centers (midlines) of carinar process plates and in prisms in polished sections; staining of primary and carinar process plates revealed significant dye uptake at the plate centers. Demineralization with and without fixation revealed that the midlines of primary and carinar process plates (but not secondary plates) and the centers of prisms differed from the rest of the plate or prism, and SIMS showed proteins concentrated in these plate centers. SEM was used to study the morphology of columns, the fracture surfaces of mature teeth and the 3D morphology of prisms. These observations of internal structures in plates and prisms offer new insight into the mineralization process and suggest an important role for protein inclusions within the first-stage mineral. Some of the 3D structures not reported previously, such as twisted prisms and stacks of carinar process plates with nested wrinkles, may represent structural strengthening strategies. PMID:19616101
Calibration of the Wedge Prism
Charles B. Briscoe
1957-01-01
Since the introduction of plotless cruising in this country by Grosenbaugh and the later suggestion of using a wedge prism as an angle gauge by Bruce this method of determining basal area has been widely adopted in the South. One of the factors contributing to the occasionally unsatisfactory results obtained is failure to calibrate the prism used. As noted by Bruce the...
2010-08-01
In this work, a novel electro - optic beam switch (EOBS) is designed, fabricated and demonstrated. The EOBS presented in this work is designed for a...consists of a series of electronically controlled prisms fabricated by ferroelectric domain inversion in an electro - optic crystal wafer. The prisms are
Multibeam collimator uses prism stack
NASA Technical Reports Server (NTRS)
Minott, P. O.
1981-01-01
Optical instrument creates many divergent light beams for surveying and machine element alignment applications. Angles and refractive indices of stack of prisms are selected to divert incoming laser beam by small increments, different for each prism. Angles of emerging beams thus differ by small, precisely-controlled amounts. Instrument is nearly immune to vibration, changes in gravitational force, temperature variations, and mechanical distortion.
A Longitudinal Study of Prism Adaptation in Infants from Six to Nine Months of Age.
ERIC Educational Resources Information Center
McDonnell, Paul M.; Abraham, Wayne C.
1981-01-01
Confirms that aftereffects of prism adaptation can be obtained in infants between 5 and 9 months of age and that the magnitude of these aftereffects is comparable to those found in adult studies. Evidence of a shift in hand preference toward the direction of prism displacement was replicated. (Author/RH)
1991-06-05
2 Prism Dye Amplifiers .................................................................................. 2 Axicon...carried out under this project. PRISM DYE AMPLIFIERS A first effort was devoted to setting up an amplifier system for the output of a short pulse dye laser...For amplification up to pulse energies of approximately 500 p.J/pulse we chose three stages of prism amplifier cells, with diameters of 1 m, 3 mm
XeCl excimer laser with new prism resonator configurations and its performance characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benerji, N. S., E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in; Singh, A.; Varshnay, N.
2015-07-15
New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configurationmore » with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.« less
XeCl excimer laser with new prism resonator configurations and its performance characteristics.
Benerji, N S; Singh, A; Varshnay, N; Singh, Bijendra
2015-07-01
New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configuration with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.
Accretionary processes along the Middle America Trench off Costa Rica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shipley, T.H.; Stoffa, P.L.; McIntosh, K.
1990-06-01
The geometry of large-scale structures within modern accretionary prisms is known entirely from seismic reflection studies using single or grids of two-dimensional profiles. Off Costa Rica the authors collected a three-dimensional reflection data set covering a 9 km wide {times} 22 km long {times} 6 km thick volume of the accretionary prism just arcward of the Middle America Trench. The three-dimensional processing and ability to examine the prism as a volume has provided the means to map structures from a few hundred meters to kilometers in size with confidence. Reflections from within the prism define the gross structural features andmore » tectonic processes active along this particular portion of the Middle America Trench. So far in the analysis, these data illustrate the relationships between the basement, the prism shape, and overlying slope sedimentary deposits. For instance, the subducted basement relief (of several hundred meters amplitude) does seem to affect the larger scale through-going faults within the prism. Offscraping of the uppermost 45 m of sediments occurs within 4 km of the trench creating a small pile of sediments at the base of the trench. How this offscraped sediment is incorporated into the prism is still being investigated. Underplating of parts of the 400 m thick subducted section begin: at a very shallow structural level, 4 to 10 km arcward of the trench. Amplitude anomalies associated with some of the larger arcward dipping structures in the prism and surface mud volcanoes suggest that efficient fluid migration paths may extend from the top of the downgoing slab at the shelf edge out into the lower and middle slope region, a distance of 50 to 100 km.« less
Büchi, S; Straub, S; Schwager, U
2010-12-01
Although there is much talk about shared decision making and individualized goal setting, there is a lack of knowledge and knowhow in their realization in daily clinical practice. There is a lack in tools for easy applicable tools to ameliorate person-centred individualized goal setting processes. In three selected psychiatric inpatients the semistructured, theory driven use of PRISM (Pictorial Representation of Illness and Self Measure) in patients with complex psychiatric problems is presented and discussed. PRISM sustains a person-centred individualized process of goal setting and treatment and reinforces the active participation of patients. The process of visualisation and synchronous documentation is validated positively by patients and clinicians. The visual goal setting requires 30 to 45 minutes. In patients with complex psychiatric illness PRISM was used successfully to ameliorate individual goal setting. Specific effects of PRISM-visualisation are actually evaluated in a randomized controlled trial.
Direct view zoom scope with single focal plane and adaptable reticle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bagwell, Brett
A direct view telescopic sight includes objective lens, eyepiece, and prism erector assemblies. The objective lens assembly is mounted to receive light of an image from an object direction and direct the light along an optical path. The eyepiece assembly is mounted to receive the light along the optical path and to emit the light of the image along an eye-ward direction. The prism erector assembly is positioned between the objective lens and eyepiece assemblies and includes first and second prism elements through which the optical path passes. The first and second prism elements invert the image. A reticle elementmore » is disposed on or adjacent to a surface of one of the first or second prism elements to combine a reticle on the image. The image is brought into focus at only a single focal plane between the objective lens and eyepiece assemblies at a given time.« less
A test of point-sampling in northern hardwoods
Dale S. Solomon
1975-01-01
Plot- and point-sampling were compared with a complete inventory of two different stands of northern hardwoods. Prisms with basal-area factors of 5, 10, 20, 30, and 40 and a ¼-acre plot were used. Only the 5-factor prism gave a significantly different estimate. Therefore, a prism factor of 10 or greater is suggested for use in northern hardwoods.
A bi-prism interferometer for hard x-ray photons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isakovic, A.F.; Siddons, D.; Stein, A.
2010-04-06
Micro-fabricated bi-prisms have been used to create an interference pattern from an incident hard X-ray beam, and the intensity of the pattern probed with fluorescence from a 30 nm-thick metal film. Maximum fringe visibility exceeded 0.9 owing to the nano-sized probe and the choice of single-crystal prism material. A full near-field analysis is necessary to describe the fringe field intensities, and the transverse coherence lengths were extracted at APS beamline 8-ID-I. It is also shown that the maximum number of fringes is dependent only on the complex refractive index of the prism material.
PRISM software—Processing and review interface for strong-motion data
Jones, Jeanne M.; Kalkan, Erol; Stephens, Christopher D.; Ng, Peter
2017-11-28
Rapidly available and accurate ground-motion acceleration time series (seismic recordings) and derived data products are essential to quickly providing scientific and engineering analysis and advice after an earthquake. To meet this need, the U.S. Geological Survey National Strong Motion Project has developed a software package called PRISM (Processing and Review Interface for Strong-Motion data). PRISM automatically processes strong-motion acceleration records, producing compatible acceleration, velocity, and displacement time series; acceleration, velocity, and displacement response spectra; Fourier amplitude spectra; and standard earthquake-intensity measures. PRISM is intended to be used by strong-motion seismic networks, as well as by earthquake engineers and seismologists.
Hendrix, James Lee
2001-05-08
A Porro prism and a light polarizer are combined in a single optical element termed a Hendrix Prism. The design provides retro-reflection of incoming light of a predetermined polarization in a direction anti-parallel to the direction of light incidence, while reflecting undesired light, i.e., that having a polarization orthogonal to the predetermined polarization, from the surface of the light polarizer. The undesired light is reflected in a direction that does not interfere with the intended operation of the device in which the Hendrix Prism is installed yet provides feedback to the system in which it is used.
Analytical models for the groundwater tidal prism and associated benthic water flux
King, Jeffrey N.; Mehta, Ashish J.; Dean, Robert G.
2010-01-01
The groundwater tidal prism is defined as the volume of water that inundates a porous medium, forced by one tidal oscillation in surface water. The pressure gradient that generates the prism acts on the subterranean estuary. Analytical models for the groundwater tidal prism and associated benthic flux are presented. The prism and flux are shown to be directly proportional to porosity, tidal amplitude, and the length of the groundwater wave; flux is inversely proportional to tidal period. The duration of discharge flux exceeds the duration of recharge flux over one tidal period; and discharge flux continues for some time following low tide. Models compare favorably with laboratory observations and are applied to a South Atlantic Bight study area, where tide generates an 11-m3 groundwater tidal prism per m of shoreline, and drives 81 m3 s −1 to the study area, which describes 23% of an observational estimate. In a marine water body, the discharge component of any oscillatory benthic water flux is submarine groundwater discharge. Benthic flux transports constituents between groundwater and surface water, and is a process by which pollutant loading and saltwater intrusion may occur in coastal areas.
Fu, Tao; Wang, Jing; Levin, Moran; Su, Qing; Li, Dongguo; Li, Junfa
2015-01-01
Purpose. To measure the changes in fusional vergence in Chinese children with intermittent exotropia (IXT) and the association with the control of IXT. Methods. Ninety-two patients with IXT (8-15 years old) were compared with 86 controls. Exodeviation control was evaluated using the Revised Newcastle Control Score. Angle of deviation was measured using prism and alternate cover testing at distance and near. Fusional vergence was measured using prism bar and synoptophore. This study was registered with ChiCTR-RCC-13003920. Results. Using prism bar, convergence break points were lower whereas divergence break points were higher in children with IXT at distance (P < 0.001) and near (P < 0.001) compared with controls. There was no significant difference in mean divergence amplitudes between the two groups when testing using a synoptophore (P = 0.53). In children with IXT, the distance between recovery point and break point in both convergence (distance: P = 0.02; near: P = 0.02) and divergence (distance: P < 0.001; near: P < 0.001) was larger than controls when detected by prism bar and synoptophore (convergence: P = 0.005; divergence: P = 0.006). Conclusions. Children with IXT have reduced convergence amplitudes as detected by both prism bar and synoptophore.
Genomes to natural products PRediction Informatics for Secondary Metabolomes (PRISM).
Skinnider, Michael A; Dejong, Chris A; Rees, Philip N; Johnston, Chad W; Li, Haoxin; Webster, Andrew L H; Wyatt, Morgan A; Magarvey, Nathan A
2015-11-16
Microbial natural products are an invaluable source of evolved bioactive small molecules and pharmaceutical agents. Next-generation and metagenomic sequencing indicates untapped genomic potential, yet high rediscovery rates of known metabolites increasingly frustrate conventional natural product screening programs. New methods to connect biosynthetic gene clusters to novel chemical scaffolds are therefore critical to enable the targeted discovery of genetically encoded natural products. Here, we present PRISM, a computational resource for the identification of biosynthetic gene clusters, prediction of genetically encoded nonribosomal peptides and type I and II polyketides, and bio- and cheminformatic dereplication of known natural products. PRISM implements novel algorithms which render it uniquely capable of predicting type II polyketides, deoxygenated sugars, and starter units, making it a comprehensive genome-guided chemical structure prediction engine. A library of 57 tailoring reactions is leveraged for combinatorial scaffold library generation when multiple potential substrates are consistent with biosynthetic logic. We compare the accuracy of PRISM to existing genomic analysis platforms. PRISM is an open-source, user-friendly web application available at http://magarveylab.ca/prism/. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
A comparative study of spherical and flat-Earth geopotential modeling at satellite elevations
NASA Technical Reports Server (NTRS)
Parrott, M. H.; Hinze, W. J.; Braile, L. W.; Vonfrese, R. R. B.
1985-01-01
Flat-Earth modeling is a desirable alternative to the complex spherical-Earth modeling process. These methods were compared using 2 1/2 dimensional flat-earth and spherical modeling to compute gravity and scalar magnetic anomalies along profiles perpendicular to the strike of variably dimensioned rectangular prisms at altitudes of 150, 300, and 450 km. Comparison was achieved with percent error computations (spherical-flat/spherical) at critical anomaly points. At the peak gravity anomaly value, errors are less than + or - 5% for all prisms. At 1/2 and 1/10 of the peak, errors are generally less than 10% and 40% respectively, increasing to these values with longer and wider prisms at higher altitudes. For magnetics, the errors at critical anomaly points are less than -10% for all prisms, attaining these magnitudes with longer and wider prisms at higher altitudes. In general, in both gravity and magnetic modeling, errors increase greatly for prisms wider than 500 km, although gravity modeling is more sensitive than magnetic modeling to spherical-Earth effects. Preliminary modeling of both satellite gravity and magnetic anomalies using flat-Earth assumptions is justified considering the errors caused by uncertainties in isolating anomalies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardiansyah, D.; Haryanto, F.; Male, S.
2014-09-30
Prism is a non-commercial Radiotherapy Treatment Planning System (RTPS) develop by Ira J. Kalet from Washington University. Inhomogeneity factor is included in Prism TPS dose calculation. The aim of this study is to investigate the sensitivity of dose calculation on Prism using Monte Carlo simulation. Phase space source from head linear accelerator (LINAC) for Monte Carlo simulation is implemented. To achieve this aim, Prism dose calculation is compared with EGSnrc Monte Carlo simulation. Percentage depth dose (PDD) and R50 from both calculations are observed. BEAMnrc is simulated electron transport in LINAC head and produced phase space file. This file ismore » used as DOSXYZnrc input to simulated electron transport in phantom. This study is started with commissioning process in water phantom. Commissioning process is adjusted Monte Carlo simulation with Prism RTPS. Commissioning result is used for study of inhomogeneity phantom. Physical parameters of inhomogeneity phantom that varied in this study are: density, location and thickness of tissue. Commissioning result is shown that optimum energy of Monte Carlo simulation for 6 MeV electron beam is 6.8 MeV. This commissioning is used R50 and PDD with Practical length (R{sub p}) as references. From inhomogeneity study, the average deviation for all case on interest region is below 5 %. Based on ICRU recommendations, Prism has good ability to calculate the radiation dose in inhomogeneity tissue.« less
NASA Astrophysics Data System (ADS)
Zhao, Yuejin
1996-06-01
In this paper, a new method for image stabilization with a three-axis image- stabilizing reflecting prism assembly is presented, and the principle of image stabilization in this prism assembly, formulae for image stabilization and working formulae with an approximation up to the third power are given in detail. In this image-stabilizing system, a single chip microcomputer is used to calculate value of compensating angles and thus to control the prism assembly. Two gyroscopes act as sensors from which information of angular perturbation is obtained, three stepping motors drive the prism assembly to compensate for the movement of image produced by angular perturbation. The image-stabilizing device so established is a multifold system which involves optics, mechanics, electronics and computer.
Explaining negative refraction without negative refractive indices.
Talalai, Gregory A; Garner, Timothy J; Weiss, Steven J
2018-03-01
Negative refraction through a triangular prism may be explained without assigning a negative refractive index to the prism by using array theory. For the case of a beam incident upon the wedge, the array theory accurately predicts the beam transmission angle through the prism and provides an estimate of the frequency interval at which negative refraction occurs. The hypotenuse of the prism has a staircase shape because it is built of cubic unit cells. The large phase delay imparted by each unit cell, combined with the staircase shape of the hypotenuse, creates the necessary conditions for negative refraction. Full-wave simulations using the finite-difference time-domain method show that array theory accurately predicts the beam transmission angle.
Single-Frequency Nd:YAG Ring Lasers with Corner Cube Prism
NASA Astrophysics Data System (ADS)
Wu, Ke-Ying; Yang, Su-Hui; Zhao, Chang-Ming; Wei, Guang-Hui
2000-10-01
We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single-frequency generating power. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix.
The infrared bands Pechan prism axis parallel detection method
NASA Astrophysics Data System (ADS)
Qiang, Hua; Ji, Ming; He, Yu-lan; Wang, Nan-xi; Chang, Wei-jun; Wang, Ling; Liu, Li
2017-02-01
In this paper, we put forward a new method to adjust the air gap of the total reflection air gap of the infrared Pechan prism. The adjustment of the air gap in the air gap of the Pechan prism directly affects the parallelism of the optical axis, so as to affect the consistency of the optical axis of the infrared system. The method solves the contradiction between the total reflection and the high transmission of the infrared wave band, and promotes the engineering of the infrared wave band. This paper puts forward the method of adjusting and controlling, which can ensure the full reflection and high penetration of the light, and also can accurately measure the optical axis of the optical axis of the different Pechan prism, and can achieve the precision of the level of the sec. For Pechan prism used in the infrared band image de rotation, make the product to realize miniaturization, lightweight plays an important significance.
Maintaining a stationary laser footprint during angular scan in internal-reflection experiments.
Fontana, Eduardo; Cavalcanti, Gustavo Oliveira
2013-11-10
In internal-reflection metrology using prisms, the prism is usually mounted on a rotation/translation stage to enable adjusting angle and location of the laser footprint on the surface. If a visual inspection method is used to find the laser footprint, the task becomes impossible if invisible radiation in the near infrared is employed. In addition, it may be desirable to perform angular scan experiments with a stationary footprint on the surface during scans, or even to automatically probe specific points on an extended prism face for predetermined incidence angles. In this paper, a formulation is developed to determine the required translation along the prism face to allow maintaining the laser footprint stationary under a given rotation. A web-based app developed under the scope of this work demonstrates the applicability of the approach for silica, BK7 and SF2 glasses, in the wavelength range from 500 to 1500 nm and for an arbitrary geometry of the glass prism.
Esfahlani, Hussein; Karkar, Sami; Lissek, Herve; Mosig, Juan R
2016-01-07
The optical dispersive prism is a well-studied element, which allows separating white light into its constituent spectral colors, and stands in nature as water droplets. In analogy to this definition, the acoustic dispersive prism should be an acoustic device with capability of splitting a broadband acoustic wave into its constituent Fourier components. However, due to the acoustical nature of materials as well as the design and fabrication difficulties, there is neither any natural acoustic counterpart of the optical prism, nor any artificial design reported so far exhibiting an equivalent acoustic behaviour. Here, based on exotic properties of the acoustic transmission-line metamaterials and exploiting unique physical behaviour of acoustic leaky-wave radiation, we report the first acoustic dispersive prism, effective within the audible frequency range 800 Hz-1300 Hz. The dispersive nature, and consequently the frequency-dependent refractive index of the metamaterial are exploited to split the sound waves towards different and frequency-dependent directions. Meanwhile, the leaky-wave nature of the structure facilitates the sound wave radiation into the ambient medium.
NASA Astrophysics Data System (ADS)
Kaur, Gurpreet; Tomar, Monika; Gupta, Vinay
2015-11-01
ZnO thin film was deposited on gold coated glass prism by RF sputtering technique in glancing angle deposition (GLAD) configuration. The structural, morphological and optical properties of the deposited film were investigated using X-ray diffraction (XRD), Atomic Force Microscopy (AFM) and Fourier Transform Infrared (FTIR) Spectroscopy. ZnO coated Au prisms (ZnO/Au/prism) were used to excite surface plasmons in Kretschmann configuration at the Au- ZnO interface on a laboratory assembled Surface Plasmon Resonance (SPR) measurement setup. Cholesterol oxidase (ChOx) enzyme was immobilized on the ZnO/Au/prism structure by physical adsorption technique. Polydimethylsiloxane (PDMS) microchannels were fabricated over ChOx/ZnO/Au/prism system and various concentrations of cholesterol were passed over the sensor surface. The concentration of cholesterol was varied from 0.12 to 10.23 mM and the SPR reflectance curves were recorded in both static as well as dynamic modes demonstrating a high sensitivity of 0.36° mM-1.
A metasurface-based prism analogue for terahertz rainbow spectrum manipulation
NASA Astrophysics Data System (ADS)
Zheng, Shen; Li, Chao; Li, Shichao; Zhang, Xiaojuan; Fang, Guangyou
2017-06-01
Optical prisms can spread compound light spatially into a rainbow and have widespread applications in spectroscopy and imaging. Limited by the natural materials as well as technologies, there has been no natural counterpart of the optical prism that works in the Terahertz (THz) band so far. In this letter, a THz prism analogue based on metasurfaces working in the transmission diffraction mechanism is first proposed to generate the THz rainbow spectrum. The physics of different modes excited by the interaction between the incident wave and the metasurface is investigated in theory and simulation. A coherent enhancement method was developed to improve the mode competition of the rainbow spectrum over other unwanted leaky modes to guarantee the high transfer efficiency of the wavelength dependent transmission diffraction. The experimental results show that the prism analogue can spread the incident spectrum from 0.15 to 0.22 THz in an angular scope of about 30.8° with comparatively high transferring efficiency.
Unstable Resonator Retrofitted Handheld Laser Designator
1978-06-01
retrofitted with a negative-branch unstable resona- tor laser and hybrid pump cavity in place of the conventional plane-mirror/ porro prism resonator and...directed by prism B to an expanding telescope, shared with the viewing system of the designator. The actual, unfolded resonator length is approxi...was performed based on using a plane- parallel cavity consisting of a 47% reflectivity output coupler, porro - prism reflector, and the same LiNb03
JPRS Report, Science & Technology, USSR: Electronics & Electrical Engineering.
1988-12-14
of Angle Measurement on Orientation of Porro Prism in Interferometer [G. A. Lenkova; AVTOMETRIYA, No 2, Mar-Apr 88] 33 Laser-Doppler Anemometer With...Measurement on Orientation of Porro Prism in Interferometer 18600122e Novosibirsk A VTOMETRIYA in Russian No 2, Mar-Apr 88 (manuscript received 19...identical Porro prisms being mounted rigidly on a common support and sym- metrically with respect to the axis of rotation. The range of measurable
Beyond the Sensorimotor Plasticity: Cognitive Expansion of Prism Adaptation in Healthy Individuals.
Michel, Carine
2015-01-01
Sensorimotor plasticity allows us to maintain an efficient motor behavior in reaction to environmental changes. One of the classical models for the study of sensorimotor plasticity is prism adaptation. It consists of pointing to visual targets while wearing prismatic lenses that shift the visual field laterally. The conditions of the development of the plasticity and the sensorimotor after-effects have been extensively studied for more than a century. However, the interest taken in this phenomenon was considerably increased since the demonstration of neglect rehabilitation following prism adaptation by Rossetti et al. (1998). Mirror effects, i.e., simulation of neglect in healthy individuals, were observed for the first time by Colent et al. (2000). The present review focuses on the expansion of prism adaptation to cognitive functions in healthy individuals during the last 15 years. Cognitive after-effects have been shown in numerous tasks even in those that are not intrinsically spatial in nature. Altogether, these results suggest the existence of a strong link between low-level sensorimotor plasticity and high-level cognitive functions and raise important questions about the mechanisms involved in producing unexpected cognitive effects following prism adaptation. Implications for the functional mechanisms and neuroanatomical network of prism adaptation are discussed to explain how sensorimotor plasticity may affect cognitive processes.
Li, Ping; Zhou, Yong; Zhao, Zongyan; Xu, Qinfeng; Wang, Xiaoyong; Xiao, Min; Zou, Zhigang
2015-08-05
An unprecedented, crystal facet-based CeO2 homojunction consisting of hexahedron prism-anchored octahedron with exposed prism surface of {100} facets and octahedron surface of {111} facets was fabricated through solution-based crystallographic-oriented epitaxial growth. The photocatalysis experiment reveals that growth of the prism arm on octahedron allows to activate inert CeO2 octahedron for an increase in phototocatalytic reduction of CO2 into methane. The pronounced photocatalytic performance is attributed to a synergistic effect of the following three factors: (1) band alignment of the {100} and {111} drives electrons and holes to octahedron and prism surfaces, respectively, aiming to reach the most stable energy configuration and leading to a spatial charge separation for long duration; (2) crystallographic-oriented epitaxial growth of the CeO2 hexahedron prism arm on the octahedron verified by the interfacial lattice fringe provides convenient and fast channels for the photogenerated carrier transportation between two units of homojuntion; (3) different effective mass of electrons and holes on {100} and {111} faces leads to high charge carrier mobility, more facilitating the charge separation. The proposed facet-based homojunction in this work may provide a new concept for the efficient separation and fast transfer of photoinduced charge carriers and enhancement of the photocatalytic performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enrico Clement, Carlos; Park, Sung-Yong, E-mail: mpeps@nus.edu.sg
2016-05-09
A high degree of beam steering is demonstrated using an electrowetting-driven liquid prism. While prism devices have typically relied on complex and expensive laboratory setups, such as high-vacuum facilities for fabrication of dielectric layers, this work utilizes a simple dip-coating method to provide an ion gel layer as a dielectric, offering 2 or 3 orders higher specific capacitance (c ≈ 10 μF/cm{sup 2}) than that of conventional dielectrics. Analytical studies present the effects of liquid selection and arrangement on overall prism performance. For experimental demonstrations of high-performance beam steering, we not only selected two immiscible liquids of water and 1-bromonaphthalene (1-BN)more » oil which provide the large refractive index difference (n{sub water} = 1.33 and n{sub 1-BN} = 1.65 at λ = 532 nm) between them, but also utilized a double-stacked prism configuration which increases the number of interfaces for incoming light to be steered. At a prism apex angle of φ = 27°, we were able to achieve significantly large beam steering of up to β = 19.06°, which is the highest beam steering performance ever demonstrated using electrowetting technology.« less
Hamada, Yohei; Kitamura, Manami; Yamada, Yasuhiro; Sanada, Yoshinori; Sugihara, Takamitsu; Saito, Saneatsu; Moe, Kyaw; Hirose, Takehiro
2018-02-14
A new method for evaluating the in situ rock strength beneath the seafloor is proposed and applied to the Nankai Trough accretionary prism. The depth-continuous in situ rock strength is a critical parameter for numerous studies in earth science, particularly for seismology and tectonics at plate convergence zones; yet, measurements are limited owing to a lack of drilled cores. Here, we propose a new indicator of strength, the equivalent strength (EST), which is determined only by drilling performance parameters such as drill string rotational torque, bit depth, and string rotational speed. A continuous depth profile of EST was drawn from 0 to 3000 m below the seafloor (mbsf) across the forearc basin and accretionary prism in the Nankai Trough. The EST did not show a significant increase around the forearc basin-accretionary prism boundary, but it did show a clear increase within the prism, ca. below 1500 mbsf. This result may indicate that even the shallow accretionary prism has been strengthened by horizontal compression derived from plate subduction. The EST is a potential parameter to continuously evaluate the in situ rock strength during drilling, and its accuracy of the absolute value can be improved by combining with laboratory drilling experiments.
Precise optical observation of 0.5-GPa shock waves in condensed materials
NASA Astrophysics Data System (ADS)
Nagayama, Kunihito; Mori, Yasuhito
1999-06-01
Precision optical observation method was developed to study impact-generated high-pressure shock waves in condensed materials. The present method makes it possible to sensitively detect the shock waves of the relatively low shock stress around 0.5 GPa. The principle of the present method is based on the use of total internal reflection by triangular prisms placed on the free surface of a target assembly. When a plane shock wave arrives at the free surface, the light reflected from the prisms extinguishes instantaneously. The reason is that the total internal reflection changes to the reflection depending on micron roughness of the free surface after the shock arrival. The shock arrival at the bottom face of the prisms can be detected here by two kinds of methods, i.e., a photographic method and a gauge method. The photographic method is an inclined prism method of using a high-speed streak camera. The shock velocity and the shock tilt angle can be estimated accurately from an obtained streak photograph. While in the gauge method, an in-material PVDF stress gauge is combined with an optical prism-pin. The PVDF gauge records electrically the stress profile behind the shockwave front, and the Hugoniot data can be precisely measured by combining the prism pin with the PVDF gauge.
Beyond the Sensorimotor Plasticity: Cognitive Expansion of Prism Adaptation in Healthy Individuals
Michel, Carine
2016-01-01
Sensorimotor plasticity allows us to maintain an efficient motor behavior in reaction to environmental changes. One of the classical models for the study of sensorimotor plasticity is prism adaptation. It consists of pointing to visual targets while wearing prismatic lenses that shift the visual field laterally. The conditions of the development of the plasticity and the sensorimotor after-effects have been extensively studied for more than a century. However, the interest taken in this phenomenon was considerably increased since the demonstration of neglect rehabilitation following prism adaptation by Rossetti et al. (1998). Mirror effects, i.e., simulation of neglect in healthy individuals, were observed for the first time by Colent et al. (2000). The present review focuses on the expansion of prism adaptation to cognitive functions in healthy individuals during the last 15 years. Cognitive after-effects have been shown in numerous tasks even in those that are not intrinsically spatial in nature. Altogether, these results suggest the existence of a strong link between low-level sensorimotor plasticity and high-level cognitive functions and raise important questions about the mechanisms involved in producing unexpected cognitive effects following prism adaptation. Implications for the functional mechanisms and neuroanatomical network of prism adaptation are discussed to explain how sensorimotor plasticity may affect cognitive processes. PMID:26779088
On the tidal prism-channel area relations
NASA Astrophysics Data System (ADS)
D'Alpaos, Andrea; Lanzoni, Stefano; Marani, Marco; Rinaldo, Andrea
2010-03-01
We verify the broad applicability of tidal prism cross-sectional area relationships, originally proposed to relate the total water volume entering a lagoon during a characteristic tidal cycle (the tidal prism) to the size of its inlet, to arbitrary sheltered cross sections within a tidal network. We suggest, with reasonable approximation defining a statistical tendency rather than a pointwise equivalence, that the regime of tidal channels may be anywhere related to local landscape-forming prisms embedded in a characteristic spring tide oscillation. The importance of the proposed extension stems from its potential for quantitative predictions of the long-term morphological evolution of whole tidal landforms, in response to forcings affecting tidal prisms. This is the case, in particular, for alterations of relative mean sea levels possibly driven by climate change. Various 1-D and 2-D morphodynamic and hydrodynamic models are employed to evaluate peak flow rates, bottom shear stresses, and the ensuing local tidal prisms. One-dimensional morphodynamic models describing both the longitudinal and cross-sectional evolution of tidal channels are used to verify the validity of the relationship for sheltered sections. Relevant hydrodynamic features determined through accurate 2-D numerical models are compared with those obtained through time-invariant equivalents, defining a mean watershed by an energy landscape from averaged free surface gradients. Empirical evidence gathered within the lagoon of Venice (Italy) supports the proposed extension. We conclude that the geomorphic law relating tidal prisms to channel cross-sectional areas anywhere within a tidal landscape is a valuable tool for studies on long-term tidal geomorphology.
NASA Astrophysics Data System (ADS)
Penney, C.; Tavakoli, F.; Saadat, A.; Nankali, H. R.; Sedighi, M.; Khorrami, F.; Sobouti, F.; Rafi, Z.; Copley, A.; Jackson, J. A.; Priestley, K. F.
2017-12-01
The Makran is one of the world's least-studied subduction zones. In particular, little is known about the accumulation and accommodation of strain in the onshore part of the subduction zone, which parallels the coasts of southern Iran and Pakistan. The deformation of the Makran accretionary prism results from both its subduction zone setting and N-S right-lateral shear between central Iran and Afghanistan. North of the Makran, this shear is accommodated by a series of right-lateral faults which offset the rocks of the Sistan Suture Zone, an abandoned accretionary prism. However, these right-lateral faults are not observed south of 27°N, and no major N-S faults cut the E-W trending structures of the Makran. How this right-lateral motion is accommodated at the southern end of the Sistan Suture Zone is a long-standing tectonic question. By combining results from geomorphology, GPS, seismology and modelling we conclude that right-lateral motion is transferred across the depression north of the accretionary prism to the region of right-lateral shear at the western end of the accretionary prism. This requires the Jaz Murian depression to be bounded by normal faults, consistent with the basin geomorphology. However, GPS data show compression across the margins of the basin, and no shallow normal-faulting earthquakes have been observed in the region. We therefore suggest that the behaviour of these faults may be time-dependent and controlled by the megathrust seismic cycle, as has been suggested elsewhere (e.g. Chile). Recent strike-slip earthquakes, including the 2013 Balochistan earthquake, have clustered at the prism's lateral edges, showing the importance of spatial, as well as temporal, variations in strain. These earthquakes have reactivated thrust faults in the Makran accretionary prism, showing that the style of strain within accretionary prisms can vary on multiple timescales and allowing us to calculate the coefficient of friction on the underlying megathrust.
Prism adaptation does not alter object-based attention in healthy participants.
Bultitude, Janet H; List, Alexandra; Aimola Davies, Anne M
2013-01-01
Hemispatial neglect ('neglect') is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the proposal that prism adaptation may only perturb cognitive functions for which normal baseline performance is already biased.
TRMM-3B43 Bias Correction over the High Elevations of the Contiguous United States
NASA Astrophysics Data System (ADS)
Hashemi, H.; Nordin, K. M.; Lakshmi, V.; Knight, R. J.
2016-12-01
Precipitation can be quantified using a rain gauge network, or a remotely sensed precipitation product. Ultimately, the choice of dataset depends on the particular application, the catchment size, climate and the time period of study. In a region with a long record and a dense rain gauge network, the elevation-modified ground-based precipitation product, PRISM, has been found to work well. However, in poorly gauged regions the use of remotely sensed precipitation products is an absolute necessity. The Tropical Rainfall Measuring Mission (TRMM) has provided valuable precipitation datasets for hydrometeorological studies over the past two decades (1998-2015). One concern regarding the usage of TRMM data is the accuracy of the precipitation estimates, when compared to those obtained using PRISM. The reason for this concern is that TRMM and PRISM do not always agree and, typically, TRMM underestimates PRISM over the mountainous regions of the United States. In this study, we develop a correction function to improve the accuracy of the TRMM monthly product (TRMM-3B43) by estimating and removing the bias in the satellite data using the ground-based precipitation product, PRISM. We observe a strong relationship between the bias and land surface elevation; TRMM-3B43 tends to underestimate the PRISM product at altitudes greater than 1500 m above mean sea level (m.amsl) in the contiguous United States. A relationship is developed between TRMM-PRISM bias and elevation. The correction function is used to adjust the TRMM monthly precipitation using PRISM and elevation data. The model is calibrated using 25% of the available time period and the remaining 75% of the time period is used for validation. The corrected TRMM-3B43 product is verified for the high elevations over the contiguous United States and two local regions in the mountainous areas of the western United States. The results show a significant improvement in the accuracy of the TRMM product in the high elevations of the contiguous United States.
PRISM, Processing and Review Interface for Strong Motion Data Software
NASA Astrophysics Data System (ADS)
Kalkan, E.; Jones, J. M.; Stephens, C. D.; Ng, P.
2016-12-01
A continually increasing number of high-quality digital strong-motion records from stations of the National Strong Motion Project (NSMP) of the U.S. Geological Survey (USGS), as well as data from regional seismic networks within the U.S., calls for automated processing of strong-motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. PRISM automates the processing of strong-motion records by providing batch-processing capabilities. The PRISM software is platform-independent (coded in Java), open-source, and does not depend on any closed-source or proprietary software. The software consists of two major components: a record processing engine composed of modules for each processing step, and a graphical user interface (GUI) for manual review and processing. To facilitate the use by non-NSMP earthquake engineers and scientists, PRISM (both its processing engine and GUI components) is easy to install and run as a stand-alone system on common operating systems such as Linux, OS X and Windows. PRISM was designed to be flexible and extensible in order to accommodate implementation of new processing techniques. Input to PRISM currently is limited to data files in the Consortium of Organizations for Strong-Motion Observation Systems (COSMOS) V0 format, so that all retrieved acceleration time series need to be converted to this format. Output products include COSMOS V1, V2 and V3 files as: (i) raw acceleration time series in physical units with mean removed (V1), (ii) baseline-corrected and filtered acceleration, velocity, and displacement time series (V2), and (iii) response spectra, Fourier amplitude spectra and common earthquake-engineering intensity measures (V3). A thorough description of the record processing features supported by PRISM is presented with examples and validation results. All computing features have been thoroughly tested.
Prism adaptation does not alter object-based attention in healthy participants
Bultitude, Janet H.
2013-01-01
Hemispatial neglect (‘neglect’) is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the proposal that prism adaptation may only perturb cognitive functions for which normal baseline performance is already biased. PMID:24715960
Engaging Students in GeoPRISMS Science Planning: Preparing the Leaders of Tomorrow
NASA Astrophysics Data System (ADS)
Henning, A. T.; Benoit, M. H.; Marshall, J.; Goodliffe, A. M.; Morgan, J. K.; Bopp, C. J.
2011-12-01
GeoPRISMS is the legacy of the NSF MARGINS Program. It is a new decadal program, funded by NSF, committed to the amphibious study of the origin and evolution of continental margins through interdisciplinary, community-based investigations. MARGINS and GeoPRISMS have had notable success in fostering this team-based approach in graduate students who then continue on to become GeoPRISMS PIs. GeoPRISMS is enhancing its student outreach efforts through the development of a student symposium program, in which graduate students are invited to be more active participants in GeoPRISMS workshops, and are provided with valuable background and reference materials to enable them. This approach has been applied and updated at four GeoPRISMS workshops so far: two implementation workshops and two science planning workshops. Graduate students participated in the GeoPRISMS Rift Initiation and Evolution (RIE) implementation workshop in November 2010 and the Subduction Cycles and Deformation (SCD) workshop in January 2011, contributing to the overall design of the GeoPRISMS research program, and the selection of primary sites for study. In addition to participating in the regular meeting activities, students gave "pop-up" presentations to summarize their research and poster presentations and also worked together to develop their own draft implementation plan that was presented to the larger audience. Students responded positively to the experience of drafting their own implementation plans, which fostered a sense of community among participants and created an environment in which students felt comfortable speaking up during the meeting. Scientists attending the workshops were impressed by the students' draft implementation plans, as well as their work ethic and enthusiasm, and felt they made a very positive contribution to the workshops. Student feedback suggested providing students with a better understanding of the main scientific questions addressed at the meeting, as well as possible career paths. The sequestration of students during the workshop also raised concerns that they missed opportunities for broader community interactions. In Fall 2011, students participated in two symposia associated with the GeoPRISMS Alaska and Eastern North American Margin primary site planning workshops. The fall symposia followed a different model based on feedback from the first two workshops. A full day of activities took place prior to the workshop, including short presentations by experts in the field to provide background, a half-day field trip to enhance cohort-building, and student-only poster sessions and discussions. This approach allowed the students to participate fully in the meeting itself, with a stronger base of knowledge about the workshop topics and a larger network of colleagues.
Simple Tidal Prism Models Revisited
NASA Astrophysics Data System (ADS)
Luketina, D.
1998-01-01
Simple tidal prism models for well-mixed estuaries have been in use for some time and are discussed in most text books on estuaries. The appeal of this model is its simplicity. However, there are several flaws in the logic behind the model. These flaws are pointed out and a more theoretically correct simple tidal prism model is derived. In doing so, it is made clear which effects can, in theory, be neglected and which can not.
NASA Astrophysics Data System (ADS)
Ribeiro, Jair Lúcio Prados
2018-01-01
We only became aware of the existence of bed prism spectacles when a student brought them to the classroom and asked us about how they work. The device proved to be a fertile source of curiosity among the students, and, to be properly understood, it required us to develop a comparison between reflection in a typical mirror and total internal reflection in a prism. In this article we explain the physics behind this unfamiliar device, supported by geometrical optics principles.
Beam pointing direction changes in a misaligned Porro prism resonator
NASA Astrophysics Data System (ADS)
Lee, Jyh-Fa; Leung, Chung-Yee
1988-07-01
The relative change of the beam pointing direction for a misaligned Porro prism resonator has been analyzed, using an oscillation axis concept for the Porro prism resonator to find the beam direction. Expressions for the beam tilting angles are presented which show that the angular misalignment in the horizontal direction will result in beam tilting in both the horizontal and vertical directions. Good agreement between experimental and theoretical results is found.
Optimum Solar Conversion Cell Configurations
NASA Technical Reports Server (NTRS)
Chen, Bin (Inventor)
2015-01-01
Methods for maximizing a fraction of light energy absorbed in each of three classes of light concentrators (rectangular parallelepipeds, paraboloids and prisms) by choice of incident angle of radiation and of one or more geometrical or physical parameters (absorber thickness, paraboloid dimensions, location of paraboloid focus, prism angles, concentrator material, cladding, prism angles, etc.). Alternatively, the light energy absorbed plus the light energy that escapes through non-total internal reflection within the light concentrator can be minimized.
Full-wave simulation of a three-dimensional metamaterial prism
Basilio, Lorena I.; Langston, William L.; Warne, Larry K.; ...
2015-01-23
In our article, a negative-index metamaterial prism based on a composite unit cell containing a split-ring resonator and a z-dipole is designed and simulated. The design approach combines simulations of a single unit cell to identify the appropriate cell design (yielding the desired negative-index behavior) together with subcell modeling (which simplifies the mesh representation of the resonator geometry and allows for a larger number of resonator cells to be handled). Furthermore, to describe the methodology used in designing a n = -1 refractive index prism, our results include the effective-medium parameters, the far-field scattered patterns, and the near-zone field distributionsmore » corresponding to a normally incident plane-wave excitation of the prism.« less
Damage identification in cement paste amended with carbon nanotubes
NASA Astrophysics Data System (ADS)
Soltangharaei, Vafa; Anay, Rafal; Assi, Lateef; Ziehl, Paul; Matta, Fabio
2018-04-01
Cement-based composites have been used as reliable materials in building and civil engineering infrastructure for many decades. Although there are several advantages, some drawbacks such as premature cracking may be problematic for sensitive applications such as those found in nuclear power plants or associated waste storage facilities. In this study, acoustic emission monitoring was employed to detect stress waves associated with damage progression during uniaxial compressive loading. Acoustic emission data resulting from loading of plain cement paste prisms and cement paste prisms amended with carbon nanotubes are compared. Unsupervised pattern recognition is employed to categorize the data. Results indicate that increased acoustic emission activity was recorded for the plain cement paste prisms when compared to prisms amended with carbon nanotubes.
Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror
NASA Technical Reports Server (NTRS)
Li, Steven
2011-01-01
A laser cavity was designed and implemented by using a wedged polarization rotator and a Porro prism in order to reduce the parts count, and to improve the laser reliability. In this invention, a z-cut quartz polarization rotator is used to compensate the wavelength retardance introduced by the Porro prism. The polarization rotator rotates the polarization of the linear polarized beam with a designed angle that is independent of the orientation of the rotator. This unique property was used to combine the retardance compensation and a Risley prism to a single optical component: a wedged polarization rotator. This greatly simplifies the laser alignment procedure and reduces the number of the laser optical components.
Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji
2016-02-01
A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.
Hotchkiss, David R; Aqil, Anwer; Lippeveld, Theo; Mukooyo, Edward
2010-07-03
Sound policy, resource allocation and day-to-day management decisions in the health sector require timely information from routine health information systems (RHIS). In most low- and middle-income countries, the RHIS is viewed as being inadequate in providing quality data and continuous information that can be used to help improve health system performance. In addition, there is limited evidence on the effectiveness of RHIS strengthening interventions in improving data quality and use. The purpose of this study is to evaluate the usefulness of the newly developed Performance of Routine Information System Management (PRISM) framework, which consists of a conceptual framework and associated data collection and analysis tools to assess, design, strengthen and evaluate RHIS. The specific objectives of the study are: a) to assess the reliability and validity of the PRISM instruments and b) to assess the validity of the PRISM conceptual framework. Facility- and worker-level data were collected from 110 health care facilities in twelve districts in Uganda in 2004 and 2007 using records reviews, structured interviews and self-administered questionnaires. The analysis procedures include Cronbach's alpha to assess internal consistency of selected instruments, test-retest analysis to assess the reliability and sensitivity of the instruments, and bivariate and multivariate statistical techniques to assess validity of the PRISM instruments and conceptual framework. Cronbach's alpha analysis suggests high reliability (0.7 or greater) for the indices measuring a promotion of a culture of information, RHIS tasks self-efficacy and motivation. The study results also suggest that a promotion of a culture of information influences RHIS tasks self-efficacy, RHIS tasks competence and motivation, and that self-efficacy and the presence of RHIS staff have a direct influence on the use of RHIS information, a key aspect of RHIS performance. The study results provide some empirical support for the reliability and validity of the PRISM instruments and the validity of the PRISM conceptual framework, suggesting that the PRISM approach can be effectively used by RHIS policy makers and practitioners to assess the RHIS and evaluate RHIS strengthening interventions. However, additional studies with larger sample sizes are needed to further investigate the value of the PRISM instruments in exploring the linkages between RHIS data quality and use, and health systems performance.
Structural basis of mammalian glycan targeting by Vibrio cholerae cytolysin and biofilm proteins
De, Swastik; Kaus, Katherine; Sinclair, Shada
2018-01-01
Vibrio cholerae is an aquatic gram-negative microbe responsible for cholera, a pandemic disease causing life-threatening diarrheal outbreaks in populations with limited access to health care. Like most pathogenic bacteria, V. cholerae secretes virulence factors to assist colonization of human hosts, several of which bind carbohydrate receptors found on cell-surfaces. Understanding how pathogenic virulence proteins specifically target host cells is important for the development of treatment strategies to fight bacterial infections. Vibrio cholerae cytolysin (VCC) is a secreted pore-forming toxin with a carboxy-terminal β-prism domain that targets complex N-glycans found on mammalian cell-surface proteins. To investigate glycan selectivity, we studied the VCC β-prism domain and two additional β-prism domains found within the V. cholerae biofilm matrix protein RbmC. We show that the two RbmC β-prism domains target a similar repertoire of complex N-glycan receptors as VCC and find through binding and modeling studies that a branched pentasaccharide core (GlcNAc2-Man3) represents the likely footprint interacting with these domains. To understand the structural basis of V. cholerae β-prism selectivity, we solved high-resolution crystal structures of fragments of the pentasaccharide core bound to one RbmC β-prism domain and conducted mutagenesis experiments on the VCC toxin. Our results highlight a common strategy for cell-targeting utilized by both toxin and biofilm matrix proteins in Vibrio cholerae and provide a structural framework for understanding the specificity for individual receptors. Our results suggest that a common strategy for disrupting carbohydrate interactions could affect multiple virulence factors produced by V. cholerae, as well as similar β-prism domains found in other vibrio pathogens. PMID:29432487
Panico, Francesco; Sagliano, Laura; Grossi, Dario; Trojano, Luigi
2016-06-01
The aim of this study is to clarify the specific role of the cerebellum during prism adaptation procedure (PAP), considering its involvement in early prism exposure (i.e., in the recalibration process) and in post-exposure phase (i.e., in the after-effect, related to spatial realignment). For this purpose we interfered with cerebellar activity by means of cathodal transcranial direct current stimulation (tDCS), while young healthy individuals were asked to perform a pointing task on a touch screen before, during and after wearing base-left prism glasses. The distance from the target dot in each trial (in terms of pixels) on horizontal and vertical axes was recorded and served as an index of accuracy. Results on horizontal axis, that was shifted by prism glasses, revealed that participants who received cathodal stimulation showed increased rightward deviation from the actual position of the target while wearing prisms and a larger leftward deviation from the target after prisms removal. Results on vertical axis, in which no shift was induced, revealed a general trend in the two groups to improve accuracy through the different phases of the task, and a trend, more visible in cathodal stimulated participants, to worsen accuracy from the first to the last movements in each phase. Data on horizontal axis allow to confirm that the cerebellum is involved in all stages of PAP, contributing to early strategic recalibration process, as well as to spatial realignment. On vertical axis, the improving performance across the different stages of the task and the worsening accuracy within each task phase can be ascribed, respectively, to a learning process and to the task-related fatigue. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Salawu, Emmanuel Oluwatobi; Hesse, Evelyn; Stopford, Chris; Davey, Neil; Sun, Yi
2017-11-01
Better understanding and characterization of cloud particles, whose properties and distributions affect climate and weather, are essential for the understanding of present climate and climate change. Since imaging cloud probes have limitations of optical resolution, especially for small particles (with diameter < 25 μm), instruments like the Small Ice Detector (SID) probes, which capture high-resolution spatial light scattering patterns from individual particles down to 1 μm in size, have been developed. In this work, we have proposed a method using Machine Learning techniques to estimate simulated particles' orientation-averaged projected sizes (PAD) and aspect ratio from their 2D scattering patterns. The two-dimensional light scattering patterns (2DLSP) of hexagonal prisms are computed using the Ray Tracing with Diffraction on Facets (RTDF) model. The 2DLSP cover the same angular range as the SID probes. We generated 2DLSP for 162 hexagonal prisms at 133 orientations for each. In a first step, the 2DLSP were transformed into rotation-invariant Zernike moments (ZMs), which are particularly suitable for analyses of pattern symmetry. Then we used ZMs, summed intensities, and root mean square contrast as inputs to the advanced Machine Learning methods. We created one random forests classifier for predicting prism orientation, 133 orientation-specific (OS) support vector classification models for predicting the prism aspect-ratios, 133 OS support vector regression models for estimating prism sizes, and another 133 OS Support Vector Regression (SVR) models for estimating the size PADs. We have achieved a high accuracy of 0.99 in predicting prism aspect ratios, and a low value of normalized mean square error of 0.004 for estimating the particle's size and size PADs.
Vertical gaze angle: absolute height-in-scene information for the programming of prehension.
Gardner, P L; Mon-Williams, M
2001-02-01
One possible source of information regarding the distance of a fixated target is provided by the height of the object within the visual scene. It is accepted that this cue can provide ordinal information, but generally it has been assumed that the nervous system cannot extract "absolute" information from height-in-scene. In order to use height-in-scene, the nervous system would need to be sensitive to ocular position with respect to the head and to head orientation with respect to the shoulders (i.e. vertical gaze angle or VGA). We used a perturbation technique to establish whether the nervous system uses vertical gaze angle as a distance cue. Vertical gaze angle was perturbed using ophthalmic prisms with the base oriented either up or down. In experiment 1, participants were required to carry out an open-loop pointing task whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. In experiment 2, the participants reached to grasp an object under closed-loop viewing conditions whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. Experiment 1 and 2 provided clear evidence that the human nervous system uses vertical gaze angle as a distance cue. It was found that the weighting attached to VGA decreased with increasing target distance. The weighting attached to VGA was also affected by the discrepancy between the height of the target, as specified by all other distance cues, and the height indicated by the initial estimate of the position of the supporting surface. We conclude by considering the use of height-in-scene information in the perception of surface slant and highlight some of the complexities that must be involved in the computation of environmental layout.
NASA Astrophysics Data System (ADS)
Dowsett, H. J.; Dolan, A. M.; Rowley, D. B.; Moucha, R.; Forte, A. M.; Mitrovica, J. X.; Pound, M. J.; Salzmann, U.; Robinson, M. M.; Chandler, M. A.; Foley, K.; Haywood, A.
2016-12-01
Past Intervals in Earth history provide unique windows into conditions much different than those observed today. We investigated the paleoenvironments of a past warm interval in the mid Piacenzian ( 3 million years ago). The PRISM4 reconstruction contains twelve internally consistent and integrated data sets representing our best synoptic understanding of surface temperature, vegetation, soils, lakes, ice sheets, topography, and bathymetry. Starting points in the generation of our Piacenzian reconstruction are basic geochemical, faunal, floral, soil, cryospheric, topographic, bathymetric, sedimentologic, and stratigraphic data. Marine and terrestral temperature estimates are based upon multiple proxies (including faunal, floral, geochemical, and biomarker analyses). The reconstruction of Piacenzian global vegetation is based on the integration of paleobotanical data and BIOME4 model outputs. Antarctic and Greenland ice sheets are derived from the previous PRISM3 and PLISMIP (Pliocene Ice Sheet Model Intercomparison Project) results, respectively. Paleogeography is based upon an initial ETOPO1 digital elevation model incorporating PRISM4 ice sheets, GIA, and adjustments due to mantle convection. Soils are determined through comparison of sedimentological and stratigraphic data with the BIOME reconstruction. Lakes are determined from stratigraphic and sedimentological data. Sea-level equivalent (+20 m) is estimated from the reduced volume of the PRISM4 ice sheets and is consistent with our PRISM4 paleogeography. While not an analog for future conditions, the PRISM4 conceptual reconstruction provides insights into processes that occurred in the past and can inform us about the future. We will discuss the use of these data as boundary conditions and verification for global climate model simulations of the Pliocene, aimed at improving our understanding of the climate system as we prepare for future changes.
Leykum, Luci K; Lanham, Holly J; Provost, Shannon M; McDaniel, Reuben R; Pugh, Jacqueline
2014-11-26
Our goal is to improve the safety and effectiveness of inpatient care. Rather than focus on improving process of care, we focus on the social structure within physician teams. We have developed the Physician Relationships, Improvising, and Sensemaking (PRISm) intervention to improve the way physician teams round, enabling them to better relate, make sense of their patients' conditions, and improvise in uncertain clinical situations. We are currently studying the impact of PRISm on adverse events and complications in hospitalized patients. This manuscript describes the PRISm intervention. PRISm is a structured communication tool consisting of three components: daily briefings before rounds; use of the Situation, Task, Intent, Concern, and Calibrate (STICC) framework during rounds as part of the discussion of individual patients; and debriefings after rounds. We are implementing the PRISm intervention on eight inpatient medical and surgical physician teams in the South Texas Veterans Health Care System. We are assessing PRISm impact on the way team members relate to each other, round, and discuss patients through pre- and post-implementation observations and surveys. We are also assessing PRISm impact on complications and adverse events. Finally, we are interviewing physicians regarding their experience using the intervention. Our results will allow us to begin to understand the potential impact of interventions designed to improve how providers relate to each other, improvise, and make sense of what is happening as a strategy for improving inpatient care. Our in-depth data collection will enable us to assess how relationships, improvising, and sensemaking influence patient outcomes, potentially through creating shared mental models or enhancing distributed cognition during clinical reasoning. Finally, our results will lay the groundwork for larger implementation studies to improve clinical outcomes through improving how providers, and providers, patients, and caregivers, relate.
PRISM, Volume 6, Number 1, 2016: Women, Peace and Inclusive Security
2016-03-01
Operations. PRISM is a security studies journal chartered to inform members of U.S. Federal agencies, allies, and other partners on complex and...thrown the national security community into disarray. Faced with such diverse challenges, the U.S. and its allies must step up with a response equally...pool? PRISM is not a journal of advocacy, but rather a venue for informed and rational discourse. The Editors’ goal is to further American and
Analysis of transverse field distributions in Porro prism resonators
NASA Astrophysics Data System (ADS)
Litvin, Igor A.; Burger, Liesl; Forbes, Andrew
2007-05-01
A model to describe the transverse field distribution of the output beam from porro prism resonators is proposed. The model allows the prediction of the output transverse field distribution by assuming that the main areas of loss are located at the apexes of the porro prisms. Experimental work on a particular system showed some interested correlations between the time domain behavior of the resonator and the transverse field output. These findings are presented and discussed.
The non-planar single-frequency ring laser with variable output coupling
NASA Astrophysics Data System (ADS)
Wu, Ke-ying; Yang, Su-hui; Wei, Guang-hui
2002-03-01
We put forward a novel non-planar single-frequency ring laser, which consists of a corner cube prism and a specially cut Porro prism made by Nd:YAG crystal. The relative angle between the corner cube and the Porro prism could be adjusted to control the output coupling of the laser resonator and the polarization-state of the output laser. A 1.06 μm single-frequency laser with 1 W output has been obtained.
The Choice of a Laser for Airborne Depth Sounding
1981-09-01
cavity, polariser, Pockels cell and have the same resonator length,. The Porro prisms of the PCCP are replaced by mirrors in the conventional...crossed Porro resonator The operation of this resonator is described in references 6 and 7. It contains two Porro prisms , one at each end of the...p968, March 1980 "Laser Resonator : An Electrooptically Q-Switched Porro Prism Device" Applied Optics, 15, 8, pl942, August 1976 10 11 See, B.A
Affective three-dimensional brain-computer interface created using a prism array-based display
NASA Astrophysics Data System (ADS)
Mun, Sungchul; Park, Min-Chul
2014-12-01
To avoid the vergence-accommodation mismatch and provide a strong sense of presence to users, we applied a prism array-based display when presenting three-dimensional (3-D) objects. Emotional pictures were used as visual stimuli to increase the signal-to-noise ratios of steady-state visually evoked potentials (SSVEPs) because involuntarily motivated selective attention by affective mechanisms can enhance SSVEP amplitudes, thus producing increased interaction efficiency. Ten male and nine female participants voluntarily participated in our experiments. Participants were asked to control objects under three viewing conditions: two-dimension (2-D), stereoscopic 3-D, and prism. The participants performed each condition in a counter-balanced order. One-way repeated measures analysis of variance showed significant increases in the positive predictive values in the prism condition compared to the 2-D and 3-D conditions. Participants' subjective ratings of realness and engagement were also significantly greater in the prism condition than in the 2-D and 3-D conditions, while the ratings for visual fatigue were significantly reduced in the prism condition than in the 3-D condition. The proposed methods are expected to enhance the sense of reality in 3-D space without causing critical visual fatigue. In addition, people who are especially susceptible to stereoscopic 3-D may be able to use the affective brain-computer interface.
Prism adaptation in Parkinson disease: comparing reaching to walking and freezers to non-freezers.
Nemanich, Samuel T; Earhart, Gammon M
2015-08-01
Visuomotor adaptation to gaze-shifting prism glasses requires recalibration of the relationship between sensory input and motor output. Healthy individuals flexibly adapt movement patterns to many external perturbations; however, individuals with cerebellar damage do not adapt movements to the same extent. People with Parkinson disease (PD) adapt normally, but exhibit reduced after-effects, which are negative movement errors following the removal of the prism glasses and are indicative of true spatial realignment. Walking is particularly affected in PD, and many individuals experience freezing of gait (FOG), an episodic interruption in walking, that is thought to have a distinct pathophysiology. Here, we examined how individuals with PD with (PD + FOG) and without (PD - FOG) FOG, along with healthy older adults, adapted both reaching and walking patterns to prism glasses. Participants completed a visually guided reaching and walking task with and without rightward-shifting prism glasses. All groups adapted at similar rates during reaching and during walking. However, overall walking adaptation rates were slower compared to reaching rates. The PD - FOG group showed smaller after-effects, particularly during walking, compared to PD + FOG, independent of adaptation magnitude. While FOG did not appear to affect characteristics of prism adaptation, these results support the idea that the distinct neural processes governing visuomotor adaptation and storage are differentially affected by basal ganglia dysfunction in PD.
Functional Mapping of the Lectin Activity Site on the β-Prism Domain of Vibrio cholerae Cytolysin
Rai, Anand Kumar; Paul, Karan; Chattopadhyay, Kausik
2013-01-01
Vibrio cholerae cytolysin (VCC) is a prominent member in the family of β-barrel pore-forming toxins. It induces lysis of target eukaryotic cells by forming transmembrane oligomeric β-barrel channels. VCC also exhibits prominent lectin-like activity in interacting with β1-galactosyl-terminated glycoconjugates. Apart from the cytolysin domain, VCC harbors two lectin-like domains: the β-Trefoil and the β-Prism domains; however, precise contribution of these domains in the lectin property of VCC is not known. Also, role(s) of these lectin-like domains in the mode of action of VCC remain obscure. In the present study, we show that the β-Prism domain of VCC acts as the structural scaffold to determine the lectin activity of the protein toward β1-galactosyl-terminated glycoconjugates. Toward exploring the physiological implication of the β-Prism domain, we demonstrate that the presence of the β-Prism domain-mediated lectin activity is crucial for an efficient interaction of the toxin toward the target cells. Our results also suggest that such lectin activity may act to regulate the oligomerization ability of the membrane-bound VCC toxin. Based on the data presented here, and also consistent with the existing structural information, we propose a novel mechanism of regulation imposed by the β-Prism domain's lectin activity, implicated in the process of membrane pore formation by VCC. PMID:23209283
Generation of a high-accuracy regional DEM based on ALOS/PRISM imagery of East Antarctica
NASA Astrophysics Data System (ADS)
Shiramizu, Kaoru; Doi, Koichiro; Aoyama, Yuichi
2017-12-01
A digital elevation model (DEM) is used to estimate ice-flow velocities for an ice sheet and glaciers via Differential Interferometric Synthetic Aperture Radar (DInSAR) processing. The accuracy of DInSAR-derived displacement estimates depends upon the accuracy of the DEM. Therefore, we used stereo optical images, obtained with a panchromatic remote-sensing instrument for stereo mapping (PRISM) sensor mounted onboard the Advanced Land Observing Satellite (ALOS), to produce a new DEM ("PRISM-DEM") of part of the coastal region of Lützow-Holm Bay in Dronning Maud Land, East Antarctica. We verified the accuracy of the PRISM-DEM by comparing ellipsoidal heights with those of existing DEMs and values obtained by satellite laser altimetry (ICESat/GLAS) and Global Navigation Satellite System surveying. The accuracy of the PRISM-DEM is estimated to be 2.80 m over ice sheet, 4.86 m over individual glaciers, and 6.63 m over rock outcrops. By comparison, the estimated accuracy of the ASTER-GDEM, widely used in polar regions, is 33.45 m over ice sheet, 14.61 m over glaciers, and 19.95 m over rock outcrops. For displacement measurements made along the radar line-of-sight by DInSAR, in conjunction with ALOS/PALSAR data, the accuracy of the PRISM-DEM and ASTER-GDEM correspond to estimation errors of <6.3 mm and <31.8 mm, respectively.
Spatial effects of shifting prisms on properties of posterior parietal cortex neurons
Karkhanis, Anushree N; Heider, Barbara; Silva, Fabian Muñoz; Siegel, Ralph M
2014-01-01
The posterior parietal cortex contains neurons that respond to visual stimulation and motor behaviour. The objective of the current study was to test short-term adaptation in neurons in macaque area 7a and the dorsal prelunate during visually guided reaching using Fresnel prisms that displaced the visual field. The visual perturbation shifted the eye position and created a mismatch between perceived and actual reach location. Two non-human primates were trained to reach to visual targets before, during and after prism exposure while fixating the reach target in different locations. They were required to reach to the physical location of the reach target and not the perceived, displaced location. While behavioural adaptation to the prisms occurred within a few trials, the majority of neurons responded to the distortion either with substantial changes in spatial eye position tuning or changes in overall firing rate. These changes persisted even after prism removal. The spatial changes were not correlated with the direction of induced prism shift. The transformation of gain fields between conditions was estimated by calculating the translation and rotation in Euler angles. Rotations and translations of the horizontal and vertical spatial components occurred in a systematic manner for the population of neurons suggesting that the posterior parietal cortex retains a constant representation of the visual field remapping between experimental conditions. PMID:24928956
Prism adaptation for spatial neglect after stroke: translational practice gaps.
Barrett, A M; Goedert, Kelly M; Basso, Julia C
2012-10-01
Spatial neglect increases hospital morbidity and costs in around 50% of the 795,000 people per year in the USA who survive stroke, and an urgent need exists to reduce the care burden of this condition. However, effective acute treatment for neglect has been elusive. In this article, we review 48 studies of a treatment of intense neuroscience interest: prism adaptation training. Due to its effects on spatial motor 'aiming', prism adaptation training may act to reduce neglect-related disability. However, research failed, first, to suggest methods to identify the 50-75% of patients who respond to treatment; second, to measure short-term and long-term outcomes in both mechanism-specific and functionally valid ways; third, to confirm treatment utility during the critical first 8 weeks poststroke; and last, to base treatment protocols on systematic dose-response data. Thus, considerable investment in prism adaptation research has not yet touched the fundamentals needed for clinical implementation. We suggest improved standards and better spatial motor models for further research, so as to clarify when, how and for whom prism adaptation should be applied.
Vasilyeva, I V; Shvirev, S L; Arseniev, S B; Zarubina, T V
2013-01-01
The aim of the present study is to assess a possibility and validity of prognostic scales ISS-RTS-TRISS, PRISM, APACHE II and PTS to be used for the automated calculation in decision support when treating children with severe mechanical traumas. The mentioned scales are used in the Hospital Information System (HIS) MEDIALOG. The retrospective study was conducted using clinical and physiological data collected at the admission and during the first 24 hours of hospitalization in 166 patients. Scales PRISM, APACHE II, ISS-RTS-TRISS were used for calculating the severity of injury and for prognosis in death outcomes. Scale PTS was used for evaluating the severity index only. Our research has shown that ISS-RTS-TRISS has excellent discrimination ability, PRISM and APACHE II prognostic scales have acceptable discrimination ability; moreover, they all have significant calibration ability. PTS scale has acceptable discrimination ability. It has been showed that automated calculation scales ISS-RTS-TRISS, PRISM, APACHE II and PTS are useful for assessing outcomes in children with severe mechanical trauma.
A compact and lightweight off-axis lightguide prism in near to eye display
NASA Astrophysics Data System (ADS)
Zhuang, Zhenfeng; Cheng, Qijia; Surman, Phil; Zheng, Yuanjin; Sun, Xiao Wei
2017-06-01
We propose a method to improve the design of an off-axis lightguide configuration for near to eye displays (NED) using freeform optics technology. The advantage of this modified optical system, which includes an organic light-emitting diode (OLED), a doublet lens, an imaging lightguide prism and a compensation prism, is that it increases optical length path, offers a smaller size, as well as avoids the obstructed views, and matches the user's head shape. In this system, the light emitted from the OLED passes through the doublet lens and is refracted/reflected by the imaging lightguide prism, which is used to magnify the image from the microdisplay, while the compensation prism is utilized to correct the light ray shift so that a low-distortion image can be observed in a real-world setting. A NED with a 4 mm diameter exit pupil, 21.5° diagonal full field of view (FoV), 23 mm eye relief, and a size of 33 mm by 9.3 mm by 16 mm is designed. The developed system is compact, lightweight and suitable for entertainment and education application.
Prism adaptation for spatial neglect after stroke: translational practice gaps
Barrett, A. M.; Goedert, Kelly M.; Basso, Julia C.
2012-01-01
Spatial neglect increases hospital morbidity and costs in around 50% of the 795,000 people per year in the USA who survive stroke, and an urgent need exists to reduce the care burden of this condition. However, effective acute treatment for neglect has been elusive. In this article, we review 48 studies of a treatment of intense neuroscience interest: prism adaptation training. Due to its effects on spatial motor ‘aiming’, prism adaptation training may act to reduce neglect-related disability. However, research failed, first, to suggest methods to identify the 50–75% of patients who respond to treatment; second, to measure short-term and long-term outcomes in both mechanism-specific and functionally valid ways; third, to confirm treatment utility during the critical first 8 weeks poststroke; and last, to base treatment protocols on systematic dose–response data. Thus, considerable investment in prism adaptation research has not yet touched the fundamentals needed for clinical implementation. We suggest improved standards and better spatial motor models for further research, so as to clarify when, how and for whom prism adaptation should be applied. PMID:22926312
Aqil, Anwer; Lippeveld, Theo; Hozumi, Dairiku
2009-01-01
The utility and effectiveness of routine health information systems (RHIS) in improving health system performance in developing countries has been questioned. This paper argues that the health system needs internal mechanisms to develop performance targets, track progress, and create and manage knowledge for continuous improvement. Based on documented RHIS weaknesses, we have developed the Performance of Routine Information System Management (PRISM) framework, an innovative approach to design, strengthen and evaluate RHIS. The PRISM framework offers a paradigm shift by putting emphasis on RHIS performance and incorporating the organizational, technical and behavioural determinants of performance. By describing causal pathways of these determinants, the PRISM framework encourages and guides the development of interventions for strengthening or reforming RHIS. Furthermore, it conceptualizes and proposes a methodology for measuring the impact of RHIS on health system performance. Ultimately, the PRISM framework, in spite of its challenges and competing paradigms, proposes a new agenda for building and sustaining information systems, for the promotion of an information culture, and for encouraging accountability in health systems. PMID:19304786
Multi-tip nano-prisms: Controlled growth and emission enhancement properties
NASA Astrophysics Data System (ADS)
Liu, Ming; Meng, Cong; Xue, Zheng-Hong; Xiong, Xiang; Shu, Da-Jun; Peng, Ru-Wen; Wu, Qiang; Hu, Zheng; Wang, Mu
2013-10-01
We report here the experimental observations that the tip topography of ZnO nano-prisms sensitively depends on the percentage of oxygen in the flux of the carrying gas in vapor growth. At a relatively high oxygen concentration, a number of thin filaments can be nucleated atop nano-prisms, forming a unique fish-spear-like multi-tip morphology. The length and density of the “spear tines” depend on the flux of the carrying gas. The field emission properties of the nanorod array with different tip morphology are investigated. The structures with longer and denser spear tines possess lower turn-on electric field and higher electric current density. The cathodoluminescence properties of the ZnO nano-prisms have also been studied. The luminescence related to defects in multi-tip nano-prisms possesses the strongest intensity, and the nanorod without any tine structure possesses the lowest defect luminescence intensity. The intrinsic luminescence of ZnO around 385 nm, however, has the opposite tendency. We suggest that our observation is inspiring in optimizing the emission properties of the nanowire devices.
NASA Astrophysics Data System (ADS)
Kino, Saiko; Omori, Suguru; Matsuura, Yuji
2016-03-01
An attenuated-total-reflection (ATR), mid-infrared spectroscopy system that consists of hollow optical fibers, a trapezoidal multi-reflection ATR prism, and a conventional FT-IR spectrometer has been developed to measure blood glucose levels. Owing to the low transmission loss and high flexibility of the hollow-optical fiber, the system can measure any sites of the human body where blood capillaries are close to the surface of mucosa, such as inner lips. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. The results of in-vivo measurement of human inner lips showed the feasibility of the proposed system, and the measurement errors were within 20%.
Pesticide Registration Information System
PRISM provides an integrated, web portal for all pesticide related data, communications, registrations and transactions for OPP and its stakeholders, partners and customers. PRISM supports Strategic Goal 4 by automating pesticide registration processes.
NASA Technical Reports Server (NTRS)
Mannucci, A. J.; Anderson, D. N.; Abdu, A. M.
1994-01-01
The Parametrized Real-Time Ionosphere Specification Model (PRISM) is a global ionospheric specification model that can incorporate real-time data to compute accurate electron density profiles. Time series of computed and measured data are compared in this paper. This comparison can be used to suggest methods of optimizing the PRISM adjustment algorithm for TEC data obtained at low altitudes.
Portable Diode Pumped Femtosecond Lasers
2007-03-01
second prism of the pair. [14, p.109] . . 41 2.34. GVD as a function of separation, in µm, of two N-SF18 Brewster angle prisms at a wavelength of...crystal showing Brewster angle of 54.6◦. . . . . . . 45 3.3. Index of refraction of LiSAF (blue) and BK7 (red) as a function of wavelength...separation, in µm, of two N-SF18 Brewster angle prisms at a wavelength of 1023 nm. 2.5 Summary The unique aspects of pulsing lasers can seem quite complex
Crystalline embryos at ice-vapor interfaces
NASA Technical Reports Server (NTRS)
Bartley, D. L.
1976-01-01
The nucleation of small monolayer ice-like clusters at the basal and prism ice-vapor interfaces is considered. It is found that the basal surfaces prefer triangular embryos with an orientation that reverses from layer to layer, whereas the most stable clusters on the prism surfaces are rectangular in configuration. At any given saturation ratio, the preferred prism clusters are found to have a critical energy of formation significantly lower than that of the basal clusters, basically because of differences in cluster corner free energies.
Hand-held optical fuel pin scanner
Kirchner, T.L.; Powers, H.G.
1980-12-07
An optical scanner for indicia arranged in a focal plane perpendicular to an optical system including a rotatable dove prism. The dove prism transmits a rotating image to a stationary photodiode array.
Hand-held optical fuel pin scanner
Kirchner, Tommy L.; Powers, Hurshal G.
1987-01-01
An optical scanner for indicia arranged in a focal plane perpendicular to an optical system including a rotatable dove prism. The dove prism transmits a rotating image to a stationary photodiode array.
NASA Astrophysics Data System (ADS)
Contreras-Reyes, Eduardo; Maksymowicz, Andrei; Lange, Dietrich; Grevemeyer, Ingo; Muñoz-Linford, Pamela; Moscoso, Eduardo
2017-11-01
Subduction megathrust earthquakes show complex rupture behaviour and large lateral variations of slip. However, the factors controlling seismic slip are still under debate. Here, we present 2-D velocity-depth tomographic models across four trench-perpendicular wide angle seismic profiles complemented with high resolution bathymetric data in the area of maximum coseismic slip of the Mw 8.8 Maule 2010 megathrust earthquake (central Chile, 34°-36°S). Results show an abrupt lateral velocity gradient in the trench-perpendicular direction (from 5.0 to 6.0 km/s) interpreted as the contact between the accretionary prism and continental framework rock whose superficial expression spatially correlates with the slope-shelf break. The accretionary prism is composed of two bodies: (1) an outer accretionary wedge (5-10 km wide) characterized by low seismic velocities of 1.8-3.0 km/s interpreted as an outer frontal prism of poorly compacted and hydrated sediment, and (2) the middle wedge (∼50 km wide) with velocities of 3.0-5.0 km/s interpreted as a middle prism composed by compacted and lithified sediment. In addition, the maximum average coseismic slip of the 2010 megathrust event is fairly coincident with the region where the accretionary prism and continental slope are widest (50-60 km wide), and the continental slope angle is low (<5°). We observe a similar relation along the rupture area of the largest instrumentally recorded Valdivia 1960 Mw 9.5 megathrust earthquake. For the case of the Maule event, published differential multibeam bathymetric data confirms that coseismic slip must have propagated up to ∼6 km landwards of the deformation front and hence practically the entire base of the middle prism. Sediment dewatering and compaction processes might explain the competent rheology of the middle prism allowing shallow earthquake rupture. In contrast, the outer frontal prism made of poorly consolidated sediment has impeded the rupture up to the deformation front as high resolution seismic reflection and multibeam bathymetric data have not showed evidence for new deformation in the trench region.
3. ELEVATION. FROM SOUTH WITH CANAL PRISM. Canal Road ...
3. ELEVATION. FROM SOUTH WITH CANAL PRISM. - Canal Road Bridge, Canal Road spanning Delaware Canal Diversion, Locks 22 & 23 in Delaware Canal State Park in Williams Township, Raubsville, Northampton County, PA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tillman, Karl A.; Thapa, Rajesh; Knabe, Kevin
2009-12-20
The frequency comb from a prism-based Cr:forsterite laser has been frequency stabilized using intracavity prism insertion and pump power modulation. Absolute frequency measurements of a CW fiber laser stabilized to the P(13) transition of acetylene demonstrate a fractional instability of {approx}2x10{sup -11} at a 1 s gate time, limited by a commercial Global Positioning System (GPS)-disciplined rubidium oscillator. Additionally, absolute frequency measurements made simultaneously using a second frequency comb indicate relative instabilities of 3x10{sup -12} for both combs for a 1 s gate time. Estimations of the carrier-envelope offset frequency linewidth based on relative intensity noise and the response dynamicsmore » of the carrier-envelope offset to pump power changes confirm the observed linewidths.« less
Yu, Channing; Mannan, Aristotle M.; Yvone, Griselda Metta; Ross, Kenneth N.; Zhang, Yan-Ling; Marton, Melissa A.; Taylor, Bradley R.; Crenshaw, Andrew; Gould, Joshua Z.; Tamayo, Pablo; Weir, Barbara A.; Tsherniak, Aviad; Wong, Bang; Garraway, Levi A.; Shamji, Alykhan F.; Palmer, Michelle A.; Foley, Michael A.; Winckler, Wendy; Schreiber, Stuart L.; Kung, Andrew L.; Golub, Todd R.
2016-01-01
Hundreds of genetically characterized cell lines are available for the discovery of genotype-specific cancer vulnerabilities. However, screening large numbers of compounds against large numbers of cell lines is currently impractical, and such experiments are often difficult to control1-4. Here, we report a method called PRISM that allows pooled screening of mixtures of cancer cell lines by labeling each cell line with 24-nucleotide barcodes. PRISM displayed the expected patterns of cell killing seen in conventional (unpooled) assays. In a screen of 102 cell lines across 8,400 compounds, PRISM led to the identification of BRD-7880 as a potent and highly specific inhibitor of aurora kinases B and C. Cell line pools also efficiently formed tumors as xenografts, and PRISM recapitulated the expected pattern of erlotinib sensitivity in vivo. PMID:26928769
NASA Astrophysics Data System (ADS)
Noel, J.; Yadav, R.; Li, G.; Daqaq, M. F.
2018-02-01
Recent trends in distributed sensing networks have generated significant interest in the design of scalable micro-power generators. One such device exploits the galloping oscillations of a prism to harness energy from a moving fluid. Performance of galloping harvester's depends on the flow patterns around the prism, which, in turn, depend on its geometry and the Reynolds number of the flow. In this letter, we demonstrate that the useful range of the galloping instability can be extended by attaching a rigid splitter plate to the rear face of the prism. The plate provides a secondary flow reattachment point, which serves to improve the oscillation amplitude and power output of the generator. Experimental results demonstrate as much as 67% power enhancement for some prism geometries and a significant reduction in the cut-in wind speed of the generator.
NASA Astrophysics Data System (ADS)
Sabitov, L. S.; Kashapov, N. F.; Gilmanshin, I. R.; Strelkov, Yu M.; Khusainov, D. M.
2017-09-01
The development is demountable foundation for support, including separate reinforced concrete blocks in the form of prisms mounted on the surface of the base and pulled together by horizontal strands, and anchor devices for fixing the supports. The reinforced concrete blocks are made in the form of hollow prisms consisting of walls and square bottoms, and the strands are made in the form of bolts that tighten the walls along the top and bottom, while the anchoring devices for fixing the supports are made in the form of anchors on the bottom of the central prism and horizontal spacers between the support and the walls of the prism in its upper part. Numerical studies of the foundation have been carried out and its optimal sizes have been found in the PK Lira SAPR.
Towards a neuro-computational account of prism adaptation.
Petitet, Pierre; O'Reilly, Jill X; O'Shea, Jacinta
2017-12-14
Prism adaptation has a long history as an experimental paradigm used to investigate the functional and neural processes that underlie sensorimotor control. In the neuropsychology literature, prism adaptation behaviour is typically explained by reference to a traditional cognitive psychology framework that distinguishes putative functions, such as 'strategic control' versus 'spatial realignment'. This theoretical framework lacks conceptual clarity, quantitative precision and explanatory power. Here, we advocate for an alternative computational framework that offers several advantages: 1) an algorithmic explanatory account of the computations and operations that drive behaviour; 2) expressed in quantitative mathematical terms; 3) embedded within a principled theoretical framework (Bayesian decision theory, state-space modelling); 4) that offers a means to generate and test quantitative behavioural predictions. This computational framework offers a route towards mechanistic neurocognitive explanations of prism adaptation behaviour. Thus it constitutes a conceptual advance compared to the traditional theoretical framework. In this paper, we illustrate how Bayesian decision theory and state-space models offer principled explanations for a range of behavioural phenomena in the field of prism adaptation (e.g. visual capture, magnitude of visual versus proprioceptive realignment, spontaneous recovery and dynamics of adaptation memory). We argue that this explanatory framework can advance understanding of the functional and neural mechanisms that implement prism adaptation behaviour, by enabling quantitative tests of hypotheses that go beyond merely descriptive mapping claims that 'brain area X is (somehow) involved in psychological process Y'. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Latysh, Natalie E.; Wetherbee, Gregory Alan
2012-01-01
High-elevation regions in the United States lack detailed atmospheric wet-deposition data. The National Atmospheric Deposition Program/National Trends Network (NADP/NTN) measures and reports precipitation amounts and chemical constituent concentration and deposition data for the United States on annual isopleth maps using inverse distance weighted (IDW) interpolation methods. This interpolation for unsampled areas does not account for topographic influences. Therefore, NADP/NTN isopleth maps lack detail and potentially underestimate wet deposition in high-elevation regions. The NADP/NTN wet-deposition maps may be improved using precipitation grids generated by other networks. The Parameter-elevation Regressions on Independent Slopes Model (PRISM) produces digital grids of precipitation estimates from many precipitation-monitoring networks and incorporates influences of topographical and geographical features. Because NADP/NTN ion concentrations do not vary with elevation as much as precipitation depths, PRISM is used with unadjusted NADP/NTN data in this paper to calculate ion wet deposition in complex terrain to yield more accurate and detailed isopleth deposition maps in complex terrain. PRISM precipitation estimates generally exceed NADP/NTN precipitation estimates for coastal and mountainous regions in the western United States. NADP/NTN precipitation estimates generally exceed PRISM precipitation estimates for leeward mountainous regions in Washington, Oregon, and Nevada, where abrupt changes in precipitation depths induced by topography are not depicted by IDW interpolation. PRISM-based deposition estimates for nitrate can exceed NADP/NTN estimates by more than 100% for mountainous regions in the western United States.
Role of a Standardized Prism Under Cover Test in the Assessment of Dissociated Vertical Deviation.
Klaehn, Lindsay D; Hatt, Sarah R; Leske, David A; Holmes, Jonathan M
2018-03-01
Dissociated vertical deviation (DVD) is commonly measured using a prism and alternate cover test (PACT), but some providers use a prism under cover test (PUCT). The aim of this study was to compare a standardized PUCT measurement with a PACT measurement, for assessing the magnitude of DVD. Thirty-six patients with a clinical diagnosis of DVD underwent measurement of the angle of deviation with the PACT, fixing with the habitually fixing eye, and with PUCT, fixing both right and left eyes. The PUCT was standardized, using a 10-second cover for each prism magnitude, until the deviation was neutralized. The magnitude of hyperdeviation by PACT and PUCT was compared for the non-fixing eye, using paired non-parametric tests. The frequency of discrepancies more than 4 prism diopters (PD) between PACT and PUCT was calculated. The magnitude of hyperdeviation was greater when measured with PUCT (range 8PD hypodeviation to 20PD hyperdeviation) vs. PACT (18PD hypodeviation to 25PD hyperdeviation) with a median difference of 4.5PD (range -5PD to 21PD); P < 0.0001. Eighteen (50%) of 36 measurements elicited >4PD hyperdeviation (or >4PD less hypodeviation) by PUCT than by PACT. A standardized 10-second PUCT yields greater values than a prism and alternate cover test in the majority of patients with DVD, providing better quantification of the severity of DVD, which may be important for management decisions.
Latysh, Natalie E; Wetherbee, Gregory Alan
2012-01-01
High-elevation regions in the United States lack detailed atmospheric wet-deposition data. The National Atmospheric Deposition Program/National Trends Network (NADP/NTN) measures and reports precipitation amounts and chemical constituent concentration and deposition data for the United States on annual isopleth maps using inverse distance weighted (IDW) interpolation methods. This interpolation for unsampled areas does not account for topographic influences. Therefore, NADP/NTN isopleth maps lack detail and potentially underestimate wet deposition in high-elevation regions. The NADP/NTN wet-deposition maps may be improved using precipitation grids generated by other networks. The Parameter-elevation Regressions on Independent Slopes Model (PRISM) produces digital grids of precipitation estimates from many precipitation-monitoring networks and incorporates influences of topographical and geographical features. Because NADP/NTN ion concentrations do not vary with elevation as much as precipitation depths, PRISM is used with unadjusted NADP/NTN data in this paper to calculate ion wet deposition in complex terrain to yield more accurate and detailed isopleth deposition maps in complex terrain. PRISM precipitation estimates generally exceed NADP/NTN precipitation estimates for coastal and mountainous regions in the western United States. NADP/NTN precipitation estimates generally exceed PRISM precipitation estimates for leeward mountainous regions in Washington, Oregon, and Nevada, where abrupt changes in precipitation depths induced by topography are not depicted by IDW interpolation. PRISM-based deposition estimates for nitrate can exceed NADP/NTN estimates by more than 100% for mountainous regions in the western United States.
Design of airborne imaging spectrometer based on curved prism
NASA Astrophysics Data System (ADS)
Nie, Yunfeng; Xiangli, Bin; Zhou, Jinsong; Wei, Xiaoxiao
2011-11-01
A novel moderate-resolution imaging spectrometer spreading from visible wavelength to near infrared wavelength range with a spectral resolution of 10 nm, which combines curved prisms with the Offner configuration, is introduced. Compared to conventional imaging spectrometers based on dispersive prism or diffractive grating, this design possesses characteristics of small size, compact structure, low mass as well as little spectral line curve (smile) and spectral band curve (keystone or frown). Besides, the usage of compound curved prisms with two or more different materials can greatly reduce the nonlinearity inevitably brought by prismatic dispersion. The utilization ratio of light radiation is much higher than imaging spectrometer of the same type based on combination of diffractive grating and concentric optics. In this paper, the Seidel aberration theory of curved prism and the optical principles of Offner configuration are illuminated firstly. Then the optical design layout of the spectrometer is presented, and the performance evaluation of this design, including spot diagram and MTF, is analyzed. To step further, several types of telescope matching this system are provided. This work provides an innovational perspective upon optical system design of airborne spectral imagers; therefore, it can offer theoretic guide for imaging spectrometer of the same kind.
Prism adaptation in virtual and natural contexts: Evidence for a flexible adaptive process.
Veilleux, Louis-Nicolas; Proteau, Luc
2015-01-01
Prism exposure when aiming at a visual target in a virtual condition (e.g., when the hand is represented by a video representation) produces no or only small adaptations (after-effects), whereas prism exposure in a natural condition produces large after-effects. Some researchers suggested that this difference may arise from distinct adaptive processes, but other studies suggested a unique process. The present study reconciled these conflicting interpretations. Forty participants were divided into two groups: One group used visual feedback of their hand (natural context), and the other group used computer-generated representational feedback (virtual context). Visual feedback during adaptation was concurrent or terminal. All participants underwent laterally displacing prism perturbation. The results showed that the after-effects were twice as large in the "natural context" than in the "virtual context". No significant differences were observed between the concurrent and terminal feedback conditions. The after-effects generalized to untested targets and workspace. These results suggest that prism adaptation in virtual and natural contexts involves the same process. The smaller after-effects in the virtual context suggest that the depth of adaptation is a function of the degree of convergence between the proprioceptive and visual information that arises from the hand.
Mortality in Code Blue; can APACHE II and PRISM scores be used as markers for prognostication?
Bakan, Nurten; Karaören, Gülşah; Tomruk, Şenay Göksu; Keskin Kayalar, Sinem
2018-03-01
Code blue (CB) is an emergency call system developed to respond to cardiac and respiratory arrest in hospitals. However, in literature, no scoring system has been reported that can predict mortality in CB procedures. In this study, we aimed to investigate the effectiveness of estimated APACHE II and PRISM scores in the prediction of mortality in patients assessed using CB to retrospectively analyze CB calls. We retrospectively examined 1195 patients who were evaluated by the CB team at our hospital between 2009 and 2013. The demographic data of the patients, diagnosis and relevant de-partments, reasons for CB, cardiopulmonary resuscitation duration, mortality calculated from the APACHE II and PRISM scores, and the actual mortality rates were retrospectively record-ed from CB notification forms and the hospital database. In all age groups, there was a significant difference between actual mortality rate and the expected mortality rate as estimated using APACHE II and PRISM scores in CB calls (p<0.05). The actual mortality rate was significantly lower than the expected mortality. APACHE and PRISM scores with the available parameters will not help predict mortality in CB procedures. Therefore, novels scoring systems using different parameters are needed.
Prism adaptation and spatial neglect: the need for dose-finding studies.
Goedert, Kelly M; Zhang, Jeffrey Y; Barrett, A M
2015-01-01
Spatial neglect is a devastating disorder in 50-70% of right-brain stroke survivors, who have problems attending to, or making movements towards, left-sided stimuli, and experience a high risk of chronic dependence. Prism adaptation is a promising treatment for neglect that involves brief, daily visuo-motor training sessions while wearing optical prisms. Its benefits extend to functional behaviors such as dressing, with effects lasting 6 months or longer. Because one to two sessions of prism adaptation induce adaptive changes in both spatial-motor behavior (Fortis et al., 2011) and brain function (Saj et al., 2013), it is possible stroke patients may benefit from treatment periods shorter than the standard, intensive protocol of ten sessions over two weeks-a protocol that is impractical for either US inpatient or outpatient rehabilitation. Demonstrating the effectiveness of a lower dose will maximize the availability of neglect treatment. We present preliminary data suggesting that four to six sessions of prism treatment may induce a large treatment effect, maintained three to four weeks post-treatment. We call for a systematic, randomized clinical trial to establish the minimal effective dose suitable for stroke intervention.
Regional Variation of CH4 and N2 Production Processes in the Deep Aquifers of an Accretionary Prism
Matsushita, Makoto; Ishikawa, Shugo; Nagai, Kazushige; Hirata, Yuichiro; Ozawa, Kunio; Mitsunobu, Satoshi; Kimura, Hiroyuki
2016-01-01
Accretionary prisms are mainly composed of ancient marine sediment scraped from the subducting oceanic plate at a convergent plate boundary. Large amounts of anaerobic groundwater and natural gas, mainly methane (CH4) and nitrogen gas (N2), are present in the deep aquifers associated with an accretionary prism; however, the origins of these gases are poorly understood. We herein revealed regional variations in CH4 and N2 production processes in deep aquifers in the accretionary prism in Southwest Japan, known as the Shimanto Belt. Stable carbon isotopic and microbiological analyses suggested that CH4 is produced through the non-biological thermal decomposition of organic matter in the deep aquifers in the coastal area near the convergent plate boundary, whereas a syntrophic consortium of hydrogen (H2)-producing fermentative bacteria and H2-utilizing methanogens contributes to the significant production of CH4 observed in deep aquifers in midland and mountainous areas associated with the accretionary prism. Our results also demonstrated that N2 production through the anaerobic oxidation of organic matter by denitrifying bacteria is particularly prevalent in deep aquifers in mountainous areas in which groundwater is affected by rainfall. PMID:27592518
Bowers, Alex R.; Tant, Mark; Peli, Eli
2012-01-01
Aims. Homonymous hemianopia (HH), a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind) side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68) completed road tests with sham oblique prism glasses (SP) and real oblique prism glasses (RP). A masked evaluator rated driving performance along the 25 km routes on busy streets in Ghent, Belgium. Results. The proportion of satisfactory responses to unexpected hazards on the blind side was higher in the RP than the SP drive (80% versus 30%; P = 0.001), but similar for unexpected hazards on the seeing side. Conclusions. These pilot data suggest that oblique peripheral prisms may improve responses of people with HH to blindside hazards when driving and provide the basis for a future, larger-sample clinical trial. Testing responses to unexpected hazards in areas of heavy vehicle and pedestrian traffic appears promising as a real-world outcome measure for future evaluations of HH rehabilitation interventions aimed at improving detection when driving. PMID:23316415
Prism adaptation and spatial neglect: the need for dose-finding studies
Goedert, Kelly M.; Zhang, Jeffrey Y.; Barrett, A. M.
2015-01-01
Spatial neglect is a devastating disorder in 50–70% of right-brain stroke survivors, who have problems attending to, or making movements towards, left-sided stimuli, and experience a high risk of chronic dependence. Prism adaptation is a promising treatment for neglect that involves brief, daily visuo-motor training sessions while wearing optical prisms. Its benefits extend to functional behaviors such as dressing, with effects lasting 6 months or longer. Because one to two sessions of prism adaptation induce adaptive changes in both spatial-motor behavior (Fortis et al., 2011) and brain function (Saj et al., 2013), it is possible stroke patients may benefit from treatment periods shorter than the standard, intensive protocol of ten sessions over two weeks—a protocol that is impractical for either US inpatient or outpatient rehabilitation. Demonstrating the effectiveness of a lower dose will maximize the availability of neglect treatment. We present preliminary data suggesting that four to six sessions of prism treatment may induce a large treatment effect, maintained three to four weeks post-treatment. We call for a systematic, randomized clinical trial to establish the minimal effective dose suitable for stroke intervention. PMID:25983688
Regional Variation of CH4 and N2 Production Processes in the Deep Aquifers of an Accretionary Prism.
Matsushita, Makoto; Ishikawa, Shugo; Nagai, Kazushige; Hirata, Yuichiro; Ozawa, Kunio; Mitsunobu, Satoshi; Kimura, Hiroyuki
2016-09-29
Accretionary prisms are mainly composed of ancient marine sediment scraped from the subducting oceanic plate at a convergent plate boundary. Large amounts of anaerobic groundwater and natural gas, mainly methane (CH4) and nitrogen gas (N2), are present in the deep aquifers associated with an accretionary prism; however, the origins of these gases are poorly understood. We herein revealed regional variations in CH4 and N2 production processes in deep aquifers in the accretionary prism in Southwest Japan, known as the Shimanto Belt. Stable carbon isotopic and microbiological analyses suggested that CH4 is produced through the non-biological thermal decomposition of organic matter in the deep aquifers in the coastal area near the convergent plate boundary, whereas a syntrophic consortium of hydrogen (H2)-producing fermentative bacteria and H2-utilizing methanogens contributes to the significant production of CH4 observed in deep aquifers in midland and mountainous areas associated with the accretionary prism. Our results also demonstrated that N2 production through the anaerobic oxidation of organic matter by denitrifying bacteria is particularly prevalent in deep aquifers in mountainous areas in which groundwater is affected by rainfall.
A Holographic Prism Based on Photo-Thermo-Refractive Glass: Requirements and Possibilities
NASA Astrophysics Data System (ADS)
Angervaks, A. E.; Gorokhovskii, K. S.; Granovskii, V. A.; Van Bac, Doan; Ivanov, S. A.; Okun', R. A.; Nikonorov, N. V.; Ryskin, A. I.
2017-12-01
A technology for multivalued holographic measurement of a plane angle—a holographic prism, which serves as the basis for a device for calibrating the testing tools for navigational equipment under rolling— has been developed. The holographic prism is a miniature sample of photosensitive material, which contains a system of superimposed holographic gratings, and a laser the radiation of which passes through gratings to form a fan of diffracted beams. The fan in a prism based on a calcium fluoride (fluorite) crystal with color centers contained six out-of-plane beams radiating from a region with a hard-to-localize center. This fact hindered calibration of the measure and its application in the testing device. The use of photothermo-refractive glass as a material for preparing a sample and recording a system of holograms in it makes it possible to eliminate the drawbacks of fluorite-based prism. The number of holograms rises up to 21, the fan becomes in-plane, and its center is localized in a small region, with a size of several tenths of the sample thickness (1-2 mm). The fan beams are energetically homogeneous, and each can be identified when using the fan in a testing device.
The optimum content of rubber ash in concrete: flexural strength
NASA Astrophysics Data System (ADS)
Senin, M. S.; Shahidan, S.; Shamsuddin, S. M.; Ariffin, S. F. A.; Othman, N. H.; Rahman, R.; Khalid, F. S.; Nazri, F. M.
2017-11-01
Discarded scrap tyres have become one of the major environmental problems nowadays. Several studies have been carried out to reuse waste tires as an additive or sand replacement in concrete with appropriate percentages of tire rubber, called as rubberized concrete to solve this problem. The main objectives of this study are to investigate the flexural strength performance of concrete when adding the rubber ash and also to analyse the optimum content of rubber ash in concrete prisms. The performance total of 30 number of concrete prisms in size of 100mm x 100mm x 500 mm were investigated, by partially replacement of rubber ash with percentage of 0%, 3%, 5%, 7% and 9% from the volume of the sand. The flexural strength is increased when percentage of rubber ash is added 3% from control concrete prism, RA 0 for both concrete prism age, 7 days and 28 days with value 1.21% and 0.976% respectively. However, for RA 5, RA 7 and RA 9, the flexural strength was decreased compared to the control for both age, 7 days and 28 days. In conclusion, 3% is the optimum content of rubber ash in concrete prism for both concrete age
Optics Near the Snell Angle in a Water-to-Air Change of Medium
2007-01-01
the seawater wedge at the focus of a notional 57.3-mm lens modeled in ZEMAX ® [5]. The boxes are plotted in units of µm, and lens focal length is...lenses had insufficient focal-plane coverage. The ZEMAX spot diagram of this layout is depicted in Fig. 4. It is corrected for the horizon angle...the Fig. 9 ZEMAX layout. It is a two-prism design, but only one prism need be built and carried within the camera, with the forward prism being the
1985-12-01
resonator optics consist of two porro prisms which are oriented 900 from one another about the cavity’s optical axis. In other words, the roof edges of each... prism are perpendicular to one another. The Nd:YAG laser rod measures 5 mm in diameter by 75 mm long and is optically pumped by a Xenon flashlamp. Q...Switching of the laser is performed by a Pockels Cell. A dielectric polarizer is sealed between two right angle prisms which are joined symetrically
Optical Issues in Measuring Strabismus
Irsch, Kristina
2015-01-01
Potential errors and complications during examination and treatment of strabismic patients can be reduced by recognition of certain optical issues. This articles reviews basic as well as guiding principles of prism optics and optics of the eye to equip the reader with the necessary know-how to avoid pitfalls that are commonly encountered when using prisms to measure ocular deviations (e.g., during cover testing), and when observing the corneal light reflex to estimate ocular deviations (e.g., during Hirschberg or Krimsky testing in patients who do not allow for cover testing using prisms). PMID:26180462
Optical Issues in Measuring Strabismus.
Irsch, Kristina
2015-01-01
Potential errors and complications during examination and treatment of strabismic patients can be reduced by recognition of certain optical issues. This articles reviews basic as well as guiding principles of prism optics and optics of the eye to equip the reader with the necessary know-how to avoid pitfalls that are commonly encountered when using prisms to measure ocular deviations (e.g., during cover testing), and when observing the corneal light reflex to estimate ocular deviations (e.g., during Hirschberg or Krimsky testing in patients who do not allow for cover testing using prisms).
Kapoula, Zoi; Gaertner, Chrystal; Matheron, Eric
2012-01-01
There is controversy as to whether dyslexic children present systematic postural deficiency. Clinicians use a combination of ophthalmic prisms and proprioceptive soles to improve postural performances. This study examines the effects of convergent prisms and spherical lenses on posture. Fourteen dyslexics (13–17 years-old) and 11 non dyslexics (13–16 years-old) participated in the study. Quiet stance posturography was performed with the TechnoConcept device while subjects fixated a target at eye-level from a distance of 1_m. Four conditions were run: normal viewing; viewing the target with spherical lenses of −1 diopter (ACCOM1) over each eye; viewing with −3 diopters over each eye (ACCOM3); viewing with a convergent prism of 8 diopters per eye. Relative to normal viewing, the −1 lenses increased the surface of body sway significantly whereas the −3 diopter lenses only resulted in a significant increase of antero-posterior body sway. Thus, adolescents would appear to cope more effectively with stronger conflicts rather than subtle ones. The prism condition resulted in a significant increase in both the surface and the antero-posterior body sway. Importantly, all of these effects were similar for the two groups. Wavelet analysis (time frequency domain) revealed high spectral power of antero-posterior sway for the prism condition in both groups. In the ACCOM3 condition, the spectral power of antero-posterior sway decreased for non dyslexics but increased for dyslexics suggesting that dyslexics encounter more difficulty with accommodation. The cancelling time for medium range frequency (believed to be controlled by the cerebellum), was shorter in dyslexics, suggesting fewer instances of optimal control. We conclude that dyslexics achieve similar postural performances albeit less efficiently. Prisms and lenses destabilize posture for all teenagers. Thus, contrary to adults, adolescents do not seem to use efferent, proprioceptive ocular motor signals to improve their posture, at least not immediately when confronted to convergence accommodation conflict. PMID:23144786
Strategic Planning for Chronic Disease Prevention in Rural America: Looking Through a PRISM Lens.
Honeycutt, Amanda A; Wile, Kristina; Dove, Cassandra; Hawkins, Jackie; Orenstein, Diane
2015-01-01
Community-level strategic planning for chronic disease prevention. To share the outcomes of the strategic planning process used by Mississippi Delta stakeholders to prevent and reduce the negative impacts of chronic disease in their communities. A key component of strategic planning was participants' use of the Prevention Impacts Simulation Model (PRISM) to project the reduction, compared with the status quo, in deaths and costs from implementing interventions in Mississippi Delta communities. Participants in Mississippi Delta strategic planning meetings used PRISM, a user-friendly, evidence-based simulation tool that includes 22 categories of policy, systems, and environmental change interventions, to pose what-if questions that explore the likely short- and long-term effects of an intervention or any desired combination of the 22 categories of chronic disease intervention programs and policies captured in PRISM. These categories address smoking, air pollution, poor nutrition, and lack of physical activity. Strategic planning participants used PRISM outputs to inform their decisions and actions to implement interventions. Rural communities in the Mississippi Delta. A diverse group of 29 to 34 local chronic disease prevention stakeholders, known as the Mississippi Delta Strategic Alliance. Community plans and actions that were developed and implemented as a result of local strategic planning. Existing strategic planning efforts were complemented by the use of PRISM. The Mississippi Delta Strategic Alliance decided to implement new interventions to improve air quality and transportation and to expand existing interventions to reduce tobacco use and increase access to healthy foods. They also collaborated with the Department of Transportation to raise awareness and use of the current transportation network. The Mississippi Delta Strategic Alliance strategic planning process was complemented by the use of PRISM as a tool for strategic planning, which led to the implementation of new and strengthened chronic disease prevention interventions and policies in the Mississippi Delta.
Francese, Joseph A; Rietz, Michael L; Crook, Damon J; Fraser, Ivich; Lance, David R; Mastro, Victor C
2013-12-01
The current emerald ash borer survey trap used in the United States is a prism trap constructed from a stock purple corrugated plastic. In recent years, several colors (particularly shades of green and purple) have been shown to be more attractive to the emerald ash borer than this stock color. Our goal was to determine if plastics produced with these colors and incorporated into prism traps can improve and serve as a new alternative to plastics already in use for the emerald ash borer survey. The plastics were tested in moderate to heavily infested areas in Michigan in two initial studies to test their effectiveness at catching the emerald ash borer. Because results from studies performed in heavily infested sites may not always correspond with what is found along the edges of the infestation, we compared trap catch and detection rates (recording at least one catch on a trap over the course of the entire trapping season) of several trap types and colors at sites outside the core of the currently known emerald ash borer infestation in a nine-state detection tool comparison study. Two of the new plastics, a (Sabic) purple and a medium-dark (Sabic) green were incorporated into prism traps and tested alongside a standard purple prism trap and a green multifunnel trap. In areas with lower emerald ash borer density, the new purple (Sabic) corrugated plastic caught more beetles than the current purple prism trap, as well as more than the medium-dark green (Sabic) prism and green multifunnel traps. Sabic purple traps in the detection tools comparison study recorded a detection rate of 86% compared with 73, 66, and 58% for the standard purple, Sabic green, and green multifunnel traps, respectively. These detection rates were reduced to 80, 63, 55, and 46%, respectively, at low emerald ash borer density sites.
Clinical and Laboratory Evaluation of Peripheral Prism Glasses for Hemianopia
Giorgi, Robert G.; Woods, Russell L.; Peli, Eli
2008-01-01
Purpose Homonymous hemianopia (the loss of vision on the same side in each eye) impairs the ability to navigate and walk safely. We evaluated peripheral prism glasses as a low vision optical device for hemianopia in an extended wearing trial. Methods Twenty-three patients with complete hemianopia (13 right) with neither visual neglect nor cognitive deficit enrolled in the 5-visit study. To expand the horizontal visual field, patients’ spectacles were fitted with both upper and lower Press-On™ Fresnel prism segments (each 40 prism diopters) across the upper and lower portions of the lens on the hemianopic (“blind”) side. Patients were asked to wear these spectacles as much as possible for the duration of the study, which averaged 9 (range: 5 to 13) weeks. Clinical success (continued wear, indicating perceived overall benefit), visual field expansion, perceived direction and perceived quality of life were measured. Results Clinical Success: 14 of 21 (67%) patients chose to continue to wear the peripheral prism glasses at the end of the study (2 patients did not complete the study for non-vision reasons). At long-term follow-up (8 to 51 months), 5 of 12 (42%) patients reported still wearing the device. Visual Field Expansion: Expansion of about 22 degrees in both the upper and lower quadrants was demonstrated for all patients (binocular perimetry, Goldmann V4e). Perceived Direction: Two patients demonstrated a transient adaptation to the change in visual direction produced by the peripheral prism glasses. Quality of Life: At study end, reduced difficulty noticing obstacles on the hemianopic side was reported. Conclusions The peripheral prism glasses provided reported benefits (usually in obstacle avoidance) to 2/3 of the patients completing the study, a very good success rate for a vision rehabilitation device. Possible reasons for long-term discontinuation and limited adaptation of perceived direction are discussed. PMID:19357552
Prisms with total internal reflection as solar reflectors
Rabl, Arnulf; Rabl, Veronika
1978-01-01
An improved reflective wall for radiant energy collection and concentration devices is provided. The wall is comprised of a plurality of prisms whose frontal faces are adjacent and which reflect the desired radiation by total internal reflection.
The PRISM4 (mid-Piacenzian) Palaeoenvironmental Reconstruction
NASA Technical Reports Server (NTRS)
Dowsett, Harry; Dolan, Aisling; Rowley, David; Moucha, Robert; Forte, Alessandro M.; Mitrovica, Jerry X.; Pound, Matthew; Salzmann, Ulrich; Robinson, Marci; Chandler, Mark;
2016-01-01
The mid-Piacenzian is known as a period of relative warmth when compared to the present day. A comprehensive understanding of conditions during the Piacenzian serves as both a conceptual model and a source for boundary conditions as well as means of verification of global climate model experiments. In this paper we present the PRISM4 reconstruction, a paleoenvironmental reconstruction of the mid-Piacenzian (approximately 3 Ma) containing data for paleogeography, land and sea ice, sea-surface temperature, vegetation, soils, and lakes. Our retrodicted paleogeography takes into account glacial isostatic adjustments and changes in dynamic topography. Soils and lakes, both significant as land surface features, are introduced to the PRISM reconstruction for the first time. Sea-surface temperature and vegetation reconstructions are unchanged but now have confidence assessments. The PRISM4 reconstruction is being used as boundary condition data for the Pliocene Model Intercomparison Project Phase 2 (PlioMIP2) experiments.
Ahn, Chi-Yeong; Jang, Segeun; Cho, Yong-Hun; Choi, Jiwoo; Kim, Sungjun; Kim, Sang Moon; Sung, Yung-Eun; Choi, Mansoo
2018-01-19
Guided cracks were successfully generated in an electrode using the concentrated surface stress of a prism-patterned Nafion membrane. An electrode with guided cracks was formed by stretching the catalyst-coated Nafion membrane. The morphological features of the stretched membrane electrode assembly (MEA) were investigated with respect to variation in the prism pattern dimension (prism pitches of 20 μm and 50 μm) and applied strain (S ≈ 0.5 and 1.0). The behaviour of water on the surface of the cracked electrode was examined using environmental scanning electron microscopy. Guided cracks in the electrode layer were shown to be efficient water reservoirs and liquid water passages. The MEAs with and without guided cracks were incorporated into fuel cells, and electrochemical measurements were conducted. As expected, all MEAs with guided cracks exhibited better performance than conventional MEAs, mainly because of the improved water transport.
PRISM project optical instrument
NASA Technical Reports Server (NTRS)
Taylor, Charles R.
1994-01-01
The scientific goal of the Passively-cooled Reconnaissance of the InterStellar Medium (PRISM) project is to map the emission of molecular hydrogen at 17.035 micrometers and 28.221 micrometers. Since the atmosphere is opaque at these infrared wavelengths, an orbiting telescope is being studied. The availability of infrared focal plane arrays enables infrared imaging spectroscopy at the molecular hydrogen wavelengths. The array proposed for PRISM is 128 pixels square, with a pixel size of 75 micrometers. In order to map the sky in a period of six months, and to resolve the nearer molecular clouds, each pixel must cover 0.5 arcminutes. This sets the focal length at 51.6 cm. In order for the pixel size to be half the diameter of the central diffraction peak at 28 micrometers would require a telescope aperture of 24 cm; an aperture of 60 cm has been selected for the PRISM study for greater light gathering power.
Quartz-Enhanced Photoacoustic Spectroscopy with Right-Angle Prism.
Liu, Yongning; Chang, Jun; Lian, Jie; Liu, Zhaojun; Wang, Qiang; Qin, Zengguang
2016-02-06
A right-angle prism was used to enhance the acoustic signal of a quartz-enhanced photoacoustic spectroscopy (QEPAS) system. The incident laser beam was parallelly inverted by the right-angle prism and passed through the gap between two tuning fork prongs again to produce another acoustic excitation. Correspondingly, two pairs of rigid metal tubes were used as acoustic resonators with resonance enhancement factors of 16 and 12, respectively. The QEPAS signal was enhanced by a factor of 22.4 compared with the original signal, which was acquired without resonators or a prism. In addition, the system noise was reduced a little with double resonators due to the Q factor decrease. The signal-to-noise ratio (SNR) was greatly improved. Additionally, a normalized noise equivalent absorption coefficient (NNEA) of 5.8 × 10(-8) W·cm(-1)·Hz(-1/2) was achieved for water vapor detection in the atmosphere.
Adaptive beam tracking and steering via electrowetting-controlled liquid prism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, JT; Chen, CL
2011-11-07
We report an electrowetting-controlled optofluidic system for adaptive beam tracking and agile steering. With two immiscible fluids in a transparent cell, we can actively control the contact angle along the fluid-fluid-solid tri-junction line and hence the orientation of the fluid-fluid interface via electrowetting. The naturally formed meniscus between the two liquids can function as an optical prism. We have fabricated a liquid prism module with an aperture size of 10 mm -10mm. With 1 wt.% KCl and 1 wt.% Sodium Dodecyl Sulfate added into deionized water, the orientation of the water-silicone oil interface has been modulated between -26 degrees andmore » 26 degrees that can deflect and steer beam within the incidence angle of 0 degrees-15 degrees. The wide-range beam tracking and steering enables the liquid prism work as an electrowetting solar cell. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3660578]« less
Adaptive beam tracking and steering via electrowetting-controlled liquid prism
NASA Astrophysics Data System (ADS)
Cheng, Jiangtao; Chen, Chung-Lung
2011-11-01
We report an electrowetting-controlled optofluidic system for adaptive beam tracking and agile steering. With two immiscible fluids in a transparent cell, we can actively control the contact angle along the fluid-fluid-solid tri-junction line and hence the orientation of the fluid-fluid interface via electrowetting. The naturally formed meniscus between the two liquids can function as an optical prism. We have fabricated a liquid prism module with an aperture size of 10 mm × 10mm. With 1 wt. % KCl and 1 wt. % Sodium Dodecyl Sulfate added into deionized water, the orientation of the water-silicone oil interface has been modulated between -26° and 26° that can deflect and steer beam within the incidence angle of 0°-15°. The wide-range beam tracking and steering enables the liquid prism work as an electrowetting solar cell.
[Suicidality in the elderly - what the general practitioner can do].
Haas, Sebastian; Minder, Jacqueline; Harbauer, Gregor
2014-09-03
Suicide rates in Switzerland and most other countries are higher among the elderly than among the population as a whole. Suicidality in the old age is commonly associated with the presence of a mental disorder, especially depression. Medical doctors in primary healthcare have outstanding prominence in detecting suicidal states within elderly patients, because of their common long-standing and confidential relationship and the fact that suicidality is often concealed behind somatisation or other medical complaints. A new practical approach called PRISM-S task enables an assessment of the degree of suicidality in less than five minutes with a simple, visual instrument. Besides the importance of public mental health measures PRISM-S offers a brief, easy-to-administer method for all healthcare professionals to assess suicidality in adult patients (18-65 years). Further investigation will explore its specific usefulness for elderly patients (over 65 years).
The PRISM4 (mid-Piacenzian) paleoenvironmental reconstruction
Dowsett, Harry J.; Dolan, Aisling M.; Rowley, David; Moucha, Robert; Forte, Alessandro; Mitrovica, Jerry X.; Pound, Matthew; Salzmann, Ulrich; Robinson, Marci M.; Chandler, Mark; Foley, Kevin M.; Haywood, Alan M.
2016-01-01
The mid-Piacenzian is known as a period of relative warmth when compared to the present day. A comprehensive understanding of conditions during the Piacenzian serves as both a conceptual model and a source for boundary conditions as well as means of verification of global climate model experiments. In this paper we present the PRISM4 reconstruction, a paleoenvironmental reconstruction of the mid-Piacenzian ( ∼ 3 Ma) containing data for paleogeography, land and sea ice, sea-surface temperature, vegetation, soils, and lakes. Our retrodicted paleogeography takes into account glacial isostatic adjustments and changes in dynamic topography. Soils and lakes, both significant as land surface features, are introduced to the PRISM reconstruction for the first time. Sea-surface temperature and vegetation reconstructions are unchanged but now have confidence assessments. The PRISM4 reconstruction is being used as boundary condition data for the Pliocene Model Intercomparison Project Phase 2 (PlioMIP2) experiments.
Khanfar, H K; Azzam, R M A
2009-09-20
An iterative procedure for the design of a polarizing beam splitter (PBS) that uses a form-birefringent, subwavelength-structured, one-dimensional photonic-crystal layer (SWS 1-D PCL) embedded in a high-index cubical prism is presented. The PBS is based on index matching and total transmission for the p polarization and total internal reflection for the s polarization at the prism-PCL interface at 45 degrees angle of incidence. A high extinction ratio in reflection (>50 dB) over the 4-12 microm IR spectral range is achieved using a SWS 1-D PCL of ZnTe embedded in a ZnS cube within an external field of view of +/-6.6 degrees and in the presence of grating filling factor errors of up to +/-10%. Comparable results, but with wider field of view, are also obtained with a Ge PCL embedded in a Si prism.
Compact, semi-passive beam steering prism array for solar concentrators.
Zheng, Cheng; Li, Qiyuan; Rosengarten, Gary; Hawkes, Evatt; Taylor, Robert A
2017-05-10
In order to maximize solar energy utilization in a limited space (e.g., rooftops), solar collectors should track the sun. As an alternative to rotational tracking systems, this paper presents a compact, semi-passive beam steering prism array which has been designed, analyzed, and tested for solar applications. The proposed prism array enables a linear concentrator system to remain stationary so that it can integrate with a variety of different solar concentrators, and which should be particularly useful for systems which require a low profile (namely rooftop-mounted systems). A case study of this prism array working within a specific rooftop solar collector demonstrates that it can boost the average daily optical efficiency of the collector by 32.7% and expand its effective working time from 6 h to 7.33 h. Overall, the proposed design provides an alternative way to "follow" the sun for a wide range of solar thermal and photovoltaic concentrator systems.
High resolution neutron Larmor diffraction using superconducting magnetic Wollaston prisms
Li, Fankang; Feng, Hao; Thaler, Alexander N.; ...
2017-04-13
The neutron Larmor diffraction technique has been implemented using superconducting magnetic Wollaston prisms in both single-arm and double-arm configurations. Successful measurements of the coefficient of thermal expansion of a single-crystal copper sample demonstrates that the method works as expected. Our experiment involves a new method of tuning by varying the magnetic field configurations in the device and the tuning results agree well with previous measurements. The difference between single-arm and double-arm configurations has been investigated experimentally. Here, we conclude that this measurement benchmarks the applications of magnetic Wollaston prisms in Larmor diffraction and shows in principle that the setup canmore » be used for inelastic phonon line-width measurements. The achievable resolution for Larmor diffraction is comparable to that using Neutron Resonance Spin Echo (NRSE) coils. Furthermore, the use of superconducting materials in the prisms allows high neutron polarization and transmission efficiency to be achieved.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pentz, David L.; Stoll, Ralph H.; Greeves, John T.
2012-07-01
The PRISM (Prioritization Risk Integration Simulation Model), a computer model was developed to support the Department of Energy's Office of Environmental Management (DOE-EM) in its mission to clean up the environmental legacy from the Nation's nuclear weapons materials production complex. PRISM provides a comprehensive, fully integrated planning tool that can tie together DOE-EM's projects. It is designed to help DOE managers develop sound, risk-informed business practices and defend program decisions. It provides a better ability to understand and manage programmatic risks. The underlying concept for PRISM is that DOE-EM 'owns' a portfolio of environmental legacy obligations (ELOs), and that itsmore » mission is to transform the ELOs from their current conditions to acceptable conditions, in the most effective way possible. There are many types of ELOs - - contaminated soils and groundwater plumes, disused facilities awaiting D and D, and various types of wastes waiting for processing or disposal. For a given suite of planned activities, PRISM simulates the outcomes as they play out over time, allowing for all key identified uncertainties and risk factors. Each contaminated building, land area and waste stream is tracked from cradle to grave, and all of the linkages affecting different waste streams are captured. The progression of the activities is fully dynamic, reflecting DOE-EM's prioritization approaches, precedence requirements, available funding, and the consequences of risks and uncertainties. The top level of PRISM is the end-user interface that allows rapid evaluation of alternative scenarios and viewing the results in a variety of useful ways. PRISM is a fully probabilistic model, allowing the user to specify uncertainties in input data (such as the magnitude of an existing groundwater plume, or the total cost to complete a planned activity) as well as specific risk events that might occur. PRISM is based on the GoldSim software that is widely used for risk and performance assessment calculations. PRISM can be run in a deterministic mode, which quickly provides an estimate of the most likely results of a given plan. Alternatively, the model can be run probabilistically in a Monte Carlo mode, exploring the risks and uncertainties in the system and producing probability distributions for the different performance measures. The PRISM model demonstrates how EM can evaluate a portfolio of ELOs, and transform the ELOs from their current conditions to acceptable conditions, utilizing different strategic approaches. There are many types of ELOs - contaminated soils and groundwater plumes, disused facilities awaiting D and D, and various types of wastes waiting for processing or disposal. This scope of work for the PRISM process and the development of a dynamic simulation model are a logical extension of the GoldSim simulation software used by the OCRWM to assess the long-term performance for the Yucca Mountain Project and by NNSA to assess project risk at its sites. Systems integration modeling will promote better understanding of all project risks, technical and nontechnical, and more defensible decision-making for complex projects with significant uncertainties. It can provide effective visual communication and rapid adaptation during interactions with stakeholders (Administration, Congress, State, Local, and NGO). It will also allow rapid assessment of alternative management approaches. (authors)« less
Convergence accommodation to convergence CA/C ratio: convergence versus divergence.
Simmons, Joshua M; Firth, Alison Y
2014-09-01
To determine whether the convergence accommodation to convergence (CA/C) ratio during divergence with base-in (BI) prisms is of a similar or different magnitude to that measured during convergence with base-out (BO) prisms. Eighteen participants with normal binocular single vision were recruited. The participants viewed a pseudo-Gaussian target, which consisted of a light emitting diode (LED) behind a diffusing screen at 40 cm. After 5 minutes of dark adaptation, the refractive status of the eye was measured without any prism using a Shin-Nippon SRW-5000 autorefractor. The participant held the selected prism (5Δ or 10Δ BO or BI, counterbalanced) in front of their right eye and obtained a single, fused image of the target while refractive measures were taken with each. A 30-second rest period was given between measurements. The mean age of the participants was 20.6±3.22 years. The mean CA/C ratios for the 5Δ BO, 10Δ BO, 5Δ BI, and 10Δ BI were 0.108 (±0.074) D/Δ, 0.110 (±0.056) D/Δ, 0.100 (±0.090) D/Δ, and 0.089 (±0.055) D/Δ, respectively. A 2-factor repeated measures ANOVA found that the CA/C ratio did not significantly change with differing levels of prism-induced convergence and divergence (p=0.649). Change in accommodation induced by manipulating vergence is similar whether convergence or divergence are induced. The CA/C ratio did not show any change with differing levels of prism-induced convergence and divergence.
NASA Astrophysics Data System (ADS)
Wu, Lifu; Zhu, Jianguo; Xie, Huimin; Zhou, Mengmeng
2016-12-01
Recently, we proposed a single-lens 3D digital image correlation (3D DIC) method and established a measurement system on the basis of a bilateral telecentric lens (BTL) and a bi-prism. This system can retrieve the 3D morphology of a target and measure its deformation using a single BTL with relatively high accuracy. Nevertheless, the system still suffers from systematic errors caused by manufacturing deficiency of the bi-prism and distortion of the BTL. In this study, in-depth evaluations of these errors and their effects on the measurement results are performed experimentally. The bi-prism deficiency and the BTL distortion are characterized by two in-plane rotation angles and several distortion coefficients, respectively. These values are obtained from a calibration process using a chessboard placed into the field of view of the system; this process is conducted after the measurement of tested specimen. A modified mathematical model is proposed, which takes these systematic errors into account and corrects them during 3D reconstruction. Experiments on retrieving the 3D positions of the chessboard grid corners and the morphology of a ceramic plate specimen are performed. The results of the experiments reveal that ignoring the bi-prism deficiency will induce attitude error to the retrieved morphology, and the BTL distortion can lead to its pseudo out-of-plane deformation. Correcting these problems can further improve the measurement accuracy of the bi-prism-based single-lens 3D DIC system.
Yi-Frazier, Joyce P; Fladeboe, Kaitlyn; Klein, Victoria; Eaton, Lauren; Wharton, Claire; McCauley, Elizabeth; Rosenberg, Abby R
2017-09-01
It is well-known that parental stress and coping impacts the well-being of children with serious illness. The current study aimed to evaluate the feasibility and satisfaction of a novel resilience promoting intervention, the Promoting Resilience in Stress Management Intervention for Parents (PRISM-P) among parents of adolescents and young adults with Type 1 diabetes or cancer. Secondary analyses explored the effect of the PRISM-P on parent-reported resilience and distress. The PRISM-P includes 4 short skills-based modules, delivered in either 2 or 4 separate, individual sessions. English-speaking parents of adolescents with cancer or Type 1 diabetes were eligible. Feasibility was conservatively defined as a completion rate of 80%; satisfaction was qualitatively evaluated based upon parent feedback regarding intervention content, timing, and format. Resilience and distress were assessed pre- and postintervention with the Connor Davidson Resilience Scale and the Kessler-6 Psychological Distress Scale. Twelve of 24 caregivers of youth with diabetes (50%) and 13 of 15 caregivers of youth with cancer (87%) agreed to participate. Nine of 12 (75%) and 9 of 13 (64%) completed all PRISM-P modules, respectively. Among those who completed the intervention, qualitative satisfaction was high. Parent-reported resilience and distress scores improved after the intervention. Effect sizes for both groups indicated a moderate intervention effect. Ultimately, the PRISM-P intervention was well accepted and impactful among parents who completed it. However, attrition rates were higher than anticipated, suggesting alternative or less time-intensive formats may be more feasible. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Czaja, Sara J; Boot, Walter R; Charness, Neil; A Rogers, Wendy; Sharit, Joseph; Fisk, Arthur D; Lee, Chin Chin; Nair, Sankaran N
2015-01-01
Technology holds promise in terms of providing support to older adults. To date, there have been limited robust systematic efforts to evaluate the psychosocial benefits of technology for older people and identify factors that influence both the usability and uptake of technology systems. In response to these issues, we developed the Personal Reminder Information and Social Management System (PRISM), a software application designed for older adults to support social connectivity, memory, knowledge about topics, leisure activities and access to resources. This trail is evaluating the impact of access to the PRISM system on outcomes such as social isolation, social support and connectivity. This paper reports on the approach used to design the PRISM system, study design, methodology and baseline data for the trial. The trial is multi-site randomized field trial. PRISM is being compared to a Binder condition where participants received a binder that contained content similar to that found on PRISM. The sample includes 300 older adults, aged 65-98 years, who lived alone and at risk for being isolated. The primary outcome measures for the trial include indices of social isolation and support and well-being. Secondary outcomes measures include indices of computer proficiency, technology uptake and attitudes towards technology. Follow-up assessments occurred at 6 and 12 months post-randomization. The results of this study will yield important information about the potential value of technology for older adults. The study also demonstrates how a user-centered iterative design approach can be incorporated into the design and evaluation of an intervention protocol. Copyright © 2014 Elsevier Inc. All rights reserved.
Boolean Operations with Prism Algebraic Patches
Bajaj, Chandrajit; Paoluzzi, Alberto; Portuesi, Simone; Lei, Na; Zhao, Wenqi
2009-01-01
In this paper we discuss a symbolic-numeric algorithm for Boolean operations, closed in the algebra of curved polyhedra whose boundary is triangulated with algebraic patches (A-patches). This approach uses a linear polyhedron as a first approximation of both the arguments and the result. On each triangle of a boundary representation of such linear approximation, a piecewise cubic algebraic interpolant is built, using a C1-continuous prism algebraic patch (prism A-patch) that interpolates the three triangle vertices, with given normal vectors. The boundary representation only stores the vertices of the initial triangulation and their external vertex normals. In order to represent also flat and/or sharp local features, the corresponding normal-per-face and/or normal-per-edge may be also given, respectively. The topology is described by storing, for each curved triangle, the two triples of pointers to incident vertices and to adjacent triangles. For each triangle, a scaffolding prism is built, produced by its extreme vertices and normals, which provides a containment volume for the curved interpolating A-patch. When looking for the result of a regularized Boolean operation, the 0-set of a tri-variate polynomial within each such prism is generated, and intersected with the analogous 0-sets of the other curved polyhedron, when two prisms have non-empty intersection. The intersection curves of the boundaries are traced and used to decompose each boundary into the 3 standard classes of subpatches, denoted in, out and on. While tracing the intersection curves, the locally refined triangulation of intersecting patches is produced, and added to the boundary representation. PMID:21516262
Study of dose calculation on breast brachytherapy using prism TPS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fendriani, Yoza; Haryanto, Freddy
2015-09-30
PRISM is one of non-commercial Treatment Planning System (TPS) and is developed at the University of Washington. In Indonesia, many cancer hospitals use expensive commercial TPS. This study aims to investigate Prism TPS which been applied to the dose distribution of brachytherapy by taking into account the effect of source position and inhomogeneities. The results will be applicable for clinical Treatment Planning System. Dose calculation has been implemented for water phantom and CT scan images of breast cancer using point source and line source. This study used point source and line source and divided into two cases. On the firstmore » case, Ir-192 seed source is located at the center of treatment volume. On the second case, the source position is gradually changed. The dose calculation of every case performed on a homogeneous and inhomogeneous phantom with dimension 20 × 20 × 20 cm{sup 3}. The inhomogeneous phantom has inhomogeneities volume 2 × 2 × 2 cm{sup 3}. The results of dose calculations using PRISM TPS were compared to literature data. From the calculation of PRISM TPS, dose rates show good agreement with Plato TPS and other study as published by Ramdhani. No deviations greater than ±4% for all case. Dose calculation in inhomogeneous and homogenous cases show similar result. This results indicate that Prism TPS is good in dose calculation of brachytherapy but not sensitive for inhomogeneities. Thus, the dose calculation parameters developed in this study were found to be applicable for clinical treatment planning of brachytherapy.« less
Czaja, Sara J.; Boot, Walter R.; Charness, Neil; Rogers, Wendy; Sharit, Joseph; Fisk, Arthur D.; Lee, Chin Chin; Nair, Sankaran N.
2014-01-01
Technology holds promise in terms of providing support to older adults. To date there have been limited robust systematic efforts to evaluate the psychosocial benefits of technology for older people and identify factors that influence both the usability and uptake of technology systems. In response to these issues we developed the Personal Reminder Information and Social Management System (PRISM), a software application designed for older adults to support social connectivity, memory, knowledge about topics, leisure activities and access to resources. This trail is evaluating the impact of access to the PRISM system on outcomes such as social isolation, social support and connectivity. This paper reports on the approach used to design the PRISM system, study design, methodology and baseline data for the trial. The trial is multi-site randomized field trial. PRISM is being compared to a Binder condition where participants received a binder that contained content similar to that found on PRISM. The sample includes 300 older adults, aged 65 – 98 years, who lived alone and at risk for being isolated. The primary outcome measures for the trial include indices of social isolation and support and well-being. Secondary outcomes measures include indices of computer proficiency, technology uptake and attitudes towards technology. Follow-up assessments occurred at 6 and 12 months post-randomization. The results of this study will yield important information about the potential value of technology for older adults. The study also demonstrates how a user-centered iterative design approach can be incorporated into the design and evaluation of an intervention protocol. PMID:25460342
NASA Astrophysics Data System (ADS)
Guilyardi, E.
2003-04-01
The European Union's PRISM infrastructure project (PRogram for Integrated earth System Modelling) aims at designing a flexible environment to easily assemble and run Earth System Models (http://prism.enes.org). Europe's widely distributed modelling expertise is both a strength and a challenge. Recognizing this, the PRISM project aims at developing an efficient shared modelling software infrastructure for climate scientists, providing them with an opportunity for greater focus on scientific issues, including the necessary scientific diversity (models and approaches). The proposed PRISM system includes 1) the use - or definition - and promotion of scientific and technical standards to increase component modularity, 2) an end-to-end software environment (coupler, user interface, diagnostics) to launch, monitor and analyze complex Earth System Models built around the existing and future community models, 3) testing and quality standards to ensure HPC performance on a variety of platforms and 4) community wide inputs and requirements capture in all stages of system specifications and design through user/developers meetings, workshops and thematic schools. This science driven project, led by 22 institutes* and started December 1st 2001, benefits from a unique gathering of scientific and technical expertise. More than 30 models (both global and regional) have expressed interest to be part of the PRISM system and 6 types of components have been identified: atmosphere, atmosphere chemistry, land surface, ocean, sea ice and ocean biochemistry. Progress and overall architecture design will be presented. * MPI-Met (Coordinator), KNMI (co-coordinator), MPI-M&D, Met Office, University of Reading, IPSL, Meteo-France, CERFACS, DMI, SMHI, NERSC, ETH Zurich, INGV, MPI-BGC, PIK, ECMWF, UCL-ASTR, NEC, FECIT, SGI, SUN, CCRLE
An in-line optical image translator with applications in x-ray videography.
Picot, P A; Cardinal, H N; Fenster, A
1990-01-01
Many applications in radiography require, or would benefit from, the ability to translate, i.e. move, an optical image in the detector plane. In this paper, we describe the design and characterization of a prism-based optical image translator for insertion into existing XRII-video imaging systems. A pair of prisms rotatable about the optical axis form a very compact in-line optical image translator for installation in the parallel light path between an x-ray image intensifier and its video camera. Rotation of the prisms translates the XRII optical image on the camera target. With the addition of x-ray and light collimators to limit the image to a single video line, x-ray streak images may be acquired. By rotating an object in the x-ray beam during a streak, a complete computed tomography (CT) data set may be acquired. This image translator can translate an image anywhere in the focal plane of a 50-mm-output lens within a 40-mm-diam circle. The prisms have an aperture of 50 mm, permitting an optical speed of F/2 with a 50-mm output lens. The design is insensitive to angular alignment errors. This image translator is achromatic, since the spectral width of the output phosphorus of image intensifiers is sufficient to introduce blurring in a nonacrhomatic design. A prism-based image translator introduces image distortion, since the prisms do not operate at minimum deviation. The distortion is less than 4% over all parts of a typical detector area, and less than 1% in the central region of the image.(ABSTRACT TRUNCATED AT 250 WORDS)
5. VIEW NORTHWEST SHOWING AQUEDUCT PRISM. NOTE INTERIOR STONE WORK ...
5. VIEW NORTHWEST SHOWING AQUEDUCT PRISM. NOTE INTERIOR STONE WORK OF THE PARAPET WALL AND REMAINS OF 1920 TIMBER AND CONCRETE FLOORING SYSTEM. - Chesapeake & Ohio Canal, Conococheague Creek Aqueduct, Milepost 99.80, Williamsport, Washington County, MD
NORTHERLY STRETCH OF MILLBURY PORTION; GENERAL VIEW ACROSS CANAL PRISM ...
NORTHERLY STRETCH OF MILLBURY PORTION; GENERAL VIEW ACROSS CANAL PRISM TO TOWPATH BERM (LATER FILL ENCROACHING LEFT) NEAR CENTER OF THIS STRETCH; VIEW TO SOUTHWEST - Blackstone Canal Worcester-Millbury Segment, Eastern bank of Blackstone River, Millbury, Worcester County, MA
C&O Canal prism, with towpath (left) and fill under WM ...
C&O Canal prism, with towpath (left) and fill under WM roadbed (right), milepost 142 vicinity, looking southwest. - Western Maryland Railway, Cumberland Extension, Pearre to North Branch, from WM milepost 125 to 160, Pearre, Washington County, MD
Generalization of Prism Adaptation
ERIC Educational Resources Information Center
Redding, Gordon M.; Wallace, Benjamin
2006-01-01
Prism exposure produces 2 kinds of adaptive response. Recalibration is ordinary strategic remapping of spatially coded movement commands to rapidly reduce performance error. Realignment is the extraordinary process of transforming spatial maps to bring the origins of coordinate systems into correspondence. Realignment occurs when spatial…
Kirchner, Tommy L.; Powers, Hurshal G.
1983-01-01
An optical scanner for indicia arranged in a focal plane at a cylindrical outside surface by use of an optical system including a rotatable dove prism. The dove prism transmits a rotating image of an encircled cylindrical surface area to a stationary photodiode array.
Why Is White Light Dispersed by a Prism?
ERIC Educational Resources Information Center
Crawford, Frank S.
1979-01-01
Presents the answer to a question, which is intended for high school students, about the dispersion of white light by a glass prism. Why the high frequency waves travel slower than the lower frequencies in glass is also presented. (HM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Qian, Weijun
2013-02-01
Highly sensitive technologies for multiplexed quantification of a large number of candidate proteins will play an increasingly important role in clinical biomarker discovery, systems biology, and general biomedical research. Herein we introduce the new PRISM-SRM technology, which represents a highly sensitive multiplexed quantification technology capable of simultaneous quantification of many low-abundance proteins without the need of affinity reagents. The versatility of antibody-free PRISM-SRM for quantifying various types of targets including protein isoforms, protein modifications, metabolites, and others, thus offering new competition with immunoassays.
Cavity Enhanced Absorption Spectroscopy using a Prism Cavity and Supercontinuum Source
NASA Astrophysics Data System (ADS)
Lehmann, Kevin K.; Johnston, Paul S.
2010-03-01
The multiplex advantage of current cavity enhanced spectrometers is limited by the limited high reflectivity bandwidth of the dielectric mirrors used to construct the high finesse cavity. We report on our development of a spectrometer that uses Brewster's angle retroreflectors that is excited with supercontinuum radiation generated by a 1.06 μm pumped photonic crystal fiber, which covers the 500-1800 nm spectral range. Recent progress will be discussed including modeling of the prism cavity losses, alternative prism materials for use in the UV and mid-IR, and a new higher power source pumped by a mode-locked laser.
Nomura, Kouji; Nakaji-Hirabayashi, Tadashi; Gemmei-Ide, Makoto; Kitano, Hiromi; Noguchi, Hidenori; Uosaki, Kohei
2014-09-01
Surfaces of both a cover glass and the flat plane of a semi-cylindrical quartz prism were modified with a mixture of positively and negatively charged silane coupling reagents (3-aminopropyltriethoxysilane (APTES) and 3-(trihydroxysilyl)propylmethylphosphonate (THPMP), respectively). The glass surface modified with a self-assembled monolayer (SAM) prepared at a mixing ratio of APTES:THPMP=4:6 was electrically almost neutral and was resistant to non-specific adsorption of proteins, whereas fibroblasts gradually adhered to an amphoteric (mixed) SAM surface probably due to its stiffness, though the number of adhered cells was relatively small. Sum frequency generation (SFG) spectra indicated that total intensity of the OH stretching region (3000-3600cm(-1)) for the amphoteric SAM-modified quartz immersed in liquid water was smaller than those for the positively and negatively charged SAM-modified quartz prisms and a bare quartz prism in contact with liquid water. These results suggested that water molecules at the interface of water and an amphoteric SAM-modified quartz prism are not strongly oriented in comparison with those at the interface of a lopsidedly charged SAM-modified quartz prism and bare quartz. The importance of charge neutralization for the anti-biofouling properties of solid materials was strongly suggested. Copyright © 2014 Elsevier B.V. All rights reserved.
Real-time compression of raw computed tomography data: technology, architecture, and benefits
NASA Astrophysics Data System (ADS)
Wegener, Albert; Chandra, Naveen; Ling, Yi; Senzig, Robert; Herfkens, Robert
2009-02-01
Compression of computed tomography (CT) projection samples reduces slip ring and disk drive costs. A lowcomplexity, CT-optimized compression algorithm called Prism CTTM achieves at least 1.59:1 and up to 2.75:1 lossless compression on twenty-six CT projection data sets. We compare the lossless compression performance of Prism CT to alternative lossless coders, including Lempel-Ziv, Golomb-Rice, and Huffman coders using representative CT data sets. Prism CT provides the best mean lossless compression ratio of 1.95:1 on the representative data set. Prism CT compression can be integrated into existing slip rings using a single FPGA. Prism CT decompression operates at 100 Msamp/sec using one core of a dual-core Xeon CPU. We describe a methodology to evaluate the effects of lossy compression on image quality to achieve even higher compression ratios. We conclude that lossless compression of raw CT signals provides significant cost savings and performance improvements for slip rings and disk drive subsystems in all CT machines. Lossy compression should be considered in future CT data acquisition subsystems because it provides even more system benefits above lossless compression while achieving transparent diagnostic image quality. This result is demonstrated on a limited dataset using appropriately selected compression ratios and an experienced radiologist.
Oh, Se-Il; Kim, Jin-Kyung; Park, So-Yeon
2015-12-01
[Purpose] This study aimed to examine the effects of visual field with prism glasses, and intensive upper limb functional training on reduction of hemineglect and improvement in upper limb function and activities of daily living in three stroke patients with hemineglect. [Subjects] This study included three stroke patients hospitalized in a sanatorium. [Methods] Intervention treatment involving prism glass use for 12 hours and 30 minutes and paretic side upper limb training was conducted 5 days a week for 15 weeks. Three upper limb training tasks (hitting a balloon, passing through a ring, and reading a newspaper) were performed for 10 minutes each session, for a total of 30 minutes. Line by Section, Motor-Free Visual Perception Test-3 (MVPT-3), Manual Function Test (MFT), Box & Block Test (BBT), and Assessment of Motor and Process Skills (AMPS) were conducted before and after intervention. [Results] Subjects' hemineglect decreased and upper limb function on the paretic side improved after intervention, which enhanced activities of daily living. [Conclusion] Prism glass use and paretic upper limb functional training effectively ameliorated stroke patients' hemineglect and improved upper limb function. Future research should focus on prism glasses that provide a wide visual field for use in patients with different conditions.
[Prism adaptation test before strabismus surgery : Results of a survey and literature review].
Pichler, U; Rohleder, M; Ehrt, O
2018-02-01
Variable preoperative deviations and compensatory mechanisms may cause wrong dosage of strabismus surgery and result in over- or undercorrection. A long-lasting prism adaptation test (PAT) before surgery is supposed to reduce those difficulties and to improve the postoperative results. To date, the use of prism adaptation before surgery has not been systematically examined. A total of 15 strabismologists and 28 orthoptists in Austria were interviewed about their approach to prism adaptation in 9 types of strabismus. They were also asked about the basis of their decision for a certain treatment regime. Of those interviewed, 28% performed preoperative prism adaptation for weeks to years. Of those, 7% based their decision on evidence from the literature, 54% decide on personal experience, 15% due to guidelines of their institution, and 23% follow the teaching of their medical school. Reports in the literature reveal inconsistent results on PAT. In published studies, PAT was rarely performed longer than 4 weeks and only shows significant improvements on outcome in particular pathologies as acquired esotropia. Long-term PAT appears questionable as to date there is no evidence for a better postoperative outcome. Before setting up guidelines, further controlled, prospective studies on PAT must be conducted.
NASA Astrophysics Data System (ADS)
Leviton, Douglas B.; Miller, Kevin H.; Quijada, Manuel A.; Groff, Tyler D.
2015-09-01
Using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have made the first cryogenic measurements of absolute refractive index for Ohara L-BBH2 glass to enable the design of a prism for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) at the Subaru telescope. L-BBH2 is employed in CHARIS's prism design for improving the spectrograph's dispersion uniformity. Index measurements were made at temperatures from 110 to 305 K at wavelengths from 0.46 to 3.16 μm. We report absolute refractive index (n), dispersion (dn/dλ), and thermo-optic coefficient (dn/dT) for this material along with estimated single measurement uncertainties as a function of wavelength and temperature. We provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures within applicable ranges. This paper also speaks of the challenges in measuring index for a material which is not available in sufficient thickness to fabricate a typical prism for measurement in CHARMS, the tailoring of the index prism design that allowed these index measurements to be made, and the remarkable results obtained from that prism for this practical infrared material.
NASA Astrophysics Data System (ADS)
Manietyev, Leonid; Khoreshok, Aleksey; Tsekhin, Alexander; Borisov, Andrey
2017-11-01
The directions of a resource and energy saving when creating a boom-type effectors of roadheaders of selective action with disc rock cutting tools on a multi-faceted prisms for the destruction of formation of minerals and rocks pricemax are presented. Justified reversing the modes of the crowns and booms to improve the efficiency of mining works. Parameters of destruction of coal and rock faces by the disk tool of a biconical design with the unified fastening knots to many-sided prisms on effectors of extraction mining machines are determined. Parameters of tension of the interfaced elements of knots of fastening of the disk tool at static interaction with the destroyed face of rocks are set. The technical solutions containing the constructive and kinematic communications realizing counter and reverse mode of rotation of two radial crowns with the disk tool on trihedral prisms and cases of booms with the disk tool on tetrahedral prisms in internal space between two axial crowns with the cutter are proposed. Reserves of expansion of the front of loading outside a table of a feeder of the roadheader of selective action, including side zones in which loading corridors by blades of trihedral prisms in internal space between two radial crowns are created are revealed.
NASA Technical Reports Server (NTRS)
Leviton, Douglas B.; Miller, Kevin H.; Quijada, Manuel A.; Groff, Tyler D.
2015-01-01
Using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have made the first cryogenic measurements of absolute refractive index for Ohara L-BBH2 glass to enable the design of a prism for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) at the Subaru telescope. L-BBH2 is employed in CHARIS's prism design for improving the spectrograph's dispersion uniformity. Index measurements were made at temperatures from 110 to 305 K at wavelengths from 0.46 to 3.16 micron. We report absolute refractive index (n), dispersion (dn/d(lambda), and thermo-optic coefficient (dn/dT) for this material along with estimated single measurement uncertainties as a function of wavelength and temperature. We provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures within applicable ranges. This paper also speaks of the challenges in measuring index for a material which is not available in sufficient thickness to fabricate a typical prism for measurement in CHARMS, the tailoring of the index prism design that allowed these index measurements to be made, and the remarkable results obtained from that prism for this practical infrared material.
Numerical simulation of blast wave propagation in vicinity of standalone prism on flat plate
NASA Astrophysics Data System (ADS)
Valger, Svetlana; Fedorova, Natalya; Fedorov, Alexander
2018-03-01
In the paper, numerical simulation of shock wave propagation in the vicinity of a standalone prism and a prism with a cavity in front of it was carried out. The modeling was based on the solution of 3D Euler equations and Fluent software was used as a main computational tool. The algorithm for local dynamic mesh adaptation to high gradients of pressure was applied. The initial stage of the explosion of condensed explosive was described with the help of "Compressed balloon method". The research allowed describing the characteristic stages of the blast in a semi-closed space, the structure of secondary shock waves and their interaction with obstacles. The numerical approach in Fluent based on combining inviscid gas dynamics methods and "Compressed balloon method" was compared with the method which had been used by the authors earlier with the help of AUTODYN and which is based on the use of the hydrodynamic model of a material to describe state of detonation products. For the problem of shock wave propagation in the vicinity of standalone prism the comparison of the simulation results obtained using both the methods with the experimental data was performed on the dependence of static pressure and effective momentum on time for the characteristic points located on prism walls.
NASA Astrophysics Data System (ADS)
Deville, E.
2011-12-01
Recent marine geophysical acquisitions and piston-coring allow to better understand the close interactions between the sand-rich Orinoco turbidite system and the compressional structures of the Barbados prism. Because of the morphologic and tectonic control in the east-Caribbean active margin, the Orinoco turbiditic pattern system does not exhibit a classic fan geometry. The sea-floor geometry between the slope of the front of the Barbados prism and the slope of the South-American margin induces the convergence of the turbidite channels toward the abyssal plain, at the front of the accretionary prism. Also, whereas in most passive margins the turbidite systems are organized upstream to downstream as canyon, then channel-levee, then lobes, here, due to the tectonic control, the sedimentary system is organized as channel-levee, then canyons, then channelized lobes. At the edge of the Orinoco platform, the system has multiple sources with several distributaries and downward the channel courses are complex with frequent convergences or divergences that are emphasized by the effects of the undulating seafloor tectonic morphologies associated with active thrust tectonics and mud volcanism. On top of the accretionary prism, turbidite sediments are filling transported piggy-back basins whose timing of sedimentation vs. deformation is complex. Erosion processes are almost absent on the highly subsiding Orinoco platform and in the upper part of the turbidite system. Erosion processes develop mostly between 2000 and 4000 m of water depth, above the compressional structures of the Barbados prism (canyons up to 3 km wide and 300 m deep). In the abyssal plain, turbiditic channels develop on very long distance (> 1000 km) joining the mid-Atlantic channel (sourced mostly by the Amazon), filling several elongated basins corresponding to transform faults (notably the Barracuda Basin), and finally sourcing the Puerto-Rico trench, the deepest morphologic depression of this region. Piston-core surveys have demonstrated that turbidite sediments above the accretionary prism and in the abyssal plain are mostly coarse sandy deposits covered by recent pelagic planktonic-rich sediments, which indicate that sand deposition has slow down during the post-glacial sea level rise. Numerical stratigraphic modeling suggests that during the last glacial event, the main depocenters were located above the tectonic prism and in the abyssal plain, at the front of the prism and that, during the Holocene eustatic rise, a large accommodation space formed on the shelf confining sedimentation mostly on the Orinoco deltaic platform and producing a starvation downstream in the turbidite system. This is in good agreement with the piston coring results which show low deep turbidite sedimentation rates during recent times.
Prism-assembly for dual-band short-wave infrared region line-scan camera
NASA Astrophysics Data System (ADS)
Chassagne, Bruno; de Laulanié, Lucie; Pommiès, Matthieu
2018-02-01
A simple dichroic splitter for dual-band line scanning is described. It comprises prisms elements that enable cheapness of the whole prototype by using only one linear detector. Validity of the design is demonstrated via in-line moisture measurement.
1. GENERAL VIEW, TOWPATH BERM (CENTER) AND CANAL PRISM (LEFT) ...
1. GENERAL VIEW, TOWPATH BERM (CENTER) AND CANAL PRISM (LEFT) SOUTH OF THE SPILLWAY; VIEW TO SOUTH. - Blackstone Canal Millbury Segment, Beginning northwest of State Route 146 & McCracken Road, running along west side of Route 146, Millbury, Worcester County, MA
ERIC Educational Resources Information Center
Waldenstrom, S.; Naqvi, K. Razi
1978-01-01
Proposes an alternative to the classical minimum-deviation method for determining the refractive index of a prism. This new "fixed angle of incidence method" may find applications in research. (Author/GA)
Tetravalent chromium (Cr(4+)) as laser-active ion for tunable solid-state lasers
NASA Technical Reports Server (NTRS)
Seas, A.; Petricevic, V.; Alfano, Robert R.
1993-01-01
Major accomplishments under NASA grant NAG-1-1346 are summarized. (1) numerical modeling of the four mirror astigmatically compensated, Z-fold cavity was performed and several design parameters to be used for the construction of a femtosecond forsterite laser were revealed by simulation. (2) femtosecond pulses from a continuous wave mode-locked chromium doped forsterite laser were generated. The forsterite laser was actively mode-locked using an acousto-optic modulator operating at 78 MHz with two Brewster high dispersion glass prisms for intra-cavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(sub 00) mode with 85 mW of continuous power tunable over 1230-1280 nm. The shortest pulses of 60-fs pulsewidth were measured. (3) Self-mode-locked operation of the Cr:forsterite laser was achieved. Synchronous pumping was used to mode lock the forsterite laser resulting in picosecond pulses, which in turn provided the starting mechanism for self-mode-locking. The pulses generated had an FWHM of 105 fs and were tunable between 1230-1270 nm. (4) Numerical calculations indicated that the pair of SF 14 prisms used in the cavity compensated for quadratic phase but introduced a large cubic phase term. Further calculations of other optical glasses indicated that a pair of SFN 64 prisms can introduce the same amount of quadratic phase as SF 14 prisms but introduce a smaller cubic phase. When the SF 14 prisms were replaced by SFN 64 prisms the pulsewidth was reduced to 50 fs. Great improvement was observed in the stability of the self mode-locked forsterite laser and in the ease of achieving mode locking. Using the same experimental arrangement and a new forsterite crystal with improved FOM the pulse width was reduced to 36 fs.
Fotiou, K; Hofmann, M; Kaufmann, R; Thaci, D
2015-12-01
Psoriasis has a negative impact on patient's' quality of life, which may reflect the physical and psychosocial impact of the disease. However, little is known about the perceived burden of disease. Pictorial Representation of Illness and Self Measure (PRISM), a pictorial tool, was developed to measure this global suffering. Capturing quality of life impairments in psoriasis is an integral part of assessing the overall disease severity and planning effective treatment strategies. To validate Pictorial Representation of Illness and Self Measure (PRISM) in psoriasis patients. An investigator initiated, prospective cohort study was performed in 108 outpatients with psoriasis to validate PRISM as an appropriate tool; Reliability was assessed in a cohort with controlled stable disease, repeated after 1 hour and after a 3-month follow-up phase; Convergent validity determined by correlation against measures of life quality (DLQI) and reported severity of psoriasis (PASI, PGA and BSA) was performed. For PRISM, we found a high reliability for short-term measurements (ICC = 0.98, P < 0.001) and for follow-up assessments at 3 months (ICC = 0.76, P < 0.001). Our investigation showed significant differences between patients with clear to minimal (PGA 0, 1), mild (PGA 2) and moderate-to-severe disease (PGA 3, 4) and significant (P < 0.001) correlation with DLQI, PGA, PASI and BSA (ρ = -0.62, -0.54, -0.44 and -0.39 respectively). PRISM is a highly reliable tool and new approach to assess perceived burden of patients with psoriasis. It is easy to use and we recommend the application as an additional outcome measure in clinical trial settings. © 2015 European Academy of Dermatology and Venereology.
Post-licensure rapid immunization safety monitoring program (PRISM) data characterization.
Baker, Meghan A; Nguyen, Michael; Cole, David V; Lee, Grace M; Lieu, Tracy A
2013-12-30
The Post-Licensure Rapid Immunization Safety Monitoring (PRISM) program is the immunization safety monitoring component of FDA's Mini-Sentinel project, a program to actively monitor the safety of medical products using electronic health information. FDA sought to assess the surveillance capabilities of this large claims-based distributed database for vaccine safety surveillance by characterizing the underlying data. We characterized data available on vaccine exposures in PRISM, estimated how much additional data was gained by matching with select state and local immunization registries, and compared vaccination coverage estimates based on PRISM data with other available data sources. We generated rates of computerized codes representing potential health outcomes relevant to vaccine safety monitoring. Standardized algorithms including ICD-9 codes, number of codes required, exclusion criteria and location of the encounter were used to obtain the background rates. The majority of the vaccines routinely administered to infants, children, adolescents and adults were well captured by claims data. Immunization registry data in up to seven states comprised between 5% and 9% of data for all vaccine categories with the exception of 10% for hepatitis B and 3% and 4% for rotavirus and zoster respectively. Vaccination coverage estimates based on PRISM's computerized data were similar to but lower than coverage estimates from the National Immunization Survey and Healthcare Effectiveness Data and Information Set. For the 25 health outcomes of interest studied, the rates of potential outcomes based on ICD-9 codes were generally higher than rates described in the literature, which are typically clinically confirmed cases. PRISM program's data on vaccine exposures and health outcomes appear complete enough to support robust safety monitoring. Copyright © 2013 Elsevier Ltd. All rights reserved.
Development and validation of PRISM: a survey tool to identify diabetes self-management barriers.
Cox, Elizabeth D; Fritz, Katie A; Hansen, Kristofer W; Brown, Roger L; Rajamanickam, Victoria; Wiles, Kaelyn E; Fate, Bryan H; Young, Henry N; Moreno, Megan A
2014-04-01
Although most children with type 1 diabetes do not achieve optimal glycemic control, no systematic method exists to identify and address self-management barriers. This study develops and validates PRISM (Problem Recognition in Illness Self-Management), a survey-based tool for efficiently identifying self-management barriers experienced by children/adolescents with diabetes and their parents. Adolescents 13 years and older and parents of children 8 years and older visiting for routine diabetes management (n=425) were surveyed about self-management barriers. HbA1c was abstracted from the electronic health record. To develop PRISM, exploratory and confirmatory factor analyses were used. To assess validity, the association of PRISM scores with HbA1c was examined using linear regression. Factor analyses of adolescent and parent data yielded well-fitting models of self-management barriers, reflecting the following domains: (1) Understanding and Organizing Care, (2) Regimen Pain and Bother, (3) Denial of Disease and Consequences, and (4) Healthcare Team, (5) Family, or (6) Peer Interactions. All models exhibited good fit, with χ(2) ratios<2.21, root mean square errors of approximation<0.09, Confirmatory Fit Indices and Tucker-Lewis Indices both >0.92, and weighted root mean square residuals<1.71. Greater PRISM barrier scores were significantly associated with higher HbA1cs. Our findings suggest at least six different domains exist within self-management barriers, nearly all of which are significantly related to HbA1c. PRISM could be used in clinical practice to identify each child and family's unique self-management barriers, allowing existing self-management resources to be tailored to the family's barriers, ultimately improving effectiveness of such services. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Development and Validation of PRISM: A Survey Tool to Identify Diabetes Self-Management Barriers
Cox, Elizabeth D.; Fritz, Katie A.; Hansen, Kristofer W.; Brown, Roger L.; Rajamanickam, Victoria; Wiles, Kaelyn E.; Fate, Bryan H.; Young, Henry N.; Moreno, Megan A.
2014-01-01
Aims Although most children with type 1 diabetes don’t achieve optimal glycemic control, no systematic method exists to identify and address self-management barriers. This study develops and validates PRISM (Problem Recognition in Illness Self-Management), a survey-based tool for efficiently identifying self-management barriers experienced by children/adolescents with diabetes and their parents. Methods Adolescents 13 years and older and parents of children 8 years and older visiting for routine diabetes management (n=425) were surveyed about self-management barriers. HbA1c was abstracted from the electronic health record. To develop PRISM, exploratory and confirmatory factor analyses were used. To assess validity, the association of PRISM scores with HbA1c was examined using linear regression. Results Factor analyses of adolescent and parent data yielded well-fitting models of self-management barriers, reflecting the following domains: 1) Understanding and Organizing Care, 2) Regimen Pain and Bother, 3) Denial of Disease and Consequences, and 4) Healthcare Team, 5) Family, or 6) Peer Interactions. All models exhibited good fit, with X2 ratios<2.21, root mean square errors of approximation<0.09, Confirmatory Fit Indices and Tucker-Lewis Indices both >0.92, and weighted root mean square residuals<1.71. Greater PRISM barrier scores were significantly associated with higher HbA1cs. Conclusions Our findings suggest at least six different domains exist within self-management barriers, nearly all of which are significantly related to HbA1c. PRISM could be used in clinical practice to identify each child and family’s unique self-management barriers, allowing existing self-management resources to be tailored to the family’s barriers, ultimately improving effectiveness of such services. PMID:24552680
Leteurtre, Stéphane; Leclerc, Francis; Wirth, Jessica; Noizet, Odile; Magnenant, Eric; Sadik, Ahmed; Fourier, Catherine; Cremer, Robin
2004-01-01
Introduction Two generic paediatric mortality scoring systems have been validated in the paediatric intensive care unit (PICU). Paediatric RISk of Mortality (PRISM) requires an observation period of 24 hours, and PRISM III measures severity at two time points (at 12 hours and 24 hours) after admission, which represents a limitation for clinical trials that require earlier inclusion. The Paediatric Index of Mortality (PIM) is calculated 1 hour after admission but does not take into account the stabilization period following admission. To avoid these limitations, we chose to conduct assessments 4 hours after PICU admission. The aim of the present study was to validate PRISM, PRISM III and PIM at the time points for which they were developed, and to compare their accuracy in predicting mortality at those times with their accuracy at 4 hours. Methods All children admitted from June 1998 to May 2000 in one tertiary PICU were prospectively included. Data were collected to generate scores and predictions using PRISM, PRISM III and PIM. Results There were 802 consecutive admissions with 80 deaths. For the time points for which the scores were developed, observed and predicted mortality rates were significantly different for the three scores (P < 0.01) whereas all exhibited good discrimination (area under the receiver operating characteristic curve ≥0.83). At 4 hours after admission only the PIM had good calibration (P = 0.44), but all three scores exhibited good discrimination (area under the receiver operating characteristic curve ≥0.82). Conclusions Among the three scores calculated at 4 hours after admission, all had good discriminatory capacity but only the PIM score was well calibrated. Further studies are required before the PIM score at 4 hours can be used as an inclusion criterion in clinical trials. PMID:15312217
Design of a concise Féry-prism hyperspectral imaging system based on multi-configuration
NASA Astrophysics Data System (ADS)
Dong, Wei; Nie, Yun-feng; Zhou, Jin-song
2013-08-01
In order to meet the needs of space borne and airborne hyperspectral imaging system for light weight, simplification and high spatial resolution, a novel design of Féry-prism hyperspectral imaging system based on Zemax multi-configuration method is presented. The novel structure is well arranged by analyzing optical monochromatic aberrations theoretically, and the optical structure of this design is concise. The fundamental of this design is Offner relay configuration, whereas the secondary mirror is replaced by Féry-prism with curved surfaces and a reflective front face. By reflection, the light beam passes through the Féry-prism twice, which promotes spectral resolution and enhances image quality at the same time. The result shows that the system can achieve light weight and simplification, compared to other hyperspectral imaging systems. Composed of merely two spherical mirrors and one achromatized Féry-prism to perform both dispersion and imaging functions, this structure is concise and compact. The average spectral resolution is 6.2nm; The MTFs for 0.45~1.00um spectral range are greater than 0.75, RMSs are less than 2.4um; The maximal smile is less than 10% pixel, while the keystones is less than 2.8% pixel; image quality approximates the diffraction limit. The design result shows that hyperspectral imaging system with one modified Féry-prism substituting the secondary mirror of Offner relay configuration is feasible from the perspective of both theory and practice, and possesses the merits of simple structure, convenient optical alignment, and good image quality, high resolution in space and spectra, adjustable dispersive nonlinearity. The system satisfies the requirements of airborne or space borne hyperspectral imaging system.
Superconducting magnetic Wollaston prism for neutron spin encoding
NASA Astrophysics Data System (ADS)
Li, F.; Parnell, S. R.; Hamilton, W. A.; Maranville, B. B.; Wang, T.; Semerad, R.; Baxter, D. V.; Cremer, J. T.; Pynn, R.
2014-05-01
A magnetic Wollaston prism can spatially split a polarized neutron beam into two beams with different neutron spin states, in a manner analogous to an optical Wollaston prism. Such a Wollaston prism can be used to encode the trajectory of neutrons into the Larmor phase associated with their spin degree of freedom. This encoding can be used for neutron phase-contrast radiography and in spin echo scattering angle measurement (SESAME). In this paper, we show that magnetic Wollaston prisms with highly uniform magnetic fields and low Larmor phase aberration can be constructed to preserve neutron polarization using high temperature superconducting (HTS) materials. The Meissner effect of HTS films is used to confine magnetic fields produced electromagnetically by current-carrying HTS tape wound on suitably shaped soft iron pole pieces. The device is cooled to ˜30 K by a closed cycle refrigerator, eliminating the need to replenish liquid cryogens and greatly simplifying operation and maintenance. A HTS film ensures that the magnetic field transition within the prism is sharp, well-defined, and planar due to the Meissner effect. The spin transport efficiency across the device was measured to be ˜98.5% independent of neutron wavelength and energizing current. The position-dependent Larmor phase of neutron spins was measured at the NIST Center for Neutron Research facility and found to agree well with detailed simulations. The phase varies linearly with horizontal position, as required, and the neutron beam shows little depolarization. Consequently, the device has advantages over existing devices with similar functionality and provides the capability for a large neutron beam (20 mm × 30 mm) and an increase in length scales accessible to SESAME to beyond 10 μm. With further improvements of the external coupling guide field in the prototype device, a larger neutron beam could be employed.
Gielissen, Marieke F M; Prins, Judith B; Knoop, Hans; Verhagen, Stans; Bleijenberg, Gijs
2013-06-01
The Pictorial Representation of Self and Illness Measure (PRISM) measures in a simple, graphic way the burden of suffering due to illness. The question addressed in this study is whether the PRISM is a valid instrument to measure suffering in cancer survivors experiencing severe fatigue. Quantitative and qualitative data of a previous randomized controlled trial demonstrating the efficacy of cognitive behavior therapy (CBT) especially designed for postcancer fatigue was used to assess convergent validity and sensitivity to change in a sample of 83 cancer survivors. The PRISM, yielding self-illness separation (SIS-fatigue = suffering due to fatigue; SIS-cancer = suffering due to cancer), fatigue severity (Checklist Individual Strength; CIS-fatigue), functional impairment, psychological well-being, quality of life, and coping with the experience of cancer (Impact of Event Scale; IES). Moderate significant correlations were found with the PRISM and the above-mentioned measures. On the basis of SIS scores, the sample was divided into two separate groups: cancer survivors who suffered more because of fatigue and cancer survivors who suffered more because they had cancer in the past. The two groups had different scores on CIS-fatigue and IES, in line with that aspect that caused them the most suffering. The qualitative data confirmed this finding. Participants in the CBT condition demonstrated a significant difference between SIS-fatigue at baseline versus 6 months later compared with those in the waiting list condition. No change of SIS-cancer was found. The PRISM seems to be a valuable tool in fatigue research and clinical practice. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Illusory Reversal of Causality between Touch and Vision has No Effect on Prism Adaptation Rate.
Tanaka, Hirokazu; Homma, Kazuhiro; Imamizu, Hiroshi
2012-01-01
Learning, according to Oxford Dictionary, is "to gain knowledge or skill by studying, from experience, from being taught, etc." In order to learn from experience, the central nervous system has to decide what action leads to what consequence, and temporal perception plays a critical role in determining the causality between actions and consequences. In motor adaptation, causality between action and consequence is implicitly assumed so that a subject adapts to a new environment based on the consequence caused by her action. Adaptation to visual displacement induced by prisms is a prime example; the visual error signal associated with the motor output contributes to the recovery of accurate reaching, and a delayed feedback of visual error can decrease the adaptation rate. Subjective feeling of temporal order of action and consequence, however, can be modified or even reversed when her sense of simultaneity is manipulated with an artificially delayed feedback. Our previous study (Tanaka et al., 2011; Exp. Brain Res.) demonstrated that the rate of prism adaptation was unaffected when the subjective delay of visual feedback was shortened. This study asked whether subjects could adapt to prism adaptation and whether the rate of prism adaptation was affected when the subjective temporal order was illusory reversed. Adapting to additional 100 ms delay and its sudden removal caused a positive shift of point of simultaneity in a temporal order judgment experiment, indicating an illusory reversal of action and consequence. We found that, even in this case, the subjects were able to adapt to prism displacement with the learning rate that was statistically indistinguishable to that without temporal adaptation. This result provides further evidence to the dissociation between conscious temporal perception and motor adaptation.
Superconducting magnetic Wollaston prism for neutron spin encoding.
Li, F; Parnell, S R; Hamilton, W A; Maranville, B B; Wang, T; Semerad, R; Baxter, D V; Cremer, J T; Pynn, R
2014-05-01
A magnetic Wollaston prism can spatially split a polarized neutron beam into two beams with different neutron spin states, in a manner analogous to an optical Wollaston prism. Such a Wollaston prism can be used to encode the trajectory of neutrons into the Larmor phase associated with their spin degree of freedom. This encoding can be used for neutron phase-contrast radiography and in spin echo scattering angle measurement (SESAME). In this paper, we show that magnetic Wollaston prisms with highly uniform magnetic fields and low Larmor phase aberration can be constructed to preserve neutron polarization using high temperature superconducting (HTS) materials. The Meissner effect of HTS films is used to confine magnetic fields produced electromagnetically by current-carrying HTS tape wound on suitably shaped soft iron pole pieces. The device is cooled to ~30 K by a closed cycle refrigerator, eliminating the need to replenish liquid cryogens and greatly simplifying operation and maintenance. A HTS film ensures that the magnetic field transition within the prism is sharp, well-defined, and planar due to the Meissner effect. The spin transport efficiency across the device was measured to be ~98.5% independent of neutron wavelength and energizing current. The position-dependent Larmor phase of neutron spins was measured at the NIST Center for Neutron Research facility and found to agree well with detailed simulations. The phase varies linearly with horizontal position, as required, and the neutron beam shows little depolarization. Consequently, the device has advantages over existing devices with similar functionality and provides the capability for a large neutron beam (20 mm × 30 mm) and an increase in length scales accessible to SESAME to beyond 10 μm. With further improvements of the external coupling guide field in the prototype device, a larger neutron beam could be employed.
Gulick, S.P.S.; Meltzer, A.M.; Clarke, S.H.
1998-01-01
Four multichannel-seismic reflection profiles, collected as part of the Mendocino triple junction seismic experiment, image the toe of the southern Cascadia accretionary prism. Today, 250-600 m of sediment is subducting with the Gorda plate, and 1500-3200 m is accreting to the northern California margin. Faults imaged west and east of the deformation front show mixed structural vergence. A north-south trending, 20 km long portion of the central margin is landward vergent for the outer 6-8 km of the toe of the prism. This region of landward vergence exhibits no frontal thrust, is unusually steep and narrow, and is likely caused by a seaward-dipping backstop close to the deformation front. The lack of margin-wide preferred seaward vergence and wedge-taper analysis suggests the prism has low basal shear stress. The three southern lines image wedge-shaped fragments of oceanic crust 1.1-7.3 km in width and 250-700 m thick near the deformation front. These wedges suggest shortening and thickening of the upper oceanic crust. Discontinuities in the seafloor west of the prism provide evidence for mass wasting in the form of slump blocks and debris fans. The southernmost profile extends 75 km west of the prism imaging numerous faults that offset both the Gorda basin oceanic crust and overlying sediments. These high-angle faults, bounding basement highs, are interpreted as strike-slip faults reactivating structures originally formed at the spreading ridge. Northeast or northwest trending strike-slip faults within the basin are consistent with published focal mechanism solutions and are likely caused by north-south Gorda-Pacific plate convergence. Copyright 1998 by the American Geophysical Union.
ERIC Educational Resources Information Center
Thorson, Jon C.
1972-01-01
The article discusses the design, application, and clinical uses of press-on optics which are descirbed as 1 millimeter thick, flexible lenses or prisms that may be produced in virtually any desired plus or minus dioptric power as ophthalmic lenses, or in any range of usable prism diopter power. (GW)
DOT National Transportation Integrated Search
2013-10-01
The research has been conducted on laboratory-cast concrete prism specimens containing both fine and coarse aggregates obtained from different sources to provide a spectrum of reactivity for assessment through the developed NIRAS technique. The NIRAS...
Budding Architects: Exploring the Designs of Pyramids and Prisms
ERIC Educational Resources Information Center
Leavy, Aisling; Hourigan, Mairéad
2015-01-01
The context of students as architects is used to examine the similarities and differences between prisms and pyramids. Leavy and Hourigan use the Van Hiele Model as a tool to support teachers to develop expectations for differentiating geometry in the classroom using practical examples.
3. VIEW SOUTH SHOWING AQUEDUCT PRISM. NOTE 1920 TIMBER AND ...
3. VIEW SOUTH SHOWING AQUEDUCT PRISM. NOTE 1920 TIMBER AND CONCRETE FLOORING SYSTEM, CUT STONE FACE OF PARAPET WALL, AND WROUGHT IRON BOLTS USED TO SECURE THE RUBBING RAIL. - Chesapeake & Ohio Canal, Conococheague Creek Aqueduct, Milepost 99.80, Williamsport, Washington County, MD
4. VIEW SOUTH SHOWING AQUEDUCT PRISM. NOTE 1920 TIMBER AND ...
4. VIEW SOUTH SHOWING AQUEDUCT PRISM. NOTE 1920 TIMBER AND CONCRETE FLOORING SYSTEM, POCKETS FOR VERTICAL POSTS AND BRIDGING, STEEL BRACES ADDED BY THE NATIONAL PARK SERVICE CIRCA 1962. - Chesapeake & Ohio Canal, Conococheague Creek Aqueduct, Milepost 99.80, Williamsport, Washington County, MD
Prism Adaptation in Schizophrenia
ERIC Educational Resources Information Center
Bigelow, Nirav O.; Turner, Beth M.; Andreasen, Nancy C.; Paulsen, Jane S.; O'Leary, Daniel S.; Ho, Beng-Choon
2006-01-01
The prism adaptation test examines procedural learning (PL) in which performance facilitation occurs with practice on tasks without the need for conscious awareness. Dynamic interactions between frontostriatal cortices, basal ganglia, and the cerebellum have been shown to play key roles in PL. Disruptions within these neural networks have also…
The Determination of the Concentrations of Sugar Solutions by Laser Refractometry.
ERIC Educational Resources Information Center
Hughes, Elvin, Jr.; And Others
1988-01-01
Presents an easily performed experiment to determine sucrose concentrations using a laser and a hollow glass prism. The experiment is suggested for high school, freshman college, and instrumental analysis classes. Notes an Erlenmeyer flask can be used instead of a prism. (MVL)
This dataset represents climate observations throughout the years 2008-09 within individual local NHDPlusV2 catchments and upstream, contributing watersheds based on the Composite Topographic Index (See Supplementary Info for Glossary of Terms). PRISM is a set of monthly, yearly, and single-event gridded data products of mean temperature and precipitation, max/min temperatures, and dewpoints, primarily for the United States. In-situ point measurements are ingested into the PRISM (Parameter elevation Regression on Independent Slopes Model) statistical mapping system. The PRISM products use a weighted regression scheme to account for complex climate regimes associated with orography, rain shadows, temperature inversions, slope aspect, coastal proximity, and other factors. (see Data Sources for links to NHDPlusV2 data and USGS Data) These data were summarized to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).
Structural analysis of β-prism lectin from Colocasia esculenta (L.) S chott.
Vajravijayan, S; Pletnev, S; Pletnev, V Z; Nandhagopal, N; Gunasekaran, K
2016-10-01
The Mannose-binding β-Prism Colocasia esculenta lectin (β-PCL) was purified from tubers using ion exchange chromatography. The purified β-PCL appeared as a single band of ∼12kDa on SDS-PAGE. β-PCL crystallizes in trigonal space group P3121 and diffracted to a resolution of 2.1Å. The structure was solved using Molecular replacement using Crocus vernus lectin (PDB: 3MEZ) as a model. From the final refined model to an R-factor of 16.5% and an Rfree of 20.4%, it has been observed that the biological unit consists of two β-Prism domains augmented through C-terminals swap over to form one of faces for each domain. Cα superposition of individual domains of β-PCL with individual domains of other related structures and superposition of whole protein structures were carried out. The higher RMS deviation for the superposition of whole structures suggest that β-prism domains assume different orientation in each structure. Copyright © 2016 Elsevier B.V. All rights reserved.
Kuzu, Guray; Keskin, Ozlem; Nussinov, Ruth; Gursoy, Attila
2016-10-01
The structures of protein assemblies are important for elucidating cellular processes at the molecular level. Three-dimensional electron microscopy (3DEM) is a powerful method to identify the structures of assemblies, especially those that are challenging to study by crystallography. Here, a new approach, PRISM-EM, is reported to computationally generate plausible structural models using a procedure that combines crystallographic structures and density maps obtained from 3DEM. The predictions are validated against seven available structurally different crystallographic complexes. The models display mean deviations in the backbone of <5 Å. PRISM-EM was further tested on different benchmark sets; the accuracy was evaluated with respect to the structure of the complex, and the correlation with EM density maps and interface predictions were evaluated and compared with those obtained using other methods. PRISM-EM was then used to predict the structure of the ternary complex of the HIV-1 envelope glycoprotein trimer, the ligand CD4 and the neutralizing protein m36.
Single-frequency Nd:YAG ring lasers with corner cube prism
NASA Astrophysics Data System (ADS)
Wu, Ke Ying; Yang, Su Hui; Zhao, Chang Ming; Wei, Guang Hui
2000-04-01
Kane and Byer reported the first monolithic non-planar miniature ring lasers in 1985. An intrinsic optical diode enforces unidirectional and hence single-frequency oscillation of this device. It has the advantages of compactness, reliability and high efficiency. We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single- frequency generating. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix. The results of our initial experiment are given in the paper.
Manufacturing and coating of optical components for the EnMAP hyperspectral imager
NASA Astrophysics Data System (ADS)
Schürmann, M.; Gäbler, D.; Schlegel, R.; Schwinde, S.; Peschel, T.; Damm, C.; Jende, R.; Kinast, J.; Müller, S.; Beier, M.; Risse, S.; Sang, B.; Glier, M.; Bittner, H.; Erhard, M.
2016-07-01
The optical system of the hyperspectral imager of the Environmental Mapping and Analysis Program (EnMAP) consists of a three-mirror anastigmat (TMA) and two independent spectrometers working in the VNIR and SWIR spectral range, respectively. The VNIR spectrometer includes a spherical NiP coated Al6061 mirror that has been ultra-precisely diamond turned and finally coated with protected silver as well as four curved fused silica (FS) and flint glass (SF6) prisms, respectively, each with broadband antireflection (AR) coating, while the backs of the two outer prisms are coated with a high-reflective coating. For AR coating, plasma ion assisted deposition (PIAD) has been used; the high-reflective enhanced Ag-coating on the backside has been deposited by magnetron sputtering. The SWIR spectrometer contains four plane and spherical gold-coated mirrors, respectively, and two curved FS prisms with a broadband antireflection coating. Details about the ultra-precise manufacturing of metal mirrors and prisms as well as their coating are presented in this work.
The Buoyancy Approach to U-tube Problems
NASA Astrophysics Data System (ADS)
Binder, P.-M.; Magowan, M. A.
2016-02-01
In this note we unify two physical situations treatable with hydrostatics: an object floating on a denser fluid and an open U-shaped tube with two immiscible fluids. We begin by reviewing the problem of a partially floating uniform, rectangular prism of horizontal area A immersed in a denser fluid, with respective densities ρ1 < ρh for the prism and fluid (the subscripts stand for light and heavy): see Fig. 1. We define three horizontal levels within the solid, y0, y1, and y2, corresponding to the bottom, flotation line, and top of the prism. The buoyant force is ρh (y1 - y0)gA upwards, and the weight of the prism is ρ1 (y2 - y0)gA downwards. By Newton's second law, these two forces balance at equilibrium. After dividing by the common horizontal area, one obtains y/1-y0 y2-y0 =ρ/1 ρh . A detailed derivation can be found for example in Ref. 1, Section 13-7.
Gómez-Moya, Rosinna; Díaz, Rosalinda; Fernandez-Ruiz, Juan
2016-04-01
Different processes are involved during visuomotor learning, including an error-based procedural and a strategy based cognitive mechanism. Our objective was to analyze if the changes in the adaptation or the aftereffect components of visuomotor learning measured across development, reflected different maturation rates of the aforementioned mechanisms. Ninety-five healthy children aged 4-12years and a group of young adults participated in a wedge prism and a dove prism throwing task, which laterally displace or horizontally reverse the visual field respectively. The results show that despite the age-related differences in motor control, all children groups adapted in the error-based wedge prisms condition. However, when removing the prism, small children showed a slower aftereffects extinction rate. On the strategy-based visual reversing task only the older children group reached adult-like levels. These results are consistent with the idea of different mechanisms with asynchronous maturation rates participating during visuomotor learning. Copyright © 2016 Elsevier B.V. All rights reserved.
Barbados: Architecture and implications for accretion
NASA Astrophysics Data System (ADS)
Speed, R. C.; Larue, D. K.
1982-05-01
The island of Barbados exposes the crestal zone of the remarkably broad accretionary prism of the Lesser Antilles foreacrc. The architecture of Barbados is three-tiered: an upper arched cap of Pleistocene reefs that record rapid and differential uplift of the island, an intermediate zone of nappes of mainly abyssal or deep bathyal pelagic rocks, and a basal complex whose lithotypes extend to substantial depth and may be representative of the bulk of the western or inner accretionary prism. The exposed basal complex consists of generally steeply dipping ENE to NE-striking fault-bounded packets which contain rocks of one of three lithic suites: terrigenous (quartzose turbidite and mudstone), debris flow, and hemipelagic (chiefly radiolarite). Present but imcomplete rock dating indicates that the terrigenous and hemipelagic suites and the pelagic rocks of the intermediate zone are age overlapping in Early and Middle Eocene time. Deformation within packets of the basal complex is systematic, pre- or synfault, and indicative of shortening that is generally normal to packet boundaries. A unit of terrigenous materials that probably underwent local resedimentation in the Miocene is recognized in wells, but its relationship to exposed rocks is uncertain. The packet-bounding faults of the basal complex are interpreted to have been primary accretionary surfaces which may have been reactivated by later intraprism movements. Exposed sedimentary rocks of Barbados can be successfully assigned to contemporaneous depositional sites associated with an accretionary prism: terrigenous beds to a trench wedge that was connected to South American sediment sources, debris flow to trench floor or slope basin accumulations of material derived from the lower slope, hemipelagic to Atlantic plain strata, and pelagic rocks of the intermediate zone to deep outer forearc basin sites. The decollement at the base of the intermediate zone is probably due to uplift and arcward motion of the crestal zone of the accretionary prism with respect to the forearc basin during progressive prism growth. Principal uplift of the prism seems to have started, apparently abruptly, in the Miocene. Quaternary uplift of Barbados may be due partly to local diapirism. Paleogene subduction that created the arcward region of the prism probably occurred in a differently configured zone from the present one.
2013-01-01
Background An ageing population increases demand on health and social care. New approaches are needed to shift care from hospital to community and general practice. A predictive risk stratification tool (Prism) has been developed for general practice that estimates risk of an emergency hospital admission in the following year. We present a protocol for the evaluation of Prism. Methods/Design We will undertake a mixed methods progressive cluster-randomised trial. Practices begin as controls, delivering usual care without Prism. Practices will receive Prism and training randomly, and thereafter be able to use Prism with clinical and technical support. We will compare costs, processes of care, satisfaction and patient outcomes at baseline, 6 and 18 months, using routine data and postal questionnaires. We will assess technical performance by comparing predicted against actual emergency admissions. Focus groups and interviews will be undertaken to understand how Prism is perceived and adopted by practitioners and policy makers. We will model data using generalised linear models and survival analysis techniques to determine whether any differences exist between intervention and control groups. We will take account of covariates and explanatory factors. In the economic evaluation we will carry out a cost-effectiveness analysis to examine incremental cost per emergency admission to hospital avoided and will examine costs versus changes in primary and secondary outcomes in a cost-consequence analysis. We will also examine changes in quality of life of patients across the risk spectrum. We will record and transcribe focus groups and interviews and analyse them thematically. We have received full ethical and R&D approvals for the study and Information Governance Review Panel (IGRP) permission for the use of routine data. We will comply with the CONSORT guidelines and will disseminate the findings at national and international conferences and in peer-reviewed journals. Discussion The proposed study will provide information on costs and effects of Prism; how it is used in practice, barriers and facilitators to its implementation; and its perceived value in supporting the management of patients with and at risk of developing chronic conditions. Trial registration Controlled Clinical Trials ISRCTN no. ISRCTN55538212. PMID:24330749
NASA Technical Reports Server (NTRS)
Pishnyak, Oleg; Golovin, Andrii; Kreminskia, Liubov; Pouch, John J.; Miranda, Felix A.; Winker, Bruce K.; Lavrentovich, Oleg D.
2006-01-01
We describe the application of smectic A (SmA) liquid crystals for beam deflection. SmA materials can be used in digital beam deflectors (DBDs) as fillers for passive birefringent prisms. SmA prisms have high birefringence and can be constructed in a variety of shapes, including single prisms and prismatic blazed gratings of different angles and profiles. We address the challenges of uniform alignment of SmA, such as elimination of focal conic domains. Fast rotation of the incident light polarization in DBDs is achieved by an electrically switched 90 twisted nematic (TN) cell.
Anomalous refraction of light colors by a metamaterial prism.
Silveirinha, Mário G
2009-05-15
A prism of glass separates white light into its spectral components in such a manner that colors associated with shorter wavelengths are more refracted than the colors associated with longer wavelengths. Here, we demonstrate that this property is not universal, and that a lossless metamaterial prism with a suitable microstructure may enable a broadband regime of anomalous dispersion, where the spectral components of light are separated in an unconventional way, so that "violet light" is less refracted than "red light." This phenomenon is fundamentally different from conventional anomalous dispersion effects, which are invariably accompanied by significant loss and are typically very narrow band.
Design of an Airborne Portable Remote Imaging Spectrometer (PRISM) for the Coastal Ocean
NASA Technical Reports Server (NTRS)
Mouroulis, P.; vanGorp, B.; Green, R. O.; Cohen, D.; Wilson, D.; Randall, D.; Rodriguez, J.; Polanco, O.; Dierssen, H.; Balasubramanian, K.;
2010-01-01
PRISM is a pushbroom imaging spectrometer currently under development at the Jet Propulsion Laboratory, intended to address the needs of airborne coastal ocean science research. We describe here the instrument design and the technologies that enable it to achieve its distinguishing characteristics. PRISM covers the 350-1050 nm range with a 3.1 nm sampling and a 33(deg) field of view. The design provides for high signal to noise ratio, high uniformity of response, and low polarization sensitivity. The complete instrument also incorporates two additional wavelength bands at 1240 and 1610 nm in a spot radiometer configuration to aid with atmospheric correction.
Design of a high-power Nd:YAG Q-switched laser cavity
NASA Astrophysics Data System (ADS)
Singh, Ikbal; Kumar, Avinash; Nijhawan, O. P.
1995-06-01
An electro-optically Q-switched Nd:YAG laser resonator that uses two end prisms placed orthogonally perpendicular to each other has been designed. This configuration improves the stability of the resonator and does not alter the characteristics of the electro-optical Q switch. The outcoupling ratio of the cavity is optimized by a change in the azimuthal angle of a phase-matched Porro prism placed at one end of the cavity. The prism placed at the other end of the cavity is designed so that it introduces a phase change of Pi , regardless of its orientation and index of refraction, resulting in a more efficient and stable cavity.
Distributions and motions of nearby stars defined by objective prism surveys and Hipparcos data
NASA Technical Reports Server (NTRS)
Hemenway, P. D.; Lee, J. T.; Upgren, A. R.
1997-01-01
Material and objective prism spectral classification work is used to determine the space density distribution of nearby common stars to the limits of objective prism spectral surveys. The aim is to extend the knowledge of the local densities of specific spectral types from a radius of 25 pc from the sun, as limited in the Gliese catalog of nearby stars, to 50 pc or more. Future plans for the application of these results to studies of the kinematic and dynamical properties of stars in the solar neighborhood as a function of their physical properties and ages are described.
Effect of form of obstacle on speed of crowd evacuation
NASA Astrophysics Data System (ADS)
Yano, Ryosuke
2018-03-01
This paper investigates the effect of the form of an obstacle on the time that a crowd takes to evacuate a room, using a toy model. Pedestrians are modeled as active soft matter moving toward a point with intended velocities. An obstacle is placed in front of the exit, and it has one of four shapes: a cylindrical column, a triangular prism, a quadratic prism, or a diamond prism. Numerical results indicate that the evacuation-completion time depends on the shape of the obstacle. Obstacles with a circular cylinder (C.C.) shape yield the shortest evacuation-completion time in the proposed model.
Dong, F.; Yue, G. Q.; Ames Lab. and Iowa State Univ., Ames, IA; ...
2017-03-24
First-principles molecular dynamic (MD) simulation and X-ray diffraction were employed to study the local structures of Pd–Si liquid at the eutectic composition (Pd 82Si 18). Here, a strong repulsion is found between Si atoms, and Si atoms prefer to be evenly distributed in the liquid. The dominate local structures around Si atoms are found to be with of a trigonal prism capped by three half-octahedra and an archimedean anti-prism. The populations of these clusters increase significantly upon cooling, and may play an important role in the formation of Pd 82Si 18 alloy glass.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, F.; Yue, G. Q.; Ames Lab. and Iowa State Univ., Ames, IA
First-principles molecular dynamic (MD) simulation and X-ray diffraction were employed to study the local structures of Pd–Si liquid at the eutectic composition (Pd 82Si 18). Here, a strong repulsion is found between Si atoms, and Si atoms prefer to be evenly distributed in the liquid. The dominate local structures around Si atoms are found to be with of a trigonal prism capped by three half-octahedra and an archimedean anti-prism. The populations of these clusters increase significantly upon cooling, and may play an important role in the formation of Pd 82Si 18 alloy glass.
3. GENERAL VIEW ACROSS CANAL PRISM TO TOWPATH BERM NORTH ...
3. GENERAL VIEW ACROSS CANAL PRISM TO TOWPATH BERM NORTH OF THE SPILLWAY; VIEW TO WEST FROM ROUTE 146 EMBANKMENT. - Blackstone Canal Millbury Segment, Beginning northwest of State Route 146 & McCracken Road, running along west side of Route 146, Millbury, Worcester County, MA
Reflecting Schmidt/Littrow Prism Imaging Spectrometer
NASA Technical Reports Server (NTRS)
Breckinridge, J. B.; Page, N. A.; Shack, R. V.; Shannon, R. R.
1985-01-01
High resolution achieved with wide field of view. Imaging Spectrometer features off-axis reflecting optics, including reflecting "slit" that also serves as field flattener. Only refracting element is prism. By scanning slit across object or scene and timing out signal, both spectral and spatial information in scene are obtained.
2. GENERAL VIEW ACROSS CANAL PRISM TO TOWPATH BERM SOUTH ...
2. GENERAL VIEW ACROSS CANAL PRISM TO TOWPATH BERM SOUTH OF THE SPILLWAY; VIEW TO SOUTHWEST FROM ROUTE 146 EMBANKMENT. - Blackstone Canal Millbury Segment, Beginning northwest of State Route 146 & McCracken Road, running along west side of Route 146, Millbury, Worcester County, MA
Accuracy improvement of the ice flow rate measurements on Antarctic ice sheet by DInSAR method
NASA Astrophysics Data System (ADS)
Shiramizu, Kaoru; Doi, Koichiro; Aoyama, Yuichi
2015-04-01
DInSAR (Differential Interferometric Synthetic Aperture Radar) is an effective tool to measure the flow rate of slow flowing ice streams on Antarctic ice sheet with high resolution. In the flow rate measurement by DInSAR method, we use Digital Elevation Model (DEM) at two times in the estimating process. At first, we use it to remove topographic fringes from InSAR images. And then, it is used to project obtained displacements along Line-Of-Sight (LOS) direction to the actual flow direction. ASTER-GDEM widely-used for InSAR prosessing of the data of polar region has a lot of errors especially in the inland ice sheet area. Thus the errors yield irregular flow rates and directions. Therefore, quality of DEM has a substantial influence on the ice flow rate measurement. In this study, we created a new DEM (resolution 10m; hereinafter referred to as PRISM-DEM) based on ALOS/PRISM images, and compared PRISM-DEM and ASTER-GDEM. The study area is around Skallen, 90km south from Syowa Station, in the southern part of Sôya Coast, East Antarctica. For making DInSAR images, we used ALOS/PALSAR data of 13 pairs (Path633, Row 571-572), observed during the period from November 23, 2007 through January 16, 2011. PRISM-DEM covering the PALSAR scene was created from nadir and backward view images of ALOS/PRISM (Observation date: 2009/1/18) by applying stereo processing with a digital mapping equipment, and then the automatically created a primary DEM was corrected manually to make a final DEM. The number of irregular values of actual ice flow rate was reduced by applying PRISM-DEM compared with that by applying ASTER-GDEM. Additionally, an averaged displacement of approximately 0.5cm was obtained by applying PRISM-DEM over outcrop area, where no crustal displacement considered to occur during the recurrence period of ALOS/PALSAR (46days), while an averaged displacement of approximately 1.65 cm was observed by applying ASTER-GDEM. Since displacements over outcrop area are considered to be apparent ones, the average could be a measure of flow rate estimation accuracy by DInSAR. Therefore, it is concluded that the accuracy of the ice flow rate measurement can be improved by using PRISM-DEM. In this presentation, we will show the results of the estimated flow rate of ice streams in the region of interest, and discuss the additional accuracy improvement of this method.
Propagation of rotational Risley-prism-array-based Gaussian beams in turbulent atmosphere
NASA Astrophysics Data System (ADS)
Chen, Feng; Ma, Haotong; Dong, Li; Ren, Ge; Qi, Bo; Tan, Yufeng
2018-03-01
Limited by the size and weight of prism and optical assembling, Rotational Risley-prism-array system is a simple but effective way to realize high power and superior beam quality of deflecting laser output. In this paper, the propagation of the rotational Risley-prism-array-based Gaussian beam array in atmospheric turbulence is studied in detail. An analytical expression for the average intensity distribution at the receiving plane is derived based on nonparaxial ray tracing method and extended Huygens-Fresnel principle. Power in the diffraction-limited bucket is chosen to evaluate beam quality. The effect of deviation angle, propagation distance and intensity of turbulence on beam quality is studied in detail by quantitative simulation. It reveals that with the propagation distance increasing, the intensity distribution gradually evolves from multiple-petal-like shape into the pattern that contains one main-lobe in the center with multiple side-lobes in weak turbulence. The beam quality of rotational Risley-prism-array-based Gaussian beam array with lower deviation angle is better than its counterpart with higher deviation angle when propagating in weak and medium turbulent (i.e. Cn2 < 10-13m-2/3), the beam quality of higher deviation angle arrays degrades faster as the intensity of turbulence gets stronger. In the case of propagating in strong turbulence, the long propagation distance (i.e. z > 10km ) and deviation angle have no influence on beam quality.
Establishment and correction of an Echelle cross-prism spectrogram reduction model
NASA Astrophysics Data System (ADS)
Zhang, Rui; Bayanheshig; Li, Xiaotian; Cui, Jicheng
2017-11-01
The accuracy of an echelle cross-prism spectrometer depends on the matching degree between the spectrum reduction model and the actual state of the spectrometer. However, the error of adjustment can change the actual state of the spectrometer and result in a reduction model that does not match. This produces an inaccurate wavelength calibration. Therefore, the calibration of a spectrogram reduction model is important for the analysis of any echelle cross-prism spectrometer. In this study, the spectrogram reduction model of an echelle cross-prism spectrometer was established. The image position laws of a spectrometer that varies with the system parameters were simulated to the influence of the changes in prism refractive index, focal length and so on, on the calculation results. The model was divided into different wavebands. The iterative method, least squares principle and element lamps with known characteristic wavelength were used to calibrate the spectral model in different wavebands to obtain the actual values of the system parameters. After correction, the deviation of actual x- and y-coordinates and the coordinates calculated by the model are less than one pixel. The model corrected by this method thus reflects the system parameters in the current spectrometer state and can assist in accurate wavelength extraction. The instrument installation and adjustment would be guided in model-repeated correction, reducing difficulty of equipment, respectively.
Ma, Zhipeng; Shao, Guangjie; Fan, Yuqian; Wang, Guiling; Song, Jianjun; Liu, Tingting
2014-06-25
Olivine LiFePO4 with nanoplate, rectangular prism nanorod and hexagonal prism nanorod morphologies with a short b-axis were successfully synthesized by a solvothermal in glycerol and water system. The influences of solvent composition on the morphological transformation and electrochemical performances of olivine LiFePO4 are systematically investigated by X-ray diffraction, scanning electron microscopy, transmission electron microscopy and galvanostatic charge-discharge tests. It is found that with increasing water content in solvent, the LiFePO4 nanoplates gradually transform into hexagonal prism nanorods that are similar to the thermodynamic equilibrium shape of the LiFePO4 crystal. This indicates that water plays an important role in the morphology transformation of the olivine LiFePO4. The electrochemical performances vary significantly with the particle morphology. The LiFePO4 rectangular prism nanorods (formed in a glycerol-to-water ratio of 1:1) exhibit superior electrochemical properties compared with the other morphological particles because of their moderate size and shorter Li(+) ion diffusion length along the [010] direction. The initial discharge capacity of the LiFePO4@C with a rectangular prism nanorod morphology reaches to 163.8 mAh g(-1) at 0.2 C and over 75 mAh g(-1) at the high discharging rate of 20 C, maintaining good stability at each discharging rate.
Building Double-decker Traps for Early Detection of Emerald Ash Borer.
McCullough, Deborah G; Poland, Therese M
2017-10-04
Emerald ash borer (EAB) (Agrilus planipennis Fairmaire), the most destructive forest insect to have invaded North America, has killed hundreds of millions of forest and landscape ash (Fraxinus spp.) trees. Several artificial trap designs to attract and capture EAB beetles have been developed to detect, delineate, and monitor infestations. Double-decker (DD) traps consist of two corrugated plastic prisms, one green and one purple, attached to a 3 m tall polyvinyl chloride (PVC) pipe supported by a t-post. The green prism at the top of the PVC pipe is baited with cis-3-hexenol, a compound produced by ash foliage. Surfaces of both prisms are coated with sticky insect glue to capture adult EAB beetles. Double-decker traps should be placed near ash trees but in open areas, exposed to sun. Double-decker trap construction and placement are presented here, along with a summary of field experiments demonstrating the efficacy of DD traps in capturing EAB beetles. In a recent study in sites with relatively low EAB densities, double-decker traps captured significantly more EAB than green or purple prism traps or green funnel traps, all of which are designed to be suspended from a branch in the canopy of ash trees. A greater percentage of double decker traps were positive, i.e., captured at least one EAB, than the prism traps or funnel traps that were hung in ash tree canopies.
Padula, William V; Subramanian, Prem; Spurling, April; Jenness, Jonathan
2015-01-01
Following a neurologic event such as traumatic brain injury (TBI), cerebrovascular accident (CVA), and chronic neurological conditions including Parkinson's disease, multiple sclerosis, and cerebral palsy a shift in the visual midline (egocenter) can directly affect posture, balance and spatial orientation. As a consequence, this increases the risk of fall (RoF) and injury that imposes a major financial burden on the public health system. To determine if there is a statistically significant change in balance with the intervention of yoked prisms to reduce the risk of fall in subjects with neurological impairments. Ambulation of thirty-six subjects was evaluated on a pressure sensitive mat before and after intervention with yoked prisms. Changes in gait and balance were analyzed in the anterior-posterior (AP) and medial-lateral (ML) axes during ambulation. T-tests for each measure comparing the difference-of-differences to a zero change at baseline returned statistically significant reductions in both AP (p < 0.0001; 95% CI: 1.368- 2.976) and ML (p = 0.0002; 95% CI: 1.472- 4.173) imbalances using specifically directed yoked prisms to correct the visual midline deviation. These findings demonstrate that yoked prisms have the potential to provide a cost-effective means to restore the visual midline thereby improving balance, reduce RoF and subsequent injury.
NASA Astrophysics Data System (ADS)
Maravelis, A. G.; Pantopoulos, G.; Tserolas, P.; Zelilidis, A.
2015-06-01
Architecture of the well-exposed ancient forearc basin successions of northeast Aegean Sea, Greece, provides useful insights into the interplay between arc magmatism, accretionary prism exhumation, and sedimentary deposition in forearc basins. The upper Eocene-lower Oligocene basin fill of the southern Thrace forearc basin reflects the active influence of the uplifted accretionary prism. Deep-marine sediments predominate the basin fill that eventually shoals upwards into shallow-marine sediments. This trend is related to tectonically driven uplift and compression. Field, stratigraphic, sedimentological, petrographic, geochemical, and provenance data on the lower Oligocene shallow-marine deposits revealed the accretionary prism (i.e. Pindic Cordillera or Biga Peninsula) as the major contributor of sediments into the forearc region. Field investigations in these shallow-marine deposits revealed the occurrence of conglomerates with: (1) mafic and ultramafic igneous rock clasts, (2) low-grade metamorphic rock fragments, and (3) sedimentary rocks. The absence of felsic volcanic fragments rules out influence of a felsic source rock. Geochemical analysis indicates that the studied rocks were accumulated in an active tectonic setting with a sediment source of mainly mafic composition, and palaeodispersal analysis revealed a NE-NNE palaeocurrent trend, towards the Rhodopian magmatic arc. Thus, these combined provenance results make the accretionary prism the most suitable candidate for the detritus forming these shallow-marine deposits.
Development and application of GIS-based PRISM integration through a plugin approach
NASA Astrophysics Data System (ADS)
Lee, Woo-Seop; Chun, Jong Ahn; Kang, Kwangmin
2014-05-01
A PRISM (Parameter-elevation Regressions on Independent Slopes Model) QGIS-plugin was developed on Quantum GIS platform in this study. This Quantum GIS plugin system provides user-friendly graphic user interfaces (GUIs) so that users can obtain gridded meteorological data of high resolutions (1 km × 1 km). Also, this software is designed to run on a personal computer so that it does not require an internet access or a sophisticated computer system. This module is a user-friendly system that a user can generate PRISM data with ease. The proposed PRISM QGIS-plugin is a hybrid statistical-geographic model system that uses coarse resolution datasets (APHRODITE datasets in this study) with digital elevation data to generate the fine-resolution gridded precipitation. To validate the performance of the software, Prek Thnot River Basin in Kandal, Cambodia is selected for application. Overall statistical analysis shows promising outputs generated by the proposed plugin. Error measures such as RMSE (Root Mean Square Error) and MAPE (Mean Absolute Percentage Error) were used to evaluate the performance of the developed PRISM QGIS-plugin. Evaluation results using RMSE and MAPE were 2.76 mm and 4.2%, respectively. This study suggested that the plugin can be used to generate high resolution precipitation datasets for hydrological and climatological studies at a watershed where observed weather datasets are limited.
Systematic comparisons between PRISM version 1.0.0, BAP, and CSMIP ground-motion processing
Kalkan, Erol; Stephens, Christopher
2017-02-23
A series of benchmark tests was run by comparing results of the Processing and Review Interface for Strong Motion data (PRISM) software version 1.0.0 to Basic Strong-Motion Accelerogram Processing Software (BAP; Converse and Brady, 1992), and to California Strong Motion Instrumentation Program (CSMIP) processing (Shakal and others, 2003, 2004). These tests were performed by using the MatLAB implementation of PRISM, which is equivalent to its public release version in Java language. Systematic comparisons were made in time and frequency domains of records processed in PRISM and BAP, and in CSMIP, by using a set of representative input motions with varying resolutions, frequency content, and amplitudes. Although the details of strong-motion records vary among the processing procedures, there are only minor differences among the waveforms for each component and within the frequency passband common to these procedures. A comprehensive statistical evaluation considering more than 1,800 ground-motion components demonstrates that differences in peak amplitudes of acceleration, velocity, and displacement time series obtained from PRISM and CSMIP processing are equal to or less than 4 percent for 99 percent of the data, and equal to or less than 2 percent for 96 percent of the data. Other statistical measures, including the Euclidian distance (L2 norm) and the windowed root mean square level of processed time series, also indicate that both processing schemes produce statistically similar products.
NASA Astrophysics Data System (ADS)
Bostick, Randall L.; Perram, Glen P.; Tuttle, Ronald
2009-05-01
The Air Force Institute of Technology (AFIT) has built a rotating prism chromotomographic hyperspectral imager (CTI) with the goal of extending the technology to exploit spatially extended sources with quickly varying (> 10 Hz) phenomenology, such as bomb detonations and muzzle flashes. This technology collects successive frames of 2-D data dispersed at different angles multiplexing spatial and spectral information which can then be used to reconstruct any arbitrary spectral plane(s). In this paper, the design of the AFIT instrument is described and then tested against a spectral target with near point source spatial characteristics to measure spectral and spatial resolution. It will be shown that, in theory, the spectral and spatial resolution in the 3-D spectral image cube is the nearly the same as a simple prism spectrograph with the same design. However, error in the knowledge of the prism linear dispersion at the detector array as a function of wavelength and projection angle will degrade resolution without further corrections. With minimal correction for error and use of a simple shift-and-add reconstruction algorithm, the CTI is able to produce a spatial resolution of about 2 mm in the object plane (234 μrad IFOV) and is limited by chromatic aberration. A spectral resolution of less than 1nm at shorter wavelengths is shown, limited primarily by prism dispersion.
Adaptation to Laterally Displacing Prisms in Anisometropic Amblyopia.
Sklar, Jaime C; Goltz, Herbert C; Gane, Luke; Wong, Agnes M F
2015-06-01
Using visual feedback to modify sensorimotor output in response to changes in the external environment is essential for daily function. Prism adaptation is a well-established experimental paradigm to quantify sensorimotor adaptation; that is, how the sensorimotor system adapts to an optically-altered visuospatial environment. Amblyopia is a neurodevelopmental disorder characterized by spatiotemporal deficits in vision that impacts manual and oculomotor function. This study explored the effects of anisometropic amblyopia on prism adaptation. Eight participants with anisometropic amblyopia and 11 visually-normal adults, all right-handed, were tested. Participants pointed to visual targets and were presented with feedback of hand position near the terminus of limb movement in three blocks: baseline, adaptation, and deadaptation. Adaptation was induced by viewing with binocular 11.4° (20 prism diopter [PD]) left-shifting prisms. All tasks were performed during binocular viewing. Participants with anisometropic amblyopia required significantly more trials (i.e., increased time constant) to adapt to prismatic optical displacement than visually-normal controls. During the rapid error correction phase of adaptation, people with anisometropic amblyopia also exhibited greater variance in motor output than visually-normal controls. Amblyopia impacts on the ability to adapt the sensorimotor system to an optically-displaced visual environment. The increased time constant and greater variance in motor output during the rapid error correction phase of adaptation may indicate deficits in processing of visual information as a result of degraded spatiotemporal vision in amblyopia.
DOT National Transportation Integrated Search
1979-01-01
The original rock prism specimens were prepared and the early length change data were taken as part of a Federal Highway Administration project on the behavior of carbonate aggregates in concrete. It had been shown that the length changes of the aggr...
Energy Relations in Russia: Administration, Politics and Security
ERIC Educational Resources Information Center
Makarychev, Andrey
2005-01-01
This chapter analyses energy relations through a prism of three interlinked concepts: administration, politics and security. This triad describes the basic approaches to questions about technical, politicised and securitised energy. These three concepts are logically linked to one another and represent an elementary matrix; a prism through which…
Preparation of regional shorebird monitoring plans
Jonathan Bart; Ann Manning; Susan Thomas; Catherine Wightman
2005-01-01
Shorebird monitoring programs in Canada and the United States are being developed under the auspices of PRISM, the Program for Regional and International Shorebird Monitoring. PRISM provides a single blueprint for implementing the monitoring proposals in the shorebird conservation plans prepared recently in Canada and the United States. It includes four segments:...
Family Perspectives: Using a Cultural Prism to Understand Families from Asian Cultural Backgrounds
ERIC Educational Resources Information Center
Lee, Suk-Hyang; Turnbull, Ann P.; Zan, Fei
2009-01-01
Educators can better serve students who come from diverse cultural backgrounds by understanding the differing cultural values of these students and their families. This article explores different cultural perspectives using a cultural prism approach, focused most specifically on the Korean and Chinese cultures. (Contains 2 tables.)
Uncovering the Stories about Social Class
ERIC Educational Resources Information Center
Harper, Vernon B., Jr.
2006-01-01
Social class remains one of the chief prisms through which reality is interpreted. It is vital for a student to understand how this prism influences their internal representations of themselves and others. In this activity, social class is viewed as a social construction of perceived financial and/or economic status developed through societal…
Portable Remote Imaging Spectrometer (PRISM): Laboratory and Field Calibration
NASA Technical Reports Server (NTRS)
Mouroulis, Pantazis; Van Gorp, Byron; Green, Robert O.; Eastwood, Michael; Boardman, Joseph; Richardson, Brandon S.; Rodriguez, Jose I.; Urquiza, Eugenio; Franklin, Brian D.; Gao, Bo-Cai
2012-01-01
We report the characteristics of the Portable Remote Imaging Spectrometer, an airborne sensor specifically designed for the challenges of coastal ocean research. PRISM has high signal to noise ratio and uniformity, as well as low polarization sensitivity. Acquisition of high quality data has been demonstrated with the first engineering flight.
The Pacific Oaks College's Prism Principles Professional Development Approach
ERIC Educational Resources Information Center
Beyer, Kalani
2012-01-01
In a struggling atmosphere for education, one college is optimistic about the future by offering school districts its PRISM Principles professional development as a means to ensure that "no child is left behind." Pacific Oaks College & Children's School is known for its premiere programs in early childhood education, human…
Two-pass-internal second-harmonic generation using a prism coupler.
NASA Technical Reports Server (NTRS)
Gonzalez, D. G.; Nieh, S. T. K.; Steier, W. H.
1973-01-01
A dispersive quartz prism is used to couple the total second harmonic generated in both directions by an internal cavity frequency doubler. The study shows that the dispersion of air and mirror reflection phase shifts can be compensated for by a slight nonphase match condition in the doubler.
Students' Reasoning about Invariance of Volume as a Quantity
ERIC Educational Resources Information Center
Kara, Melike
2013-01-01
The aims of this study were to investigate how upper-elementary-grade students compare the volume of rectangular prisms of equal volume (specifically, students' noticing and reasoning for invariance of volume and coordination of the three linear dimensions of rectangular prisms) and how students' levels of sophistication in volume measurement…
Comparing the Volumes of Rectangular Prisms
ERIC Educational Resources Information Center
Assuah, Charles K.; Wiest, Lynda R.
2010-01-01
Can middle-grades students determine which of two rectangular prisms has a larger volume? Can they do so without using a formula? Geometry, and particularly the concept of volume, is important in many subjects, such as physics and chemistry. Students greatly enhance their mathematics knowledge when they make generalizations and construct arguments…
Comparing Volumes of Prisms and Pyramids
ERIC Educational Resources Information Center
Vinogradova, Natalya
2012-01-01
Students' experience in using formulas for volumes is often limited to substituting numbers into given formulas. An activity presented in this article may help students make connections between the formulas for volumes of prisms and volumes of pyramids. In addition, some interesting facts from number theory arise, demonstrating strong connections…
NASA Astrophysics Data System (ADS)
Greenslade, Thomas B.
2010-04-01
Students all know that reflection from a plane mirror produces an image that is reversed right to left and so cannot be read by anyone but Leonardo da Vinci, who kept his notes in mirror writing. A useful counter-example is the Porro prism, which produces an image that is not reversed.
A tidal prism model was developed to calculate temporal changes in the spatially averaged concentration of three state variables: phytoplankton, dissolved inorganic nitrogen, and detritus. Our main objective was to develop a model to help us understand the causes of phytoplankton...
G.W. Ritchey's Optical Work for the Army during WWI.
NASA Astrophysics Data System (ADS)
Abrahams, Peter
2015-01-01
During the first World War, the Mount Wilson optical shop was remodeled into a production facility, making lenses and prisms for military optics. G.W. Ritchey, H.S. Kinney, and J.S. Dalton managed the project, joined by Ritchey's son Willis and a large team of workers. Tens of thousands of lenses and prisms were produced, notably the exacting roof prisms needed for altimeters.This sizeable project is documented in correspondence and a 'Report on Technical Details of Optical Work', authored by G.W. Ritchey and reproduced in typewriter carbon copy with tipped-in photographs. The retrofitting of the MWO optical shop, and the complicated production methods, are detailed in the report.
1-D ELECTRO-OPTIC BEAM STEERING DEVICE
Wang, Wei-Chih; Tsui, Chi Leung
2011-01-01
In this paper, we present the design and fabrication of a 1D beam steering device based on planar electro-optic thermal-plastic prisms and a collimator lens array. With the elimination of moving parts, the proposed device is able to overcome the mechanical limitations of present scanning devices, such as fatigue and low operating frequency, while maintaining a small system footprint (~0.5mm×0.5mm). From experimental data, our prototype device is able to achieve a maximum deflection angle of 5.6° for a single stage prism design and 29.2° for a cascaded three prisms stage design. The lens array shows a 4µm collimated beam diameter. PMID:22199458
Design of a multi-channel free space optical interconnection component
NASA Astrophysics Data System (ADS)
Jia, Da-Gong; Zhang, Pei-Song; Jing, Wen-Cai; Tan, Jun; Zhang, Hong-Xia; Zhang, Yi-Mo
2008-11-01
A multi-channel free space optical interconnection component, fiber optic rotary joint, was designed using a Dove prism. When the Dove prism is rotated an angle of α around the longitudinal axis, the image rotates an angle of 2 α. The optical interconnection component consists of the signal transmission system, Dove prim and driving mechanism. The planetary gears are used to achieve the speed ratio of 2:1 between the total optical interconnection component and the Dove prism. The C-lenses are employed to couple different optical signals in the signal transmission system. The coupling loss between the receiving fiber of stationary part and the transmitting fiber of rotary part is measured.
He, Zhiqiao; Wang, Danfen; Tang, Juntao; Song, Shuang; Chen, Jianmeng; Tao, Xinyong
2017-03-01
A quasi-hexagonal prism-shaped carbon nitride (H-C 3 N 4 ) was synthesized from urea-derived C 3 N 4 (U-C 3 N 4 ) using an alkaline hydrothermal process. U-C 3 N 4 decomposition followed by hydrogen bond rearrangement of hydrolyzed products leads to the formation of a quasi-hexagonal prism-shaped structure. The H-C 3 N 4 catalysts displayed superior activity in the photoreduction of CO 2 with H 2 O compared to U-C 3 N 4 . The enhanced photocatalytic activities can be attributed to the promotion of incompletely coordinated nitrogen atom formation in the C 3 N 4 molecules. Graphical abstract ᅟ.
1993-03-24
Lens BPG1 Lasr -Brewster Telescope "N 8 1 a I ISF DgD-*- Analyzer Prism Grating -0 V I LED.u Collimation Fine-Adjust K-*R- Risley Prisms-- ,,.,.BPG (64...x 32) 50:50 BS,_____ Mnput 3 Inp V4 Output I ,_"U 7!’:I Image PB NS 6" Risley Prisms V44 Inpu O P •/4Objective Lens ge Slngtge Electrical S-SEED...the laser pen. The fine angular (0 to 15 arc-minutes) alignment of the beam in both directions can be done optically with Risley steering wedgcs
Watching Nanoscale Self-Assembly Kinetics of Gold Prisms in Liquids
NASA Astrophysics Data System (ADS)
Kim, Juyeong; Ou, Zihao; Jones, Matthew R.; Chen, Qian
We use liquid-phase transmission electron microscopy to watch self-assembly of gold triangular prisms into polymer-like structures. The in situ dynamics monitoring enabled by liquid-phase transmission electron microscopy, single nanoparticle tracking, and the marked conceptual similarity between molecular reactions and nanoparticle self-assembly combined elucidate the following mechanistic understanding: a step-growth polymerization based assembly statistics, kinetic pathways sampling particle curvature dependent energy minima and their interconversions, and directed assembly into polymorphs (linear or cyclic chains) through in situ modulation of the prism bonding geometry. Our study bridges the constituent kinetics on the molecular and nanoparticle length scales, which enriches the design rules in directed self-assembly of anisotropic nanoparticles.
NASA Astrophysics Data System (ADS)
Lyashko, A. D.
2017-11-01
A new analytical presentation of the solution for steady-state oscillations of orthotopic rectangular prism is found. The corresponding infinite system of linear algebraic equations has been deduced by the superposition method. A countable set of precise eigenfrequencies and elementary eigenforms is found. The identities are found which make it possible to improve the convergence of all the infinite series in the solution of the problem. All the infinite series in presentation of solution are analytically summed up. Numerical calculations of stresses in the rectangular orthotropic prism with a uniform along the border and harmonic in time load on two opposite faces have been performed.
Mathematical Explorations: Maximizing Volume with Solids and Nets
ERIC Educational Resources Information Center
Miles, Victoria L.
2014-01-01
One of the most common household polyhedra is a cereal box. For over 100 years, American companies like Kellogg's™ have packaged cereal in containers shaped like rectangular prisms. Why is a rectangular prism the most commonly used solid for holding cereal? Would another design work equally or more efficient? This article describes an…
Understanding University Reform in Japan through the Prism of the Social Sciences
ERIC Educational Resources Information Center
Goodman, Roger
2008-01-01
This article looks at current university reforms in Japan through two slightly different social science prisms: how social science methodologies and theories can help us understand those reforms better and how social science teaching in universities will be affected by the current reform processes. (Contains 3 tables and 7 notes.)
ERIC Educational Resources Information Center
Ribeiro, Jair Lúcio Prados
2018-01-01
We only became aware of the existence of bed prism spectacles when a student brought them to the classroom and asked us about how they work. The device proved to be a fertile source of curiosity among the students, and, to be properly understood, it required us to develop a comparison between reflection in a typical mirror and total internal…
Preserving with Prisms: Producing Nets
ERIC Educational Resources Information Center
Prummer, Kathy E.; Amador, Julie M.; Wallin, Abraham J.
2016-01-01
Two mathematics teachers in a small rural school decided to create a task that would engage seventh graders. The goal of the real-world activity was to help students develop geometric and spatial reasoning and to support their understanding of volume of rectangular prisms. The impetus for the task came from the teachers' desire to engage students…
An assessment of the Crossed Porro Prism Resonator
NASA Astrophysics Data System (ADS)
See, B. A.; Fueloep, K.; Seymour, R.
1980-08-01
Lasers with crossed porro prism resonators for military laser rangefinder and designator applications are studied. Properties of these devices are reviewed and advantages over normal mirror resonators are examined. The theory of operating is treated and the mechanical stability and other features of the laser are examined and compared to standard mirror resonators.
Direct AFM observation of an opening event of a DNA cuboid constructed via a prism structure.
Endo, Masayuki; Hidaka, Kumi; Sugiyama, Hiroshi
2011-04-07
A cuboid structure was constructed using a DNA origami design based on a square prism structure. The structure was characterized by atomic force microscopy (AFM) and dynamic light scattering. The real-time opening event of the cuboid was directly observed by high-speed AFM.
This dataset represents climate observations within individual, local NHDPlusV2 catchments and upstream, contributing watersheds. Attributes of the landscape layer were calculated for every local NHDPlusV2 catchment and accumulated to provide watershed-level metrics. (See Supplementary Info for Glossary of Terms) PRISM is a set of monthly, yearly, and single-event gridded data products of mean temperature and precipitation, max/min temperatures, and dewpoints, primarily for the United States. In-situ point measurements are ingested into the PRISM (Parameter elevation Regression on Independent Slopes Model) statistical mapping system. The PRISM products use a weighted regression scheme to account for complex climate regimes associated with orography, rain shadows, temperature inversions, slope aspect, coastal proximity, and other factors. (see Data Sources for links to NHDPlusV2 data and USGS Data) These data are summarized by local catchment and by watershed to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).
This dataset represents climate observations within individual, local NHDPlusV2 catchments and upstream, contributing watersheds. Attributes of the landscape layer were calculated for every local NHDPlusV2 catchment and accumulated to provide watershed-level metrics. (See Supplementary Info for Glossary of Terms) PRISM is a set of monthly, yearly, and single-event gridded data products of mean temperature and precipitation, max/min temperatures, and dewpoints, primarily for the United States. In-situ point measurements are ingested into the PRISM (Parameter elevation Regression on Independent Slopes Model) statistical mapping system. The PRISM products use a weighted regression scheme to account for complex climate regimes associated with orography, rain shadows, temperature inversions, slope aspect, coastal proximity, and other factors. (see Data Sources for links to NHDPlusV2 data and USGS Data) These data are summarized by local catchment and by watershed to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).
NASA Astrophysics Data System (ADS)
Korhonen, Hannu; Syväluoto, Aki; Leskinen, Jari T. T.; Lappalainen, Reijo
2018-01-01
Nowadays, an environmental protection is needed for a number of optical applications in conditions quickly impairing the clarity of optical surfaces. Abrasion resistant optical coatings applied onto plastics are usually based on alumina or polysiloxane technology. In many applications transparent glasses and ceramics need a combination of abrasive and chemically resistant shielding or other protective solutions like coatings. In this study, we intended to test our hypothesis that clear and pore free alumina coating can be uniformly distributed on glass prisms by ultra short pulsed laser deposition (USPLD) technique to protect the sensitive surfaces against abrasives. Abrasive wear tests were carried out by the use of SiC emery paper using specified standard procedures. After the wear tests the measured transparencies of coated prisms turned out to be close those of the prisms before coating. The coating on sensitive surfaces consistently displayed enhanced wear resistance exhibiting still high quality, even after severe wear testing. Furthermore, the coating modified the surface properties towards hydrophobic nature in contrast to untreated prisms, which became very hydrophilic especially due to wear.
Crystal structure and magnetic properties of Sr 4Mn 2NiO 9
NASA Astrophysics Data System (ADS)
El Abed, Ahmed; Gaudin, Etienne; Lemaux, Sylvain; Darriet, Jacques
2001-12-01
The crystal structure of Sr 4Mn 2NiO 9 has been refined on single crystal. This phase belongs to the series A 1+ x(A 'xB 1- x)O 3 ( x=1/3) related to the 2H-hexagonal perovskite. The structure contains transition metals in chains of oxide polyhedra (trigonal prisms and octahedra); neighboring chains are separated from each other by the Sr atoms. The sequence of the face sharing polyhedra along the chains is two octahedra + one trigonal prism. Mn occupies the octahedra and Ni is disordered in the trigonal prism with ≈80% in the pseudo square faces of the prism and ≈20% at the centre. This result has been confirmed by XANES experiments at Mn K and Ni K edges, respectively. Sr 4Mn 2NiO 9 is antiferromagnetic with a Néel temperature at T=3 K. The Curie constant measured at high temperature is in good agreement with ≈80% of the Ni 2+ ions in the spin state configuration S=0.
PRISM3/GISS Topographic Reconstruction
Sohl, Linda E.; Chandler, Mark A.; Schmunk, Robert B.; Mankoff, Ken; Jonas, Jeffrey A.; Foley, Kevin M.; Dowsett, Harry J.
2009-01-01
The PRISM3/GISS topographic reconstruction is one of the global data sets incorporated into a new reconstruction for the mid-Piacenzian warm interval of the Pliocene, at about 3.3 to 3.0 Ma. The PRISM3/GISS topography-gridded data set is a digitization of a graphical reconstruction, provided at 2 deg x 2 deg resolution and based on updated paleoaltimetry data and a refined land/ocean mask. Mid-Piacenzian topography as shown in this data set is generally quite similar to modern topography, with three notable differences: (1) the coastline as shown is 25 meters higher than modern sea level, reflecting the hypothesized reduction in ice sheet volume; (2) Hudson Bay is filled in to low elevation, in the absence of evidence for submergence at that time; and (3) the West Antarctic ice sheet is absent, permitting open seaways to exist in Ellsworth and Marie Byrd Lands. Two alternate ice sheet configurations with corresponding vegetation schemes are available; one is a minor modification of the PRISM2 ice reconstruction, and one is derived from the British Antarctic Survey Ice Sheet Model (BAS ISM).
A novel and compact spectral imaging system based on two curved prisms
NASA Astrophysics Data System (ADS)
Nie, Yunfeng; Bin, Xiangli; Zhou, Jinsong; Li, Yang
2013-09-01
As a novel detection approach which simultaneously acquires two-dimensional visual picture and one-dimensional spectral information, spectral imaging offers promising applications on biomedical imaging, conservation and identification of artworks, surveillance of food safety, and so forth. A novel moderate-resolution spectral imaging system consisting of merely two optical elements is illustrated in this paper. It can realize the function of a relay imaging system as well as a 10nm spectral resolution spectroscopy. Compared to conventional prismatic imaging spectrometers, this design is compact and concise with only two special curved prisms by utilizing two reflective surfaces. In contrast to spectral imagers based on diffractive grating, the usage of compound-prism possesses characteristics of higher energy utilization and wider free spectral range. The seidel aberration theory and dispersive principle of this special prism are analyzed at first. According to the results, the optical system of this design is simulated, and the performance evaluation including spot diagram, MTF and distortion, is presented. In the end, considering the difficulty and particularity of manufacture and alignment, an available method for fabrication and measurement is proposed.
How to measure slab-off and reverse slab prism in spectacle lenses.
Christoff, Alexander; Guyton, David L
2007-08-01
It is well known that new spectacle lenses for the correction of anisometropia can induce diplopia with reading. The difference in the powers of the lenses induces a net prismatic effect that can cause double vision through off-center areas of the lenses. This is particularly bothersome when patients try to read, often noting vertical double vision in attempted downgaze, especially through multifocal add segments. This induced prismatic effect can be compensated at one level of downgaze by the use of slab-off or reverse slab prism. Typically the slab-off correction is ground into the stronger minus, or weaker plus lens. Reverse slab is ground into the weaker minus, or stronger plus, lens. Unfortunately, determining the amount of slab-off prism already incorporated into spectacle lenses is nonintuitive and inconvenient. This usually requires the use of a lens clock, which is not widely accessible to many ophthalmology practices. A simple technique, described in the past but poorly known, is illustrated here for quickly measuring slab-off and reverse slab prism prescription lenses in the clinic with a common manual lens meter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stein, Joshua; Burnham, Laurie; Lave, Matthew Samuel
A 9.6 kW test array of Prism bifacial modules and reference monofacial modules installed in February 2016 at the New Mexico Regional Test Center has produced one year of performance data. The data reveal that the Prism modules are out-performing the monofacial modules, with bifacial gains in energy over the twelve-month period ranging from 17% to 132%, depending on the orientation and ground albedo. These measured bifacial gains were found to be in good agreement with modeled bifacial gains using equations previously published by Prism Solar. The most dramatic increase in performance was seen among the vertically mounted, west-facing modules,more » where the bifacial modules produced more than double the energy of monofacial modules in the same orientation. Because peak energy generation (mid- morning and mid-afternoon) for these bifacial modules may best match load on the electric grid, the west-facing orientation may be more economically desirable than traditional south-facing module orientations (which peak at solar noon).« less
The Effect of Prism Orientation in the Indentation Testing of Human Molar Enamel
Braly, A.; Darnell, L.A.; Mann, A.B.; Teaford, M.F.; Weihs, T.P.
2007-01-01
Recent nanoindentation studies have demonstrated that the hardness and Young's modulus of human molar enamel decreases by more than 50% on moving from the occlusal surface to the dentin-enamel junction on cross-sectional samples. Possible sources of these variations are changes in local chemistry, microstructure, and prism orientation. This study investigates the latter source by performing nanoindentation tests at two different orientations relative to the hydroxyapatite prisms: parallel and perpendicular. A single sample volume was tested in order to maintain a constant chemistry and microstructure. The resulting data show very small differences between the two orientations for both hardness and Young's modulus. The 1.5 to 3.0% difference is significantly less than the standard deviations found within the data set. Thus, the variations in hardness and Young's modulus on cross-sectional samples of human molar are attributed to changes in local chemistry (varying levels of mineralization, organic matter, and water content) and changes in microstructure (varying volume fractions of inorganic crystals and organic matrix). The impact of prism orientation on mechanical properties measured by nanoindentation appears to be minimal. PMID:17449008
The Behaviour of Palm Oil Fibre Block Masonry Prism under Eccentric Compressive Loading
NASA Astrophysics Data System (ADS)
Mokhtar, Mardiha; Kolop, Roslan; Baizura Hamid, Nor; Kaamin, Masiri; Farhan Rosdi, Mohd; Ngadiman, Norhayati; Sahat, Suhaila
2017-08-01
Dry-stacked masonry offers great benefits in constructing masonry buildings. Several examples from previous research show that dry masonry is reasonable alternative to the traditional building system. By addition of fibre, the ductility and the propagation of cracking will be improved. This study investigates the dry stack oil palm fibre block prisms which were subjected to eccentricity compression loads. These concrete blocks were cast using a single mould with suitable fibre-cement composition namely 1:4 (cement: sand) and 0.40 water to the cement ratio based on cement weight. Prisms test using 400 (length) × 150 (width) × 510 (height) mm specimen was carried under eccentric load. There were forty eight (48) prisms built with different configurations based on their volume of fibre. In this study, one types of grout were used namely the fine grout of mix 1:3:2 (cement: sand: aggregate (5mm maximum). Based on the test performed, the failure mechanism and influencing parameters were discussed. From compressive strength test result, it shows that the strength of concrete block decreased with the increase of fibre used. Although the control sample has the higher strength compared to concrete with EFB, it can be seen from mode failure of masonry prism that fibre could extend the cracking time. These results show that the oil palm fibre blocks can improve the failure behaviour and suitable to be used as load bearing wall construction in Malaysia.
[Prism correction in heterophoria].
Kommerell, G; Kromeier, M
2002-01-01
Unlike heterotropia (= manifest strabismus), heterophoria (= latent strabismus) is not a primarily existing condition but is a reaction to an interruption of the sensory-motor feedback control system. The reaction consists of a deviation from the orthovergence position. Binocular vision causes a continuous calibration of the vergence position. This "orthophorisation" explains that in most persons, heterophoria differs only slightly from zero. Nevertheless, a small heterophoria is common (70-80% of the population). The need to compensate for heterophoria by sensory-motor fusion can cause asthenopic complaints, such as headaches with prolonged reading. Since a variety of other defects can lead to similar symptoms, a causal relationship with heterophoria can be assumed only after a thorough differential diagnosis. Prism spectacles or eye muscle surgery for heterophoria should be recommended only after prism trials in free space, which include yoked prisms as a placebo control. Heterophoria should be distinguished from "Winkelfehlsichtigkeit", which is a deviation from orthoposition that results from the "measuring and correcting methodology after H.-J. Haase" (MKH) and is based on the idea that fixation disparity, a minute deviation from orthovergence position, indicates an inability to overcome a larger "vergence angle at rest". Objective recordings have, however, revealed that the subjective tests with stereo cues applied in the MKH can mislead to the assumption of a fixation disparity although both eyes are aligned exactly to the fixation point. A trial conducted in the Netherlands concerning the therapy of asthenopic complaints showed no statistically significant advantage of prism spectacles determined with the MKH over conventional spectacles.
Barry, J C; Backes, A
1998-04-01
The alternating prism and cover test is the conventional test for the measurement of the angle of strabismus. The error induced by the prismatic effect of glasses is typically about 27-30%/10 D. Alternatively, the angle of strabismus can be measured with methods based on Purkinje reflex positions. This study examines the differences between three such options, taking into account the influence of glasses. The studied system comprised the eyes with or without glasses, a fixation object and a device for recording the eye position: in the case of the alternate prism and cover test, a prism bar was required; in the case of a Purkinje reflex based device, light sources for generation of reflexes and a camera for the documentation of the reflex positions were used. Measurements performed on model eyes and computer ray traces were used to analyze and compare the options. When a single corneal reflex is used, the misalignment of the corneal axis can be measured; the error in this measurement due to the prismatic effect of glasses was 7.6%/10 D, the smallest found in this study. The individual Hirschberg ratio can be determined by monocular measurements in three gaze directions. The angle of strabismus can be measured with Purkinje reflex based methods if the fundamental differences between these methods and the alternate prism and cover test, and if the influence of glasses and other sources of error are accounted for.
[A new method to test vertical ocular deviations using perilimbal light reflexes].
Breyer, Armin; Rütsche, Adrian; Gampe, Elisabeth; Mojon, Daniel S
2003-03-01
To develop a new diagnostic technique to determine vertical ocular deviations when the center of the pupil is covered by swollen eyelids in up- and downgaze. In upgaze (downgaze) the reflex of a diagnostic lamp held at about 50 cm distance from the patient is observed on the lower (upper) limbus. In the case of an asymmetric reflex, prisms are used to obtain symmetrical reflexes. The amount of prisms indicates the size of the vertical misalignment. In five healthy volunteers, the angles of vertical changes of gaze position were plotted against the prism size needed to recenter the perilimbal reflex. There was a linear correlation between the amount of upgaze changes in degrees and the strength of prisms used for compensation in degrees. This linear correlation was also found in downgaze. For both the correlation coefficient was r = 0.98 +/- 0.01. In upgaze the slope of the average regression line was 0.55 +/- 2.3 degrees, in downgaze - 4.1 +/- 0.8 degrees. A prism of 1 degrees corresponds in upgaze to a vertical deviation of about 1.3 +/- 0.14 degrees, in downgaze to a deviation of about 1.1 +/- 0.07 degrees. These results demonstrate that the perilimbal light reflex test is suitable for measuring simulated vertical ocular deviations. Therefore, the test may also be used in patients with vertical deviations who cannot be measured with classical methods. The method is more exact for measurements in upgaze.
NASA Astrophysics Data System (ADS)
Flemings, Peter B.; Saffer, Demian M.
2018-02-01
We predict pressure and stress from porosity in the Nankai accretionary prism with a critical state soil model that describes porosity as a function of mean stress and maximum shear stress, and assumes Coulomb failure within the wedge and uniaxial burial beneath it. At Ocean Drilling Program Sites 1174 and 808, we find that pore pressure in the prism supports 70% to 90% of the overburden (λu = 0.7 to 0.9), for a range of assumed friction angles (5-30°). The prism pore pressure is equal to or greater than that in the underthrust sediments even though the porosity is lower within the prism. The high pore pressures lead to a mechanically weak wedge that supports low maximum shear stress, and this in turn requires very low basal traction to remain consistent with the observed narrowly tapered wedge geometry. We estimate the décollement friction coefficient (μb) to be 0.08-0.38 (ϕb' = 4.6°-21°). Our approach defines a pathway to predict pressure in a wide range of environments from readily observed quantities (e.g., porosity and seismic velocity). Pressure and stress control the form of the Earth's collisional continental margins and play a key role in its greatest earthquakes. However, heretofore, there has been no systematic approach to relate material state (e.g., porosity), pore pressure, and stress in these systems.
Prism adaptation and generalization during visually guided locomotor tasks.
Alexander, M Scott; Flodin, Brent W G; Marigold, Daniel S
2011-08-01
The ability of individuals to adapt locomotion to constraints associated with the complex environments normally encountered in everyday life is paramount for survival. Here, we tested the ability of 24 healthy young adults to adapt to a rightward prism shift (∼11.3°) while either walking and stepping to targets (i.e., precision stepping task) or stepping over an obstacle (i.e., obstacle avoidance task). We subsequently tested for generalization to the other locomotor task. In the precision stepping task, we determined the lateral end-point error of foot placement from the targets. In the obstacle avoidance task, we determined toe clearance and lateral foot placement distance from the obstacle before and after stepping over the obstacle. We found large, rightward deviations in foot placement on initial exposure to prisms in both tasks. The majority of measures demonstrated adaptation over repeated trials, and adaptation rates were dependent mainly on the task. On removal of the prisms, we observed negative aftereffects for measures of both tasks. Additionally, we found a unilateral symmetric generalization pattern in that the left, but not the right, lower limb indicated generalization across the 2 locomotor tasks. These results indicate that the nervous system is capable of rapidly adapting to a visuomotor mismatch during visually demanding locomotor tasks and that the prism-induced adaptation can, at least partially, generalize across these tasks. The results also support the notion that the nervous system utilizes an internal model for the control of visually guided locomotion.
Superconducting magnetic Wollaston prism for neutron spin encoding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, F., E-mail: fankli@indiana.edu; Parnell, S. R.; Wang, T.
2014-05-15
A magnetic Wollaston prism can spatially split a polarized neutron beam into two beams with different neutron spin states, in a manner analogous to an optical Wollaston prism. Such a Wollaston prism can be used to encode the trajectory of neutrons into the Larmor phase associated with their spin degree of freedom. This encoding can be used for neutron phase-contrast radiography and in spin echo scattering angle measurement (SESAME). In this paper, we show that magnetic Wollaston prisms with highly uniform magnetic fields and low Larmor phase aberration can be constructed to preserve neutron polarization using high temperature superconducting (HTS)more » materials. The Meissner effect of HTS films is used to confine magnetic fields produced electromagnetically by current-carrying HTS tape wound on suitably shaped soft iron pole pieces. The device is cooled to ∼30 K by a closed cycle refrigerator, eliminating the need to replenish liquid cryogens and greatly simplifying operation and maintenance. A HTS film ensures that the magnetic field transition within the prism is sharp, well-defined, and planar due to the Meissner effect. The spin transport efficiency across the device was measured to be ∼98.5% independent of neutron wavelength and energizing current. The position-dependent Larmor phase of neutron spins was measured at the NIST Center for Neutron Research facility and found to agree well with detailed simulations. The phase varies linearly with horizontal position, as required, and the neutron beam shows little depolarization. Consequently, the device has advantages over existing devices with similar functionality and provides the capability for a large neutron beam (20 mm × 30 mm) and an increase in length scales accessible to SESAME to beyond 10 μm. With further improvements of the external coupling guide field in the prototype device, a larger neutron beam could be employed.« less
Performance of PRISM III and PELOD-2 scores in a pediatric intensive care unit.
Gonçalves, Jean-Pierre; Severo, Milton; Rocha, Carla; Jardim, Joana; Mota, Teresa; Ribeiro, Augusto
2015-10-01
The study aims were to compare two models (The Pediatric Risk of Mortality III (PRISM III) and Pediatric Logistic Organ Dysfunction (PELOD-2)) for prediction of mortality in a pediatric intensive care unit (PICU) and recalibrate PELOD-2 in a Portuguese population. To achieve the previous goal, a prospective cohort study to evaluate score performance (standardized mortality ratio, discrimination, and calibration) for both models was performed. A total of 556 patients consecutively admitted to our PICU between January 2011 and December 2012 were included in the analysis. The median age was 65 months, with an interquartile range of 1 month to 17 years. The male-to-female ratio was 1.5. The median length of PICU stay was 3 days. The overall predicted number of deaths using PRISM III score was 30.8 patients whereas that by PELOD-2 was 22.1 patients. The observed mortality was 29 patients. The area under the receiver operating characteristics curve for the two models was 0.92 and 0.94, respectively. The Hosmer and Lemeshow goodness-of-fit test showed a good calibration only for PRISM III (PRISM III: χ (2) = 3.820, p = 0.282; PELOD-2: χ (2) = 9.576, p = 0.022). Both scores had good discrimination. PELOD-2 needs recalibration to be a better reliable prediction tool. • PRISM III (Pediatric Risk of Mortality III) and PELOD (Pediatric Logistic Organ Dysfunction) scores are frequently used to assess the performance of intensive care units and also for mortality prediction in the pediatric population. • Pediatric Logistic Organ Dysfunction 2 is the newer version of PELOD and has recently been validated with good discrimination and calibration. What is New: • In our population, both scores had good discrimination. • PELOD-2 needs recalibration to be a better reliable prediction tool.
NASA Astrophysics Data System (ADS)
Bertin, Xavier; Chaumillon, Eric; Sottolichio, Aldo; Pedreros, Rodrigo
2005-06-01
Tidal inlet characteristics are controlled by wave energy, tidal range, tidal prism, sediment supply and direction and rates of sand delivered to the inlet. This paper deals with the relations between inlet and lagoon evolutions, linked by the tidal prism. Our study is focused on the Maumusson Inlet and the Marennes-Oléron Bay (first oyster farming area in Europe), located on the western coast of France. The tidal range (2-6 m) and wave climate (mean height: 1.5 m) place this tidal inlet system in the mixed energy (tide, waves), tide-dominated category. The availability of high-resolution bathymetric data since 1824 permits to characterise and quantify accurately morphological changes of both the inlet and the tidal bay. Since 1824, sediment filling of the tidal bay has led to a 20% decrease in its water volume, and a 35% reduction of the inlet throat section. Furthermore, the bay is subjected to a very high anthropic pressure, mainly related to oyster farming. Thus, both natural and human-related processes seem relevant to explain high sedimentation rates. Current measurements, hydrodynamic modelling and cross-sectional area of the inlet throat are used in order to quantify tidal prism changes since 1824. Both flood and ebb tidal prism decreased by 35%. Decrease in the Marennes-Oléron Bay water volume is inferred to be responsible for a part of tidal prism decrease at the inlet. Tidal prisms decrease may also be explained by an increase in frictional resistance to tidal wave propagation, due to a general shoaling and oyster farms in the bay. A conceptual model is proposed, taking into account natural and human-related sedimentation processes, and explaining tidal inlet response to tidal bay evolutions.
NASA Astrophysics Data System (ADS)
de Moor, A.; Trehu, A. M.; Tryon, M. D.
2015-12-01
To investigate the dynamic response of the outer accretionary wedge updip from the patch of greatest slip during the Mw8.8 2010 Maule earthquake, 10 Ocean Bottom Seismometers (OBS) were deployed from May 2012 to March 2013 in a small array with an inter-instrument spacing of ~12 km . Nine instruments were recovered, with 4 recording data on 3 intermediate-band 3-component seismometers and a differential pressure gauge and 5 recording data from absolute pressure gauges. [note: All instruments were also equipped with a fluid flow meter sensitive to flow rates as low as 0.0001 cm/yr in or out of the sediments. However, no flow signal was detected.] Here we present hypocenters for 569 local events that have S-P times less than 17 seconds (i.e. within ~125 km of the array) using hand-picked arrival times and a 1D velocity model derived from a 2D seismic refraction profile through the region (Moscoso et al 2011, EPSL). We analyze the distribution of seismicity in the context of published slip models, ChilePEPPER high-resolution seismic reflection data, critical taper analysis done by Cubas et al 2013 (EPSL), and offshore gravity data. The data show distinct segmentation within the outer prism. The northern section of the study area is characterized by a lack of seismicity, accretion of nearly all incoming sediment and a prism at critical taper. In contrast, abundant seismicity, significant sediment underthrusting at the deformation front and a prism below critical taper angle characterize the southern part of the study area. Both coseismic slip and post-rupture local seismicity can be related to density anomalies within the upper plate as revealed by free air gravity data corrected for the effects of bathymetry and the subducting plate. [ChilePEPPER - Project Evaluating Prism Post-Earthquake Response
Standardization of Questions in Rare Disease Registries: The PRISM Library Project.
Richesson, Rachel Lynn; Shereff, Denise; Andrews, James Everett
2012-10-10
Patient registries are often a helpful first step in estimating the impact and understanding the etiology of rare diseases - both requisites for the development of new diagnostics and therapeutics. The value and utility of patient registries rely on the use of both well-constructed structured research questions and relevant answer sets accompanying them. There are currently no clear standards or specifications for developing registry questions, and there are no banks of existing questions to support registry developers. This paper introduces the [Rare Disease] PRISM (Patient Registry Item Specifications and Metadata for Rare Disease) project, a library of standardized questions covering a broad spectrum of rare diseases that can be used to support the development of new registries, including Internet-based registries. A convenience sample of questions was identified from well-established (>5 years) natural history studies in various diseases and from several existing registries. Face validity of the questions was determined by review by many experts (both terminology experts at the College of American Pathologists (CAP) and research and informatics experts at the University of South Florida (USF)) for commonality, clarity, and organization. Questions were re-worded slightly, as needed, to make the full semantics of the question clear and to make the questions generalizable to multiple diseases where possible. Questions were indexed with metadata (structured and descriptive information) using a standard metadata framework to record such information as context, format, question asker and responder, and data standards information. At present, PRISM contains over 2,200 questions, with content of PRISM relevant to virtually all rare diseases. While the inclusion of disease-specific questions for thousands of rare disease organizations seeking to develop registries would present a challenge for traditional standards development organizations, the PRISM library could serve as a platform to liaison between rare disease communities and existing standardized controlled terminologies, item banks, and coding systems. If widely used, PRISM will enable the re-use of questions across registries, reduce variation in registry data collection, and facilitate a bottom-up standardization of patient registries. Although it was initially developed to fulfill an urgent need in the rare disease community for shared resources, the PRISM library of patient-directed registry questions can be a valuable resource for registries in any disease - whether common or rare. N/A.
Standardization of Questions in Rare Disease Registries: The PRISM Library Project
Shereff, Denise; Andrews, James Everett
2012-01-01
Background Patient registries are often a helpful first step in estimating the impact and understanding the etiology of rare diseases - both requisites for the development of new diagnostics and therapeutics. The value and utility of patient registries rely on the use of both well-constructed structured research questions and relevant answer sets accompanying them. There are currently no clear standards or specifications for developing registry questions, and there are no banks of existing questions to support registry developers. Objective This paper introduces the [Rare Disease] PRISM (Patient Registry Item Specifications and Metadata for Rare Disease) project, a library of standardized questions covering a broad spectrum of rare diseases that can be used to support the development of new registries, including Internet-based registries. Methods A convenience sample of questions was identified from well-established (>5 years) natural history studies in various diseases and from several existing registries. Face validity of the questions was determined by review by many experts (both terminology experts at the College of American Pathologists (CAP) and research and informatics experts at the University of South Florida (USF)) for commonality, clarity, and organization. Questions were re-worded slightly, as needed, to make the full semantics of the question clear and to make the questions generalizable to multiple diseases where possible. Questions were indexed with metadata (structured and descriptive information) using a standard metadata framework to record such information as context, format, question asker and responder, and data standards information. Results At present, PRISM contains over 2,200 questions, with content of PRISM relevant to virtually all rare diseases. While the inclusion of disease-specific questions for thousands of rare disease organizations seeking to develop registries would present a challenge for traditional standards development organizations, the PRISM library could serve as a platform to liaison between rare disease communities and existing standardized controlled terminologies, item banks, and coding systems. Conclusions If widely used, PRISM will enable the re-use of questions across registries, reduce variation in registry data collection, and facilitate a bottom-up standardization of patient registries. Although it was initially developed to fulfill an urgent need in the rare disease community for shared resources, the PRISM library of patient-directed registry questions can be a valuable resource for registries in any disease – whether common or rare. Trial Registration N/A PMID:23611924
Generation of Ultrashort Pulses from Chromium - Forsterite Laser
NASA Astrophysics Data System (ADS)
Seas, Antonios
This thesis discusses the generation of ultrashort pulses from the chromium-doped forsterite laser, the various designs, construction and operation of forsterite laser systems capable of generating picosecond and femtosecond pulses in the near infrared. Various mode-locking techniques including synchronous optical pumping, active mode-locking, and self-mode-locking were successfully engineered and implemented. Active and synchronously pumped mode-locking using a three mirror, astigmatically compensated cavity design and a forsterite crystal with a figure of merit of 26 (FOM = alpha_{rm 1064nm} /alpha_{rm 1250nm }) generated pulses with FWHM of 49 and 260 ps, respectively. The tuning range of the mode-locked forsterite laser in both cases was determined to be in the order of 100 nm limited only by the dielectric coatings of the mirrors used in the cavity. The slope efficiency was measured to be 12.5% for synchronous pumping and 9.1% for active mode-locking. A four mirror astigmatically compensated cavity was found to be more appropriate for mode-locking. Active mode-locking using the four-mirror cavity generated pulses with FWHM of 31 ps. The pulsewidth was further reduced to 6 ps by using a forsterite crystal with a higher figure of merit (FOM = 39). Pulsewidth-bandwidth measurements indicated the presence of chirp in the output pulses. Numerical calculation of the phase characteristics of various optical materials indicated that a pair of prisms made of SF 14 optical glass can be used in the cavity in order to compensate for the chirp. The insertion of the prisms in the cavity resulted in a reduction of the pulsewidth from 6 ps down to 900 fs. Careful optimization of the laser cavity resulted in the generation of stable 90-fs pulses. Pulses as short as 60 fs were generated and self-mode-locked mode of operation using the Cr:forsterite laser was demonstrated for the first time. Pure self-mode-locking was next achieved generating 105-fs pulses tunable between 1230-1270 nm. Numerical calculations of the cubic phase characteristics of the prism pair used indicated that the pair of SF 14 prisms compensated for quadratic phase but introduced a large cubic phase term. Numerical evaluation of other optical glasses indicated that a pair of SFN 64 prisms can introduce the same quadratic phase as SF 14 prisms but introduce a smaller cubic phase. When the SF 14 prisms were replaced by SFN 64 prisms the pulsewidth was reduced to 50 fs. Great improvement was also observed in the stability of the self-mode-locked forsterite laser and in the ease of achieving mode-locking. Using the same experimental arrangement and a forsterite crystal with improved FOM the pulse width was reduced to 36 fs.
NASA Astrophysics Data System (ADS)
Cook, B.; Henstock, T.; McNeill, L. C.; Geersen, J.; Bull, J. M.
2013-12-01
The Central Sumatran Forearc exhibits along and across strike variations in morphology and deformation style; variations occur over distances of 10's to 100's of kilometres and are related to the varying oceanic basement topography and sediment input. We present a detailed interpretation of multi-channel seismic reflection (MCS) data offshore Central Sumatra to better characterise morphologic and structural variations; provide insight into fault development; relate structures to the varying input parameters; and identify any links to seismicity. The data were collected using a 5420 cu. in. gun array and recorded with a 192-channel, 2.4 km long streamer. Data coverage extends across strike from the deformation front to the outer forearc high with a few lines extending into the forearc basin; and along strike from 1.5οS to 3oN. In the southern part of our study area, from 1.5oS to 0.5oN, oceanic basement highs outcrop at the seafloor along the outer-arc high and the sediment section thickness varies from approximately 1.2 to 3.2 km at the trench. The accretionary prism is comprised of seaward-, landward- and mixed-vergence faults which apparently sole into the top of oceanic basement. Landward-vergent faults are concentrated at the deformation front near the subducting Wharton Fossil Ridge and seem to be associated with a relatively strong downgoing plate reflection. The larger accretionary prism structure is dominated by two relatively continuous, major fault-controlled structures that divide the prism into three strike-parallel belts. From 0.5oN to 2oN, the sediment section is approximately 2.3-4.3 km thick and we do not observe oceanic basement outcrops at the seafloor. Landward-vergent faults are less common and where present they are subordinate to relatively high-offset seaward-vergent faults at the deformation front. The larger prism structure has a convex profile which results from displacement on several major faults. North of 2oN, the sediment section at the trench is >4.5 km thick and a high-amplitude, negative polarity reflector is observed approximately 500 m above the oceanic basement. Landward-vergent faults are commonly observed at the deformation front. The larger accretionary prism structure transitions to the steep frontal prism and wide plateau geometry observed off Northern Sumatra. In the southern part of our study area, short wavelength variations in structure and plate boundary reflectivity, and the Batu Islands earthquake segment boundary are coincident with the subducting Wharton Fossil Ridge. Longer-wavelength changes in the overall prism structure observed across our study area are likely related to regional changes in sediment properties and thickness and may be linked to differing rupture characteristics.
ERIC Educational Resources Information Center
Hornberger, Breann
This paper presents an evaluation of the Peer Coaching Seminar Course offered through the Peer Coaching Rural Inservice Model (PRISM) project at the North Dakota Center for Persons with Disabilities. This online course was designed to help rural teachers learn both peer coaching and classroom management skills. Twenty first- or second-year…
USDA-ARS?s Scientific Manuscript database
Field trapping assays were conducted in 2009 and 2010 throughout western Michigan, USA, to evaluate lures for adult emerald ash borer, A. planipennis Fairmaire (Coleoptera: Buprestidae). Several ash tree volatiles were tested on purple prism traps in 2009, and a dark green prism trap in 2010. In 200...
Dielectric prisms would improve performance of quasi-optical microwave components
NASA Technical Reports Server (NTRS)
Carson, J. W.
1967-01-01
Properties of the Brewster angle and internal reflection in a dielectric prism are proposed as the basis of a new type of element for use in oversize waveguide in quasi-optical microwave components. Waveguide loss is reduced and precision broadband attenuators, phase shifters, and directional couplers can be constructed on the basis of the properties.
Introduction to Fourier Optics
ERIC Educational Resources Information Center
Huggins, Elisha
2007-01-01
Much like a physical prism, which displays the frequency components of a light wave, Fourier analysis can be thought of as a mathematical prism that can tell us what harmonics or frequency components are contained in a recording of a sound wave. We wrote the MacScope II program so that the user could not only see a plot of the harmonic amplitudes…
Experience with basal area estimation by prisms in lodgepole pine.
James M. Trappe
1957-01-01
Estimation of basal area by prisms offers intriguing possibilities for reducing time and effort in making stand inventories. Increased inventory efficiency is a particular need in stands that are relatively low in value due to small stems, predominance of low value species or heavy defect. In the Pacific Northwest, lodgepole pine characteristically forms dense low-...
"The Craft so Long to Lerne": Aspects of Time in Language Learning
ERIC Educational Resources Information Center
Oxford, Rebecca L.
2017-01-01
Time factors complexly, dynamically interact with each other and with other contextualized variables in language learning. The time-tied nature of language learning is captured in what I call the "time-prism," which is the central symbol of temporality in this paper. The facets of the prism discussed in this article are (1) language…
Simulator scene display evaluation device
NASA Technical Reports Server (NTRS)
Haines, R. F. (Inventor)
1986-01-01
An apparatus for aligning and calibrating scene displays in an aircraft simulator has a base on which all of the instruments for the aligning and calibrating are mounted. Laser directs beam at double right prism which is attached to pivoting support on base. The pivot point of the prism is located at the design eye point (DEP) of simulator during the aligning and calibrating. The objective lens in the base is movable on a track to follow the laser beam at different angles within the field of vision at the DEP. An eyepiece and a precision diopter are movable into a position behind the prism during the scene evaluation. A photometer or illuminometer is pivotable about the pivot into and out of position behind the eyepiece.
Stereoscopic optical viewing system
Tallman, C.S.
1986-05-02
An improved optical system which provides the operator with a stereoscopic viewing field and depth of vision, particularly suitable for use in various machines such as electron or laser beam welding and drilling machines. The system features two separate but independently controlled optical viewing assemblies from the eyepiece to a spot directly above the working surface. Each optical assembly comprises a combination of eye pieces, turning prisms, telephoto lenses for providing magnification, achromatic imaging relay lenses and final stage pentagonal turning prisms. Adjustment for variations in distance from the turning prisms to the workpiece, necessitated by varying part sizes and configurations and by the operator's visual accuity, is provided separately for each optical assembly by means of separate manual controls at the operator console or within easy reach of the operator.
NASA Astrophysics Data System (ADS)
Cole, William T. S.; Farrell, James D.; Sheikh, Akber A.; Yönder, Öezlem; Fellers, Raymond S.; Viant, Mark R.; Wales, David J.; Saykally, Richard J.
2018-03-01
Using diode laser vibration-rotation-tunneling spectroscopy near 15 Thz (500 cm-1), we have measured and assigned 142 transitions to three a-type librational subbands of the water hexamer-d12 prism. These subbands reveal dramatically enhanced (ca. 1000×) tunneling splittings relative to the ground state. This enhancement is in agreement with that observed for the water dimer, trimer, and pentamer in this same frequency region. The water prism tunneling motion has been predicted to potentially describe the motions of water in interfacial and confined environments; hence, the results presented here indicate that excitation of librational vibrations has a significant impact on the hydrogen bond dynamics in these macroscopic environments.
A fast image simulation algorithm for scanning transmission electron microscopy.
Ophus, Colin
2017-01-01
Image simulation for scanning transmission electron microscopy at atomic resolution for samples with realistic dimensions can require very large computation times using existing simulation algorithms. We present a new algorithm named PRISM that combines features of the two most commonly used algorithms, namely the Bloch wave and multislice methods. PRISM uses a Fourier interpolation factor f that has typical values of 4-20 for atomic resolution simulations. We show that in many cases PRISM can provide a speedup that scales with f 4 compared to multislice simulations, with a negligible loss of accuracy. We demonstrate the usefulness of this method with large-scale scanning transmission electron microscopy image simulations of a crystalline nanoparticle on an amorphous carbon substrate.
Inertial constraints on limb proprioception are independent of visual calibration.
Riley, M A; Turvey, M T
2001-04-01
When the coincidence of a limb's spatial axes and inertial eigenvectors is broken, haptic proprioception of the limb's position conforms to the eigenvectors. Additionally, when prisms break the coincidence between an arm's visual and actual positions, haptic proprioception is shifted toward the visual-spatial direction. In 3 experiments, variation of the arm's mass distribution was combined with prism adaptation to investigate the hypothesis that the proprioceptive effects of inertial and visual manipulations are additive. This hypothesis was supported across manipulations of plane of motion, body posture, proprioceptive target, and proprioceptive experience during prism adaptation. Haptic proprioception seems to depend on local, physical reference frames that are relative to the physical reference frames for the body's environmental position and orientation.
A fast image simulation algorithm for scanning transmission electron microscopy
Ophus, Colin
2017-05-10
Image simulation for scanning transmission electron microscopy at atomic resolution for samples with realistic dimensions can require very large computation times using existing simulation algorithms. Here, we present a new algorithm named PRISM that combines features of the two most commonly used algorithms, namely the Bloch wave and multislice methods. PRISM uses a Fourier interpolation factor f that has typical values of 4-20 for atomic resolution simulations. We show that in many cases PRISM can provide a speedup that scales with f 4 compared to multislice simulations, with a negligible loss of accuracy. We demonstrate the usefulness of this methodmore » with large-scale scanning transmission electron microscopy image simulations of a crystalline nanoparticle on an amorphous carbon substrate.« less
Stereoscopic optical viewing system
Tallman, Clifford S.
1987-01-01
An improved optical system which provides the operator a stereoscopic viewing field and depth of vision, particularly suitable for use in various machines such as electron or laser beam welding and drilling machines. The system features two separate but independently controlled optical viewing assemblies from the eyepiece to a spot directly above the working surface. Each optical assembly comprises a combination of eye pieces, turning prisms, telephoto lenses for providing magnification, achromatic imaging relay lenses and final stage pentagonal turning prisms. Adjustment for variations in distance from the turning prisms to the workpiece, necessitated by varying part sizes and configurations and by the operator's visual accuity, is provided separately for each optical assembly by means of separate manual controls at the operator console or within easy reach of the operator.
NASA Technical Reports Server (NTRS)
Lagowski, J.; Gatos, H. C.; Dabkowski, F. P.
1985-01-01
A novel partially confined configuration is proposed for the crystal growth of semiconductors from the melt, including those with volatile constituents. A triangular prism is employed to contain the growth melt. Due to surface tension, the melt will acquire a cylindrical-like shape and thus contact the prism along three parallel lines. The three empty spaces between the cylindrical melt and the edges of the prism will accommodate the expansion of the solidifying semiconductor, and in the case of semiconductor compounds with a volatile constituent, will permit the presence of the desired vapor phase in contact with the melt for controlling the melt stoichiometry. Theoretical and experimental evidence in support of this new type of confinement is presented.
Train integrity detection risk analysis based on PRISM
NASA Astrophysics Data System (ADS)
Wen, Yuan
2018-04-01
GNSS based Train Integrity Monitoring System (TIMS) is an effective and low-cost detection scheme for train integrity detection. However, as an external auxiliary system of CTCS, GNSS may be influenced by external environments, such as uncertainty of wireless communication channels, which may lead to the failure of communication and positioning. In order to guarantee the reliability and safety of train operation, a risk analysis method of train integrity detection based on PRISM is proposed in this article. First, we analyze the risk factors (in GNSS communication process and the on-board communication process) and model them. Then, we evaluate the performance of the model in PRISM based on the field data. Finally, we discuss how these risk factors influence the train integrity detection process.
Kondo, Takuya; Nomura, Kouji; Gemmei-Ide, Makoto; Kitano, Hiromi; Noguchi, Hidenori; Uosaki, Kohei; Saruwatari, Yoshiyuki
2014-01-01
A copolymer film composed of zwitterionic carboxymethylbetaine (CMB) and n-butyl methacrylate (BMA), Poly(CMB-r-BMA), was cast on a flat plane of an octadecyltrichlorosilane (ODS)-modified fused quartz prism with a semi-cylindrical shape. CH stretching of the polymer film and O-H stretching of water at the surface of the film were examined using the sum frequency generation (SFG) technique. The C-H stretching band of the cast film, indicating a gauche defect of the film, was affected by the contact medium including dry nitrogen, water vapor-saturated nitrogen and liquid water. In contrast, the C-H stretching of an octadecyl group introduced onto the quartz prism for stable attachment of the cast film was not significantly changed by the contact medium. The O-H stretching band indicated that water molecules at the surface of the Poly(CMB-r-BMA) film in contact with liquid water were not greatly oriented in comparison with those at the surfaces of a bare prism, an ODS SAM-modified prism, and a prism covered with a PolyBMA film or a copolymer film of BMA and methacrylic acid or 2-(dimethylamino)ethyl methacrylate. A similar small perturbation of the structure of water was previously observed in the vicinity of water-soluble zwitterionic polymers and zwitterionic copolymer films using Raman and attenuated total reflection infrared spectroscopies, respectively. A distinct effect of charge neutralization to diminish the perturbation of the structure of interfacial water around polymer materials was suggested. Copyright © 2013 Elsevier B.V. All rights reserved.
Correction of Single Frequency Altimeter Measurements for Ionosphere Delay
NASA Technical Reports Server (NTRS)
Schreiner, William S.; Markin, Robert E.; Born, George H.
1997-01-01
This study is a preliminary analysis of the accuracy of various ionosphere models to correct single frequency altimeter height measurements for Ionospheric path delay. In particular, research focused on adjusting empirical and parameterized ionosphere models in the parameterized real-time ionospheric specification model (PRISM) 1.2 using total electron content (TEC) data from the global positioning system (GPS). The types of GPS data used to adjust PRISM included GPS line-of-sight (LOS) TEC data mapped to the vertical, and a grid of GPS derived TEC data in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by IRI-90, a climatotogical model, were compared to TOPEX/Poseidon (T/P) TEC measurements from the dual-frequency altimeter for a number of T/P tracks. When adjusted with GPS LOS data, the PRISM empirical model predicted TEC over 24 1 h data sets for a given local time to with in a global error of 8.60 TECU rms during a midnight centered ionosphere and 9.74 TECU rms during a noon centered ionosphere. Using GPS derived sun-fixed TEC data, the PRISM parameterized model predicted TEC within an error of 8.47 TECU rms centered at midnight and 12.83 TECU rms centered at noon. From these best results, it is clear that the proposed requirement of 3-4 TECU global rms for TOPEX/Poseidon Follow-On will be very difficult to meet, even with a substantial increase in the number of GPS ground stations, with any realizable combination of the aforementioned models or data assimilation schemes.
Three timescales in prism adaptation.
Inoue, Masato; Uchimura, Motoaki; Karibe, Ayaka; O'Shea, Jacinta; Rossetti, Yves; Kitazawa, Shigeru
2015-01-01
It has been proposed that motor adaptation depends on at least two learning systems, one that learns fast but with poor retention and another that learns slowly but with better retention (Smith MA, Ghazizadeh A, Shadmehr R. PLoS Biol 4: e179, 2006). This two-state model has been shown to account for a range of behavior in the force field adaptation task. In the present study, we examined whether such a two-state model could also account for behavior arising from adaptation to a prismatic displacement of the visual field. We first confirmed that an "adaptation rebound," a critical prediction of the two-state model, occurred when visual feedback was deprived after an adaptation-extinction episode. We then examined the speed of decay of the prism aftereffect (without any visual feedback) after repetitions of 30, 150, and 500 trials of prism exposure. The speed of decay decreased with the number of exposure trials, a phenomenon that was best explained by assuming an "ultraslow" system, in addition to the fast and slow systems. Finally, we compared retention of aftereffects 24 h after 150 or 500 trials of exposure: retention was significantly greater after 500 than 150 trials. This difference in retention could not be explained by the two-state model but was well explained by the three-state model as arising from the difference in the amount of adaptation of the "ultraslow process." These results suggest that there are not only fast and slow systems but also an ultraslow learning system in prism adaptation that is activated by prolonged prism exposure of 150-500 trials. Copyright © 2015 the American Physiological Society.
IR Spectrometer Using 90-Degree Off-Axis Parabolic Mirrors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert M. Malone, Ian J. McKenna
2008-03-01
A gated spectrometer has been designed for real-time, pulsed infrared (IR) studies at the National Synchrotron Light Source at the Brookhaven National Laboratory. A pair of 90-degree, off-axis parabolic mirrors are used to relay the light from an entrance slit to an output recording camera. With an initial wavelength range of 1500–4500 nm required, gratings could not be used in the spectrometer because grating orders would overlap. A magnesium oxide prism, placed between these parabolic mirrors, serves as the dispersion element. The spectrometer is doubly telecentric. With proper choice of the air spacing between the prism and the second parabolicmore » mirror, any spectral region of interest within the InSb camera array’s sensitivity region can be recorded. The wavelengths leaving the second parabolic mirror are collimated, thereby relaxing the camera positioning tolerance. To set up the instrument, two different wavelength (visible) lasers are introduced at the entrance slit and made collinear with the optical axis via flip mirrors. After dispersion by the prism, these two laser beams are directed to tick marks located on the outside housing of the gated IR camera. This provides first-order wavelength calibration for the instrument. Light that is reflected off the front prism face is coupled into a high-speed detector to verify steady radiance during the gated spectral imaging. Alignment features include tick marks on the prism and parabolic mirrors. This instrument was designed to complement single-point pyrometry, which provides continuous time histories of a small collection of spots from shock-heated targets.« less
IR Spectrometer Using 90-degree Off-axis Parabolic Mirrors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert M. Malone, Richard, G. Hacking, Ian J. McKenna, and Daniel H. Dolan
2008-09-02
A gated spectrometer has been designed for real-time, pulsed infrared (IR) studies at the National Synchrotron Light ource at the Brookhaven National Laboratory. A pair of 90-degree, off-axis parabolic mirrors are used to relay the light from an entrance slit to an output IR recording camera. With an initial wavelength range of 1500–4500 nm required, gratings could not be used in the spectrometer because grating orders would overlap. A magnesium oxide prism, placed between these parabolic mirrors, serves as the dispersion element. The spectrometer is doubly telecentric. With proper choice of the air spacing between the prism and the secondmore » parabolic mirror, any spectral region of interest within the InSb camera array’s sensitivity region can be recorded. The wavelengths leaving the second parabolic mirror are collimated, thereby relaxing the camera positioning tolerance. To set up the instrument, two different wavelength (visible) lasers are introduced at the entrance slit and made collinear with the optical axis via flip mirrors. After dispersion by the prism, these two laser beams are directed to tick marks located on the outside housing of the gated IR camera. This provides first-order wavelength calibration for the instrument. Light that is reflected off the front prism face is coupled into a high-speed detector to verify steady radiance during the gated spectral imaging. Alignment features include tick marks on the prism and parabolic mirrors. This instrument was designed to complement singlepoint pyrometry, which provides continuous time histories of a small collection of spots from shock-heated targets.« less
NASA Astrophysics Data System (ADS)
Woo, Sungsoo; Kang, Sungsam; Yoon, Changhyeong; Choi, Wonshik
2016-03-01
With the advancement of 3D display technology, 3D imaging of macroscopic objects has drawn much attention as they provide the contents to display. The most widely used imaging methods include a depth camera, which measures time of flight for the depth discrimination, and various structured illumination techniques. However, these existing methods have poor depth resolution, which makes imaging complicated structures a difficult task. In order to resolve this issue, we propose an imaging system based upon low-coherence interferometry and off-axis digital holographic imaging. By using light source with coherence length of 200 micro, we achieved the depth resolution of 100 micro. In order to map the macroscopic objects with this high axial resolution, we installed a pair of prisms in the reference beam path for the long-range scanning of the optical path length. Specifically, one prism was fixed in position, and the other prism was mounted on a translation stage and translated in parallel to the first prism. Due to the multiple internal reflections between the two prisms, the overall path length was elongated by a factor of 50. In this way, we could cover a depth range more than 1 meter. In addition, we employed multiple speckle illuminations and incoherent averaging of the acquired holographic images for reducing the specular reflections from the target surface. Using this newly developed system, we performed imaging targets with multiple different layers and demonstrated imaging targets hidden behind the scattering layers. The method was also applied to imaging targets located around the corner.
Prisms for pain. Can visuo-motor rehabilitation strategies alleviate chronic pain?
Torta, DM; Legrain, V; Rossetti, Y; Mouraux, A
2017-01-01
Background and aims Prism adaptation (PA) is a non-invasive procedure in which participants perform a visuo-motor pointing task while wearing prism goggles inducing a lateral displacement of the visual field and a mismatch between the seen and felt position of the pointing hand. PA is thought to induce a reorganization of sensorimotor coordination, and has been used successfully to rehabilitate neglect following right-hemisphere lesions. Because studies have shown that complex regional pain syndrome (CRPS) is associated with neglect-like symptoms, it was proposed that PA could be used to alleviate pain in these patients. Database A search for peer-reviewed articles on neglect-like symptoms in CRPS and on the use of prisms in CRPS was conducted using the PubMed database. Results There is still no agreement as to whether CRPS patients really present neglect symptoms and, if they do, what it is that they neglect. Furthermore, there is insufficient data to determine whether PA exerts an effect on CRPS symptoms. Finally, it remains unknown whether neglect can be observed in other types of lateralized pain, or whether PA could be useful for these patients. Conclusion By highlighting open issues, our review provides guidelines for future studies on the use of prisms in pain. The assessment of neglect in patients with CRPS as well as other types of lateralized chronic pain should be characterized using a combination of neuropsychological methods assessing the multiple aspects of neglect in a more refined manner. In addition, further studies should investigate the mechanisms through which PA may modulate pain. PMID:26095341
Kinematics and Dynamics of the Makran Subduction Zone
NASA Astrophysics Data System (ADS)
Penney, C.; Tavakoli, F.; Sobouti, F.; Copley, A.; Priestley, K. F.; Jackson, J. A.
2016-12-01
The Makran subduction zone, along the southern coasts of Iran and Pakistan, hosts the world's largest exposed accretionary prism. In contrast to the circum-Pacific subduction zones, the Makran has not been extensively studied, with seismic data collected in the offshore region presenting only a time-integrated picture of the deformation. We investigate spatio-temporal variations in the deformation of the accretionary prism and the insights these offer into subduction zone driving forces and megathrust rheology. We combine seismology, geodesy and field observations to study the 2013 Mw 6.1 Minab earthquake, which occurred at the western end of the accretionary prism. We find that the earthquake was a left-lateral rupture on an ENE-WSW plane, approximately perpendicular to the previously mapped faults in the region. The causative fault of the Minab earthquake is one of a series of left-lateral faults in the region which accommodate a velocity field equivalent to right-lateral shear on N-S planes by rotating clockwise about vertical axes. Another recent strike-slip event within the Makran accretionary wedge was the 2013 Mw 7.7 Balochistan earthquake, which occurred on a fault optimally oriented to accommodate the regional compression by thrusting. The dominance of strike-slip faulting within the onshore prism, on faults perpendicular to the regional compression, suggests that the prism may have reached the maximum elevation which the megathrust can support, with the compressional forces which dominated in the early stages of the collision now balanced by gravitational forces. This observation allows us to estimate the mean shear stress on the megathrust interface and its effective coefficient of friction.
Measurement of separator contact forces in ball bearings using a derotation prism
NASA Technical Reports Server (NTRS)
Nypan, L. J.
1978-01-01
A derotation prism was used to produce a stationary image of balls deflecting a portion of the separator. Ball to cage contact forces in a 110 mm bearing at speeds to 12,000 rpm were found to be 25 N (five lb) maximum. Inner race land contact force was found to vary up to 20 N (four lb).
Assessing forest mortality patterns using climate and FIA data at multiple scales
Michael K. Crosby; Zhaofei Fan; Xingang Fan; Theodor D. Leininger; Martin A. Spetich
2012-01-01
Forest Inventory and Analysis (FIA) and PRISM climate data from 1991-2000 were obtained for 10 states in the southeastern United States. Mortality was calculated for each plot, and annual values for precipitation and maximum and minimum temperature were extracted from the PRISM data. Data were then stratified by upland/bottomland for red oak species, and classification...
ERIC Educational Resources Information Center
Karaibryamov, Samet; Tsareva, Bistra; Zlatanov, Boyan
2012-01-01
This work acquaints with the program Sam for interactive computer training of students on the theme "Mutual intersecting of pyramids and prisms in axonometry". The program containing three modules--teacher, student and autopilot--allows for briefest time to teach and study the whole variety of the tasks on this theme. A classification of…
ERIC Educational Resources Information Center
Tekin-Sitrava, Reyhan; Isiksal-Bostan, Mine
2018-01-01
This study investigated middle school teachers' knowledge of students' misconceptions and the sources of these misconceptions related to the volume of prisms. This case study investigated four middle school teachers who taught 8th grade students in Ankara (Turkey). Based on the analysis of the data, two misconceptions related to the volume of…
NASA Astrophysics Data System (ADS)
Remes, Z.; Kozak, H.; Rezek, B.; Ukraintsev, E.; Babchenko, O.; Kromka, A.; Girard, H. A.; Arnault, J.-C.; Bergonzo, P.
2013-04-01
Linear antenna microwave chemical vapor deposition process was used to homogeneously coat a 7 cm long silicon prism by 85 nm thin nanocrystalline diamond (NCD) layer. To show the advantages of the NCD-coated prism for attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) of nanoparticles, we apply diamond nanoparticles (DNPs) of 5 nm nominal size with various surface modifications by a drop-casting of their methanol dispersions. ATR-FTIR spectra of as-received, air-annealed, plasma-oxidized, and plasma-hydrogenated DNPs were measured in the 4000-1500 cm-1 spectral range. The spectra show high spectral resolution, high sensitivity to specific DNP surface moieties, and repeatability. The NCD coating provides mechanical protection against scratching and chemical stability of the surface. Moreover, unlike on bare Si surface, NCD hydrophilic properties enable optically homogeneous coverage by DNPs with some aggregation on submicron scale as evidenced by scanning electron microscopy and atomic force microscopy. Compared to transmission FTIR regime with KBr pellets, direct and uniform deposition of DNPs on NCD-ATR prism significantly simplifies and speeds up the analysis (from days to minutes). We discuss prospects for in situ monitoring of surface modifications and molecular grafting.
Hill, R.J.; Schenk, C.J.
2005-01-01
Petroleum produced from the Barbados accretionary prism (at Woodbourne Field on Barbados) is interpreted as generated from Cretaceous marine shale deposited under normal salinity and dysoxic conditions rather than from a Tertiary source rock as previously proposed. Barbados oils correlate with some oils from eastern Venezuela and Trinidad that are positively correlated to extracts from Upper Cretaceous La Luna-like source rocks. Three distinct groups of Barbados oils are recognized based on thermal maturity, suggesting petroleum generation occurred at multiple levels within the Barbados accretionary prism. Biodegradation is the most significant process affecting Barbados oils resulting in increased sulfur content and decreased API gravity. Barbados gases are interpreted as thermogenic, having been co-generated with oil, and show mixing with biogenic gas is limited. Gas biodegradation occurred in two samples collected from shallow reservoirs at the Woodbourne Field. The presence of Cretaceous source rocks within the Barbados accretionary prism suggests that greater petroleum potential exists regionally, and perhaps further southeast along the passive margin of South America. Likewise, confirmation of a Cretaceous source rock indicates petroleum potential exists within the Barbados accretionary prism in reservoirs that are deeper than those from Woodbourne Field.
Wong, M S; Mak, A F T; Luk, K D K; Evans, J H; Brown, B
2002-08-01
This is a preliminary investigation to detect the body sway and postural changes of patients with AIS under different spatial images. Two pairs of low-power prismatic eye lenses (Fresnel prisms) with 5 dioptre and 10 dioptre were used. In the experiment, the apices of the prisms were orientated randomly at every 22.5 degrees from 0 degrees to 360 degrees to test changes. Four patients with mean age of 11 and Cobb's angle of 30 degrees were recruited and the results showed that the low-power prisms at specific orientations (157.5 degrees and 180 degrees) could cause positive postural changes (2.1 degrees-2.7 degrees reduction of angle of trunk mis-alignment) measured by 3-D motion analysis. This might be used for controlling their scoliotic curves by induced visual bio-feedback. Apart from this laboratory test, a longitudinal study is necessary to investigate the long-term effect of the prisms at different powers and orientations (under both static and dynamic situations) on the patient's posture, spinal muscular activities, vision, eye-hand coordination, psychological state and other daily activities before it becomes an alternative management of AIS.
NASA Astrophysics Data System (ADS)
Harford, Steven T.; Gutierrez, Homero; Newman, Michael; Pierce, Robert; Quakenbush, Tim; Wallace, John; Bornstein, Michael
2014-03-01
Ball Aerospace & Technologies Corp. (BATC) has developed a Risley Beam Pointer (RBP) mechanism capable of agile slewing, accurate pointing and high bandwidth. The RBP is comprised of two wedged prisms that offer a wide Field of Regard (FOR) and may be manufactured and operated with diffraction limited optical quality. The tightly packaged mechanism is capable of steering a 4 inch beam over a 60° half angle cone with better than 60 μrad precision. Absolute accuracy of the beam steering is better than 1 mrad. The conformal nature of the RBP makes it an ideal mechanism for use on low altitude aircraft and unmanned aerial vehicles. Unique aspects of the opto-mechanical design include i) thermal compliance to maintain bearing preload and optical figure over a wide temperature range; and ii) packaging of a remote infrared sensor that periodically reports the temperature of both prisms for accurate determination of the index of refraction. The pointing control system operates each prism independently and employs an inner rate loop nested within an outer position loop. Mathematics for the transformation between line-of-sight coordinates and prism rotation are hosted on a 200 MHz microcontroller with just 516 KB of RAM.
Changes in prescribed doses for the Seattle neutron therapy system
NASA Astrophysics Data System (ADS)
Popescu, A.
2008-06-01
From the beginning of the neutron therapy program at the University of Washington Medical Center, the neutron dose distribution in tissue has been calculated using an in-house treatment planning system called PRISM. In order to increase the accuracy of the absorbed dose calculations, two main improvements were made to the PRISM treatment planning system: (a) the algorithm was changed by the addition of an analytical expression of the central axis wedge factor dependence with field size and depth developed at UWMC. Older versions of the treatment-planning algorithm used a constant central axis wedge factor; (b) a complete newly commissioned set of measured data was introduced in the latest version of PRISM. The new version of the PRISM algorithm allowed for the use of the wedge profiles measured at different depths instead of one wedge profile measured at one depth. The comparison of the absorbed dose calculations using the old and the improved algorithm showed discrepancies mainly due to the missing central axis wedge factor dependence with field size and depth and due to the absence of the wedge profiles at depths different from 10 cm. This study concludes that the previously reported prescribed doses for neutron therapy should be changed.
Reyes, Maria M; Schneekloth, Terry D; Hitschfeld, Mario J; Geske, Jennifer R; Atkinson, David L; Karpyak, Victor M
2016-05-02
The objective was to assess the clinical utility of the Adult ADHD Self-Report Scale (ASRS-v1.1) in identifying ADHD in alcoholics using the Psychiatric Research Interview for Substance and Mental Disorders (PRISM) as the diagnostic "gold standard." We performed a secondary analysis of data from 379 treatment-seeking alcoholics who completed the ASRS-v1.1 and the ADHD module of the PRISM. Data analysis included descriptive statistics. The prevalence of ADHD was 7.7% (95% CI = [5.4, 10.8]). The positive predictive value (PPV) of the ASRS-v1.1 was 18.1% (95% CI = [12.4, 25.7]) and the negative predictive value (NPV) was 97.6% (95% CI = [94.9, 98.9]). The ASRS-v1.1 demonstrated a sensitivity of 79.3% (95% CI = [61.6, 90.2]) and a specificity of 70.3% (95% CI = [65.3, 74.8]). The ASRS-v1.1 demonstrated acceptable sensitivity and specificity in a sample of treatment-seeking alcoholics when compared with the PRISM as the reference standard for ADHD diagnosis. © The Author(s) 2016.
High-precision angle sensor based on a Köster’s prism with absolute zero-point
NASA Astrophysics Data System (ADS)
Ullmann, V.; Oertel, E.; Manske, E.
2018-06-01
In this publication, a novel approach will be presented to use a compact white-light interferometer based on a Köster’s prism for angle measurements. Experiments show that the resolution of this angle interferometer is in the range of a commercial digital autocollimator, with a focal length of f = 300 mm, but with clearly reduced signal noise and without overshoot artifacts in the signal caused by digital filters. The angle detection of the reference mirror in the Köster’s interferometer is based on analysing the rotation angle of the fringe pattern, which is projected on a CMOS-matrix. The fringe pattern is generated by two displaced spherical wave fronts coming from one fiber-coupled white-light source and getting divided into a reference and a measurement beam by the Köster’s prism. The displacement correlates with the reference angle mirror in one linear direction and with the angle aberrations of the prism in the other orthogonal direction on the CMOS sensor. We will present the experimental and optical setup, the method and algorithms for the image-to-angle processing as well as the experimental results obtained in calibration and long-term measurements.
Optical design of infrared pyramid wavefront sensor for the MMT
NASA Astrophysics Data System (ADS)
Chen, Shaojie; Sivanandam, Suresh; Liu, Siqi; Veran, Jean-Pierre; Hinz, Phil; Mieda, Etsuko; Hardy, Tim; Lardiere, Olivier
2017-09-01
We report the optical design of an infrared (0.85-1.8 μm) pyramid wavefront sensor (IRPWFS) that is designed for the 6.5m MMT on telescope adaptive optics system using the latest developments in low-noise infrared avalanche photodiode arrays. The comparison between the pyramid and the double-roof prism based wavefront sensors and the evaluation of their micro pupils' quality are presented. According to our analysis, the use of two double-roof prisms with achromatic materials produces the competitive performance when compared to the traditional pyramid prism, which is difficult to manufacture. The final micro pupils on the image plane have the residual errors of pupil position, chromatism, and distortion within 1/10 pixel over the 2×2 arcsecond field of view, which meet the original design goals.
Characteristic analysis of a polarization output coupling Porro prism resonator
NASA Astrophysics Data System (ADS)
Yang, Hailong; Meng, Junqing; Chen, Weibiao
2015-02-01
An Electro-optical Q-switched Nd:YAG slab laser with a crossed misalignment Porro prism resonator for space applications has been theoretically and experimentally investigated. The phase shift induced by the combination of different wave plates and Porro prism azimuth angles have been studied for creating high loss condition prior to Q-switching. The relationship of the effective output coupling reflectivity and the employed Q-switch driving voltage is explored by using Jones matrix optics. In the experiment, the maximum output pulse energy of 93 mJ with 14-ns pulse duration is obtained at the repetition rate of 20 Hz and the optical-to-optical conversion efficiency is 16.8%. The beam quality factors are M 2 x = 2.5 and M 2y = 2.2, respectively.
Hexagonal Nanopyramidal Prisms of Nearly Intrinsic InN on Patterned GaN Nanowire Arrays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Golam Sarwar, A. T. M.; Leung, Benjamin; Wang, George T.
By using multiple growth steps that separate the nucleation and growth processes, we show that nearly intrinsic InN single nanocrystals of high optical quality can be formed on patterned GaN nanowire arrays by molecular beam epitaxy. The InN nanostructures form into well-defined hexagonal prisms with pyramidal tops. Micro-photoluminescence (μ-PL) is carried out at low temperature (LT: 28.2 K) and room temperature (RT: 285 K) to gauge the relative material quality of the InN nanostructures. Nanopyramidal prisms grown using a three-step growth method are found to show superior quantum efficiency. In conclusion, excitation and temperature dependent μ-PL demonstrates the very highmore » quality and nearly intrinsic nature of the ordered InN nanostructure arrays.« less
Hexagonal Nanopyramidal Prisms of Nearly Intrinsic InN on Patterned GaN Nanowire Arrays
Golam Sarwar, A. T. M.; Leung, Benjamin; Wang, George T.; ...
2018-01-04
By using multiple growth steps that separate the nucleation and growth processes, we show that nearly intrinsic InN single nanocrystals of high optical quality can be formed on patterned GaN nanowire arrays by molecular beam epitaxy. The InN nanostructures form into well-defined hexagonal prisms with pyramidal tops. Micro-photoluminescence (μ-PL) is carried out at low temperature (LT: 28.2 K) and room temperature (RT: 285 K) to gauge the relative material quality of the InN nanostructures. Nanopyramidal prisms grown using a three-step growth method are found to show superior quantum efficiency. In conclusion, excitation and temperature dependent μ-PL demonstrates the very highmore » quality and nearly intrinsic nature of the ordered InN nanostructure arrays.« less
Mid-Pliocene planktic foraminifer assemblage of the North Atlantic Ocean
Dowsett, H.J.; Robinson, M.M.
2007-01-01
The US Geological Survey Pliocene Research, Interpretation and Synoptic Mapping (PRISM) North Atlantic faunal data set provides a unique, temporally constrained perspective to document and evaluate the quantitative geographic distribution of key mid-Pliocene taxa. Planktic foraminifer census data from within the PRISM time slab (3.29 to 2.97 Ma) at thirteen sites in the North Atlantic Ocean have been analyzed. We have compiled Scanning Electron Micrographs for an atlas of mid-Pliocene assemblages from the North Atlantic with descriptions of each taxon to document the taxonomic concepts that accompany the PRISM data. In mid-Pliocene assemblages, the geographic distributions of extant taxa are similar to their present day distributions, although some are extended to the north. We use the distribution of extinct taxa to assess previous assumptions regarding environmental preferences.
BIOMECHANICS. Why the seahorse tail is square.
Porter, Michael M; Adriaens, Dominique; Hatton, Ross L; Meyers, Marc A; McKittrick, Joanna
2015-07-03
Whereas the predominant shapes of most animal tails are cylindrical, seahorse tails are square prisms. Seahorses use their tails as flexible grasping appendages, in spite of a rigid bony armor that fully encases their bodies. We explore the mechanics of two three-dimensional-printed models that mimic either the natural (square prism) or hypothetical (cylindrical) architecture of a seahorse tail to uncover whether or not the square geometry provides any functional advantages. Our results show that the square prism is more resilient when crushed and provides a mechanism for preserving articulatory organization upon extensive bending and twisting, as compared with its cylindrical counterpart. Thus, the square architecture is better than the circular one in the context of two integrated functions: grasping ability and crushing resistance. Copyright © 2015, American Association for the Advancement of Science.
NASA Astrophysics Data System (ADS)
Braaten, D. A.; Holvoet, J. F.; Gogineni, S.
2003-12-01
The Radar Systems and Remote Sensing Laboratory at the University of Kansas (KU) has implemented extensive outreach activities focusing on Polar Regions as part of the Polar Radar for Ice Sheet Measurements (PRISM) project. The PRISM project is developing advanced intelligent remote sensing technology that involves radar systems, an autonomous rover, and communications systems to measure detailed ice sheet characteristics, and to determine bed conditions (frozen or wet) below active ice sheets in both Greenland and Antarctica. These measurements will provide a better understanding of the response of polar ice sheets to global climate change and the resulting impact the ice sheets will have on sea level rise. Many of the research and technological development aspects of the PRISM project, such as robotics, radar systems, climate change and exploration of harsh environments, can kindle an excitement and interest in students about science and technology. These topics form the core of our K-12 education and training outreach initiatives, which are designed to capture the imagination of young students, and prompt them to consider an educational path that will lead them to scientific or engineering careers. The K-12 PRISM outreach initiatives are being developed and implemented in a collaboration with the Advanced Learning Technology Program (ALTec) of the High Plains Regional Technology in Education Consortium (HPR*TEC). ALTec is associated with the KU School of Education, and is a well-established educational research center that develops and hosts web tools to enable teachers nationwide to network, collaborate, and share resources with other teachers. An example of an innovative and successful web interface developed by ALTec is called TrackStar. Teachers can use TrackStar over the Web to develop interactive, resource-based lessons (called tracks) on-line for their students. Once developed, tracks are added to the TrackStar database and can be accessed and modified (if necessary) by teachers everywhere. The PRISM project has added a search engine for polar related tracks, and has developed numerous new tracks on robotics, polar exploration, and climate change under the guidance of a K-12 teacher advisory group. The PRISM project is also developing and hosting several other web-based lesson design tools and resources for K-12 educators and students on the PRISM project web page (http://www.ku-prism.org). These tools and resources include: i) "Polar Scientists and Explorers, Past and Present" covering the travels and/or unknown fate of polar explorers and scientists; ii) "Polar News" providing links to current news articles related to polar regions; iii) "Letter of Global Concern", which is a tool to help students draft a letter to a politician, government official, or business leader; iv) "Graphic Sleuth", which is an online utility that allows teachers to make lessons for student use; v) "Bears on Ice" for students in grades K - 6 that can follow the adventures of two stuffed bears that travel with scientists into polar regions; and vi) "K-12 Polar Resources," which provides teachers with images, information, TrackStar lessons, and a search engine designed to identify polar related lessons. In our presentation, we will describe and show examples of these tools and resources, and provide an assessment of their popularity with teachers nationwide.
Rowe, F J; Conroy, E J; Bedson, E; Cwiklinski, E; Drummond, A; García-Fiñana, M; Howard, C; Pollock, A; Shipman, T; Dodridge, C; MacIntosh, C; Johnson, S; Noonan, C; Barton, G; Sackley, C
2017-10-01
Pilot trial to compare prism therapy and visual search training, for homonymous hemianopia, to standard care (information only). Prospective, multicentre, parallel, single-blind, three-arm RCT across fifteen UK acute stroke units. Stroke survivors with homonymous hemianopia. Arm a (Fresnel prisms) for minimum 2 hours, 5 days per week over 6 weeks. Arm b (visual search training) for minimum 30 minutes, 5 days per week over 6 weeks. Arm c (standard care-information only). Adult stroke survivors (>18 years), stable hemianopia, visual acuity better than 0.5 logMAR, refractive error within ±5 dioptres, ability to read/understand English and provide consent. Primary outcomes were change in visual field area from baseline to 26 weeks and calculation of sample size for a definitive trial. Secondary measures included Rivermead Mobility Index, Visual Function Questionnaire 25/10, Nottingham Extended Activities of Daily Living, Euro Qual, Short Form-12 questionnaires and Radner reading ability. Measures were post-randomization at baseline and 6, 12 and 26 weeks. Randomization block lists stratified by site and partial/complete hemianopia. Allocations disclosed to patients. Primary outcome assessor blind to treatment allocation. Eighty-seven patients were recruited: 27-Fresnel prisms, 30-visual search training and 30-standard care; 69% male; mean age 69 years (SD 12). At 26 weeks, full results for 24, 24 and 22 patients, respectively, were compared to baseline. Sample size calculation for a definitive trial determined as 269 participants per arm for a 200 degree 2 visual field area change at 90% power. Non-significant relative change in area of visual field was 5%, 8% and 3.5%, respectively, for the three groups. Visual Function Questionnaire responses improved significantly from baseline to 26 weeks with visual search training (60 [SD 19] to 68.4 [SD 20]) compared to Fresnel prisms (68.5 [SD 16.4] to 68.2 [18.4]: 7% difference) and standard care (63.7 [SD 19.4] to 59.8 [SD 22.7]: 10% difference), P=.05. Related adverse events were common with Fresnel prisms (69.2%; typically headaches). No significant change occurred for area of visual field area across arms over follow-up. Visual search training had significant improvement in vision-related quality of life. Prism therapy produced adverse events in 69%. Visual search training results warrant further investigation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
McNeill, L.; Moore, J. C.; Yamada, Y.; Chang, C.; Tobin, H.; Kinoshita, M.; Gulick, S.; Moore, G.; Iodp Exp. 314/315/316 Science Party, &
2008-12-01
Borehole breakouts are commonly observed in borehole images shortly after drilling of continental margin sites. This study aims to compile and compare these results to determine what in situ shallow stress measurements can tell us about the larger scale tectonic regime. Recent Logging While Drilling resistivity images across the Kumano transect of the Nankai subduction zone, during Expedition 314, Stage 1 of the IODP NanTroSEIZE project, add to this dataset. Expedition 314 site data within the prism (C0001, C0004, C0006, including the megasplay fault system which may overlie the seismogenic updip limit) suggest maximum compressive stress (SHmax) is perpendicular to the margin (not parallel to the convergence vector) but is rotated through 90° at the forearc basin site (C0002). These results may point to changes in stress state of the shallow forearc from east to west: compression in the aseismic active prism (with evidence of strain partitioning of oblique convergence); and extension above the updip seismogenic zone suggesting focus of plate coupling at the plate boundary and not in the shallow forearc. Further south, ODP Leg 196 drilled the prism toe (808) with breakouts indicating SHmax parallel to the convergence vector, in contrast to Exp. 314 results. The stress state in the shallow prism at Site 808 may be affected by nearby seamount subduction or may represent differences in strain partitioning. On the Cascadia margin, two drilling legs have collected LWD borehole images (Leg 204 and Exp. 311). Leg 204 drilled 3 sites at hydrate ridge in the C Cascadia outer prism with breakout orientations variable between closely spaced sites. Prism fold axes are parallel to the margin so we might expect SHmax perpendicular to the margin as in Exp. 314. Deviations from this orientation may reflect local and surface effects (Goldberg and Janik, 2006). Exp. 311, N Cascadia, drilled 5 sites across the prism with breakouts in LWD images. Subduction is not oblique here, in contrast to the other sites discussed, and most sites indicate SHmax almost parallel to convergence and normal to major fold axes. In one case, the in situ stress orientation is also compatible with shallow normal faulting from seismic data. Site 1325, in a slope basin, deviates from this orientation and may reflect local processes. Borehole breakouts within the shallow forearc of convergent margins are often in agreement with other indications of regional tectonic stress and may be indicative of processes at depth. Deviations may represent local stresses due to gravitational processes.
The Portable Remote Imaging Spectrometer (PRISM) Coastal Ocean Sensor
NASA Technical Reports Server (NTRS)
Mouroulis, Pantazis; VanGorp, Byron E.; Green, Robert O.; Eastwppd, Michael; Wilson, Daniel W.; Richardson, Brandon; Dierssen, Heidi
2012-01-01
PRISM is an airborne pushbroom imaging spectrometer intended to address the needs of airborne coastal ocean science research. Its critical characteristics are high throughput and signal-to-noise ratio, high uniformity of response to reduce spectral artifacts, and low polarization sensitivity. We give a brief overview of the instrument and results from laboratory calibration measurements regarding the spatial, spectral, radiometric and polarization characteristics.
Optical Materials Characterization, Final Technical Report February 1, 1978-September 30, 1978
1979-02-01
FIGURES PAGE Figure 1. (a) Schematic of spectrometer used for visible region refractometry . (b) Schematic of spectrometer used for non-,visible...region refractometry . Symbols: A = source, B = divided circle, C = prism table, D = collimator, E = telescope, F = collimating mirror, G = movable... refractometry . (b) Schematic of spectrometer used for non- visible region refractometry . Symbols: A = source, B = divided circle, C = prism table